Supero SUPERSERVER, 1027R-73DARF User Manual

Page 1
®
SUPERSERVER
1027R-73DARF
SUPER
USER’S MANUAL
Page 2
The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccuracies that may be contained in this document, makes no commitment to update or to keep current the information in this manual, or to notify any person or organization of the updates. Please Note: For the most up-to-date version of this
manual, please see our web site at www.supermicro.com.
Super Micro Computer, Inc. ("Supermicro") reserves the right to make changes to the product described in this manual at any time and without notice. This product, including software and docu­mentation, is the property of Supermicro and/or its licensors, and is supplied only under a license. Any use or reproduction of this product is not allowed, except as expressly permitted by the terms of said license.
IN NO EVENT WILL SUPERMICRO BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL, SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO USE THIS PRODUCT OR DOCUMENTATION, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. IN PARTICULAR, SUPERMICRO SHALL NOT HAVE LIABILITY FOR ANY HARDWARE, SOFTWARE, OR DATA STORED OR USED WITH THE PRODUCT, INCLUDING THE COSTS OF REPAIRING, REPLACING, INTEGRATING, INSTALLING OR RECOVERING SUCH HARDWARE, SOFTWARE, OR DATA.
Any disputes arising between manufacturer and customer shall be governed by the laws of Santa Clara County in the State of California, USA. The State of California, County of Santa Clara shall be the exclusive venue for the resolution of any such disputes. Super Micro's total liability for all claims will not exceed the price paid for the hardware product.
FCC Statement: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environ­ment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the manufacturer’s instruction manual, may cause harmful interference with radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case you will be required to correct the interference at your own expense.
California Best Management Practices Regulations for Perchlorate Materials: This Perchlorate warn­ing applies only to products containing CR (Manganese Dioxide) Lithium coin cells. “Perchlorate Material-special handling may apply. See www.dtsc.ca.gov/hazardouswaste/perchlorate”
WARNING: Handling of lead solder materials used in this product may expose you to lead, a chemical known to the State of California to cause birth defects and other repro­ductive harm.
Manual Revision 1.0 Release Date: September 24, 2012
Unless you request and receive written permission from Super Micro Computer, Inc., you may not copy any part of this document.
Information in this document is subject to change without notice. Other products and companies referred to herein are trademarks or registered trademarks of their respective companies or mark holders.
Copyright © 2012 by Super Micro Computer, Inc. All rights reserved.
Printed in the United States of America
Page 3
iii
Preface
Preface
About This Manual
This manual is written for professional system integrators and PC technicians. It
provides information for the installation and use of the SuperServer 1027R-73DARF.
Installation and maintainance should be performed by experienced technicians only.
The SuperServer 1027R-73DARF is a high-end server based on the SC113TQ-
R700CB 1U rackmountable chassis and the X9DRD-7LN4F dual processor
serverboard.
Manual Organization
Chapter 1: Introduction
The rst chapter provides a checklist of the main components included with the
server system and describes the main features of the X9DRD-7LN4F serverboard
and the SC113TQ-R700CB chassis.
Chapter 2: Server Installation
This chapter describes the steps necessary to install the SuperServer 1027R-
73DARF into a rack and check out the server conguration prior to powering up the
system. If your server was ordered without processor and memory components, this
chapter will refer you to the appropriate sections of the manual for their installation.
Chapter 3: System Interface
Refer here for details on the system interface, which includes the functions and
information provided by the control panel on the chassis as well as other LEDs
located throughout the system.
Chapter 4: System Safety
You should thoroughly familiarize yourself with this chapter for a general overview
of safety precautions that should be followed when installing and servicing the
SuperServer 1027R-73DARF.
Page 4
SUPERSERVER 1027R-73DARF User's Manual
iv
Chapter 5: Advanced Serverboard Setup
Chapter 5 provides detailed information on the X9DRD-7LN4F serverboard, in-
cluding the locations and functions of connections, headers and jumpers. Refer
to this chapter when adding or removing processors or main memory and when
reconguring the serverboard.
Chapter 6: Advanced Chassis Setup
Refer to Chapter 6 for detailed information on the SC113TQ-R700CB server chassis.
You should follow the procedures given in this chapter when installing, removing
or reconguring SAS/SATA or peripheral drives and when replacing system power
supply units and cooling fans.
Chapter 7: BIOS
The BIOS chapter includes an introduction to BIOS and provides detailed informa-
tion on running the CMOS Setup Utility.
Appendix A: BIOS Error Beep Codes
Appendix B: System Specications
Page 5
Notes
Preface
v
Page 6
vi
Table of Contents
Chapter 1 Introduction
1-1 Overview ......................................................................................................... 1-1
1-2 Serverboard Features ..................................................................................... 1-2
Processors ...................................................................................................... 1-2
Memory ........................................................................................................... 1-2
SAS ................................................................................................................. 1-2
Serial ATA ........................................................................................................ 1-2
PCI Expansion Slots ....................................................................................... 1-2
Rear I/O Ports ................................................................................................. 1-3
1-3 Server Chassis Features ................................................................................ 1-3
System Power ................................................................................................. 1-3
Control Panel .................................................................................................. 1-3
Cooling System ............................................................................................... 1-3
1-4 Contacting Supermicro .................................................................................... 1-5
Chapter 2 Server Installation
2-1 Overview ......................................................................................................... 2-1
2-2 Unpacking the System .................................................................................... 2-1
2-3 Preparing for Setup ......................................................................................... 2-1
Choosing a Setup Location ............................................................................. 2-1
Rack Precautions ............................................................................................ 2-2
Server Precautions .......................................................................................... 2-2
Rack Mounting Considerations ....................................................................... 2-3
Ambient Operating Temperature ................................................................ 2-3
Reduced Airow ......................................................................................... 2-3
Mechanical Loading ................................................................................... 2-3
Circuit Overloading ..................................................................................... 2-3
Reliable Ground ......................................................................................... 2-3
2-4 Installing the System into a Rack ................................................................... 2-4
Identifying the Sections of the Rack Rails ...................................................... 2-4
Inner Rails ....................................................................................................... 2-5
Outer Rails ...................................................................................................... 2-6
Installing the Server into a Telco Rack ........................................................... 2-9
Chapter 3 System Interface
3-1 Overview ......................................................................................................... 3-1
3-2 Control Panel Buttons ..................................................................................... 3-1
Reset ............................................................................................................... 3-1
Power .............................................................................................................. 3-1
SUPERSERVER 1027R-73DARF User's Manual
Page 7
vii
UID .................................................................................................................. 3-1
3-3 Control Panel LEDs ........................................................................................ 3-2
Information LED .............................................................................................. 3-2
NIC1 ................................................................................................................ 3-3
NIC2 ................................................................................................................ 3-3
HDD ................................................................................................................. 3-3
Power .............................................................................................................. 3-3
3-4 Hard Drive Carrier LEDs ................................................................................. 3-4
Chapter 4 System Safety
4-1 Electrical Safety Precautions .......................................................................... 4-1
4-2 General Safety Precautions ............................................................................ 4-2
4-3 ESD Precautions ............................................................................................. 4-3
4-4 Operating Precautions .................................................................................... 4-4
Chapter 5 Advanced Serverboard Setup
5-1 Handling the Serverboard ............................................................................... 5-1
Precautions ..................................................................................................... 5-1
Unpacking ....................................................................................................... 5-1
5-2 Connecting Cables .......................................................................................... 5-2
Connecting Data Cables ................................................................................. 5-2
Connecting Power Cables .............................................................................. 5-2
Connecting the Control Panel ......................................................................... 5-2
5-3 Rear I/O Ports ................................................................................................. 5-3
5-4 Installing the Processor and Heatsink ............................................................ 5-4
Installing an LGA 2011 Processor ................................................................... 5-4
Installing a Passive CPU Heatsink ................................................................. 5-7
Removing the Heatsink ................................................................................... 5-7
5-5 Installing Memory ............................................................................................ 5-8
Memory Support .............................................................................................. 5-8
DIMM Installation ............................................................................................ 5-8
5-6 Adding PCI Add-On Cards ............................................................................ 5-12
5-7 Serverboard Details ...................................................................................... 5-13
X9DRD-7LN4F Quick Reference .................................................................. 5-14
5-8 Connector Denitions ................................................................................... 5-16
5-9 Jumper Settings ............................................................................................ 5-23
5-10 Onboard Indicators ........................................................................................ 5-25
5-11 SATA and SAS Ports ..................................................................................... 5-26
5-12 Installing Software ......................................................................................... 5-27
SuperDoctor III .............................................................................................. 5-28
Table of Contents
Page 8
viii
SUPERSERVER 1027R-73DARF User's Manual
Chapter 6 Advanced Chassis Setup
6-1 Static-Sensitive Devices .................................................................................. 6-1
Precautions ..................................................................................................... 6-1
6-2 Control Panel .................................................................................................. 6-2
6-3 System Cooling ............................................................................................... 6-2
System Fan Failure ......................................................................................... 6-2
6-4 Drive Bay Installation/Removal ....................................................................... 6-4
Accessing the Drive Bays ............................................................................... 6-4
Hard Drive Installation ..................................................................................... 6-4
DVD Drive Installation ..................................................................................... 6-6
6-5 Power Supply .................................................................................................. 6-8
Chapter 7 BIOS
7-1 Introduction ...................................................................................................... 7-1
Starting BIOS Setup Utility .............................................................................. 7-1
How To Change the Conguration Data ......................................................... 7-2
Starting the Setup Utility ................................................................................. 7-2
7-2 Main Setup ...................................................................................................... 7-2
7-3 Advanced Setup Congurations...................................................................... 7-4
7-4 Event Logs .................................................................................................... 7-25
7-5 IPMI ............................................................................................................... 7-27
7-6 Boot ............................................................................................................... 7-29
7-7 Security ......................................................................................................... 7- 3 0
7-8 Save & Exit ................................................................................................... 7-31
Appendix A BIOS Error Beep Codes
Appendix B System Specications
Page 9
Chapter 1
Introduction
1-1 Overview
The SuperServer 1027R-73DARF is a high-end server comprised of two main
subsystems: the SC113TQ-R700CB 1U server chassis and the X9DRD-7LN4F dual
processor serverboard. Please refer to our web site for information on operating
systems that have been certied for use with the system (www.supermicro.com).
In addition to the serverboard and chassis, various hardware components have
been included with the 1027R-73DARF, as listed below:
•Six 4-cm counter-rotating fans (FAN-0086L4)
•Two passive CPU heatsinks (SNK-P0047PS)
•One air shroud (MCP-310-19010-0N)
•One riser card (RSC-RR1U-E8)
•SATA Accessories
One SATA backplane (BPN-SAS-113TQ)
Eight drive carriers (MCP-220-00047-0B)
•One rackmount kit (MCP-290-00043-0N)
•One CD containing drivers and utilities
•SuperServer 1027R-73DARF User's Manual
Chapter 1: Introduction
1-1
Page 10
1-2
SUPERSERVER 1027R-73DARF User's Manual
1-2 Serverboard Features
At the heart of the SuperServer 1027R-73DARF lies the X9DRD-7LN4F, a dual
processor serverboard based on the Intel C602J chipset and designed to provide
maximum performance. Below are the main features of the X9DRD-7LN4F. (See
Figure 1-1 for a block diagram of the chipset).
Processors
The X9DRD-7LN4F supports single or dual Intel® Xeon E5-2600 Series processors
in LGA 2011 sockets (Socket R). Please refer to the serverboard description pages
on our web site for a complete listing of supported processors (www.supermicro.
com).
Memory
The X9DRD-7LN4F has 16 DIMM slots that can support up to 512 GB of RDIMM,
ECC LRDIMM or ECC/non-ECC UDIMM DDR3-1600/1333/1066/800 type memory.
See Chapter 5 for details.
SAS
A total of eight SAS 2.0 ports are provided with an LSI 2308 SAS controller. RAID
levels 0, 1, and 10 are supported.
Note: The operating system you use must have RAID support to enable the hot-
swap capability and RAID function of the SAS drives.
Serial ATA
A SATA controller is also integrated into the chipset to provide two SATA 3.0 (6/
Gbps) and four SATA 2.0 (3 Gbps) ports, which are RAID 0, 1, 5 and 10 supported.
The SATA drives are hot-swappable units.
Note: The operating system you use must have RAID support to enable the hot-
swap capability and RAID function of the SATA drives.
PCI Expansion Slots
The X9DRD-7LN4F has six PCI-E 3.0 x8 slots. One PCI slot may be used with the
riser card provided with the system. PCI slots are controlled by CPUs: both CPUs
must be installed to utilize all slots. See Chapter 5 for details.
Page 11
1-3
Chapter 1: Introduction
Rear I/O Ports
The color-coded I/O ports include one COM port, a VGA port, four USB 2.0 ports
(additional USB headers are included on the serverboard) and four 1 Gb Ethernet
ports. A dedicated IPMI LAN port is also included.
1-3 Server Chassis Features
The 1027R-73DARF features eight 2.5" hard drive bays and a redundant, high-
efciency power supply. Details on the chassis and on servicing procedures can
be found in Chapter 6. The following is a general outline of the main features of
the chassis.
System Power
The 1027R-73DARF features a redundant 700W-750W power supply consisting of
two power modules. The system does not need to be shut down when replacing or
removing a single power supply module.
Control Panel
The control panel provides important system monitoring and control information.
LEDs indicate power on, network activity, hard disk drive activity and a UID (Uni-
versal Information) LED. Also present are a main power button, a system reset
button and a UID button.
Cooling System
The 1027R-73DARF chassis' revolutionary cooling design has been optimized to
provide sufcient cooling for dual CPU congurations. The chassis includes an air
shroud and six 4-cm counter-rotating fans located in the middle of the chassis.
System fan speed is based on temperature and controlled by IPMI.
Page 12
1-4
SUPERSERVER 1027R-73DARF User's Manual
Figure 1-1. Intel C602J Chipset:
System Block Diagram
Note: This is a general block diagram. Please see Chapter 5 for details.
CPU1
DDR3
QPI
8G
3.0 Gb/S
3.0 Gb/S
6.0 Gb/S
#3A/B
#3C/D #1B #1AP1DMI
PEG0DMI
SAS [0:3]
SATA [2:5]
SATA [0:1]
USB [0:7]
USB [9,10] LPC
SAS [4:7]
PCI
UplinkDMI
4GB/sPCI-E
X4 G3
#2~#5
#0~#1
SPI
SAS I-PASS
SAS
MUX
COM1 External
COM2 Header
MUX
BMC WPCM450
RJ45
I-PASS
GLAN I350-AM2
PCH
SSB-A/D
PCI-E X8 G3
PCI-E X8 G3
PCI-E X8 G3
PCI-E X8 G3
PCI-E X4 G3
CPU2
DDR3
#1A/B #3C/D
P1
3.0 Gb/S
RJ45
RJ45
SPI
SPI
VGA
RTL8201F
TPM Header
DDR2 RAM
SPI PCIUSB
LPC
Serial PortRMII
RMII
DDR
CRT
#C-2
#C-1
#B-2
#B-1
#A-2
#A-1
DDR3
PCI-E X16
SLOT 2
LOWER
PCI-E X16
SLOT 2
UPPER
PCI-E X8
in x4 Slot
SLOT 3
PCI-E X8
SLOT 1
800/1066/1333/1600
#F-2
#F-1
#E-2
#E-1
#D-2
#D-1
DDR3
800/1066/1333/1600
I-SATA
I-SATA
REAR
HDR 2X5
REAR
4,52,3
TYPE-A6TYPE-A
7
port 0,1
Page 13
1-5
Chapter 1: Introduction
1-4 Contacting Supermicro
Headquarters
Address: Super Micro Computer, Inc.
