The information in this User’s Manual has been carefully reviewed and is believed to be accurate.
The vendor assumes no responsibility for any inaccuracies that may be contained in this document,
makes no commitment to update or to keep current the information in this manual, or to notify any
person or organization of the updates. Please Note: For the most up-to-date version of this
manual, please see our web site at www.supermicro.com.
Super Micro Computer, Inc. ("Supermicro") reserves the right to make changes to the product
described in this manual at any time and without notice. This product, including software and documentation, is the property of Supermicro and/or its licensors, and is supplied only under a license.
Any use or reproduction of this product is not allowed, except as expressly permitted by the terms
of said license.
IN NO EVENT WILL SUPERMICRO BE LIABLE FOR DIRECT, INDIRECT , SPECIAL, INCIDENTAL,
SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO
USE THIS PRODUCT OR DOCUMENTATION, EVEN IF ADVISED OF THE POSSIBILITY OF
SUCH DAMAGES. IN PARTICULAR, SUPERMICRO SHALL NOT HAVE LIABILITY FOR ANY
HARDWARE, SOFTW ARE, OR DA TA STORED OR USED WITH THE PRODUCT, INCLUDING THE
COSTS OF REPAIRING, REPLACING, INTEGRATING, INSTALLING OR RECOVERING SUCH
HARDWARE, SOFTWARE, OR DATA.
Any disputes arising between manufacturer and customer shall be governed by the laws of Santa
Clara County in the State of California, USA. The State of California, County of Santa Clara shall
be the exclusive venue for the resolution of any such disputes. Super Micro's total liability for all
claims will not exceed the price paid for the hardware product.
FCC Statement: This equipment has been tested and found to comply with the limits for a Class A
digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the manufacturer’s instruction manual, may cause harmful interference
with radio communications. Operation of this equipment in a residential area is likely to cause harmful
interference, in which case you will be required to correct the interference at your own expense.
California Best Management Practices Regulations for Perchlorate Materials: This Perchlorate warning applies only to products containing CR (Manganese Dioxide) Lithium coin cells. “Perchlorate
Material-special handling may apply. See www.dtsc.ca.gov/hazardouswaste/perchlorate”
WARNING: Handling of lead solder materials used in this
product may expose you to lead, a chemical known to the
State of California to cause birth defects and other reproductive harm.
Manual Revision 1.0
Release Date: September 17, 2010
Unless you request and receive written permission from Super Micro Computer, Inc., you may not
copy any part of this document.
Information in this document is subject to change without notice. Other products and companies
referred to herein are trademarks or registered trademarks of their respective companies or mark
holders.
This manual is written for professional system integrators and PC technicians. It
provides information for the installation and use of the SuperServer 6026T-TF. Installation and maintainance should be performed by experienced technicians only.
The SuperServer 6026T-TF is a high-end server based on the SC823TQ-650LPB
2U rackmount chassis and the X8DTE-F dual processor serverboard.
Manual Organization
Chapter 1: Introduction
Preface
The fi rst chapter provides a checklist of the main components included with the
server system and describes the main features of the X8DTE-F serverboard and
the SC823TQ-650LPB chassis.
Chapter 2: Server Installation
This chapter describes the steps necessary to install the SuperServer 6026T-TF
into a rack and check out the server confi guration prior to powering up the system.
If your server was ordered without processor and memory components, this chapter
will refer you to the appropriate sections of the manual for their installation.
Chapter 3: System Interface
Refer here for details on the system interface, which includes the functions and
information provided by the control panel on the chassis as well as other LEDs
located throughout the system.
Chapter 4: System Safety
You should thoroughly familiarize yourself with this chapter for a general overview
of safety precautions that should be followed when installing and servicing the
SuperServer 6026T-TF.
iii
SUPERSERVER 6026T-TF User's Manual
Chapter 5: Advanced Serverboard Setup
Chapter 5 provides detailed information on the X8DTE-F serverboard, including the
locations and functions of connections, headers and jumpers. Refer to this chapter
when adding or removing processors or main memory and when reconfi guring the
serverboard.
Chapter 6: Advanced Chassis Setup
Refer to Chapter 6 for detailed information on the SC823TQ-650LPB server chassis.
You should follow the procedures given in this chapter when installing, removing or
reconfi guring SATA or peripheral drives and when replacing system power supply
units and cooling fans.
