SUPER
SUPER SERVER 6015W-Ni
®
USER’S MANUAL
1.0
The information in this User’s Manual has been carefully reviewed and is believed to be accurate.
The vendor assumes no responsibility for any inaccuracies that may be contained in this document,
makes no commitment to update or to keep current the information in this manual, or to notify any
person or organization of the updates. Please Note: For the most up-to-date version of this
manual, please see our web site at www.supermicro.com.
SUPER MICRO COMPUTER reserves the right to make changes to the product described in this
manual at any time and without notice. This product, including software, if any, and documentation may not, in whole or in part, be copied, photocopied, reproduced, translated or reduced to any
medium or machine without prior written consent.
IN NO EVENT WILL SUPER MICRO COMPUTER BE LIABLE FOR DIRECT, INDIRECT, SPECIAL,
INCIDENTAL, SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE
OR INABILITY TO USE THIS PRODUCT OR DOCUMENTATION, EVEN IF ADVISED OF THE
POSSIBILITY OF SUCH DAMAGES. IN PARTICULAR, SUPER MICRO SHALL NOT HAVE
LIABILITY FOR ANY HARDWARE, SOFTWARE, OR DATA STORED OR USED WITH THE
PRODUCT, INCLUDING THE COSTS OF REPAIRING, REPLACING, INTEGRATING, INSTALLING
OR RECOVERING SUCH HARDWARE, SOFTWARE, OR DATA.
Any disputes arising between manufacturer and customer shall be governed by the laws of Santa
Clara County in the State of California, USA. The State of California, County of Santa Clara shall
be the exclusive venue for the resolution of any such disputes. Super Micro's total liability for
all claims will not exceed the price paid for the hardware product.
FCC Statement: This equipment has been tested and found to comply with the limits for a Class
A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the manufacturer’s instruction manual, may cause harmful
interference with radio communications. Operation of this equipment in a residential area is likely
to cause harmful interference, in which case you will be required to correct the interference at your
own expense.
WARNING: Handling of lead solder materials used in this
product may expose you to lead, a chemical known to
the State of California to cause birth defects and other
reproductive harm.
Manual Revision 1.0
Release Date: March 11, 2008
Unless you request and receive written permission from SUPER MICRO COMPUTER, you may not
copy any part of this document.
Information in this document is subject to change without notice. Other products and companies
referred to herein are trademarks or registered trademarks of their respective companies or mark
holders.
Copyright © 2008 by SUPER MICRO COMPUTER INC.
All rights reserved.
Printed in the United States of America
Preface
About This Manual
This manual is written for professional system integrators and PC technicians. It
provides information for the installation and use of the SuperServer 6015W-Ni. In-
stallation and maintenance should be performed by experienced technicians only.
Manual Organization
Chapter 1: Introduction
The fi rst chapter provides a checklist of the main components included with the
server system and describes the main features of the SUPER X7DWU serverboard
and the SC812L-520U chassis, which make up the SuperServer 6015W-Ni.
Preface
Chapter 2: Server Installation
This chapter describes the steps necessary to install the SuperServer 6015W-Ni
into a rack and check out the server confi guration prior to powering up the system.
If your server was ordered without processor and memory components, this chapter
will refer you to the appropriate sections of the manual for their installation.
Chapter 3: System Interface
Refer here for details on the system interface, which includes the functions and
information provided by the control panel on the chassis as well as other LEDs
located throughout the system.
Chapter 4: System Safety
You should thoroughly familiarize yourself with this chapter for a general overview
of safety precautions that should be followed when installing and servicing the
SuperServer 6015W-Ni.
iii
SUPER SERVER 6015W-Ni Manual
Chapter 5: Advanced Serverboard Setup
Chapter 5 provides detailed information on the X7DWU serverboard, including the
locations and functions of connectors, headers and jumpers. Refer to this chapter
when adding or removing processors or main memory and when reconfi guring the
serverboard.
