Supero SuperServer 6024H-82, SuperServer 6024H-82R, SuperServer 6024H-i2 User Manual

®
SUPERSERVER 6024H-82R SUPERSERVER 6024H-82R+ SUPERSERVER 6024H-82 SUPERSERVER 6024H-i2
USER’S MANUAL
1.0b
The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccuracies that may be contained in this document, makes no commitment to update or to keep current the information in this manual, or to notify any person or organization of the updates.
Please Note: For the most up-to-date version of this manual, please see our web site at www.supermicro.com.
SUPERMICRO COMPUTER reserves the right to make changes to the product described in this manual at any time and without notice. This product, including software, if any, and documentation may not, in whole or in part, be copied, photocopied, reproduced, translated or reduced to any medium or machine without prior written consent.
IN NO EVENT WILL SUPERMICRO COMPUTER BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL, SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO USE THIS PRODUCT OR DOCUMENTATION, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. IN PARTICULAR, THE VENDOR SHALL NOT HAVE LIABILITY FOR ANY HARDWARE, SOFTWARE, OR DATA STORED OR USED WITH THE PRODUCT, INCLUDING THE COSTS OF REPAIRING, REPLACING, INTEGRATING, INSTALLING OR RECOVERING SUCH HARDWARE, SOFTWARE, OR DATA.
Any disputes arising between manufacturer and customer shall be governed by the laws of Santa Clara County in the State of California, USA. The State of California, County of Santa Clara shall be the exclusive venue for the resolution of any such disputes. Supermicro's total liability for all claims will not exceed the price paid for the hardware product.
Manual Revision 1.0b Release Date: December 13, 2005
Unless you request and receive written permission from SUPER MICRO COMPUTER, you may not copy any part of this document.
Information in this document is subject to change without notice. Other products and companies referred to herein are trademarks or registered trademarks of their respective companies or mark holders.
Copyright © 2005 by SUPER MICRO COMPUTER INC. All rights reserved.
Printed in the United States of America
iii
Preface
Preface
About This Manual
This manual is written for professional system integrators and PC techni­cians. It provides information for the installation and use of the SuperServer 6024H-82R/6024H-82/6024H-i2. Installation and maintainance should be per­formed by experienced technicians only.
The SuperServer 6024H-82R/6024H-82/6024H-i2 is a high-end server based on the SC823S-500RC/SC823S-550LP/SC823i-550LP 2U rackmount chassis and the Super X6DH8-G2/X6DHE-G2, a dual processor serverboard that supports Intel® XeonTM processors at a Front Side (System) Bus speed of 800 MHz and up to 16 GB of registered ECC DDR2-400 SDRAM. The 6024H-82R+ is an upgrade model to the 6024H-82R to support dual­core (Paxville) processors.
Manual Organization
Chapter 1: Introduction
The first chapter provides a checklist of the main components included with the server system and describes the main features of the X6DH8-G2/ X6DHE-G2 serverboard and the SC823S-500RC/SC823S-550LP/SC823i­550LP chassis, which comprise the SuperServer 6024H-82R/6024H-82/ 6024H-i2.
Chapter 2: Server Installation
This chapter describes the steps necessary to install the SuperServer 6024H­82R/6024H-82/6024H-i2 into a rack and check out the server configuration prior to powering up the system. If your server was ordered without processor and memory components, this chapter will refer you to the ap­propriate sections of the manual for their installation.
Chapter 3: System Interface
Refer here for details on the system interface, which includes the functions and information provided by the control panel on the chassis as well as other LEDs located throughout the system.
SUPERSERVER 6024H-82R/6024H-82/6024H-i2 User's Manual
iv
Chapter 4: System Safety
You should thoroughly familiarize yourself with this chapter for a general overview of safety precautions that should be followed when installing and servicing the SuperServer 6024H-82R/6024H-82/6024H-i2.
Chapter 5: Advanced Serverboard Setup
Chapter 5 provides detailed information on the X6DH8-G2/X6DHE-G2 serverboard, including the locations and functions of connections, headers and jumpers. Refer to this chapter when adding or removing processors or main memory and when reconfiguring the serverboard.
Chapter 6: Advanced Chassis Setup
Refer to Chapter 6 for detailed information on the SC823S-500RC/SC823S­550LP/SC823i-550LP server chassis. You should follow the procedures given in this chapter when installing, removing or reconfiguring SCSI/IDE or peripheral drives and when replacing system power supply units and cool­ing fans.
