Supero X8DTH-6, X8DTH-iF, X8DTH-i, X8DTH-6F User Manual

Page 1
X8DTH-6
X8DTH-6F X8DTH-i X8DTH-iF
USER’S MANUAL
Revision 1.0
Page 2
The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccuracies that may be contained in this document, makes no commitment to update or to keep current the information in this manual, or to notify any person or organization of the updates. Please Note: For the most up-to-date version of this
manual, please see our website at www.supermicro.com.
Super Micro Computer, Inc. ("Supermicro") reserves the right to make changes to the product described in this manual at any time and without notice. This product, including software, if any, and documentation may not, in whole or in part, be copied, photocopied, reproduced, translated or reduced to any medium or machine without prior written consent.
IN NO EVENT WILL SUPERMICRO BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL, SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO USE THIS PRODUCT OR DOCUMENTATION, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. IN PARTICULAR, SUPERMICRO SHALL NOT HAVE LIABILITY FOR ANY HARDWARE, SOFTW ARE, OR DA TA STORED OR USED WITH THE PRODUCT, INCLUDING THE COSTS OF REPAIRING, REPLACING, INTEGRATING, INSTALLING OR RECOVERING SUCH HARDWARE, SOFTWARE, OR DATA.
Any disputes arising between manufacturer and customer shall be governed by the laws of Santa Clara County in the State of California, USA. The State of California, County of Santa Clara shall be the exclusive venue for the resolution of any such disputes. Super Micro's total liability for all claims will not exceed the price paid for the hardware product.
FCC Statement: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the manufacturer’s instruction manual, may cause harmful interference with radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case you will be required to correct the interference at your own expense.
California Best Management Practices Regulations for Perchlorate Materials: This Perchlorate warning applies only to products containing CR (Manganese Dioxide) Lithium coin cells. “Perchlorate Material-special handling may apply. See www.dtsc.ca.gov/hazardouswaste/perchlorate”
WARNING: Handling of lead solder materials used in this product may expose you to lead, a chemical known to the State of California to cause birth defects and other reproductive harm.
Manual Revision 1.0 Release Date: May 14, 2009
Unless you request and receive written permission from Super Micro Computer, Inc., you may not copy any part of this document.
Information in this document is subject to change without notice. Other products and companies referred to herein are trademarks or registered trademarks of their respective companies or mark holders.
Copyright © 2009 by Super Micro Computer, Inc. All rights reserved.
Printed in the United States of America
Page 3
Preface
About this Manual
This manual is written for system integrators, PC technicians and knowledgeable PC users. It provides information for the installation and use of the X8DTH-6F/X8DTH-i/X8DTH-iF motherboard.
About this Motherboard
The X8DTH-6/X8DTH-6F/X8DTH-i/X8DTH-iF supports the Intel® 5500 Series Processor, the fi rst dual-processor platform that supports the Intel QuickPath Interconnect (QPI) Technology, providing the next generation point-to-point system interface to replace the current Front Side Bus. With the dual Intel 5520 chips built in, the X8DTH-6/X8DTH-6F/X8DTH-i/X8DTH-iF offers substantial enhancement in system performance with increased bandwidth and unprecedented scalability op­timized for High Performance Computing (HPC)/Clustering systems and intensive applications. Please refer to our website (http://www.supermicro.com/products/) for updates on supported processors. This product is intended to be installed and serviced by professional technicians.
X8DTH-6/
Preface
Manual Organization
Chapter 1 describes the features, speci cations and performance of the mother-
board and provides detailed information about the chipset. Chapter 2 provides hardware installation instructions. Read this chapter when in-
stalling the processor, memory modules and other hardware components into the system. If you encounter any problems, see Chapter 3, which describes trouble­shooting procedures for video, memory and system setup stored in the CMOS.
Chapter 4 includes an introduction to the BIOS and provides detailed information on running the CMOS Setup utility.
Appendix A lists BIOS POST Error Codes. Appendix B and Appendix C provide the Windows OS and Other Software Installation Instructions.
Conventions Used in the Manual
Special attention should be given to the following symbols for proper installation and to prevent damage done to the components or injury to yourself:
Danger/Caution: Instructions to be strictly followed to prevent catastrophic system failure or to avoid bodily injury.
iii
Page 4
X8DTH-6/X8DTH-6F/X8DTH-i/X8DTH-iF User's Manual
Warning: Important information given to ensure proper system installation or to prevent damage to the components.
Note: Additional Information given to differentiate various models or to ensure correct system setup.
iv
Page 5
Contacting Supermicro
Contacting Supermicro
Headquarters
Address: Super Micro Computer, Inc.
980 Rock Ave. San Jose, CA 95131 U.S.A.
Tel: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: marketing@supermicro.com (General Information)
support@supermicro.com (Technical Support)
Website: www.supermicro.com
Europe
Address: Super Micro Computer B.V.
Het Sterrenbeeld 28, 5215 ML 's-Hertogenbosch, The Netherlands
Tel: +31 (0) 73-6400390 Fax: +31 (0) 73-6416525 Email: sales@supermicro.nl (General Information)
support@supermicro.nl (Technical Support) rma@supermicro.nl (Customer Support)
Asia-Pacifi c
Address: Super Micro Computer, Inc.
4F, No. 232-1, Liancheng Rd. Chung-Ho 235, Taipei County Taiwan, R.O.C.
Tel: +886-(2) 8226-3990 Fax: +886-(2) 8226-3991 Website: www.supermicro.com.tw Technical Support: Email: support@supermicro.com.tw Tel: 886-2-8228-1366, ext.132 or 139
v
Page 6
X8DTH-6/X8DTH-6F/X8DTH-i/X8DTH-iF User's Manual
Table of Contents
Preface ...........................................................................................................3
About this Manual ......................................................................................................... 3
About this Motherboard ................................................................................................. 3
Manual Organization ..................................................................................................... 3
Conventions Used in the Manual .................................................................................. 3
Contacting Supermicro .................................................................................................. 5
Chapter 1 Introduction ................................................................................1
1-1 Overview .........................................................................................................1-1
Checklist ..........................................................................................................1-1
X8DTH-6/X8DTH-6F/X8DTH-i/X8DTH-iF Quick Reference ............................ 1-5
Motherboard Features ...................................................................................1-6
1-3 Chipset Overview ............................................................................................1-9
Main Features of the 5500 Series Processor and the 5520 Chipset .............1-9
1-4 Special Features ........................................................................................... 1-10
Recovery from AC Power Loss ..................................................................... 1-10
1-5 PC Health Monitoring .................................................................................... 1-10
Fan Status Monitor with Firmware Control ..................................................1-10
Environmental Temperature Control .............................................................1-10
System Resource Alert ................................................................................. 1-10
1-6 ACPI Features ................................................................................................1-11
Slow Blinking LED for Suspend-State Indicator ............................................1-11
Main Switch Override Mechanism .................................................................1-11
1-7 Power Supply .................................................................................................1-11
1-8 Super I/O ....................................................................................................... 1-12
1-9 Overview of the Winbond WPCM450 Controller (For X8DTH-6F/iF Only) ...1-12
Chapter 2 Installation .................................................................................1
2-1 Static-Sensitive Devices .................................................................................. 2-1
Precautions .....................................................................................................2-1
Unpacking .......................................................................................................2-1
2-2 Motherboard Installation .................................................................................. 2-2
Tools Needed .................................................................................................. 2-2
Installation Instructions ....................................................................................2-2
2-3 Processor and Heatsink Installation................................................................2-3
Installing a CPU Heatsink ............................................................................... 2-5
2-4 Memory Installation ........................................................................................ 2-7
2-5 Control Panel Connectors/IO Ports...............................................................2-10
vi
Page 7
Table of Contents
1. Back Panel Connectors/IO Ports .............................................................. 2-10
ATX PS/2 Keyboard and PS/2 Mouse Ports .............................................2-11
Serial Ports ............................................................................................... 2-12
Video Connector .......................................................................................2-12
Universal Serial Bus (USB) ...................................................................... 2-13
Ethernet Ports .......................................................................................... 2-14
2. Front Control Panel ...................................................................................2-15
3. Front Control Panel Pin Defi nitions .......................................................... 2-16
NMI Button ............................................................................................... 2-16
Power LED .............................................................................................. 2-16
HDD LED .................................................................................................. 2-17
NIC1/NIC2 LED Indicators ....................................................................... 2-17
Overheat (OH)/Fan Fail LED....................................................................2-18
Power Fail LED ........................................................................................2-18
Reset Button ........................................................................................... 2-19
Power Button ........................................................................................... 2-19
2-6 Connecting Cables ........................................................................................ 2-20
Power Connectors ...................................................................................2-20
Fan Headers ............................................................................................. 2-21
Chassis Intrusion .....................................................................................2-21
Power LED/Speaker ................................................................................. 2-22
Overheat LED/Fan Fail (JOH1) ................................................................2-23
SATA-SGPIO 0/1 Headers ....................................................................... 2-23
System Management Bus ........................................................................ 2-24
Power SMB (I
2
C) Connector .................................................................... 2-24
2-7 Jumper Settings ............................................................................................ 2-25
Explanation of Jumpers ................................................................................ 2-25
GLAN Enable/Disable ..............................................................................2-25
CMOS Clear ............................................................................................. 2-26
Watch Dog Enable/Disable ...................................................................... 2-26
2
I
C Bus to PCI-Exp. Slots ........................................................................ 2-27
VGA Enable .............................................................................................. 2-27
SAS Enable (X8DTH-6/6F Only) ..............................................................2-28
2-8 Onboard LED Indicators ............................................................................... 2-29
GLAN LEDs .............................................................................................. 2-29
IPMI Dedicated LAN LEDs (X8DTH-iF/6F) .............................................. 2-29
BMC Activity LED (X8DTH-iF/6F) ............................................................ 2-30
SAS Activity LED (X8DTH-6/6F) .............................................................. 2-30
SAS Heartbeat LED (X8DTH-6/6F) .......................................................... 2-31
vii
Page 8
X8DTH-6/X8DTH-6F/X8DTH-i/X8DTH-iF User's Manual
SAS Error LED (X8DTH-6/6F) ................................................................. 2-31
Onboard Power LED ............................................................................... 2-32
2-9 SATA and SAS Connections ......................................................................... 2-33
SATA/SAS Connections (SAS: X8DTH-6/6F) .......................................... 2-33
Chapter 3 Troubleshooting ........................................................................1
3-1 Troubleshooting Procedures ........................................................................... 3-1
Before Power On ............................................................................................ 3-1
No Power ........................................................................................................ 3-1
No Video ......................................................................................................... 3-2
Losing the System’s Setup Confi guration ....................................................... 3-2
Memory Errors ...............................................................................................3-2
3-2 Technical Support Procedures ........................................................................3-3
3-3 Frequently Asked Questions ........................................................................... 3-3
3-4 Returning Merchandise for Service.................................................................3-4
Chapter 4 BIOS ............................................................................................ 1
4-1 Introduction ...................................................................................................... 4-1
Starting BIOS Setup Utility ..............................................................................4-1
How To Change the Confi guration Data ......................................................... 4-1
Starting the Setup Utility ................................................................................. 4-2
4-2 Main Setup ......................................................................................................4-2
4-3 Advanced Setup Confi gurations...................................................................... 4-4
4-4 Security Settings ...........................................................................................4-23
4-5 Boot Confi guration ........................................................................................4-24
4-7 BIOS Recovery ............................................................................................. 4-28
How to Recover the AMIBIOS Image (Main BIOS Block) ............................ 4-28
4.7.1 Boot Sector Recovery from a USB Device ..........................................4-28
4.7.2 Boot Sector Recovery from an IDE CD-ROM ..................................... 4-29
4.7.3 Boot Sector Recovery from a Serial Port ("Serial Flash") ................... 4-29
Appendix A BIOS Error Beep Codes ......................................................... 1
Appendix B Installing the Windows OS ................................................... 1
B-1 Installing the Windows OS to a RAID System ................................................ B-1
B-2 Installing the Windows OS to a Non-RAID System ........................................B-2
Appendix C Software Installation Instructions ........................................1
C-1 Installing Software Programs ......................................................................... C-1
C-2 Confi guring Supero Doctor III ......................................................................... C-2
viii
Page 9
Chapter 1: Introduction
Chapter 1
Introduction
1-1 Overview
Checklist
Congratulations on purchasing your computer motherboard from an acknowledged leader in the industry. Supermicro boards are designed with the utmost attention to detail to provide the highest standards in quality and performance. Check that the following items have all been included with your motherboard. If anything listed here is damaged or missing, contact your retailer.
The following items are included in the retail box.
One (1) Supermicro Mainboard
One (1) COM port cable (CBL-010L)
One (1) USB 2.0 cable (CBL-0083L)
Six (6) Serial ATA cables (CBL-0044L) (X8DTH-i/iF)
Four (4) Serial ATA cables (CBL-0044L) (X8DTH-6/6F)
Two (2) iPass to SATA cables (CBL-0097L-02) (X8DTH-6/6F)
One I/O backpanel shield (MCP-260-00027-0N)
One (1) Supermicro CD containing drivers and utilities
One (1) User's/BIOS Manual (MNL#1083)
1-1
Page 10
X8DTH-6/X8DTH-6F/X8DTH-i/X8DTH-iF User's Manual
X8DTH-6/X8DTH-6F/X8DTH-i/X8DTH-iF Image
Note: The drawings and pictures shown in this manual were based on the
latest PCB Revision available at the time of publishing of the manual. The motherboard you’ve received may or may not look exactly the same as the graphics shown in the manual.
1-2
Page 11
Chapter 1: Introduction
COM1
VGA
USB0/1
LAN1
LAN2
DP5
JPL1
FAN5
KB/MS
PHY
LAN CTRL
BMC
IPMI_LAN
FAN8
FAN6
JPG1
JI2C2
Slot7 PCI-E 2.0 X8
Slot6 PCI-E 2.0 X8
Slot5 PCI-E 2.0 X8
JI2C1
Slot4 PCI-E 2.0 X8
Slot3 PCI-E 2.0 X8
Slot2 PCI-E 2.0 X8
Slot1 PCI-E 2.0 X8
JPB
X8DTH-6/X8DTH-6F/X8DTH-i/X8DTH-iF Layout
P2-DIMM3A
P2-DIMM3B
P2-DIMM2A
P2-DIMM2B
P2-DIMM1A
P2-DIMM1B
CPU2
USB6/7
USB4/5
(South Bridge)
USB3
(IOH36D-2)
Intel
ICH10R
SATA-SGPIO1
SATA-SGPIO0
J7
JPI2C
P1-DIMM1B
P1-DIMM1A
P1-DIMM2B
P1-DIMM2A
P1-DIMM3B
P1-DIMM3A
Intel
5520
JBT1
SAS Activity
SPI BIOS
I-SATA5
I-SATA3
I-SATA2
I-SATA1
I-SATA4
JPW1
CPU1
Intel
5520
(IOH36D-1)
LED5
DP6
X8DTH
Rev. 1.01
J*
DP7
JPS1
I-SATA0
LSI SAS2008
RAID Key
JPW2
JPW3
SAS
FLASH
PWR_LED
Battery
SAS0~3
SAS4~7
FAN4
FAN1
FAN7
JF1
DP4
JWD
FAN2
SMBus1
JOH1
JD1
FAN3
Buzzer
JL1
Differences between X8DTH-6/X8DTH-6F/X8DTH-i/X8DTH-iF
X8DTH-6 X8DTH-6F X8DTH-i X8DTH-iF
SATA2 (ICH10R) Yes Yes Yes Yes
LSI SAS2.0 2008 Controller Yes Yes No No
IPMI 2.0 w/KVM No Yes No Yes
Notes
IPMI 2.0, Winbond Hermon WPCM450 Controller, the PHY chip and Dedicated
LAN port w/KVM support are available on the X8DTH-6F/iF only . For more infor­mation, refer to the user guide posted on our website @ http://www.supermicro. com/support/manuals/,
SAS2.0, LSI SAS2.0 2008 Controller, SAS Ports 0~7 are available on the
X8DTH-6/6F only. For more information on LSI RAID Confi guration, refer to the LSI user guide posted on our website @ http://www.supermicro.com/sup­port/manuals/
1-3
Page 12
X8DTH-6/X8DTH-6F/X8DTH-i/X8DTH-iF User's Manual
Quick Reference
COM1
VGA
USB0/1
LAN1
LAN2
DP5
JPL1
FAN5
KB/MS
PHY
LAN CTRL
BMC
IPMI_LAN
FAN8
FAN6
JPG1
JI2C2
Slot7 PCI-E 2.0 X8
Slot6 PCI-E 2.0 X8
Slot5 PCI-E 2.0 X8
JI2C1
Slot4 PCI-E 2.0 X8
Slot3 PCI-E 2.0 X8
Slot2 PCI-E 2.0 X8
Slot1 PCI-E 2.0 X8
JPB
P2-DIMM3A
P2-DIMM3B
P2-DIMM2A
P2-DIMM2B
P2-DIMM1A
P2-DIMM1B
CPU2
USB6/7
USB4/5
(South Bridge)
USB3
(IOH36D-2)
Intel
ICH10R
SATA-SGPIO1
SATA-SGPIO0
J7
JPI2C
Intel
5520
JBT1
SPI BIOS
I-SATA5
I-SATA3
I-SATA4
I-SATA2
P1-DIMM1B
P1-DIMM1A
P1-DIMM2B
P1-DIMM2A
P1-DIMM3B
P1-DIMM3A
Intel
(IOH36D-1)
LED5
SAS Activity
I-SATA1
JPW1
CPU1
X8DTH
Rev. 1.01
5520
DP6
DP7
JPS1
I-SATA0
J*
LSI SAS2008
RAID Key
JPW2
JPW3
SAS
FLASH
PWR_LED
Battery
SAS0~3
SAS4~7
FAN4
FAN1
FAN7
JF1
DP4
JWD
FAN2
SMBus1
JOH1
JD1
FAN3
Buzzer
JL1
Notes
Jumpers not indicated are for test purposes only. 1. " " indicates the location of Pin 1.2. When DP4 is on, the onboard power connection is on. Make sure to unplug 3.
the power cables before removing or installing components.
Warning! 1. To prevent damage to the power supply or motherboard, please use a power supply that contains a 24-pin and two 8-pin power connectors. Be sure to connect these connectors to the 24-pin (JPW1) and the two 8-pin (JPW2,JPW3) power connectors on the motherboard. Failure in doing so will void the manufacturer warranty on your power supply and motherboard.
