The information in this User’s Manual has been carefully reviewed and is believed to be accurate.
The vendor assumes no responsibility for any inaccuracies that may be contained in this document,
makes no commitment to update or to keep current the information in this manual, or to notify any
person or organization of the updates. Please Note: For the most up-to-date version of this
manual, please see our web site at www.supermicro.com.
Super Micro Computer, Inc. ("Supermicro") reserves the right to make changes to the product
described in this manual at any time and without notice. This product, including software and documentation, is the property of Supermicro and/or its licensors, and is supplied only under a license.
Any use or reproduction of this product is not allowed, except as expressly permitted by the terms
of said license.
IN NO EVENT WILL SUPERMICRO BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL,
SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO
USE THIS PRODUCT OR DOCUMENTATION, EVEN IF ADVISED OF THE POSSIBILITY OF
SUCH DAMAGES. IN PARTICULAR, SUPERMICRO SHALL NOT HAVE LIABILITY FOR ANY
HARDWARE, SOFTW ARE, OR DA TA STORED OR USED WITH THE PRODUCT, INCLUDING THE
COSTS OF REPAIRING, REPLACING, INTEGRATING, INSTALLING OR RECOVERING SUCH
HARDWARE, SOFTWARE, OR DATA.
Any disputes arising between manufacturer and customer shall be governed by the laws of Santa
Clara County in the State of California, USA. The State of California, County of Santa Clara shall
be the exclusive venue for the resolution of any such disputes. Super Micro's total liability for all
claims will not exceed the price paid for the hardware product.
FCC Statement: This equipment has been tested and found to comply with the limits for a Class
A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the manufacturer’s instruction manual, may cause harmful
interference with radio communications. Operation of this equipment in a residential area is likely
to cause harmful interference, in which case you will be required to correct the interference at your
own expense.
California Best Management Practices Regulations for Perchlorate Materials: This Perchlorate
warning applies only to products containing CR (Manganese Dioxide) Lithium coin cells. “Perchlorate
Material-special handling may apply. See www.dtsc.ca.gov/hazardouswaste/perchlorate”
WARNING: Handling of lead solder materials used in this
product may expose you to lead, a chemical known to
the State of California to cause birth defects and other
reproductive harm.
Manual Revision: Rev. 1.0a
Release Date: March 28, 2010
Unless you request and receive written permission from Super Micro Computer, Inc., you may not
copy any part of this document.
Information in this document is subject to change without notice. Other products and companies
referred to herein are trademarks or registered trademarks of their respective companies or mark
holders.
This manual is written for system integrators, PC technicians and knowledgeable PC
users. It provides information for the installation and use of the X8DTGQF motherboard.
About This Motherboard
The X8DTG-QF motherboard supports the Intel 5500/5600 Series Processor platform and the QuickPath Interconnect (QPI) Technology, providing the next
generation point-to-point system interface that replaces the current Front Side Bus.
With the 5500/5600 Series Processor and dual Intel 5520 IOH-36D chips built in, the
X8DTG-QF substantially enhances system performance with increased bandwidth
and unprecedented scalability optimized for HPC/Cluster and high-end 4U servers.
Please refer to our web site (http://www.supermicro.com/products/) for updates on
supported processors. This product is intended to be installed and serviced by
professional technicians.
Preface
Manual Organization
Chapter 1 describes the features, specifi cations and performance of the mother-
board and provides detailed information about the chipset.
Chapter 2 provides hardware installation instructions. Read this chapter when in-
stalling the processor, memory modules and other hardware components into the
system. If you encounter any problems, see Chapter 3, which describes troubleshooting procedures for video, memory and system setup stored in the CMOS.
Chapter 4 includes an introduction to BIOS and provides detailed information on
running the CMOS Setup utility.
Appendix A lists BIOS POST Error Codes. Appendix B and Appendix C provide
the Windows OS and Other Software Installation Instructions.
Conventions Used in the Manual
Special attention should be given to the following symbols for proper installation
and to prevent product damage or bodily injury.
iii
Page 4
X8DTG-QF User's Manual
Warning: Important information given to ensure proper system installation
or to prevent damage to the components.
Note: Additional Information given to differentiate various models or to
ensure correct system setup.
C-2 Confi guring Supero Doctor III ......................................................................... C-2
viii
Page 9
Chapter 1: Introduction
Chapter 1
Introduction
1-1 Overview
Checklist
Congratulations on purchasing your computer motherboard from an acknowledged
leader in the industry. Supermicro boards are designed with the utmost attention to
detail to provide you with the highest standards in quality and performance. Check
that the following items have all been included with your motherboard. If anything
listed here is damaged or missing, contact your retailer.
The following items are included in the retail package.
One (1) Supermicro Mainboard
•
Six (6) Serial ATA cables (CBL-0044L) •
One (1) I/O backpanel shield (MCP-260-00025-0N) •
One (1) Supermicro CD containing drivers and utilities•
1-1
Page 10
X8DTG-QF User's Manual
X8DTG-QF Motherboard Image
Note: The drawings and pictures shown in this manual were based on the
latest PCB Revision available at the time of publishing of the manual. The
motherboard you’ve received may or may not look exactly the same as
the graphics shown in the manual.
1-2
Page 11
Chapter 1: Introduction
X8DTG-QF Motherboard Layout
KB/MOUSE
VGA
USB0/1
USB2/3/4/5
LAN2
J138
CD1
Audio CTRL
ALC888
JL2
IPMI
Firmware
1
D33
FAN5
FAN6
COM1
LAN1
AUDIO FP
CD-IN
LAN CTRL
JAUDIO1
LAN CTRL
JPAC
WPCM450
BMC CTRL
Memory
for IPMI
COM2
JPUSB1
IPMI_LAN
PHY
82574
82574
JPL2
JPL1
JI2C2
JI2C1
JPG1
CPU
VRM
FAN8/CPU2
Slot11 PCI-E 2.0 x4(in x8 Slot)
Slot10 PCI-E 2.0 x16
Slot8 PCI-E 2.0 x16
Slot6 PCI-E 2.0 x16
Slot5 PCI 33MHz
Slot4 PCI-E 2.0 x16
Slot3 PCI 33MHz
Slot2 PCI-E 2.0 x4(in x16 Slot)
Slot1 PCI-E x4(in x16 Slot)
P2-DIMM3A
P2-DIMM3B
P2-DIMM2A
P2-DIMM2B
P2-DIMM1A
P2-DIMM1B
ALWAYS POPULATE DIMM A FIRST
CPU2
X8DTG-QF
Rev. 2.0
JP3
1
JP6
J18
JSMB1
JWOL
JWD
Intel 5520
IOH-36D
TPM
Intel
ICH 10R
PWR I2C
FAN7/CPU1
JPI2C
JBT1
JPW2
ALWAYS POPULATE DIMM A FIRST
FAN9
BIOS
T-SGPIO1
JTPM1
P1-DIMM1B
P1-DIMM1A
P1-DIMM2B
P1-DIMM2A
P1-DIMM3B
P1-DIMM3A
Intel 5520
IOH-36D
CPU1
T-SGPIO2
JPW1
JPW3
FAN1
FAN2
JD1
FAN3
FAN10
SP1
DP1
FP CTRL
JF1
JOH1
USB7
Battery
I-SATA4
I-SATA5
I-SATA3
USB6
JPUSB2
USB8/9
FAN4
JL1
I-SATA0
I-SATA2
I-SATA1
Notes:
Jumpers not indicated are for test purposes only. For more information on 1.
jumpers or components, refer to Chapter 2.
" " indicates the location of Pin 1.2.
When DP1 LED is on, the onboard power connection is on. Make sure to 3.
unplug the power cables before removing or installing components.
1-3
Page 12
X8DTG-QF User's Manual
X8DTG-QF Quick Reference
KB/MOUSE
VGA
USB0/1
USB2/3/4/5
LAN2
J138
CD1
Audio CTRL
ALC888
JL2
IPMI
Firmware
1
D33
FAN5
FAN6
COM1
LAN1
AUDIO FP
CD-IN
LAN CTRL
JAUDIO1
LAN CTRL
JPAC
WPCM450
BMC CTRL
Memory
for IPMI
COM2
JPUSB1
IPMI_LAN
PHY
82574
82574
JPL2
JPL1
JI2C2
JI2C1
JPG1
FAN8/CPU2
CPU
VRM
Slot11 PCI-E 2.0 x4(in x8 Slot)
Slot10 PCI-E 2.0 x16
Slot8 PCI-E 2.0 x16
Slot6 PCI-E 2.0 x16
Slot5 PCI 33MHz
Slot4 PCI-E 2.0 x16
Slot3 PCI 33MHz
Slot2 PCI-E 2.0 x4(in x16 Slot)
Slot1 PCI-E x4(in x16 Slot)
P2-DIMM3A
P2-DIMM3B
P2-DIMM2A
P2-DIMM2B
P2-DIMM1A
P2-DIMM1B
ALWAYS POPULATE DIMM A FIRST
CPU2
X8DTG-QF
Rev. 2.0
JP3
1
JP6
J18
JSMB1
JWOL
JWD
Intel 5520
IOH-36D
TPM
Intel
ICH 10R
PWR I2C
FAN7/CPU1
JPI2C
JBT1
JPW2
ALWAYS POPULATE DIMM A FIRST
FAN9
BIOS
T-SGPIO1
JTPM1
P1-DIMM1B
P1-DIMM1A
P1-DIMM2B
P1-DIMM2A
P1-DIMM3B
P1-DIMM3A
Intel 5520
IOH-36D
CPU1
T-SGPIO2
JPW1
JPW3
FAN1
FAN2
JD1
FAN3
FAN1 0
SP1
DP1
FP CTRL
JF1
JOH1
USB7
Battery
I-SATA4
I-SATA5
I-SATA3
USB6
JPUSB2
USB8/9
FAN4
JL1
I-SATA0
I-SATA2
I-SATA1
Warning: To avoid possible system overheating, please be sure to provide
adequate airfl ow to your system.
1-4
Page 13
Chapter 1: Introduction
X8DTG-QF Quick Reference (See Chapter 2 for Details)
(HD) Audio/CD-In/FP Audio7.1 Channel High Defi nition Audio (JAUDIO1)/
CD-In (CD-1)/Front Panel Audio
COM1/COM2COM1/COM2 Serial Connections
FAN#1~10System/CPU Fan Headers (Fans 7~8: CPU Fans)
I-SATA0 ~ 5(Intel South Bridge) SATA Ports 0~5
JD1PWR LED (Pins 1~3)/Speaker (Pins 4~7)
JF1Front Panel Connector
JL1Chassis Intrusion
JOH1Overheat LED Indicator
JPW1,JPW2/JPW312V 24-pin Main PWR, 8-pin PWR Connectors
JSMB1System Management Bus I
2
C Header
JTPM1TPM (Trusted Platform Module) Header
JWOLWake-On_LAN
KB/MousePS2 Keyboard/Mouse
LAN1/2, IPMI_LANGigabit Ethernet Ports 1~2, IPMI LAN
SP1Internal Speaker/Buzzer Header
T-SGPIO-0/1Serial General Purpose IO Headers
USB 0/1, 2/3/4/5Backplane USB Ports 0/1, 2/3/4/5
USB 6, 7, 8/9Front Panel USB 6, 7, 8/9
VGAVideo Port
LEDDescription
DP1O nboar d Stan dby PWR war ning LED I ndic ator
D33BMC LED Indicator
1-5
Page 14
X8DTG-QF User's Manual
Motherboard Features
CPU
Two Intel•
porting two full-width Intel QuickPath Interconnect (QPI) links with a total of up
to 51.2 GT/s Data Transfer Rate (6.4 GT/s per direction)
®
5500/5600 Series (LGA 1366) processors with each processor sup-
Memory
Twelve 240-pin DIMM sockets support up to 192* GB of Registered ECC or up •
to 48 GB of Unbuffered ECC/Non-ECC DDR3 1333/1066/800 MHz Memory . (For
Unbuffered ECC/Non-ECC memory, maximum of 4 GB per DIMM is supported.
See Section 2-4 in Chapter 2 for memory Population.) (*Refer to our memory
recommendation list posted on our website at www.supermicro.com.)
Chipset
Dual Intel 5520 chip platforms, including: dual 5520 (IOH-36D) chips and the •
ICH10R (South Bridge).
Expansion Slots
Four PCI-E Gen. 2.0 x16 slots (Slot 4, Slot 6, Slot 8, Slot 10)•
One PCI-E Gen. 1.0 x4 (in x16) slot (Slot 1)•
One PCI-E Gen. 2.0 x4 (in x16) slot (Slot 2)•
One PCI-E Gen. 2.0 x4 (in x8) slot (Slot 11)•
Two PCI 33 MHz slots (Slot 3, Slot 5)•
BIOS
4 GB AMI SPI Flash ROM•
ACPI 1.0/2.0/3.0, Plug and Play (PnP), DMI 2.3, SMBIOS 2.3, RTC (Real Time-•
Clock) Wake-up, PCI 2.2, Hardware BIOS Virus protection, and USB Keyboard
support
PC Health Monitoring
Onboard voltage monitors for CPU1 VCore, CPU2 VCore, +5Vin, • 12Vcc (V),
VP1 DIMM, VP2 DIMM, +3.3Vcc (V), and Battery Voltage
Fan status monitor with fi rmware control
•
CPU/chass is temper ature moni tors•
Platfo rm Enviro nment Co ntrol Inte rf ace (PECI) read y•
CPU fan auto - of f in sle ep mode•
CPU slow- dow n on tempe rature over heat•
Pulse Wi dth Mo dulati on (PW M) Fan Contro l•
CPU ther mal tr ip supp or t for pro ces sor pr otecti on, power L ED•
Power-up mod e cont rol for r ecover y fr om AC power l oss•
1-6
Page 15
Chapter 1: Introduction
Auto- switc hing vol tage r egulato r for CPU c ore s•
System over heat /Fan Fail LED I ndic ator and c ontr ol•
System re sourc e aler t vi a Super o Doc tor III•
ACPI Features
Slow blinking LED for suspend state indicator•
Main switch override mechanism•
ACPI Pow er Ma nag eme nt•
Keyboard Wakeup from Soft-off •
Onboard I/O
Intel ICH10R supports six SA T A ports (RAID0, RAID1, RAID10, RAID5 supported •
in the Windows OS Environment and RAID 0, RAID 1, RAID 10 supported by
the Linux OS)
2.0 with K V M supp or t
Dual Intel 8 2574 Dual- L A N G iga bit Eth er net Co ntr olle rs s uppo r t du al Gi ga - bit
•
LAN ports
Onboar d PHY Chip su ppor ts IP MI dedic ated L AN
•
Two seri al por t c onnec tio ns (One rear p or t and on e front C OM hea der)•
Up to ten USB 2.0 (Unive rsal Se rial Bus) con necti ons (six rear USB ports, two •
front he ader s, and t wo Type A connec tion s)
VGA por t suppo rte d by the Win bond WP CM4 50 Co ntroll er
•
High Defi nition Audio sup por ted by the A LC88 8 Contr oller•
Super I/ O: Winbo nd W83 527HG •
Other
Console redirection•
Onboa rd Fan Spee d Contr ol by Ther mal Ma nagem ent via BI OS•
CD/Diskette Utilities
BIOS fl ash upgrade utility and device drivers•
Dimensions
Propr ietar y 13.00 " (L) x 15.20 " (W ) (330. 20 mm x 3 86.0 8 mm)•
1-7
Page 16
X8DTG-QF User's Manual
Slot2
PCI-E 2.0
Slot4
PCI-E 2.0
Slot6
PCI-E 2.0
LAN1
LAN2
#0-2
#0-1
DDR3
PCI-E x4
x16
PCI-Ex16
x16
PCI-Ex16
x16
#0-6
#0-5
#0-4
#0-3
800/1066/1333
Ports 1,2
Ports 7,8,9,10
Ports 3,4,5,6
Slot1
PCI-E 1.0
x16
Intel
82574L
Intel
82574L
ALC888
AUDIO
CONN
BIOS
QPI
PCI-E x4
PCI-E x1
PCI-E x1
HD
SPI
PCI Slot3
DDR
Processor1
CSI1
Intel
5520
IOH 36D
Ports 1, 2, 3, 4
Port5
Port6
PCI 33MHZ
PCI Slot5
CSI0
ESI
ESI x4
ESI
QPI
Processor2
QPI
ICH10R
USB
WPCM450
BMC
CSI1
QPI
CSI0
Intel
5520
IOH 36D
LPC BUS
#1-3
#1-2
#1-1
DDR3
800/1066/1333
Ports 1,2
Ports 7,8,9,10
Ports 3,4,5,6
#1
#0
SATA2
#1
#0
USB2.0
SIO
W82527HG
#1-4
#4
#3
#2
SATA2
#3
#2
USB2.0
#1-5
#4
#1-6
PCI-E x4
PCI-E x16
PCI-E x16
#5
#0~#5
#9
#8
#7
#6
#5
#0~#9
SLB9635TT
Slot11
PCI-E 2.0
x8
Slot8
PCI-E 2.0
x16
Slot10
PCI-E 2.0
x16
6 FRONT
+ 2 Type A
6 REAR+2 Internal
TPM
Note: This is a general block diagram. Please see the previous Motherboard Features pages for details on the features of each motherboard.
