Supero SUPERSERVER 6015C-M3, SUPERSERVER 6015C-MT User Manual

SUPER
SUPERSERVER 6015C-M3 SUPERSERVER 6015C-MT
®
USER’S MANUAL
Revision 1.0a
The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccuracies that may be contained in this document, makes no commitment to update or to keep current the information in this manual, or to notify any person or organization of the updates. Please Note: For the most up-to-date version of this
manual, please see our web site at www.supermicro.com.
Super Micro Computer, Inc. ("Supermicro") reserves the right to make changes to the product described in this manual at any time and without notice. This product, including software, if any, and documentation may not, in whole or in part, be copied, photocopied, reproduced, translated or reduced to any medium or machine without prior written consent.
IN NO EVENT WILL SUPERMICRO BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL, SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO USE THIS PRODUCT OR DOCUMENTATION, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. IN PARTICULAR, SUPERMICRO SHALL NOT HAVE LIABILITY FOR ANY HARDWARE, SOFTW ARE, OR DA TA STORED OR USED WITH THE PRODUCT, INCLUDING THE COSTS OF REPAIRING, REPLACING, INTEGRATING, INSTALLING OR RECOVERING SUCH HARDWARE, SOFTWARE, OR DATA.
Any disputes arising between manufacturer and customer shall be governed by the laws of Santa Clara County in the State of California, USA. The State of California, County of Santa Clara shall be the exclusive venue for the resolution of any such disputes. Super Micro's total liability for all claims will not exceed the price paid for the hardware product.
FCC Statement: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the manufacturer’s instruction manual, may cause harmful interference with radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case you will be required to correct the interference at your own expense.
California Best Management Practices Regulations for Perchlorate Materials: This Perchlorate warning applies only to products containing CR (Manganese Dioxide) Lithium coin cells. “Perchlorate Material-special handling may apply. See www.dtsc.ca.gov/hazardouswaste/perchlorate”
WARNING: Handling of lead solder materials used in this product may expose you to lead, a chemical known to the State of California to cause birth defects and other reproductive harm.
Manual Revision 1.0a Release Date: October 6, 2008
Unless you request and receive written permission from Super Micro Computer, Inc., you may not copy any part of this document.
Information in this document is subject to change without notice. Other products and companies referred to herein are trademarks or registered trademarks of their respective companies or mark holders.
Copyright © 2008 by Super Micro Computer, Inc. All rights reserved.
Printed in the United States of America
Preface
About This Manual
This manual is written for professional system integrators and PC technicians. It provides information for the installation and use of the SuperServer 6015C­M3/6015C-MT. Installation and maintenance should be performed by experienced technicians only.
The SuperServer 6015C-M3/6015C-MT is a high-end dual processor rackmount server based on the SC813MTQ-520C 1U rackmount server chassis and the Su­per X7DCL-3/X7DCL-i serverboard. The X7DCL-3/X7DCL-i supports dual Intel 5200/5100 Series processors in LGA771 sockets.
Preface
®
Manual Organization
Chapter 1: Introduction
The fi rst chapter provides a checklist of the main components included with the server system and describes the main features of the Super X7DCL-3/X7DCL-i serverboard and the SC813MTQ-520C chassis.
Chapter 2: Server Installation
This chapter describes the steps necessary to install the SuperServer 6015C­M3/6015C-MT into a rack and check out the server confi guration prior to powering up the system. If your server was ordered without the processor and memory components, this chapter will refer you to the appropriate sections of the manual for their installation.
Chapter 3: System Interface
Refer to this chapter for details on the system interface, which includes the functions and information provided by the control panel on the chassis as well as other LEDs located throughout the system.
iii
SUPERSERVER 6015C-M3/6015C-MT User's Manual
Chapter 4: System Safety
You should thoroughly familiarize yourself with this chapter for a general overview of safety precautions that should be followed when installing and servicing the SuperServer 6015C-M3/6015C-MT.
Chapter 5: Advanced Serverboard Setup
Chapter 5 provides detailed information on the X7DCL-3/X7DCL-i serverboard, including the locations and functions of connectors, headers and jumpers. Refer to this chapter when adding or removing processors or main memory and when reconfi guring the serverboard.
