Supero SUPERSERVER 7045B-8R+, SUPERSERVER 7045B-TR+ User Manual

SUPER
SUPERSERVER 7045B-8R+
S
UPERSERVER 7045B-TR+
®
1.0a
The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccuracies that may be contained in this document, makes no commitment to update or to keep current the information in this manual, or to notify any person or organization of the updates. Please Note: For the most up-to-date version of this
manual, please see our web site at www.supermicro.com.
SUPER MICRO COMPUTER reserves the right to make changes to the product described in this manual at any time and without notice. This product, including software, if any, and documenta­tion may not, in whole or in part, be copied, photocopied, reproduced, translated or reduced to any medium or machine without prior written consent.
IN NO EVENT WILL SUPER MICRO COMPUTER BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL, SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO USE THIS PRODUCT OR DOCUMENTATION, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. IN PARTICULAR, SUPER MICRO SHALL NOT HAVE LIABILITY FOR ANY HARDWARE, SOFTWARE, OR DATA STORED OR USED WITH THE PRODUCT, INCLUDING THE COSTS OF REPAIRING, REPLACING, INTEGRATING, INSTALLING OR RECOVERING SUCH HARDWARE, SOFTWARE, OR DATA.
Any disputes arising between manufacturer and customer shall be governed by the laws of Santa Clara County in the State of California, USA. The State of California, County of Santa Clara shall be the exclusive venue for the resolution of any such disputes. Super Micro's total liability for all claims will not exceed the price paid for the hardware product.
FCC Statement: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the manufacturer’s instruction manual, may cause harmful interference with radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case you will be required to correct the interference at your own expense.
WARNING: Handling of lead solder materials used in this product may expose you to lead, a chemical known to the State of California to cause birth defects and other reproductive harm.
Manual Revision 1.0a
Release Date: July 10, 2007
Unless you request and receive written permission from SUPER MICRO COMPUTER, you may not copy any part of this document.
Information in this document is subject to change without notice. Other products and companies referred to herein are trademarks or registered trademarks of their respective companies or mark holders.
Copyright © 2007 by SUPER MICRO COMPUTER INC. All rights reserved.
Printed in the United States of America
Preface
About This Manual
This manual is written for professional system integrators and PC technicians. It
provides information for the installation and use of the SuperServer 7045B-8R+/
7045B-TR+. Installation and maintenance should be performed by experienced
technicians only.
The SuperServer 7045B-8R+/7045B-TR+ is a high-end server based on the
SC745S2-R800/SC745TQ-R800 tower/4U rackmount chassis and the X7DB8+/
X7DBE+, a dual processor serverboard that supports dual Intel
processors at a Front Side (System) Bus speed of 1066 MHz and up to 64 GB of
registered FBD ECC DDR2-667/533 SDRAM.
®
XeonTM LGA 771
Preface
Manual Organization
Chapter 1: Introduction
The fi rst chapter provides a checklist of the main components included with the
server system and describes the main features of the X7DB8+/X7DBE+ serverboard
and the SC745S2-R800/SC745TQ-R800 chassis, which comprise the SuperServer
7045B-8R+/7045B-TR+.
Chapter 2: Server Installation
This chapter describes the steps necessary to install the SuperServer 7045B-
8R+/7045B-TR+ into a rack and check out the server confi guration prior to pow-
ering up the system. If your server was ordered without processor and memory
components, this chapter will refer you to the appropriate sections of the manual
for their installation.
Chapter 3: System Interface
Refer here for details on the system interface, which includes the functions and
information provided by the control panel on the chassis as well as other LEDs
located throughout the system.
iii
SUPERSERVER 7045B-8R+/7045B-TR+ User's Manual
Chapter 4: System Safety
You should thoroughly familiarize yourself with this chapter for a general overview
of safety precautions that should be followed when installing and servicing the
SuperServer 7045B-8R+/7045B-TR+.
Chapter 5: Advanced Serverboard Setup
Chapter 5 provides detailed information on the X7DB8+/X7DBE+ serverboard,
including the locations and functions of connections, headers and jumpers. Refer
to this chapter when adding or removing processors or main memory and when
reconfi guring the serverboard.
Chapter 6: Advanced Chassis Setup
Refer to Chapter 6 for detailed information on the SC745S2-R800/SC745TQ-R800
server chassis. You should follow the procedures given in this chapter when install-
ing, removing or reconfi guring SCSI /SATA or peripheral drives and when replacing
system power supply units and cooling fans.
