Supero SuperServer 7047R-TRF User Manual

®
SUPER
USER'S MANUAL
Revision 1.0b
SUPERSERVER
7047R-TRF
manual, please see our web site at
www.supermicro.com.
Super Micro Computer, Inc. ("Supermicro") reserves the right to make changes to the product described in this manual at any time and without notice. This product, including software and documentation, is the property of Supermicro and/or its licensors, and is supplied only under a license. Any use or reproduction of this product is not allowed, except as expressly permitted by the terms of said license.
IN NO EVENT WILL SUPERMICRO BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL, SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO USE THIS PRODUCT OR DOCUMENTATION, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. IN PARTICULAR, SUPERMICRO SHALL NOT HAVE LIABILITY FOR ANY HARDWARE, SOFTWARE, OR DATA STORED OR USED WITH THE PRODUCT, INCLUDING THE COSTS OF REPAIRING, REPLACING, INTEGRATING, INSTALLING OR RECOVERING SUCH HARDWARE, SOFTWARE, OR DATA.
Any disputes arising between manufacturer and customer shall be governed by the laws of Santa Clara County in the State of California, USA. The State of California, County of Santa Clara shall be the exclusive venue for the resolution of any such disputes. Super Micro's total liability for all claims will not exceed the price paid for the hardware product.
FCC Statement: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the manufacturer’s instruction manual, may cause harmful interference with radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case you will be required to correct the interference at your own expense.
California Best Management Practices Regulations for Perchlorate Materials: This Perchlorate warning applies only to products containing CR (Manganese Dioxide) Lithium coin cells. “Perchlorate Material-special handling may apply. See
www.dtsc.ca.gov/hazardouswaste/perchlorate
WARNING: Handling of lead solder materials used in this product may expose you to lead, a chemical known to the State of California to cause birth defects and other reproductive harm.
Manual Revision 1.0b Release Date: October 24, 2013
Unless you request and receive written permission from Super Micro Computer, Inc., you may not copy any part of this document.
Information in this document is subject to change without notice. Other products and companies referred to herein are trademarks or registered trademarks of their respective companies or mark holders.
Copyright © 2013 by Super Micro Computer, Inc. All rights reserved.
Printed in the United States of America
iii
Preface
Preface
About This Manual
This manual is written for professional system integrators and PC technicians. It provides information for the installation and use of the SuperServer 7047R-TRF. Installation and maintainance should be performed by experienced technicians only.
The SuperServer 7047R-TRF is a high-end server based on the SC745TQ-R920B 4U tower/rackmountable chassis and the X9DRi-F serverboard.
Manual Organization
Chapter 1: Introduction
The fi rst chapter provides a checklist of the main components included with the server system and describes the main features of the X9DRi-F serverboard and the SC745TQ-R920B chassis.
Chapter 2: Server Installation
This chapter describes the steps necessary to install the SuperServer 7047R-TRF into a rack and check out the server confi guration prior to powering up the system. If your server was ordered without processor and memory components, this chapter will refer you to the appropriate sections of the manual for their installation.
Chapter 3: System Interface
Refer here for details on the system interface, which includes the functions and information provided by the control panel on the chassis as well as other LEDs located throughout the system.
Chapter 4: System Safety
You should thoroughly familiarize yourself with this chapter for a general overview of safety precautions that should be followed when installing and servicing the SuperServer 7047R-TRF.
Chapter 5: Advanced Serverboard Setup
Chapter 5 provides detailed information on the X9DRi-F serverboard, including the locations and functions of connections, headers and jumpers. Refer to this chapter when adding or removing processors or main memory and when reconfi guring the serverboard.
SUPERSERVER 7047R-TRF USER'S MANUAL
iv
Chapter 6: Advanced Chassis Setup
Refer to Chapter 6 for detailed information on the SC745TQ-R920B server chassis. You should follow the procedures given in this chapter when installing, removing or reconfi guring SAS/SATA or peripheral drives and when replacing system power supply units and cooling fans.
Chapter 7: BIOS
The BIOS chapter includes an introduction to BIOS and provides detailed information on running the CMOS Setup Utility.