Chapter 6: Advanced Chassis Setup
Refer to Chapter 6 for detailed information on the SC813MTQ-520C 1U rackmount server chassis. You should follow the procedures given in this chapter when install­ing, removing or reconfi guring SAS/SATA or peripheral drives and when replacing system power supply units and cooling fans.
Chapter 7: BIOS
The BIOS chapter includes an introduction to BIOS and provides detailed informa­tion on running the CMOS Setup Utility.
Appendix A: BIOS POST Messages
Appendix B: BIOS POST Codes
Appendix C: Intel HostRAID Setup Guidelines
Appendix D: Software Installation
Appendix E: System Specifi cations
iv
Notes
Preface
v
SUPERSERVER 6015C-M3/6015C-MT User's Manual
Table of Contents
Chapter 1 Introduction
1-1 Overview .........................................................................................................1-1
1-2 Serverboard Features .....................................................................................1-2
Processors ......................................................................................................1-2
Memory ...........................................................................................................1-2
Onboard SAS (6015C-M3) ..............................................................................1-2
Serial ATA ........................................................................................................ 1-2
PCI Expansion Slots ....................................................................................... 1-2
Ethernet Ports .................................................................................................1-3
Onboard Controllers/Ports .............................................................................. 1-3
Other Features ................................................................................................1-3
1-3 Server Chassis Features ................................................................................ 1-5
System Power .................................................................................................1-5
SAS/SATA Subsystem .....................................................................................1-5
Control Panel .................................................................................................. 1-5
Rear I/O Panel ................................................................................................1-5
Cooling System ...............................................................................................1-5
1-4 Contacting Supermicro ....................................................................................1-6
Chapter 2 Server Installation
2-1 Overview .........................................................................................................2-1
2-2 Unpacking the System ....................................................................................2-1
2-3 Preparing for Setup ......................................................................................... 2-1
Choosing a Setup Location ............................................................................. 2-1
Rack Precautions ............................................................................................2-2
Server Precautions .......................................................................................... 2-2
Rack Mounting Considerations .......................................................................2-3
Ambient Operating Temperature ................................................................ 2-3
Reduced Airfl ow ......................................................................................... 2-3
Mechanical Loading ................................................................................... 2-3
Circuit Overloading ..................................................................................... 2-3
Reliable Ground ......................................................................................... 2-3
2-4 Installing the System into a Rack ................................................................... 2-4
Identifying the Sections of the Rack Rails ...................................................... 2-4
Installing the Rear Inner Rails ........................................................................ 2-4
Installing the Rack Rails .................................................................................2-5
Installing the Server into the Rack ..................................................................2-6
vi
Table of Contents
Installing the Server into a Telco Rack ........................................................... 2-7
2-5 Checking the Serverboard Setup ....................................................................2-8
2-6 Checking the Chassis Setup .........................................................................2-10
Chapter 3 System Interface
3-1 Overview .........................................................................................................3-1
3-2 Control Panel Buttons .....................................................................................3-1
Reset ...............................................................................................................3-1
Power ..............................................................................................................3-1
3-3 Control Panel LEDs ........................................................................................3-2
Overheat/Fan Fail ........................................................................................... 3-2
NIC2 ................................................................................................................3-2
NIC1 ................................................................................................................3-2
HDD ................................................................................................................. 3-2
Power ..............................................................................................................3-3
3- 4 Drive C arr ier LED s .........................................................................................3-3
SAS Drives (6015C-M3) ................................................................................. 3-3
SATA Drives (6015C-MT) ................................................................................ 3-3
Chapter 4 System Safety
4-2 General Safety Precautions ............................................................................4-2
4-3 ESD Precautions ............................................................................................. 4-3
4-4 Operating Precautions .................................................................................... 4-4
Chapter 5 Advanced Serverboard Setup
5-1 Handling the Serverboard ...............................................................................5-1
Precautions .....................................................................................................5-1
Unpacking .......................................................................................................5-2
5-2 Serverboard Installation ..................................................................................5-2
5-3 Connecting Cables .......................................................................................... 5-3
Connecting Data Cables .................................................................................5-3
Connecting Power Cables .............................................................................. 5-3
Connecting the Control Panel ......................................................................... 5-4
5-4 I/O Ports .......................................................................................................... 5-4
5-5 Processor and Heatsink Installation................................................................5-5
5-6 Installing Memory ............................................................................................5-8
5-7 Adding PCI Cards ........................................................................................... 5-9
