Supero SUPERSERVER 5016T-MTFB User Manual

SUPER
SUPERSERVER 5016T-MTFB
®
USER’S MANUAL
Revision 1.0b
The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccuracies that may be contained in this document, makes no commitment to update or to keep current the information in this manual, or to notify any person or organization of the updates. Please Note: For the most up-to-date version of this
manual, please see our web site at www.supermicro.com.
Super Micro Computer, Inc. ("Supermicro") reserves the right to make changes to the product described in this manual at any time and without notice. This product, including software and docu­mentation, is the property of Supermicro and/or its licensors, and is supplied only under a license. Any use or reproduction of this product is not allowed, except as expressly permitted by the terms of said license.
IN NO EVENT WILL SUPERMICRO BE LIABLE FOR DIRECT, INDIRECT , SPECIAL, INCIDENTAL, SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO USE THIS PRODUCT OR DOCUMENTATION, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. IN PARTICULAR, SUPERMICRO SHALL NOT HAVE LIABILITY FOR ANY HARDWARE, SOFTW ARE, OR DA TA STORED OR USED WITH THE PRODUCT, INCLUDING THE COSTS OF REPAIRING, REPLACING, INTEGRATING, INSTALLING OR RECOVERING SUCH HARDWARE, SOFTWARE, OR DATA.
Any disputes arising between manufacturer and customer shall be governed by the laws of Santa Clara County in the State of California, USA. The State of California, County of Santa Clara shall be the exclusive venue for the resolution of any such disputes. Super Micro's total liability for all claims will not exceed the price paid for the hardware product.
FCC Statement: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environ­ment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the manufacturer’s instruction manual, may cause harmful interference with radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case you will be required to correct the interference at your own expense.
California Best Management Practices Regulations for Perchlorate Materials: This Perchlorate warn­ing applies only to products containing CR (Manganese Dioxide) Lithium coin cells. “Perchlorate Material-special handling may apply. See www.dtsc.ca.gov/hazardouswaste/perchlorate”
WARNING: Handling of lead solder materials used in this product may expose you to lead, a chemical known to the State of California to cause birth defects and other repro­ductive harm.
Manual Revision 1.0b Release Date: May 10, 2010
Unless you request and receive written permission from Super Micro Computer, Inc., you may not copy any part of this document.
Information in this document is subject to change without notice. Other products and companies referred to herein are trademarks or registered trademarks of their respective companies or mark holders.
Copyright © 2010 by Super Micro Computer, Inc. All rights reserved.
Printed in the United States of America
Preface
About This Manual
This manual is written for professional system integrators and PC technicians. It provides information for the installation and use of the SuperServer 5016T-MTFB. Installation and maintainance should be performed by experienced technicians only.
The SuperServer 5016T-MTFB is a high-end single processor 1U rackmount server based on the SC813MTS-280C server chassis and the X8STi-F motherboard.
Manual Organization
Preface
Chapter 1: Introduction
The fi rst chapter provides a checklist of the main components included with the server system and describes the main features of the Super X8STi-F motherboard and the SC813MTS-280C chassis.
Chapter 2: Server Installation
This chapter describes the steps necessary to install the SuperServer 5016T-MTFB into a rack and check out the server confi guration prior to powering up the system. If your server was ordered without the processor and memory components, this chap­ter will refer you to the appropriate sections of the manual for their installation.
Chapter 3: System Interface
Refer to this chapter for details on the system interface, which includes the functions and information provided by the control panel on the chassis as well as other LEDs located throughout the system.
Chapter 4: System Safety
You should thoroughly familiarize yourself with this chapter for a general overview of safety precautions that should be followed when installing and servicing the SuperServer 5016T-MTFB.
iii
SUPERSERVER 5016T-MTFB User's Manual
Chapter 5: Advanced Motherboard Setup
Chapter 5 provides detailed information on the X8STi-F motherboard, including the locations and functions of connectors, headers and jumpers. Refer to this chapter when adding or removing processors or main memory and when reconfi guring the motherboard.
