Supero SC510 Series, SC510-200B User Manual

Page 1
SC510 Chassis Series
SC510-200B
SUPER
®
USER’S MANUAL
1.0
Page 2
SC510-200B Chassis Manual
Manual Revision 1.0 Release Date: November 16, 2007
The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccuracies that may be contained in this document, makes no commitment to update or to keep current the information in this manual, or to notify any person or organization of the updates. Please Note: For the most up-to-date version of this
manual, please see our web site at www.supermicro.com.
Super Micro Computer, Inc. ("Supermicro") reserves the right to make changes to the product described in this manual at any time and without notice. This product, including software, if any, and documentation may not, in whole or in part, be copied, photocopied, reproduced, translated or reduced to any medium or machine without prior written consent.
IN NO EVENT WILL SUPERMICRO BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL, SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO USE THIS PRODUCT OR DOCUMENTATION, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. IN PARTICULAR, SUPERMICRO SHALL NOT HAVE LIABILITY FOR ANY HARDWARE, SOFTWARE, OR DATA STORED OR USED WITH THE PRODUCT, INCLUDING THE COSTS OF REPAIRING, REPLACING, INTEGRATING, INSTALLING OR RECOVERING SUCH HARDWARE, SOFTWARE, OR DATA.
Any disputes arising between manufacturer and customer shall be governed by the laws of Santa Clara County in the State of California, USA. The State of California, County of Santa Clara shall be the exclusive venue for the resolution of any such disputes. Super Micro's total liability for all claims will not exceed the price paid for the hardware product.
WARNING: Handling of lead solder materials used in this product may expose you to lead, a chemical known to the State of California to cause birth defects and other reproductive harm.
Unless you request and receive written permission from Super Micro Computer, Inc., you may not copy any part of this document.
Information in this document is subject to change without notice. Other products and companies referred to herein are trademarks or registered trademarks of their respective companies or mark holders.
Copyright © 2007 by Super Micro Computer, Inc. All rights reserved.
Printed in the United States of America
Page 3
iii
Preface
Preface
About This Manual
This manual is written for professional system integrators and PC technicians. It
provides information for the installation and use of the SC510 chassis. Installation
and maintenance should be performed by experienced technicians only.
Supermicro’s SC510-200B chassis features a unique and highly-optimized design
for dual-core Intel Xeon 300/Core 2 Duo platforms. The chassis is equipped with
a 200W high efficiency power supply for superb power savings. High performance
fans provide ample optimized cooling.
This document lists compatible parts available when this document was published.
Always refer to the our Web site
for updates on supported parts and configura-
tions.
Page 4
iv
Manual Organization
Chapter 1 Introduction
The first chapter provides a checklist of the main components included with this chassis and describes the main features of the SC510-200B chassis. This chapter
also includes contact information.
Chapter 2 System Safety
This chapter lists warnings, precautions, and system safety. It recommended that
you thoroughly familiarize yourself installing and servicing this chassis safety pre-
cautions.
Chapter 3 Chassis Components
Refer here for details on this chassis model including the fans, airflow shields, and
other components.
Chapter 4 Chassis Setup and Installation
Follow the procedures given in this chapter when installing, removing, or
reconfiguring your chassis.
Chapter 5 Rack Installation
Refer to this chapter for detailed information on chassis rack installation. You should
follow the procedures given in this chapter when installing, removing or reconfiguring
your chassis into a rack environment.