5-8 Serverboard Details ...................................................................................... 5-10
Motherboard Layout ......................................................................................5-10
X7DCL-3/X7DCL-i Quick Reference ..............................................................5-11
5-9 Connector Defi nitions ................................................................................... 5-12
vii
SUPERSERVER 6015C-M3/6015C-MT User's Manual
ATX Power Connector .............................................................................. 5-12
Processor Power Connector ................................................................... 5-12
PW_ON Connector ................................................................................... 5-12
Reset Connector ...................................................................................... 5-12
Overheat LED (OH) .................................................................................. 5-13
NIC2 (LAN2) LED ..................................................................................... 5-13
NIC1 (LAN1) LED ..................................................................................... 5-13
HDD LED .................................................................................................. 5-13
Power On LED .........................................................................................5-13
NMI Button ............................................................................................... 5-14
Fan Headers ............................................................................................. 5-14
ATX PS/2 Keyboard and PS/2 Mouse Ports ............................................5-14
Chassis Intrusion ...................................................................................... 5-14
LAN1/2 (Ethernet Ports) ........................................................................... 5-14
Universal Serial Bus (USB) ...................................................................... 5-15
Wake-On-LAN ..........................................................................................5-15
Wake-On-Ring ..........................................................................................5-15
Power Supply Fail Detect ......................................................................... 5-16
Alarm Reset .............................................................................................. 5-16
PWR I BPI
2
C ...................................................................................................5-16
2
C ........................................................................................................5-16
Serial Ports ............................................................................................... 5-17
SGPIO Headers ....................................................................................... 5-17
Power LED/Speaker ................................................................................. 5-17
Keylock .....................................................................................................5-17
5-10 Jumper Settings ............................................................................................5-18
Explanation of Jumpers ................................................................................ 5-18
CMOS Clear ............................................................................................. 5-18
VGA Enable/Disable ................................................................................. 5-18
LAN1/LAN2 Enable/Disable ..................................................................... 5-19
SAS Enable/Disable ................................................................................. 5-19
SAS RAID Select ..................................................................................... 5-19
Watch Dog ................................................................................................ 5-19
2
I
C Bus to PCI/PCI-Exp. Slots .................................................................5-20
5-11 Onboard Indicators ........................................................................................5-20
LAN1/LAN2 LEDs ..................................................................................... 5-20
Onboard Power LED (LED3)....................................................................5-20
System Status LED (LED4)......................................................................5-20
CPU_VRM Overheat LED Indicators (LED5/LED6) ................................. 5-21
viii
Table of Contents
5-12 Floppy and IDE Drive Connections...............................................................5-21
Floppy Connector ..................................................................................... 5-21
IDE Connector .......................................................................................... 5-22
SAS Ports ................................................................................................. 5-23
SATA Ports ............................................................................................... 5-23
Chapter 6 Advanced Chassis Setup
6-1 Static-Sensitive Devices ..................................................................................6-1
Precautions .....................................................................................................6-1
Unpacking .......................................................................................................6-1
6-2 Control Panel ..................................................................................................6-2
6-3 System Fans ................................................................................................... 6-3
System Fan Failure ......................................................................................... 6-3
6-4 Drive Bay Installation/Removal ....................................................................... 6-3
Removing the Front Bezel .............................................................................. 6-3
SAS/SATA Drive Installation ............................................................................6-4
Accessing the Drive Bays ............................................................................... 6-4
DVD-ROM Drive Installation ........................................................................... 6-6
6-5 Power Supply ..................................................................................................6-7
Power Supply Failure ...................................................................................... 6-7
Replacing the Power Supply ...........................................................................6-7
Chapter 7 BIOS
7-1 Introduction ......................................................................................................7-1
7-2 Running Setup ................................................................................................ 7-2
7-3 Main BIOS Setup ............................................................................................ 7-2
7-4 Advanced Setup .............................................................................................. 7-7
7-5 Security .........................................................................................................7-20
7-6 Boot ............................................................................................................... 7-21
7-7 Exit ................................................................................................................7-22
Appendix A BIOS POST Messages Appendix B BIOS POST Codes Appendix C Intel HostRAID Setup Guidelines Appendix D Software Installation Appendix E System Specifi cations
ix
SUPERSERVER 6015C-M3/6015C-MT User's Manual
x
Chapter 1: Introduction
Chapter 1
Introduction
1-1 Overview
The SuperServer 6015C-M3/6015C-MT is a dual processor server comprised of two main subsystems: the SC813MTQ-520C 1U rackmount chassis and the X7DCL­3/X7DCL-i serverboard. Please refer to our web site for information on operating systems that have been certifi ed for use with the 6015C-M3/6015C-MT (www. supermicro.com).