VGA1
COM1
External
COM2
External/SOL
System Block Diagram
1-8
Third LAN
RTL8201N
Mouse
Keyboard
IPMI
LAN
Page 17
Chapter 1: Introduction
1-2 System Overview
Built upo n the func tional ity and t he capab ility of t he Intel 55 00/5 60 0 Serie s Process or s an d Intel 5 52 0 ch ips et, t he X8 DTG - Q F mo the r boa rd p rovi de s th e perfo rmance an d feature set requir ed for dual- processo r-base d 4U servers opt imized
for High Performance Computing (HPC)/Cluster platforms. The Intel 5520 platform
consists of the 5500/5600 Series (LGA 1366) processor, the 5520 (IOH-36D), and
the ICH10R (South B ridge). With th e I nte l Q u i c k Pat h i nte rconnect (QPI) contr o l le r
built in, t he 550 0/5 600 S eries P roces sor is th e fi rst dual-proc essor plat form th at
offers the next generation point-to-point system interconnect, replacing the current
Front Side Bus T echnology, substantially enhancing system performance by utilizing ser ial link inte rcon nect ions wi th incr eased ba ndwid th and sc alabi lity.
The IOH connects to each processor through an independent QPI (QuickPath
interconnect) link. Each link consists of 20 pairs of unidirectional differential lanes
for tra nsmis sio n and re cei ving i n addit ion t o a dif fer entia l for wa rded c lo ck. A f ull width Q PI link pair p rovide s 84 si gnals. Ea ch proc ess or suppo rt s two Q uickPat h
links, one g oing to th e other pr oce ssor, and the oth er to the 5 520 chip s.
The 552 0 chip set supp or ts PC I Exp ress G en2 la nes pe er-to -pe er read a nd wr ite
transactions. The ICH10R provides multiple PCI-Express SATA and USB connections.
In additi on, the 5 520 plat for m also of fers a w ide ran ge of R AS (Relia bilit y, Availability and Serviceability) features. These features include memory interface ECC,
x4/x8 S ingle Devic e Data C orrec tion (SDD C), Cyclic Redund ancy Chec k (CRC),
parity protection, out-of-band register access via SMBus, memory mirroring,
memor y spa ring, a nd Hot- plug su ppor t on t he PCI -E xpre ss Inter f ace.
Main Features of the 5500/5600 Series Processor and the
5520 Chipset
Four processor cores in each processor with 8MB shared cache among cores•
Two full-width Intel QuickPath interconnect links, up to 6.4 GT/s of data transfer •
rate in each direction
Point-to-point cache coherent interconnect, Fast/narrow unidirectional links, and •
Concurrent bi-directional traffi c
1-9
Page 18
X8DTG-QF User's Manual
1-3 Special Features
Recovery from AC Power Loss
BIOS provides a setting for you to determine how the system will respond when AC
power is lost and then restored to the system. You can choose for the system to
remain powered off (in which case you must press the power switch to turn it back
on) or for it to automatically return to a power- on state. See the Advanced BIOS
Setup section to change this setting. The default setting is Last State.
1-4 PC Health Monitoring
This section describes the PC health monitoring features of the X8DTG-QF. All have
an onboard System Hardware Monitor chip that supports PC health monitoring.
An onboard voltage monitor will scan these onboard voltages continuously: CPU1
VCore, CPU2 VCore, +5Vin, 12Vcc (V), VP1 DIMM, VP2 DIMM, +3.3Vcc (V), and
Battery Voltage. Once a voltage becomes unstable, a warning is given or an error
message is sent to the screen. Users can adjust the voltage thresholds to defi ne
the sensitivity of the voltage monitor.
Fan Status Monitor with Firmware Control
The PC health monitor can check the RPM status of the cooling fans. The onboard
CPU and chassis fans are controlled by Thermal Management via BIOS (under
Hardware Monitoring in the Advanced Setting).
Environmental Temperature Control
The thermal control sensor monitors the CPU temperature in real time and will turn
on the thermal control fan whenever the CPU temperature exceeds a user-defi ned
threshold. The overheat circuitry runs independently from the CPU. Once it detects
that the CPU temperature is too high, it will automatically turn on the thermal fan
control to prevent any overheat damage to the CPU. The onboard chassis thermal
circuitry can monitor the overall system temperature and alert users when the chassis temperature is too high.
To avoid possible system overheating, please be sure to provide adequate
airfl ow to your system.
System Resource Alert
This feature is available when used with Supero D octor III in the Windows OS
environment or used with Supero Doctor II in Linux. Supero Doctor is used to
notif y the user of cer tain system events. For example, you can also confi gure
1-10
Page 19
Chapter 1: Introduction
Supero Doctor to provide you with warnings when the system temperature, CPU
temperat ures, volt ages a nd fan spe eds go beyon d a pre- defi ned range.
1-5 ACPI Features
ACPI stands for Advanced Confi guration and Power Interface. The ACPI specifi ca-
tion defi nes a fl exible and abstract hardware interface that provides a standard
way to integrate power management features throughout a PC system, including
its hardware, operating system and application software. This enables the system
to automatically turn on and off peripherals such as CD-ROMs, network cards, hard
disk drives and printers.
In addition to enabling operating system-directed power management, ACPI
provides a generic system event mechanism for Plug and Play and an operating
system-independent interface for confi guration control. ACPI leverages the Plug
and Play BIOS data structures while providing a processor architecture-independent
implementation that is compatible with Windows XP/Windows 2003/Windows 2008/
Windows Vista Operating Systems.
Slow Blinking LED for Suspend-State Indicator
When the CPU goes into a suspend state, the chassis power LED will start blinking
to indicate that the CPU is in suspend mode. When the user presses any key, the
CPU will wake-up and the LED will automatically stop blinking and remain on.
Main Switch Override Mechanism
When an ATX power supply is used, the power button can function as a system
suspend button to make the system enter a SoftOff state. The monitor will be
suspended and the hard drive will spin down. Pressing the power button again
will cause the whole system to wake-up. During the SoftOff state, the ATX power
supply provides power to keep the required circuitry in the system "alive." In case
the system malfunctions and you want to turn off the power, just press and hold
the power button for 4 seconds. This option can be set in the Power section of the
BIOS Setup routine.
1-6 Power Supply
As with all computer products, a stable power source is necessary for proper and
reliable operation. It is even more important for processors that have high CPU
clock rates.
It is strongly recommended that you use a high quality power supply that meets ATX
power supply Specifi cation 2.02 or above. It must also be SSI compliant (For more
1-11
Page 20
X8DTG-QF User's Manual
information, please refer to the web site at http://www.ssiforum.org/). Additionally, in
areas where noisy power transmission is present, you may choose to install a line
fi lter to shield the computer from noise. It is recommended that you also install a
power surge protector to help avoid problems caused by power surges.
Note 1. For the proprietary 20-pin main power connector (JPW1) and the
8-pin PCI-Exp. Graphic card power connectors (JPW2/JPW3) to work properly , please customize your power cables based on the SMC PWR Connector Pin-Out Defi nitions listed in the tables on Page 2-20 in Chapter 2.
Note 2. For the PCI-Exp. Graphic cards to work properly, please connect
the PCI-E graphic card power connectors (JPW2/JPW3) to the power
supply.
1-7 Overview of the Winbond WPCM450 Controller
The Winbond WPCM450, a Baseboard Management Controller (BMC), supports
the 2D/VGA-compatible Graphics Core with the PCI interface, Virtual Media, and
Keyboard/Video/Mouse (KVM) Redirection modules.
The WPCM450 BMC interfaces with the host system via a PCI interface to communicate with the graphics core. It supports USB 2.0 and 1.1 for remote keyboard/
mouse/virtual media emulation. It also provides LPC interface to control Super IO
functions. The WPCM450 is connected to the network via an external Ethernet
PHY module.
The WPCM450 communicates with onboard components via six SMBus interfaces,
fan control, Platform Environment Control Interface (PECI) buses.
Note: For more information on IPMI confi guration, please refer to the Em-
bedded IPMI User's Guide posted on our website at http://www.supermicro.
com/support/manuals/.
1-8 Super I/O
The Super I/O supports two high-speed, 16550 compatible serial communication
ports (UARTs). Each UART includes a 16-byte send/receive FIFO, a programmable
baud rate generator, complete modem control capability and a processor interrupt
system. Both UARTs provide legacy speed with baud rate of up to 115.2 Kbps
as well as an advanced speed with baud rates of 250 K, 500 K, or 1 Mb/s, which
support higher speed modems.
The Super I/O provides functions that comply with ACPI (Advanced Confi guration
and Power Interface), which includes support of legacy and ACPI power management through an SMI or SCI function pin. It also features auto power management
to reduce power consumption.
1-12
Page 21
Chapter 2: Installation
Chapter 2
Installation
2-1 Static-Sensitive Devices
Electrostatic Discharge (ESD) can damage electronic com ponents. T o prevent damage to your system board, it is important to handle it very carefully. The following
measures are generally suffi cient to protect your equipment from ESD.
Precautions
Use a grounded wrist strap designed to prevent static discharge.•
Touch a grounded metal object before removing the board from the antistatic •
bag.
Handle the board by its edges only; do not touch its components, peripheral
•
chips, memory modules or gold contacts.
When handling chips or modules, avoid touching their pins.
•
Put the motherboard and peripherals back into their antistatic bags when not •
in use.
For grounding purposes, make sure your computer chassis provides excellent
•
conductivity between the power supply, the case, the mounting fasteners and
the motherboard.
Use only the correct type of onboard CMOS battery as specifi ed by the
•
manufacturer. Do not install the onboard battery upside down to avoid possible
explosion.
Unpacking
The motherboard is shipped in antist atic packag i n g t o avo id static da m a ge. When
unpacking the board, make sure the person handling it is static protected.
2-1
Page 22
X8DTG-QF User's Manual
2-2 Motherboard Installation
All motherboards have standard mounting holes to fi t different types of chassis.
Make sure that the locations of all the mounting holes for both motherboard and
chassis match. Although a chassis may have both plastic and metal mounting
fasteners, metal ones are highly recommended because they ground the motherboard to the chassis. Make sure that the metal standoffs click in or are screwed in
tightly. Then use a screwdriver to secure the motherboard onto the motherboard
tray. Note: Some components are very close to the mounting holes. Please take
precautionary measures to prevent damage to these components when installing
the motherboard to the chassis.
Tools Needed
1. Phillips Screwdriver
2. Pan head #6 screws
Locations of Mounting Holes
X8DTG-QF
Rev. 2.0
Installation Instructions
Install the IO shield into the chassis. 1.
Locate the mounting holes on the 2.
motherboard. Refer to the layout
above for mounting hole locations.
Locate the matching mounting holes 3.
on the chassis. Align the mounting
holes on the motherboard against
the mounting holes on the chassis.
Install standoffs in the chassis as needed.4.
Install the motherboard into the chassis carefully to avoid damage to mother-5.
board components.
Warning: To avoid damaging the motherboard and its components, please
do not apply any force greater than 8 lb/sq.in (8 lbs. per square inch) when
installing a screw into a mounting hole.
Insert a Pan head #6 screw into a mounting hole on the motherboard and its 6.
matching mounting hole on the chassis, using a Phillips screwdriver.
Repeat Step 4 to insert #6 screws to all mounting holes.7.
Make sure that the motherboard is securely placed on the chassis.8.
2-2
Page 23
2-3 Processor and Heatsink Installation
!
When handling the processor package, avoid placing direct pressure on
the label area of the fan.
Notes:
Always connect the power cord last and always remove it before adding, re-1.
moving or changing any hardware components. Make sure that you install the
processor into the CPU socket before you install the CPU heatsink.
Make sure to install the motherboard into the chassis before you install the 2.
CPU heatsink and heatsink fans.
When purchasing a motherboard without the 5500/5600 Series processor pre-3.
installed, make sure that the CPU socket plastic cap is in place, and none of
the CPU socket pins are bent; otherwise, contact the retailer immediately.
Chapter 2: Installation
Refer to the M B Features S ecti on for mo re deta ils on CPU s uppor t.4.
Installing an LGA 1366 Processor
Press the socket clip to release 1.
the load plate, which covers the
CPU socket, from its locking
position.
Gently lift the socket clip to 2.
open the load plate.
Hold the plastic cap at its north 3.
and south center edges to remove it from the CPU socket.
Socket Clip
Plastic Cap
Load Plate
Hold the north & south edges of
the plastic cap to remove it
2-3
Page 24
X8DTG-QF User's Manual
After removing the plastic cap, using 4.
your thumb and the index fi nger,
hold the CPU at the north and south
center edges.
Align the CPU key, the semi-circle 5.
cutout, against the socket key, the
notch below the gold color dot on
the side of the socket.
Once both the CPU and the socket 6.
are aligned, carefully lower the CPU
straight down into the socket. (Do
not rub the CPU against the surface
of the socket or its pins to avoid
damaging the CPU or the socket.)
Socket Keys CPU CPU SocketLoad Plate
With the CPU inside the socket, in-7.
spect the four corners of the CPU to
make sure that the CPU is properly
installed.
Once the CPU is securely seated 8.
on the socket, lower the CPU load
plate to the socket.
Use your thumb to gently push the 9.
socket clip down to the clip lock.
Warning: Please save the plastic ca p. The mot her board m ust
be shipped with the plastic cap
properly installed to protect the
CPU socket pins. Shipment
without the plastic cap properly
installed will cause damage to
the socket pins.
CPU Keys
2-4
Page 25
Installing a CPU Heatsink
Do not apply any thermal 1.
grease to the heatsink or the
CPU die because the required
amount has already been preapplied.
Chapter 2: Installation
Place the heatsink on top of the 2.
CPU so that the four mounting
holes are aligned with those on
the retention mechanism.
3. Install two diagonal screws (ie
the #1 and the #2 screws) and
tighten them until just snug (-do
not fully tighten the screws to
avoid possible damage to the
CPU.)
Screw#1
Screw#1
Install Screw#1
Screw#2
Screw#2
4. Finish the installation by fully
tightening all four screws.
2-5
Page 26
X8DTG-QF User's Manual
Removing the Heatsink
Warni ng: We do not recommend that the CPU or the heatsink be removed. However, if you do need to remove the heatsink, please follow
the inst ructions be low to uninstall th e heatsink and prevent da mage to
the CPU or ot her co mpone nts.
Unplug the power cord from the 1.
power supply.
Disconnect the heatsink fan 2.
wires from the CPU fan header.
Using a screwdriver, loosen and 3.
remove the heatsink screws
from the motherboard in the sequence as show in the picture
on the right.
Using a screwdriver to
remove Screw#1
Hold the heatsink as shown 4.
in the picture on the right and
gently wriggle the heatsink to
loosen it from the CPU. (Do not
use excessive force when wriggling the heatsink.)
Once the heatsink is loosened, 5.
remove it from the CPU socket.
To reinstall the CPU and the 6.
heatsink, clean the surface of
the CPU and the heatsink to get
rid of the old thermal grease.
Reapply the proper amount of
thermal grease on the surface
before reinstalling them on the
motherboard.
Remove Screw#2
2-6
Page 27
Chapter 2: Installation
2-4 Memory Installation
Note: Check the S uper micro we b site for r ecom mende d memor y mo dules .
CAUTION
Exercise extreme care when installing or removing DIMM
module s to prevent any po ssib le damag e. Also n ote that th e
memor y is i nterl eaved to imp rove per fo rman ce (See ste p 1).
DIMM Installation
Insert the desired number of DIMMs into the memory slots, starting with 1.
P1-DIMM 1A. For best memory performance, please install memory modules
of the same type and same speed on the memory slots as indicated on the
tables below.
Insert each DIMM module vertically into its slot. Pay attention to the notch 2.
along the bottom of the module to prevent inserting the DIMM module incorrectly.
Gently press down on the DIMM module until it snaps into place in the slot. 3.
Repeat for all modules.
The X8DTG-QF supports up to 192 GB* of Registered ECC or up to 48 GB of Unbuffered ECC/Non-ECC DDR3 1333/1066/800 MHz Memory in 12 DIMMs. (*Refer to
our memory recommendation list posted on our website at www.supermicro.com.)
Note1: For Unbuffered ECC/Non-ECC memory, maximum of 4 GB per
DIMM is supported.
Note 2: memory speed support is dependent on the type of CPU used
on the board.
DIMM Module Population Confi guration
For memor y to wor k pro perl y, follow the tab les be low for me mor y inst allati on.
Memory Support for the Motherboard w/5500 Processors Installed
RDIMM Population for the Motherboard with 5500 Processors Installed
DIMM
Slots per
Channel
21Reg. DDR3 ECC800,1066,1333SR or DR
21Reg. DDR3 ECC800,1066 (Note 1)QR
22Reg. DDR3 ECC800,1066 (Note 1)Mixing SR, DR
22Reg. DDR3 ECC800 (Note 2)Mixing SR, DR, QR
Note 1: 1333 RDIMMs will run at 1066 MHz (-BIOS automatic downgrading).