Chapter 7: BIOS
The BIOS chapter includes an introduction to BIOS and provides detailed information on running the CMOS Setup Utility.
Appendix A BIOS Error Beep Codes
Appendix B Installing Windows
Appendix C System Specifi cations
viii
Chapter 1: Introduction
Chapter 1
Introduction
1-1 Overview
The SuperServer 6026T-TF is a high-end server comprised of two main subsystems: the SC823TQ-650LPB 2U server chassis and the X8DTE-F dual processor
serverboard. Please refer to our web site for information on operating systems that
have been certifi ed for use with the system (www.supermicro.com).
In addition to the serverboard and chassis, various hardware components have
been included with the 6026T-TF, as listed below:
Two passive CPU heatsinks (SNK-P0038P)
•
One slim DVD-ROM drive (DVM-TEAC-24B)•
Four 8-cm chassis fans (FAN-0094L4)•
One air shroud (MCP-310-28002-0N)•
SATA Accessories •
One SAS/SATA backplane (BPN-SAS-823TQ)
Three 35-cm SATA cables (CBL-0061L)
Three 48-cm SATA cables (CBL-0178L)
Two SGPIO cables (CBL-0157L)
Six drive carriers (CSE-PT17L-BOEM)
One rackmount kit (CSE-PT25)
•
One CD containing drivers and utilities•
SuperServer 6026T-TF User's Manual•
1-1
SUPERSERVER 6026T-TF User's Manual
1-2 Serverboard Features
The SuperServer 6026T-TF is built around the X8DTE-F, a dual processor
serverboard based on the Intel IOH-36D + ICH10R chipset and designed to provide
maximum performance. Below are the main features of the X8DTE-F. (See Figure
1-1 for a block diagram of the chipset).
Processors
The X8DTE-F supports single or dual Intel® Xeon 5600/5500 Series processors and
future Intel Nehalem processor families (next generation Intel Xeon® processor).
Please refer to the serverboard description pages on our web site for a complete
listing of supported processors (www.supermicro.com).
Memory
The X8DTE-F has twelve DIMM slots that can support up to 192 GB of ECC registered DDR3-1333/1066/800 or up to 48 GB of ECC unbuffered DDR3-1333/1066/800
SDRAM. Memory mirroring is supported. See Chapter 5 for details.
Serial ATA
A Serial ATA controller is integrated into the ICH10R (South Bridge) portion of the
IOH-36D chipset to provide a six-port 3 Gb/s SATA subsystem, which is RAID 0, 1,
10 and 5 supported. The SATA drives are hot-swappable units.
Note: The operati ng system yo u use must h ave R AID su ppor t to e nable t he hotswap cap abilit y and RA ID func tion of the S ATA drives. R AI D 5 requires t he use
of an iButton.
PCI Expansion Slots
The X8DTE- F has four PCI Express 2.0 x8 slots, one PCI Express 2.0 x4 slot and
one PCI Express x4 slot.
Onboard Controllers/Ports
A fl oppy drive connector is included on the serverboard. The color-coded I/O ports
include one COM port (an additional COM header is located on the serverboard), a
VGA (monitor) port, two USB 2.0 ports (additional USB headers are included on the
serverboard), PS/2 mouse and keyboard ports and two gigabit Ethernet ports.
1-2
Chapter 1: Introduction
Graphics Controller
The X8DTE-F features an integrated Matrox G200eW video controller. The
G200eW is a 2D/3D/video accelerator chip with a 128-bit core and 16 MB of DDR2
memory.
Other Features
Other onboard features that promote system health include onboard voltage monitors, a chassis intrusion header, auto-switching voltage regulators, chassis and CPU
overheat sensors, virus protection and BIOS rescue.
1-3 Server Chassis Features
The following is a general outline of the main features of the SC823TQ-650LPB
server chassis.
System Power
The SC823TQ-650LPB features a redundant 650W power supply composed of two
separate power modules. This power redundancy feature allows you to replace a
failed power supply without shutting down the system.
SATA Subsystem
The SC823TQ-650LPB supports up to six SATA drives. These drives are
hot-swappable units and are connected to a backplane that provides power and
control.
Note: The operating system you use must have RAID support to enable the hotswap capability of the SATA drives.