Chapter 6: Advanced Chassis Setup
Refer to Chapter 6 for detailed information on the SC813MTS-280C 1U rackmount server chassis. You should follow the procedures given in this chapter when install­ing, removing or reconfi guring SATA or peripheral drives and when replacing system power supply units and cooling fans.
Chapter 7: BIOS
The BIOS chapter includes an introduction to BIOS and provides detailed informa­tion on running the CMOS Setup Utility.
Appendix A: BIOS POST Messages
Appendix B: Installing Windows
Appendix C: System Specifi cations
iv
Notes
Preface
v
SUPERSERVER 5016T-MTFB User's Manual
Table of Contents
Chapter 1 Introduction
1-1 Overview .........................................................................................................1-1
1-2 Motherboard Features .....................................................................................1-2
Processor ........................................................................................................1-2
Memory ...........................................................................................................1-2
Onboard SATA .................................................................................................1-2
PCI Expansion Slots ....................................................................................... 1-2
Onboard Controllers/Ports ..............................................................................1-2
1-3 Server Chassis Features ................................................................................1-4
System Power ................................................................................................. 1-4
SATA Subsystem ............................................................................................. 1-4
Control Panel ..................................................................................................1-4
Rear I/O Panel ................................................................................................ 1-4
Cooling System ............................................................................................... 1-4
1-4 Contacting Supermicro ....................................................................................1-5
Chapter 2 Server Installation
2-1 Overview .........................................................................................................2-1
2-2 Unpacking the System .................................................................................... 2-1
2-3 Preparing for Setup .........................................................................................2-1
Choosing a Setup Location ............................................................................. 2-1
Rack Precautions ............................................................................................ 2-2
Server Precautions .......................................................................................... 2-2
Rack Mounting Considerations .......................................................................2-3
Ambient Operating Temperature ................................................................2-3
Reduced Airfl ow .........................................................................................2-3
Mechanical Loading ...................................................................................2-3
Circuit Overloading .....................................................................................2-3
Reliable Ground .........................................................................................2-3
2-4 Installing the System into a Rack ................................................................... 2-4
Identifying the Sections of the Rack Rails ...................................................... 2-4
Installing the Rear Inner Rails ........................................................................2-4
Installing the Rack Rails .................................................................................2-5
Installing the Server into the Rack .................................................................. 2-6
Installing the Server into a Telco Rack ...........................................................2-7
2-5 Checking the Motherboard Setup ................................................................... 2-8
2-6 Checking the Drive Bay Setup ........................................................................ 2-9
vi
Table of Contents
Chapter 3 System Interface
3-1 Overview .........................................................................................................3-1
3-2 Control Panel Buttons ..................................................................................... 3-1
Reset ...............................................................................................................3-1
Power ..............................................................................................................3-1
3-3 Control Panel LEDs ........................................................................................3-2
Overheat/Fan Fail ...........................................................................................3-2
NIC2 ................................................................................................................3-2
NIC1 ................................................................................................................3-2
HDD .................................................................................................................3-2
Power ..............................................................................................................3-3
3-4 Drive Carrier LEDs ..........................................................................................3-3
Chapter 4 System Safety
4-1 Electrical Safety Precautions .......................................................................... 4-1
4-2 General Safety Precautions ............................................................................4-2
4-3 ESD Precautions ............................................................................................. 4-3
4-4 Operating Precautions .................................................................................... 4-4