Appendix A Chassis Hardware
Appendix B: Power Supply Specifications
SC510 Chassis Manual
Page 5
v
Preface
Table of Contents
Chapter 1 Introduction
1-1 Overview ......................................................................................................... 1-1
1-2 Shipping List .................................................................................................... 1-
1
Part Numbers .................................................................................................. 1-
1
1-3 Where to get Replacement Components ........................................................ 1-2
1-4 Contacting SuperMicro .................................................................................... 1-
3
Chapter 2 System Safety
2-1 Overview ......................................................................................................... 2-1
2-2 Warnings and Precautions .............................................................................. 2-
1
2-3 Preparing for Setup ......................................................................................... 2-1
2-4 Electrical Safety Precautions .......................................................................... 2-2
2-5 General Safety Precautions ............................................................................ 2-3
2-6 System Safety ................................................................................................. 2-3
Chapter 3 Chassis Components
3-1 Overview ......................................................................................................... 3-1
3-2 Components .................................................................................................... 3-1
Chassis ............................................................................................................ 3-
1
Fans ................................................................................................................ 3-1
Mounting to a Rack (optional
) ......................................................................... 3-2
Power Supply .................................................................................................. 3-2
Air Shroud ....................................................................................................... 3-
2
3-3 Where to get Replacement Components ........................................................ 3-2
Chapter 4 Chassis Setup and Maintenance
4-1 Overview ......................................................................................................... 4-1
4-2 Removing the Chassis Cover ......................................................................... 4-2
4-3 Installing the Hard Drives ................................................................................ 4-3
4-4 Installing the Motherboard .............................................................................. 4-4
Permanent and Optional Standoffs ................................................................. 4-
4
Installing the Motherboard
: ............................................................................. 4-5
Add-on Card/Expansion
Slot Setup ................................................................ 4-6
4-5 Replacing the Heatsink ................................................................................... 4-7
4-6 Installing the Air Shroud .................................................................................. 4-8
Checking the Server's Air
Flow ....................................................................... 4-9
4-7 Replacing System Fans ................................................................................ 4-10
4-8 Power Supply ............................................................................................... 4-12
Replacing the Power Supply ......................................................................... 4-1
2
Page 6
vi
Chapter 5 Rack Installatio
n
5-1 Overview ......................................................................................................... 5-1
5-2 Unpacking the System .................................................................................... 5-1
5-3 Preparing for Setup ......................................................................................... 5-1
Choosing a Setup Location ............................................................................. 5-
1
Rack Precautions ............................................................................................ 5-
2
General Server Precautions ............................................................................ 5-
2
Rack Mounting Considerations ....................................................................... 5-
3
Ambient Operating Temperature ................................................................ 5-
3
Reduced Airflow ......................................................................................... 5-
3
Mechanical Loading ................................................................................... 5-
3
Circuit Overloading ..................................................................................... 5-
3
5-4 Rack Mounting Instructions ............................................................................. 5-4
Installing the Chassis into a Rack: ................................................................. 5-
4
Appendix A Cables, Screws, and other Accessories
Appendix
B SC510 Power Supply Specifications
Page 7
Chapter 1
Introduction
1-1 Overview
Supermicro’s SC510-200B chassis features a unique and highly-optimized design.
The chassis is equipped with high efficiency 80%+ low noise power supply.
1-2 Shipping List
Part Numbers
Please visit the following link for the latest shiping lists and part numbers for your
particular chassis model http://www.supermicro.com/
Chapter 1: Introduction
1-1
SC510-200B Chassis
Model CPU HDD I/O Slots
Power
Supply
SC510-200(B)
Intel Xeon 3000/
Core 2 Duo
Series
1 Fixed 3.5"
hard drive or
up to 4 fixed
2.5" hard drives
1x FH
(optional)
200W
Page 8
SC510 Chassis Manual
1-2
1-3 Where to get Replacement Components
Though not frequently, you may need replacement parts for your system. To en-
sure the highest level of professional service and technical support, we strongly
recommend purchasing exclusively from our Supermicro Authorized Distributors /
System Integrators / Resellers. A list of Supermicro Authorized Distributors / Sys-
tem Integrators /Reseller can be found at: http://www.supermicro.com. Click the
Where to Buy link.
Page 9
1-3
Chapter 1: Introduction
1-4 Contacting SuperMicro
Headquarters
Address: Super Micro Computer, Inc.
980 Rock Ave.
San Jose, CA 95131 U.S.A.
Tel: +1 (408) 503-8000
Fax: +1 (408) 503-8008
Email: marketing@supermicro.com (General Information)
support@supermicro.com (Technical Support)
Web Site: www.supermicro.com
Europe
Address: Super Micro Computer B.V.
Het Sterrenbeeld 28, 5215 ML
's-Hertogenbosch, The Netherlands
Tel: +31 (0) 73-6400390
Fax: +31 (0) 73-6416525
Email: sales@supermicro.nl (General Information)
support@supermicro.nl (Technical Support)
rma@supermicro.nl (Customer Support)
Asia-Pacific
Address: Super Micro Computer, Taiwan
4F, No. 232-1, Liancheng Rd.
Chung-Ho 235, Taipei County
Taiwan, R.O.C.