Appendix A: BIOS POST Error Codes Appendix B: Installing Windows Appendix C: System Specifi cations
Notes
Preface
v
vi
Table of Contents
Chapter 1 Introduction
1-1 Overview ......................................................................................................... 1-1
1-2 Serverboard Features ..................................................................................... 1-2
Processors ...................................................................................................... 1-2
Memory ........................................................................................................... 1-2
Serial ATA ....................................................................................................... 1-2
Onboard Controllers/Ports .............................................................................. 1-2
Graphics Controller ......................................................................................... 1-2
Other Features ................................................................................................ 1-3
1-3 Server Chassis Features ................................................................................ 1-3
System Power ................................................................................................. 1-3
Front Control Panel ......................................................................................... 1-3
I/O Backplane .................................................................................................. 1-3
Cooling System ............................................................................................... 1-3
1-4 Advanced Power Management (for -F Models Only) ..................................... 1-4
Intel® Intelligent Power Node Manager (NM) ................................................. 1-4
Manageability Engine (ME) ............................................................................. 1-4
1-4 Contacting Supermicro .................................................................................... 1-6
Chapter 2 Server Installation
2-1 Overview ......................................................................................................... 2-1
2-2 Unpacking the System .................................................................................... 2-1
2-3 Preparing for Setup ......................................................................................... 2-1
Choosing a Setup Location ............................................................................. 2-2
2-4 Warnings and Cautions ................................................................................... 2-2
Rack Precautions ............................................................................................ 2-2
Server Precautions .......................................................................................... 2-2
Rack Mounting Considerations ....................................................................... 2-3
Ambient Operating Temperature ................................................................ 2-3
Reduced Airfl ow ......................................................................................... 2-3
Mechanical Loading ................................................................................... 2-3
Circuit Overloading ..................................................................................... 2-3
Reliable Ground ......................................................................................... 2-4
2-5 Installing the System into a Rack ................................................................... 2-4
Identifying the Sections of the Rack Rails ...................................................... 2-4
Installing the Chassis Rails ............................................................................. 2-6
Installing the Rack Rails ................................................................................. 2-7
SUPERSERVER 7047R-TRF USER'S MANUAL
vii
Installing the Server into the Rack .................................................................. 2-8
2-6 Checking the Serverboard Setup .................................................................... 2-9
2-7 Checking the Drive Bay Setup ...................................................................... 2-10
Chapter 3 System Interface
3-1 Overview ......................................................................................................... 3-1
3-2 Control Panel Buttons ..................................................................................... 3-1
Power .............................................................................................................. 3-1
Reset ............................................................................................................... 3-1
3-3 Control Panel LEDs ........................................................................................ 3-2
Power .............................................................................................................. 3-2
HDD ................................................................................................................. 3-2
NIC1 ................................................................................................................ 3-2
NIC2 ................................................................................................................ 3-2
Information LED .............................................................................................. 3-3
3-4 Drive Carrier LEDs .......................................................................................... 3-3
Chapter 4 Standardized Warning Statements for AC Systems
4-1 About Standardized Warning Statements ....................................................... 4-1
Warning Defi nition ........................................................................................... 4-1
Installation Instructions .................................................................................... 4-4
Circuit Breaker ................................................................................................ 4-5
Power Disconnection Warning ........................................................................ 4-6
Equipment Installation ..................................................................................... 4-8
Restricted Area ................................................................................................ 4-9
Battery Handling ............................................................................................ 4-10
Redundant Power Supplies .......................................................................... 4-12
Backplane Voltage ........................................................................................ 4-13
Comply with Local and National Electrical Codes ........................................ 4-14
Product Disposal ........................................................................................... 4-15
Hot Swap Fan Warning ................................................................................. 4-16
