Supero SC219 Chassis Series, SC219A-R920WB, SC219A-R920UB, SC219A-R920LPB User Manual

Page 1
SC219 Chassis Series
SC219A-R920UB SC219A-R920LPB
SC219A-R920WB
USER’S MANUAL
1.0
SUPER
SUPERMICR
®
Page 2
SC219 Chassis Manual
ii
Manual Revision 1.0 Release Date: June 6, 2012
The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccuracies that may be contained in this document, makes no commitment to update or to keep current the information in this manual, or to notify any person or organization of the updates. Please Note: For the most up-to-date version of this
manual, please see our web site at www.supermicro.com.
Super Micro Computer, Inc. ("Supermicro") reserves the right to make changes to the product described in this manual at any time and without notice. This product, including software and documentation, is the property of Supermicro and/or its licensors, and is supplied only under a license. Any use or reproduction of this product is not allowed, except as expressly permitted by the terms of said license.
IN NO EVENT WILL SUPERMICRO BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL, SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO USE THIS PRODUCT OR DOCUMENTATION, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. IN PARTICULAR, SUPERMICRO SHALL NOT HAVE LIABILITY FOR ANY HARDWARE, SOFTWARE, OR DATA STORED OR USED WITH THE PRODUCT, INCLUDING THE COSTS OF REPAIRING, REPLACING, INTEGRATING, INSTALLING OR RECOVERING SUCH HARDWARE, SOFTWARE, OR DATA.
Any disputes arising between manufacturer and customer shall be governed by the laws of Santa Clara County in the State of California, USA. The State of California, County of Santa Clara shall be the exclusive venue for the resolution of any such disputes. Super Micro's total liability for all claims will not exceed the price paid for the hardware product.
California Best Management Practices Regulations for Perchlorate Materials: This Perchlorate warning applies only to products containing CR (Manganese Dioxide) Lithium coin cells. “Perchlorate Material-special handling may apply. See www.dtsc.ca.gov/hazardouswaste/perchlorate”
WARNING: Handling of lead solder materials used in this product may expose you to lead, a chemical known to the State of California to cause birth defects and other reproductive harm.
Unless you request and receive written permission from Super Micro Computer, Inc., you may not copy any part of this document.
Information in this document is subject to change without notice. Other products and companies referred to herein are trademarks or registered trademarks of their respective companies or mark holders.
Copyright © 2012 by Super Micro Computer, Inc. All rights reserved.
Printed in the United States of America
Page 3
iii
Preface
Preface
This manual is written for professional system integrators and PC technicians. It
provides information for the installation and use of the SC219 chassis. Installation
and maintenance should be performed by experienced technicians only.
Supermicro’s SC219 chassis features a unique and highly optimized 2U server
design which provides optimal use of space, without compromising cooling. The
SC219 chassis is equipped with sixteen drive bays which support hot-swappable
SAS/SATA hard drives, one 5.25" drive bay and two slim peripheral drive bays. The
SC219 comes equipped with redundant 920 Watt power supplies for superb power
savings. The chassis provides maximum features in a 2U form factor.
This document lists compatible parts and congurations available when this docu-
ment was published. Always refer to our Web site for updates on supported parts
and congurations at http://www.supermicro.com
Page 4
SC219 Chassis Manual
iv
Manual Organization
Chapter 1 Introduction
The introduction provides a list of the main components included with this chassis
and describes the primary features of the SC219 chassis. This chapter also includes
contact information.
Chapter 2 System Safety
Chapter 2 lists warnings, precautions, and system safety. You should thoroughly
familiarize yourself with this chapter for a general overview of safety precautions
that should be followed before installing and servicing the SC219 chassis.
Chapter 3 System Interface
This chapter provides details on the system interface, which includes the functions
and information provided by the control panel LEDs on the chassis, and by other
LEDs located throughout the system.
Chapter 4 Chassis Setup and Maintenance
Refer to this chapter for detailed information on the chassis. Follow the procedures
given in this chapter when installing, removing, or reconguring your chassis.
Chapter 5 Rack Installation
Refer to this chapter for detailed information on chassis rack installation. You should
follow the procedures given in this chapter when installing, removing or reconguring
your chassis into a rack environment.
Appendix A
This section references cables, which are compatible with your SC219 system. Refer
to our Web site for additional information on cabling at www.supermicro.com.