2. To avoid system overheating, be sure to provide adequate air fl ow to the system.
1-4
Page 13
Chapter 1: Introduction
X8DTH-6/X8DTH-6F/X8DTH-i/X8DTH-iF Quick Reference
Jumper Description Default Setting
JBT1 CMOS Clear Open (Normal)
2
C1/JI2C2 SMB to PCI/PCI-E Slots Closed/Closed (Enabled)
JI
JPG1 VGA Enable Pins 1-2 (Enabled)
JPL1 LAN1/2 Enable Pins 1-2 (Enabled)
JPS1 SAS2.0 Enable Pins 1-2 (Enabled) (X8DTH-6/-6F only)
JWD Watch Dog Pins 1-2 (Reset)
Connector Description
Buzzer Onboard Buzzer/Internal Speaker
(SPI) BIOS Onboard BIOS
COM1 Backplane Serial Port
FAN 1-8 System/CPU Fan Headers (Fans 7~8: CPU Fans)
JD1 PWR LED/Speaker Header (Pins 1~3: PWR LED, Pins 4~7:
Speaker) JF1 Front Panel Connector JL1 Chassis Intrusion Header JOH1 Overheat LED Header
2
C Power Supply SMBbus I2C Header
JPI JPW1, JPW2/JPW3 24-pin ATX PWR, 8-pin Secondary PWR (See the Warning
on Page 1-4) KB/MS PS2 Keyboard/Mouse LAN1/2, Dedicated LAN G-LAN (RJ45) Ports (Dedicated LAN: X8DTH-6F/iF) I-SATA0 ~ I-SATA5 (Intel South Bridge) SATA Ports SAS Ports 0~3, 4~7 SAS Ports 0~3, 4~7 (X8DTH-6/6F only) SMBUS1 System Management Bus Header SATA-SGPIO-0/SATA-
Serial General Purpose I/O Headers for SATA SGPIO-1
USB 0/1, 3, 4/5, 6/7 Universal Serial Bus (USB) Ports VGA VGA Con nec tor
LED Description
DP4 O nboa rd St andby Pow er LED LE D Indi cato r (Powe r LED) DP5 B MC Ac tiv it y LED Ind ic ator DP6 SAS Heartbeat LED Indicator: green (X8DTH-6/ X8DTH-6F only) DP7 SAS Error LED Indicator: red (X8DTH-6/ X8DTH-6F only) LED5 SAS Act ivi ty LE D Indi cat or (X8DTH-6/ X8DTH-6F only)
1-5
Page 14
X8DTH-6/X8DTH-6F/X8DTH-i/X8DTH-iF User's Manual
Motherboard Features
CPU
Two Intel full-width Intel QuickPath Interconnect (QPI) @6.4 GT/s with a total of up to 51.2 GB/s Data Transfer Rate (6.4 GT/s per direction)
®
5500 Series (LGA 1366) processors, each processor supporting two
Memory
12 240-pin DIMM sockets support up to 96 GB of Registered ECC or up to 24 GB of Unbuffered ECC/Non-ECC DDR3 1333/1066/800 MHz Memory (See Section 2-4 in Chapter 2 for DIMM Slot Population.)
Chipset
Intel 5520 chipset, including: two IOH-36D hubs One ICH10R (South Bridge).
Expansion Slots
Seven PCI-E 2.0 x8 slots (all in x16 slots: Slot 1~Slot 7)
BIOS
32 Mb AMI SPI Flash ROM PCI 2.2, ACPI 1.0/2.0/3.0, Plug and Play (PnP), DMI 2.3, USB Keyboard sup-
port, and SMBIOS 2.3
PC Health Monitoring
Onboard voltage monitors for CPU1 Vcore, CPU2 Vcore, CPU1 Vtt, CPU2 Vtt, CPU1 DIMM, CPU2 DIMM, 1.1V, 1.5V, 1.8V, 3.3V, 12V, 5V, 3.3 Vsb, and VBAT
Fan status monitor with fi rmware control
CPU/chass is temper ature moni tors Platfo rm Enviro nment Co ntrol Inte rf ace (PECI) read y Ther mal Mo nitor 2 ( TM2) supp or t CPU fan auto - of f in sle ep mode CPU slow- dow n on tempe rature over heat Pulse Wi dth Mo dulati on (PW M) Fan Contr ol CPU ther mal tr ip supp or t for pro ces sor pr otecti on, power L ED Power-up mod e cont rol for r ecover y fr om AC power l oss Auto- switc hing vol tage r egulato r for CPU c ore s System over heat /Fan Fail LED I ndic ator and c ontr ol Chassis i ntrus ion detec tion System re sourc e aler t vi a Super o Doc tor III
1-6
Page 15
Chapter 1: Introduction
ACPI Features
Slow blinking LED for suspend state indicator Main switch override mechanism ACPI Pow er Ma nag eme nt
Onboard I/O
Intel ICH10R supports six SATA2 ports (with RAID0, RAID1, RAID10, RAID5 supported in the Windows OS Environment and RAID0, RAID1, RAID10 sup­ported in the Linux OS.) (Note 1)
Intel 82576 Gi gabit Eth ernet c ontr oller su ppor ts du al Gig a-b it L AN po rt s
One VGA Por t supp or ted by the W inbon d Herm on WPC M45 0 Cont rolle r One CO M por t PS/2 mo use and PS /2 keyboa rd por ts Up to seven US B 2.0 (Univers al Serial Bus) (2 Back panel USB Por ts and 5
Front Panel Ac ces sible U SB co nnec tions) Super I/ O: Winbo nd W83 527HG
LSI SAS2 2008 Controller supports eight SAS ports (X8DTH-6/X8DTH-6F only) (Note 2) IPMI 2.0 w ith fu ll K VM supp or t (X8DT H- 6 F/iF only) (Note 3)
Other
Console redirection Onboa rd Fan Spee d Contr ol by Ther mal Ma nagem ent via BI OS
CD/Diskette Utilities
BIOS fl ash upgrade utility and device drivers
Dimensions
Ext . ATX 12.00" (L) x 13.00 " (W ) (304. 80 mm x 3 30. 20 mm)
Note 1: For more information on SATA HostRAID confi guration, please refer to the Intel SATA HostRAID User's Guide posted on our website @ http://www.supermicro.com/support/manuals/.
Note 2: For more information on IPMI confi guration, please refer to the Embedded IPMI User's Guide posted on our website @ http://www.super­micro.com/support/manuals/.
1-7
Page 16
X8DTH-6/X8DTH-6F/X8DTH-i/X8DTH-iF User's Manual
#6
#5
#4
PCI-E X8 in X16 Slot
PCI-E X8 in X16 Slot
PCI-E X8 in X16 Slot
#1-5
#1-4
#1-3
#1-2
#1-1
DDR3
800/1066/1333
PCI-E X8
#7
PCI-E X8
PCI-E X8
PCI-E X8
PCI-E X8 in X16 Slot
#1-6
Ports 1&2
Ports 3&4
Ports 5&6
Ports 7&8
Ports 9&10
BIOS
PROCESSOR#2
(5500 Series)
QPI
Intel 5520
IOH2-36D
SPI
QPI
1
QPI
Intel
ICH10R
PROCESSOR#1
(5500 Series)
00
0
Intel 5520
IOH1-36D
U3H1
ESI
ESI X4
ESI
QPI
#0-3
#0-2
#0-1
DDR3
Ports 3&4
Ports 5&6
Ports 7&8
Ports 9&10
Ports 1&2
SATA2
USB2.0
PCI-E X8
PCI-E X8
PCI-E X8
PCI-E X8
PCI-E X4
#5
#4
#3
#2
#1
#0
SATA
6 FRONT
USB
2 REAR+4 FRONT+ 1 TYPE A
#0-6
#0-5
#0-4
800/1066/1333
#1
PCI-E X8 in X16 Slot
LSI SAS2008
6Gb/s
Optional
LAN
#3
#2
PCI-E X8 in X16 Slot
PCI-E X8 in X16 Slot
0, 1, 2, 3
Intel 82576
LAN2
LAN1
RMII_IPMI
4, 5, 6, 7
VGA
LPC BUS
COM1
External
SIO
W83527HG
U25
MS
KB
LAN3
IPMI_LAN
RTL8201N
PCI 33MHz
RMII IPMI
USB
WPCM450
BMC
DDR II
Block Diagram of the Intel 5520 Platform
Note: This is a general block diagram. Please see the previous Mother-
board Features pages for details on the features of each motherboard.
1-8
Page 17
Chapter 1: Introduction
1-3 Chipset Overview
Built upo n the fun ction ality a nd the ca pabilit y of the Inte l 550 0 Seri es Proc esso r and the 5 520 c hips et, th e X8DTH -6/X8 DTH - 6 F/X8 DTH -i / X8 DTH -i F mot her boa rd provides the performance and feature set required for dual-processor-based high- end systems opt imized for High Per formanc e Computing ( HPC)/Clusterin g severs. T he Intel 5520 chip set consists of d ual 5520 IO hubs, a nd an ICH10R (South Br idg e). With the Inte l Qui ck Path Inte rco nne ct (QPI) c ontr olle r buil t in, th e Intel 55 00 S eri es Pro ces sor is t he fi rst dual-p roc essi ng plat fo rm to of fer t he nex t generation point-to-point system interconnect interface to replace the current Front Side Bus Technology, substantially enhancing system performance and scalability.
The 552 0 IO Hub co nnects to e ach proc essor t hrough an i ndepend ent QPI link. Each link consists of 20 pairs of unidirectional differential lanes for transmission and receiving in addition to a dif ferential for warded clock. A full-width QPI link pair provides 84 signals.
The Intel 5520 supp o rts u p to 36 PCI E x p r ess Gen 2 l a n e s , p e e r-to- p e e r r e a d a n d write transactions. The ICH10R provides up to seven PCI-Express ports, six SATA por ts and s even USB c onne cti ons.
In addition, the Intel 5520 chipset also offers a wide range of R AS (Reliability, Availability and Se rvic e abi li t y) featu re s. T he se f eat ur es i nc l ud e me mo ry interfac e ECC, x4/x8 Single Device Data Correction (SDDC), Cyclic Redundancy Check (CRC), parity pr otec tio n, out- o f- band re gist er ac ces s via S M Bus, me mory mir ro r­ing, memo ry s pari ng, and Ho t-pl ug suppo rt o n the PCI - Ex press I nter face.
Main Features of the 5500 Series Processor and the 5520 Chipset
Four processor cores in each processor with 8MB shared cache among cores
Two full-width Intel QPI links, up to 6.4 GT/s of data transfer rate in each direc- tion
Virtualization Technology, Integrated Management Engine supported
Point-to-point cache coherent interconnect, Fast/narrow unidirectional links, and Concurrent bi-directional traffi c
Error detection via CRC and Error correction via Link level retry
1-9
Page 18
X8DTH-6/X8DTH-6F/X8DTH-i/X8DTH-iF User's Manual
1-4 Special Features
Recovery from AC Power Loss
BIOS provides a setting for you to determine how the system will respond when AC power is lost and then restored to the system. You can choose for the system to remain powered off (in which case you must hit the power switch to turn it back on) or for it to automatically return to a power- on state. See the Advanced BIOS Setup section to change this setting. The default setting is Last State.
1-5 PC Health Monitoring
This section describes the PC health monitoring features of the X8DTH-6/X8DTH­6F/X8DTH-i/X8DTH-iF. All have an onboard System Hardware Monitor chip that supports PC health monitoring. An onboard voltage monitor will scan these onboard voltages continuously: CPU1 Vcore, CPU2 Vcore, CPU1 Vtt, CPU2 Vtt, CPU1 DIMM, CPU2 DIMM, 1.1V, 1.5V, 1.8V, 3.3V, 12V, 5V, 3.3 Vsb, and VBAT. Once a voltage becomes unstable, a warning is given or an error message is sent to the screen. the user can adjust the voltage thresholds to defi ne the sensitivity of the voltage monitor.
Fan Status Monitor with Firmware Control
The PC health monitor can check the RPM status of the cooling fans. The onboard CPU and chassis fans are controlled by Thermal Management via BIOS (under Hardware Monitoring in the Advanced Setting).
Environmental Temperature Control
The thermal control sensor monitors the CPU temperature in real time and will turn on the thermal control fan whenever the CPU temperature exceeds a user-defi ned threshold. The overheat circuitry runs independently from the CPU. Once it detects that the CPU temperature is too high, it will automatically turn on the thermal fan control to prevent any overheat damage to the CPU. The onboard chassis thermal circuitry can monitor the overall system temperature and alert users when the chas­sis temperature is too high.
Warning! To avoid system overheating, be sure to provide adequate air ow to the system.
System Resource Alert
This feature is available when used with Supero D octor III in the Windows OS
1-10
Page 19
Chapter 1: Introduction
environment or used with Supero Doctor II in Linux. Supero Doctor is used to notif y the user of cer tain system events. For example, you can also confi gure Supero Doctor to provide you with warnings when the system temperature, CPU temperat ures, volt ages a nd fan spe eds go beyon d a pre- defi ned range.
1-6 ACPI Features
ACPI stands for Advanced Confi guration and Power Interface. The ACPI specifi ca- tion defi nes a fl exible and abstract hardware interface that provides a standard way to integrate power management features throughout a PC system, including its hardware, operating system and application software. This enables the system to automatically turn on and off peripherals such as CD-ROMs, network cards, hard disk drives and printers.
In addition to enabling operating system-directed power management, ACPI provides a generic system event mechanism for Plug and Play and an operating system-independent interface for confi guration control. ACPI leverages the Plug and Play BIOS data structures while providing a processor architecture-independent implementation that is compatible with both Windows 2000 and Windows 2003 Operating Systems.
Slow Blinking LED for Suspend-State Indicator
When the CPU goes into a suspend state, the chassis power LED will start blinking to indicate that the CPU is in suspend mode. When the user presses any key, the CPU will wake-up and the LED will automatically stop blinking and remain on.
Main Switch Override Mechanism
When an ATX power supply is used, the power button can function as a system suspend button to make the system enter a SoftOff state. The monitor will be suspended and the hard drive will spin down. Pressing the power button again will cause the whole system to wake-up. During the SoftOff state, the ATX power supply provides power to keep the required circuitry in the system "alive." In case the system malfunctions and you want to turn off the power, just press and hold the power button for 4 seconds. This option can be set in the Power section of the BIOS Setup routine.
1-7 Power Supply
As with all computer products, a stable power source is necessary for proper and reliable operation. It is even more important for processors that have high CPU clock rates.
1-11
Page 20
X8DTH-6/X8DTH-6F/X8DTH-i/X8DTH-iF User's Manual
The X8DTH-6/X8DTH-6F/X8DTH-i/X8DTH-iF can accommodate 24-pin ATX power supplies. Although most power supplies generally meet the specifi cations required by the CPU, some are inadequate. In addition, the two 12V 8-pin power connections are also required to ensure adequate power supply to the system. Also your power supply must supply 1.5A for the Ethernet ports.
Warning: To prevent damage to the power supply or motherboard, please use a power supply that contains a 24-pin and two 8-pin power connectors. Be sure to connect these connectors to the 24-pin (JPW1) and the two 8-pin (JPW2,JPW3) power connectors on the motherboard for adequate power supply to your system. Failure in doing so will void the manufacturer warranty on your power supply and motherboard.
It is strongly recommended that you use a high quality power supply that meets ATX power supply Specifi cation 2.02 or above. It must also be SSI compliant (For more information, please refer to the website at http://www.ssiforum.org/). Additionally, in areas where noisy power transmission is present, you may choose to install a line lter to shield the computer from noise. It is recommended that you also install a power surge protector to help avoid problems caused by power surges.
1-8 Super I/O
The Super I/O supports 360 K, 720 K, 1.2 M, 1.44 M or 2.88 M disk drives and data transfer rates of 250 Kb/s, 500 Kb/s or 1 Mb/s. It also provides two high-speed, 16550 compatible serial communication ports (UARTs). Each UART includes a 16­byte send/receive FIFO, a programmable baud rate generator, complete modem control capability and a processor interrupt system. Both UARTs provide legacy speed with baud rate of up to 115.2 Kbps as well as an advanced speed with baud rates of 250 K, 500 K, or 1 Mb/s, which support higher speed modems.
The Super I/O provides functions that comply with ACPI (Advanced Confi guration and Power Interface), which includes support of legacy and ACPI power manage­ment through an SMI or SCI function pin. It also features auto power management to reduce power consumption.
1-9 Overview of the Winbond WPCM450 Controller (For X8DTH-6F/iF Only)
The Winbond Hermon WPCM450 Controller is a Baseboard Management Con-
troller (BMC) that supports the 2D/VGA-compatible Graphics Core with the PCI interface, Virtual Media, and Keyboard/Video/Mouse Redirection (KVMR) modules. With blade-oriented Super I/O capability built-in, the Hermon Controller is ideal for legacy-reduced server platforms.
1-12
Page 21
Chapter 1: Introduction
The Winbond Hermon WPCM450 Controller interfaces with the host system via a PCI interface to communicate with the Graphics core. It supports USB 2.0 and 1.1 for remote keyboard/mouse/virtual media emulation. It also provides LPC interface to control Super IO functions. The Winbond WPCM450 BMC is connected to the network via an external Ethernet PHY module.
The Winbond WPCM450 BMC communicates with onboard components via six SMBus interfaces, fan control, and Platform Environment Control Interface (PECI).
1-13
Page 22
X8DTH-6/X8DTH-6F/X8DTH-i/X8DTH-iF User's Manual
Notes
1-14
Page 23
Chapter 2: Installation
Chapter 2
Installation
2-1 Static-Sensitive Devices
Electrostatic Discharge (ESD) can damage electronic com ponents. T o prevent dam­age to your system board, it is important to handle it very carefully. The following measures are generally suffi cient to protect your equipment from ESD.
Precautions
Use a grounded wrist strap designed to prevent static discharge.
Touch a grounded metal object before removing the board from the antistatic bag.
Handle the board by its edges only; do not touch its components, peripheral
chips, memory modules or gold contacts.
When handling chips or modules, avoid touching their pins.
Put the motherboard and peripherals back into their antistatic bags when not in use.
For grounding purposes, make sure your computer chassis provides excellent
conductivity between the power supply, the case, the mounting fasteners and the motherboard.
Use only the correct type of onboard CMOS battery as specifi ed by the
manufacturer. Do not install the onboard battery upside down to avoid possible explosion.
Unpacking
The motherboard is shipped in antist atic packag i n g t o avo id static da m a ge. When unpacking the board, make sure the person handling it is static protected.
2-1
Page 24
X8DTH-6/X8DTH-6F/X8DTH-i/X8DTH-iF User's Manual
2-2 Motherboard Installation
All motherboards have standard mounting holes to fi t different types of chassis. Make sure that the locations of all the mounting holes for both motherboard and chassis match. Although a chassis may have both plastic and metal mounting fasteners, metal ones are highly recommended because they ground the mother­board to the chassis. Make sure that the metal standoffs click in or are screwed in tightly. Then use a screwdriver to secure the motherboard onto the motherboard tray. Note: Some components are very close to the mounting holes. Please take precautionary measures to prevent damage to these components when installing the motherboard to the chassis.
Tools Needed
1. Phillips Screwdriver
2. Pan head #6 screws
Locations of Mounting Holes
Installation Instructions
Install the IO shield into the chassis. 1.
Locate the mounting holes on the moth-2. erboard. Refer to the layout above for mounting hole locations.
Locate the matching mounting holes on 3. the chassis. Align the mounting holes on the motherboard against the mounting holes on the chassis.
Install standoffs in the chassis as needed.4.
Install the motherboard into the chassis carefully to avoid damage to mother-5. board components.
Warning: To avoid damaging the motherboard and its components, please do not apply any force greater than 8 lb/sq.in (8 lbs. per square inch) when installing a screw into a mounting hole.
X8DTH
Rev. 1.01
Insert a Pan head #6 screw into a mounting hole on the motherboard and its 6. matching mounting hole on the chassis, using a Phillips screwdriver.