Chapter 6: Advanced Chassis Setup
Refer to Chapter 6 for detailed information on the 1U SC812L-520U rackmount
server chassis. You should follow the procedures given in this chapter when install-
ing, removing or reconfi guring peripheral drives and when replacing the system
power supply unit and cooling fans.
Chapter 7: BIOS
The BIOS chapter includes an introduction to BIOS and provides detailed informa-
tion on running the CMOS Setup Utility.
Appendix A: BIOS POST Messages
Appendix B: BIOS POST Codes
Appendix C: System Specifi cations
iv
Notes
Preface
v
SUPER SERVER 6015W-Ni Manual
Table of Contents
Chapter 1 Introduction
1-1 Overview ......................................................................................................... 1-1
1-2 Serverboard Features ..................................................................................... 1-2
Processors ...................................................................................................... 1-2
Memory ........................................................................................................... 1-2
UIO ................................................................................................................. 1-2
Serial ATA ........................................................................................................ 1-2
Onboard Controllers/Ports .............................................................................. 1-2
1-3 Server Chassis Features ................................................................................ 1-4
System Power ................................................................................................. 1-4
Control Panel .................................................................................................. 1-4
I/O Backplane .................................................................................................. 1-4
Cooling System ............................................................................................... 1-4
1-4 Contacting Supermicro .................................................................................... 1-5
Chapter 2 Server Installation
2-1 Overview ......................................................................................................... 2-1
2-2 Unpacking the System .................................................................................... 2-1
2-3 Preparing for Setup ......................................................................................... 2-1
Choosing a Setup Location ............................................................................. 2-1
Rack Precautions ............................................................................................ 2-2
Server Precautions .......................................................................................... 2-2
Rack Mounting Considerations ....................................................................... 2-3
Ambient Operating Temperature ................................................................ 2-3
Reduced Airfl ow ......................................................................................... 2-3
Mechanical Loading ................................................................................... 2-3
Circuit Overloading ..................................................................................... 2-3
Reliable Ground ......................................................................................... 2-3
2-4 Installing the System into a Rack ................................................................... 2-4
Identifying the Sections of the Rack Rails ...................................................... 2-4
Installing the Chassis Rails ............................................................................. 2-5
Installing the Rack Rails ................................................................................. 2-5
Installing the Server into the Rack .................................................................. 2-6
Installing the Server into a Telco Rack ........................................................... 2-7
2-5 Checking the Serverboard Setup .................................................................... 2-8
2-6 Checking the Drive Bay Setup ........................................................................ 2-9
vi
Table of Contents
Chapter 3 System Interface
3-1 Overview ......................................................................................................... 3-1
3-2 Control Panel Buttons ..................................................................................... 3-1
Reset ............................................................................................................... 3-1
Power .............................................................................................................. 3-1
UID .................................................................................................................. 3-1
3-3 Control Panel LEDs ........................................................................................ 3-2
Universal Information LED .............................................................................. 3-2
NIC2 ................................................................................................................ 3-3
NIC1 ................................................................................................................ 3-3
HDD ................................................................................................................. 3-3
Power .............................................................................................................. 3-3
Chapter 4 System Safety
4-1 Electrical Safety Precautions .......................................................................... 4-1
4-2 General Safety Precautions ............................................................................ 4-2
4-3 ESD Precautions ............................................................................................. 4-3
4-4 Operating Precautions .................................................................................... 4-4
Chapter 5 Advanced Serverboard Setup
