The information in this User’s Manual has been carefully reviewed and is believed to be accurate.
The vendor assumes no responsibility for any inaccuracies that may be contained in this document,
makes no commitment to update or to keep current the information in this manual, or to notify any
person or organization of the updates. Please Note: For the most up-to-date version of this
manual, please see our web site at www.supermicro.com.
Super Micro Computer, Inc. ("Supermicro") reserves the right to make changes to the product
described in this manual at any time and without notice. This product, including software and documentation, is the property of Supermicro and/or its licensors, and is supplied only under a license.
Any use or reproduction of this product is not allowed, except as expressly permitted by the terms
of said license.
IN NO EVENT WILL SUPERMICRO BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL,
SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO
USE THIS PRODUCT OR DOCUMENTATION, EVEN IF ADVISED OF THE POSSIBILITY OF
SUCH DAMAGES. IN PARTICULAR, SUPERMICRO SHALL NOT HAVE LIABILITY FOR ANY
HARDWARE, SOFTW ARE, OR DA TA STORED OR USED WITH THE PRODUCT, INCLUDING THE
COSTS OF REPAIRING, REPLACING, INTEGRATING, INSTALLING OR RECOVERING SUCH
HARDWARE, SOFTWARE, OR DATA.
Any disputes arising between manufacturer and customer shall be governed by the laws of Santa
Clara County in the State of California, USA. The State of California, County of Santa Clara shall
be the exclusive venue for the resolution of any such disputes. Super Micro's total liability for all
claims will not exceed the price paid for the hardware product.
FCC Statement: This equipment has been tested and found to comply with the limits for a Class A
digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the manufacturer’s instruction manual, may cause harmful interference
with radio communications. Operation of this equipment in a residential area is likely to cause harmful
interference, in which case you will be required to correct the interference at your own expense.
California Best Management Practices Regulations for Perchlorate Materials: This Perchlorate warning applies only to products containing CR (Manganese Dioxide) Lithium coin cells. “Perchlorate
Material-special handling may apply. See www.dtsc.ca.gov/hazardouswaste/perchlorate”
WARNING: Handling of lead solder materials used in this
product may expose you to lead, a chemical known to the
State of California to cause birth defects and other reproductive harm.
Manual Revision 1.0b
Release Date: February 19, 2014
Unless you request and receive written permission from Super Micro Computer, Inc., you may not
copy any part of this document.
Information in this document is subject to change without notice. Other products and companies
referred to herein are trademarks or registered trademarks of their respective companies or mark
holders.
This manual is written for professional system integrators and PC technicians.
It provides information for the installation and use of the SuperServer 1027GRTRF/1027GR-TRFT. Installation and maintenance should be performed by experienced technicians only.
The 1027GR-TRF/1027GR-TRFT is based on the SC1 18GQ-R1800B 1U rackmount
server chassis and the Super X9DRG-HF/X9DRG-HTF serverboard. Please refer
to our web site for an up-to-date list of supported operating systems, processors
and memory. See Chapter 1 for a list of differences between the server models.
Manual Organization
Preface
Chapter 1: Introduction
The fi rst chapter provides a checklist of the main components included with the
server system and describes the main features of the Super X9DRG-HF/X9DRGHTF serverboard and the SC118GQ-R1800B chassis.
Chapter 2: Server Installation
This chapter describes the steps necessary to install the system into a rack and
check out the server confi guration prior to powering up the system. If your server
was ordered without the processor and memory components, this chapter will refer
you to the appropriate sections of the manual for their installation.
Chapter 3: System Interface
Refer to this chapter for details on the system interface, which includes the functions
and information provided by the control panel on the chassis as well as other LEDs
located throughout the system.
Chapter 4: Standardized Warning Statements
You should thoroughly familiarize yourself with this chapter for a general overview
of safety precautions that should be followed when installing and servicing the
system.
iii
Page 4
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual
Chapter 5: Advanced Serverboard Setup
Chapter 5 provides detailed information on the X9DRG-HF/X9DRG-HTF
serverboard, including the locations and functions of connectors, headers and jumpers. Refer to this chapter when adding or removing processors or main memory
and when reconfi guring the serverboard.
Chapter 6: Advanced Chassis Setup
Refer to Chapter 6 for detailed information on the SC1 18GQ-R1800B 1U rackmount
server chassis. You should follow the procedures given in this chapter when installing, removing or reconfi guring SATA or peripheral drives and when replacing system
power supply units and cooling fans.
Chapter 7: BIOS
The BIOS chapter includes an introduction to BIOS and provides detailed information on running the BIOS Setup Utility.
7-7 Secur it y ......................................................................................................... 7-30
7-8 Save & Exit ................................................................................................... 7-31
Appendix A BIOS POST Error Codes
Appendix B System Specifi cations
viii
Page 9
Chapter 1: Introduction
Chapter 1
Introduction
1-1 Overview
The SuperServer 1027GR-TRF/1027GR-TRFT series is a GPU-optimized server
comprised of two main subsystems: the SC118GQ-R1800B 1U server chassis and
the X9DRG-HF/X9DRG-HTF serverboard. Please refer to our web site for information on operating systems that have been certifi ed for use with the system (www.
supermicro.com).
• Ten 4-cm counter-rotating fans (FAN-0141L4)
• One air shroud (MCP-310-11802-0N)
• One 1U NVIDIA® Kepler™ side bracket (MCP-240-00117-0N)
• Two passive CPU heatsinks (one each of SNK-P0047PS and SNK-P0047PSC)
• Riser Cards
One RSC-R1UG-E16A-X9 for PCI-Express 3.0 x16 card. left front side
One RSC-R1UG-E16B-X9 for PCI-Express 3.0 x16 card, left rear side
One RSC-R1UG-E16AR-X9 for PCI-Express 3.0 x16 card, right front side
One RSC-R1UG-E16R-X9 for PCI-Express 3.0 x8 low-profi le card, above
serverboard
• Three power cables for GPU cards (CBL-0333L)
• SATA Accessories
One SAS backplane (BPN-SAS-118G-4)
Four hot-swap drive carriers (MCP-220-00047-0B)
Four SATA cables (CBL-0207L, CBL-0227L, 2 pcs. of CBL-0228L)
One SGPIO cable (CBL-0157L)
• One rail set (MCP-290-00054-0N)
1-1
Page 10
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual
Note: For your system to work properly, please follow the links below to download
all necessary drivers/utilities and the user’s manual for your server.
• If you have any questions, please contact our support team at:
support@supermicro.co
1-2 Serverboard Features
At the heart of the SuperServer 1027GR-TRF/1027GR-TRFT server is the X9DRGHF/X9DRG-HTF, a dual processor serverboard based on the Intel C602 chipset.
Below are the main features of the X9DRG-HF/X9DRG-HTF. (See Figure 1-1 for a
block diagram of the chipset).
Processors
The X9DRG-HF/X9DRG-HTF supports two Intel Xeon E5-2600 series processors in
LGA 2011 sockets (Socket R). Please refer to the serverboard description pages on
our web site for a complete listing of supported processors (www.supermicro.com).
Memory
The X9DRG-HF/X9DRG-HTF has eight DIMM slots that can support up to 512 GB
registered ECC LDIMMs or 256 GB of DDR3-1866/1600/1333/1066/800 RDIMMs.
Modules of the same size and speed are recommended. See Chapter 5 for details.
Serial ATA
A SATA controller is integrated into the chipset to provide a 4-port SATA subsystem,
which is RAID 0, 1, 5 and 10 supported. Two of these are SATA 3.0 ports and two
are SATA 2.0 ports. The SATA drives are hot-swappable units.
Note: The operati ng system yo u use must h ave R AID su ppor t to e nable t he hotswap capability and RAI D function of the SATA drives.
PCI Expansion Slots
The X9DRG-HF/X9DRG-HTF has three PCI-Express 3.0 x16 slots to support
three double-width GPU cards. Additional slots support one PCI-Express 3.0 x8
low-profi le card.
1-2
Page 11
Chapter 1: Introduction
Onboard Controllers/Ports
The color-coded I/O ports include one COM port (an additional COM header is located on the serverboard), a VGA (monitor) port, two USB 2.0 ports, two Gb Ethernet
LAN ports (two 10 Gb ports on the X9DRG-HTF) and one dedicated IPMI LAN port.
IPMI
IPMI (Intelligent Platform Management Interface) is a hardware-level interface specifi cation that provides remote access, monitoring and administration for Supermicro
server platforms. IPMI allows server administrators to view a server’s hardware
status remotely, receive an alarm automatically if a failure occurs, and power cycle
a system that is non-responsive.
1-3 Server Chassis Features
System Power
The SC118GQ-R1800B features a high-effi ciency, redundant 1800W power supply
composed of two separate power modules. This power redundancy feature allows
you to replace a failed power supply without shutting down the system. See Chapter
6 for details.
SATA Subsystem
The SC118GQ-R1800B chassi s inc l ude s fo ur 2. 5" d r ive bays , whi c h may be u se d
to house hot -swap pable SATA drives. RA ID 0, 1, 5 and 10 are suppo rte d.
Front Control Panel
The control panel provides a system monitoring and control interface. LEDs indicate
system power, HDD activity, network activity, and a system overheat/fan fail/ UID
LED. A main power button and a system reset button are also included.
Cooling System
The SC118GQ-R1800B has an innovative cooling design that includes ten 4-cm
counter-rotating PWM (Pulse Width Modulated) fans. The power supply modules
also include a cooling fan. All chassis and power supply fans operate continuously.
An air shrouds is included to further help cool the GPUs. See note on the following
page regarding fan control.
1-3
Page 12
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual
1-4 GPU Subsystem
The 1027GR-TRF/1027GR-TRFT server represents one of Supermicro's massively
parallel processing multiple-GPU servers, with support for up to three NVIDIA®
Fermi™ or Kepler™ GPUs, which place this system at the forefront of today's GPU
computing solutions.
Please refer to the NVIDIA web site (www.nvidia.com) for details on Fermi GPUs.
Notes
The GPUs can be bundled with the system as follows:
1027GR-TRF/1027GR-TRFT-FM309: includes three NVIDIA Fermi M2090 GPUs.
1027GR-TRF/1027GR-TRFT-FM375: includes three NVIDIA Fermi M2075 GPUs
NVIDIA® Kepler™ GPUs (requires their own mounting brackets for installation: p/n
MCP-240-00117-0N)
1-4
Page 13
Chapter 1: Introduction
Figure 1-1. Intel C602 Chipset:
System Block Diagram
Note: This is a general block diagram. Please see Chapter 5 for details.
4F, No. 232-1, Liancheng Rd.
Chung-Ho Dist., New Taipei City 235
Taiwan
Tel: +886-(2) 8226-3990
Fax: +886-(2) 8226-3991
Web Site:www.supermicro.com.tw
Technical Support:
Email:support@supermicro.com.tw
Tel: 886-2-8228-1366, ext.132 or 139
1-6
Page 15
Chapter 2: Server Installation
Chapter 2
Server Installation
2-1 Overview
This chapter provides a quick setup checklist to get your system up and running.
Following these steps in the order given should enable you to have the system
operational within a minimum amount of time. This quick setup assumes that your
system has come to you with the processors and memory preinstalled. If your system is not already fully integrated with a serverboard, processors, system memory
etc., please turn to the chapter or section noted in each step for details on installing
specifi c components.
2-2 Unpacking the System
You should inspect the box the system was shipped in and note if it was damaged
in any way. If the server itself shows damage you should fi le a damage claim with
the carrier who delivered it.
Decide on a suitable location for the rack unit that will hold the server. It should
be situated in a clean, dust-free area that is well ventilated. Avoid areas where
heat, electrical noise and electromagnetic fi elds are generated. You will also need
it placed near a grounded power outlet. Read the Rack and Server Precautions in
the next section.
2-3 Preparing for Setup
The box the server was shipped in should include two sets of rail assemblies, two
rail mounting brackets and the mounting screws you will need to install the system
into the rack. Follow the steps in the order given to complete the installation process
in a minimum amount of time. Please read this section in its entirety before you
begin the installation procedure outlined in the sections that follow.
Choosing a Setup Location
• Leave enough clearance in front of the rack to enable you to open the front door
completely (~25 inches) and approximately 30 inches of clearance in the back
of the rack to allow for suffi cient airfl ow and ease in servicing.This product is for
installation only in a Restricted Access Location (dedicated equipment rooms,
service closets and the like).