Chapter 7: BIOS
The BIOS chapter includes an introduction to BIOS and provides detailed information on running the CMOS Setup Utility.
Appendix A: BIOS POST Codes
Appendix B: Software Installation
Appendix C: System Specifications
v
Preface
Notes
vi
Table of Contents
Preface
About This Manual ...................................................................................................... iii
Manual Organization ................................................................................................... iii
Chapter 1: Introduction
1-1 Overview ......................................................................................................... 1-1
1-2 Serverboard Features ................................................................................... 1-2
1-3 Server Chassis Features.............................................................................. 1-3
1-4 Contacting Supermicro .................................................................................. 1-6
Chapter 2: Server Installation
2-1 Overview ......................................................................................................... 2-1
2-2 Unpacking the System ................................................................................... 2-1
2-3 Preparing for Setup ....................................................................................... 2-1
2- 4 Installing the System into a Rack ................................................................ 2-4
2-5 Checking the Serverboard Setup ................................................................ 2-8
2-6 Checking the Drive Bay Setup ................................................................... 2-10
Chapter 3: System Interface
3-1 Overview ......................................................................................................... 3-1
3- 2 Control Panel Buttons.................................................................................... 3-1
Power ........................................................................................................ 3-1
Reset.......................................................................................................... 3-1
3-3 Control Panel LEDs ........................................................................................ 3-2
Power Fail ................................................................................................. 3-2
Overheat/Fan Fail .................................................................................... 3-2
NIC2 ............................................................................................................ 3-2
NIC1 ............................................................................................................ 3-3
HDD ............................................................................................................ 3-3
Power ........................................................................................................ 3-3
3- 4 SCSI Drive Carrier LEDs ............................................................................... 3-3
Chapter 4: System Safety
4-1 Electrical Safety Precautions ........................................................................ 4-1
4-2 General Safety Precautions .......................................................................... 4-2
4- 3 ESD Precautions .............................................................................................. 4-3
4-4 Operating Precautions .................................................................................... 4-4
SUPERSERVER 6024H-82R/6024H-82/6024H-i2 User's Manual
Chapter 5: Advanced Serverboard Setup
5-1 Handling the Serverboard ............................................................................. 5-1
5-2 Processor and Heatsink Installation ............................................................ 5-2
5-3 Connecting Cables ......................................................................................... 5-4
Connecting Data Cables ......................................................................... 5-4
Connecting Power Cables...................................................................... 5-4
Connecting the Control Panel ................................................................ 5-5
5- 4 I/O Ports........................................................................................................... 5-6
5- 5 Installing Memory ............................................................................................ 5-6
5- 6 Adding PCI Cards ........................................................................................... 5-8
5-7 Serverboard Details ....................................................................................... 5-9
X6DH8-G2/X6DHE-G2 Layout................................................................. 5-9
X6DH8-G2/X6DHE-G2 Quick Reference ............................................ 5-10
5-8 Connector Definitions .................................................................................. 5-11
ATX Power Connector.......................................................................... 5-11
Processor Power Connector............................................................... 5-11
NMI Button ............................................................................................... 5-11
Power LED .............................................................................................. 5-11
HDD LED .................................................................................................. 5-12
NIC1/NIC2 LED ......................................................................................... 5-12
Overheat/Fan Fail LED .......................................................................... 5-12
Power Fail LED ...................................................................................... 5-12
Reset Button ........................................................................................... 5-13
Power Button .......................................................................................... 5-13
Chassis Intrusion .................................................................................... 5-13
Universal Serial Bus (USB0/1) ............................................................ 5-13
Fan Headers ........................................................................................... 5-14
Serial Ports ............................................................................................. 5-14
GLAN 1/2 (Ethernet Ports) ................................................................... 5-14
ATX PS/2 Keyboard and Mouse Ports ............................................... 5-14
Power LED/Speaker/NMI ....................................................................... 5-15
Wake-On-Ring .........................................................................................5-15