5-1 Handling the Serverboard ............................................................................... 5-1
Precautions ..................................................................................................... 5-1
Unpacking ....................................................................................................... 5-1
5-2 Processor and Heatsink Installation ............................................................... 5-2
5-3 Connecting Cables .......................................................................................... 5-5
Connecting Data Cables ................................................................................. 5-5
Connecting Power Cables .............................................................................. 5-5
Connecting the Control Panel ......................................................................... 5-5
5-4 I/O Ports .......................................................................................................... 5-6
5-5 Installing Memory ............................................................................................ 5-7
5-6 PCI Expansion Cards ...................................................................................... 5-9
5-7 Serverboard Details ...................................................................................... 5-10
X7DWU Quick Reference ..............................................................................5-11
5-8 Connector Defi nitions .................................................................................... 5-12
5-9 Jumper Settings ............................................................................................ 5-19
5-10 Onboard Indicators ........................................................................................ 5-21
5-11 Floppy, IDE and SATA Drive Connections .................................................... 5-22
5-12 Installing Software ......................................................................................... 5-24
Supero Doctor III ........................................................................................... 5-25
vii
SUPER SERVER 6015W-Ni Manual
Chapter 6 Advanced Chassis Setup
6-1 Static-Sensitive Devices .................................................................................. 6-1
Precautions ..................................................................................................... 6-1
6-2 Control Panel .................................................................................................. 6-2
6-3 System Fans ................................................................................................... 6-2
System Fan Failure ......................................................................................... 6-3
6-4 Drive Bay Installation/Removal ....................................................................... 6-4
Accessing the Drive Bays ............................................................................... 6-4
6-5 Power Supply .................................................................................................. 6-6
Power Supply Failure ...................................................................................... 6-6
Chapter 7 BIOS
7-1 Introduction ...................................................................................................... 7-1
7-2 Running Setup ................................................................................................ 7-2
7-3 Main BIOS Setup ............................................................................................ 7-2
7-4 Advanced Setup .............................................................................................. 7-7
7-5 Security ......................................................................................................... 7-23
7-6 TPM State ..................................................................................................... 7-24
7-7 Boot ............................................................................................................... 7-25
7-8 Exit ................................................................................................................ 7-26
Appendix A BIOS POST Messages
Appendix B BIOS POST Codes
Appendix C System Specifi cations
viii
Chapter 1: Introduction
Chapter 1
Introduction
1-1 Overview
Supermicro's SuperServer 6015W-Ni is an economic, dual processor 1U rackmount
server. The SuperServer 6015W-Ni is comprised of two main subsystems: the
SC812L-520U 1U rackmount chassis and the X7DWU dual processor serverboard.
Please refer to our web site for information on operating systems that have been
certifi ed for use with the SuperServer 6015W-Ni. (www.supermicro.com)
In addition to the mainboard and chassis, various hardware components may have
been included with your SuperServer 6015W-Ni, as listed below:
Two (2) CPU heatsinks (SNK-P0017)
Two (2) 10-cm blower fans (FAN-0059L4)
One (1) air shroud (MCP-310-00008-01)
Two (2) riser cards (RSC-R1UU-2E8 and RSC-R1UU-E8R+)
SATA Accessories:
One (1) 48-cm SATA cable (CBL-0206L)
One (1) 59-cm SATA cable (CBL-0207L)
One (1) 70-cm SATA cable (CBL-0208L)
Rackmount hardware with screws (CSE-PT34)
Two (2) rack rail assemblies
Six (6) brackets for mounting the rack rails to a rack/telco rack
One (1) CD-ROM containing drivers and utilities:
SuperServer 6015W-Ni User's Manual
1-1
SUPER SERVER 6015W-Ni Manual
1-2 Serverboard Features
At the heart of the SuperServer 6015W-Ni lies the X7DWU, a dual processor
serverboard based on Intel's 5400 chipset. Below are the main features of the
X7DWU (see Figure 1-1 for a block diagram of the chipset).
Processors
The X7DWU supports single or dual 771-pin Intel Xeon 5400/5300LV/5200/5100LV
series processors at a FSB speed of 1600/1333/1066 MHz. Please refer to the
serverboard description pages on our web site for a complete listing of supported
processors.
Memory
The X7DWU has eight 240-pin DIMM sockets that can support up to 64 GB of
ECC FBD (Fully Buffered DIMM) DDR2-800 (fully supported with 1600 MHz CPUs
only), DDR2-667 or DDR2-533 SDRAM. The memory is an interleaved confi gura-
tion, which requires modules of the same size and speed to be installed in pairs.
Please refer to Chapter 5 for memory speed jumper settings.