2-1
Page 16
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual
• This product is not suitable for use with visual display work place devices
acccording to §2 of the the German Ordinance for Work with Visual Display Units.
2-4 Warnings and Precautions
Rack Precautions
• Ensure that the leveling jacks on the bottom of the rack are fully extended to
the fl oor with the full weight of the rack resting on them.
• In single rack installation, stabilizers should be attached to the rack. In multiple
rack installations, the racks should be coupled together.
• Always make sure the rack is stable before extending a component from the
rack.
• You should extend only one component at a time - extending two or more si-
multaneously may cause the rack to become unstable.
• Rack-mounted equipment should not be used as a shelf or work space.
Server Precautions
• Review the electrical and general safety precautions in Chapter 4.
• Determine the placement of each component in the rack before you install the
rails.
• Install the heaviest server components on the bottom of the rack fi rst, and then
work up.
• Use a regulating uninterruptible power supply (UPS) to protect the server from
power surges, voltage spikes and to keep your system operating in case of a
power failure.
• Allow the hot plug SATA drives and power supply modules to cool before touch-
ing them.
• Always keep the rack's front door and all panels and components on the servers
closed when not servicing to maintain proper cooling.
2-2
Page 17
Chapter 2: Server Installation
Rack Mounting Considerations
Ambient Operating Temperature
If installed in a closed or multi-unit rack assembly, the ambient operating temperature of the rack environment may be greater than the ambient temperature of the
room. Therefore, consideration should be given to installing the equipment in an
environment compatible with the manufacturer’s maximum rated ambient temperature (Tmra).
Reduced Airfl ow
Equipment should be mounted into a rack so that the amount of airfl ow required
for safe operation is not compromised.
Mechanical Loading
Equipment should be mounted into a rack so that a hazardous condition does not
arise due to uneven mechanical loading.
Circuit Overloading
Consideration should be given to the connection of the equipment to the power
supply circuitry and the effect that any possible overloading of circuits might have
on overcurrent protection and power supply wiring. Appropriate consideration of
equipment nameplate ratings should be used when addressing this concern.
Reliable Ground
A reliable ground must be maintained at all times. To ensure this, the rack itself
should be grounded. Particular attention should be given to power supply connections other than the direct connections to the branch circuit (i.e. the use of power
strips, etc.).
Warning! To prevent bodily injury when mounting or servicing this unit in a
rack, you must take special precautions to ensure that the system remains
stable. The following guidelines are provided to ensure your safety:
• This unit should be mounted at the bottom of the rack if it is the only unit in
the rack.
• When mounting this unit in a partially fi lled rack, load the rack from the bottom
to the top with the heaviest component at the bottom of the rack.
• If the rack is provided with stabilizing devices, install the stabilizers before
mounting or servicing the unit in the rack.
2-3
Page 18
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual
2-4 Installing the System into a Rack
This section provides information on installing the SC118GQ chassis into a rack
unit with the rails provided. There are a variety of rack units on the market, which
may mean that the assembly procedure will differ slightly. You should also refer to
the installation instructions that came with the rack unit you are using.
Note: This rail will fi t a rack between 26" and 33.5" deep.
Identifying the Sections of the Rack Rails
The chassis package includes two rack rail assemblies in the rack mounting kit.
Each assembly consists of two sections: an inner fi xed chassis rail that secures
directly to the server chassis and an outer fi xed rack rail that secures directly to
the rack itself.
Figure 2-1. Identifying the Sections of the Rack Rails
Inner Rail (preattached
to the chassis)
Inner Rail
Extension:
attach to the
chassis
Outer Rails:
slide together, then
attach to the front
and rear brackets
Warning: do not pick up the server with the front handles. They are de-
signed to pull the system from a rack only.
Front and Rear
Brackets: attach to
the rack
2-4
Page 19
Chapter 2: Server Installation
Installing the Inner Rail Extensions
The SC118GQ chassis includes a set of inner rack rails in two sections: inner rails
(A) and inner rail extensions (B). The inner rails are preattached and do not interfere
with normal use of the chassis if you decide not to install to a server rack. Attaching
the inner rail extensions to to the inner rails stabilizes the chassis within the rack.
Installing the Inner Rail Extensions
1. Place the inner rail extensions (B) over the preattached inner rails (A) which
are attached to the side of the chassis. Align the hooks of the inner rail with
the rail extension holes. Make sure the extension faces "outward" just like the
inner rail.
2. Slide the extension toward the front of the chassis.
3. Secure the chassis with screws as illustrated.
4. Repeat steps 1-3 for the other inner rail extension.
Figure 2-2. Installing the Inner Rails
2-5
1
1
2
1
3
1
Page 20
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual
Assembling the Outer Rails
Each outer rail is in two sections that must be assembled before mounting on to
the rack.
Assembling the Outer Rails
1. Identify the left and right outer rails by examining the ends, which bend
outward.
2. Slide the front section of the outer rail (A), into the rear section of the outer
rail (B).
Figure 2-3. Assembling the Outer Rails
Secure to the
Slide outer rails
together
rear of the rack
Secure to the
front of the rack
Stability hazard. The rack stabilizing mechanism must be in place, or the
rack must be bolted to the fl oor before you slide the unit out for servicing.
Failure to stabilize the rack can cause the rack to tip over.
A
1
B
1
Assembling the sections of
the outer rail
Outer rail assembled
2-6
Page 21
Chapter 2: Server Installation
Installing the Outer Rails onto the Rack
Outer Rail Installation
1. Adjust the outer rails to the proper length so that the outer rail fi ts snugly
within the rack.
2. Align the holes on the front of the outer rail, with the holes on the front of the
rack (C) and secure with the screws provided.
3. Align the holes on the rear of the outer rail to the holes on the rack (D) and
secure with the screws provided.
4. Repeat the procedure with the second outer rail assembly.
Figure 2-4. Installing the Outer Rails to the Rack
C
1
D
1
2-7
Page 22
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual
Installing and Removing the Chassis From a Rack
Installation into a Rack
1. Slide the inner rail extensions into the front of the outer rails.
2. Push the chassis backward into the rack until it clicks into the locked postion.
Removing the Chassis From a Rack
1. Press the outer rail latch to release the chassis.
2. Carefully slide the chassis forward, off the outer rails and out of the chassis.
Note: fi gures are for illustrative purposes only. Always install servers starting from
the bottom of a rack fi rst.
2-8
Page 23
Chapter 2: Server Installation
Installing the Server into a Telco Rack
Optional brackets are needed to install the server to a telco (open type) rack.
To install the server into a Telco type rack, use the two L-shaped brackets on either
side of the chassis (four total). First, determine how far follow the server will extend
out the front of the rack. Larger chassis should be positioned to balance the weight
between front and back. If a bezel is included on your server, remove it. Then attach the two front brackets to each side of the chassis, then the two rear brackets
positioned with just enough space to accommodate the width of the telco rack. Finish
by sliding the chassis into the rack and tightening the brackets to the rack.
Figure 2-7. Installing the Server into a Telco Rack
2-9
Page 24
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual
Notes
2-10
Page 25
Chapter 3: System Interface
Chapter 3
System Interface
3-1 Overview
There are several LEDs on the control panel as well as others on the drive carriers to keep you constantly informed of the overall status of the system as well as
the activity and health of specifi c components. There are also two buttons on the
chassis control panel. This chapter explains the meanings of all LED indicators and
the appropriate response you may need to take.
3-2 Control Panel Buttons
There are two push-buttons located on the front of the chassis: a reset button and
a power on/off button.
Reset
Use the reset button to reboot the system.
Power
The main power button is used to apply or remove power from the power supply
to the server system. Turning off system power with this button removes the main
power but keeps standby power supplied to the system.
3-1
Page 26
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual
3-3 Control Panel LEDs
The two control panels are located on the front of the SC118GQ chassis. Each
control panel has six LEDs. These LEDs provide critical information related to different parts of the system. This section explains what each LED indicates when
illuminated and any action that may be required..
Overheat/Fan Fail/UID LED
When this LED fl ashes it in dic ate s a fan f ailu re. W hen c ont inu ous ly on (not fl ash-
ing) it indicates an overheat condition, which may be caused by cables obstructing
the airfl ow in the system or the ambient room temperature being too warm. Check
the rout ing of the cab les and make sure that a ll fans are pres ent and operati ng
norma lly. Also ch eck to make sur e that the a ir shrou ds are inst alled a nd that th e
top cover i s on. Finally, verif y that t he heatsi nks are inst alled pr operl y. This LED
will remain fl ashing or on as long as the overheat condition exists. When used with
a UID-compatible motherboard, the UID function is used to turn on or off the blue
light function of the the LED. Once the blue light is activated through the system
software, the unit can be easily located in very large racks and server banks.
2
NIC2
Indicates network activity on GLAN2 when fl ashing .
1
NIC1
Indicates network activity on GLAN1 when fl ashing .
3-2
Page 27
Chapter 3: System Interface
HDD
This ligh t indic ates SATA and/or per ipher al drive ac tivit y whe n fl ashing.
Power
Indic ates power is bein g supplied to the sy stem's power supply u nits. This LED
should normally be illuminated when the system is operating.
3-4 Drive Carrier LEDs
• Green: Each har d drive car rier (for use w ith SATA dr ives) has a green LED.
When ill umin ated, th is gre en LED (on th e fro nt of th e SATA drive car r ier) ind icates drive activity. A connection to the backplane enables this LED to blink on
and of f w h e n t hat p a rticu l ar d r i ve i s b e in g a c cessed. Please refer to Chapter 6
for instructions on replacing failed SATA drives.
• Red: The red LED to indicate a SATA drive failure. If one of the SATA drives
fail, you should be notifi ed by your system management software. Please refer
to Chapter 6 for instructions on replacing failed SATA drives.
3-3
Page 28
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual
Notes
3-4
Page 29
Chapter 4: Warning Statements for AC Systems
Chapter 4
Standardized Warning Statements for AC Systems
4-1 About Standardized Warning Statements
The following statements are industry standard warnings, provided to warn the user
of situations which have the potential for bodily injury. Should you have questions
or experience difficulty, contact Supermicro's Technical Support department
for assistance. Only certifi ed technicians should attempt to install or confi gure
components.
Read this appendix in its entirety before installing or confi guring components in the
Supermicro chassis.
These warnings may also be found on our web site at http://www.supermicro.com/
about/policies/safety_information.cfm.
Warning Defi nition
Warning!
This warning symbol means danger. You are in a situation that could cause bodily
injury. Before you work on any equipment, be aware of the hazards involved with
electrical circuitry and be familiar with standard practices for preventing accidents.
Warnung
WICHTIGE SICHERHEITSHINWEISE
Dieses Warnsymbol bedeutet Gefahr. Sie befi nden sich in einer Situation, die zu
Verletzungen führen kann. Machen Sie sich vor der Arbeit mit Geräten mit den
Gefahren elektrischer Schaltungen und den üblichen Verfahren zur Vorbeugung
vor Unfällen vertraut. Suchen Sie mit der am Ende jeder Warnung angegebenen
Anweisungsnummer nach der jeweiligen Übersetzung in den übersetzten
Sicherheitshinweisen, die zusammen mit diesem Gerät ausgeliefert wurden.
BEWAHREN SIE DIESE HINWEISE GUT AUF.
INSTRUCCIONES IMPORTANTES DE SEGURIDAD
Este símbolo de aviso indica peligro. Existe riesgo para su integridad física. Antes
de manipular cualquier equipo, considere los riesgos de la corriente eléctrica y
familiarícese con los procedimientos estándar de prevención de accidentes. Al
fi nal de cada advertencia encontrará el número que le ayudará a encontrar el texto
traducido en el apartado de traducciones que acompaña a este dispositivo.
GUARDE ESTAS INSTRUCCIONES.
IMPORTANTES INFORMATIONS DE SÉCURITÉ
Ce symbole d'avertissement indique un danger. Vous vous trouvez dans une
situation pouvant entraîner des blessures ou des dommages corporels. Avant
de travailler sur un équipement, soyez conscient des dangers liés aux circuits
électriques et familiarisez-vous avec les procédures couramment utilisées pour
éviter les accidents. Pour prendre connaissance des traductions des avertissements
fi gurant dans les consignes de sécurité traduites qui accompagnent cet appareil,
référez-vous au numéro de l'instruction situé à la fi n de chaque avertissement.