Power Cable and AC Adapter ...................................................................... 4-18
Chapter 5 Advanced Serverboard Setup
5-1 Handling the Serverboard ............................................................................... 5-1
Precautions ..................................................................................................... 5-1
Unpacking ....................................................................................................... 5-1
5-2 Processor and Heatsink Installation................................................................ 5-2
Installing a Passive CPU Heatsink ................................................................. 5-6
Removing the Heatsink ................................................................................... 5-7
Table of Contents
viii
5-3 Connecting Cables .......................................................................................... 5-8
Connecting Data Cables ................................................................................. 5-8
Connecting Power Cables .............................................................................. 5-8
Connecting the Control Panel ......................................................................... 5-8
5-4 I/O Ports .......................................................................................................... 5-9
5-5 Installing Memory .......................................................................................... 5-10
Memory Support ............................................................................................ 5-10
DIMM Module Population Confi guration ...................................................5-11
5-6 Adding PCI Expansion Cards ....................................................................... 5-12
5-7 Serverboard Details ...................................................................................... 5-13
5-8 Connector Defi nitions ................................................................................... 5-16
5-9 Jumper Settings ............................................................................................ 5-23
Explanation of Jumpers ................................................................................ 5-23
5-10 Onboard Indicators ........................................................................................ 5-25
5-11 SATA Drive Connections ............................................................................... 5-26
5-12 Installing Software ......................................................................................... 5-27
SuperDoctor III .............................................................................................. 5-28
5-14 Serverboard Battery ...................................................................................... 5-30
Chapter 6 Advanced Chassis Setup
6-1 Static-Sensitive Devices .................................................................................. 6-1
Precautions ..................................................................................................... 6-1
6-2 Front Control Panel ......................................................................................... 6-2
6-3 System Fans ................................................................................................... 6-4
Fan Failure ...................................................................................................... 6-4
6-4 Drive Bay Installation ...................................................................................... 6-6
SATA Drives .................................................................................................... 6-6
SATA Backplane .............................................................................................. 6-7
Storage Module ............................................................................................... 6-8
6-5 Power Supply .................................................................................................. 6-9
Power Supply Failure ...................................................................................... 6-9
Chapter 7 BIOS
7-1 Introduction ...................................................................................................... 7-1
Starting the Setup Utility ................................................................................. 7-1
7-2 Main Menu ...................................................................................................... 7-2
System Time/System Date ............................................................................. 7-2
7-3 Advanced Settings Menu ................................................................................ 7-2
7-4 Event Logs .................................................................................................... 7-22
7-5 IPMI ............................................................................................................... 7-23
SUPERSERVER 7047R-TRF USER'S MANUAL
7-6 Boot ............................................................................................................... 7-25
7-7 Security ......................................................................................................... 7-25
7-8 Save & Exit ................................................................................................... 7-26
Appendix A BIOS POST Error Codes Appendix B System Specifi cations
Drive Bays .......................................................................................................B-1
Peripheral Drive Bays .....................................................................................B-1
Expansion Slots ..............................................................................................B-1
Serverboard .....................................................................................................B-2
ix
Table of Contents
Notes
x
SUPERSERVER 7047R-TRF USER'S MANUAL
Chapter 1
Introduction
1-1 Overview
The SUPERSERVER 7047R-TRF is a high-end server comprised of two main subsystems: the SC745TQ-R920B 4U/tower chassis and the X9DRi-F serverboard. Please refer to our web site for information on operating systems that have been certifi ed for use with the system (www.supermicro.com).
In addition to the serverboard and chassis, various hardware components have been included with the 7047R-TRF, as listed below:
Two (2) passive CPU heatsinks (SNK-P0048PS)
Three (3) 8-cm system fans (FAN-0074L4)
Two (2) 8-cm rear exhaust fans (FAN-0082L4)
One (1) air shroud (MCP-310-49001-0N)
One (1) 20" front control 16-to-16 pin ribbon cable (CBL-0087)
Four (4) 200 mm 4-to-4 Pin Middle Fan Power Extension cables (CBL-0216L)
SAS Accessories
One (1) SAS backplane (BPN-SAS-743TQ) Two (2) 40-cm 8-to-8-pin ribbon cable w/tube for SGPIO (CBL-157L) Six (6) 35-cm SATA cables (CBL-0061L) Eight (8) 3.5" drive trays (MCP-220-00092-0B)
One rackmount kit (Optional: CSE-PT26)
Note: For your system to work properly, please follow the links below to download all necessary drivers/utilities and the user’s manual for your server.
