The information in this User’s Manual has been carefully reviewed and is believed to be accurate.
The vendor assumes no responsibility for any inaccuracies that may be contained in this document,
makes no commitment to update or to keep current the information in this manual, or to notify any
person or organization of the updates. Please Note: For the most up-to-date version of this
manual, please see our web site at www.supermicro.com.
Super Micro Computer, Inc. ("Supermicro") reserves the right to make changes to the product
described in this manual at any time and without notice. This product, including software and documentation, is the property of Supermicro and/or its licensors, and is supplied only under a license.
Any use or reproduction of this product is not allowed, except as expressly permitted by the terms
of said license.
IN NO EVENT WILL SUPERMICRO BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL,
SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO
USE THIS PRODUCT OR DOCUMENTATION, EVEN IF ADVISED OF THE POSSIBILITY OF
SUCH DAMAGES. IN PARTICULAR, SUPERMICRO SHALL NOT HAVE LIABILITY FOR ANY
HARDWARE, SOFTW ARE, OR DA TA STORED OR USED WITH THE PRODUCT, INCLUDING THE
COSTS OF REPAIRING, REPLACING, INTEGRATING, INSTALLING OR RECOVERING SUCH
HARDWARE, SOFTWARE, OR DATA.
Any disputes arising between manufacturer and customer shall be governed by the laws of Santa
Clara County in the State of California, USA. The State of California, County of Santa Clara shall
be the exclusive venue for the resolution of any such disputes. Super Micro's total liability for all
claims will not exceed the price paid for the hardware product.
FCC Statement: This equipment has been tested and found to comply with the limits for a Class A
digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the manufacturer’s instruction manual, may cause harmful interference
with radio communications. Operation of this equipment in a residential area is likely to cause harmful
interference, in which case you will be required to correct the interference at your own expense.
California Best Management Practices Regulations for Perchlorate Materials: This Perchlorate warning applies only to products containing CR (Manganese Dioxide) Lithium coin cells. “Perchlorate
Material-special handling may apply. See www.dtsc.ca.gov/hazardouswaste/perchlorate”
WARNING: Handling of lead solder materials used in this
product may expose you to lead, a chemical known to the
State of California to cause birth defects and other reproductive harm.
Manual Revision 1.0
Release Date: May 29, 2013
Unless you request and receive written permission from Super Micro Computer, Inc., you may not
copy any part of this document.
Information in this document is subject to change without notice. Other products and companies
referred to herein are trademarks or registered trademarks of their respective companies or mark
holders.
This manual is written for professional system integrators and PC technicians.
It provides information for the installation and use of the SuperServer 6017R73THDP+/6017R-73HDP+. Installation and maintenance should be performed by
experienced technicians only.
Manual Organization
Chapter 1: Introduction
The fi rst chapter provides a checklist of the main components included with the
server system and describes the main features of the serverboard and the chassis.
Preface
Chapter 2: Server Installation
This chapter describes the steps necessary to install the SuperServer into a rack and
check out the server confi guration prior to powering up the system. If your server
was ordered without processor and memory components, this chapter will refer you
to the appropriate sections of the manual for their installation.
Chapter 3: System Interface
Refer here for details on the system interface, which includes the functions and
information provided by the control panel on the chassis as well as other LEDs
located throughout the system.
Chapter 4: Standardized Warning Statements
You should thoroughly familiarize yourself with this chapter for a general overview
of safety precautions that should be followed when installing and servicing the
SuperServer 6017R-73THDP+/6017R-73HDP+.
Chapter 5: Advanced Serverboard Setup
Chapter 5 provides detailed information on the X9DRFF-7TG+/X9DRFF-7G+
serverboard, including the locations and functions of connections, headers and
jumpers. Refer to this chapter when adding or removing processors or main memory
and when reconfi guring the serverboard.
Refer to Chapter 6 for detailed information on the SC816LTS-655B server chassis.
You should follow the procedures given in this chapter when installing, removing
or reconfi guring SAS or peripheral drives and when replacing system power supply
modules and cooling fans.
Chapter 7: BIOS
The BIOS chapter includes an introduction to BIOS and provides detailed information on running the CMOS Setup Utility.