980 Rock Ave.
San Jose, CA 95131 U.S.A.
Tel: +1 (408) 503-8000
Fax: +1 (408) 503-8008
Email: marketing@supermicro.com (General Information)
support@supermicro.com (Technical Support)
Web Site: www.supermicro.com
Europe
Address: Super Micro Computer B.V.
Het Sterrenbeeld 28, 5215 ML
's-Hertogenbosch, The Netherlands
Tel: +31 (0) 73-6400390
Fax: +31 (0) 73-6416525
Email: sales@supermicro.nl (General Information)
support@supermicro.nl (Technical Support)
rma@supermicro.nl (Customer Support)
Asia-Pacic
Address: Super Micro Computer, Inc.
4F, No. 232-1, Liancheng Rd.
Chung-Ho Dist., New Taipei City 235
Taiwan
Tel: +886-(2) 8226-3990
Fax: +886-(2) 8226-3991
Web Site: www.supermicro.com.tw
Technical Support:
Email: support@supermicro.com.tw
Tel: 886-2-8228-1366, ext.132 or 139
Page 14
1-6
SUPERSERVER 1027R-73DARF User's Manual
Notes
Page 15
Chapter 2: Server Installation
2-1
Chapter 2
Server Installation
2-1 Overview
This chapter provides a quick setup checklist to get your SuperServer 1027R-
73DARF up and running. Following these steps in the order given should enable
you to have the system operational within a minimum amount of time. This quick
setup assumes that server system has come to you with the processors and memory
preinstalled. If your system is not already fully integrated with a serverboard, pro-
cessors, system memory etc., please turn to the chapter or section noted in each
step for details on installing specic components.
2-2 Unpacking the System
You should inspect the box the SuperServer 1027R-73DARF was shipped in and
note if it was damaged in any way. If the server itself shows damage you should
le a damage claim with the carrier who delivered it.
Decide on a suitable location for the rack unit that will hold the server. It should
be situated in a clean, dust-free area that is well ventilated. Avoid areas where
heat, electrical noise and electromagnetic elds are generated. You will also need
it placed near a grounded power outlet. Read the Rack and Server Precautions in
the next section.
2-3 Preparing for Setup
The box the SuperServer 1027R-73DARF was shipped in should include two sets of
rail assemblies, two rail mounting brackets and the mounting screws you will need to
install the system into the rack. Follow the steps in the order given to complete the
installation process in a minimum amount of time. Please read this section in its en-
tirety before you begin the installation procedure outlined in the sections that follow.
Choosing a Setup Location
•Leave enough clearance in front of the rack to enable you to open the front door
completely (~25 inches) and approximately 30 inches of clearance in the back
of the rack to allow for sufcient airow and ease in servicing.This product is for
installation only in a Restricted Access Location (dedicated equipment rooms,
service closets and the like).
Page 16
2-2
SUPERSERVER 1027R-73DARF User's Manual
!
!
Warnings and Precautions!
•This product is not suitable for use with visual display work place devices
acccording to §2 of the the German Ordinance for Work with Visual Display
Units.
Rack Precautions
•Ensure that the leveling jacks on the bottom of the rack are fully extended to
the oor with the full weight of the rack resting on them.
•In single rack installation, stabilizers should be attached to the rack. In multiple
rack installations, the racks should be coupled together.
•Always make sure the rack is stable before extending a component from the
rack.
•You should extend only one component at a time - extending two or more si-
multaneously may cause the rack to become unstable.
Server Precautions
•Review the electrical and general safety precautions in Chapter 4.
•Determine the placement of each component in the rack before you install the
rails.
•Install the heaviest server components on the bottom of the rack rst, and then
work up.
•Use a regulating uninterruptible power supply (UPS) to protect the server from
power surges, voltage spikes and to keep your system operating in case of a
power failure.
•Allow the hot plug drives and power supply modules to cool before touching
them.
•Always keep the rack's front door and all panels and components on the servers
closed when not servicing to maintain proper cooling.
Page 17
Chapter 2: Server Installation
2-3
Rack Mounting Considerations
Ambient Operating Temperature
If installed in a closed or multi-unit rack assembly, the ambient operating tempera-
ture of the rack environment may be greater than the ambient temperature of the
room. Therefore, consideration should be given to installing the equipment in an
environment compatible with the manufacturer’s maximum rated ambient tempera-
ture (Tmra).
Reduced Airow
Equipment should be mounted into a rack so that the amount of airow required
for safe operation is not compromised.
Mechanical Loading
Equipment should be mounted into a rack so that a hazardous condition does not
arise due to uneven mechanical loading.
Circuit Overloading
Consideration should be given to the connection of the equipment to the power
supply circuitry and the effect that any possible overloading of circuits might have
on overcurrent protection and power supply wiring. Appropriate consideration of
equipment nameplate ratings should be used when addressing this concern.
Reliable Ground
A reliable ground must be maintained at all times. To ensure this, the rack itself
should be grounded. Particular attention should be given to power supply connec-
tions other than the direct connections to the branch circuit (i.e. the use of power
strips, etc.).
Page 18
2-4
SUPERSERVER 1027R-73DARF User's Manual
2-4 Installing the System into a Rack
This section provides information on installing the SuperServer 1027R-73DARF into
a rack. If the system has already been mounted into a rack, you can skip ahead
to Sections 2-5 and 2-6. Note: This rail will t a rack between 26" and 33.5" deep.
There are a variety of rack units on the market, which may mean the assembly
procedure will differ slightly. The following is a guideline for installing the 1027R-
73DARF into a rack with the rack rails provided. You should also refer to the instal-
lation instructions that came with the rack unit you are using.
Identifying the Sections of the Rack Rails
Each assembly consists of two sections: an inner xed chassis rail that secures
directly to the server chassis and an outer xed rack rail that secures directly to
the rack itself.
Figure 2-1. Identifying the Sections of the Rack Rails
Rail Extension
(Inner rail is pre-installed)
Outer Rails
Page 19
Chapter 2: Server Installation
2-5
Figure 2-2. Installing Chassis Rails
Inner Rails
The SC113 chassis includes a set of inner rails in two sections: inner rails and inner
rail extensions. The inner rails are pre-attached and do not interfere with normal use
of the chassis if you decide not to use a server rack. Attach the inner rail extension
to stabilize the chassis within the rack.
Installing the Inner Rails (Figure 2-2)
1. Place the inner rack extensions on the side of the chassis aligning the hooks
of the chassis with the rail extension holes. Make sure the extension faces
"outward" just like the pre-attached inner rail.
2. Slide the extension toward the front of the chassis.
3. Secure the chassis with two screws as illustrated.
4. Repeat steps 1-3 for the other inner rail extension.
1
2
3
Page 20
2-6
SUPERSERVER 1027R-73DARF User's Manual
Outer Rails
Installing the Outer Rails to the Rack (Figures 2-3 and 2-4)
1. Attach the short bracket to the outside of the long bracket. You must align the
pins with the slides. Also, both bracket ends must face the same direction.
2. Adjust both the short and long brackets to the proper distance so that the rail
ts snugly into the rack.
3. Secure the long bracket to the front side of the outer rail with two M5 screws
and the short bracket to the rear side of the outer rail with three M5 screws.
4. Repeat steps 1-4 for the left outer rail.
Secure to the
Front of the Rack
Secure to the
Rear of the Rack
Figure 2-3. Assembling the Outer Rails
Attach Outer Racks
Together
Page 21
Chapter 2: Server Installation
2-7
Figure 2-4. Installing the Outer Rails to the Rack
2
3
3
Page 22
2-8
SUPERSERVER 1027R-73DARF User's Manual
Figure 2-5. Installing the Server into a Rack
Installing the Chassis into a Rack (Figure 2-5)
1. Conrm that chassis includes the inner rails and rail extensions . Also, conrm
that the outer rails are installed on the rack.
2. Line chassis rails with the front of the rack rails.
3. Slide the chassis rails into the rack rails, keeping the pressure even on both
sides (you may have to depress the locking tabs when inserting). When the
server has been pushed completely into the rack, you should hear the locking
tabs "click".
4. (Optional) Insert and tightening the thumbscrews that hold the front of the
server to the rack.
Note: gures are for illustrative purposes only. Always install servers into racks
from the bottom up.
Page 23
Chapter 2: Server Installation
2-9
Installing the Server into a Telco Rack
To install the SuperServer 1027R-73DARF into a Telco type rack, use two L-shaped
brackets on either side of the chassis (four total). First, determine how far follow the
server will extend out the front of the rack. Larger chassis should be positioned to
balance the weight between front and back. If a bezel is included on your server,
remove it. Then attach the two front brackets to each side of the chassis, then the
two rear brackets positioned with just enough space to accommodate the width of
the telco rack. Finish by sliding the chassis into the rack and tightening the brackets
to the rack.
Note: these gures are for illustration puposes only. Always install servers to the
bottom of a rack rst.
Figure 2-6. Installing the Server into a Telco Rack
Page 24
2-10
SUPERSERVER 1027R-73DARF User's Manual
Notes
Page 25
Chapter 3: System Interface
3-1
Chapter 3
System Interface
3-1 Overview
There are several LEDs on the control panel to keep you constantly informed of the
overall status of the system as well as the three buttons described below.
3-2 Control Panel Buttons
There are three buttons located on the front of the chassis: a reset button, a power
on/off button and a UID button.
Reset
Use the reset button to reboot the system.
Power
This is the main power button, which is used to apply or turn off the main system
power. Turning off system power with this button removes the main power but keeps
standby power supplied to the system.
UID
Depressing the UID (unit identier) button illuminates an LED on both the front
and rear of the chassis for easy system location in large stack congurations. The
LED will remain on until the button is pushed a second time. Another UID button
on the rear of the chassis serves the same function. See the table in Figure 3-1 for
descriptions of UID LED states.
Page 26
3-2
SUPERSERVER 1027R-73DARF User's Manual
3-3 Control Panel LEDs
The control panel located on the front of the SC113TQ chassis has ve LEDs. These
LEDs provide you with critical information related to different parts of the system.
This section explains what each LED indicates when illuminated and any corrective
action you may need to take.
Note: deactivating the UID LED must be performed in the same way it was activated.
(If the UID LED was activated via IPMI, you can only turn the LED off via IPMI and
not with the UID button.)
Information LED
This LED will be solid blue when the UID function has been activated. When this
LED ashes red, it indicates a fan failure. When red continuously it indicates an
overheat condition, which may be caused by cables obstructing the airow in the
system or the ambient room temperature being too warm. Check the routing of
the cables and make sure all fans are present and operating normally. You should
also check to make sure that the chassis covers are installed. Finally, verify that
the heatsinks are installed properly (see Chapter 5). This LED will remain ashing
or on as long as the indicated condition exists.
Information LED States
State Indication
Continuously On (Red) An overheat condition has occured.
Fast Blinking Red (1 Hz) Fan Failure
Slow Blinking Red (.25 Hz) Power Fail
Solid Blue Local UID button has been activated.
Blinking Blue IPM/Remote UID has been activated
Page 27
Chapter 3: System Interface
3-3
NIC1
Indicates network activity on LAN2 when ashing.
NIC2
Indicates network activity on LAN1 when ashing.
HDD
Indicates DVD-ROM/hard drive activity when ashing.
Power
Indicates power is being supplied to the system's power supply units. This LED
should normally be illuminated when the system is operating.
Page 28
3-4
SUPERSERVER 1027R-73DARF User's Manual
3-4 Hard Drive Carrier LEDs
Each hard drive carrier has two LEDs.
•Green: When illuminated, the green LED on the front of the drive carrier in-
dicates drive activity. A connection to the SATA backplane enables this LED to
blink on and off when that particular drive is being accessed.
•Red: The red LED indicates two states. When blinking, it indicates the drive
is rebuilding. When solid, it indicates a drive failure. If a drive fails, you should
be notied by your system management software. Please refer to Chapter 6 for
instructions on replacing failed drives.
Page 29
Chapter 4: System Safety
4-1
Chapter 4
System Safety
4-1 Electrical Safety Precautions
!
Basic electrical safety precautions should be followed to protect yourself from harm
and the SuperServer 1027R-73DARF from damage:
•Be aware of the locations of the power on/off switch on the chassis as well
as the room's emergency power-off switch, disconnection switch or electrical
outlet. If an electrical accident occurs, you can then quickly remove power from
the system.
•Do not work alone when working with high voltage components.
•Power should always be disconnected from the system when removing or install-
ing main system components, such as the serverboard, memory modules and
oppy drive. The 1027R-73DARF has more than one power supply. Disconnect
both power supply cords before servicing to avoid electrical shock.
•When working around exposed electrical circuits, another person who is familiar
with the power-off controls should be nearby to switch off the power if neces-
sary.
•Use only one hand when working with powered-on electrical equipment. This
is to avoid making a complete circuit, which will cause electrical shock. Use
extreme caution when using metal tools, which can easily damage any electrical
components or circuit boards they come into contact with.
•Do not use mats designed to decrease static electrical discharge as protection
from electrical shock. Instead, use rubber mats that have been specically
designed as electrical insulators.
•The power supply power cords must include a grounding plug and must be
plugged into grounded electrical outlets.
Page 30
4-2
SUPERSERVER 1027R-73DARF User's Manual
4-2 General Safety Precautions
Follow these rules to ensure general safety:
•Keep the area around the system clean and free of clutter.
•The 1027R-73DARF weighs approximately 39 lbs (17.72 kg) when fully loaded.
When lifting the system, two people at either end should lift slowly with their
feet spread out to distribute the weight. Always keep your back straight and lift
with your legs.
•Place the chassis top cover and any system components that have been re-
moved away from the system or on a table so that they won't accidentally be
stepped on.
•While working on the system, do not wear loose clothing such as neckties and
unbuttoned shirt sleeves, which can come into contact with electrical circuits or
be pulled into a cooling fan.
•Remove any jewelry or metal objects from your body, which are excellent metal
conductors that can create short circuits and harm you if they come into contact
with printed circuit boards or areas where power is present.
!
•Serverboard Battery: CAUTION - There is a danger of explosion if the onboard
battery is installed upside down, which will reverse its polarites (see Figure 4-1).
This battery must be replaced only with the same or an equivalent type recom-
mended by the manufacturer (CR2032). Dispose of used batteries according to
the manufacturer's instructions.
•DVD-ROM Laser: CAUTION - this server may have come equipped with a
DVD-ROM drive. To prevent direct exposure to the laser beam and hazardous
radiation exposure, do not open the enclosure or use the unit in any uncon-
ventional way.
•Mainboard replaceable soldered-in fuses: Self-resetting PTC (Positive Tempera-
ture Coefcient) fuses on the mainboard must be replaced by trained service
technicians only. The new fuse must be the same or equivalent as the one
replaced. Contact technical support for details and support.
Page 31
Chapter 4: System Safety
4-3
4-3 ESD Precautions
Electrostatic discharge (ESD) is generated by two objects with different electrical
charges coming into contact with each other. An electrical discharge is created to
neutralize this difference, which can damage electronic com ponents and printed
circuit boards. The following measures are generally sufcient to neutralize this
difference before contact is made to protect your equipment from ESD:
•Use a grounded wrist strap designed to prevent static discharge.
•Keep all components and printed circuit boards (PCBs) in their antistatic bags
until ready for use.
•Touch a grounded metal object before removing the board from the antistatic
bag.
•Do not let components or PCBs come into contact with your clothing, which may
retain a charge even if you are wearing a wrist strap.