Supermicro product manuals: http://www.supermicro.com/support/manuals/
Product drivers and utilities: ftp://ftp.supermicro.com
Product safety information:
http://super-dev/about/policies/safety_information.cfm
If you have any questions, please contact our support team at:
support@supermicor.com
Chapter 1: Introduction
1-1
1-2
SUPERSERVER 7047R-TRF USER'S MANUAL
1-2 Serverboard Features
At the heart of the SuperServer 7047R-TRF lies the X9DRi-F, a dual processor serverboard based on the Intel PCH C602/C606 chipset. Below are the main features of the X9DRi-F. (See Figure 1-1 for a block diagram of the chipset).
Processors
The X9DRi-F supports single or dual E5-2600 V2 series processors in Socket R LGA2011 type sockets. Please refer to our web site for a complete listing of supported processors (www.supermicro.com).
Note: If only one CPU is installed, then only half the PCI-E slots (PCI-E 1~3) will function in the server. The system needs both CPUs installed for all PCI-E slots to funtion.
Memory
The X9DRi-F has 16 single/dual/tri/quad channel 240-pin DIMM sockets that can support up to 512 GB of DDR3 1866/1600/1333/1066/800 MHz registered ECC SDRAM in two-channel memory bus. Memory sizes of 1GB, 2GB, 4GB, 8GB, 16GB and 32GB @ 1.35V/1.5V voltages are supported. Please refer to Chapter 5 for installing memory.
Serial ATA
An on-chip (PCH C606) SATA controller is integrated into theX9DRi-F to provide a six-port, 3 Gb/sec SATA subsystem, which is RAID 0, 1, 5 and 10 supported. The SATA drives are hot-swappable units.
Note: You must have RAID set up to enable the hot-swap capability of the SATA drives. Documentation on RAID setup guidelines can be found on our web site.
Onboard Controllers/Ports
The color-coded I/O ports on the X9DRi-F include two COM ports (one header and one port), a VGA (monitor) port, eleven USB 2.0 ports (4x rear, 6x header, 1x Type A), two gigabit Ethernet ports and one dedicated IPMI LAN port.
Note 1: For more information on IPMI confi guration, please refer to the IPMI User's Guide posted on our website at http://www.supermicro.com/support/manuals/
Graphics Controller
The X9DRi-F features an integrated Nuvoton WP450R BMC Base-board Controller (BMC) chip, which also acts as a video controller..
1-3
Chapter 1: Introduction
Other Features
Other onboard features that promote system health include onboard voltage monitors, auto-switching voltage regulators, chassis and CPU overheat sensors, power management, AC power loss recovery, virus protection and BIOS rescue.
1-3 Server Chassis Features
The following is a general outline of the main features of the SC745TQ-R920B server chassis.
System Power
The SC745TQ-R920B features dual redundant 920 Watt power supply. Power must be removed from the server before replacing a failed power supply unless a second (optional) 920 Watt power module is installed to provide the system with redundant power.
Front Control Panel
The control panel on the SuperServer 7047R-TRF provides you with system monitoring and control. LEDs indicate system power, HDD activity, network activity, system overheat and power supply failure. A main power button and a system reset button are also included. In addition, two USB ports have been incorporated into the control panel to provide front side USB access.
I/O Backplane
The SC745TQ-R920B is an extended ATX form factor chassis that may be used in either a tower or a 4U rackmount confi guration. The I/O backplane provides seven tool-less motherboard expansion slots, one COM port, one parallel port, one VGA port, two USB 2.0 ports, PS/2 mouse and keyboard ports, two gigabit Ethernet ports and a dedicated IPMI LAN port.
Cooling System
The chassis has an innovative cooling design that includes three 8-cm hot-plug system cooling fans located in the middle section of the chassis as well as two 8-cm hot-plug exhaust fans located at the rear of the chassis. An air shroud channels the airfl ow from the system fans to effi ciently cool the processor area of the system. The power supply module also includes a cooling fan.
