SUPER
SUPER SERVER
6027B-TLF
®
USER’S MANUAL
1.0
The information in this User’s Manual has been carefully reviewed and is believed to be accurate.
The vendor assumes no responsibility for any inaccuracies that may be contained in this document,
makes no commitment to update or to keep current the information in this manual, or to notify any
person or organization of the updates. Please Note: For the most up-to-date version of this
manual, please see our web site at www.supermicro.com.
Super Micro Computer, Inc. ("Supermicro") reserves the right to make changes to the product
described in this manual at any time and without notice. This product, including software and documentation, is the property of Supermicro and/or its licensors, and is supplied only under a license.
Any use or reproduction of this product is not allowed, except as expressly permitted by the terms
of said license.
IN NO EVENT WILL SUPERMICRO BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL,
SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO
USE THIS PRODUCT OR DOCUMENTATION, EVEN IF ADVISED OF THE POSSIBILITY OF
SUCH DAMAGES. IN PARTICULAR, SUPERMICRO SHALL NOT HAVE LIABILITY FOR ANY
HARDWARE, SOFTWARE, OR DATA STORED OR USED WITH THE PRODUCT, INCLUDING THE
COSTS OF REPAIRING, REPLACING, INTEGRATING, INSTALLING OR RECOVERING SUCH
HARDWARE, SOFTWARE, OR DATA.
Any disputes arising between manufacturer and customer shall be governed by the laws of Santa
Clara County in the State of California, USA. The State of California, County of Santa Clara shall
be the exclusive venue for the resolution of any such disputes. Super Micro's total liability for all
claims will not exceed the price paid for the hardware product.
FCC Statement: This equipment has been tested and found to comply with the limits for a Class A
digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the manufacturer’s instruction manual, may cause harmful interference
with radio communications. Operation of this equipment in a residential area is likely to cause harmful
interference, in which case you will be required to correct the interference at your own expense.
California Best Management Practices Regulations for Perchlorate Materials: This Perchlorate warning applies only to products containing CR (Manganese Dioxide) Lithium coin cells. “Perchlorate
Material-special handling may apply. See www.dtsc.ca.gov/hazardouswaste/perchlorate”
WARNING: Handling of lead solder materials used in this
product may expose you to lead, a chemical known to the
State of California to cause birth defects and other reproductive harm.
Manual Revision 1.0
Release Date: September 18, 2012
Unless you request and receive written permission from Super Micro Computer, Inc., you may not
copy any part of this document.
Information in this document is subject to change without notice. Other products and companies
referred to herein are trademarks or registered trademarks of their respective companies or mark
holders.
Copyright © 2012 by Super Micro Computer, Inc.
All rights reserved.
Printed in the United States of America
Preface
About This Manual
This manual is written for professional system integrators and PC technicians. It
provides information for the installation and use of the SuperServer 6027B-TLF.
Installation and maintenance should be performed by experienced technicians only.
The SuperServer 6027B-TLF is a high-end server based on the SC823T-653LPB
2U rackmount chassis and the Super X9DBL-iF processor serverboard.
Manual Organization
Chapter 1: Introduction
Preface
The fi rst chapter provides a checklist of the main components included with the
server system and describes the main features of the X9DBL-iF serverboard and
the SC823T-653LPB chassis.
Chapter 2: Server Installation
This chapter describes the steps necessary to install the SuperServer 6027B-TLF
into a rack and check out the server confi guration prior to powering up the system.
Chapter 3: System Interface
Refer here for details on the system interface, which includes the functions and
information provided by the control panel on the chassis as well as other LEDs
located throughout the system.
Chapter 4: System Safety
You should thoroughly familiarize yourself with this chapter for a general overview
of safety precautions that should be followed when installing and servicing the
SuperServer 6027B-TLF.
iii
SUPER SERVER 6027B-TLF User's Manual
Chapter 5: Advanced Serverboard Setup
Chapter 5 provides detailed information on the X9DBL-iF serverboard, including the
locations and functions of connections, headers and jumpers. Refer to this chapter
when adding or removing processors or main memory and when reconfi guring the
serverboard.