Appendix B
This chapter lists supported power supply information for your SC219 system. Refer
to our Web site for additional details at www.supermicro.com.
Page 5
v
Preface
Appendix C
This section provides detailed information on the SAS-213A backplane. Additional
information can by found on our Web site, at www.supermicro.com
Page 6
SC219 Chassis Manual
vi
Table of Contents
Manual Organization ..........................................................................................iv
Chapter 1 Introduction
1-1 Overview ......................................................................................................... 1-1
1-2 Shipping List .................................................................................................... 1-1
1-3 Contacting Supermicro .................................................................................... 1-2
1-4 Returning Merchandise for Service................................................................. 1-3
Chapter 2 System Safety
2-1 Overview ......................................................................................................... 2-1
2-2 Warnings and Precautions .............................................................................. 2-1
2-3 Preparing for Setup ......................................................................................... 2-1
2-4 Electrical Safety Precautions .......................................................................... 2-2
2-5 General Safety Precautions ............................................................................ 2-3
2-6 System Safety ................................................................................................. 2-3
Chapter 3 System Interface
3-1 Overview ......................................................................................................... 3-1
3-2 Control Panel Buttons ..................................................................................... 3-2
3-3 Control Panel LEDs ........................................................................................ 3-2
3-4 Drive Carrier LEDs .......................................................................................... 3-4
Chapter 4 Chassis Setup and Maintenance
4-1 Overview ......................................................................................................... 4-1
4-2 Installation and General Maintenance ............................................................ 4-1
Installation Topics ............................................................................................ 4-1
4-3 Removing the Chassis Cover ......................................................................... 4-2
4-4 Installing Hard Drives ...................................................................................... 4-3
4-5 Installing the I/O Shield (LP Version Only) ..................................................... 4-5
I/O Shield (LP Version Only) ........................................................................... 4-5
4-6 Installing Chassis Standoffs ............................................................................ 4-6
Permanent and Optional Standoffs ................................................................. 4-6
4-7 Installing the Motherboard .............................................................................. 4-7
4-8 Installing the Riser and Expansion Cards ....................................................... 4-9
4-9 Installing the Air Shroud .................................................................................4-11
Installing the Air Shroud in the Chassis .........................................................4-11
4-10 Checking the Airow ..................................................................................... 4-12
Installation Complete ..................................................................................... 4-12
4-11 System Fans ................................................................................................. 4-13
4-12 Power Supply ............................................................................................... 4-15
Page 7
vii
Preface
4-13 Power Distributor ...........................................................................................4-16
4-14 Removing the Backplane .............................................................................. 4-17
4-15 Installing the Backplane ................................................................................ 4-19
Chapter 5 Rack Installation
5-1 Overview ......................................................................................................... 5-1
5-2 Unpacking the System .................................................................................... 5-1
5-3 Preparing for Setup ......................................................................................... 5-1
Choosing a Setup Location ............................................................................. 5-1
5-4 Warnings and Precautions .............................................................................. 5-2
Rack Precautions ............................................................................................ 5-2
General Server Precautions ............................................................................ 5-2
5-5 Rack Mounting Considerations ....................................................................... 5-3
Ambient Operating Temperature ..................................................................... 5-3
Reduced Airow .............................................................................................. 5-3
Mechanical Loading ........................................................................................ 5-3
Circuit Overloading .......................................................................................... 5-3
Reliable Ground .............................................................................................. 5-3
5-6 Rack Mounting Instructions ............................................................................. 5-4
Identifying the Sections of the Rack Rails ...................................................... 5-4
Locking Tabs ................................................................................................... 5-5
Releasing the Inner Rail ................................................................................. 5-5
Installing The Inner Rails on the Chassis ....................................................... 5-6
Installing the Outer Rails on the Rack ............................................................ 5-7
Standard Chassis Installation ......................................................................... 5-8
Optional Quick Installation Method ................................................................. 5-9
Appendix A SC219 Chassis Cables
Appendix B SC219 Power Supply Specications
Appendix C SAS-213A Backplane Specications
Page 8
SC219 Chassis Manual
viii
Notes
Page 9
Chapter 1
Introduction
1-1 Overview
Supermicro’s SC219 chassis provides sixteen hot-swappable 2.5” SAS/SATA hard
drive bays, one 5.25” hard drive and two peripheral drive bays in an efcient 2U
form factor, designed for the most frequently encountered applications. The chassis
is also equipped with a redundant 920W Platinum Level (94%+) power supply for
superb power savings and optimized cooling.