Front Control Panel
The control panel on the SuperServer 6026T-TF provides you with system monitoring and control. LEDs indicate system power, HDD activity, network activity, system
overheat and power supply failure. A main power button and a system reset button
are also included.
I/O Backplane
The SC823TQ-650LPB is an ATX form factor chassis designed to be used in a 2U
rackmount confi guration. The I/O backplane provides seven low-profi le add-on card
1-3
SUPERSERVER 6026T-TF User's Manual
slots, one COM port, a VGA port, two USB 2.0 ports, PS/2 mouse and keyboard
ports and two gigabit Ethernet ports.
Cooling System
The SC823TQ-650LPB chassis has an innovative cooling design that includes four
8-cm system cooling fans. The fans plug into chassis fan connectors that are located
behind the drive bays. A "Fan Speed Control Mode" setting in BIOS allows the user
to set the chassis fan speed. If any fan fails and the ambient air temperature inside
the chassis becomes too high, an overheat LED and alarm will be activated. The
system also includes an air shroud to maximize airfl ow effi ciency.
1-4
Chapter 1: Introduction
Figure 1-1. Intel IOH-36D/ICH10R Chipset:
System Block Diagram
Note: This is a general block diagram. Please see Chapter 5 for details.
Tel: +886-(2) 8226-3990
Fax: +886-(2) 8226-3991
Web Site:www.supermicro.com.tw
Technical Support:
Email:support@supermicro.com.tw
Tel: 886-2-8228-1366, ext.132 or 139
1-6
Chapter 2: Server Installation
Chapter 2
Server Installation
2-1 Overview
This chapter provides a quick setup checklist to get your SuperServer 6026T-TF up
and running. Following these steps in the order given should enable you to have
the system operational within a minimum amount of time. This quick setup assumes
that your SuperServer 6026T-TF system has come to you with the processors and
memory preinstalled. If your system is not already fully integrated with a motherboard, processors, system memory etc., please turn to the chapter or section noted
in each step for details on installing specifi c components.
2-2 Unpacking the System
You should inspect the box the SuperServer 6026T-TF was shipped in and note
if it was damaged in any way. If the server itself shows damage you should fi le a
damage claim with the carrier who delivered it.
Decide on a suitable location for the rack unit that will hold the SuperServer 6026TTF. It should be situated in a clean, dust-free area that is well ventilated. Avoid
areas where heat, electrical noise and electromagnetic fi elds are generated. You
will also need it placed near a grounded power outlet. Read the Rack and Server
Precautions in the next section.
2-3 Preparing for Setup
The box the SuperServer 6026T-TF was shipped in should include two sets of rail
assemblies, two rail mounting brackets and the mounting screws you will need to
install the system into the rack. Follow the steps in the order given to complete
the installation process in a minimum amount of time. Please read this section in
its entirety before you begin the installation procedure outlined in the sections that
follow.
Choosing a Setup Location
2-1
SUPERSERVER 6026T-TF Manual
!
!
Leave enough clearance in front of the rack to enable you to open the front door •
completely (~25 inches) and approximately 30 inches of clearance in the back
of the rack to allow for suffi cient airfl ow and ease in servicing.
This product is for installation only in a Restricted Access Location (dedicated
•
equipment rooms, service closets and the like).
This product is not suitable for use with visual display work place devices
•
acccording to §2 of the the German Ordinance for Work with Visual Display
Units.
Warnings and Precautions!
Rack Precautions
Ensure that the leveling jacks on the bottom of the rack are fully extended to •
the fl oor with the full weight of the rack resting on them.
In single rack installation, stabilizers should be attached to the rack. In multiple
•
rack installations, the racks should be coupled together.
•
Always make sure the rack is stable before extending a component from the
rack.
You should extend only one component at a time - extending two or more si-
•
multaneously may cause the rack to become unstable.
Server Precautions
Review the electrical and general safety precautions in Chapter 4.•
Determine the placement of each component in the rack • before you install the
rails.
Install the heaviest server components on the bottom of the rack fi rst, and then
•
work up.
Use a regulating uninterruptible power supply (UPS) to protect the server from
•
power surges, voltage spikes and to keep your system operating in case of a
power failure.
2-2
Chapter 2: Server Installation
Allow any hot plug drives and power supply modules to cool before touching •
them.
Always keep the rack's front door and all panels and components on the servers
•
closed when not servicing to maintain proper cooling.