In addition to the serverboard and chassis, various hardware components may have been included with the 6015C-M3/6015C-MT, as listed below.
Two CPU heatsinks (SNK-P0017)
One (1) slim DVD-ROM drive [DVM-PNSC-824(B)]
SAS/SATA Accessories: Four (4) SAS/SATA hard drive carriers (CSE-PT-39(B)) One (1) internal SAS/SATA backplane (BPN-SAS-815TQ) One (1) SAS/SATA cable set (CBL-0186L)
One (1) PCI-E x8 riser card (CSE-RR1U-E8)
One (1) front side USB/COM port tray [(CSE-PT-40(B)]
Four (4) 4-cm high-performance fans (FAN-0061)
One (1) air shroud for 1U chassis (MCP-310-00029-01)
Rackmount hardware with screws (CSE-PT52): Two (2) rack rail assemblies Six (6) brackets for mounting the rack rails in a rack/telco rack
One (1) CD containing drivers and utilities
SuperServer 6015C-M3/6015C-MT User's Manual
Note: "B" indicates part is available in black.
1-1
SUPERSERVER 6015C-M3/6015C-MT User's Manual
1-2 Serverboard Features
At the heart of the SuperServer 6015C-M3/6015C-MT lies the X7DCL-3/X7DCL-i, a single processor serverboard based on Intel's 5100 chipset and designed to provide maximum performance. Below are the main features of the X7DCL-3/X7DCL-i.
Processors
The X7DCL-3/X7DCL-i supports dual Intel® 5400, 5300, 5200 or 5100 Series processors in LGA771 sockets. Please refer to our web site for a complete listing of supported processors (www.supermicro.com).
Memory
The X7DCL-3/X7DCL-i has six 240-pin DIMM sockets that can support up to 48 GB of registered ECC DDR2-667/533 SDRAM. Memory must be installed in an interleaved (dual-channel) confi guration. All memory modules used to populate the system should be the same size, type and speed. See Chapter 5 for details.
Onboard SAS (6015C-M3)
An onboard LSI 1068E SAS controller in integrated into the X7DCL-3. The hot­swappable SAS drives are connected to a backplane that provides power, bus termination and confi guration settings.
Note: The operati ng system yo u use must h ave R AID su ppor t to e nable t he hot­swap capabilit y and RAI D function of th e SAS drives. R AID 0, 1, 5 and 10 are supported.
Serial ATA
The Sout h Bridge (IC H9R) of the 5100 chipset i ncludes a Ser ial ATA controlle r. The hot-swappable SATA drives are connected to a backplane that provides power, bus termination and confi guration settings.
Note: The operating system you use must have RAID support to enable the hot-sw ap capab ilit y and R AID fu nctio n of the SAS d rives. R AI D 0, 1, and 10 are supported.
PCI Expansion Slots
The X7DCL-3/X7DCL-i has two PCI-Express x8 slots, one PCI-Express x4 slot (in a x8 slot) and three 32-bit, 33 MHz (5V) PCI slots. In the 6015C-M3/6015C-MT server confi guration, a PCI-E riser card (CSE-RR1U-E8) has been installed to support a single PCI-Express add-on card.
1-2
Chapter 1: Introduction
Ethernet Ports
The X7DCL-3/X7DCL-i has two network controllers integrated into the chipset to support two Gigabit LAN ports (100/1000Base-T/1000BaseTX, RJ45 output).
Onboard Controllers/Ports
An onboard IDE controller supports Ultra ATA 100 hard drives or ATAPI devices. Onboard I/O backpanel ports include one COM port, a VGA port, two USB ports, PS/2 mouse and keyboard ports and two Gigabit LAN (NIC) ports.
Other Features
Other onboard features that promote system health include voltage monitors, a chassis intrusion header, auto-switching voltage regulators, chassis and CPU overheat sensors, virus protection and BIOS rescue.