•Handle a board by its edges only; do not touch its components, peripheral chips,
memory modules or contacts.
•When handling chips or modules, avoid touching their pins.
•Put the serverboard and peripherals back into their antistatic bags when not
in use.
•For grounding purposes, make sure your computer chassis provides excellent
conductivity between the power supply, the case, the mounting fasteners and
the serverboard.
!
•After accessing the inside of the system, close the system back up and secure
it to the rack unit after ensuring that all connections have been made.
Page 32
4-4
SUPERSERVER 1027R-73DARF User's Manual
4-4 Operating Precautions
Care must be taken to assure that the chassis cover is in place when the 1027R-
73DARF is operating to assure proper cooling. Out of warranty damage to the
system can occur if this practice is not strictly followed.
!
Figure 4-1. Installing the Onboard Battery
LITHIUM BATTERY
BATTERY HOLDER
BATTERY HOLDER
LITHIUM BATTERY
OR
!
Please handle used batteries carefully. Do not damage the battery in any way; a
damaged battery may release hazardous materials into the environment. Do not
discard a used battery in the garbage or a public landll. Please comply with the
regulations set up by your local hazardous waste management agency to dispose
of your used battery properly.
Page 33
Chapter 5: Advanced Serverboard Setup
5-1
Chapter 5
Advanced Serverboard Setup
This chapter covers the steps required to connect the data and power cables and
install add-on cards. All serverboard jumpers and connections are also described.
A layout and quick reference chart are included in this chapter for your reference.
Remember to completely close the chassis when you have nished working with
the serverboard to better cool and protect the system.
5-1 Handling the Serverboard
Electrostatic Discharge (ESD) can damage electronic com ponents. To prevent dam-
age to any printed circuit boards (PCBs), it is important to handle them very carefully
(see previous chapter). To prevent the serverboard from bending, keep one hand
under the center of the board to support it when handling. The following measures
are generally sufcient to protect your equipment from electric static discharge.
Precautions
•Use a grounded wrist strap designed to prevent ESD.
•Touch a grounded metal object before removing boards from antistatic bags.
•Handle a board by its edges only; do not touch its components, peripheral chips,
memory modules or gold contacts.
•When handling chips or modules, avoid touching their pins.
•Put the serverboard, add-on cards and peripherals back into their antistatic
bags when not in use.
•For grounding purposes, make sure your computer chassis provides excellent
conductivity between the power supply, the case, the mounting fasteners and
the serverboard.
Unpacking
The serverboard is shipped in antistatic packaging to avoid electrical static dis-
charge. When unpacking the board, make sure the person handling it is static
protected.
Page 34
5-2
SUPERSERVER 1027R-73DARF User's Manual
5-2 Connecting Cables
Now that the serverboard is installed, the next step is to connect the cables to the
board. These include the data cables for the peripherals and control panel and the
power cables.
Connecting Data Cables
The cables used to transfer data from the peripheral devices have been carefully
routed to prevent them from blocking the ow of cooling air that moves through
the system from front to back. If you need to disconnect any of these cables, you
should take care to keep them routed as they were originally after reconnecting
them (make sure the red wires connect to the pin 1 locations). The following data
cables (with their locations noted) should be connected. (See the layout on page
5-10 for connector locations.)
•SATA and SAS drive data cables (SAS0 ~ SAS7)
•Control Panel cable (JF1)
Important! Make sure the the cables do not come into contact with the fans.
Connecting Power Cables
The X9DRD-7LN4F has a 24-pin primary power supply connector (JPW1) for con-
nection to the ATX power supply. In addition, there are two 8-pin 12V processor
power connectors (JPW2 and JPW3) that must be connected to your power supply.
See Section 5-9 for power connector pin denitions.
Connecting the Control Panel
JF1 contains header pins for various front control panel connectors. See Figure 5-1
for the pin locations of the various front control panel buttons and LED indicators.
All JF1 wires have been bundled into a single cable to simplify this connection. Make
sure the red wire plugs into pin 1 as marked on the board. The other end connects
to the Control Panel PCB board, located just behind the system status LEDs on
the chassis. See Chapter 5 for details and pin descriptions.
Page 35
Chapter 5: Advanced Serverboard Setup
5-3
Figure 5-1. Control Panel Header Pins
5-3 Rear I/O Ports
The I/O ports are color coded in conformance with the PC 99 specication. See
Figure 5-2 below for the colors and locations of the various I/O ports.
Figure 5-2. Rear I/O Ports
Rear I/O Ports
1 COM Port 1 7 Gb LAN Port 1
2 USB Port 0 8 Gb LAN Port 3
3 USB Port 1 9 Gb LAN Port 2
4 Dedicated IPMI LAN 10 Gb LAN Port 4
5 USB Port 2 11 VGA Port
6 USB Port 3 12 UID Button
1
1
1
9
1
7
1
8
1
5
1
3
1
4
1
2
1
11
1
12
1
10
1
6
Power Button
Blue+ (OH/Fan Fail/ PWR FaiL/UID LED)
1
NIC1 Link LED
Reset Button
2
Power Fail LED
HDD LED
FP PWRLED
Reset
PWR
3.3 V
ID_UID_SW/3/3V Stby
Red+ (Blue LED Cathode)
Ground
Ground
1920
3.3V
X
Ground
NMI
X
NIC2 Link LED
NIC2 Activity LED
NIC1 Activity LED
Page 36
5-4
SUPERSERVER 1027R-73DARF User's Manual
1. There are two levers on the
LGA2011 socket. First press and
release the load lever labeled
'Open 1st'.
2. Press the second load lever
labeled 'Close 1st' to release the
load plate from its locked position.
Installing an LGA 2011 Processor
5-4 Installing the Processor and Heatsink
Caution: When handling the processor package, avoid placing direct pressure on
the label area of the fan.
Notes:
•Always connect the power cord last and always remove it before adding, re-
moving or changing any hardware components. Make sure that you install the
processor into the CPU socket before you install the CPU heatsink.
•If you buy a CPU separately, make sure that you use an Intel-certied multi-
directional heatsink only.
•Make sure to install the serverboard into the chassis before you install the CPU
heatsinks.
•When receiving a serverboard without a processor pre-installed, make sure that
the plastic CPU socket cap is in place and none of the socket pins are bent;
otherwise, contact your retailer immediately.
•Refer to the Supermicro web site for updates on CPU support.
OPEN 1st
WARNING!
OPEN 1st
WARNING!
Press down on
the lever labeled
'Close 1st'
Pull lever away from the socket
Page 37
Chapter 5: Advanced Serverboard Setup
5-5
Gently push down to pop the load plate open.
3. With the lever labeled 'Close 1st'
fully retracted, gently push down
on the 'Open 1st' lever to open the
load plate. Lift the load plate to
open it completely.
4. Using your thumb and the index
nger, remove the 'WARNING'
plastic cap from the socket.
5. Use your thumb and index nger
to hold the CPU by its edges. Align
the CPU keys, which are semi-
circle cutouts, against the socket
keys.
6. Once they are aligned, carefully
lower the CPU straight down into
the socket. (Do not drop the CPU
on the socket. Do not move the
CPU horizontally or vertically and
do not rub the CPU against any
pins of the socket, which may
damage the CPU or the socket.)
WARNING!
OPEN 1st
WARNING!
Socket Keys
CPU Keys
Page 38
5-6
SUPERSERVER 1027R-73DARF User's Manual
Caution: You can only install the CPU to the socket in one direction. Make sure
that the CPU is properly inserted into the socket before closing the load plate. If it
doesn't close properly, do not force it as it may damage your CPU. Instead, open
the load plate again and double-check that the CPU is aligned properly.
7. With the CPU in the socket, in-
spect the four corners of the CPU
to make sure that they are ush
with the socket.
8. Close the load plate. Lock the
lever labeled 'Close 1st', then lock
the lever labeled 'Open 1st'. Use
your thumb to gently push the
load levers down until the lever
locks.
9. Repeat steps to install to the
remaining CPU socket.
OPEN 1st
OPEN 1st
Lever Lock
Push down
and lock the
lever labeled
'Open 1st'.
Push down and lock the
level labeled 'Close 1st'.
Gently close
the load plate.
Page 39
Chapter 5: Advanced Serverboard Setup
5-7
Installing a Passive CPU Heatsink
1. Do not apply any thermal grease to the heatsink or the CPU die -- the re-
quired amount has already been applied.
2. Place the heatsink on top of the CPU so that the four mounting holes are
aligned with those on the serverboard and the heatsink bracket underneath.
3. Screw in two diagonal screws (i.e., the #1 and the #2 screws) until just snug
(do not over-tighten the screws to avoid possible damage to the CPU.)
4. Add the two remaining screws then fully tighten all four screws.
Removing the Heatsink
Caution: We do not recommend removing the CPU or the heatsink. However, if
you do need to remove the heatsink, please follow the instructions below to prevent
damage to the CPU or other components.
1. Unscrew the heatsink screws from the serverboard in the sequence shown
above.
2. Gently wriggle the heatsink to loosen it from the CPU (do not use excessive
force). Once the CPU is loose, remove the it from the CPU socket.
3. Clean the surface of the CPU and the heatsink, removing the used thermal
grease. Reapply the proper amount of thermal grease on the surface before
re-installing the CPU and the heatsink.
Figure 5-3. Installing the Heatsink
Loosen screws in sequence as shown.
Screw#2
Screw#1
Screw#3
Screw#4
Page 40
5-8
SUPERSERVER 1027R-73DARF User's Manual
Memory Support
The X9DRD-7LN4F supports up to 512 GB of ECC registered (RDIMM), ECC
Load Reduced (LRDIMM) or ECC/non-ECC unbuffered (UDIMM) DDR3-
1600/1333/1066/800 SDRAM in 16 DIMM sickets. All channels will run at the fastest
common frequency.
DIMM Installation
Installing Memory Modules
1. Insert the desired number of DIMMs into the memory slots starting with P1-
DIMMA1. See the Memory Installation Tables below.
2. Insert each DIMM module vertically into its slot. Pay attention to the notch
along the bottom of the module to avoid installing incorrectly (see Figure 5-3).
3. Use your thumbs to gently press down on both ends of the DIMM module
until it snaps into place in the slot. Repeat for all modules.
4. Press the release tabs to the locked positions to secure the DIMM module
into the slot.
Caution! Exercise extreme care when installing or removing DIMM modules to
prevent any possible damage.
5-5 Installing Memory
To Install: Insert module
vertically and press down until it snaps into place. Pay attention to the alignment notch at the bottom.
To Remove: Use your thumbs to gently push the release tabs near both ends of the module. This should release it from the slot.
Figure 5-3. DIMM Installation
Top View of DDR3 Slot
Release Tab
Release Tab
Notch should align with the receptive key point on the slot.
Notch
Notch
Front View
Page 41
Chapter 5: Advanced Serverboard Setup
5-9
DIMM Module Population Table
Follow the tables below when installing memory.
Processors and their Corresponding Memory Modules
CPU# Corresponding DIMM Modules
CPU 1 P1-
DIMMA1
P1­DIMMB1
P1­DIMMC1
P1­DIMMD1
P1­DIMMA2
P1­DIMMB2
P1­DIMMC2
P1­DIMMD2
CPU2 P2-
DIMME1
P2­DIMMF1
P2­DIMMG1
P2­DIMMH1
P2­DIMME2
P2­DIMM F2
P2­DIMMG2
P2­DIMMH2
Processor and Memory Module Population for Optimal Performance
Number of
CPUs+DIMMs
CPU and Memory Population Conguration Table
(For memory to work properly, please follow the instructions below.)
1 CPU & 2 DIMMs
CPU1 P1-DIMMA1/P1-DIMMB1
1 CPU & 4 DIMMs
CPU1 P1-DIMMA1/P1-DIMMB1, P1-DIMMC1/P1-DIMMD1
1 CPU &
5~8 DIMMs
CPU1 P1-DIMMA1/P1-DIMMB1, P1-DIMMC1/P1-DIMMD1 + Any memory pairs in P1­DIMMA2/P1-DIMMB2/P1-DIMMC2/P1-DIMMD2 slots
2 CPUs &
4 DIMMs
CPU1 + CPU2 P1-DIMMA1/P1-DIMMB1, P2-DIMME1/P2-DIMMF1
2 CPUs &
6 DIMMs
CPU1 + CPU2 P1-DIMMA1/P1-DIMMB1/P1-DIMMC1/P1-DIMMD1, P2-DIMME1/P2-DIMMF1
2 CPUs &
8 DIMMs
CPU1 + CPU2 P1-DIMMA1/P1-DIMMB1/P1-DIMMC1/P1-DIMMD1, P2-DIMME1/P2-DIMMF1/P2­DIMMG1/P2-DIMMH1
2 CPUs &
10~16 DIMMs
CPU1/CPU2 P1-DIMMA1/P1-DIMMB1/P1-DIMMC1/P1-DIMMD1, P2-DIMME1/P2-DIMMF1/P2­DIMMG1/P2-DIMMH1 + Any memory pairs in P1, P2 DIMM slots
2 CPUs &
16 DIMMs
CPU1/CPU2 P1-DIMMA1/P1-DIMMB1/P1-DIMMC1/P1-DIMMD1, P2-DIMME1/P2-DIMMF1/P2-DIM­MG1/P2-DIMMH1,P1-DIMMA2/P1-DIMMB2/P1-DIMMC2/P1-DIMMD2, P2-DIMME2/ P2-DIMMF2/P2-DIMMG2/P2-DIMMH2
Page 42
5-10
SUPERSERVER 1027R-73DARF User's Manual
Populating UDIMM (ECC/Non-ECC) Memory Modules
Intel E5-2600 Series Processor UDIMM Memory Support
Ranks Per
DIMM &
Data Width
Memory Capacity
Per DIMM
(See the Note below)
Speed (MT/s) and Voltage Validated by Slot per Channel
(SPC) and DIMM Per Channel (DPC)
1 Slot Per Channel 2 Slots Per Channel
1DPC 1DPC 2DPC
1.35V 1.5V 1.35V 1.5V 1.35V 1.5V
SRx8
Non-ECC
1GB 2GB 4GB NA 1066, 1333,
1600
NA 1066,
1333
NA 1066,
1333
DRx8
Non-ECC
2GB 4GB 8GB NA 1066, 1333,
1600
NA 1066,
1333
NA 1066,
1333
SRx16
Non-ECC
512MB 1GB 2GB NA 1066, 1333,
1600
NA 1066,
1333
NA 1066,
1333
SRx8 ECC 1GB 2GB 4GB 1066,
1333
1066, 1333,
1600
1333
1333
1066 1066,
1333
DRx8 ECC 2GB 4GB 8GB 1066,
1333
1066, 1333,
1600
1333
1333
1066 1066,
1333
Note: For detailed information on memory support and updates, please refer to the SMC Recommended Memory List posted on our website at http://www.supermicro.com/support/resources/mem.cfm.