Note 2: 1333/1066 RDIMMs will run at 800 MHz (-BIOS automatic downgrading).
UDIMM Population for the Motherboard with 5500 Processors Installed
DIMM
Slots per
Channel
21Unb. DDR3 ECC/Non-ECC800,1066,1333SR or DR
22Unb. DDR3 ECC/Non-ECC800,1066 (Note)Mixing SR, DR
Note: 1333 UDIMMs will run at 800 MHz (-BIOS automatic downgrading)
Memory Support for the Motherboard w/5600 Processors Installed
1.5V DIMMs•
1.5V RDIMM Population for the Motherboard w/5600 Processors Installed
DIMM
Slots per
Channel
21Reg. DDR3 ECC800,1066,1333SR or DR
21Reg. DDR3 ECC800 , 1066 (Note 1)QR
22Reg. DDR3 ECC800,1066, 1333 Mixing SR, DR
22Reg. DDR3 ECC800 (Note 2)Mixing SR, DR, QR
Note 1: 1333 RDIMMs MHz will run at 1066 MHz (-BIOS automatic downgrading)
Note 2: 1333/1066 RDIMMs MHz will run at 800 MHz (-BIOS automatic downgrading)
Note 3: MIxing of 1.35V and 1.5V DIMMs is not recommended.
1.5V UDIMM Population for the Motherboard w/5600 Processors Installed
DIMM
Slots per
Channel
21Unb. DDR3 ECC/Non-ECC800,1066,1333SR or DR
22Unb. DDR3 ECC/Non-ECC800,1066, 1333Mixing SR, DR
Note 1: 1333 MHz for two DIMMs per channel is supported when Unbuf./ECC DIMMs are used.
Note 2: MIxing of 1.35V and 1.5V DIMMs is not recommended.
1.35V RDIMM Population for the Motherboard w/5600 Processors
Installed
DIMM
Slots per
Channel
21Reg. DDR3 ECC800,1066,1333SR or DR
21Reg. DDR3 ECC800 (Note 1)QR
22Reg. DDR3 ECC800,1066 (Note 2)Mixing SR, DR
22Reg. DDR3 ECC800 (Note 3)Mixing SR, DR, QR
Note 1: 1333/1066 QR RDIMMs MHz will run at 800 MHz (-BIOS automatic downgrading)
Note 2: 1333 SR/DR RDIMMs MHz will run at 800 MHz (-BIOS automatic downgrading)
Note 3: 1333 SR/DR/QR RDIMMs MHz will run at 800 MHz (-BIOS automatic downgrading)
Note 4: MIxing of 1.35V and 1.5V DIMMs is not recommended.
Note 1: Due to OS limitations, some operating systems may not show
more than 4 GB of memory.
Note 2: Due to memory allocation to system devices, the amount of mem-
ory that remains available for operational use will be reduced when 4 GB
of R AM is us ed. The r educt ion in m emor y avai labili ty is di spro por tio nal.
Possible System Memory Allocation & Availability
System DeviceSizePhysical Memory Available
Firmware Hub fl ash memory (System BIOS)1 MB3.99 GB
Local APIC4 KB3.99 GB
Area Reserved for the chipset2 MB3.99 GB
I/O APIC (4 Kbytes)4 KB3.99 GB
PCI Enumeration Area 1256 MB3.76 GB
PCI Express (256 MB)256 MB3.51 GB
PCI Enumeration Area 2 (if needed) -Aligned on 256-M
boundaryVGA Memory16 MB2.85 GB
TSEG1 MB2.84 GB
Memory available for the OS & other applications 2.84 GB
512 MB3.01 GB
(4 GB Total System Memory)
2-10
Page 31
Installing and Removing DIMMs
Chapter 2: Installation
X8DTG-QF
Rev. 2.0
Release Tab
Notch
Release
Tab
DIMM DDR3
Note: Notch
should align
with the
receptive point
on the slot
Notch
Release
Tab
To Install : Insert module vertically and press down until
it snaps i nto pl ace. Pay at ten tio n to the a lign ment n otch
at the bottom.
3
Release Tab
To Remove:
Use your thumbs
to gently push
the release tabs
near both ends of
the module. This
should release it
from the slot.
2-11
Page 32
X8DTG-QF User's Manual
1
2
3
4
5
6
7
8
9
2-5 Control Panel Connectors/IO Ports
The I/O p ort s are col or cod ed in co nforma nce wit h the PC 9 9 speci fi cation. See
the pic ture be low for t he co lors a nd loc atio ns of the var ious I /O por t s.
Back Panel Connectors/IO Ports
Back Panel Connectors
Keyboard (Purple)1.
PS/2 Mouse (Green)2.
COM Port 1 (Turquoise)3.
VGA (Blue) 4.
X8DTG-QF
Rev. 2.0
USB 05.
USB16.
IPMI_Dedicated LAN7.
11
10
USB 28.
USB 39.
USB 410.
USB 511.
LAN 212.
LAN 113.
Side_surround14.
Back_surround15.
CEN/LFE16.
Microphone_In17.
Front18.
Line_In19.
19
13
16
2-12
12
15
14
18
17
Page 33
Back Panel Connector Pin Defi nitions
123
4
5
6
789
Chapter 2: Installation
Universal Serial Bus (USB)
Six Universal Serial Bus ports (USB
0/1, 2/3/4/5) are located on the I/O
back panel. Additional four USB connections (USB 6, 7, 8/9) are used to
provide front chassis access. Connect
USB cables to these USB ports/headers to use USB connections. (USB
cables are not included). See the
tables on the right for pin defi nitions.
Two Ethernet ports are located next to the
USB 2~5 on the IO Backplane. In addition, an IPMI Dedicated LAN is located
above the USB ports 0/1. These ports
accept RJ45 type cables.
Note:
Please refer to the LED In-
dicator Section for LAN LED
information.
LAN Ports
Pin Defi nition
Pin# Defi nition Pin# Defi nitions
1P2V5SB10SGND
2TD0+11Act LED
Two COM connections (COM1 &
COM2) are located on the motherboard.
COM1 is located on the Backplane IO
panel. COM2 is header located next to
PCI-E Slot 1 to provide additional serial
connection support. See the table on
the right for pin defi nitions.
Video Connector
A V ideo (VGA) connector is above COM
1 on the IO backplane. This connector is
used to provide video and CRT display.
Refer to the board layout below for the
location.
This motherboard features a 7.1+2 Channel High Defi nition Audio (HDA) codec that
provides 10 DAC channels. The HD Audio
connections simultaneously supports multiplestreaming 7.1 sound playback with 2 channels
of independent stereo output for front L&R, rear
L&R, center and subwoofer speakers. Use the
software included in the CD-ROM with your
motherboard to use this feature.
CD & 10-pin Audio Headers
A 4-pin CD header (CD1) and a 10-pin Front
Panel Audio header (J138) are also located on
the motherboard. These headers allow you to
use the onboard sound for audio CD playback.
Connect an audio cable from your CD drive to
the CD header that fi ts your cable's connector.
See the tables at right for pin defi nitions for
these headers.
X8DTG-QF
Rev. 2.0
HD Audio
(BP) HD Audio
Conn# Signal
1Side_Surround
2Back_Surround
3CEN/LFE
4Microphone_In
5Front
6Line_In
JF1 contains header pins for various buttons and indicators that are normally located on a control panel at the front of the chassis. These connectors are designed
specifi cally for use with Supermicro server chassis. See the fi gure below for the
descriptions of the various control panel buttons and LED indicators. Refer to the
following section for descriptions and pin defi nitions.
JF1 Header Pins
1920
Ground
X
NMI
X
Power LED
HDD LED
NIC1 LED
NIC2 LED
OH/Fan Fail LED
PWR Fail LED
Ground
Ground
Vcc
Vcc
Vcc
Vcc
Vcc
Vcc
Reset
Reset Button
Power Button
PWR
1
2
X8DTG-QF
Rev. 2.0
2-17
Page 38
X8DTG-QF User's Manual
Front Control Panel Pin Defi nitions
NMI Button
The non-maskable interrupt button header is
located on pins 19 and 20 of JF1. Refer to the
table on the right for pin defi nitions.
Power LED
The Power LED connection is l o cated on pi n s
15 and 16 of JF1. Refer to the t able on the
right fo r pin defi nitions.
NMI Button
Pin Defi nitions (JF1)
Pin# Defi nition
19Control
20Ground
Power LED
Pin Defi nitions (JF1)
Pin# Defi nition
15+5V
16Ground
X8DTG-QF
Rev. 2.0
Ground
X
B
Power LED
HDD LED
NIC1 LED
NIC2 LED
OH/Fan Fail LED
PWR Fail LED
Ground
Ground
A. NMI
B. PWR LED
1920
NMI
X
Vcc
Vcc
Vcc
Vcc
Vcc
Vcc
Reset
PWR
1
2
A
Reset Button
Power Button
2-18
Page 39
HDD LED
The HDD LED connection is located on pins 13
and 14 of JF1. Attach a hard drive LED cable
here to display any South Bridge-related HDD
activities, including SAS, Serial ATA and IDE.
See the table on the right for pin defi nitions.
NIC1/NIC2 LED Indicators
The NIC (Network Interface Controller) LED
connections for GLAN Port 1 are located on
pins 1 1 and 12, and for GLAN Port 2 are on pins
9 and 10 of JF1. Attach NIC LED cables to display LAN port connections and activities. Refer
to the table on the right for pin defi nitions.
Chapter 2: Installation
HDD LED
Pin Defi nitions (JF1)
Pin# Defi nition
13+5V
14HD Active
GLAN1 LED
Pin Defi nitions (JF1)
Pin# Defi nition
11NIC1 Activity
12NIC1 Link
GLAN2 LED
Pin Defi nitions (JF1)
Pin# Defi nition
9NIC2 Activity
10NIC2 Link
X8DTG-QF
Rev. 2.0
Ground
X
Power LED
HDD LED
A
NIC1 LED
B
NIC2 LED
C
OH/Fan Fail LED
PWR Fail LED
Ground
Ground
A. HDD LED
B. NIC1 LED
C. NIC2 LED
1920
NMI
X
Vcc
Vcc
Vcc
Vcc
Vcc
Vcc
Reset
PWR
1
2
Reset Button
Power Button
2-19
Page 40
X8DTG-QF User's Manual
Overheat (OH)/Fan Fail LED
Connect an LED cable to the OH/Fan Fail
connections on pins 7 and 8 of JF1 to provide
advanced warnings for chassis overheat/fan
failure. Refer to the table on the right for pin
defi nitions.
Power Fail LED
The Power Fail LED c onne cti on is lo cate d on
pins 5 and 6 of J F1. Refer to the table on t he
right fo r pin defi nitions.
OH/Fan Fail LED
Pin Defi nitions (JF1)
Pin# Defi nition
7Vcc
8OH/Fan Fail LED
OH/Fan Fail Indicator
Status
State Defi nition
OffNormal
OnOverheat
Flash-
ing
Pin Defi nitions (JF1)
Pin# Defi nition
53.3V
6PWR Fail LED
Fan Fail
PWR Fail LED
X8DTG-QF
Rev. 2.0
2-20
Power LED
HDD LED
NIC1 LED
NIC2 LED
OH/Fan Fail LED
A
PWR Fail LED
B
A. OH/Fan Fail/PWR Fail/LED
B. PWR Supply Fail
1920
Ground
X
Ground
Ground
2
NMI
X
Vcc
Vcc
Vcc
Vcc
Vcc
Vcc
Reset
Reset Button
Power Button
PWR
1
Page 41
Chapter 2: Installation
Reset Button
The Reset Button connection is located on pins
3 and 4 of JF1. Attach it to a hardware reset
switch on the computer case. Refer to the table
on the right for pin defi nitions.
Power Button
The Power Button connection is located on
pins 1 and 2 of JF1. Momentarily contacting
both pins will power on/off the system. This
button can also be confi gured to function as
a suspend button (with a setting in the BIOS see Chapter 4). Press the button for at least 4
seconds to turn off the power supply when in
the suspend mode,. Refer to the table on the
right for pin defi nitions.
Reset Button
Pin Defi nitions (JF1)
Pin# Defi nition
3Reset
4Ground
Power Button
Pin Defi nitions (JF1)
Pin# Defi nition
1PWR
2Ground
X8DTG-QF
Rev. 2.0
2-21
Ground
X
Power LED
HDD LED
NIC1 LED
NIC2 LED
OH/Fan Fail LED
PWR Fail LED
Ground
Ground
A. Reset Button
B. PWR Button
1920
NMI
X
Vcc
Vcc
Vcc
Vcc
Vcc
Vcc
Reset
PWR
2
1
A
Reset Button
B
Power Button
Page 42
X8DTG-QF User's Manual
2-6 Connecting Cables
Power Connectors
A 24-pin main power supply connector(JPW1)
and two 8-pin CPU PWR connectors (JPW2/
JPW3) on the motherboard. These power
connectors meet the SSI EPS 12V specifi ca-
tion. All these three power connectors must
be connected to your power supply to ensure
adequate power supply to your system. See
the table on the right for pin defi nitions.
Warning: To prevent damage to the
power supply or motherboard, please
use a power supply that contains a
24-pin and two 8-pin power connectors. Be sure to connect these connectors to the 24-pin (JPW1) and the
two 8-pin (JPW2,JPW3) power connectors on the motherboard. Failure
in doing so will void the manufacturer
warranty on your power supply and
motherboard.
A. 24-pin ATX PWR (Req'd)
B/C.8-pin Processor PWR
(Req'd)
2-22
Page 43
Chapter 2: Installation
D
G
F
E
I
Fan Headers
The X8DTG-QF has ten chassis/system fan
headers (Fan1 ~ Fan10) on the motherboard.
Fan 7 and Fan 8 are CPU Fans. All these are
4-pin fans headers which are backward compatible with the traditional 3-pin fans. However,
fan speed control is available for 4-pin fans
only . The fan speeds are controlled by Thermal
Management via Hardware Monitoring in the
Advanced Setting in the BIOS. (The Default
setting is Disabled.) See the table on the right
for pin defi nitions.
C. Fan3
D. Fan4
E. Fan5
F. Fan6
G. Fan7 (CPU 1 Fan)
H. Fan8 (CPU 2 Fan)
I. Fan 9
J. Fan 10
2-23
Page 44
X8DTG-QF User's Manual
Power LED/Speaker
On JD1 header, pins 1~3 are used for power
LED indicator and pins 4~7 are for the speaker.
Connect a cable to pins 4~7 of JD1 to use an
external speaker. If you wish to use the internal
speaker, please close pins 6~7 with a jumper.
See the tables on the right for pin defi nitions.
Internal Buzzer
The Internal Buzzer, located at SP1, can be
used to provide audible alarms for various beep
codes. See the table on the right for pin defi ni-
tions. Refer to the layout below for the locations
of the Internal Speaker/Buzzer.
A Chassis Intrusion header is located at JL1 on
the motherboard. Attach an appropriate cable
from the chassis to inform you of a chassis
intrusion when the chassis is opened.
T-SGPIO Headers
Two SGPIO (Serial-Link General Purpose Input/Output) headers (T-SGPIO-1/T-SGPIO-2)
are located on the motherboard. These
headers support serial link interfaces for the
onboard SATA connectors. See the table on
the right for pin defi nitions. Refer to the board
layout below for the location.
C) Connector
(JSMB1) monitors power supply, fan and system temperatures. See the table on the right
for pin defi nitions.
Power SMB (I2C) Connector
Power System Management Bus (I
nector (JPI
2
C) monitors power supply, fan and
2
C) Con-
system temperatures. See the table on the right
for pin defi nitions.
PWR SMB
Pin Defi nitions
Pin# Defi nition
1Clock
2Data
3PWR Fail
4Ground
PWR SMB
Pin Defi nitions
Pin# Defi nition
1Clock
2Data
3PWR Fail
4Ground
5+3.3V
KB/MOUSE
VGA
USB0/1
USB2/3/4/5
LAN2
J138
CD1
Audio CTRL
ALC888
JL2
1
D33
IPMI
Firmware
WPCM450
BMC CTRL
FAN6
COM1
AUDIO FP
CD-IN
JPAC
Memory
for IPMI
COM2
FAN5
IPMI_LAN
LAN1
82574
LAN CTRL
JAUDIO1
82574
LAN CTRL
JPUSB1
PHY
CPU
VRM
JPL2
Slot11 PCI-E 2.0 x4(in x8 Slot)
Slot10 PCI-E 2.0 x16
JPL1
JI2C2
JI2C1
JPG1
Slot6 PCI-E 2.0 x16
Slot5 PCI 33MHz
Slot4 PCI-E 2.0 x16
Slot3 PCI 33MHz
Slot2 PCI-E 2.0 x4(in x16 Slot)
Slot1 PCI-E x4(in x16 Slot)
FAN8/CPU2
Slot8 PCI-E 2.0 x16
P2-DIMM3A
P2-DIMM3B
P2-DIMM2A
P2-DIMM2B
P2-DIMM1A
P2-DIMM1B
ALWAYS POPULATE DIMM A FIRST
CPU2
X8DTG-QF
Rev. 2.0
1
A
JSMB1
JWOL
JWD
B
PWR I2C
FAN7/CPU1
JPI2C
ALWAYS POPULATE DIMM A FIRST
Intel 5520
IOH-36D
JBT1
BIOS
JP3
JP6
Intel
ICH 10R
J18
TPM
JTPM1
FAN9
JPW2
T-SGPIO1
P1-DIMM1B
P1-DIMM1A
P1-DIMM2B
P1-DIMM2A
P1-DIMM3B
P1-DIMM3A
Intel 5520
IOH-36D
CPU1
T-SGPIO2
JPW1
JPW3
FAN1
FAN2
JD1
FAN3
FAN10
SP1
DP1
FP CTRL
JF1
JOH1
USB7
USB6
Battery
JPUSB2
USB8/9
FAN4
I-SATA4
I-SATA5
JL1
I-SATA0
I-SATA2
I-SATA1
I-SATA3
A. SMB
B. PWR SMB
2-26
Page 47
Chapter 2: Installation
Overheat LED/Fan Fail (JOH1)
The JOH1 header is used to connect an LED
indic ator to p rovi de warn ings o f chas sis ove rheating or fan failure. This LED will blink when
a fan failure occurs. Refer to the table on right
for pin de fi nitions.
