Supero X9DRG-HTF+ Plus, X9DRG-HF+ User Manual

Page 1
USER’S MANUAL
Revision 1.0a
X9DRG-HF+
X9DRG-HTF+
Page 2
Manual Revision 1.0a
Unless you request and receive written permission from Super Micro Computer, Inc., you may not copy any part of this document.
Information in this document is subject to change without notice. Other products and companies referred to herein are trademarks or registered trademarks of their respective companies or mark holders.
Copyright © 2013 by Super Micro Computer, Inc. All rights reserved.
Printed in the United States of America
The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccuracies that may be contained in this document, and makes no commitment to update or to keep current the information in this manual, or to notify any person or organization of the updates. Please Note: For the most up-to-date version of this
manual, please see our Website at www.supermicro.com.
Super Micro Computer, Inc. ("Supermicro") reserves the right to make changes to the product described in this manual at any time and without notice. This product, including software and docu­mentation, is the property of Supermicro and/or its licensors, and is supplied only under a license. Any use or reproduction of this product is not allowed, except as expressly permitted by the terms of said license.
IN NO EVENT WILL SUPER MICRO COMPUTER, INC. BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL, SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO USE THIS PRODUCT OR DOCUMENTATION, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. IN PARTICULAR, SUPER MICRO COMPUTER, INC. SHALL NOT HAVE LIABILITY FOR ANY HARDWARE, SOFTWARE, OR DATA STORED OR USED WITH THE PRODUCT, INCLUDING THE COSTS OF REPAIRING, REPLACING, INTEGRATING, INSTALLING OR RECOVERING SUCH HARDWARE, SOFTWARE, OR DATA.
Any disputes arising between the manufacturer and the customer shall be governed by the laws of Santa Clara County in the State of California, USA. The State of California, County of Santa Clara shall be the exclusive venue for the resolution of any such disputes. Supermicro's total liability for all claims will not exceed the price paid for the hardware product.
FCC Statement: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the manufacturer’s instruction manual, may cause harmful interference with radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case you will be required to correct the interference at your own expense.
California Best Management Practices Regulations for Perchlorate Materials: This Perchlorate warning applies only to products containing CR (Manganese Dioxide) Lithium coin cells. “Perchlorate Material-special handling may apply. See www.dtsc.ca.gov/hazardouswaste/perchlorate”.
WARNING: Handling of lead solder materials used in this product may expose you to lead, a chemical known to the State of California to cause birth defects and other reproductive harm.
Page 3
Preface
This manual is written for system integrators, PC technicians and
knowledgeable PC users. It provides information for the installation and use of the
X9DRG-HF+/X9DRG-HTF+ motherboard.
About This Motherboard
The Super X9DRG-HF+/X9DRG-HTF+ motherboard supports dual Intel E5-2600
Series Processors (Socket R) which offers QPI (Intel QuickPath Interface) Technol-
ogy (V.1.1) providing point-to-point connection with a transfer speed of up to 8.0
GT/s. With the PCH C602J chipset built in, the X9DRG-HF+/HTF+ motherboard
supports Intel® Intelligent Power Node Manager, Manageability Engine (ME), Rapid
Storage Technology, Digital Media Interface (DMI), PCI-E Gen. 3.0 and 1600 MHz
DDR3 memory. This motherboard is ideal for GPU (Graphics Processing Unit) server
platforms. Please refer to our Website (http://www.supermicro.com) for CPU and
memory support updates.
Manual Organization
Chapter 1 describes the features, specications and performance of the mother-
board, and provides detailed information about the Intel PCH chipset.
Chapter 2 provides hardware installation instructions. Read this chapter when in-
stalling the processor, memory modules and other hardware components into the
system. If you encounter any problems, see Chapter 3, which describes trouble-
shooting procedures for video, memory, and system setup stored in CMOS.
Chapter 4 includes an introduction to the BIOS, and provides detailed information
on running the CMOS Setup utility.
Appendix A provides BIOS Error Beep Codes.
Appendix B lists Software Installation Instructions.
Preface
iii
Page 4
iv
Conventions Used in the Manual
Pay special attention to the following symbols to ensure proper system installation
and to prevent damage to the system or injury to yourself:
Warning: Important information given to ensure proper system installation or to prevent
damage to the components
Note: Additional information given to differentiate between various models
or provides information for correct system setup.
X9DRG-HF+/X9DRG-HTF+ Motherboard User’s Manual
Page 5
Preface
v
Contacting Supermicro
Headquarters
Address: Super Micro Computer, Inc.
980 Rock Ave.
San Jose, CA 95131 U.S.A.
Tel: +1 (408) 503-8000
Fax: +1 (408) 503-8008
Email: [email protected] (General Information)
[email protected] (Technical Support)
Web Site: www.supermicro.com
Europe
Address: Super Micro Computer B.V.
Het Sterrenbeeld 28, 5215 ML
's-Hertogenbosch, The Netherlands
Tel: +31 (0) 73-6400390
Fax: +31 (0) 73-6416525
Email: [email protected] (General Information)
[email protected] (Technical Support)
[email protected] (Customer Support)
Asia-Pacic
Address: Super Micro Computer, Inc.
4F, No. 232-1, Liancheng Rd
Chung-Ho Dist., New Taipei City 235
Taiwan
Tel: +886-(2) 8226-3990
Fax: +886-(2) 8226-3991
Web Site: www.supermicro.com.tw
Technical Support:
Tel: +886-(2)-8226-3990
Page 6
vi
Table of Contents
Preface
Chapter 1 Overview
1-1 Overview ......................................................................................................... 1-1
1-2 Processor and Chipset Overview.................................................................. 1-10
1-3 Special Features ............................................................................................1-11
1-4 PC Health Monitoring .....................................................................................1-11
1-5 ACPI Features ............................................................................................... 1-12
1-6 Power Supply ................................................................................................ 1-12
1-7 Super I/O ....................................................................................................... 1-13
1-8 Advanced Power Management ..................................................................... 1-13
Intel® Intelligent Power Node Manager (NM) ................................................ 1-13
Management Engine (ME) ............................................................................ 1-13
1-9 Overview of the Nuvoton WPCM450 Controller ........................................... 1-13
Chapter 2 Installation
2-1 Standardized Warning Statements ................................................................. 2-1
2-2 Static-Sensitive Devices .................................................................................. 2-4
2-3 Processor and Heatsink Installation................................................................ 2-5
Installing the LGA2011 Processor ................................................................. 2-5
Installing a Passive CPU Heatsink ................................................................. 2-9
Removing the Heatsink ................................................................................. 2-10
2-4 Installing and Removing the Memory Modules ..............................................2-11
Installing & Removing DIMMs ........................................................................2-11
Removing Memory Modules ..........................................................................2-11
2-5 Motherboard Installation ................................................................................ 2-15
Tools Needed ................................................................................................ 2-15
Location of Mounting Holes .......................................................................... 2-15
Installing the Motherboard ............................................................................ 2-16
2-6 Control Panel Connectors and I/O Ports ...................................................... 2-17
Back Panel Connectors and I/O Ports .......................................................... 2-17
Back Panel I/O Port Locations and Denitions ........................................... 2-17
Universal Serial Bus (USB) ...................................................................... 2-18
Video Connection ..................................................................................... 2-18
Ethernet Ports .......................................................................................... 2-19
Unit Identier Switch ................................................................................ 2-20
Front Control Panel ....................................................................................... 2-21
Front Control Panel Pin Denitions............................................................... 2-22
NMI Button ............................................................................................... 2-22
X9DRG-HF+/X9DRG-HTF+ Motherboard User’s Manual
Page 7
vii
Table of Contents
Power LED .............................................................................................. 2-22
HDD LED/UID Switch ............................................................................... 2-23
NIC1/NIC2 LED Indicators ....................................................................... 2-23
Overheat (OH)/Fan Fail/PWR Fail/UID LED ............................................ 2-24
Power Fail LED ........................................................................................ 2-24
Reset Button ........................................................................................... 2-25
Power Button ........................................................................................... 2-25
2-7 Connecting Cables ........................................................................................ 2-26
Power Connectors ................................................................................... 2-26
Fan Headers ............................................................................................. 2-27
Chassis Intrusion ..................................................................................... 2-27
Serial Ports ............................................................................................... 2-28
TPM Header/Port 80 ................................................................................ 2-29
Overheat LED/Fan Fail ............................................................................ 2-29
T-SGPIO1/2/-S Headers ........................................................................... 2-30
SMBus Headers ....................................................................................... 2-30
Speaker Header ....................................................................................... 2-31
DOM Power Connector ............................................................................ 2-31
2-8 Jumper Settings ............................................................................................ 2-32
Explanation of Jumpers ................................................................................ 2-32
GLAN Enable/Disable .............................................................................. 2-32
CMOS Clear ............................................................................................. 2-33
Watch Dog Enable/Disable ...................................................................... 2-33
VGA Enable .............................................................................................. 2-34
BMC Enable ............................................................................................ 2-34
Management Engine (ME) Recovery ...................................................... 2-35
Manufacturer Mode Select ....................................................................... 2-35
2-9 Onboard LED Indicators ............................................................................... 2-36
LAN LEDs ................................................................................................. 2-36
IPMI Dedicated LAN LEDs ....................................................................... 2-36
Onboard Power LED ............................................................................... 2-37
BMC Heartbeat LED ................................................................................ 2-37
Rear UID LED ......................................................................................... 2-38
2-10 Serial ATA Connections ................................................................................. 2-39
Serial ATA Ports........................................................................................ 2-39
Page 8
viii
Chapter 3 Troubleshooting
3-1 Troubleshooting Procedures ........................................................................... 3-1
3-2 Technical Support Procedures ........................................................................ 3-5
3-3 Battery Removal and Installation .................................................................... 3-6
3-4 Frequently Asked Questions ........................................................................... 3-7
3-5 Returning Merchandise for Service................................................................. 3-8
Chapter 4 BIOS
4-1 Introduction ...................................................................................................... 4-1
4-2 Main Setup ...................................................................................................... 4-2
4-3 Advanced Setup Congurations...................................................................... 4-4
4-4 Event Logs .................................................................................................... 4-25
4-5 IPMI ............................................................................................................... 4-27
4-6 Boot ............................................................................................................... 4-29
4-7 Security ......................................................................................................... 4-30
4-8 Save & Exit ................................................................................................... 4-31
Appendix A BIOS Error Beep Codes
A-1 BIOS Error Beep Codes .................................................................................A-1
Appendix B Software Installation Instructions
B-1 Installing Software Programs ..........................................................................B-1
B-2 Conguring SuperDoctor® III ..........................................................................B-2
X9DRG-HF+/X9DRG-HTF+ Motherboard User’s Manual
Page 9
Chapter 1: Overview
1-1
Chapter 1
Overview
1-1 Overview
Checklist
Congratulations on purchasing your computer motherboard from an acknowledged
leader in the industry. Supermicro boards are designed with the utmost attention to
detail to provide you with the highest standards in quality and performance.
This motherboard was designed to be used in an SMC-proprietary server as a part
of an integrated system platform.
Note: For your system to work properly, please follow the links below to
download all necessary drivers/utilities and the user's manual for your
motherboard.
•SMCI product manuals: http://www.supermicro.com/support/manuals/
•Product Drivers and utilities: ftp://ftp.supermicro.com/
Warning: For safety considerations, please refer to the complete list of safety warn-
ings posted on the Supermicro website at http://www.supermicro.com/about/policies/
safety_information.cfm.
If you have any questions, please contact our support team at support@supermicro.
com.
Page 10
1-2
X9DRG-HF+/X9DRG-HTF+ Motherboard User’s Manual
Motherboard Image
Note: All graphics shown in this manual were based upon the latest PCB
Revision available at the time of publishing of the manual. The motherboard
you've received may or may not look exactly the same as the graphics
shown in this manual.
Page 11
Chapter 1: Overview
1-3
Motherboard Layout
Note: For the latest CPU/Memory updates, please refer to our Website at
http://www.supermicro.com/products/motherboard/ for details.
T-SGPIO1
T-SGPIO2
I-SATA0
COM1
JSD1
LE4
SW1
JPW10
LAN2
LAN1
JL1
JOH1
JSPK1
JPLD1
JI2C2
JI2C1
JPW7
JPW4
JPW3
JVGA1
JPW9
JPW1
Battery
LE1
DM1
JWD1
J30
JPB1
J29
JPL1
JPG1
FAND
FANC
FANB
FANA
FAN4
FAN3
FAN2
FAN1
FANH
FANG
FANF
FANE
JF1
JPW2
JTPM1
JITP0
SXB1B PCI-E 3.0 X16
SXB4 PCI-E 3.0 X16
CPU2
SXB3 PCI-E 3.0 X16
SXB2 PCI-E 3.0 X16
SXB1C
P1-DIMMA1
P1-DIMMA2
P1-DIMMB1
P1-DIMMB2
P2-DIMMG1
P2-DIMMG2
P2-DIMMH1
P2-DIMMH2
P1-DIMMD2
P1-DIMMD1
P1-DIMMC2
P1-DIMMC1
P2-DIMMF2
P2-DIMMF1
P2-DIMME2
P2-DIMME1
CPU1
IPMI LAN
SXB5 PCI-E 3.0 x8 in x16
SXB1A
JPW6 JPW5
I-SATA1
I-SATA2
I-SATA3
I-SATA4
I-SATA5
JBT1
BIOS
PCH
C602J
LAN CTRL
BMC
X9DRG-HF+ Rev. 1.01
CLOSE 1st
OPEN 1st
CLOSE 1st
OPEN 1st
USB0/1
JPME2
JPME1
Page 12
1-4
X9DRG-HF+/X9DRG-HTF+ Motherboard User’s Manual
Notes:
•See Chapter 2 for detailed information on jumpers, I/O ports and JF1 front
panel connections.
•" " indicates the location of "Pin 1".
•Jumpers/LED Indicators not indicated are for testing only.
•Use only the correct type of onboard CMOS battery as specied by the manufac-
turer. Do not install the onboard battery upside down to avoid possible explosion.
•The X9DRG-HTF+ supports two X540-based 10G LAN ports; the X9DRG-HF+
supports two I350-based 1G LAN ports.
X9DRG-HF+/X9DRG-HTF+ Quick Reference
T-SGPIO1
T-SGPIO2
I-SATA0
COM1
JSD1
LE4
SW1
JPW10
LAN2
LAN1
JL1
JOH1
JSPK1
JPLD1
JI2C2 JI2C1
JPW7
JPW4
JPW3
JVGA1
JPW9
JPW1
Battery
LE1
DM1
JWD1
J30
JPB1
J29
JPL1
JPG1
FAND
FANC
FANB
FANA
FAN4
FAN3
FAN2
FAN1
FANH
FANG
FANF
FANE
JF1
JPW2
JTPM1
JITP0
SXB1B PCI-E 3.0 X16
SXB4 PCI-E 3.0 X16
CPU2
SXB3 PCI-E 3.0 X16
SXB2 PCI-E 3.0 X16
SXB1C
P1-DIMMA1
P1-DIMMA2
P1-DIMMB1
P1-DIMMB2
P2-DIMMG1
P2-DIMMG2
P2-DIMMH1
P2-DIMMH2
P1-DIMMD2
P1-DIMMD1
P1-DIMMC2
P1-DIMMC1
P2-DIMMF2
P2-DIMMF1
P2-DIMME2
P2-DIMME1
CPU1
IPMI LAN
SXB5 PCI-E 3.0 x8 in x16
SXB1A
JPW6 JPW5
I-SATA1
I-SATA2
I-SATA3
I-SATA4
I-SATA5
JBT1
BIOS
PCH
C602J
LAN CTRL
BMC
X9DRG-HF+ Rev. 1.01
CLOSE 1st
OPEN 1st
CLOSE 1st
OPEN 1st
USB0/1
JPME2
JPME1
Page 13
Chapter 1: Overview
1-5
X9DRG-HF+/X9DRG-HTF+ Jumpers
Jumper
Description Default Setting
JBT1 Clear CMOS See Chapter 2
JPB1 BMC Enabled Pins 1-2 (Enabled)
JPG1 VGA Enabled Pins 1-2 (Enabled)
JPL1 GLAN1/GLAN2 Enable Pins 1-2 (Enabled)
JPME1 Management Engine (ME)
Recovery Mode
Pins 1-2 (Normal)
JPME2 Management Engine (ME)
Manufacture Mode
Pins 1-2 (Normal)
JWD1 Watch Dog Timer Enable Pins 1-2 (Reset)
X9DRG-HF+/X9DRG-HTF+ Connectors
Connectors Description
BT1 Onboard Battery (See Chpt. 3 for Used Battery Disposal)
COM1 Serial Port (COM1) Header
FAN1~4 CPU Fans
FANA~H GPU Fans
JF1 Front Panel Control Header
JL1 Chassis Intrusion
JOH1 Overheat LED Indicator
JI2C1/JI2C2 SMBbus I2C Headers (for SXB5 PCI-E Slot)
JPW1 SMC-Proprietary 62-pin PWR Connector (Warning-Next Page)
JPW2 SMC-Proprietary 20-pin PWR Connector (Warning-Next Page)
JPW3, JPW4, JPW5-7
12V 8-pin PWR Connectors (Warning-Next Page)
JPW9 SMC-Proprietary 38-pin PWR Connector (Warning-Next Page)
JPW10 12V/5V 4-pin HDD PWR Connectors (Warning-Next Page)
JSD1 SATA DOM (Devices on Module) Power Connector
JSPK1 Speaker Header (for an Onboard Buzzer)
JTPM1 TPM (Trusted Platform Module)/Port 80
JVGA1 Backpanel VGA Port
LAN1/LAN2 X540_based 10G Ethernet LAN Ports 1/2 (X9DRG-HTF+);
I350_based 1G LAN Ports 1/2 (X9DRG-HF+)
(IPMI) LAN IPMI_Dedicated LAN
(I-)SATA 0-5 SATA 3.0 Connectors (I-SATA 0/1), SATA 2.0 Connectors (I-
SATA 2-5)
SXB1A/1B/1C PCI-E 3.0x16 Slots
SXB2-4 PCI-E 3.0 x16 Slots
Page 14
1-6
X9DRG-HF+/X9DRG-HTF+ Motherboard User’s Manual
SXB5 PCI-E 3.0 x8 in x16 Slot
SW1 UID Switch
T-SGPIO1/2 Serial_Link General Purpose I/O Headers 0/1 for I-SATA Ports
0~5
USB 0/1 Back Panel USB 0/1
X9DRG-HF+/X9DRG-HTF+ LED Indicators
LED Description State Status
DM1 BMC Heartbeat LED Green BMC Normal
LE1 Standby PWR LED Green: On SB Power On
LE4 UID Switch LED
Warning: To provide adequate power supply to the system, be sure to connect all
onboard power connectors to the power supply.
Page 15
Chapter 1: Overview
1-7
Motherboard Features
CPU
• Dual Intel
®
E5-2600 Series Processors (Socket R-
LGA 2011); each processor supports four full-width
Intel QuickPath Interconnect (QPI) links (with support
of up to 25.6 GT/s per QPI link and with Data Trans-
fer Rate of up to 8.0 GT/s per direction)
Memory
• 240-pin Registered (RDIMM)/Load Reduced
(LRDIMM) ECC or Unbuffered (UDIMM) ECC/Non-
ECC DDR3 800/1066/1333/1600 MHz memory mod-
ules of up to 512 GB in 4-channel 16 DIMM modules
Note: For the latest CPU/memory updates,
please refer to our Website at http://www.su-
permicro.com/products/motherboard.
Chipset
• Intel
®
C602J PCH
Expansion
• Two (2) PCI-E 3.0 x16 slots for GPU use (SXB3,
SXB4),
• Two (2) PCI-E 3.0 x16 slots (SXB1A/1B/1C, SXB2),
• One (1) PCI-E 3.0 x8 in x16 slot (SXB5),
Slots
Graphics
• Nuvoton BMC Video Controller (Matrox G200)
Network
• One Intel I350 Gigabit (10/100/1000 Mb/s) Ethernet
Dual-Channel Controller for LAN 1/LAN 2 ports (for
X9DRG-HF+),
• One Intel X540 Dual-Channel Controller for 10G-
based-T LAN 1/LAN 2 ports (for X9DRG-HTF+)
I/O Devices
SATA Connections
• SATA Ports Two (2): SATA 3.0 Ports (I-
SATA0/1)
Four (4) SATA 2.0 Ports (I-
SATA2~5) (from AHCI)
• RAID RAID 0, 1, 5, 10
IPMI 2.0
• IPMI 2.0 supported by the Nuvoton WPCM450R
BMC
Serial (COM) Port
• One (1) Fast UART 16550 Connection: 9-pin RS-
232 Header
Peripheral Devices
USB Devices
• Two (2) USB ports on the rear I/O panel (USB 0/1),
Page 16
1-8
X9DRG-HF+/X9DRG-HTF+ Motherboard User’s Manual
BIOS
• 128 Mb SPI AMI BIOS
®
SM Flash BIOS
• APM 1.2, PCI 2.3, ACPI 1.0/2.0/3.0, USB Keyboard,
Plug & Play (PnP) and SMBIOS 2.5
Power
• ACPI/ACPM Power Management
Management
• Main switch override mechanism
• Keyboard Wake-up from Soft-Off
• Power-on mode for AC power recovery
• Intel
®
Intelligent Power Node Manager (Available
when the supporting rmware and the power supply
cable are installed on the motherboard.)