Tel: +886-(2) 8226-3990
Fax: +886-(2) 8226-3991
Web Site: www.supermicro.com.tw
Email: support@supermicro.com.tw (Technical Support)
Tel: 886-2-8228-1366, ext.132 or 139
Page 10
SC510 Chassis Manual
1-4
Notes
Page 11
2-1
Chapter 2: System Safety
Chapter 2
System Safety
2-1 Overview
This chapter provides a quick setup checklist to get your chassis up and running.
Following the steps in order given should enable you to have your chassis setup and
operational within a minimal amount of time. This quick set up assumes that you
are an experienced technician, famailiar with common concepts and terminology.
2-2 Warnings and Precautions
You should inspect the box the chassis was shipped in and note if it was damaged
in any way. If the chassis itself shows damage, file a damage claim with carrier
who delivered your system.
Decide on a suitable location for the rack unit that will hold that chassis. It should
be situated in a clean, dust-free area that is well venilated. Avoid areas where heat,
electrical noise and eletromagnetic fields are generated.
You will also need it placed near at least one grounded power outlet. When config
-
ured, the SC510-200B chassis includes one power supply.
2-3 Preparing for Setup
The SC510-200B Chassis bolts directly to a rack and includes the mounting screws
you will need to install the systems into the rack. Please read this manual in its
entirety before you begin the installation procedure.
Page 12
SC510 Chassis Manual
2-2
2-4 Electrical Safety Precautions
Basic electrical safety precautions should be followed to protect yourself from harm
and the SC510-200B from damage:
Be aware of the locations of the power on/off switch on the chassis as well
as the room’s emergency power-off switch, disconnection switch or electrical
outlet. If an electrical accident occurs, you can then quickly remove power from
the system.
Do not work alone when working with high voltage components.
Power should always be disconnected from the system when removing or in
-
stalling main system components, such as the serverboard, memory modules
and the DVD-ROM and floppy drives (not necessary for hot swappable drives).
When disconnecting power, you should first power down the system with the
operating system and then unplug the power cords from all the power supply
modules in the system.
When working around exposed electrical circuits, another person who is fa
-
miliar with the power-off controls should be nearby to switch off the power, if
necessary.
Use only one hand when working with powered-on electrical equipment. This
is to avoid making a complete circuit, which will cause electrical shock. Use
extreme caution when using metal tools, which can easily damage any electrical
components or circuit boards they come into contact with.
Do not use mats designed to decrease electrostatic discharge as protection from
electrical shock. Instead, use rubber mats that have been specifically designed
as electrical insulators.
The power supply power cord must include a grounding plug and must be
plugged into grounded electrical outlets.
Serverboard Battery: CAUTION - There is a danger of explosion if the onboard
battery is installed upside down, which will reverse its polarities This battery
must be replaced only with the same or an equivalent type recommended by
the manufacturer. Dispose of used batteries according to the manufacturer’s
instructions.
Page 13
2-3
Chapter 2: System Safety
DVD-ROM Laser: CAUTION - this server may have come equipped with a
DVD-ROM drive. To prevent direct exposure to the laser beam and hazardous
radiation exposure, do not open the enclosure or use the unit in any uncon-
ventional way.
2-5 General Safety Precautions
Keep the area around the chassis clean and free of clutter.
Place the chassis top cover and any system components that have been re
-
moved away from the system or on a table so that they won’t accidentally be
stepped on.
While working on the system, do not wear loose clothing such as neckties and
unbuttoned shirt sleeves, which can come into contact with electrical circuits or
be pulled into a cooling fan.
Remove any jewelry or metal objects from your body, which are excellent metal
conductors that can create short circuits and harm you if they come into contact
with printed circuit boards or areas where power is present.
After accessing the inside of the system, close the system back up and secure
it to the rack unit with the retention screws after ensuring that all connections
have been made.
2-6 System Safety
Electrostatic discharge (ESD) is generated by two objects with different electrical
charges coming into contact with each other. An electrical discharge is created to
neutralize this difference, which can damage electronic components and printed
circuit boards. The following measures are generally sufficient to neutralize this
difference before contact is made to protect your equipment from ESD:
Do not use mats designed to decrease electrostatic discharge as protection from
electrical shock. Instead, use rubber mats that have been specifically designed
as electrical insulators.
Use a grounded wrist strap designed to prevent static discharge.