Repeat Step 4 to insert #6 screws to all mounting holes.7.
Make sure that the motherboard is securely placed on the chassis.8.
2-2
Page 25
2-3 Processor and Heatsink Installation
!
When handling the processor package, avoid placing direct pressure on the label area of the fan.
Notes:
Always connect the power cord last and always remove it before adding, re-1. moving or changing any hardware components. Make sure that you install the processor into the CPU socket before you install the CPU heatsink.
Make sure to install the motherboard into the chassis before you install the 2. CPU heatsink and heatsink fans.
When purchasing a motherboard without a 5500 Series processor pre-3. installed, make sure that the CPU socket plastic cap is in place, and none of the CPU socket pins are bent; otherwise, contact the retailer immediately.
Chapter 2: Installation
Refer to the M B Features S ecti on for mo re deta ils on CPU s uppor t.4.
Installing an LGA 1366 Processor
Press the socket clip to release 1. the load plate, which covers the CPU socket, from its locking position.
Gently lift the socket clip to 2. open the load plate.
Socket Clip
Plastic Cap
Load Plate
Hold the plastic cap at its north 3. and south center edges to re­move it from the CPU socket.
Hold the north & south edges of the plastic cap to remove it
2-3
Page 26
X8DTH-6/X8DTH-6F/X8DTH-i/X8DTH-iF User's Manual
After removing the plastic cap, 1. using your thumb and the index nger, hold the CPU at the
CPU CPU SocketLoad Plate
north and south center edges.
Align the CPU key, the semi-2. circle cutout, against the socket key, the notch below the gold color dot on the side of the socket.
Once both the CPU and the 3. socket are aligned, carefully lower the CPU straight down
Socket Keys
into the socket. (Do not rub the CPU against the surface of the socket or its pins to avoid dam­aging the CPU or the socket.)
With the CPU inside the socket, 4. inspect the four corners of the CPU to make sure that the CPU is properly installed.
Once the CPU is securely 5. seated on the socket, lower the CPU load plate to the socket.
Use your thumb to gently push 6. the socket clip down to the clip lock.
Warning: Please s ave the plastic cap. The mother­board must be shipped with the plastic cap prop­erly ins tal led to p rotec t the CPU socket pins. Ship­ment without the plastic cap properly installed will cause damage to the sock­et pins.
CPU Keys
2-4
Page 27
Installing a CPU Heatsink
Do not apply any thermal 1. grease to the heatsink or the CPU die because the required amount has already been ap­plied.
Chapter 2: Installation
Place the heatsink on top of the 2. CPU so that the four mounting holes are aligned with those on the retention mechanism.
3. Install two diagonal screws (ie the #1 and the #2 screws) and tighten them until just snug (-do not fully tighten the screws to avoid possible damage to the CPU.)
Screw#1
Screw#1
Install Screw#1
Screw#2
Screw#2
4. Finish the installation by fully tightening all four screws.
2-5
Page 28
X8DTH-6/X8DTH-6F/X8DTH-i/X8DTH-iF User's Manual
Removing the Heatsink
Warni ng: We do not recommend that the CPU or the heatsink be re­moved. However, if you do need to remove the heatsink, please follow the inst ructions be low to uninstall th e heatsink and prevent da mage to the CPU or ot her co mpone nts.
Unplug the power cord from the 1. power supply.
Disconnect the heatsink fan 2. wires from the CPU fan header.
Using a screwdriver, loosen and 3. remove the heatsink screws from the motherboard in the se­quence as show in the picture on the right.
Using a screwdriver to remove Screw#1
Hold the heatsink as shown 4. in the picture on the right and gently wriggle the heatsink to loosen it from the CPU. (Do not use excessive force when wrig­gling the heatsink.)
Once the heatsink is loosened, 5. remove it from the CPU socket.
To reinstall the CPU and the 6. heatsink, clean the surface of the CPU and the heatsink to get rid of the old thermal grease. Reapply the proper amount of thermal grease on the surface before reinstalling them on the motherboard.
Remove Screw#2
2-6
Page 29
Chapter 2: Installation
2-4 Memory Installation
Note: Check the S uper micr o website fo r rec ommen ded mem or y modul es.
CAUTION
Exercise extreme care when installing or removing DIMM
module s to prevent any po ssib le damag e. Also n ote that th e
memor y is i nterl eaved to imp rove per fo rman ce (See ste p 1).
DIMM Installation
Insert the desired number of DIMMs into the memory slots, starting with 1. DIMM #P1-DIMM1A. When populating DIMM modules always start with Chan­nel1 (#P1-DIMM1A and 1B) fi rst. For optimal memory performance, please use memory modules of the same type and the same speed on the mother­board. (See the Memory Installation Table Below.)
Insert each DIMM module vertically into its slot. Pay attention to the notch 2. along the bottom of the module to prevent inserting the DIMM module incor­rectly.
Gently press down on the DIMM module until it snaps into place in the slot. 3. Repeat for all modules.
Memory Support
The X8DTH-6/X8DTH-6F/X8DTH-i/X8DTH-iF supports up to 96 GB of Registered ECC or 24 GB of Unbuffered ECC/Non-ECC DDR3 1333/1066/800 MHz Memory in 12 DIMMs.
Memory Population for Optimal Performance
-For a motherboard with One CPU (CPU1) installed
Branch 0 Branch 1 Branch 2
3 DIMMs P1 DIMM1A P1 DIMM2A P1 DIMM3A 6 DIMMs P1 DIMM1A P1 DIMM1B P1 DIMM2A P1 DIMM2B P1 DIMM3A P1 DIMM3B
Memory Population for Optimal Performance
-For a motherboard with Two CPUs installed
Branch 0 Branch 1 Branch 3 Branch 0 Branch 1 Branch 3
6 DIMMs 1A 2A 3A 1A 2A 3A 12
DIMMs
1A 1B 2A 2B 3A 3B 1A 1B 2A 2B 3A 3B
CPU1 CPU2
2-7
Page 30
X8DTH-6/X8DTH-6F/X8DTH-i/X8DTH-iF User's Manual
Note: Memory speed support depends on the CPU used on the moth­erboard.
DIMM Module Population Confi guration
For memor y to wor k pro perl y, follow the tab les be low for me mor y inst allati on:
DIMM Population Table
DIMM Slots per Channel
2 1 FBD DDR3 ECC 1066,1333 SR, DR 2 1 FBD DDR3 ECC 1066, QR 2 2 FBD DDR3 ECC 1066,1333 SR, DR 2 2 FBD DDR3 ECC 1066 SR, DR, QR
DIMMs Populated per Channel
DIMM Type (FBD= Fully Buffered)
Speeds (in MHz) Ranks per DIMM
(any combination; SR=Single Rank, DR=Dual Rank, QR=Quad Rank)
Note 1: Due to OS limitations, some operating systems may not show
more than 4 GB of memory. Note 2: Due to memory allocation to system devices, the amount of
memory that r ema ins avai lab le fo r op erat io nal u se wi ll be r edu ce d wh en 4 GB of R A M is us ed. T he re duc tio n in me mor y ava ilab ili ty i s disp rop or­tiona l. (See the fo llowi ng Mem or y Availabi lity Table.)
Possible System Memory Allocation & Availability
System Device Size Physical Memory
Firmware Hub fl ash memory (System BIOS)
Local APIC 4 KB 3.99 GB Area Reserved for the chipset 2 MB 3.99 GB I/O APIC (4 Kbytes) 4 KB 3.99 GB PCI Enumeration Area 1 256 MB 3.76 GB PCI Express (256 MB) 256 MB 3.51 GB PCI Enumeration Area 2 (if needed)
-Aligned on 256-MB boundary­VGA Memory 16 MB 2.85 GB TSEG 1 MB 2.84 GB Memory available for the OS & other
applications
1 MB 3.99 GB
512 MB 3.01 GB
Remaining (-Available) (4 GB Total System Memory)
2.84 GB
2-8
Page 31
Installing and Removing DIMMs
Chapter 2: Installation
X8DTH
Rev. 1.01
Release Tab
Notch
Release
Tab
DIMM DDR3
Note: Notch
should align
with the
receptive point
on the slot
Notch
Release
Tab
To Install : Insert module vertically and press down until it s naps i nto pla ce. Pay at tent ion to t he ali gn ­ment not ch at th e bot tom.
3
Release Tab
To Remove:
Use your thumbs to gently push the release tabs near both ends of the module. This should release it from the slot.
2-9
Page 32
X8DTH-6/X8DTH-6F/X8DTH-i/X8DTH-iF User's Manual
123
4
5
6
789
2-5 Control Panel Connectors/IO Ports
The I/O p ort s are col or cod ed in co nforma nce wit h the PC 9 9 speci fi cation. See the pic ture be low for t he co lors a nd loc atio ns of the var ious I /O por t s.
1. Back Panel Connectors/IO Ports
X8DTH
Rev. 1.01
Back Panel I/O Port Locations and Defi nitions
Back Panel Connectors
Keyboard (Purple)1. PS/2 Mouse (Green)2. USB 03. USB 14. IPMI_Dedicated LAN (X8DTH-iF/6F only)5. COM Port 16. VGA (Blue) 7. LAN 18. LAN 29.
2-10
Page 33
Chapter 2: Installation
1
2
ATX PS/2 Keyboard and PS/2 Mouse Ports
The ATX PS/2 keyboard and PS/2 mouse are located next to the Back Panel USB ports on the motherboard. See the table at right for pin defi ni- tions.
PS/2 Keyboard/Mouse Pin
Defi nitions
PS2 Keyboard PS2 Mouse Pin# Defi nition Pin# Defi nition 1 KB Data 1 Mouse Data 2 No Connection 2 No Connection 3 Ground 3 Ground
4 Mouse/KB VCC
(+5V) 5 KB Clock 5 Mouse Clock 6 No Connection 6 No Connection VCC: with 1.5A PTC (current limit)
4 Mouse/KB VCC
(+5V)
X8DTH
Rev. 1.01
1. Keyboard (Purple)
2. Mouse (Green)
2-11
Page 34
X8DTH-6/X8DTH-6F/X8DTH-i/X8DTH-iF User's Manual
1
2
Serial Ports
Two COM connections (COM1 & COM_ DBG) are located on the motherboard. COM1 is located on the Backplane IO panel to provide serial connection sup­port for the motherboard. See the table on the right for pin defi nitions.
Video Connector
A Video (VGA) connector is located next to COM Port1 on the IO back­plane. This connector is used to pro­vide video display. Refer to the board layout below for the location.
Serial Ports
Pin Defi nitions
Pin # Defi nition Pin # Defi nition 1 DCD 6 DSR 2 RXD 7 RTS 3 TXD 8 CTS 4 DTR 9 RI 5 Ground 10 N/A
X8DTH
Rev. 1.01
1. COM 1
2. VGA
2-12
Page 35
Chapter 2: Installation
1
2
345
Universal Serial Bus (USB)
Two Universal Serial Bus ports (USB 0/1) are located on the I/O back panel. Additionally, five USB connections (USB 3, 4/5, 6/7) are on the mother­board to provide front chassis access. (Cables are not included). See the tables on the right for pin defi nitions.
Back Panel USB
(USB 0/1)
Pin# Defi nitions 1 +5V 2 PO­3 PO+ 4 Ground 5 N/A
Pin Defi nitions (USB 4/5, 6/7)
USB4/6 Pin # Defi nition
1 +5V 1 +5V 2 PO- 2 PO­3 PO+ 3 PO+ 4 Ground 4 Ground 5 Key 5 No connection
Front Panel USB
(USB 3)
Pin# Defi nition 1 Vcc 2 Data­3 Data+ 4 Ground 5NA
Front Panel USB
USB 5/7 Pin # Defi nition
X8DTH
Rev. 1.01
1. Backpanel USB 0
2. Backpanel USB 1
3. Front panel USB 3
4. Front panel USB 4/5
5. Front panel USB 6/7
2-13
Page 36
X8DTH-6/X8DTH-6F/X8DTH-i/X8DTH-iF User's Manual
1
2
3
Ethernet Ports
Two Ethernet ports (LAN 1/LAN2) are located at on the IO backplane. In addition, a dedicated LAN is also lo­cated on the X8DTH-iF/6F to provide KVM support for IPMI 2.0. All these ports accept RJ45 type cables. (Note: Please refer to the LED Indicator Sec­tion for LAN LED information.)
LAN Ports
Pin Defi nition
Pin# Defi nition 1 P2V5SB 10 SGND 2 TD0+ 11 Act LED 3 TD0- 12 P3V3SB 4 TD1+ 13 Link 100 LED
(Yellow, +3V3SB)
5 TD1- 14 Link 1000 LED
(Yellow, +3V3SB) 6 TD2+ 15 Ground 7 TD2- 16 Ground 8 TD3+ 17 Ground 9 TD3- 88 Ground
(NC: No Connection)
X8DTH
Rev. 1.01
1. LAN1
2. LAN2
3. IPMI LAN (X8DTH-iF/6F only)
2-14
Page 37
Chapter 2: Installation
2. Front Control Panel
JF1 contains header pins for various buttons and indicators that are normally located on a control panel at the front side of the chassis. These connectors are designed specifi cally for use with Supermicro server chassis. See the fi gure below for the descriptions of the various control panel buttons and LED indicators. Refer to the following section for descriptions and pin defi nitions.
JF1 Header Pins
X8DTH
Rev. 1.01
Ground
Power LED
HDD LED
NIC1 LED
NIC2 LED
1920
NMI
X
X
Vcc
Vcc
Vcc
Vcc
OH/Fan Fail LED
PWR Fail LED
Ground
Ground
2-15
Vcc
Vcc
Reset
PWR
2
1
Reset Button
Power Button
Page 38
X8DTH-6/X8DTH-6F/X8DTH-i/X8DTH-iF User's Manual
3. Front Control Panel Pin Defi nitions
NMI Button
The non-maskable interrupt button header is located on pins 19 and 20 of JF1. Refer to the table on the right for pin defi nitions.
Power LED
The Power LED connection is located on pins 15 and 16 of JF1. Refer to the table o n the ri ght for p in defi nitions.
NMI Button
Pin Defi nitions (JF1)
Pin# Defi nition 19 Control 20 Ground
Power LED
Pin Defi nitions (JF1)
Pin# Defi nition 15 +5V 16 Ground
X8DTH
Rev. 1.01
2-16
A. NMI B. PWR LED
Ground
X
Power LED
B
HDD LED
NIC1 LED
NIC2 LED
OH/Fan Fail LED
PWR Fail LED
Ground
Ground
1920
NMI
A
X
Vcc
Vcc
Vcc
Vcc
Vcc
Vcc
Reset
Reset Button
Power Button
PWR
2
1
Page 39
Chapter 2: Installation
HDD LED
The HDD LED connection is located on pins 13 and 14 of JF1. Attach a cable here to indicate HDD activ­ity. See the table on the right for pin defi nitions.
NIC1/NIC2 LED Indicators
The NIC (Network Interface Control­ler) LED connection for GLAN port 1 is located on pins 11 and 12 of JF1, and the LED connection for GLAN Port 2 is on Pins 9 and 10. Attach the NIC LED cables to display network activity . Refer to the table on the right for pin defi nitions.
HDD LED
Pin Defi nitions (JF1)
Pin# Defi nition 13 +5V 14 HD Active
GLAN1/2 LED
Pin Defi nitions (JF1)
Pin# Defi nition 9/11 Vcc 10/12 Ground
X8DTH
Rev. 1.01
A
B
C
OH/Fan Fail LED
2-17
Ground
X
Power LED
HDD LED
NIC1 LED
NIC2 LED
PWR Fail LED
Ground
Ground
A. HDD LED B. NIC1 LED C. NIC2 LED
1920
NMI
Vcc
Vcc
Vcc
Vcc
Vcc
Vcc
Reset
PWR
2
1
X
Reset Button
Power Button
Page 40
X8DTH-6/X8DTH-6F/X8DTH-i/X8DTH-iF User's Manual
Overheat (OH)/Fan Fail LED
Connect an LED cable to the OH/ Fan Fail connections on pins 7 and 8 of JF1 to provide advanced warn­ings for chassis overheat/fan failure. Refer to the table on the right for pin defi nitions.
Power Fail LED
The Power Fail LED connection is locate d on pins 5 and 6 of JF1. Re­fer to the table on the right for pin defi nitions.
OH/Fan Fail LED
Pin Defi nitions (JF1)
Pin# Defi nition 7 Vcc 8 OH/Fan Fail LED
OH/Fan Fail Indicator
Status
State Defi nition Off Normal On Overheat Flash-
ing
Pin Defi nitions (JF1)
Pin# Defi nition 5 Vcc 6 Ground
Fan Fail
PWR Fail LED
X8DTH
Rev. 1.01
A
OH/Fan Fail LED
B
PWR Fail LED
2-18
Ground
Power LED
HDD LED
NIC1 LED
NIC2 LED
A. OH/Fan Fail LED B. PWR Supply Fail
1920
X
Ground
Ground
2
Reset
1
NMI
X
Vcc
Vcc
Vcc
Vcc
Vcc
Vcc
PWR
Reset Button
Power Button
Page 41
Chapter 2: Installation
Reset Button
The Reset Button connection is located on pins 3 and 4 of JF1. Attach it to a hardware reset switch on the computer case. Refer to the table on the right for pin defi nitions.
Power Button
The Power Button connection is located on pins 1 and 2 of JF1. Momentarily con­tacting both pins will power on/off the sys­tem. This button can also be confi gured to function as a suspend button (with a setting in the BIOS - see Chapter 4). To turn off the power when set to suspend mode, press the button for at least 4 seconds. Refer to the table on the right for pin defi nitions.
Reset Button
Pin Defi nitions (JF1)
Pin# Defi nition 3 Reset 4 Ground
Power Button
Pin Defi nitions (JF1)
Pin# Defi nition
1 Signal 2 +3V Standby
X8DTH
Rev. 1.01
Power LED
HDD LED
NIC1 LED
NIC2 LED
OH/Fan Fail LED
PWR Fail LED
2-19
Ground
X
Ground
Ground
A. Reset Button B. PWR Button
1920
NMI
X
Vcc
Vcc
Vcc
Vcc
Vcc
Vcc
Reset
PWR
2
1
Reset Button
Power Button
A
B
Page 42
X8DTH-6/X8DTH-6F/X8DTH-i/X8DTH-iF User's Manual
2-6 Connecting Cables
Power Connectors
A 24-pin main power supply connector(JPW1) and two 8-pin CPU PWR connectors (JPW2/ JPW3) on the motherboard. These power connectors meet the SSI EPS 12V specifi - cation. In addition to the 24-pin ATX power connector, the 12V 8-pin CPU PWR connec­tors at JPW2/JPW3 must also be connected to your power supply. See the table on the right for pin defi nitions.
Warning: To prevent damage to the power supply or motherboard, please use a power supply that contains a 24-pin and two 8-pin power connectors. Be sure to connect these connectors to the 24-pin (JPW1) and the two 8-pin (JPW2,JPW3) power connectors on the motherboard. Failure in do­ing so will void the manufacturer warranty on your power supply and motherboard.