• Management Engine
PC Health
CPU Monitoring
Monitoring
• Onboard voltage monitors for CPU Core, Memory
Power, +3.3V, 3.3VSB, +5V, +5V Dual, +12V, HT,
Chipset, and Battery Voltages.
• CPU Thermal Design Power (TDP): support up to
135W (See Note 1 below.)
• CPU 5+1 -Phase switching voltage regulator
• CPU/System overheat LED and control
• CPU Thermal Trip support
• Thermal Monitor 2 (TM2) support
Fan Control
• Fan status monitoring with rmware thermal man-
agement via IPMI interface
• Low noise fan speed control
System Management
• PECI (Platform Environment Conguration Interface)
2.0 support
• System resource alert via SuperDoctor® III
• SuperoDoctor® III, Watch Dog, NMI
• Chassis Intrusion Header and Detection
Dimensions
• 19.80" (L) x 10.90" (W) (502.92 mm x 276.86 mm)
Note 1: CPU Maximum Thermal Design Power (TDP) is subject to chassis
and heatsink cooling restrictions. For proper thermal management, please
check the chassis and heatsink specications for proper CPU TDP sizing.
Note 2: For IPMI Conguration Instructions, please refer to the Embedded
IPMI Conguration User's Guide available @ http://www.supermicro.com/
support/manuals/.
Page 17
Chapter 1: Overview
1-9
System Block Diagram
Note: This is a general block diagram and may not exactly represent the
features on your motherboard. See the Motherboard Features pages for
the actual specications of each motherboard.
#H-2
#H-1
#G-2
#G-1
#F-2
#F-1
#E-2
I350/X540
LAN
PCI-E X8 in x16
I-SATA
USB 2.0
USB
2 Rear
3.0 Gb/S
6.0 Gb/S
I-SATA
PORTs#2~5
DDRIII
P1
P1
P0
P0
#E-1
#D-2
#D-1
#C-2
#C-1
#B-2
#B-1
#A-2
#A-1
QPI
8G
SXB 1
SXB 5
E5-2600 Series
CPU1 CPU2
PCH
C602
PCI-E X16 Gen3
DMI2
SPI
Dedicated LAN
VGA port
DMI2
BMC
WPCM450
PCI-E X16
PCI-E X16 Gen3
PCI
SATA2
SATA3
E5-2600 Series
DMI2
DMI2
#2 #3 #1 #1 #2 #3
QPI
8G
PCI-E X16
VGA
PCI-E X8 Gen3
PCI-E X16
PCI-E X16
SATA
PORTs#0~1
SATA
#2~#5
#0~#1
#0~#1
PCI-E X8 Gen3
PCI-E X16 Gen3
PCI-E X16 Gen3
COM Port
Internal
Header
PCI
SXB 3
SXB 2
SXB 4
DDRIII
Page 18
1-10
X9DRG-HF+/X9DRG-HTF+ Motherboard User’s Manual
1-2 Processor and Chipset Overview
Built upon the functionality and the capability of Intel E5-2600 Series Processors
(Socket R) and the C602J chipset, the X9DRG-HF+/X9DRG-HTF+ motherboard
provides the performance and feature sets required for dual_processor-based 1U
or 2U GPU server platforms.
With support of Intel QuickPath interconnect (QPI) Technology, the X9DRG-HF+/
X9DRG-HTF+ offers point-to-point serial interconnect interface with a transfer
speed of up to 8.0 GT/s, providing superb system performance.
The PCH chipset provides extensive IO support, including the following functions
and capabilities:
•PCI-Express Rev. 2.0 support
•ACPI Power Management Logic Support Rev. 3.0b or Rev. 4.0
•USB host interface backplane and front access support
•Intel Rapid Storage Technology supported
•Intel Virtualization Technology for Directed I/O (Intel VT-d) supported
•Intel Trusted Execution Technology supported
•Serial Peripheral Interface (SPI) Supported
•Digital Media Interface (DMI) supported
•Advanced Host Controller Interface (AHCI) supported
Page 19
Chapter 1: Overview
1-11
1-3 Special Features
Recovery from AC Power Loss
The Basic I/O System (BIOS) provides a setting that determines how the system will
respond when AC power is lost and then restored to the system. You can choose for
the system to remain powered off (in which case you must press the power switch
to turn it back on), or for it to automatically return to the power-on state. See the
Advanced BIOS Setup section for this setting. The default setting is Last State.
1-4 PC Health Monitoring
This section describes the features of PC health monitoring of the motherboard.
This motherboard has an onboard System_Hardware_Monitor chip that supports
PC health monitoring. An onboard voltage monitor will scan the following onboard
voltages continuously:Onboard voltage monitors for +3.3V, 3.3VSB, +5V, +5V Dual,
+12V, HT, CPU Core, Memory, and Battery Voltages. Once a voltage becomes
unstable, a warning is given, or an error message is sent to the screen. The user
can adjust the voltage thresholds to dene the sensitivity of the voltage monitor.
Fan Status Monitor with Firmware Control
The PC health monitoring chip can check the RPM status of a cooling fan. The
onboard CPU and chassis fans are controlled by rmware thermal management
via IPMI interface.
Environmental Temperature Control
A thermal control sensor monitors the CPU temperature in real time and will turn
on the thermal control fan whenever the CPU temperature exceeds a user-dened
threshold. The overheat circuitry runs independently from the CPU. Once it detects
that the CPU temperature is too high, it will automatically turn on the thermal fan
control to prevent the CPU from overheating. The onboard chassis thermal circuitry
can monitor the overall system temperature and alert the user when the chassis
temperature is too high.
Note: To avoid possible system overheating, please be sure to provide
adequate airow to your system.
Page 20
1-12
X9DRG-HF+/X9DRG-HTF+ Motherboard User’s Manual
System Resource Alert
This feature is available when used with SuperDoctor III in the Windows OS
environment or used with SuperDoctor II in Linux. SuperDoctor is used to notify
the user of certain system events. For example, you can congure SuperDoctor
to provide you with warnings when the system temperature, CPU temperatures,
voltages, and fan speeds go beyond a predened range.
1-5 ACPI Features
ACPI stands for Advanced Conguration and Power Interface. The ACPI specica-
tion denes a exible and abstract hardware interface that provides a standard
way to integrate power management features throughout a PC system, including
its hardware, operating system and application software. This enables the system
to automatically turn on and off peripherals such as CD-ROMs, network cards, hard
disk drives and printers.
In addition to operating_system-directed power management, ACPI also provides
a generic system event mechanism for Plug and Play, and an operating system-
independent interface for conguration control. ACPI leverages the Plug and Play
BIOS data structures, while providing a processor architecture-independent imple-
mentation that is compatible with Windows 7, Windows Vista and Windows 2008
Operating Systems.
Slow Blinking LED for Suspend-State Indicator
When the CPU goes into a suspend state, the chassis power LED will start blinking
to indicate that the CPU is in suspend mode. When the user presses any key, the
CPU will "wake up," and the LED will automatically stop blinking and remain on.
1-6 Power Supply
As with all computer products, a stable power source is necessary for proper and
reliable operation. It is even more important for processors that have high CPU
clock rates.
The X9DRG-HF+/X9DRG-HTF+ motherboard supports SMC-Proprietary 62-pin,
38-pin, 20-pin power connectors and 12V 8-pin/4-pin power connectors. In areas
where noisy power transmission is present, you may choose to install a line lter
to shield the computer from noise. It is recommended that you also install a power
surge protector to help avoid problems caused by power surges.
Note: Please use SMC-proprietary power supply as specied as above.
This motherboard does not support any power supply manufactured by
other manufacturer.
Page 21
Chapter 1: Overview
1-13
1-7 Super I/O
The Super I/O supports one high-speed, 16550 compatible serial communication
header (UART). The UART includes a 16-byte send/receive FIFO, a programmable
baud rate generator, complete modem control capability, and a processor interrupt
system. The UART provides legacy speed with baud rate of up to 115.2 Kbps.
The Super I/O provides functions that comply with ACPI (Advanced Conguration
and Power Interface), which includes support of legacy and ACPI power manage-
ment through an SMI or SCI function pin. It also features auto power management
to reduce power consumption.
1-8 Advanced Power Management
The new advanced power management features supported by this motherboard
include IPNM and ME. Please note that you will need to do following to use these
two new features:
•Use a power supply that supports PMBus 1.1 or 1.2,
•Install the NMView software in your system. NMView is optional and can be
purchased from Supermicro.
Intel® Intelligent Power Node Manager (NM)
The Intel® Intelligent Power Node Manager (IPNM) provides your system with
real-time thermal control and power management for maximum energy efciency.
Although IPNM is supported by the BMC (Baseboard Management Controller),
your system must also have IPNM-compatible Management Engine (ME) rmware
installed in your system for IPNM support.
Note: Support for IPNM Specication Version 1.5 or Vision 2.0 depends
on the power supply used in the system.
Management Engine (ME)
The Management Engine, which is an ARC controller embedded in the PCH, pro-
vides Server Platform Services (SPS) to your system. The services provided by
SPS are different from those provided by the ME on client platforms.
1-9 Overview of the Nuvoton WPCM450 Controller
The Nuvoton WPCM450R Controller, a Baseboard Management Controller (BMC),
supports 2D/VGA-compatible Graphic Cores with PCI interface, creating multi-media
Page 22
1-14
X9DRG-HF+/X9DRG-HTF+ Motherboard User’s Manual
virtualization via Keyboard/Video/Mouse Redirection (KVMR). The WPCM450R
Controller is ideal for remote system management.
The WPCM450R Controller interfaces with the host system via PCI connections
to communicate with the graphics cores. It supports USB 2.0 and 1.1 for remote
keyboard/mouse/virtual media emulation. It also provides LPC interface support to
control Super IO functions. The WPCM450R Controller is connected to the network
via an external Ethernet PHY module or shared NCSI connections.
The WPCM450R communicates with onboard components via six SMBus inter-
faces, PECI (Platform Environment Control Interface) buses, and General Purpose
I/O ports.
WPCM450R DDR2 Memory Interface
The WPCM450R supports a 16-bit DDR2 memory module with a speed of up to 220
MHz. For best signal integrity, the WPCM450R provides point-to-point connection.
WPCM450R PCI System Interface
The WPCM450R provides 32-bit, 33 MHz 3.3V PCI interface, which is compliant
with the PCI Local Bus Specication Rev. 2.3. The PCI system interface connects
to the onboard PCI Bridge used by the graphics controller.
Other Features Supported by the WPCM BMC Controller
The WPCM450R supports the following features:
•IPMI 2.0
•Serial over LAN
•KVM over LAN
•LAN Alerting-SNMP Trap
•Event Log
•X-Bus parallel interface for I/O expansion
•Multiple ADC inputs, Analog and Digital Video outputs
•SPI Flash Host BIOS and rmware bootstrap program supported
•Reduced Media Independent Interface (RMII)
Page 23
Chapter 1: Overview
1-15
•OS (Operating System) Independency
•Provides remote Hardware Health Monitoring via IPMI. Key features
•Provides Network Management Security via remote access/console redirection.
•Supports the following Management tools: IPMIView, CLI (Command Line
Interface)
•RMCP+ protocol supported
Note 1: For more information on IPMI conguration, please refer to the
IPMI User's Guide posted on our website at http://www.supermicro.com/
support/manuals/.
Note 2: The term "IPMI controller" and the term "BMC controller" can be
used interchangeably in this section.
Page 24
1-16
X9DRG-HF+/X9DRG-HTF+ Motherboard User’s Manual
Notes
Page 25
Chapter 2: Installation
2-1
Chapter 2
Installation
2-1 Standardized Warning Statements
The following statements are industry-standard warnings provided to warn the user
of situations when potential bodily injury may occur. Should you have questions or
experience difculty, contact Supermicro's Technical Support department for assis-
tance. Only certied technicians should attempt to install or congure components.
Read this section in its entirety before installing or conguring components in the
system.
Battery Handling
Warning! There is a danger of explosion if the battery is replaced incor-
rectly. Replace the battery only with the same or equivalent type recom-
mended by the manufacturer. Dispose of used batteries according to the
manufacturer's instructions. (Refer to Chapter 3 for more information on
used battery disposal.
Warnung
Bei Einsetzen einer falschen Batterie besteht Explosionsgefahr. Ersetzen Sie die Bat-
terie nur durch den gleichen oder vom Hersteller empfohlenen Batterietyp. Entsorgen
Sie die benutzten Batterien nach den Anweisungen des Herstellers.
¡Advertencia!
Existe peligro de explosión si la batería se reemplaza de manera incorrecta. Reem-
plazar la batería exclusivamente con el mismo tipo o el equivalente recomendado por
el fabricante. Desechar las baterías gastadas según las instrucciones del fabricante.
Page 26
2-2
X9DRG-HF+/X9DRG-HTF+ Motherboard User’s Manual
Attention
Danger d'explosion si la pile n'est pas remplacée correctement. Ne la remplacer que
par une pile de type semblable ou équivalent, recommandée par le fabricant. Jeter les
piles usagées conformément aux instructions du fabricant.
Waarschuwing
Er is ontplofngsgevaar indien de batterij verkeerd vervangen wordt. Vervang de batterij
slechts met hetzelfde of een equivalent type die door de fabrikant aanbevolen wordt.
Gebruikte batterijen dienen overeenkomstig fabrieksvoorschriften afgevoerd te worden.
هناكخطرمنانفجارفيحالةاستبدالالبطاريةبطريقةغيرصحيحةفعليك
استبدالالبطارية
فقطبنفسالنوعأومايعادلهاكماأوصتبهالشركةالمصنعة
تخلصمنالبطارياتالمستعملةوفقالتعليماتالشركةالصانعة
Page 27
Chapter 2: Installation
2-3
Product Disposal
Warning! Ultimate disposal of this product should be handled according
to all national laws and regulations.
Waarschuwing
De uiteindelijke verwijdering van dit product dient te geschieden in overeenstemming
met alle nationale wetten en reglementen.
Attention
La mise au rebut ou le recyclage de ce produit sont généralement soumis à des lois
et/ou directives de respect de l'environnement. Renseignez-vous auprès de l'organisme
compétent.
¡Advertencia!
Al deshacerse por completo de este producto debe seguir todas las leyes y regla-
mentos nacionales.
Warnung
Die Entsorgung dieses Produkts sollte gemäß allen Bestimmungen und Gesetzen des
Landes erfolgen.
التخلصالنهائيمنهذاالمنتجينبغيالتعاملمعهوفقالجميعالقوانين
واللوائحالوطنيةعند
Page 28
2-4
X9DRG-HF+/X9DRG-HTF+ Motherboard User’s Manual
2-2 Static-Sensitive Devices
Electrostatic Discharge (ESD) can damage electronic com ponents. To avoid dam-
aging your system board, it is important to handle it very carefully. The following
measures are generally sufcient to protect your equipment from ESD.
Precautions
•Use a grounded wrist strap designed to prevent static discharge.
•Touch a grounded metal object before removing the board from the antistatic
bag.
•Handle the board by its edges only; do not touch its components, peripheral
chips, memory modules or gold contacts.
•When handling chips or modules, avoid touching their pins.
•Put the motherboard and peripherals back into their antistatic bags when not
in use.
•For grounding purposes, make sure that your system chassis provides excellent
conductivity between the power supply, the case, the mounting fasteners and
the motherboard.
Unpacking
The motherboard is shipped in antistatic packaging to avoid static damage. When
unpacking the board, make sure that the person handling it is protected against
static.
Page 29
Chapter 2: Installation
2-5
OPEN 1st
WARNING!
2-3 Processor and Heatsink Installation
Warning: When handling the processor package, avoid placing direct pressure on
the label area.
Notes:
•Always connect the power cord last, and always remove it before adding,
removing or changing any hardware components. Make sure that you install
the processor into the CPU socket before you install the CPU heatsink.
•If you buy a CPU separately, make sure that you use an Intel-certied multi-
directional heatsink only.
•Make sure to install the system board into the chassis before you install
the CPU heatsink.
•When receiving a server board without a processor pre-installed, make sure
that the plastic CPU socket cap is in place and none of the socket pins are
bent; otherwise, contact your retailer immediately.
•Refer to the Supermicro website for updates on CPU support.
Press down
on
Load Lever
labeled 'Open 1st'.
Installing the LGA2011 Processor
1. There are two load levers on the LGA2011 socket. To open the socket cover,
rst press and release the load lever labeled 'Open 1st'.
OPEN 1st
WARNING!
1
2
Page 30
2-6
X9DRG-HF+/X9DRG-HTF+ Motherboard User’s Manual
Gently push down to pop the load plate open.
2. Press the second load lever labeled 'Close 1st' to release the load plate that
covers the CPU socket from its locking position.
3. With the lever labeled 'Close 1st' l fully retracted, gently push down on the
lever labeled 'Open 1st' to open the load plate. Lift the load plate to open it
completely.
OPEN 1st
WARNING!
OPEN 1st
WARNING!
1
2
Press down on
Load
Lever labeled 'Close 1st'
WARNING!
OPEN 1st
WARNING!
1
Pull lever away from the socket
2
Page 31
Chapter 2: Installation
2-7
1. Use your index nger and your thumb to loosen the lever and open the load
plate.
Socket Keys
CPU Keys
Warning: You can only install the CPU
inside the socket in one direction.
Make sure that it is properly inserted
into the CPU socket before closing the
load plate. If it doesn't close properly,
do not force it as it may damage your
CPU. Instead, open the load plate
again and double-check that the CPU
is aligned properly.
WARNING!
2. Use your thumb and index nger to hold the CPU on its edges. Align the CPU
keys, which are semi-circle cutouts, against the socket keys.
3. Once they are aligned, carefully lower the CPU straight down into the socket.
(Do not drop the CPU on the socket. Do not move the CPU horizontally or
vertically. Do not rub the CPU against the surface or against any pins of the
socket to avoid damaging the CPU or the socket.)
Page 32
2-8
X9DRG-HF+/X9DRG-HTF+ Motherboard User’s Manual
4. With the CPU inside the socket, inspect the four corners of the CPU to make
sure that the CPU is properly installed.
OPEN 1st
OPEN 1st
OPEN 1st
Lever Lock
Lever Lock
Push down and lock the
lever labeled 'Open 1st'
Push down and lock the lever
labeled 'Close 1st'.
Gently close the load plate.
1 2
3
4
5. Close the load plate with the CPU inside the socket. Lock the lever labeled
'Close 1st' rst, then lock the lever labeled 'Open 1st' second. Use your
thumb to gently push the load levers down to the lever locks.
Page 33
Chapter 2: Installation
2-9
Installing a Passive CPU Heatsink
1. Apply the proper amount of thermal grease to the heatsink.
2. Place the heatsink on top of the CPU so that the two mounting holes on the
heatsink are aligned with those on the retention mechanism.
3. Insert two push-pins on the sides of the heatsink through the mounting holes
on the motherboard, and turn the push-pins clockwise to lock them.
OPEN 1st
Motherboard
Screw#1
Screw#2
Mounting Holes
Page 34
2-10
X9DRG-HF+/X9DRG-HTF+ Motherboard User’s Manual
Removing the Heatsink
Warning: We do not recommend that the CPU or the heatsink be removed. However,
if you do need to uninstall the heatsink, please follow the instructions below to uninstall
the heatsink to prevent damage done to the CPU or the CPU socket.
1. Unscrew the heatsink screws from the motherboard in the sequence as
shown in the illustration below.
2. Gently wriggle the heatsink to loosen it from the CPU. (Do not use excessive
force when wriggling the heatsink!)
3. Once the CPU is loosened, remove the CPU from the CPU socket.
4. Remove the used thermal grease and clean the surface of the CPU and the
heatsink, Reapply the proper amount of thermal grease on the surface before
reinstalling the CPU and the heatsink. (D0 not reuse old thermal grease.)
Loosen screws in sequence as shown.