Keep all components and printed circuit boards (PCBs) in their antistatic bags
until ready for use.
Page 14
SC510 Chassis Manual
2-4
Touch a grounded metal object before removing any board from its antistatic
bag.
Do not let components or PCBs come into contact with your clothing, which may
retain a charge even if you are wearing a wrist strap.
Handle a board by its edges only; do not touch its components, peripheral chips,
memory modules or contacts.
When handling chips or modules, avoid touching their pins.
Put the serverboard and peripherals back into their antistatic bags when not
in use.
For grounding purposes, make sure your computer chassis provides excellent
conductivity between the power supply, the case, the mounting fasteners and
the serverboard.
Page 15
3-1
Chapter 3: Chassis Components
Chapter 3
Chassis Components
3-1 Overview
This chapter describes the most common components included with your chassis.
Some components listed may not be included or compatible with your particular
chassis model. For more information, see the installation instructions detailed later
in this manual.
3-2 Components
Chassis
Chassis may include one of the following three options:
One fixed 3.5" hard drive.
Up to 4 fixed 2.5" hard drives.
One FH PCI add-on card
For the latest shipping lists, visit our Web site at: http://www.supermicro.com.
This chassis accepts two system cooling fans and one power supply.
SC510-200B
models come in black.
Fans
The SC510-200B chassis accepts two system fans. System fans for SC510-
200B
chassis are powered from the serverboard. These fans are 1U high and are
powered by 3-pin or 4-pin connectors.
Page 16
SC510 Chassis Manual
3-2
Mounting to a Rack (optional)
The SC510-200B can be placed in a rack for secure storage and use. To setup
your rack, follow the step-by-step instructions included in this manual.
Power Supply
Each SC510-200B chassis model includes a high-efficiency 80%+ low noise power
supply with thermal control fan, rated at 200 Watts. In the unlikely event your power
supply fails, replacement is simple. The power supply simply needs to be unscrewed
from the chassis and replaced.
Air Shroud
Air shrouds are shields, usually plastic, that funnel air directly to where it is needed.
Always use the air shroud included with your chassis.
3-3 Where to get Replacement Components
Though not frequently, you may need replacement parts for your system. To en-
sure the highest level of professional service and technical support, we strongly
recommend purchasing exclusively from our Supermicro Authorized Distributors/
System Integrators/Resellers. A list of Supermicro Authorized Distributors/System
Integrators/Resellers can be found at: http://www.supermicro.com. Click the Where
to Buy link.
Page 17
4-1
Chapter 4: Chassis Setup and Maintenance
Chapter 4
Chassis Setup and Maintenance
4-1 Overview
This chapter covers the steps required to install components and perform mainte-
nance on the chassis. The only tool you will need to install components and perform
maintenance is a Phillips screwdriver. Print this page to use as a reference while
setting up your chassis.
Review the warnings and precautions listed in the manual be
­fore setting up or servicing this chassis. These include infor­mation in Chapter 2: System Safety and the warning/precau
­tions listed in the setup instructions.
!
Page 18
SC510 Chassis Manual
4-2
JIHDB
FEA
LKGC
R E V I S I O N S / -×-q
REV
ª©¥»
DESCRIPTION
±Ô-z
LOCATION
¦ì¸m
DRAWN
-×§ïªÌ
DATE
¤é´Á
4-2 Removing the Chassis Cover
Remove the five screws that hold the chassis cover in place.There are two
screws on each side of the chassis, and one screw on the back.
Once the screws have been removed, lift the cover upward to remove it from
the chassis.
1.
2.
Warning: Except for short periods of time, do NOT operate the server without the cover in place. The chassis cover must be in place to allow proper airflow and prevent overheating.
Figure 4-1: Removing the Chassis Cover
!