1-2 Shipping List
Please visit the following link for the latest shipping lists and part numbers for your par-
ticular chassis model. http://www.supermicro.com/products/chassis/2U/?chs=219
Chapter 1 Introduction
1-1
SC219
Model CPU HDD I/O Slots
Power
Supply
SC219A-R920UB
DP/UP 16x SAS/SATA
4x FH, 2x
LP
920W
(94%+ Platinum)
Redundant
SC219A-R920LPB
DP/UP 16x SAS/SATA 7x LP
920W
(94%+ Platinum)
Redundant
SC219A-R920WB
DP/UP 16x SAS/SATA
4x FH, 3x
LP
920W
(94%+ Platinum)
Redundant
Legend:
UP = Single processor support
DP = Dual processor support
FH = Full-height, half-length
LP = Low-prole
Page 10
SC219 Chassis Manual
1-2
Contacting Supermicro
Headquarters
Address: Super Micro Computer, Inc.
980 Rock Ave.
San Jose, CA 95131 U.S.A.
Tel: +1 (408) 503-8000
Fax: +1 (408) 503-8008
Email: marketing@supermicro.com (General Information)
support@supermicro.com (Technical Support)
Web Site: www.supermicro.com
Europe
Address: Super Micro Computer B.V.
Het Sterrenbeeld 28, 5215 ML
's-Hertogenbosch, The Netherlands
Tel: +31 (0) 73-6400390
Fax: +31 (0) 73-6416525
Email: sales@supermicro.nl (General Information)
support@supermicro.nl (Technical Support)
rma@supermicro.nl (Customer Support)
Asia-Pacic
Address: Super Micro Computer, Inc.
4F, No. 232-1, Liancheng Rd.
Chung-Ho Dist., New Taipei City 235
Taiwan
Tel: +886-(2) 8226-5990
Fax: +886-(2) 8226-3991
Web Site: www.supermicro.com.tw
Technical Support:
Email: support@supermicro.com.tw
Tel: +886-(2)-8226-5990
Page 11
1-3
Chapter 1: Introduction
1-4 Returning Merchandise for Service
A receipt or copy of your invoice marked with the date of purchase is required be-
fore any warranty service will be rendered. You can obtain service by calling your
vendor for a Returned Merchandise Authorization (RMA) number. When returning
to the manufacturer, the RMA number should be prominently displayed on the
outside of the shipping carton, and mailed prepaid or hand-carried. Shipping and
handling charges will be applied for all orders that must be mailed when service
is complete.
For faster service, RMA authorizations may be requested online (http://www.
supermicro.com/support/rma/).
Whenever possible, repack the chassis in the original Supermicro carton, using the
original packaging material. If these are no longer available, be sure to pack the
chassis securely, using packaging material to surround the chassis so that it does
not shift within the carton and become damaged during shipping.
This warranty only covers normal consumer use and does not cover damages in-
curred in shipping or from failure due to the alteration, misuse, abuse or improper
maintenance of products.
During the warranty period, contact your distributor rst for any product problems.
Page 12
SC219 Chassis Manual
1-4
Notes
Page 13
2-1
Chapter 2: System Safety
Chapter 2
System Safety
2-1 Overview
This chapter lists warnings, precautions, and system safety. You should thoroughly
familiarize yourself with this chapter for a general overview of safety precautions
that should be followed before installing and servicing this chassis.
2-2 Warnings and Precautions
You should inspect the box the chassis was shipped in and note if it was damaged
in any way. If the chassis itself shows damage, le a damage claim with carrier
who delivered your system.
Decide on a suitable location for the rack unit that will hold the chassis. It should be
situated in a clean, dust-free area that is well ventilated. Avoid areas where heat,
electrical noise and electromagnetic elds are generated.
You will also need it placed near at least one grounded power outlet. When con-
gured, the SC219 chassis includes a power supply which requires a grounded
outlet.
2-3 Preparing for Setup
The SC219 chassis includes a set of rail assemblies, including mounting brackets
and mounting screws you will need to install the system into a rack. Please read
this manual in its entirety before beginning the rack installation procedure.