Wake-On-LAN
The Wake-On-LAN header is located at JWOL
on the motherboard. You must also have a
LAN card with a Wake-On-LAN connector and
a cable to use this feature. See the table on
the right for pin defi nitions.
Overheat LED
Pin Defi nitions
Pin# Defi nition
15vDC
2OH Active
OH/Fan Fail LED
Pin Defi nitions
State Message
SolidOverheat
BlinkingFan Fail
Wake-On-LAN
Pin Defi nitions
Pin# Defi nition
1+5V Standby
2Ground
3Wake-up
KB/MOUSE
VGA
USB0/1
USB2/3/4/5
LAN2
J138
CD1
Audio CTRL
ALC888
JL2
IPMI
Firmware
1
D33
FAN6
COM1
AUDIO FP
CD-IN
JAUDIO1
LAN CTRL
JPAC
WPCM450
BMC CTRL
Memory
for IPMI
COM2
FAN5
IPMI_LAN
LAN1
82574
LAN CTRL
82574
JPUSB1
PHY
FAN8/CPU2
CPU
VRM
JPL2
Slot11 PCI-E 2.0 x4(in x8 Slot)
Slot10 PCI-E 2.0 x16
JPL1
Slot8 PCI-E 2.0 x16
JI2C2
JI2C1
JPG1
Slot6 PCI-E 2.0 x16
Slot5 PCI 33MHz
Slot4 PCI-E 2.0 x16
Slot3 PCI 33MHz
Slot2 PCI-E 2.0 x4(in x16 Slot)
Slot1 PCI-E x4(in x16 Slot)
P2-DIMM3A
P2-DIMM3B
P2-DIMM2A
P2-DIMM2B
P2-DIMM1A
P2-DIMM1B
ALWAYS POPULATE DIMM A FIRST
CPU2
X8DTG-QF
Rev. 2.0
1
B
JSMB1
JWOL
JWD
PWR I2C
FAN7/CPU1
JPI2C
ALWAYS POPULATE DIMM A FIRST
Intel 5520
IOH-36D
JBT1
BIOS
JP3
JP6
Intel
ICH 10R
J18
TPM
JTPM1
FAN9
JPW2
T-SGPIO1
P1-DIMM1B
P1-DIMM1A
P1-DIMM2B
P1-DIMM2A
P1-DIMM3B
P1-DIMM3A
Intel 5520
IOH-36D
CPU1
T-SGPIO2
JPW1
JPW3
FAN1
FAN2
JD1
FAN3
FAN10
SP1
DP1
FP CTRL
JF1
A
JOH1
USB7
USB6
Battery
JPUSB2
USB8/9
FAN4
I-SATA4
I-SATA5
JL1
I-SATA0
I-SATA2
I-SATA1
I-SATA3
A. OH/Fan Fail LED
B. WOL
2-27
Page 48
X8DTG-QF User's Manual
Trusted Platform Module Header
A Trusted Platform Module (TPM)
header (JTPM1) is located close to the
ICH-10R South Bridge. This header
provides TPM support to ensure data
integrity and system security. Refer
to the table on the right for pin defi ni-
tions.
19LPCPD# (X)20LDRQ#(X)
Notes:
(X)=TPM does not use the signals.
2
SCL, SDAT are I
C bus clock and data.
KB/MOUSE
VGA
USB0/1
USB2/3/4/5
LAN2
J138
CD1
Audio CTRL
ALC888
JL2
1
D33
IPMI
Firmware
WPCM450
BMC CTRL
FAN6
COM1
AUDIO FP
CD-IN
JPAC
Memory
for IPMI
COM2
FAN5
IPMI_LAN
LAN1
82574
LAN CTRL
JAUDIO1
82574
LAN CTRL
JPUSB1
PHY
CPU
VRM
JPL2
Slot11 PCI-E 2.0 x4(in x8 Slot)
Slot10 PCI-E 2.0 x16
JPL1
JI2C2
JI2C1
JPG1
Slot6 PCI-E 2.0 x16
Slot5 PCI 33MHz
Slot4 PCI-E 2.0 x16
Slot3 PCI 33MHz
Slot2 PCI-E 2.0 x4(in x16 Slot)
Slot1 PCI-E x4(in x16 Slot)
FAN8/CPU2
Slot8 PCI-E 2.0 x16
P2-DIMM3A
P2-DIMM3B
P2-DIMM2A
P2-DIMM2B
P2-DIMM1A
P2-DIMM1B
ALWAYS POPULATE DIMM A FIRST
CPU2
X8DTG-QF
Rev. 2.0
1
JSMB1
JWOL
JWD
PWR I2C
FAN7/CPU1
JPI2C
ALWAYS POPULATE DIMM A FIRST
Intel 5520
IOH-36D
JBT1
BIOS
JP3
JP6
Intel
ICH 10R
J18
A
TPM
JTPM1
FAN9
JPW2
T-SGPIO1
P1-DIMM1B
P1-DIMM1A
P1-DIMM2B
P1-DIMM2A
P1-DIMM3B
P1-DIMM3A
Intel 5520
IOH-36D
CPU1
T-SGPIO2
JPW1
JPW3
FAN1
FAN2
JD1
FAN3
FAN10
SP1
DP1
FP CTRL
JF1
JOH1
USB7
USB6
Battery
JPUSB2
USB8/9
FAN4
I-SATA4
I-SATA5
JL1
I-SATA0
I-SATA2
I-SATA1
I-SATA3
A. TPM
2-28
Page 49
2-7 Jumper Settings
Connector
Pins
Jumper
Cap
Setting
Explanation of Jumpers
To modify the operation of the motherboard,
jumpers can be used to choose between optional settings. Jumpers create shorts between
two pins to change the function of the connector. Pin 1 is identifi ed with a square solder pad
on the printed circuit board. See the motherboard layout pages for jumper locations.
Note: On two pin ju mpers, " Closed"
means the jumper is on and "Open"
means th e jumpe r is of f the pi ns.
Chapter 2: Installation
3 2 1
3 2 1
Pin 1-2 short
GLAN Enable/Disable
JPL1/JPL2 en able or disable the GLAN Ports
1/2 on the mot her boar d. See t he tab le on t he
right f or jump er set ting s.
KB/MOUSE
VGA
USB0/1
USB2/3/4/5
LAN2
J138
CD1
Audio CTRL
ALC888
JL2
IPMI
Firmware
1
D33
FAN6
COM1
AUDIO FP
CD-IN
JAUDIO1
LAN CTRL
JPAC
WPCM450
BMC CTRL
Memory
for IPMI
COM2
FAN5
IPMI_LAN
LAN1
82574
LAN CTRL
82574
JPUSB1
PHY
CPU
VRM
JPL2
Slot11 PCI-E 2.0 x4(in x8 Slot)
B
Slot10 PCI-E 2.0 x16
JPL1
A
JI2C2
JI2C1
JPG1
Slot6 PCI-E 2.0 x16
Slot5 PCI 33MHz
Slot4 PCI-E 2.0 x16
Slot2 PCI-E 2.0 x4(in x16 Slot)
FAN8/CPU2
Slot8 PCI-E 2.0 x16
Slot3 PCI 33MHz
Slot1 PCI-E x4(in x16 Slot)
P2-DIMM3A
P2-DIMM3B
P2-DIMM2A
P2-DIMM2B
P2-DIMM1A
P2-DIMM1B
ALWAYS POPULATE DIMM A FIRST
CPU2
X8DTG-QF
Rev. 2.0
1
JSMB1
JWOL
JWD
PWR I2C
FAN7/CPU1
JPI2C
ALWAYS POPULATE DIMM A FIRST
Intel 5520
IOH-36D
JBT1
BIOS
JP3
JP6
Intel
ICH 10R
J18
TPM
JTPM1
FAN9
JPW2
T-SGPIO1
P1-DIMM1B
P1-DIMM1A
P1-DIMM2B
P1-DIMM2A
P1-DIMM3B
P1-DIMM3A
Intel 5520
IOH-36D
CPU1
T-SGPIO2
JPW1
Battery
I-SATA4
I-SATA5
GLAN Enable
Jumper Settings
Pin# Defi nition
1-2Enabled (default)
2-3Disabled
JPW3
FAN1
FAN2
JD1
FAN3
FAN10
SP1
DP1
FP CTRL
JF1
JOH1
USB7
USB6
JPUSB2
USB8/9
FAN4
JL1
I-SATA0
I-SATA2
I-SATA1
I-SATA3
A. JPL1
B. JPL2
2-29
Page 50
X8DTG-QF User's Manual
CMOS Clear
JBT1 is used to clear CMOS. Instead of pins, this "jumper" consists of contact
pads to prevent t he accident al clearin g of CMOS. To clear CMOS , use a metal
objec t such as a sma ll screwdr iver to touc h both pad s at the same t ime to shor t
the co nnec ti on. A lways rem ove the AC p ower c ord f rom t he syste m befo re cl earing CMOS.
Note 1. For an ATX power supply, you must completely shut down the
system, remove the AC power cord and then short JBT1 to clear CMOS.
Note 2. Be sure to remove the onboard CMOS Battery before you short
JBT1 to clear CMOS.
Watch Dog Enable/Disable
Watch Dog (JWD) is a system monitor that can
reboot the system when a software application
hangs. Close Pins 1-2 to reset the system if an
applic ati on h ang s. Cl os e Pins 2- 3 to g ene rate
a non- maskabl e interru pt signal for t he appli catio n that hangs. See th e table on the ri ght
for jumpe r settings . Watch Dog must also b e
enabled in the BIOS.
KB/MOUSE
VGA
USB0/1
USB2/3/4/5
LAN2
J138
CD1
Audio CTRL
ALC888
JL2
1
D33
IPMI
Firmware
WPCM450
BMC CTRL
FAN6
COM1
AUDIO FP
CD-IN
JPAC
Memory
for IPMI
COM2
FAN5
IPMI_LAN
LAN1
82574
LAN CTRL
JAUDIO1
82574
LAN CTRL
JPUSB1
PHY
CPU
VRM
JPL2
Slot11 PCI-E 2.0 x4(in x8 Slot)
Slot10 PCI-E 2.0 x16
JPL1
JI2C2
JI2C1
JPG1
Slot5 PCI 33MHz
ALWAYS POPULATE DIMM A FIRST
FAN8/CPU2
Slot8 PCI-E 2.0 x16
Slot6 PCI-E 2.0 x16
Slot4 PCI-E 2.0 x16
Slot3 PCI 33MHz
Slot2 PCI-E 2.0 x4(in x16 Slot)
Slot1 PCI-E x4(in x16 Slot)
P2-DIMM3A
P2-DIMM3B
P2-DIMM2A
P2-DIMM2B
P2-DIMM1A
P2-DIMM1B
CPU2
JWOL
X8DTG-QF
Rev. 2.0
B
JSMB1
JWD
PWR I2C
Intel 5520
IOH-36D
FAN7/CPU1
JPI2C
ALWAYS POPULATE DIMM A FIRST
JPW1
JPW2
CPU1
P1-DIMM1B
P1-DIMM1A
P1-DIMM2B
P1-DIMM2A
P1-DIMM3B
P1-DIMM3A
FAN9
Intel 5520
IOH-36D
A
JBT1
BIOS
JP3
1
JP6
Intel
ICH 10R
J18
TPM
JTPM1
T-SGPIO1
T-SGPIO2
Battery
I-SATA4
I-SATA5
Watch Dog
Jumper Settings
Jumper Setting Defi nition
Pins 1-2Reset
(default)
Pins 2-3NMI
OpenDisabled
JPW3
FAN1
FAN2
JD1
FAN3
FAN10
SP1
DP1
FP CTRL
JF1
JOH1
USB7
USB6
JPUSB2
USB8/9
FAN4
JL1
I-SATA0
I-SATA2
I-SATA1
I-SATA3
A. CMOS Clear
B. WD
2-30
Page 51
Chapter 2: Installation
I2C Bus to PCI-Exp. Slots
Jumpers JI
the System Management Bus (I
2
C1 and JI2C2 allow you to connect
2
C) to PCI and
PCI-Express slots. These two jumpers are to
be set at the same time. The default setting is
Open to disable the connections. See the table
on the right for jumper settings.
Audio Mode Select
Jumper JL2 allows you to select the Audio
mode. You can choose using AC '97 Audio or
HD (High-defi nition) Audio. The default setting
is Open to use HD Audio. See the table on the
right for jumper settings.
JPUSB1/JPUSB2 jum per s all ow you to " wake
up" the syste m by pres sin g a key on the U SB
keyboard or by clicking the USB mouse of your
system. J PUSB1 is used for Ba ckpanel US B
Ports #0~5, and JPUSB2 is for Front Panel
USB Ports #6~9. These jumpers are used
in conjunction with the USB Wake-Up function in the BIOS. See the table on the right
for jumper settings and jumper connections.
(JPUSB1: Default: Enabled, JPUSB2: Default:
Disabled.)
VGA Enable
JPG1 allows you to enable or disable the
onboard VGA connection supported by the
onboard VGA Controller. The default position is
on pins 1 and 2 to enable VGA. See the table
on the right for jumper settings.
Backpanel USB Wake-
Up Enable (JPUSB1)
Jumper Settings
Pin# Defi nition
1-2Enabled (default)
2-3Disabled
FP USB Wake-up Enable
(JPUSB2)
Jumper Settings
Pin# Defi nition
1-2Enabled
2-3Disabled (Default)
VGA Enable/Disable
Jumper Settings (JPG1)
Both Jumpers Defi nition
Pins 1-2Enabled
Pins 2-3Disabled
KB/MOUSE
VGA
USB0/1
USB2/3/4/5
LAN2
J138
CD1
Audio CTRL
ALC888
JL2
1
D33
IPMI
Firmware
WPCM450
BMC CTRL
FAN6
COM1
AUDIO FP
CD-IN
JPAC
Memory
for IPMI
COM2
FAN5
IPMI_LAN
LAN1
82574
LAN CTRL
JAUDIO1
82574
LAN CTRL
A
JPUSB1
PHY
CPU
VRM
JPL2
Slot11 PCI-E 2.0 x4(in x8 Slot)
Slot10 PCI-E 2.0 x16
JPL1
JI2C2
JI2C1
JPG1
B
Slot6 PCI-E 2.0 x16
Slot5 PCI 33MHz
Slot4 PCI-E 2.0 x16
Slot3 PCI 33MHz
Slot2 PCI-E 2.0 x4(in x16 Slot)
Slot1 PCI-E x4(in x16 Slot)
FAN8/CPU2
Slot8 PCI-E 2.0 x16
P2-DIMM3A
P2-DIMM3B
P2-DIMM2A
P2-DIMM2B
P2-DIMM1A
P2-DIMM1B
ALWAYS POPULATE DIMM A FIRST
CPU2
X8DTG-QF
Rev. 2.0
1
JSMB1
JWOL
JWD
PWR I2C
FAN7/CPU1
JPI2C
ALWAYS POPULATE DIMM A FIRST
Intel 5520
IOH-36D
JBT1
BIOS
JP3
JP6
Intel
ICH 10R
J18
TPM
JTPM1
FAN9
JPW2
T-SGPIO1
P1-DIMM1B
P1-DIMM1A
P1-DIMM2B
P1-DIMM2A
P1-DIMM3B
P1-DIMM3A
Intel 5520
IOH-36D
CPU1
T-SGPIO2
JPW1
JPW3
FAN1
FAN2
JD1
FAN3
FAN10
SP1
DP1
FP CTRL
JF1
JOH1
USB7
USB6
Battery
JPUSB2
USB8/9
FAN4
I-SATA4
I-SATA5
JL1
I-SATA0
I-SATA2
I-SATA1
I-SATA3
A. BP USB Enable
B. VGA Enable
2-32
Page 53
Chapter 2: Installation
Audio Enable
JPAC allows you to enable or disable the onboard audio connection. The default position is
on pins 1 and 2 to enable audio support. See
the table on the right for jumper settings.
