Supero SUPERSERVER 2027TR-D70RF+ User Manual

®
SUPER
SUPERSERVER
Revision 1.0
SUPERSERVER 2027TR-D70RF+
manual, please see our web site at
www.supermicro.com.
Super Micro Computer, Inc. ("Supermicro") reserves the right to make changes to the product described in this manual at any time and without notice. This product, including software and documentation, is the property of Supermicro and/or its licensors, and is supplied only under a license. Any use or reproduction of this product is not allowed, except as expressly permitted by the terms of said license.
IN NO EVENT WILL SUPERMICRO BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL, SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO USE THIS PRODUCT OR DOCUMENTATION, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. IN PARTICULAR, SUPERMICRO SHALL NOT HAVE LIABILITY FOR ANY HARDWARE, SOFTW ARE, OR DA TA ST ORED OR USED WITH THE PRODUCT, INCLUDING THE COSTS OF REPAIRING, REPLACING, INTEGRATING, INSTALLING OR RECOVERING SUCH HARDWARE, SOFTWARE, OR DATA.
Any disputes arising between manufacturer and customer shall be governed by the laws of Santa Clara County in the State of California, USA. The State of California, County of Santa Clara shall be the exclusive venue for the resolution of any such disputes. Super Micro's total liability for all claims will not exceed the price paid for the hardware product.
FCC Statement: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the manufacturer’s instruction manual, may cause harmful interference with radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case you will be required to correct the interference at your own expense.
California Best Management Practices Regulations for Perchlorate Materials: This Perchlorate warning applies only to products containing CR (Manganese Dioxide) Lithium coin cells. “Perchlorate Material-special handling may apply. See
www.dtsc.ca.gov/hazardouswaste/perchlorate
WARNING: Handling of lead solder materials used in this product may expose you to lead, a chemical known to the State of California to cause birth defects and other reproductive harm.
Manual Revision 1.0 Release Date: December 18, 2012
Unless you request and receive written permission from Super Micro Computer, Inc., you may not copy any part of this document.
Information in this document is subject to change without notice. Other products and companies referred to herein are trademarks or registered trademarks of their respective companies or mark holders.
Copyright © 2012 by Super Micro Computer, Inc. All rights reserved.
Printed in the United States of America
iii
Preface
Preface
About This Manual
This manual is written for professional system integrators and PC technicians. It provides information for the installation and use of the SuperServer 2027TR-D70RF+. Installation and maintainance should be performed by experienced technicians only .
The SuperServer 2027TR-D70RF+ are all high-end servers based on the SC217HD-R1K28MB 2U rackmount chassis and the dual processor X9DRT-HF+ serverboard.
Manual Organization
Chapter 1: Introduction
The fi rst chapter provides a checklist of the main components included with the server system and describes the main features of the X9DRT-HF+ serverboard and the SC217HD-R1K28MB chassis.
Chapter 2: Server Installation
This chapter describes the steps necessary to install the SuperServer 2027TR-D70RF+ into a rack and check out the server confi guration prior to powering up the system. If your server was ordered without processor and memory components, this chapter will refer you to the appropriate sections of the manual for their installation.
Chapter 3: System Interface
Refer here for details on the system interface, which includes the functions and information provided by the control panel on the chassis as well as other LEDs located throughout the system.
Chapter 4: System Safety
You should thoroughly familiarize yourself with this chapter for a general overview of safety precautions that should be followed when installing and servicing the SuperServer 2027TR-D70RF+.
Chapter 5: Advanced Serverboard Setup
Chapter 5 provides detailed information on the X9DRT-HF+ serverboard, including the locations and functions of connections, headers and jumpers. Refer to this chapter when adding or removing processors or main memory and when reconfi guring the serverboard.
SUPERSERVER 2027TR-D70RF+ SUPERSERVER
iv
Chapter 6: Advanced Chassis Setup
Refer to Chapter 6 for detailed information on the SC217HD-R1K28MB server chassis. You should follow the procedures given in this chapter when installing, removing or reconfi guring SATA or peripheral drives and when replacing system power supply units and cooling fans.
Chapter 7: BIOS
The BIOS chapter includes an introduction to BIOS and provides detailed information on running the CMOS Setup Utility.
