Supero 6017R-73THDP+, Supero 6017R-73HDP+, SUPERSERVER 6017R-73THDP+, SUPERSERVER 6017R-73HDP+ User Manual

SUPER
SUPERSERVER
6017R-73THDP+
6017R-73HDP+
®
USER’S MANUAL
1.0
manual, please see our web site at www.supermicro.com.
Super Micro Computer, Inc. ("Supermicro") reserves the right to make changes to the product described in this manual at any time and without notice. This product, including software and docu­mentation, is the property of Supermicro and/or its licensors, and is supplied only under a license. Any use or reproduction of this product is not allowed, except as expressly permitted by the terms of said license.
IN NO EVENT WILL SUPERMICRO BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL, SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO USE THIS PRODUCT OR DOCUMENTATION, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. IN PARTICULAR, SUPERMICRO SHALL NOT HAVE LIABILITY FOR ANY HARDWARE, SOFTW ARE, OR DA TA STORED OR USED WITH THE PRODUCT, INCLUDING THE COSTS OF REPAIRING, REPLACING, INTEGRATING, INSTALLING OR RECOVERING SUCH HARDWARE, SOFTWARE, OR DATA.
Any disputes arising between manufacturer and customer shall be governed by the laws of Santa Clara County in the State of California, USA. The State of California, County of Santa Clara shall be the exclusive venue for the resolution of any such disputes. Super Micro's total liability for all claims will not exceed the price paid for the hardware product.
FCC Statement: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environ­ment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the manufacturer’s instruction manual, may cause harmful interference with radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case you will be required to correct the interference at your own expense.
California Best Management Practices Regulations for Perchlorate Materials: This Perchlorate warn­ing applies only to products containing CR (Manganese Dioxide) Lithium coin cells. “Perchlorate Material-special handling may apply. See www.dtsc.ca.gov/hazardouswaste/perchlorate”
WARNING: Handling of lead solder materials used in this product may expose you to lead, a chemical known to the State of California to cause birth defects and other repro­ductive harm.
Manual Revision 1.0 Release Date: May 29, 2013
Unless you request and receive written permission from Super Micro Computer, Inc., you may not copy any part of this document.
Information in this document is subject to change without notice. Other products and companies referred to herein are trademarks or registered trademarks of their respective companies or mark holders.
Copyright © 2013 by Super Micro Computer, Inc. All rights reserved.
Printed in the United States of America
Preface
About This Manual
This manual is written for professional system integrators and PC technicians. It provides information for the installation and use of the SuperServer 6017R­73THDP+/6017R-73HDP+. Installation and maintenance should be performed by experienced technicians only.
Manual Organization
Chapter 1: Introduction
The fi rst chapter provides a checklist of the main components included with the server system and describes the main features of the serverboard and the chassis.
Preface
Chapter 2: Server Installation
This chapter describes the steps necessary to install the SuperServer into a rack and check out the server confi guration prior to powering up the system. If your server was ordered without processor and memory components, this chapter will refer you to the appropriate sections of the manual for their installation.
Chapter 3: System Interface
Refer here for details on the system interface, which includes the functions and information provided by the control panel on the chassis as well as other LEDs located throughout the system.
Chapter 4: Standardized Warning Statements
You should thoroughly familiarize yourself with this chapter for a general overview of safety precautions that should be followed when installing and servicing the SuperServer 6017R-73THDP+/6017R-73HDP+.
Chapter 5: Advanced Serverboard Setup
Chapter 5 provides detailed information on the X9DRFF-7TG+/X9DRFF-7G+ serverboard, including the locations and functions of connections, headers and jumpers. Refer to this chapter when adding or removing processors or main memory and when reconfi guring the serverboard.
iii
SUPERSERVER 6017R-73THDP+/6017R-73HDP+ User's Manual
Chapter 6: Advanced Chassis Setup
Refer to Chapter 6 for detailed information on the SC816LTS-655B server chassis. You should follow the procedures given in this chapter when installing, removing or reconfi guring SAS or peripheral drives and when replacing system power supply modules and cooling fans.
Chapter 7: BIOS
The BIOS chapter includes an introduction to BIOS and provides detailed informa­tion on running the CMOS Setup Utility.