Audio Enable/Disable
Jumper Settings (JPG1)
Both Jumpers Defi nition
Pins 1-2Enabled
Pins 2-3Disabled
KB/MOUSE
VGA
USB0/1
USB2/3/4/5
LAN2
J138
CD1
Audio CTRL
ALC888
JL2
IPMI
Firmware
1
D33
FAN6
COM1
AUDIO FP
CD-IN
JAUDIO1
LAN CTRL
JPAC
WPCM450
BMC CTRL
Memory
for IPMI
COM2
FAN5
IPMI_LAN
LAN1
82574
LAN CTRL
82574
JPUSB1
PHY
A
FAN8/CPU2
CPU
VRM
JPL2
Slot11 PCI-E 2.0 x4(in x8 Slot)
Slot10 PCI-E 2.0 x16
JPL1
Slot8 PCI-E 2.0 x16
JI2C2
JI2C1
JPG1
B
Slot6 PCI-E 2.0 x16
Slot5 PCI 33MHz
Slot4 PCI-E 2.0 x16
Slot3 PCI 33MHz
Slot2 PCI-E 2.0 x4(in x16 Slot)
Slot1 PCI-E x4(in x16 Slot)
P2-DIMM3A
P2-DIMM3B
P2-DIMM2A
P2-DIMM2B
P2-DIMM1A
P2-DIMM1B
ALWAYS POPULATE DIMM A FIRST
CPU2
X8DTG-QF
Rev. 2.0
1
JSMB1
JWOL
JWD
PWR I2C
FAN7/CPU1
JPI2C
ALWAYS POPULATE DIMM A FIRST
Intel 5520
IOH-36D
JBT1
BIOS
JP3
JP6
Intel
ICH 10R
J18
TPM
JTPM1
FAN9
JPW2
T-SGPIO1
P1-DIMM1B
P1-DIMM1A
P1-DIMM2B
P1-DIMM2A
P1-DIMM3B
P1-DIMM3A
Intel 5520
IOH-36D
CPU1
T-SGPIO2
JPW1
JPW3
FAN1
FAN2
JD1
FAN3
FAN10
SP1
DP1
FP CTRL
JF1
JOH1
USB7
USB6
Battery
JPUSB2
USB8/9
FAN4
I-SATA4
I-SATA5
JL1
I-SATA0
I-SATA2
I-SATA1
I-SATA3
A. Audio Enable
2-33
Page 54
X8DTG-QF User's Manual
2-8 Onboard Indicators
GLAN LEDs
There are two GLAN ports on the motherboard.
An additional IPMI dedicated LAN port is
also located above the USB 0/1 ports on the
backpanel. Each Gigabit Ethernet LAN port has
two LEDs. The yellow LED indicates activity,
while the Link LED may be green, amber or off
to indicate the speed of the connection. See the
tables at right for more information.
Note: IPMI dedicated LAN does not
operate at 1 Gbps.
Activity
LED
Activity
LED
Link
LED
Link
LED
Rear View (when facing the
rear side of the chassis)
GLAN Activity Indicator
LED Settings
Color Status Defi nition
GreenFlashingActive
GLAN Link Indicator
LED Settings
LED Color Defi nition
OffNo Connection or 10 Mbps
Green100 Mbps
Amber1 Gbps
FAN5
KB/MOUSE
FAN6
JPUSB1
VGA
COM1
C
USB0/1
IPMI_LAN
PHY
USB2/3/4/5
A
B
LAN1
LAN2
AUDIO FP
J138
CD1
CD-IN
CPU
VRM
82574
LAN CTRL
JAUDIO1
JPL2
Slot11 PCI-E 2.0 x4(in x8 Slot)
82574
LAN CTRL
Slot10 PCI-E 2.0 x16
JPL1
JPAC
JI2C2
JI2C1
JPG1
Slot5 PCI 33MHz
COM2
JL2
1
D33
Audio CTRL
ALC888
IPMI
Firmware
WPCM450
BMC CTRL
Memory
for IPMI
ALWAYS POPULATE DIMM A FIRST
FAN8/CPU2
Slot8 PCI-E 2.0 x16
Slot6 PCI-E 2.0 x16
Slot4 PCI-E 2.0 x16
Slot3 PCI 33MHz
Slot2 PCI-E 2.0 x4(in x16 Slot)
Slot1 PCI-E x4(in x16 Slot)
P2-DIMM3A
P2-DIMM3B
P2-DIMM2A
P2-DIMM2B
P2-DIMM1A
P2-DIMM1B
CPU2
JWOL
X8DTG-QF
Rev. 2.0
JSMB1
JWD
PWR I2C
FAN7/CPU1
JPI2C
ALWAYS POPULATE DIMM A FIRST
Intel 5520
IOH-36D
JBT1
BIOS
JP3
1
JP6
Intel
ICH 10R
J18
TPM
JTPM1
FAN9
JPW2
T-SGPIO1
P1-DIMM1B
P1-DIMM1A
P1-DIMM2B
P1-DIMM2A
P1-DIMM3B
P1-DIMM3A
Intel 5520
IOH-36D
CPU1
T-SGPIO2
JPW1
JPW3
FAN1
FAN2
JD1
FAN3
FAN10
SP1
DP1
FP CTRL
JF1
JOH1
USB7
USB6
Battery
JPUSB2
USB8/9
FAN4
I-SATA4
I-SATA5
JL1
I-SATA0
I-SATA2
I-SATA1
I-SATA3
A. LAN 1
B. LAN 2
C. IPMI dedicated LAN
2-34
Page 55
Chapter 2: Installation
Onboard Power LED
An Onb oard Powe r LED is lo cated at D P1 on
the motherboard. When this LED is on, the
system power is on. Be sure to turn off the
system and unplug the power cord before
removing or installing components. See the
tables at r ight fo r more info rmati on.
BMC Activity LED
A BMC Heartbeat LED is located at D33 on the
motherboard. When D33 is on, BMC (Baseboard M anageme nt Control ler) is acti ve. See
the tabl es at rig ht for mor e infor mation.
Onboard PWR LED
Indicator Settings
LED Color Defi nition
OffSystem Off (PWR
cable not connected)
GreenSystem On
Green:
ACPI S1 State
Flashing
BMC Activity LED Indicator
LED Settings
Green: BlinkingBMC is active
KB/MOUSE
USB2/3/4/5
CD1
JL2
B
VGA
USB0/1
LAN2
J138
Audio CTRL
ALC888
IPMI
Firmware
1
D33
FAN6
COM1
AUDIO FP
CD-IN
JAUDIO1
LAN CTRL
JPAC
WPCM450
BMC CTRL
Memory
for IPMI
COM2
FAN5
IPMI_LAN
LAN1
82574
LAN CTRL
82574
JPUSB1
PHY
FAN8/CPU2
CPU
VRM
JPL2
Slot11 PCI-E 2.0 x4(in x8 Slot)
Slot10 PCI-E 2.0 x16
JPL1
Slot8 PCI-E 2.0 x16
JI2C2
JI2C1
JPG1
Slot6 PCI-E 2.0 x16
Slot5 PCI 33MHz
Slot4 PCI-E 2.0 x16
Slot3 PCI 33MHz
Slot2 PCI-E 2.0 x4(in x16 Slot)
Slot1 PCI-E x4(in x16 Slot)
P2-DIMM3A
P2-DIMM3B
P2-DIMM2A
P2-DIMM2B
P2-DIMM1A
P2-DIMM1B
ALWAYS POPULATE DIMM A FIRST
CPU2
X8DTG-QF
Rev. 2.0
1
JSMB1
JWOL
JWD
PWR I2C
FAN7/CPU1
JPI2C
ALWAYS POPULATE DIMM A FIRST
Intel 5520
IOH-36D
JBT1
BIOS
JP3
JP6
Intel
ICH 10R
J18
TPM
JTPM1
FAN9
JPW2
T-SGPIO1
P1-DIMM1B
P1-DIMM1A
P1-DIMM2B
P1-DIMM2A
P1-DIMM3B
P1-DIMM3A
Intel 5520
IOH-36D
CPU1
T-SGPIO2
JPW1
JPW3
FAN1
FAN2
JD1
FAN3
FAN10
SP1
A
DP1
FP CTRL
JF1
JOH1
USB7
USB6
Battery
JPUSB2
USB8/9
FAN4
I-SATA4
I-SATA5
JL1
I-SATA0
I-SATA2
I-SATA1
I-SATA3
A. DP1
B. LE2
2-35
Page 56
X8DTG-QF User's Manual
F
E
D
2-9 Serial ATA Connections
Serial ATA Ports
Six Ser ial ATA Por ts (I -S ATA0 ~ I- SATA 5) are
located below the onboard battery on the
motherboard. These ports, supported by Intel
ICH10R (South Bridge), provide serial-link
signal transmission, which is faster than that
of the traditional Parallel ATA . See the table
on the r ight for p in defi nitions.
A. I-SATA0
B. I-SATA1
C. I-SATA2
D. I-SATA3
E. I-SATA4
F. I-SATA5
2-36
Page 57
Chapter 3: Troubleshooting
Chapter 3
Troubleshooting
3-1 Troubleshooting Procedures
Use the following procedures to troubleshoot your system. If you have followed all
of the procedures below and still need assistance, refer to the ‘Technical Support
Procedures’ and/or ‘Returning Merchandise for Service’ section(s) in this chapter.
Note: Always disconnect the power cord before adding, changing or installing any
hardware components.
Before Power On
Make sure that there are no short circuits between the motherboard and 1.
chassis.
Disconnect all ribbon/wire cables from the motherboard, including those for 2.
the keyboard and mouse.
Remove all add-on cards.3.
Install CPU 1 fi rst (making sure it is fully seated) and connect the chassis 4.
speaker and the power LED to the motherboard. (Check all jumper settings
as well.)
No Power
Make sure that no short circuits between the motherboard and the chassis.1.
Make sure that all jumpers are set to their default positions.2.
Check that the 115V/230V switch on the power supply is properly set.3.
Turn the power switch on and off to test the system.4.
The battery on your motherboard may be old. Check to verify that it still sup-5.
plies ~3VDC. If it does not, replace it with a new one.
3-1
Page 58
X8DTG-QF User's Manual
No Video
If the power is on but you have no video, remove all the add-on cards and 1.
cables.
Use the speaker to determine if any beep codes exist. Refer to the Appendix 2.
for details on beep codes.
Losing the System’s Setup Confi guration
Make sure that you are using a high quality power supply. A poor quality 1.
power supply may cause the system to lose the CMOS setup information.
Refer to Section 1-7 for details on recommended power supplies.
The battery on your motherboard may be old. Check to verify that it still sup-2.
plies ~3VDC. If it does not, replace it with a new one.
If the above steps do not fi x the Setup Confi guration problem, contact your 3.
vendor for repairs.
Memory Errors
When a No_Memory_Beep_Code is issued by the system, check the following:
Make sure that the DIMM modules are properly and fully installed. 1.
Check if different speeds of DIMMs have been installed. It is strongly recom-2.
mended to use the same RAM speed for all DIMMs in the system.
Make sure you are using the correct type of DDR3 Registered ECC or Unbuf-3.
fered ECC/Non-ECC 1333 MHz/1066 MHz/800 MHz SDRAM (recommended
by the manufacturer.)
Check for bad DIMM modules or slots by swapping a single module between 4.
all memory slots and check the results.
Make sure that all memory modules are fully seated in their slots. Make sure 5.
to follow the instructions given in Section 2-4 in Chapter 2.
Check the position of the 115V/230V switch on the power supply. 6.
Please follow the instructions given in the DIMM Population Tables listed in 7.
Section 2-4 in Chapter 2 to install your memory modules.
3-2
Page 59
Chapter 3: Troubleshooting
3-2 Technical Support Procedures
Before contacting Technical Support, please take the following steps. Also, please
note that as a motherboard manufacturer, Supermicro does not sell directly to endusers, so it is best to fi rst check with your distributor or reseller for troubleshooting
services. They should know of any possible problem(s) with the specifi c system
confi guration that was sold to you.
Please go through the ‘Troubleshooting Procedures’ and 'Frequently Asked 1.
Question' (FAQ) sections in this chapter or see the FAQs on our web site
(
http://www.supermicro.com/support/faqs/) before contacting Technical Sup-
port.
BIOS upgrades can be downloaded from our web site at 2.
supermicro.com/support/bios/
If you still cannot resolve the problem, include the following information when 3.
contacting Supermicro for technical support:
Motherboard model and PCB revision number
•
BIOS release date/version (this can be seen on the initial display when your •
system fi rst boots up)
System confi guration
•
An example of a Technical Support form is on our web site at • (http://www.
supermicro.com/support/contact.cfm).
Distributors: For immediate assistance, please have your account number ready
•
when placing a call to our technical support department. We can be reached by
e-mail at support@supermicro.com or by fax at: (408) 503-8000, option 2.
).
(http://www.
3-3 Frequently Asked Questions
Que sti on: Wh at a re th e var iou s t ype s of m emo r y th at my mo th er boa rd c an
support?
Answer: The X8DTG-QF has 12 240-pin DIMM slots that support Registered ECC
or Unbuffered ECC/Non-ECC DDR3 1333/1066/800 MHz Memory. See Section 2-4
in Chapter 2 for DIMM Slot Population.
3-3
Page 60
X8DTG-QF User's Manual
Que stio n: How do I u pda te my BI OS?
Answer: It is recommended that you do not upgrade your BIOS if you are not
experiencing any problems with your system. Updated BIOS fi les are located on
our web site at
warning message and the information on how to update your BIOS on our web
site. Select your motherboard model and download the BIOS fi le to your computer.
Also, check the current BIOS revision and make sure that it is newer than your
BIOS before downloading. You can choose from the zip fi le and the .exe fi le. If you
choose the zip BIOS fi le, please unzip the BIOS fi le onto a bootable USB device.
Run the batch fi le using the format fl ash.bat fi lename.rom from your bootable USB
device to fl ash the BIOS. Then, your system will automatically reboot. Please note
that this process may take a few minutes to complete. Do not be concerned if the
screen is paused for a few minutes.
Warning: Do not s hut down or re set the syste m while up dating the B IOS
to prevent possible system boot failure!)
Note: The SPI BIO S chip used on thi s motherboa rd cannot be rem oved.
Send your motherboard back to our RMA Department at Supermicro for
repair.
Question: What's on the CD that came with my motherboard?
Answer: The supplied compact disc has quite a few drivers and programs that will
greatl y enhanc e your sys tem. We rec omme nd that you r eview th e CD and in stall
the appl icat ions you n eed. Ap plic ation s on the C D inclu de chip set dri vers fo r the
Window s OS, sec uri ty and a udio dr ivers.
3-4 Returning Merchandise for Service
A receipt or copy of your invoice marked with the date of purchase is required before any warranty service will be rendered. You can obtain service by calling your
vendor for a Returned Merchandise Authorization (RMA) number. When returning to
the manufacturer, the RMA number should be prominently displayed on the outside
of the shipping carton, and mailed prepaid or hand-carried. Shipping and handling
charges will be applied for all orders that must be mailed when service is complete.
For faster service, You can also request a RMA authorization online (http://www.
supermicro.com/support/rma/).
This warranty only covers normal consumer use and does not cover damages incurred in shipping or from failure due to the alternation, misuse, abuse or improper
maintenance of products.
During the warranty period, contact your distributor fi rst for any product problems.
3-4
Page 61
Chapter 4: AMI BIOS
Chapter 4
BIOS
4-1 Introduction
This chapter describes the AMI BIOS Setup Utility for the X8DTG-QF. The AMI
ROM BIOS is stored in a Flash EEPROM and can be easily updated. This chapter
describes the basic navigation of the AMI BIOS Setup Utility setup screens.
Starting BIOS Setup Utility
To enter the AMI BIOS Setup Utility screens, press the <Delete> key while the
system is booting up.
Note: In most cases, the <Delete> key is used to invoke the AMI BIOS
setup screen. There are a few cases when other keys are used, such as
<F1>, <F2>, etc.
Each main BIOS menu option is described in this manual. The Main BIOS setup
menu screen has two main frames. The left frame displays all the options that can
be confi gured. Grayed-out options cannot be confi gured. Options in blue can be con-fi gured by the user. The right frame displays the key legend. Above the key legend is
an area reserved for a text message. When an option is selected in the left frame, it
is highlighted in white. Often a text message will accompany it. The AMI BIOS Setup
Utility uses a key-based navigation system called "hot keys". Most of the AMI BIOS
setup utility "hot keys" can be used at any time during the setup navigation process.
These keys include <F1>, <F10>, <Enter>, <ESC>, arrow keys, etc.
Note 1: Options printed in Bold are default settings.
Note 2: the AMI BIOS has default text messages built in. Supermicro re-
tains the option to include, omit, or change any of these text messages.)
How To Change the Confi guration Data
The confi guration data that determines the system parameters may be changed by
entering the AMI BIOS Setup utility. This Setup utility can be accessed by pressing
<Del> at the appropriate time during system boot.
Starting the Setup Utility
Normally, the only visible Power-On Self-Test (POST) routine is the memory test.
As the memory is being tested, press the <Delete> key to enter the main menu of
4-1
Page 62
X8DTG-QFUser’s Manual
the AMI BIOS Setup Utility. From the main menu, you can access the other setup
screens. An AMI BIOS identifi cation string is displayed at the left bottom corner of
the screen below the copyright message.
