Suprema BEP2 OD User Manual

www.supremainc.com
INSTALLATION GUIDE
BioEntry P2
English
Version 1.00
EN 101.00.BEP2 V1.00A
Contents
Safety instructions ............................................................................................ 3
Introduction ...................................................................................................... 5
Components ................................................................................................................................................... 5
Name and function of each part ............................................................................................................... 6
Cables and connectors ...................................................................................................................................................... 7
How to enroll a fingerprint ........................................................................................................................ 9
Selecting a finger for fingerprint input ........................................................................................................................ 9
Fingerprint enroll method ................................................................................................................................................ 9
Installation ..................................................................................................... 10
Fixing the bracket and the product ........................................................................................................ 10
Power supply connection ........................................................................................................................... 12
Network connection .................................................................................................................................... 12
TCP/IP ..................................................................................................................................................................................12
TTL input connection ................................................................................................................................. 13
Relay connection ......................................................................................................................................... 14
Fail Safe Lock ....................................................................................................................................................................14
Fail Secure Lock ................................................................................................................................................................14
Automatic door connection ............................................................................................................................................15
Connecting as a standalone ...................................................................................................................... 16
Connecting to Secure I/O 2 ...................................................................................................................... 17
Wiegand connection ................................................................................................................................... 18
Resetting Network Settings ......................................................................................................................... 18
Restoring the Factory Defaults .................................................................................................................... 18
Product specifications .................................................................................. 19
Dimensions ................................................................................................................................................... 20
FCC compliance information ...................................................................... 21
Appendices ..................................................................................................... 22
Disclaimers ................................................................................................................................................... 22
Copyright notice .......................................................................................................................................... 22
Open Source License .................................................................................................................................... 22
GNU General Public License ..............................................................................................................................................22
GNU Lesser General Public License ..................................................................................................................................28
OpenSSL License ................................................................................................................................................................29
Original SSLeay License .....................................................................................................................................................30

Safety instructions

Safety instructions
Observe the following instructions to use the product safely and prevent any risk of injury or property damage.
Warning
Noncompliance of instructions could lead to serious injury or death.
Installation
Do not install the product in a place with direct sunlight, moisture, dust, or soot.
A fire or electric shock may occur.
Do not install the product in a place with heat from an electric heater.
A fire or electric shock may occur due to overheating.
Install the product in a dry place.
• Otherwise, a product damage or electric shock may occur due to moisture.
Install the product in a place with no electromagnetic interference.
• Otherwise, a product damage or electric shock may occur.
The user should not install or repair the product independently.
• A fire, electric shock, or personal injury may occur.
If the product has been damaged due to independent installation or repair of the product by the user, free A/S service will not be
provided.
Operation
Do not allow liquids such as water, beverages, or chemicals get into the product.
A fire, electric shock, or product damage may occur.
Caution
Noncompliance of instructions could lead to minor injury or product damage.
Installation
Do not install the power supply cable in a place where people pass by.
• Product damage or physical injury may occur.
Do not install the product near a highly magnetic object such as a magnet, TV, (especially CRT) monitor, or speaker.
• A product failure may occur.
If installing the product outside where the product is completely exposed, it is recommended to install the product together with the enclosure.
Use a separate power supply for Secure I/O 2, electric lock and BioEntry P2 respectively.
If connecting and using the power supply to these devices together, the devices may malfunction.
Keep the minimum separation distances between the devices when install multiple devices.
Otherwise, RF performance is affect to the other device, the devices may not operate normally.
3
Safety instructions
Operation
Do not drop the product or apply an impact to the product.
• A product failure may occur.
Be careful not to contaminate or damage the fingerprint contact unit with a dirty hand or foreign substances.
Deterioration in fingerprint authentication performance and a product failure may occur.
When cleaning the product, wipe the product with a soft and dry cloth and no water, benzene or alcohol.
• Otherwise, a product failure may occur.
4

Introduction

Note
BioEntry P2
Wall bracket
PVC anchor
Fixing screw
Diode
120 Ω resistor
Drilling template
Quick guide
Ferrite core
Connection cable
EA, 4 pins 4

Components

Introduction
(2 EA)
(2 pins 1 EA, 3 pins 1
(1 EA)
(2 EA)
(1 EA)
(1 EA)
Components may vary according to the installation environment.
5