Screw#2
Motherboard
Screw#1
Screw#3
Screw#4
Page 35
Chapter 2: Installation
2-11
T-SGPIO1
T-SGPIO2
I-SATA0
COM1
JSD1
LE4
SW1
JPW10
LAN2
LAN1
JL1
JOH1
JSPK1
JPLD1
JI2C2 JI2C1
JPW7
JPW4
JPW3
JVGA1
JPW9
JPW1
Battery
LE1
DM1
JWD1
J30
JPB1
J29
JPL1
JPG1
FAND
FANC
FANB
FANA
FAN4
FAN3
FAN2
FAN1
FANH
FANG
FANF
FANE
JF1
JPW2
JTPM1
JITP0
SXB1B PCI-E 3.0 X16
SXB4 PCI-E 3.0 X16
CPU2
SXB3 PCI-E 3.0 X16
SXB2 PCI-E 3.0 X16
SXB1C
P1-DIMMA1
P1-DIMMA2
P1-DIMMB1
P1-DIMMB2
P2-DIMMG1
P2-DIMMG2
P2-DIMMH1
P2-DIMMH2
P1-DIMMD2
P1-DIMMD1
P1-DIMMC2
P1-DIMMC1
P2-DIMMF2
P2-DIMMF1
P2-DIMME2
P2-DIMME1
CPU1
IPMI LAN
SXB5 PCI-E 3.0 x8 in x16
SXB1A
JPW6 JPW5
I-SATA1
I-SATA2
I-SATA3
I-SATA4
I-SATA5
JBT1
BIOS
PCH C602J
LAN CTRL
BMC
X9DRG-HF+ Rev. 1.01
CLOSE 1st
OPEN 1st
CLOSE 1st
OPEN 1st
USB0/1
JPME2
JPME1
Release Tabs
Notches
2-4 Installing and Removing the Memory Modules
Note: Check Supermicro's Website for recommended memory modules.
CAUTION
Exercise extreme care when installing or removing DIMM
modules to prevent any possible damage.
Installing & Removing DIMMs
1. Insert the desired number of DIMMs into the memory slots, starting with P1-
DIMMA1. (For best performance, please use the memory modules of the
same type and speed in the same bank?)
2. Push the release tabs outwards on both ends of the DIMM slot to unlock it.
Removing Memory Modules
3. Align the key of the DIMM module with the receptive point on the memory
slot.
4. Align the notches on both ends of the module against the receptive points on
the ends of the slot.
5. Use two thumbs together to press the notches on both ends of the module
straight down into the slot until the module snaps into place.
6. Press the release tabs to the locking positions to secure the DIMM module
into the slot.
Press both notches straight
down into the memory slot at
the same time.
Press both notches on the ends of the DIMM module to unlock it. Once the DIMM
module is loosened, remove it from the memory slot.
Page 36
2-12
X9DRG-HF+/X9DRG-HTF+ Motherboard User’s Manual
Memory Support for the X9DRG-HF+/X9DRG-HTF+ Motherboard
The X9DRG-HF+/X9DRG-HTF+ Motherboard supports 240-pin Registered
(RDIMM)/Load Reduced (LRDIMM) ECC or Unbuffered (UDIMM) ECC/Non-ECC
DDR3 800/1066/1333/1600 MHz memory modules of up to 512 GB in 4-channel
16 DIMM modules. For the latest memory updates, please refer to our Website a
at http://www.supermicro.com/products/motherboard.
Processor & Memory Module Population Conguration
For memory to work properly, follow the tables below for memory installation.
Processors and their Corresponding Memory
Modules
CPU# Corresponding DIMM Modules
CPU 1
P1-DIMM
A1 A2 B1 B2 C1 C2 D1 D2
CPU2
P2-DIMM
E1 E2 F1 F2 G1 G2 H1 H2
Processor and Memory Module Population for Optimal Performance
Number of
CPUs+DIMMs
CPUandMemoryPopulationCongurationTable
(For memory to work properly, please follow the instructions below.)
1 CPU & 2 DIMMs
CPU1 P1-DIMMA1/P1-DIMMB1
1 CPU & 4 DIMMs
CPU1 P1-DIMMA1/P1-DIMMB1, P1-DIMMC1/P1-DIMMD1
1 CPU &
5~8 DIMMs
CPU1 P1-DIMMA1/P1-DIMMB1, P1-DIMMC1/P1-DIMMD1 + Any memory pairs in P1­DIMMA2/P1-DIMMB2/P1-DIMMC2/P1-DIMMD2 slots
2 CPUs &
4 DIMMs
CPU1 + CPU2 P1-DIMMA1/P1-DIMMB1, P2-DIMME1/P2-DIMMF1
2 CPUs &
6 DIMMs
CPU1 + CPU2 P1-DIMMA1/P1-DIMMB1/P1-DIMMC1/P1-DIMMD1, P2-DIMME1/P2-DIMMF1
2 CPUs &
8 DIMMs
CPU1 + CPU2 P1-DIMMA1/P1-DIMMB1/P1-DIMMC1/P1-DIMMD1, P2-DIMME1/P2-DIMMF1/P2­DIMMG1/P2-DIMMH1
2 CPUs &
10~16 DIMMs
CPU1/CPU2 P1-DIMMA1/P1-DIMMB1/P1-DIMMC1/P1-DIMMD1, P2-DIMME1/P2-DIMMF1/P2­DIMMG1/P2-DIMMH1 + Any memory pairs in P1, P2 DIMM slots
2 CPUs &
16 DIMMs
CPU1/CPU2 P1-DIMMA1/P1-DIMMB1/P1-DIMMC1/P1-DIMMD1, P2-DIMME1/P2-DIMMF1/P2-DIM­MG1/P2-DIMMH1,P1-DIMMA2/P1-DIMMB2/P1-DIMMC2/P1-DIMMD2, P2-DIMME2/ P2-DIMMF2/P2-DIMMG2/P2-DIMMH2
Page 37
Chapter 2: Installation
2-13
Populating UDIMM (ECC/Non-ECC) Memory Modules
Intel E5-2600 Series Processor UDIMM Memory Support
Ranks Per
DIMM &
Data Width
Memory Capacity
Per DIMM
(See the Note below)
Speed (MT/s) and Voltage Validated by Slot per Channel
(SPC) and DIMM Per Channel (DPC)
1 Slot Per Channel 2 Slots Per Channel
1DPC 1DPC 2DPC
1.35V 1.5V 1.35V 1.5V 1.35V 1.5V
SRx8
Non-ECC
1GB 2GB 4GB NA 1066, 1333,
1600
NA 1066,
1333
NA 1066,
1333
DRx8
Non-ECC
2GB 4GB 8GB NA 1066, 1333,
1600
NA 1066,
1333
NA 1066,
1333
SRx16
Non-ECC
512MB 1GB 2GB NA 1066, 1333,
1600
NA 1066,
1333
NA 1066,
1333
SRx8 ECC 1GB 2GB 4GB 1066,
1333
1066, 1333,
1600
1066,
1333
1066,
1333
1066 1066,
1333
DRx8 ECC 2GB 4GB 8GB 1066,
1333
1066, 1333,
1600
1066,
1333
1066,
1333
1066 1066,
1333
Note: For detailed information on memory support and updates, please refer to the SMC Recommended Memory List posted on our website at http://www.supermicro.com/support/resources/mem.cfm.
Populating RDIMM (ECC) Memory Modules
Intel E5-2600 Series Processor RDIMM Memory Support
Ranks
Per
DIMM
& Data
Width
Memory Capacity
Per DIMM
(See the Note Below)
Speed (MT/s) and Voltage Validated by Slot per Channel (SPC) and
DIMM Per Channel (DPC)
1 Slot Per Channel 2 Slots Per Channel
1DPC 1DPC 2DPC
1.35V 1.5V 1.35V 1.5V 1.35V 1.5V
SRx8 1GB 2GB 4GB 1066,
1333
1066, 1333,
1600
1066,
1333
1066, 1333,
1600
1066,
1333
1066, 1333,
1600
DRx8 2GB 4GB 8GB 1066,
1333
1066, 1333,
1600
1066,
1333
1066, 1333,
1600
1066,
1333
1066, 1333,
1600
SRx4 2GB 4GB 8GB 1066,
1333
1066, 1333,
1600
1066,
1333
1066, 1333,
1600
1066,
1333
1066, 1333,
1600
DRx4 4GB 8GB 16GB 1066,
1333
1066, 1333,
1600
1066,
1333
1066, 1333,
1600
1066,
1333
1066, 1333,
1600
QRx4 8GB 16GB 32GB 800 1066 800 1066 800 800
QRx8 4GB 8GB 16GB 800 1066 800 1066 800 800
Note: For detailed information on memory support and updates, please refer to the SMC Recommended
Memory List posted on our website at http://www.supermicro.com/support/resources/mem.cfm.
Page 38
2-14
X9DRG-HF+/X9DRG-HTF+ Motherboard User’s Manual
Populating LRDIMM (ECC) Memory Modules
Intel E5-2600 Series Processor LRDIMM Memory Support
Ranks Per
DIMM & Data
Width
(See the Note
Below)
Memory Capacity
Per DIMM
Speed (MT/s) and Voltage Validated
by Slot per Channel (SPC) and
DIMM Per Channel (DPC)
1 Slot Per
Channel
2 Slots Per
Channel
1DPC 1DPC and 2DPC
1.35V 1.5V 1.35V 1.5V
QRx4 (DDP) 16GB 32GB 1066,
1333
1066,
1333
1066 1066,
1333
QRx8 (P) 8GB 16GB 1066,
1333
1066,
1333
1066 1066,
1333
Note: For detailed information on memory support and updates, please refer to the SMC Recommended Memory List posted on our website at http://www.supermicro. com/support/resources/mem.cfm.
Other Important Notes and Restrictions
•For the memory modules to work properly, please install DIMM modules of the
same type, same speed and same operating frequency on the motherboard.
Mixing of RDIMMs, UDIMMs or LRDIMMs is not allowed. Do not install both
ECC and Non-ECC memory modules on the same motherboard.
•Using DDR3 DIMMs with different operating frequencies is not allowed. All chan-
nels in a system will run at the lowest common frequency.
Page 39
Chapter 2: Installation
2-15
T-SGPIO1
T-SGPIO2
I-SATA0
COM1
JSD1
LE4
SW1
JPW10
LAN2
LAN1
JL1
JOH1
JSPK1
JPLD1
JI2C2 JI2C1
JPW7
JPW4
JPW3
JVGA1
JPW9
JPW1
Battery
LE1
DM1
JWD1
J30
JPB1
J29
JPL1
JPG1
FAND
FANC
FANB
FANA
FAN4
FAN3
FAN2
FAN1
FANH
FANG
FANF
FANE
JF1
JPW2
JTPM1
JITP0
SXB1B PCI-E 3.0 X16
SXB4 PCI-E 3.0 X16
CPU2
SXB3 PCI-E 3.0 X16
SXB2 PCI-E 3.0 X16
SXB1C
P1-DIMMA1
P1-DIMMA2
P1-DIMMB1
P1-DIMMB2
P2-DIMMG1
P2-DIMMG2
P2-DIMMH1
P2-DIMMH2
P1-DIMMD2
P1-DIMMD1
P1-DIMMC2
P1-DIMMC1
P2-DIMMF2
P2-DIMMF1
P2-DIMME2
P2-DIMME1
CPU1
IPMI LAN
SXB5 PCI-E 3.0 x8 in x16
SXB1A
JPW6 JPW5
I-SATA1
I-SATA2
I-SATA3
I-SATA4
I-SATA5
JBT1
BIOS
PCH C602J
LAN CTRL
BMC
X9DRG-HF+ Rev. 1.01
CLOSE 1st
OPEN 1st
CLOSE 1st
OPEN 1st
USB0/1
JPME2
JPME1
2-5 Motherboard Installation
All motherboards have standard mounting holes to t different types of chassis.
Make sure that the locations of all the mounting holes for both motherboard and
chassis match. Although a chassis may have both plastic and metal mounting fas-
teners, metal ones are highly recommended because they ground the motherboard
to the chassis. Make sure that the metal standoffs click in or are screwed in tightly.
Then use a screwdriver to secure the motherboard onto the motherboard tray.
Tools Needed
•Phillips Screwdriver
•Pan head screws (8 pieces)
•Standoffs (9 pieces, if needed)
Location of Mounting Holes
There are nine (9) mounting holes on this motherboard indicated by the arrows.
Warning: 1) To avoid damaging the motherboard and its components, please do
not use a force greater than 8 lb/inch on each mounting screw during motherboard
installation. 2) Some components are very close to the mounting holes. Please take
precautionary measures to prevent damage to these components when installing the
motherboard to the chassis.
Page 40
2-16
X9DRG-HF+/X9DRG-HTF+ Motherboard User’s Manual
Installing the Motherboard
1. Install the I/O shield into the chassis.
2. Locate the mounting holes on the motherboard.
3. Locate the matching mounting holes on the chassis. Align the mounting holes
on the motherboard against the mounting holes on the chassis.
4. Install standoffs in the chassis as needed.
5. Install the motherboard into the chassis carefully to avoid damaging mother-
board components.
6. Using the Phillips screwdriver, insert a Pan head #6 screw into a mounting
hole on the motherboard and its matching mounting hole on the chassis.
7. Repeat Step 5 to insert #6 screws into all mounting holes.
8. Make sure that the motherboard is securely placed in the chassis.
Note: Images displayed are is for illustration only. Your chassis or compo-
nents might look different from those shown in this manual.
Page 41
Chapter 2: Installation
2-17
T-SGPIO1
T-SGPIO2
I-SATA0
COM1
JSD1
LE4
SW1
JPW10
LAN2
LAN1
JL1
JOH1
JSPK1
JPLD1
JI2C2 JI2C1
JPW7
JPW4
JPW3
JVGA1
JPW9
JPW1
Battery
LE1
DM1
JWD1
J30
JPB1
J29
JPL1
JPG1
FAND
FANC
FANB
FANA
FAN4
FAN3
FAN2
FAN1
FANH
FANG
FANF
FANE
JF1
JPW2
JTPM1
JITP0
SXB1B PCI-E 3.0 X16
SXB4 PCI-E 3.0 X16
CPU2
SXB3 PCI-E 3.0 X16
SXB2 PCI-E 3.0 X16
SXB1C
P1-DIMMA1
P1-DIMMA2
P1-DIMMB1
P1-DIMMB2
P2-DIMMG1
P2-DIMMG2
P2-DIMMH1
P2-DIMMH2
P1-DIMMD2
P1-DIMMD1
P1-DIMMC2
P1-DIMMC1
P2-DIMMF2
P2-DIMMF1
P2-DIMME2
P2-DIMME1
CPU1
IPMI LAN
SXB5 PCI-E 3.0 x8 in x16
SXB1A
JPW6 JPW5
I-SATA1
I-SATA2
I-SATA3
I-SATA4
I-SATA5
JBT1
BIOS
PCH
C602J
LAN CTRL
BMC
X9DRG-HF+ Rev. 1.01
CLOSE 1st
OPEN 1st
CLOSE 1st
OPEN 1st
USB0/1
JPME2
JPME1
2-6 Control Panel Connectors and I/O Ports
The I/O ports are color coded in conformance with the PC 99 specication. See
the picture below for the colors and locations of the various I/O ports.
Back Panel Connectors and I/O Ports
BackPanelI/OPortLocationsandDenitions
1. Back Panel USB Port 0
2. Back Panel USB Port 1
3. IPMI_Dedicated LAN
4. GLAN1 (X9DRG-HF+); TLAN1 (X9DRG-HTF+)
5. GLAN2 (X9DRG-HF+); TLAN2 (X9DRG-HTF+)
6. Back Panel VGA (Blue)
7. UID Switch
123
4
5
6
7
Page 42
2-18
X9DRG-HF+/X9DRG-HTF+ Motherboard User’s Manual
Video Connection
A Video (JVGA1) port is located next
to JLAN2 on the I/O backplane. Refer
to the board layout below for the
location.
1. BP USB0
2. BP USB1
3. VGA
Universal Serial Bus (USB)
Two Universal Serial Bus ports (USB
0/1) are located on the I/O back panel
to provide USB connections. (Cables
are not included). See the tables on
the right for pin denitions.
Backplane
USB
PinDenitions
Pin# Denition
1 +5V
2 PO-
3 PO+
4 Ground
5 NA
1
2
3
T-SGPIO1
T-SGPIO2
I-SATA0
COM1
JSD1
LE4
SW1
JPW10
LAN2
LAN1
JL1
JOH1
JSPK1
JPLD1
JI2C2 JI2C1
JPW7
JPW4
JPW3
JVGA1
JPW9
JPW1
Battery
LE1
DM1
JWD1
J30
JPB1
J29
JPL1
JPG1
FAND
FANC
FANB
FANA
FAN4
FAN3
FAN2
FAN1
FANH
FANG
FANF
FANE
JF1
JPW2
JTPM1
JITP0
SXB1B PCI-E 3.0 X16
SXB4 PCI-E 3.0 X16
CPU2
SXB3 PCI-E 3.0 X16
SXB2 PCI-E 3.0 X16
SXB1C
P1-DIMMA1
P1-DIMMA2
P1-DIMMB1
P1-DIMMB2
P2-DIMMG1
P2-DIMMG2
P2-DIMMH1
P2-DIMMH2
P1-DIMMD2
P1-DIMMD1
P1-DIMMC2
P1-DIMMC1
P2-DIMMF2
P2-DIMMF1
P2-DIMME2
P2-DIMME1
CPU1
IPMI LAN
SXB5 PCI-E 3.0 x8 in x16
SXB1A
JPW6 JPW5
I-SATA1
I-SATA2
I-SATA3
I-SATA4
I-SATA5
JBT1
BIOS
PCH
C602J
LAN CTRL
BMC
X9DRG-HF+ Rev. 1.01
CLOSE 1st
OPEN 1st
CLOSE 1st
OPEN 1st
USB0/1
JPME2
JPME1
Page 43
Chapter 2: Installation
2-19
1. GLAN1 (X9DRG-HF+), TLAN1 (X9DRG-HTF+)
2. GLAN2 (X9DRG-HF+), TLAN2 (X9DRG-HTF+)
3. IPMI_LAN
Ethernet Ports
Two Ethernet ports (LAN1, LAN2) are located on the I/O backplane on the moth-
erboard. These LAN ports support 1G LAN on the X9DRG-HF+, and support 10G
LAN on the X9DRG-HTF+. In addition, an IPMI_Dedicated LAN is located above
USB 0/1 ports on the backplane to provide KVM support for IPMI. All these ports
accept RJ45 type cables. Please refer to the LED Indicator Section for LAN LED
information.
1
2
3
T-SGPIO1
T-SGPIO2
I-SATA0
COM1
JSD1
LE4
SW1
JPW10
LAN2
LAN1
JL1
JOH1
JSPK1
JPLD1
JI2C2 JI2C1
JPW7
JPW4
JPW3
JVGA1
JPW9
JPW1
Battery
LE1
DM1
JWD1
J30
JPB1
J29
JPL1
JPG1
FAND
FANC
FANB
FANA
FAN4
FAN3
FAN2
FAN1
FANH
FANG
FANF
FANE
JF1
JPW2
JTPM1
JITP0
SXB1B PCI-E 3.0 X16
SXB4 PCI-E 3.0 X16
CPU2
SXB3 PCI-E 3.0 X16
SXB2 PCI-E 3.0 X16
SXB1C
P1-DIMMA1
P1-DIMMA2
P1-DIMMB1
P1-DIMMB2
P2-DIMMG1
P2-DIMMG2
P2-DIMMH1
P2-DIMMH2
P1-DIMMD2
P1-DIMMD1
P1-DIMMC2
P1-DIMMC1
P2-DIMMF2
P2-DIMMF1
P2-DIMME2
P2-DIMME1
CPU1
IPMI LAN
SXB5 PCI-E 3.0 x8 in x16
SXB1A
JPW6 JPW5
I-SATA1
I-SATA2
I-SATA3
I-SATA4
I-SATA5
JBT1
BIOS
PCH
C602J
LAN CTRL
BMC
X9DRG-HF+ Rev. 1.01
CLOSE 1st
OPEN 1st
CLOSE 1st
OPEN 1st
USB0/1
JPME2
JPME1
Page 44
2-20
X9DRG-HF+/X9DRG-HTF+ Motherboard User’s Manual
T-SGPIO1
T-SGPIO2
I-SATA0
COM1
JSD1
LE4
SW1
JPW10
LAN2
LAN1
JL1
JOH1
JSPK1
JPLD1
JI2C2 JI2C1
JPW7
JPW4
JPW3
JVGA1
JPW9
JPW1
Battery
LE1
DM1
JWD1
J30
JPB1
J29
JPL1
JPG1
FAND
FANC
FANB
FANA
FAN4
FAN3
FAN2
FAN1
FANH
FANG
FANF
FANE
JF1
JPW2
JTPM1
JITP0
SXB1B PCI-E 3.0 X16
SXB4 PCI-E 3.0 X16
CPU2
SXB3 PCI-E 3.0 X16
SXB2 PCI-E 3.0 X16
SXB1C
P1-DIMMA1
P1-DIMMA2
P1-DIMMB1
P1-DIMMB2
P2-DIMMG1
P2-DIMMG2
P2-DIMMH1
P2-DIMMH2
P1-DIMMD2
P1-DIMMD1
P1-DIMMC2
P1-DIMMC1
P2-DIMMF2
P2-DIMMF1
P2-DIMME2
P2-DIMME1
CPU1
IPMI LAN
SXB5 PCI-E 3.0 x8 in x16
SXB1A
JPW6 JPW5
I-SATA1
I-SATA2
I-SATA3
I-SATA4
I-SATA5
JBT1
BIOS
PCH
C602J
LAN CTRL
BMC
X9DRG-HF+ Rev. 1.01
CLOSE 1st
OPEN 1st
CLOSE 1st
OPEN 1st
USB0/1
JPME2
JPME1
1. UID Switch
2. Rear UID LED (LE4)
3. Front UID LED
1
Power Button
Blue+ (OH/Fan Fail/ PWR FaiL/UID LED)
1
NIC1 Link LED
Reset Button
2
Power Fail LED
HDD LED
FP PWRLED
Reset
PWR
3.3 V
ID_UID_SW/3/3V Stby
Red+ (Blue LED Cathode)
Ground
Ground
1920
3.3V
X
Ground
NMI
X
NIC2 Link LED
NIC2 Activity LED
NIC1 Activity LED
UnitIdentierSwitch
A Unit Identier (UID) Switch and two LED In-
dicators are located on the motherboard. The
UID Switch is located next to LAN2 port on the
backplane. The Rear UID LED (LE4) is located
next to the UID Switch. The Front Panel UID
LED is located at Pins 7/8 of the Front Control
Panel at JF1. Connect a cable to Pin 8 on JF1
for Front Panel UID LED indication. When you
press the UID switch, both Rear UID LED and
Front Panel UID LED Indicators will be turned
on. Press the UID switch again to turn off both
LED Indicators. These UID Indicators provide
easy identication of a system unit that may
be in need of service.