1-3
SUPERSERVER 6015C-M3/6015C-MT User's Manual
MCH
PROCESSOR#1
1067/1333
MT/S
#0-2
#0-1
#0-3
ISL6312A
PCI-EXP x8
PCI-E x8
PROCESSOR#2
1067/1333
MT/S
PORT
#2,3
Intel 5100
#7
#6
#5
#4
#3
#2
#1
#0
3.0 Gb/S
SAS
RJ45
RJ45
GDDR2 SDRAM 32MB
VGA CONN
LSI 1068E
82573V
82573V
VGA
Volari Z9S
IDE
IT8213F
PCI-33
PCI-33
PCI-33
PCI-EXP x8
PCI-E x8
PCI-EXP x8
PCI-EXP x1
PCI-EXP x1
PCI-E x8 Slot
PCI-E x4Signal
PCI 33MHz
PORT
#4,5
PORT
#6,7
LANE5
LANE6
LANE1/2/3/4
PORT
#0
PCIE X4
DMI
ICH9R
LPC
SIO
W83627HG
MS
KB
COM1
External
DDR2 667
3.0 Gb/S
FWH
#1-3
#1-2
#1-1
DDR2 667
#1
#0
#1
#0
USB 2.0
COM2
INTERNAL/SOL
ISL6312A
#5
#4
#3
#2
SATA
#6
#5
#4
#3
#2
USB
Note: This is a general block diagram. Please see Chapter 5 for details.
Figure 1-1 . Intel 5100 Chipset:
System Block Diagram
1-4
Chapter 1: Introduction
1-3 Server Chassis Features
The following is a general outline of the main features of the SC813MTQ-520C chassis. Details on the chassis can be found in Chapter 6.
System Power
When confi gured as a SuperServer 6015C-M3/6015C-MT, the SC813MTQ-520C chassis includes a single 520W power supply.
SAS/SATA Subsystem
For the 6015C-M3, the SC813MTQ-520C chassis was designed to support four SAS hard drives, which are hot-swappable units. For the 6015C-MT, the SC813MTQ-520C chass is was de sig ned to su ppo r t fou r SATA hard dr ives, w hic h are also hot-swappable units. Note: The operating system you use must have RAID support to enable the hot-swap capability of the SAS/SATA drives.
Control Panel
The SC813MTQ-520C's control panel provides important system monitoring and control information. LEDs indicate power on, network activity, hard disk drive activ­ity and system overheat conditions. The control panel also includes a main power button and a system reset button. The front of the SC813MTQ-520C also includes a COM port and two USB serial ports for easy access.
Rear I/O Panel
The SC813MTQ-520C is a 1U rackmount chassis. Its I/O panel provides a slot for one full-height, half-length PCI expansion card, one COM port (another is internal), two USB ports, a VGA port, PS/2 mouse and keyboard ports and two Gb Ethernet ports. See Chapter 6 for details.
Cooling System
The SC813MTQ-520C chassis has an innovative cooling design that features four high-performance 4-cm fans. Each of these fans plug into a chassis fan header on the serverboard. An air shroud channels the airfl ow generated by the fans to effi ciently cool the processor area of the system.
A fan speed control setting in BIOS allows fan speed to be determined by system temperature [the recommended setting is 3-pin (Server)].
1-5
SUPERSERVER 6015C-M3/6015C-MT User's Manual
1-4 Contacting Supermicro
Headquarters
Address: Super Micro Computer, Inc.
980 Rock Ave. San Jose, CA 95131 U.S.A.
Tel: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: marketing@supermicro.com (General Information)
support@supermicro.com (Technical Support)
Web Site: www.supermicro.com
Europe
Address: Super Micro Computer B.V.
Het Sterrenbeeld 28, 5215 ML 's-Hertogenbosch, The Netherlands
Tel: +31 (0) 73-6400390 Fax: +31 (0) 73-6416525 Email: sales@supermicro.nl (General Information)
support@supermicro.nl (Technical Support) rma@supermicro.nl (Customer Support)
Asia-Pacifi c
Address: Super Micro Computer, Inc.
4F, No. 232-1, Liancheng Rd. Chung-Ho 235, Taipei County Taiwan, R.O.C.
