Supero SUPERSERVER 6017R-WRF, SUPERSERVER 6017R-NTF User Manual

SUPER
®
USER'S MANUAL
Revision 1.0a
SUPERSERVER
6017R-WRF
6017R-NTF
The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccuracies that may be contained in this document, makes no commitment to update or to keep current the information in this manual, or to notify any person or organization of the updates. Please Note: For the most up-to-date version of this
manual, please see our web site at
www.supermicro.com.
Super Micro Computer, Inc. ("Supermicro") reserves the right to make changes to the product described in this manual at any time and without notice. This product, including software and documentation, is the property of Supermicro and/or its licensors, and is supplied only under a license. Any use or reproduction of this product is not allowed, except as expressly permitted by the terms of said license.
IN NO EVENT WILL SUPERMICRO BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL, SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO USE THIS PRODUCT OR DOCUMENTATION, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. IN PARTICULAR, SUPERMICRO SHALL NOT HAVE LIABILITY FOR ANY HARDWARE, SOFTW ARE, OR DA TA ST ORED OR USED WITH THE PRODUCT, INCLUDING THE COSTS OF REPAIRING, REPLACING, INTEGRATING, INSTALLING OR RECOVERING SUCH HARDWARE, SOFTWARE, OR DATA.
Any disputes arising between manufacturer and customer shall be governed by the laws of Santa Clara County in the State of California, USA. The State of California, County of Santa Clara shall be the exclusive venue for the resolution of any such disputes. Super Micro's total liability for all claims will not exceed the price paid for the hardware product.
FCC Statement: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the manufacturer’s instruction manual, may cause harmful interference with radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case you will be required to correct the interference at your own expense.
California Best Management Practices Regulations for Perchlorate Materials: This Perchlorate warning applies only to products containing CR (Manganese Dioxide) Lithium coin cells. “Perchlorate Material-special handling may apply. See
www.dtsc.ca.gov/hazardouswaste/perchlorate
WARNING: Handling of lead solder materials used in this product may expose you to lead, a chemical known to the State of California to cause birth defects and other reproductive harm.
Manual Revision 1.0b Release Date: June 06, 2014
Unless you request and receive written permission from Super Micro Computer, Inc., you may not copy any part of this document.
Information in this document is subject to change without notice. Other products and companies referred to herein are trademarks or registered trademarks of their respective companies or mark holders.
Copyright © 2014 by Super Micro Computer, Inc. All rights reserved.
Printed in the United States of America
Preface
About This Manual
This manual is written for professional system integrators and PC technicians. It provides information for the installation and use of the SuperServer 6017R-WRF/NTF . Installation and maintenance should be performed by experienced technicians only .
The SuperServer 6017R-WRF/NTF is a 1U rackmount server based on the SC815TQ-R700WB/600WB server chassis and the X9DRW-iF serverboard. Please refer to our web site for updates on supported processors.
The only difference between the 6017R-WRF and 6017R-NTF servers is that the 6017R-WRF uses the R700WB 700 Watt power suppply, and the 6017R-NTF uses the 600WB 600 Watt power supply.
Manual Organization
Chapter 1: Introduction
The fi rst chapter provides a checklist of the main components included with the server system and describes the main features of the X9DRW-iF serverboard and the SC815TQ-R700WB/600WB chassis.
Chapter 2: Server Installation
This chapter describes the steps necessary to install the SuperServer 6017R-WRF/NTF into a rack and check out the server confi guration prior to powering up the system. If your server was ordered without the processor and memory components, this chapter will refer you to the appropriate sections of the manual for their installation.
Chapter 3: System Interface
Refer to this chapter for details on the system interface, which includes the functions and information provided by the control panel on the chassis as well as other LEDs located throughout the system.
Chapter 4: Standardized Warning Statements for AC Systems
You should thoroughly familiarize yourself with this chapter for a general overview of safety precautions that should be followed when installing and servicing the SuperServer 6017R-WRF/NTF.
iii
Preface
SUPERSERVER 6017R-WRF/NTF USER'S MANUAL
iv
Chapter 5: Advanced Serverboard Setup
This chapter provides detailed information on the X9DRW-iF serverboard, including the locations and functions of connectors, headers and jumpers. Refer to this chapter when adding or removing processors or main memory and when reconfi guring the serverboard.
Chapter 6: Advanced Chassis Setup
Refer to Chapter 6 for detailed information on the SC815TQ-R700WB/600WB chassis. You should follow the procedures given in this chapter when installing, removing or reconfi guring Serial A T A or peripheral drives and when replacing system power supply units and cooling fans.