Chapter 7: BIOS
The BIOS chapter includes an introduction to BIOS and provides detailed informa-
tion on running the CMOS Setup Utility.
Appendix A: BIOS POST Codes
Appendix B: Software Installation
Appendix C: System Specifi cations
iv
Notes
Preface
v
SUPERSERVER 7045B-8R+/7045B-TR+ User's Manual
Table of Contents
Preface
About This Manual ...................................................................................................... iii
Manual Organization ................................................................................................... iii
Chapter 1: Introduction
1-1 Overview ......................................................................................................... 1-1
1-2 Serverboard Features ..................................................................................... 1-2
1-3 Server Chassis Features ................................................................................ 1-4
1-4 Contacting Super Micro .................................................................................. 1-6
Chapter 2: Server Installation
2-1 Overview ......................................................................................................... 2-1
2-2 Unpacking the System ................................................................................... 2-1
2-3 Preparing for Setup ........................................................................................ 2-1
2-4 Installing the System into a Rack ................................................................... 2-4
2-5 Checking the Serverboard Setup ................................................................... 2-8
2-6 Checking the Drive Bay Setup ....................................................................... 2-9
Chapter 3: System Interface
3-1 Overview ......................................................................................................... 3-1
3-2 Control Panel Buttons .................................................................................... 3-1
Power ....................................................................................................... 3-1
Reset ........................................................................................................ 3-1
3-3 Control Panel LEDs ........................................................................................ 3-2
Power ....................................................................................................... 3-2
HDD .......................................................................................................... 3-2
NIC1 ......................................................................................................... 3-2
NIC2 ......................................................................................................... 3-2
Overheat/Fan Fail .................................................................................... 3-2
Power Fail ................................................................................................ 3-3
3-4 Drive Carrier LEDs ......................................................................................... 3-3
Chapter 4: System Safety
4-1 Electrical Safety Precautions .......................................................................... 4-1
4-2 General Safety Precautions ........................................................................... 4-2
4-3 ESD Precautions ............................................................................................ 4-3
4-4 Operating Precautions .................................................................................... 4-4
vi
Table of Contents
Chapter 5: Advanced Serverboard Setup
5-1 Handling the Serverboard .............................................................................. 5-1
5-2 Processor and Heatsink Installation ............................................................... 5-2
5-3 Connecting Cables ......................................................................................... 5-5
Connecting Data Cables .......................................................................... 5-5
Connecting Power Cables ....................................................................... 5-5
Connecting the Control Panel .................................................................. 5-6
5-4 I/O Ports ......................................................................................................... 5-7
5-5 Installing Memory ........................................................................................... 5-7
5-6 Adding PCI Cards ........................................................................................... 5-9
5-7 Serverboard Details ........................................................................................ 5-9
X7DB8+ Layout ...................................................................................... 5-10
X7DB8+ Quick Reference ...................................................................... 5-11
5-8 Connector Defi nitions ................................................................................... 5-12
ATX Power Connector ........................................................................... 5-12
Secondary Power Connector ................................................................. 5-12
Processor Power Connector .................................................................. 5-12
NMI Button ............................................................................................. 5-12
Power LED ............................................................................................. 5-12
HDD LED ............................................................................................... 5-13
NIC1 LED ............................................................................................... 5-13
NIC2 LED ............................................................................................... 5-13
Overheat/Fan Fail LED .......................................................................... 5-13
Power Fail LED ...................................................................................... 5-13
Reset Button .......................................................................................... 5-14
Power Button .......................................................................................... 5-14
Universal Serial Bus (USB0/1) ............................................................... 5-14
Chassis Intrusion .................................................................................... 5-14
Serial Ports ............................................................................................. 5-15
Power Fail Header ................................................................................. 5-15
Fan Headers .......................................................................................... 5-15
Extra Universal Serial Bus Headers ...................................................... 5-16
Power LED/Speaker ............................................................................... 5-16