1-4
SUPERSERVER 7047R-TRF USER'S MANUAL
1-4 Advanced Power Management (for -F Models Only)
Intel® Intelligent Power Node Manager (NM)
The Intel® Intelligent Power Node Manager (IPNM) provides your system with real-time thermal control and power management for maximum energy effi ciency. Although IPNM Specifi cation Version 1.5 is supported by the BMC (Baseboard Management Controller), your system must also have IPNM-compatible Manageability Engine (ME) fi rmware installed to use this feature.
Manageability Engine (ME)
The Manageability Engine, which is an ARC controller embedded in the IOH (I/O Hub), provides Server Platform Services (SPS) to your system. The services provided by SPS are different from those proveded by the ME on client platforms.
1-5
Chapter 1: Introduction
Figure 1-1. Intel PCH C602/C606 Chipset:
System Block Diagram
Note: This is a general block diagram. Please see Chapter 5 for details.
SLOT 2
KB
MS
COM1 External
#0-5
#0-6
Ports 4~7
Ports 0~3
#0-4
#0-3
#0-2
#0-1
#1-4
#1-3
#1-2
#1-1
DDR3
800/1066/1333
1600/1866
QPI
QPI
8G
LANE6
SLOT 1
COM2 Header
SLOT 3
PCI-E X8
USB 2.0
3.0 Gb/S
PCH C602/C606
PCI-E X16 G3
DMI2
LANE5
LANE1/2/3/4
SPI
P0
SIO
W83527
USB
SATA
2 Rear 4 Front
1 Type-A
BMC
PCI-E X8 G3
PCI-32
#1-5
#1-6
PCI-E X8 G3
SAS
8 SNB CORE DDR3
QPI 8G
SAS SAS
P1
P1
P0
PCI-E X4 G3
8 SNB CORE
DDR3
E5-2600 Series
Processor
E5-2600 Series
Processor
SLOT 4
SLOT 5
PCI-E X16
PCI-E X16
PCI-E X16
SLOT 6
PCI-E X8
PCI-E X8 G3
PCI-E X16 G3
PCI-E X16 G3
6.0 Gb/S
FOR PORT 0/1
PCI-E X8
82580
LAN
VGA
PCI-E X4
#2
#3A
#3B
#1B
#1A
DMI2
DMI2
#2
#1
#3
DMI2 4GB/s
8GB/s
#0~#6
#0~#8
DDR3
800/1066/1333
1600/1866
1-6
SUPERSERVER 7047R-TRF USER'S MANUAL
1-4 Contacting Supermicro
Headquarters
Address: Super Micro Computer, Inc.
980 Rock Ave.
San Jose, CA 95131 U.S.A. Tel: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: marketing@supermicro.com (General Information)
support@supermicro.com (Technical Support) Web Site:
www.supermicro.com
Europe
Address: Super Micro Computer B.V.
Het Sterrenbeeld 28, 5215 ML
's-Hertogenbosch, The Netherlands Tel: +31 (0) 73-6400390 Fax: +31 (0) 73-6416525 Email: sales@supermicro.nl (General Information)
support@supermicro.nl (Technical Support)
rma@supermicro.nl (Customer Support)
Asia-Pacifi c
Address: Super Micro Computer, Inc.
3F, No. 150, Jian 1st Rd.
Zhonghe Dist., New Taipei City 23511
Taiwan (R.O.C)
Tel: +886-(2) 8226-3990 Fax: +886-(2) 8226-3992 Web Site:
www.supermicro.com.tw
Technical Support: Email: support@supermicro.com.tw Tel: +886-(2)-8226-3990
Chapter 2: Server Installation
2-1
Chapter 2
Server Installation
2-1 Overview
This chapter provides a quick setup checklist to get your SuperServer 7047R-TRF up and running. Following these steps in the order given should enable you to have the system operational within a minimum amount of time. This quick setup assumes that your system has come to you with the processors and memory preinstalled. If your system is not already fully integrated with a serverboard, processors, system memory etc., please turn to the chapter or section noted in each step for details on installing specifi c components.
The SuperServer 7047R-TRF may be employed either as a tower or mounted in a rack as a 4U rackmount chassis. If using it as a tower unit, please read the Server Precautions in the next section and then skip ahead to Section 2-5.