Chapter 7: BIOS
The BIOS chapter includes an introduction to BIOS and provides detailed information on running the CMOS Setup Utility.
Appendix A: BIOS POST Error Codes Appendix B: Installing Windows Appendix C: System Specifi cations
v
Preface
Notes
vi
SUPERSERVER 6017R-WRF/NTF USER'S MANUAL
Table of Contents
Chapter 1 Introduction
1-1 Overview .........................................................................................................1-1
1-2 Serverboard Features .....................................................................................1-2
Processors ......................................................................................................1-2
Memory ...........................................................................................................1-2
Serial ATA ....................................................................................................... 1-2
Onboard Controllers/Ports .............................................................................. 1-3
Graphics Controller .........................................................................................1-3
Other Features ................................................................................................ 1-3
1-3 Server Chassis Features ................................................................................ 1-3
System Power ................................................................................................. 1-3
Hard Drive Subsystem .................................................................................... 1-3
PCI Expansion Slots .......................................................................................1-4
Front Control Panel ......................................................................................... 1-4
I/O Backplane ..................................................................................................1-4
Cooling System ............................................................................................... 1-4
1-4 Advanced Power Management ....................................................................... 1-5
Intel® Intelligent Power Node Manager (NM) .................................................1-5
Manageability Engine (ME) ............................................................................. 1-5
1-5 Contacting Supermicro ....................................................................................1-7
Chapter 2 Server Installation
2-1 Overview .........................................................................................................2-1
2-2 Unpacking the System .................................................................................... 2-1
2-3 Preparing for Setup ......................................................................................... 2-1
Choosing a Setup Location .............................................................................2-2
2-4 Warnings and Precautions .............................................................................. 2-2
Rack Precautions ............................................................................................ 2-2
Server Precautions ..........................................................................................2-2
Rack Mounting Considerations ....................................................................... 2-3
Ambient Operating Temperature ................................................................ 2-3
Reduced Airfl ow ......................................................................................... 2-3
Mechanical Loading ................................................................................... 2-3
Circuit Overloading ..................................................................................... 2-4
Reliable Ground ......................................................................................... 2-4
2-5 Installing the System into a Rack ...................................................................2-5
Identifying the Sections of the Rack Rails ...................................................... 2-5
vii
Table of Contents
Installing the Inner Rails ................................................................................. 2-5
Installing the Outer Rails .................................................................................2-6
Installing the Server into the Rack ..................................................................2-7
2-6 Checking the Serverboard Setup ....................................................................2-8
2-7 Checking the Drive Bay Setup ........................................................................2-9
Chapter 3 System Interface
3-1 Overview .........................................................................................................3-1
3-2 Control Panel Buttons ..................................................................................... 3-2
Reset ...............................................................................................................3-2
Power ..............................................................................................................3-2
UID ..................................................................................................................3-2
3-3 Control Panel LEDs ........................................................................................ 3-3
Information LED ..............................................................................................3-3
NIC2 ................................................................................................................3-3
NIC1 ................................................................................................................3-3
HDD ................................................................................................................. 3-3
Power ..............................................................................................................3-4
3-4 Hard Drive Carrier LEDs ................................................................................. 3-4
Chapter 4 Standardized Warning Statements for AC Systems
4-1 About Standardized Warning Statements ....................................................... 4-1
Warning Defi nition ...........................................................................................4-1
Installation Instructions ....................................................................................4-4
Circuit Breaker ................................................................................................ 4-5
Power Disconnection Warning ........................................................................ 4-6
Equipment Installation ..................................................................................... 4-8
Restricted Area ................................................................................................ 4-9
Battery Handling ............................................................................................4-10
Redundant Power Supplies .......................................................................... 4-12
Backplane Voltage ........................................................................................4-13
Comply with Local and National Electrical Codes ........................................ 4-14
Product Disposal ........................................................................................... 4-15
Easy Swap Fan Warning ..............................................................................4-16
Power Cable and AC Adapter ......................................................................4-18
viii
SUPERSERVER 6017R-WRF/NTF USER'S MANUAL
Chapter 5 Advanced Serverboard Setup
5-1 Handling the Serverboard ............................................................................... 5-1
Precautions .....................................................................................................5-1
Unpacking .......................................................................................................5-1
5-2 Processor and Heatsink Installation................................................................5-2
Installing a Passive CPU Heatsink .................................................................5-6
Removing the Heatsink ................................................................................... 5-7
5-3 Connecting Cables .......................................................................................... 5-7
Connecting Data Cables ................................................................................. 5-7
Connecting Power Cables .............................................................................. 5-8
