SPECIFICATION
NAME OF APPLIANCE SUPERTRON COMMERCIAL DEEP FRYER
MOFRL NO. DF-400, DF-800, DF-1200
MANUFACTURED BY TU’S BROS PTY LTD
CERTIFICATE NO. 6139
Heavy Duty Commercial Deep Fat Fryer manufactured in stainless steel outer panels with stainless steel pan, in single,
double or triple units. Heating of the unit is by means of duck bill burners mounted on a cast ‘U’ shape manifold. The
burner is located beneath the fry pan. The fryer has a deep cool zone and comes equipped with complete flame failure
and over temperature cut out. The temperature of the oil is thermostatically controlled. The splashback incorporates the
flue system from the combustion chamber. The flue outlet at the top of splashback deflects the products of combustion
from the rear walls. The outer panels are attached to a square sub frame which is rust proofed.
Exterior Panels 304-N4x1.2mm stainless steel
Sub Frame 20x20x1.2 square tube
Fry Pan 2.0mm stainless steel
Rear Panel 1.2mm aluminised steel
Insulation Fibre Millboard incapsulated within a metal casing
Heating of Unit Is by means of individual duck bill burners. The burners are mounted
Number of Duck Bill Burners 16 x 1.05mm orifice N.G.
Primary Aeration Fixed Ø6mmx8mm up from should of thread.
Burner Supports Provided by 25mmx25mm angle iron welded to main frame.
Vessel Clearance Highest sloping point of pan from top of cast manifold 300mm
Fluing 2x70x70 holes from combustion chamber into a rectangular vertical
Overall Dimensions
Height over splashback 1130mm
Width 400mm (DF-400), 800mm (DF-800), 1200mm (DF-1200)
Depth (front to back) 790mm
Working Height 900mm
Leg Height 150mm
Gas Inlet A ¾" B.S.P connection is provided for each pan.
Gas Regulator Within Nova 820 M.V. Combination Control
Thermostat S.I.T. Nova 820 M.V. thermostatically operated combination control
Hi Limit Over Temperature Cut
Out
Oil Drain Valve 1" B.S.P (25mm)
77 MAIN ROAD, CLAYTON SOUTH
VIC 3169 AUSTRALIA
General Description
onto a cast ‘U’ form manifold 40mmx40mmx3mm Square section.
Overall length 405mmx160mm centres. Duck Bill 45mm centres.
16 x 0.65mm orifice LPG
rising flue 50mmx300mm
276mm above floor x 90mm from left hand side
Approval No. 4032. In circuit with Robert Shaw LCCM operation
switch. Thermostat E.G.O. Model 55/130/42 Range 230-205,
Approval No. 4270.
Robert Shaw Model LCCM 5525-028 Approval No.2263
Depth of Cool Well 270mm
Width of Cool Well 92mm
Operating Oil Level from Top of
Pan
Thermostat Capillary Location (Bulb) 210mm from top of pan ledge x 50mm centres
Hi Limit Capillary Location (Bulb) 210mm from top of pan ledge x 50mm centres
80mm