UIO
The X7DWU is a specially-designed serverboard that features Supermicro's UIO
(Universal I/O) technology. UIO serverboards have a PCI-Express x8 connector that
can support any one of several types of UIO card types to add SAS ports, additional
LAN ports, etc. to the serverboard. This allows the user to tailor the serverboard
to their own needs.
Serial ATA
An on-chip (ESB2) SATA controller is integrated into the X7DWU to provide a six-
port, 3 Gb/sec Serial ATA subsystem, which is RAID 0, 1 and 10 supported (RAID 5
also supported with Windows OS). The SATA drives are hot-swappable units. Note:
The operating system you use must have RAID support to enable the hot-swap
capability and RAID function of the Serial ATA drives.
Onboard Controllers/Ports
One fl oppy drive controller and one onboard ATA/100 controller are provided to
support up to two IDE hard drives or ATAPI devices. The color-coded I/O ports
include one COM port, a VGA (monitor) port, two USB 2.0 ports, PS/2 mouse and
keyboard ports and two gigabit Ethernet ports.
1-2
Chapter 1: Introduction
ATI Graphics Controller
The X7DWU features an integrated ATI video controller based on the ES1000 graph-
ics chip. The ES1000 was designed specifi cally for servers, featuring low power
consumption, high reliability and superior longevity.
Other Features
Other onboard features that promote system health include onboard voltage moni-
tors, a chassis intrusion header, auto-switching voltage regulators, chassis and CPU
overheat sensors, virus protection and BIOS rescue.
Figure 1-1. Intel 5400 Chipset:
System Block Diagram
Note: This is a general block diagram. Please see Chapter 5 for details.
1-3
SUPER SERVER 6015W-Ni Manual
1-3 Server Chassis Features
The SC812L-520U is Supermicro's second-generation 1U chassis and features
three hard drive bays, two front side USB ports and a revolutionary cooling design
that can keep today's most powerful processors running well below their temperature
thresholds. The following is a general outline of the main features of the SC812L-
520U chassis.
System Power
When confi gured as a SuperServer 6015W-Ni, the SC812L-520U chassis includes
a 520W power supply.
Control Panel
The SC812L-520U control panel provides important system monitoring and control
information. LEDs indicate power on, network activity, hard disk drive activity, UID
and system overheat conditions. Also present are a main power button, a system
reset button and a UID button.
I/O Backplane
The SC812L-520U is a 1U rackmount chassis. Its I/O backplane provides three
standard size PCI slots, one COM port (the other is internal), one VGA port, two USB
ports, PS/2 mouse and keyboard ports, two Ethernet (LAN) ports and a UID LED.
Cooling System
The SC812L-520U chassis' revolutionary cooling design has been optimized to
provide suffi cient cooling for dual CPU confi gurations. The SC812L-520U includes
two heavy duty 10-cm blower fans located in the middle of the chassis. There is a
"Fan Speed Control Mode" in BIOS that allows chassis fan speed to be determined
by system temperature. An overheat LED will be activated if a fan fails and the
ambient air temperature inside the chassis rises.
1-4
Chapter 1: Introduction
1-4 Contacting Supermicro
Headquarters
Address: Super Micro Computer, Inc.
980 Rock Ave.
San Jose, CA 95131 U.S.A.
Tel: +1 (408) 503-8000
Fax: +1 (408) 503-8008
Email: marketing@supermicro.com (General Information)
support@supermicro.com (Technical Support)
Web Site: www.supermicro.com
Europe
Address: Super Micro Computer, B.V.
Het Sterrenbeeld 28, 5215 ML
's-Hertogenbosch, The Netherlands
Tel: +31 (0) 73-6400390
Fax: +31 (0) 73-6416525
Email: sales@supermicro.nl (General Information)
support@supermicro.nl (Technical Support)
rma@supermicro.nl (Customer Support)
Asia-Pacifi c
Address: Super Micro Computer, Inc.
4F, No. 232-1, Liancheng Rd.
Chung-Ho 235, Taipei County
Taiwan, R.O.C.