Page 14
SC219 Chassis Manual
2-2
2-4 Electrical Safety Precautions
Basic electrical safety precautions should be followed to protect yourself from harm
and the SC219 from damage:
•Be aware of the locations of the power on/off switch on the chassis as well
as the room’s emergency power-off switch, disconnection switch or electrical
outlet. If an electrical accident occurs, you can then quickly remove power from
the system.
•Do not work alone when working with high-voltage components.
•Power should always be disconnected from the system when removing or install-
ing main system components, such as the serverboard, memory modules and
the DVD-ROM and peripheral drives (not necessary for hot-swappable drives).
When disconnecting power, you should rst power down the system with the
operating system and then unplug the power cords from all the power supply
modules in the system.
•When working around exposed electrical circuits, another person who is fa-
miliar with the power-off controls should be nearby to switch off the power, if
necessary.
•Use only one hand when working with powered-on electrical equipment. This
is to avoid making a complete circuit, which will cause electrical shock. Use
extreme caution when using metal tools, which can easily damage any electrical
components or circuit boards they come into contact with.
•Do not use mats designed to decrease electrostatic discharge as protection from
electrical shock. Instead, use rubber mats that have been specically designed
as electrical insulators.
•The power supply power cord must include a grounding plug and must be
plugged into grounded electrical outlets.
•Serverboard battery: CAUTION - There is a danger of explosion if the onboard
battery is installed upside down, which will reverse its polarities This battery
must be replaced only with the same or an equivalent type recommended by
the manufacturer. Dispose of used batteries according to the manufacturer’s
instructions.
Page 15
2-3
Chapter 2: System Safety
•Please handle used batteries carefully. Do not damage the battery in any way;
a damaged battery may release hazardous materials into the environment. Do
not discard a used battery in the garbage or a public landll. Please comply
with the regulations set up by your local hazardous waste management agency
to dispose of your used battery properly.
•DVD-ROM laser: CAUTION - This server may have come equipped with a
DVD-ROM drive. To prevent direct exposure to the laser beam and hazardous
radiation exposure, do not open the enclosure or use the unit in any uncon-
ventional way.
2-5 General Safety Precautions
•Keep the area around the chassis clean and free of clutter.
•Place the chassis top cover and any system components that have been re-
moved away from the system or on a table so that they won’t accidentally be
stepped on.
•While working on the system, do not wear loose clothing such as neckties and
unbuttoned shirt sleeves, which can come into contact with electrical circuits or
be pulled into a cooling fan.
•Remove any jewelry or metal objects from your body, which are excellent metal
conductors that can create short circuits and harm you if they come into contact
with printed circuit boards or areas where power is present.
•After accessing the inside of the system, close the system back up and secure
it to the rack unit with the retention screws after ensuring that all connections
have been made.
2-6 System Safety
Electrostatic discharge (ESD) is generated by two objects with different electrical
charges coming into contact with each other. An electrical discharge is created to
neutralize this difference, which can damage electronic components and printed
circuit boards. The following measures are generally sufcient to neutralize this
difference before contact is made to protect your equipment from ESD:
•Do not use mats designed to decrease electrostatic discharge as protection from
electrical shock. Instead, use rubber mats that have been specically designed
as electrical insulators.
Page 16
SC219 Chassis Manual
2-4
•Use a grounded wrist strap designed to prevent static discharge.
•Keep all components and printed circuit boards (PCBs) in their antistatic bags
until ready for use.
•Touch a grounded metal object before removing any board from its antistatic
bag.
•Do not let components or PCBs come into contact with your clothing, which may
retain a charge even if you are wearing a wrist strap.
•Handle a board by its edges only; do not touch its components, peripheral chips,
memory modules or contacts.
•When handling chips or modules, avoid touching their pins.
•Put the serverboard and peripherals back into their antistatic bags when not
in use.
•For grounding purposes, make sure your computer chassis provides excellent
conductivity between the power supply, the case, the mounting fasteners and
the serverboard.
Page 17
3-1
Chapter 3: System Interface
Chapter 3
System Interface
3-1 Overview
There are LEDs on the left control panel and LEDs on the drive carriers to keep
you constantly informed of the over-all status of the system, as well as the activity
and health of specic components. SC219 models include a power on/off button
and a reset button. This chapter explains the meanings of all LED indicators and
the appropriate responses you may need to take.