Chapter 6: Advanced Chassis Setup
Refer to Chapter 6 for detailed information on the SC823T-653LPB server chassis.
You should follow the procedures given in this chapter when installing, removing or
reconfi guring SATA or peripheral drives and when replacing system power supply
modules and cooling fans.
Chapter 7: BIOS
The BIOS chapter includes an introduction to BIOS and provides detailed informa-
tion on running the CMOS Setup Utility.
Appendix A: POST Error Beep Codes
Appendix B: System Specifi cations
iv
Notes
Preface
v
SUPER SERVER 6027B-TLF User's Manual
Table of Contents
Chapter 1 Introduction
1-1 Overview ......................................................................................................... 1-1
1-2 Serverboard Features ..................................................................................... 1-2
Processors ...................................................................................................... 1-2
Memory ........................................................................................................... 1-2
SATA ................................................................................................................ 1-2
PCI Expansion ............................................................................................... 1-2
I/O Ports .......................................................................................................... 1-2
1-3 Server Chassis Features ................................................................................ 1-3
System Power ................................................................................................. 1-3
Control Panel .................................................................................................. 1-3
Cooling System ............................................................................................... 1-3
1-4 Contacting Supermicro .................................................................................... 1-5
Chapter 2 Server Installation
2-1 Overview .............................................................................................................. 2-1
2-2 Unpacking the System .................................................................................... 2-1
2-3 Preparing for Setup ......................................................................................... 2-1
Choosing a Setup Location ............................................................................. 2-1
Rack Precautions ............................................................................................ 2-2
Server Precautions .......................................................................................... 2-2
Rack Mounting Considerations ....................................................................... 2-3
Ambient Operating Temperature ................................................................ 2-3
Reduced Airfl ow ......................................................................................... 2-3
Mechanical Loading ................................................................................... 2-3
Circuit Overloading ..................................................................................... 2-3
Reliable Ground ......................................................................................... 2-3
2-4 Installing the System into a Rack ................................................................... 2-4
Identifying the Sections of the Rack Rails ...................................................... 2-4
Installing the Chassis Rails ............................................................................. 2-5
Installing the Rack Rails ................................................................................. 2-5
Installing the Server into the Rack .................................................................. 2-6
Installing the Server into a Telco Rack ........................................................... 2-7
Chapter 3 System Interface
3-1 Overview ......................................................................................................... 3-1
3-2 Control Panel Buttons ..................................................................................... 3-1
vi
Table of Contents
Reset ............................................................................................................... 3-1
Power .............................................................................................................. 3-1
3-3 Control Panel LEDs ........................................................................................ 3-2
Power .............................................................................................................. 3-2
HDD ................................................................................................................. 3-2
NIC1 ................................................................................................................ 3-2
NIC2 ................................................................................................................ 3-2
Information LED .............................................................................................. 3-3
3-4 Drive Carrier LEDs .......................................................................................... 3-3
Chapter 4 System Safety
4-1 Electrical Safety Precautions .......................................................................... 4-1
4-2 General Safety Precautions ............................................................................ 4-2
4-3 ESD Precautions ............................................................................................. 4-3
4-4 Operating Precautions .................................................................................... 4-4
Chapter 5 Advanced Serverboard Setup
5-1 Handling the Serverboard ............................................................................... 5-1
Precautions ..................................................................................................... 5-1
Unpacking ....................................................................................................... 5-1
5-2 Processor and Heatsink Installation................................................................ 5-2