이 경고 기호는 위험이 있음을 알려 줍니다. 작업자의 신체에 부상을 야기 할 수
있는 상태에 있게 됩니다. 모든 장비에 대한 작업을 수행하기 전에 전기회로와
관련된 위험요소들을 확인하시고 사전에 사고를 방지할 수 있도록 표준
작업절차를 준수해 주시기 바랍니다.
해당 번역문을 찾기 위해 각 경고의 마지막 부분에 제공된 경고문 번호를
참조하십시오
BELANGRIJKE VEILIGHEIDSINSTRUCTIES
Dit waarschuwings symbool betekent gevaar. U verkeert in een situatie die
lichamelijk letsel kan veroorzaken. Voordat u aan enige apparatuur gaat werken,
dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico's
en dient u op de hoogte te zijn van de standaard procedures om ongelukken te
voorkomen. Gebruik de nummers aan het eind van elke waarschuwing om deze te
herleiden naar de desbetreffende locatie.
BEWAAR DEZE INSTRUCTIES
4-3
Page 32
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual
Installation Instructions
Warning!
Read the installation instructions before connecting the system to the power source.
設置手順書
システムを電源に接続する前に、設置手順書をお読み下さい。
警告
将此系统连接电源前,请先阅读安装说明。
警告
將系統與電源連接前,請先閱讀安裝說明。
Warnung
Vor dem Anschließen des Systems an die Stromquelle die Installationsanweisungen
lesen.
¡Advertencia!
Lea las instrucciones de instalación antes de conectar el sistema a la red de
alimentación.
Attention
Avant de brancher le système sur la source d'alimentation, consulter les directives
Waarschuwing
Raadpleeg de installatie-instructies voordat u het systeem op de voedingsbron
aansluit.
4-4
Page 33
Chapter 4: Warning Statements for AC Systems
Circuit Breaker
Warning!
This product relies on the building's installation for short-circuit (overcurrent)
protection. Ensure that the protective device is rated not greater than: 250 V, 20 A.
이 제품은 전원의 단락(과전류)방지에 대해서 전적으로 건물의 관련 설비에
의존합니다. 보호장치의 정격이 반드시 250V(볼트), 20A(암페어)를 초과하지
않도록 해야 합니다.
Waarschuwing
Dit product is afhankelijk van de kortsluitbeveiliging (overspanning) van
uw electrische installatie. Controleer of het beveiligde aparaat niet groter
gedimensioneerd is dan 220V, 20A.
Power Disconnection Warning
Warning!
The system must be disconnected from all sources of power and the power cord
removed from the power supply module(s) before accessing the chassis interior to
install or remove system components.
電源切断の警告
システムコンポーネントの取り付けまたは取り外しのために、シャーシー内部にアクセス
するには、
システムの電源はすべてのソースから切断され、電源コードは電源モジュールから取り
外す必要があります。
警告
在你打开机箱并安装或移除内部器件前,必须将系统完全断电,并移除电源线。
警告
在您打開機殼安裝或移除內部元件前,必須將系統完全斷電,並移除電源線。
Warnung
Das System muss von allen Quellen der Energie und vom Netzanschlusskabel
getrennt sein, das von den Spg.Versorgungsteilmodulen entfernt wird, bevor es
auf den Chassisinnenraum zurückgreift, um Systemsbestandteile anzubringen oder
zu entfernen.
4-6
Page 35
Chapter 4: Warning Statements for AC Systems
ילמשחקותינינפמהרהזא
!הרהזא
¡Advertencia!
El sistema debe ser disconnected de todas las fuentes de energía y del cable
eléctrico quitado de los módulos de fuente de alimentación antes de tener acceso
el interior del chasis para instalar o para quitar componentes de sistema.
Attention
Le système doit être débranché de toutes les sources de puissance ainsi que de
son cordon d'alimentation secteur avant d'accéder à l'intérieur du chassis pour
installer ou enlever des composants de systéme.
למשחה תורוקמ לכמ תכרעמה תא קתנל שי ריסהל שיו קפסהמ ילמשחה לבכ תא
시스템에 부품들을 장착하거나 제거하기 위해서는 섀시 내부에 접근하기 전에
반드시 전원 공급장치로부터 연결되어있는 모든 전원과 전기코드를 분리해주어야
합니다.
Waarschuwing
Voordat u toegang neemt tot het binnenwerk van de behuizing voor het installeren
of verwijderen van systeem onderdelen, dient u alle spanningsbronnen en alle
stroomkabels aangesloten op de voeding(en) van de behuizing te verwijderen
Waarschuwing
Deze apparatuur mag alleen worden geïnstalleerd, vervangen of hersteld door
geschoold en gekwalifi ceerd personeel.
Restricted Area
Warning!
This unit is intended for installation in restricted access areas. A restricted access
area can be accessed only through the use of a special tool, lock and key, or other
means of security. (This warning does not apply to workstations).
이 장치는 접근이 제한된 구역에 설치하도록 되어있습니다. 특수도구, 잠금 장치 및
키, 또는 기타 보안 수단을 통해서만 접근 제한 구역에 들어갈 수 있습니다.
Waarschuwing
Dit apparaat is bedoeld voor installatie in gebieden met een beperkte toegang.
Toegang tot dergelijke gebieden kunnen alleen verkregen worden door gebruik te
maken van speciaal gereedschap, slot en sleutel of andere veiligheidsmaatregelen.
Battery Handling
Warning!
There is the danger of explosion if the battery is replaced incorrectly. Replace the
battery only with the same or equivalent type recommended by the manufacturer.
Dispose of used batteries according to the manufacturer's instructions
Warnung
Bei Einsetzen einer falschen Batterie besteht Explosionsgefahr. Ersetzen Sie die
Batterie nur durch den gleichen oder vom Hersteller empfohlenen Batterietyp.
Entsorgen Sie die benutzten Batterien nach den Anweisungen des Herstellers.
Attention
Danger d'explosion si la pile n'est pas remplacée correctement. Ne la remplacer
que par une pile de type semblable ou équivalent, recommandée par le fabricant.
Jeter les piles usagées conformément aux instructions du fabricant.
¡Advertencia!
Existe peligro de explosión si la batería se reemplaza de manera incorrecta.
Reemplazar la batería exclusivamente con el mismo tipo o el equivalente
recomendado por el fabricante. Desechar las baterías gastadas según las
instrucciones del fabricante.
배터리가 올바르게 교체되지 않으면 폭발의 위험이 있습니다. 기존 배터리와
동일하거나 제조사에서 권장하는 동등한 종류의 배터리로만 교체해야 합니다.
제조사의 안내에 따라 사용된 배터리를 처리하여 주십시오.
Waarschuwing
Er is ontploffi ngsgevaar indien de batterij verkeerd vervangen wordt. Vervang de
batterij slechts met hetzelfde of een equivalent type die door de fabrikant aanbevolen
wordt. Gebruikte batterijen dienen overeenkomstig fabrieksvoorschriften afgevoerd
te worden.
4-11
Page 40
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual
דחאקפסמרתויםייקםא
!הרהזא
Redundant Power Supplies
Warning!
This unit might have more than one power supply connection. All connections must
be removed to de-energize the unit.
冗長電源装置
このユニットは複数の電源装置が接続されている場合があります。
ユニットの電源を切るためには、すべての接続を取り外さなければなりません。
警告
此部件连接的电源可能不止一个,必须将所有电源断开才能停止给该部件供电。
警告
此裝置連接的電源可能不只一個,必須切斷所有電源才能停止對該裝置的供電。
Warnung
Dieses Gerät kann mehr als eine Stromzufuhr haben. Um sicherzustellen, dass
der Einheit kein trom zugeführt wird, müssen alle Verbindungen entfernt werden.
¡Advertencia!
Puede que esta unidad tenga más de una conexión para fuentes de alimentación.
Para cortar por completo el suministro de energía, deben desconectarse todas las
conexiones.
Attention
Cette unité peut avoir plus d'une connexion d'alimentation. Pour supprimer toute
tension et tout courant électrique de l'unité, toutes les connexions d'alimentation
Waarschuwing
De uiteindelijke verwijdering van dit product dient te geschieden in overeenstemming
met alle nationale wetten en reglementen.
Hot Swap Fan Warning
Warning!
The fans might still be turning when you remove the fan assembly from the chassis.
Keep fi ngers, screwdrivers, and other objects away from the openings in the fan
assembly's housing.
ファン・ホットスワップの警告
シャーシから冷却ファン装置を取り外した際、ファンがまだ回転している可能性がありま
す。ファンの開口部に、指、ドライバー、およびその他のものを近づけないで下さい。
警告
当您从机架移除风扇装置,风扇可能仍在转动。小心不要将手指、螺丝起子和其他
物品太靠近风扇
4-16
Page 45
Chapter 4: Warning Statements for AC Systems
警告
當您從機架移除風扇裝置,風扇可能仍在轉動。小心不要將手指、螺絲起子和其他
物品太靠近風扇。
Warnung
Die Lüfter drehen sich u. U. noch, wenn die Lüfterbaugruppe aus dem Chassis
genommen wird. Halten Sie Finger, Schraubendreher und andere Gegenstände
von den Öffnungen des Lüftergehäuses entfernt.
¡Advertencia!
Los ventiladores podran dar vuelta cuando usted quite ell montaje del ventilador
del chasis. Mandtenga los dedos, los destornilladores y todos los objetos lejos de
las aberturas del ventilador
Attention
Il est possible que les ventilateurs soient toujours en rotation lorsque vous retirerez
le bloc ventilateur du châssis. Prenez garde à ce que doigts, tournevis et autres
objets soient éloignés du logement du bloc ventilateur.
섀시로부터 팬 조립품을 제거할 때 팬은 여전히 회전하고 있을 수 있습니다. 팬
조림품 외관의 열려있는 부분들로부터 손가락 및 스크류드라이버, 다른 물체들이
가까이 하지 않도록 배치해 주십시오.
Waarschuwing
Het is mogelijk dat de ventilator nog draait tijdens het verwijderen van het
ventilatorsamenstel uit het chassis. Houd uw vingers, schroevendraaiers
en eventuele andere voorwerpen uit de buurt van de openingen in de
ventilatorbehuizing.
4-17
Page 46
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual
Power Cable and AC Adapter
Warning!
When installing the product, use the provided or designated connection cables,
power cables and AC adaptors. Using any other cables and adaptors could cause
a malfunction or a fi re. Electrical Appliance and Material Safety Law prohibits the
use of UL or CSA -certifi ed cables (that have UL/CSA shown on the code) for any
other electrical devices than products designated by Supermicro only.
Warnung
Bei der Installation des Produkts, die zur Verfügung gestellten oder benannt
Anschlusskabel, Stromkabel und Netzteile. Verwendung anderer Kabel und Adapter
kann zu einer Fehlfunktion oder ein Brand entstehen. Elektrische Geräte und
Material Safety Law verbietet die Verwendung von UL-oder CSA-zertifi zierte Kabel,
UL oder CSA auf der Code für alle anderen elektrischen Geräte als Produkte von
Supermicro nur bezeichnet gezeigt haben.
¡Advertencia!
Al instalar el producto, utilice los cables de conexión previstos o designados, los
cables y adaptadores de CA. La utilización de otros cables y adaptadores podría
ocasionar un mal funcionamiento o un incendio. Aparatos Eléctricos y la Ley de
Seguridad del Material prohíbe el uso de UL o CSA cables certifi cados que tienen
UL o CSA se muestra en el código de otros dispositivos eléctricos que los productos
designados por Supermicro solamente.
4-18
Page 47
Chapter 4: Warning Statements for AC Systems
אתמו םיילמשחמ י
Attention
Lors de l'installation du produit, utilisez les bables de connection fournis ou désigné.
L'utilisation d'autres cables et adaptateurs peut provoquer un dysfonctionnement
ou un incendie. Appareils électroménagers et de loi sur la sécurité Matériel interdit
l'utilisation de UL ou CSA câbles certifi és qui ont UL ou CSA indiqué sur le code
pour tous les autres appareils électriques que les produits désignés par Supermicro
seulement.
제품을 설치할 때에는 제공되거나 지정된 연결케이블과 전원케이블, AC어댑터를
사용해야 합니다. 그 밖의 다른 케이블들이나 어댑터들은 고장 또는 화재의 원인이
될 수 있습니다. 전기용품안전법 (Electrical Appliance and Material Safety
Law)은 슈퍼마이크로에서 지정한 제품들 외에는 그 밖의 다른 전기 장치들을
위한 UL또는 CSA에서 인증한 케이블(전선 위에 UL/CSA가 표시)들의 사용을
금지합니다.