Rack Mounting Considerations
Ambient Operating Temperature
If installed in a closed or multi-unit rack assembly, the ambient operating temperature of the rack environment may be greater than the ambient temperature of the
room. Therefore, consideration should be given to installing the equipment in an
environment compatible with the manufacturer’s maximum rated ambient temperature (Tmra).
Reduced Airfl ow
Equipment should be mounted into a rack so that the amount of airfl ow required
for safe operation is not compromised.
Mechanical Loading
Equipment should be mounted into a rack so that a hazardous condition does not
arise due to uneven mechanical loading.
Circuit Overloading
Consideration should be given to the connection of the equipment to the power
supply circuitry and the effect that any possible overloading of circuits might have
on overcurrent protection and power supply wiring. Appropriate consideration of
equipment nameplate ratings should be used when addressing this concern.
Reliable Ground
A reliable ground must be maintained at all times. To ensure this, the rack itself
should be grounded. Particular attention should be given to power supply connections other than the direct connections to the branch circuit (i.e. the use of power
strips, etc.).
2-3
SUPERSERVER 6026T-TF Manual
2-4 Installing the System into a Rack
This section provides information on installing the SuperServer 6026T-TF into a rack
unit. If the 6026T-TF has already been mounted into a rack, you can skip ahead to
Sections 2-5 and 2-6. There are a variety of rack units on the market, which may
mean the assembly procedure will differ slightly. The following is a guideline for
installing the 6026T-TF into a rack with the rack rails provided. You should also refer
to the installation instructions that came with the rack unit you are using.
Identifying the Sections of the Rack Rails
You should have received two rack rail assemblies with the SuperServer 6026T-TF.
Each of these assemblies consist of three sections: an inner fi xed chassis rail that
secures to the 6026T-TF (A) and an outer fi xed rack rail that secures directly to
the rack itself (B). A sliding rail guide sandwiched between the two should remain
attached to the fi xed rack rail (see Figure 2-1). The A and B rails must be detached
from each other to install.
To remove the fi xed chassis rail (A), pull it out as far as possible - you should hear
a "click" sound as a locking tab emerges from inside the rail assembly and locks
the inner rail. Then depress the locking tab to pull the inner rail completely out. Do
this for both the left and right side rack rail assemblies.
Figure 2-1. Identifying the Sections of the Rack Rails
B
A
2-4
Chapter 2: Server Installation
Installing the Chassis Rails
Position one of the fi xed chassis rail sections you just removed along the side of the
6026T-TF. Note that these two rails are left/right specifi c. Slide the rail toward the
front of the chassis (see arrows in Figure 2-2) until you hear them click into place
with the retention hooks on the chassis. The screw holes should now be aligned screw the rail securely to the side of the chassis (see Figure 2-2).
Repeat this procedure for the other rail on the other side of the chassis. You will
also need to attach the rail brackets when installng into a telco rack.
Locking Tabs: As you have seen, both chassis rails have a locking tab, which
serves two functions. The fi rst is to lock the server into place when installed and
pushed fully into the rack, which is its normal position. Secondly, these tabs also
lock the server in place when fully extended from the rack. This prevents the server
from coming completely out of the rack when you pull it out for servicing.
Figure 2-2. Installing Chassis Rails
Installing the Rack Rails
Determine where you want to place the SuperServer 6026T-TF in the rack. (See
Rack and Server Precautions in Section 2-3.) Position the fi xed rack rail/sliding rail
guide assemblies at the desired location in the rack, keeping the sliding rail guide
facing the inside of the rack. Screw the assembly securely to the rack using the
brackets provided. Attach the other assembly to the other side of the rack, making
sure both are at the exact same height and with the rail guides facing inward.
2-5
SUPERSERVER 6026T-TF Manual
Installing the Server into the Rack
You should now have rails attached to both the chassis and the rack unit. The next
step is to install the server into the rack. Do this by lining up the rear of the chassis
rails with the front of the rack rails. Slide the chassis rails into the rack rails, keeping
the pressure even on both sides (you may have to depress the locking tabs when
inserting). See Figure 2-3.
When the server has been pushed completely into the rack, you should hear the
locking tabs "click". Finish by inserting and tightening the thumbscrews that hold
the front of the server to the rack.