Appendix A: BIOS Error Beep Codes Appendix B: System Specifi cations
v
SUPERSERVER 2027TR-D70RF+ SUPERSERVER
Notes
vi
Table of Contents
Chapter 1 Introduction
1-1 Overview .........................................................................................................1-1
1-2 Serverboard Features .....................................................................................1-2
Processors ......................................................................................................1-2
Memory ...........................................................................................................1-2
SAS/SATA........................................................................................................ 1-2
PCI Expansion Slots .......................................................................................1-2
Onboard Controllers/Ports .............................................................................. 1-3
Graphics Controller .........................................................................................1-3
Other Features ................................................................................................ 1-3
1-3 Server Chassis Features ................................................................................ 1-3
System Power ................................................................................................. 1-3
SAS/SATA Subsystem .....................................................................................1-3
Front Control Panel ......................................................................................... 1-4
I/O Ports ..........................................................................................................1-4
Cooling System ............................................................................................... 1-4
Air Shrouds ..................................................................................................... 1-4
Mounting Rails ................................................................................................ 1-4
1-4 Advanced Power Management (for -F Models Only) .....................................1-4
Intel® Intelligent Power Node Manager (NM) .................................................1-4
Manageability Engine (ME) ............................................................................. 1-5
1-5 Contacting Supermicro ....................................................................................1-7
1-6 2U Twin: System Notes ...................................................................................1-8
Nodes ..............................................................................................................1-8
System Power ................................................................................................. 1-8
SAS/SATA Backplane/Drives .......................................................................... 1-8
Chapter 2 Server Installation
2-1 Overview .........................................................................................................2-1
2-2 Unpacking the System .................................................................................... 2-1
2-3 Preparing for Setup ......................................................................................... 2-1
Choosing a Setup Location .............................................................................2-2
2-4 Warnings and Precautions! ............................................................................. 2-2
Rack Precautions ............................................................................................ 2-2
Server Precautions ..........................................................................................2-2
Rack Mounting Considerations ....................................................................... 2-3
SUPERSERVER 2027TR-D70RF+ SUPERSERVER
vii
Ambient Operating Temperature ................................................................ 2-3
Reduced Airfl ow ......................................................................................... 2-3
Mechanical Loading ................................................................................... 2-3
Circuit Overloading ..................................................................................... 2-3
Reliable Ground ......................................................................................... 2-3
2-5 Installing the System into a Rack ...................................................................2-4
Separating the Sections of the Rack Rails ..................................................... 2-4
Locking Tabs ...................................................................................................2-5
Releasing the Inner Rail ................................................................................. 2-5
Installing The Inner Rails on the Chassis ....................................................... 2-6
Installing the Outer Rails on the Rack ............................................................ 2-7
Standard Chassis Installation ......................................................................... 2-8
Optional Quick Installation Method ................................................................. 2-9
2-6 Checking the Serverboard Setup ....................................................................2-9
Accessing the inside of the System ................................................................2-9
2-7 Checking the Drive Bay Setup .......................................................................2-11
Chapter 3 System Interface
3-1 Overview .........................................................................................................3-1
3-2 Control Panel Buttons ..................................................................................... 3-2
3-3 Control Panel LEDs ........................................................................................ 3-2
3-4 Drive Carrier LEDs .......................................................................................... 3-3
Chapter 4 Standardized Warning Statements for AC Systems
4-1 About Standardized Warning Statements ....................................................... 4-1
Warning Defi nition ...........................................................................................4-1
Installation Instructions ....................................................................................4-4
Circuit Breaker ................................................................................................ 4-5
Power Disconnection Warning ........................................................................ 4-6
Equipment Installation ..................................................................................... 4-8
Restricted Area ................................................................................................ 4-9
Battery Handling ............................................................................................4-10
Redundant Power Supplies .......................................................................... 4-12
Backplane Voltage ........................................................................................4-13
Comply with Local and National Electrical Codes ........................................ 4-14
Product Disposal ........................................................................................... 4-15
Hot Swap Fan Warning .................................................................................4-16
Power Cable and AC Adapter ......................................................................4-18
Table of Contents
viii
Chapter 5 Advanced Motherboard Setup