2-2 Unpacking the System
You should inspect the box the system was shipped in and note if it was damaged in any way. If the server itself shows damage you should fi le a damage claim with the carrier who delivered it.
Decide on a suitable location for the SuperServer 7047R-TRF. It should be situated in a clean, dust-free area that is well ventilated. Avoid areas where heat, electrical noise and electromagnetic fi elds are generated. You will also need it placed near a grounded power outlet. Be sure to read the Rack and Server Precautions in the next section.
2-3 Preparing for Setup
The box the system was shipped in may include two sets of rail assemblies, two rail mounting brackets and mounting screws needed for installing the system into a rack (optional kit). Follow the steps in the order given to complete the installation process in a minimum amount of time. Please read this section in its entirety before you begin the installation procedure outlined in the sections that follow.
2-2
SUPERSERVER 7047R-TRF USER'S MANUAL
Choosing a Setup Location
Leave enough clearance in front of the rack to enable you to open the front door
completely (~25 inches) and approximately 30 inches of clearance in the back of the rack to allow for suffi cient airfl ow and ease in servicing.
This product is not suitable for use with visual display work place devices
acccording to §2 of the the German Ordinance for Work with Visual Display Units.
2-4 Warnings and Cautions
Rack Precautions
Ensure that the leveling jacks on the bottom of the rack are fully extended to
the fl oor with the full weight of the rack resting on them.
In single rack installation, stabilizers should be attached to the rack. In multiple
rack installations, the racks should be coupled together.
Always make sure the rack is stable before extending a component from the
rack.
You should extend only one component at a time - extending two or more
simultaneously may cause the rack to become unstable.
Slide/rail-mounted equipment is not to be used as a shelf or workspace.
Server Precautions
Review the electrical and general safety precautions in Chapter 4.
Determine the placement of each component in the rack before you install the
rails.
Install the heaviest server components on the bottom of the rack fi rst, and then
work up.
Use a regulating uninterruptible power supply (UPS) to protect the server from
power surges, voltage spikes and to keep your system operating in case of a power failure.
Allow the hot plug SATA drives and power supply modules to cool before
touching them.
Always keep the rack's front door and all panels and components on the servers
closed when not servicing to maintain proper cooling.
Chapter 2: Server Installation
2-3
Rack Mounting Considerations
Warning! To prevent bodily injury when mounting or servicing this unit in a
rack, you must take special precautions to ensure that the system remains stable. The following guidelines are provided to ensure your safety:
This unit should be mounted at the bottom of the rack if it is the only unit in
the rack.
When mounting this unit in a partially fi lled rack, load the rack from the bottom
to the top with the heaviest component at the bottom of the rack.
If the rack is provided with stabilizing devices, install the stabilizers before
mounting or servicing the unit in the rack.
Ambient Operating Temperature
If installed in a closed or multi-unit rack assembly, the ambient operating temperature of the rack environment may be greater than the ambient temperature of the room. Therefore, consideration should be given to installing the equipment in an environment compatible with the manufacturer’s maximum rated ambient temperature (Tmra).
Reduced Airfl ow
Equipment should be mounted into a rack so that the amount of airfl ow required for safe operation is not compromised.
Mechanical Loading
Equipment should be mounted into a rack so that a hazardous condition does not arise due to uneven mechanical loading.
Circuit Overloading
Consideration should be given to the connection of the equipment to the power supply circuitry and the effect that any possible overloading of circuits might have on overcurrent protection and power supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.
2-4
SUPERSERVER 7047R-TRF USER'S MANUAL
Reliable Ground
A reliable ground must be maintained at all times. To ensure this, the rack itself should be grounded. Particular attention should be given to power supply connections other than the direct connections to the branch circuit (i.e. the use of power strips, etc.).
2-5 Installing the System into a Rack
This section provides information on installing the system into a rack unit. Rack installation requires the use of the optional rackmount kit. If the system has already been mounted into a rack or if you are using it as a tower, you can skip ahead to Sections 2-5 and 2-6.