Wake-On-LAN ........................................................................................ 5-15
Power Fault ............................................................................................ 5-16
SMB .......................................................................................................... 5-16
SMB Power Connector ......................................................................... 5-16
Overheat LED ......................................................................................... 5-16
vii
Table of Contents
viii
5- 9 Jumper Settings ............................................................................................ 5-17
Explanation of Jumpers ........................................................................ 5-17
CMOS Clear............................................................................................. 5-17
GLAN Enable/Disable............................................................................. 5-18
SCSI Controller Enable/Disable ............................................................ 5-18
SCSI Termination Enable/Disable......................................................... 5-18
Watch Dog Enable/Disable ................................................................... 5-19
VGA Enable/Disable .............................................................................. 5-19
Power Force On Enable/Disable ......................................................... 5-19
Third Power Supply Alarm Enable/Disable ........................................ 5-20
Alarm Reset ............................................................................................ 5-20
5-10 Onboard Indicators ...................................................................................... 5-21
GLAN1/GLAN2 LEDs ............................................................................. 5-21
5-11 Parallel Port, Floppy/Hard Disk Drive and SCSI Connections............... 5-21
Parallel Port Connector ......................................................................... 5-21
Floppy Connector ................................................................................... 5-22
IDE Connectors ...................................................................................... 5-22
Ultra320 SCSI Connectors .................................................................... 5-23
Chapter 6: Advanced Chassis Setup
6- 1 Static-Sensitive Devices ................................................................................. 6-1
6-2 Front Control Panel ...........................................................................................6-3
6-3 System Fans .................................................................................................... 6-3
System Fan Failure ................................................................................... 6-3
Replacing System Fans ........................................................................... 6-3
6- 4 Drive Bay Installation/Removal ...................................................................... 6-4
SCSI Drives ............................................................................................... 6-5
Installing a Component in the 5.25" Drive Bays ................................. 6-7
6-5 Power Supply: 6024H-82R ............................................................................ 6-9
Power Supply Failure .............................................................................. 6-9
Removing/Replacing the Power Supply ................................................ 6-9
6-5 Power Supply: 6024H-i2.............................................................................. 6-10
Power Supply Failure ............................................................................6-10
Removing/Replacing the Power Supply .............................................. 6-10
Chapter 7: BIOS
7- 1 Introduction....................................................................................................... 7-1
7- 2 Running Setup ...................................................................................................7-2
7-3 Main BIOS Setup ..............................................................................................7-2
7-4 Advanced Setup.............................................................................................. 7-8
SUPERSERVER 6024H-82R/6024H-82/6024H-i2 User's Manual
Table of Contents
ix
7-5 Security........................................................................................................... 7-19
7- 6 Boot ................................................................................................................. 7-21
7-7 Exit ................................................................................................................... 7-22
Appendices:
Appendix A: BIOS POST Codes ............................................................................ A-1
Appendix B: Software Installation .........................................................................B-1
Appendix C: System Specifications ...................................................................... C-1
Notes
x
SUPERSERVER 6024H-82R/6024H-82/6024H-i2 User's Manual
Chapter 1
Introduction
1-1 Overview
The Supermicro SuperServer 6024H-82R/6024H-82/6024H-i2 is a high-end dual processor server that is comprised of two main subsystems: the SC823S-R500RC/SC823S-550LP/SC823i-550LP 2U server chassis and the X6DH8-G2/X6DHE-G2 Intel Xeon dual processor serverboard. Please refer to our web site for information on operating systems that have been certi­fied for use with the SuperServer 6024H-82R/6024H-82/6024H-i2.
In addition to the serverboard and chassis, various hardware components have been included with the 6024H-82R/6024H-82/6024H-i2:
z One (1) 3.5" floppy drive [FPD-PNSC-02(1)]
z One (1) slim CD-ROM drive [CDM-TEAC-24(B)]
z Four (4) 8-cm hot-swap chassis fans (FAN-0070)
z One (1) 2U chassis air shroud (CSE-PT47)
z One (1) 5.25" dummy drive tray [CSE-PT41(B)]
z One (1) 2U active PCI riser card (CSE-RR2UE-AX, 6024H-82R only)
z One (1) front control panel cable (CBL-0049)
z One (1) rackmount kit (CSE-PT025)
z SCSI Accessories (6024H-82R/6024H-82 only)
One (1) SCSI backplane [CSE-SCA-822S]
One (1) 9" two-drop SCSI cable (CBL-0033-U320)
Six (6) SCA 1-inch high SCSI drive carriers [CSE-PT17(B)]
z IDE Accessories (6024H-i2 only)
Two (2) IDE drive carriers [CSE-PT18(B)]
One (1) IDE cable (CBL-0036)
z Optional: One (1) front access USB kit [CSE-PT29(B)]
Chapter 1: Introduction
1-1
1-2
SUPERSERVER 6024H-82R/6024H-82/6024H-i2 User's Manual
1-2 Serverboard Features
At the heart of the SuperServer 6024H-82R/6024H-82/6024H-i2 lies the X6DH8-G2/X6DHE-G2, a dual processor serverboard based on the Intel E7520 chipset. Below are the main features of the X6DH8-G2/X6DHE-G2. (See Figure 1-1 for a block diagram of the E7520 chipset).