ATX PS/2 Keyboard and Mouse Ports .................................................. 5-16
Overheat LED ........................................................................................ 5-16
Wake-On-LAN ........................................................................................ 5-17
Wake-On-Ring ........................................................................................ 5-17
SMB ........................................................................................................ 5-17
SMBUS_PS ............................................................................................ 5-17
vii
SUPERSERVER 7045B-8R+/7045B-TR+ User's Manual
Alarm Reset ........................................................................................... 5-18
SGPIO .................................................................................................... 5-18
5-9 Jumper Settings ............................................................................................ 5-18
Explanation of Jumpers ......................................................................... 5-18
CMOS Clear ........................................................................................... 5-19
JLAN Enable/Disable ............................................................................. 5-19
Watch Dog Enable/Disable .................................................................... 5-19
3rd Power Supply Fail Detect Enable/Disable ....................................... 5-20
VGA Enable/Disable ............................................................................... 5-20
SCSI Controller Enable/Disable ............................................................. 5-20
SCSI Termination Enable/Disable .......................................................... 5-21
Compact Flash Master/Slave Select ...................................................... 5-21
SMBUS to PCI Enable/Disable .............................................................. 5-21
5-10 Onboard Indicators ....................................................................................... 5-22
JLAN1/JLAN2 LEDs ............................................................................... 5-22
SCSI Activity LED Indicators .................................................................. 5-22
Onboard Power LED .............................................................................. 2-22
5-11 Parallel Port, Floppy and Hard Drive Connections ...................................... 5-23
Parallel Port Connector .......................................................................... 5-23
Floppy Connector ................................................................................... 5-24
SATA Ports ............................................................................................. 5-24
IDE Connectors ...................................................................................... 5-25
Ultra320 SCSI Connectors ..................................................................... 5-26
Chapter 6: Advanced Chassis Setup
6-1 Static-Sensitive Devices ................................................................................. 6-1
6-2 Front Control Panel ........................................................................................ 6-3
6-3 System Fans ................................................................................................... 6-4
Fan Failure ............................................................................................... 6-4
Replacing Chassis Cooling Fans ............................................................. 6-4
6-4 Drive Bay Installation ...................................................................................... 6-6
SAS/SATA Drives ..................................................................................... 6-6
Installing Components in the 5.25" Drive Bays ....................................... 6-8
6-5 Power Supply ................................................................................................. 6-9
Power Supply Failure ............................................................................... 6-9
Removing/Replacing the Power Supply ................................................... 6-9
viii
Table of Contents
Chapter 7: BIOS
7-1 Introduction ..................................................................................................... 7-1
7-2 Running Setup ................................................................................................ 7-2
7-3 Main BIOS Setup ............................................................................................ 7-2
7-4 Advanced Setup ............................................................................................. 7-7
7-5 Security ......................................................................................................... 7-19
7-6 Boot .............................................................................................................. 7-20
7-7 Exit ................................................................................................................ 7-21
Appendices:
Appendix A: BIOS POST Messages
Appendix B: BIOS POST Codes
Appendix C: Software Installation
Appendix D: System Specifi cations
ix
S
UPERSERVER 7045B-8R+/7045B-TR+ User's Manual
Notes
x
Chapter 1: Introduction
Chapter 1
Introduction
1-1 Overview
The SuperServer 7045B-8R+/7045B-TR+ is a high-end server that is comprised of
two main subsystems: the SC745S2-R800/SC745TQ-R800 tower/4U server chassis
and the X7DB8+/X7DBE+ dual Intel Xeon processor serverboard. Please refer to
our web site for information on operating systems that have been certifi ed for use
with the SuperServer 7045B-8R+/7045B-TR+ (www.supermicro.com).
In addition to the serverboard and chassis, various hardware components have been
included with the SuperServer 7045B-8R+/7045B-TR+, as listed below:
Three (3) 8-cm hot-swap chassis fans (FAN-0072)
Two (2) 8-cm hot-swap rear exhaust fans (FAN-0081)
One (1) air shroud (CSE-PT0110)
One (1) 3.5" fl oppy drive [FPD-PNSC-02(01)]
Two (2) 5.25" dummy drive trays
One (1) ATA66 cable for DVD drive (CBL-0139L)
One (1) fl oppy cable (CBL-040L)
One (1) front control panel cable (CBL-0087)
One (1) I/O shield (CSE-PT55)
SCSI Accessories (7045B-8R+ only)
One (1) dual-channel SCSI backplane (CSE-SCA-743S2)
One (1) Ultra320 SCSI ribbon cable (CBL-037L-U320)
One (1) Ultra320 SCSI round cable (CBL-0063L)
Eight (8) SCSI hot-swap drive carriers [CSE-PT17(B)]
List continued on next page.
1-1
S
UPERSERVER 7045B-8R+/7045B-TR+ User's Manual
 SATA Accessories (7045B-TR+ only)
One (1) SATA backplane (CSE-SAS-743TQ)
Six (6) SATA cables (CBL-0061L)
Two (2) SATA LED cables (CBL-0157L)
Six (6) SATA hot-swap drive carriers [CSE-PT17(B)]
 Optional:
Two (2) CPU passive heatsinks (SNK-P0018)
One (1) rackmount kit [CSE-PT026(B)]
1-2 Serverboard Features
At the heart of the SuperServer 7045B-8R+/7045B-TR+ lies the X7DB8+/X7DBE+, a
dual processor serverboard based on the Intel 5000P chipset and designed to pro-
vide maximum performance. Below are the main features of the X7DB8+/X7DBE+.