Note: UID can also be triggered via
IPMI on the motherboard. For more
information on IPMI, please refer to
the IPMI User's Guide posted on our
Website @http://www.supermicro.
com.
UID LED (LE4)
Status
Color/State OS Status
Blue: On Windows OS Unit Identied
Blue: Blinking
Linux OS Unit Identied
1
2
3
Page 45
Chapter 2: Installation
2-21
Power Button
Blue+ (OH/Fan Fail/ PWR FaiL/UID LED)
1
NIC1 Link LED
Reset Button
2
Power Fail LED
HDD LED
FP PWRLED
Reset
PWR
3.3 V
ID_UID_SW/3/3V Stby
Red+ (Blue LED Cathode)
Ground
Ground
1920
3.3V
X
Ground
NMI
X
NIC2 Link LED
NIC2 Activity LED
NIC1 Activity LED
Front Control Panel
JF1 contains header pins for various buttons and indicators that are normally lo-
cated on a control panel at the front of the chassis. These connectors are designed
specically for use with Supermicro's server chassis. See the gure below for the
descriptions of the various control panel buttons and LED indicators. Refer to the
following section for descriptions and pin denitions.
JF1 Header Pins
T-SGPIO1
T-SGPIO2
I-SATA0
COM1
JSD1
LE4
SW1
JPW10
LAN2
LAN1
JL1
JOH1
JSPK1
JPLD1
JI2C2 JI2C1
JPW7
JPW4
JPW3
JVGA1
JPW9
JPW1
Battery
LE1
DM1
JWD1
J30
JPB1
J29
JPL1
JPG1
FAND
FANC
FANB
FANA
FAN4
FAN3
FAN2
FAN1
FANH
FANG
FANF
FANE
JF1
JPW2
JTPM1
JITP0
SXB1B PCI-E 3.0 X16
SXB4 PCI-E 3.0 X16
CPU2
SXB3 PCI-E 3.0 X16
SXB2 PCI-E 3.0 X16
SXB1C
P1-DIMMA1
P1-DIMMA2
P1-DIMMB1
P1-DIMMB2
P2-DIMMG1
P2-DIMMG2
P2-DIMMH1
P2-DIMMH2
P1-DIMMD2
P1-DIMMD1
P1-DIMMC2
P1-DIMMC1
P2-DIMMF2
P2-DIMMF1
P2-DIMME2
P2-DIMME1
CPU1
IPMI LAN
SXB5 PCI-E 3.0 x8 in x16
SXB1A
JPW6 JPW5
I-SATA1
I-SATA2
I-SATA3
I-SATA4
I-SATA5
JBT1
BIOS
PCH C602J
LAN CTRL
BMC
X9DRG-HF+ Rev. 1.01
CLOSE 1st
OPEN 1st
CLOSE 1st
OPEN 1st
USB0/1
JPME2
JPME1
Page 46
2-22
X9DRG-HF+/X9DRG-HTF+ Motherboard User’s Manual
COM1
JSD1
LE4
SW1
JPW10
LAN2
LAN1
JL1
JOH1
JSPK1
JPLD1
JI2C2
JI2C1
JPW7
JPW4
JPW3
JVGA1
JPW9
JPW1
Battery
LE1
DM1
JWD1
J30
JPB1
J29
JPL1
JPG1
FAND
FANC
FANB
FANA
FAN4
FAN3
FAN2
FAN1
FANH
FANG
FANF
FANE
JF1
JPW2
JTPM1
JITP0
SXB1B PCI-E 3.0 X16
SXB4 PCI-E 3.0 X16
CPU2
SXB3 PCI-E 3.0 X16
SXB2 PCI-E 3.0 X16
SXB1C
P1-DIMMA1
P1-DIMMA2
P1-DIMMB1
P1-DIMMB2
P2-DIMMG1
P2-DIMMG2
P2-DIMMH1
P2-DIMMH2
P1-DIMMD2
P1-DIMMD1
P1-DIMMC2
P1-DIMMC1
P2-DIMMF2
P2-DIMMF1
P2-DIMME2
P2-DIMME1
CPU1
IPMI LAN
SXB5 PCI-E 3.0 x8 in x16
SXB1A
JPW6 JPW5
JBT1
BIOS
PCH C602J
LAN CTRL
BMC
X9DRG-HF+ Rev. 1.01
CLOSE 1st
OPEN 1st
CLOSE 1st
OPEN 1st
USB0/1
JPME2
JPME1
Power Button
Blue+ (OH/Fan Fail/ PWR FaiL/UID LED)
1
NIC1 Link LED
Reset Button
2
Power Fail LED
HDD LED
FP PWRLED
Reset
PWR
3.3 V
ID_UID_SW/3/3V Stby
Red+ (Blue LED Cathode)
Ground
Ground
1920
3.3V
X
Ground
NMI
X
NIC2 Link LED
NIC2 Activity LED
NIC1 Activity LED
Power LED
The Power LED connection is located
on pins 15 and 16 of JF1. Refer to the
table on the right for pin denitions.
NMI Button
The non-maskable interrupt button
header is located on pins 19 and 20
of JF1. Refer to the table on the right
for pin denitions.
NMI Button
PinDenitions(JF1)
Pin# Denition
19 Control
20 Ground
Power LED
PinDenitions(JF1)
Pin# Denition
15 3.3V
16 PWR LED
FrontControlPanelPinDenitions
A. NMI
B. PWR LED
A
B
Page 47
Chapter 2: Installation
2-23
Power Button
Blue+ (OH/Fan Fail/ PWR FaiL/UID LED)
1
NIC1 Link LED
Reset Button
2
Power Fail LED
HDD LED
FP PWRLED
Reset
PWR
3.3 V
ID_UID_SW/3/3V Stby
Red+ (Blue LED Cathode)
Ground
Ground
1920
3.3V
X
Ground
NMI
X
NIC2 Link LED
NIC2 Activity LED
NIC1 Activity LED
B
NIC1/NIC2 LED Indicators
The NIC (Network Interface Controller) LED con-
nection for LAN port 1 is located on pins 11 and
12 of JF1, and the LED connection for LAN Port 2
is on Pins 9 and 10. LAN Port 1/2 support Gigabit
LAN on the X9DRG-HF+, 10G LAN on the X9DRG-
HTF+. Attach the NIC LED cables here to display
network activity. Refer to the table on the right for
pin denitions.
C
A. HDD LED/UID Switch
B. NIC1 LED
C. NIC2 LED
A
HDD LED/UID Switch
The HDD/UID LED connection is located on pins
13 and 14 of JF1. Attach a hard drive LED cable
here to display HDD activities, including Serial
ATA activities. Connect a UID switch cable to use
UID switch connection. The front UID switch works
in conjunction with UID LED located at Pins 7/8.
Also refer to Page 2-20 for more UID switch/LED
information. See the table on the right for pin
denitions.
HDD LED/UID Switch
PinDenitions(JF1)
Pin# Denition
13 UID Switch/3,3V
14 HDD Active
T-SGPIO1
T-SGPIO2
I-SATA0
COM1
JSD1
LE4
SW1
JPW10
LAN2
LAN1
JL1
JOH1
JSPK1
JPLD1
JI2C2
JI2C1
JPW7
JPW4
JPW3
JVGA1
JPW9
JPW1
Battery
LE1
DM1
JWD1
J30
JPB1
J29
JPL1
JPG1
FAND
FANC
FANB
FANA
FAN4
FAN3
FAN2
FAN1
FANH
FANG
FANF
FANE
JF1
JPW2
JTPM1
JITP0
SXB1B PCI-E 3.0 X16
SXB4 PCI-E 3.0 X16
CPU2
SXB3 PCI-E 3.0 X16
SXB2 PCI-E 3.0 X16
SXB1C
P1-DIMMA1
P1-DIMMA2
P1-DIMMB1
P1-DIMMB2
P2-DIMMG1
P2-DIMMG2
P2-DIMMH1
P2-DIMMH2
P1-DIMMD2
P1-DIMMD1
P1-DIMMC2
P1-DIMMC1
P2-DIMMF2
P2-DIMMF1
P2-DIMME2
P2-DIMME1
CPU1
IPMI LAN
SXB5 PCI-E 3.0 x8 in x16
SXB1A
JPW6 JPW5
I-SATA1
I-SATA2
I-SATA3
I-SATA4
I-SATA5
JBT1
BIOS
PCH C602J
LAN CTRL
BMC
X9DRG-HF+ Rev. 1.01
CLOSE 1st
OPEN 1st
CLOSE 1st
OPEN 1st
USB0/1
JPME2
JPME1
GLAN1/2 LED
PinDenitions(JF1)
Pin# Denition
9 NIC 2 Act. LED
10 NIC 2 Link LED
11 NIC 1 Act. LED
12 NIC 1 Link LED
Page 48
2-24
X9DRG-HF+/X9DRG-HTF+ Motherboard User’s Manual
T-SGPIO1
T-SGPIO2
I-SATA0
COM1
JSD1
LE4
SW1
JPW10
LAN2
LAN1
JL1
JOH1
JSPK1
JPLD1
JI2C2
JI2C1
JPW7
JPW4
JPW3
JVGA1
JPW9
JPW1
Battery
LE1
DM1
JWD1
J30
JPB1
J29
JPL1
JPG1
FAND
FANC
FANB
FANA
FAN4
FAN3
FAN2
FAN1
FANH
FANG
FANF
FANE
JF1
JPW2
JTPM1
JITP0
SXB1B PCI-E 3.0 X16
SXB4 PCI-E 3.0 X16
CPU2
SXB3 PCI-E 3.0 X16
SXB2 PCI-E 3.0 X16
SXB1C
P1-DIMMA1
P1-DIMMA2
P1-DIMMB1
P1-DIMMB2
P2-DIMMG1
P2-DIMMG2
P2-DIMMH1
P2-DIMMH2
P1-DIMMD2
P1-DIMMD1
P1-DIMMC2
P1-DIMMC1
P2-DIMMF2
P2-DIMMF1
P2-DIMME2
P2-DIMME1
CPU1
IPMI LAN
SXB5 PCI-E 3.0 x8 in x16
SXB1A
JPW6 JPW5
I-SATA1
I-SATA2
I-SATA3
I-SATA4
I-SATA5
JBT1
BIOS
PCH C602J
LAN CTRL
BMC
X9DRG-HF+ Rev. 1.01
CLOSE 1st
OPEN 1st
CLOSE 1st
OPEN 1st
USB0/1
JPME2
JPME1
Power Button
Blue+ (OH/Fan Fail/ PWR FaiL/UID LED)
1
NIC1 Link LED
Reset Button
2
Power Fail LED
HDD LED
FP PWRLED
Reset
PWR
3.3 V
ID_UID_SW/3/3V Stby
Red+ (Blue LED Cathode)
Ground
Ground
1920
3.3V
X
Ground
NMI
X
NIC2 Link LED
NIC2 Activity LED
NIC1 Activity LED
Power Fail LED
The Power Fail LED connection is lo-
cated on pins 5 and 6 of JF1. Refer to the
table on the right for pin denitions.
A. OH/Fail/PWR Fail LED/UID LED
B. Blue LED Cathode
C. PWR Supply Fail
PWR Fail LED
PinDenitions(JF1)
Pin# Denition
5 3.3V
6 PWR Supply Fail
B
A
Overheat (OH)/Fan Fail/PWR Fail/UID LED
Connect an LED cable to pins 7 and 8 of
Front Control Panel to use the Overheat/
Fan Fail/Power Fail and UID LED con-
nections. The Red LED on pin 7 provides
warnings of overheat, fan failure or pow-
er failure. The Blue LED on pin 8 works
as the front panel UID LED indicator.
The Red LED takes precedence over the
Blue LED by default. Refer to the table
on the right for pin denitions.
OH/Fan Fail/ PWR Fail/Blue_UID
LEDPinDenitions(JF1)
Pin# Denition
7 Red_LED-Cathode/OH/Fan Fail/
Power Fail5.5V.SB
8 Blue_UID LED
OH/Fan Fail/PWR Fail
LED Status (Red LED)
State Denition
Off Normal
On Overheat
Flashing Fan Fail
C
Page 49
Chapter 2: Installation
2-25
T-SGPIO1
T-SGPIO2
I-SATA0
COM1
JSD1
LE4
SW1
JPW10
LAN2
LAN1
JL1
JOH1
JSPK1
JPLD1
JI2C2 JI2C1
JPW7
JPW4
JPW3
JVGA1
JPW9
JPW1
Battery
LE1
DM1
JWD1
J30
JPB1
J29
JPL1
JPG1
FAND
FANC
FANB
FANA
FAN4
FAN3
FAN2
FAN1
FANH
FANG
FANF
FANE
JF1
JPW2
JTPM1
JITP0
SXB1B PCI-E 3.0 X16
SXB4 PCI-E 3.0 X16
CPU2
SXB3 PCI-E 3.0 X16
SXB2 PCI-E 3.0 X16
SXB1C
P1-DIMMA1
P1-DIMMA2
P1-DIMMB1
P1-DIMMB2
P2-DIMMG1
P2-DIMMG2
P2-DIMMH1
P2-DIMMH2
P1-DIMMD2
P1-DIMMD1
P1-DIMMC2
P1-DIMMC1
P2-DIMMF2
P2-DIMMF1
P2-DIMME2
P2-DIMME1
CPU1
IPMI LAN
SXB5 PCI-E 3.0 x8 in x16
SXB1A
JPW6 JPW5
I-SATA1
I-SATA2
I-SATA3
I-SATA4
I-SATA5
JBT1
BIOS
PCH C602J
LAN CTRL
BMC
X9DRG-HF+ Rev. 1.01
CLOSE 1st
OPEN 1st
CLOSE 1st
OPEN 1st
USB0/1
JPME2
JPME1
Power Button
The Power Button connection is located
on pins 1 and 2 of JF1. Momentarily
contacting both pins will power on/off
the system. This button can also be con-
gured to function as a suspend button
(with a setting in the BIOS - See Chapter
5). To turn off the power when the system
is in suspend mode, press the button for
4 seconds or longer. Refer to the table on
the right for pin denitions.
Power Button
PinDenitions(JF1)
Pin# Denition
1 Signal
2 Ground
Reset Button
The Reset Button connection is located
on pins 3 and 4 of JF1. Attach it to a
hardware reset switch on the computer
case. Refer to the table on the right for
pin denitions.
Reset Button
PinDenitions(JF1)
Pin# Denition
3 Reset
4 Ground
A. Reset Button
B. PWR Button
A
B
Power Button
Blue+ (OH/Fan Fail/ PWR FaiL/UID LED)
1
NIC1 Link LED
Reset Button
2
Power Fail LED
HDD LED
FP PWRLED
Reset
PWR
3.3 V
ID_UID_SW/3/3V Stby
Red+ (Blue LED Cathode)
Ground
Ground
1920
3.3V
X
Ground
NMI
X
NIC2 Link LED
NIC2 Activity LED
NIC1 Activity LED
Page 50
2-26
X9DRG-HF+/X9DRG-HTF+ Motherboard User’s Manual
T-SGPIO1
T-SGPIO2
I-SATA0
COM1
JSD1
LE4
SW1
JPW10
LAN2
LAN1
JL1
JOH1
JSPK1
JPLD1
JI2C2
JI2C1
JPW7
JPW4
JPW3
JVGA1
JPW9
JPW1
Battery
LE1
DM1
JWD1
J30
JPB1
J29
JPL1
JPG1
FAND
FANC
FANB
FANA
FAN4
FAN3
FAN2
FAN1
FANH
FANG
FANF
FANE
JF1
JPW2
JTPM1
JITP0
SXB1B PCI-E 3.0 X16
SXB4 PCI-E 3.0 X16
CPU2
SXB3 PCI-E 3.0 X16
SXB2 PCI-E 3.0 X16
SXB1C
P1-DIMMA1
P1-DIMMA2
P1-DIMMB1
P1-DIMMB2
P2-DIMMG1
P2-DIMMG2
P2-DIMMH1
P2-DIMMH2
P1-DIMMD2
P1-DIMMD1
P1-DIMMC2
P1-DIMMC1
P2-DIMMF2
P2-DIMMF1
P2-DIMME2
P2-DIMME1
CPU1
IPMI LAN
SXB5 PCI-E 3.0 x8 in x16
SXB1A
JPW6 JPW5
I-SATA1
I-SATA2
I-SATA3
I-SATA4
I-SATA5
JBT1
BIOS
PCH
C602J
LAN CTRL
BMC
X9DRG-HF+ Rev. 1.01
CLOSE 1st
OPEN 1st
CLOSE 1st
OPEN 1st
USB0/1
JPME2
JPME1
Warning: To ensure adequate power supply to your motherboard, be sure to connect
all the power connectors mentioned above to your power supply For proper system
operation.
2-7 Connecting Cables
A. JPW1: 62-pin SMC-Proprietary PWR (Req'd)
B. JPW2: 20-pin SMC-Proprietary PWR (Req'd)
C. JPW9: 38-pin SMC-Proprietary PWR (Req'd)
D. JPW3/4: 12V 8-pin GPU or Intel Xeon Phi PWR
E. JPW6/7: 12V 8-pin GPU or Intel Xeon Phi PWR
F. JPW5: 12V 8-pin Backplane PWR (Req'd)
G. JPW10: 12V/5V 4-pin HDD PWR (Optional)
A
B
C
Power Connectors
To provide adequate power supply to the motherboard, the X9DRG-HF+/-HTF+
contains the following components. See the tables below for 8-pin and 4-pin power
connector pin denitions.
•One (1) SMC-Proprietary 62-pin Power Connector (JPW1),
•One (1) SMC-Proprietary 20-pin Power Connector (JPW2),
•One (1) SMC-Proprietary 38-pin Power Connector (JPW9),
•Four (4) 12V 8-pin Power Connectors (JPW3/4/6/7) for GPU or Intel Xeon Phi
use,
•One (1) 12V 8-pin Power Connector (JPW5) for Backplane use,
•One (1) 12V/5V 4-pin Power Connector (JPW10) for HDD use (Optional)
D
E
F
12V 8-pin PWR
Connector
PinDenitions
Pins Denition
1~3 +12V
4~8 Ground
12V 4-pin Power
Connector
PinDenitions
Pins Denition
1 +12V
2-3 Ground
4 +5V
G
Page 51
Chapter 2: Installation
2-27
T-SGPIO1
T-SGPIO2
I-SATA0
COM1
JSD1
LE4
SW1
JPW10
LAN2
LAN1
JL1
JOH1
JSPK1
JPLD1
JI2C2 JI2C1
JPW7
JPW4
JPW3
JVGA1
JPW9
JPW1
Battery
LE1
DM1
JWD1
J30
JPB1
J29
JPL1
JPG1
FAND
FANC
FANB
FANA
FAN4
FAN3
FAN2
FAN1
FANH
FANG
FANF FANE
JF1
JPW2
JTPM1
JITP0
SXB1B PCI-E 3.0 X16
SXB4 PCI-E 3.0 X16
CPU2
SXB3 PCI-E 3.0 X16
SXB2 PCI-E 3.0 X16
SXB1C
P1-DIMMA1
P1-DIMMA2
P1-DIMMB1
P1-DIMMB2
P2-DIMMG1
P2-DIMMG2
P2-DIMMH1
P2-DIMMH2
P1-DIMMD2
P1-DIMMD1
P1-DIMMC2
P1-DIMMC1
P2-DIMMF2
P2-DIMMF1
P2-DIMME2
P2-DIMME1
CPU1
IPMI LAN
SXB5 PCI-E 3.0 x8 in x16
SXB1A
JPW6 JPW5
I-SATA1
I-SATA2
I-SATA3
I-SATA4
I-SATA5
JBT1
BIOS
PCH
C602J
LAN CTRL
BMC
X9DRG-HF+ Rev. 1.01
CLOSE 1st
OPEN 1st
CLOSE 1st
OPEN 1st
USB0/1
JPME2
JPME1
Chassis Intrusion
A Chassis Intrusion header is located
at JL1 on the motherboard. Attach an
appropriate cable from the chassis to
inform you of a chassis intrusion when
the chassis is opened.