Processors
The X6DH8-G2/X6DHE-G2 supports single or dual 604-pin Intel Xeon EM64T type processors at a FSB speed of 800 MHz. Please refer to the serverboard description pages on our web site for a complete listing of supported processors (www.supermicro.com).
Memory
The X6DH8-G2/X6DHE-G2 has eight 240-pin DIMM slots that can support up to 16 GB of registered ECC DDR2-400 SDRAM. The memory is an inter­leaved configuration, which requires modules of the same size and speed to be installed in pairs.
Onboard SCSI (6024H-82R/6024H-82 only)
Onboard SCSI is provided with an Adaptec AIC-7902 SCSI chip, which sup­ports dual channel, Ultra320 SCSI at a throughput of 320 MB/sec for each channel. The X6DH8-G2 provides two LVD Ultra320 SCSI ports.
Onboard Controllers/Ports
One floppy drive controller and two onboard ATA/100 controllers are pro­vided to support up to four hard drives or ATAPI devices. The color-coded I/O ports include one COM port (an additional COM header is located on the serverboard), a VGA (monitor) port, a parallel port, two USB 2.0 ports, PS/ 2 mouse and keyboard ports and two G-bit Ethernet ports.
1-3
Chapter 1: Introduction
ATI Graphics Controller
The X6DH8-G2/X6DHE-G2 features an integrated ATI video controller based on the Rage XL graphics chip. Rage XL fully supports sideband addressing and AGP texturing. This onboard graphics package can provide a band­width of up to 512 MB/sec over a 32-bit graphics memory bus.
Other Features
Other onboard features that promote system health include onboard voltage monitors, a chassis intrusion header, auto-switching voltage regulators, chassis and CPU overheat sensors, virus protection and BIOS rescue.
1-3 Server Chassis Features
The SuperServer 6024H-82R/6024H-82/6024H-i2 is a high-end, scaleable server platform. The following is a general outline of the main features of the SC823S-R500RC/SC823S-550LP/SC823i-550LP server chassis.
System Power
6024H-82R: the SC823S-R500RC features a redundant 500W power supply that consists of two separate power supply modules. Under normal opera­tion, both modules share the load and run continuously. If one fails, the other module will pick up the load and keep the system running without interruption. A failed power supply module will illuminate the power fail LED. The power supply modules are hot-swappable, so you don't have to power down the system to replace a module.
6024H-82/6024H-i2: the SC823S-550LP/SC823i-550LP features a single 550W power supply. Power must be removed from the system before servicing or replacing this power supply.
SCSI Subsystem (6024H-82R/6024H-82 only)
The SCSI subsystem supports up to six 80-pin SCA Ultra320 SCSI hard drives. Any standard 1" drives are supported. SCA = Single Connection Attachment.) The SCSI drives are connected to an SCA backplane with SAF-TE. The SCSI drives are also hot-swap units. A RAID controller card can be used with the SCA backplane to provide data security. Note: The operating system you use must have RAID support to enable the hot-swap capability of the SCSI drives.
1-4
SUPERSERVER 6024H-82R/6024H-82/6024H-i2 User's Manual
PCI Expansion Slots
Included with the 6024H-82R is the CSE-RR2UE-AX riser card, which sup­ports the use of one standard size 133 MHz PCI-X and two standard size 100 MHz PCI-X cards. The CSE-RR2UE-AX riser card plugs into an x8 PCI­Express slot on the serverboard.
The 6024H-82/6024H-i2 does not include a riser card but instead supports the use of low profile, full-length cards, which are plugged directly into their respective slots on the serverboard: two x8 PCI-Express, one x4 PCI-Ex­press, one 64-bit 133 MHz PCI-X and two 64-bit 100 MHz PCI-X (one 100 MHz PCI slot supports Zero Channel RAID).
Front Control Panel
The SuperServer 6024H-82R/6024H-82/6024H-i2's control panel provides you with system monitoring and control. LEDs indicate system power, HDD activity, network activity, system overheat and power supply failure (this last LED is for the 6024H-82R only). A main power button and a system reset button are also included.