Installing an LGA 1356 Processor .................................................................. 5-2
Installing a CPU Heatsink ............................................................................... 5-4
5-3 Connecting Cables .......................................................................................... 5-5
Connecting Data Cables ................................................................................. 5-5
Connecting Power Cables .............................................................................. 5-5
Connecting the Control Panel ......................................................................... 5-5
5-4 I/O Ports .......................................................................................................... 5-6
5-5 Installing Memory ............................................................................................ 5-7
5-6 Adding PCI Cards ......................................................................................... 5-10
5-7 Serverboard Details .......................................................................................5-11
X9DBL-iF Quick Reference ............................................................................5-11
5-8 Connector Defi nitions ................................................................................... 5-13
5-9 Jumper Settings ............................................................................................ 5-20
5-10 Onboard Indicators ........................................................................................ 5-22
5-11 SATA Ports .................................................................................................... 5-23
5-12 Installing Drivers ............................................................................................ 5-24
SuperDoctor III .............................................................................................. 5-25
Chapter 6 Advanced Chassis Setup
6-1 Static-Sensitive Devices .................................................................................. 6-1
vii
SUPER SERVER 6027B-TLF User's Manual
Precautions ..................................................................................................... 6-1
6-2 Control Panel .................................................................................................. 6-3
6-3 System Fans ................................................................................................... 6-3
Replacing System Cooling Fans ..................................................................... 6-3
6-4 Drive Bay Installation/Removal ....................................................................... 6-4
Accessing the Drive Bays ............................................................................... 6-4
SATA Drive Installation .................................................................................... 6-5
Installing a Component in the 5.25" Drive Bay ............................................... 6-7
DVD-ROM Drive Installation ........................................................................... 6-8
Power Supply Failure ...................................................................................... 6-9
Chapter 7 BIOS
7-1 Introduction ...................................................................................................... 7-1
Starting BIOS Setup Utility .............................................................................. 7-1
How To Change the Confi guration Data ......................................................... 7-2
Starting the Setup Utility ................................................................................. 7-2
7-2 Main Setup ...................................................................................................... 7-2
7-3 Advanced Setup Confi gurations...................................................................... 7-4
7-4 Event Logs .................................................................................................... 7-26
7-5 IPMI ............................................................................................................... 7-28
7-6 Boot ............................................................................................................... 7-30
7-7 Security ......................................................................................................... 7-31
7-8 Save & Exit ................................................................................................... 7-32
Appendix A BIOS Error Beep Codes
Appendix B System Specifi cations
viii
Chapter 1: Introduction
Chapter 1
Introduction
1-1 Overview
The SuperServer 6027B-TLF is a high-end server comprised of two main subsys-
tems: the SC823T-653LPB 2U server chassis and the X9DBL-iF dual processor
serverboard. Please refer to our web site for information on operating systems that
have been certifi ed for use with the system (www.supermicro.com).
In addition to the serverboard and chassis, various hardware components have
been included with the 6027B-TLF, as listed below:
• Four 8-cm fans (FAN-0126L4)
• One passive and one active CPU heatsink (SNK-P0038P and SNK-P0048AP4)
• One air shroud (MCP-290-28002-0N)
• SATA Accessories
One SATA backplane (BPN-SAS-823T)
Six 3.5" hard drive carriers (MCP-220-00092-0B)
Six SATA cables (CBL-0206L)
• One CD containing drivers and utilities
• One rackmount kit (CSE-PT25)
• SuperServer 6027B-TLF User's Manual
Note: a complete list of safety warnings is provided on the Supermicro web site at
http://super-dev/about/policies/safety_information.cfm
1-1
SUPER SERVER 6027B-TLF User's Manual
1-2 Serverboard Features
At the heart of the SuperServer 6027B-TLF lies the X9DBL-iF, a dual processor
serverboard based on Intel's C602 chipset. Below are the main features of the
X9DBL-iF (see Figure 1-1 for a block diagram of the chipset).
Processors
The X9DBL-iF supports up to two Intel® Xeon® E5-2400 Series processors (up to
95W TDP) in LGA 1356 sockets. Please refer to the serverboard description pages
on our web site for a complete listing of supported processors.
Memory
The X9DBL-iF has six DIMM sockets that can support up to 192 GB of ECC DDR3-
1600/1333/1066/800 R/LRDIMMs (LRDIMM = Reduced Load DIMMs) or up to 48GB
of ECC UDIMMs. Please refer to Chapter 5 for installing memory.