1
2
1
1
Page 19
4-3
Chapter 4: Chassis Setup and Maintenance
4-3 Installing the Hard Drives
Figure 4-2A: Installing the 3.5" Hard Drive
R E V I S I O N S / -×-q
REV
ª©¥»
DESCRIPTION
±Ô-
z
LOCATION
¦ì¸m
DRAWN
-×§ïªÌ
DATE
¤é´Á
Figure 4-2B: Installing the 2.5" Hard Drives
The 3.5" hard drive screws directly into the chassis
The 2.5" hard drives (1) must be installed in their brackets (2) before they are screwed into the chassis
JIHDB
FEA
LKGC
R E V I S I O N S / -×-q
REV
ª©¥»
DESCRIPTION
±Ô-z
LOCATION
¦ì¸m
DRAWN
-×§ïªÌ
DATE
¤é´Á
1
2
Page 20
SC510 Chassis Manual
4-4
4-4 Installing the Motherboard
Figure 4-3: Chassis Standoffs
Permanent and Optional Standoffs
Standoffs prevent short circuits by securing space between the motherboard and
the chassis surface. The SC510-200B chassis includes permanent standoffs in
locations used by most motherboards. These standoffs accept the rounded Phillips
head screws included in the SC510-200B accessories packaging.
When using the Micro ATX 9.6"x9.6" motherboard, use the permanent standoffs,
located within the chassis. When using the ATX motherboard, use the optional
standoffs, included in the chassis accessory box. To use an optional standoff, you
must place the hexagonal screw through the bottom of the chassis and secure the
screw with the hexagon nut (rounded side up).
Page 21
4-5
Chapter 4: Chassis Setup and Maintenance
Installing the Motherboard:
Review the documentation that came with your motherboard. Become
familiar with component placement, requirements, precautions, and cable
connections.
Open the chassis cover.
As required by your motherboard, install standoffs in any areas that do not
have a permanent standoff. To do this:
A. Place a hexagonal standoff screw through the bottom the chassis.
B. Secure the screw with the hexagon nut (rounded side up).
Lay the motherboard on the chassis aligning the permanent and optional
standoffs
Secure the motherboard to the chassis using the rounded, Phillips head
screws.
Secure the CPU(s), heatsinks, and other components to the motherboard as
described in the motherboard documentation.
Connect the cables between the motherboard, backplane, chassis, front pan
-
el, and power supply, as needed. Also, the fans may be temporarily removed
to allow access to the backplane ports.
1.
2.
3.
4.
5.
6.
7.
Page 22
SC510 Chassis Manual
4-6
Add-on Card/Expansion Slot Setup
SC510 chassis includes an I/O slot for the optional add-on card. A full-height, half-
length PCI add-on card is supported. A riser card is required in order to adapt the
add-on card to the 1U chassis. For further information on add-on cards and risers
cards, refer to the Supermicro website at www.supermicro.com
JIHDB
FEA
LKGC
MODEL NO./ ¾÷«¬ :
TITLE / «~¦W :
Ablecom Technology Inc.
A
BLEC
¤j˚T¬ì§ÞªÑ¥÷¦³--¤½¥q
M
R E V I S I O N S / -×-q
REV
ª©¥»
DESCRIPTION
±Ô-z
LOCATION
¦ì¸m
DRAWN
-×§ïªÌ
DAT
E
¤é´Á
SC510
RANGE
½d³ò
TOLERANCE
¤½®t
X.xx
±
0.10
Figure 4-4B: Install the Add-on Card and Riser Card
Add-on/Expansion
Card Slot
Riser Card
Add-on Card
Add-on Card Clip
A
B C D E F G H I J K L M
R E V I S I O N S / -×-q
REV
ª©¥»
DESCRIPTION
±Ô-
z
LOCATION
¦ì¸m
DRAWN
-×§ïªÌ
DATE
¤é´Á
Add-on Card Clip
Figure 4-4A: Locate the Add-on Card Clip
Locate the add-on card clip on the back of the chassis
Remove the screws holding the add-on card clip and the dummy bracket
which covers the openings in the back of the chassis.
Remove the add-on card clip and the dummy plate from the chassis.
Outside of the chassis, put the add-on card and the riser card together by
Inserting the add-on card into the riser card.
1.
2.
3.
4.
Page 23
4-7
Chapter 4: Chassis Setup and Maintenance
B C D E F G H I J K L M
R E V I S I O N S / -×-q
REV
ª©¥»
DESCRIPTION
±Ô-
z
LOCATION
¦ì¸m
DRAWN
-×§ïªÌ
DATE
¤é´Á
Figure 4-4C: Replace the Add-on Card Clip
Insert the assembled add-on card and riser card into the expansion slot inside
the chassis, carefully aligning the plate of the add-on card with the openings
in the back of the chassis.
Replace the add-on card clip and screw it onto the chassis to hold the add-on
card in place.
5.