Waarschuwing
Bij het installeren van het product, gebruik de meegeleverde of aangewezen kabels,
stroomkabels en adapters. Het gebruik van andere kabels en adapters kan leiden
tot een storing of een brand. Elektrisch apparaat en veiligheidsinformatiebladen wet
verbiedt het gebruik van UL of CSA gecertifi ceerde kabels die UL of CSA die op
de code voor andere elektrische apparaten dan de producten die door Supermicro
alleen.
4-19
Page 48
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual
Notes
4-20
Page 49
Chapter 5: Advanced Serverboard Setup
Chapter 5
Advanced Serverboard Setup
This chapter covers the steps required to install the X9DRG-HF/X9DRG-HTF
serverboard into the chassis, connect the data and power cables and install add-on
cards. All serverboard jumpers and connections are also described. A layout and
quick reference chart are included in this chapter for your reference. Remember to
completely close the chassis when you have fi nished working with the serverboard
to better cool and protect the system.
5-1 Handling the Serverboard
Electrostatic Discharge (ESD) can damage electronic com ponents. To prevent damage to any printed circuit boards (PCBs), it is important to handle them very carefully
(see previous chapter). To prevent the serverboard from bending, keep one hand
under the center of the board to support it when handling. The following measures
are generally suffi cient to protect your equipment from electric static discharge.
Precautions
• Use a grounded wrist strap designed to prevent Electrostatic Discharge
(ESD).
• Touch a grounded metal object before removing any board from its antistatic
bag.
• Handle a board by its edges only; do not touch its components, peripheral chips,
memory modules or gold contacts.
• When handling chips or modules, avoid touching their pins.
• Put the serverboard, add-on cards and peripherals back into their antistatic
bags when not in use.
• For grounding purposes, make sure your computer chassis provides excellent
conductivity between the power supply, the case, the mounting fasteners and
the serverboard.
5-1
Page 50
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual
Unpacking
The serverboard is shipped in antistatic packaging to avoid electrical static dis-
charge. When unpacking the board, make sure the person handling it is static
protected.
5-2 Serverboard Installation
This section explains the fi rst step of physically mounting the X9DRG-HF/X9DRG-
HTF into the SC1 18GQ chassis. Following the steps in the order given will eliminate
the most common problems encountered in such an installation. To remove the
serverboard, follow the procedure in reverse order.
Installing to the Chassis
1. Access the inside of the system by removing the screws from the back lip of
the top cover of the chassis, then pull the cover off.
2. Make sure that the I/O ports on the serverboard align properly with their
respective holes in the I/O shield at the back of the chassis.
3. Carefully mount the serverboard to the serverboard tray by aligning the board
holes with the raised metal standoffs that are visible in the chassis.
4. Insert screws into all the mounting holes on your serverboard that line up
with the standoffs and tighten until snug (if you screw them in too tight, you
might strip the threads). Metal screws provide an electrical contact to the
serverboard ground to provide a continuous ground for the system.
5. Install the processors and make all necessary cable connections, as described in the sections that follow.
Warning: To avoid damaging the serverboard and its components, do not apply
any force greater than 8 lbs. per square inch when installing a screw into a mounting hole.
5-2
Page 51
Chapter 5: Advanced Serverboard Setup
5-3 Connecting Cables
Now that the serverboard is installed, the next step is to connect the cables to the
board. These include the data (ribbon) cables for the peripherals and control panel
and the power cables.
Connecting Data Cables
The ribbon cables used to transfer data from the peripheral devices have been carefully routed to prevent them from blocking the fl ow of cooling air that moves through
the system from front to back. If you need to disconnect any of these cables, you
should take care to keep them routed as they were originally after reconnecting
them (make sure the red wires connect to the pin 1 locations). The following data
cables (with their locations noted) should be connected. (See the layout on page
5-12 for connector locations.)
• SATA drive data cables (I-SATA0 ~ 3)
• SATA sideband cable (T-SGPIO ~ 1)
• Control Panel cable (JF1)
• GPU power cables (JPW3, JPW7 and JPW11)
• SATA backplane power cable (JPW5)
Important! Make sure the the cables do not come into contact with the fans.
Connecting Power Cables
The X9DRG-HF/X9DRG-HTF has three proprietary power supply connectors
(JPW1, JPW2 and JPW9) for connection to the ATX power supply. See Section 5-9
for power connector pin defi nitions.
Connecting the Control Panel
JF1 contains header pins for various front control panel connectors. See Figure 5-1
for the pin locations of the various front control panel buttons and LED indicators.
All JF1 wires have been bundled into a single ribbon cable to simplify this connection. Make sure the red wire plugs into pin 1 as marked on the board. The other
end connects to the Control Panel PCB board, located just behind the system status
LEDs on the chassis. See Chapter 5 for details and pin descriptions.
5-3
Page 52
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual
Figure 5-1. Control Panel Header Pins
20 19
Ground
NMI
x (Key)
Power On LED
HDD LED
NIC1 LED (Link)
NIC2 LED (Link)
OH/Fan Fail/PWR Fail/UID LED
PWR Fail LED
Ground
Ground
2 1
x (Key)
3.3V
FP UID/3.3V Stby
NIC1 LED (Activity)
NIC2 LED (Activity)
Blue LED (UID Cathode)
3.3V
Reset (Button)
Power (Button)
5-4 I/O Ports
The I/O ports are color coded in conformance with the PC 99 specifi cation. See
Figure 5-2 below for the colors and locations of the various I/O ports.
Figure 5-2. I/O Ports
1
3
1
2
4
1
5
1
6
1
I/O Ports
1.USB Port 05.LAN Port 2
2.USB Port 16.VGA Port
3.IPMI Dedicated LAN7.UID Switch
4.LAN Port 1
1
7
5-4
Page 53
Chapter 5: Advanced Serverboard Setup
OPEN 1st
WARNING!
OPEN 1st
WARNING!
5-5 Installing the Processor and Heatsink
Warning: Avoid placing direct pressure to the top of the processor package. Always
remove the power cord fi rst before adding, removing or changing any hardware com-
ponents.
Notes:
• Always connect the power cord last and always remove it before adding, re-
moving or changing any hardware components. Make sure that you install the
processor into the CPU socket before you install the CPU heatsink.
• If you buy a CPU separately, make sure that you use an Intel-certifi ed multi-
directional heatsink only.
• Make sure to install the serverboard into the chassis before you install the CPU
heatsinks.
• When receiving a serverboard without a processor pre-installed, make sure that
the plastic CPU socket cap is in place and none of the socket pins are bent;
otherwise, contact your retailer immediately.
• Refer to the Sup ermi cro web s ite for upd ates on CPU su ppor t.
Installing an LGA 2011 Processor
Follow the procedure below, beginning
with the CPU1 socket.
1. There are two levers on the LGA
2011 socket. First press and release the load lever labeled 'Open
1st'.
2. Press the second load lever
labeled 'Close 1st' to release the
load plate from its locked position.
Press down on
Pull lever away
from the socket
the lever labeled
'Close 1st'
WARNING!
OPEN 1st
WARNING!
OPEN 1st
5-5
Page 54
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual
WARNING!
OPEN
1st
WARNING!
3. With the lever labeled 'Close 1st'
fully retracted, gently push down
on the ' Open 1st ' lever to o pen th e
load plate. Lift the load plate to
open it completely.
4. Us ing your t humb and t he ind ex
fi nger, remove the ' WAR NIN G'
plastic c ap fr om the so cket.
5. Use your thumb and index fi nger
to hold the CPU by its edges. Align
the CPU keys, which are semicircle cutouts, against the socket
keys.
6. Once they are aligned, carefully
lower the CPU straight down into
the socket. (Do not drop the CPU
on the socket. Do not move the
CPU horizontally or vertically and
do not rub the CPU against any
pins of the socket, which may
damage the CPU or the socket.)
WARNING!
OPEN 1st
Gently push
down to pop
the load plate
open.
WARNING!
Socket Keys
CPU Keys
5-6
Page 55
Chapter 5: Advanced Serverboard Setup
OPEN 1st
OPEN 1st
Warning: You can only install the CPU to the socket in one direction. Make sure that
the CPU is properly inserted into the socket before closing the load plate. If it doesn't
close properly, do not force it as it may damage your CPU. Instead, open the load
plate again and double-check that the CPU is aligned properly.
7. With the CPU in the socket, inspect the four corners of the CPU
Gently close
the load plate.
to make sure that they are fl ush
with the socket.
8. Close the load plate. Lock the
lever labeled 'Close 1st', then lock
the lever labeled 'Open 1st'. Use
your thumb to gently push the
load levers down until the lever
locks.
Push down and lock the
9. Repeat the procedure to install
level labeled 'Close 1st'.
a second processor in the CPU2
socket if desired.
Note: the PCI-E slots are controlled by
the presence of a CPU. Slots will not
be functional if the CPU that controls
them is not installed. See Section 5-7
for details.
OPEN 1st
Lever Lock
OPEN 1st
Push down
and lock the
lever labeled
'Open 1st'.
5-7
Page 56
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual
Installing a CPU Heatsink
1. Remove power from the system
and unplug the AC power cord
from the power supply.
2. Do not apply any thermal grease
to the heatsink or the CPU die;
the required amount has already
been applied.
3. Place the heatsink on top of the
CPU so that the four mounting
holes are aligned with those on
the (preinstalled) heatsink retention mechanism.
4. Screw in two diagonal screws until
just snug. Do not fully tighten the
screws or you may damage the
CPU.)
5. Add the two remaining screws
then fi nish the installation by fully
tightening all four screws.
Removing the Heatsink
SNK-P0047PS (CPU1)
SNK-P0047PSC (CPU2)
1. Unscrew and remove the heatsink screws from the serverboard in the sequence
as show in the picture above.
2. Hold the heatsink and gently wriggle the heatsink to loosen it from the CPU. (Do
not use excessive force when wriggling the heatsink!!)
3. Once the heatsink is loose, remove it from the CPU socket.
4. Clean the surface of the CPU and the heatsink to get rid of the old thermal
grease. Reapply the proper amount of thermal grease on the surface before you
re-install a heatsink.
Note: see Chapter 6 for details on installing the air shroud.
5-8
Page 57
Chapter 5: Advanced Serverboard Setup
5-6 Installing Memory
Warning: Exercise extreme care when installing or removing DIMM modules to prevent
any possible damage.
Memory Support
The X9DRG-HF/X9DRG-HTF supports up to 256 GB of registered ECC DDR31600/1333/1066/800 MHz RDIMMs in 8 DIMM slots. See the following tables for
memory installation.
Notes: Memory speed support is dependent on the type of CPU used on the board.
Installing Memory Modules
1. Insert the desired number of DIMMs into the memory slots, starting with
P1-DIMM 1A. For best memory performance, please install memory modules
of the same type and same speed on the memory slots as indicated on the
tables below.
2. Insert each DIMM module vertically into its slot. Pay attention to the notch
along the bottom of the module to avoid installing incorrectly (see Figure 5-4).
3. Gently press down on the DIMM module until it snaps into place in the slot.
Repeat for all modules.
Figure 5-3. DIMM Installation
Notch
To In st al l : Inser t module
vert ic ally a nd pre ss
down unt il it sn aps in to
place. Pay a tte ntio n to
the ali gnme nt notc h at
the bottom.
To Remove:
Use your thumbs to
gently push the release
tabs near both ends of
the module. This should
release it from the slot.
Release Tab
Note: Notch should align
with the receptive key
point on the slot.
Front View
Notch
Release Tab
Top View of DDR3 Slot
5-9
Page 58
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual
Processor/DIMM Population Confi gurations
For memor y to wor k pro perl y, follow the tab les be low for me mor y inst allati on.
• For memory to operate properly, please install DIMMs in pairs (have an even
number of DIMMs installed).
• All channels in a system will run at the fastest common frequency.