5-1 Handling the Motherboard .............................................................................. 5-1
Precautions .....................................................................................................5-1
Unpacking .......................................................................................................5-1
5-2 Rear I/O Ports ................................................................................................. 5-2
5-3 Processor and Heatsink Installation................................................................5-3
Installing a Passive CPU Heatsink .................................................................5-7
Removing the Passive Heatsink ..................................................................... 5-7
5-4 Installing Memory ............................................................................................5-8
Memory Support ..............................................................................................5-8
Maximum Memory ...........................................................................................5-8
DIMM Module Population Confi guration .................................................. 5-10
5-5 Adding PCI Expansion Cards .......................................................................5-12
5-6 Motherboard Details ...................................................................................... 5-13
5-7 Connector Defi nitions ....................................................................................5-16
5-8 Jumper Settings ............................................................................................ 5-19
Explanation of Jumpers ................................................................................ 5-19
5-9 Onboard Indicators ........................................................................................5-21
5-10 PCI-Express and Serial ATA Connections .................................................... 5-23
5-11 Installing Drivers ............................................................................................5-24
Supero Doctor III ........................................................................................... 5-25
5-12 Onboard Battery ............................................................................................5-27
Chapter 6 Advanced Chassis Setup
6-1 Static-Sensitive Devices ..................................................................................6-1
Precautions .....................................................................................................6-1
Unpacking .......................................................................................................6-1
6-2 Control Panel ..................................................................................................6-2
Accessing the inside of the System ................................................................6-3
6-4 Installing the Air Shrouds ................................................................................ 6-4
Air Shrouds ..................................................................................................... 6-4
6-5 Checking the Airfl ow ....................................................................................... 6-5
6-6 System Fans ................................................................................................... 6-5
Optional Fan Confi gurations ...........................................................................6-5
6-7 Removing and Installing the Backplane ..........................................................6-8
Removing the Backplane ................................................................................ 6-8
Installing the Backplane ................................................................................ 6-10
6-8 Installing the Motherboard .............................................................................6-11
I/O Shield .......................................................................................................6-11
SUPERSERVER 2027TR-D70RF+ SUPERSERVER
Compatible Motherboards ..............................................................................6-11
Permanent and Optional Standoffs ................................................................6-11
6-9 Node Installation/Removal ............................................................................6-13
6-10 Installing and Replacing the Adapter Card ................................................... 6-15
PCI Slot Setup .............................................................................................. 6-16
6-11 Installing and Removing Hard Drives ...........................................................6-18
6-12 Power Supply ................................................................................................ 6-22
Power Supply Replacement ..........................................................................6-22
Chapter 7 BIOS
7-1 Introduction ......................................................................................................7-1
Starting BIOS Setup Utility ..............................................................................7-1
How To Change the Confi guration Data ......................................................... 7-1
Starting the Setup Utility .................................................................................7-2
7-2 Main Setup ...................................................................................................... 7-2
7-3 Advanced Settings Menu ................................................................................ 7-3
7-4 Event Logs .................................................................................................... 7-26
7-5 IPMI ............................................................................................................... 7-28
7-6 Boot ...............................................................................................................7-30
7-7 Security .........................................................................................................7-31
7-8 Save & Exit ................................................................................................... 7-32
Appendix A BIOS Error Beep Codes Appendix B System Specifi cations
ix
Table of Contents
x
Notes
SUPERSERVER 2027TR-D70RF+ SUPERSERVER
Chapter 1
Introduction
1-1 Overview
The SuperServer 2027TR-D70RF+ is a high-end server comprised of two main subsystems: the SC217HD-R1K28MB 2U server chassis and the X9DRT-HF+ dual processor serverboard in two hot-swap nodes. Please refer to our web site for information on operating systems that have been certifi ed for use with the system (www.supermicro.com).
In addition to the serverboard and chassis, various hardware components have been included with the 2027TR-D70RF+ server, as listed below:
Four (4) 2U Passive CPU heat sinks w/narrow ILM (SNK-P0048PS)
Two (2) Plastic air shrouds (MCP-310-82718-0B)
Four (4) 80x80x38mm cooling fans (FAN-0129L4)
SATA/SAS Backplane
One (1) SAS Backplane for 12 2.5" HDD (BPN-SAS-217HD) Twenty-four (24) hot-swap 2.5" HDD trays (MCP-220-00047-0B) Two (2) SAS2 LSI2008 HD adapter cards (BPN-ADP-E16-L)
One (1) Rails set (MCP-290-00053-0N)
Note: a complete list of safety warnings is provided on the Supermicro web site at
http://www.supermicro.com/about/policies/safety_information.cfm
Chapter 1: Introduction
1-1
1-2
SUPERSERVER 2027TR-D70RF+ USER'S MANUAL
1-2 Serverboard Features
At the heart of the 2027TR-D70RF+ server lies the X9DRT-HF+, a dual processor serverboard based on the Intel® C602 chipset and designed to provide maximum performance. Two of these serverboards can be mounted in the SC217HD-R1K28MB chassis.