Connecting the Control Panel ......................................................................... 5-8
5-4 I/O Ports ..........................................................................................................5-9
5-5 Installing Memory .......................................................................................... 5-10
Memory Support ............................................................................................5-10
5-6 Adding PCI Expansion Cards .......................................................................5-12
PCI Expansion Slots ................................................................................ 5-12
5-7 Serverboard Details ...................................................................................... 5-13
X9DRW-iF Quick Reference ......................................................................... 5-14
5-8 Connector Defi nitions ................................................................................... 5-16
Power Connectors ...................................................................................5-16
PW_ON Connector ...................................................................................5-17
Reset Connector ...................................................................................... 5-17
Power Fail LED ........................................................................................5-17
Overheat/Fan Fail LED (OH)....................................................................5-17
NIC1 (LAN1) LED .....................................................................................5-18
HDD LED ..................................................................................................5-18
Power On LED .........................................................................................5-18
NMI Button ............................................................................................... 5-18
Chassis Intrusion ...................................................................................... 5-18
Universal Serial Bus (USB) ...................................................................... 5-19
Ethernet Ports .......................................................................................... 5-19
Video Connection ..................................................................................... 5-19
Serial Ports ............................................................................................... 5-20
Fan Headers .............................................................................................5-20
Power LED/Speaker ................................................................................. 5-20
Unit Identifi er Switch ................................................................................5-21
Internal Speaker ....................................................................................... 5-21
Overheat LED/Fan Fail ............................................................................ 5-22
Table of Contents
ix
Power SMB (I2C) Connector ....................................................................5-22
Port 80 Header ......................................................................................... 5-22
IPMB .........................................................................................................5-23
T-SGPIO 1/2 Headers .............................................................................. 5-23
DOM Power Connector ............................................................................ 5-23
Standby Power Connector .......................................................................5-23
Legacy Wake-On-LAN Header (JSTBY) .................................................. 5-24
5-9 Jumper Settings ............................................................................................5-25
Explanation of Jumpers ................................................................................ 5-25
CMOS Clear ............................................................................................. 5-25
LAN Enable/Disable .................................................................................5-26
Watch Dog Enable/Disable ......................................................................5-26
VGA Enable/Disable .................................................................................5-26
BMC Enable ............................................................................................ 5-26
I2C Bus to PCI-Exp. Slots ........................................................................5-26
5-10 Onboard Indicators ........................................................................................5-27
GLAN LEDs .............................................................................................. 5-27
IPMI Dedicated LAN LEDs .......................................................................5-27
Onboard Power LED ................................................................................ 5-27
Rear UID LED ......................................................................................... 5-28
BMC Heartbeat LED ................................................................................ 5-28
5-11 SATA Drive Connections ............................................................................... 5-28
SATA/SC8U Ports .....................................................................................5-28
5-12 Installing Software ......................................................................................... 5-29
SuperDoctor III .............................................................................................. 5-30
5-13 Serverboard Battery ......................................................................................5-32
Chapter 6 Advanced Chassis Setup
6-1 Static-Sensitive Devices ..................................................................................6-1
Precautions .....................................................................................................6-1
6-2 Control Panel ..................................................................................................6-2
6-3 System Fans ...................................................................................................6-2
System Fan Failure ......................................................................................... 6-3
6-4 Drive Bay Installation/Removal ....................................................................... 6-4
Removing the Front Bezel ..............................................................................6-4
Accessing the Drive Bays ............................................................................... 6-4
Hard Drive Installation ..................................................................................... 6-5
DVD-ROM Drive Installation ...........................................................................6-6
x
SUPERSERVER 6017R-WRF/NTF USER'S MANUAL
6-5 Power Supply .................................................................................................. 6-7
Redundant Power Supply Failure ..............................................................6-7
Chapter 7 BIOS
7-1 Introduction ......................................................................................................7-1
Starting the Setup Utility .................................................................................7-1
7-2 Main Menu ...................................................................................................... 7-1
System Time/System Date .............................................................................7-2
7-3 Advanced Settings Menu ................................................................................ 7-2
7-4 Event Logs .................................................................................................... 7-22
7-5 IPMI ...............................................................................................................7-24
7-6 Boot ...............................................................................................................7-26
7-7 Security .........................................................................................................7-27
7-8 Save & Exit ................................................................................................... 7-27
Appendix A BIOS Error Beep Codes Appendix B System Specifi cations
Chapter 1
Introduction
1-1 Overview
The SuperServer 6017R-WRF/NTF is a high-end server comprised of two main subsystems: the SC815TQ-R700WB/600WB 1U server chassis and the X9DRW-iF dual processor serverboard. Please refer to our web site for information on operating systems that have been certifi ed for use with the system (www.supermicro.com).