There are a variety of rack units on the market, which may mean the assembly procedure will differ slightly. The following is a guideline for installing the server into a rack with the rack rails provided in the rackmount kit. You should also refer to the installation instructions that came with the rack unit you are using.
Warning: Do not pick up the server with the front handles. They are
designed to pull the system from a rack only.
Stability Hazard: The rack stabilizing mechanism must be in place, or the
rack must be bolted to the fl oor before you slide the unit out for servicing. Failure to stabilize the rack can cause the rack to tip over.
Warning: When initially installing the server to a rack, test that the rail locking tabs engage to prevent the server from being overextended. Have a rack lift in place as a precaution in case the test fails.
Warning: In any instance of pulling the system from the rack, always use a rack lift and follow all associated safety precautions.
Identifying the Sections of the Rack Rails
The optional rackmount kit includes two rack rail assemblies. Each of these assemblies consist of three sections: an inner fi xed chassis rail that secures to the chassis, an outer rack rail that secures directly to the rack itself and two rail brackets, which also attack to the rack (see Figure 2-1.) The inner and outer rails must be detached from each other to install.
To remove the inner chassis rail, pull it out as far as possible - you should hear a "click" sound as a locking tab emerges from inside the rail assembly and locks the inner rail. Depress the locking tab to pull the inner rail completely out. Do this for both assemblies (one for each side).
Chapter 2: Server Installation
2-5
Figure 2-1. Identifying the Sections of the Rack Rails
Inner ail
ter ail
ail raets
2-6
SUPERSERVER 7047R-TRF USER'S MANUAL
Figure 2-2. Preparing to Install the Chassis Rails
Installing the Chassis Rails
You will need to remove the top cover and the feet to add rack rails to the chassis. First, remove the top and right covers (top and left covers when standing as a tower chassis) by fi rst removing the screws that secure them to the chassis. Depress the button on the top (side if tower) of the chassis to release the cover and then pull the cover off. Then unscrew the four feet and remove them from the chassis (see Figure 2-2).
You can now attach rack rails to the top and bottom (now the sides) of the chassis. First add the rack handles. Then position the inner chassis rail sections you just removed along the side of the chassis making sure the screw holes line up. Note that these two rails are left/right specifi c. Screw the rail securely to the side of the chassis (see Figure 2-3). Repeat this procedure for the other rail on the other side of the chassis. You will also need to attach the rail brackets when installing into a telco rack.
Locking Tabs: As mentioned, the chassis rails have a locking tab, which serves two functions. The fi rst is to lock the server into place when installed and pushed fully into the rack, which is its normal position. Secondly, these tabs also lock the server in place when fully extended from the rack. This prevents the server from coming completely out of the rack when you pull it out for servicing.
Chapter 2: Server Installation
2-7
Installing the Rack Rails
Determine where you want to place the SuperServer 7047R-TRF in the rack. (See Rack and Server Precautions in Section 2-3.) Position the fi xed rack rail/sliding rail guide assemblies at the desired location in the rack, keeping the sliding rail guide facing the inside of the rack. Screw the assembly securely to the rack using the brackets provided. Attach the other assembly to the other side of the rack, making sure both are at the exact same height and with the rail guides facing inward.
Figure 2-3. Installing the Rails to the Chassis
2-8
SUPERSERVER 7047R-TRF USER'S MANUAL
Figure 2-4. Installing the Server into a Rack
Installing the Server into the Rack
You should now have rails attached to both the chassis and the rack unit. The next step is to install the server into the rack. You should have two brackets in the rack mount kit. Install these fi rst keeping in mind that they are left/right specifi c (marked with "L" and "R"). Then, line up the rear of the chassis rails with the front of the rack rails. Slide the chassis rails into the rack rails, keeping the pressure even on both sides (you may have to depress the locking tabs when inserting).
When the server has been pushed completely into the rack, you should hear the locking tabs "click". Finish by inserting and tightening the thumbscrews that hold the front of the server to the rack (see Figure 2-4).
Note: The fi gure above is for illustrative purposes only. Always install servers to the bottom of the rack fi rst.