Processors and their Corresponding
DIMMs
CPU#Corresponding DIMM Modules
CPU 1P1-A1P1-B1P1-C1P1-D1
CPU2P2-E1P2-F1P2-G1P2-H1
Populating DIMMs
Number of
CPUs+DIMMs
1 CPU &
2 DIMMs
1 CPU &
4 DIMMs
2 CPUs &
4 DIMMs
CPU1
P1-A1/P1-B1
CPU1
P1-A1/P1-B1, P1-C1/P1-D1
CPU1 + CPU2
P1-A1/P1-B1, P2-E1/P2-F1
CPU and DIMM Population Confi guration Table
(For memory to work proper, please install DIMMs in pairs)
11Reg. ECC DDR3800/1066/1333/1600SR, DR, or QR
21Reg. ECC DDR3800/1066/1333/1600SR, DR, or QR
22Reg. ECC DDR3800/1066/1333/1600Mixing SR, DR, QR
Population Rules:
1. Any combination of x4 and x8 RDIMMs with 1 Gb or 2 Gb DRAM density are supported.
2. Populate DIMMs starting with DIMM A1.
3. When mixing QR with SR or DR on the same DDR channel, put the QR in DIMMA1 fi rst.
DIMMs
Popu-
lated
per DDR
Channel
RDIMM Type
(RDIMM = Regis-
tered DIMMs)
POR Speeds (in MHz)Ranks per DIMM
(Any Combination)
5-10
Page 59
Chapter 5: Advanced Serverboard Setup
5-6 Expansion Cards
In addition to offering support for three GPU cards, the 1027GR-TRF/1027GR-TRFT
supports one low-profi le PCI-Express 3.0 x8 expansion card (in x16 slot). A riser
card is required to support expansion cards.
Refer to Chapter 6 for instructions on installing an expansion card in the system..
5-11
Page 60
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual
5-7 Serverboard Details
Figure 5-5. X9DRG-HF/X9DRG-HTF Layout
Notes
Use SNK-P0047PS
Use SNK-P0047PSC
" " indicates the location of Pin 1.
The X9DRG-HTF supports two X540-based 10G LAN ports, the X9DRG-HF sup-
BatteryOnboard Battery
FAN1 - FAN4CPU Fans
FANA - FANHGPU Fans
JCOM1COM Header for Front Chassis Access
JF1Control Panel Header
JL1Chassis Intrusion Header
JOH1Overheat LED Indicator
2
JI
C1/JI2C2Power Supply SMBbus I2C Header
JPW1 Proprietary 62-pin Power Connector
JPW2Proprietary 20-pin Power Connector
JPW3-8, JPW1112V 8-pin Power Connectors
JPW9Proprietary 38-pin Power Connector
JPW105V 4-pin Power Connector
JSD1Power Fail Header
JSPK1Onboard Speaker Header
JTPM1TPM (Trusted Platform Module)/Port 80 Header
JRK1SATA RAID Key Header
JVGA1Backpanel VGA Port
LAN1/LAN2
(IPMI) LANIPMI Dedicated LAN
LAN Ports 1/2 (Gb LAN on X9DRG-HF, 10 Gb LAN on X9DRGHTF)
5-13
Page 62
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual
I-SATA 0~5SATA 3.0 (I-SATA 0/1) and SATA 2.0 Ports (I-SATA 2~5)
S-SATA 0~3SATA 2.0 Ports (S-SATA 0~3)
PCI Slot 1/Slot 2PCI-E 3.0 x16 Slots (Available when CPU1 is populated)
PCI Slot 5PCI-E 3.0 x8 in x16 Slot (Available when CPU1 is populated)
PCI Slot 3/Slot 4PCI-E 3.0 x16 Slots (Available when CPU2 is populated)
(PCH) PCI Slot 6PCI-E 2.0 x4 in x8 Slot (Available when CPU2 is populated)
SW1UID Switch
T-SGPIO 1/2/SSerial Link General Purpose I/O Headers
USB 0/1Back Panel USB Ports
LEDDescriptionState/Status
DM1BMC Heartbeat LEDGreen: BMC Normal
LE1Standby PWR L EDGreen: SB Power On
LE4UID Switch LED
Notes:
PCI-E Slot 1, Slot 2 and Slot 5 are controlled by CPU1 and are only available when a
processor is installed in CPU Socket 1. PCI-E Slot 3, Slot 4 and Slot 6 are controlled
by CPU2 and are available only when a processor is installed in CPU Socket 2.
To provide adequate power supply to the system, be sure to connect all onboard
power connectors to the power supply.
5-14
Page 63
5-8 Connector Defi nitions
Chapter 5: Advanced Serverboard Setup
Power Connectors
Three SMC-proprietary power connectors
are located at JPW1, JPW2 and JPW9 to
provide main power to the serverboard.
Seven 12V, 8-pin power connectors, located at JPW3-8 and JPW11, are used
for SATA devices and GPU cards (JPW5
is for the backplane). An additional 4-pin
auxilliary connector is located at JPW10.
Connect these power headers as described below.
JPW3, 4, 6, 7, 8, 11: 12V 8-pin for GPU power
JPW10: 5V 4-pin Auxilliary
Power Button Connector
The PW_ON connector is on pins 1 and 2
of JF1. Momentarily contacting both pins
will power on/off the system. This button
can also be confi gured to function as a
suspend button (with a setting in the BIOS,
see Chapter 7). To turn off the power when
set to suspend mode, press the button for
at least 4 seconds. Refer to the table on
the right for pin defi nitions. This header
should be connected to the chassis power
button. See the table on the right for pin
defi nitions.
Power Button
Pin Defi nitions (JF1)
Pin# Defi nition
1Power Button
2Ground
5-15
Page 64
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual
Reset Connector
The reset connector is located on pins 3
and 4 of JF1 and attaches to the reset
switch on the computer chassis. See the
table on the right for pin defi nitions.
Power Fail LED
The Power Fail LED connection is located
on pins 5 an d 6 of JF1. Refer to the tabl e
on the r ight for p in defi nitions.
Overheat/Fan Fail/UID LED
Conne ct an LED c able to pin s 7 and 8 of
JF1 for the Overheat/Fan Fail and UID
LED connections. The red LED (pin 8)
provides warning of an overheat or fan
failure. T h e bl ue LE D (pi n 7) wo r ks a s th e
UID LED in dica tor for t he fro nt pane l UID
button located on pins 13~14 of JF1. When
Jumper J_UID_OW is set to off (default),
the red LED takes precedence over the
blue LED. Refer to t he tab les on t he ri ght
for more in format ion.
Reset Button
Pin Defi nitions (JF1)
Pin# Defi nition
3Reset
4Ground
PWR Fail LED
Pin Defi nitions (JF1)
Pin# Defi nition
53.3V
6PWR Fail LED
OH/Fan Fail/Blue_UID LED Pin
Defi nitions (JF1)
Pin# Defi nition
7Blue_LED-Cathode(UID)/5.5V.SB
8OH/Fan Fail/UID LED (Red)
OH/Fan Fail LED Status
(Red LED)
State Defi nition
OffNormal
OnOverheat
FlashingFan Fail
NIC2 (LAN2) LED
The LED connections for LAN2 are on pins
9 and 10 of JF1. Attach an LED cable to
display network activity. See the table on
the right for pin defi nitions.
NIC1 (LAN1) LED
The LED connections for LAN1 are on pins
11 and 12 of JF1. Attach an LED cable to
display network activity. See the table on
the right for pin defi nitions.
NIC2 LED
Pin Defi nitions (JF1)
Pin# Defi nition
9Activity LED
10Link LED
NIC1 LED
Pin Defi nitions (JF1)
Pin# Defi nition
11Activity LED
12Link LED
5-16
Page 65
Chapter 5: Advanced Serverboard Setup
HDD/FP UID Button
The HDD/UID button connections are
located on pins 13/14 of JF1. Attach a
hard-drive LED cable to display HDD or
SATA activity. This connection can also be
used for the front panel UID (Unit Identifi er) button. (The UID LED on pin 7 of JF1
works in conjunction with the UID button.)
When the user presses and releases the
UID button, the UID LED will be turned on
or off to indicate the location of the unit in
a stack or rackmounted servers.
Power On LED
The Power On LED connector is located
on pins 15 and 16 of JF1. This connection
is used to provide LED indication of power
being supplied to the system. See the table
on the right for pin defi nitions.
HDD/UID LED
Pin Defi nitions (JF1)
Pin# Defi nition
13UID Signal/3.3V
14HDD Activity
Power LED
Pin Defi nitions (JF1)
Pin# Defi nition
15+3.3V
16Control
Fan Headers
The X9DRG-HF/X9DRG-HTF has twelve
fan headers. Fans 1~4 are for CPU/system
use and Fans A~H for GPU use.. All are
4-pin fan headers, which are backward
compatible with traditional 3-pin fans.
However, fan speed control is available for
4-pin fans only. See the table on the right
for pin defi nitions.
Serial Ports
A COM Port (COM1) is located next to
the UID s witch to p rovide se rial p ort s upport. See the table on the right for pin
defi nitions.
The non-maskable interrupt header is located at JNMI1. Refer to the table on the
right for pin defi nitions.
Internal Buzzer
The Speaker header, located at JSPK1,
can be used to provide audible alarms for
various beep codes. See the table on the
right for pin defi nitions.
Chassis Intrusion
A Chassis Intrusion header is located at
JL1 on the serverboard. Attach an appropriate cable from the chassis to inform
you of a chassis intrusion when the chassis
is opened.
Three SGPIO (Serial-Link General Purpose Input/Output) headers are provided
on the serverboard. These headers support serial link interfaces for the onboard
SATA ports. See the table on the right for
pin defi nitions.
RAIDKey Header
A RAIDKey header (JRK1) provides
RAID function support to enhance system performance.
A Trusted Platform Module/Port 80 header
is located at JTPM1 to provide TPM and
Port 80 support, which will enhance system
performance and data security. See the
table on the right for pin defi nitions.
Two Universal Serial Bus ports (USB0/1)
are located on the I/O backplane. Connect
USB devices to these ports.
Ethernet Ports
Two Ethernet ports are located next to the
USB 0/1 on the IO backplane. In addition,
an IPMI Dedicated LAN is located above
the USB ports 0/1. These ports accept
RJ45 type cables. Please refer to the LED
Indicator Section for LAN LED information
Note: The X9DRG-HF features two Gb
LAN ports while the X9DRG-HTF features
two 10 Gb LAN ports.
A Unit Identifi er (UID) switch and two LED
indicators are provided on the serverboard.
The rear UID LED (LE4) is located next
to the rear UID switch. The front panel
UID LED is on pins 7/8 of JF1. Connect
a cable to pins 7/8 on JF1 for front panel
UID indication. Pressing the UID switch will
turn on both the rear and front UID LEDs.
Pressing the UID switch again will turn
off both LEDs. These UIDs provide easy
identifi cation of a system unit that may be
in need of service.
Note: the UID can also be triggered via
IPMI. Please refer to the IPMI User's Guide
posted on our Website.
Color/State OS Status
Blue:
On
Blue:
Blinking
Pin# Defi nition
1Button In
2Ground
3Ground
4Ground
UID LED (LE4)
Status
Windows OSUnit Identifi ed
Linux OSUnit Identifi ed
UID Switch
Overheat LED/Fan Fail
The JOH1 header is used to connect an
LED indicator to provide warnings of chassis overh eating and f an failure. T his LED
will bli nk when a f an fail ure oc cur s. Refer
to the ta bles on r ight fo r pin de fi nitions.
Power SMB (I2C) Connectors
Power System Management Bus (I
Connectors (JI
2
C1/JI2C2) monitor power
2
C)
supply, fan and system temperatures. See
the table on the right for pin defi nitions.
Overheat LED
Pin Defi nitions
Pin# Defi nition
15vDC
2OH Active
OH/Fan Fail LED
Status
State Message
SolidOverheat
BlinkingFan Fail
PWR SMB
Pin Defi nitions
Pin# Defi nition
1Clock
2Data
3PWR Fail
4Ground
5+3.3V
5-20
Page 69
5-9 Jumper Settings
Explanation of Jumpers
To modify the operation of the
serverboard, jumpers can be used
to choose between optional settings.
Jumpers create shorts between two
pins to change the function of the connector. Pin 1 is identifi ed with a square
solder pad on the printed circuit board.
See the serverboard layout pages for
jumper locations.
Note: On a two-pin jumper, "Closed"
means the jumper is on both pins and
"Open" means the jumper is either on
only one pin or completely removed.
Chapter 5: Advanced Serverboard Setup
3 2 1
Connector
Pins
Jumper
3 2 1
Setting
CMOS Clear
JBT1 is used to clear CMOS (which will also clear any passwords). Instead of pins,
this jumper consists of contact pads to prevent accidentally clearing the contents
of CMOS.