7-7 Secur it y ......................................................................................................... 7-28
7-8 Save & Exit ................................................................................................... 7-29
Appendix A BIOS Error Beep Codes
Appendix B System Specifi cations
viii
Chapter 1: Introduction
Chapter 1
Introduction
1-1 Overview
The SuperServer 6017R-73THDP+/6017R-73HDP+ is a high-end server comprised
of two main subsystems: the SC816LTS-655B 1U server chassis and the X9DRFF7TG+/X9DRFF-7G+ dual processor serverboard. Please refer to our web site for
information on operating systems that have been certifi ed for use with the system
(www.supermicro.com).
In addition to the serverboard and chassis, various hardware components have been
included with the 6017R-73THDP+/6017R-73HDP+, as listed below:
• Four 4-cm fans (FAN-0065L4)
• Four 4-cm fans (FAN-0088L4)
• One air shroud (MCP-310-19012-0N)
• Two passive CPU heatsinks (SNK-P0047PS)
• Riser Card: (see Section 5-6 for details)
One RSC-R1UFF-E8R
• SAS/SATA Accessories
Three backplanes (BPN-SAS-816T-A2, BPN-SAS-816T -A4, BPN-SAS-816T -A6)
At the heart of the SuperServer 6017R-73THDP+/6017R-73HDP+ lies the X9DRFF7TG+/X9DRFF-7G+, a dual processor serverboard based on the Intel® C602
chipset. Below are the main features of the serverboard. (See Figure 1-1 for a
block diagram of the chipset.)
Processors
The X9DRFF-7TG+/X9DRFF-7G+ supports single or dual Intel® E5-2600 Series
processors in LGA2011 sockets. Please refer to our web site for a complete listing
of supported processors (www.supermicro.com).
Memory
The X9DRFF-7TG+/X9DRFF-7G+ has 16 memory sockets that can support up to
512 GB of ECC registered DDR3-1600/1333/1066/800 RDIMMs or up to 128 GB
of unbuffered ECC/non-ECC DDR3-1600/1333/1066/800 UDIMMs. Please refer to
Chapter 5 for installing memory.
Onboard SAS
An LSI 23 08 SAS controller provides eight SAS2 ports. The SAS drives are connected to a backplane that provides power, bus termination and confi guration set-
tings. RA ID 0, 1 and 10 are su ppor ted.
Onboard Serial ATA
A SATA controller is integrated into the chipset to provide a six-port SATA subsystem. Two of the port s suppo r t SATA 3 .0 and fou r suppo r t SATA 2. 0 (see Chapter
5 for detai ls). RAI D 0, 1, 5 and 10 are suppor ted.
I/O Ports
The color-coded I/O ports located at the front of the server include a VGA (monitor) port, two USB 2.0 ports, two 1 Gb Ethernet ports (the X9DRFF-7TG+/6017R73THDP+ features two 10 Gb Ethernet ports) and one dedicated IPMI LAN port.
Graphics Controller
The X9DRFF-7TG+/X9DRFF-7G+ features an integrated Matrox G200ew, 16 MB
DDR2 graphics controller.
1-2
Chapter 1: Introduction
1-3 Server Chassis Features
The 6017R-73THDP+/6017R-73HDP+ is built upon the SC816LTS-655B chassis.
Details on the chassis and on servicing procedures can be found in Chapter 6. The
following is a general outline of the main features of the chassis.
System Power
The SC816LTS-655B features a single 650W power supply consisting of a single
power module. The system must be shut down when replacing or removing this
power supply module.
Hard Drives
The SC816LTS-655B chassis was des igned to supp ort 12 SAS/SATA fi xed hard
drives, w hich a re mounted i nside t he chas sis.
PCI Expansion Slots
One riser card is included with the system. The RSC-R1UFF-E8R supports one
standard size PCI-E 3.0 x8 add-on card. See our web site for details (http://www.
supermicro.com/products/nfo/UIO.cfm) and section 5-6 of this manual for details.
Front Control Panel
The chassis' control panel includes a single system power-on button, which also
functions as a UID indicator.
Cooling System
The SC816LTS-655B has an innovative cooling design that features four 4-cm
counter-rotating fans located in the middle section of the chassis and four 4-cm
exhaust fans. The power supply module also includes a cooling fan.
This chapter provides a quick setup checklist to get your SuperServer 6017R73THDP+/6017R-73HDP+ up and running. Following the steps in the order given
should enable you to have the system operational within a minimal amount of time.