Figure 3-1: Chassis User Interface
SUPERMICR
®
Page 18
SC219 Chassis Manual
3-2
Power: Indicates power is being supplied to the system's power supply units. This
LED should normally be illuminated when the system is operating.
HDD: Indicates IDE channel activity. SAS/SATA drive and/or DVD-ROM drive activ-
ity when ashing.
3-3 Control Panel LEDs
The control panel is located on the front of the SC219 chassis and has ve LEDs.
These LEDs provide you with critical information related to different parts of the
system. This section explains what each LED indicates when illuminated and any
corrective action you may need to take.
Power: The main power switch is used to apply or remove power from the power
supply to the server system. Turning off system power with this button removes the
main power, but keeps standby power supplied to the system. Therefore, you must
unplug system before servicing.
Reset: The reset button is used to reboot the system. A needle, pen, or other small
device is required to activate this button and reset the system
3-2 Control Panel Buttons
There are two push-buttons located on the control panel on the left side of the
chassis. These are a power on/off button and a reset button.
Page 19
3-3
Chapter 3: System Interface
Power Failure: When this LED ashes, it indicates a power failure in the power
supply.
NIC1: Indicates network activity on GLAN1 when ashing.
NIC2: Indicates network activity on GLAN2 when ashing.
!
Informational LED
Status Description
Continuously on and red
An overheat condition has occured. (This may be caused by cable congestion.)
Blinking red (1Hz) Fan failure, check for an inoperative fan.
Blinking red (0.25Hz) Power failure, check for a non-operational power supply.
Solid blue
Local UID has been activated. Use this function to locate the server in a rack mount environment.
Blinking blue (300 mSEC)
Remote UID is on. Initiate this function from a remote location to identify the server.
Page 20
SC219 Chassis Manual
3-4
3-4 Drive Carrier LEDs
Your chassis uses SAS/SATA drives.
SAS/SATA Drives
Each SAS/SATA drive carrier has two LEDs.
Green LED:
Each SAS/SATA drive carrier has a green LED. When illuminated, this green LED
(on the front of the SATA drive carrier) indicates drive activity. A connection to the
SATA backplane enables this LED to blink on and off when that particular drive
is being accessed.
Green LED
Status Description
Continuously on SAS/SATA drive is being used continuously
Continuously off SAS/SATA drive is being used continuously
Flashing on and off SAS/SATA drive is being accessed
Red LED
Status Description
Continuously on SAS/SATA drive is being used continuously
Flashing on and off
SAS/SATA drive is being rebuilt with RAID functionality
after a drive has been replaced.
Page 21
4-1
Chapter 4: Chassis Setup and Maintenance
Chapter 4
Chassis Setup and Maintenance
4-1 Overview
This chapter covers the steps required to install components and perform mainte-
nance on the SC219 chassis. The only tool you will need to install components and
to perform maintenance is a Phillips screwdriver.
4-2 Installation and General Maintenance
The following sections will provide you with information on installing components
and performing general mainenance on the system.
Installation Topics
Removing the Chassis Cover
Installing Hard Drives
Installing the I/O Shield (LP chassis only)
Installing Chassis Standoffs
Installing the Motherboard
Installing the Riser and Expansion Cards
Installing the Air Shroud
General Maintenance Topics
System Fans
Power Supply
Power Distributor
Removing and Installing the Backplane
Review the warnings and precautions listed in the manual before setting up or servicing this chassis. These include in­formation in Chapter 2 System Safety and the warning/precau­tions listed in the setup instructions.
Page 22
SC219 Chassis Manual
4-2
4-3 Removing the Chassis Cover
Removing the Chassis Cover the Chassis Cover
1. Disconnect the chassis from any power source.
2. Press both release tabs at the same time to release the cover from the locked
position.
3. Once the top cover has been released, slide the cover backwards, toward the
rear of the chassis.
4. Lift the cover up and off the chassis.
Warning: Except for short periods of time, do NOT operate the server without the cover in place. The chassis cover must be in
placetoallowproperairowandpreventoverheating.
Figure 4-1: Removing the Chassis Cover
1
2
1
3
Page 23
4-3
Chapter 4: Chassis Setup and Maintenance
Warning: Only enterprise level hard drives are recommended for use in this chassis.