Name and function of each part

Fingerprint
TTL Input (4 pins)
RF card
RS-485 (4 pins)
Relay (3 pins)
Wiegand Input/Output (4 pins)
Ethernet (4 pins)
Power supply (2 pins)
LED lamp
Introduction
authenticatio unit
authentication unit
Name Description
LED lamp
RF card authentication unit
Fingerprint authentication unit
Power supply (2 pins)
Relay (3 pins)
Ethernet (4 pins) Connect the Ethernet cable.
RS-485 (4 pins)
TTL Input (4 pins) Connect the TTL input cable.
Wiegand input/output (4 pins)
Indicates the operational status of the product with the color of the LED lamp.
Reads RF cards for entering and exiting.
Reads fingerprints placed on it for entering and exiting.
Connect the power supply cable.
Connect the relay cable.
Connect the RS-485 cable.
Connect the Wiegand input and output cable.
6

Cables and connectors

1
PWR +VDC
Red (white stripe)
2
PWR GND
Black (white stripe)
1
RLY NO
White
2
RLY COM
Blue
3
RLY NC
Orange
1
485 TRXP
Blue
2
485 TRXN
Yellow
3
485 GND
Black
4
SH GND
Gray
1
TTL IN0
Red
2
TTL IN1
Yellow
3
TTL GND
Black
4
SH GND
Gray
1
WG D0
Green
2
WG D1
White
3
WG GND
Black
4
SH GND
Gray
Power supply
Pin Name Color
Relay
Pin Name Color
RS-485
Introduction
Pin Name Color
TTL input
Pin Name Color
Wiegand input and output
Pin Name Color
7
Ethernet
1
ENET RXN
Yellow
2
ENET RXP
Green
3
ENET TXN
Red
4
ENET TXP
Black
Pin Name Color
Introduction
8
Introduction
1
Place the finger with the fingerprint to be registered on the fingerprint authentication unit and press the finger gently for better authentication.
2
After a beep sounds, scan the fingerprint of the registered finger again (scan the fingerprint of a finger to be registered t
Note

How to enroll a fingerprint

In order to improve the fingerprint authentication rate, register the fingerprint correctly. BioEntry P2 can recognize a fingerprint even if the angle and position of a user's fingerprint input change. If you register the fingerprint with attention to the following matters, the authentication rate can be improved.

Selecting a finger for fingerprint input

In preparation for the case that the fingerprint of a specific finger cannot be used, for example if the user is lifting a load with one hand or a finger gets hurt, up to 10 fingerprints for each user can be registered.
In the case of a user whose fingerprint cannot be recognized well, the authentication rate can be improved by enrolling the same finger twice repeatedly.
• If a finger has a cut or the fingerprint is blurry, select another finger for the fingerprint.
It is recommended to use the index finger or the middle finger when scanning the fingerprint. The
authentication rate can be reduced if it is difficult to place another finger at the center of fingerprint sensor accurately.

Fingerprint enroll method

wice).
Cautions for enrolling a fingerprint
When a fingerprint is recognized, it is compared with the initially registered fingerprint, so the initial fingerprint enroll is the most important. Pay attention to the following matters when enrolling the fingerprint.
Place the finger deep enough to contact with the sensor completely.
Place the center of the fingerprint in the center of the sensor.
If a finger has a cut or the fingerprint is blurry, select another finger for the fingerprint.
Scan the fingerprint correctly without moving according to the instruction on the screen.
If you make the finger upright so that the contact area with the sensor has decreased or the angle of finger has warped, fingerprint authentication
may not be performed.
When the fingerprint recognition fails
BioEntry P2 can recognize a fingerprint regardless of a change of season or finger condition. However, the authentication rate may vary according to the external environment or fingerprint input method.
If the fingerprint authentication cannot be done smoothly, it is recommended to take the following measures.
If the finger is smeared with water or sweat, dry off the finger and then scan the finger.
If the finger is too dry, blow your breath on the fingertips and then scan the finger.
If the finger has a cut, register the fingerprint of another finger.
The initially registered fingerprint often may have not been scanned correctly, so register the fingerprint again according to ‘Cautions for enrolling
a fingerprint’.
9

Installation

100 mm
470 mm
120 mm
400 mm
150 mm
300 mm
Note
Installation

Fixing the bracket and the product

1 Determine the correct position to install the bracket using the provided drilling template. Fix the bracket firmly using fixing screws
through the bracket to the position where BioEntry P2 will be installed.
If installing BioEntry P2 on a concrete wall, drill holes, insert PVC anchors, and fix them with fixing screws.
To avoid RF interference, a minimum separation distance must be maintained.
Wall thickness
Distance
Wall thickness Distance
Wall
Wall
300 mm
10
Loading...