Populating RDIMM (ECC) Memory Modules
Intel E5-2600 Series Processor RDIMM Memory Support
Ranks
Per
DIMM
& Data
Width
Memory Capacity
Per DIMM
(See the Note Below)
Speed (MT/s) and Voltage Validated by Slot per Channel (SPC) and
DIMM Per Channel (DPC)
1 Slot Per Channel 2 Slots Per Channel
1DPC 1DPC 2DPC
1.35V 1.5V 1.35V 1.5V 1.35V 1.5V
SRx8 1GB 2GB 4GB 1066,
1333
1066, 1333,
1600
1333
1066, 1333,
1600
1333
1066, 1333,
1600
DRx8 2GB 4GB 8GB 1066,
1333
1066, 1333,
1600
1333
1066, 1333,
1600
1333
1066, 1333,
1600
SRx4 2GB 4GB 8GB 1066,
1333
1066, 1333,
1600
1333
1066, 1333,
1600
1333
1066, 1333,
1600
DRx4 4GB 8GB 16GB 1066,
1333
1066, 1333,
1600
1333
1066, 1333,
1600
1333
1066, 1333,
1600
QRx4 8GB 16GB 32GB 800 1066 800 1066 800 800
QRx8 4GB 8GB 16GB 800 1066 800 1066 800 800
Note: For detailed information on memory support and updates, please refer to the SMC Recommended
Memory List posted on our website at http://www.supermicro.com/support/resources/mem.cfm.
Page 43
Chapter 5: Advanced Serverboard Setup
5-11
Populating LRDIMM (ECC) Memory Modules
Intel E5-2600 Series Processor LRDIMM Memory Support
Ranks Per
DIMM & Data
Width
(See the Note
Below)
Memory Capacity
Per DIMM
Speed (MT/s) and Voltage Validated
by Slot per Channel (SPC) and
DIMM Per Channel (DPC)
1 Slot Per
Channel
2 Slots Per
Channel
1DPC 1DPC and 2DPC
1.35V 1.5V 1.35V 1.5V
QRx4 (DDP) 16GB 32GB 1066,
1333
1066,
1333
1066 1066,
1333
QRx8 (P) 8GB 16GB 1066,
1333
1066,
1333
1066 1066,
1333
Note: For detailed information on memory support and updates, please refer to the SMC Recommended Memory List posted on our website at http://www.supermicro. com/support/resources/mem.cfm.
Other Important Notes and Restrictions
•For the memory modules to work properly, please install DIMM modules of the
same type, same speed and same operating frequency. Mixing of RDIMMs,
UDIMMs or LRDIMMs is not allowed. Do not install both ECC and non-ECC
memory modules on the same serverboard.
•Using DDR3 DIMMs with different operating frequencies is not allowed. All chan-
nels in a system will run at the lowest common frequency.
Page 44
5-12
SUPERSERVER 1027R-73DARF User's Manual
5-6 Adding PCI Add-On Cards
The 1027R-73DARF can accommodate one standard-size PCI-E 3.0 x8 add-on
(expansion) cards.
Installing an Add-on Card
1. Begin by removing the shield where the riser card is located.
2. Fully seat the card into the slot on the riser, pushing down with your thumbs
evenly on both sides of the card.
3. The PCI slot shields protect the serverboard and its components from EMI
and aid in proper ventilation, so make sure there is always a shield covering
each unused slot.
Page 45
Chapter 5: Advanced Serverboard Setup
5-13
Figure 5-4. X9DRD-7LN4F Layout
5-7 Serverboard Details
JPME1
JI2C1
VGA1
I-SATA1
I-SATA0
I-SATA5
I-SATA4
I-SATA3
I-SATA2
JIPMB1
JPME2
JPL1
JBR1
JWD1
JPG1
JPB1
JVRM_I2C1
JVRM_I2C2
JVR1
FAN5
FAN6
FAN8
FAN7
FAN1
FAN2
FAN3
FAN4
JF2
T-SGPIO1
T-SGPIO2
JUSB6
JSD1
JBT1
JBAT1
JTPM1
JF1
JPI2C1
JOH1
JI2C2
JL1
JSTBY1
JUIDB
J4
JD1
LED3
LEDM1
LED2
LAN2/4
LAN1/3
CPU1
CPU2
CPU2
CPU1
CPU2
CPU1
PWR I2C
UID
P2-DIMME1
P2-DIMMF2
P2-DIMMF1
P2-DIMMG2
P2-DIMMG1
P2-DIMMH2
P2-DIMMH1
P1-DIMMA2
P1-DIMMA1
P1-DIMMB2
P1-DIMMB1
P1-DIMMC1
P1-DIMMC2
P1-DIMMD1
P1-DIMMD2
USB4/5USB8/9
SLOT1 PCI-E 3.0 X8
SLOT2 PCI-E 3.0 X8
SLOT3 PCI-E 3.0 X8
SLOT4 PCI-E 3.0 X8
SLOT5 PCI-E 3.0 X8
USB6
TPM/PORT80
BUZZER
CMOS CLEAR
SLOT6 PCI-E 3.0 X8
COM2
USB2/3
COM1
USB0/1
SP1
CPU2
IPMI_LAN
CPU2
CPU2
Battery
BIOS
JPW1
JPW2
24-Pin Main PWR
8-Pin PWR
JPW4
P2-DIMME2
JPW3
8-Pin PWR
4-Pin PWR
L-SAS4~7
L-SAS0~3
LSI SAS CTRL
Intel PCH
JPS1
LAN CTRL
BMC
CPU1
X9DRD-7(J)LN4F
Rev. 1.01
Notes
• " " indicates the location of "Pin 1".
•Jumpers not indicated are for test purposes only.
Page 46
5-14
SUPERSERVER 1027R-73DARF User's Manual
X9DRD-7LN4F Quick Reference
Jumper Description Default Setting
JBT1 Clear CMOS See Section 5-9
JI2C1/JI2C2 SMB to PCI-E Slots Off (Disabled)
JPB1 BMC Enable/Disable Pins 1-2 (Enabled)
JPG1 VGA Enable/Disable Pins 1-2 (Enabled)
JPL1 GLAN1/GLAN2 Enable/Disable Pins 1-2 (Enabled)
JPS1 SAS Enable/Disable Pins 1-2 (Enabled)
JVRMI2C1/2 CPU1/2 VRM I2C Bus Pins 2-3 (Manufacturer's Default)
JWD1 Watch Dog Timer Pins 1-2 (Reset)
Connector Description
COM1/COM2 Backplane COM Port1/Front Accessible COM2 Header
FAN1~8 CPU/System Fan Headers
JD1 Speaker/Power LED Indicator
JF1 Front Panel Control Header
JF2 LAN3 (NIC3)/LAN4 (NIC4) LED Indicator Connector
JIPMB1 4-pin External BMC I2C Header (for IPMI Card)
JL1 Chassis Intrusion Header
JOH1 Overheat LED Indicator Header
JPI2C1 Power Supply SMBbus I2C Header
JPW1 24-Pin ATX Main Power Connector
JPW2/3 12V 8-Pin Power Connectors
JPW4 12V 4-Pin Power Connectors
JSD1 SATA DOM (Device on Module) Power Connector
JSTBY1 +5V Standby Power Header
JTPM1 TPM (Trusted Platform Module)/Port 80 Header
JUID UID (Unit Identication) Switch
LAN1/3, LAN2/4 Gigabit Ethernet Ports 1/2, 3/4
(IPMI) LAN Dedicated IPMI LAN
(I-)SATA0~5 SATA 3.0 (0~1) and SATA 2.0 (2~5) Ports (from Intel PCH)
(L)SAS0~3, 4~7 SAS 2.0 Ports 0~3, 4~7 (from LSI SAS 2308 Controller)
Page 47
Chapter 5: Advanced Serverboard Setup
5-15
Slots 1/2/6 (CPU1), Slots 3/4/5 (CPU2)
PCI-Express 3.0 x8 Slots
(T-)SGPIO 1/2 SATA General Purpose I/O Header
(BP) USB 0/1, 2/3 Back Panel USB 0/1, 2/3
(FP) USB 4/5, USB 8/9 Front Panel Accessible USB Connections (4/5, 8/9)
(FP) USB 6 Type A USB Embedded Drive Connector
VGA Backpanel VGA Port
LED Description State Status
LED2 Standby PWR LED Green: On Standby PWR On
LED3 Rear UID LED Blue: On Unit Identied
LEDM1 BMC Heartbeat LED Green: Blinking BMC Normal
Page 48
5-16
SUPERSERVER 1027R-73DARF User's Manual
Reset Button
The Reset Button connection is
located on pins 3 and 4 of JF1 and
attaches to the reset switch on the
computer chassis. See p. 5-4 and the
table on the right for pin denitions.
Power Button
The Power On connection is on pins
1 and 2 of JF1. These should be con-
nected to the chassis power button.
See p. 5-4 and the table on the right
for pin denitions.
5-8 Connector Denitions
ATX Power 24-pin Connector
Pin Denitions
Pin# Denition Pin # Denition
13 +3.3V 1 +3.3V
14 -12V 2 +3.3V
15 COM 3 COM
16 PS_ON 4 +5V
17 COM 5 COM
18 COM 6 +5V
19 COM 7 COM
20 Res (NC) 8 PWR_OK
21 +5V 9 5VSB
22 +5V 10 +12V
23 +5V 11 +12V
24 COM 12 +3.3V
Reset Button
Pin Denitions (JF1)
Pin# Denition
3 Reset
4 Ground
Power Button
Pin Denitions (JF1)
Pin# Denition
1 Power Signal
2 Ground
Secondary Power Connector
JPW2 and JPW3 must also be con-
nected to the power supply. See the
tables on the right for pin denitions.
+12V 8-pin Power Connector
Pin Denitions
Pins Denition
1 - 4 Ground
5 - 8 +12V
Warning: To provide adequate power
supply to the serverboard, be sure
to connect all four power connectors
to the power supply. Failure to do so
will void the manufacturer warranty on
your power supply and serverboard.
Power Connectors
A 24-pin main power supply connector
(JPW1), two 8-pin CPU power con-
nectors (JPW2/3) must be connected
to the power supply. These power
connectors meet the SSI EPS 12V
specication. See the table on the
right for pin denitions.
NC = No Connection
+12V 4-pin Power Connector
Pin Denitions
Pins Denition
1~2 Ground
3~4 +12V
Page 49
Chapter 5: Advanced Serverboard Setup
5-17
Overheat (OH)/Fan Fail/PWR Fail/ UID LED
Connect an LED cable to pins 7 and
8 of Front Control Panel to use the
Overheat/Fan Fail/Power Fail and
UID LED connections. The Red LED
on pin 7 provides warnings of over-
heat, fan failure or power failure. The
Blue LED on pin 8 works as the front
panel UID LED indicator. The Red
LED takes precedence over the Blue
LED by default. Refer to the table on
the right for pin denitions.
HDD LED
The HDD LED connection is located
on pins 13 and 14 of JF1. This LED
is used to display all IDE/SAS/SATA
activity. See p. 5-4 and the table on
the right for pin denitions.
NIC2 LED
Pin Denitions (JF1)
Pin# Denition
9 Vcc
10 Ground
HDD LED
Pin Denitions (JF1)
Pin# Denition
13 Vcc
14 HD Active
NIC2 LED
The LED connections for LAN2 are on
pins 9 and 10 of JF1. Attach an LED
cable to display network activity. See
p. 5-4 and the table on the right for
pin denitions.
NIC1 LED
Pin Denitions (JF1)
Pin# Denition
11 Vcc
12 Ground
NIC1 LED
The LED connections for LAN1 are
on pins 11 and 12 of JF1. Attach an
LED cable to display network activity.
See p. 5-4 and the table on the right
for pin denitions.
OH/Fan Fail Indicator
Status
State Denition
Off Normal
On Overheat
Flash­ing
Fan Fail
Power Fail LED
The Power Fail LED connection is
located on pins 5 and 6 of JF1. See
p. 5-4 and the table on the right for
pin denitions.
PWR Fail LED
Pin Denitions (JF1)
Pin# Denition
5 Vcc
6 Ground
OH/Fan Fail/ PWR Fail/Blue_UID
LED Pin Denitions (JF1)
Pin# Denition
7 Red_LED-Cathode/OH/Fan Fail/
Power Fail5.5V.SB
8 Blue_UID LED
Page 50
5-18
SUPERSERVER 1027R-73DARF User's Manual
Fan Headers
There are eight fan headers on the
serverboard, all of which are 4-pin
fans (Fan 1-Fan 8). Pins 1-3 of the
fan headers are backward compatible
with the traditional 3-pin fans. (Fan
speed control is supported with 4-pin
fans only.) See the table on the right
for pin denitions. The onboard fan
speeds are controlled by IPMI.
NMI Button
The non-maskable interrupt button
header is located on pins 19 and 20
of JF1. See p. 5-4 and the table on
the right for pin denitions.
NMI Button
Pin Denitions (JF1)
Pin# Denition
19 Control
20 Ground
Fan Header
Pin Denitions
Pin# Denition
1 Ground (Black)
2 +12V (Red)
3 Tachometer
4 PWR Modulation
Power On LED
The Power On LED connector is lo-
cated on pins 15 and 16 of JF1 (use
JLED for a 3-pin connector). This
connection is used to provide LED
indication of power being supplied to
the system. See p. 5-4 and the table
on the right for pin denitions.
Power LED
Pin Denitions (JF1)
Pin# Denition
15 5V Stby
16 Control
Serial Port Pin Denitions
(COM1/COM2)
Pin # Denition Pin # Denition
1 DCD 6 DSR
2 RXD 7 RTS
3 TXD 8 CTS
4 DTR 9 RI
5 Ground 10 NC
Chassis Intrusion
The Chassis Intrusion header is des-
ignated JL1. Attach a chassis intrusion
cable from the chassis to inform you of
a chassis intrusion when the chassis
is opened
Chassis Intrusion
Pin Denitions
Pin# Denition
1 Intrusion Input
2 Ground
Serial Ports
Two serial ports are included on the
serverboard. COM1 is a backpanel
port and COM2 is a header located
near PCI-E slot1 to provides front
access support. See the table on the
right for pin denitions.
Page 51
Chapter 5: Advanced Serverboard Setup
5-19
Ethernet Ports
Four Ethernet ports are located on the
I/O backplane. A dedicated IPMI LAN
port is also included to provide KVM
support for IPMI 2.0. These ports ac-
cept RJ45 type cables.
Universal Serial Bus (USB)
Four Universal Serial Bus ports (USB
0/1, USB 2/3) are located on the I/O
back panel. In addition, three USB
headers, located close to the I/O
Hub, provides four front-accessible
USB connections (USB 4/5, USB 8/9).
One Type A connector (USB6) also
supports front panel USB connection
(cables are not included). See the
tables on the right for pin denitions.
FP USB (4/5, 8/9, USB 6)
Pin Denitions
USB 4, 8, 6,
Pin # Denition
USB 5, 9
Pin # Denition
1 +5V 1 +5V
2 PO- 2 PO-
3 PO+ 3 PO+
4 Ground 4 Ground
5 NC 5 Key
Backplane
USB (0/1, 2/3)
Pin Denitions
Pin# Denition
1 +5V
2 PO-
3 PO+
4 Ground
5 NA
LAN Ports
Pin Denition
Pin# Denition
1 P2V5SB 10 SGND
2 TD0+ 11 Act LED
3 TD0- 12 P3V3SB
4 TD1+ 13 Link 100 LED (Yel-
low, +3V3SB)
5 TD1- 14 Link 1000 LED
(Yellow, +3V3SB)
6 TD2+ 15 Ground
7 TD2- 16 Ground
8 TD3+ 17 Ground
9 TD3- 18 Ground
UID Switch
Pin# Denition
1 Ground
2 Ground
3 Button In
4 Ground
UID LED (LED3)
Status
Color/State Status
Blue: On Unit Identied
Unit Identier Switch
The UID Switch is located next to the
VGA port on the backplane. The Rear
UID LED (LED3) is located next to the
UID switch. The control panel UID LED
connection is on pins 7/8 of JF1. Con-
nect a cable to pin 8 on JF1 for Front
Panel UID LED indication. When you
press the UID switch, both the rear
UID LED and control panel UID LED
indicators will be turned on. Press the
UID switch again to turn off both LED
Indicators. These indicators provide
easy identication of a system unit that
may be in need of service. UID can
also be triggered via IPMI.