Chapter 5 Advanced Serverboard Setup
5-1 Handling the Serverboard ............................................................................... 5-1
Precautions .....................................................................................................5-1
Unpacking .......................................................................................................5-2
5-2 Serverboard Installation ..................................................................................5-2
5-3 Connecting Cables .......................................................................................... 5-3
Connecting Data Cables ................................................................................. 5-3
Connecting Power Cables ..............................................................................5-3
Connecting the Control Panel ......................................................................... 5-3
5-4 I/O Ports ..........................................................................................................5-4
5-5 Installing the Processor and Heatsink ............................................................ 5-5
Installing an LGA1366 Processor ................................................................... 5-5
Installing a Passive CPU Heatsink ................................................................. 5-7
Removing the Heatsink ................................................................................... 5-8
5-6 Installing Memory Modules ............................................................................. 5-9
Installing & Removing DIMMs ......................................................................... 5-9
Memory Support .......................................................................................5-10
5-7 Adding PCI Expansion Cards ........................................................................5-11
5-8 Serverboard Details ...................................................................................... 5-12
X8STi-F Quick Reference .............................................................................5-13
5-9 Connector Defi nitions ................................................................................... 5-14
vii
SUPERSERVER 5016T-MTFB User's Manual
Main ATX Power Supply Connector ......................................................... 5-14
Processor Power Connector .................................................................... 5-14
Power Button ............................................................................................5-14
Reset Button ............................................................................................. 5-14
Power Fail LED ....................................................................................... 5-14
Overheat/Fan Fail/UID LED ..................................................................... 5-15
NIC2 (JLAN2) LED ...................................................................................5-15
NIC1 (JLAN1) LED ...................................................................................5-15
HDD LED/UID Switch ............................................................................... 5-15
Power On LED ......................................................................................... 5-15
NMI Button ...............................................................................................5-16
Fan Headers ............................................................................................. 5-16
ATX PS/2 Keyboard and PS/2 Mouse Ports ............................................ 5-16
Serial Ports ...............................................................................................5-16
Chassis Intrusion ......................................................................................5-17
Wake-On-LAN ..........................................................................................5-17
External Speaker/Internal Buzzer.............................................................5-17
Overheat/Fan Fail LED ............................................................................5-17
LAN1/2 (Ethernet Ports) .......................................................................... 5-17
Universal Serial Bus (USB) ...................................................................... 5-18
SGPIO Headers .......................................................................................5-18
Power Supply SMBus Header..................................................................5-18
Onboard Power LED ................................................................................ 5-18
Power Supply Fail LED Header ............................................................... 5-19
Alarm Reset .............................................................................................. 5-19
I-Button .....................................................................................................5-19
Unit Identifi er Button ................................................................................. 5-19
5-10 Jumper Settings ............................................................................................5-20
Explanation of Jumpers ............................................................................ 5-20
CMOS Clear ............................................................................................. 5-20
VGA Enable/Disable ................................................................................. 5-20
LAN1/2 Enable/Disable ........................................................................... 5-21
Watch Dog Enable/Disable ...................................................................... 5-21
USB Wake-Up .........................................................................................5-21
SMBus to PCI Slots .................................................................................5-22
BMC Enable/Disable ................................................................................ 5-22
5-11 Onboard Indicators ........................................................................................5-22
LAN1/2 LEDs ............................................................................................ 5-22