SATA
An on-chip SATA controller is integrated into the X9DBL-iF to provide two 6 Gb/
sec SATA3 ports and four 3 Gb/sec SATA2 ports, which are RAID 0, 1, 5 and 10
supported. Four SCU-SATA 3 Gb/sec SATA2 ports are also included onboard.
PCI Expansion
The system can support three PCI-E 3.0 x8, one PCI-E 3.0 x16, one PCI-E 3.0 x4
(in a x8 slot) and one 32-bit PCI slot.
I/O Ports
The color-coded I/O ports include one COM port, a VGA (monitor) port, two USB 2.0
ports, PS/2 mouse and keyboard ports and two gigabit Ethernet ports. A dedicated
IPMI LAN port is also included.
1-2
Chapter 1: Introduction
1-3 Server Chassis Features
The SC823T-653LPB is a 2U chassis that features six 3.5" hot-swap hard drive
bays and a high-effi ciency power supply. The following is a general outline of the
main features of the SC823T-653LPB chassis.
System Power
When confi gured as the SuperServer 6027B-TLF, the SC823T-653LPB chassis
includes a single 650W high-effi ciency power supply.
Control Panel
The control panel on the SC823T-653LPB provides important system monitoring
and control information. LEDs indicate power on, network activity and hard disk
drive activity. Also present are a main power button and a system reset button.
Cooling System
The chassis' revolutionary cooling design has been optimized to provide suffi cient
cooling for dual CPU confi gurations. The chassis includes four 8-cm PWM (Pulse
Width Modulated) fans located in the middle of the chassis. Fan speed is controlled
via IPMI.
1-3
SUPER SERVER 6027B-TLF User's Manual
Figure 1-1. Intel C602 Chipset:
System Block Diagram
Note: This is a general block diagram. Please see Chapter 5 for details.
RJ45
RJ45
IPMI LAN
SLOT 2
PCI-E X4
GLAN 1
82574L
GLAN 2
82574L
VGA
#C-1
#B-1
#A-1
DDR3
PCI-E X4 Gen3
in X8 slot
SLOT 6
PCI-E X16
BMC
VGA
SLOT 1
PCI-E X1 Gen2
PCI-E X1 Gen2
#1 #3 #1 DMI
800/1066/1333/1600
PCI-E X16 Gen3
PCI-E x4
PCI-E
#1
PCI-E
#1
PCI-E X1
PCI-32MHz
PCI-33MHz
PCI
CPU 1
DDR3
PEG0
SPI
BIOS
P0
DMI
4GB/s
DMI
PCH
SSB-D/A
LPC
SIO
W83527
QPI
P1
8G
#3 #3 #1
TPM
Header
CPU 2
DDR3
PCI-E X8 Gen3
PCI-E X8 Gen3
6.0 Gb/S
3.0 Gb/S for Ports 2~5
(SCU-SATA/SAS)
3.0 Gb/S
for Ports 0/1
USB 2.0
USB
#0~#6
#D-1
PCI-E X8 Gen3
PCI-E X16
SLOT 3
PCI-E X16
SAS
#0~#7
#0~#5
2 Rear
4 Front
1 Type-A
#F-1
#E-1
DDR3
800/1066/1333/1600
SLOT 5
PCI-E X16
SLOT 4
SATA
SCU-
SATA/SAS
COM1
External
1-4
COM2
Header
Chapter 1: Introduction
1-4 Contacting Supermicro
Headquarters
Address: Super Micro Computer, Inc.
980 Rock Ave.
San Jose, CA 95131 U.S.A.
Tel: +1 (408) 503-8000
Fax: +1 (408) 503-8008
Email: marketing@supermicro.com (General Information)
support@supermicro.com (Technical Support)
Web Site: www.supermicro.com
Europe
Address: Super Micro Computer B.V.