4-4 Installing Hard Drives
The SC219 comes equipped with sixteen hot-swappable hard drives. Only SAS
or enterprise SATA HDDs are recommended for use in the SC219 chassis.
Hot-swappable drives may be installed and removed from the chassis without
powering down the server.
Removing Hard Drive Carriers from the Chassis
1. Press the release button on the drive carrier. This extends the drive carrier
handle.
2. Use the handle to pull the carrier out of the chassis.
Figure 4-2: Removing the Hard Drive Carrier
2
1
Page 24
SC219 Chassis Manual
4-4
Figure 4-3: Installing a Hard Drive in the Drive Carrier
Figure 4-4: Proper Installation of the Hard Drive into the Hard Drive Bay
Installing a Hard Drive into a Drive Carrier
1. Remove the screws securing the dummy drive to the drive carrier.
2. Insert a drive into the carrier with the PCB side facing down and the connec-
tor end toward the rear of the carrier and align the drive in the carrier so that
the mounting holes of the carrier are aligned with the mounting holes of the
drive. Note that there are holes in the carrier marked "SAS" or “SATA” to aid
in correct installation.
3. Secure the drive to the carrier with four screws. Use the four M3 at-head
screws included in the HDD bag of your accessory box. Note that the screws
used to secure the dummy drive to the tray cannot be used to secure the
hard drive.
4. Insert the hard drive and drive carrier into its bay vertically, keeping the carrier
oriented so that the release button is on the bottom. When the carrier reaches
the rear of the bay, the handle will retract.
5. Using the thumb, push against the upper part of the drive carrier handle.
Push the carrier into the drive bay as illustrated below, until the carrier clicks
into the locked position.
Page 25
4-5
Chapter 4: Chassis Setup and Maintenance
I/O Shield (LP Version Only)
Skip this section when using a UIO/WIO chassis with a UIO/WIO motherboard.
The I/O shield holds the motherboard ports in place. Install the I/O shield before
installing the motherboard. If the motherboard you purchased did not include an I/O
shield, contact the motherboard vendor for a compatible shield.
Installing the I/O Shield in the LP Model Chassis
1. Review the documentation that came with your motherboard. Become familiar
with component placement, requirements, and precautions.
2. Open the chassis cover.
3. With the illustrations facing the outside of the chassis, place the shield into
the space provided at the rear of the chassis as illustrated above.
I/O Shield
Figure 4-5: I/O Shield Placement
4-5 Installing the I/O Shield (LP Version Only)
Page 26
SC219 Chassis Manual
4-6
Figure 4-6: Chassis Standoffs
Permanent and Optional Standoffs
Standoffs prevent short circuits by creating space between the motherboard and the
chassis surface. The SC219 chassis includes permanent standoffs in locations used
by most motherboards. These standoffs accept the rounded Phillips head screws
which are included in the SC219 accessories packaging.
Some motherboards require additional screws for heatsinks, general components
and/or non-standard security. Optional standoffs are included for these mother-
boards. To use an optional standoff, place the hexagonal nut with the rounded side
up, in the holes provided on the oor of the chassis.
Chassis
Standoffs
4-6 Installing Chassis Standoffs
Page 27
4-7
Chapter 4: Chassis Setup and Maintenance
4-7 Installing the Motherboard
Installing the Motherboard
1. Review the documentation that came with your motherboard. Become familiar
with component placement, requirements, cautions, and cable connections.
Note that your motherboard may be different than those illustrated.
2. Remove the chassis from any power source.
3. If necessary, remove the air shroud and riser card bracket.
4. Ensure that the I/O shield has been installed correctly (LP model chassis
only)
5. Compare the mounting holes in the motherboard to those in the chassis. Add
or remove standoffs as needed.
6. Lay the motherboard in the chassis and secure it to the chassis using the
rounded, Phillips head screws which are included in the motherboard bag of
the accessory box. Do not exceed eight pounds of torque when tightening
down the motherboard.
Figure4-7:InstallingtheLowProleMotherboard
Page 28
SC219 Chassis Manual
4-8
Figure 4-8: Motherboard Installed in a UIO/WIO Model Chassis
7. Secure the CPU(s), heatsinks, and other components to the motherboard as
described in the motherboard documentation.