6.
Note that if the length of the add-on card is less than 125mm, the user may choose
to install both the add-on card and a 3.5" hard drive.
Page 24
SC510 Chassis Manual
4-8
4-5 Replacing the Heatsink
The SC510-200B Chassis includes a heatsink, which conducts heat away from the
motherboard.
Unplug all power leading to the chassis.
Remove the motherboard following the directions in section 4-4.
Remove the 4 mounting screws which attach the heatsink to the motherboard
and set them aside for later use.
Carefully lift the heatsink from the motherboard.
Align the holes of the replacement heatsink with the mounting thru holes in
the motherboard
Using the screws which were set aside previously, reattach the heatsink to the
motherboard.
Reattach the motherboard using the directions in section 4-4.
1.
2.
3.
4.
5.
6.
7.
JIHDB
FEA
LKGC
R E V I S I O N S / -×-q
REV
ª©¥»
DESCRIPTION
±Ô-z
LOCATION
¦ì¸m
DRAWN
-×§ïªÌ
DATE
¤é´Á
Figure 4-5: Installing the Heatsink
Page 25
4-9
Chapter 4: Chassis Setup and Maintenance
4-6 Installing the Air Shroud
Air shrouds concentrate airflow to maximize fan efficiency. The SC510-200B chassis
air shroud does not require screws to set up.
Figure 4-6: Air Shroud for SC510-200B Chassis
Place the air shroud in the chassis. The air shroud fits behind the fan closest to
the power supply.
Use the clip on the fan housing to hold the air shroud in place. (See item 1
above)
1
Page 26
SC510 Chassis Manual
4-10
Checking the Server's Air Flow
Make sure there are no objects to obstruct airflow in and out of the server.
Use only recommended server parts.
Make sure no wires or foreign objects obstruct air flow through the chassis.
Pull all excess cabling out of the airflow path, or use shorter cables.
The control panel LEDs inform you of system status. See “Chapter 3: System
Interface” for details on the LEDs and the control panel buttons.
1.
2.
3.
4.
In most cases, the chassis power supply and fan are pre-installed. If you need to
install fans, continue to the Systems Fan section of this chapter. If the chassis will be
installed into a rack, continue to the next chapter for rack installation instructions.
Page 27
4-11
Chapter 4: Chassis Setup and Maintenance
JIHDB
FEA
REV
ª©¥»
Two heavy duty fans within a single fan housing provide cooling for the chassis.
These fans circulate air through the chassis as a means of lowering the chassis
internal temperature.
4-7 Replacing System Fans
Figure 4-7: System Fans
Mounting
thru holes
If necessary, open the chassis while the power is running to determine which
fan has failed. (Never run the server for an extended period of time with the
chassis open.)
Turn off the power to the system and unplug the system from the outlet.
Remove the failed fan's power cord from the serverboard.
Remove the fan housing from the chassis by removing the two screws which
attach the housing to the chassis. These screws are located in the mount
-
ing thru holes on either side of the fan housing. (See figure 4-6). Set these
screws aside for later use.
Disconnect the fan wiring from the connectors and carefully lift the fan hous
-
ing out of the chassis.
1.
2.
3.
4.
5.
Fan housing
Fans
Page 28
SC510 Chassis Manual
4-12
Figure 4-8: Removing Fan Housing from Chassis
To remove the fans from the fan housing, gently push upwards on the fan
from the underside of the fan housing. Gently ease the fan out of the top of
the fan housing
6.
JIHDB
FEA
REV
ª©¥»
Slide the replacement fan upwards through the bottom of the fan housing.
Reconnect the fan wiring and replace the fan housing in the chassis using the
mounting screws previously set aside.
7.
8.
Figure 4-9: Removing Fans from Fan Housing
Page 29
4-13
Chapter 4: Chassis Setup and Maintenance
The SC510-200B Chassis has a 200 watt power supply. This power supply is auto-
switching capable. This enables it to automatically sense and operate at a 100v to
240v input voltage.
The SC510-200B chassis has one power supply. In the unlikely event that the
power supply unit fails, the system will shut down and you will need to change the
power supply unit.
New units can be ordered directly from Supermicro (see contact information in the
Preface).
Replacing the Power Supply
Unplug all power leading to the chassis.
Disconnect all wiring from the power supply.