(See Figure 1-1 for a block diagram of the 5000P chipset).
Processors
The X7DB8+/X7DBE+ supports single or dual LGA 771 type Intel Xeon processors
at a FSB speed of 1066 MHz. Please refer to the serverboard description pages
on our web site for a complete listing of supported processors (www.supermicro.
com).
Memory
The X7DB8+/X7DBE+ has sixteen 240-pin DIMM slots that can support up to 64
GB of FBD (Fully Buffered DIMM) ECC DDR2-667/533 SDRAM. The memory
operates in a 4-way interleaved confi gurations and requires requires modules of
the same size and speed to be installed four at a time. See Chapter 5 Section 5
for details.
Onboard SCSI (7045B-8R+ only)
An onboard Adaptec AIC-7902 dual-channel SCSI controller in integrated into the
X7DB8+, which supports eight 80-pin SCA Ultra320 SCSI hard drives. The SCSI
drives are connected to an SCA backplane that provides power, bus termination
and confi guration settings. The SCSI drives are hot-swappable units.
Note: The operating system you use must have RAID support to enable the hot-
swap capability and RAID function of the SCSI drives.
1-2
Chapter 1: Introduction
Serial ATA
A SATA controller is integrated into the South Bridge of the 5000P chipset to
provide a six-port Serial ATA subsystem, which is RAID 0, 1, 10 and 5 supported.
The Serial ATA drives are hot-swappable units.
Note: The operating system you use must have RAID support to enable the hot-
swap capability and RAID function of the Serial ATA drives.
PCI Expansion Slots
The X7DB8+/X7DBE+ has six PCI expansion slots, which includes two x8 PCI-
Express slots, one x4 PCI-Express slot, two 64-bit 133 MHz PCI-X slots and one
64-bit 100 MHz PCI-X slot. (On the X7DB8+, one 100 MHz PCI slot supports Zero
Channel RAID.)
Onboard Controllers/Ports
One fl oppy drive controller and two onboard ATA/100 controllers are provided to
support up to four IDE hard drives or ATAPI devices. The color-coded I/O ports
include one COM port (an additional COM header is located on the serverboard), a
VGA (monitor) port, a parallel port, two USB 2.0 ports, PS/2 mouse and keyboard
ports and two gigabit Ethernet ports.
ATI Graphics Controller
The X7DB8+/X7DBE+ features an integrated ATI video controller based on the
ES1000 graphics chip. The ES1000 was designed specifi cally for servers, featuring
low power consumption, high reliability and superior longevity.
Other Features
Other onboard features that promote system health include onboard voltage moni-
tors, a chassis intrusion header, auto-switching voltage regulators, chassis and CPU
overheat sensors, virus protection and BIOS rescue.
1-3
S
UPERSERVER 7045B-8R+/7045B-TR+ User's Manual
1-3 Server Chassis Features
The following is a general outline of the main features of the SC745S2-R800/
SC745TQ-R800 server chassis.
System Power
The SC745S2-R800/SC745TQ-R800 features a redundant 800W power supply
composed of two separate power modules. This power redundancy feature allows
you to replace a failed power supply without shutting down the system.
SCSI Subsystem (7045B-8R+ only)
The SC745S2-R800 chassis was designed to support eight dual-channel SCSI
hard drives, which are hot-swappable units.
Note: The operating system you use must have RAID support to enable the hot-
swap capability of the SCSI drives.
Serial ATA Subsystem
The SC745TQ-R800 supports up to six 3 Gb/s Serial ATA drives. The Serial ATA
drives are hot-swappable units and are connected to a backplane that provides
power and control.
Note: The operating system you use must have RAID support to enable the hot-
swap capability of the Serial ATA drives.
Front Control Panel
The control panel on the SuperServer 7045B-8R+/7045B-TR+ provides you with
system monitoring and control. LEDs indicate system power, HDD activity, net-
work activity, system overheat and power supply failure. A main power button and
a system reset button are also included. In addition, two USB ports have been
incorporated into the control panel to provide front side USB access.