Appendix A: BIOS Error Beep Codes
Appendix B: System Specifi cations
iv
Notes
Preface
v
SUPERSERVER 6017R-73THDP+/6017R-73HDP+ User's Manual
Table of Contents
Chapter 1 Introduction
1-1 Overview .........................................................................................................1-1
1-2 Serverboard Features .....................................................................................1-2
Processors ......................................................................................................1-2
Memory ...........................................................................................................1-2
Onboard SAS .................................................................................................. 1-2
Onboard Serial ATA ........................................................................................ 1-2
Rear I/O Ports ................................................................................................. 1-2
Graphics Controller .........................................................................................1-2
1-3 Server Chassis Features ................................................................................1-3
System Power ................................................................................................. 1-3
Hard Drives .....................................................................................................1-3
PCI Expansion Slots ....................................................................................... 1-3
Front Control Panel .........................................................................................1-3
Cooling System ............................................................................................... 1-3
1-4 Contacting Supermicro ....................................................................................1-5
Chapter 2 Server Installation
2-1 Overview .........................................................................................................2-1
2-2 Unpacking the System .................................................................................... 2-1
2-3 Preparing for Setup .........................................................................................2-1
Choosing a Setup Location ............................................................................. 2-1
2-4 Warnings and Precautions .............................................................................. 2-2
Rack Precautions ............................................................................................ 2-2
Server Precautions .......................................................................................... 2-2
Rack Mounting Considerations .......................................................................2-3
Ambient Operating Temperature ................................................................ 2-3
Reduced Airfl ow .........................................................................................2-3
Mechanical Loading ................................................................................... 2-3
Circuit Overloading .....................................................................................2-3
Reliable Ground ......................................................................................... 2-3
2-5 Rack Mounting Instructions ............................................................................. 2-4
Identifying the Inner Rail and Inner Rail Extension ........................................2-4
Locking Tabs ...................................................................................................2-4
Attaching the Inner Rail .................................................................................. 2-5
Installing the Outer Rails to the Rack ............................................................. 2-6
Chassis Installation .........................................................................................2-8
vi
Table of Contents
Chapter 3 System Interface
3-1 Overview .........................................................................................................3-1
3-2 Control Panel Button .......................................................................................3-1
Power ..............................................................................................................3-1
Chapter 4 Standardized Warning Statements for AC Systems
4-1 About Standardized Warning Statements .......................................................4-1
Warning Defi nition ...........................................................................................4-1
Installation Instructions .................................................................................... 4-4
Circuit Breaker ................................................................................................ 4-5
Power Disconnection Warning ........................................................................ 4-6
Equipment Installation .....................................................................................4-8
Restricted Area ................................................................................................4-9
Battery Handling ............................................................................................ 4-10
Redundant Power Supplies ..........................................................................4-12
Backplane Voltage ........................................................................................ 4-13
Comply with Local and National Electrical Codes ........................................ 4-14
Product Disposal ........................................................................................... 4-15
Hot Swap Fan Warning ................................................................................. 4-16
Power Cable and AC Adapter ......................................................................4-18
Chapter 5 Advanced Serverboard Setup
5-1 Handling the Serverboard ............................................................................... 5-1
Precautions .....................................................................................................5-1
Unpacking .......................................................................................................5-1
5-2 Installing the Processor and Heatsink ............................................................ 5-2
Installing an LGA2011 Processor .................................................................... 5-2
Installing a CPU Heatsink ............................................................................... 5-5
Removing the Heatsink ................................................................................... 5-5
5-3 Connecting Cables .......................................................................................... 5-6
Connecting Data Cables ................................................................................. 5-6
Connecting Power Cables ..............................................................................5-6
5-4 I/O Ports ..........................................................................................................5-6
5-5 Installing Memory ............................................................................................ 5-7
5-6 Adding PCI Cards ......................................................................................... 5-10
5-7 Serverboard Details .......................................................................................5-11
X9DRFF-7TG+/X9DRFF-7G+ Quick Reference ...........................................5-12
5-8 Connector Defi nitions ....................................................................................5-13
5-9 Jumper Settings ............................................................................................5-16
5-10 Onboard Indicators ........................................................................................5-18
vii
SUPERSERVER 6017R-73THDP+/6017R-73HDP+ User's Manual
5-11 SAS/SATA Port Connections ......................................................................... 5-19
5-12 Installing Software ......................................................................................... 5-20
SuperDoctor III .............................................................................................. 5-21
5-13 Onboard Battery ............................................................................................ 5-22
Chapter 6 Advanced Chassis Setup
6-1 Static-Sensitive Devices ..................................................................................6-1
Precautions .....................................................................................................6-1
Unpacking .......................................................................................................6-1
6-2 Removing the Covers .....................................................................................6-2
6-3 System Fans ...................................................................................................6-3
6-4 Drive Bay Installation/Removal .......................................................................6-5
Replacing Hard Drives .................................................................................... 6-5
6-5 Installing Expansion Cards .............................................................................6-7
6-6 Replacing the Power Supply ........................................................................... 6-8
Power Supply Replacement ............................................................................ 6-8
Chapter 7 BIOS
7-1 Introduction ...................................................................................................... 7-1
Starting BIOS Setup Utility .............................................................................. 7-1
How To Change the Confi guration Data .........................................................7-2
Starting the Setup Utility ................................................................................. 7-2
7-2 Main Setup ...................................................................................................... 7-2
7-3 Advanced Setup Confi gurations......................................................................7-4
7-4 Event Logs .................................................................................................... 7-23
7-5 IPMI ............................................................................................................... 7-25
7-6 Boot ............................................................................................................... 7-27
7-7 Secur it y ......................................................................................................... 7-28
7-8 Save & Exit ................................................................................................... 7-29
Appendix A BIOS Error Beep Codes Appendix B System Specifi cations
viii
Chapter 1: Introduction
Chapter 1
Introduction
1-1 Overview
The SuperServer 6017R-73THDP+/6017R-73HDP+ is a high-end server comprised of two main subsystems: the SC816LTS-655B 1U server chassis and the X9DRFF­7TG+/X9DRFF-7G+ dual processor serverboard. Please refer to our web site for information on operating systems that have been certifi ed for use with the system (www.supermicro.com).