This quick setup assumes that your system has come to you with the processor and
memory preinstalled. If your system is not already fully integrated with a motherboard, processor, system memory etc., please turn to the chapter or section noted
in each step for details on installing specifi c components.
2-2 Unpacking the System
You should inspect the box the server was shipped in and note if it was damaged
in any way. If the server itself shows damage, you should fi le a damage claim with
the carrier who delivered it.
Decide on a suitable location for the rack unit that will hold the server. It should
be situated in a clean, dust-free area that is well ventilated. Avoid areas where
heat, electrical noise and electromagnetic fi elds are generated. You will also need
it placed near a grounded power outlet. Read the Rack and Server Precautions in
the next section.
2-3 Preparing for Setup
The box the SuperServer 6017R-73THDP+/6017R-73HDP+ was shipped in should
include two sets of rail assemblies, six rail mounting brackets and the mounting
screws you will need to install the system into the rack. Follow the steps in the
order given to complete the installation process in a minimal amount of time. Please
read this section in its entirety before you begin the installation procedure outlined
in the sections that follow.
Choosing a Setup Location
• Leave enough clearance in front of the rack to enable you to open the front door
completely (~25 inches) and approximately 30 inches of clearance in the back
of the rack to allow for suffi cient airfl ow and ease in servicing.This product is for
installation only in a Restricted Access Location (dedicated equipment rooms,
service closets and the like).
• This product is not suitable for use with visual display work place devices
acccording to §2 of the the German Ordinance for Work with Visual Display
Units.
2-4 Warnings and Precautions
Rack Precautions
• Ensure that the leveling jacks on the bottom of the rack are fully extended to
the fl oor with the full weight of the rack resting on them.
• In single rack installation, stabilizers should be attached to the rack. In multiple
rack installations, the racks should be coupled together.
• Always make sure the rack is stable before extending a component from the
rack.
• You should extend only one component at a time - extending two or more si-
multaneously may cause the rack to become unstable.
Server Precautions
• Review the electrical and general safety precautions in Chapter 4.
• Determine the placement of each component in the rack before you install the
rails.
• Install the heaviest server components on the bottom of the rack fi rst, and then
work up.
• Use a regulating uninterruptible power supply (UPS) to protect the server from
power surges, voltage spikes and to keep your system operating in case of a
power failure.
• Allow the hot plug SATA drives and power supply modules to cool before touch-
ing them.
• Always keep the rack's front door and all panels and components on the servers
closed when not servicing to maintain proper cooling.
2-2
Chapter 2: Server Installation
Rack Mounting Considerations
Ambient Operating Temperature
If installed in a closed or multi-unit rack assembly, the ambient operating temperature of the rack environment may be greater than the ambient temperature of the
room. Therefore, consideration should be given to installing the equipment in an
environment compatible with the manufacturer’s maximum rated ambient temperature (Tmra).
Reduced Airfl ow
Equipment should be mounted into a rack so that the amount of airfl ow required
for safe operation is not compromised.
Mechanical Loading
Equipment should be mounted into a rack so that a hazardous condition does not
arise due to uneven mechanical loading.
Circuit Overloading
Consideration should be given to the connection of the equipment to the power
supply circuitry and the effect that any possible overloading of circuits might have
on overcurrent protection and power supply wiring. Appropriate consideration of
equipment nameplate ratings should be used when addressing this concern.
Reliable Ground
A reliable ground must be maintained at all times. To ensure this, the rack itself
should be grounded. Particular attention should be given to power supply connections other than the direct connections to the branch circuit (i.e. the use of power
strips, etc.).
Warning! To prevent bodily injury when mounting or servicing this unit in a
rack, you must take special precautions to ensure that the system remains
stable. The following guidelines are provided to ensure your safety:
• This unit should be mounted at the bottom of the rack if it is the only unit in
the rack.
• When mounting this unit in a partially fi lled rack, load the rack from the bottom
to the top with the heaviest component at the bottom of the rack.
• If the rack is provided with stabilizing devices, install the stabilizers before
This section provides information on installing the chassis into a rack unit with the
rails provided. There are a variety of rack units on the market, which may mean
that the assembly procedure will differ slightly from the instructions provided. You
should also refer to the installation instructions that came with the rack unit you are
using. NOTE: This rail will fi t a rack between 26.5" and 36.4" deep.