Warning! Do not upgrade the BIOS unless your system has a BIOS-related
issue. Flashing the wrong BIOS can cause irreparable damage to the
system. In no event shall Supermicro be liable for direct, indirect, special,
incidental, or consequential damages arising from a BIOS update. If you
have to update the BIOS, do not shut down or reset the system while the
BIOS is updating. This is to avoid possible boot failure.
4-2 Main Setup
When you fi rst enter the AMI BIOS Setup Utility , you will enter the Main setup screen.
You can always return to the Main setup screen by selecting the Main tab on the
top of the screen. The Main BIOS Setup screen is shown below.
System Overview: The following BIOS information will be displayed:
System Time/System Date
Use this option to change the system time and date. Highlight System Time or System Date using the arrow keys. Enter new values through the keyboard and press
<Enter>. Press the <Tab> key to move between fi elds. The date must be entered
in MM/DD/YY format. The time is entered in HH:MM:SS format. (Note: The time is
in the 24-hour format. For example, 5:30 P.M. appears as 17:30:00.)
4-2
Page 63
Chapter 4: AMI BIOS
Supermicro X8DTG-QF
Version: This item displays the BIOS revision used in your system.
•
Build Date: This item displays the date when this BIOS was completed.•
Processor
The AMI BIOS will automatically display the status of the processor used in your
system:
CPU Type: This item displays the type of CPU used in the motherboard.
•
Speed: This item displays the speed of the CPU detected by the BIOS.•
Physical Count: This item displays the number of processors installed in your •
system as detected by the BIOS.
Logical Count: This item displays the number of CPU Cores installed in your
•
system as detected by the BIOS.
System Memory
This displays the size of memory available in the system.
4-3
Page 64
X8DTG-QFUser’s Manual
4-3 Advanced Setup Confi gurations
Use the arrow keys to select the Boot Setup submenu, and press <Enter> to access the following items:
Boot Features
Quick Boot
If Enabled, this option will skip certain tests during POST to reduce the time needed
for system boot. The options are Enabled and Disabled.
Quiet Boot
This option allows the bootup screen options to be modifi ed between POST mes-
sages or the OEM logo. Select Disabled to display the POST messages. Select
Enabled to display the OEM logo instead of the normal POST messages. The options are Enabled and Disabled.
AddOn ROM Display Mode
This sets the display mode for the Option ROM. Select Keep Current to use the current AddOn ROM Display setting. Select Force BIOS to use the Option ROM display
mode set by the system BIOS. The options are Force BIOS and Keep Current.
Bootup Num-Lock
This feature allows the user to select the Power-on state for the Numlock key. The
option s are Of f an d On.
Wait For 'F1' If Error
This for ce s the sys tem to wai t until t he ' F1' key is pressed i f an er ror o cc urs . The
option s are Dis able d and Enabled.
4-4
Page 65
Chapter 4: AMI BIOS
Hit 'Del' Message Display
This feature displays "Press DEL to run Setup" during POST. The options are
Enabled and Disabled.
Interrupt 19 Capture
Interrupt 19 is the software interrupt that handles the boot disk function. When this
item is set to Enabled, the ROM BIOS of the host adaptors will "capture" Interrupt 19
at bootup and allow the drives that are attached to these host adaptors to function
as bootable disks. If this item is set to Disabled, the ROM BIOS of the host adaptors will not capture Interrupt 19, and the drives attached to these adaptors will not
function as bootable devices. The options are Enabled and Disabled.
Power Confi guration
Watch Dog Function
If enable d, the Watch Do g Timer wil l a l l o w the system to reboot when i t i s i n a ctive
for more t han 5 minu tes. The o ption s are Enabl ed and Disabled.
Power Button Function
If set to Instant_Off, the system will power off immediately as soon as the user hits
the power button. If set to 4_Second_Override, the system will power off when the
user presses the power button for 4 seconds or longer. The options are Instant_Off
and 4_Second_Override.
Restore on AC Power Loss
Use this feature to set the power state after a power outage. Select Power-Off for
the system power to remain off after a power loss. Select Power-On for the system
power to be turned on after a power loss. Select Last State to allow the system to
resume its last state before a power loss. The options are Power-On, Power-Off
and Last State.
EUP Support
Selec t Enabled to sup ply standby po wer to the system w hile in S5 state t o fulfi ll
the EUP requirements. Select Disabled to use the "wake-up" feature while the
system is in S 5 state. Th e optio ns are Enab led and Disabled.
Processor and Clock Options
This submenu allows the user to confi gure the Processor and Clock settings.
4-5
Page 66
X8DTG-QFUser’s Manual
Clock Spread Spectrum
Select Enable to use the feature of Clock Spectrum, which will allow the BIOS to
monitor and attempt to reduce the level of Electromagnetic Interference caused by
the components whenever needed. The options are Disabled and Enabled.
Hardware Prefetcher (Available when supported by the CPU)
If set to Enabled, the hardware pre fetcher will pre fetch streams of data and instructions from the main memory to the L2 cache in the forward or backward manner to
improve CPU performance. The options are Disabled and Enabled.
Adjacent Cache Line Prefetch (Available when supported by the CPU)
The CPU fetches the cache line for 64 bytes if this option is set to Disabled. The
CPU fetches both cache lines for 128 bytes as comprised if Enabled.
MPS and ACPI MADT Ordering
This feature allows you to choose the method of ordering for the Multiple APIC
Description Table (MADT). Select Modern Ordering for Microsoft Windows XP or
later, Select Legacy Ordering for Microsoft Windows 2000 or earlier. The options
are Modern Ordering and Legacy Ordering.
Intel® Virtualization Technology (Available when supported by the CPU)
Select Enabled to use the feature of Virtualization Technology to allow one platform
to run multiple operating systems and applications in independent partitions, creating mult iple "v irtu al" system s in one physi cal co mputer. The opti ons are Enable d
and Disabled.
Note: If there is any change to this setting, you will need to power off and
restart the system for the change to take effect. Please refer to Intel’s web
site for detailed information.
Execute-Disable Bit Capability (Available when supported by the OS and the
CPU)
Set to Enabled to enable the Execute Disable Bit which will allow the processor
to designate areas in the system memory where an application code can execute
and where it cannot, thus preventing a worm or a virus from fl ooding illegal codes
to overwhelm the processor or damage the system during an attack. The default is
Enabled. (Refer to Intel and Microsoft Web Sites for more information.)
Simultaneous Multi-Threading (Available when supported by the CPU)
Set to Enabled to use the Simultaneous Multi-Threading Technology, which will result
in increased CPU performance. The options are Disabled and Enabled.
4-6
Page 67
Chapter 4: AMI BIOS
Active Processor Cores
Set to Enabled to use a processor's Second Core and beyond. (Please refer to
Intel's web site for more information.) The options are All, 1 and 2.
Intel® EIST Technology
EIST (Enhanced Intel SpeedStep Technology) allows the system to automatically
adjust processor voltage and core frequency in an effort to reduce power consumption and heat dissipation. Please refer to Intel’s web site for detailed information.
The options are Disable (Disable GV3) and Enable (Enable GV3).
Intel® TurboMode Tech.
Select Enabled to allow the processor cores to run faster than normal under special
circumstances to improve performance. The options are Disable and Enabled.
C1E Support
Select Enabled to use the feature of Enhanced Halt State. C1E signifi cantly reduces
the CPU's power consumption by reducing the CPU's clock cycle and voltage during
a Halt State. The options are Disabled and Enabled.
Intel® C-State Tech
If enabled, C-State is set by the system automatically to either C2, C3 or C4 state.
The options are Disabled and Enabled.
C-State package limit setting (Available when Intel® C-State Tech is
enabled)
If set to Auto, the AMI BIOS will automatically set the limit on the C-State package
register. The options are Auto, C1, C3, C6 and C7.
C1 Auto Demotion
When enabled, the CPU will conditionally demote C3, C6 or C7 requests to C1 based
on un-core auto-demote information. The options are Disabled and Enabled.
C3 Auto Demotion
When enabled, the CPU will conditionally demote C6 or C7 requests to C3 based
on un-core auto-demote information. The options are Disabled and Enabled.
ACPI T State
Select Enabled to report processor throttling in ACPI. The options are Disabled
and Enabled.
4-7
Page 68
X8DTG-QFUser’s Manual
Advanced Chipset Control
The items included in the Advanced Settings submenu are listed below:
CPU Bridge Confi guration
QPI Links Speed
This feature selects QPI's data transfer speed. The options are Slow-mode, and
Full Speed.
QPI Frequency (Available when QPI Links Speed is set to 'Full Speed')
This selects the desired QPI frequency. The options are Auto, 4.800 GT,
5.866GT, 6.400 GT.
QPI L0s and L1
This enables the QPI power state to low power. L0s and L1 are automatically
selected by the motherboard. The options are Disabled and Enabled.
Memory Frequency
This feature forces a DDR3 frequency slower than what the system has detected
to run at the frequency as specifi ed. The available options are Auto, Force DDR-
800, Force DDR-1066, Force DDR-1333 and Force SPD.
Memory Mode
The options are Independent, Channel Mirroring, and Lockstep.
Independent - All DIMMs are available to the operating system.
Channel Mirroring - The motherboard maintains two identical copies of all data
in memory for redundancy.
Lockstep - The motherboard uses two areas of memory to run the same set of
operations in parallel.
Demand Scrubbing
This is a memory error-correction scheme that allows the processor to write corrected data back into the memory block from where it was read by the Processor.
The options are Enabled and Disabled.
Patrol Scrubbing
This is a memory error-correction scheme that works in the background looking
for and correcting resident errors. The options are Enabled and Disabled.
4-8
Page 69
Chapter 4: AMI BIOS
Throttling - Closed Loop
Throttling improves reliability and reduces power in the processor by automatic
voltage control during processor idle states. Available options are Disabled and
Enabled.
North Bridge Confi guration
This feature allows the user to confi gure the settings for the Intel North Bridge.
Intel I/O AT
This feature works with the Intel I/O AT (Acceleration Technology) to accelerate
the performance of TOE devices. (Note: A TOE device is a specialized, dedicated
processor that is installed on an add-on card or a network card to handle some
or all packet processing of this add-on card.) When this feature is set to Enabled,
it will enhance overall system performance by providing direct memory access for
data transferring. The options are Enabled and Disabled.
DCA (Direct Cache Access) Technology (Available when Intel I/O AT is
enabled)
This feature works in conjunction with the Intel I/O AT (Acceleration Technology) to
accelerate the performance of the TOE device. When this feature set to Enabled, it
will enhance overall system performance by providing direct cache access for data
transferring. The options are Enabled and Disabled.
DCA Prefetch Delay
A DCA Prefetch is used with TOE components to prefetch data in order to shorten
execution cycles and maximize data processing effi ciency. Prefetching too fre-
quently can saturate the cache directory and delay necessary cache accesses. This
feature reduces or increases the frequency the system prefetches data. The options
are [8], [16], [24], [32], [40], [48], [56], [64], [72], [80], [88], [96], [104], [112], [120]
Intel VT-d
Select Enabled to enable Intel's Virtualization Technology support for Direct I/O VT-d
by reporting the I/O device assignments to VMM through the DMAR ACPI Tables.
This feature offers fully-protected I/O resource-sharing across the Intel platforms,
providing the user with greater reliability, security and availability in networking and
data-sharing. The settings are Enabled and Disabled.
Active State Power Management
Selec t Enabled to star t Active -State Powe r Management fo r signal trans actions
betwe en L0 an d L1 Links on the PCI E xp re s s Bus . Th is ma x im ize s powe r-s avin g
and tran sact ion spe ed. The o ption s are Enabl ed and Disabled.
4-9
Page 70
X8DTG-QFUser’s Manual
IOH PCIE Max Payload Size
Some add-on cards perform faster with the coalesce feature, which limits the
payload size to 128B; while others, with a payload size of 256B which inhibits the
coalesce feature. Please refer to your add-on card user guide for the desired setting. The options are 256B and 128MB.
South Bridge Confi guration
This feature allows the user to confi gure the settings for the Intel South Bridge.
USB Functions
This feature allows the user to decide the number of onboard USB ports to be
enabled. The Options are: Disabled, and Enabled. (If this item is set to Enabled,
USB 2.0 Controller will be enabled.)
Legacy USB Support
Select Enabled to use Legacy USB devices. If this item is set to Auto, Legacy USB
support will be automatically enabled if a legacy USB device is installed on the
motherboard, and vise versa. The settings are Disabled, Enabled and Auto.
USB 2.0 Controller
Select Enabled to activate USB 2.0 Controller. The options are Enabled and Disabled. (Note: If the item - USB Functions is enabled, USB 2.0 Controller will always
be enabled. When the item - USB Functions is set to Disabled, the user has the
option to enable or disable USB 2.0 Controller.)
USB 2.0 Controller Mode
This setting allows you to select the USB 2.0 Controller mode. The options are
Hi-Speed (480 Mbps) and Full Speed (12 Mbps).
BIOS EHCI Hand-Off
Select Enabled to enable BIOS Enhanced Host Controller Interface support to
provide a workaround solution for an operating system that does not have EHCI
Hand-Off support. When enabled, the EHCI Interface will be changed from the BIOScontrolled to the OS-controlled. The options are Disabled and Enabled.
HDA Controller
Select Enabled to activate the onboard High-Defi nition Audio controller. The options
are Enabled and Disabled.
Frontside Audio Mode
Select HD Audio to enable high-defi nition audio support for frontside audio. Select
AC'97 to use AC'97 for frontside audio. The options are HD Audio and AC'97.
4-10
Page 71
Chapter 4: AMI BIOS
Route Port 80h Cycle to
Use this item to decide where to route Port 80h Cycle to. The Options are LPC
and PCI.
IDE/SATA/Floppy Confi guration
When this submenu is selected, the AMI BIOS automatically detects the presence
of the IDE devices and displays the following items:
SATA#1 Confi guration
If Compatible is selected, it sets SATA#1 to legacy compatibility mode, while selecting Enhanced sets SATA#1 to native SATA mode. The options are Disabled,
Compatible and Enhanced.
Confi gure SATA#1 as (Not available when SATA#1 Confi guration is
disabled)
This feature allows the user to select the drive type for SATA#1. The options are
IDE, RAID and AHCI. (When the option-RAID is selected, the item-ICH RAID
Code Base will appear. When the option-AHCI is selected, the item-ICH AHCI
Codebase will be available.)
ICH RAID Code Base (Available when the option-RAID is selected.)
Select Intel to enable Intel's SATA RAID fi rmware to confi gure Intel's SATA
RAID settings. Select Adaptec to enable Adaptec's SATA RAID fi rmware
to confi gure Adaptec's SATA RAID settings. The options are Intel and
Adaptec.
ICH AHCI Codebase (Available when the option-AHCI is selected.)
Use this feature to select the AHCI Codebase for the ICH South Bridge. The
options are BIOS Native Module and Intel AHCI ROM.
SATA#2 Confi guration (This feature is available when the option-IDE is
selected)
Selecting Enhanced will set SA T A#2 to native SA TA mode. The options are Disabled,
and Enhanced.
IDE Detect Timeout (sec)
Use this item to set the time-out value for the BIOS to detect the ATA, ATAPI devices
installed in the system. The options are 0 (sec), 5, 10, 15, 20, 25, 30, and 35.
4-11
Page 72
X8DTG-QFUser’s Manual
Primary IDE Master/Slave, Secondary IDE Master/Slave, Third IDE Master,
and Fourth IDE Master
These settings allow the user to set the parameters of the IDE slots as specifi ed.
Press <Enter> to activate the following submenu items. Set the correct confi gura-
tions accordingly.
Type
This feature allows the user to select the type of device connected to the slot.
Select Auto to allow the BIOS to automatically select the device type as it is
detected on the slot. Select CD/DVD to confi gure the slot for CD/DVD devices.
Select ARMD to use this slot for removable devices. The options are Not Installed, Auto, CD/DVD and ARMD.
LBA/Large Mode
LBA (Logical Block Addressing) is a method of addressing data on a disk drive.
In the LBA mode, the maximum drive capacity is 137 GB. For drive capacities
over 137 GB, your system must be equipped with a 48-bit LBA mode addressing.
If not, contact your manufacturer or install an ATA/133 IDE controller card that
supports 48-bit LBA mode. The options are Disabled and Auto.
Block (Multi-Sector Transfer)
Block Mode boosts the IDE drive performance by increasing the amount of data
transferred. Only 512 bytes of data can be transferred per interrupt if Block Mode
is not used. Block Mode allows transfers of up to 64 KB per interrupt. Select
Disabled to allow data to be transferred from and to the device one sector at a
time. Select Auto to allow data transfer from and to the device occur multiple
sectors at a time if the device supports it. The options are Auto and Disabled.
PIO Mode
The IDE PIO (Programmable I/O) Mode programs timing cycles between the
IDE drive and the programmable IDE controller. As the PIO mode increases, the
cycle time decreases. The options are Auto, 0, 1, 2, 3, and 4.