I/O Backplane
The SC745S2-R800/SC745TQ-R800 is an ATX form factor chassis that may be
used in either a tower or a 4U rackmount confi guration. The I/O backplane provides
six motherboard expansion slots, one COM port, a parallel port, a VGA port, two
USB 2.0 ports, PS/2 mouse and keyboard ports and two gigabit Ethernet ports.
1-4
Chapter 1: Introduction
Cooling System
The SC745S2-R800/SC745TQ-R800 chassis has an innovative cooling design that
includes three 8-cm hot-plug system cooling fans located in the middle section of
the chassis as well as two 8-cm hot-plug exhaust fans located at the rear of the
chassis. An air shroud channels the airfl ow from the system fans to effi ciently
cool the processor area of the system. The power supply module also includes
a cooling fan.
Figure 1-1. Intel 5000P Chipset:
System Block Diagram
Note: This is a general block diagram. Please see Chapter 5 for details.
Slot 6: PCI-Exp x8/SEPC
Slot 2: PCI-X
LAN Ports (2)
Slot 5: PCI-Express x8
Slot 4: PCI-Express x8
AIC
7902
PXH
Slot 1: PCI-X
Slot 3: PCI- X
82563
CPU1
PCI-Exp
x8
PCI-Exp
x8
PCI-Exp
x4
PCI-Exp
x8
PCI-X 133
Kumeran
1067/1333 MT/s
5000P
MCH
PCI -E x 8
ESB2
PCI 32
ATI
ES1000
CPU2
FBD CH0
FBD CH1
FBD CH2
FBD CH3
PCI -E x 4
3.0 Gb/s
ATA 100
USB 2.0
LPC
FB D DI MM Ban k1
DDR2
SATA Ports (6)
IDE Ports (2)
USB Ports (5)
S I/O BIOS
FB D DI MM Ban k2
FB D DI MM Ban k3
FB D DI MM Ban k4
Note: The AIC-7902 SCSI controller is only on the X7DB8+ serverboard.
Kybd/
Mouse
1-5
Floppy
COM
Ports (2)
Parallel
Port
S
UPERSERVER 7045B-8R+/7045B-TR+ User's Manual
1-4 Contacting Super Micro
Headquarters
Address: Super Micro Computer, Inc. 980 Rock Ave. San Jose, CA 95131 U.S.A. Tel: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: marketing@supermicro.com (General Information) support@supermicro.com (Technical Support) Web Site: www.supermicro.com
Europe
Address: Super Micro Computer B.V. Het Sterrenbeeld 28, 5215 ML 's-Hertogenbosch, The Netherlands Tel: +31 (0) 73-6400390 Fax: +31 (0) 73-6416525 Email: sales@supermicro.nl (General Information) support@supermicro.nl (Technical Support) rma@supermicro.nl (Customer Support)
Asia-Pacifi c
Address: Super Micro, Taiwan 4F, No. 232-1, Liancheng Rd. Chung-Ho 235, Taipei, Taiwan, R.O.C. Tel: +886-(2) 8226-3990 Fax: +886-(2) 8226-3991 Web Site: www.supermicro.com.tw Technical Support: Email: support@supermicro.com.tw Tel: 886-2-8228-1366, ext.132 or 139
1-6
Chapter 2: Server Installation
Chapter 2
Server Installation
2-1 Overview
This chapter provides a quick setup checklist to get your SuperServer 7045B-8R+/
7045B-TR+ up and running. Following these steps in the order given should enable
you to have the system operational within a minimum amount of time. This quick
setup assumes that your system has come to you with the processors and memory
preinstalled. If your system is not already fully integrated with a serverboard, pro-
cessors, system memory etc., please turn to the chapter or section noted in each
step for details on installing specifi c components.
The 7045B-8R+/7045B-TR+ may be employed either as a tower or mounted in a
rack as a 4U rackmount chassis. If using it as a tower unit, please read the Server
Precautions in the next section and then skip ahead to Section 2-5.
2-2 Unpacking the System
You should inspect the box the system was shipped in and note if it was damaged
in any way. If the server itself shows damage you should fi le a damage claim with
the carrier who delivered it.
Decide on a suitable location for the SuperServer 7045B-8R+/7045B-TR+. It should
be situated in a clean, dust-free area that is well ventilated. Avoid areas where
heat, electrical noise and electromagnetic fi elds are generated. You will also need
it placed near a grounded power outlet. Be sure to read the Rack and Server
Precautions in the next section.