Chassis Intrusion
PinDenitions
Pin# Denition
1 Intrusion Input
2 Ground
C
A. Fan 1
B. Fan 2
C. Fan 3
D. Fan 4
E. Fan A
F. Fan B
G. Fan C
H. Fan D
I. Fan E
J. Fan F
K. Fan G
L. Fan H
M. Chassis Intrusion
D
Fan Headers
This motherboard has twelve fan headers
on the motherboard. Fans 1~4 are for
CPU/system use and Fans A~H for GPU
use. All these 4-pin fans headers are
backward compatible with the traditional
3-pin fans. However, fan speed control
is only available for 4-pin fans via IPMI
thermal management. See the table on
the right for pin denitions.
Fan Header
PinDenitions
Pin# Denition
1 Ground
2 +12V
3 Tachometer
4 Pulse Width
Modulation
G
H
I
J
K
L
E
F
A
B
M
Page 52
2-28
X9DRG-HF+/X9DRG-HTF+ Motherboard User’s Manual
T-SGPIO1
T-SGPIO2
I-SATA0
COM1
JSD1
LE4
SW1
JPW10
LAN2
LAN1
JL1
JOH1
JSPK1
JPLD1
JI2C2
JI2C1
JPW7
JPW4
JPW3
JVGA1
JPW9
JPW1
Battery
LE1
DM1
JWD1
J30
JPB1
J29
JPL1
JPG1
FAND
FANC
FANB
FANA
FAN4
FAN3
FAN2
FAN1
FANH
FANG
FANF FANE
JF1
JPW2
JTPM1
JITP0
SXB1B PCI-E 3.0 X16
SXB4 PCI-E 3.0 X16
CPU2
SXB3 PCI-E 3.0 X16
SXB2 PCI-E 3.0 X16
SXB1C
P1-DIMMA1
P1-DIMMA2
P1-DIMMB1
P1-DIMMB2
P2-DIMMG1
P2-DIMMG2
P2-DIMMH1
P2-DIMMH2
P1-DIMMD2
P1-DIMMD1
P1-DIMMC2
P1-DIMMC1
P2-DIMMF2
P2-DIMMF1
P2-DIMME2
P2-DIMME1
CPU1
IPMI LAN
SXB5 PCI-E 3.0 x8 in x16
SXB1A
JPW6 JPW5
I-SATA1
I-SATA2
I-SATA3
I-SATA4
I-SATA5
JBT1
BIOS
PCH C602J
LAN CTRL
BMC
X9DRG-HF+ Rev. 1.01
CLOSE 1st
OPEN 1st
CLOSE 1st
OPEN 1st
USB0/1
JPME2
JPME1
Serial Ports
A COM port header is located next
to the BMC controller on the mother-
board. See the table on the right for
pin denitions.
Serial COM) Ports
PinDenitions
Pin # Denition Pin # Denition
1 DCD 6 DSR
2 RXD 7 RTS
3 TXD 8 CTS
4 DTR 9 RI
5 Ground 10 N/A
A. COM1
A
Page 53
Chapter 2: Installation
2-29
T-SGPIO1
T-SGPIO2
I-SATA0
COM1
JSD1
LE4
SW1
JPW10
LAN2
LAN1
JL1
JOH1
JSPK1
JPLD1
JI2C2 JI2C1
JPW7
JPW4
JPW3
JVGA1
JPW9
JPW1
Battery
LE1
DM1
JWD1
J30
JPB1
J29
JPL1
JPG1
FAND
FANC
FANB
FANA
FAN4
FAN3
FAN2
FAN1
FANH
FANG
FANF FANE
JF1
JPW2
JTPM1
JITP0
SXB1B PCI-E 3.0 X16
SXB4 PCI-E 3.0 X16
CPU2
SXB3 PCI-E 3.0 X16
SXB2 PCI-E 3.0 X16
SXB1C
P1-DIMMA1
P1-DIMMA2
P1-DIMMB1
P1-DIMMB2
P2-DIMMG1
P2-DIMMG2
P2-DIMMH1
P2-DIMMH2
P1-DIMMD2
P1-DIMMD1
P1-DIMMC2
P1-DIMMC1
P2-DIMMF2
P2-DIMMF1
P2-DIMME2
P2-DIMME1
CPU1
IPMI LAN
SXB5 PCI-E 3.0 x8 in x16
SXB1A
JPW6 JPW5
I-SATA1
I-SATA2
I-SATA3
I-SATA4
I-SATA5
JBT1
BIOS
PCH C602J
LAN CTRL
BMC
X9DRG-HF+ Rev. 1.01
CLOSE 1st
OPEN 1st
CLOSE 1st
OPEN 1st
USB0/1
JPME2
JPME1
A. TPM/Port 80 Header
B. JOH1
TPM Header/Port 80
Trusted Platform Module/Port 80
header, located at JTPM1, provides
TPM support and Port 80 connection.
Use this header to enhance system
performance and data security. See
the table on the right for pin deni-
tions.
TPM/Port 80 Header
PinDenitions
Pin # Denition Pin # Denition
1 LCLK 2 GND
3 LFRAME# 4 <(KEY)>
5 LRESET# 6 +5V (X)
7 LAD3 8 LAD2
9 +3.3V 10 LAD1
11 LAD0 12 GND
13 SMB_CLK(X) 14 SMB_DAT(X)
15 +3V_DUAL 16 SERIRQ
17 GND 18 CLKRUN# (X)
19 LPCPD#(X) 20 LDRQ# (X)
Overheat LED/Fan Fail
The JOH1 header is used to connect
an LED indicator to provide warnings
of chassis overheating and fan failure.
This LED will blink when a fan failure
occurs. Refer to the tables on right for
pin denitions.
Overheat LED
PinDenitions
Pin# Denition
1 P3V3
2 OH Active
Low Signal
OH/Fan Fail LED
Status
State Message
Solid Overheat
Blinking (1Hz) Fan Fail
Blinking (0.25Hz) PWRFail
A
B
Page 54
2-30
X9DRG-HF+/X9DRG-HTF+ Motherboard User’s Manual
T-SGPIO1
T-SGPIO2
I-SATA0
COM1
JSD1
LE4
SW1
JPW10
LAN2
LAN1
JL1
JOH1
JSPK1
JPLD1
JI2C2 JI2C1
JPW7
JPW4
JPW3
JVGA1
JPW9
JPW1
Battery
LE1
DM1
JWD1
J30
JPB1
J29
JPL1
JPG1
FAND
FANC
FANB
FANA
FAN4
FAN3
FAN2
FAN1
FANH
FANG
FANF FANE
JF1
JPW2
JTPM1
JITP0
SXB1B PCI-E 3.0 X16
SXB4 PCI-E 3.0 X16
CPU2
SXB3 PCI-E 3.0 X16
SXB2 PCI-E 3.0 X16
SXB1C
P1-DIMMA1
P1-DIMMA2
P1-DIMMB1
P1-DIMMB2
P2-DIMMG1
P2-DIMMG2
P2-DIMMH1
P2-DIMMH2
P1-DIMMD2
P1-DIMMD1
P1-DIMMC2
P1-DIMMC1
P2-DIMMF2
P2-DIMMF1
P2-DIMME2
P2-DIMME1
CPU1
IPMI LAN
SXB5 PCI-E 3.0 x8 in x16
SXB1A
JPW6 JPW5
I-SATA1
I-SATA2
I-SATA3
I-SATA4
I-SATA5
JBT1
BIOS
PCH
C602J
LAN CTRL
BMC
X9DRG-HF+ Rev. 1.01
CLOSE 1st
OPEN 1st
CLOSE 1st
OPEN 1st
USB0/1
JPME2
JPME1
K
L
A. T-SGPIO1
B. T-SGPIO2
C. JI
2
C1
D. JI
2
C2
T-SGPIO1/2/-S Headers
Two T-SGPIO (Serial-Link General Pur-
pose Input/Output) headers (T-SGPIO1/2)
are located on the motherboard. These
headers support Serial_Link interface for
onboard SATA connections. See the table
on the right for pin denitions.
Note: NC= No Connection
T-SGPIO
PinDenitions
Pin# Denition Pin Denition
1 NC 2 NC
3 Ground 4 Data
5 Load 6 Ground
7 Clock 8 NC
A
B
C
D
SMBus Headers
Twin-pin headers connect SMBus to the
SXB5 PCI-E slot. See the table on the right
for pin denitions.
SMB to SXB5 Slot
PinDenitions
Pin# Denition
Short Connect SMBus to SXB5
Open Disconnect SMBus from SXB5
Page 55
Chapter 2: Installation
2-31
Speaker Header
The speaker header (JSPK1) for an
onboard buzzer can be used to pro-
vide audible indications for various
beep codes. See the table on the
right for pin denitions. Refer to the
layout below for the locations of the
Internal Buzzer.
Speaker Header
PinDenition
Pin# Denitions
Pin 1 Pos. (+) 5V
Pin 2 Neg. (-) Alarm
Speaker
T-SGPIO1
T-SGPIO2
I-SATA0
COM1
JSD1
LE4
SW1
JPW10
LAN2
LAN1
JL1
JOH1
JSPK1
JPLD1
JI2C2
JI2C1
JPW7
JPW4
JPW3
JVGA1
JPW9
JPW1
Battery
LE1
DM1
JWD1
J30
JPB1
J29
JPL1
JPG1
FAND
FANC
FANB
FANA
FAN4
FAN3
FAN2
FAN1
FANH
FANG
FANF FANE
JF1
JPW2
JTPM1
JITP0
SXB1B PCI-E 3.0 X16
SXB4 PCI-E 3.0 X16
CPU2
SXB3 PCI-E 3.0 X16
SXB2 PCI-E 3.0 X16
SXB1C
P1-DIMMA1
P1-DIMMA2
P1-DIMMB1
P1-DIMMB2
P2-DIMMG1
P2-DIMMG2
P2-DIMMH1
P2-DIMMH2
P1-DIMMD2
P1-DIMMD1
P1-DIMMC2
P1-DIMMC1
P2-DIMMF2
P2-DIMMF1
P2-DIMME2
P2-DIMME1
CPU1
IPMI LAN
SXB5 PCI-E 3.0 x8 in x16
SXB1A
JPW6 JPW5
I-SATA1
I-SATA2
I-SATA3
I-SATA4
I-SATA5
JBT1
BIOS
PCH C602J
LAN CTRL
BMC
X9DRG-HF+ Rev. 1.01
CLOSE 1st
OPEN 1st
CLOSE 1st
OPEN 1st
USB0/1
JPME2
JPME1
A
B
DOM Power Connector
A power connector for SATA DOM
(Disk_On_Module) devices is located
at JSD1. Connect an appropriate
cable here to provide backup power
support for your SATA DOM devices
to retain cache data during power
outage. See the table on the right for
pin denitions..
DOM PWR
PinDenitions
Pin# Denition
1 +5V
2 Ground
3 Ground
A. Onboard Speaker Header
B. SATA DOM PWR
Page 56
2-32
X9DRG-HF+/X9DRG-HTF+ Motherboard User’s Manual
T-SGPIO1
T-SGPIO2
I-SATA0
COM1
JSD1
LE4
SW1
JPW10
LAN2
LAN1
JL1
JOH1
JSPK1
JPLD1
JI2C2
JI2C1
JPW7
JPW4
JPW3
JVGA1
JPW9
JPW1
Battery
LE1
DM1
JWD1
J30
JPB1
J29
JPL1
JPG1
FAND
FANC
FANB
FANA
FAN4
FAN3
FAN2
FAN1
FANH
FANG
FANF FANE
JF1
JPW2
JTPM1
JITP0
SXB1B PCI-E 3.0 X16
SXB4 PCI-E 3.0 X16
CPU2
SXB3 PCI-E 3.0 X16
SXB2 PCI-E 3.0 X16
SXB1C
P1-DIMMA1
P1-DIMMA2
P1-DIMMB1
P1-DIMMB2
P2-DIMMG1
P2-DIMMG2
P2-DIMMH1
P2-DIMMH2
P1-DIMMD2
P1-DIMMD1
P1-DIMMC2
P1-DIMMC1
P2-DIMMF2
P2-DIMMF1
P2-DIMME2
P2-DIMME1
CPU1
IPMI LAN
SXB5 PCI-E 3.0 x8 in x16
SXB1A
JPW6 JPW5
I-SATA1
I-SATA2
I-SATA3
I-SATA4
I-SATA5
JBT1
BIOS
PCH
C602J
LAN CTRL
BMC
X9DRG-HF+ Rev. 1.01
CLOSE 1st
OPEN 1st
CLOSE 1st
OPEN 1st
USB0/1
JPME2
JPME1
K
L
2-8 Jumper Settings
Explanation of Jumpers
To modify the operation of the mother-
board, jumpers can be used to choose
between optional settings. Jumpers create
shorts between two pins to change the
function of the connector. Pin 1 is identied
with a square solder pad on the printed
circuit board. See the motherboard layout
pages for jumper locations.
Note: On two pin jumpers,
"Closed" means the jumper is
on and "Open" means the jumper
is off the pins.
Connector
Pins
Jumper
Cap
Setting
Pin 1-2 short
3 2 1
3 2 1
GLAN Enable/Disable
JPL1 enables or disables the LAN Port1/
LAN Port2 on the motherboard. See the
table on the right for jumper settings. The
default setting is Enabled.
LAN Enable
Jumper Settings
Jumper Setting Denition
1-2 Enabled (default)
2-3 Disabled
A. GLAN1/GLAN2 Enable (X9DRG-HF+)
A. TLAN1/TLAN2 Enable (X9DRG-HTF+)
A
Page 57
Chapter 2: Installation
2-33
T-SGPIO1
T-SGPIO2
I-SATA0
COM1
JSD1
LE4
SW1
JPW10
LAN2
LAN1
JL1
JOH1
JSPK1
JPLD1
JI2C2
JI2C1
JPW7
JPW4
JPW3
JVGA1
JPW9
JPW1
Battery
LE1
DM1
JWD1
J30
JPB1
J29
JPL1
JPG1
FAND
FANC
FANB
FANA
FAN4
FAN3
FAN2
FAN1
FANH
FANG
FANF FANE
JF1
JPW2
JTPM1
JITP0
SXB1B PCI-E 3.0 X16
SXB4 PCI-E 3.0 X16
CPU2
SXB3 PCI-E 3.0 X16
SXB2 PCI-E 3.0 X16
SXB1C
P1-DIMMA1
P1-DIMMA2
P1-DIMMB1
P1-DIMMB2
P2-DIMMG1
P2-DIMMG2
P2-DIMMH1
P2-DIMMH2
P1-DIMMD2
P1-DIMMD1
P1-DIMMC2
P1-DIMMC1
P2-DIMMF2
P2-DIMMF1
P2-DIMME2
P2-DIMME1
CPU1
IPMI LAN
SXB5 PCI-E 3.0 x8 in x16
SXB1A
JPW6 JPW5
I-SATA1
I-SATA2
I-SATA3
I-SATA4
I-SATA5
JBT1
BIOS
PCH
C602J
LAN CTRL
BMC
X9DRG-HF+ Rev. 1.01
CLOSE 1st
OPEN 1st
CLOSE 1st
OPEN 1st
USB0/1
JPME2
JPME1
CMOS Clear
JBT1 is used to clear CMOS. Instead of pins, this "jumper" consists of contact pads
to prevent accidental clearing of CMOS. To clear CMOS, use a metal object such
as a small screwdriver to touch both pads at the same time to short the connection.
Always remove the AC power cord from the system before clearing CMOS.
Note 1: For an ATX power supply, you must completely shut down the
system, remove the AC power cord, and then short JBT1 to clear CMOS.
Note 2: Be sure to remove the onboard CMOS Battery before you short
JBT1 to clear CMOS.
Note 3: Clearing CMOS will also clear all passwords.
A. Clear CMOS
B. Watch Dog Enable
Watch Dog Enable/Disable
Watch Dog (JWD1) is a system monitor that will re-
boot the system when a software application hangs.
Close Pins 1-2 to reset the system if an application
hangs. Close Pins 2-3 to generate a non-maskable
interrupt signal for the application that hangs. See
the table on the right for jumper settings. Watch
Dog must also be enabled in the BIOS.
Watch Dog
Jumper Settings
Jumper Setting Denition
Pins 1-2 Reset (default)
Pins 2-3 NMI
Open Disabled
B
A
Page 58
2-34
X9DRG-HF+/X9DRG-HTF+ Motherboard User’s Manual
T-SGPIO1
T-SGPIO2
I-SATA0
COM1
JSD1
LE4
SW1
JPW10
LAN2
LAN1
JL1
JOH1
JSPK1
JPLD1
JI2C2
JI2C1
JPW7
JPW4
JPW3
JVGA1
JPW9
JPW1
Battery
LE1
DM1
JWD1
J30
JPB1
J29
JPL1
JPG1
FAND
FANC
FANB
FANA
FAN4
FAN3
FAN2
FAN1
FANH
FANG
FANF FANE
JF1
JPW2
JTPM1
JITP0
SXB1B PCI-E 3.0 X16
SXB4 PCI-E 3.0 X16
CPU2
SXB3 PCI-E 3.0 X16
SXB2 PCI-E 3.0 X16
SXB1C
P1-DIMMA1
P1-DIMMA2
P1-DIMMB1
P1-DIMMB2
P2-DIMMG1
P2-DIMMG2
P2-DIMMH1
P2-DIMMH2
P1-DIMMD2
P1-DIMMD1
P1-DIMMC2
P1-DIMMC1
P2-DIMMF2
P2-DIMMF1
P2-DIMME2
P2-DIMME1
CPU1
IPMI LAN
SXB5 PCI-E 3.0 x8 in x16
SXB1A
JPW6 JPW5
I-SATA1
I-SATA2
I-SATA3
I-SATA4
I-SATA5
JBT1
BIOS
PCH C602J
LAN CTRL
BMC
X9DRG-HF+ Rev. 1.01
CLOSE 1st
OPEN 1st
CLOSE 1st
OPEN 1st
USB0/1
JPME2
JPME1
A. VGA Enabled
B. BMC Enabled
VGA Enable
Jumper JPG1 allows the user to enable
the onboard VGA connector. The default
setting is 1-2 to enable the connection.
See the table on the right for jumper
settings.
VGA Enable
Jumper Settings
Jumper Setting Denition
1-2 Enabled (Default)
2-3 Disabled
BMC Enable
Jumper JPB1 allows you to enable the
embedded BMC (Baseboard Manage-
ment) Controller to provide IPMI/KVM
support on the motherboard. See the
table on the right for jumper settings.
BMC Enable
Jumper Settings
Jumper Setting Denition
Pins 1-2 BMC Enable
Pins 2-3 Normal (Default)
A
B
Page 59
Chapter 2: Installation
2-35
Management Engine (ME) Recovery
Use Jumper JPME1 to select ME Firm-
ware Recovery mode, which will limit
resource allocation for essential system
operation only in order to maintain nor-
mal power operation and management.
In the single operation mode, online
upgrade will be available via Recovery
mode. See the table on the right for
jumper settings.
ME Recovery
Jumper Settings
Jumper Setting Denition
1-2 Normal (Default)
2-3 ME Recovery
Manufacturer Mode Select
Close Pin 2 and Pin 3 of Jumper JPME2
to bypass SPI ash security and force
the system to operate in the Manufac-
turer mode, allowing the user to ash
the system rmware from a host server
for system setting modications. See the
table on the right for jumper settings.