In addition to the serverboard and chassis, various hardware components have been included with the 6017R-73THDP+/6017R-73HDP+, as listed below:
Four 4-cm fans (FAN-0065L4)
Four 4-cm fans (FAN-0088L4)
One air shroud (MCP-310-19012-0N)
Two passive CPU heatsinks (SNK-P0047PS)
Riser Card: (see Section 5-6 for details)
One RSC-R1UFF-E8R
SAS/SATA Accessories
Three backplanes (BPN-SAS-816T-A2, BPN-SAS-816T -A4, BPN-SAS-816T -A6)
One rackmount kit (MCP-290-00102-0N)
1-1
SUPERSERVER 6017R-73THDP+/6017R-73HDP+ User's Manual
1-2 Serverboard Features
At the heart of the SuperServer 6017R-73THDP+/6017R-73HDP+ lies the X9DRFF­7TG+/X9DRFF-7G+, a dual processor serverboard based on the Intel® C602 chipset. Below are the main features of the serverboard. (See Figure 1-1 for a block diagram of the chipset.)
Processors
The X9DRFF-7TG+/X9DRFF-7G+ supports single or dual Intel® E5-2600 Series processors in LGA2011 sockets. Please refer to our web site for a complete listing of supported processors (www.supermicro.com).
Memory
The X9DRFF-7TG+/X9DRFF-7G+ has 16 memory sockets that can support up to 512 GB of ECC registered DDR3-1600/1333/1066/800 RDIMMs or up to 128 GB of unbuffered ECC/non-ECC DDR3-1600/1333/1066/800 UDIMMs. Please refer to Chapter 5 for installing memory.
Onboard SAS
An LSI 23 08 SAS controller provides eight SAS2 ports. The SAS drives are con­nected to a backplane that provides power, bus termination and confi guration set- tings. RA ID 0, 1 and 10 are su ppor ted.
Onboard Serial ATA
A SATA controller is integrated into the chipset to provide a six-port SATA subsys­tem. Two of the port s suppo r t SATA 3 .0 and fou r suppo r t SATA 2. 0 (see Chapter 5 for detai ls). RAI D 0, 1, 5 and 10 are suppor ted.
I/O Ports
The color-coded I/O ports located at the front of the server include a VGA (moni­tor) port, two USB 2.0 ports, two 1 Gb Ethernet ports (the X9DRFF-7TG+/6017R­73THDP+ features two 10 Gb Ethernet ports) and one dedicated IPMI LAN port.
Graphics Controller
The X9DRFF-7TG+/X9DRFF-7G+ features an integrated Matrox G200ew, 16 MB DDR2 graphics controller.
1-2
Chapter 1: Introduction
1-3 Server Chassis Features
The 6017R-73THDP+/6017R-73HDP+ is built upon the SC816LTS-655B chassis. Details on the chassis and on servicing procedures can be found in Chapter 6. The following is a general outline of the main features of the chassis.
System Power
The SC816LTS-655B features a single 650W power supply consisting of a single power module. The system must be shut down when replacing or removing this power supply module.
Hard Drives
The SC816LTS-655B chassis was des igned to supp ort 12 SAS/SATA fi xed hard drives, w hich a re mounted i nside t he chas sis.
PCI Expansion Slots
One riser card is included with the system. The RSC-R1UFF-E8R supports one standard size PCI-E 3.0 x8 add-on card. See our web site for details (http://www. supermicro.com/products/nfo/UIO.cfm) and section 5-6 of this manual for details.
Front Control Panel
The chassis' control panel includes a single system power-on button, which also functions as a UID indicator.
Cooling System
The SC816LTS-655B has an innovative cooling design that features four 4-cm counter-rotating fans located in the middle section of the chassis and four 4-cm exhaust fans. The power supply module also includes a cooling fan.
1-3
SUPERSERVER 6017R-73THDP+/6017R-73HDP+ User's Manual
Figure 1-1. Intel C602 Chipset:
System Block Diagram
Note: This is a general block diagram. Please see Chapter 5 for details.