Identifying the Inner Rail and Inner Rail Extension
The SC816LT chassis includes mounting rails for installing the system into a rack.
Each assembly consists of two sections: An inner rail which is pre-installed on the
chassis, an inner rail extension, and an outer rail that secures to the rack. These
assemblies are specifi cally designed for the left and right side of the chassis
Locking Tabs
Each inner rail has a locking tab. This tab locks the chassis into place when installed
and pushed fully into the rack. These tabs also lock the chassis in place when fully
extended from the rack. This prevents the server from coming completely out of
the rack when when the chassis is pulled out for servicing.
Inner Rail
Extension
Inner Rail
Three
Screws
Three
Screws
Figure 2-1. Identifying the Inner Rails and Inner Rail Extensions
Locking Tab
2-4
Chapter 2: Server Installation
Attaching the Inner Rail
The SC816LT chassis ships with the inner rails already installed. In most cases it
is only necessary to install the inner rail extention.
Releasing Inner Rail from the Outer Rails
1. Identify the left and right inner rails and inner rail extensions as illustrated in
Figure 6-1.
2. Place the inner rail and inner rail extension against the side of the chassis.
3. Slide the inner rail and inner rail extension forward toward the front of the
chassis
4. Secure the inner rail and inner rail extension with three screws.
5. Repeat steps 1-4 with the remaining inner rail.
1
4
1
2
1
3
Figure 2-2. Attaching the Inner Rail and Inner Rail Extension
Warning: do not pick up the server with the front handles. They are de-
1. Attach the short bracket to the outside of the long bracket. You must align the
pins with the slides. Also, both bracket ends must face the same direction.
2-6
Chapter 2: Server Installation
Figure 2-4. Attaching the Outer Rails to a Rack
2. Adjust both the short and long brackets to the proper distance so that the rail
fi ts snugly into the rack.
3. Secure the long bracket to the front side of the outer rail with two M5 screws
and the short bracket to the rear side of the outer rail with three M5 screws.
Use a washer with each screw.
4. Repeat steps 1-4 for the remaining outer rail.
Stability hazard. The rack stabilizing mechanism must be in place, or the
rack must be bolted to the fl oor before you slide the unit out for servicing.
Failure to stabilize the rack can cause the rack to tip over.
Note: fi gures are for illustrative purposes only. Always install servers into racks
from the bottom up.
Chassis Installation
Installing the Chassis into a Rack
1. Confi rm that the rails are correctly installed on the rack.
2. Align the guides on the chassis with the front of the rails.
3. Slide the guides of the chassis into the rails, keeping the pressure even on
both sides, until the locking tabs click into place, securing chassis in a fully
extended position.
4. Simultaneously depress the locking tabs of both rails at the same time and
push the chassis all the way into the rack.
5. If necessary, use screws to secure the chassis handles to the front of the
rack.
2-8
Chapter 3: System Interface
Chapter 3
System Interface
3-1 Overview
The server chassis has a single power on/off button. No other buttons or indicators
are needed on the Hadoop server.
3-2 Control Panel Button
The power on/off button is located just to the right of the COM port on the front of
the chassis.
Power
The main power button is used to apply or remove power from the power supply to
the system. Turning off system power with this button removes the main power, but
keeps standby power supplied to the system. For this reason, you should unplug
the system before servicing. The power button has a built-in LED that will turn green
when the power is on.
The following statements are industry standard warnings, provided to warn the user
of situations which have the potential for bodily injury. Should you have questions
or experience difficulty, contact Supermicro's Technical Support department
for assistance. Only certifi ed technicians should attempt to install or confi gure
components.
Read this appendix in its entirety before installing or confi guring components in the
Supermicro chassis.
These warnings may also be found on our web site at http://www.supermicro.com/
about/policies/safety_information.cfm.
Warning Defi nition
Warning!
This warning symbol means danger. You are in a situation that could cause bodily
injury. Before you work on any equipment, be aware of the hazards involved with
electrical circuitry and be familiar with standard practices for preventing accidents.