Remove the four screws which hold the power supply in the chassis. The
two front mounting screws are located on the front of the power supply. The
two rear mounting screws are accessed on the underside of the chassis and
1.
2.
3.
4-8 Power Supply
Figure 4-10: Installing the Power Supply
Power Supply
Mounting Thru Holes
Front Mounting Screws
Rear Mounting Screws
Page 30
SC510 Chassis Manual
4-14
extend upwards through the mounting thru holes, to hold the power supply in
place. Set the screws aside for later use.
Remove the power supply from the chassis.
Align the mounting thru holes on the power supply with the mounting holes
in the chassis and reattach the power supply to the chassis using the four
screws which were previously set aside
Connect the chassis wiring to the power supply.
4.
5.
6.
Page 31
5-1
Chapter 5: Rack Installation
Chapter 5
Rack Installation
5-1 Overview
This chapter provides a quick setup checklist to get your chassis up and running.
Following these steps in the order given should enable you to have the system
operational in a minimal amount of time.
5-2 Unpacking the System
You should inspect the box the chassis was shipped in, and note if it was damaged
in any way. If the chassis itself shows damage, you should file a damage claim with
the carrier who delivered it.
Decide on a suitable location for the rack unit that will hold your chassis. It should
be situated in a clean, dust-free area that is well ventilated. Avoid areas where
heat, electrical noise and electromagnetic fields are generated. You will also need
it placed near a grounded power outlet. Be sure to read the Rack and Server Pre-
cautions in the next section.
5-3 Preparing for Setup
The box your chassis was shipped in should include four mounting screws, which
you will need if you intend to install the system into a rack. Please read this section
in its entirety before you begin the installation procedure outlined in the sections
that follow.
Choosing a Setup Location
Leave enough clearance in front of the rack to enable you to open the front
door completely (~25 inches).
Leave approximately 30 inches of clearance in the back of the rack to allow for
sufficient airflow and ease in servicing.
Page 32
SC510 Chassis Manual
5-2
This product is for installation only in a Restricted Access Location (dedicated
equipment rooms, service closets and similar environments).
Rack Precautions
Ensure that the leveling jacks on the bottom of the rack are fully extended to
the floor with the full weight of the rack resting on them.
In single rack installation, stabilizers should be attached to the rack.
In multiple rack installations, the racks should be coupled together.
Always make sure the rack is stable before extending a component from the
rack.
You should extend only one component at a time. Extending two or more simul
-
taneously may cause the rack to become unstable.
General Server Precautions
Review the electrical and general safety precautions that came with the com-
ponents you are adding to your chassis.
Determine the placement of each component in the rack.
Install the heaviest server components on the bottom of the rack first, and then
work up.
Use a regulating, uninterruptible power supply (UPS) to protect the server from
power surges, voltage spikes and to keep your system operating in case of a
power failure.
Allow the hard drives and power supply modules to cool before touching
them.
Always keep the rack's front door, all panels and all components on the servers
closed when not servicing, in order to maintain proper cooling.
Warnings and Precautions!
!
!
Page 33
5-3
Chapter 5: Rack Installation
Rack Mounting Considerations
Ambient Operating Temperature
If installed in a closed or multi-unit rack assembly, the ambient operating tempera-
ture of the rack environment may be greater than the ambient temperature of the
room. Therefore, consideration should be given to installing the equipment in an
environment compatible with the manufacturer’s maximum rated ambient tempera-
ture (TMRA).
Reduced Airflow
Equipment should be mounted into a rack so that the amount of airflow required
for safe operation is not compromised.
Mechanical Loading
Equipment should be mounted into a rack so that a hazardous condition does not
arise due to uneven mechanical loading.
Circuit Overloading
Consideration should be given to the connection of the equipment to the power
supply circuitry and the effect that any possible overloading of circuits might have
on overcurrent protection and power supply wiring. Appropriate consideration of
equipment nameplate ratings should be used when addressing this concern.
Reliable Ground
A reliable ground must be maintained at all times. To ensure this, the rack itself
should be grounded. Particular attention should be given to power supply connec-
tions other than the direct connections to the branch circuit (for example, the use
of power strips, and other devices).
Page 34
SC510 Chassis Manual
5-4
5-4 Rack Mounting Instructions
This section provides information on installing the SC510 chassis into a rack unit
There are a variety of rack units on the market, which may mean the assembly
procedure will differ slightly. You should also refer to the installation instructions that
came with the rack unit you are using.