Tel: +886-(2) 8226-3990 Fax: +886-(2) 8226-3991 Web Site: www.supermicro.com.tw Technical Support: Email: support@supermicro.com.tw Tel: 886-2-8228-1366, ext.132 or 139
1-6
Chapter 2: Server Installation
Chapter 2
Server Installation
2-1 Overview
This chapter provides a quick setup checklist to get your SuperServer 6015C­M3/6015C-MT up and running. Following the steps in the order given should enable you to have the system operational within a minimal amount of time. This quick setup assumes that your 6015C-M3/6015C-MT system has come to you with the processor and memory preinstalled. If your system is not already fully integrated with a serverboard, processor, system memory etc., please turn to the chapter or section noted in each step for details on installing specifi c components.
2-2 Unpacking the System
You should inspect the box the SuperServer 6015C-M3/6015C-MT was shipped in and note if it was damaged in any way. If the server itself shows damage, you should fi le a damage claim with the carrier who delivered it.
Decide on a suitable location for the rack unit that will hold the SuperServer 6015C­M3/6015C-MT. It should be situated in a clean, dust-free area that is well ventilated. Avoid areas where heat, electrical noise and electromagnetic fi elds are generated. You will also need it placed near a grounded power outlet. Read the Rack and Server Precautions in the next section.
2-3 Preparing for Setup
The box the SuperServer 6015C-M3/6015C-MT was shipped in should include two sets of rail assemblies, six rail mounting brackets and the mounting screws you will need to install the system into the rack. Follow the steps in the order given to complete the installation process in a minimal amount of time. Please read this section in its entirety before you begin the installation procedure outlined in the sections that follow.
Choosing a Setup Location
Leave enough clearance in front of the rack to enable you to open the front door completely (~25 inches) and approximately 30 inches of clearance in the back of the rack to allow for suffi cient airfl ow and ease in servicing.
2-1
SUPERSERVER 6015C-M3/6015C-MT User's Manual
!
!
This product is for installation only in a Restricted Access Location (dedicated equipment rooms, service closets and the like).
This product is not suitable for use with visual display work place devices
acccording to §2 of the the German Ordinance for Work with Visual Display Units.
Warnings and Precautions!
Rack Precautions
Ensure that the leveling jacks on the bottom of the rack are fully extended to the fl oor with the full weight of the rack resting on them.
In single rack installation, stabilizers should be attached to the rack. In multiple
rack installations, the racks should be coupled together.
Always make sure the rack is stable before extending a component from the
rack.
You should extend only one component at a time - extending two or more si-
multaneously may cause the rack to become unstable.
Server Precautions
Review the electrical and general safety precautions in Chapter 4.
Determine the placement of each component in the rack before you install the rails.
Install the heaviest server components on the bottom of the rack fi rst, and then
work up.
Use a regulating uninterruptible power supply (UPS) to protect the server from
power surges, voltage spikes and to keep your system operating in case of a power failure.
Allow the hot plug SATA drives and power supply modules to cool before touch-
ing them.
Always keep the rack's front door and all panels and components on the servers
closed when not servicing to maintain proper cooling.
2-2
Chapter 2: Server Installation
Rack Mounting Considerations
Ambient Operating Temperature
If installed in a closed or multi-unit rack assembly, the ambient operating tempera­ture of the rack environment may be greater than the ambient temperature of the room. Therefore, consideration should be given to installing the equipment in an environment compatible with the manufacturer’s maximum rated ambient tempera­ture (Tmra).
Reduced Airfl ow
Equipment should be mounted into a rack so that the amount of airfl ow required for safe operation is not compromised.
Mechanical Loading
Equipment should be mounted into a rack so that a hazardous condition does not arise due to uneven mechanical loading.
Circuit Overloading
Consideration should be given to the connection of the equipment to the power supply circuitry and the effect that any possible overloading of circuits might have on overcurrent protection and power supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.
Reliable Ground
A reliable ground must be maintained at all times. To ensure this, the rack itself should be grounded. Particular attention should be given to power supply connec­tions other than the direct connections to the branch circuit (i.e. the use of power strips, etc.).for suffi cient airfl ow and ease in servicing.
2-3
SUPERSERVER 6015C-M3/6015C-MT User's Manual
2-4 Installing the System into a Rack
This section provides information on installing the SuperServer 6015C-M3/6015C­MT into a rack unit with the rack rails provided. If the server has already been mounted into a rack, you can skip ahead to Sections 2-5 and 2-6. There are a variety of rack units on the market, which may mean the assembly procedure will differ slightly. You should also refer to the installation instructions that came with the rack unit you are using.