To clear CMOS,
1. First power down the system and unplug the power cord(s).
2. With the power disconnected, short the CMOS pads with a metal object such
as a small screwdriver.
3. Remove the screwdriver (or shorting device).
4. Reconnect the power cord(s) and power on the system.
Note: Do not use the PW_ON connector to clear CMOS.
VGA Enable/Disable
JPG1 allows you to enable or disable the
VGA port. The default position is on pins
1 and 2 to enable VGA. See the table on
the right for jumper settings.
Change the setting of jumper JPL1 to enable or disable the LAN1/LAN2 Ethernet
ports on the serverboard. See the table on
the right for jumper settings. The default
setting is enabled.
Watch Dog Enable/Disable
JWD controls the Watch Dog function.
Watch Dog is a system monitor that can
reboot the system when a software application hangs. Jumping pins 1-2 (default)
will cause WD to reset the system if an
application hangs. Jumping pins 2-3 will
generate a non-maskable interrupt signal
for the application that hangs. See the
table on the right for jumper settings.
Watch Dog must also be enabled in BIOS.
write their own application software in order
to disable the Watch Dog Timer.
Manufacturer Mode Select
Close jumper JPME1 to bypass SPI fl ash
security and force the system to use the
Manufacturer Mode, which will allow the
user to fl ash the system fi rmware from a
host server to modify system settings. See
the table on the right for jumper settings.
Write Protect Enable
Close pins 1/2 of jumper JWP1 to enable
Write Protect support for system security
and data integrity. See the table on the
right for jumper settings.
Use jumper JPB1 to enable or disable the
BMC (Baseboard Management Controller),
which supports IPMI 2.0/KVM. See the
table on the right for jumper settings.
5-10 Onboard Indicators
LAN1/2 Port LEDs
The Ethernet ports have two LEDs. On
each port, one LED indicates activity while
the other LED may be green, amber or
off to indicate the speed of the connection. See the table on the right for the
functions associated with the connection
speed LED.
BMC Enable/Disable
Jumper Settings
Both Jumpers Defi nition
Pins 1-2Enabled
Pins 2-3Disabled
LAN Port LEDs
(Connection Speed Indicator)
LED Color 1 Gb Ports10 Gb Ports
OffNC or 10 Mb/s10/100 Mb/Off
Green100 Mb/s10 Gb/s
Amber1 Gb/s1 Gb/s
Note: the dedicated IPMI LAN does not
operate at 1 Gb/s.
Dedicated IPMI LAN Port LEDs
A dedicated IPMI LAN port is also located
on the I/O backplane. The amber LE D on
the right indicates activity, while the green
LED on the l ef t i ndi c ates t he s pe ed o f th e
connection. Please no te that the IPMI LAN
does not support 1Gbps connections. See
the tab le at right f or more i nform ation.
Onboard Power LED
An Onboard Power LED is located at
LE1. This LED Indicator is on when the
system is on. Be sure to unplug the AC
power cable before removing or adding any
components. See the table on the right for
more details.
JBR1 is used for ME Firmware Recovery
mode, which will limit system resource
for essential function use only without
putting restrictions on power use. In the
single operation mode, online upgrade
will be available via Recovery mode. See
the table on the right for jumper settings.
BMC Heartbeat LED
The BMC Heartbeat LED is designated
DM1. When DM1 is blinking, the BMC
(Baseboard Management Controller) is
functioning normally. See the table at right
for more in format ion.
The rear UID LED is located at LE4 on the
backplane. This LED is used in conjunction with the rear UID switch to provide
easy identifi cation of a system that might
be in need of service.
5-11 SATA Ports
SATA Ports
Two SATA 3.0 ports (I-SATA0 and ISAT A 1 ) and eight SAT A 2.0 ports (I-SA T A2
through I-SA T A5 and S-SA T A0 through SSATA3) are i ncluded o n the ser verboa rd.
There are no jumpers to confi gure the
onboard SATA ports. See the table on the
right for pin defi nitions.
UID LED
Status
Color/State OS Status
Blue: OnWindows OSUnit Identifi ed
Blue:
The Supermicro ftp site contains drivers and utilities for your system at ftp://ftp.
supermicro.com. Some of these must be installed, such as the chipset driver.
After accessing the ftp site, go into the CDR_Images directory and locate the ISO
fi le for your motherboard. Download this fi le to create a CD/DVD of the drivers and
utilities it contains. (You may also use a utility to extract the ISO fi le if preferred.)
Another option is to go to the Supermicro Website at
products/. Find the product page for your motherboard here, where you may down-
load individual drivers and utilities.
After creating a CD/DVD with the ISO fi les, insert the disk into the CD/DVD drive
on your system and the display shown in Figure 5-6 should appear.
Figure 5-6. Driver Installation Display Screen
http://www.supermicro.com/
Note: Click the icons showing a hand writing on paper to view the readme fi les
for each item. Click the computer icons to the right of these items to install each
item (from top to the bottom) one at a time. After installing each item, you must re-boot the system before moving on to the next item on the list. The bottom
icon with a CD on it allows you to view the entire contents.
5-25
Page 74
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual
SuperDoctor III
The SuperDoctor® III program is a web-based management tool that supports
remote management capability. It includes Remote and Local Management tools.
The local management is called SD III Client. The SuperDoctor III program allows
you to monitor the environment and operations of your system. SuperDoctor III
displays crucial system information such as CPU temperature, system voltages
and fan status. See the fi gures below for examples of the SuperDoctor III interface.
Note: The default User Name and Password for SuperDoctor III is ADMIN / ADMIN.
Note: When SuperDoctor III is fi rst installed, it adopts the temperature threshold
settings that have been set in BIOS. Any subsequent changes to these thresholds
must be made within SuperDoctor III, as the SuperDoctor III settings override the
BIOS settings. To set the BIOS temperature threshold settings again, you would
fi rst need to uninstall SuperDoctor III.
Figure 5-7. SuperDoctor III Interface Display Screen (Health Information)
5-26
Page 75
Chapter 5: Advanced Serverboard Setup
Figure 5-8. SuperDoctor III Interface Display Screen (Remote Control)
Note: The SuperDoctor III program and User ’s Manual can be downloaded from
the Supermicro web site at http://www.supermicro.com/products/accessories/soft-
ware/SuperDoctorIII.cfm
. For Linux, we recommend that you use the SuperDoctor
II application instead.
5-27
Page 76
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual
5-13 Onboard Battery
Care must be taken to assure that the chassis cover is in place when the system
is operating to assure proper cooling. Out of warranty damage to the system can
occur if this practice is not strictly followed.
Figure 5-9. Installing the Onboard Battery
Please handle used batteries carefully. Do not damage the battery in any way; a
damaged battery may release hazardous materials into the environment. Do not
discard a used battery in the garbage or a public landfi ll. Please comply with the
regulations set up by your local hazardous waste management agency to dispose
of your used battery properly.
5-28
Page 77
Chapter 6: Advanced Chassis Setup
Chapter 6
Advanced Chassis Setup
This chapter covers the steps required to install components and perform maintenance on the SC118GQ chassis. For component installation, follow the steps in the
order given to eliminate the most common problems encountered. If some steps
are unnecessary, skip ahead to the next step.
Tools Required:
maintenance is a Philips screwdriver.
The only tool you will need to install components and perform
6-1 Static-Sensitive Devices
Electrostatic Discharge (ESD) can damage electronic com ponents. To prevent
damage to any printed circuit boards (PCBs), it is important to handle them very
carefully.
The following measures are generally suffi cient to protect your equipment from
ESD damage.
Precautions
• Use a grounded wrist strap designed to prevent static discharge.
• Touch a grounded metal object before removing any board from its antistatic
bag.
• Handle a board by its edges only; do not touch its components, peripheral chips,
memory modules or gold contacts.
• When handling chips or modules, avoid touching their pins.
• Put the serverboard, add-on cards and peripherals back into their antistatic
bags when not in use.
• For grounding purposes, make sure your computer chassis provides excellent
conductivity between the power supply, the case, the mounting fasteners and
the serverboard.
6-1
Page 78
SUPERSERVER 1027GR-TRF/1027GR-TRFT Series User's Manual
Figure 6-1. Chassis: Front and Rear Views
GPU Card
Control Panel
Hot-Swap Drive Bays (4)
PCI Slot
Power Supplies
GPU Card
GPU CardRear I/O Ports
Note: the number of PCI slots available depends on the presence of GPUs in the
server model.
6-2 Control Panel
The control panel (located on the front of the chassis) must be connected to the
JF1 connector on the serverboard to provide you with system status indications. A
ribbon cable has bundled these wires together to simplify the connection. Connect
the cable from JF1 on the serverboard to the appropriate header on the Control
Panel PCB (printed circuit board). Make sure the red wire plugs into pin 1 on both
connectors. Pull all excess cabling out of the airfl ow path.
The control panel LEDs inform you of system status. See "Chapter 3: System Interface" for details on the LEDs and the control panel buttons. Details on JF1 can
be found in "Chapter 5: Advanced Serverboard Installation."
6-3 System Cooling
Ten 4-cm counter-rotating fans provide the cooling for the system. Each fan unit
is actually made up of two fans joined back-to-back, which rotate in opposite directions. This counter-rotating action generates exceptional airfl ow and works to
dampen vibration levels.
It is very important that the chassis top cover is properly installed and making a
good seal in order for the cooling air to circulate properly through the chassis and
cool the components.
6-2
Page 79
Chapter 6: Advanced Chassis Setup
System Fan Failure
Fan speed is controlled by system temperature via a BIOS setting. If a fan fails, the
remaining fans will ramp up to full speed. Replace any failed fan at your earliest
convenience with the same type and model (the system can continue to run with a
failed fan). Failed fans can be identifi ed through the BIOS. (See the fan numbering
in Figure 6-3. These numbers are also imprinted on the fl oor of the chassis.)
Replacing a System Fan
1. If the BIOS is not being utilized to determine which fan has failed, open the
top cover of the chassis while the system is running to locate the position of
the failed fan. Never run the server for an extended period of time with the
top cover open.
2. Turn off the power to the system and unplug the AC power cord.
3. Remove the failed fan's wiring from the serverboard.
4. Remove the four pins securing the fan to the fan tray.
5. Lift the failed fan from the fan tray and out of the chassis.
6. Place the new fan into the vacant space in the fan tray, while making sure the
arrows on the top of the fan (indicating air direction) point in the same direction as the arrows on the other fans in the same fan tray.
7. Reconnect the fan wires to the exact same chassis fan headers as the previous fan.
8. Reconnect the AC power cord, power up the system and check that the fan is
working properly before replacing the chassis cover.
Figure 6-2. Removing a Fan from the Fan Tray
6-3
Page 80
SUPERSERVER 1027GR-TRF/1027GR-TRFT Series User's Manual
Figure 6-3. Installing a Fan
Figure 6-4. Installing the Air Shroud
Installing the Air Shroud
Air shrouds concentrate airfl ow to maximize fan effi ciency. The SC118GQ chassis
air shroud does not require screws to set up. Note that each GPU card has its
own air shroud.
Installing the Air Shroud
1. Position the air shroud in the chassis as illustrated in Figure 6-4.
6-4
Page 81
Chapter 6: Advanced Chassis Setup
2. Align the notch on the air shroud with the pin on the add-on card bracket.
3. Slide the pin into the back of the notch.
4. Lower the front of the air shroud over the fan tray, sliding the front notches
over the pins on the fan tray.
Installing Graphics (GPU) Cards
The system supports three GPU cards, which are mounted in brackets to fi t into
the PCI-E 3.0 slots at the front of the chassis. NVIDIA Fermi M2090, Fermi M2075
and NVIDIA Kepler K10 GPUs are supported. The GPU cards may be preinstalled,
the procedure below is provided for when a GPU card needs to be replaced. See
NVIDIA's web site for more details on the K10 GPU specifi cations.
Installing Graphics Cards
1. Identify the left and right brackets and graphics cards as illustrated below.
2. Insert the graphics cards into the brackets, aligning the mounting holes in the
cards with those in the brackets. Kepler cards require a different bracket than
Fermi cards (MCP-240-00117-0N). The system comes with Fermi brackets already installed by default. If replacing Fermi GPUs with Kepler GPUs, remove
the Fermi brackets from the chassis and replace with the Kepler brackets.