FAN5
KB/MS
FAN6
USB0/1
IPMI_LAN
COM1
P2-DIMM3A
P2-DIMM3B
P2-DIMM2A
P2-DIMM2B
P2-DIMM1A
P2-DIMM1B
J7
ATX Power 24-pin Connector
Pin Defi nitions
Pin# Defi nition Pin # Defi nition 13 +3.3V 1 +3.3V 14 -12V 2 +3.3V 15 COM 3 COM 16 PS_ON 4 +5V 17 COM 5 COM 18 COM 6 +5V 19 COM 7 COM 20 Res (NC) 8 PWR_OK 21 +5V 9 5VSB 22 +5V 10 +12V 23 +5V 11 +12V 24 COM 12 +3.3V
12V 8-pin PWR Connector
Pin Defi nitions
Pins Defi nition 1 through 4 Ground 5 through 8 +12V
(Required)
A. 24-pin ATX PWR (Req'd) B/C.8-pin Processor PWR (Req'd)
A
JPI2C
JPW1
CPU1
C
B
JPW2
JPW3
FAN1
FAN7
VGA
PHY
LAN1
LAN2
FAN8
JPL1
LAN CTRL
BMC
DP5
Slot7 PCI-E 2.0 X8
Slot6 PCI-E 2.0 X8
Slot5 PCI-E 2.0 X8
JI2C2
JI2C1
Slot4 PCI-E 2.0 X8
Slot3 PCI-E 2.0 X8
Slot2 PCI-E 2.0 X8
Slot1 PCI-E 2.0 X8
JPG1
JPB
CPU2
USB6/7
USB4/5
(South Bridge)
USB3
(IOH36D-2)
Intel
ICH10R
SATA-SGPIO1 SATA-SGPIO0
JF1
PWR_LED
DP4
P1-DIMM1B
P1-DIMM1A
P1-DIMM2B
P1-DIMM2A
P1-DIMM3B
P1-DIMM3A
X8DTH
(IOH36D-1)
LED5
SAS Activity
I-SATA1
Intel
5520
Rev. 1.01
DP6 DP7
I-SATA0
J*
LSI SAS2008
JPS1
RAID Key
Intel
5520
JBT1
SPI BIOS
I-SATA5
I-SATA3
I-SATA4
I-SATA2
JWD
FAN2
SMBus1
JOH1
JD1
FAN3
Battery
Buzzer
SAS
FLASH
SAS0~3
SAS4~7
FAN4
JL1
2-20
Page 43
Chapter 2: Installation
D
E
F
G
Fan Headers
This motherboard has eight CPU/system fan headers (Fan 1 to Fan8) on the moth­erboard. All these 4-pin fans headers are backward compatible with the traditional 3-pin fans. However, fan speed control is available for 4-pin fans only. The fan speeds are controlled by Thermal Man­agement via Hardware Monitoring in the Advanced Setting in the BIOS. (The Default setting is Disabled.) See the table on the right for pin defi nitions.
Chassis Intrusion
A Chassis Intrusion header is located at JL1 on the motherboard. Attach an appropriate cable from the chassis to inform you of a chassis intrusion when the chassis is opened.
Fan Header
Pin Defi nitions
Pin# Defi nition 1 Ground 2 +12V 3 Tachometer 4 PWR Modulation
Chassis Intrusion
Pin Defi nitions (JL1)
Pin# Defi nition 1 Intrusion Input 2 Ground
A. Fan 1
FAN5
KB/MS
FAN6
USB0/1
IPMI_LAN
COM1
VGA
PHY
LAN1
LAN2
FAN8
JPL1
LAN CTRL
BMC
DP5
P2-DIMM3A
P2-DIMM3B
P2-DIMM2A
P2-DIMM2B
P2-DIMM1A
P2-DIMM1B
CPU2
H
Slot7 PCI-E 2.0 X8
Slot6 PCI-E 2.0 X8
Slot5 PCI-E 2.0 X8
JI2C2
JI2C1
Slot4 PCI-E 2.0 X8
Slot3 PCI-E 2.0 X8
Slot2 PCI-E 2.0 X8
Slot1 PCI-E 2.0 X8
JPG1
JPB
(South Bridge)
USB3
USB4/5
USB6/7
(IOH36D-2)
Intel
ICH10R
SATA-SGPIO1 SATA-SGPIO0
J7
JPI2C
JPW2
JPW1
JPW3
FAN1
A
B. Fan 2 C. Fan 3 D. Fan 4
CPU1
P1-DIMM1B
P1-DIMM1A
P1-DIMM2B
P1-DIMM2A
P1-DIMM3B
P1-DIMM3A
X8DTH
I-SATA3
I-SATA2
(IOH36D-1)
LED5
SAS Activity
I-SATA1
Intel
5520
DP6 DP7
Rev. 1.01
J*
JPS1
I-SATA0
RAID Key
LSI SAS2008
Intel
5520
JBT1
SPI BIOS
I-SATA5
I-SATA4
FAN7
JF1
PWR_LED
DP4
FAN2
JOH1
FAN3
Battery
Buzzer
SAS
FLASH
SAS0~3
SAS4~7
FAN4
JL1
E. Fan 5 F. Fan 6 G. Fan 7
JWD
H. Fan 8
B
SMBus1
I. Chassis Intrusion
JD1
C
I
2-21
Page 44
X8DTH-6/X8DTH-6F/X8DTH-i/X8DTH-iF User's Manual
Power LED/Speaker
On the JD1 header, pins 1-3 are used for power LED indication, and pins 4-7 are for the speaker. See the tables on the right for pin defi nitions. Please note that the speaker connector pins (4-7) are for use with an external speaker. If you wish to use the on­board speaker, you should close pins 6-7 with a jumper.
PWR LED Connector
Pin Defi nitions
Pin Setting Defi nition Pin 1 Anode (+) Pin2 Cathode (-) Pin3 NA
Speaker Connector
Pin Defi nitions
Pin Setting Defi nition Pins 4-7 External Speaker Pins 6-7 Internal Speaker
A. PWR LED/Speaker
FAN5
KB/MS
FAN6
USB0/1
IPMI_LAN
COM1
VGA
PHY
LAN1
LAN2
FAN8
JPL1
LAN CTRL
BMC
DP5
JPG1
JI2C2
Slot7 PCI-E 2.0 X8
Slot6 PCI-E 2.0 X8
Slot5 PCI-E 2.0 X8
JI2C1
Slot4 PCI-E 2.0 X8
Slot3 PCI-E 2.0 X8
Slot2 PCI-E 2.0 X8
Slot1 PCI-E 2.0 X8
JPB
P2-DIMM3A
P2-DIMM3B
P2-DIMM2A
P2-DIMM2B
P2-DIMM1A
P2-DIMM1B
CPU2
(South Bridge)
USB3
USB4/5
USB6/7
(IOH36D-2)
Intel
ICH10R
SATA-SGPIO1 SATA-SGPIO0
J7
JPI2C
CPU1
P1-DIMM1B
P1-DIMM1A
P1-DIMM2B
P1-DIMM2A
P1-DIMM3B
P1-DIMM3A
Intel
5520
Intel
5520
(IOH36D-1)
JBT1
I-SATA5
I-SATA4
SPI BIOS
I-SATA2
I-SATA3
LED5
SAS Activity
I-SATA1
JPW1
X8DTH
Rev. 1.01
J*
DP6 DP7
JPS1
I-SATA0
RAID Key
LSI SAS2008
JPW2
JPW3
FAN1
FAN7
JF1
PWR_LED
DP4
JWD
FAN2
SMBus1
JOH1
A
JD1
FAN3
Battery
Buzzer
SAS
FLASH
SAS0~3
SAS4~7
FAN4
JL1
2-22
Page 45
Chapter 2: Installation
Overheat LED/Fan Fail (JOH1)
The JOH1 header is used to connect an LED indi c ato r to p rov id e war n in gs of chass is overhe ating or fa n failure. This LED will blink when a fan failure occu rs . Refer t o th e ta bl e on r i ght f or pin defi nitions.
SATA-SGPIO 0/1 Headers
Two SATA-SGPIO (General Pur­pose Input/Output) headers (SATA­SGPIO-0/SATA-SGPIO-1) are located the motherboard. These headers support serial link interfaces for the onboard SATA connectors. See the table on the right for pin defi nitions. Refer to the board layout below for the location.
Overheat LED
Pin Defi nitions
Pin# Defi nition 1 5vDC 2 OH Active
OH/Fan Fail LED
Pin Defi nitions
State Message Solid Overheat Blinking Fan Fail
SATA-SGPIO
Pin Defi nitions
Pin# Defi nition Pin Defi nition 1NC 2 NC 3 Ground 4 Data
5 Load 6 Ground 7NC 8 NC
Note: NC= No Connections
A. OH/Fan Fail LED
FAN5
KB/MS
FAN6
USB0/1
IPMI_LAN
COM1
VGA
PHY
LAN1
LAN2
FAN8
JPL1
LAN CTRL
BMC
DP5
P2-DIMM3A
P2-DIMM3B
P2-DIMM2A
P2-DIMM2B
P2-DIMM1A
P2-DIMM1B
CPU2
Slot7 PCI-E 2.0 X8
Slot6 PCI-E 2.0 X8
Slot5 PCI-E 2.0 X8
JI2C2
JI2C1
Slot4 PCI-E 2.0 X8
Slot3 PCI-E 2.0 X8
Slot2 PCI-E 2.0 X8
Slot1 PCI-E 2.0 X8
JPG1
JPB
(South Bridge)
USB3
USB4/5
USB6/7
(IOH36D-2)
Intel
ICH10R
SATA-SGPIO1 SATA-SGPIO0
J7
JPI2C
CPU1
P1-DIMM1B
P1-DIMM1A
P1-DIMM2B
P1-DIMM2A
P1-DIMM3B
P1-DIMM3A
Intel
5520
Intel
5520
(IOH36D-1)
JBT1
I-SATA5
C
I-SATA4
SPI BIOS
I-SATA2
I-SATA3
LED5
SAS Activity
I-SATA1
JPW1
X8DTH
Rev. 1.01
DP6 DP7
JPS1
I-SATA0
JPW2
JPW3
FAN1
FAN7
PWR_LED
DP4
Battery
Buzzer
SAS
FLASH
J*
LSI SAS2008
RAID Key
SAS0~3
SAS4~7
FAN4
B
B. SATA-SGPIO 0 C. SATA-SGPIO 1
JF1
JWD
FAN2
SMBus1
A
JOH1
JD1
FAN3
JL1
2-23
Page 46
X8DTH-6/X8DTH-6F/X8DTH-i/X8DTH-iF User's Manual
System Management Bus
A System Management Bus header is located at SUBUS1 on the mother­board. Connect an appropriate cable here to use the SMB connection on your system.
Power SMB (I2C) Connector
Power System Management Bus (I
2
C) Connector(JPI2C) monitors power supply, fan status and system tem­perature. See the table on the right for pin defi nitions.
SMB Header
Pin Defi nitions
Pin# Defi nition 1 Data 2 Ground 3 Clock 4 No Connection
PWR SMB
Pin Defi nitions
Pin# Defi nition 1 Clock 2 Data
3 PWR Fail 4 Ground 5 +3.3V
FAN5
KB/MS
FAN6
USB0/1
IPMI_LAN
COM1
VGA
PHY
LAN1
LAN2
FAN8
JPL1
LAN CTRL
BMC
DP5
P2-DIMM3A
P2-DIMM3B
P2-DIMM2A
P2-DIMM2B
P2-DIMM1A
P2-DIMM1B
CPU2
Slot7 PCI-E 2.0 X8
Slot6 PCI-E 2.0 X8
Slot5 PCI-E 2.0 X8
JI2C2
JI2C1
Slot4 PCI-E 2.0 X8
Slot3 PCI-E 2.0 X8
Slot2 PCI-E 2.0 X8
Slot1 PCI-E 2.0 X8
JPG1
JPB
(South Bridge)
USB3
USB4/5
USB6/7
(IOH36D-2)
Intel
ICH10R
SATA-SGPIO1 SATA-SGPIO0
J7
B
JPI2C
CPU1
P1-DIMM1B
P1-DIMM1A
P1-DIMM2B
P1-DIMM2A
P1-DIMM3B
P1-DIMM3A
Intel
5520
Intel
5520
(IOH36D-1)
JBT1
I-SATA5
I-SATA4
SPI BIOS
I-SATA2
I-SATA3
SAS Activity
I-SATA1
LED5
JPW1
X8DTH
Rev. 1.01
DP6
DP7
JPS1
I-SATA0
JPW2
JPW3
FAN1
FAN7
JF1
PWR_LED
DP4
JWD
FAN2
SMBus1
JOH1
JD1
FAN3
Battery
Buzzer
SAS FLASH
J*
LSI SAS2008
RAID Key
SAS0~3
SAS4~7
FAN4
JL1
A. SMB
JPI2C
B.
A
2-24
Page 47
2-7 Jumper Settings
Connector
Pins
Jumper
Cap
Setting
Chapter 2: Installation
Explanation of Jumpers
To modify the operation of the mother­board, jumpers can be used to choose between optional settings. Jumpers cre­ate shorts between two pins to change the function of the connector. Pin 1 is identifi ed with a square solder pad on the printed circuit board. See the motherboard layout pages for jumper locations.
Note: On two pin jumpers, "Closed" means the jumper is on and "Open" means the jumper i s of f the pin s.
GLAN Enable/Disable
Use JPL1 to enable or disable GLAN Port1/GLAN Port2 on the mother­board. See the table on the right for jumper s ettings. The d efault settin g is
Enabled.
3 2 1
3 2 1
Pin 1-2 short
GLAN Enable
Jumper Settings
Pin# Defi nition 1-2 Enabled (default) 2-3 Disabled
A. GLAN Port 1/2 Enable
FAN5
KB/MS
FAN6
USB0/1
IPMI_LAN
COM1
VGA
PHY
LAN1
LAN2
FAN8
JPL1
A
LAN CTRL
BMC
DP5
P2-DIMM3A
P2-DIMM3B
P2-DIMM2A
P2-DIMM2B
P2-DIMM1A
P2-DIMM1B
CPU2
Slot7 PCI-E 2.0 X8
Slot6 PCI-E 2.0 X8
Slot5 PCI-E 2.0 X8
JI2C2
JI2C1
Slot4 PCI-E 2.0 X8
Slot3 PCI-E 2.0 X8
Slot2 PCI-E 2.0 X8
Slot1 PCI-E 2.0 X8
JPG1
JPB
(South Bridge)
USB3
USB4/5
USB6/7
(IOH36D-2)
Intel
ICH10R
SATA-SGPIO1 SATA-SGPIO0
J7
JPI2C
CPU1
P1-DIMM1B
P1-DIMM1A
P1-DIMM2B
P1-DIMM2A
P1-DIMM3B
P1-DIMM3A
Intel
5520
Intel
5520
(IOH36D-1)
JBT1
I-SATA5
I-SATA4
SPI BIOS
I-SATA3
I-SATA2
LED5
SAS Activity
I-SATA1
JPW1
X8DTH
Rev. 1.01
J*
DP6 DP7
JPS1
I-SATA0
RAID Key
LSI SAS2008
JPW2
JPW3
FAN1
FAN7
JF1
PWR_LED
DP4
JWD
FAN2
SMBus1
JOH1
JD1
FAN3
Battery
Buzzer
SAS
FLASH
SAS0~3
SAS4~7
FAN4
JL1
2-25
Page 48
X8DTH-6/X8DTH-6F/X8DTH-i/X8DTH-iF User's Manual
CMOS Clear
JBT1 is used to clear CMOS. Instead of pins, this "jumper" consists of contact pads to prevent t he accident al clearin g of CMOS. To clear CMOS , use a metal objec t such as a sma ll screwdr iver to touc h both pad s at the same t ime to shor t the co nnec ti on. A lways rem ove the AC p ower c ord f rom t he syste m befo re cl ear­ing CMOS.
Note: For an ATX power supply, you must completely shut down the sys­tem, remove the AC power cord and then short JBT1 to clear CMOS.
Watch Dog Enable/Disable
Watch Dog (JWD) is a syste m monitor th at can reb oot t he sys tem w hen a s of tware ap­plicat ion han gs. Clo se Pins 1-2 to res et the system if an app lication ha ngs. Close Pins 2-3 to generate a non-maskable interrupt signal for the application that hangs. See the table on the right for jumper settings. Watch Dog must also be enabled in the BIOS.
FAN5
KB/MS
FAN6
USB0/1
IPMI_LAN
COM1
VGA
PHY
LAN1
LAN2
FAN8
JPL1
LAN CTRL
BMC
DP5
P2-DIMM3A
P2-DIMM3B
P2-DIMM2A
P2-DIMM2B
P2-DIMM1A
P2-DIMM1B
CPU2
Slot7 PCI-E 2.0 X8
Slot6 PCI-E 2.0 X8
Slot5 PCI-E 2.0 X8
JI2C2
JI2C1
Slot4 PCI-E 2.0 X8
Slot3 PCI-E 2.0 X8
Slot2 PCI-E 2.0 X8
Slot1 PCI-E 2.0 X8
JPG1
JPB
(South Bridge)
USB3
USB4/5
USB6/7
(IOH36D-2)
Intel
ICH10R
SATA-SGPIO1 SATA-SGPIO0
J7
JPI2C
P1-DIMM1A
P1-DIMM2B
P1-DIMM2A
P1-DIMM3B
P1-DIMM3A
Intel
5520
A
JBT1
SAS Activity
SPI BIOS
I-SATA5
I-SATA3
I-SATA4
I-SATA2
P1-DIMM1B
(IOH36D-1)
LED5
I-SATA1
JPW1
CPU1
Intel
5520
DP6
DP7
X8DTH
Rev. 1.01
J*
JPS1
I-SATA0
RAID Key
LSI SAS2008
Watch Dog
Jumper Settings (JWD)
Jumper Setting Defi nition Pins 1-2 Reset
(default) Pins 2-3 NMI Open Disabled
A. Clear CMOS
JPW2
JPW3
FAN1
FAN7
JF1
PWR_LED
DP4
JWD
FAN2
SMBus1
JOH1
FAN3
Battery
Buzzer
SAS FLASH
SAS0~3
SAS4~7
FAN4
JL1
B. Watch Dog Enable
B
JD1
2-26
Page 49
Chapter 2: Installation
I2C Bus to PCI-Exp. Slots
Use Jumpers JI the System Management Bus (I
2
C1 and JI2C2 to connect
2
C) to PCI-Express slots in order to improve PCI slot performance. These two jump­ers are to be set at the same time. The default setting is Closed to enable the connections. See the table on the right for jumper settings.
VGA Enable
Jumper JPG1 allows you to enable video connections on the motherboard. See the table on the right for jumper settings.