8. Connect the cables between the motherboard, backplane, chassis, front
panel, and power supply, as needed. Additionally, the fans may be temporar-
Page 29
4-9
Chapter 4: Chassis Setup and Maintenance
4-8 Installing the Riser and Expansion Cards
The SC219 chassis supports four full-length half-height expansion cards and two
low-prole expansion cards.
Installing Riser Cards and Full-Length Expansion Cards
1. Remove the chassis from any power source and ensure that the motherboard
has been properly installed.
Figure 4-9: Removing the PCI/PCIE Slot Cover
2. Locate the horizontal full-length and low-prole PCI/PCIE card slots in the
rear of the SC219 chassis. Note that the bottom slot may be reversed on
some chassis models. These chassis require that the bottom card be
installed component side up and the upper three cards must be installed
component side down.
3. Open the clip securing the PCI/PCIE slot cover to the chassis and slide the
slot cover sideways and out of the chassis.
Figure 4-10: Installing the Riser Card and Expansion Cards
Secure the tail
of the riser card
bracket
Full-
Length
Add-On
Card
Riser
Card
Secure the add-on card with the long
card clips
Secure the head of the riser card
bracket
Full-length half­height PCI/PCIE
slot cover
Low-prolePCI/
PCIE slot cover
Page 30
SC219 Chassis Manual
4-10
4. Insert the full-length expansion card into the riser card.
5. Slide the riser card carefully into the PCI/PCIE slot and simultaneously plug it
into the slot on the motherboard.
6. Use two screws to secure the head of the riser card bracket onto the chassis
wall and one screw to secure the riser card bracket to the oor fo the chassis.
7. Use the long card clips to secure the end of each expansion card to the wall
of the chassis.
Installing Low-Prole Expansion Cards
1. Ensure that the riser card and riser card bracket have been correctly installed
in the chassis.
2. Remove the slot cover from the rear low-prole PCI/PCIE slot in the rear of
the chassis.
3. Slide the low-prole expansion card horizontally into the slot on the riser card.
4. Secure the expansion-card into the rear slot of the chassis with the PCI/PCIE
card slot clip.
Page 31
4-11
Chapter 4: Chassis Setup and Maintenance
4-9 Installing the Air Shroud
Air shrouds concentrate airow to maximize fan efciency. The SC219 chassis air
shroud does not require screws for installation.
Installing the Air Shroud in the Chassis
Installing the Air Shroud
1. Lay the chassis on a at, stable surface and remove the chassis cover.
2. Ensure that the motherboard, CPU, heatsink and memory are all properly
installed.
3. If necessary, move any cables that interfere with the air shroud placement.
4. Place the air shroud in the chassis. The air shroud ts just behind the fans in
the fan rack. Slide the air shroud into the grooves just behind the fan rack.
Note that some motherboards may require the air shroud to be modied to
t over the motherboard. The SC219 chassis air shroud is designed with
break-away pieces that may be removed to accomodate differing styles of
motherboards.
Figure 4-11: Air Shroud Installation
4
Page 32
SC219 Chassis Manual
4-12
4-10 CheckingtheAirow
Checking the Server's Airow
1. Make sure there are no objects to obstruct airow in and out of the server. In
addition, if you are using a front bezel, make sure the bezel's lter is replaced
periodically.
2. Do not operate the server without drives or drive trays in the drive bays. Use
only recommended server parts.
3. Make sure no wires or foreign objects obstruct airow through the chassis.
Pull all excess cabling out of the airow path or use shorter cables.
Installation Complete
In most cases, the chassis power supply and fans are pre-installed. If you need to
install fans continue to the Systems Fan section of this chapter. If the chassis will be
installed into a rack, continue to the next chapter for rack installation instructions.
Page 33
4-13
Chapter 4: Chassis Setup and Maintenance
Up to seven heavy-duty fans may be used to provide cooling for the chassis. Four
fans are located on the front side of the fan bracket, and three optional fans may
be placed on the rear side of the fan bracket for cooling redundancy with E-ATX or
ATX motherboards. The fans circulate air through the chassis as a means of lower-
ing the chassis internal temperature. The SC219 fans are hot-swappable, enabling
the fans to be replaced without powering-down the system.