Identifying the Sections of the Rack Rails
You may have received rack rail hardware with the SuperServer 6015C-M3/6015C­MT. (Two front inner rails should already be attached to the chassis.) This hard­ware consists of two rear inner rails that secure to the chassis, one on each side just behind the preinstalled front inner rails. Note that these two rails are left/right specifi c.
Installing the Rear Inner Rails
First, locate the right rear inner rail (the rail that will be used on the right side of the chassis when you face the front of the chassis). Align the two square holes on the rail against the hooks on the right side of the chassis. Securely attach the rail to the chassis with M4 fl at head screws. Repeat these steps to install the left rear inner rail to the left side of the chassis (see Figure 2-1). You will also need to attach the rail brackets when installing into a telco rack.
Locking Tabs: Both chassis rails have a locking tab, which serves two functions. The fi rst is to lock the server into place when installed and pushed fully into the rack, which is its normal position. Secondly, these tabs also lock the server in place when fully extended from the rack. This prevents the server from coming completely out of the rack when you pull it out for servicing.
2-4
Chapter 2: Server Installation
Figure 2-1. Installing Rear Inner Chassis Rails
Installing the Rack Rails
Determine where you want to place the SuperServer 6015C-M3/6015C-MT in the rack (see Rack and Server Precautions in Section 2-3). Position the chassis rail guides at the desired location in the rack, keeping the sliding rail guide facing the inside of the rack. Screw the assembly securely to the rack using the brackets provided. Attach the other assembly to the other side of the rack, making sure that both are at the exact same height and with the rail guides facing inward.
2-5
SUPERSERVER 6015C-M3/6015C-MT User's Manual
Installing the Server into the Rack
You should now have rails attached to both the chassis and the rack unit. The next step is to install the server into the rack. Do this by lining up the rear of the chassis rails with the front of the rack rails. Slide the chassis rails into the rack rails, keeping the pressure even on both sides (you may have to depress the locking tabs when inserting). See Figure 2-2.
When the server has been pushed completely into the rack, you should hear the locking tabs "click". Finish by inserting and tightening the thumbscrews that hold the front of the server to the rack.
Figure 2-2. Installing the Server into a Rack
(with optional front bezel shown)
2-6
Chapter 2: Server Installation
Installing the Server into a Telco Rack
To install the SuperServer 6015C-M3/6015C-MT into a Telco type rack, use two L­shaped brackets on either side of the chassis (four total). First, determine how far the server will extend out the front of the rack. Larger chassis should be positioned to balance the weight between front and back. If a bezel is included on your server, remove it. Then attach the two front brackets to each side of the chassis, then the two rear brackets positioned with just enough space to accommodate the width of the rack. Finish by sliding the chassis into the rack and tightening the brackets to the rack.
Figure 2-3. Installing the Server into a Telco Rack
(with optional front bezel shown)
2-7
SUPERSERVER 6015C-M3/6015C-MT User's Manual
2-5 Checking the Serverboard Setup
After you install the 6015C-M3/6015C-MT in the rack, you will need to open the unit to make sure the serverboard is properly installed and all the connections have been made.
Accessing the inside of the System
First, release the retention screws that secure the unit to the rack.Grasp the 1. two handles on either side and pull the unit straight out until it locks (you will hear a "click").
Depress the two buttons on the top of the chassis to release the top cover. 2. There is a large rectangular recess in the middle front of the top cover to help you push the cover away from you until it stops.
Lift the top cover from the chassis to gain full access to the inside of the 3. server.
Checking the Components and Setup
You may have one or more processors already installed into the system 1. board. Each processor should have its own heatsink attached. See Chapter 5 for instructions on processor installation.
Your 6015C-M3/6015C-MT server system may have come with system 2. memory already installed. Make sure all DIMMs are fully seated in their slots. For details on adding system memory, refer to Chapter 5.
If desired, you can install an add-on card to the system. See Chapter 5 for 3. details on installing a PCI add-on card.
Make sure all power and data cables are properly connected and not blocking 4. the airfl ow. Also make sure that no cables are positioned in front of the fans. See Chapter 5 for details on cable connections.
2-8
Chapter 2: Server Installation
Figure 2-4.