I2C for PCI-E slots
Jumper Settings
Jumper Setting Defi nition Closed Enabled (Default) Open Disabled
VGA Enable
Jumper Settings
Jumper Setting Defi nition 1~2 Enabled (Default) 2~3 Disabled
2
A. JI
C1
FAN5
KB/MS
FAN6
USB0/1
IPMI_LAN
COM1
VGA
PHY
LAN1
LAN2
FAN8
JPL1
LAN CTRL
BMC
DP5
P2-DIMM3A
P2-DIMM3B
P2-DIMM2A
P2-DIMM2B
P2-DIMM1A
P2-DIMM1B
CPU2
Slot7 PCI-E 2.0 X8
Slot6 PCI-E 2.0 X8
Slot5 PCI-E 2.0 X8
A
B
JI2C2
JI2C1
Slot4 PCI-E 2.0 X8
Slot3 PCI-E 2.0 X8
Slot2 PCI-E 2.0 X8
Slot1 PCI-E 2.0 X8
C
JPG1
JPB
(South Bridge)
USB3
USB4/5
USB6/7
(IOH36D-2)
Intel
ICH10R
SATA-SGPIO1 SATA-SGPIO0
J7
JPI2C
CPU1
P1-DIMM1B
P1-DIMM1A
P1-DIMM2B
P1-DIMM2A
P1-DIMM3B
P1-DIMM3A
Intel
5520
Intel
5520
(IOH36D-1)
JBT1
I-SATA5
I-SATA4
SPI BIOS
I-SATA3
I-SATA2
LED5
SAS Activity
I-SATA1
JPW1
X8DTH
Rev. 1.01
J*
DP6 DP7
JPS1
I-SATA0
RAID Key
LSI SAS2008
JPW2
JPW3
FAN1
FAN7
JF1
PWR_LED
DP4
JWD
FAN2
SMBus1
JOH1
JD1
FAN3
Battery
Buzzer
SAS
FLASH
SAS0~3
SAS4~7
FAN4
JL1
2
B. JI
C2
C. VGA Enable
2-27
Page 50
X8DTH-6/X8DTH-6F/X8DTH-i/X8DTH-iF User's Manual
SAS Enable (X8DTH-6/6F Only)
JPS1 allows you to enable or disable SAS Connectors. The default position is on pins 1 an d 2 to e na bl e SA S. S e e th e table o n the r ight fo r jumper s ett ings.
SAS Enable/Disable
Jumper Settings
Jumper Settings Defi nition Pins 1-2 Enabled (Default) Pins 2-3 Disabled
FAN5
KB/MS
FAN6
USB0/1
IPMI_LAN
COM1
VGA
PHY
LAN1
LAN2
FAN8
JPL1
LAN CTRL
BMC
DP5
P2-DIMM3A
P2-DIMM3B
P2-DIMM2A
P2-DIMM2B
P2-DIMM1A
P2-DIMM1B
CPU2
Slot7 PCI-E 2.0 X8
Slot6 PCI-E 2.0 X8
Slot5 PCI-E 2.0 X8
JI2C2
JI2C1
Slot4 PCI-E 2.0 X8
Slot3 PCI-E 2.0 X8
Slot2 PCI-E 2.0 X8
Slot1 PCI-E 2.0 X8
JPG1
JPB
(South Bridge)
USB3
USB4/5
USB6/7
(IOH36D-2)
Intel
ICH10R
SATA-SGPIO1 SATA-SGPIO0
J7
JPI2C
CPU1
P1-DIMM1B
P1-DIMM1A
P1-DIMM2B
P1-DIMM2A
P1-DIMM3B
P1-DIMM3A
Intel
5520
Intel
5520
(IOH36D-1)
JBT1
I-SATA5
I-SATA4
SPI BIOS
I-SATA2
I-SATA3
SAS Activity
I-SATA1
LED5
A
JPW1
X8DTH
Rev. 1.01
DP6
DP7
JPS1
I-SATA0
JPW2
JPW3
PWR_LED
Battery
SAS FLASH
J*
LSI SAS2008
RAID Key
SAS0~3
SAS4~7
FAN4
A. SAS Enable
FAN1
FAN7
JF1
DP4
JWD
FAN2
SMBus1
JOH1
JD1
FAN3
Buzzer
JL1
2-28
Page 51
Chapter 2: Installation
2-8 Onboard LED Indicators
GLAN LEDs
Two LAN ports (LAN 1/LAN 2) are located on the IO Backplane of the motherboard. Each Ethernet LAN port has two LEDs. The yellow LED indicates activity, while the oth­er Link LED may b e green, a mber or o ff to indic ate th e sp ee d of th e c on ne ct io ns . Se e the tab les at ri ght for mo re infor matio n.
IPMI Dedicated LAN LEDs (X8DTH­iF/6F)
In addition to LAN 1/LAN 2, an IPMI Dedi­cated LAN is also located on the IO Back­plane of the X8DTH-iF/6F. The am ber LED on the right indicates activity, while the green LED o n the left in dicates the s peed of the connection. See the tables at right for more i nform ation.
LAN1/LAN2
Activity LED
Rear View (when facing the
rear side of the chassis)
LAN 1/LAN 2 Activity LED (Right)
Color Status Defi nition Yellow Flashing Active
LAN 1/LAN 2 Link LED (Left)
LED Color Defi nition Off No Connection or 10 Mbps Green 100 Mbps Amber 1 Gbps
Link LED
IPMI LAN Link LED (Left) &
Color Status Defi nition Link (Left) Green: Solid 100 Mbps
Activity (Right)
LED State
LED State
IPMI LAN (X8DTH-iF/6F only)
Activity LED (Right)
Off Amber:
No Connection
Active
Blinking
Link LED
Activity LED
A. LAN1/2 LEDs
FAN5
KB/MS
FAN6
B
USB0/1
IPMI_LAN
COM1
VGA
PHY
LAN1
LAN2
FAN8
JPL1
LAN CTRL
BMC
DP5
P2-DIMM3A
P2-DIMM3B
P2-DIMM2A
P2-DIMM2B
P2-DIMM1A
P2-DIMM1B
CPU2
A
Slot7 PCI-E 2.0 X8
Slot6 PCI-E 2.0 X8
Slot5 PCI-E 2.0 X8
JI2C2
JI2C1
Slot4 PCI-E 2.0 X8
Slot3 PCI-E 2.0 X8
Slot2 PCI-E 2.0 X8
Slot1 PCI-E 2.0 X8
JPG1
JPB
(South Bridge)
USB3
USB4/5
USB6/7
(IOH36D-2)
Intel
ICH10R
SATA-SGPIO1 SATA-SGPIO0
J7
JPI2C
CPU1
P1-DIMM1B
P1-DIMM1A
P1-DIMM2B
P1-DIMM2A
P1-DIMM3B
P1-DIMM3A
Intel
5520
Intel
5520
(IOH36D-1)
JBT1
I-SATA5
I-SATA4
SPI BIOS
I-SATA3
I-SATA2
LED5
SAS Activity
I-SATA1
JPW1
X8DTH
Rev. 1.01
J*
DP6 DP7
JPS1
I-SATA0
RAID Key
LSI SAS2008
JPW2
JPW3
PWR_LED
DP4
Battery
SAS
FLASH
SAS0~3
SAS4~7
FAN4
B. Dedicated LAN LEDs
FAN1
(X8DTH-iF/6F)
FAN7
JF1
JWD
FAN2
SMBus1
JOH1
JD1
FAN3
Buzzer
JL1
2-29
Page 52
X8DTH-6/X8DTH-6F/X8DTH-i/X8DTH-iF User's Manual
BMC Activity LED (X8DTH-iF/6F)
A BMC He artbe at LED i s lo c ated at D P5 on the motherboard. When DP5 is on, BMC (Baseboard Management Control­ler) is active. See the table s at right for more information.
SAS Activity LED (X8DTH-6/6F)
A SAS Act ivity LED is loc ated at LED5. When LED5 is on, SAS is active. Refer to the table on the right for details. Also see the layout b elow fo r the LED l ocat ion.
BMC Activity LED Indicator
LED Settings
Green: On BMC is active
SAS Activity LED Indicator
LED Settings
Green: On SAS is active
A. BMC Activity LED
FAN5
KB/MS
FAN6
USB0/1
IPMI_LAN
COM1
VGA
PHY
LAN1
LAN2
FAN8
JPL1
LAN CTRL
BMC
A
DP5
P2-DIMM3A
P2-DIMM3B
P2-DIMM2A
P2-DIMM2B
P2-DIMM1A
P2-DIMM1B
CPU2
Slot7 PCI-E 2.0 X8
Slot6 PCI-E 2.0 X8
Slot5 PCI-E 2.0 X8
JI2C2
JI2C1
Slot4 PCI-E 2.0 X8
Slot3 PCI-E 2.0 X8
Slot2 PCI-E 2.0 X8
Slot1 PCI-E 2.0 X8
JPG1
JPB
(South Bridge)
USB3
USB4/5
USB6/7
(IOH36D-2)
Intel
ICH10R
SATA-SGPIO1 SATA-SGPIO0
J7
JPI2C
CPU1
P1-DIMM1B
P1-DIMM1A
P1-DIMM2B
P1-DIMM2A
P1-DIMM3B
P1-DIMM3A
Intel
5520
Intel
5520
(IOH36D-1)
JBT1
I-SATA5
I-SATA4
SPI BIOS
I-SATA2
I-SATA3
SAS Activity
I-SATA1
LED5
JPW1
X8DTH
Rev. 1.01
B
DP6
DP7
JPS1
I-SATA0
JPW2
JPW3
FAN1
FAN7
JF1
PWR_LED
DP4
JWD
FAN2
SMBus1
JOH1
FAN3
Battery
Buzzer
SAS FLASH
J*
LSI SAS2008
RAID Key
SAS0~3
SAS4~7
FAN4
JL1
B. SAS Activity LED
JD1
2-30
Page 53
Chapter 2: Installation
SAS Heartbeat LED (X8DTH-6/6F)
A SAS Heartb eat L ED i s lo c ate d at D P 6. When DP6 is on, SAS functions normally. Refer to the t abl e on t he r ig ht for d eta ils . Also see the layout below for the LED location.
SAS Error LED (X8DTH-6/6F)
A SAS Activity LED is located at DP7. When DP 7 is on, an erro r has occur red with SA S co nn ec ti on s. Refe r to th e ta bl e on the right for details. Also see the layout below fo r the LED l oca tion.
SAS Heartbeat LED Indicator
Settings
LED Defi nition Green: On SAS: Normal
SAS Error LED Indicator
LED Settings
Red: On SAS error occurs
A. SAS Heartbeat LED
FAN5
KB/MS
FAN6
USB0/1
IPMI_LAN
COM1
VGA
PHY
LAN1
LAN2
FAN8
JPL1
LAN CTRL
BMC
DP5
P2-DIMM3A
P2-DIMM3B
P2-DIMM2A
P2-DIMM2B
P2-DIMM1A
P2-DIMM1B
CPU2
Slot7 PCI-E 2.0 X8
Slot6 PCI-E 2.0 X8
Slot5 PCI-E 2.0 X8
JI2C2
JI2C1
Slot4 PCI-E 2.0 X8
Slot3 PCI-E 2.0 X8
Slot2 PCI-E 2.0 X8
Slot1 PCI-E 2.0 X8
JPG1
JPB
(South Bridge)
USB3
USB4/5
USB6/7
(IOH36D-2)
Intel
ICH10R
SATA-SGPIO1 SATA-SGPIO0
J7
JPI2C
CPU1
P1-DIMM1B
P1-DIMM1A
P1-DIMM2B
P1-DIMM2A
P1-DIMM3B
P1-DIMM3A
Intel
5520
Intel
5520
(IOH36D-1)
JBT1
I-SATA5
I-SATA4
SPI BIOS
I-SATA3
I-SATA2
LED5
SAS Activity
I-SATA1
JPW1
X8DTH
Rev. 1.01
J*
A
DP6 DP7
B
JPS1
I-SATA0
RAID Key
LSI SAS2008
JPW2
JPW3
FAN1
FAN7
JF1
PWR_LED
DP4
JWD
FAN2
SMBus1
JOH1
FAN3
Battery
Buzzer
SAS
FLASH
SAS0~3
SAS4~7
FAN4
JL1
B. SAS Error LED
JD1
2-31
Page 54
X8DTH-6/X8DTH-6F/X8DTH-i/X8DTH-iF User's Manual
Onboard Power LED
An Onboard Power LED is located at DP4 on the motherboard. When this LED is on, the system is on. Be sure to turn off the system and unplug the power cord before removing or installing components. See the tables at right for more information.
Onboard PWR LED
Settings
LED Color Defi nition Off System Off (PWR cable
not connected)
Green System Power On
A. Onboard PWR LED
FAN5
KB/MS
FAN6
USB0/1
IPMI_LAN
COM1
VGA
PHY
LAN1
LAN2
FAN8
JPL1
LAN CTRL
BMC
DP5
P2-DIMM3A
P2-DIMM3B
P2-DIMM2A
P2-DIMM2B
P2-DIMM1A
P2-DIMM1B
CPU2
Slot7 PCI-E 2.0 X8
Slot6 PCI-E 2.0 X8
Slot5 PCI-E 2.0 X8
JI2C2
JI2C1
Slot4 PCI-E 2.0 X8
Slot3 PCI-E 2.0 X8
Slot2 PCI-E 2.0 X8
Slot1 PCI-E 2.0 X8
JPG1
JPB
(South Bridge)
USB3
USB4/5
USB6/7
(IOH36D-2)
Intel
ICH10R
SATA-SGPIO1 SATA-SGPIO0
J7
JPI2C
CPU1
P1-DIMM1B
P1-DIMM1A
P1-DIMM2B
P1-DIMM2A
P1-DIMM3B
P1-DIMM3A
Intel
5520
Intel
5520
(IOH36D-1)
JBT1
I-SATA5
I-SATA4
SPI BIOS
I-SATA2
I-SATA3
SAS Activity
I-SATA1
LED5
JPW1
X8DTH
Rev. 1.01
DP6
DP7
JPS1
I-SATA0
JPW2
JPW3
FAN1
FAN7
JF1
PWR_LED
DP4
A
JWD
FAN2
SMBus1
JOH1
JD1
FAN3
Battery
Buzzer
SAS FLASH
J*
LSI SAS2008
RAID Key
SAS0~3
SAS4~7
FAN4
JL1
2-32
Page 55
Chapter 2: Installation
F
G
2-9 SATA and SAS Connections
Note the following conditions when connecting the Serial ATA and fl oppy disk drive cables:
• Be sure to use the correct cable for each connector. Refer to Page 1-1 for cables
that came with your shipment.
• A red mark on a wire indicates the location of pin 1.
SATA/SAS Connections (SAS: X8DTH-6/6F)
Six Serial ATA (SATA) connectors (I-SATA 0~5) are located on the motherboard. In addition to six SATA ports, eight SAS connections are also located on the X8DTH-6/6F. These Serial Link connections provide faster data transmission than the connections of traditional Parallel ATA. The SATA connectors are supported by the Intel ICH10R. The SAS connectors on the X8DTH­6/6F are supported by the LSI SAS 2 controller. See the table on the right for pin defi nitions.
SATA/SAS Connectors
Pin Defi nitions
Pin# Signal 1 Ground 2 SATA_TXP 3 SATA_TXN 4 Ground 5 SATA_RXN 6 SATA_RXP 7 Ground
Notes: 1. For SATA RAID Confi guration instructions, please refer to the Intel SATA HostRAID User's Guide posted on our website @ http://www. supermicro.com/support/manuals/.
2. For instructions on SAS RAID confi guration, please refer to the LSI MegaRAID User's Guide posted on our website @ http://www.supermicro. com/support/manuals/.
FAN5
KB/MS
FAN6
USB0/1
IPMI_LAN
COM1
VGA
PHY
LAN1
LAN2
FAN8
JPL1
LAN CTRL
BMC
DP5
P2-DIMM3A
P2-DIMM3B
P2-DIMM2A
P2-DIMM2B
P2-DIMM1A
P2-DIMM1B
CPU2
Slot7 PCI-E 2.0 X8
Slot6 PCI-E 2.0 X8
Slot5 PCI-E 2.0 X8
JI2C2
JI2C1
Slot4 PCI-E 2.0 X8
Slot3 PCI-E 2.0 X8
Slot2 PCI-E 2.0 X8
Slot1 PCI-E 2.0 X8
JPG1
JPB
(South Bridge)
USB3
USB4/5
USB6/7
(IOH36D-2)
Intel
ICH10R
SATA-SGPIO1 SATA-SGPIO0
J7
JPI2C
JPW2
JPW1
JPW3
A~F. SATA0~5
FAN1
G. SATA0~3 (X8DTH-6/6F) H. SATA4~7 (X8DTH-6/6F)
CPU1
P1-DIMM1B
P1-DIMM1A
P1-DIMM2B
P1-DIMM2A
P1-DIMM3B
P1-DIMM3A
X8DTH
I-SATA3
I-SATA2
Rev. 1.01
Intel
5520
(IOH36D-1)
LED5
J*
SAS Activity
DP6
E
A
LSI
DP7
SAS2008
JPS1
I-SATA1
RAID Key
I-SATA0
D
C
Intel
5520
JBT1
SPI BIOS
I-SATA5
I-SATA4
B
FAN7
JF1
PWR_LED
DP4
JWD
FAN2
SMBus1
JOH1
JD1
FAN3
Battery
Buzzer
SAS
FLASH
SAS0~3
H
SAS4~7
FAN4
JL1
2-33
Page 56
X8DTH-6/X8DTH-6F/X8DTH-i/X8DTH-iF User's Manual
Notes
2-34
Page 57
Chapter 3: Troubleshooting
Chapter 3
Troubleshooting
3-1 Troubleshooting Procedures
Use the following procedures to troubleshoot your system. If you have followed all of the procedures below and still need assistance, refer to the ‘Technical Support Procedures’ and/or ‘Returning Merchandise for Service’ section(s) in this chapter. Note: Always disconnect the power cord before adding, changing or installing any hardware components.
Before Power On
Make sure that there are no short circuits between the motherboard and 1. chassis.
Disconnect all ribbon/wire cables from the motherboard, including those for 2. the keyboard and mouse.
Remove all add-on cards.3.
Install CPU 1 fi rst (making sure it is fully seated) and connect the chassis 4. speaker and the power LED to the motherboard. (Check all jumper settings as well.)
No Power
Make sure that there are no short circuits between the motherboard and the 1. chassis.
Make sure that all jumpers are set to their default positions.2.
Check that the 115V/230V switch on the power supply is properly set.3.
Turn the power switch on and off to test the system.4.
The battery on your motherboard may be old. Check to verify that it still sup-5. plies ~3VDC. If it does not, replace it with a new one.
3-1
Page 58
X8DTH-6/X8DTH-6F/X8DTH-i/X8DTH-iF User's Manual
No Video
If the power is on but you have no video, remove all the add-on cards and 1. cables.
Use the speaker to determine if any beep codes exist. Refer to the Appendix 2. for details on beep codes.
Losing the System’s Setup Confi guration
Make sure that you are using a high quality power supply. A poor quality 1. power supply may cause the system to lose the CMOS setup information. Refer to Section 1-6 for details on recommended power supplies.
The battery on your motherboard may be old. Check to verify that it still sup-2. plies ~3VDC. If it does not, replace it with a new one.
If the above steps do not fi x the Setup Confi guration problem, contact your 3. vendor for repairs.
Memory Errors
When a No_Memory_Beep_Code is issued by the system, check the following:
Make sure that the DIMM modules are properly and fully installed. 1.