ME Mode Select
Jumper Settings
Jumper Setting Denition
1-2 Normal (Default)
2-3 Manufacture Mode
A. JPME1
B. JPME2
T-SGPIO1
T-SGPIO2
I-SATA0
COM1
JSD1
LE4
SW1
JPW10
LAN2
LAN1
JL1
JOH1
JSPK1
JPLD1
JI2C2 JI2C1
JPW7
JPW4
JPW3
JVGA1
JPW9
JPW1
Battery
LE1
DM1
JWD1
J30
JPB1
J29
JPL1
JPG1
FAND
FANC
FANB
FANA
FAN4
FAN3
FAN2
FAN1
FANH
FANG
FANF FANE
JF1
JPW2
JTPM1
JITP0
SXB1B PCI-E 3.0 X16
SXB4 PCI-E 3.0 X16
CPU2
SXB3 PCI-E 3.0 X16
SXB2 PCI-E 3.0 X16
SXB1C
P1-DIMMA1
P1-DIMMA2
P1-DIMMB1
P1-DIMMB2
P2-DIMMG1
P2-DIMMG2
P2-DIMMH1
P2-DIMMH2
P1-DIMMD2
P1-DIMMD1
P1-DIMMC2
P1-DIMMC1
P2-DIMMF2
P2-DIMMF1
P2-DIMME2
P2-DIMME1
CPU1
IPMI LAN
SXB5 PCI-E 3.0 x8 in x16
SXB1A
JPW6 JPW5
I-SATA1
I-SATA2
I-SATA3
I-SATA4
I-SATA5
JBT1
BIOS
PCH
C602J
LAN CTRL
BMC
X9DRG-HF+ Rev. 1.01
CLOSE 1st
OPEN 1st
CLOSE 1st
OPEN 1st
USB0/1
JPME2
JPME1
A
B
Page 60
2-36
X9DRG-HF+/X9DRG-HTF+ Motherboard User’s Manual
2-9 Onboard LED Indicators
A. LAN1/2 LEDs
(GLAN1/GLAN2:
X9DRG-HF+,
TLAN1/TLAN2:
X9DRG-HTF+),
B. IPMI LAN LEDs
IPMI Dedicated LAN LEDs
In addition to LAN 1/LAN 2, an IPMI Dedicated
LAN is also located on the I/O Backplane of
the motherboard. The amber LED on the right
indicates activity, while the green LED on the
left indicates the speed of the connection.
See the tables at right for more information.
LAN 1/LAN 2
Link LED Activity LED
IPMI LAN
IPMI LAN Link LED (Left) &
Activity LED (Right)
Color/State Denition
Link (Left) Green: Solid 100 Mbps
Activity (Right) Amber: Blinking Active
LAN LEDs
There are two LAN ports on the motherboard. Each Ethernet LAN port has two
LEDs. The Yellow LED on the right indicates activity. The LED on the left is the Link
LED, which can be green, amber or off to indicate the speed of the connection. See
the tables at right for more information.
Activity LED
10G_(T)LAN Link (X9DRG-HTF+)
LED Settings (Left)
LED Color Denition
Off No Connection,10 Mbps, or 100 Mbps
Amber 1 Gbps
Green 10 Gbps
Link LED
GLAN/10G LAN (TLAN) Activity
LED Settings (Right)
Color Status Denition
Yellow Flashing Active
Rear View (when facing the rear side of the chassis)
A
B
A
B
T-SGPIO1
T-SGPIO2
I-SATA0
COM1
JSD1
LE4
SW1
JPW10
LAN2
LAN1
JL1
JOH1
JSPK1
JPLD1
JI2C2
JI2C1
JPW7
JPW4
JPW3
JVGA1
JPW9
JPW1
Battery
LE1
DM1
JWD1
J30
JPB1
J29
JPL1
JPG1
FAND
FANC
FANB
FANA
FAN4
FAN3
FAN2
FAN1
FANH
FANG
FANF FANE
JF1
JPW2
JTPM1
JITP0
SXB1B PCI-E 3.0 X16
SXB4 PCI-E 3.0 X16
CPU2
SXB3 PCI-E 3.0 X16
SXB2 PCI-E 3.0 X16
SXB1C
P1-DIMMA1
P1-DIMMA2
P1-DIMMB1
P1-DIMMB2
P2-DIMMG1
P2-DIMMG2
P2-DIMMH1
P2-DIMMH2
P1-DIMMD2
P1-DIMMD1
P1-DIMMC2
P1-DIMMC1
P2-DIMMF2
P2-DIMMF1
P2-DIMME2
P2-DIMME1
CPU1
IPMI LAN
SXB5 PCI-E 3.0 x8 in x16
SXB1A
JPW6 JPW5
I-SATA1
I-SATA2
I-SATA3
I-SATA4
I-SATA5
JBT1
BIOS
PCH C602J
LAN CTRL
BMC
X9DRG-HF+ Rev. 1.01
CLOSE 1st
OPEN 1st
CLOSE 1st
OPEN 1st
USB0/1
JPME2
JPME1
GLAN Link (X9DRG-HF+)
LED Settings (Left)
LED Color Denition
Off No Connection,
10 Mbps
Green 100 Mbps
Amber 1 Gbps
Page 61
Chapter 2: Installation
2-37
T-SGPIO1
T-SGPIO2
I-SATA0
COM1
JSD1
LE4
SW1
JPW10
LAN2
LAN1
JL1
JOH1
JSPK1
JPLD1
JI2C2
JI2C1
JPW7
JPW4
JPW3
JVGA1
JPW9
JPW1
Battery
LE1
DM1
JWD1
J30
JPB1
J29
JPL1
JPG1
FAND
FANC
FANB
FANA
FAN4
FAN3
FAN2
FAN1
FANH
FANG
FANF FANE
JF1
JPW2
JTPM1
JITP0
SXB1B PCI-E 3.0 X16
SXB4 PCI-E 3.0 X16
CPU2
SXB3 PCI-E 3.0 X16
SXB2 PCI-E 3.0 X16
SXB1C
P1-DIMMA1
P1-DIMMA2
P1-DIMMB1
P1-DIMMB2
P2-DIMMG1
P2-DIMMG2
P2-DIMMH1
P2-DIMMH2
P1-DIMMD2
P1-DIMMD1
P1-DIMMC2
P1-DIMMC1
P2-DIMMF2
P2-DIMMF1
P2-DIMME2
P2-DIMME1
CPU1
IPMI LAN
SXB5 PCI-E 3.0 x8 in x16
SXB1A
JPW6 JPW5
I-SATA1
I-SATA2
I-SATA3
I-SATA4
I-SATA5
JBT1
BIOS
PCH
C602J
LAN CTRL
BMC
X9DRG-HF+ Rev. 1.01
CLOSE 1st
OPEN 1st
CLOSE 1st
OPEN 1st
USB0/1
JPME2
JPME1
Onboard Power LED
An Onboard Power LED is located at LE1
on the motherboard. When this LED is on,
the system is on. Be sure to turn off the
system and unplug the power cord before
removing or installing components. See
the tables at right for more information.
Onboard PWR LED Indicator (LE1)
LED Settings
LED Color Denition
Off System Off (PWR cable
not connected)
Green System On
Green: Flashing Quickly
ACPI S1 State
Green: Flashing Slowly
ACPI S3 (STR) State
A. PWR LED
B. BMC Heartbeat LED
BMC Heartbeat LED
A BMC Heartbeat LED is located at DM1
on the motherboard. When DM1 is blink-
ing, BMC functions normally. See the
table at right for more information.
BMC Heartbeat LED
Status
Color/State Denition
Green: Blinking
BMC: Normal
A
B
Page 62
2-38
X9DRG-HF+/X9DRG-HTF+ Motherboard User’s Manual
T-SGPIO1
T-SGPIO2
I-SATA0
COM1
JSD1
LE4
SW1
JPW10
LAN2
LAN1
JL1
JOH1
JSPK1
JPLD1
JI2C2
JI2C1
JPW7
JPW4
JPW3
JVGA1
JPW9
JPW1
Battery
LE1
DM1
JWD1
J30
JPB1
J29
JPL1
JPG1
FAND
FANC
FANB
FANA
FAN4
FAN3
FAN2
FAN1
FANH
FANG
FANF FANE
JF1
JPW2
JTPM1
JITP0
SXB1B PCI-E 3.0 X16
SXB4 PCI-E 3.0 X16
CPU2
SXB3 PCI-E 3.0 X16
SXB2 PCI-E 3.0 X16
SXB1C
P1-DIMMA1
P1-DIMMA2
P1-DIMMB1
P1-DIMMB2
P2-DIMMG1
P2-DIMMG2
P2-DIMMH1
P2-DIMMH2
P1-DIMMD2
P1-DIMMD1
P1-DIMMC2
P1-DIMMC1
P2-DIMMF2
P2-DIMMF1
P2-DIMME2
P2-DIMME1
CPU1
IPMI LAN
SXB5 PCI-E 3.0 x8 in x16
SXB1A
JPW6 JPW5
I-SATA1
I-SATA2
I-SATA3
I-SATA4
I-SATA5
JBT1
BIOS
PCH C602J
LAN CTRL
BMC
X9DRG-HF+ Rev. 1.01
CLOSE 1st
OPEN 1st
CLOSE 1st
OPEN 1st
USB0/1
JPME2
JPME1
Rear UID LED
The rear UID LED is located at LE4 on the
backplane. This LED is used in conjunc-
tion with the rear UID switch to provide
easy identication of a system that might
be in need of service. Refer to UID Switch
on Page 2-20 for more information.
A
A. UID LED
Page 63
Chapter 2: Installation
2-39
T-SGPIO1
T-SGPIO2
I-SATA0
COM1
JSD1
LE4
SW1
JPW10
LAN2
LAN1
JL1
JOH1
JSPK1
JPLD1
JI2C2 JI2C1
JPW7
JPW4
JPW3
JVGA1
JPW9
JPW1
Battery
LE1
DM1
JWD1
J30
JPB1
J29
JPL1
JPG1
FAND
FANC
FANB
FANA
FAN4
FAN3
FAN2
FAN1
FANH
FANG
FANF FANE
JF1
JPW2
JTPM1
JITP0
SXB1B PCI-E 3.0 X16
SXB4 PCI-E 3.0 X16
CPU2
SXB3 PCI-E 3.0 X16
SXB2 PCI-E 3.0 X16
SXB1C
P1-DIMMA1
P1-DIMMA2
P1-DIMMB1
P1-DIMMB2
P2-DIMMG1
P2-DIMMG2
P2-DIMMH1
P2-DIMMH2
P1-DIMMD2
P1-DIMMD1
P1-DIMMC2
P1-DIMMC1
P2-DIMMF2
P2-DIMMF1
P2-DIMME2
P2-DIMME1
CPU1
IPMI LAN
SXB5 PCI-E 3.0 x8 in x16
SXB1A
JPW6 JPW5
I-SATA1
I-SATA2
I-SATA3
I-SATA4
I-SATA5
JBT1
BIOS
PCH C602J
LAN CTRL
BMC
X9DRG-HF+ Rev. 1.01
CLOSE 1st
OPEN 1st
CLOSE 1st
OPEN 1st
USB0/1
JPME2
JPME1
Notes:
For more information on SATA HostRAID conguration, please refer to
the Intel SATA HostRAID User's Guide posted on our Website @ http://
www.supermicro.com.
Serial ATA
PinDenitions
Pin# Denition
1 Ground
2 TX_P
3 TX_N
4 Ground
5 RX_N
6 RX_P
7 Ground
A. I-SATA0
B. I-SATA1
C. I-SATA2
D. I-SATA3
E. I-SATA4
F. I-SATA5
Serial ATA Ports
There are two SATA 3.0 Ports
(I-SATA0/1) and four SATA 2.0 ports
(I-SATA2-I-SATA5) on the mother-
board. These ports provide serial-link
signal connections, which are faster
than the connections of Parallel ATA.
See the table on the right for pin
denitions.
2-10 Serial ATA Connections
C
D
E
F
A
B
Page 64
2-40
X9DRG-HF+/X9DRG-HTF+ Motherboard User’s Manual
Notes
Page 65
3-1
Chapter 3: Troubleshooting
Chapter 3
Troubleshooting
3-1 Troubleshooting Procedures
Use the following procedures to troubleshoot your system. If you have followed all
of the procedures below and still need assistance, refer to the ‘Technical Support
Procedures’ and/or ‘Returning Merchandise for Service’ section(s) in this chapter.
Note: Always disconnect the power cord before adding, changing or installing any
hardware components.
Before Power On
1. Make sure that there are no short circuits between the motherboard and
chassis.
2. Disconnect all ribbon/wire cables from the motherboard, including those for
the keyboard and mouse.
3. Remove all add-on cards.
4. Install CPU 1 rst (making sure it is fully seated) and connect the front panel
connectors to the motherboard.
No Power
1. Make sure that there are no short circuits between the motherboard and the
chassis.
2. Make sure that the ATX power connectors are properly connected
3. Check that the 115V/230V switch on the power supply is properly set, if avail-
able.
4. Turn the power switch on and off to test the system, if applicable.
5. The battery on your motherboard may be old. Check to verify that it still sup-
plies ~3VDC. If it does not, replace it with a new one.
Page 66
3-2
X9DRG-HF+/X9DRG-HTF+ Motherboard User’s Manual
No Video
1. If the power is on, but you have no video, remove all the add-on cards and
cables.
2. Use the speaker to determine if any beep codes exist. Refer to Appendix A
for details on beep codes.
System Boot Failure
If the system does not display POST or does not respond after the power is turned
on, check the following:
1. Check for any error beep from the motherboard speaker.
•If there is no error beep, try to turn on the system without DIMM modules in-
stalled. If there is still no error beep, try to turn on the system again with only
one processor installed in CPU Socket#1. If there is still no error beep, replace
the motherboard.
•If there are error beeps, clear the CMOS settings by unplugging the power
cord and contacting both pads on the CMOS Clear Jumper (JBT1). (Refer to
Section 2-8 in Chapter 2.)
2. Remove all components from the motherboard, especially the DIMM mod-
ules. Make sure that the system's power is on, and memory error beeps are
activated.
3. Turn on the system with only one DIMM module installed. If the system
boots, check for bad DIMM modules or slots by following the Memory Errors
Troubleshooting procedure in this Chapter.
LosingtheSystem’sSetupConguration
1. Make sure that you are using a high quality power supply. A poor quality
power supply may cause the system to lose the CMOS setup information.
Refer to Section 2-7 for details on recommended power supplies.
2. The battery on your motherboard may be old. Check to verify that it still sup-
plies ~3VDC. If it does not, replace it with a new one.
3. If the above steps do not x the Setup Conguration problem, contact your
vendor for repairs.
Page 67
3-3
Chapter 3: Troubleshooting
Memory Errors
When a No-Memory Beep Code is issued by the system, check the following:
1. Make sure that the memory modules are compatible with the system and that
the DIMM modules are properly and fully installed. (For memory compatibility,
refer to the Memory Compatibility Chart posted on our Website @ http://www.
supermicro.com.)
2. Check if different speeds of DIMMs have been installed. It is strongly recom-
mended that you use the same RAM speed for all DIMMs in the system.
3. Make sure that you are using the correct type of Registered (RDIMM)/Load
Reduced (LRDIMM) ECC or Unbuffered (UDIMM) ECC/Non-ECC DDR3
800/1066/1333/1600 MHz 4-channel memory modules recommended by the
manufacturer.
4. modules recommended by the manufacturer.
5. Check for bad DIMM modules or slots by swapping a single module among
all memory slots and check the results.
6. Make sure that all memory modules are fully seated in their slots. Follow the
instructions given in Section 2-4 in Chapter 2.
7. Please follow the instructions given in the DIMM Population Tables listed in
Section 2-4 to install your memory modules.
When the System Becomes Unstable
A. The system becomes unstable during or after OS installation
When the system becomes unstable during or after OS installation, check the fol-
lowing:
1. CPU/BIOS support: Make sure that your CPU is supported, and you have the
latest BIOS installed in your system.
2. Memory support: Make sure that the memory modules are supported by test-
ing the modules using memtest86 or a similar utility.
Note: Refer to the product page on our website http://www.supermicro.
com for memory and CPU support and updates.
3. HDD support: Make sure that all hard disk drives (HDDs) work properly. Re-
place the bad HDDs with good ones.
Page 68
3-4
X9DRG-HF+/X9DRG-HTF+ Motherboard User’s Manual
4. System cooling: Check system cooling to make sure that all heatsink fans,
and CPU/system fans, etc., work properly. Check Hardware Monitoring set-
tings in the BIOS to make sure that the CPU and System temperatures are
within the normal range. Also check the front panel Overheat LED, and make
sure that the Overheat LED is not on.
5. Adequate power supply: Make sure that the power supply provides adequate
power to the system. Make sure that all power connectors are connected.
Please refer to our website for more information on minimum power require-
ment.
6. Proper software support: Make sure that the correct drivers are used.
B. The system becomes unstable before or during OS installation
When the system becomes unstable before or during OS installation, check the
following:
1. Source of installation: Make sure that the devices used for installation are
working properly, including boot devices such as CD/DVD disc, CD/DVD-
ROM.
2. Cable connection: Check to make sure that all cables are connected and
working properly.
3. Using minimum conguration for troubleshooting: Remove all unnecessary
components (starting with add-on cards rst), and use minimum conguration
(with a CPU and a memory module installed) to identify the trouble areas.
Refer to the steps listed in Section A above for proper troubleshooting proce-
dures.
4. Identifying bad components by isolating them: If necessary, remove a compo-
nent in question from the chassis, and test it in isolation to make sure that it
works properly. Replace a bad component with a good one.
5. Check and change one component at a time instead of changing several
items at the same time. This will help isolate and identify the problem.
6. To nd out if a component is good, swap this component with a new one to
see if the system will work properly. If so, then the old component is bad.
You can also install the component in question in another system. If the new
system works, the component is good and the old system has problems.
Page 69
3-5
Chapter 3: Troubleshooting
3-2 Technical Support Procedures
Before contacting Technical Support, please take the following steps. Also, please
note that as a motherboard manufacturer, Supermicro also sells motherboards
through its channels, so it is best to rst check with your distributor or reseller for
troubleshooting services. They should know of any possible problem(s) with the
specic system conguration that was sold to you.
1. Please go through the ‘Troubleshooting Procedures’ and 'Frequently Asked
Question' (FAQ) sections in this chapter or see the FAQs on our website
(http://www.supermicro.com/) before contacting Technical Support.
2. BIOS upgrades can be downloaded from our website (http://www.supermicro.
com).
3. If you still cannot resolve the problem, include the following information when
contacting Supermicro for technical support:
•Motherboard model and PCB revision number
•BIOS release date/version (This can be seen on the initial display when your
system rst boots up.)
•System conguration
4. An example of a Technical Support form is on our website at (http://www.
supermicro.com).
•Distributors: For immediate assistance, please have your account number ready
when placing a call to our technical support department. We can be reached by
e-mail at [email protected].
Page 70
3-6
X9DRG-HF+/X9DRG-HTF+ Motherboard User’s Manual
Proper Battery Disposal
Warning: Please handle used batteries carefully. Do not damage the battery in any
way; a damaged battery may release hazardous materials into the environment. Do
not discard a used battery in the garbage or a public landll. Please comply with the
regulations set up by your local hazardous waste management agency to dispose of
your used battery properly.
Battery Installation
1. To install an onboard battery, follow the steps 1& 2 above and continue
below:
2. Identify the battery's polarity. The positive (+) side should be facing up.
3. Insert the battery into the battery holder and push it down until you hear a
click to ensure that the battery is securely locked.
Warning: When replacing a battery, be sure to only replace it with the same type.
3-3 Battery Removal and Installation
Battery Removal
To remove the onboard battery, follow the steps below:
1. Power off your system and unplug your power cable.
2. Locate the onboard battery as shown below.
3. Using a tool such as a pen or a small screwdriver, push the battery lock out-
wards to unlock it. Once unlocked, the battery will pop out from the holder.
4. Remove the battery.
OR
Page 71
3-7
Chapter 3: Troubleshooting
3-4 Frequently Asked Questions
Question: What are the various types of memory that my motherboard can
support?
Answer: The motherboard supports Registered (RDIMM)/Load Reduced (LRDIMM)
ECC or Unbuffered (UDIMM) ECC/Non-ECC DDR3 4-channel memory. To enhance
memory performance, do not mix memory modules of different speeds and sizes.
Please follow all memory installation instructions given on Section 2-4 in Chapter 2.
Question: How do I update my BIOS?
It is recommended that you do not upgrade your BIOS if you are not experiencing
any problems with your system. Updated BIOS les are located on our website
at http://www.supermicro.com. Please check our BIOS warning message and the
information on how to update your BIOS on our website. Select your motherboard
model and download the BIOS le to your computer. Also, check the current BIOS
revision to make sure that it is newer than your BIOS before downloading. You can
choose from the zip le and the .exe le. If you choose the zip BIOS le, please
unzip the BIOS le onto a bootable USB device. Run the batch le using the format
AMI.bat lename.rom from your bootable USB device to ash the BIOS. Then, your
system will automatically reboot.
Warning: Do not shut down or reset the system while updating the BIOS to prevent
possible system boot failure!)
Note: The SPI BIOS chip used on this motherboard cannot be removed.
Send your motherboard back to our RMA Department at Supermicro for
repair. For BIOS Recovery instructions, please refer to the AMI BIOS
Recovery Instructions posted at http://www.supermicro.com.