Het Sterrenbeeld 28, 5215 ML
's-Hertogenbosch, The Netherlands
Tel: +31 (0) 73-6400390
Fax: +31 (0) 73-6416525
Email: sales@supermicro.nl (General Information)
support@supermicro.nl (Technical Support)
rma@supermicro.nl (Customer Support)
Asia-Pacifi c
Address: Super Micro Computer, Inc.
4F, No. 232-1, Liancheng Rd.
Chung-Ho Dist., New Taipei City 235
Taiwan
Tel: +886-(2) 8226-3990
Fax: +886-(2) 8226-3991
Web Site: www.supermicro.com.tw
Technical Support:
Email: support@supermicro.com.tw
Tel: 886-2-8228-1366, ext.132 or 139
1-5
SUPER SERVER 6027B-TLF User's Manual
Notes
1-6
Chapter 2: Server Installation
Chapter 2
Server Installation
2-1 Overview
This chapter provides a quick setup checklist to get your SuperServer 6027B-TLF
up and running. Following these steps in the order given should enable you to have
the system operational within a minimum amount of time. This quick setup assumes
that your SuperServer 6027B-TLF system has come to you with the processors
and memory preinstalled.
2-2 Unpacking the System
You should inspect the box the SuperServer 6027B-TLF was shipped in and note
if it was damaged in any way. If the server itself shows damage you should fi le a
damage claim with the carrier who delivered it.
Decide on a suitable location for the rack unit that will hold the SuperServer 6027B-
TLF. It should be situated in a clean, dust-free area that is well ventilated. Avoid
areas where heat, electrical noise and electromagnetic fi elds are generated. You
will also need it placed near a grounded power outlet. Read the Rack and Server
Precautions in the next section.
2-3 Preparing for Setup
The box the SuperServer 6027B-TLF was shipped in should include two sets of rail
assemblies, two rail mounting brackets and the mounting screws you will need to
install the system into the rack. Follow the steps in the order given to complete the
installation process in a minimum amount of time. Please read this section in its en-
tirety before you begin the installation procedure outlined in the sections that follow.
Choosing a Setup Location
• Leave enough clearance in front of the rack to enable you to open the front door
completely (~25 inches) and approximately 30 inches of clearance in the back
of the rack to allow for suffi cient airfl ow and ease in servicing.
2-1
SUPER SERVER 6027B-TLF Manual
• This product is for installation only in a Restricted Access Location (dedicated
equipment rooms, service closets and the like).
• This product is not suitable for use with visual display work place devices
acccording to §2 of the the German Ordinance for Work with Visual Display
Units.
Warnings and Precautions!
Rack Precautions
• Ensure that the leveling jacks on the bottom of the rack are fully extended to
the fl oor with the full weight of the rack resting on them.
• In single rack installation, stabilizers should be attached to the rack. In multiple
rack installations, the racks should be coupled together.
• Always make sure the rack is stable before extending a component from the
rack.
• You should extend only one component at a time - extending two or more si-
multaneously may cause the rack to become unstable.
Server Precautions
• Review the electrical and general safety precautions in Chapter 4.
• Determine the placement of each component in the rack before you install the
rails.
• Install the heaviest server components on the bottom of the rack fi rst, and then
work up.
• Use a regulating uninterruptible power supply (UPS) to protect the server from
power surges, voltage spikes and to keep your system operating in case of a
power failure.
2-2
Chapter 2: Server Installation
• Allow any hot plug drives and power supply modules to cool before touching
them.
• Always keep the rack's front door and all panels and components on the servers
closed when not servicing to maintain proper cooling.
Rack Mounting Considerations
Ambient Operating Temperature
If installed in a closed or multi-unit rack assembly, the ambient operating tempera-
ture of the rack environment may be greater than the ambient temperature of the
room. Therefore, consideration should be given to installing the equipment in an
environment compatible with the manufacturer’s maximum rated ambient tempera-
ture (Tmra).
Reduced Airfl ow
Equipment should be mounted into a rack so that the amount of airfl ow required
for safe operation is not compromised.