Gen3 x16 x16
SAS2 #1 SAS2 #2 SAS2 #3 SAS2 #4 SAS2 #5 SAS2 #6 SAS2 #7 SAS2 #8
SAS
RJ45
RJ45
PCI-Ex16x16
Proprietary SLOT
SAS2308
I350 (2 ports)
J1
PCI-Ex16
Proprietary SLOT
LAN
X540
J2
Gen3 x8
#1
#2
E
DDR3 DIMM
#1
#2
C
DDR3 DIMM
Gen3 x8 (0~7)
J3
J4
PCI-Ex8 SLOT
PCI-Ex8 SLOT
PCI-Ex4 in x8 SLOT
#1
#2
F
DDR3 DIMM
#1
#2
D
DDR3 DIMM
Gen3 x16
Gen3 x8 (8~15)
Gen3 x8 (0~7)
Gen2 x4
PE2
PE1 DMI
E5-2600 Series Processor
E5-2600 Series Processor
PE1
PE3
CPU1
Rear (Fan Side)
P0 P1
QPI
P1 P0
CPU0
Front (I/O Side)
PE2
PE3
QPI
DMI
Gen2 x4
DMI
PEG2_5:7
PEG2_0:4
DDR2
#1
#2
H
DDR3 DIMM
#1
#2
B
DDR3 DIMM
AT25321
SPI
PCH C602
WPCM450
VGA BMC
G
A
SATA
AHCI
LPCPCI-32bit
#1
#2
DDR3 DIMM
#1
#2
DDR3 DIMM
6/3/1.5 6/3/1.5
SCU
USB
3/1.5 3/1.5 3/1.5 3/1.5
SATA
USB
TPM
SATA2 #6 SATA2 #5 SATA2 #4 SATA2 #3 SATA3 #2 SATA3 #1
SATA2 #1 DOM
01 2
Single
Single
Type A
1-4
VGA CONN
PHY RTL8201F
LAN
1-4 Contacting Supermicro
Headquarters
Address: Super Micro Computer, Inc.
980 Rock Ave.
San Jose, CA 95131 U.S.A. Tel: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: marketing@supermicro.com (General Information)
support@supermicro.com (Technical Support)
Chapter 1: Introduction
Web Site:
Europe
Address: Super Micro Computer B.V.
Tel: +31 (0) 73-6400390 Fax: +31 (0) 73-6416525 Email: sales@supermicro.nl (General Information)
Asia-Pacifi c
Address: Super Micro Computer, Inc.
www.supermicro.com
Het Sterrenbeeld 28, 5215 ML
's-Hertogenbosch, The Netherlands
support@supermicro.nl (Technical Support)
rma@supermicro.nl (Customer Support)
3F, No. 150, Jian 1st Rd.
Zhonghe Dist., New Taipei City 23511
Taiwan (R.O.C) Tel: +886-(2) 8226-3990 Fax: +886-(2) 8226-3992 Web Site: Technical Support: Email: support@supermicro.com.tw Tel: +886-(2)-8226-3990
www.supermicro.com.tw
1-5
SUPERSERVER 6017R-73THDP+/6017R-73HDP+ User's Manual
Notes
1-6
Chapter 2: Server Installation
Chapter 2
Server Installation
2-1 Overview
This chapter provides a quick setup checklist to get your SuperServer 6017R­73THDP+/6017R-73HDP+ up and running. Following the steps in the order given should enable you to have the system operational within a minimal amount of time. This quick setup assumes that your system has come to you with the processor and memory preinstalled. If your system is not already fully integrated with a mother­board, processor, system memory etc., please turn to the chapter or section noted in each step for details on installing specifi c components.
2-2 Unpacking the System
You should inspect the box the server was shipped in and note if it was damaged in any way. If the server itself shows damage, you should fi le a damage claim with the carrier who delivered it.
Decide on a suitable location for the rack unit that will hold the server. It should be situated in a clean, dust-free area that is well ventilated. Avoid areas where heat, electrical noise and electromagnetic fi elds are generated. You will also need it placed near a grounded power outlet. Read the Rack and Server Precautions in the next section.
2-3 Preparing for Setup
The box the SuperServer 6017R-73THDP+/6017R-73HDP+ was shipped in should include two sets of rail assemblies, six rail mounting brackets and the mounting screws you will need to install the system into the rack. Follow the steps in the order given to complete the installation process in a minimal amount of time. Please read this section in its entirety before you begin the installation procedure outlined in the sections that follow.
Choosing a Setup Location
Leave enough clearance in front of the rack to enable you to open the front door
completely (~25 inches) and approximately 30 inches of clearance in the back of the rack to allow for suffi cient airfl ow and ease in servicing.This product is for
2-1
SUPERSERVER 6017R-73THDP+/6017R-73HDP+ User's Manual
installation only in a Restricted Access Location (dedicated equipment rooms, service closets and the like).