Tel: +886-(2) 8226-3990
Fax: +886-(2) 8226-3991
Web Site: www.supermicro.com.tw
Technical Support:
Email: support@supermicro.com.tw
Tel: 886-2-8228-1366, ext.132 or 139
1-5
SUPER SERVER 6015W-Ni Manual
Notes
1-6
Chapter 2: Server Installation
Chapter 2
Server Installation
2-1 Overview
This chapter provides a quick setup checklist to get your SuperServer 6015W-Ni
up and running. Following these steps in the order given should enable you to
have the system operational within a minimum amount of time. This quick setup
assumes that your SuperServer 6015W-Ni system has come to you with the proces-
sors and memory preinstalled. If your system is not already fully integrated with a
serverboard, processors, system memory etc., please turn to the chapter or section
noted in each step for details on installing specifi c components.
2-2 Unpacking the System
You should inspect the box the SuperServer 6015W-Ni was shipped in and note
if it was damaged in any way. If the server itself shows damage you should fi le a
damage claim with the carrier who delivered it.
Decide on a suitable location for the rack unit that will hold the SuperServer 6015W-
Ni. It should be situated in a clean, dust-free area that is well ventilated. Avoid
areas where heat, electrical noise and electromagnetic fi elds are generated. You
will also need it placed near a grounded power outlet. Read the Rack and Server
Precautions in the next section.
2-3 Preparing for Setup
The box the SuperServer 6015W-Ni was shipped in should include two sets of rail
assemblies, two rail mounting brackets and the mounting screws you will need to
install the system into the rack. Follow the steps in the order given to complete
the installation process in a minimum amount of time. Please read this section in
its entirety before you begin the installation procedure outlined in the sections that
follow.
Choosing a Setup Location
Leave enough clearance in front of the rack to enable you to open the front door
•
completely (~25 inches) and approximately 30 inches of clearance in the back
of the rack to allow for suffi cient airfl ow and ease in servicing.This product is for
2-1
S
UPERS ERVER 6015W-Ni Manual
installation only in a Restricted Access Location (dedicated equipment rooms,
service closets and the like).
!
This product is not suitable for use with visual display work place devices
•
acccording to §2 of the the German Ordinance for Work with Visual Display
Units.
Warnings and Precautions!
!
Rack Precautions
•
Ensure that the leveling jacks on the bottom of the rack are fully extended to
the fl oor with the full weight of the rack resting on them.
•
In single rack installation, stabilizers should be attached to the rack. In multiple
rack installations, the racks should be coupled together.
•
Always make sure the rack is stable before extending a component from the
rack.
•
You should extend only one component at a time - extending two or more si-
multaneously may cause the rack to become unstable.
Server Precautions
•
Review the electrical and general safety precautions in Chapter 4.
•
Determine the placement of each component in the rack before you install the
rails.
•
Install the heaviest server components on the bottom of the rack fi rst, and then
work up.
•
Use a regulating uninterruptible power supply (UPS) to protect the server from
power surges, voltage spikes and to keep your system operating in case of a
power failure.
2-2
Chapter 2: Server Installation
Allow the hot plug SATA drives and power supply modules to cool before touch-
•
ing them.
•
Always keep the rack's front door and all panels and components on the servers
closed when not servicing to maintain proper cooling.
Rack Mounting Considerations
Ambient Operating Temperature
If installed in a closed or multi-unit rack assembly, the ambient operating tempera-
ture of the rack environment may be greater than the ambient temperature of the
room. Therefore, consideration should be given to installing the equipment in an
environment compatible with the manufacturer’s maximum rated ambient tempera-
ture (Tmra).
Reduced Airfl ow
Equipment should be mounted into a rack so that the amount of airfl ow required
for safe operation is not compromised.
Mechanical Loading
Equipment should be mounted into a rack so that a hazardous condition does not
arise due to uneven mechanical loading.
Circuit Overloading
Consideration should be given to the connection of the equipment to the power
supply circuitry and the effect that any possible overloading of circuits might have
on overcurrent protection and power supply wiring. Appropriate consideration of
equipment nameplate ratings should be used when addressing this concern.