The sections below cover the main features of the X9DRT-HF+ serverboard (see Figure 1-1 for a block diagram of the chipset).
Processors
The X9DRT-HF+ supports single or dual Intel Xeon® E5-2600 series processors (Socket R LGA 2011). Please refer to the serverboard description pages on our web site for a complete listing of supported processors (www.supermicro.com).
Memory
The X9DRT-HF+ has sixteen (16) DIMM slots supporting up to 512 GB of DDR3-1600/1333/1066/800 MHz speed registered ECC SDRAM in up to 512 MB, 1 GB, 2 GB, 4 GB, 8 GB, 16 GB or 32 GB sizes at 1.35V or 1.5V voltages. See Chapter 5 for details.
Note: Check the Supermicro website (www.supermicro.com) for the latest memory support information.
SAS/SATA
An LSI® SAS2008 SAS2 controller is integrated into the installed BPN-ADP-E16-L adapter cards to provide a twelve port 6 Gb/s SAS2 (Serial Attached SCSI) /SATA3 subsystem for each node. The system has either RAID 0, 1 and 10 support for the SuperServer 2027TR-D70RF+ server. The SAS/SATA drives are hot-swappable units.
Note: The operating system you use must have RAID support to enable the hotswap c apabil ity an d RA ID fu nctio n of the SA S/SATA dri ves.
PCI Expansion Slots
The SuperServer 2027TR-D70RF+ has for each node one (1) available PCI-E 3.0 x8 Slot for SMC-Proprietary Micro LP Card (CPU1 Slot2) that can be used.
1-3
Chapter 1: Introduction
Onboard Controllers/Ports
The color-coded I/O ports include a VGA (monitor) port, two USB 2.0 ports (an additional internal USB header and one Type A USB connector are included on the serverboard), an IPMI 2.0 dedicated LAN port and two Ethernet ports.
Note: For IPMI Confi guration Instructions, please refer to the Embedded BMC Confi guration User's Guide available @
http://www.supermicro.com/support/
manuals/ for IPMI 2.0 system.
Graphics Controller
The X9DRT-HF+ features an integrated Matrox® G200eW Video Controller.
Other Features
Other onboard features that promote system health include onboard voltage monitors, a chassis intrusion header, auto-switching voltage regulators, chassis and CPU overheat sensors, virus protection, node manager software and BIOS rescue.
1-3 Server Chassis Features
The following is a general outline of the main features of the SC217HD server chassis.
System Power
Each SC217HD chassis model includes a high-effi ciency 80-plus Platinum certifi ed power supply, rated at 1280 Watts plus one redundant backup power supply. In the unlikely event your power supply fails, replacement is simple and can be accomplished without tools.
SAS/SATA Subsystem
The SC217HD supports up to twenty-four (24) 2.5" hot-swap SAS/SATA drives in trays (12 for each node). These drives are hot-swappable units and are connected to a backplane that provides power and control.
Note: The operating system you use must have RAID support to enable the hot­swap capability of the drives.
1-4
SUPERSERVER 2027TR-D70RF+ USER'S MANUAL
Front Control Panel
SC217HD-R1K28MB chassis includes two front panels on the handles of the chassis which control each of the systems. Each control panel on the SuperServer 2027TR-D70RF+ provides you with system monitoring and control for one server node. LEDs indicate system power, HDD activity, network activity, system overheat and power supply failure. A main power button and a system reset button are also included.
I/O Ports
The SC217HD is an propriertary form factor chassis designed to be used in a 2U rackmount confi guration. The SC217HD chassis provides a low-profi le add-on card slot, a COM port, a VGA port, two USB 2.0 ports, one IPMI Ethernet port and two Ethernet ports per node.
Cooling System
The SC217HD chassis accepts four system fans. System fans for the SC217HD chassis are powered from the motherboards or the HDD backplane. On SC217HD model chassis, the two fans on each side are controlled by two motherboards, so that when one of the motherboard nodes is removed, the second motherboard will continue to control both fans.
Air Shrouds
The SC217HD chassis includes two plastic air shrouds that direct the airfl ow where cooling is needed on each serverboard. Always use the air shroud included with your chassis on each serverboard.
Mounting Rails
The SC217HD includes a set of quick-release rails, and can be placed in a rack for secure storage and use. To setup your rack, follow the step-by-step instructions included in this manual.