Mechanical Loading
Equipment should be mounted into a rack so that a hazardous condition does not
arise due to uneven mechanical loading.
Circuit Overloading
Consideration should be given to the connection of the equipment to the power
supply circuitry and the effect that any possible overloading of circuits might have
on overcurrent protection and power supply wiring. Appropriate consideration of
equipment nameplate ratings should be used when addressing this concern.
Reliable Ground
A reliable ground must be maintained at all times. To ensure this, the rack itself
should be grounded. Particular attention should be given to power supply connec-
tions other than the direct connections to the branch circuit (i.e. the use of power
strips, etc.).
2-3
SUPER SERVER 6027B-TLF Manual
2-4 Installing the System into a Rack
This section provides information on installing the SuperServer 6027B-TLF into a
rack unit. If the 6027B-TLF has already been mounted into a rack, you can skip
ahead to Sections 2-5 and 2-6. There are a variety of rack units on the market, which
may mean the assembly procedure will differ slightly. The following is a guideline
for installing the 6027B-TLF into a rack with the rack rails provided. You should
also refer to the installation instructions that came with the rack unit you are using.
Identifying the Sections of the Rack Rails
You should have received two rack rail assemblies with the SuperServer 6027B-TLF.
Each of these assemblies consist of three sections: an inner fi xed chassis rail that
secures to the 6027B-TLF (A) and an outer fi xed rack rail that secures directly to
the rack itself (B). A sliding rail guide sandwiched between the two should remain
attached to the fi xed rack rail (see Figure 2-1). The A and B rails must be detached
from each other to install.
To remove the fi xed chassis rail (A), pull it out as far as possible - you should hear
a "click" sound as a locking tab emerges from inside the rail assembly and locks
the inner rail. Then depress the locking tab to pull the inner rail completely out. Do
this for both the left and right side rack rail assemblies.
Figure 2-1. Identifying the Sections of the Rack Rails
B
A
2-4
Chapter 2: Server Installation
Installing the Chassis Rails
Position one of the fi xed chassis rail sections you just removed along the side of the
6027B-TLF. Note that these two rails are left/right specifi c. Slide the rail toward the
front of the chassis (see arrows in Figure 2-2) until you hear them click into place
with the retention hooks on the chassis. The screw holes should now be aligned -
screw the rail securely to the side of the chassis (see Figure 2-2).
Repeat this procedure for the other rail on the other side of the chassis. You will
also need to attach the rail brackets when installng into a telco rack.
Locking Tabs: As you have seen, both chassis rails have a locking tab, which
serves two functions. The fi rst is to lock the server into place when installed and
pushed fully into the rack, which is its normal position. Secondly, these tabs also
lock the server in place when fully extended from the rack. This prevents the server
from coming completely out of the rack when you pull it out for servicing.
Figure 2-2. Installing Chassis Rails
Installing the Rack Rails
Determine where you want to place the SuperServer 6027B-TLF in the rack. (See
Rack and Server Precautions in Section 2-3.) Position the fi xed rack rail/sliding rail
guide assemblies at the desired location in the rack, keeping the sliding rail guide
facing the inside of the rack. Screw the assembly securely to the rack using the
brackets provided. Attach the other assembly to the other side of the rack, mak-
ing sure both are at the exact same height and with the rail guides facing inward.
2-5
SUPER SERVER 6027B-TLF Manual
Installing the Server into the Rack
You should now have rails attached to both the chassis and the rack unit. The next
step is to install the server into the rack. Do this by lining up the rear of the chassis
rails with the front of the rack rails. Slide the chassis rails into the rack rails, keeping
the pressure even on both sides (you may have to depress the locking tabs when
inserting). See Figure 2-3.
When the server has been pushed completely into the rack, you should hear the
locking tabs "click". Finish by inserting and tightening the thumbscrews that hold
the front of the server to the rack.