Select Auto to allow the AMI BIOS to automatically detect the PIO mode. Use
this value if the IDE disk drive support cannot be determined.
Select 0 to allow the AMI BIOS to use PIO mode 0. It has a data transfer rate
of 3.3 MB/s.
Select 1 to allow the AMI BIOS to use PIO mode 1. It has a data transfer rate
of 5.2 MB/s.
Select 2 to allow the AMI BIOS to use PIO mode 2. It has a data transfer rate
of 8.3 MB/s.
4-12
Page 73
Chapter 4: AMI BIOS
Select 3 to allow the AMI BIOS to use PIO mode 3. It has a data transfer rate
of 11.1 MB/s.
Select 4 to allow the AMI BIOS to use PIO mode 4. It has a data transfer bandwidth of 32-Bits. Select Enabled to enable 32-Bit data transfer.
DMA Mode
Select Auto to allow the BIOS to automatically detect IDE DMA mode when the
IDE disk drive support cannot be determined.
Select SWDMA0 to allow the BIOS to use Single Word DMA mode 0. It has a
data transfer rate of 2.1 MB/s.
Select SWDMA1 to allow the BIOS to use Single Word DMA mode 1. It has a
data transfer rate of 4.2 MB/s.
Select SWDMA2 to allow the BIOS to use Single Word DMA mode 2. It has a
data transfer rate of 8.3 MB/s.
Select MWDMA0 to allow the BIOS to use Multi Word DMA mode 0. It has a
data transfer rate of 4.2 MB/s.
Select MWDMA1 to allow the BIOS to use Multi Word DMA mode 1. It has a
data transfer rate of 13.3 MB/s.
Select MWDMA2 to allow the BIOS to use Multi-Word DMA mode 2. It has a
data transfer rate of 16.6 MB/s.
Select UDMA0 to allow the BIOS to use Ultra DMA mode 0. It has a data transfer
rate of 16.6 MB/s. It has the same transfer rate as PIO mode 4 and Multi Word
DMA mode 2.
Select UDMA1 to allow the BIOS to use Ultra DMA mode 1. It has a data transfer
rate of 25 MB/s.
Select UDMA2 to allow the BIOS to use Ultra DMA mode 2. It has a data transfer
rate of 33.3 MB/s.
Select UDMA3 to allow the BIOS to use Ultra DMA mode 3. It has a data transfer
rate of 44.4 MB/s.
Select UDMA4 to allow the BIOS to use Ultra DMA mode 4. It has a data transfer
rate of 66.6 MB/s.
Select UDMA5 to allow the BIOS to use Ultra DMA mode 5. It has a data transfer
rate of 100 MB/s.
Select UDMA6 to allow the BIOS to use Ultra DMA mode 6. It has a data transfer
rate of 133 MB/s. The options are Auto, SWDMAn, MWDMAn, and UDMAn.
S.M.A.R.T. For Hard disk drives
Self-Monitoring Analysis and Reporting Technology (SMART) can help predict
impending drive failures. Select Auto to allow the AMI BIOS to automatically de-
4-13
Page 74
X8DTG-QFUser’s Manual
tect hard disk drive support. Select Disabled to prevent the AMI BIOS from using
the S.M.A.R.T. Select Enabled to allow the AMI BIOS to use the S.M.A.R.T. to
support hard drive disk. The options are Disabled, Enabled, and Auto.
32Bit Data Transfer
Select Enable to enable 32-bit IDE data transferring support. The options are
Enabled and Disabled.
PCI/PnP Confi guration
Clear NVRAM
This feature clears the NVRAM during system boot. The options are No and Yes.
Plug & Play OS
Selecting Yes allows the OS to confi gure Plug & Play devices. (This is not required
for system boot if your system has an OS that supports Plug & Play.) Select No to
allow the AMI BIOS to confi gure all devices in the system.
PCI Latency Timer
This feature sets the latency Timer of each PCI device installed on a PCI bus. Select
64 to set the PCI latency to 64 PCI clock cycles. The options are 32, 64, 96, 128,
160, 192, 224 and 248.
PCI IDE BusMaster
When enabled, the BIOS uses PCI bus mastering for reading/writing to IDE drives.
The options are Disabled and Enabled.
SR-IOV Support
Single Root I/O Virtualization is an industry-standard mechanism that allow devices
to advertise their capability to be simultaneously shared among several virtual
machines. SR-IOV is capable of partitioning a PCI function into several virtual
interfaces for sharing the resources of a PCI Express device under a virtual environment. The options are Disabled and Enabled.
Use this setting to enable or disable any of the PCI slots indicated above. The options are Disabled and Enabled.
Onboard LAN Option ROM 1 Select
The item selects the type of onboard option ROM to load. The options are PXE
and iSCSI.
4-14
Page 75
Chapter 4: AMI BIOS
Load Onboard LAN 1 Option ROM/Load Onboard LAN 2 Option ROM
Selec t Enabled to ena ble onboard L AN1/LA N2 Optio n ROMs suppo rt whic h will
allow you to boot your systems using a network interface. The options are Enabled
and Disabled.
Boot Graphics Adapter Priority
This feature allows the user to specify which graphics controller to be used as
the pri mary b oot graphic s contr oller. The options are Onboard VGA, Slot 6 and
Offboard VGA.
Super IO Device Confi guration
Serial Port1 Address/IRQ, Serial Port2 Address/IRQ
This option specifi es the base I/O port address and the Interrupt Request address
of Serial Port 1 and Serial Port 2. Select Disabled to prevent the serial port from
accessing any system resources. When this option is set to Disabled, the serial port
physically becomes unavailable. Select 3F8/IRQ4 to allow the serial port to use 3F8
as its I/O port address and IRQ 4 for the interrupt address. The options for Serial
Port1 are Disabled, 3F8/IRQ4, 3E8/IRQ4, 2E8/IRQ3 and 2F8/IRQ3. The options for
Serial Port2 are Disabled, 2F8/IRQ3, 3E8/IRQ4, 3F8/IRQ4, and 2E8/IRQ3.
Serial Port 2 Attribute
This feature enables COM2 to act as a virtual COM Port for Serial Over LAN (SOL).
The options are COM and SOL.
Remote Access Confi guration
Remote Access
This allows the user to enable Remote Access support. The options are Disabled
and Enabled. If Remote Access is set to Enabled, the following items will display:
Serial Port Number
This feature allows the user decide which serial port to be used for Console
Redirection. The options are COM 1 and COM2.
Base Address, IRQ
This item displays the base address and IRQ of the serial port used for
Console Redirection. This setting is confi gured via the item-Serial Port 1
Address/IRQ or Serial Port 2 Address/IRQ in the Super I/O submenu.
4-15
Page 76
X8DTG-QFUser’s Manual
Serial Port Mode
This feature allows the user to set the serial port mode for Console Redirection.
The options are 115200 8, n 1; 57600 8, n, 1; 38400 8, n, 1; 19200 8, n, 1; and
9600 8, n, 1.
Flow Control
This feature allows the user to set the fl ow control for Console Redirection. The
options are None, Hardware, and Software.
Redirection After BIOS POST
Select Disabled to turn off Console Redirection after Power-On Self-Test
(POST). Select A lways to keep Console Redirection ac tive all the time af ter
POST. (Note: This settin g may not be sup por ted by so me oper ating sys tems.)
Select Boot Loader to keep Console Redirection active during POST and Boot
Loader. The opti ons are D isabl ed, Boot L oader, and Always.
Terminal Type
This feature allows the user to select the target terminal type for Console Redirection. The options are ANSI, VT100, and VT-UTF8.
VT-UTF8 Combo Key Support
Select Enabled to enable VT-UTF8 Combination Key support for ANSI/VT100
terminals. The options are Enabled and Disabled.
Sredir Memory Display Delay
This feature defi nes the length of time in seconds to display memory information.
The options are No Delay, Delay 1 Sec, Delay 2 Sec, and Delay 4 Sec.
Hardware Health Confi guration
This feature allows the user to monitor system health and review the status of each
item as displayed.
CPU Overheat Alarm
This option allows the user to select the CPU Overheat Alarm setting which determines when the CPU OH alarm will be activated to provide warning of possible
CPU overheat.
Warning!
1. Any temperature that exceeds the CPU threshold temperature pre-
defi ned by the CPU manufacturer may result in CPU overheat or system
instability. When the CPU temperature reaches this predefi ned threshold,
the CPU and system cooling fans will run at full speed.
4-16
Page 77
Chapter 4: AMI BIOS
2. To avoid possible system overheating, please be sure to provide adequate airfl ow to your system.
The options are:
The Early Alarm: Select this setting if you want the CPU overheat alarm (includ-
•
ing the LED and the buzzer) to be triggered as soon as the CPU temperature
reaches the CPU overheat threshold as predefi ned by the CPU manufacturer.
The Default Alarm
• : Select this setting if you want the CPU overheat alarm
(including the LED and the buzzer) to be triggered when the CPU temperature
reaches about 5
manufacturer to give the CPU and system fans additional time needed for CPU
and system cooling. In both the alarms above, please take immediate action
as shown below.
CPU 1 Temperature/CPU 2 Temperature/IOH1 Temperature/IOH2
Temperature/System Temperature
o
C above the threshold temperature as predefi ned by the CPU
This feature displays current temperature readings for the CPU and the System.
The following items will be displayed for your reference only:
CPU 1 Temperature/CPU 2 Temperature
The CPU thermal technology that reports absolute temperatures (Celsius/Fahrenheit) has been upgraded to a more advanced feature by Intel in its newer
processors. The basic concept is each CPU is embedded by unique temperature
information that the motherboard can read. This ‘Temperature Threshold’ or ‘Temperature Tolerance’ has been assigned at the factory and is the baseline on which
the motherboard takes action during different CPU temperature conditions (i.e., by
increasing CPU Fan speed, triggering the Overheat Alarm, etc). Since CPUs can
have different ‘Temperature Tolerances’, the installed CPU can now send information to the motherboard what its ‘Temperature Tolerance’ is, and not the other way
around. This results in better CPU thermal management.
Supermicro has leveraged this feature by assigning a temperature status to certain
thermal conditions in the processor (Low, Medium and High). This makes it easier
for the user to understand the CPU’s temperature status, rather than by just simply
seeing a temperature reading. The CPU Temperature feature will display the CPU
temperature status as detected by the BIOS:
Low – This level is considered as the ‘normal’ operating state. The CPU temperature
is well below the CPU ‘Temperature Tolerance’. The motherboard fans and CPU will
run normally as confi gured in the BIOS (Fan Speed Control).
Medium – The processor is running warmer. This is a ‘precautionary’ level and
generally means that there may be factors contributing to this condition, but the CPU
is still within its normal operating state and below the CPU ‘Temperature Tolerance’.
4-17
Page 78
X8DTG-QFUser’s Manual
The motherboard fans and CPU will run normally as confi gured in the BIOS. The
fans may adjust to a faster speed depending on the Fan Speed Control settings.
User intervention: No action is required. However, consider checking the CPU fans
and the chassis ventilation for blockage.
High – The processor is running hot. This is a ‘caution’ level since the CPU’s ‘Temperature Tolerance’ has been reached (or has been exceeded) and may activate
an overheat alarm.
User intervention: If the system buzzer and Overheat LED has activated, take action
immediately by checking the system fans, chassis ventilation and room temperature
to correct any problems.
Notes: 1. The system may shut down if it continues for a long period to
prevent damage to the CPU.
2. The information provided above is for your reference only. For more
information on thermal management, please refer to Intel’s Web site at
www.Intel.com.
IOH1 Temperature/IOH2 Temperature/System Temperature
The temperature for each sensor indicated will be displayed (in degrees in Celsius
and Fahrenheit) as detected by the BIOS.
Fan1 ~ Fan 10 Reading
This feature displays the fan speed readings from Fan1 through Fan8. (Fan1 is
CPU1 Fan and Fan2 is CPU2 Fan.)
Fan Speed Control Modes
This feature allows the user to decide how the system controls the speeds of the
onboard fans. The CPU temperature and the fan speed are correlative. When the
CPU on-die temperature increases, the fan speed will also increase for effective
system cooling. Select "Full Speed/FS" to allow the onboard fans to run at full
speed for maximum cooling. The FS setting is recommended for special system
confi guration or debugging. Select "Performance/PF" for better system cooling. The
PF setting is recommended for high-power-consuming and high-density systems.
Select "Balanced/BL" for the onboard fans to run at a speed that will balance the
needs between system cooling and power saving. The BL setting is recommended
for regular systems with normal hardware confi gurations. Select "Energy Saving/ES"
for best power effi ciency and maximum quietness. The Options are: Full Speed/FS,
Performance/PF, Balanced/BL, and Energy Saving/ES.
Use this feature to confi gure Advanced Confi guration and Power Interface (ACPI)
power management settings for your system.
High Precision Event Timer
Select Enabled to activate the High Performance Event Timer (HPET) that produces
periodic interrupts at a much higher frequency than a Real-time Clock (RTC) does in
synchronizing multimedia streams, providing smooth playback and reducing the dependency on other timestamp calculation devices, such as an x86 RDTSC Instruction embedded in the CPU. The High Performance Event Timer is used to replace
the 8254 Programmable Interval Timer. The options are Enabled and Disabled.
USB Device Wake-Up
Select Enabled for the system to wake up from Standby mode by a Universal Serial Bus (USB) device (such as, a USB mouse or USB keyboard). The options are
Enabled and Disabled.
ACPI Aware O/S
Enable ACPI support if it is supported by the OS to control ACPI through the Operating System. Otherwise, disable this feature. The options are Yes and No.
Suspend Mode (Available ACPI Aware O/S='Yes')
This setting allows you to confi gure the ACPI (Advanced Confi guration and Power
Interface) state for your system when it is in the Suspend mode. The options are
S1 (POS), S3 (STR) and Auto.
ACPI APIC Support (Available ACPI Aware O/S='Yes')
Select Enabled to include the ACPI APIC Table Pointer in the RSDT (Root System
Description Table) pointer list. The options are Enabled and Disabled.
APIC ACPI SCI IRQ
When this item is set to Enabled, APIC ACPI SCI IRQ is supported by the system.
The options are Enabled and Disabled.
Headless Mode (Available ACPI Aware O/S='Yes')
This feature is used to enable system to function without a keyboard, monitor or
mouse attached The options are Enabled and Disabled.
ACPI Version Features (Available ACPI Aware O/S='Yes')
The options are ACPI v1.0, ACPI v2.0 and ACPI v3.0. Please refer to ACPI's website
for further explanation: http://www.acpi.info/.
4-19
Page 80
X8DTG-QFUser’s Manual
NUMA Support
If enabled, Non-Uniform Memory Access will enhance CPU performance. The
options are Enabled, Disabled and NUMA for SLES11 (SUSE Linux Enterprise
Server 11).
Trusted Computing (This option is available for OEM only.)
TCG/TPM Support
Select Yes to enable support for trusted platforms (TPM 1.1/1.2) and allow the BIOS
to automatically download the drivers needed to provide support for the platforms
specifi ed. The options are Yes and No.
Indicate Physical
This feature Enables indication of physical presence to the TPM device each time
the system starts. The options are No and Yes.
TPM Deactivated/Activated
This feature activates or disables the TPM device. The options are Don't Change,
Set and Clear.
TPM Owner
This feature installs or clears TPM ownership The options are Don't Change, En-
able Install, Disable Install and Clear.
Execute TPM Command
This feature Enables or Disables the sending of commands to the TPM. The options
are Don't Change, Enabled and Disabled.
Clear the TPM
Press <Enter> to clear the TPM memory. This will erase all information related to
TPM support.
If TCG/TPM Support is set to Yes, the TPM Status will display:
TPM Enable/Disable Status
TPM Owner Status
IPMI Confi guration
Intelligent Platform Management Interface (IPMI) is a set of common interfaces that
are used for hardware health monitoring and system management. For more information on the IPMI specifi cations, please visit Intel's web site at www.intel.com.
IPMI Firmware Revision
This item displays the IPMI fi rmware revision used in your system.
4-20
Page 81
Chapter 4: AMI BIOS
Status of BMC
Baseboard Management Controller (BMC) manages the interface between system
management software and platform hardware. This is an informational feature which
returns the status code of the BMC micro controller.
View BMC System Event Log
This feat ur e d i sp l ays t h e BMC Sys te m Event Lo g (SE L). It shows the total number
of entries of BMC System Events.
To view an event, select an Entry Number and pressing <Enter> to display the
information as shown in the screen.
SEL Entry Number
•
SEL Record ID•
SEL Record Type•
Event Timestamp•
Generator ID•
Event Message Format Ver•
Event Sensor Type•
Event Sensor Number,•
Event Dir Type•
Event Data.•
Clear BMC System Event Log
Clear BMC System Log
Select OK and press the <Enter> key to clear the BMC system log. Select Cancel
to keep the BMC System log. The options are OK and Cancel.
Caution: Any cleared information is unrecoverable. Make absolutely sure
that you no longer need any data stored in the log before clearing the
BMC Event Log.
4-21
Page 82
X8DTG-QFUser’s Manual
Set LAN Confi guration
Set this feature to confi gure the IPMI LAN adapter with a network address as shown
in the following graphics.
Channel Number - This feature displays the channel number.