Reliable Ground
A reliable ground must be maintained at all times. To ensure this, the rack itself
should be grounded. Particular attention should be given to power supply connec-
tions other than the direct connections to the branch circuit (i.e. the use of power
strips, etc.).
2-3
S
UPERS ERVER 6015W-Ni Manual
2-4 Installing the System into a Rack
This section provides information on installing the SuperServer 6015W-Ni into a
rack. If the 6015W-Ni has already been mounted into a rack, you can skip ahead
to Sections 2-5 and 2-6.
There are a variety of rack units on the market, which may mean the assembly
procedure will differ slightly. The following is a guideline for installing the 6015W-
Ni into a rack with the rack rails provided. You should also refer to the installation
instructions that came with the rack unit you are using.
Identifying the Sections of the Rack Rails
You should have received two rack rail assemblies with the SuperServer 6015W-Ni.
Each of these assemblies consist of three sections: an inner fi xed chassis rail that
secures to the 6015W-Ni (A) and an outer fi xed rack rail that secures directly to
the rack itself (B). A sliding rail guide sandwiched between the two should remain
attached to the fi xed rack rail (see Figure 2-1). The A and B rails must be detached
from each other to install.
To remove the fi xed chassis rail (A), pull it out as far as possible - you should hear
a "click" sound as a locking tab emerges from inside the rail assembly and locks
the inner rail. Then depress the locking tab to pull the inner rail completely out. Do
this for both the left and right side rack rail assemblies.
Figure 2-1. Identifying the Sections of the Rack Rails
Mounting Holes
Locking Tab
B
A
2-4
Chapter 2: Server Installation
Installing the Chassis Rails
Position the fi xed chassis rail sections you just removed along the side of the
6015W-Ni making sure the screw holes line up. Note that these two rails are left/right
specifi c. Screw the rail securely to the side of the chassis (see Figure 2-2). Repeat
this procedure for the other rail on the other side of the chassis. You will also need
to attach the rail brackets when installng into a telco rack.
Locking Tabs: As you have seen, both chassis rails have a locking tab, which
serves two functions. The fi rst is to lock the server into place when installed and
pushed fully into the rack, which is its normal position. Secondly, these tabs also
lock the server in place when fully extended from the rack. This prevents the server
from coming completely out of the rack when you pull it out for servicing.
Figure 2-2. Installing Chassis Rails
Installing the Rack Rails
Determine where you want to place the SuperServer 6015W-Ni in the rack. (See
Rack and Server Precautions in Section 2-3.) Position the fi xed rack rail/sliding rail
guide assemblies at the desired location in the rack, keeping the sliding rail guide
facing the inside of the rack. Screw the assembly securely to the rack using the
brackets provided. Attach the other assembly to the other side of the rack, making
sure both are at the exact same height and with the rail guides facing inward.
2-5
S
UPERS ERVER 6015W-Ni Manual
Installing the Server into the Rack
You should now have rails attached to both the chassis and the rack unit. The next
step is to install the server into the rack. Do this by lining up the rear of the chassis
rails with the front of the rack rails. Slide the chassis rails into the rack rails, keeping
the pressure even on both sides (you may have to depress the locking tabs when
inserting). See Figure 2-3.
When the server has been pushed completely into the rack, you should hear the
locking tabs "click". Finish by inserting and tightening the thumbscrews that hold
the front of the server to the rack.
Figure 2-3. Installing the Server into a Rack
2-6
Chapter 2: Server Installation
Installing the Server into a Telco Rack
To install the SuperServer 6015W-Ni into a Telco type rack, use two L-shaped
brackets on either side of the chassis (four total). First, determine how far follow
the server will extend out the front of the rack. Larger chassis should be positioned
to balance the weight between front and back. If a bezel is included on your server,
remove it. Then attach the two front brackets to each side of the chassis, then the
two rear brackets positioned with just enough space to accommodate the width of
the telco rack. Finish by sliding the chassis into the rack and tightening the brackets
to the rack.
