OPERATING INSTRUCTIONS
Functional check and leakage check
After the OXYFLEX®- MF1100 membrane plate diffuser has been installed, a functional and leakage check must
be performed. In order to do this, fill the tank up to a level of approx. 10 cm above the top edge of the diffuser with
clean water. It is recommended to operate with minimum air amount (see tables on page 8), before the water level
reached the aeration grid, in order to avoid water ingress by some bad sealing.
To check the function visually, the diffusers are loaded with the specified amount of air in accordance with the
diffuser version (see tables on page 8).
After ensuring that all diffusers are functional, the air quantity is reduced in accordance with the diffuser version
(see tables on page 8) in order to make it easier to perform the leakage check. Rising large bubbles indicate leaks
(e.g. due to gaskets that have been dislodged) those must be remedied.
The successfully performed functional and leakage check must be documented and the water level increased to at
least 100 cm above the top edge of the diffuser as quickly as possible.
Diffuser run-in
Different procedures are recommended depending on the membrane material and the diffuser version:
• EPDM membranes:
The compressed air must not be turned off between the function and leak-tightness check and the run-in of
the diffuser. OXYFLEX®- MF1100 membrane plate diffusers with EPDM membranes must be operated
continuously for at least 60 hours with the specified specific load (see run-in of diffusers in table 1 on page 8).
• TPU membranes:
OXYFLEX®- MF1100 membrane plate diffusers with TPU membranes do not have to be run in for normal
operation. However, a bubble pattern test or an oxygen transfer test can be carried out no sooner than 24
hours after start-up (for specific load see table 2 on page 8).
Deviating procedures are possible in consultation with Supratec.
Bubble pattern
The bubble pattern should be assessed no sooner than when the above-described run-in of the diffusers has been
completed. For this purpose the diffusers are operated from the maximum down to the minimum specific load.
The evenness of the aeration (bubble pattern test) should be checked when the tank is filled to a level of approx.
100 cm of water above the diffuser top edge.
Checking the evenness of the aeration is only possible at a water temperature of above 10°C.
Oxygen transfer test
Prior to carrying out an oxygen transfer test as proof of the efficiency of the OXYFLEX®- MF1100 membrane plate
diffuser, the above-mentioned steps must have been completed.
The oxygen transfer test can be carried out in accordance with the accepted regulations (e.g. DIN EN 12255-15
: 2003 or DWA-M 209) using the fresh water or waste water method. Specified warranty values must be rigorously
adhered to. A calibrated and exact measurement of the air volume is required.
Commissioning
If commissioning is delayed and/or system is decommissioned later on, it must be ensured that the diffusers are
sufficiently covered by water (at least 100 cm) so that the OXYFLEX®- MF1100 membrane plate diffuser is
protected against strong sun, frost and mechanical damage caused by falling objects, for example.
After successful commissioning, a reference pressure loss measurement enables the evaluation of actual state of
aeration system in operation.