viii
Table of Contents
Dedicated IPMI LAN LEDs ....................................................................... 5-23
Onboard Power LED (LE1) ......................................................................5-23
UID LED .................................................................................................. 5-23
BMC Heartbeat LED ................................................................................5-23
5-12 Floppy and SATA Ports ................................................................................. 5-24
Floppy Drive Connector ...........................................................................5-24
SATA Ports ............................................................................................... 5-24
5-13 Installing Software ......................................................................................... 5-25
Supero Doctor III ...........................................................................................5-26
Chapter 6 Advanced Chassis Setup
6-1 Static-Sensitive Devices ..................................................................................6-1
Precautions .....................................................................................................6-1
Unpacking .......................................................................................................6-1
6-2 Control Panel ..................................................................................................6-2
6-3 System Fans ...................................................................................................6-3
6-4 Drive Bay Installation/Removal .......................................................................6-3
Removing the Front Bezel .............................................................................. 6-3
SATA Drive Installation .................................................................................... 6-4
Accessing the Drive Bays ...............................................................................6-4
SATA Backplane .............................................................................................. 6-5
6-5 Power Supply .................................................................................................. 6-7
Power Supply Failure ......................................................................................6-7
Chapter 7 BIOS
7-1 Introduction ......................................................................................................7-1
Starting BIOS Setup Utility .............................................................................. 7-1
How To Change the Confi guration Data .........................................................7-1
Starting the Setup Utility ................................................................................. 7-2
7-2 Main Setup ...................................................................................................... 7-2
7-3 Advanced Setup Confi gurations......................................................................7-4
7-4 Security Settings ...........................................................................................7-23
7-5 Boot Confi guration ........................................................................................ 7-24
7-6 Exit Options ................................................................................................... 7-25
Appendix A POST Error Beep Codes Appendix B Installing Windows Appendix C System Specifi cations
ix
SUPERSERVER 5016T-MTFB User's Manual
Notes
x
Chapter 1: Introduction
Chapter 1
Introduction
1-1 Overview
The Supermicro SuperServer 5016T-MTFB is a high-end single processor, 1U rackmount server. The 5016T-MTFB is comprised of two main subsystems: the SC813MTS-280C chassis and the X8STi-F motherboard. Please refer to our web site for information on operating systems that have been certifi ed for use with the system.
In addition to the mainboard and chassis, various hardware components may have been included with the 5016T-MTFB, as listed below.
One CPU heatsink (SNK-P0036)
Four 4-cm fans (FAN-0061L4)
One air shroud (MCP-310-18009-0N)
One slim DVD-ROM drive (DVM-TEAC-DVD-SBT)
One internal USB cable for DVD-ROM drive (CBL-0341L)
One SATA to USB adapter for DVD-ROM drive (CDM-USATA-G)
SATA Accessories: One internal SATA backplane (BPN-SAS-815TQ) One set of SATA cables (CBL-0201L) One set of 65-cm SATA cables (CBL-0230L) One SGPIO cable (CBL-0157L) Four 3.5" SATA drive carriers [CSE-PT39(B)]
One PCI-E x16 slot riser card (CSE-RR1U-E16)
Rackmount hardware with screws (CSE-PT52)
One CD containing drivers and utilities
SuperServer 5016T-MTFB User's Manual Note: "B" indicates black.
1-1
SUPERSERVER 5016T-MTFB User's Manual
1-2 Motherboard Features
At the heart of the SuperServer 5016T-MTFB lies the X8STi-F, a single processor motherboard based upon Intel's X58 chipset. Below are the main features of the X8STi-F.
Processor
The X8STi-F supports single Intel® Xeon® 5500 Series processors below 100W. Please refer to the motherboard specifi cations pages on our web site for updates on supported processors.
Memory
The X8STi-F has six 240-pin DIMM slots that can support up to 24 GB of unbuffered ECC/non-ECC DDR2-1333/1066/800 SDRAM.
Onboard SATA
A SATA controller is built in to the ICH10R portion of the chipset to provide support for a six port, 3 Gb/sec Serial AT A subsystem. The SAT A drives are hot-swappable units.
PCI Expansion Slots
The X8STi-F has one PCI-E 2.0 x16 slot for use in the 5016T-MTFB server. This PCI-E slot may be populated with a riser card (included).
Onboard Controllers/Ports
An onboard IDE controller supports one fl oppy drive. Onboard I/O backpanel ports include one COM port, a VGA port, two USB ports, PS/2 mouse and keyboard ports and two Gigabit LAN (NIC) ports.
Other Features
Other onboard features that promote system health include voltage monitors, a chassis intrusion header, auto-switching voltage regulators, chassis and CPU overheat sensors, virus protection and BIOS rescue.
1-2
Chapter 1: Introduction
Figure 1-1. Intel X58/ICH10R Chipset: System Block Diagram
Note: This is a general block diagram. Please see Chapter 5 for details.