Check if different speeds of DIMMs have been installed and check if the BIOS 2. setup is confi gured for the fastest speed of RAM used. (It is recommended to use the same RAM speed for all DIMMs in the system.)
Make sure you are using the correct type of Registered ECC or Unbuffered 3. ECC/Non-ECC DDR3 1333/1066/800 MHz SDRAM (recommended by the manufacturer.)
Check for bad DIMM modules or slots by swapping a single module between 4. all memory slots and check the results.
Make sure that all memory modules are fully seated in their slots. Make sure 5. to follow the instructions given on DIMM population in Section 2-4 in Chapter
2.
Check the position of the 115V/230V switch on the power supply.6.
Please follow the instructions given in the DIMM Population Tables listed on 7. Pages 2-7 and 2-8 to install your memory modules.
3-2
Page 59
Chapter 3: Troubleshooting
3-2 Technical Support Procedures
Before contacting Technical Support, please take the following steps. Also, please note that as a motherboard manufacturer, Supermicro does not sell directly to end­users, so it is best to fi rst check with your distributor or reseller for troubleshooting services. They should know of any possible problem(s) with the specifi c system confi guration that was sold to you.
Please go through the ‘Troubleshooting Procedures’ and 'Frequently Asked 1. Question' (FAQ) sections in this chapter or see the FAQs on our website (
http://www.supermicro.com/support/faqs/) before contacting Technical Sup-
port.
BIOS upgrades can be downloaded from our website at 2.
cro.com/support/bios/
If you still cannot resolve the problem, include the following information when 3. contacting Supermicro for technical support:
Motherboard model and PCB revision number
BIOS release date/version (this can be seen on the initial display when your system fi rst boots up)
System confi guration
An example of a Technical Support form is on our website at (http://www.super-
micro.com/support/contact.cfm).
Distributors: For immediate assistance, please have your account number ready
when placing a call to our technical support department. We can be reached by e-mail at support@supermicro.com or by fax at: (408) 503-8000, option 2.
).
(http://www.supermi-
3-3 Frequently Asked Questions
Que sti on: Wh at a re th e var iou s t ype s of m emo r y th at my mo th er boa rd c an support?
Answer: The X8DTH-6/X8DTH-6F/X8DTH-i/X8DTH-iF has 12 240-pin DIMM slots
that support up to 96 GB of Reg. ECC or up to 24 GB of Unbuffered ECC/Non-ECC DDR3 1333/1066/800 MHz SDRAM modules. It is strongly recommended that you do not mix memory modules of different speeds and sizes. Please follow all memory installation instructions given on Section 2-4 in Chapter 2.
3-3
Page 60
X8DTH-6/X8DTH-6F/X8DTH-i/X8DTH-iF User's Manual
Que stio n: How do I u pda te my BI OS? Answer: It is recommended that you do not upgrade your BIOS if you are not
experiencing any problems with your system. Updated BIOS fi les are located on our web site at warning message and the information on how to update your BIOS on our web site. Select your motherboard model and download the BIOS fi le to your computer. Also, check the current BIOS revision and make sure that it is newer than your BIOS before downloading. You can choose from the zip fi le and the .exe fi le. If you choose the zip BIOS fi le, please unzip the BIOS fi le onto a bootable USB device. Run the batch fi le using the format fl ash.bat fi lename.rom from your bootable USB device to fl ash the BIOS. Then, your system will automatically reboot. Please note that this process may take a few minutes to complete. Do not be concerned if the screen is paused for a few minutes.
http://www.supermicro.com/support/bios/. Please check our BIOS
Warning: Do not shut down or reset the system while updating the BIOS
to prevent possible system boot failure!
Note: The SPI BIOS chip used on this motherboard cannot be removed.
Send your motherboard back to our RMA Department for repair.
Question: What's on the CD that came with my motherboard? Answer: The supplied CD has drivers and programs that are needed for your sys-
tem. Please r eview t h e C D and i ns t al l th e ap pl ication s you n ee d. A p p lication s on the CD inc lude c hipset d river s for th e Wind ows OS, se cur ity an d audio dr iver s.
3-4 Returning Merchandise for Service
A receipt or copy of your invoice marked with the date of purchase is required be­fore any warranty service will be rendered. You can obtain service by calling your vendor for a Returned Merchandise Authorization (RMA) number. When returning to the manufacturer, the RMA number should be prominently displayed on the outside of the shipping carton, and mailed prepaid or hand-carried. Shipping and handling charges will be applied for all orders that must be mailed when service is complete. For faster service, You can also request a RMA authorization online (http://www. supermicro.com/support/rma/).
This warranty only covers normal consumer use and does not cover damages in­curred in shipping or from failure due to the alternation, misuse, abuse or improper maintenance of products.
During the warranty period, contact your distributor fi rst for any product problems.
3-4
Page 61
Chapter 4: AMI BIOS
Chapter 4
BIOS
4-1 Introduction
This chapter describes the AMI BIOS Setup Utility for the X8DTH-6/X8DTH-6F/ X8DTH-i/X8DTH-iF. The AMI ROM BIOS is stored in a Flash EEPROM and can be easily updated. This chapter describes the basic navigation of the AMI BIOS Setup Utility setup screens.
Starting BIOS Setup Utility
To enter the AMI BIOS Setup Utility screens, press the <Delete> key while the system is booting up.
Note: In most cases, the <Delete> key is used to invoke the AMI BIOS setup screen. There are a few cases when other keys are used, such as <F1>, <F2>, etc.
Each main BIOS menu option is described in this manual. The Main BIOS setup menu screen has two main frames. The left frame displays all the options that can be confi gured. Grayed-out options cannot be confi gured. Options in blue can be confi gured by the user. The right frame displays the key legend. Above the key legend is an area reserved for a text message. When an option is selected in the left frame, it is highlighted in white. Often a text message will accompany it. (Note: the AMI BIOS has default text messages built in. Supermicro retains the option to include, omit, or change any of these text messages.)
The AMI BIOS Setup Utility uses a key-based navigation system called "hot keys". Most of the AMI BIOS setup utility "hot keys" can be used at any time during the setup navigation process. These keys include <F1>, <F10>, <Enter>, <ESC>, ar­row keys, etc.
Note: Options printed in Bold are default settings.
How To Change the Confi guration Data
The confi guration data that determines the system parameters may be changed by entering the AMI BIOS Setup utility. This Setup utility can be accessed by pressing <Del> at the appropriate time during system boot.
4-1
Page 62
X8DTH-6/X8DTH-6F/X8DTH-i/X8DTH-iF User's Manual
Starting the Setup Utility
Normally, the only visible Power-On Self-Test (POST) routine is the memory test. As the memory is being tested, press the <Delete> key to enter the main menu of the AMI BIOS Setup Utility. From the main menu, you can access the other setup screens. An AMI BIOS identifi cation string is displayed at the left bottom corner of the screen below the copyright message.
Warning! Do not upgrade the BIOS unless your system has a BIOS-related issue. Flashing the wrong BIOS can cause irreparable damage to the system. In no event shall Supermicro be liable for direct, indirect, special, incidental, or consequential damages arising from a BIOS update. If you have to update the BIOS, do not shut down or reset the system while the BIOS is updating. This is to avoid possible boot failure.
4-2 Main Setup
When you fi rst enter the AMI BIOS Setup Utility , you will enter the Main setup screen. You can always return to the Main setup screen by selecting the Main tab on the top of the screen. The Main BIOS Setup screen is shown below.
System Overview: The following BIOS information will be displayed:
System Time/System Date
Use this option to change the system time and date. Highlight System Time or Sys­tem Date using the arrow keys. Key in new values through the keyboard and press
<Enter>. Press the <Tab> key to move between fi elds. The date must be entered in Day MM/DD/YY format. The time is entered in HH:MM:SS format. (Note: The time is in the 24-hour format. For example, 5:30 P.M. appears as 17:30:00.)
4-2
Page 63
Chapter 4: AMI BIOS
Supermicro X8DTH
Version
: This item displays the BIOS revision used in your system.
Build Date
: This item displays the date when this BIOS was completed.
Processor
The AMI BIOS will automatically display the status of the processor used in your system:
CPU Type
: This item displays the type of CPU used in the motherboard.
Speed
: This item displays the speed of the CPU detected by the BIOS.
Physical Count
: This item displays the number of processors installed in your
system as detected by the BIOS.
Logical Count
: This item displays the number of CPU Cores installed in your
system as detected by the BIOS.
System Memory
This displays the size of memory available in the system:
Populated Size
: This item displays the installed memory size detected by the
BIOS.
Available Size
: This item displays the available memory detected by the
BIOS.
4-3
Page 64
X8DTH-6/X8DTH-6F/X8DTH-i/X8DTH-iF User's Manual
4-3 Advanced Setup Confi gurations
Use the arrow keys to select Advanced Setup and hit <Enter> to access the sub­menu items:
BOOT Features
Quick Boot
If Enabled, this option will skip certain tests during POST to reduce the time needed for system boot. The options are Enabled and Disabled.
Quiet Boot
This option allows the bootup screen options to be modifi ed between POST mes- sages or the OEM logo. Select Disabled to display the POST messages. Select Enabled to display the OEM logo instead of the normal POST messages. The op­tions are Enabled and Disabled.
AddOn ROM Display Mode
This sets the display mode for Option ROM. The options are Force BIOS and Keep Current.
Bootup Num-Lock
This feature selects the Power-on state for Numlock key. The options are Off and On.
PS/2 Mouse Su ppor t
This feature enables support for the PS/2 mouse. The options are Disabled, Enabled and Auto.
4-4
Page 65
Chapter 4: AMI BIOS
Wait For 'F1' If Error
This for ce s the sys tem to wai t until t he ' F1' key is pressed i f an er ror o cc urs . The option s are Dis able d and Enabled.
Hit 'Del' Message Display
This feature displays "Press DEL to run Setup" during POST. The options are
Enabled and Disabled.
Watch Dog Function
If enable d, the Watch Do g Timer wil l a l l o w the system to reboot when i t i s i n a ctive for more t han 5 minu tes. The o ption s are Enabl ed and Disabled.
Power Button Function
If set to Instant_Off, the system will power off immediately as soon as the user hits the power button. If set to 4_Second_Override, the system will power off when the user presses the power button for 4 seconds or longer. The options are Instant_Off and 4_Second_Override.
Restore on AC Power Loss
Use this feature to set the power state after a power outage. Select Power-Off for the system power to remain off after a power loss. Select Power-On for the system power to be turned on after a power loss. Select Last State to allow the system to resume its last state before a power loss. The options are Power-On, Power-Off and Last State.
Interrupt 19 Capture
Interrupt 19 is the software interrupt that handles the boot disk function. When this item is set to Enabled, the ROM BIOS of the host adaptors will "capture" Interrupt 19 at boot and allow the drives that are attached to these host adaptors to function as bootable disks. If this item is set to Disabled, the ROM BIOS of the host adap­tors will not capture Interrupt 19, and the drives attached to these adaptors will not function as bootable devices. The options are Enabled and Disabled.
4-5
Page 66
X8DTH-6/X8DTH-6F/X8DTH-i/X8DTH-iF User's Manual
Processor and Clock Options
This submenu allows the user to confi gure the Processor and Clock settings.
CPU Ratio
If set to Manual, this option allows the user to set the ratio between the CPU Core Clock and the FSB Frequency. (Note: if an invalid ratio is entered, the AMI BIOS will restore the setting to the previous state.) The options are Auto and Manual.
Ratio CMOS Setting (Available when the item-CPU Ratio is set to Manual)
Press "+" or "-" on your keyboard to set the ratio between the CPU Core clock and the FSB Frequency. The default setting for the CPU installed in your moth­erboard is [18].
Clock Spread Spectrum
Select Enable to use the feature of Clock Spectrum, which will allow the BIOS to monitor and attempt to reduce the level of Electromagnetic Interference caused by the components whenever needed. The options are Disabled and Enabled.
Hardware Prefetcher (Available when supported by the CPU)
If set to Enabled, the hardware prefetcher will prefetch streams of data and instruc­tions from the main memory to the L2 cache in the forward or backward manner to improve CPU performance. The options are Disabled and Enabled.
Adjacent Cache Line Prefetch (Available when supported by the CPU)
The CPU fetches the cache line for 64 bytes if this option is set to Disabled. The CPU fetches both cache lines for 128 bytes as comprised if Enabled.
Intel® Virtualization Technology (Available when supported by the CPU)
Select Enabled to use the feature of Virtualization Technology to allow one platform to run multiple operating systems and applications in independent partitions, creat­ing mult iple " vi r tu al" sy stems i n one p hysic al c o mput er. The opti ons ar e Enabled and Dis abled. Not e: If there is any change to this setting, you will need to power off an d restart the sy s t e m for the change to ta ke effec t. Please re f e r t o Intel’s web site for detailed information.
Execute-Disable Bit Capability (Available when supported by the OS and the CPU)
Set to Enabled to enable the Execute Disable Bit which will allow the processor to designate areas in the system memory where an application code can execute and where it cannot, thus preventing a worm or a virus from fl ooding illegal codes to overwhelm the processor or damage the system during an attack. The default is Enabled. (Refer to Intel and Microsoft Web Sites for more information.)
4-6
Page 67
Chapter 4: AMI BIOS
Simultaneous Multi-Threading (Available when supported by the CPU)
Set to Enabled to use the Simultaneous Multi-Threading Technology, which will result in increased CPU performance. The options are Disabled and Enabled.
Active Processor Cores
Set to Enabled to use a processor's Second Core and beyond. (Please refer to Intel's web site for more information.) The options are All, 1 and 2.
Intel® EIST Technology
EIST (Enhanced Intel SpeedStep Technology) allows the system to automatically adjust processor voltage and core frequency in an effort to reduce power consump­tion and heat dissipation. Please refer to Intel’s web site for detailed information. The options are Disabled and Enabled.
Intel® TurboMode Technology (Available when Intel® EIST Technology is enabled)
Select Enabled to use the Turbo Mode to boost system performance. The options are Enabled and Disabled.
C1E Support
Select Enabled to use the feature of Enhanced Halt State. C1E signifi cantly reduces the CPU's power consumption by reducing the CPU's clock cycle and voltage during a "Halt State." The options are Disabled and Enabled.
Intel® C-STATE Tech
If enabled, C-State is set by the system automatically to either C2, C3 or C4 state. The options are Disabled and Enabled.
C-State package limit setting (Available when Intel® C-State Tech is enabled)
If set to Auto, the AMI BIOS will automatically set the limit on the C-State package register. The options are Auto, C1, C3, C6 and C7.
C3 State
This feature allows the user to set the C3 State for the 5000 Series Processor. The options are Disabled, ACPI 2 and ACPI 3.
C6 State
This feature allows the user to set the C6 State for the 5000 Series Processor. The options are Disabled and Enabled.
4-7
Page 68
X8DTH-6/X8DTH-6F/X8DTH-i/X8DTH-iF User's Manual
C1 Auto Demotion
When enabled, the CPU will conditionally demote C3, C6 or C7 requests to C1 based on un-core auto-demote information. The options are Disabled and Enabled.
C3 Auto Demotion
When enabled, the CPU will conditionally demote C6 or C7 requests to C3 based on un-core auto-demote information. The options are Disabled and Enabled.
ACPI T State
Select Enabled to report Processor throttling in the ACPI. The options are Disabled and Enabled.
DCA Technology
This feature accelerates the performance of TOE devices. Note: A TOE device is a specialized, dedicated processor that is installed on an add-on card or a network card to handle some or all packet processing of this add-on card. For this moth­erboard, the TOE device is built inside the ESB 2 South Bridge chip. This feature is supported only by some types of processors (i.e., Intel Nehalem-WS 1S). The
options are Enabled and Disabled.
DCA Prefetch Delay
A DCA Prefetch is used with TOE components to prefetch data in order to shorten execution cycles and maximize data processing effi ciency. Prefetching too fre- quently can saturate the cache directory and delay necessary cache accesses. This feature reduces or increases the frequency the system prefetches data. The options are [8], [16], [32], [40], [48], [56], [64], [72], [80], [88], [96], [104], [112], [120]
Advanced Chipset Control
The items included in the Advanced Settings submenu are listed below:
QPI & IMC Confi guration
QPI Links Speed
This feature selects QPI's data transfer speed. The options are Slow-mode, and
Full Speed.
QPI Frequency
This selects the desired QPI frequency. The options are Auto, 4.800 GT,
5.866GT, 6.400 GT.
4-8
Page 69
Chapter 4: AMI BIOS
QPI L0s and L1
This enables the QPI power state to low power. L0s and L1 are automatically selected by the motherboard. The options are Disabled and Enabled.
Memory Frequency
This feature forces a DDR3 frequency slower than what the system has detected. The available options are Auto, Force DDR-800, Force DDR-1066, and Force DDR-1333.
Memory Mode
The options are Independent, Channel Mirror, and Lockstep. Independent - All DIMMs are available to the operating system. Channel Mirror - The motherboard maintains two identical copies of all data in
memory for redundancy. Lockstep - The motherboard uses two areas of memory to run the same set of
operations in parallel. Sparing - A preset threshold of correctable errors is used to trigger fail-over.
The spare memory is put online and used as active memory in place of the failed memory.
Demand Scrubbing
A memory error-correction scheme where the Processor writes corrected data back into the memory block from where it was read by the Processor. The op­tions are Enabled and Disabled.
Patrol Scrubbing
A memory error-correction scheme that works in the background looking for and correcting resident errors. The options are Enabled and Disabled.
Throttling - Closed Loop / Throttling - Open Loop
Throttling improves reliability and reduces power in the processor by automatic voltage control during processor idle states. Available options are Disabled and Enabled. If Enabled, the following items will appear:
Hysteresis Temperature (Closed Loop only)
Temperature Hysteresis is the temperature lag (in degrees Celsius) after the set DIMM temperature threshold is reached before Closed Loop Throttling begins. The options are Disabled, 1.5oC, 3.0
4-9
o
C, and 6.0oC.
Page 70
X8DTH-6/X8DTH-6F/X8DTH-i/X8DTH-iF User's Manual
Guardband Temperature (Closed Loop only)
This is the temperature which applies to the DIMM temperature threshold. Each step is in 0.5
o
C increment. The default is [006]. Press "+" or "-" on
your keyboard to change this value.
Inlet Temperature
This is the temperature detected at the chassis inlet. Each step is in 0.5 increment. The default is [070]. Press "+" or "-" on your keyboard to change this value.
Temperature Rise
This is the temperature rise to the DIMM thermal zone. Each step is in
o
0.5
C increment. The default is [020]. Press "+" or "-" on your keyboard to
change this value.
Air Flow
This is the air fl ow speed to the DIMM modules. Each step is one mm/ sec. The default is [1500]. Press "+" or "-" on your keyboard to change this value.
o
C
Altitude
This feature defi nes how many meters above or below sea level the system is located. The options are Sea Level or Below, 1~300, 301~600, 601~900, 901~1200, 1201~1500, 1501~1800, 1801~2100, 2101~2400, 2401~2700, 2701~3000.
DIMM Pitch
This is the physical space between each DIMM module. Each step is in 1/1000 of an inch. The default is [400]. Press "+" or "-" on your keyboard to change this value.