This product is not suitable for use with visual display work place devices
acccording to §2 of the the German Ordinance for Work with Visual Display Units.
2-4 Warnings and Precautions
Rack Precautions
Ensure that the leveling jacks on the bottom of the rack are fully extended to
the fl oor with the full weight of the rack resting on them.
In single rack installation, stabilizers should be attached to the rack. In multiple
rack installations, the racks should be coupled together.
Always make sure the rack is stable before extending a component from the
rack.
You should extend only one component at a time - extending two or more si-
multaneously may cause the rack to become unstable.
Server Precautions
Review the electrical and general safety precautions in Chapter 4.
Determine the placement of each component in the rack before you install the
rails.
Install the heaviest server components on the bottom of the rack fi rst, and then
work up.
Use a regulating uninterruptible power supply (UPS) to protect the server from
power surges, voltage spikes and to keep your system operating in case of a power failure.
Allow the hot plug SATA drives and power supply modules to cool before touch-
ing them.
Always keep the rack's front door and all panels and components on the servers
closed when not servicing to maintain proper cooling.
2-2
Chapter 2: Server Installation
Rack Mounting Considerations
Ambient Operating Temperature
If installed in a closed or multi-unit rack assembly, the ambient operating tempera­ture of the rack environment may be greater than the ambient temperature of the room. Therefore, consideration should be given to installing the equipment in an environment compatible with the manufacturer’s maximum rated ambient tempera­ture (Tmra).
Reduced Airfl ow
Equipment should be mounted into a rack so that the amount of airfl ow required for safe operation is not compromised.
Mechanical Loading
Equipment should be mounted into a rack so that a hazardous condition does not arise due to uneven mechanical loading.
Circuit Overloading
Consideration should be given to the connection of the equipment to the power supply circuitry and the effect that any possible overloading of circuits might have on overcurrent protection and power supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.
Reliable Ground
A reliable ground must be maintained at all times. To ensure this, the rack itself should be grounded. Particular attention should be given to power supply connec­tions other than the direct connections to the branch circuit (i.e. the use of power strips, etc.).
Warning! To prevent bodily injury when mounting or servicing this unit in a rack, you must take special precautions to ensure that the system remains stable. The following guidelines are provided to ensure your safety:
This unit should be mounted at the bottom of the rack if it is the only unit in
the rack.
When mounting this unit in a partially fi lled rack, load the rack from the bottom
to the top with the heaviest component at the bottom of the rack.
If the rack is provided with stabilizing devices, install the stabilizers before
mounting or servicing the unit in the rack.
2-3
SUPERSERVER 6017R-73THDP+/6017R-73HDP+ User's Manual
2-5 Rack Mounting Instructions
This section provides information on installing the chassis into a rack unit with the rails provided. There are a variety of rack units on the market, which may mean that the assembly procedure will differ slightly from the instructions provided. You should also refer to the installation instructions that came with the rack unit you are using. NOTE: This rail will fi t a rack between 26.5" and 36.4" deep.
Identifying the Inner Rail and Inner Rail Extension
The SC816LT chassis includes mounting rails for installing the system into a rack. Each assembly consists of two sections: An inner rail which is pre-installed on the chassis, an inner rail extension, and an outer rail that secures to the rack. These assemblies are specifi cally designed for the left and right side of the chassis
Locking Tabs
Each inner rail has a locking tab. This tab locks the chassis into place when installed and pushed fully into the rack. These tabs also lock the chassis in place when fully extended from the rack. This prevents the server from coming completely out of the rack when when the chassis is pulled out for servicing.
Inner Rail
Extension
Inner Rail
Three
Screws
Three
Screws
Figure 2-1. Identifying the Inner Rails and Inner Rail Extensions
Locking Tab
2-4
Chapter 2: Server Installation
Attaching the Inner Rail
The SC816LT chassis ships with the inner rails already installed. In most cases it is only necessary to install the inner rail extention.
Releasing Inner Rail from the Outer Rails
1. Identify the left and right inner rails and inner rail extensions as illustrated in Figure 6-1.
2. Place the inner rail and inner rail extension against the side of the chassis.
3. Slide the inner rail and inner rail extension forward toward the front of the chassis
4. Secure the inner rail and inner rail extension with three screws.
5. Repeat steps 1-4 with the remaining inner rail.
1
4
1
2
1
3
Figure 2-2. Attaching the Inner Rail and Inner Rail Extension
Warning: do not pick up the server with the front handles. They are de-
signed to pull the system from a rack only.
1
2
2-5
SUPERSERVER 6017R-73THDP+/6017R-73HDP+ User's Manual
Flat head
M5 x 12 mm [0.472]
Washer for M5
Secure to the
Rear of the Rack
Attach Outer Rack Rails
Together
Secure to the
Front of the Rack
Figure 2-3. Assembling the Outer Rails
Installing the Outer Rails to the Rack
Installing the Outer Rails
1. Attach the short bracket to the outside of the long bracket. You must align the pins with the slides. Also, both bracket ends must face the same direction.