2-3 Preparing for Setup
The box the system was shipped in may include two sets of rail assemblies, two
rail mounting brackets and mounting screws needed for installing the system into a
rack (optional kit). Follow the steps in the order given to complete the installation
process in a minimum amount of time. Please read this section in its entirety before
you begin the installation procedure outlined in the sections that follow.
2-1
S
UPERSERVER 7045B-8R+/7045B-TR+ User's Manual
Choosing a Setup Location
- Leave enough clearance in front of the system to enable you to open the front
door completely (~25 inches).
- Leave approximately 30 inches of clearance in the back of the system to allow for
suffi cient airfl ow and ease in servicing.
- This product is for installation only in a Restricted Access Location (dedicated
equipment rooms, service closets and the like).
- This product is not suitable for use with visual display work place devices according
to §2 of the the German Ordinance for Work with Visual Display Units.
! !
Rack Precautions
- Ensure that the leveling jacks on the bottom of the rack are fully extended to the
fl oor with the full weight of the rack resting on them.
- In single rack installation, stabilizers should be attached to the rack.
- In multiple rack installations, the racks should be coupled together.
- Always make sure the rack is stable before extending a component from the
rack.
- You should extend only one component at a time - extending two or more simul-
taneously may cause the rack to become unstable.
Warnings and Precautions!
Server Precautions
- Review the electrical and general safety precautions in Chapter 4.
- Determine the placement of each component in the rack before you install the
rails.
- Install the heaviest server components on the bottom of the rack fi rst, and then
work up.
- Use a regulating uninterruptible power supply (UPS) to protect the server from
power surges, voltage spikes and to keep your system operating in case of a power
failure.
- Allow the hot plug SCSI/SATA drives and power supply units to cool before touch-
ing them.
-
Always keep the rack's front door and all panels and components on the servers
closed when not servicing to maintain proper cooling.
2-2
Chapter 2: Server Installation
Rack Mounting Considerations
Ambient Operating Temperature
If installed in a closed or multi-unit rack assembly, the ambient operating tempera-
ture of the rack environment may be greater than the ambient temperature of the
room. Therefore, consideration should be given to installing the equipment in an
environment compatible with the manufacturer’s maximum rated ambient tempera-
ture (Tmra).
Reduced Airfl ow
Equipment should be mounted into a rack so that the amount of airfl ow required
for safe operation is not compromised.
Mechanical Loading
Equipment should be mounted into a rack so that a hazardous condition does not
arise due to uneven mechanical loading.
Circuit Overloading
Consideration should be given to the connection of the equipment to the power
supply circuitry and the effect that any possible overloading of circuits might have
on overcurrent protection and power supply wiring. Appropriate consideration of
equipment nameplate ratings should be used when addressing this concern.
Reliable Ground
A reliable ground must be maintained at all times. To ensure this, the rack itself
should be grounded. Particular attention should be given to power supply connec-
tions other than the direct connections to the branch circuit (i.e. the use of power
strips, etc.).
2-3
S
UPERSERVER 7045B-8R+/7045B-TR+ User's Manual
2-4 Installing the System into a Rack
This section provides information on installing the system into a rack unit. Rack
installation requires the use of the optional rackmount kit. If the system has already
been mounted into a rack or if you are using it as a tower, you can skip ahead to
Sections 2-5 and 2-6. There are a variety of rack units on the market, which may
mean the assembly procedure will differ slightly. The following is a guideline for
installing the server into a rack with the rack rails provided in the rackmount kit.
You should also refer to the installation instructions that came with the rack unit
you are using.
Identifying the Sections of the Rack Rails
The optional rackmount kit includes two rack rail assemblies. Each of these as-
semblies consist of three sections: an inner fi xed chassis rail that secures to the
chassis, an outer rack rail that secures directly to the rack itself and two rail brackets,
which also attack to the rack (see Figure 2-1.) The inner and outer rails must be
detached from each other to install.
To remove the inner chassis rail, pull it out as far as possible - you should hear a
"click" sound as a locking tab emerges from inside the rail assembly and locks the
inner rail. Depress the locking tab to pull the inner rail completely out. Do this for
both assemblies (one for each side).
Figure 2-1. Identifying the Sections of the Rack Rails
Outer rail
Inner rail
Rail brackets
2-4
Chapter 2: Server Installation
Installing the Chassis Rails
You will need to remove the top cover and the feet to add rack rails to the chassis.
First, remove the top and right covers (top and left covers when standing as a tower
chassis) by fi rst removing the screws that secure them to the chassis. Depress
the button on the top (side if tower) of the chassis to release the cover and then
pull the cover off. Then unscrew the four feet and remove them from the chassis
(see Figure 2-2).