Page 52
5-20
SUPERSERVER 1027R-73DARF User's Manual
T-SGPIO Headers
The SGPIO (Serial General Purpose
Input/Output) headers are used to
communicate with the enclosure
management chip on the backplane.
See the table on the right for pin
denitions.
T-SGPIO Header
Pin Denitions
Pin# Denition Pin Denition
1 NC 2 NC
3 Ground 4 DATA Out
5 Load 6 Ground
7 Clock 8 NC
Internal Buzzer (SP1)
Pin Denition
Pin# Denitions
Pin 1 Pos. (+) Beep In
Pin 2 Neg. (-) Alarm
Speaker
Power LED/Speaker
On the JD1 header, pins 1-3 are for
a power LED and pins 4-7 are for the
speaker. Close pins 4-7 with a jumper
to use an external speaker. If you wish
to use the onboard speaker, please
close pins 6-7. See the table on the
right for speaker pin denitions.
Speaker Connector
Pin Settings
Pin Setting Denition
Pins 4-7 External Speaker
Pins 6-7 Internal Speaker
Internal Speaker
The internal speaker, located at SP1,
can be used to provide audible indica-
tions for various beep codes. See the
table on the right for pin denitions..
PWR LED Connector
Pin Denitions
Pin Setting Denition
Pin 1 Anode (+)
Pin2 Cathode (-)
Pin3 NA
Overheat/Fan Fail LED
The JOH1 header is used to connect
an LED indicator to provide warnings
of chassis overheating and fan failure.
This LED will blink when a fan failure
occurs. Refer to the table on the right
for pin denitions.
OH/Fan Fail LED
Status
State Message
Solid Overheat
Blinking Fan Fail
Overheat LED
Pin Denitions
Pin# Denition
1 VDC
2 OH Active
Page 53
Chapter 5: Advanced Serverboard Setup
5-21
DOM Power Connector
A power connector for SATA DOM
(Disk On Module) devices is located at
JSD1. Connect an appropriate cable
here to provide power support for your
DOM devices.
DOM PWR
Pin Denitions
Pin# Denition
1 +5V
2 Ground
3 Ground
Power Supply SMBus I2C Header
The power System Management Bus
header at JPI2C1 is used to monitor
the status of the power supply, fan and
system temperature. See the table on
the right for pin denitions.
TPM Header/Port 80
A Trusted Platform Module/Port 80
header is located at JTPM1 to provide
TPM support and a Port 80 connec-
tion. Use this header to enhance
system performance and data secu-
rity. See the table on the right for pin
denitions.
TPM/Port 80 Header
Pin Denitions
Pin # Denition Pin # Denition
1 LCLK 2 GND
3 LFRAME# 4 <(KEY)>
5 LRESET# 6 +5V (X)
7 LAD 3 8 LAD 2
9 +3.3V 10 LAD1
11 LAD0 12 GND
13 SMB_CLK4 14 SMB_DAT4
15 +3V_DUAL 16 SERIRQ
17 GND 18 CLKRUN# (X)
19 LPCPD# 20 LDRQ# (X)
PWR SMB
Pin Denitions
Pin# Denition
1 Clock
2 Data
3 PWR Fail
4 Ground
5 +3.3V
IPMB
A System Management Bus header
for IPMI 2.0 is located at JIPMB1.
Connect the appropriate cable here
to use the IPMB I2C connection on
your system.
IPMB Header
Pin Denitions
Pin# Denition
1 Data
2 Ground
3 Clock
4 No Connection
Page 54
5-22
SUPERSERVER 1027R-73DARF User's Manual
Standby Power Header
The +5V Standby Power header is lo-
cated at JSTBY1. See the table on the
right for pin denitions. (You must also
have a card with a Standby Power con-
nector and a cable to use this feature.)
Standby PWR
Pin Denitions
Pin# Denition
1 +5V Standby
2 Ground
3 Wake-up
LAN3/LAN4 LED Indicators
The NIC (Network Interface Control-
ler) LED connections for LAN Ports 3
and 4 are located on pins 3/4 and 1/2
of JF2, respectively. Attach NIC LED
cables here to display network activi-
ties. Refer to the table on the right for
pin denitions.
Note: The NIC LED connections for
LAN Ports 1/2 are located on JF1.
LAN Ports 3/4 LED Indicators (JF2)
Pin Denitions
Pin# Denition Pin Denition
1 LAN4 Activity 2 LAN4 Link
3 LAN3 Activity 4 LAN3 Link
Page 55
Chapter 5: Advanced Serverboard Setup
5-23
5-9 Jumper Settings
Explanation of Jumpers
To modify the operation of the
serverboard, jumpers can be used
to choose between optional settings.
Jumpers create shorts between two
pins to change the function of the con-
nector. Pin 1 is identied with a square
solder pad on the printed circuit board.
See the serverboard layout pages for
jumper locations.
Note: On a two-pin jumper, "Closed"
means the jumper is on both pins and
"Open" means the jumper is either on
only one pin or completely removed.
Connector
Pins
Jumper
Setting
3 2 1
3 2 1
CMOS Clear
JBT1 is used to clear CMOS (which will also clear any passwords). Instead of pins,
this jumper consists of contact pads to prevent accidentally clearing the contents
of CMOS.
To clear CMOS,
1. First power down the system and unplug the power cord(s).
2. With the power disconnected, short the CMOS pads with a metal object such
as a small screwdriver.
3. Remove the screwdriver (or shorting device).
4. Reconnect the power cord(s) and power on the system.
Note: Do not use the PW_ON connector to clear CMOS.
SAS Enable
Jumper JPS1 allows the user to en-
able onboard LSI SAS support. The
default setting is on 1-2 to enable all
SAS ports. See the table on the right
for jumper settings.
SAS Enable/Disable
Jumper Settings
Jumper Setting Denition
1-2 Enabled (Default)
2-3 Disabled
Page 56
5-24
SUPERSERVER 1027R-73DARF User's Manual
VGA Enable/Disable
JPG1 allows you to enable or disable
the VGA port. The default position is on
pins 1 and 2 to enable VGA. See the
table on the right for jumper settings.
VGA Enable/Disable
Jumper Settings
Jumper Setting Denition
Pins 1-2 Enabled
Pins 2-3 Disabled
LAN Enable/Disable
JPL1 enables or disables the LAN
ports 1/2 and 3/4. See the table on the
right for jumper settings. The default
setting is Enabled.
LAN Enable/Disable
Jumper Settings
Jumper Setting Denition
1-2 Enabled
2-3 Disabled
BMC Enable
Jumper JPB1 allows you to enable
the embedded the Winbond WPCM
450 BMC (Baseboard Management
Controller) to provide IPMI 2.0/KVM
support. See the table on the right for
jumper settings.
BMC Enable
Jumper Settings
Jumper Setting Denition
Pins 1-2 BMC Enable
Pins 2-3 Disable
Watch Dog Enable/Disable
Jumper JWD controls the Watch Dog
function. Watch Dog is a system moni-
tor that can reboot the system when a
software application hangs. Jumping
pins 1-2 will cause WD to reset the sys-
tem if an application hangs. Jumping
pins 2-3 will generate a non-maskable
interrupt signal for the application that
hangs. See the table on the right for
jumper settings. Watch Dog must also
be enabled in BIOS.
Watch Dog
Jumper Settings
Jumper Setting Denition
Pins 1-2 Reset
Pins 2-3 NMI
Open Disabled
SMB Bus to PCI-Exp. Slots
Use Jumpers JI2C1 and JI2C2 to con-
nect the System Management Bus
(I2C) to PCI-Express slots in order to
improve PCI slot performance. These
two jumpers are to be set at the same
time. The default setting is Closed to
enable the connections. See the table
on the right for jumper settings.
I2C to PCI-E slots
Jumper Settings
Jumper Setting Denition
Closed Enabled (Default)
Open Disabled
Page 57
Chapter 5: Advanced Serverboard Setup
5-25
5-10 Onboard Indicators
LAN LEDs
The Ethernet ports (located beside the
VGA port) have two LEDs. On each
port, the yellow LED ashes to indi-
cate activity while the other LED may
be green, amber or off to indicate the
speed of the connection. See the table
on the right for the functions associ-
ated with the connection speed LED.
LAN1/2 LED
(Connection Speed Indicator)
LED Color Denition
Off NC or 10 Mbps
Green 100 Mbps
Amber 1 Gbps
Onboard Power LED
An Onboard Power LED is located at
LED2. This LED Indicator is lit when
the system is on. Be sure to unplug the
power cord before removing or adding
any components. See the table on the
right for more details.
IPMI Dedicated LAN LEDs
An additional Dedicated IPMI LAN port
is also located on the I/O backplane.
The amber LED on the right indicates
activity, while the green LED on the
left indicates the speed of the connec-
tion. See the table at right for more
information.
Link LED
Activity LED
IPMI LAN
IPMI LAN Link LED (Left) &
Activity LED (Right)
LED Status Denition
Link Green: Solid 100 Mbps
Activity Amber: Blinking Active
BMC Heartbeat LED
A BMC Heartbeat LED is located at
LEMD1. When blinking, the BMC is
functioning normally.
BMC Heartbeat LED
LED Denition
D1 Blinking: BMC: Normal
Onboard PWR LED Indicator
LED Color Denition
Off System Off (PWR cable
not connected)
Green System On
Green: Flashing Quickly
ACPI S1 State
Activity LED
Link LED
Activity LED
Link LED
Page 58
5-26
SUPERSERVER 1027R-73DARF User's Manual
5-11 SATA and SAS Ports
SAS Port
Pin Denitions
Pin# Denition Pin Denition
1 Ground 2 TXP
3 TXN 4 Ground
5 RXN 6 RXP
7 Ground
SATA Port
Pin Denitions
Pin# Denition Pin Denition
1 Ground 2 TXP
3 TXN 4 Ground
5 RXN 6 RXP
7 Ground
Serial ATA Ports
There are six Serial ATA Ports (I-
SATA0~I-SATA 5) located on the
serverboard, including four SATA2
ports and two SATA3 ports. These
ports provide serial-link signal con-
nections, which are faster than Paral-
lel ATA. See the table on the right for
pin denitions.
SAS Ports
Eight Serial Attached SCSI ports
(SAS 0~3, 4~7) provide serial link
connections. These ports are sup-
ported by an LSI 2208 ccontroller.
See the table on the right for pin
denitions.
Unit Identication Switch/LED
A Unit Identier switch (UID) and a
rear UID LED indicator (LED3) are
located next to LAN ports on the back
of the chassis. When the user pushes
the rear UID switch, the rear UID LED
(LED3) will be turned on. Push the UID
switch again to turn off the LED indi-
cator. The UID switch provides easy
identication of a system unit that may
be in need of service. See the tables
on the right for more information.
UID LED
Status
Color/State OS Status
Blue: On Windows OS Unit Identied
Blue: Blinking
Linux OS Unit Identied
Page 59
Chapter 5: Advanced Serverboard Setup
5-27
5-12 Installing Software
After the hardware has been installed, you should rst install the operating system
and then the drivers. The necessary drivers are all included on the Supermicro CDs
that came packaged with your serverboard.
Driver/Tool Installation Display Screen
Note: Click the icons showing a hand writing on paper to view the readme les
for each item. Click the computer icons to the right of these items to install each
item (from top to the bottom) one at a time. After installing each item, you must
re-boot the system before moving on to the next item on the list. The bottom
icon with a CD on it allows you to view the entire contents of the CD.
Page 60
5-28
SUPERSERVER 1027R-73DARF User's Manual
Supero Doctor III Interface Display Screen (Health Information)
SuperDoctor III
The SuperDoctor® III program is a Web base management tool that supports remote
management capability. It includes Remote and Local Management tools. The local
management is called SD III Client. The SuperDoctor III program included on the
CD-ROM that came with your serverboard allows you to monitor the environment
and operations of your system. SuperDoctor III displays crucial system information
such as CPU temperature, system voltages and fan status. See the Figure below
for a display of the SuperDoctor III interface.
Note: The default User Name and Password for SuperDoctor III is ADMIN / ADMIN.
Note: When SuperDoctor is rst installed, it adopts the temperature threshold set-
tings that have been set in BIOS. Any subsequent changes to these thresholds
must be made within SuperDoctor, as the SuperDoctor settings override the BIOS
settings. To set the BIOS temperature threshold settings again, you would rst need
to uninstall SuperDoctor.
Page 61
Chapter 5: Advanced Serverboard Setup
5-29
Supero Doctor III Interface Display Screen (Remote Control)
Note: The SuperDoctor III program and User's Manual can be downloaded from the
Supermicro web site at http://www.supermicro.com/products/accessories/software/
SuperDoctorIII.cfm.
For Linux, we recommend using SuperDoctor II.
Page 62
5-30
SUPERSERVER 1027R-73DARF User's Manual
Notes
Page 63
Chapter 6: Advanced Chassis Setup
6-1
Chapter 6
Advanced Chassis Setup
This chapter covers the steps required to install components and perform mainte-
nance on the SC113 chassis. For component installation, follow the steps in the
order given to eliminate the most common problems encountered. If some steps
are unnecessary, skip ahead to the next step.
Tools Required: The only tool you will need to install components and perform
maintenance is a Philips screwdriver.
6-1 Static-Sensitive Devices
Electrostatic discharge (ESD) can damage electronic com ponents. To prevent
damage to any printed circuit boards (PCBs), it is important to handle them very
carefully.
The following measures are generally sufcient to protect your equipment from
ESD damage.
Precautions
•Use a grounded wrist strap designed to prevent static discharge.
•Touch a grounded metal object before removing any board from its antistatic
bag.
•Handle a board by its edges only; do not touch its components, peripheral chips,
memory modules or gold contacts.
•When handling chips or modules, avoid touching their pins.
•Put the serverboard, add-on cards and peripherals back into their antistatic
bags when not in use.
•For grounding purposes, make sure your computer chassis provides excellent
conductivity between the power supply, the case, the mounting fasteners and
the serverboard.
Page 64
6-2
SUPERSERVER 1027R-73DARF Manual
Figure 6-1. Chassis: Front and Rear Views
6-2 Control Panel
The control panel (located on the front of the chassis) must be connected to the
JF1 connector on the serverboard to provide you with system status indications. A
ribbon cable has bundled these wires together to simplify the connection. Connect
the cable from JF1 on the serverboard to the appropriate header on the Control
Panel PCB (printed circuit board). Make sure the red wire plugs into pin 1 on both
connectors. Pull all excess cabling out of the airow path.
The control panel LEDs inform you of system status. See "Chapter 3: System In-
terface" for details on the LEDs and the control panel buttons. Details on JF1 can
be found in "Chapter 5: Advanced Serverboard Installation."
6-3 System Cooling
Six 4-cm heavy-duty counter-rotating fans provide the cooling for the system.
Each fan unit is actually made up of two fans joined back-to-back, which rotate in
opposite directions. This counter-rotating action generates exceptional airow and
works to dampen vibration levels. The SC113 chassis provides two additional open
fan housings, where an additional system fan may be added for optimal cooling.
System Fan Failure
Fan speed is controlled by system temperature via IPMI. If a fan fails, the remaining
fans will ramp up to full speed. Replace any failed fan at your earliest convenience
with the same type and model (the system can continue to run with a failed fan).
The 1027R-73DARF system includes six pre-installed fans.