1-4 Advanced Power Management (for -F Models Only)
Intel® Intelligent Power Node Manager (NM)
The Intel® Intelligent Power Node Manager (IPNM) provides your system with real-time thermal control and power management for maximum energy effi ciency. Although IPNM Specifi cation Version 1.5 is supported by the BMC (Baseboard
1-5
Chapter 1: Introduction
Management Controller), your system must also have IPNM-compatible Manageability Engine (ME) fi rmware installed to use this feature.
Manageability Engine (ME)
The Manageability Engine, which is an ARC controller embedded in the IOH (I/O Hub), provides Server Platform Services (SPS) to your system. The services provided by SPS are different from those proveded by the ME on client platforms.
1-6
SUPERSERVER 2027TR-D70RF+ USER'S MANUAL
Figure 1-1. Intel C602 Chipset:
System Block Diagram
Note: This is a general block diagram and may not exactly repre-
sent the features on your motherboard. See the previous pages for
the actual specifi cations of your motherboard. This block diagram is
intended for your reference only.
#2
#2
#2
#2
#2
#2
#2
#2
PROCESSOR
SANDYBRIDGE
PROCESSOR
SANDYBRIDGE
QPI
DDR3 DIMM
DDR3 DIMM
DDR3 DIMM
DDR3 DIMM
#1
G
SSB
PATSBURG
PEG0
DMI
PEG1_1
PEG1_8
PCI-32bit
USB
LAN I350 2 ports
AT25321
LPC
CPU FRONT
FAN Side
CPU REAR (I/O Side)
USB
REAR
HDR 2X5
0,1
TPM Header
USB Type-A
2,3
U7C1
U6H1
H
F
E
Socket 0
Socket 1
#1
P0
P0
P1
P1
PE3 PE2 PE1 DMI
PE3 PE2 PE1 DMI
Gen3 x8
x4
VGA BMC
WPCM450
DDR2
PHY1
LAN
RTL8201F
SPI
SATA
Gen2
PCI-E x8 MicroLP SLOT
x4
RJ45 RJ45
Gen3
x8
Gen3
x8
PCI-E x8 in x4 SLOT
x8
x1
x8(0..7)
HOTSWAP INTERFACE
SATA2 #5
SATA2 #4
SATA2 #3
SATA2 #2
SATA3 #1
SATA3 #0
PORT6
PORT5
PORT4
PORT3
PORT2
PORT1
6/3/1.5
QPI
VGA CONN
DDR3 DIMM
DDR3 DIMM
#1
C
#1
D
DDR3 DIMM
DDR3 DIMM
A
B
#1
#1
#1
#1
J1
J2
1-7
Chapter 1: Introduction
1-5 Contacting Supermicro
Headquarters
Address: Super Micro Computer, Inc.
980 Rock Ave.
San Jose, CA 95131 U.S.A. Tel: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email:
marketing@supermicro.com (General Information)
support@supermicro.com (Technical Support)
Web Site: www.supermicro.com
Europe
Address: Super Micro Computer B.V.
Het Sterrenbeeld 28, 5215 ML
's-Hertogenbosch, The Netherlands Tel: +31 (0) 73-6400390 Fax: +31 (0) 73-6416525 Email: sales@supermicro.nl (General Information)
support@supermicro.nl (Technical Support)
rma@supermicro.nl (Customer Support)
Asia-Pacifi c
Address: Super Micro Computer, Inc.
4F, No. 232-1, Liancheng Rd.
Chung-Ho Dist., New Taipei City 235
Taiwan, R.O.C. Tel: +886-(2) 8226-3990 Fax: +886-(2) 8226-3991 Web Site:
www.supermicro.com.tw
Technical Support: Email:
support@supermicro.com.tw
Tel: +886-(2) 8226-5990
1-8
SUPERSERVER 2027TR-D70RF+ USER'S MANUAL
1-6 2U Twin: System Notes
As a 2U Twin2 confi guration, the SuperServer 2027TR-D70RF+ is a unique server system. With two system boards incorporated into a single chassis acting as two separate nodes, there are several points you should keep in mind.
Nodes
Each of the two serverboards act as a separate node in the system. As independant nodes, each may be powered off and on without affecting the others. In addition, each node is a hot-swappable unit that may be removed from the rear of the chassis. The nodes are connected to the server backplane by means of an adapter card.