You can now attach rack rails to the top and bottom (now the sides) of the chassis.
First add the rack handles. Then position the inner chassis rail sections you just
removed along the side of the chassis making sure the screw holes line up. Note
that these two rails are left/right specifi c. Screw the rail securely to the side of the
chassis (see Figure 2-3). Repeat this procedure for the other rail on the other side
of the chassis. You will also need to attach the rail brackets when installing into a
telco rack.
Locking Tabs: As mentioned, the chassis rails have a locking tab, which serves
two functions. The fi rst is to lock the server into place when installed and pushed
fully into the rack, which is its normal position. Secondly, these tabs also lock the
server in place when fully extended from the rack. This prevents the server from
coming completely out of the rack when you pull it out for servicing.
Figure 2-2. Preparing to Install the Chassis Rails
2-5
S
UPERSERVER 7045B-8R+/7045B-TR+ User's Manual
Figure 2-3. Installing the Rails to the Chassis
Installing the Rack Rails
Determine where you want to place the SuperServer 7045B-8R+/7045B-TR+ in
the rack. (See Rack and Server Precautions in Section 2-3.) Position the fi xed
rack rail/sliding rail guide assemblies at the desired location in the rack, keeping
the sliding rail guide facing the inside of the rack. Screw the assembly securely
to the rack using the brackets provided. Attach the other assembly to the other
side of the rack, making sure both are at the exact same height and with the rail
guides facing inward.
2-6
Chapter 2: Server Installation
Installing the Server into the Rack
You should now have rails attached to both the chassis and the rack unit. The next
step is to install the server into the rack. You should have two brackets in the rack
mount kit. Install these fi rst keeping in mind that they are left/right specifi c (marked
with "L" and "R"). Then, line up the rear of the chassis rails with the front of the
rack rails. Slide the chassis rails into the rack rails, keeping the pressure even on
both sides (you may have to depress the locking tabs when inserting).
When the server has been pushed completely into the rack, you should hear the
locking tabs "click". Finish by inserting and tightening the thumbscrews that hold
the front of the server to the rack (see Figure 2-4).
Figure 2-4. Installing the Server into a Rack
2-7
S
UPERSERVER 7045B-8R+/7045B-TR+ User's Manual
2-5 Checking the Serverboard Setup
After setting up the the system, you will need to open the unit to make sure the
serverboard is properly installed and all the connections have been made.
1. Accessing the inside of the system (see Figure 2-5)
[If rack mounted, fi rst release the retention screws that secure the unit to the
rack. Grasp the two handles on either side and pull the unit straight out until it
locks (you will hear a "click").] There are two screws that secure the cover to
the chassis - remove these fi rst. Locate the latch on the top (side if tower) of
the chassis - depress where it says "push" then lift the latch to release the cover.
You can then lift the cover from the chassis to gain full access to the inside of
the server.
2. Check the CPUs (processors)
You may have one or two processors already installed into the serverboard. Each
processor should have its own heatsink attached. See Chapter 5 for instructions
on processor installation.
3. CPU clock ratio setting
The CPU speed should be automatically detected. No jumper or BIOS settings
need to be made.
4. Check the system memory
Your server may have come with system memory already installed. Make sure
all DIMMs are fully seated in their slots. For details on adding system memory,
refer to Chapter 5.
5. Installing add-on cards
If desired, you can install add-on cards to the system. See Chapter 5 for details
on installing PCI add-on cards.
6. Check all cable connections and airfl ow
Make sure all power and data cables are properly connected and not blocking
the chassis airfl ow. See Chapter 5 for details on cable connections.
2-8
Chapter 2: Server Installation
Figure 2-5. Accessing the Inside of the System
(Rack Confi guration shown)
2-6 Checking the Drive Bay Setup
Next, you should check to make sure the peripheral drives and the SCSI/SATA
drives and backplane have been properly installed and all connections have been
made.
1. Accessing the drive bays
All drives can be accessed from the front of the server. For servicing the CD-
ROM, IDE hard drives and fl oppy drives, you will need to remove the top/left
chassis cover. The SCSI disk drives can be installed and removed from the front
of the chassis without removing any chassis covers.
2. Installing components into the 5.25" drive bays
To install components into the 5.25" drive bays, you must fi rst remove the top/
left chassis cover as described in the previous section. Refer to Chapter 6 for
details.
3. Installing CD-ROM and fl oppy disk drives
Refer to Chapter 6 if you need to reinstall a CD-ROM and/or fl oppy disk drive
to the system.