I/O Backplane
The SC823S-R500RC/SC823S-550LP/SC823i-550LP is an ATX form factor chassis that is designed to be used in a 2U rackmount configuration. Ports on the I/O backplane include one COM port, a parallel port, a VGA port, two USB 2.0 ports, PS/2 mouse and keyboard ports and two gigabit Ethernet ports.
Cooling System
The SC823S-R500RC/SC823S-550LP/SC823i-550LP chassis has an innova­tive cooling design that includes four 8-cm hot-plug system cooling fans located in the middle section of the chassis. An air shroud channels the air flow from these fans to efficiently cool the processor area of the system. The power supply module(s) also includes a cooling fan. There is an "Auto Fan Control" setting in BIOS that allows chassis fan speed to be controlled by varying the DC voltage.
1-5
Chapter 1: Introduction
Figure 1-1. Intel E7520 Chipset:
System Block Diagram
Note: This is a general block diagram. Please see Chapter 5 for details.
MCH
MCH
NOCONA CPU 2
NOCONA CPU 2
NOCONA CPU 1
NOCONA CPU 1
ICH5
ICH5
HUB
HUB
DDRII-400
DDRII-400
PCI (32-BIT)
PCI (32-BIT)
A
PXH
PXH
B
PCI E. A (X8)
PCI E. A (X8)
1 PCI-X
1 PCI-X
SLOT
SLOT
ZCR
ZCR
SCSI
SCSI
SLOT
SLOT
7902
7902
1 PCI-X
1 PCI-X
PCI-X(133MHz)
PCI-X(133MHz)
Gbit LAN
Gbit LAN
SLOT
SLOT
1 PCI-X
1 PCI-X
J13
J13
PCI-X(100MHz)
PCI-X(100MHz)
J14
J14
J12
J12
ANVIK
ANVIK
1 PCI-EXP
1 PCI-EXP
SLOT
SLOT
J17
J17
PCI-E B (X8
PCI-E B (X8
)
)
PCI-E C (X8 )
PCI-E C (X8 )
J15
J15
1 PCI-E
1 PCI-E
SLOT
SLOT
1 PCI-E
1 PCI-E
J16
J16
SLOT
SLOT
4 DIMMs
4 DIMMs
IDE
IDE
PRI/SEC
PRI/SEC
UDMA/100
UDMA/100
VGA
VGA
X4
X4
X4
X4
4 DIMMs
4 DIMMs
0, 1
0, 1
SATA
SATA
SATA
SATA
LPC BUS
LPC BUS
USB
USB
USB PORT
USB PORT
0,1,2,3,4,5
0,1,2,3,4,5
BMC CON.
BMC CON.
LPCS I/O
LPCS I/O
FWH
FWH
LPCS I/O
LPCS I/O
MS.
MS.
FDD.
FDD.
H/W
H/W
SER.1
SER.1
SER.2
SER.2
KB.
KB.
MONITOR
MONITOR
4 DDR II -
4 DDR II -
4 DDR II -
4 DDR II -
DDRII-400
DDRII-400
PARALL.
PARALL.
PORT
1-6
SUPERSERVER 6024H-82R/6024H-82/6024H-i2 User's Manual
1-4 Contacting Supermicro
Headquarters
Address: SuperMicro Computer, Inc.
980 Rock Ave.
San Jose, CA 95131 U.S.A. Tel: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: marketing@supermicro.com (General Information)
support@supermicro.com (Technical Support) Web Site: www.supermicro.com
Europe
Address: SuperMicro Computer B.V.
Het Sterrenbeeld 28, 5215 ML
's-Hertogenbosch, The Netherlands Tel: +31 (0) 73-6400390 Fax: +31 (0) 73-6416525 Email: sales@supermicro.nl (General Information)
support@supermicro.nl (Technical Support)
rma@supermicro.nl (Customer Support)
Asia-Pacific
Address: SuperMicro, Taiwan
4F, No. 232-1, Liancheng Rd.
Chung-Ho 235, Taipei County
Taiwan, R.O.C. Tel: +886-(2) 8226-3990 Fax: +886-(2) 8226-3991 Web Site: www.supermicro.com.tw Technical Support: Email: support@supermicro.com.tw Tel: 886-2-8228-1366, ext.132 or 139
Chapter 2: Server Installation
2-1
Chapter 2
Server Installation
2-1 Overview
This chapter provides a quick setup checklist to get your SuperServer 6024H-82R/6024H-82/6024H-i2 up and running. Following these steps in the order given should enable you to have the system operational within a minimum amount of time. This quick setup assumes that your system has come to you with the processors and memory preinstalled. If your system is not already fully integrated with a serverboard, processors, system memory etc., please turn to the chapter or section noted in each step for details on installing specific components.