Note: A guide pin is located between the upper and lower nodes on the inner chassis wall. This guide pin also acts as a “stop” when a node is fully installed. If too much force is used when inserting a node this pin may break off. Take care to slowly slide a node in until you hear the “click” of the locking tab seating itself.
System Power
Dual 1280 Watt power supplies are used to provide the power for all four serverboards. Each serverboard however, can be shut down independently of the other with the power button on its own control panel.
SAS/SATA Backplane/Drives
As a system, the SuperServer 2027TR-D70RF+ supports the use of twenty-four (24)
2.5" SAS/SATA drives. A single SAS/SATA backplane works to apply system-based control for power and fan speed functions, yet at the same time logically connects a set of twelve SAS/SATA drives to each serverboard. See the Drive Bay Installation/ Removal section in Chapter 6 for the logical hard drive and node confi guration.
Chapter 2: Server Installation
2-1
Chapter 2
Server Installation
2-1 Overview
This chapter provides a quick setup checklist to get your SuperServer 2027TR-D70RF+ up and running. Following these steps in the order given should enable you to have the system operational within a minimum amount of time. This quick setup assumes that your system has come to you with the processors and memory preinstalled. If your system is not already fully integrated with a serverboard, processors, system memory etc., please turn to the chapter or section noted in each step for details on installing specifi c components.
2-2 Unpacking the System
You should inspect the box the SuperServer 2027TR-D70RF+ was shipped in and note if it was damaged in any way. If the server itself shows damage you should le a damage claim with the carrier who delivered it.
Decide on a suitable location for the rack unit that will hold the SuperServer 2027TR-D70RF+. It should be situated in a clean, dust-free area that is well ventilated. Avoid areas where heat, electrical noise and electromagnetic fi elds are generated. You will also need it placed near a grounded power outlet. Read the Rack and Server Precautions in the next section.
2-3 Preparing for Setup
The box the SuperServer 2027TR-D70RF+ was shipped in should include two sets of rail assemblies, two rail mounting brackets and the mounting screws you will need to install the system into the rack. Follow the steps in the order given to complete the installation process in a minimum amount of time. Please read this section in its entirety before you begin the installation procedure outlined in the sections that follow.
2-2
SUPERSERVER 2027TR-D70RF+ USER'S MANUAL
Choosing a Setup Location
Leave enough clearance in front of the rack to enable you to open the front door
completely (~25 inches) and approximately 30 inches of clearance in the back of the rack to allow for suffi cient airfl ow and ease in servicing.
This product is for installation only in a Restricted Access Location (dedicated
equipment rooms, service closets and the like).
This product is not suitable for use with visual display work place devices
acccording to §2 of the the German Ordinance for Work with Visual Display Units.
2-4 Warnings and Precautions!
Rack Precautions
Ensure that the leveling jacks on the bottom of the rack are fully extended to
the fl oor with the full weight of the rack resting on them.
In single rack installation, stabilizers should be attached to the rack. In multiple
rack installations, the racks should be coupled together.
Always make sure the rack is stable before extending a component from the
rack.
You should extend only one component at a time - extending two or more
simultaneously may cause the rack to become unstable.
Server Precautions
Review the electrical and general safety precautions in Chapter 4.
Determine the placement of each component in the rack before you install the
rails.
Install the heaviest server components on the bottom of the rack fi rst, and then
work up.
Use a regulating uninterruptible power supply (UPS) to protect the server from
power surges, voltage spikes and to keep your system operating in case of a power failure.
Allow any hot plug drives and power supply modules to cool before touching
them.
Always keep the rack's front door and all panels and components on the servers
closed when not servicing to maintain proper cooling.
Chapter 2: Server Installation
2-3
Rack Mounting Considerations
Ambient Operating Temperature
If installed in a closed or multi-unit rack assembly, the ambient operating temperature of the rack environment may be greater than the ambient temperature of the room. Therefore, consideration should be given to installing the equipment in an environment compatible with the manufacturer’s maximum rated ambient temperature (Tmra).
Reduced Airfl ow
Equipment should be mounted into a rack so that the amount of airfl ow required for safe operation is not compromised.
Mechanical Loading
Equipment should be mounted into a rack so that a hazardous condition does not arise due to uneven mechanical loading.
Circuit Overloading
Consideration should be given to the connection of the equipment to the power supply circuitry and the effect that any possible overloading of circuits might have on overcurrent protection and power supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.
Reliable Ground
A reliable ground must be maintained at all times. To ensure this, the rack itself should be grounded. Particular attention should be given to power supply connections other than the direct connections to the branch circuit (i.e. the use of power strips, etc.).