2-6
Chapter 2: Server Installation
Figure 2-4. Attaching the Outer Rails to a Rack
2. Adjust both the short and long brackets to the proper distance so that the rail ts snugly into the rack.
3. Secure the long bracket to the front side of the outer rail with two M5 screws and the short bracket to the rear side of the outer rail with three M5 screws. Use a washer with each screw.
4. Repeat steps 1-4 for the remaining outer rail.
Stability hazard. The rack stabilizing mechanism must be in place, or the rack must be bolted to the fl oor before you slide the unit out for servicing. Failure to stabilize the rack can cause the rack to tip over.
2-7
SUPERSERVER 6017R-73THDP+/6017R-73HDP+ User's Manual
1
3
Figure 2-5. Installing the Chassis into a Rack
Note: gures are for illustrative purposes only. Always install servers into racks
from the bottom up.
Chassis Installation
Installing the Chassis into a Rack
1. Confi rm that the rails are correctly installed on the rack.
2. Align the guides on the chassis with the front of the rails.
3. Slide the guides of the chassis into the rails, keeping the pressure even on both sides, until the locking tabs click into place, securing chassis in a fully extended position.
4. Simultaneously depress the locking tabs of both rails at the same time and push the chassis all the way into the rack.
5. If necessary, use screws to secure the chassis handles to the front of the rack.
2-8
Chapter 3: System Interface
Chapter 3
System Interface
3-1 Overview
The server chassis has a single power on/off button. No other buttons or indicators are needed on the Hadoop server.
3-2 Control Panel Button
The power on/off button is located just to the right of the COM port on the front of the chassis.
Power
The main power button is used to apply or remove power from the power supply to the system. Turning off system power with this button removes the main power, but keeps standby power supplied to the system. For this reason, you should unplug the system before servicing. The power button has a built-in LED that will turn green when the power is on.
3-1
SUPERSERVER 6017R-73THDP+/6017R-73HDP+ User's Manual
Notes
3-2
Chapter 4: Warning Statements for AC Systems
Chapter 4
Standardized Warning Statements for AC Systems
4-1 About Standardized Warning Statements
The following statements are industry standard warnings, provided to warn the user of situations which have the potential for bodily injury. Should you have questions or experience difficulty, contact Supermicro's Technical Support department for assistance. Only certifi ed technicians should attempt to install or confi gure components.
Read this appendix in its entirety before installing or confi guring components in the Supermicro chassis.
These warnings may also be found on our web site at http://www.supermicro.com/ about/policies/safety_information.cfm.
Warning Defi nition
Warning!
This warning symbol means danger. You are in a situation that could cause bodily injury. Before you work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents.
警告の定義
この警告サインは危険を意味します。
人身事故につながる可能性がありますので、いずれの機器でも動作させる前に、
電気回路に含まれる危険性に注意して、標準的な事故防止策に精通して下さい。
此警告符号代表危险。
您正处于可能受到严重伤害的工作环境中。在您使用设备开始工作之前,必须充分 意识到触电的危险,并熟练掌握防止事故发生的标准工作程序。请根据每项警告结 尾的声明号码找到此设备的安全性警告说明的翻译文本。
此警告符號代表危險。
您正處於可能身體可能會受損傷的工作環境中。在您使用任何設備之前,請注意觸 電的危險,並且要熟悉預防事故發生的標準工作程序。請依照每一注意事項後的號 碼找到相關的翻譯說明內容。
4-1
SUPERSERVER 6017R-73THDP+/6017R-73HDP+ User's Manual
ןונקת תורהצהאהרהז
Warnung WICHTIGE SICHERHEITSHINWEISE Dieses Warnsymbol bedeutet Gefahr. Sie befi nden sich in einer Situation, die zu
Verletzungen führen kann. Machen Sie sich vor der Arbeit mit Geräten mit den Gefahren elektrischer Schaltungen und den üblichen Verfahren zur Vorbeugung vor Unfällen vertraut. Suchen Sie mit der am Ende jeder Warnung angegebenen Anweisungsnummer nach der jeweiligen Übersetzung in den übersetzten Sicherheitshinweisen, die zusammen mit diesem Gerät ausgeliefert wurden.
BEWAHREN SIE DIESE HINWEISE GUT AUF.
INSTRUCCIONES IMPORTANTES DE SEGURIDAD Este símbolo de aviso indica peligro. Existe riesgo para su integridad física. Antes
de manipular cualquier equipo, considere los riesgos de la corriente eléctrica y familiarícese con los procedimientos estándar de prevención de accidentes. Al nal de cada advertencia encontrará el número que le ayudará a encontrar el texto traducido en el apartado de traducciones que acompaña a este dispositivo.