Figure 2-4. Installing the Server into a Telco Rack
2-7
S
UPERS ERVER 6015W-Ni Manual
2-5 Checking the Serverboard Setup
After you install the 6015W-Ni in the rack, you will need to open the unit to make sure
the serverboard is properly installed and all the connections have been made.
Accessing the Inside of the System
Grasp the two handles on either side and pull the unit straight out until it
1.
locks (you will hear a "click").
Depress the two buttons on the top of the chassis to release the top cover.
2.
There is a large rectangular recess in the middle front of the top cover to help
you push the cover away from you until it stops.
Lift the top cover from the chassis to gain full access to the inside of the
3.
server. See Figure 2-5.
Checking the Components
You should have one or two processors already installed into the serverboard.
1.
Each processor needs its own heatsink. See Chapter 5 for instructions on
processor and heatsink installation.
Your 6015W-Ni server system may have come with system memory already
2.
installed. Make sure all DIMMs are fully seated in their slots. For details on
adding system memory, refer to Chapter 5.
If desired, you can install add-on cards to the system. See Chapter 5 for
3.
details on installing PCI add-on cards.
Make sure all power and data cables are properly connected and not block-
4.
ing the chassis airfl ow. See Chapter 5 for details on cable connections. Also,
check the air seals for damage. The air seals are located under the blower
fan and beneath the frame cross section that separates the drive bay area
from the serverboard area of the chassis.
2-8
Chapter 2: Server Installation
2-6 Checking the Drive Bay Setup
Next, you should check to make sure the hard drives have been properly installed
and all connections have been made.
Checking the Drives
For servicing the hard drives, you will need to remove the top chassis cover.
1.
If you need to remove or install hard drives, please refer to Chapter 6.
2.
Checking the Airfl ow
Airfl ow is provided by two heavy-duty 10-cm blower fans. The system com-
1.
ponent layout was carefully designed to direct suffi cient cooling airfl ow to the
components that generate the most heat.
Note that all power and data cables have been routed in such a way that they
2.
do not block the airfl ow generated by the fans.
Providing Power
The last thing you must do is to provide input power to the system. Plug the
1.
power cord from the power supply unit into a high-quality power strip that of-
fers protection from electrical noise and power surges. It is recommended that
you use an uninterruptible power supply (UPS).
Turn on the power switch on the back of the power supply, then depress the
2.
power button on the front chassis control panel.
2-9
S
UPERS ERVER 6015W-Ni Manual
Figure 2-5. Accessing the Inside of the SuperServer 6015W-Ni
2-10
Chapter 3: System Interface
Chapter 3
System Interface
3-1 Overview
There are several LEDs on the control panel to keep you constantly informed of the
overall status of the system. There are also three buttons on the chassis control
panel.
3-2 Control Panel Buttons
There are three buttons located on the front of the chassis: a reset button, a power
on/off button and a UID button.
Reset
Use the reset button to reboot the system.
Power
This is the main power button, which is used to apply or turn off the main system
power. Turning off system power with this button removes the main power but keeps
standby power supplied to the system.
UID
Depressing the UID (unit identifi er) button illuminates an LED on both the front
and rear of the chassis for easy system location in large stack confi gurations. The
LED will remain on until the button is pushed a second time. Another UID button
on the rear of the chassis serves the same function. See the table in Figure 3-1 for
descriptions of UID LED states.
3-1
S
UPERS ERVER 6015W-Ni Manual
3-3 Control Panel LEDs
The control panel located on the front of the SC812L-520U chassis has fi ve LEDs.
These LEDs provide you with critical information related to different parts of the
system. This section explains what each LED indicates when illuminated and any
corrective action you may need to take.
Universal Information LED
When this LED blinks red quickly, it indicates a fan failure and when blinking red
slowly a power failure. This LED will be blue when used for UID (Unit Identifi er).
When on continuously it indicates an overheat condition, which may be caused by
cables obstructing the airfl ow in the system or the ambient room temperature being
too warm. Check the routing of the cables and make sure all fans are present and
operating normally. You should also check to make sure that the chassis covers
are installed. Finally, verify that the heatsinks are installed properly (see Chapter
5). This LED will remain fl ashing or on as long as the indicated condition exists.