3. Secure each card to the bracket using the screws that are included for this
purpose. Keplers: remove the bracket on the end of the GPU, add a washer
(included in kit) between the plate and the pcb for each screw, then attach the
GPU to the system Kepler bracket (MCP-240-00117-0N), which now takes the
place of the Fermi bracket.
4. Carefullly position each bracket in the chassis as illustrated below, aligning
the four mounting holes in the top and side of each bracket with the corresponding mounting holes in the chassis. Pay attention to the airfl ow arrows
to install each card into the correct side of the chassis
5. Secure the bracket to the chassis by using the screws provided.
6. After a GPU card is installed, you must connect it to one of the following
power headers on the serverboard: JPW3, JPW4, JPW6, JPW7, JPW8 or
JPW11.
6-5
Page 82
SUPERSERVER 1027GR-TRF/1027GR-TRFT Series User's Manual
Figure 6-5. Installing GPU Cards into the Left and Right GPU Brackets
Airfl ow
1
2
Left Side GPU Bracket
and Cards
Arrows indicate
direction of airfl ow
Right Side GPU Bracket
and Cards
Important Note for Kepler GPUs: note the airfl ow arrows on top of the GPU card.
The card with the arrow pointing toward the Tesla logo should go on the left side of
the chassis, and the card with the arrow pointing away from the Tesla logo should
go on the right side of the chassis (when viewed from the front of the system).
The Kepler GPU card brackets need two additional washers added (see note on
previous page).
6-6
Page 83
Chapter 6: Advanced Chassis Setup
6-4 Drive Bay Installation/Removal
Accessing the Drive Bays
Because of their hotswap capability, you do not need to access the inside of the
chassis or power down the system to install or replace hard drives. Proceed to the
next section for instructions.
Hard Drive Installation
The hard drives are mounted in drive carriers to simplify their installation and
removal from the chassis. These carriers also help promote proper airfl ow for
the drive bays. For this reason, even empty carriers without drives installed must
remain in the chassis.
Removing Hard Drive Carriers from the Chassis
1. Press the release button on the drive carrier. This extends the drive carrier handle.
2. Use the handle to pull the drive carrier out of the chassis.
Installing a Hard Drive into a Drive Carrier
1. Remove the dummy drive, which comes pre-installed in the drive carrier, by
removing the screws securing the dummy drive to the carrier. Note that these
screws cannot be reused on the actual 2.5" hard drive.
2. Insert a drive into the carrier with the PCB side facing down and the connector end toward the rear of the carrier.
3. Align the drive in the carrier so that the screw holes of both line up. Note that
there are holes in the carrier marked “SATA” to aid in correct installation.
4. Secure the drive to the carrier with four M3 screws as illustrated below. These
screws are included in the chassis accessory box.
5. Insert the drive carrier into its bay, keeping the carrier oriented so that the
hard drive is on the top of the carrier and the release button is on the right
side. When the carrier reaches the rear of the bay, the release handle will
retract.
6. Push the handle in until it clicks into its locked position
Warning: Except for short periods of time (swapping hard drives), do not operate the
server with the hard drive carriers removed.
6-7
Page 84
SUPERSERVER 1027GR-TRF/1027GR-TRFT Series User's Manual
Figure 6-6. Removing a Hard Drive Carrier
1
1
Figure 6-7. Installing a Hard Drive into a Carrier
1
2
Warning: Enterprise level hard disk drives are recommended for use in Supermicro
chassis and servers. For information on recommended HDDs, visit the Supermicro
Web site at http://www.supermicro.com/products/nfo/storage.cfm
6-5 Power Supply
The 1027GR-TRF/1027GR-TRFT series server includes an 1800 watt redundant
power supply consisting of two power modules. Each power supply module has an
auto-switching capability, which enables it to automatically sense and operate at a
100V - 240V input voltage.
If either of the two power supply modules fail, the other module will take the full
load and allow the system to continue operation without interruption.
Replacement units can be ordered directly from Supermicro. The power supply
units have a hot-swap capability, meaning you can replace the failed unit without
powering down the system.
6-8
Page 85
Chapter 6: Advanced Chassis Setup
Figure 6-8. Removing the Power Supply
Removing the Power Supply
1. First unplug the AC power cord from the failed power supply module.
2. Depress the locking tab on the power supply module.
3. Use the handle to pull it straight out with the rounded handle.
Installing a New Power Supply
1. Replace the failed hot-swap unit with another identical power supply unit.
2. Push the new power supply unit into the power bay until you hear a click.
3. Secure the locking tab on the unit.
4. Finish by plugging the AC power cord back into the unit.
6-9
Page 86
SUPERSERVER 1027GR-TRF/1027GR-TRFT Series User's Manual
Notes
6-10
Page 87
Chapter 7: BIOS
Chapter 7
BIOS
7-1 Introduction
This chapter describes the AMI BIOS Setup utility for the X9DRG-HF/HTF. It also
provides the instructions on how to navigate the AMI BIOS Setup utility screens.
The AMI ROM BIOS is stored in a Flash EEPROM and can be easily updated.
Starting BIOS Setup Utility
To enter the AMI BIOS Setup utility screens, press the <Del> key while the system
is booting up.
Note: In most cases, the <Del> key is used to invoke the AMI BIOS setup
screen. There are a few cases when other keys are used, such as <F3>,
<F4>, etc.
Each main BIOS menu option is described in this manual. The Main BIOS setup
menu screen has two main frames. The left frame displays all the options that can
be confi gured. Grayed-out options cannot be confi gured. Options in blue can be
confi gured by the user. The right frame displays the key legend. Above the key
legend is an area reserved for a text message. When an option is selected in the
left frame, it is highlighted in white. Often a text message will accompany it.
Note: The AMI BIOS has default text messages built in. The manufacturer
retains the option to include, omit, or change any of these text messages.
The AMI BIOS Setup utility uses a key-based navigation system called "hot keys."
Most of the AMI BIOS setup utility "hot keys" can be used at any time during setup
navigation. These keys include <F3>, <F4>, <Enter>, <ESC>, arrow keys, etc.
Notes: Options printed in Bold are default settings.
<F3> is used to load optimal default settings. <F4> is used to save the
settings and exit the setup utility.
7-1
Page 88
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual
How To Change the Confi guration Data
The confi guration data that determines the system parameters may be changed by
entering the AMI BIOS Setup utility. This Setup utility can be accessed by pressing
<Delete> at the appropriate time during system boot.
Note: For AMI UEFI BIOS Recovery, please refer to the UEFI BIOS Recovery User Guide posted @http://www.supermicro.com/support/manuals/.
Starting the Setup Utility
Normally, the only visible Power-On Self-Test (POST) routine is the memory test.
As the memory is being tested, press the <Delete> key to enter the main menu of
the AMI BIOS Setup utility. From the main menu, you can access the other setup
screens. An AMI BIOS identifi cation string is displayed at the left bottom corner of
the screen below the copyright message.
Warning! Do not upgrade the BIOS unless your system has a BIOS-related
issue. Flashing the wrong BIOS can cause irreparable damage to the system. In no event shall the manufacturer be liable for direct, indirect, special,
incidental, or consequential damage arising from a BIOS update. If you have
to update the BIOS, do not shut down or reset the system while the BIOS
is being updated to avoid possible boot failure.
7-2 Main Setup
When you fi rst enter the AMI BIOS Setup utility , you will enter the Main setup screen.
You can always return to the Main setup screen by selecting the Main tab on the
top of the screen. The Main BIOS Setup screen is shown below.
7-2
Page 89
Chapter 7: BIOS
The AMI BIOS Main menu displays the following information:
System Date/System Time
Use this option to change the system time and date. Highlight System Time or
System Date using the arrow keys. Enter new values through the keyboard and
press <Enter>. Press the <Tab> key to move between fi elds. The date must be
entered in Day MM/DD/YY format. The time is entered in HH:MM:SS format. (Note:
The time is in the 24-hour format. For example, 5:30 P.M. appears as 17:30:00.).
Supermicro X9DRG-HF
Version
This item displays the SMC version of the BIOS ROM used in this system.
Build Date
This item displays the date that the BIOS Setup utility was built.
Memory Information
Total Memory
This displays the amount of memory that is available in the system.
7-3
Page 90
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual
7-3 Advanced Setup Confi gurations
Select the Advanced tab to access the following submenu items.
Boot Features
Quiet Boot
This feature allows the user to select bootup screen display between POST messages and the OEM logo. Select Disabled to display the POST messages. Select
Enabled to display the OEM logo instead of the normal POST messages. The options are Enabled and Disabled.
AddOn ROM Display Mode
Use this item to set the display mode for the Option ROM. Select Keep Current to
use the current AddOn ROM Display setting. Select Force BIOS to use the Option
ROM display mode set by the system BIOS. The options are Force BIOS and
Keep Current.
Bootup Num-Lock
Use this fe ature to set the Powe r-on state for t he Numloc k key. T he options a re
Of f and On.
Wait For 'F1' If Error
Selec t Enabl ed to fo rce t he system t o wait unt il the ' F1' key is pressed i f an er ror
occu rs. Th e optio ns are Di sable d and Enabled.
7-4
Page 91
Chapter 7: BIOS
Interrupt 19 Capture
Interrupt 19 is the software interrupt that handles the boot disk function. When this
item is set to Enabled, the ROM BIOS of the host adaptors will "capture" Interrupt 19
at bootup and allow the drives that are attached to these host adaptors to function
as bootable disks. If this item is set to Disabled, the ROM BIOS of the host adaptors will not capture Interrupt 19, and the drives attached to these adaptors will not
function as bootable devices. The options are Enabled and Disabled.
Power Confi guration
Watch Dog Function
If enabl ed, t he Watch D o g tim er w ill a ll ow th e syste m to re bo ot wh en it i s inac t ive
for more t han 5 minu tes. The o ption s are Enabl ed and Disabled.
Power Button Function
If this feature is set to Instant Off, the system will power off immediately as soon
as the user presses the power button. If this feature is set to 4 Seconds Override,
the system will power off when the user presses the power button for 4 seconds or
longer. The options are Instant Off and 4 Seconds Override.
Restore on AC Power Loss
Use this feature to set the power state after a power outage. Select Stay Off for the
system power to remain off after a power loss. Select Power On for the system
power to be turned on after a power loss. Select Last State to allow the system
to resume its last state before a power loss. The options are Power On, Stay Off,
and Last State.
CPU Confi guration
This submenu displays the information of the CPU as detected by the BIOS. It also
allows the user to confi guration CPU settings.
Socket 1 CPU Information/Socket 2 CPU Information
This submenu displays the following information regarding the CPUs installed
in Socket 1/ Socket 2.
• Type of CPU
• CPU Signature
• Microcode Patch
7-5
Page 92
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual
• CPU Stepping
• Maximum CPU Speed
• Minimum CPU Speed
• Processor Cores
• Intel HT (Hyper-Threading) Technology
• Intel VT-x Technology
• Intel SMX Technology
• L1 Data Cache
• L1 Code Cache
• L2 Cache
• L3 Cache
CPU Speed
This item displays the speed of the CPU installed in Socket 1/Socket 2.
64-bit
This item indicates if the CPU installed in Socket 1 or Socket 2 supports 64-bit
technology.
Clock Spread Spectrum
Select Enable to enable Clock Spectrum support, which will allow the BIOS to monitor and attempt to reduce the level of Electromagnetic Interference caused by the
components whenever needed. The options are Disabled and Enabled.
RTID (Record Types IDs)
This feature displays the total number of Record Type IDs for local and remote
pools. The options are Optimal and Alternate.
Hyper-threading
Select Enabled to support Intel Hyper-threading Technology to enhance CPU performance. The options are Enabled and Disabled.
7-6
Page 93
Chapter 7: BIOS
Active Processor Cores
Set to Enabled to use a processor's second core and above. (Please refer to Intel's
website for more information.) The options are All, 1, 2, 4 and 6.
Limit CPUID Maximum
This feature allows the user to set the maximum CPU ID value. Enable this function
to boot the legacy operating systems that cannot support processors with extended
CPUID functions. The options are Enabled and Disabled (for the Windows OS).
Execute-Disable Bit (Available if supported by the OS & the CPU)
Select Enabled to enable the Execute Disable Bit which will allow the processor
to designate areas in the system memory where an application code can execute
and where it cannot, thus preventing a worm or a virus from fl ooding illegal codes
to overwhelm the processor or damage the system during an attack. The default is
Enabled. (Refer to Intel and Microsoft Web sites for more information.)