Accessing the Inside of the SuperServer 6015C-M3/6015C-MT
2-9
SUPERSERVER 6015C-M3/6015C-MT User's Manual
2-6 Checking the Chassis Setup
Next, you should check to make sure the peripheral drives and the SAS/SATA drives and SAS/SATA backplane have been properly installed and all essential connections have been made.
Checking the Drives
All drives can be accessed from the front of the server. For servicing the 1. DVD-ROM drive, you will need to remove the top chassis cover. The SAS/ SATA disk drives can be installed and removed from the front of the chassis without removing the top chassis cover.
Refer to Chapter 6 if you need to reinstall a DVD-ROM drive to the system.2.
Depending upon your system's confi guration, your system may have one 3. or more SAS/SATA drives already installed. If you need to install SAS/SATA drives, please refer to the appropriate section in Chapter 6.
Checking the Airfl ow
Airfl ow is provided by four high-performance 4-cm input fans. The system 1. component layout was carefully designed to promote suffi cient airfl ow through the small 1U rackmount space.
Also note that all power and data cables have been routed in such a way that 2. they do not block the airfl ow generated by the fans.
Providing Power
Plug the power cord from the power supply unit into a high-quality power strip 1. that offers protection from electrical noise and power surges.
It is recommended that you use an uninterruptible power supply (UPS).2.
Press the power button on the front of the chassis. 3.
2-10
Chapter 3: System Interface
Chapter 3
System Interface
3-1 Overview
There are several LEDs on the control panel as well as others on the SAS/SATA drive carriers to keep you constantly informed of the overall status of the system as well as the activity and health of specifi c components. There are also two but- tons on the chassis control panel and an on/off switch on the power supply. This chapter explains the meanings of all LED indicators and the appropriate response you may need to take.
3-2 Control Panel Buttons
There are two push-buttons located on the front of the chassis. These are (in order from left to right) a reset button and a power on/off button.
Reset
The reset button reboots the system.
Power
This is the main power button, which is used to apply or turn off the main system power. T urning off system power with this button removes the main power but keeps standby power supplied to the system.
3-1
SUPERSERVER 6015C-M3/6015C-MT User's Manual
3-3 Control Panel LEDs
The control panel located on the front of the SC813MTQ-520C chassis has fi ve LEDs. These LEDs provide you with critical information related to different parts of the system. This section explains what each LED indicates when illuminated and any corrective action you may need to take.
Overheat/Fan Fail
When this LED fl ashes, it indicates a fan failure. When on continuously it indicates an overheat condition, which may be caused by cables obstructing the airfl ow in the system or the ambient room temperature being too warm. Check the routing of the cables and make sure all fans are present and operating normally. You should also check to make sure that the chassis covers are installed. Finally, verify that the heatsinks are installed properly (see Chapter 5). This LED will remain fl ashing or on as long as the indicated condition exists.
2
NIC2
Indicates network activity on LAN2 when fl ashing .
1
NIC1
Indicates network activity on LAN1 when fl ashing.
HDD
Channel activity for all HDDs. This light indicates DVD-ROM and SAS/SATA drive activity on the 6015C-M3/6015C-MT when fl ashing.
3-2
Chapter 3: System Interface
Power
Indicates power is being supplied to the system's power supply units. This LED should normally be illuminated when the system is operating.
3- 4 Drive Carrie r LEDs
SAS Drives (6015C-M3)
Each SAS drive carrier has two LEDs:
Green:
When illuminated, the green LED on the front of the SAS drive carrier
indicates drive activity. A connection to the backplane enables this LED to blink on and off when that particular drive is being accessed.
Red:
The SES2 compliant backplane activates the red LED to indicate a drive
failure. If one of the SAS drives fail, you should be notifi ed by your system management software. Please refer to Chapter 6 for instructions on replacing failed SAS drives.
SATA Drives (6015C-MT)
Each SATA drive carrier has two LEDs.
Green:
When illuminated, the green LED on the front of the SATA drive carrier
indicates drive activity. A connection to the SATA backplane enables this LED to blink on and off when that particular drive is being accessed.
Red:
The red LED indicates two states. When blinking, it indicates the drive
is rebuilding. When solid, it indicates a drive failure. If a SATA drive fails, you should be notifi ed by your system management software. Please refer to Chapter 6 for instructions on replacing failed SATA drives.
3-3
SUPERSERVER 6015C-M3/6015C-MT User's Manual
Notes
3-4
Loading...