Warnung
WICHTIGE SICHERHEITSHINWEISE
Dieses Warnsymbol bedeutet Gefahr. Sie befi nden sich in einer Situation, die zu
Verletzungen führen kann. Machen Sie sich vor der Arbeit mit Geräten mit den
Gefahren elektrischer Schaltungen und den üblichen Verfahren zur Vorbeugung
vor Unfällen vertraut. Suchen Sie mit der am Ende jeder Warnung angegebenen
Anweisungsnummer nach der jeweiligen Übersetzung in den übersetzten
Sicherheitshinweisen, die zusammen mit diesem Gerät ausgeliefert wurden.
BEWAHREN SIE DIESE HINWEISE GUT AUF.
INSTRUCCIONES IMPORTANTES DE SEGURIDAD
Este símbolo de aviso indica peligro. Existe riesgo para su integridad física. Antes
de manipular cualquier equipo, considere los riesgos de la corriente eléctrica y
familiarícese con los procedimientos estándar de prevención de accidentes. Al
fi nal de cada advertencia encontrará el número que le ayudará a encontrar el texto
traducido en el apartado de traducciones que acompaña a este dispositivo.
GUARDE ESTAS INSTRUCCIONES.
IMPORTANTES INFORMATIONS DE SÉCURITÉ
Ce symbole d'avertissement indique un danger. Vous vous trouvez dans une
situation pouvant entraîner des blessures ou des dommages corporels. Avant
de travailler sur un équipement, soyez conscient des dangers liés aux circuits
électriques et familiarisez-vous avec les procédures couramment utilisées pour
éviter les accidents. Pour prendre connaissance des traductions des avertissements
fi gurant dans les consignes de sécurité traduites qui accompagnent cet appareil,
référez-vous au numéro de l'instruction situé à la fi n de chaque avertissement.
이 경고 기호는 위험이 있음을 알려 줍니다. 작업자의 신체에 부상을 야기 할 수
있는 상태에 있게 됩니다. 모든 장비에 대한 작업을 수행하기 전에 전기회로와
관련된 위험요소들을 확인하시고 사전에 사고를 방지할 수 있도록 표준
작업절차를 준수해 주시기 바랍니다.
해당 번역문을 찾기 위해 각 경고의 마지막 부분에 제공된 경고문 번호를
참조하십시오
BELANGRIJKE VEILIGHEIDSINSTRUCTIES
Dit waarschuwings symbool betekent gevaar. U verkeert in een situatie die
lichamelijk letsel kan veroorzaken. Voordat u aan enige apparatuur gaat werken,
dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico's
en dient u op de hoogte te zijn van de standaard procedures om ongelukken te
voorkomen. Gebruik de nummers aan het eind van elke waarschuwing om deze te
herleiden naar de desbetreffende locatie.
Waarschuwing
Raadpleeg de installatie-instructies voordat u het systeem op de voedingsbron
aansluit.
4-4
Chapter 4: Warning Statements for AC Systems
Circuit Breaker
Warning!
This product relies on the building's installation for short-circuit (overcurrent)
protection. Ensure that the protective device is rated not greater than: 250 V, 20 A.
이 제품은 전원의 단락(과전류)방지에 대해서 전적으로 건물의 관련 설비에
의존합니다. 보호장치의 정격이 반드시 250V(볼트), 20A(암페어)를 초과하지
않도록 해야 합니다.
Waarschuwing
Dit product is afhankelijk van de kortsluitbeveiliging (overspanning) van
uw electrische installatie. Controleer of het beveiligde aparaat niet groter
gedimensioneerd is dan 220V, 20A.
Power Disconnection Warning
Warning!
The system must be disconnected from all sources of power and the power cord
removed from the power supply module(s) before accessing the chassis interior to
install or remove system components.
電源切断の警告
システムコンポーネントの取り付けまたは取り外しのために、シャーシー内部にアクセス
するには、
システムの電源はすべてのソースから切断され、電源コードは電源モジュールから取り
外す必要があります。
警告
在你打开机箱并安装或移除内部器件前,必须将系统完全断电,并移除电源线。
警告
在您打開機殼安裝或移除內部元件前,必須將系統完全斷電,並移除電源線。
Warnung
Das System muss von allen Quellen der Energie und vom Netzanschlusskabel
getrennt sein, das von den Spg.Versorgungsteilmodulen entfernt wird, bevor es
auf den Chassisinnenraum zurückgreift, um Systemsbestandteile anzubringen oder
zu entfernen.
4-6
Loading...
+ 80 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.