VRD 11.1
LAN1/LAN2
Intel 82574L
SATA x6
USB x8
Intersil
QPI: Up to 6.40 GT/s
PCI-E x2
3 Gb/s SATA
USB 2.0
W83627DHG
LPC I/O
Intel
LGA1366 CPU
Intel
X58
DMI
PCI-E x1
ICH10R
PCI-E_x8
PCI-E x16
PCI-E x1
PCI-32
SPI
DDR3-1333/1066/800
(Channel A, B, C)
PCI-E Gen1 x8 (in x4)
PCI-E Gen2 x16
Intel 82574L
Intel 82574L
PCI 32 Slot
BMC WPCM450
IPMI LAN
SPI EEPROM
RJ45
RJ45
Onboard
VGA
Kybd
Mouse
Floppy
COM1 COM2
1-3
SUPERSERVER 5016T-MTFB User's Manual
1-3 Server Chassis Features
The following is a general outline of the main features of the SC813MTS-280C chassis.
System Power
When confi gured as a SuperServer 5016T-MTFB, the SC813MTS-280C chassis includes a single 280W power supply.
SATA Subsystem
For the 5016T-MTFB, the SC813MTS -280 chas sis was desig ned to suppo rt four SATA hard drives, w hich a re hot- swappa ble unit s.
Note: The operating system you use must have RAID support to enable the hot-swap capability of the SATA drives (system-based RAID is not available for SATA).
Control Panel
The SC813MTS-280C's control panel provides important system monitoring and control information. LEDs indicate power on, network activity, hard disk drive activ­ity and system overheat conditions. The control panel also includes a main power button and a system reset button. The front of the SC813MTS-280C also includes a COM port and two USB serial ports for easy access.
Rear I/O Panel
The SC813MTS-280C is a 1U rackmount chassis. Its I/O panel provides one PCI motherboard expansion slot, one COM port (another is internal), two USB ports, a parallel (printer) port, PS/2 mouse and keyboard ports, a VGA port and two Gb Ethernet ports.
Cooling System
The SC813MTS-280C chassis has an innovative cooling design that features three 4-cm high-performance system cooling fans. Each of these fans plug into a chassis fan header on the motherboard. An air shroud channels the airfl ow generated by the fans to effi ciently cool the processor area of the system.
A fan speed control setting in BIOS allows fan speed to be determined by system temperature [the recommended setting is 3-pin (Server)].
1-4
Chapter 1: Introduction
1-4 Contacting Supermicro
Headquarters
Address: Super Micro Computer, Inc.
980 Rock Ave. San Jose, CA 95131 U.S.A.
Tel: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: marketing@supermicro.com (General Information)
support@supermicro.com (Technical Support)
Web Site: www.supermicro.com
Europe
Address: Super Micro Computer B.V.
Het Sterrenbeeld 28, 5215 ML 's-Hertogenbosch, The Netherlands
Tel: +31 (0) 73-6400390 Fax: +31 (0) 73-6416525 Email: sales@supermicro.nl (General Information)
support@supermicro.nl (Technical Support) rma@supermicro.nl (Customer Support)
Asia-Pacifi c
Address: Super Micro Computer, Inc.
4F, No. 232-1, Liancheng Rd. Chung-Ho 235, Taipei County Taiwan, R.O.C.
Tel: +886-(2) 8226-3990 Fax: +886-(2) 8226-3991 Web Site: www.supermicro.com.tw Technical Support: Email: support@supermicro.com.tw Tel: 886-2-8228-1366, ext.132 or 139
1-5
SUPERSERVER 5016T-MTFB User's Manual
Notes
1-6
Chapter 2: Server Installation
Chapter 2
Server Installation
2-1 Overview
This chapter provides a quick setup checklist to get your SuperServer 5016T-MTFB up and running. Following the steps in the order given should enable you to have the system operational within a minimal amount of time. This quick setup assumes that your 5016T-MTFB system has come to you with the processor and memory preinstalled. If your system is not already fully integrated with a motherboard, pro­cessor, system memory etc., please turn to the chapter or section noted in each step for details on installing specifi c components.