Control PanelDVD-ROM Drive (optional)
Hot-Swap Drive Bays (8)
I/O Ports (see Figure 5-2)
Power Supplies
PCI Expansion Slot (w/ Riser Card)
Page 65
Chapter 6: Advanced Chassis Setup
6-3
Replacing a System Fan (Figure 6-2)
1. Open the chassis while the system is running to determine which fan has
failed. Never run the server for an extended period of time with the chassis
open.
2. Turn off the power to the system and unplug the power cord from the power
supply.
3. Remove the failed fan's wiring from the fan header on the serverboard.
4. Lift the failed fan from the chassis and pull it completely out.
5. Place the new fan into the vacant space in the housing while making sure the
arrows on the top of the fan (indicating air direction) point in the same direc-
tion as the arrows on the other fans.
6. Reconnect the fan wires to the same chassis fan header as the previous fan.
7. Power up the system and check that the fan is working properly before re-
placing the chassis cover.
Page 66
6-4
SUPERSERVER 1027R-73DARF Manual
6-4 Drive Bay Installation/Removal
Accessing the Drive Bays
Hard Drives: Because of their hotswap capability, you do not need to access the
inside of the chassis or power down the system to install or replace hard drives.
Proceed to the next section for instructions.
DVD-ROM Drive: For installing/removing a DVD-ROM drive, you will need to gain
access to the inside of the system by removing the top cover of the chassis. Proceed
to the "DVD-ROM Drive Installation" section later in this chapter for instructions.
Note: Only a "slim" DVD-ROM drive will t into the 1027R-73DARF.
Hard Drive Installation
The hard drives are mounted in drive carriers to simplify their installation and
removal from the chassis. These carriers also help promote proper airow for
the drive bays. For this reason, even empty carriers without drives installed must
remain in the chassis.
Installing a Hard Drive into a Drive Carrier (Figure 6-3)
1. Insert a drive into the carrier with the PCB side facing down and the connec-
tor end toward the rear of the carrier.
Figure 6-2: Replacing a System Fan
Page 67
Chapter 6: Advanced Chassis Setup
6-5
2. Align the drive in the carrier so that the screw holes of both line up. Note that
there are holes in the carrier marked “SATA” to aid in correct installation.
3. Secure the drive to the carrier with four screws as illustrated below.
4. Insert the drive carrier into its bay, keeping the carrier oriented so that the
hard drive is on the top of the carrier and the release button is on the right
side. When the carrier reaches the rear of the bay, the release handle will
retract.
5. Push the handle in until it clicks into its locked position
Removing a Hard Drive (Figure 6-4)
1. To remove a carrier, push the release button located beside the drive LEDs.
2. Swing the handle fully out and use it to pull the unit straight out (see Figure
6-4).
Caution: Except for short periods of time (such as for swapping hard
drives), do not operate the server with the hard drive carriers empty.
!
Figure 6-3: Installing a Hard Drive into a Carrier
Page 68
6-6
SUPERSERVER 1027R-73DARF Manual
Figure 6-4. Removing a Hard Drive
1
2
DVD Drive Installation
The SC113 chassis includes a pre-installed DVD-ROM.
Installing or Replacing a DVD-ROM Drive (Figure 6-5)
1. Power down the system and if necessary, remove the server from the rack
and the front bezel from the chassis.
2. Remove the chassis cover.
3. Unplug the drives power and data cables from the serverboard and/or back-
plane.
4. If you are adding a new drive: Remove the mini-bezel (grate) from the drive
bay The bezel can be removed by pulling out the hard drive beneath the
DVD-ROM, then pulling the mini-bezel forward.
If you are replacing a drive: Locate the locking tab at the rear (left hand side
when viewed from the front) of the DVD-ROM drive. Push the tab toward the
drive and push the drive unit out the front of the chassis.
Page 69
Chapter 6: Advanced Chassis Setup
6-7
5. Insert the new drive unit in the slot until the tab locks in place.
6. Reconnect the data and power cables.
7. Replace the chassis cover (replace the server in the rack, if necessary) and
power up the system.
Figure 6-5. Installing the DVD-ROM Drive
Drive Screw
Drive Screws
Mini Bezel Lock Screw
Page 70
6-8
SUPERSERVER 1027R-73DARF Manual
6-5 Power Supply
The SuperServer 1027R-73DARF has a 700W-750W redundant power supply,
which is auto-switching capable. This enables it to automatically sense and operate
with a 100V to 240V input voltage.
If either of the two power supply modules fail, the other module will take the full
load and allow the system to continue operation without interruption. The Universal
Information LED on the control panel will blink slowly and remain so until the failed
module has been replaced. Replacement modules can be ordered directly from
Supermicro (see contact information in the Preface). The power supply modules
have a hot-swap capability, meaning you can replace the failed module without
powering down the system.
Replacing the Power Supply (Figure 6-6)
1. Check the LEDs on the power supplies to determine which module has failed.
2. Unplug the power cord from the failed module.
3. Push the release tab (on the back of the power supply) as illustrated, then
pull the power supply out using the handle provided.
4. Push the new power supply module into the power bay until you hear a click
(replace with the same model).
5. Reconnect the power cord to the new module.
Figure 6-6. Removing/Replacing the Power Supply
Release Tab
Page 71
Chapter 7: BIOS
7-1
Chapter 7
BIOS
7-1 Introduction
This chapter describes the AMI BIOS Setup utility for the X9DRD-7JLN4F/X9DRD-
7LN4F It also provides the instructions on how to navigate the AMI BIOS Setup
utility screens. The AMI ROM BIOS is stored in a Flash EEPROM and can be
easily updated.
Starting BIOS Setup Utility
To enter the AMI BIOS Setup utility screens, press the <Del> key while the system
is booting up.
Note: In most cases, the <Del> key is used to invoke the AMI BIOS setup
screen. There are a few cases when other keys are used, such as <F3>,
<F4>, etc.
Each main BIOS menu option is described in this manual. The Main BIOS setup
menu screen has two main frames. The left frame displays all the options that can
be congured. Grayed-out options cannot be congured. Options in blue can be
congured by the user. The right frame displays the key legend. Above the key
legend is an area reserved for informational text. When an option is selected in
the left frame, it is highlighted in white. Often informational text will accompany it.
Note: The AMI BIOS has default informational messages built in. The
manufacturer retains the option to include, omit, or change any of these
informational messages.
The AMI BIOS Setup utility uses a key-based navigation system called "hot keys."
Most of the AMI BIOS setup utility "hot keys" can be used at any time during setup
navigation. These keys include <F3>, <F4>, <Enter>, <ESC>, arrow keys, etc.
Note 1: Options printed in Bold are default settings.
Note 2: <F3> is used to load optimal default settings. <F4> is used to save
the settings and exit the setup utility.
Page 72
7-2
SUPERSERVER 1027R-73DARF User's Manual
How To Change the Conguration Data
The conguration data that determines the system parameters may be changed by
entering the AMI BIOS Setup utility. This Setup utility can be accessed by pressing
<Delete> at the appropriate time during system boot.
Note: For AMI UEFI BIOS Recovery, please refer to the UEFI BIOS Re-
covery User Guide posted @http://www.supermicro.com/support/manuals/.
Starting the Setup Utility
Normally, the only visible Power-On Self-Test (POST) routine is the memory test.
As the memory is being tested, press the <Delete> key to enter the main menu of
the AMI BIOS Setup utility. From the main menu, you can access the other setup
screens. An AMI BIOS identication string is displayed at the left bottom corner of
the screen below the copyright message.
Warning! Do not upgrade the BIOS unless your system has a BIOS-related
issue. Flashing the wrong BIOS can cause irreparable damage to the sys-
tem. In no event shall the manufacturer be liable for direct, indirect, special,
incidental, or consequential damage arising from a BIOS update. If you have
to update the BIOS, do not shut down or reset the system while the BIOS
is being updated to avoid possible boot failure.
7-2 Main Setup
When you rst enter the AMI BIOS Setup utility, you will enter the Main setup screen.
You can always return to the Main setup screen by selecting the Main tab on the
top of the screen. The Main BIOS Setup screen is shown below.
Page 73
Chapter 7: BIOS
7-3
The AMI BIOS Main menu displays the following information:
System Date/System Time
Use this option to change the system time and date. Highlight System Time or
System Date using the arrow keys. Enter new values through the keyboard and
press <Enter>. Press the <Tab> key to move between elds. The date must be
entered in Day MM/DD/YY format. The time is entered in HH:MM:SS format. (Note:
The time is in the 24-hour format. For example, 5:30 P.M. appears as 17:30:00.).
Supermicro X9DRD-7LN4F
Version
This item displays the SMC version of the BIOS ROM used in this system.
Build Date
This item displays the date that the BIOS Setup utility was built.
Memory Information
Total Memory
This displays the amount of memory that is available in the system.
Page 74
7-4
SUPERSERVER 1027R-73DARF User's Manual
7-3 Advanced Setup Congurations
Select the Advanced tab to access the following submenu items.
Boot Feature
Quiet Boot
This feature allows the user to select bootup screen display between POST mes-
sages and the OEM logo. Select Disabled to display the POST messages. Select
Enabled to display the OEM logo instead of the normal POST messages. The op-
tions are Enabled and Disabled.
AddOn ROM Display Mode
Use this item to set the display mode for the Option ROM. Select Keep Current to
use the current AddOn ROM Display setting. Select Force BIOS to use the Option
ROM display mode set by the system BIOS. The options are Keep Current and
Force BIOS.
Bootup Num-Lock
Use this feature to set the Power-on state for the Numlock key. The options are
Off and On.
Wait For 'F1' If Error
Select Enabled to force the system to wait until the 'F1' key is pressed if an error
occurs. The options are Disabled and Enabled.
Interrupt 19 Capture
Interrupt 19 is the software interrupt that handles the boot disk function. When this
item is set to Enabled, the ROM BIOS of the host adaptors will "capture" Interrupt 19
Page 75
Chapter 7: BIOS
7-5
at bootup and allow the drives that are attached to these host adaptors to function
as bootable disks. If this item is set to Disabled, the ROM BIOS of the host adap-
tors will not capture Interrupt 19, and the drives attached to these adaptors will not
function as bootable devices. The options are Enabled and Disabled.
Power Conguration
Watch Dog Function
If enabled, the Watch Dog timer will allow the system to automatically reboot when
a non-recoverable error occurs that lasts for more than ve minutes. The options
are Enabled and Disabled.
Power Button Function
If this feature is set to Instant Off, the system will power off immediately as soon
as the user presses the power button. If this feature is set to 4 Seconds Override,
the system will power off when the user presses the power button for 4 seconds or
longer. The options are Instant Off and 4 Seconds Override.
Restore on AC Power Loss
Use this feature to set the power state after a power outage. Select Stay Off for the
system power to remain off after a power loss. Select Power On for the system
power to be turned on after a power loss. Select Last State to allow the system
to resume its last state before a power loss. The options are Stay Off, Power On,
and Last State.
CPU Conguration
This submenu displays the information of the CPU as detected by the BIOS. It also
allows the user to congure CPU settings.
Socket 1 CPU Information/Socket 2 CPU Information
This submenu displays the following information regarding the CPUs installed
in Socket 1/ Socket 2.
•Type of CPU
•CPU Signature
•Microcode Patch
•CPU Stepping
•Maximum / Minimum CPU Speed
Page 76
7-6
SUPERSERVER 1027R-73DARF User's Manual
•Processor Cores
•Intel HT (Hyper-Threading) Technology
•Intel VT-x Technology
•Intel SMX Technology
•L1 Data Cache / L1 Code Cache
•L2 Cache
•L3 Cache
CPU Speed
This item displays the speed of the CPU installed in Socket 1/Socket 2.
64-bit
This item indicates if the CPU installed in Socket 1 or Socket 2 supports 64-bit technology.
Clock Spread Spectrum
Select Enable to enable Clock Spectrum support, which will allow the BIOS to moni-
tor and attempt to reduce the level of Electromagnetic Interference caused by the
components whenever needed. The options are Disabled and Enabled.
RTID (Record Types IDs)
This feature displays the total number of Record Type IDs for local and remote
pools. The options are Optimal and Alternate.
Hyper-threading
Select Enabled to support Intel Hyper-threading Technology to enhance CPU per-
formance. The options are Enabled and Disabled.
Active Processor Cores
Set to Enabled to use a processor's second core and above. (Please refer to Intel's
website for more information.) The options are All, 1, 2, 4, and 6.
Limit CPUID Maximum
This feature allows the user to set the maximum CPU ID value. Enable this function
to boot the legacy operating systems that cannot support processors with extended
CPUID functions. The options are Enabled and Disabled (for the Windows OS).
Page 77
Chapter 7: BIOS
7-7
Execute-Disable Bit (Available if supported by the OS & the CPU)
Select Enabled to enable the Execute Disable Bit which will allow the processor
to designate areas in the system memory where an application code can execute
and where it cannot, thus preventing a worm or a virus from ooding illegal codes
to overwhelm the processor or damage the system during an attack. The default is
Enabled. (Refer to Intel and Microsoft Web sites for more information.)
Intel® AES-NI
Select Enable to use the Intel Advanced Encryption Standard (AES) New Instruc-
tions (NI) to ensure data security. The options are Enabled and Disabled.
MLC Streamer Prefetcher (Available when supported by the CPU)
If set to Enabled, the MLC (mid-level cache) streamer prefetcher will prefetch
streams of data and instructions from the main memory to the L2 cache to improve
CPU performance. The options are Disabled and Enabled.
MLC Spatial Prefetch (Available when supported by the CPU)
If this feature is set to Disabled, The CPU prefetches the cache line for 64 bytes.
If this feature is set to Enabled the CPU fetches both cache lines for 128 bytes as
comprised. The options are Disabled and Enabled.
DCU Streamer Prefetcher (Available when supported by the CPU)
Select Enabled to support Data Cache Unit (DCU) prefetch of L1 data to speed
up data accessing and processing in the DCU to enhance CPU performance. The
options are Disabled and Enabled.
DCU IP Prefetcher
Select Enabled for DCU (Data Cache Unit) IP Prefetcher support, which will prefetch
IP addresses to improve network connectivity and system performance. The options
are Enabled and Disabled.
Intel® Virtualization Technology (Available when supported by the CPU)
Select Enabled to support Intel Virtualization Technology, which will allow one
platform to run multiple operating systems and applications in independent parti-
tions, creating multiple "virtual" systems in one physical computer. The options
are Enabled and Disabled.
Note: If there is any change to this setting, you will need to power off and
restart the system for the change to take effect. Please refer to Intel’s
website for detailed information.)
Page 78
7-8
SUPERSERVER 1027R-73DARF User's Manual
CPU Power Management Conguration
This submenu allows the user to congure the following CPU Power Manage-
ment settings.
Power Technology
Select Energy Efciency to support power-saving mode. Select Custom to cus-
tomize system power settings. Select Disabled to disable power-saving settings.
The options are Disabled, Energy Efcient, and Custom. If the option is set to
Custom, the following items will display:
EIST (Available when Power Technology is set to Custom)
EIST (Enhanced Intel SpeedStep Technology) allows the system to au-
tomatically adjust processor voltage and core frequency to reduce power
consumption and heat dissipation. The options are Disabled (GV3 Disabled),
and Enabled (GV3 Enabled). (Note: GV3 is Intel Speedstep support used
on older platforms. Please refer to Intel’s website for detailed information.)
Turbo Mode (Available when Power Technology is set to Custom)
Select Enabled to use the Turbo Mode to boost system performance. The
options are Enabled and Disabled.
C1E Support (Available when Power Technology is set to Custom)
Select Enabled to enable Enhanced C1 Power State to boost system per-
formance. The options are Enabled and Disabled.