Intel® AES-NI
Select Enable to use the Intel Advanced Encryption Standard (AES) New Instructions (NI) to ensure data security. The options are Enabled and Disabled.
MLC Streamer Prefetcher (Available when supported by the CPU)
If set to Enabled, the MLC (mid-level cache) streamer prefetcher will prefetch
streams of data and instructions from the main memory to the L2 cache to improve
CPU performance. The options are Disabled and Enabled.
MLC Spatial Prefetch (Available when supported by the CPU)
If this feature is set to Disabled, The CPU prefetches the cache line for 64 bytes.
If this feature is set to Enabled the CPU fetches both cache lines for 128 bytes as
comprised. The options are Disabled and Enabled.
DCU Streamer Prefetcher (Available when supported by the CPU)
Select Enabled to support Data Cache Unite (DCU) prefetch of L1 data to speed
up data accessing and processing in the DCU to enhance CPU performance. The
options are Disabled and Enabled.
DCU IP Prefetcher
Select Enabled for DCU (Data Cache Unit) IP Prefetcher support, which will prefetch
IP addresses to improve network connectivity and system performance. The options
are Enabled and Disabled.
7-7
Page 94
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual
Intel® Virtualization Technology (Available when supported by the CPU)
Select Enabled to support Intel Virtualization Technology, which will allow one
platf orm to r un mult iple op erati ng system s and app licat ions i n indep endent p ar titions, creating multiple "virtual" systems in one physical computer. The options
are Enabled and Disabled.
Note: If there is any change to this setting, you will need to power off and
restar t the system for the change to take effec t. Please refer to Inte l’s
website for d etaile d infor matio n.)
CPU Power Management Confi guration
This submenu allows the user to confi gure the following CPU Power Management
settings.
Power Technology
Select Energy Effi ciency to support power-saving mode. Select Custom to cus-
tomize system power settings. Select Disabled to disable power-saving settings.
The options are Disabled, Energy Effi cient, and Custom. If the option is set to
Custom, the following items will display:
EIST (Available when Power Technology is set to Custom)
EIST (Enhanced Intel SpeedStep Technology) allows the system to automatically adjust processor voltage and core frequency to reduce power
consumption and heat dissipation. The options are Disabled (GV3 Disabled),
and Enabled (GV3 Enabled). (Note: GV3 is Intel Speedstep support used
on older platforms. Please refer to Intel’s website for detailed information.)
Turbo Mode (Available when Power Technology is set to Custom)
Select Enabled to use the Turbo Mode to boost system performance. The
options are Enabled and Disabled.
C1E (Available when Power Technology is set to Custom)
Select Enabled to enable Enhanced C1 Power State to boost system performance. The options are Enabled and Disabled.
CPU C3 Report (Available when Power Technology is set to Custom)
Select Enabled to allow the BIOS to report the CPU C3 State (ACPI C2) to
the operating system. During the CPU C3 State, the CPU clock generator
is turned off. The options are Enabled and Disabled.
7-8
Page 95
Chapter 7: BIOS
CPU C6 Report (Available when Power Technology is set to Custom)
Select Enabled to allow the BIOS to report the CPU C6 State (ACPI C3) to
the operating system. During the CPU C6 State, the power to all cache is
turned off. The options are Enabled and Disabled.
CPU C7 Report (Available when Power Technology is set to Custom)
Select Enabled to allow the BIOS to report the CPU C7 State (ACPI C3) to
the operating system. CPU C7 State is a processor-specifi c low C-State.
The options are Enabled and Disabled.
Package C-State limit (Available when Power Technology is set to
Custom)
This feature allows the user to set the limit on the C-State package register.
The options are C0, C2, C6, and No Limit.
Energy/Performance Bias
This setting allows the user to adjust the fan speed based on performance (maximum cooling) or energy effi ciency (maximum energy savings). The options are
Performance, Balanced Performance, Balanced Energy, and Energy Effi cient.
Factory Long Duration Power Limit
This item displays the power limit set by the manufacturer during which long
duration power is maintained.
Long Duration Power Limit
This item displays the power limit set by the user during which long duration
power is maintained. The default setting is 0.
Factory Long Duration Maintained
This item displays the period of time set by the manufacturer during which long
duration power is maintained.
Long Duration Maintained
This item displays the period of time during which long duration power is maintained. The default setting is 0.
Recommended Short Duration Power
This item displays the short duration power settings recommended by the
manufacturer.
7-9
Page 96
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual
Short Duration Power Limit
This item displays the time period during which short duration power is maintained. The default setting is 0.
Chipset Confi guration
North Bridge
This feature allows the user to confi gure the settings for the Intel North Bridge.
Integrated IO Confi guration
Intel VT-d
Select Enabled to enable Intel Virtualization Technology support for Direct I/O
VT-d
by reporting the I/O device assignments to the VWM (Virtual Working
Memory) through the DMAR ACPI Tables. This feature offers fully-protected
I/O resource sharing across Intel platforms, providing greater reliability, security
and availability in networking and data-sharing. The options are Enabled and
Disabled.
Data Direct I/O
Select Enabled to enable Intel I/OAT (I/O Acceleration Technology), which signifi cantly reduces CPU overhead by leveraging CPU architectural improvements
and freeing the system resource for other tasks. The options are Disabled and
Enabled.
DCA Support
When set to Enabled, this feature uses Intel's DCA (Direct Cache Access)
Technology to improve data transfer effi ciency. The default is Enabled and can
not be changed.
IIO 1 PCIe Port Bifurcation Control
This submenu confi gures the following IO PCIe Port Bifurcation Control settings
for IIO 1 PCIe ports to determine how the available PCI-Express lanes to be
distributed between the PCI-Exp. Root Ports.
CPU1 Slot 5 PCI-E 3.0 x8 OPROM
This feature allows the user to set the PCI-Exp bus speed for the slot specifi ed
above. The options are Gen1 (Generation 1), Gen2 and Gen3.
7-10
Page 97
Chapter 7: BIOS
CPU1 Slot 2 PCI-E 3.0 x16 OPROM
This feature allows the user to set the PCI-Exp bus speed for the slot specifi ed
above. The options are Gen1 (Generation 1), Gen2 and Gen3.
CPU1 Slot 1 PCI-E 3.0 x16 OPROM
This feature allows the user to set the PCI-Exp bus speed for the slot specifi ed
above. The options are Gen1 (Generation 1), Gen2 and Gen3.
IIO 2 PCIe Port Bifurcation Control
This submenu confi gures the following IO PCIe Port Bifurcation Control settings
for IIO 2 PCIe ports to determine how the available PCI-Express lanes to be
distributed between the PCI-Exp. Root Ports.
CPU2 Slot 3 PCI-E 3.0 x16 OPROM
This feature allows the user to set the PCI-Exp bus speed for the slot specifi ed
above. The options are Gen1 (Generation 1), Gen2 and Gen3.
CPU2 Slot 4 PCI-E 3.0 x16 OPROM
This feature allows the user to set the PCI-Exp bus speed for the slot specifi ed
above. The options are Gen1 (Generation 1), Gen2 and Gen3.
QPI Confi guration
Current QPI Link
This item displays the current status of the QPI Link.
Current QPI Frequency
This item displays the frequency of the QPI Link.
Isoc
Select Enabled to enable Ischronous support to meet QoS (Quality of Service)
requirements. This feature is especially important for virtualization technology.
The options are Enabled and Disabled.
QPI (Quick Path Interconnect) Link Speed Mode
Use this feature to select data transfer speed for QPI Link connections. The
options are Fast and Slow.
QPI Link Frequency Select
Use this feature to select the desired QPI frequency. The options are Auto, 6.4
GT/s, 7.2 GT/s, and 8.0 GT/s.
7-11
Page 98
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual
DIMM Confi guration
This section displays the following DIMM information.
Current Memory Mode
This item displays the current memory mode.
Current Memory Speed
This item displays the current memory speed.
Mirroring
This item displays if memory mirroring is supported by the motherboard. Memory
mirroring creates a duplicate copy of the data stored in the memory to enhance
data security.
Sparing
This item displays if memory sparing is supported by the motherboard. Memory
sparing enhances system performance.
DIMM Information
CPU Socket 1 DIMM Information/ CPU Socket 2 DIMM Information
The status of the memory modules detected by the BIOS will be displayed as
detected by the BIOS.
Memory Mode
When Independent is selected, all DIMMs are available to the operating system.
When Mirroring is selected, the motherboard maintains two identical copies of all
data in memory for data backup. When Lock Step is selected, the motherboard
uses two areas of memory to run the same set of operations in parallel. The
options are Independent, Mirroring, and Lock Step.
DRAM RAPL Mode
RAPL (Running Average Power Limit) provides mechanisms to enforce power
consumption limits on supported processors The options are DRAM RAPL
MODE0 , DRAM RAPL MODE1, and Disabled.
DDR Speed
Use this feature to force a DDR3 memory module to run at a frequency other
than what is specifi ed in the specifi cation. The options are Auto, Force DDR3-
800, Force DDR3-1066, Force DDR3-1333, Force DDR3-1600 and Force SPD.
7-12
Page 99
Chapter 7: BIOS
Channel Interleaving
This feature selects from the different channel interleaving methods. The options
are Auto, 1 Way, 2 Way, 3, Way, and 4 Way.
Rank Interleaving
This feature allows the user to select a rank memory interleaving method. The
options are Auto, 1 Way, 2 Way, 4, Way, and 8 Way.
Patrol Scrub
Patrol Scrubbing is a process that allows the CPU to correct correctable memory
errors detected on a memory module and send the correction to the requestor
(the original source). When this item is set to Enabled, the IO hub will read and
write back one cache line every 16K cycles, if there is no delay caused by internal
processing. By using this method, roughly 64 GB of memory behind the IO hub
will be scrubbed every day. The options are Enabled and Disabled.
Demand Scrub
Demand Scrubbing is a process that allows the CPU to correct correctable
memory errors found on a memory module. When the CPU or I/O issues a
demand-read command, and the read data from memory turns out to be a
correctable error, the error is corrected and sent to the requestor (the original
source). Memory is updated as well. Select Enabled to use Demand Scrubbing
for ECC memory correction. The options are Enabled and Disabled.
Data Scrambling
Select Enabled to enable data scrambling to ensure data security and integrity.
The options are Disabled and Enabled.
Device Tagging
Select Enabled to support device tagging. The options are Disabled and Enabled.
Thermal Throttling
Throttling improves reliability and reduces power consumption in the processor via automatic voltage control during processor idle states. The options are
Disabled and CLTT (Closed Loop Thermal Throttling).
7-13
Page 100
SUPERSERVER 1027GR-TRF/1027GR-TRFT User's Manual
South Bridge Confi guration
This feature allows the user to confi gure the settings for the Intel PCH chip.
PCH Information
This feature displays the following PCH information.
Name: This item displays the name of the PCH chip.
Stepping: This item displays the status of the PCH stepping.
USB Devices: This item displays the USB devices detected by the BIOS.
All USB Devices
This feature enables all USB ports/devices. The options are Disabled and Enabled.
(If set to Enabled, EHCI Controller 1 and Controller 2 will appear.)
EHCI Controller 1/EHCI Controller 2 (Available when All USB Devices is set
to Enabled)
Select Enabled to enable EHCI (Enhanced Host Controller Interface) Controller 1
or Controller 2. The options are Disabled and Enabled.
Legacy USB Support (Available when USB Functions is not Disabled)
Select Enabled to support legacy USB devices. Select Auto to disable legacy support if USB devices are not present. Select Disable to have USB devices available
for EFI (Extensive Firmware Interface) applications only. The settings are Disabled,
Enabled and Auto.
Port 60/64 Emulation
Select Enabled to enable I/O port 60h/64h emulation support for the legacy USB
keyboard so that it can be fully supported by the operating systems that does not
recognize a USB device. The options are Disabled and Enabled.
EHCI Hand-Off
This item is for operating systems that do not support Enhanced Host Controller
Interface (EHCI) hand-off. When enabled, EHCI ownership change will be claimed
by the EHCI driver. The options are Disabled and Enabled.
SATA Confi guration
When this submenu is selected, the AMI BIOS automatically detects the presence
of IDE or SATA devices and displays the following items.
SATA Port0~SATA Port5: The AMI BIOS displays the status of each SATA port
as detected by the BIOS.
7-14
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.