2-2 Unpacking the System
You should inspect the box the SuperServer 5016T-MTFB was shipped in and note if it was damaged in any way. If the server itself shows damage, you should fi le a damage claim with the carrier who delivered it.
Decide on a suitable location for the rack unit that will hold the SuperServer 5016T­MTFB. It should be situated in a clean, dust-free area that is well ventilated. Avoid areas where heat, electrical noise and electromagnetic fi elds are generated. You will also need it placed near a grounded power outlet. Read the Rack and Server Precautions in the next section.
2-3 Preparing for Setup
The box the SuperServer 5016T-MTFB was shipped in should include two sets of rail assemblies, six rail mounting brackets and the mounting screws you will need to install the system into the rack. Follow the steps in the order given to complete the installation process in a minimal amount of time. Please read this section in its entirety before you begin the installation procedure outlined in the sections that follow.
Choosing a Setup Location
Leave enough clearance in front of the rack to enable you to open the front door completely (~25 inches) and approximately 30 inches of clearance in the back of the rack to allow for suffi cient airfl ow and ease in servicing.This product is for
2-1
SUPERSERVER 5016T-MTFB User's Manual
!
!
installation only in a Restricted Access Location (dedicated equipment rooms, service closets and the like).
This product is not suitable for use with visual display work place devices
acccording to §2 of the the German Ordinance for Work with Visual Display Units.
Warnings and Precautions!
Rack Precautions
Ensure that the leveling jacks on the bottom of the rack are fully extended to the fl oor with the full weight of the rack resting on them.
In single rack installation, stabilizers should be attached to the rack. In multiple
rack installations, the racks should be coupled together.
Always make sure the rack is stable before extending a component from the
rack.
You should extend only one component at a time - extending two or more si-
multaneously may cause the rack to become unstable.
Server Precautions
Review the electrical and general safety precautions in Chapter 4.
Determine the placement of each component in the rack before you install the rails.
Install the heaviest server components on the bottom of the rack fi rst, and then
work up.
Use a regulating uninterruptible power supply (UPS) to protect the server from
power surges, voltage spikes and to keep your system operating in case of a power failure.
Allow the hot plug SATA drives and power supply modules to cool before touch-
ing them.
Always keep the rack's front door and all panels and components on the servers
closed when not servicing to maintain proper cooling.
2-2
Chapter 2: Server Installation
Rack Mounting Considerations
Ambient Operating Temperature
If installed in a closed or multi-unit rack assembly, the ambient operating tempera­ture of the rack environment may be greater than the ambient temperature of the room. Therefore, consideration should be given to installing the equipment in an environment compatible with the manufacturer’s maximum rated ambient tempera­ture (Tmra).
Reduced Airfl ow
Equipment should be mounted into a rack so that the amount of airfl ow required for safe operation is not compromised.
Mechanical Loading
Equipment should be mounted into a rack so that a hazardous condition does not arise due to uneven mechanical loading.
Circuit Overloading
Consideration should be given to the connection of the equipment to the power supply circuitry and the effect that any possible overloading of circuits might have on overcurrent protection and power supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.
Reliable Ground
A reliable ground must be maintained at all times. To ensure this, the rack itself should be grounded. Particular attention should be given to power supply connec­tions other than the direct connections to the branch circuit (i.e. the use of power strips, etc.).
2-3
SUPERSERVER 5016T-MTFB User's Manual
2-4 Installing the System into a Rack
This section provides information on installing the SuperServer 5016T-MTFB into a rack unit with the rack rails provided. If the server has already been mounted into a rack, you can skip ahead to Sections 2-5 and 2-6.