2-2 Unpacking the System
You should inspect the box the SuperServer 6024H-82R/6024H-82/6024H-i2 was shipped in and note if it was damaged in any way. If the server itself shows damage you should file a damage claim with the carrier who deliv­ered it.
Decide on a suitable location for the rack unit that will hold the SuperServer 6024H-82R/6024H-82/6024H-i2. It should be situated in a clean, dust-free area that is well ventilated. Avoid areas where heat, electrical noise and electromagnetic fields are generated. You will also need it placed near a grounded power outlet. Read the Rack and Server Precautions in the next section.
2-3 Preparing for Setup
The box the SuperServer 6024H-82R/6024H-82/6024H-i2 was shipped in should include two sets of rail assemblies, two rail mounting brackets and the mounting screws you will need to install the system into the rack. Fol­low the steps in the order given to complete the installation process in a minimum amount of time. Please read this section in its entirety before you begin the installation procedure outlined in the sections that follow.
2-2
SUPERSERVER 6024H-82R/6024H-82/6024H-i2 User's Manual
Choosing a Setup Location
- Leave enough clearance in front of the rack to enable you to open
the front door completely (~25 inches).
- Leave approximately 30 inches of clearance in the back of the rack
to allow for sufficient airflow and ease in servicing.
-This product is for installation only in a Restricted Access Location (dedi­cated equipment rooms, service closets and the like).
Rack Precautions
- Ensure that the leveling jacks on the bottom of the rack are fully
extended to the floor with the full weight of the rack resting on them.
- In single rack installation, stabilizers should be attached to the rack.
- In multiple rack installations, the racks should be coupled together.
- Always make sure the rack is stable before extending a component
from the rack.
- You should extend only one component at a time - extending two or
more simultaneously may cause the rack to become unstable.
Server Precautions
- Review the electrical and general safety precautions in Chapter 4.
- Determine the placement of each component in the rack before you
install the rails.
- Install the heaviest server components on the bottom of the rack
first, and then work up.
- Use a regulating uninterruptible power supply (UPS) to protect the server from power surges, voltage spikes and to keep your system operating in case of a power failure.
- Allow the hot plug SCSI drives and power supply units to cool before
touching them.
- Always keep the rack's front door and all panels and components on
the servers closed when not servicing to maintain proper cooling.
!
!
Warnings and Precautions!
Chapter 2: Server Installation
2-3
Rack Mounting Considerations
Ambient Operating Temperature
If installed in a closed or multi-unit rack assembly, the ambient operating temperature of the rack environment may be greater than the ambient temperature of the room. Therefore, consideration should be given to installing the equipment in an environment compatible with the manufacturer’s maximum rated ambient temperature (Tmra).
Reduced Airflow
Equipment should be mounted into a rack so that the amount of airflow required for safe operation is not compromised.
Mechanical Loading
Equipment should be mounted into a rack so that a hazardous condition does not arise due to uneven mechanical loading.
Circuit Overloading
Consideration should be given to the connection of the equipment to the power supply circuitry and the effect that any possible overloading of circuits might have on overcurrent protection and power supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.
Reliable Ground
A reliable ground must be maintained at all times. To ensure this, the rack itself should be grounded. Particular attention should be given to power supply con­nections other than the direct connections to the branch circuit (i.e. the use of power strips, etc.).
2-4
SUPERSERVER 6024H-82R/6024H-82/6024H-i2 User's Manual
2-4 Installing the System into a Rack
This section provides information on installing the SuperServer 6024H-82R/ 6024H-82/6024H-i2 into a rack unit. If the 6024H-82R/6024H-82/6024H-i2 has already been mounted into a rack, you can skip ahead to Sections 2-5 and 2-6. There are a variety of rack units on the market, which may mean the assembly procedure will differ slightly. The following is a guideline for installing the 6024H-82R/6024H-82/6024H-i2 into a rack with the rack rails provided. You should also refer to the installation instructions that came with the rack unit you are using.