In addition to the serverboard and chassis, various hardware components have been included with the SuperServer 6017R-WRF/NTF, as listed below:
Heatsinks:
One (1) 1U Passive CPU Heatsinks (SNK-P0047PSC) One (1) 1U Passive CPU Heatsinks (SNK-P0047PS)
One (1) SC815/113/116 Intel DP X9, X8 PC air shroud (MCP-310-19002-0N)
(6017R-WRF only)
One (1) SC815/113/116 Intel DP X9, X8 PC air shroud (MCP-310-19001-0N)
(6017R-NTF only)
Fans:
Four (4) 40x56mm 4-pin PWM chassis middle fans (FAN-0086L4) One (1) 40x56mm 4-pin PWM chassis middle fan (MCP-340-00022-0N)
One (1) 70-cm round 20-to-20-pin Front Panel Control Cable (CBL-0335L)
SAS/SATA Accessories
One (1) SAS/SATA backplane (BPN-SAS-815TQ-O-P) One (1) 30AWG 76/66/54/45-cm, w/66-cm AOC connection cable (CBL-0343L-01) (6017R-WRF only) One (1) 30AWG 64/54/44/34-cm, w/64-cm SATA connection cable (CBL-0188L-02) (6017R-NTF only) Four (4) hot-swap 3.5" hard-disk drive trays (MCP-220-00075-0B)
One (1) Riser Card (RSC-R1UW-2E16-O-P)
Rail Kit sets:
One (1) set outer rail (screw) for 1U chassis (MCP-290-00101-0N) One (1) set Inner rail, front (screw) for 1U chassis (MCP-290-00105-0N) One (1) set Inner rail, extension (screw) for 1U chassis (MCP-290-00109-0N)
Chapter 1: Introduction
1-1
1-2
SUPERSERVER 6017R-WRF/NTF USER'S MANUAL
Note: For your system to work properly, please follow the links below to download all necessary drivers/utilities and the user’s manual for your server.
Supermicro product manuals: http://www.supermicro.com/support/manuals/
Product drivers and utilities: ftp://ftp.supermicro.com
Product safety information:
http://super-dev/about/policies/safety_information.cfm
If you have any questions, please contact our support team at:
support@supermicor.com
1-2 Serverboard Features
At the heart of the SuperServer 6017R-WRF/NTF lies the X9DRW-iF, a dual processor serverboard based on the Intel PCH 602 chipset. Below are the main features of the X9DRW-iF. (See Figure 1-1 for a block diagram of the chipset).
Processors
The X9DRW-iF supports single or dual E5-2600 Series processors in Socket R LGA2011 type sockets. Please refer to our web site for a complete listing of supported processors (www.supermicro.com).
Memory
The X9DRW-iF has sixteen (16) quad channel 240-pin DIMM sockets that can support up to 512 GB of DDR3 1600/1333/1066/800 MHz speed registered ECC RDIMM/LRDIMM SDRAM in two-channel memory bus. Memory sizes of 1GB, 2GB, 4GB, 8GB, 16GB and 32GB @ 1.35V/1.5V voltages are supported. Please refer to Chapter 5 for installing memory.
Note: LRDIMM (Reduced Load) memory supports only 1333/1066/800 MHz speed memory.
Serial ATA
An on-chip (Intel PCH 602) SATA controller is integrated into the X9D RW-iF to provid e a s i x-port SATA subsys te m (two SATA 3.0 and four SATA 2.0 ports), which is R AID 0, 1, 5 and 10 (W ind ows SATA) or R A ID 0, 1 an d 10 (LINUX ) supp or ted. The SATA dri ves are ho t-swap pable u nits.
Note: You must have RAID set up to enable the hot-swap capability of the SATA drives. D ocum entati on on R AI D setup gui deline s can be fo und on our we b site.
Chapter 1: Introduction
1-3
Onboard Controllers/Ports
The color-coded I/O ports on the X9DRW-iF include two COM ports (one header and one port), a VGA (monitor) port, eight USB 2.0 ports (4x rear, 4x header), two gigabit Ethernet ports and one dedicated IPMI LAN port.