There are a variety of rack units on the market, which may mean the assembly procedure will differ slightly. You should also refer to the installation instructions that came with the rack unit you are using.
Identifying the Sections of the Rack Rails
You may have received rack rail hardware with the SuperServer 5016T -MTFB. (Two front inner rails should already be attached to the chassis.) This hardware consists of two rear inner rails that secure to the chassis, one on each side just behind the preinstalled front inner rails. Note that these two rails are left/right specifi c.
Installing the Rear Inner Rails
First, locate the right rear inner rail (the rail that will be used on the right side of the chassis when you face the front of the chassis). Align the two square holes on the rail against the hooks on the right side of the chassis. Securely attach the rail to the chassis with M4 fl at head screws. Repeat these steps to install the left rear inner rail to the left side of the chassis (see Figure 2-1). You will also need to attach the rail brackets when installing into a telco rack.
Locking Tabs: Both chassis rails have a locking tab, which serves two functions. The fi rst is to lock the server into place when installed and pushed fully into the rack, which is its normal position. Secondly, these tabs also lock the server in place when fully extended from the rack. This prevents the server from coming completely out of the rack when you pull it out for servicing.
2-4
Chapter 2: Server Installation
Figure 2-1. Installing Rear Inner Chassis Rails
Installing the Rack Rails
Determine where you want to place the SuperServer 5016T-MTFB in the rack (see Rack and Server Precautions in Section 2-3). Position the chassis rail guides at the desired location in the rack, keeping the sliding rail guide facing the inside of the rack. Screw the assembly securely to the rack using the brackets provided. Attach the other assembly to the other side of the rack, making sure that both are at the exact same height and with the rail guides facing inward.
2-5
SUPERSERVER 5016T-MTFB User's Manual
Installing the Server into the Rack
You should now have rails attached to both the chassis and the rack unit. The next step is to install the server into the rack. Do this by lining up the rear of the chassis rails with the front of the rack rails. Slide the chassis rails into the rack rails, keeping the pressure even on both sides (you may have to depress the locking tabs when inserting). See Figure 2-2.
When the server has been pushed completely into the rack, you should hear the locking tabs "click".
Figure 2-2. Installing the Server into a Rack
(with optional front bezel shown)
2-6
Chapter 2: Server Installation
Installing the Server into a Telco Rack
To install the SuperServer 5016T-MTFB into a Telco type rack, use two L-shaped brackets on either side of the chassis (four total). First, determine how far the server will extend out the front of the rack. Larger chassis should be positioned to balance the weight between front and back. If a bezel is included on your server, remove it. Then attach the two front brackets to each side of the chassis, then the two rear brackets positioned with just enough space to accommodate the width of the rack. Finish by sliding the chassis into the rack and tightening the brackets to the rack.
Figure 2-3. Installing the Server into a Telco Rack
(with optional front bezel shown)
2-7
SUPERSERVER 5016T-MTFB User's Manual
2-5 Checking the Motherboard Setup
After you install the 5016T-MTFB in the rack, you will need to open the unit to make sure the motherboard is properly installed and all the connections have been made.
Accessing the Inside of the System
Grasp the two handles on either side and pull the unit straight out until it 1. locks (you will hear a "click").
Depress the two buttons on the top of the chassis to release the top cover. 2. There is a large rectangular recess in the middle front of the top cover to help you push the cover away from you until it stops.
Lift the top cover from the chassis to gain full access to the inside of the 3. server. See Figure 2-4.
Checking the Components
You may have the processor already installed into the system board. The 1. processor should have its own heatsink attached. See Chapter 5 for instruc­tions on processor installation.
Your 5016T-MTFB server system may have come with system memory al-2. ready installed. Make sure all DIMMs are fully seated in their slots. For details on adding system memory, refer to Chapter 5.
If desired, you can install an add-on card to the system. See Chapter 5 for 3. details on installing a PCI add-on card.