GUARDE ESTAS INSTRUCCIONES.
IMPORTANTES INFORMATIONS DE SÉCURITÉ Ce symbole d'avertissement indique un danger. Vous vous trouvez dans une
situation pouvant entraîner des blessures ou des dommages corporels. Avant de travailler sur un équipement, soyez conscient des dangers liés aux circuits électriques et familiarisez-vous avec les procédures couramment utilisées pour éviter les accidents. Pour prendre connaissance des traductions des avertissements gurant dans les consignes de sécurité traduites qui accompagnent cet appareil, référez-vous au numéro de l'instruction situé à la fi n de chaque avertissement.
CONSERVEZ CES INFORMATIONS.
ןה תואבה תורהצהא ינפמ שמתשמה תא ריהזהל תנמ לע ,היישעתה ינקת יפ לע תורהז הלבח
ה וא תולאש שיו הדימב .תירשפא תיזיפי ,יהשלכ היעבב תולקתרוציל שי הכימת תקלחמ םע רשק
רידגהל וא ןיקתהל םיאשר דבלב םיכמסומ םיאנכט .ורקימרפוס לש תינכט תאה .םיביכר
תרדגה וא תנקתה ינפל ואולמב חפסנה תא
אורקל שי .ורקימרפוס יזראמב םיביכרה
4-2
Warning Statements for AC Systems
. ﻲﻓ ﻚﻧﺍ ﻥﺃ ﻦﻜﻤﻳ ﺔﻟﺎﺣ ﻲﻓ ﺐﺒﺴﺘﺗ ﺔﺑﺎﺻﺍ ﺔﻳﺪﺴﺟ ﺰﻣﺮﻟﺍ ﺍﺬﻫ ﻲﻨﻌﻳ ﺮﻄﺧ !ﺮﻳﺬﺤﺗ
ﻥﺃ ﻞﺒﻗ ﻱﺃ ﻰﻠﻋ ﻞﻤﻌﺗ ﺕﺍﺪﻌﻣ،ﻢﻠﻋ ﻰﻠﻋ ﻦﻋ ﺔﻤﺟﺎﻨﻟﺍ ﺮﻁﺎﺨﻤﻟﺎﺑ ﺮﺋﺍﻭﺪﻟﺍ
ﺔﻴﺋﺎﺑﺮﻬﻜﻟﺍ
ﻛﻭﺔﻳﺍﺭﺩ ﻰﻠﻋ ﻦ ﺭﺎﻤﻤﻟﺎﺑﺕﺎﺳ ﺔﻴﺋﺎﻗﻮﻟﺍ ﻊﻨﻤﻉﻮﻗﻭ ﻱﺃﺙﺩﺍﻮﺣ
ﻢﻗﺭ ﻡﺪﺨﺘﺳﺍ ﻥﺎﻴﺒﻟﺍ ﺹﻮﺼﻨﻤﻟﺍ ﺔﻳﺎﻬﻧ ﻲﻓ ﺮﻳﺬﺤﺗ ﻞﻛ ﺭﻮﺜﻌﻠﻟ ﺎﻬﺘﻤﺟﺮﺗ
안전을 위한 주의사항
경고!
이 경고 기호는 위험이 있음을 알려 줍니다. 작업자의 신체에 부상을 야기 할 수 있는 상태에 있게 됩니다. 모든 장비에 대한 작업을 수행하기 전에 전기회로와 관련된 위험요소들을 확인하시고 사전에 사고를 방지할 수 있도록 표준 작업절차를 준수해 주시기 바랍니다.
해당 번역문을 찾기 위해 각 경고의 마지막 부분에 제공된 경고문 번호를 참조하십시오
BELANGRIJKE VEILIGHEIDSINSTRUCTIES Dit waarschuwings symbool betekent gevaar. U verkeert in een situatie die
lichamelijk letsel kan veroorzaken. Voordat u aan enige apparatuur gaat werken, dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico's en dient u op de hoogte te zijn van de standaard procedures om ongelukken te voorkomen. Gebruik de nummers aan het eind van elke waarschuwing om deze te herleiden naar de desbetreffende locatie.
BEWAAR DEZE INSTRUCTIES
4-3
SUPERSERVER 6017R-73THDP+/6017R-73HDP+ User's Manual
Installation Instructions
Warning!
Read the installation instructions before connecting the system to the power source.
設置手順書
システムを電源に接続する前に、設置手順書をお読み下さい。
警告 将此系统连接电源前,请先阅读安装说明。
警告 將系統與電源連接前,請先閱讀安裝說明。
Warnung Vor dem Anschließen des Systems an die Stromquelle die Installationsanweisungen
lesen.
¡Advertencia! Lea las instrucciones de instalación antes de conectar el sistema a la red de
alimentación.