Note 1: For more information on IPMI confi guration, please refer to the IPMI User's Guide posted on our website at
http://www.supermicro.com/support/manuals/ for
more details.
Graphics Controller
The X9DRW-iF features an integrated Renesas Base-board Controller (BMC) chip, which also acts as a video controller.
Other Features
Other onboard features that promote system health include onboard voltage monitors, auto-switching voltage regulators, chassis and CPU overheat sensors, power management, AC power loss recovery, virus protection and BIOS rescue.
1-3 Server Chassis Features
The SuperServer 6017R-WRF/NTF is built upon the SC815TQ-R700WB/600WB chassis. Details on the chassis and on servicing procedures can be found in Chapter
6.The following is a general outline of the main features of both chassis.
System Power
The SC815TQ-R700WB/600WB features either a redundant 700 Watt power supply (6017R-WRF server) or a single 600 Watt power supply (6017R-NTF server). The system does not need to be shut down when replacing or removing a single power supply module.
Hard Drive Subsystem
The SC815TQ-R700WB/600WB cha ssis was design ed to suppor t four hot-swap SAT A hard drives. (The 6017R-WRF requires a PCI-E controller card - not included with system.)
Note: For the 6 017R-WRF, the ha rd drives a re conne cted to fou r onboard S ATA conne ctio ns fro m the SCU C ontro ller.
1-4
SUPERSERVER 6017R-WRF/NTF USER'S MANUAL
PCI Expansion Slots
A riser card (RSC-R1UW-2E16-O-P) on the left side of the chassis can support two PCI-E x16 add-on cards. See our webs site for details (http://www.supermicro.com/
products/info/UIO.cfm). See section 5-6 for further details.
Front Control Panel
The chassis' control panel provides you with system monitoring and control. LEDs indicate system power, HDD activity, network activity (two) and UID/overheat/fan fail/power fail. A main power button, a system reset button and a UID button are also included.
I/O Backplane
The SC815TQ-R700WB/600WB is an extended ATX form factor chassis that is designed to be used in a 1U rackmount confi guration. Ports on the I/O backplane include one COM port, a VGA port, four USB 2.0 ports, two gigabit LAN Ethernet ports and one dedicated IPMI LAN port. A UID (Unit Identifi er) button and LED are also located beside the VGA port.
Cooling System
The SC815TQ-R700WB/600WB chassis has an innovative cooling design that features fi ve sets of 4-cm counter-rotating fans located in the middle section of the chassis. There is a "Fan Speed Control Mode" setting in IPMI that allows chassis fan speed to be determined by system temperature. The power supply module also includes a cooling fan.
Chapter 1: Introduction
1-5
1-4 Advanced Power Management
Intel® Intelligent Power Node Manager (NM)
The Intel® Intelligent Power Node Manager (IPNM) provides your system with real-time thermal control and power management for maximum energy effi ciency. Although IPNM Specifi cation Version 1.5 is supported by the BMC (Baseboard Management Controller), your system must also have IPNM-compatible Manageability Engine (ME) fi rmware installed to use this feature.
Manageability Engine (ME)
The Manageability Engine, which is an ARC controller embedded in the IOH (I/O Hub), provides Server Platform Services (SPS) to your system. The services provided by SPS are different from those proveded by the ME on client platforms.
1-6
SUPERSERVER 6017R-WRF/NTF USER'S MANUAL
Figure 1-1. Intel PCH 602 Chipset:
System Block Diagram
Note: This is a general block diagram. Please see Chapter 5 for details.
PROCESSOR
PROCESSOR
DDR3 DIMM
#1
#2
DDR3 DIMM
DDR3 DIMM
DDR3 DIMM
DDR3 DIMM
#2
#1
DDR3 DIMM
G
A
CPU Rear
DDR3 DIMM
B
DDR3 DIMM
D
C
H
F
E
Socket 00
Socket 01
#1
#2
#1
#2
#1
#2
#1
#2
#1
#2
#1
#2
P0
P0
P1
P1
x1
x16
x16
x16
J1
Right Slot
PCIE 3.0x16
DMI
PE3 PE2 PE1
QPI
QPI
CPU Front
DMI
PE1PE2PE3
P0PE3
J3
Left Slot
PCIE 3.0x16+x16
x4 (Lane4~7)
UL1
I350AM2
JLAN1
RJ45
JLAN2
RJ45
Lane Reversal & Polarity Inversion
DMI: Lane Reversal
BIOS
SPI Flash
SPI
DMI PEG [0...3]
PET8 USB [10,11] LPC
SSB
PCH C602
Gen 3 [1...7]
SATA [0...5]
USB [0...9]
SATA Gen3
SATA Gen2
SATA0
SATA1
SATA2
SATA3
SATA4
SATA5
DDR3 RAM
Renesas
VGA
BMC
TPM Chip
Super I/O
W83527
NCT7904D
HW Monitor
VGA
CONN
PHY
RTL8211E IPMI LAN
RJ45
REAR
HDR 2X5
REAR
3Gbps
6Gbps
JSM2(SCU4~7)
(3F only)
JSM1(SCU0~3)
Chapter 1: Introduction
1-7
1-5 Contacting Supermicro
Headquarters
Address: Super Micro Computer, Inc.