Intel VT-d
Select Enabled to enable Intel's Virtualization Technology support for Direct I/O VT-d by reporting the I/O device assignments to VMM through the DMAR ACPI Tables. This feature offers fully-protected I/O resource-sharing across the Intel platforms, providing the user with greater reliability, security and availability in networking and data-sharing. The settings are Enabled and Disabled.
SR-IOV Support
Single Root I/O Virtualization is an industry-standard mechanism that allow devices to advertise their capability to be simultaneously shared among several virtual machines. SR-IOV is capable of partitioning a PCI function into several virtual
4-10
Page 71
Chapter 4: AMI BIOS
interfaces for sharing the resources of a PCI Express (PCIe) device under a virtual environment. The options are Disabled and Enabled.
NUMA Support
Select Enabled to use the feature of Non-Uniform Memory Access to improve CPU performance. The options are Enabled and Disabled.
Intel I/OAT
The Intel I/OAT (I/O Acceleration Technology) signifi cantly reduces CPU overhead by leveraging CPU architectural improvements, freeing resources for more other tasks. The options are Disabled and Enabled.
Active State Power Management
Selec t Enabled to star t Active -State Powe r Management fo r signal trans actions betwe en L0 an d L1 Links on the PCI E xp re s s Bus . Th is ma x im ize s powe r-s avin g and tran sact ion spe ed. The o ption s are Enabl ed and Disabled.
USB Functions
This feature allows the user to decide the number of onboard USB ports to be en­abled. The Options are: Disabled, 2 USB ports, 4 USB ports, 6 USB ports, 8 USB ports, 10 USB ports and 12 USB ports.
USB 2.0 Controller
This featu re displays t he cur rent US B contr oller u sed in the m other boar d.
Legacy USB Support
Select Enabled to use Legacy USB devices. If this item is set to Auto, Legacy USB support will be automatically enabled if a legacy USB device is installed on the motherboard, and vise versa. The settings are Disabled, Enabled and Auto.
IDE/SATA Con guration
When this submenu is selected, the AMI BIOS automatically detects the presence of the IDE devices and displays the following items:
SATA#1 Confi guration
If Compatible is selected, it sets SATA#1 to legacy compatibility mode, while se­lecting Enhanced sets SATA#1 to native SATA mode. The options are Disabled, Compatible and Enhanced.
Confi gure SATA#1 as
This feature allows the user to select the drive type for SATA#1. The options are IDE, RAID and AHCI. (When the option-RAID is selected, the item-ICH RAID
4-11
Page 72
X8DTH-6/X8DTH-6F/X8DTH-i/X8DTH-iF User's Manual
Code Base will appear. When the option-AHCI is selected, the item-SATA AHCI will be available.)
ICH RAID Code Base (This feature is available when the option-RAID is selected)
Select Intel to enable Intel's SATA RAID fi rmware to confi gure Intel's SATA RAID settings. Select Adaptec to enable Adaptec's SATA RAID fi rmware to confi gure Adaptec's SATA RAID settings. The options are Intel and Adaptec.
SATA#2 Confi guration (This feature is available when the option-IDE is selected for SATA#1)
Selecting Enhanced will set SA T A#2 to native SA TA mode. The options are Disabled, and Enhanced.
IDE Detect Timeout (sec)
Use this feature to set the time-out value for the BIOS to detect the ATA, ATAPI devices installed in the system. The options are 0 (sec), 5, 10, 15, 20, 25, 30, and
35.
Primary IDE Master/Slave, Secondary IDE Master/Slave, Third IDE Master, and Fourth IDE Master
These settings allow the user to set the parameters of Primary IDE Master/Slave, Secondary IDE Master/Slave, Third and Fourth IDE Master slots. Hit <Enter> to activate the following submenu screen for detailed options of these items. Set the correct confi gurations accordingly. The items included in the submenu are:
Type
Select the type of device connected to the system. The options are Not Installed,
Auto, CD/DVD and ARMD.
LBA/Large Mode
LBA (Logical Block Addressing) is a method of addressing data on a disk drive. In the LBA mode, the maximum drive capacity is 137 GB. For drive capacities over 137 GB, your system must be equipped with a 48-bit LBA mode addressing. If not, contact your manufacturer or install an ATA/133 IDE controller card that supports 48-bit LBA mode. The options are Disabled and Auto.
Block (Multi-Sector Transfer)
Block Mode boosts the IDE drive performance by increasing the amount of data transferred. Only 512 bytes of data can be transferred per interrupt if Block Mode is not used. Block Mode allows transfers of up to 64 KB per interrupt. Select Disabled to allow data to be transferred from and to the device one sector at
4-12
Page 73
Chapter 4: AMI BIOS
a time. Select Auto to allow data transfer from and to the device occur multiple sectors at a time if the device supports it. The options are Auto and Disabled.
PIO Mode
The IDE PIO (Programmable I/O) Mode programs timing cycles between the IDE drive and the programmable IDE controller. As the PIO mode increases, the cycle time decreases. The options are Auto, 0, 1, 2, 3, and 4.
Select Auto to allow the AMI BIOS to automatically detect the PIO mode. Use this value if the IDE disk drive support cannot be determined.
Select 0 to allow the AMI BIOS to use PIO mode 0. It has a data transfer rate of 3.3 MBs.
Select 1 to allow the AMI BIOS to use PIO mode 1. It has a data transfer rate of 5.2 MBs.
Select 2 to allow the AMI BIOS to use PIO mode 2. It has a data transfer rate of 8.3 MBs.
Select 3 to allow the AMI BIOS to use PIO mode 3. It has a data transfer rate of 11.1 MBs.
Select 4 to allow the AMI BIOS to use PIO mode 4. It has a data transfer band­width of 32-Bits. Select Enabled to enable 32-Bit data transfer.
DMA Mode
Select Auto to allow the BIOS to automatically detect IDE DMA mode when the IDE disk drive support cannot be determined.
Select SWDMA0 to allow the BIOS to use Single Word DMA mode 0. It has a data transfer rate of 2.1 MBs.
Select SWDMA1 to allow the BIOS to use Single Word DMA mode 1. It has a data transfer rate of 4.2 MBs.
Select SWDMA2 to allow the BIOS to use Single Word DMA mode 2. It has a data transfer rate of 8.3 MBs.
Select MWDMA0 to allow the BIOS to use Multi Word DMA mode 0. It has a data transfer rate of 4.2 MBs.
Select MWDMA1 to allow the BIOS to use Multi Word DMA mode 1. It has a data transfer rate of 13.3 MBs.
Select MWDMA2 to allow the BIOS to use Multi-Word DMA mode 2. It has a data transfer rate of 16.6 MBs.
Select UDMA0 to allow the BIOS to use Ultra DMA mode 0. It has a data transfer rate of 16.6 MBs. It has the same transfer rate as PIO mode 4 and Multi Word DMA mode 2.
4-13
Page 74
X8DTH-6/X8DTH-6F/X8DTH-i/X8DTH-iF User's Manual
Select UDMA1 to allow the BIOS to use Ultra DMA mode 1. It has a data transfer rate of 25 MBs.
Select UDMA2 to allow the BIOS to use Ultra DMA mode 2. It has a data transfer rate of 33.3 MBs.
Select UDMA3 to allow the BIOS to use Ultra DMA mode 3. It has a data transfer rate of 66.6 MBs.
Select UDMA4 to allow the BIOS to use Ultra DMA mode 4. It has a data transfer rate of 100 MBs.
Select UDMA5 to allow the BIOS to use Ultra DMA mode 5. It has a data transfer rate of 133 MBs.
Select UDMA6 to allow the BIOS to use Ultra DMA mode 6. It has a data transfer rate of 133 MBs. The options are Auto, SWDMAn, MWDMAn, and UDMAn.
S.M.A.R.T. For Hard disk drives
Self-Monitoring Analysis and Reporting Technology (SMART) can help predict impending drive failures. Select Auto to allow the AMI BIOS to automatically de­tect hard disk drive support. Select Disabled to prevent the AMI BIOS from using the S.M.A.R.T. Select Enabled to allow the AMI BIOS to use the S.M.A.R.T. to support hard drive disk. The options are Disabled, Enabled, and Auto.
32Bit Data Transfer
Select Enable to enable the function of 32-bit IDE data transfer. The options are Enabled and Disabled.
PCI/PnP Confi guration
Clear NVRAM This feature clears the NVRAM during system boot. The options are No and Yes.
Plug & Play OS
Selecting Yes allows the OS to confi gure Plug & Play devices. (This is not required for system boot if your system has an OS that supports Plug & Play.) Select No to allow the AMI BIOS to confi gure all devices in the system.
PCI Latency Timer
This feature sets the latency Timer of each PCI device installed on a PCI bus. Select 64 to set the PCI latency to 64 PCI clock cycles. The options are 32, 64, 96, 128, 160, 192, 224 and 248.
4-14
Page 75
Chapter 4: AMI BIOS
PCI IDE BusMaster
When enabled, the BIOS uses PCI bus mastering for reading/writing to IDE drives. The options are Disabled and Enabled.
PCIe I/O Performance
Some add-on cards perform faster with the coalesce feature, which limits the pay­load size to 128 MB; while others, with a payload size of 256 MB which inhibits the coalesce feature. Please refer to your add-on card user guide for the desired setting. The options are 256 MB and 128MB.
PCI-E Slots 1~7 x8
This feature allows you to Enable or Disable any of the PCI slots. The options are Enable and Disable.
Load Onboard LAN1 Option ROM/Load Onboard LAN2 Option ROM
Selec t Enabled to enable the onboard LAN1 or LAN 2 Option ROM. This is to boot computer using a network interface. The options are Enabled and Disabled.
Load Onboard SAS Option ROM
Selec t En ab l e d to e na b le t h e o nb o ar d S A S O pt i o n RO M . T his is to boot computer using a network interface. The options are Enabled and Disabled.
Super IO Device Confi guration
Serial Port1 Address
This option specifi es the base I/O port address and the Interrupt Request address of Serial Port 1. Select Disabled to prevent the serial port from accessing any system resources. When this option is set to Disabled, the serial port physically becomes unavailable. Select 3F8/IRQ4 to allow the serial port to use 3F8 as its I/O port ad­dress and IRQ 4 for the interrupt address. The options are Disabled, 3F8/IRQ4, 3E8/IRQ4, 2E8/IRQ3 and 2F8/IRQ3.
Remote Access Confi guration
Remote Access
This allows the user to enable the Remote Access feature. The options are Disabled and Enabled.
If Remote Access is set to Enabled, the following items will display:
4-15
Page 76
X8DTH-6/X8DTH-6F/X8DTH-i/X8DTH-iF User's Manual
Serial Port Number
This feature allows the user decide which serial port to be used for Console Redi­rection. The options are COM 1 and COM 2.
Base Address, IRQ
This item displays the based address and IRQ of the serial port specifi ed above. The default setting for COM1 is 3F8/IRQ4, and for COM 2 is 2F8/IRQ3.
Serial Port Mode
This feature allows the user to set the serial port mode for Console Redirection. The options are 115200 8, n 1; 57600 8, n, 1; 38400 8, n, 1; 19200 8, n, 1; and 9600 8, n, 1.
Flow Control
This feature allows the user to set the fl ow control for Console Redirection. The options are None, Hardware, and Software.
Redirection After BIOS POST
Selec t Disabled to tur n off Console Re d i r ectio n a fter Power-On Se l f -Test (POST). Selec t Always to kee p Cons ole Re direc tio n acti ve all the t ime af ter P OST. (Note: This setting may not be supported by some operating systems.) Select Boot Loader to keep Con sole Redirec tion active du ring POST and B oot Loader. The option s are Disa bled, B oot Loade r, and Always.
Terminal Type
This feature allows the user to select the target terminal type for Console Redirec­tion. The options are ANSI, VT100, and VT-UTF8.
VT-UTF8 Combo Key Support
A terminal keyboard defi nition that provides a way to send commands from a remote console. Available options are Enabled and Disabled.
Sredir Memory Display Delay
This feature defi nes the length of time in seconds to display memory information. The options are No Delay, Delay 1 Sec, Delay 2 Sec, and Delay 4 Sec.
Hardware Health Monitor
This feature allows the user to monitor system health and review the status of each item as displayed.
4-16
Page 77
Chapter 4: AMI BIOS
CPU Overheat Alarm
This option allows the user to select the CPU Overheat Alarm setting which de­termines when the CPU OH alarm will be activated to provide warning of possible CPU overheat.
Warning! 1.Any temperature that exceeds the CPU threshold tempera­ture predefi ned by the CPU manufacturer may result in CPU overheat or system instability. When the CPU temperature reaches this predefi ned threshold, the CPU and system cooling fans will run at full speed. 2. To avoid possible system overheating, please be sure to provide adequate airfl ow to your system.
The options are:
The Early Alarm: Select this setting if you want the CPU overheat alarm (includ-
ing the LED and the buzzer) to be triggered as soon as the CPU temperature reaches the CPU overheat threshold as predefi ned by the CPU manufacturer.
The Default Alarm
: Select this setting if you want the CPU overheat alarm
(including the LED and the buzzer) to be triggered when the CPU temperature reaches about 5 manufacturer to give the CPU and system fans additional time needed for CPU and system cooling. In both the alarms above, please take immediate action as shown below.
CPU 1 Temperature/CPU 2 Temperature/System Temperature
This feature displays current temperature readings for the CPUs and the System. The following items will be displayed for your reference only:
CPU 1 Temperature/ CPU 2 Temperature
The CPU Temperature feature will display the CPU temperature status as detected by the BIOS:
Low – This level is considered as the ‘normal’ operating state. The CPU temperature is well below the CPU ‘Temperature Tolerance’. The motherboard fans and CPU will run normally as confi gured in the BIOS (Fan Speed Control).
o
C above the threshold temperature as predefi ned by the CPU
User intervention: No action required. Medium – The processor is running warmer. This is a ‘precautionary’ level and
generally means that there may be factors contributing to this condition, but the CPU is still within its normal operating state and below the CPU ‘Temperature Tolerance’. The motherboard fans and CPU will run normally as confi gured in the BIOS. The fans may adjust to a faster speed depending on the Fan Speed Control settings.
4-17
Page 78
X8DTH-6/X8DTH-6F/X8DTH-i/X8DTH-iF User's Manual
User intervention: No action is required. However, consider checking the CPU fans and the chassis ventilation for blockage.
High – The processor is running hot. This is a ‘caution’ level since the CPU’s ‘Tem­perature Tolerance’ has been reached (or has been exceeded) and may activate an overheat alarm. The system may shut down if it continues for a long period to prevent damage to the CPU.
User intervention: If the system buzzer and Overheat LED has activated, take action immediately by checking the system fans, chassis ventilation and room temperature to correct any problems.
Notes:
1. The CPU thermal technology that reports absolute temperatures (Celsius/ Fahrenheit) has been upgraded to a more advanced feature by Intel in its newer processors. The basic concept is each CPU is embedded by unique temperature information that the motherboard can read. This ‘Temperature Threshold’ or ‘Temperature Tolerance’ has been assigned at the factory and is the baseline on which the motherboard takes action during different CPU temperature conditions (i.e., by increasing CPU Fan speed, triggering the Overheat Alarm, etc). Since CPUs can have different ‘Temperature Tolerances’, the installed CPU can now send information to the motherboard what its ‘Temperature Tolerance’ is, and not the other way around. This results in better CPU thermal management.
Supermicro has leveraged this feature by assigning a temperature status to certain thermal conditions in the processor (Low, Medium and High). This makes it easier for the user to understand the CPU’s temperature status, rather than by just simply seeing a temperature reading (i.e., 25
o
C).
The information provided above is for your reference only. For more information on thermal management, please refer to Intel’s Web site at www.Intel.com.
2. To avoid possible overheating, be sure to provide adequate airfl ow to the system.
System Temperature: The system te mperat ure will b e displayed ( in degre es in Celsiu s and Fahrenh eit) as it is detec ted by the BI OS.
Fan Speed Readings
This feature displays the fan speed readings from Fan1 through Fan8.
Fan Speed Control Modes
This feature allows the user to decide how the system controls the speeds of the onboard fans. The CPU temperature and the fan speed are correlative. When the CPU on-die temperature increases, the fan speed will also increase, and vice versa. Select Workstation if your system is used as a Workstation. Select Server if your system is used as a Server. Select Disabled to disable the fan speed control func-
4-18
Page 79
Chapter 4: AMI BIOS
tion and allow the onboard fans to constantly run at full speed. The Options are:
Full Speed, Server, Workstation/Desktop, and Super Quiet.
Voltage Readings
The following voltage readings will be displayed. CPU1 Vcore, CPU2 Vcore, CPU1 Vtt, CPU2 Vtt, CPU1 DIMM, CPU2 DIMM, 1.1V,
1.5V, 1.8V, 3.3V, 12V, 5V, 3.3 Vsb, and VBAT
ACPI Con guration
Use this feature to confi gure Advanced Confi guration and Power Interface (ACPI) power management settings for your system.
ACPI Aware O/S
Enable ACPI support if it is supported by the OS to control ACPI through the Operat­ing System. Otherwise, disable this feature. The options are Yes and No.
ACPI Version Features
The options are ACPI v1.0, ACPI v2.0 and ACPI v3.0. Please refer to ACPI's website for further explanation: http://www.acpi.info/.
PS2 KB/ MS Wake Up
Select Enable to "wake-up" the system using either the PS2 keyboard or mouse (if equipp ed) when th e system is in S 3 (Sleep) or S4 (H ibern ate) state. The opti ons are Enabl ed and Disabled.
ACPI APIC Support
Select Enabled to include the ACPI APIC Table Pointer in the RSDT (Root System Description Table) pointer list. The options are Enabled and Disabled.
APIC ACPI SCI IRQ
When this item is set to Enabled, APIC ACPI SCI IRQ is supported by the system. The options are Enabled and Disabled.
Headless Mode
This feature is used to enable system to function without a keyboard, monitor and/ or mouse attached The options are Enabled and Disabled.
High Performance Event Timer
Select Enabled to activate the High Performance Event Timer (HPET) that produces periodic interrupts at a much higher frequency than a Real-time Clock (RTC) does in synchronizing multimedia streams, providing smooth playback and reducing the de­pendency on other timestamp calculation devices, such as an x86 RDTSC Instruc-
4-19
Page 80
X8DTH-6/X8DTH-6F/X8DTH-i/X8DTH-iF User's Manual
tion embedded in the CPU. The High Performance Event Timer is used to replace the 8254 Programmable Interval Timer. The options are Enabled and Disabled.
IPMI Con guration
Intelligent Platform Management Interface (IPMI) is a set of common interfaces that IT administrators can use to monitor system health and to manage the system as a whole. For more information on the IPMI specifi cations, please visit Intel's website at www.intel.com.
IPMI Firmware Revision
This item displays the current IPMI fi rmware revision.
Status of BMC
Baseboard Management Controller (BMC) manages the interface between system management software and platform hardware. This is an informational feature which returns the status code of the BMC micro controller.
View BMC System Event Log
This feat ur e d i sp l ays t h e BMC Sys te m Event Lo g (SE L). It shows the total number of entries of BMC System Events. To view an event, select an Entry Number and pressing <Enter> to display the information as shown in the screen.