Installing the Chassis into a Rack:
Confirm that chassis includes the four mounting screws required to mount the
chassis into a rack
Align the thru holes of the chassis with the thru holes of the rack.
Insert the mounting screws into the thru holes in the front of the chassis and
through the thru holes in the rack
1.
2.
3.
Figure 5-1: Installing the Chassis into a Rack
Page 35
A-1
Appendix A: Chassis Cables
Appendix A
Cables, Screws,
and other Accessories
A-1 Overview
This appendix lists supported cables for your chassis system. It only includes the
most commonly used components and configurations. For more compatible cables,
refer to the manufacturer of the motherboard you are using and our Web site at:
www.supermicro.com.
A-2 Cables Included with SC510-200B Chassis
SC510-200B
Part # Type Length Description
CBL-0236L Ribbon 13"
16 pin to 16 pin ribbon cable for control panel
- Cable 6' Regional power cord
A-3 Optional Accessories
The following accessories are compatible with the SC510-200B Chassis.
Hard Drive Carrier (Tray):
MCP-220-00044-0N 2.5" hard drive carrier. One carrier can hold up to two 2.5"
hard drives. The SC510-200B can hold up to two 2.5" hard drive carriers, for a
total of four hard drives.
JIHDB
FEA
LKGC
R E V I S I O N S / -×-q
REV
ª©¥»
DESCRIPTION
±Ô-z
LOCATION
¦ì¸m
DRAWN
-×§ïªÌ
DATE
¤é´Á
Figure A-1: Hard Driver Carrier (Tray)
Page 36
SC510 Chassis Manual
A-2
Extending Power Cables
Although Super Micro chassis are designed with to be efficient and cost-effective,
some compatible motherboards have power connectors located in different areas.
To use these motherboards you may have to extend the power cables to the mother
boards. To do this, use the following chart as a guide.
Power Cable Extenders
Number of Pins Cable Part # Length
24 pin CBL - 0042 7.9”(20 CM)
20 pin CBL - 0059 7.9”(20 CM)
8 pin CBL - 0062 7.9”(20 CM)
4 pin CBL - 0060 7.9”(20 CM)
Front Panel to the Motherboard
The SC510 chassis includes a cable to connect the chassis front panel to the
motherboard. If your motherboard uses a different connector, use the following list
to find a compatible cable.
Front Panel to Motherboard Cable (Ribbon Cable)
Number of Pins
(Front Panel)
Number of Pins
(Motherboard
Cable Part #
16 pin 16 pin CBL - 0049
16 pin 20 pin CBL - 0048
20 pin 20 pin CBL - 0047
16 pin various* CBL - 0068
20 pin various* CBL - 0067
* Split Cables: Use these cable if your motherboard requires several different con-
nections from the front panel.
Page 37
A-3
Appendix A: Chassis Cables
A-4 Chassis Screws
The accessory box includes all the screws needed to setup your chassis. This
section lists and describes the most common screws used. Your chassis may not
require all the parts listed.
Flat head
M4 x 4 mm
[0.157]
RAIL
Round head
M4 x 4 mm
[0.157]
Flat head
M5 x 12 mm[0.472]
Washer for M5
DVD-ROM, CD-ROM, and FLOPPY DRIVE
Flat head
6-32 x 5 mm
[0.197]
Pan head
6-32 x 5 mm
[0.197]
Round head
M3 x 5 mm
[0.197]
Pan head
6-32 x 5 mm
[0.197]
M/B
Flat head
6-32 x 5 mm
[0.197]
HARD DRIVE
Thumb screw
6-32 x 5 mm
[0.197]
M/B standoff
6-32 to 6-32
M/B STANDOFFS
M/B (CPU)
standoff
M5 to 6-32
Round head M2.6 x 5 mm
[0.197]
1/U M/B standoff
6-32 x 5 mm
[0.197]
Page 38
B-1
Appendix B: Power Supply Specifications
Appendix B
SC510 Power Supply Specifications
200W
MFR Part # PWS-201-1H
Rated AC Voltage
100 - 240V 50 - 60Hz 4-2Amp
+5V standby 2 Amp
+12V 16 Amp
+5V 8 Amp
+3.3V 8 Amp
-12V 0.5 Amp
Page 39