980 Rock Ave.
San Jose, CA 95131 U.S.A. Tel: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: marketing@supermicro.com (General Information)
support@supermicro.com (Technical Support) Web Site:
www.supermicro.com
Europe
Address: Super Micro Computer B.V.
Het Sterrenbeeld 28, 5215 ML
's-Hertogenbosch, The Netherlands Tel: +31 (0) 73-6400390 Fax: +31 (0) 73-6416525 Email: sales@supermicro.nl (General Information)
support@supermicro.nl (Technical Support)
rma@supermicro.nl (Customer Support) Web Site:
www.supermicro.nl
Asia-Pacifi c
Address: Super Micro Computer, Inc.
3F, No. 150, Jian 1st Rd.
Zhonghe Dist., New Taipei City 235
Taiwan (R.O.C) Tel: +886-(2) 8226-3990 Fax: +886-(2) 8226-3992 Email: support@supermicro.com.tw Web Site:
www.supermicro.com.tw
1-8
SUPERSERVER 6017R-WRF/NTF USER'S MANUAL
Notes
Chapter 2: Server Installation
2-1
Chapter 2
Server Installation
2-1 Overview
This chapter provides a quick setup checklist to get your SuperServer 6017R-WRF/NTF up and running. Following these steps in the order given should enable you to have the system operational within a minimum amount of time. This quick setup assumes that your system has come to you with the processors and memory preinstalled. If your system is not already fully integrated with a serverboard, processors, system memory etc., please turn to the chapter or section noted in each step for details on installing specifi c components.
2-2 Unpacking the System
You should inspect the box the SuperServer 6017R-WRF/NTF was shipped in and note if it was damaged in any way. If the server itself shows damage you should le a damage claim with the carrier who delivered it.
Decide on a suitable location for the rack unit that will hold the SuperServer 6017R-WRF/NTF. It should be situated in a clean, dust-free area that is well ventilated. Avoid areas where heat, electrical noise and electromagnetic fi elds are generated. You will also need it placed near a grounded power outlet. Be sure to read the Rack and Server Precautions in the next section.
2-3 Preparing for Setup
The box the SuperServer 6017R-WRF/NTF was shipped in should include two sets of rail assemblies, two rail mounting brackets and the mounting screws you will need to install the system into the rack. Follow the steps in the order given to complete the installation process in a minimum amount of time. Please read this section in its entirety before you begin the installation procedure outlined in the sections that follow.
2-2
SUPERSERVER 6017R-WRF/NTF USER'S MANUAL
Choosing a Setup Location
Leave enough clearance in front of the rack to enable you to open the front door
completely (~25 inches) and approximately 30 inches of clearance in the back of the rack to allow for suffi cient airfl ow and ease in servicing.This product is for installation only in a Restricted Access Location (dedicated equipment rooms, service closets and the like).
This product is not suitable for use with visual display work place devices
acccording to §2 of the the German Ordinance for Work with Visual Display Units.
2-4 Warnings and Precautions
Warning! To prevent bodily injury when mounting or servicing this unit in a
rack, you must take special precautions to ensure that the system remains stable. The following guidelines are provided to ensure your safety:
This unit should be mounted at the bottom of the rack if it is the only unit in
the rack.
When mounting this unit in a partially fi lled rack, load the rack from the bottom
to the top with the heaviest component at the bottom of the rack.
If the rack is provided with stabilizing devices, install the stabilizers before
mounting or servicing the unit in the rack.
Rack Precautions
Ensure that the leveling jacks on the bottom of the rack are fully extended to
the fl oor with the full weight of the rack resting on them.
In single rack installation, stabilizers should be attached to the rack. In multiple
rack installations, the racks should be coupled together.
Always make sure the rack is stable before extending a component from the
rack.