CPU C3 Report (Available when Power Technology is set to Custom)
Select Enabled to allow the BIOS to report the CPU C3 State (ACPI C2) to
the operating system. During the CPU C3 State, the CPU clock generator
is turned off. The options are Enabled and Disabled.
CPU C6 Report (Available when Power Technology is set to Custom)
Select Enabled to allow the BIOS to report the CPU C6 State (ACPI C3) to
the operating system. During the CPU C6 State, the power to all cache is
turned off. The options are Enabled and Disabled.
CPU C7 Report (Available when Power Technology is set to Custom)
Select Enabled to allow the BIOS to report the CPU C7 State (ACPI C3) to
the operating system. CPU C7 State is a processor-specic low C-State.
The options are Enabled and Disabled.
Page 79
Chapter 7: BIOS
7-9
Package C-State limit (Available when Power Technology is set to
Custom)
This feature allows the user to set the limit on the C-State package register.
The options are C0, C2, C6, and No Limit.
Energy/Performance Bias
Use this feature to select an appropriate fan setting to achieve maximum system
performance (with maximum cooling) or maximum energy efciency with maxi-
mum power saving). The fan speeds are controlled by the rmware management
via IPMI 2.0. The options are Performance, Balanced Performance, Balanced
Energy, and Energy Efcient.
Factory Long Duration Power Limit
This item displays the power limit (in watts) set by the manufacturer during which
long duration power is maintained.
Long Duration Power Limit
This item displays the power limit (in watts) set by the user during which long
duration power is maintained. The default setting is 0.
Factory Long Duration Maintained
This item displays the period of time (in seconds) set by the manufacturer during
which long duration power is maintained.
Long Duration Maintained
This item displays the period of time (in seconds) during which long duration
power is maintained. The default setting is 0.
Recommended Short Duration Power
This item displays the short duration power settings (in watts) recommended by
the manufacturer.
Short Duration Power Limit
During Turbo Mode, the system may exceed the processors default power setting
and exceed the Short Duration Power limit. By increasing this value, the proces-
sor can provide better performance for short duration. This item displays the time
period during which short duration power is maintained. The default setting is 0.
Page 80
7-10
SUPERSERVER 1027R-73DARF User's Manual
Chipset Conguration
North Bridge
This feature allows the user to congure the settings for the Intel North Bridge.
Integrated IO Conguration
Intel® VT-d
Select Enabled to enable Intel Virtualization Technology support for Direct I/O VT-d by reporting the I/O device assignments to the VMM (Virtual Machine
Monitor) through the DMAR ACPI Tables. This feature offers fully-protected I/O
resource sharing across Intel platforms, providing greater reliability, security
and availability in networking and data-sharing. The options are Enabled and
Disabled.
Intel® I/OAT
Select Enabled to enable Intel I/OAT (I/O Acceleration Technology), which sig-
nicantly reduces CPU overhead by leveraging CPU architectural improvements
and freeing the system resource for other tasks. The options are Disabled and
Enabled.
DCA Support
When set to Enabled, this feature uses Intel's DCA (Direct Cache Access)
Technology to improve data transfer efciency. The options are Enabled and
Disabled.
IIO 1 PCIe Port Bifurcation Control
This submenu congures the following IO PCIe Port Bifurcation Control settings
for IIO 1 PCIe ports to determine how the available PCI-Express lanes to be
distributed between the PCI-Exp. Root Ports.
CPU1 Slot1 PCI-E 3.0 x8 Link Speed/ CPU1 Slot2 PCI-E 3.0 x8 Link Speed/ CPU1 Slot6 PCI-E 3.0 x8 Link Speed/CPU2 Slot3 PCI-E 3.0 x8 Link Speed/CPU2 Slot4 PCI-E 3.0 x8 Link Speed/CPU2 Slot5 PCI-E 3.0 x8 Link Speed
Select GEN1 for the device installed on the slot specied to support PCI-Exp
Generation 1. Select GEN2 for the device installed on the slot specied to support
PCI-Exp Generation 2. Select GEN3 for the device installed on the slot specied
to support PCI-Exp Generation 3. The options are GEN1, GEN2, and GEN3.
Page 81
Chapter 7: BIOS
7-11
IIO 2 PCIe Port Bifurcation Control
This submenu congures the following IO PCIe Port Bifurcation Control settings
for IIO 2 PCIe ports to determine how the available PCI-Express lanes to be
distributed between the PCI-Exp. Root ports.
QPI Conguration
Current QPI Link
This item displays the current status of the QPI Link.
Current QPI Frequency
This item displays the frequency of the QPI Link.
Isoc
Select Enabled to enable Isochronous support to meet QoS (Quality of Service)
requirements. This feature is especially important for virtualization technology.
The options are Enabled and Disabled.
QPI (Quick Path Interconnect) Link Speed Mode
Use this feature to select data transfer speed for QPI Link connections. The
options are Slow and Fast.
QPI Link Frequency Select
Use this feature to select the desired QPI frequency. The options are Auto, 6.4
GT/s, 7.2 GT/s, and 8.0 GT/s.
DIMM Conguration
This section displays the following DIMM information.
Current Memory Mode
This item displays the current memory mode.
Current Memory Speed
This item displays the current memory speed.
Mirroring (Available when supported by the motherboard)
Memory mirroring creates a duplicate copy of the data stored in the memory to
enhance data security.
Sparing (Available when supported by the motherboard)
Memory sparing enhances system reliability, availability, and serviceability.
Page 82
7-12
SUPERSERVER 1027R-73DARF User's Manual
DIMM Information
CPU Socket 1 DIMM Information, CPU Socket 2 DIMM Information
The status of the memory modules detected by the BIOS will be displayed as
detected by the BIOS.
Memory Mode
When Independent is selected, all DIMMs are available to the operating system.
When Mirroring is selected, the motherboard maintains two identical copies of all
data in memory for data backup. When Lock Step is selected, the motherboard
uses two areas of memory to run the same set of operations in parallel. The
options are Independent, Mirroring, and Lock Step.
DRAM RAPL Mode
RAPL (Running Average Power Limit) provides mechanisms to enforce power
consumption limits on supported processors The options are Disabled, DRAM
RAPL MODE0, and DRAM RAPL MODE1.
DDR Speed
Use this feature to force a DDR3 memory module to run at a frequency other than
what is specied in the specication. The options are Force DDR3-800, Force
DDR3-1066, Force DDR3-1333, Force DDR3-1600 and Force SPD, and Auto.
Channel Interleaving
This feature selects from the different channel interleaving methods. The options
are Auto, 1 Way, 2 Way, 3, Way, and 4 Way.
Rank Interleaving
This feature allows the user to select a rank memory interleaving method. The
options are Auto, 1 Way, 2 Way, 4, Way, and 8 Way.
Patrol Scrub
Patrol Scrubbing is a process that allows the CPU to correct correctable memory
errors detected on a memory module and send the correction to the requestor
(the original source). When this item is set to Enabled, the IO hub will read and
write back one cache line every 16K cycles, if there is no delay caused by internal
processing. By using this method, roughly 64 GB of memory behind the IO hub
will be scrubbed every day. The options are Enabled and Disabled.
Demand Scrub
Demand Scrubbing is a process that allows the CPU to correct correctable
memory errors found on a memory module. When the CPU or I/O issues a
demand-read command, and the read data from memory turns out to be a
Page 83
Chapter 7: BIOS
7-13
correctable error, the error is corrected and sent to the requestor (the original
source). Memory is updated as well. Select Enabled to use Demand Scrubbing
for ECC memory correction. The options are Enabled and Disabled.
Data Scrambling
Select Enabled to enable data scrambling to ensure data security and integrity.
The options are Disabled and Enabled.
Device Tagging
Select Enabled to support device tagging. The options are Disabled and En-
abled.
Thermal Throttling
Throttling improves reliability and reduces power consumption in the proces-
sor via automatic voltage control during processor idle states. The options are
Disabled and CLTT (Closed Loop Thermal Throttling).
South Bridge Conguration
This feature allows the user to congure the settings for the Intel PCH chip.
PCH Information
This feature displays the following PCH information.
Name: This item displays the name of the PCH chip.
Stepping: This item displays the status of the PCH stepping.
USB Devices: This item displays the USB devices detected by the BIOS.
All USB Devices
This feature enables all USB ports/devices. The options are Disabled and Enabled.
(If set to Enabled, EHCI Controller 1 and Controller 2 will appear.)
EHCI Controller 1/EHCI Controller 2 (Available when All USB Devices is set to Enabled)
Select Enabled to enable EHCI (Enhanced Host Controller Interface) Controller 1
or Controller 2. The options are Disabled and Enabled.
Legacy USB Support (Available when USB Functions is not Disabled)
Select Enabled to support legacy USB devices. Select Auto to disable legacy sup-
port if USB devices are not present. Select Disabled to have USB devices available
for EFI (Extensive Firmware Interface) applications only. The settings are Enabled
Disabled, and Auto.
Page 84
7-14
SUPERSERVER 1027R-73DARF User's Manual
Port 60/64 Emulation
Select Enabled to enable I/O port 60h/64h emulation support for the legacy USB
keyboard so that it can be fully supported by the operating systems that does not
recognize a USB device. The options are Disabled and Enabled.
EHCI Hand-Off
This item is for operating systems that do not support Enhanced Host Controller
Interface (EHCI) hand-off. When enabled, EHCI ownership change will be claimed
by the EHCI driver. The options are Disabled and Enabled.
SATA Conguration
When this submenu is selected, the AMI BIOS automatically detects the presence
of IDE or SATA devices and displays the following items.
SATA Port0~SATA Port5: The AMI BIOS displays the status of each SATA port
as detected by the BIOS.
SATA Mode
Use this feature to congure SATA mode for a selected SATA port. The options are
Disabled, IDE Mode, AHCI Mode and RAID Mode. The following are displayed
depending on your selection:
IDE Mode
The following items are displayed when IDE Mode is selected:
Serial-ATA (SATA) Controller 0~1
Use this feature to activate or deactivate the SATA controller, and set the
compatibility mode. The options for SATA Controller 0 are Disabled, En-
hanced, and Compatible. The options for SATA Controller 1 are Disabled
and Enhanced.
AHCI Mode
The following items are displayed when the AHCI Mode is selected.
Aggressive Link Power Management
When Enabled, the SATA AHCI controller manages the power usage of
the SATA link. The controller will put the link in a low power mode during
extended periods of I/O inactivity, and will return the link to an active state
when I/O activity resumes. The options are Enabled and Disabled.
Page 85
Chapter 7: BIOS
7-15
Port 0~5 Hot Plug
Select Enabled to enable hot-plug support for a particular port, which will
allow the user to change a hardware component or device without shutting
down the system. The options are Enabled and Disabled.
Staggered Spin Up
Select Enabled to enable Staggered Spin-up support to prevent excessive
power consumption caused by multiple HDDs spinning-up simultaneously.
The options are Enabled and Disabled.
RAID Mode
The following items are displayed when RAID Mode is selected:
SATA RAID Option ROM
Use this feature to determine which SATA RAID device the system will boot
from. The options are Legacy and EFI.
Port 0~5 Hot Plug
Select Enabled to enable hot-plug support for the particular port. The options
are Enabled and Disabled.
PCIe/PCI/PnP Conguration
PCI ROM Priority
Use this feature to select the Option ROM to boot the system when there are
multiple Option ROMs available in the system. The options are Legacy ROM and
EFI Compatible ROM.
PCI Latency Timer
Use this feature to set the latency Timer of each PCI device installed on a PCI bus.
Select 64 to set the PCI latency to 64 PCI clock cycles. The options are 32, 64, 96,
128, 160, 192, 224 and 248.
Above 4G Decoding (Available if the system supports 64-bit PCI decoding)
Select Enabled to decode a PCI device that supports 64-bit in the space above 4G
Address. The options are Enabled and Disabled.
PERR# Generation
Select Enabled to allow a PCI device to generate a PERR number for a PCI Bus
Signal Error Event. The options are Enabled and Disabled.
Page 86
7-16
SUPERSERVER 1027R-73DARF User's Manual
SERR# Generation
Select Enabled to allow a PCI device to generate an SERR number for a PCI Bus
Signal Error Event. The options are Enabled and Disabled.
Maximum Payload
Select Auto to allow the system BIOS to automatically set the maximum payload
value for a PCI-E device to enhance system performance. The options are Auto,
128 Bytes and 256 Bytes.
Maximum Read Request
Select Auto to allow the system BIOS to automatically set the maximum Read
Request size for a PCI-E device to enhance system performance. The options are
Auto, 128 Bytes, 256 Bytes, 512 Bytes, 1024 Bytes, 2048 Bytes, and 4096 Bytes.
ASPM Support
This feature allows the user to set the Active State Power Management (ASPM)
level for a PCI-E device. Select Force L0s to force all PCI-E links to operate at L0s
state. Select Auto to allow the system BIOS to automatically set the ASPM level for
the system. Select Disabled to disable ASPM support. The options are Disabled,
Force L0s, and Auto.
Warning: Enabling ASPM support may cause some PCI-E devices to fail!
CPU1 Slot 1 PCI-E 3.0 x8 OPROM, CPU1 Slot 2 PCI-E 3.0 x8 OPROM, CPU2 Slot 3 PCI-E 3.0 x8 OPROM, CPU2 Slot 4 PCI-E 3.0 x8 OPROM, CPU2 Slot 5 PCI-E 3.0 x8 OPROM, CPU1 Slot 6 PCI-E 3.0 x 8 OPROM
Select Enabled to enable Option ROM support to boot the computer using a de-
vice installed on the slot specied above. The options are Enabled and Disabled.
Onboard LAN Option ROM Select
Select iSCSI to use the iSCSI Option ROM to boot the computer using a network
device. Select PXE (Preboot Execution Environment) to use an PXE Option ROM
to boot the computer using a network device. The options are PXE and iSCSI.
Load Onboard LAN1~LAN4 Option ROM
Select Enabled to enable the onboard LAN1 Option ROM~LAN4 Option ROM. This
is to boot the computer using a network device. The default setting for LAN1 Option
ROM is Enabled, and the default setting for LAN2~LAN4 Option ROM is Disabled.
Load Onboard SAS Option ROM
Select Enabled to use the onboard SAS Option ROM to boot the computer using
a SAS device. The options are Enabled and Disabled.
Page 87
Chapter 7: BIOS
7-17
VGA Priority
This feature allows the user to select the graphics adapter to be used as the primary
boot device. The options are Onboard, and Offboard.
Network Stack
Select Enabled enable PXE (Preboot Execution Environment) or UEFI (Unied
Extensible Firmware Interface) for network stack support. The options are Enabled
and Disabled.
Super IO Conguration
Super IO Chip: This item displays the Super IO chip used in the motherboard.
Serial Port 1 Conguration
Serial Port
Select Enabled to enable serial port 1. The options are Enabled and Disabled.
Device Settings
This item displays the settings of Serial Port 1.
Change Settings
This option species the base I/O port address and the Interrupt Request address of
Serial Port 1. Select Disabled to prevent the serial port from accessing any system
resources. When this option is set to Disabled, the serial port becomes unavailable.
The options are Auto, IO=3F8h; IRQ=4; IO=3F8h; IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12;
IO=2F8h; IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12; IO=3E8h; IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12;
IO=2E8h, and IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12.
Device Mode
Use this feature to select the desired mode for a serial port specied. The options
are Normal and High Speed.
Serial Port 2 Conguration
Serial Port
Select Enabled to enable serial port 2. The options are Enabled and Disabled.