Question: How do I handle the used battery?
Answer: Please handle used batteries carefully. Do not damage the battery in any
way; a damaged battery may release hazardous materials into the environment. Do
not discard a used battery in the garbage or a public landll. Please comply with the
regulations set up by your local hazardous waste management agency to dispose
of your used battery properly. (Refer to Section 3-3 on Page 3-6.)
Page 72
3-8
X9DRG-HF+/X9DRG-HTF+ Motherboard User’s Manual
3-5 Returning Merchandise for Service
A receipt or copy of your invoice marked with the date of purchase is required before
any warranty service will be rendered. You can obtain service by calling your ven-
dor for a Returned Merchandise Authorization (RMA) number. When returning the
motherboard to the manufacturer, the RMA number should be prominently displayed
on the outside of the shipping carton, and the shipping package is mailed prepaid
or hand-carried. Shipping and handling charges will be applied for all orders that
must be mailed when service is complete. For faster service, You can also request
a RMA authorization online (http://www.supermicro.com).
This warranty only covers normal consumer use and does not cover damages in-
curred in shipping or from failure due to the alternation, misuse, abuse or improper
maintenance of products.
During the warranty period, contact your distributor rst for any product problems.
Page 73
Chapter 4: AMI BIOS
4-1
Chapter 4
BIOS
4-1 Introduction
This chapter describes the AMI BIOS Setup utility for the X9DRG-HF+/X9DRG-
HTF+. It also provides the instructions on how to navigate the AMI BIOS Setup
utility screens. The AMI ROM BIOS is stored in a Flash EEPROM and can be
easily updated.
Starting BIOS Setup Utility
To enter the AMI BIOS Setup utility screens, press the <Del> key while the system
is booting up.
Note: In most cases, the <Del> key is used to invoke the AMI BIOS setup
screen. There are a few cases when other keys are used, such as <F3>,
<F4>, etc.
Each main BIOS menu option is described in this manual. The Main BIOS setup
menu screen has two main frames. The left frame displays all the options that can
be congured. Grayed-out options cannot be congured. Options in blue can be
congured by the user. The right frame displays the key legend. Above the key
legend is an area reserved for informational text related to the option currently
selected in the left frame.
Note: The AMI BIOS has default informational messages built in. The
manufacturer retains the option to include, omit, or change any of these
informational messages.
The AMI BIOS Setup utility uses a key-based navigation system called "hot keys."
Most of the AMI BIOS setup utility "hot keys" can be used at any time during setup
navigation. These keys include <F3>, <F4>, <Enter>, <ESC>, arrow keys, etc.
Note 1: In this section, options printed in Bold are default settings.
Note 2: <F3> is used to load optimal default settings. <F4> is used to save
the settings and exit the setup utility.
Page 74
4-2
X9DRG-HF+/X9DRG-HTF+ Motherboard User’s Manual
HowToChangetheCongurationData
The conguration data that determines the system parameters may be changed by
entering the AMI BIOS Setup utility. This Setup utility can be accessed by pressing
<Delete> at the appropriate time during system boot.
Note: For AMI UEFI BIOS Recovery, please refer to the UEFI BIOS Re-
covery User Guide posted @http://www.supermicro.com/support/manuals/.
Starting the Setup Utility
Normally, the only visible Power-On Self-Test (POST) routine is the memory test.
As the memory is being tested, press the <Delete> key to enter the main menu of
the AMI BIOS Setup utility. From the main menu, you can access the other setup
screens. An AMI BIOS identication string is displayed at the left bottom corner of
the screen below the copyright message.
Warning: Do not upgrade the BIOS unless your system has a BIOS-related issue.
Flashing the wrong BIOS can cause irreparable damage to the system. In no event
shall the manufacturer be liable for direct, indirect, special, incidental, or consequential
damage arising from a BIOS update. If you have to update the BIOS, do not shut down
or reset the system while the BIOS is being updated to avoid possible boot failure.
4-2 Main Setup
When you rst enter the AMI BIOS Setup utility, you will enter the Main setup screen.
You can always return to the Main setup screen by selecting the Main tab on the
top of the screen. The Main BIOS Setup screen is shown below.
The AMI BIOS main menu displays the following information:
Page 75
Chapter 4: AMI BIOS
4-3
System Date
This item displays the system date in Day MM/DD/YY format (e.g. Wed 10/12/2012).
System Time
This item displays the system time in HH:MM:SS format (e.g. 15:32:52).
Supermicro X9DRG-HTF+
Version
This item displays the SMC version of the BIOS ROM used in this system.
Build Date
This item displays the date that the BIOS ROM was built.
Memory Information
Total Memory
This displays the amount of memory that is available in the system.
Page 76
4-4
X9DRG-HF+/X9DRG-HTF+ Motherboard User’s Manual
4-3 AdvancedSetupCongurations
Use the arrow keys to select Advanced Setup and press <Enter> to access the
following submenu items.
Boot Feature
Quiet Boot
This feature allows the user to select the bootup screen display between POST
messages and the OEM logo. Select Disabled to display the POST messages.
Select Enabled to display the OEM logo instead of the normal POST messages.
The options are Enabled and Disabled.
AddOn ROM Display Mode
Use this item to set the display mode for the Option ROM. Select Keep Current to
use the current AddOn ROM Display setting. Select Force BIOS to use the Option
ROM display mode set by the system BIOS. The options are Force BIOS and
Keep Current.
Bootup Num-Lock
Use this feature to set the Power-on state for the Num Lock key. The options are
Off and On.
Wait For 'F1' If Error
Select Enabled to force the system to wait until the 'F1' key is pressed if an error
occurs. The options are Disabled and Enabled.
Page 77
Chapter 4: AMI BIOS
4-5
Interrupt 19 Capture
Interrupt 19 is the software interrupt that handles the boot disk function. When this
item is set to Enabled, the ROM BIOS of the host adaptors will "capture" Interrupt 19
at bootup and allow the drives that are attached to these host adaptors to function
as bootable disks. If this item is set to Disabled, the ROM BIOS of the host adap-
tors will not capture Interrupt 19, and the drives attached to these adaptors will not
function as bootable devices. The options are Enabled and Disabled.
Re-try Boot
When set to Enabled, the BIOS will continuously retry to boot from the selected
boot type. The options are Disabled, Legacy Boot, and EFI Boot.
PowerConguration
Watch Dog Function
If enabled, the Watch Dog timer will allow the system to automatically reboot when
a non-recoverable error occurs that lasts for more than ve minutes. The options
are Enabled and Disabled.
Power Button Function
If this feature is set to Instant Off, the system will power off immediately as soon
as the user presses the power button. If this feature is set to 4 Seconds Override,
the system will power off when the user presses the power button for 4 seconds or
longer. The options are Instant Off and 4 Seconds Override.
Restore on AC Power Loss
Use this feature to set the power state after a power outage. Select Stay Off for the
system power to remain off after a power loss. Select Power On for the system
power to be turned on after a power loss. Select Last State to allow the system
to resume its last state before a power loss. The options are Power On, Stay Off,
and Last State.
CPUConguration
This submenu displays the information of the CPU as detected by the BIOS. It also
allows the user to congure CPU settings.
Page 78
4-6
X9DRG-HF+/X9DRG-HTF+ Motherboard User’s Manual
Socket 1 CPU Information, Socket 2 CPU Information
This submenu displays the following information regarding the CPUs installed in
Socket 1 and Socket 2.
•Type of CPU
•CPU Signature
•Microcode Patch
•CPU Stepping
•Maximum CPU Speed
•Minimum CPU Speed
•Processor Cores
•Intel HT (Hyper-Threading) Technology
•Intel VT-x Technology
•Intel SMX Technology
•L1 Data Cache
•L1 Code Cache
•L2 Cache
•L3 Cache
CPU Speed
This item displays the speed of the CPU installed in the Socket selected.
64-bit
This item indicates if 64-bit technology is supported by the CPU installed in the Socket selected.
Clock Spread Spectrum
Select Enable to enable Clock Spectrum support, which will allow the BIOS to moni-
tor and attempt to reduce the level of Electromagnetic Interference caused by the
components whenever needed. The options are Disabled and Enabled.
Page 79
Chapter 4: AMI BIOS
4-7
RTID (Record Types IDs)
This feature displays the total number of Record Type IDs for local and remote
pools. The options are Optimal and Alternate.
Hyper-threading
Select Enabled to support Intel Hyper-threading Technology to enhance CPU per-
formance. The options are Enabled and Disabled.
Active Processor Cores
Set to Enabled to use a processor's second core and above. (Please refer to Intel's
website for more information.) The options are All, 1, 2, 4, and 6.
Limit CPUID Maximum
This feature allows the user to set the maximum CPU ID value. Enable this function
to boot the legacy operating systems that cannot support processors with extended
CPUID functions. The options are Enabled and Disabled (for the Windows OS).
Execute-Disable Bit (Available if supported by the OS & the CPU)
Select Enabled to enable the Execute Disable Bit which will allow the processor
to designate areas in the system memory where an application code can execute
and where it cannot, thus preventing a worm or a virus from ooding illegal codes
to overwhelm the processor or damage the system during an attack. The default is
Enabled. (Refer to Intel and Microsoft Web sites for more information.)
Intel® AES-NI
Select Enable to use the Intel Advanced Encryption Standard (AES) New Instruc-
tions (NI) to ensure data security. The options are Enabled and Disabled.
MLC Streamer Prefetcher (Available when supported by the CPU)
If set to Enabled, the MLC (mid-level cache) streamer prefetcher will prefetch
streams of data and instructions from the main memory to the L2 cache to improve
CPU performance. The options are Disabled and Enabled.
MLC Spatial Prefetcher (Available when supported by the CPU)
If this feature is set to Disabled, the CPU prefetches the cache line for 64 bytes.
If this feature is set to Enabled the CPU fetches both cache lines for 128 bytes as
comprised. The options are Disabled and Enabled.
DCU Streamer Prefetcher (Available when supported by the CPU)
Select Enabled to support Data Cache Unit (DCU) prefetch of L1 data to speed
up data accessing and processing in the DCU to enhance CPU performance. The
options are Disabled and Enabled.
Page 80
4-8
X9DRG-HF+/X9DRG-HTF+ Motherboard User’s Manual
DCU IP Prefetcher
Select Enabled for DCU (Data Cache Unit) IP Prefetcher support, which will prefetch
IP addresses to improve network connectivity and system performance. The options
are Enabled and Disabled.
Intel® Virtualization Technology (Available when supported by the CPU)
Select Enabled to support Intel Virtualization Technology, which will allow one
platform to run multiple operating systems and applications in independent parti-
tions, creating multiple "virtual" systems in one physical computer. The options
are Enabled and Disabled.
Note: If there is any change to this setting, you will need to power off and
restart the system for the change to take effect. Please refer to Intel’s
website for detailed information.)
 CPUPowerManagementConguration
This submenu allows the user to congure the following CPU Power Management
settings.
Power Technology
Select Energy Efciency to support power-saving mode. Select Custom to cus-
tomize system power settings. Select Disabled to disable power-saving settings. The options are Disabled, EnergyEfcient, and Custom. If the option is set to
Custom, the following items will display:
EIST (Available when Power Technology is set to Custom)
EIST (Enhanced Intel SpeedStep Technology) allows the system to au-
tomatically adjust processor voltage and core frequency to reduce power
consumption and heat dissipation. The options are Disabled and Enabled.
Turbo Mode (Available when Power Technology is set to Custom and EIST is enabled)
This feature allows processor cores to run faster than marked frequency in
specic conditions. The options are Disabled and Enabled.
C1E Support (Available when Power Technology is set to Custom)
Select Enabled to enable Enhanced C1 Power State to boost system per-
formance. The options are Enabled and Disabled.
Page 81
Chapter 4: AMI BIOS
4-9
CPU C3 Report (Available when Power Technology is set to Custom)
Select Enabled to allow the BIOS to report the CPU C3 State (ACPI C2) to
the operating system. During the CPU C3 State, the CPU clock generator
is turned off. The options are Enabled and Disabled.
CPU C6 Report (Available when Power Technology is set to Custom)
Select Enabled to allow the BIOS to report the CPU C6 State (ACPI C3) to
the operating system. During the CPU C6 State, the power to all cache is
turned off. The options are Enabled and Disabled.
CPU C7 Report (Available when Power Technology is set to Custom)
Select Enabled to allow the BIOS to report the CPU C7 State (ACPI C3) to
the operating system. CPU C7 State is a processor-specic low C-State.
The options are Enabled and Disabled.
Package C-State limit (Available when Power Technology is set to
Custom)
This feature allows the user to set the limit on the C-State package register.
The options are C0, C2, C6, and No Limit.
Energy Performance Bias
Use this feature to select an appropriate fan setting to achieve maximum system
performance (with maximum cooling) or maximum energy efciency with maxi-
mum power saving). The fan speeds are controlled by the rmware management
via IPMI 2.0. The options are Performance, Balanced Performance, Balanced
Energy, and Energy Efcient.
Factory Long Duration Power Limit
This item displays the power limit (in watts) set by the manufacturer during which
long duration power is maintained.
Long Duration Power Limit
This item displays the power limit (in watts) set by the user during which long
duration power is maintained. The default setting is 0.
Factory Long Duration Maintained
This item displays the period of time (in seconds) set by the manufacturer during
which long duration power is maintained.
Page 82
4-10
X9DRG-HF+/X9DRG-HTF+ Motherboard User’s Manual
Long Duration Maintained
This item displays the period of time (in seconds) during which long duration
power is maintained. The default setting is 0.
Recommended Short Duration Power Limit
This item displays the short duration power settings (in watts) recommended by
the manufacturer.
Short Duration Power Limit
This item displays the time period during which short duration power (in watts)
is maintained. The default setting is 0.
ChipsetConguration
North Bridge
This feature allows the user to congure the settings for the Intel North Bridge.
IntegratedIOConguration
Intel® VT-d
Select Enabled to enable Intel Virtualization Technology support for Direct I/O VT-d by reporting the I/O device assignments to the VMM (Virtual Machine
Monitor) through the DMAR ACPI Tables. This feature offers fully-protected I/O
resource sharing across Intel platforms, providing greater reliability, security
and availability in networking and data-sharing. The options are Enabled and
Disabled.
Intel® I/OAT
Select Enabled to enable Intel I/OAT (I/O Acceleration Technology), which sig-
nicantly reduces CPU overhead by leveraging CPU architectural improvements
and freeing the system resource for other tasks. The options are Disabled and
Enabled.
DCA Support
When set to Enabled, this feature uses Intel's DCA (Direct Cache Access)
Technology to improve data transfer efciency. The default setting is Enabled.
SXB1 ~ SXB 5 Riser Card
When riser cards are detected on the PCI-E slots by the BIOS, the following
items display riser card information.
Page 83
Chapter 4: AMI BIOS
4-11
CPU1 IIO 1 PCIe Port Bifurcation Control
This submenu congures the following IO PCIe Port Bifurcation Control settings
for the PCIe ports to determine how the available PCI-Express lanes will be
distributed between the PCI-Exp. Root Ports.
CPU1 SXB5 PCI-E 3.0 x8 Link Speed
Use this item to select the desired type of PCI-Exp Generation support for the
slot indicated above. The options are GEN1, GEN2, and GEN3.
CPU1 SXB3 PCI-E 3.0 x16 Link Speed
Use this item to select the desired type of PCI-Exp Generation support for the
slot indicated above. The options are GEN1, GEN2, and GEN3.
CPU1 SXB1 PCI-E 3.0 x16 Link Speed
Use this item to select the desired type of PCI-Exp Generation support for the
slot indicated above. The options are GEN1, GEN2, and GEN3.
CPU2 IIO 2 PCIe Port Bifurcation Control
This submenu congures the following IO PCIe Port Bifurcation Control settings
for the PCIe ports to determine how the available PCI-Express lanes will be
distributed between the PCI-Exp. Root Ports.
CPU2 SXB2 PCI-E 3.0 x16 Link Speed
Use this item to select the desired type of PCI-Exp Generation support for the
slot indicated above. The options are GEN1, GEN2, and GEN3.
CPU2 SXB4 PCI-E 3.0 x16 Link Speed
Use this item to select the desired type of PCI-Exp Generation support for the
slot indicated above. The options are GEN1, GEN2, and GEN3.
QPIConguration
Current QPI Link Speed
This item displays the current status of the QPI Link.
Current QPI Link Frequency
This item displays the frequency of the QPI Link.
Isoc
Select Enabled to enable Isochronous support to meet QoS (Quality of Service)
requirements. This feature is especially important for virtualization technology.
The options are Enabled and Disabled.
Page 84
4-12
X9DRG-HF+/X9DRG-HTF+ Motherboard User’s Manual
QPI (Quick Path Interconnect) Link Speed Mode
Use this feature to select data transfer speed for QPI Link connections. The
options are Fast and Slow.
QPI Link Frequency Select
Use this feature to select the desired QPI frequency. The options are Auto, 6.4
GT/s, 7.2 GT/s, and 8.0 GT/s.
DIMMConguration
This section displays the following DIMM information.
Current Memory Mode
This item displays the current memory mode.
Current Memory Speed
This item displays the current memory speed.
Mirroring
This item displays if memory mirroring is supported by the motherboard. Memory
mirroring creates a duplicate copy of the data stored in the memory to enhance
data security.
Sparing
This item displays if memory sparing is supported by the motherboard. Memory
sparing enhances system performance.
DIMM Information
The status of the memory modules is displayed as detected by the BIOS.
Memory Mode
When Independent is selected, all DIMMs are available to the operating system.
When Mirroring is selected, the motherboard maintains two identical copies of all
data in memory for data backup. When Lockstep is selected, the motherboard
uses two areas of memory to run the same set of operations in parallel. The
options are Independent, Mirroring, and Lockstep.
DRAM RAPL Mode
RAPL (Running Average Power Limit) provides mechanisms to enforce power
consumption limits on supported processors The options are DRAM RAPL
MODE0, DRAM RAPL MODE1, and Disabled.
Page 85
Chapter 4: AMI BIOS
4-13
DDR Speed
Use this feature to force a DDR3 memory module to run at a frequency other
than what is specied by the manufacturer. The options are Auto, Force DDR3-
800, Force DDR3-1066, Force DDR3-1333, Force DDR3-1600 and Force SPD.
Channel Interleaving
This feature selects from the different channel interleaving methods. The options
are Auto, 1 Way, 2 Way, 3, Way, and 4 Way.
Rank Interleaving
This feature allows the user to select a rank memory interleaving method. The
options are Auto, 1 Way, 2 Way, 4, Way, and 8 Way.
Patrol Scrub
Patrol Scrubbing is a process that allows the CPU to correct correctable memory
errors detected on a memory module and send the correction to the requestor
(the original source). When this item is set to Enabled, the IO hub will read and
write back one cache line every 16K cycles, if there is no delay caused by internal
processing. By using this method, roughly 64 GB of memory behind the IO hub
will be scrubbed every day. The options are Enabled and Disabled.
Demand Scrub
Demand Scrubbing is a process that allows the CPU to correct correctable
memory errors found on a memory module. When the CPU or I/O issues a
demand-read command, and the read data from memory turns out to be a
correctable error, the error is corrected and sent to the requestor (the original
source). Memory is updated as well. Select Enabled to use Demand Scrubbing
for ECC memory correction. The options are Enabled and Disabled.
Data Scrambling
Select Enabled to enable data scrambling to ensure data security and integrity.
The options are Disabled and Enabled.
Device Tagging
Select Enabled to support device tagging. The options are Disabled and En-
abled.
Thermal Throttling
Throttling improves reliability and reduces power consumption in the proces-
sor via automatic voltage control during processor idle states. The options are
Disabled and CLTT (Closed Loop Thermal Throttling).
Page 86
4-14
X9DRG-HF+/X9DRG-HTF+ Motherboard User’s Manual
SouthBridgeConguration
This feature allows the user to congure the settings for the Intel PCH chip.
PCH Information
This feature displays the following PCH information.
Name: This item displays the name of the PCH chip.
Stepping: This item displays the PCH stepping.
USB Devices: This item displays the USB devices detected by the BIOS.
All USB Devices
This feature enables all USB ports/devices. The options are Disabled and Enabled.
EHCI Controller 1, EHCI Controller 2 (Available when All USB Devices is set to Enabled)
Select Enabled to enable EHCI (Enhanced Host Controller Interface) Controller 1
or Controller 2. The options are Disabled and Enabled.
Legacy USB Support (Available when USB Functions is not Disabled)
Select Enabled to support legacy USB devices. Select Auto to disable legacy sup-
port if USB devices are not present. Select Disabled to have USB devices available
for EFI (Extensive Firmware Interface) applications only. The settings are Disabled,
Enabled and Auto.
Port 60/64 Emulation
Select Enabled to enable I/O port 60h/64h emulation support for the legacy USB
keyboard so that it can be fully supported by the operating systems that does not
recognize a USB device. The options are Disabled and Enabled.