Make sure all power and data cables are properly connected and not blocking 4. the airfl ow. See Chapter 5 for details on cable connections.
2-8
Chapter 2: Server Installation
Figure 2-4.
Accessing the Inside of the SuperServer 5016T-MTFB
2-6 Checking the Drive Bay Setup
Next, you should check to make sure the peripheral drives and the SATA drives and their backplane have been properly installed and all essential connections have been made.
Checking the Drives
All drives can be accessed from the front of the server. For servicing the 1. CD-ROM drive, you will need to remove the top chassis cover. The SATA disk drives can be installed and removed from the front of the chassis without removing the top chassis cover.
Refer to Chapter 6 if you need to reinstall a DVD-ROM drive to the system.2.
Depending upon your system's confi guration, your system may have one or 3. more drives already installed. If you need to install drives, please refer to the appropriate section in Chapter 6.
Checking the Airfl ow
Airfl ow is provided by four high-performance 4-cm input fans. The system 1. component layout was carefully designed to promote suffi cient airfl ow through the small 1U rackmount space.
2-9
SUPERSERVER 5016T-MTFB User's Manual
Also note that all power and data cables have been routed in such a way that 2. they do not block the airfl ow generated by the fans.
Providing Power
Plug the power cord from the power supply unit into a high-quality power strip 1. that offers protection from electrical noise and power surges. It is recommend­ed that you use an uninterruptible power supply (UPS).
Depress the power button on the front of the chassis to power up the system. 2.
2-10
Chapter 3: System Interface
Chapter 3
System Interface
3-1 Overview
There are several LEDs on the control panel as well as others on the SATA drive carriers to keep you constantly informed of the overall status of the system as well as the activity and health of specifi c components. There are also two buttons on the chassis control panel and an on/off switch on the power supply. This chapter explains the meanings of all LED indicators and the appropriate response you may need to take.
3-2 Control Panel Buttons
There are two push-buttons located on the front of the chassis: a reset button and a power on/off button.
Reset
The reset button reboots the system.
Power
This is the main power button, which is used to apply or turn off the main system power. T urning off system power with this button removes the main power but keeps standby power supplied to the system.
3-1
SUPERSERVER 5016T-MTFB User's Manual
3-3 Control Panel LEDs
The control panel located on the front of the SC813MTS-280C chassis has fi ve LEDs. These LEDs provide you with critical information related to different parts of the system. This section explains what each LED indicates when illuminated and any corrective action you may need to take.
Overheat/Fan Fail
When this LED fl ashes, it indicates a fan failure. When on continuously it indicates an overheat condition, which may be caused by cables obstructing the airfl ow in the system or the ambient room temperature being too warm. Check the routing of the cables and make sure all fans are present and operating normally. You should also check to make sure that the chassis covers are installed. Finally, verify that the heatsinks are installed properly (see Chapter 5). This LED will remain fl ashing or on as long as the indicated condition exists.
2
NIC2
Indicates network activity on GLAN2 when fl ashing.
1
NIC1
Indicates network activity on GLAN1 when fl ashing.
HDD
Channel activity for all HDDs. This light indicates SATA drive activity on the 5016T­MTFB when fl ashing.
3-2
Chapter 3: System Interface
Power
Indicates power is being supplied to the system's power supply units. This LED should normally be illuminated when the system is operating.
3-4 Drive Carrier LEDs
Each drive carrier has two LEDs.
Green:
When illuminated, the green LED on the front of the drive carrier in-
dicates drive activity. A connection to the SATA backplane enables this LED to blink on and off when that particular drive is being accessed.
Red:
The red LED indicates two states. When blinking, it indicates the drive
is rebuilding. When solid, it indicates a drive failure. If a drive fails, you should be notifi ed by your system management software. Please refer to Chapter 6 for instructions on replacing failed drives.
3-3
SUPERSERVER 5016T-MTFB User's Manual
Notes
3-4
Loading...