Device Settings
This item displays the settings of Serial Port 2.
Page 88
7-18
SUPERSERVER 1027R-73DARF User's Manual
Change Settings
This option species the base I/O port address and the Interrupt Request address of
Serial Port 2. Select Disabled to prevent the serial port from accessing any system
resources. When this option is set to Disabled, the serial port becomes unavailable.
The options are Auto, IO=3F8h; IRQ=4; IO=3F8h; IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12;
IO=2F8h; IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12; IO=3E8h; IRQ=3, 4, 5, 6, 7, 9, 10, 11,
12; and IO=2E8h, and IRQ=3, 4, 5, 6, 7, 9, 10, 11, 12.
Device Mode
Use this feature to select the desired mode for a serial port specied. The options
are Normal and High Speed.
Serial Port 2 Attribute
Use this feature to select the attribute for this serial port. The options are SOL
(Serial Over LAN), and COM.
Serial Port Console Redirection
COM1, COM2/SOL
These two submenus allow the user to congure the following Console Redirection
settings for a COM Port specied by the user.
Console Redirection
Select Enabled to use a COM Port selected by the user for Console Redirection.
The options are Enabled and Disabled. The default setting for COM1 is Disabled,
and for COM2/SOL is Enabled.
Console Redirection Settings
This feature allows the user to specify how the host computer will exchange
data with the client computer, which is the remote computer used by the user.
Terminal Type
This feature allows the user to select the target terminal emulation type for Con-
sole Redirection. Select VT100 to use the ASCII Character set. Select VT100+ to
add color and function key support. Select ANSI to use the Extended ASCII Char-
acter Set. Select VT-UTF8 to use UTF8 encoding to map Unicode characters
into one or more bytes. The options are VT100, VT100+, VT-UTF8, and ANSI.
Bits Per second
Use this feature to set the transmission speed for a serial port used in Console
Redirection. Make sure that the same speed is used in the host computer and the
Page 89
Chapter 7: BIOS
7-19
client computer. A lower transmission speed may be required for long and busy
lines. The options are 9600, 19200, 38400, 57600 and 115200 (bits per second).
Data Bits
Use this feature to set the data transmission size for Console Redirection. The
options are 7 Bits and 8 Bits.
Parity
A parity bit can be sent along with regular data bits to detect data transmission
errors. Select Even if the parity bit is set to 0, and the number of 1's in data bits
is even. Select Odd if the parity bit is set to 0, and the number of 1's in data bits
is odd. Select None if you do not want to send a parity bit with your data bits
in transmission. Select Mark to add a mark as a parity bit to be sent along with
the data bits. Select Space to add a Space as a parity bit to be sent with your
data bits. The options are None, Even, Odd, Mark and Space.
Stop Bits
A stop bit indicates the end of a serial data packet. Select 1 Stop Bit for standard
serial data communication. Select 2 Stop Bits if slower devices are used. The
options are 1 and 2.
Flow Control
This feature allows the user to set the ow control for Console Redirection to
prevent data loss caused by buffer overow. Send a "Stop" signal to stop send-
ing data when the receiving buffer is full. Send a "Start" signal to start sending
data when the receiving buffer is empty. The options are None and Hardware
RTS/CTS.
VT-UTF8 Combo Key Support
Select Enabled to enable VT-UTF8 Combination Key support for ANSI/VT100
terminals. The options are Enabled and Disabled.
Recorder Mode
Select Enabled to capture the data displayed on a terminal and send it as text
messages to a remote server. The options are Disabled and Enabled.
Resolution 100x31
Select Enabled for extended-terminal resolution support. The options are Dis-
abled and Enabled.
Legacy OS Redirection Resolution
Use this feature to select the number of rows and columns used in Console
Redirection for legacy OS support. The options are 80x24 and 80x25.
Page 90
7-20
SUPERSERVER 1027R-73DARF User's Manual
Putty KeyPad
This feature selects Function Keys and KeyPad settings for Putty, which is a
terminal emulator designed for the Windows OS. The options are VT100, LINUX,
XTERMR6, SC0, ESCN, and VT400.
Serial Port for Out-of-Band Management/Windows Emergency Management Services (EMS)
The submenu allows the user to congure Console Redirection settings to support
Out-of-Band Serial Port management.
Console Redirection (for EMS)
Select Enabled to use a COM Port selected by the user for Console Redirection.
The options are Enabled and Disabled.
Console Redirection Settings (for EMS)
This feature allows the user to specify how the host computer will exchange
data with the client computer, which is the remote computer used by the user.
Out-of-Band Management Port
The feature selects a serial port used by the Microsoft Windows Emergency
Management Services (EMS) to communicate with a remote server. The options
are COM1 and COM2/SOL.
Terminal Type
This feature allows the user to select the target terminal emulation type for Con-
sole Redirection. Select VT100 to use the ASCII character set. Select VT100+
to add color and function key support. Select ANSI to use the extended ASCII
character set. Select VT-UTF8 to use UTF8 encoding to map Unicode characters
into one or more bytes. The options are ANSI, VT100, VT100+, and VT-UTF8.
Bits Per Second
This item sets the transmission speed for a serial port used in Console Redirec-
tion. Make sure that the same speed is used in the host computer and the client
computer. A lower transmission speed may be required for long and busy lines.
The options are 9600, 19200, 57600, and 115200 (bits per second).
Flow Control
This feature allows the user to set the ow control for Console Redirection to
prevent data loss caused by buffer overow. Send a "Stop" signal to stop send-
ing data when the receiving buffer is full. Send a "Start" signal to start sending
data when the receiving buffer is empty. The options are None, Hardware RTS/
CTS, and Software Xon/Xoff.
Page 91
Chapter 7: BIOS
7-21
Data Bits, Parity, Stop Bits
The status of these features is displayed.
ACPI Settings
Use this feature to congure Advanced Conguration and Power Interface (ACPI)
power management settings for your system.
ACPI Sleep State
Use this feature to select the ACPI State when the system is in sleep mode. Select
S1 (CPU_Stop_Clock) to erase all CPU caches and stop executing instructions.
Power to the CPU(s) and RAM is maintained, but RAM is refreshed. Select Sus-
pend Disabled to use power-reduced mode. Power will only be supplied to limited
components (such as RAMs) to maintain the most critical functions of the system.
The options are Suspend Disabled and S1 (CPU_Stop_Clock).
NUMA (NON-Uniform Memory Access)
This feature enables the Non-Uniform Memory Access ACPI support. The options
are Enabled and Disabled.
High Precision Event Timer
Select Enabled to activate the High Precision Event Timer (HPET) that produces
periodic interrupts at a much higher frequency than a Real-time Clock (RTC) does
in synchronizing multimedia streams, providing smooth playback, reducing the de-
pendency on other timestamp calculation devices, such as an x86 RDTSC Instruc-
tion embedded in the CPU. The High Performance Event Timer is used to replace
the 8254 Programmable Interval Timer. The options are Enabled and Disabled.
Trusted Computing (Available when a TPM device is detected by the BIOS)
Conguration
TPM Support
Select Enabled on this item and enable the TPM jumper on the motherboard to
enable TPM support to improve data integrity and network security. The options
are Enabled and Disabled.
TPM State
Select Enabled to enable TPM security settings to improve data integrity and
network security. The options are Disabled and Enabled.
Page 92
7-22
SUPERSERVER 1027R-73DARF User's Manual
Pending Operation
Use this item to schedule an operation for the security device. The options are
None, Enable Take Ownership, Disable Take Ownership, and TPM Clear.
Note: During restart, the computer will reboot in order to execute the pend-
ing operation and change the state of the security device.
Current Status Information: This item displays the information regarding the
current TPM status.
TPM Enable Status
This item displays the status of TPM Support to indicate if TPM is currently
enabled or disabled.
TPM Active Status
This item displays the status of TPM Support to indicate if TPM is currently ac-
tive or deactivated.
TPM Owner Status
This item displays the status of TPM Ownership.
Intel TXT (LT-SX) Conguration
Intel TXT (LT-SX) Hardware Support
This feature indicates if the following hardware components support the Intel
Trusted Execution Technology.
CPU: TXT (Trusted Execution Technology) Feature
Chipset: TXT (Trusted Execution Technology) Feature
Intel TXT (LT-SX) Conguration
This feature displays the following TXT conguration setting.
TXT (LT-SX) Support: This item indicates if the Intel TXT support is enabled
or disabled. The default setting is Disabled.
Intel TXT (LT-SX) Dependencies
This feature displays the features that need to be enabled for the Intel Trusted
Execution Technology to work properly in the system.
VT-d Support: Intel Virtualization Technology with Direct I/O support
VT Support: Intel Virtualization Technology support
Page 93
Chapter 7: BIOS
7-23
TPM Support: Trusted Platform support
TPM State: Trusted Platform state
ME Subsystem
This feature displays the following ME Subsystem Conguration settings.
•ME BIOS Interface Version
•ME Version
iSCSI Conguration: This item displays iSCSI conguration information:
iSCSI Initiator Name
This item displays the name of the iSCSI Initiator, which is a unique name used
in the world. The name must use IQN format. The following actions can also
be performed:
•Add an Attempt
•Delete Attempts
•Commit/Discard Changes and Exit
•Change Attempt Order
•Commit/Discard Changes and Exit
Intel® Ethernet Controller I350 Gigabit Network Connection: These items display the following information on the Intel I350 Gigabit network connections.
NIC Conguration
Link Speed
Use this feature to change the link speed and duplex for the current port. The op-
tions are AutoNeg, 10Mbps Half, 10Mbps Full, 100Mbps Half, and 100Mbps full.
Wake on LAN
Select enabled to wake the system with a magic packet. The options are En-
abled and Disabled.
Page 94
7-24
SUPERSERVER 1027R-73DARF User's Manual
Blink LEDs
This feature allows the user to specify the duration for LEDs to blink. The range is
from 0 ~ 15 seconds. The default setting is 0.
PORT CONFIGURATION INFORMATION
This section displays the following port information:
•UEFI Driver
•Adapter PBA
•Chip Type
•PCI Device ID
•PCI Bus:Device:Function
•Link Status
•Factory MAC Address / Alternate MAC Address
Page 95
Chapter 7: BIOS
7-25
7-4 Event Logs
Select the Event Logs tab to access the following submenu items.
Change SMBIOS Event Log Settings
This feature allows the user to congure SMBIOS Event settings.
Enabling/Disabling Options
SMBIOS Event Log
Select Enabled to enable SMBIOS (System Management BIOS) Event Logging
during system boot. The options are Enabled and Disabled.
Runtime Error Logging Support
Select Enabled to support Runtime Error Logging. The options are Enabled and
Disabled.
Memory Correctable Error Threshold
This feature allows the user to enter the threshold value for correctable memory
errors. The default setting is 10.
PCI Error Logging Support
Select Enabled to support error event logging for PCI slots. The options are Enabled
and Disabled.
Page 96
7-26
SUPERSERVER 1027R-73DARF User's Manual
Erasing Settings
Erase Event Log
Select Enabled to erase the SMBIOS (System Management BIOS) Event Log, which
is completed before a event logging is initialized upon system reboot. The options
are No, Yes, Next reset, and Yes, Every reset.
When Log is Full
Select Erase Immediately to immediately erase SMBIOS error event logs that ex-
ceed the limit when the SMBIOS event log is full. Select Do Nothing for the system
to do nothing when the SMBIOS event log is full. The options are Do Nothing and
Erase Immediately.
SMBIOS Event Log Standard Settings
Log System Boot Event
Select Enabled to log system boot events. The options are Disabled and Enabled.
MECI (Multiple Event Count Increment)
Enter the increment value for the multiple event counter. Enter a number from 1 to
255. The default setting is 1.
METW (Multiple Event Count Time Window)
This item allows the user to decide how long (in minutes) should the multiple event
counter wait before generating a new event log. Enter a number from 0 to 99. The
default setting is 60.
View SMBIOS Event Log
This item allows the user to view the event in the SMBIOS event log. Select this
item and press <Enter> to view the status of an event in the log.
Date/Time/Error Code/Severity
Page 97
Chapter 7: BIOS
7-27
7-5 IPMI
Select the IPMI (Intelligent Platform Management Interface) tab to access the fol-
lowing submenu items.
IPMI Firmware Revision
This item indicates the IPMI rmware revision used in your system.
IPMI Status
This item indicates the status of the IPMI rmware installed in your system.
System Event Log
Enabling/Disabling Options
SEL Components
Select Enabled for all system event logging at bootup. The options are Enabled
and Disabled.
Erasing Settings
Erase SEL
Select Yes, On next reset to erase all system event logs upon next system reboot.
Select Yes, On every reset to erase all system event logs upon each system reboot.
Select No to keep all system event logs after each system reboot. The options are
No, Yes, On next reset, and Yes, On every reset.
Page 98
7-28
SUPERSERVER 1027R-73DARF User's Manual
When SEL is Full
This feature allows the user to decide what the BIOS should do when the system
event log is full. Select Erase Immediately to erase all events in the log when the
system event log is full. The options are Do Nothing and Erase Immediately.
Custom EFI Logging Options
Log EFI Status Codes
Select Enabled to log EFI (Extensible Firmware Interface) Status Codes, Error
Codes or Progress Codes. The options are Enabled and Disabled.
Note: After making changes on a setting, be sure to reboot the system for
the changes to take effect.
BMC Network Conguration
LAN Channel 1: This feature allows the user to congure the settings for LAN1 Port.
Update IPMI LAN Conguration
This feature allows the BIOS to implement any IP/MAC address changes at the next
system boot. If the option is set to Yes, any changes made to the settings below will
take effect when the system is rebooted. The options are No and Yes.
Conguration Address Source
This feature allows the user to select the source of the IP address for this computer.
If Static is selected, you will need to know the IP address of this computer and enter
it to the system manually in the eld. If DHCP is selected, the BIOS will search for
a DHCP (Dynamic Host Conguration Protocol) server in the network that is at-
tached to and request the next available IP address for this computer. The options
are DHCP and Static. The following items are assigned IP addresses automatically
if DHCP is selected, or can be congured manually if Static is selected.
Station IP Address
This item displays the Station IP address for this computer. This should be in decimal
and in dotted quad form (i.e., 192.168.10.253).
Subnet Mask
This item displays the sub-network that this computer belongs to. The value of each
three-digit number separated by dots should not exceed 255.
Station MAC Address
This item displays the Station MAC address for this computer. Mac addresses are
6 two-digit hexadecimal numbers.
Page 99
Chapter 7: BIOS
7-29
Gateway IP Address
This item displays the Gateway IP address for this computer. This should be in
decimal and in dotted quad form (i.e., 192.168.10.253).
7-6 Boot
This submenu allows the user to congure the following boot settings for the
system.
Boot Option Priorities
Boot Option #1, Boot Option #2, Boot Option #3, etc.
Use this feature to specify the sequence of boot device priority.
Network Devices, Hard Disk Drives
Use these options to set the order of the legacy network and hard drive devices
detected by the motherboard.
Delete Boot Option
This feature allows the user to select a EFI boot device to delete from the boot
priority list.
Delete Boot Option
Select the desired boot device to delete.
Page 100
7-30
SUPERSERVER 1027R-73DARF User's Manual
7-7 Security
This menu allows the user to congure the following security settings for the
system.
Password Check
Use this feature to determine when a password entry is required. Select Setup to
require the password only when entering setup. Select Always to require the pass-
word when entering setup and on each boot. The options are Setup and Always.
Administrator Password
Use this feature to set the Administrator Password which is required to enter the
BIOS setup utility. The length of the password should be from 3 to 20 characters
long.