Total Number of Entries
SEL Entry Number
SEL Record ID
SEL Record Type
Timestamp, Generator ID
Event Message Format User
Event Sensor Type
Event Sensor Number,
Event Dir Type
Event Data.
4-20
Page 81
Chapter 4: AMI BIOS
Clear BMC System Event Log
Select OK and press the <Enter> key to clear the BMC system log. Select Cancel to keep the BMC System log. The options are OK and Cancel.
Caution: Any cleared information is unrecoverable. Make absolutely sure that you no longer need any data stored in the log before clearing the BMC Event Log.
Set LAN Con guration
Set this feature to confi gure the IPMI LAN adapter with a network address as shown in the following graphics.
Channel Number - Enter the channel number for the SET LAN Confi g com- mand. This is initially set to [01]. Press "+" or "-" on your keyboard to change the Channel Number.
Channel Number Status - This feature returns the channel status for the Channel Number selected above: Channel Number is OK" or "Wrong Channel Number".
IP Address Source
Select the source of this machine's IP address. If Static is selected, you will need to know and enter manually the IP address of this machine below . If DHCP is selected, the BIOS will search for a DHCP (Dynamic Host Confi guration Protocol) server in the network it is attached to, and request the next available IP address. The options are DHCP and Static. If DHCP is selected, the following items will display:
IP Address
Enter the IP address for this machine. This should be in decimal and in dotted quad form. The value of each three-digit number separated by dots should not exceed 255 as shown in the screen below.
Subnet Mask
Subnet masks tell the network which subnet this machine belongs to. The value of each three-digit number separated by dots should not exceed 255.
Gateway Address
This is the IP address of the gateway in the network. This is usually a router.
Mac Address
The BIOS will automatically enter the Mac address of this machine; however it may be over-ridden. Mac addresses are 6 two-digit hexadecimal numbers (Base 16, 0 ~ 9, A, B, C, D, E, F) separated by dots. (i.e., 00.30.48.D0.D4.60).
4-21
Page 82
X8DTH-6/X8DTH-6F/X8DTH-i/X8DTH-iF User's Manual
SET PEF Confi guration
PEF Support
Select Enabled to enable the function of Platform Event Filter (PEF) which will interpret BMC events and perform actions based on pre-determined settings or events and performs actions based on pre-determined settings or 'traps' under IPMI 1.5 specifi cations. For example, powering the system down or sending an alert when a triggering event is detected. The default is Disabled. If this item is set to Enabled, the following items will display.
PEF Action Global Control (Available if PEF Support is enabled)
These are the different actions based on BMC events. The options are Alert, Power Down, Reset System, Power Cycle, OEM Action, Diagnostic Interface.
Alert Startup Delay (Available if PEF Support is enabled)
This feature inserts a delay during startup for PEF alerts. The options are Enabled and Disabled. If this item is enabled, the following item will display:
PEF Alert Startup Delay (Available if Alert Startup Delay is enabled)
This feature allows the user to select the delay time setting for PEF Alerts after power-up from S4, S5 or Reset. The options are No Delay, 30 Sec., 60 Sec.,
1.5 Min., and 2.0 Min.
Startup Delay (Available if PEF Support is enabled) Select Enable to enable startup delay support. The options are Enabled and
Disabled.
PEF Startup Delay (Available if Startup Delay is enabled)
This feature allows the user to select the delay time setting after PEF startup. The options are No Delay, 30 Sec., 60 Sec., 1.5 Min., and 2.0 Min.
Event Message for PEF Action (Available if PEF Support is enabled) Select Enable to enable Event Messages for PEF action. Refer to Table 24.6 of
the IPMI 1.5 Specifi cation for more information at www.intel.com. The options are Disabled and Enabled.
BMC Watch Dog Timer Action
This feature Allows the BMC to reset or power down the system if the OS hangs or crashes. The options are Disabled, Reset System, Power Down, Power Cycle.
BMC Watch Dog TimeOut [Min:Sec]
This is a timed delay in minutes or seconds before a power down or system reset due to an OS failure. The options are [5 Min], [1 Min], [30 Sec], and [10 Sec].
4-22
Page 83
Chapter 4: AMI BIOS
Event Log Confi guration
View Event Log
Use this option to view the System Event Log.
Mark all events as read
This option marks all events as read. The options are OK and Cancel.
Clear event log
This option clears the Event Log memory of all messages. The options are OK and Cancel.
PCI Error Log Use this option to enable PCI error (PERR) logging. The options are Yes and No.
4-4 Security Settings
The AMI BIOS provides a Supervisor and a User password. If you use both pass­words, the Supervisor password must be set fi rst.
Supervisor Password
This item indicates if a Supervisor password has been entered for the system. "Not Installed" means a Supervisor password has not been used.
User Password
This item indicates if a user password has been entered for the system. "Not I n­stalle d" means that a u ser password has not been used.
4-23
Page 84
X8DTH-6/X8DTH-6F/X8DTH-i/X8DTH-iF User's Manual
Change Supervisor Password
Select this feature and press <Enter> to access the submenu, and then type in a new Supervisor Password.
User Access Level (Available when Supervisor Password is set as above)
The Options are Full Access, View Only, Limited, and No Access
Full Access
: This feature grants full User read and write access to the Setup
Utility.
View Only: This feature allows the user to access the Setup Utility, but the user
is not allowed to change settings.
Limited: This feature allows only limited fi elds to be changed by the user.
No Access: This feature prevents User from accessing the Setup Utility.
Change User Password
Select this feature and press <Enter> to access the submenu , and then type in a new User Password.
Clear User Password (Available only when User Password has been set) This item allows you to clear a user password after it has been entered.
Password Check
This item allows you to check a password after it has been entered. The options are Setup and Always.
Boot Sector Virus Protection
When Enabled, the AMI BIOS displays a warning when any program (or virus) is­sues a Disk Format command or attempts to write to the boot sector of the hard disk drive. The options are Enabled and Disabled.
4-5 Boot Confi guration
Use this feature to confi gure boot settings.
4-24
Page 85
Boot Device Priority
Chapter 4: AMI BIOS
This feature allows the user to specify the sequence of priority for the Boot Device. The settings are 1st boot device, 2nd boot device, 3rd boot device, 4th boot device, 5th boot device and Disabled.
1st Boot Device - [USB: XXXXXXXXX]
2nd Boot Device - [CD/DVD: XXXXXXXXX]
Hard Disk Drives
This feature allows the user to specify the boot sequence from all available hard disk drives. The settings are Disabled and a list of all hard disk drives that have been detected (i.e., 1st Drive, 2nd Drive, 3rd Drive, etc).
1st Drive - [SATA: XXXXXXXXX]
Removable Drives
This feature allows the user to specify the boot sequence from available Removable Drives. The settings are 1st boot device, 2nd boot device, and Disabled.
1st Drive - [USB: XXXXXXXXX]
2nd Drive
4-25
Page 86
X8DTH-6/X8DTH-6F/X8DTH-i/X8DTH-iF User's Manual
CD/DVD Drives
This feature allows the user to specify the boot sequence from available CD/DVD Drives (i.e., 1st Drive, 2nd Drive, etc).
4-6 Exit Options
Select the Exit tab from the AMI BIOS Setup Utility screen to enter the Exit BIOS Setup screen.
Save Changes and Exit
When you have completed the system confi guration changes, select this option to leave the BIOS Setup Utility and reboot the computer, so the new system con­ guration parameters can take effect. Select Save Changes and Exit from the Exit menu and press <Enter>.
Discard Changes and Exit
Select this option to quit the BIOS Setup without making any permanent changes to the system confi guration, and reboot the computer. Select Discard Changes and Exit from the Exit menu and press <Enter>.
Discard Changes
Select this option and press <Enter> to discard all the changes and return to the AMI BIOS Utility Program.
Load Optimal Defaults
To set this feature, select Load Optimal Defaults from the Exit menu and press <Enter>. Then, select OK to allow the AMI BIOS to automatically load Optimal De-
4-26
Page 87
Chapter 4: AMI BIOS
faults to the BIOS Settings. The Optimal settings are designed for maximum system performance, but may not work best for all computer applications.
Load Fail-Safe Defaults
To set this feature, select Load Fail-Safe Defaults from the Exit menu and press <Enter>. The Fail-Safe settings are designed for maximum system stability, but not for maximum performance.
4-27
Page 88
X8DTH-6/X8DTH-6F/X8DTH-i/X8DTH-iF User's Manual
4-7 BIOS Recovery
Warning! Do not upgrade the BIOS unless your system has a BIOS-related
issue. Flashing the wrong BIOS can cause irreparable damage to the system. In no event shall Supermicro be liable for direct, indirect, special, incidental, or consequential damages arising from a BIOS update. If you need to update the BIOS, do not shut down or reset the system while the BIOS is updating. This is to avoid possible boot failure.
How to Recover the AMIBIOS Image (Main BIOS Block)
An AMIBIOS fl ash chip consists of a boot sector block, and a main BIOS code block (a main BIOS image). The boot sector block contains critical BIOS code, including memory detection and recovery code to be used to fl ash a new BIOS image if the original BIOS Image is corrupted. When the system is powered on, the boot sector code executes fi rst. Once it is completed, the main BIOS code will continue with system initialization and complete the bootup process.
Notes: BIOS Recovery described below is used when the main BIOS block crashes. However, when the BIOS Boot sector crashes, you will need to send the motherboard back to Supermicro for RMA repairs.
4.7.1 Boot Sector Recovery from a USB Device
This feature allows the user to recover a BIOS image using a USB device without additional utilities needed. A user can download the BIOS image into a USB fl ash device, and name the fi le "SUPER.ROM" for the recovery process to load the fi le. A USB fl ash device such as a USB Flash Drive, a USB CDROM or a USB CDRW device can be used for this purpose,
Insert the USB device that contains the new BIOS image (the ROM fi les) 1. saved in a root directory into your USB drive.
While turning the power on, press and hold <Ctrl> and <Home> at the same 2. time until the USB Access LED Indicator comes on. This might take a few seconds.
Once the USB drive LED is on, release the <Ctrl> and <Home> keys. 3. AMIBIOS will issue beep codes to indicate that the BIOS ROM fi le is being updated.
When BIOS fl ashing is completed, the computer will reboot. Do not interrupt 4. the fl ashing process until it is completed.
4-28
Page 89
Chapter 4: AMI BIOS
4.7.2 Boot Sector Recovery from an IDE CD-ROM
This process is almost identical to the process of Boot Sector Recovery from a USB device, except that the BIOS image fi le is loaded from a CD-ROM. Use a CD-R or CD-RW drive to burn a CD with the BIOS image fi le in it, and name the fi le "SUPER. ROM" for the recovery process to load the fi le.
4.7.3 Boot Sector Recovery from a Serial Port ("Serial Flash")
This process, also known as "Serial Flash," allows the user to use a serial port to load a BIOS image for Boot Sector recovery . This feature is usually used for embed­ded systems that rely on a serial port for remote access and debugging.
Requirements
In order to use Serial Flash for Boot Sector Recovery, you will need to meet the following requirements.
The "Target system," the system that needs BIOS updates, must have a serial
port and "Serial Flash" support embedded in the BIOS image fi le. The "Host system" should also have a serial port and a terminal program that
supports XModem Transfer protocol (Hyper Terminal for the Windows operating systems, and minicom for Linux/FreeSBD, etc.).
A Null_modem serial cable
How to use Serial Flash for Boot Sector Recovery
Connect a Null_modem serial cable between the target system and the host 1. system that runs the terminal program.
Make sure that the new BIOS Image fi le is accessible for the host system.2.
Start the terminal program on the host system and create a new connection. 3. Use the following communication parameters for the new connection.
Bits per second: 115200 bits/sec.
Data Bits: 8 Parity: None Stop Bit: 1 Flow Control: None
4-29
Page 90
X8DTH-6/X8DTH-6F/X8DTH-i/X8DTH-iF User's Manual
4. Power on your system and click the <Connect> button in the Hyper Terminal. The terminal screen will display the following messages.
Press <SpaceBar> to update BIOS. Confirm update BIOS? (y/n) y Begin remote BIOS flash? (y/n) y Starting remote flash. Upload new BIOS file using Xmodem protocol.
5. Following the instructions given on the screen to update the BIOS. These instructions are also shown below.
a. At the prompt, press the <SpaceBar> to update the BIOS. b. When asked to confi rm BIOS updating, press <y> to confi rm BIOS
updates.
c. Press <y> again to begin fl ashing BIOS remotely.
Note: Be sure to complete Steps a~c above quickly because you have a second or less to do so.
6. Once you've completed the instructions given, a screen will display to indicate that remote fl ashing is starting and the new BIOS fi le is being uploaded.
7. To use Hyper Terminal to transfer the XModem protocol by using the "Send File" dialog under the "Transfer" menu, follow the instructions below to com­plete XModem transfers.
a. Select the "Transfer" menu and enter <Send>.
b. Specify the location of the ROM fi le and select the proper protocol (XMo-
dem).
c. Press <Send> to start ROM File extraction. (See the picture below.)
4-30
Page 91
Chapter 4: AMI BIOS
d. Once the ROM fi le extraction is completed, the message: "New BIOS re-
ceived OK" will display.
8. Once remote BIOS fl ash is completed, the system will reboot.
Note: AMIBIOS Serial Flash will work with any terminal communications program that supports VT-100 and XModem protocols, including protocols designed for GNU/LINUX & BSD operating systems such as minicom. It is recommended that the terminal program be confi gured to use the 'CR/ LF' style of line termination.
4-31
Page 92
X8DTH-6/X8DTH-6F/X8DTH-i/X8DTH-iF User's Manual
Notes
4-32
Page 93
Appendix A: BIOS POST Error Codes
Appendix A
BIOS Error Beep Codes
During the POST (Power-On Self-Test) routines, which are performed each time the system is powered on, errors may occur.
Non-fatal errors are those which, in most cases, allow the system to continue with the boot-up process. The error messages normally appear on the screen.
Fatal errors are those which will not allow the system to proceed with the boot-up procedure. If a fatal error occurs, you should consult with your system manufacturer for possible repairs.
These fatal errors are usually communicated through a series of audible beeps.
BIOS Error Beep Codes
Beep Code Error Message Description
1 beep Refresh Circuits have been reset.
(Ready to power up)
5 short beeps, 1 long beep
8 beeps Display memory
1 continuous beep w/ Front Panel OH LED on
Memory error No memory detected in the
system Video adapter missing or with
read/write error System Overheat 1 continuous beep with the
faulty memory
front panel OH LED on
A-1
Page 94
X8DTH-6/X8DTH-6F/X8DTH-i/X8DTH-iF User's Manual
Notes
A-2
Page 95
Appendix B: Installing the Windows OS
Appendix B
Installing the Windows OS
After all hardware components have been installed, you must fi rst confi gure Intel South Bridge RAID Settings before you install the Windows OS and other software drivers. T o confi gure RAID settings, please refer to RAID Confi guration User Guides posted on our website at www.supermicro.com/support/manuals.
B-1 Installing the Windows OS to a RAID System
Insert Microsoft's Windows XP/2003/2008/Vista Setup CD in the CD Driver, 1. and the system will start booting up from CD.
Press the <F6> key when the message-" Press F6 if you need to install a 2. third party SCSI or RAID driver" displays.
When the Windows XP/2003/2008/Vista Setup screen appears, press "S" to 3. specify additional device(s).
Insert the driver diskette-"Intel AA RAID XP/2003/2008/Vista Driver for 4. ICH10R" into Drive A: and press the <Enter> key.
Choose the Intel(R) ICH10R 5. SATA RAID Controller from the list indicated in the Windows OS Setup Screen, and press the <Enter> key.
Press the <Enter> key to continue the installation process. (If you need to 6. specify any additional devices to be installed, do it at this time.) Once all devices are specifi ed, press the <Enter> key to continue with the installation.
From the Windows OS Setup screen, press the <Enter> key. The Windows 7. OS Setup will automatically load all device fi les and then, continue the Win- dows OS installation.
After the Windows OS Installation is completed, the system will automatically 8. reboot.
B-1
Page 96
X8DTH-6/X8DTH-6F/X8DTH-i/X8DTH-iF User's Manual
B-2 Installing the Windows OS to a Non-RAID System
Insert Microsoft's Windows XP/Windows 2003/Windows 2008/Windows Vista 1. Setup CD in the CD Driver, and the system will start booting up from CD.
Continue with the OS installation. The Windows OS Setup screen will display.2.
From the Windows OS Setup screen, press the <Enter> key. The Windows 3. OS Setup will automatically load all device fi les and then continue with the Windows OS installation.
After the Windows OS Installation is completed, the system will automatically 4. reboot.
Insert the Supermicro Setup CD that came with your motherboard into the CD 5. Drive during system boot, and the main screen will display.
B-2
Page 97
Appendix C: Software Installation Instructions
Appendix C
Software Installation Instructions
C-1 Installing Software Programs
After you've installed the Windows Operating System, a screen as shown below will appear. You are ready to install software programs and drivers that have not yet been installed. To install these software programs and drivers, click the icons to the right of these items.
Notes:
1. Click the icons showing a hand writing on the paper to view the readme les for each item. Click on a computer icon to the right of an item to install an item (from top to the bottom) one at a time. After installing each item, you must re-boot the system before proceeding with the next item on the list. The bottom icon with a CD on it allows you to view the entire contents of the CD.
2. When making a storage driver diskette from booting into a Driver CD, please set the SATA Confi guration to "Compatible Mode" and confi gure SATA as IDE in the BIOS Setup. After making the driver diskette, be sure to change the SATA settings back to your original settings.
Driver/Tool Installation Display Screen
C-1
Page 98
X8DTH-6/X8DTH-6F/X8DTH-i/X8DTH-iF User's Manual
C-2 Confi guring Supero Doctor III
The Supero Doctor III program is a Web-base management tool that supports remote management capability. It includes Remote and Local Management tools. The local management is called the SD III Client. The Supero Doctor III program included on the CDROM that came with your motherboard allows you to monitor the environment and operations of your system. Supero Doctor III displays crucial system information such as CPU temperature, system voltages and fan status. See the Figure below for a display of the Supero Doctor III interface.
Note: 1 The default user name and password are ADMIN. Note 2: In the Windows OS environment, the Supero Doctor III settings
take precedence over the BIOS settings. When fi rst installed, Supero Doc- tor III adopts the temperature threshold settings previously set in BIOS. Any subsequent changes to these thresholds must be made within Supero Doc­tor, since the SD III settings override the BIOS settings. For the Windows OS to adopt the BIOS temperature threshold settings, please change the SDIII settings to be the same as those set in BIOS.
Supero Doctor III Interface Display Screen-I (Health Information)
C-2
Page 99
Appendix C: Software Installation Instructions
Supero Doctor III Interface Display Screen-II (Remote Control)
Note: SD III Sof tware Revisio n 1. 0 can be downloa ded from our Web -
site at: f tp://ft p.superm icro.co m/utilit y/Supero _D octor_I II/. You c an also download SDIII User's Guide at: http://www.supermicro.com/PRODUCT/ Manuals/SDIII/UserGuide.pdf. For Linux, we will still recommend that you use Supero Doctor II.
C-3
Page 100
X8DTH-6/X8DTH-6F/X8DTH-i/X8DTH-iF User's Manual
Notes
C-4
Loading...