Figure 2-3. Installing the Server into a Rack
2-6
Chapter 2: Server Installation
Installing the Server into a Telco Rack
If you are installing the SuperServer 6027B-TLF into a Telco type rack, follow the
directions given on the previous pages for rack installation. The only difference in the
installation procedure will be the positioning of the rack brackets to the rack. They
should be spaced apart just enough to accommodate the width of the telco rack.
Figure 2-4. Installing the Server into a Telco Rack
Note: fi gures are for illustrative purposes only. Servers should always be installed
in racks from the bottom up.
2-7
SUPER SERVER 6027B-TLF Manual
Notes
2-8
Chapter 3: System Interface
Chapter 3
System Interface
3-1 Overview
There are several LEDs on the control panel as well as others on the drive carri-
ers to keep you constantly informed of the overall status of the system as well as
the activity and health of specifi c components. There are also two buttons on the
chassis control panel.
3-2 Control Panel Buttons
There are two buttons located on the front of the chassis: a reset button and a
power on/off button.
Reset
Use the reset button to reboot the system.
Power
This is the main power button, which is used to apply or turn off the main system
power. Turning off system power with this button removes the main power but keeps
standby power supplied to the system. For this reason you should also unplug the
AC power cord prior to servicing the system.
3-1
SUPERSERVER 6027B-TLF User's Manual
3-3 Control Panel LEDs
The control panel located on the front of the SC823 chassis has fi ve LEDs. These
LEDs provide you with critical information related to different parts of the system.
This section explains what each LED indicates when illuminated and any correc-
tive action you may need to take.
Power
Indicates power is being supplied to the system's power supply units. This LED
should normally be illuminated when the system is operating.
HDD
Indicates SATA drive and/or DVD-ROM drive activity when fl ashing.
NIC1
Indicates network activity on LAN1 when fl ashing.
NIC2
Indicates network activity on LAN2 when fl ashing.
3-2
Chapter 3: System Interface
Information LED
This LED will be solid blue when the UID function has been activated. When this
LED fl ashes red, it indicates a fan failure. When red continuously it indicates an
overheat condition, which may be caused by cables obstructing the airfl ow in the
system or the ambient room temperature being too warm. Check the routing of
the cables and make sure all fans are present and operating normally. You should
also check to make sure that the chassis covers are installed. Finally, verify that
the heatsinks are installed properly (see Chapter 5). This LED will remain fl ashing
or on as long as the indicated condition exists.
3-4 Drive Carrier LEDs
Each drive carrier has two LEDs:
SATA Drives
• Green: When illuminated, the green LED on the SATA drive carrier indicates
drive activity. A connection to the SATA backplane enables this LED to blink
on and off when that particular drive is being accessed. Please refer to Chapter
6 for instructions on replacing failed SATA drives.
• Red: When this LED fl ashes it indicates the drive is rebuilding. When solid on
it indicates a SATA drive failure. If a drive fails, you should be notifi ed by your
system management software. Please refer to Chapter 6 for instructions on
replacing failed drives.
3-3
SUPERSERVER 6027B-TLF User's Manual
Notes
3-4
Chapter 4: System Safety
Chapter 4
System Safety
4-1 Electrical Safety Precautions
Basic electrical safety precautions should be followed to protect yourself from harm
and the SuperServer 6027B-TLF from damage. A complete list of safety warnings
is provided on the Supermicro web site at http://super-dev/about/policies/safety_in-
formation.cfm
• Be aware of the locations of the power on/off switch on the chassis as well
as the room's emergency power-off switch, disconnection switch or electrical
outlet. If an electrical accident occurs, you can then quickly remove power from
the system.
• Do not work alone when working with high voltage components.
• Power should always be disconnected from the system when removing or in-
stalling main system components, such as the serverboard, memory modules
and fl oppy drive. When disconnecting power, you should fi rst power down the
system with the operating system fi rst and then unplug the power cords of all
the power supply units in the system.
• When working around exposed electrical circuits, another person who is familiar
with the power-off controls should be nearby to switch off the power if neces-
sary.