You should extend only one component at a time - extending two or more
simultaneously may cause the rack to become unstable.
Server Precautions
Review the electrical and general safety precautions in Chapter 4.
Determine the placement of each component in the rack before you install the
rails.
Chapter 2: Server Installation
2-3
Install the heaviest server components on the bottom of the rack fi rst, and then
work up.
Use a regulating uninterruptible power supply (UPS) to protect the server from
power surges, voltage spikes and to keep your system operating in case of a power failure.
Allow the hot plug SATA drives and power supply modules to cool before
touching them.
Always keep the rack's front door and all panels and components on the servers
closed when not servicing to maintain proper cooling.
Rack Mounting Considerations
Warning: Do not pick up the server with the front handles. They are
designed to pull the system from a rack only.
Stability Hazard: The rack stabilizing mechanism must be in place, or the rack must be bolted to the fl oor before you slide the unit out for servicing. Failure to stabilize the rack can cause the rack to tip over.
Ambient Operating Temperature
If installed in a closed or multi-unit rack assembly, the ambient operating temperature of the rack environment may be greater than the ambient temperature of the room. Therefore, consideration should be given to installing the equipment in an environment compatible with the manufacturer’s maximum rated ambient temperature (Tmra).
Reduced Airfl ow
Equipment should be mounted into a rack so that the amount of airfl ow required for safe operation is not compromised.
Mechanical Loading
Equipment should be mounted into a rack so that a hazardous condition does not arise due to uneven mechanical loading.
2-4
SUPERSERVER 6017R-WRF/NTF USER'S MANUAL
Circuit Overloading
Consideration should be given to the connection of the equipment to the power supply circuitry and the effect that any possible overloading of circuits might have on overcurrent protection and power supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.
Reliable Ground
A reliable ground must be maintained at all times. To ensure this, the rack itself should be grounded. Particular attention should be given to power supply connections other than the direct connections to the branch circuit (i.e. the use of power strips, etc.).
Chapter 2: Server Installation
2-5
Figure 2-1. Identifying the Sections of the Rack Rails
(right side rail shown)
2-5 Installing the System into a Rack
This section provides information on installing the SuperServer 6017R-WRF/NTF into a rack unit with the rack rails provided. If the system has already been mounted into a rack, you can skip ahead to Sections 2-5 and 2-6.
There are a variety of rack units on the market, which may mean the assembly procedure will differ slightly. You should also refer to the installation instructions that
came with the rack unit you are using.
Identifying the Sections of the Rack Rails
You should have received two rack rail assemblies in the rack mounting kit. Each assembly consists of two sections: an inner fi xed chassis rail that secures directly to the server chassis and an outer fi xed rack rail that secures directly to the rack itself (see Figure 2-1). Two pairs of short brackets to be used on the front side of the outer rails are also included.
Installing the Inner Rails
Both the left and right side inner rails have been pre-attached to the chassis. Proceed to the next step.
2-6
SUPERSERVER 6017R-WRF/NTF USER'S MANUAL
Figure 2-2. Installing the Rack Rails
Installing the Outer Rails
Begin by measuring the distance from the front rail to the rear rail of the rack. Attach a short bracket to the front side of the right outer rail and a long bracket to the rear side of the right outer rail. Adjust both the short and long brackets to the proper distance so that the rail can fi t snugly into the rack. Secure the short bracket to the front side of the outer rail with two screws and the long bracket to the rear side of the outer rail with three screws. Repeat these steps for the left outer rail. See Figure 2-2 for details
Locking Tabs: Both chassis rails have a locking tab, which serves two functions. The fi rst is to lock the server into place when installed and pushed fully into the rack, which is its normal position. Secondly, these tabs also lock the server in place when fully extended from the rack. This prevents the server from coming completely out of the rack when you pull it out for servicing.
Chapter 2: Server Installation
2-7
Figure 2-3. Installing the Server into a Rack
Installing the Server into the Rack
You should now have rails attached to both the chassis and the rack unit. The next step is to install the server into the rack. Do this by lining up the rear of the chassis rails with the front of the rack rails. Slide the chassis rails into the rack rails, keeping the pressure even on both sides (you may have to depress the locking tabs when inserting). See Figure 2-3 for details.
When the server has been pushed completely into the rack, you should hear the locking tabs "click".
Note: The fi gure above is for illustrative purposes only. Always install servers to the bottom of the rack fi rst.