Channel Number Status - This feature returns the channel status for the
Channel Number selected above: "Channel Number is OK" or "Wrong Channel
Number".
IP Address Source
This feature allows the user to select the source of the IP address for the system.
If Static is selected, the user will need to manually enter the IP address for the
system. If DHCP is selected, the BIOS will search for a DHCP (Dynamic Host
Confi guration Protocol) server in the network that the system is attached to, and
request the next available IP address. The options are DHCP and Static. If Static
is selected, the following items will be available for confi guration.
IP Address
The BIOS will automatically enter the IP address of this machine; however it
may be over-ridden. This should be in decimal and in dotted quad form (i.e.,
192.168.10.253). The value of each three-digit number separated by dots should
not exceed 255.
Subnet Mask
This item displays the current subnet mask setting for your IPMI connection. The
value of each three-digit number separated by dots should not exceed 255.
Gateway Address
The BIOS will automatically enter the Gateway address of this machine; however
it may be over-ridden. Gateway addresses are 4-decimal numbers in dotted quad
form (i.e., 192.168.10.253). The value of each 3-digit number separated by dots
should not exceed 255.
Mac Address
The BIOS will automatically enter the Mac address of this machine; however it
may be over-ridden. Mac addresses are 6 two-digit hexadecimal numbers (Base
16, 0 ~ 9, A, B, C, D, E, F) separated by dots. (i.e., 00.30.48.D0.D4.60).
Event Log Confi guration
View Event Log
Use this option to view the System Event Log.
4-22
Page 83
Chapter 4: AMI BIOS
Mark all events as read
This option marks all events as read. The options are OK and Cancel.
Clear event log
This option clears the Event Log memory of all messages. The options are OK
and Cancel.
PCIe Error Log
Use this option to enable logging of PCIe Errors. The options are Yes and No.
Memory ECC Error Log
Select Yes to enable ECC memory error logging . The options are Yes and No.
4-4 Security Settings
The AMI BIOS provides a Supervisor and a User password. If you use both passwords, the Supervisor password must be set fi rst.
Supervisor Password
This item indicates if a Supervisor password has been entered for the system. "Not
Installed" means a Supervisor password has not been used.
User Password
This item indicates if a user password has been entered for the system. "Not I nstalle d" means that a u ser password has not been used.
Change Supervisor Password
Select this feature and press <Enter> to access the submenu, and then enter a
new Supervisor Password.
4-23
Page 84
X8DTG-QFUser’s Manual
User Access Level (Available when Supervisor Password is set as above)
Use this feature to set the user's access level. Select Full Access to grant the
user full read and write access to the Setup Utility. Select View Only to allow the
user to view the Setup Utility displays without making any changes. Select Limited
to allow the user to make changes on limited items such as Date and Time, Select
No Access to prevent the user from entering the Setup Utility.
Change User Password
Select this feature and press <Enter> to enter a new User Password.
Clear User Password (Available only if User Password has been set)
This item allows you to clear a user password after it has been entered.
Password Check
Select Setup for the system to check for a password at Setup. Select Always for the
system to check for a password at bootup. The options are Setup and Always.
Boot Sector Virus Protection
When Enabled, the AMI BIOS displays a warning when any program (or virus) issues a Disk Format command or attempts to write to the boot sector of the hard
disk drive. The options are Enabled and Disabled.
4-5 Boot Confi guration
Use this feature to confi gure boot priority settings.
4-24
Page 85
Chapter 4: AMI BIOS
Boot Device Priority
Use this feature to specify the sequence of boot priority for onboard devices. The
settings are 1st boot device~5th boot device and Disabled.
1st Boot Device/2nd Boot Device/3rd Boot Device
•
Hard Disk Drives
Use this feature to specify the boot sequence from all bootable HDD devices. The
settings are Disabled and a list of all hard disk drives that have been detected.
1st Boot Device/2nd Boot Device/3rd Boot Device
•
Removable Drives
Use this feature to specify the boot sequence from available Removable Drives.
The settings are 1st boot device, 2nd boot device, and Disabled.
1st Boot Device/2nd Boot Device/3rd Boot Device
•
CD/DVD Drives
This feature allows the user to specify the boot sequence from available CD/DVD
Drives (i.e., 1st Drive, 2nd Drive, etc).
1st Boot Device/2nd Boot Device/3rd Boot Device
•
Retry Boot Devices
Select Enabled to enable Retry Boot Devices support to allow the system to attempt
to boot from a specifi c boot device after a boot failure. The options are Enabled
and Disabled.
4-25
Page 86
X8DTG-QFUser’s Manual
4-6 Exit Options
Select the Exit tab from the AMI BIOS Setup Utility screen to enter the Exit BIOS
Setup screen.
Save Changes and Exit
When you have completed the system confi guration changes, select this option
to leave the BIOS Setup Utility and reboot the computer, so the new system confi guration parameters can take effect. Select Save Changes and Exit from the Exit
menu and press <Enter>.
Discard Changes and Exit
Select this option to quit the BIOS Setup without making any permanent changes
to the system confi guration, and reboot the computer. Select Discard Changes and
Exit from the Exit menu and press <Enter>.
Discard Changes
Select this option and press <Enter> to discard all the changes and return to the
AMI BIOS Utility Program.
Load Optimal Defaults
To set this feature, select Load Optimal Defaults from the Exit menu and press
<Enter>. Then, select OK to allow the AMI BIOS to automatically load Optimal Defaults to the BIOS Settings. The Optimal settings are designed for maximum system
performance, but may not work best for all computer applications.
Load Fail-Safe Defaults
To set this feature, select Load Fail-Safe Defaults from the Exit menu and press
<Enter>. The Fail-Safe settings are designed for maximum system stability, but not
for maximum performance.
4-26
Page 87
Chapter 4: AMI BIOS
4-7 BIOS Recovery
Warning! Do not upgrade the BIOS unless your system has a BIOS-related
issue. Flashing the wrong BIOS can cause irreparable damage to the
system. In no event shall Supermicro be liable for direct, indirect, special,
incidental, or consequential damages arising from a BIOS update. If you
need to update the BIOS, do not shut down or reset the system while the
BIOS is updating. This is to avoid possible boot failure.
How to Recover the AMIBIOS Image (-the Main BIOS
Block)
An AMIBIOS fl ash chip consists of a boot sector block, and a main BIOS code block
(a main BIOS image). The boot sector block contains critical BIOS code, including
memory detection and recovery code to be used to fl ash a new BIOS image if the
original BIOS Image is corrupted. When the system is powered on, the boot sector
code executes fi rst. Once it is completed, the main BIOS code will continue with
system initialization and complete the bootup process.
Notes: BIOS Recovery described below is used when the main BIOS
block crashes. However, when the BIOS Boot sector crashes, you will need
to send the motherboard back to Supermicro for RMA repairs.
4.7.1 Boot Sector Recovery from a USB Device
This feature allows the user to recover a BIOS image using a USB device without
additional utilities needed. A user can download the BIOS image into a USB fl ash
device, and name the fi le "SUPER.ROM" for the recovery process to load the fi le.
A USB fl ash device such as a USB Flash Drive, a USB CDROM or a USB CDRW
device can be used for this purpose,
Insert the USB device that contains the new BIOS image (the ROM fi les) 1.
saved in a root directory into your USB drive.
While turning the power on, press and hold <Ctrl> and <Home> at the same 2.
time until the USB Access LED Indicator comes on. This might take a few
seconds.
Once the USB drive LED is on, release the <Ctrl> and <Home> keys. 3.
AMIBIOS will issue beep codes to indicate that the BIOS ROM fi le is being
updated.
When BIOS fl ashing is completed, the computer will reboot. Do not interrupt 4.
the fl ashing process until it is completed.
4-27
Page 88
X8DTG-QFUser’s Manual
4.7.2 Boot Sector Recovery from an IDE CD-ROM
This process is almost identical to the process of Boot Sector Recovery from a USB
device, except that the BIOS image fi le is loaded from a CD-ROM. Use a CD-R or
CD-RW drive to burn a CD with the BIOS image fi le in it, and name the fi le "SUPER.
ROM" for the recovery process to load the fi le.
4.7.3 Boot Sector Recovery from a Serial Port ("Serial
Flash")
This process, also known as "Serial Flash," allows the user to use a serial port to
load a BIOS image for Boot Sector recovery . This feature is usually used for embedded systems that rely on a serial port for remote access and debugging.
Requirements
In order to use Serial Flash for Boot Sector Recovery, you will need to meet the
following requirements.
The "Target system," the system that needs BIOS updates, must have a serial
•
port and "Serial Flash" support embedded in the BIOS image fi le.
The "Host system" should also have a serial port and a terminal program that
•
supports XModem Transfer protocol (Hyper Terminal for the Windows operating
systems, and minicom for Linux/FreeSBD, etc.).
A Null_modem serial cable
•
How to use Serial Flash for Boot Sector Recovery
Connect a Null_modem serial cable between the target system and the host 1.
system that runs the terminal program.
Make sure that the new BIOS Image fi le is accessible for the host system.2.
Start the terminal program on the host system and create a new connection. 3.
Use the following communication parameters for the new connection.
4. Power on your system and click the <Connect> button in the Hyper Terminal.
The terminal screen will display the following messages.
Press <SpaceBar> to update BIOS.
Confirm update BIOS? (y/n) y
Begin remote BIOS flash? (y/n) y
Starting remote flash.
Upload new BIOS file using Xmodem protocol.
5. Following the instructions given on the screen to update the BIOS. These
instructions are also shown below.
a. At the prompt, press the <SpaceBar> to update the BIOS.
b. When asked to confi rm BIOS updating, press <y> to confi rm BIOS
updates.
c. Press <y> again to begin fl ashing BIOS remotely.
Note: Be sure to complete Steps a~c above quickly because
you have a second or less to do so.
6. Once you've completed the instructions given, a screen will display to indicate
that remote fl ashing is starting and the new BIOS fi le is being uploaded.
7. To use Hyper Terminal to transfer the XModem protocol by using the "Send
File" dialog under the "Transfer" menu, follow the instructions below to complete XModem transfers.
a. Select the "Transfer" menu and enter <Send>.
b. Specify the location of the ROM fi le and select the proper protocol (XMo-
dem).
c. Press <Send> to start ROM File extraction. (See the picture below.)
4-29
Page 90
X8DTG-QFUser’s Manual
d. Once the ROM fi le extraction is completed, the message: "New BIOS re-
ceived OK" will display.
8. Once remote BIOS fl ash is completed, the system will reboot.
Note: AMIBIOS Serial Flash will work with any terminal communications
program that supports VT-100 and XModem protocols, including protocols
designed for GNU/LINUX & BSD operating systems such as minicom. It
is recommended that the terminal program be confi gured to use the 'CR/
LF' style of line termination.
4-30
Page 91
Appendix A: BIOS POST Error Codes
Appendix A
BIOS Error Beep Codes
During the POST (Power-On Self-Test) routines, which are performed each time
the system is powered on, errors may occur.
Non-fatal errors are those which, in most cases, allow the system to continue the
boot-up process. The error messages normally appear on the screen.
Fatal errors will not allow the system to continue the boot-up procedure. If a
fatal error occurs, you should consult with your system manufacturer for possible
repairs.
A-1 BIOS Error Beep Codes
BIOS Error Beep Codes
Beep CodeError MessageDescription
1 beepRefreshCircuits have been reset.
(Ready to power up)
5 short beeps + 1 long
beep
1 long beep + 8 short
beeps
Continuous high (pitch)
+ low (pitch)
Memory errorNo memory detected in the
system
Display memory
read/write error or
no video
System OverheatSystem overheat
No video display, video
adapter missing or with faulty
memory
A-1
Page 92
X8DTG-QF User's Manual
Notes
A-2
Page 93
Appendix B: Installing the Windows OS
Appendix B
Installing the Windows OS
After all hardware components have been installed, you must fi rst confi gure Intel
South Bridge RAID Settings before you install the Windows OS and other software
drivers. T o confi gure RAID settings, please refer to RAID Confi guration User Guides
posted on our web site at http://www.supermicro.com/support/manuals.
Note: The following OS installation instructions are written for the Windows
XP/2003 OS only. If you have the Windows 2008 or Windows Vista OS,
please follow the instructions displayed on your screen to install the OS.
B-1 Installing the Windows OS to a RAID System
Insert Microsoft's Windows XP/Windows 2003 Setup CD in the CD Drive, and 1.
the system will start booting up from CD.
Press the <F6> key when the message, "Press F6 if you need to install a 2.
third-party SCSI or RAID driver" displays.
When the Windows XP/Windows 2003 Setup screen appears, press <S> to 3.
specify additional device(s).
Insert the driver diskette, "Intel AA RAID XP/2003 Driver for ICH10R" into 4.
Drive A:," and press <Enter>.
Choose the Intel(R) ICH10R 5. SATA RAID Controller from the list indicated in
the XP/2003 Setup Screen, and press <Enter>.
Press <Enter> to continue the installation process. (If you need to specify any 6.
additional devices to be installed, do so at this time.) Once all devices are
specifi ed, press <Enter> to continue with the installation.
From the Windows XP/Windows 2003 Setup screen, press <Enter>. The 7.
XP/2003 Setup will automatically load all device fi les and then continue with
the Windows XP/Windows 2003 installation.
After the Windows XP/Windows 2003 OS Installation is complete, the system 8.
will automatically reboot.
B-1
Page 94
X8DTG-QF User's Manual
B-2 Installing the Windows OS to a Non-RAID System
Insert Microsoft's Windows XP/Windows 2003/Windows 2008/Windows Vista 1.
Setup CD in the CD Drive, and the system will start booting up from CD.
Continue with the OS installation. The Windows OS Setup screen will display.2.
From the Windows OS Setup screen, press the <Enter> key. The Windows 3.
OS Setup will automatically load all device fi les and then continue with the
Windows OS installation.
After the Windows OS Installation is complete, the system will automatically 4.
reboot.
Insert the Supermicro Setup CD that came with your motherboard into the CD 5.
Drive during system boot, and the main screen will display.
B-2
Page 95
Appendix C: Software Installation Instructions
Appendix C
Software Installation Instructions
C-1 Installing Software Programs
After you have installed the Windows Operating System, a screen as shown below
will appear. You are ready to install software programs and drivers that have not
yet been installed. To install these software programs and drivers, click the icons
to the right of these items.
Notes:
1. Click the icons showing a hand writing on the paper to view the readme
fi les for each item. Click on a computer icon to the right of an item to
install an item (from top to the bottom) one at a time. After installing each
item, you must reboot the system before proceeding with the next item
on the list. The bottom icon with a CD on it allows you to view the entire
contents of the CD.
2. When making a storage driver diskette by booting into a Driver CD,
please set the SATA Confi guration to "Compatible Mode" and confi gure
SATA as IDE in the BIOS Setup. After making the driver diskette, be sure
to change the SATA settings back to your original settings.
Driver/Tool Installation Display Screen
C-1
Page 96
X8DTG-QF User's Manual
C-2 Confi guring Supero Doctor III
The Supero Doctor III program is a Web-based management tool that supports
remote management capability. It includes Remote and Local Management tools.
The local management is called the SD III Client. The Supero Doctor III program
included on the CDROM that came with your motherboard allows you to monitor
the environment and operations of your system. Supero Doctor III displays crucial
system information such as CPU temperature, system voltages and fan status. See
the Figure below for a display of the Supero Doctor III interface.
Note: 1 The default user name and password are ADMIN.
Note 2: In the Windows OS environment, the Supero Doctor III settings
take precedence over the BIOS settings. When fi rst installed, Supero Doc-
tor III adopts the temperature threshold settings previously set in BIOS. Any
subsequent changes to these thresholds must be made within Supero Doctor, since the SD III settings override the BIOS settings. For the Windows
OS to adopt the BIOS temperature threshold settings, please change the
SDIII settings to be the same as those set in BIOS.
Supero Doctor III Interface Display Screen-I (Health Information)
C-2
Page 97
Appendix C: Software Installation Instructions
Supero Doctor III Interface Display Screen-II (Remote Control)
Note: SD III Software Revision 1.0 can be downloaded from our Web
site at: ftp://ftp.supermicro.com/utility/Supero_Doctor_III/. You can also
download SDIII User's Guide at: http://www.supermicro.com/PRODUCT/
Manuals/SDIII/UserGuide.pdf. For Linux, we will still recommend that you
use Supero Doctor II.
C-3
Page 98
X8DTG-QF User's Manual
Notes
C-4
Page 99
The products sold by Supermicro are not intended for and will not be used in life support systems, medical equipment, nuclear facilities or systems, aircraft, aircraft devices,
aircraft/emergency communication devices or other critical systems whose failure to perform be reasonably expected to result in signifi cant injury or loss of life or catastrophic
property damage. Accordingly, Supermicro disclaims any and all liability, and should buyer use or sell such products for use in such ultra-hazardous applications, it does so
entirely at its own risk. Furthermore, buyer agrees to fully indemnify, defend and hold Supermicro harmless for and against any and all claims, demands, actions, litigation, and
proceedings of any kind arising out of or related to such ultra-hazardous use or sale.
(Disclaimer Continued)
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.