Warning! To prevent bodily injury when mounting or servicing this unit in a rack, you must take special precautions to ensure that the system remains stable. The following guidelines are provided to ensure your safety:
This unit should be mounted at the bottom of the rack if it is the only unit in
the rack.
When mounting this unit in a partially fi lled rack, load the rack from the bottom
to the top with the heaviest component at the bottom of the rack.
If the rack is provided with stabilizing devices, install the stabilizers before
mounting or servicing the unit in the rack.
2-4
SUPERSERVER 2027TR-D70RF+ USER'S MANUAL
2-5 Installing the System into a Rack
This section provides information on installing the chassis into a rack unit with the rails provided. There are a variety of rack units on the market, which may mean that the assembly procedure will differ slightly from the instructions provided. You should also refer to the installation instructions that came with the rack unit you are using.
Note: This rail will t a rack between 26.5" and 36.4" deep.
Separating the Sections of the Rack Rails
The chassis package includes two rail assemblies in the rack mounting kit (Figure 2-1). Each assembly consists of two sections: an inner fi xed chassis rail that secures directly to the server chassis and an outer fi xed rack rail that secures directly to the rack itself.
Figure 2-1: Identifying the Outer Rail, Middle Rail and Inner Rails
(Left Rail Assembly Shown)
Inner Rail
Rail Assembly
(Shown with Rails
Retracted)
This Side Faces
Outward
Locking Tab
Middle Rail
Outer Rail
Chapter 2: Server Installation
2-5
Locking Tabs
Each inner rail has a locking tab. This tab locks the chassis into place when installed and pushed fully into the rack. These tabs also lock the chassis in place when fully extended from the rack. This prevents the server from coming completely out of the rack when when the chassis is pulled out for servicing.
Releasing the Inner Rail
Releasing Inner Rail from the Outer Rails (Figure 2-2)
1. Identify the left and right outer rail assemblies as described on page 2-4.
2. Pull the inner rail out of the outer rail until it is fully extended as illustrated below.
3. Press the locking tab down to release the inner rail.
4. Pull the inner rail all the way out.
5. Repeat steps 1-3 for the second outer rail.
Figure 2-2: Extending and Releasing the Inner Rail
1
2
1
1
1
3
1
4
2-6
SUPERSERVER 2027TR-D70RF+ USER'S MANUAL
Figure 2-4: Inner Rails Installed on the Chassis
Figure 2-3: Installing the Inner Rails
Installing The Inner Rails on the Chassis
Installing the Inner Rails (Figure 2-3 and Figure 2-4)
1. Confi rm that the left and right inner rails have been correctly identifi ed.
2. Place the inner rail fi rmly against the side of the chassis, aligning the hooks on the side of the chassis with the holes in the inner rail.
3. Slide the inner rail forward toward the front of the chassis until the rail clicks into the locked position, which secures the inner rail to the chassis.
4. Secure the inner rail to the chassis with the screws provided.
5. Repeat steps 1 through 4 above for the other inner rail.
1
3
1
4
1
4
1
2
Inner Rails
Chapter 2: Server Installation
2-7
Installing the Outer Rails on the Rack
Installing the Outer Rails (Figure 2-5)
1. Press upward on the locking tab at the rear end of the middle rail.
2. Push the middle rail back into the outer rail.
3. Hang the hooks of the front of the outer rail onto the slots on the front of the rack. If necessary, use screws to secure the outer rails to the rack, as illustrated above.
4. Pull out the rear of the outer rail, adjusting the length until it fi ts within the posts of the rack.
5. Hang the hooks of the rear portion of the outer rail onto the slots on the rear of the rack. If necessary, use screws to secure the rear of the outer rail to the rear of the rack.
6. Repeat steps 1-5 for the remaining outer rail.
Figure 2-5: Extending and Releasing the Outer Rails
1
3
1
4
1
1
1
2
2-8
SUPERSERVER 2027TR-D70RF+ USER'S MANUAL
Note: The fi gure above is for illustration purposes only. Always install servers to the bottom of the rack fi rst.
Standard Chassis Installation
Installing the Chassis into a Rack (Figure 2-6)
1. Confi rm that the inner rails are properly installed on the chassis.
2. Confi rm that the outer rails are correctly installed on the rack.
3. Pull the middle rail out from the front of the outer rail and make sure that the ball-bearing shuttle is at the front locking position of the middle rail.