2-8
SUPERSERVER 6017R-WRF/NTF USER'S MANUAL
Figure 2-5. Accessing the Inside of the System
2-6 Checking the Serverboard Setup
After you install the SuperServer 6017R-WRF/NTF in the rack, you will need to open the top cover to make sure the serverboard is properly installed and all the connections have been made.
Accessing the Inside of the System (Figure 2-5)
1. First, grasp the two handles on either side and pull the system straight out until it locks (you will hear a "click").
2. Depress the two buttons on the top of the chassis to release the top cover (1).
3. Push the cover away from you (toward the rear of the chassis) until it stops (2). You can then lift the top cover from the chassis to gain full access to the inside of the server. See Figure 2-5.
4. To remove the system from the rack completely, depress the locking tabs in the chassis rails (push the right-side tab down and the left-side tab up) to continue to pull the system out past the locked position.
Chapter 2: Server Installation
2-9
Checking the Components
1. You may have one or two processors already installed in the serverboard. Each processor needs its own heatsink. See Chapter 5 for instructions on processor and heatsink installation.
2. Your server system may have come with system memory already installed. Make sure all DIMMs are fully seated in their slots. For details on adding system memory, refer to Chapter 5.
3. If desired, you can install add-on cards to the system. See Chapter 5 for details on installing PCI add-on cards.
4. Make sure all power and data cables are properly connected and not blocking the chassis airfl ow. See Chapter 5 for details on cable connections.
2-7 Checking the Drive Bay Setup
Next, you should check to make sure the peripheral drives and the SA TA drives and SA TA backplane have been properly installed and all connections have been made.
Checking the Drives
1. All drives are accessable from the front of the server. The SATA disk drives can be installed and removed from the front of the chassis without removing the top chassis cover.
2. A slim DVD-ROM drive should be preinstalled in your server. For servicing the DVD-ROM drive, you will need to remove the top chassis cover. Refer to Chapter 6 if you need to reinstall a DVD-ROM drive to the system.
3. Depending upon your system's confi guration, your system may have one or more drives already installed. If you need to install SATA drives, please refer to Chapter 6.
Checking the Airfl ow
1. Airfl ow is provided by four sets of 4-cm fans (each set of fans consists of two fans that are mounted back to back). The system component layout was carefully designed to direct suffi cient cooling airfl ow to the components that generate the most heat.
2. Note that all power and data cables have been routed in such a way that they do not block the airfl ow generated by the fans.
Providing Power
1. The last thing you must do is to provide input power to the system. Plug the power cords from the power supply modules into a high-quality power strip that offers protection from electrical noise and power surges.
2. It is recommended that you use an uninterruptible power supply (UPS).
2-10
SUPERSERVER 6017R-WRF/NTF USER'S MANUAL
Notes
Chapter 3: System Interface
3-1
Chapter 3
System Interface
3-1 Overview
There are several LEDs on the control panel as well as others on the SATA drive carriers to keep you constantly informed of the overall status of the system as well as the activity and health of specifi c components. There are also three buttons on the chassis control panel and an on/off switch on the power supply. This chapter explains the meanings of all LED indicators and the appropriate response you may need to take.
Figure 3-1: System Interface
1
8
1
9
7 346 5 12
Server Interface Buttons and LEDs
No. Description
1 Power Button 2 Reset Button 3 Power LED 4 Device Activity LED 5 LAN1 LED and LAN2 LED 6 Information LED 7 Unit Identifi er Button 8 Hard Drive Signal 9 Hard Drive Fail
3-2
SUPERSERVER 6017R-WRF/NTF USER'S MANUAL
UID
Depressing the UID (unit identifi er) button illuminates an LED on both the front and rear of the chassis for easy system location in large stack confi gurations. The LED will remain on until the button is pushed a second time. Another UID button on the rear of the chassis serves the same function. See the table in Figure 3-1 for descriptions of UID LED states.
Universal Information LED States
State Indication
Fast Blinking Red (1x/sec) Fan Fail Solid Red CPU Overheat Slow Blinking Red (1x/4 sec) Power Fail Solid Blue Local UID Button Depressed Blinking Blue IPMI-Activated UID
Note: deactivating the UID LED must be performed in the same way it was activated. (If the UID LED was activated via IPMI, you can only turn the LED off via IPMI and not with the UID button.)
Power
This is the main power button, which is used to apply or turn off the main system power. T urning off system power with this button removes the main power but keeps standby power supplied to the system.
Reset
Use the reset button to reboot the system.
3-2 Control Panel Buttons
There are three push-buttons located on the front of the chassis: a reset button, a UID button and a power on/off button.