Attention Avant de brancher le système sur la source d'alimentation, consulter les directives
d'installation.
אורקל שי רוקמל תכרעמה רוביח ינפל הנקתה תוארוה תאחתמ.
ﻟﺍ ﺕﺍﺩﺎﺷﺭﺇ ﺮﻗﺍﺐﻴﻛﺮﺘ ﻞﻴﺻﻮﺗ ﻞﺒﻗ ﻰﻟﺇ ﻡﺎﻈﻨﻟﺍ ﺔﻗﺎﻄﻠﻟ ﺭﺪﺼﻣ
시스템을 전원에 연결하기 전에 설치 안내를 읽어주십시오.
Waarschuwing Raadpleeg de installatie-instructies voordat u het systeem op de voedingsbron
aansluit.
4-4
Chapter 4: Warning Statements for AC Systems
Circuit Breaker
Warning!
This product relies on the building's installation for short-circuit (overcurrent) protection. Ensure that the protective device is rated not greater than: 250 V, 20 A.
サーキット・ブレーカー
この製 品 は、短絡(過電流)保護装置がある建物での設置を前提としています。
保護装置の定格が250V、20Aを超えないことを確認下さい。
警告 此产品的短路(过载电流)保护由建筑物的供电系统提供,确保短路保护设备的额定电 流不大于250V,20A。
警告 此產品的短路(過載電流)保護由建築物的供電系統提供,確保短路保護設備的額定電 流不大於250V,20A。
Warnung Dieses Produkt ist darauf angewiesen, dass im Gebäude ein Kurzschluss-
bzw. Überstromschutz installiert ist. Stellen Sie sicher, dass der Nennwert der Schutzvorrichtung nicht mehr als: 250 V, 20 A beträgt.
¡Advertencia! Este equipo utiliza el sistema de protección contra cortocircuitos (o sobrecorrientes)
del edifi cio. Asegúrese de que el dispositivo de protección no sea superior a: 250 V, 20 A.
Attention Pour ce qui est de la protection contre les courts-circuits (surtension), ce produit
dépend de l'installation électrique du local. Vérifi ez que le courant nominal du dispositif de protection n'est pas supérieur à :250 V, 20 A.
ﺞﺘﻨﻤﻟﺍ ﺍﺬﻫ ﻰﻠﻋ ﺪﻤﺘﻌﻳ ﺕﺍﺪﻌﻣ ﺔﻳﺎﻤﺤﻟﺍ ﺓﺮﻴﺼﻘﻟﺍﺮﺋﺍﻭﺪﻟﺍ ﻦﻣ ﺎﻬﺘﻴﺒﺜﺗ ﻢﺗ ﻲﺘﻟﺍ ﻲﻓ
לע ךמתסמ הז רצומנגהה תעינמל םינבמב תנקתומה יכ אדוול שי .ילמשח רצק
רצקה ינפמ ןגמה רישכמה ילמשחהמ רתוי אל אוה-250 V, 20 A
ﻰﻨﺒﻤﻟﺍ
20A, 250V : ﻦﻣ ﺪﻛﺄﺗ ﻥﺃ ﻢﻴﻴﻘﺗ ﺯﺎﻬﺠﻟﺍ ﻟﺍﻲﺋﺎﻗﻮ ﺲﻴﻟ ﻦﻣ ﺮﺜﻛﺃ
4-5
SUPERSERVER 6017R-73THDP+/6017R-73HDP+ User's Manual
경고!
이 제품은 전원의 단락(과전류)방지에 대해서 전적으로 건물의 관련 설비에 의존합니다. 보호장치의 정격이 반드시 250V(볼트), 20A(암페어)를 초과하지 않도록 해야 합니다.
Waarschuwing Dit product is afhankelijk van de kortsluitbeveiliging (overspanning) van
uw electrische installatie. Controleer of het beveiligde aparaat niet groter gedimensioneerd is dan 220V, 20A.
Power Disconnection Warning
Warning!
The system must be disconnected from all sources of power and the power cord removed from the power supply module(s) before accessing the chassis interior to install or remove system components.
電源切断の警告 システムコンポーネントの取り付けまたは取り外しのために、シャーシー内部にアクセス
するには、 システムの電源はすべてのソースから切断され、電源コードは電源モジュールから取り
外す必要があります。
警告
在你打开机箱并安装或移除内部器件前,必须将系统完全断电,并移除电源线。
警告
在您打開機殼安裝或移除內部元件前,必須將系統完全斷電,並移除電源線。
Warnung Das System muss von allen Quellen der Energie und vom Netzanschlusskabel
getrennt sein, das von den Spg.Versorgungsteilmodulen entfernt wird, bevor es auf den Chassisinnenraum zurückgreift, um Systemsbestandteile anzubringen oder zu entfernen.
4-6
Loading...
+ 80 hidden pages