EHCI Hand-Off
This item is for operating systems that do not support Enhanced Host Controller
Interface (EHCI) hand-off. When enabled, EHCI ownership change will be claimed
by the EHCI driver. The options are Disabled and Enabled.
SATAConguration
When this submenu is selected, the AMI BIOS automatically detects the presence
of IDE or SATA devices and displays the following items.
SATA Port0~SATA Port5: The AMI BIOS displays the status of each SATA port
as detected by the BIOS.
Page 87
Chapter 4: AMI BIOS
4-15
SATA Mode
Use this feature to congure SATA mode for a selected SATA port. The options are
Disabled, IDE Mode, AHCI Mode and RAID Mode. The following are displayed
depending on your selection:
IDE Mode
The following items are displayed when IDE Mode is selected:
Serial-ATA (SATA) Controller 0~1
Use this feature to activate or deactivate the SATA controller, and set the
compatibility mode. The options are Disabled, Enhanced, and Compatible.
The default for SATA Controller 0 is Compatible. The default of SATA Con-
troller 1 is Enhanced.
AHCI Mode
The following items are displayed when the AHCI Mode is selected.
Aggressive Link Power Management
When Enabled, the SATA AHCI controller manages the power usage of
the SATA link. The controller will put the link in a low power mode during
extended periods of I/O inactivity, and will return the link to an active state
when I/O activity resumes. The options are Enabled and Disabled.
Port 0~5 Hot Plug
Select Enabled to enable hot-plug support for a particular port, which will
allow the user to change a hardware component or device without shutting
down the system. The options are Enabled and Disabled.
Port 0~5 Staggered Spin Up
Select Enabled to enable Staggered Spin-up support to prevent excessive
power consumption caused by multiple HDDs spinning-up simultaneously.
The options are Enabled and Disabled.
RAID Mode
The following items are displayed when RAID Mode is selected:
Onboard SATA RAID Oprom/Driver
Use this feature to enable the onboard SATA Option ROM or EFI driver. The
options are Enabled and Disabled.
Page 88
4-16
X9DRG-HF+/X9DRG-HTF+ Motherboard User’s Manual
Port 0~5 Hot Plug
Select Enabled to enable hot-plug support for the particular port. The options
are Disabled and Enabled.
PCIe/PCI/PnPConguration
Launch Storage OpROM Policy
Use this feature to select the Option ROM to boot the system when there are multiple
Option ROMs available in the system. The options are UEFI only and Legacy only.
PCI Latency Timer
Use this feature to set the latency Timer of each PCI device installed on a PCI bus.
Select 64 to set the PCI latency to 64 PCI clock cycles. The options are 32, 64, 96,
128, 160, 192, 224 and 248.
PERR# Generation
Select Enabled to allow a PCI device to generate a PERR number for a PCI Bus
Signal Error Event. The options are Enabled and Disabled.
SERR# Generation
Select Enabled to allow a PCI device to generate an SERR number for a PCI Bus
Signal Error Event. The options are Enabled and Disabled.
Maximum Payload
Select Auto to allow the system BIOS to automatically set the maximum payload
value for a PCI-E device to enhance system performance. The options are Auto,
128 Bytes, and 256 Bytes.
Maximum Read Request
Select Auto to allow the system BIOS to automatically set the maximum Read
Request size for a PCI-E device to enhance system performance. The options are
Auto, 128 Bytes, 256 Bytes, 512 Bytes, 1024 Bytes, 2048 Bytes, and 4096 Bytes.
ASPM Support
This feature allows the user to set the Active State Power Management (ASPM)
level for a PCI-E device. Select Auto to allow the system BIOS to automatically
set the ASPM level for the system. Select Disabled to disable ASPM support. The
options are Disabled, Auto, and Force L0s.
Warning: Enabling ASPM support may cause some PCI-E devices to fail!
Page 89
Chapter 4: AMI BIOS
4-17
Above 4G Decoding (Available if the system supports 64-bit PCI decoding)
Select Enabled to decode a PCI device that supports 64-bit in the space above 4G
Address. The options are Enabled and Disabled.
SXB1 PCI-E x16 OPROM, SXB2 PCI-E x16 OPROM, SXB3 PCI-E x16 OPROM, SXB4 PCI-E x16 OPROM, SXB5 PCI-E x8 OPROM,
Select Enabled to enable Option ROM support to boot the computer using a de-
vice installed on the slot specied above. The options are Enabled and Disabled.
Onboard LAN Option ROM Select
Select iSCSI to use the iSCSI Option ROM to boot the computer using a network
device. Select PXE (Preboot Execution Environment) to use an PXE Option ROM
to boot the computer using a network device. The options are iSCSI and PXE.
Load Onboard LAN1 Option ROM, Load Onboard LAN2 Option ROM
Select Enabled to enable the onboard LAN1/LAN2 Option ROM. This is to boot
the computer using a network device. The default setting for LAN1 Option ROM is
Enabled, and the default setting for LAN2 Option ROM is Disabled.
Load Onboard SAS OPROM
Select Enabled to enable the onboard SAS Option ROM. This is to boot the com-
puter using a SAS device. The options are Disabled and Enabled.
VGA Priority
This feature allows the user to select the graphics adapter to be used as the primary
boot device. The options are Onboard, and Offboard.
Network Stack
Select Enabled enable PXE (Preboot Execution Environment) or UEFI (Unied
Extensible Firmware Interface) for network stack support. The options are Enabled
and Disabled.
IPv4 PXE Support (Available when Network Stack is set to Enabled)
Set this item to Enabled to activate IPv4 PXE Support. The options are Enabled
and Disabled.
IPv6 PXE Support (Available when Network Stack is set to Enabled)
Set this item to Enabled to activate IPv6 PXE Support. The options are Enabled
and Disabled.
Page 90
4-18
X9DRG-HF+/X9DRG-HTF+ Motherboard User’s Manual
SuperIOConguration
Super IO Chip: This item displays the Super IO chip used in the motherboard.
SerialPort1Conguration
Serial Port
Select Enabled to enable a serial port specied by the user. The options are En-
abled and Disabled.
Device Settings
This item displays the settings of Serial Port 1.
Change Settings
This option species the base I/O port address and the Interrupt Request address
of Serial Port 1. Select Disabled to prevent the serial port from accessing any
system resources. When this option is set to Disabled, the serial port becomes
unavailable. The options are Auto, IO=3F8h; IRQ=4, IO=3F8h; IRQ=3, IO=2F8h;
IRQ=3, IO=3E8h; IRQ=5, IO=2E8h; IRQ=7, IO=3F8h; IRQ=3, 4, 5, 6, 7, 10, 11,
12; IO=2F8h; IRQ=3, 4, 5, 6, 7, 10, 11, 12; IO=3E8h; IRQ=3, 4, 5, 6, 7, 10, 11, 12;
IO=2E8h; IRQ=3, 4, 5, 6, 7, 10, 11, 12;
Device Mode
Use this feature to select the desired mode for a serial port specied. The options
are Normal and High Speed.
SerialPort2Conguration
Serial Port
Select Enabled to enable a serial port specied by the user. The options are En-
abled and Disabled.
Device Settings
This item displays the settings of Serial Port 2.
Change Settings
This option species the base I/O port address and the Interrupt Request address
of Serial Port 2. Select Disabled to prevent the serial port from accessing any
system resources. When this option is set to Disabled, the serial port becomes
unavailable. The options are Auto, IO=3F8h; IRQ=4, IO=3F8h; IRQ=3, IO=2F8h;
Page 91
Chapter 4: AMI BIOS
4-19
IRQ=3, IO=3E8h; IRQ=5, IO=2E8h; IRQ=7, IO=3F8h; IRQ=3, 4, 5, 6, 7, 10, 11,
12; IO=2F8h; IRQ=3, 4, 5, 6, 7, 10, 11, 12; IO=3E8h; IRQ=3, 4, 5, 6, 7, 10, 11, 12;
IO=2E8h; IRQ=3, 4, 5, 6, 7, 10, 11, 12;
Device Mode
Use this feature to select the desired mode for a serial port specied. The options
are Normal and High Speed.
Serial Port 2 Attribute
Use this feature to select the attribute for serial port 2. The options are SOL (Serial
On LAN), and COM.
Serial Port Console Redirection
COM1, COM2
These two submenus allow the user to congure the following Console Redirection
settings for a COM Port specied by the user.
COM1, COM2 Console Redirection
Select Enabled to use a COM Port selected by the user for Console Redirection.
The options are Enabled and Disabled. The default setting for COM1 is Disabled,
and for COM2 is Enabled.
Console Redirection Settings
This feature allows the user to specify how the host computer will exchange data
with the client computer, which is the remote computer used by the user.
Terminal Type
This feature allows the user to select the target terminal emulation type for Con-
sole Redirection. Select VT100 to use the ASCII Character set. Select VT100+ to
add color and function key support. Select ANSI to use the Extended ASCII Char-
acter Set. Select VT-UTF8 to use UTF8 encoding to map Unicode characters
into one or more bytes. The options are ANSI, VT100, VT100+, and VT-UTF8.
Bits Per second
Use this feature to set the transmission speed for a serial port used in Console
Redirection. Make sure that the same speed is used in the host computer and the
client computer. A lower transmission speed may be required for long and busy
lines. The options are 9600, 19200, 38400, 57600 and 115200 (bits per second).
Page 92
4-20
X9DRG-HF+/X9DRG-HTF+ Motherboard User’s Manual
Data Bits
Use this feature to set the data transmission size for Console Redirection. The
options are 7 Bits and 8 Bits.
Parity
A parity bit can be sent along with regular data bits to detect data transmission
errors. Select Even if the parity bit is set to 0, and the number of 1's in data bits
is even. Select Odd if the parity bit is set to 0, and the number of 1's in data bits
is odd. Select None if you do not want to send a parity bit with your data bits
in transmission. Select Mark to add a mark as a parity bit to be sent along with
the data bits. Select Space to add a Space as a parity bit to be sent with your
data bits. The options are None, Even, Odd, Mark and Space.
Stop Bits
A stop bit indicates the end of a serial data packet. Select 1 Stop Bit for standard
serial data communication. Select 2 Stop Bits if slower devices are used. The
options are 1 and 2.
Flow Control
This feature allows the user to set the ow control for Console Redirection to
prevent data loss caused by buffer overow. Send a "Stop" signal to stop send-
ing data when the receiving buffer is full. Send a "Start" signal to start sending
data when the receiving buffer is empty. The options are None and Hardware
RTS/CTS.
VT-UTF8 Combo Key Support
Select Enabled to enable VT-UTF8 Combination Key support for ANSI/VT100
terminals. The options are Enabled and Disabled.
Recorder Mode
Select Enabled to capture the data displayed on a terminal and send it as text
messages to a remote server. The options are Disabled and Enabled.
Resolution 100x31
Select Enabled for extended-terminal resolution support. The options are Dis-
abled and Enabled.
Legacy OS Redirection Resolution
Use this feature to select the number of rows and columns used in Console
Redirection for legacy OS support. The options are 80x24 and 80x25.
Page 93
Chapter 4: AMI BIOS
4-21
Putty KeyPad
This feature selects Function Keys and KeyPad settings for Putty, which is a
terminal emulator designed for the Windows OS. The options are VT100, LINUX,
XTERMR6, SCO, ESCN, and VT400.
Redirection After BIOS Post
Use this feature to enable or disable legacy console redirection after BIOS POST.
When set to Bootloader, legacy console redirection is disabled before booting
the OS. When set to Always Enable, legacy console redirection remains enabled
when booting the OS. The options are Always Enable and Bootloader.
Serial Port for Out-of-Band Management/Windows Emergency Management Services (EMS)
The submenu allows the user to congure Console Redirection settings to support
Out-of-Band Serial Port management.
Console Redirection
Select Enabled to use a COM Port selected by the user for Console Redirection.
The options are Enabled and Disabled.
Console Redirection Settings (for EMS)
This feature allows the user to specify how the host computer will exchange
data with the client computer, which is the remote computer used by the user.
Out-of-Band Management Port
The feature selects a serial port used by the Microsoft Windows Emergency
Management Services (EMS) to communicate with a remote server. The options
are COM1 and COM2.
Terminal Type
This feature allows the user to select the target terminal emulation type for Con-
sole Redirection. Select VT100 to use the ASCII character set. Select VT100+
to add color and function key support. Select ANSI to use the extended ASCII
character set. Select VT-UTF8 to use UTF8 encoding to map Unicode characters
into one or more bytes. The options are ANSI, VT100, VT100+, and VT-UTF8.
Bits Per Second
This item sets the transmission speed for a serial port used in Console Redirec-
tion. Make sure that the same speed is used in the host computer and the client
computer. A lower transmission speed may be required for long and busy lines.
The options are 9600, 19200, 57600, and 115200 (bits per second).
Page 94
4-22
X9DRG-HF+/X9DRG-HTF+ Motherboard User’s Manual
Flow Control
This feature allows the user to set the ow control for Console Redirection to
prevent data loss caused by buffer overow. Send a "Stop" signal to stop send-
ing data when the receiving buffer is full. Send a "Start" signal to start sending
data when the receiving buffer is empty. The options are None, Hardware RTS/
CTS, and Software Xon/Xoff.
Data Bits, Parity, Stop Bits
The setting for each of these items is displayed.
ACPI Settings
Use this feature to congure Advanced Conguration and Power Interface (ACPI)
power management settings for your system.
ACPI Sleep State
Use this feature to select the ACPI State when the system is in sleep mode. Select
S1 (CPU Stop Clock) to erase all CPU caches and stop executing instructions.
Power to the CPU(s) and RAM is maintained, but RAM is refreshed. Select Sus-
pend Disabled to use power-reduced mode. Power will only be supplied to limited
components (such as RAMs) to maintain the most critical functions of the system.
The options are S1 (CPU Stop Clock), and Suspend Disabled.
NUMA (NON-Uniform Memory Access)
This feature enables the Non-Uniform Memory Access ACPI support. The options
are Enabled and Disabled.
High Precision Event Timer
Select Enabled to activate the High Precision Event Timer (HPET) that produces
periodic interrupts at a much higher frequency than a Real-time Clock (RTC) does
in synchronizing multimedia streams, providing smooth playback, reducing the de-
pendency on other timestamp calculation devices, such as an x86 RDTSC Instruc-
tion embedded in the CPU. The High Performance Event Timer is used to replace
the 8254 Programmable Interval Timer. The options are Enabled and Disabled.
Page 95
Chapter 4: AMI BIOS
4-23
Trusted Computing (Available when a TPM device is detected by the BIOS)
Conguration
TPM Support
Select Enabled on this item and enable the TPM jumper on the motherboard to
enable TPM support to improve data integrity and network security. The options
are Enabled and Disabled.
TPM State
Select Enabled to enable TPM security settings to improve data integrity and
network security. The options are Disabled and Enabled.
Pending Operation
Use this item to schedule an operation for the security device. The options are
None, Enable Take Ownership, Disable Take Ownership, and TPM Clear.
Note: During restart, the computer will reboot in order to execute the pend-
ing operation and change the state of the security device.
Current Status Information: This item displays the information regarding the
current TPM status.
TPM Enable Status
This item displays the status of TPM Support to indicate if TPM is currently
enabled or disabled.
TPM Active Status
This item displays the status of TPM Support to indicate if TPM is currently ac-
tive or deactivated.
TPM Owner Status
This item displays the status of TPM Ownership.
Page 96
4-24
X9DRG-HF+/X9DRG-HTF+ Motherboard User’s Manual
IntelTXT(LT-SX)Conguration
Intel TXT (LT-SX) Hardware Support
This feature indicates if the following hardware components support the Intel
Trusted Execution Technology.
CPU: TXT (Trusted Execution Technology) Feature
Chipset: TXT (Trusted Execution Technology) Feature
IntelTXT(LT-SX)Conguration
This feature displays the following TXT conguration setting.
TXT (LT-SX) Support: This item indicates if the Intel TXT support is enabled
or disabled. The default setting is Disabled.
Note: Be sure to format your TPM module before enabling TXT (LT-SX)
support for this feature to work properly.
Intel TXT (LT-SX) Dependencies
For Trusted Execution Technology to work properly, be sure to enable the fea-
tures displayed below:
VT-d Support: Intel Virtualization Technology with Direct I/O support
VT Support: Intel Virtualization Technology support
TPM Support: Trusted Platform support
TPM State: Trusted Platform state
ME Subsystem
This feature displays the following ME Subsystem Conguration settings.
•ME BIOS Interface Version
•ME Version
Page 97
Chapter 4: AMI BIOS
4-25
4-4 Event Logs
Use this feature to congure Event Log settings.
Change SMBIOS Event Log Settings
This feature allows the user to congure SMBIOS Event settings.
Enabling/Disabling Options
SMBIOS Event Log
Select Enabled to enable SMBIOS (System Management BIOS) Event Logging
during system boot. The options are Enabled and Disabled.
Runtime Error Logging Support
Select Enabled to support Runtime Error Logging. The options are Enabled and
Disabled.
Memory Correctable Error Threshold
This feature allows the user to enter the threshold value for correctable memory
errors. The default setting is 10.
PCI Error Logging Support
Select Enabled to support error event logging for PCI slots. The options are Enabled
and Disabled.
Page 98
4-26
X9DRG-HF+/X9DRG-HTF+ Motherboard User’s Manual
Erasing Settings
Erase Event Log
Select Enabled to erase the SMBIOS (System Management BIOS) Event Log, which
is completed before an event logging is initialized upon system reboot. The options
are No, Yes, next reset, and Yes, every reset.
When Log is Full
Select Erase Immediately to immediately erase SMBIOS error event logs that ex-
ceed the limit when the SMBIOS event log is full. Select Do Nothing for the system
to do nothing when the SMBIOS event log is full. The options are Do Nothing and
Erase Immediately.
SMBIOS Event Log Standard Settings
Log System Boot Event
Select Enabled to log system boot events. The options are Disabled and Enabled.
MECI (Multiple Event Count Increment)
Enter the increment value for the multiple event counter. Enter a number between
1 to 255. The default setting is 1.
METW (Multiple Event Count Time Window)
This item allows the user to decide how long (in minutes) should the multiple event
counter wait before generating a new event log. Enter a number between 0 to 99.
The default setting is 60.
View SMBIOS Event Log
This item allows the user to view the event in the SMBIOS event log. Select this
item and press <Enter> to view the status of an event in the log.
Page 99
Chapter 4: AMI BIOS
4-27
4-5 IPMI
Use this feature to congure Intelligent Platform Management Interface (IPMI)
settings.
IPMI Firmware Revision
This item indicates the IPMI rmware revision used in your system.
IPMI Status
This item indicates the status of the IPMI rmware installed in your system.
System Event Log
Enabling/Disabling Options
SEL Components
Select Enabled for all system event logging at bootup. The options are Enabled
and Disabled.
Erasing Settings
Erase SEL
Select Yes, On next reset to erase all system event logs upon next system reboot.
Select Yes, On every reset to erase all system event logs upon each system reboot.
Select No to keep all system event logs after each system reboot. The options are
No, Yes, On next reset, and Yes, On every reset.
Page 100
4-28
X9DRG-HF+/X9DRG-HTF+ Motherboard User’s Manual
When SEL is Full
This feature allows the user to decide what the BIOS should do when the system
event log is full. Select Erase Immediately to erase all events in the log when the
system event log is full. The options are Do Nothing and Erase Immediately.
Custom EFI Logging Options
Log EFI Status Codes
Select Enabled to log EFI (Extensible Firmware Interface) Status Codes, Error
Codes or Progress Codes. The options are Enabled and Disabled.
Note: After making changes on a setting, be sure to reboot the system for
the changes to take effect.
BMCNetworkConguration
LAN Channel 1: This feature allows the user to congure the settings for the
LAN1 Port.
UpdateIPMILANConguration
This feature allows the BIOS to implement any IP/MAC address changes at the next
system boot. If the option is set to Yes, any changes made to the settings below will
take effect when the system is rebooted. The options are No and Yes.
CongurationAddressSource
This feature allows the user to select the source of the IP address for this computer.
If Static is selected, you will need to know the IP address of this computer and enter
it to the system manually in the eld. If DHCP is selected, the BIOS will search for a
DHCP (Dynamic Host Conguration Protocol) server in the network that it is attached
to and request the next available IP address for this computer. The options for are
DHCP and Static. The following items are assigned IP addresses automatically if
DHCP is selected, or can be congured manually if Static is selected.
Station IP Address
This item displays the Station IP address for this computer. This should be in decimal
and in dotted quad form (i.e., 192.168.10.253).
Subnet Mask
This item displays the sub-network that this computer belongs to. The value of each
three-digit number separated by dots should not exceed 255.
Station MAC Address
This item displays the Station MAC address for this computer. Mac addresses are
6 two-digit hexadecimal numbers.
Loading...