Figure 2-3. Installing the Server into a Rack
2-6
Chapter 2: Server Installation
Installing the Server into a Telco Rack
If you are installing the SuperServer 6026T-TF into a Telco type rack, follow the
directions given on the previous pages for rack installation. The only difference in the
installation procedure will be the positioning of the rack brackets to the rack. They
should be spaced apart just enough to accommodate the width of the telco rack.
Figure 2-4. Installing the Server into a Telco Rack
2-7
SUPERSERVER 6026T-TF Manual
2-5 Checking the Motherboard Setup
After you install the 6026T-TF in the rack, you will need to open the unit to make sure
the motherboard is properly installed and all the connections have been made.
Accessing the Inside of the System (see Figure 2-5)
Grasp the two handles on either side and pull the unit straight out until it 1.
locks (you will hear a "click").
Next, depress the two buttons on the top of the chassis to release the top 2.
cover. There is a large rectangular recess in the middle front of the top cover
to help you push the cover away from you until it stops.
Lift the top cover from the chassis to gain full access to the inside of the 3.
server.
Checking the Components and Setup
You may have one or two processors already installed into the serverboard. 1.
Each processor needs its own heat sink. See Chapter 5 for instructions on
processor and heat sink installation.
Your server may have come with system memory already installed. Make 2.
sure all DIMMs are fully seated in their slots. For details on adding system
memory, refer to Chapter 5.
If desired, you can install add-on cards to the system. See Chapter 5 for 3.
details on installing PCI add-on cards.
Make sure all power and data cables are properly connected and not blocking 4.
the chassis airfl ow. Also make sure that no cables are positioned in front of
the fans. See Chapter 5 for details on cable connections.
2-8
Chapter 2: Server Installation
Figure 2-5. Accessing the Inside of the System
Release buttons
2-9
SUPERSERVER 6026T-TF Manual
2-6 Checking the Drive Bay Setup
Next, you should check to make sure the peripheral drives and the SATA drives
have been properly installed and all connections have been made.
Checking the Drives
All drives are accessable from the front of the server. For servicing the DVD-1.
ROM, you will need to remove the top chassis cover. The hard drives can be
installed and removed from the front of the chassis without removing the top
chassis cover.
A slim DVD-ROM may be preinstalled in your server. Refer to Chapter 6 if 2.
you need to install a DVD-ROM drive to the system.
Depending upon your system's confi guration, your system may have one or 3.
more drives already installed. If you need to install hard drives, please refer to
Chapter 6.
Checking the Airfl ow
Airfl ow is provided by four hot-swappable 8-cm chassis cooling fans. The 1.
system component layout was carefully designed to direct suffi cient cooling
airfl ow to the components that generate the most heat.
Note that all power and data cables have been routed in such a way that they 2.
do not block the airfl ow generated by the fans.
Providing Power
Plug the power cord(s) from the power supply unit(s) into a high-quality power 1.
strip that offers protection from electrical noise and power surges. It is recommended that you use an uninterruptible power supply (UPS).
Depress the power on button on the front of the chassis. 2.
2-10
Chapter 3: System Interface
Chapter 3
System Interface
3-1 Overview
There are several LEDs on the control panel as well as others on the drive carriers to keep you constantly informed of the overall status of the system as well as
the activity and health of specifi c components. There are also two buttons on the
chassis control panel.
3-2 Control Panel Buttons
There are two buttons located on the front of the chassis: a reset button and a
power on/off button.
Reset
Use the reset button to reboot the system.
Power
This is the main power button, which is used to apply or turn off the main system
power. T urning off system power with this button removes the main power but keeps
standby power supplied to the system. For this reason you should also unplug the
AC power cord prior to servicing the system.
3-1
SUPERSERVER 6026T-TF User's Manual
3-3 Control Panel LEDs
The control panel located on the front of the SC823 chassis has fi ve LEDs. These
LEDs prov ide yo u wi th c r iti c al inf or mat io n re lated t o differe nt parts of t he syst em.
This sec tion ex plains w hat each L ED indic ates wh en illum inated an d any cor rec tive action you may need to take.
Power:• Indic ates powe r is bein g suppl ied to th e system's p ower sup ply unit s.
This LED should normally be illuminated when the system is operating.
HDD:
• Indic ates SATA drive and/or DV D- ROM dr ive act ivit y when fl ashing.
• I ndic ates net work ac tivit y on L AN 2 when fl ashing.