See the table below for descriptions of the LED states.
Figure 3-1. Universal Information LED States
Universal Information LED States
State Indication
Fast Blinking Red (1x/sec) Fan Fail
Solid Red CPU Overheat
Slow Blinking Red (1x/4 sec) Power Fail
Solid Blue Local UID Button Depressed
Blinking Blue IPMI-Activated UID
Note: deactivating the UID LED must be performed in the same way it was acti-
vated. (If the UID LED was activated via IPMI, you can only turn the LED off via
IPMI and not with the UID button.)
3-2
NIC2
Indicates network activity on LAN2 when fl ashing.
NIC1
Indicates network activity on LAN1 when fl ashing.
Chapter 3: System Interface
HDD
Indicates IDE channel activity when fl ashing.
Power
Indicates power is being supplied to the system's power supply units. This LED
should normally be illuminated when the system is operating.
3-3
S
UPERS ERVER 6015W-Ni Manual
Notes
3-4
Chapter 4: System Safety
Chapter 4
System Safety
4-1 Electrical Safety Precautions
!
Basic electrical safety precautions should be followed to protect yourself from harm
and the SuperServer 6015W-Ni from damage:
Be aware of the locations of the power on/off switch on the chassis as well
•
as the room's emergency power-off switch, disconnection switch or electrical
outlet. If an electrical accident occurs, you can then quickly remove power from
the system.
Do not work alone when working with high voltage components.
•
Power should always be disconnected from the system when removing or in-
•
stalling main system components, such as the serverboard, memory modules
and fl oppy drive. When disconnecting power, you should fi rst power down the
system with the operating system fi rst and then unplug the power cords of all
the power supply units in the system.
When working around exposed electrical circuits, another person who is familiar
•
with the power-off controls should be nearby to switch off the power if neces-
sary.
Use only one hand when working with powered-on electrical equipment. This
•
is to avoid making a complete circuit, which will cause electrical shock. Use
extreme caution when using metal tools, which can easily damage any electrical
components or circuit boards they come into contact with.
Do not use mats designed to decrease static electrical discharge as protection
•
from electrical shock. Instead, use rubber mats that have been specifi cally
designed as electrical insulators.
The power supply power cords must include a grounding plug and must be
•
plugged into grounded electrical outlets.
4-1
S
UPERS ERVER 6015W-Ni Manual
Serverboard Battery: CAUTION - There is a danger of explosion if the onboard
•
battery is installed upside down, which will reverse its polarites (see Figure
4-1). This battery must be replaced only with the same or an equivalent type
recommended by the manufacturer. Dispose of used batteries according to the
manufacturer's instructions.
•
CD-ROM Laser: CAUTION - this server may have come equipped with a CD-
ROM drive. To prevent direct exposure to the laser beam and hazardous radia-
tion exposure, do not open the enclosure or use the unit in any unconventional
way.
•
Mainboard replaceable soldered-in fuses: Self-resetting PTC (Positive Tempera-
ture Coeffi cient) fuses on the mainboard must be replaced by trained service
technicians only. The new fuse must be the same or equivalent as the one
replaced. Contact technical support for details and support.
4-2 General Safety Precautions
!
Follow these rules to ensure general safety:
Keep the area around the 6015W-Ni clean and free of clutter.
•
The 6015W-Ni weighs approximately 33 lbs. (15 kg.) when fully loaded. When
•
lifting the system, two people at either end should lift slowly with their feet
spread out to distribute the weight. Always keep your back straight and lift with
your legs.
Place the chassis top cover and any system components that have been re-
•
moved away from the system or on a table so that they won't accidentally be
stepped on.
While working on the system, do not wear loose clothing such as neckties and
•
unbuttoned shirt sleeves, which can come into contact with electrical circuits or
be pulled into a cooling fan.
Remove any jewelry or metal objects from your body, which are excellent metal
•
conductors that can create short circuits and harm you if they come into contact
with printed circuit boards or areas where power is present.
4-2