Chapter 2: Server Installation
2-9
2-6 Checking the Serverboard Setup
After setting up the the system, you will need to open the unit to make sure the serverboard is properly installed and all the connections have been made.
Accessing the Inside of the System
1. If rack mounted, fi rst release the screws that secure the unit to the rack.
2. Grasp the two handles on either side and pull the unit straight out until it locks (you will hear a "click").
3. There are two screws that secure the cover to the chassis - remove these rst.
4. Locate the latch on the top (side if tower) of the chassis - depress where it says "push" then lift the latch to release the cover.
5. Lift the cover from the chassis to gain full access to the inside of the server. See Figure 2-5.
Checking the Components and Setup
1. You may have one or two processors already installed into the serverboard. Each processor should have its own heatsink attached. See Chapter 5 for instructions on processor installation.
2. Your server may have come with system memory already installed. Make sure all DIMMs are fully seated in their slots. For details on adding system memory, refer to Chapter 5.
3. If desired, you can install add-on cards to the system. See Chapter 5 for details on installing PCI add-on cards.
4. Make sure all power and data cables are properly connected and not blocking the chassis airfl ow. See Chapter 5 for details on cable connections.
2-10
SUPERSERVER 7047R-TRF USER'S MANUAL
2-7 Checking the Drive Bay Setup
Next, you should check to make sure the peripheral drives and the hard drives and backplane have been properly installed and all connections have been made.
Checking the Drives
1. All drives can be accessed from the front of the server. For servicing the optional DVD-ROM and IDE hard drives, you will need to remove the top/left chassis cover. The hard drives can be installed and removed from the front of the chassis without removing any chassis covers.
2. To install components into the 5.25" drive bays, you must fi rst remove the top/ left chassis cover as described in the previous section. Refer to Chapter 6 for details.
3. Refer to Chapter 6 if you need to reinstall a optional DVD-ROM disk drive to the system.
4. Depending upon your system's confi guration, your system may have one or more drives already installed. If you need to install hard drives, please refer to Chapter 6.
Checking the Airfl ow
1. Airfl ow is provided by four hot-swap 8-cm chassis fans working in conjunction with an air shroud. Two 8-cm exhaust fans are also mounted at the rear of the chassis. The system component layout was carefully designed to promote suffi cient airfl ow through the chassis.
2. Note that all power and data cables have been routed in such a way that they do not block the airfl ow generated by the fans. Keep this in mind when you reroute them after working on the system.
Supplying Power to the System
The last thing you must do is to provide input power to the system.
1. Plug the power cords from the power supplies unit into a high-quality power strip that offers protection from electrical noise and power surges.
2. It is recommended that you use an uninterruptible power supply (UPS).
3. Depress the power on button on the front of the chassis.
Chapter 2: Server Installation
2-11
Figure 2-5. Accessing the Inside of the System
(Rack Confi guration shown)
2-12
SUPERSERVER 7047R-TRF USER'S MANUAL
Notes
Chapter 3: System Interface
3-1
Chapter 3
System Interface
3-1 Overview
The control panel on the SUPERSERVER 7047R-TRF has several LEDs and two buttons. There are also two LEDs on each SATA drive carrier. These LEDs keep you constantly informed of the overall status of the system and the activity and health of specifi c components.
3-2 Control Panel Buttons
There are two push-buttons located on the front of the chassis: a power on/off button and a reset button.
Power
This is the main power button, which is used to apply or turn off the main system power. Turning off system power with this button removes the main power but keeps standby power supplied to the system.
Reset
Use the reset button to reboot the system.
3-2
SUPERSERVER 7047R-TRF USER'S MANUAL
3-3 Control Panel LEDs
The control panel located on the front of the SC745 chassis has six LEDs that provide you with critical information related to different parts of the system. This section explains what each LED indicates when illuminated and any corrective action you may need to take.
2
1
Power
Indicates power is being supplied to the system's power supply. This LED should normally be on when the system is operating.
HDD
Indicates SATA drive activity when fl ashing.
NIC1
Indicates network activity on LAN1 when fl ashing.
NIC2
Indicates network activity on LAN2 when fl ashing.
Loading...