• Use only one hand when working with powered-on electrical equipment. This
is to avoid making a complete circuit, which will cause electrical shock. Use
extreme caution when using metal tools, which can easily damage any electrical
components or circuit boards they come into contact with.
• Do not use mats designed to decrease static electrical discharge as protection
from electrical shock. Instead, use rubber mats that have been specifi cally
designed as electrical insulators.
• The power supply power cords must include a grounding plug and must be
plugged into grounded electrical outlets.
4-1
SUPER SERVER 6027B-TLF User's Manual
• This product may be connected to an IT power system. In all cases, make sure
that the unit is also reliably connected to Earth (ground).
• Serverboard Battery: CAUTION - There is a danger of explosion if the onboard
battery is installed upside down, which will reverse its polarites (see Figure 4-1).
This battery must be replaced only with the same or an equivalent type recom-
mended by the manufacturer (CR2032). Dispose of used batteries according to
the manufacturer's instructions.
• DVD-ROM Laser: CAUTION - this server may have come equipped with a
DVD-ROM drive. To prevent direct exposure to the laser beam and hazardous
radiation exposure, do not open the enclosure or use the unit in any uncon-
ventional way.
• Mainboard replaceable soldered-in fuses: Self-resetting PTC (Positive Tempera-
ture Coeffi cient) fuses on the mainboard must be replaced by trained service
technicians only. The new fuse must be the same or equivalent as the one
replaced. Contact technical support for details and support.
4-2 General Safety Precautions
Follow these rules to ensure general safety:
• Keep the area around the 6027B-TLF clean and free of clutter.
• The 6027B-TLF weighs approximately 42 lbs. (19.09 kg.) when fully loaded.
When lifting the system, two people at either end should lift slowly with their
feet spread out to distribute the weight. Always keep your back straight and lift
with your legs.
• Place the chassis top cover and any system components that have been re-
moved away from the system or on a table so that they won't accidentally be
stepped on.
• While working on the system, do not wear loose clothing such as neckties and
unbuttoned shirt sleeves, which can come into contact with electrical circuits or
be pulled into a cooling fan.
4-2
Chapter 4: System Safety
• Remove any jewelry or metal objects from your body, which are excellent metal
conductors that can create short circuits and harm you if they come into contact
with printed circuit boards or areas where power is present.
• After accessing the inside of the system, close the system back up and secure
it to the rack unit with the retention screws after ensuring that all connections
have been made.
4-3 ESD Precautions
Electrostatic Discharge (ESD) is generated by two objects with different electrical
charges coming into contact with each other. An electrical discharge is created to
neutralize this difference, which can damage electronic com ponents and printed
circuit boards. The following measures are generally suffi cient to neutralize this
difference before contact is made to protect your equipment from ESD:
• Use a grounded wrist strap designed to prevent static discharge.
• Keep all components and printed circuit boards (PCBs) in their antistatic bags
until ready for use.
• Touch a grounded metal object before removing the board from the antistatic
bag.
• Do not let components or PCBs come into contact with your clothing, which may
retain a charge even if you are wearing a wrist strap.
• Handle a board by its edges only; do not touch its components, peripheral chips,
memory modules or contacts.
• When handling chips or modules, avoid touching their pins.
• Put the serverboard and peripherals back into their antistatic bags when not
in use.
• For grounding purposes, make sure your computer chassis provides excellent
conductivity between the power supply, the case, the mounting fasteners and
the serverboard.
4-3
SUPER SERVER 6027B-TLF User's Manual
4-4 Operating Precautions
Care must be taken to assure that the chassis cover is in place when the 6027B-
TLF is operating to assure proper cooling. Out of warranty damage to the system
can occur if this practice is not strictly followed.
Figure 4-1. Installing the Onboard Battery
LTUM BTTER
BTTER OLER
Please handle used batteries carefully. Do not damage the battery in any way; a
damaged battery may release hazardous materials into the environment. Do not
discard a used battery in the garbage or a public landfi ll. Please comply with the
regulations set up by your local hazardous waste management agency to dispose
of your used battery properly.
4-4