2-9
S
UPERSERVER 7045B-8R+/7045B-TR+ User's Manual
4. Check the SCSI/SATA disk drives
Depending upon your system's confi guration, your system may have one or
more drives already installed. If you need to install SCSI or SATA drives, please
refer to Chapter 6.
5. Check the airfl ow
Airfl ow is provided by four hot-swap 8-cm chassis fans working in conjunction
with an air shroud. Two 8-cm exhaust fans are also mounted at the rear of the
chassis. The system component layout was carefully designed to promote suf-
fi cient airfl ow through the chassis. Also note that all power and data cables have
been routed in such a way that they do not block the airfl ow generated by the
fans. Keep this in mind when you reroute them after working on the system.
6. Supplying power to the system
The last thing you must do is to provide input power to the system. Plug the
power cords from the power supplies unit into a high-quality power strip that of-
fers protection from electrical noise and power surges. It is recommended that
you use an uninterruptible power supply (UPS). Finally, depress the power on
button on the front of the chassis.
2-10
Chapter 3: System Interface
Chapter 3
System Interface
3-1 Overview
The control panel on the 7045B-8R+/7045B-TR+ has several LEDs and two buttons.
There are also two LEDs on each SCSI drive carrier (7045B-8R+) and SATA drive
carrier (7045B-TR+). These LEDs keep you constantly informed of the overall status
of the system and the activity and health of specifi c components.
3-2 Control Panel Buttons
There are two push-buttons located on the front of the chassis. These are (in order
from left to right) a power on/off button and a reset button.
POWER: This is the main power button, which is used to apply or turn off
the main system power. Turning off system power with this button removes the
main power but keeps standby power supplied to the system.
RESET:
Use the reset button to reboot the system.
3-1
S
UPERSERVER 7045B-8R+/7045B-TR+ User's Manual
3-3 Control Panel LEDs
The control panel located on the front of the SC745S2-R800/SC745TQ-R800 chas-
sis has six LEDs that provide you with critical information related to different parts
of the system. This section explains what each LED indicates when illuminated
and any corrective action you may need to take.
Power:
LED should normally be on when the system is operating.
HDD: Indicates IDE channel activity. On the 7045B-8R+/7045B-TR+, this
LED indicates SCSI/SATA drive activity when fl ashing.
NIC1:
Indicates power is being supplied to the system's power supply. This
1
Indicates network activity on JLAN1 when fl ashing.
2
NIC2: Indicates network activity on JLAN2 when fl ashing.
Overheat/Fan Fail: When this LED fl ashes, it indicates a fan failure. When
on continuously it indicates an overheat condition, which may be caused by cables
obstructing the airfl ow in the system or the ambient room temperature being too
warm. Check the routing of the cables and make sure all fans are present and
operating normally. You should also check to make sure that the chassis covers
are installed. Finally, verify that the heatsinks are installed properly (see Chapter
5). This LED will remain fl ashing or on as long as the indicated condition exists.
3-2
Chapter 3: System Interface
Power Fail: Indicates a power supply module has failed. This should be
accompanied by an audible alarm. A backup power supply module will take the
load and keep the system running but the failed module will need to be replaced.
Refer to Chapter 6 for details on replacing the power supply. This LED should be
off when the system is operating normally.
3-4 Drive Carrier LEDs
SCSI Drives (7045B-8R+)
Each SCSI drive carrier has two LEDs.
Green: When illuminated, the green LED on the front of the SCSI drive car-
rier indicates drive activity. A connection to the SCSI SCA backplane enables this
LED to blink on and off when that particular drive is being accessed.
Red: The SAF-TE compliant backplane activates the red LED to indicate a
drive failure. If one of the SCSI drives fail, you should be notifi ed by your system
management software. Please refer to Chapter 6 for instructions on replacing failed
SCSI drives.
SATA Drives (7045B-TR+)
Green: Each Serial ATA drive carrier has a green LED. When illuminated,
this green LED (on the front of the SATA drive carrier) indicates drive activity. A
connection to the SATA backplane enables this LED to blink on and off when that
particular drive is being accessed. Please refer to Chapter 6 for instructions on
replacing failed SATA drives.
Red: The red LED to indicate an SATA drive failure. If one of the SATA drives
fail, you should be notifi ed by your system management software. Please refer to
Chapter 6 for instructions on replacing failed SATA drives.
3-3
S
UPERSERVER 7045B-8R+/7045B-TR+ User's Manual
Notes
3-4
Loading...
+ 92 hidden pages