Identifying the Sections of the Rack Rails
You should have received two rack rail assemblies with the SuperServer 6024H-82R/6024H-82/6024H-i2. Each of these assemblies consist of two sections: an inner fixed chassis rail that secures to the 6024H-82R/6024H­82/6024H-i2 (A) and an outer fixed rack rail that secures directly to the rack itself (B). All screws and hardware mentioned in the installation steps should be included in the hardware kit. To remove the fixed chassis rail (A), pull it out as far as possible - you should hear a "click" sound as a locking tab emerges from inside the rail assembly and locks the inner rail. Then depress the locking tab to pull the inner rail completely out. Do this for both the left and right side rack rail assemblies.
Figure 2-1. Identifying the Sections of the Rack Rails
A
B
Locking Tab
Chapter 2: Server Installation
2-5
Installing the Chassis Rails
Position the fixed chassis rail sections you just removed along the side of the 6024H-82R/6024H-82/6024H-i2 making sure the screw holes line up. Note that these two rails are left/right specific. Screw the rail securely to the side of the chassis (see Figure 2-2). Repeat this procedure for the other rail on the other side of the chassis. You will also need to attach the rail brackets when installng into a telco rack.
Locking Tabs: As mentioned, both chassis rails have a locking tab, which serves two functions. The first is to lock the server into place when installed and pushed fully into the rack, which is its normal position. Sec­ondly, these tabs also lock the server in place when fully extended from the rack. This prevents the server from coming completely out of the rack when you pull it out for servicing.
Figure 2-2. Installing Chassis Rails
2-6
SUPERSERVER 6024H-82R/6024H-82/6024H-i2 User's Manual
Figure 2-3. Assembling the Rack Rails
Installing the Rack Rails:
Determine where you want to place the SuperServer 6024H-82R/6024H-82/ 6024H-i2 in the rack. (See Rack and Server Precautions in Section 2-3.) Position the fixed rack rail/sliding rail guide assemblies at the desired loca­tion in the rack, keeping the sliding rail guide facing the inside of the rack. Screw the assembly securely to the rack using the brackets provided. Attach the other assembly to the other side of the rack, making sure both are at the exact same height and with the rail guides facing inward (see Figure 2-3).
Installing the Server into the Rack
You should now have rails attached to both the chassis and the rack unit. The next step is to install the server into the rack. Do this by lining up the rear of the chassis rails with the front of the rack rails. Slide the chassis rails into the rack rails, keeping the pressure even on both sides (you may have to depress the locking tabs when inserting). See Figure 2-4.
When the server has been pushed completely into the rack, you should hear the locking tabs "click". Finish by inserting and tightening the thumbscrews that hold the front of the server to the rack.
Chapter 2: Server Installation
2-7
Installing the Server into a Telco Rack
If you are installing the SuperServer 6024H-82R/6024H-82/6024H-i2 into a Telco type rack, follow the directions given on the previous pages for rack installation. The only difference in the installation procedure will be the positioning of the rack brackets to the rack. They should be spaced apart just enough to accommodate the width of the telco rack.
Figure 2-4. Installing the Server into a Rack
2-8
SUPERSERVER 6024H-82R/6024H-82/6024H-i2 User's Manual
2-5 Checking the Serverboard Setup
After you install the 6024H-82R/6024H-82/6024H-i2 in the rack, you will need to open the unit to make sure the serverboard is properly installed and all the connections have been made.
1. Accessing the inside of the system (see Figure 2-5)
First, release the retention screws that secure the unit to the rack. Grasp the two handles on either side and pull the unit straight out until it locks (you will hear a "click"). Next, depress the two buttons on the top of the chassis to release the top cover. You can then lift the top cover from the chassis to gain full access to the inside of the server.
2. Check the CPUs (processors)
You may have one or two processors already installed into the serverboard. Each processor needs its own heatsink. See Chapter 5 for instructions on processor and heatsink installation.
3. Check the system memory
Your 6024H-82R/6024H-82/6024H-i2 server system may have come with system memory already installed. Make sure all DIMMs are fully seated in their slots. For details on adding system memory, refer to Chapter 5.
4. Installing add-on cards
If desired, you can install add-on cards to the system. See Chapter 5 for details on installing PCI add-on cards.
5. Check all cable connections and airflow
Make sure all power and data cables are properly connected and not blocking the chassis airflow. Also make sure that no cables are posi­tioned in front of the fans. See Chapter 5 for details on cable connec­tions.
Chapter 2: Server Installation
2-9
Figure 2-5. Accessing the Inside of the System
2-10
SUPERSERVER 6024H-82R/6024H-82/6024H-i2 User's Manual
2-6 Checking the Drive Bay Setup
Next, you should check to make sure the peripheral drives and the SCSI drives and SCA backplane have been properly installed and all connections have been made.