4. Align the chassis inner rails with the front of the middle rails.
5. Slide the inner rails on the chassis into the middle rails, keeping the pressure even on both sides, until the locking tab of the inner rail clicks into the front of the middle rail, locking the chassis into the fully extended position.
6. Depress the locking tabs of both sides at the same time and push the chassis all the way into the rear of the rack.
7. If necessary for security purposes, use screws to secure the chassis handles to the front of the rack.
Figure 2-6: Installing into a Rack
Ball-Bearing
Shuttle
Chapter 2: Server Installation
2-9
Optional Quick Installation Method
The following quick installation method may be used to install the chassis onto a rack.
Installing the Chassis into a Rack
1. Install the whole rail assembly onto the rack as described on page 2-7.
2. Release the inner rail without retracting the middle rail.
3. Install the inner rails on the chassis as previously described on page 2-6.
4. Install the chassis onto the middle rail as described in the previous section. Warning: do not pick up the server with the front handles. They are designed
to pull the system from a rack only.
Stability hazard. The rack stabilizing mechanism must be in place, or the rack must be bolted to the fl oor before you slide the unit out for servicing. Failure to stabilize the rack can cause the rack to tip over.
2-6 Checking the Serverboard Setup
After you install the SUPERSERVER 2027TR-D70RF+ in the rack, you will need to open the unit to make sure the serverboard is properly installed and all the connections have been made.
Accessing the inside of the System
Before operating the SC217 chassis for the fi rst time, it is important to remove the protective fi lm over the cover of the chassis, in order to allow for proper ventilation and cooling.
Removing the Chassis Cover and Protective Film (Figure 2-7)
1. Confi rm that the power cord has been removed from the rear of both power
supplies.
2. Peel off the protective fi lm covering the top cover and the top of the chassis
3. Remove the two screws which secure the top cover onto the chassis as
shown above.
4. Lift the top cover up and off the chassis.
5. Check that all ventilation openings on the top cover and the top of the chassis
are clear and unobstructed.
6. Replace the chassis cover and reconnect the AC power cord.
2-10
SUPERSERVER 2027TR-D70RF+ USER'S MANUAL
Caution: Except for short periods of time, do NOT operate the server without the cover in place. The chassis cover must be in place to allow proper airfl ow and prevent overheating.
Checking the Components and Setup
1. You may have one or two processors already installed into the serverboard. Each processor needs its own heat sink. See Chapter 5 for instructions on processor and heat sink installation.
2. Your SUPERSERVER 2027TR-D70RF+ server system may have come with system memory already installed. Make sure all DIMMs are fully seated in their slots. For details on adding system memory, refer to Chapter 5.
3. If desired, you can install add-on cards to the system. See Chapter 5 for details on installing PCI add-on cards.
4. Make sure all power and data cables are properly connected and not blocking the chassis airfl ow. Also make sure that no cables are positioned in front of the fans. See Chapter 5 for details on cable connections.
Figure 2-7. Accessing the Inside of the System
Remove two
screws
Check Ventilation Openings
1
2
1
5
1
3
1
4
Chapter 2: Server Installation
2-11
2-7 Checking the Drive Bay Setup
Next, you should check to make sure the peripheral drives and the SATA drives have been properly installed and all connections have been made.
Checking the Drives
1. All drives are accessable from the front of the server. A hard drive can be installed and removed from the front of the chassis without removing the top chassis cover.
2. Depending upon your system's confi guration, your system may have one or more drives already installed. If you need to install hard drives, please refer to Chapter 6.
Checking the Airfl ow
1. Make sure there are no objects obstructing the airfl ow in and out of the chassis. In addition, if you are using a front bezel, make sure the bezel's fi lter is replaced periodically.
2. Except for brief periods while swapping hard drives, do not operate the server without drives or the drive carriers in the drive bays. Use only recommended server parts.
3. Make sure no wires or foreign objects obstruct airfl ow through the chassis. Pull all excess cabling out of the airfl ow path or use shorter cables.
4. The control panel LEDs inform you of system status. See “Chapter 3: System Interface” for details on the LEDs and the control panel buttons.
Providing Power
1. Plug the power cord(s) from the power supply unit(s) into a high-quality power strip that offers protection from electrical noise and power surges. It is recommended that you use an uninterruptible power supply (UPS).
2. Depress the power on button on the front of the chassis.
2-12
SUPERSERVER 2027TR-D70RF+ USER'S MANUAL
Notes
Loading...