NIC2:
NIC1:• Indica tes net work ac tivit y on L AN1 when fl ashing.
3-2
Overheat/Fan Fail:• When this LED fl ashes it indicates a fan failure. When
continuously on (not fl ashin g) it indi cates an over h eat condi t ion, whic h m ay b e
caused by cables obstructing the airfl ow i n the system or the a mbient room
temperat ure being to o warm. Che ck the rou ting of the c ables an d make sure
all fans ar e present and ope rating norma lly. You should a lso check to make
sure that t he c ha s si s c over s ar e in st al le d. Fin al ly, verify that th e he ats in ks ar e
instal led p rop er ly. This LED w ill r ema in fl ashing or on as long as the overheat
condition exists.
3-4 Drive Carrier LEDs
Chapter 3: System Interface
Each drive carrier has two LEDs:
SATA Drives
Green:• When ill uminated, the green LED on the SATA drive carr ier indic ates
drive ac tivity. A con nectio n to the SATA backplan e enables t his LED to blink
on and off when that particular drive is being accessed. Please refer to Chapter
6 for instructions on replacing failed SATA drives.
Red:
• When this LED fl ashes it indicates the drive is rebuilding. When solid on
it indicates a SATA drive failure. If a drive fails, you should be notifi ed by your
system management software. Please refer to Chapter 6 for instructions on
replacing failed drives.
3-3
SUPERSERVER 6026T-TF User's Manual
Notes
3-4
Chapter 4: System Safety
!
Chapter 4
System Safety
4-1 Electrical Safety Precautions
Basic electrical safety precautions should be followed to protect yourself from harm
and the SuperServer 6026T-TF from damage:
Be aware of the locations of the power on/off switch on the chassis as well
•
as the room's emergency power-off switch, disconnection switch or electrical
outlet. If an electrical accident occurs, you can then quickly remove power from
the system.
Do not work alone when working with high voltage components.
•
Power should always be disconnected from the system when removing or install-•
ing main system components, such as the serverboard, memory modules and
fl oppy drive. When disconnecting power, you should fi rst power down the system
with the operating system. The unit may have more than one power supply cord.
Disconnect both power supply cords before servicing to avoid electrical shock.
When working around exposed electrical circuits, another person who is familiar
•
with the power-off controls should be nearby to switch off the power if necessary.
Use only one hand when working with powered-on electrical equipment. This
•
is to avoid making a complete circuit, which will cause electrical shock. Use
extreme caution when using metal tools, which can easily damage any electrical
components or circuit boards they come into contact with.
Do not use mats designed to decrease static electrical discharge as protection
•
from electrical shock. Instead, use rubber mats that have been specifi cally
designed as electrical insulators.
The power supply power cords must include a grounding plug and must be
•
plugged into grounded electrical outlets.
4-1
SUPERSERVER 6026T-TF User's Manual
!
This product may be connected to an IT power system. In all cases, make sure •
that the unit is also reliably connected to Earth (ground).
Serverboard Battery:
• CAUTION - There is a danger of explosion if the onboard
battery is installed upside down, which will reverse its polarites (see Figure 4-1).
This battery must be replaced only with the same or an equivalent type recommended by the manufacturer (CR2032). Dispose of used batteries according to
the manufacturer's instructions.
DVD-ROM Laser:
• CAUTION - this server may have come equipped with a
DVD-ROM drive. To prevent direct exposure to the laser beam and hazardous
radiation exposure, do not open the enclosure or use the unit in any unconventional way.
ture Coeffi cient) fuses on the mainboard must be replaced by trained service
technicians only. The new fuse must be the same or equivalent as the one
replaced. Contact technical support for details and support.
4-2 General Safety Precautions
Follow these rules to ensure general safety:
Keep the area around the 6026T-TF clean and free of clutter.
•
The 6026T-TF weighs approximately 55 lbs (25 kg.) when fully loaded. When •
lifting the system, two people at either end should lift slowly with their feet
spread out to distribute the weight. Always keep your back straight and lift with
your legs.
Place the chassis top cover and any system components that have been re-
•
moved away from the system or on a table so that they won't accidentally be
stepped on.
While working on the system, do not wear loose clothing such as neckties and
•
unbuttoned shirt sleeves, which can come into contact with electrical circuits or
be pulled into a cooling fan.