1. Accessing the drive bays
All drives are accessable from the front of the server. For servicing the CD-ROM and floppy drives, you will need to remove the top chassis cover. The SCSI disk drives can be installed and removed from the front of the chassis without removing the top chassis cover.
2. CD-ROM and floppy disk drives
A slim CD-ROM and a floppy drive should be preinstalled in your server. Refer to Chapter 6 if you need to reinstall a CD-ROM and/or floppy disk drive to the system.
3. Check the SCSI disk drives (6024H-82R/6024H-82 only)
Depending upon your system's configuration, your system may have one or more drives already installed. If you need to install SCSI drives, please refer to Chapter 6.
4. Check the airflow
Airflow is provided by four 8-cm center chassis cooling fans. An air shroud is also included in the system to maximize airflow. The system component layout was carefully designed to direct sufficient cooling air­flow to the components that generate the most heat. Note that all power and data cables have been routed in such a way that they do not block the airflow generated by the fans.
5. Supplying power to the system
The last thing you must do is to provide input power to the system. Plug the power cords from the power supply units into a high-quality power strip that offers protection from electrical noise and power surges. It is rec­ommended that you use an uninterruptible power supply (UPS).
Chapter 3: System Interface
3-1
Chapter 3
System Interface
3-1 Overview
There are several LEDs on the control panel as well as others on the SCSI drive carriers (6024H-82R/6024H-82 only) to keep you constantly informed of the overall status of the system as well as the activity and health of specific components. There are also two buttons on the chassis control panel.
3-2 Control Panel Buttons
The two push-buttons located on the front of the chassis are (in order from left to right) a reset button and a power on/off button.
z RESET: Use the reset button to reboot the system.
z POWER: This is the main power button, which is used to apply or turn
off the main system power. Turning off system power with this button removes the main power but keeps standby power supplied to the system.
SUPERSERVER 6024H-82R/6024H-82/6024H-i2 User's Manual
3-2
3-3 Control Panel LEDs
The control panel located on the front of the chassis has several LEDs. These LEDs provide you with critical information related to different parts of the system. From right to left, they are power, HDD, NIC2, NIC1, Overheat/ Fan Fail and Power Fail. This section explains what each LED indicates when illuminated and any corrective action you may need to take.
z Power Fail: Indicates a power supply module has failed. The sec- ond power supply module will take the load and keep the system running but the failed module will need to be replaced. Refer to Chapter 6 for details on replacing the power supply. This LED should be off when the system is operating normally. Note: the Power Fail LED applies only to the 6024H-82R. It is not needed for the 6024H-82/6024H-i2, which has only a single power supply.
z Overheat/Fan Fail: When this LED flashes, it indicates a fan failure. When on continuously it indicates an overheat condition, which may be caused by cables obstructing the airflow in the system or the ambient room temperature being too warm. Check the routing of the cables and make sure all fans are present and operating normally. You should also check to make sure that the chassis covers are installed. Finally, verify that the heatsinks are installed properly (see Chapter 5). This LED will remain flash­ing or on as long as the indicated condition exists.
z NIC2: Indicates network activity on LAN2 when flashing.
Chapter 3: System Interface
3-3
z NIC1: Indicates network activity on LAN1 when flashing.
z HDD: Indicates IDE channel activity. On the SuperServer 6024H-82R/
6024H-82/6024H-i2, this LED indicates SCSI/CD-ROM and IDE drive activity when flashing.
z Power: Indicates power is being supplied to the system's power
supply units. This LED should normally be illuminated when the system is operating.
3-4 SCSI Drive Carrier LEDs (6024H-82R/6024H-82
only)
A SCSI drive carrier has two LEDs.
z Green: When illuminated, the green LED on the front of the SCSI drive
carrier indicates drive activity. A connection to the SCSI SCA backplane enables this LED to blink on and off when that particular drive is being accessed.
z Red: A SAF-TE compliant backplane is needed to activate the red LED, which indicates a drive failure. (A SAF-TE compliant SCSI backplane is standard on the 6024H-82R/6024H-82.) If one of the SCSI drives fail, you should be notified by your system management software. Please refer to Chapter 6 for instructions on replacing failed SCSI drives.
SUPERSERVER 6024H-82R/6024H-82/6024H-i2 User's Manual
3-4
Notes
Loading...
+ 92 hidden pages