4-11 System Fans
Figure 4-12: System Fan
Release Tab
Replacing a System Fan
1. If necessary, open the chassis while the power is running to determine which
fan requires changing. (Never run the server for an extended period of time
with the chassis open.)
2. Press the fan release tab to lift the failed fan from the chassis and pull it
completely out of the chassis.
3. Place the new fan into the vacant space in the housing while making sure the
arrows on the top of the fan (indicating air direction) point in the same direc-
tion as the arrows on the other fans.
4. The fan will automatically begin running at the correct speed.
Page 34
SC219 Chassis Manual
4-14
Figure 4-13: Installing a Front System Fan
Figure 4-14: Installing an Optional System Fan
Page 35
4-15
Chapter 4: Chassis Setup and Maintenance
The SC219 chassis has redundant 920 Watt power supplies. The power modules
are hot-swappable, enabling them be changed without powering down the system.
These power supplies are auto-switching capable. This enables the power supply
to automatically sense and operate at a 100v to 240v input voltage. An amber light
will be illuminated on the power supply when the power is off. An illuminated green
light indicates that the power supply is operating.
4-12 Power Supply
Changing the Power Supply
1. Determine which power supply needs to be replaced and unplug the power
cord to that module.
2. Push the release tab on the back of the power supply as illustrated to release
the power module from the chassis.
3. While holding down the release tab, pull the power supply out using the
handle provided on the power module.
4. Replace the failed power module with the same model power supply.
5. Push the new power supply module into the power bay until the tab clicks into
the locked position.
6. Plug the AC power cord back into the module and the replacment power mod-
ule will automatically power-up.
Figure 4-15: Removing the Power Supply
Release Tab
Page 36
SC219 Chassis Manual
4-16
4-13 Power Distributor
The power distributor provides failover and power supply redundancy and is pre-
installed in the chassis. In the unlikely event that you have to replace the power
distributor, follow the steps below.
Changing the Power Distributor
1. Power down the server and unplug the power cord from the power module.
2. Remove all cable connections to the power supply from the motherboard,
backplane, and other components.
3. Remove both power supply modules.
4. Remove the three screws securing the power distributor.
5. Gently pull the power distributor from the chassis and carefully guide all of the
cables through the power distributor housing.
6. Slide the new power distributor module into the power distributor housing.
Make that you slide the cables through the bottom of the housing.
7. Reconnect all the power cables, replace the power supply, and insert the plug
into the power supply.
Figure 4-16 Installing the Power Distributor
Page 37
4-17
Chapter 4: Chassis Setup and Maintenance
Figure 4-17: Removing the Screws at the Top of the Backplane
4-14 Removing the Backplane
The SC219 chassis backplane is located behind the hard drives and in front of the
front system fans. In order to change jumper settings on the backplane, it may be
necessary to remove the backplane from the chassis.
Removing the Backplane from the Chassis
1. Power down and unplug the system from any power source.
2. Remove the chassis cover.
3. Disconnect the cabling to the backplane.
4. Remove all of the hard drives from the hard drive bays in the front of the
chassis
5. Remove the three upper screws at the top of the backplane, indicated by the
arrows below.
5
Page 38
SC219 Chassis Manual
4-18
6. Loosen but do not remove the three screws in the spring bar, located on the
oor of the chassis, indicated by the arrows below.
7. Gently ease the backplane up and out of the chassis.
Figure 4-18: Loosening the Spring Bar Screws in the Floor of the Chassis
6
Page 39
4-19
Chapter 4: Chassis Setup and Maintenance
4-15 Installing the Backplane
Installing the Backplane into the Chassis
1. Ensure that all of the hard drive carriers have been removed from the bays in
the front of the chassis and that the spring bar has been loosened as directed
in the previous section.
2. Slide the backplane into the chassis at a slight angle, pushing it up against
the side of the chassis.
3. Ease the backplane forward, against the front of the chassis. This will aid in
the alignment of the mounting holes.
4. Align the mounting holes in the backplane with the holes in the chassis.
Replace the three screws at the top of the backplane and the three screws in
the oor of the chassis.
5. Reconnect all cables and return the hard drive trays to their bays in the front
of the chassis.
Figure 4-19: Installing the Backplane
2
3
Page 40
SC219 Chassis Manual
4-20
Notes
Page 41
5-1
Chapter 5: Rack Installation
Chapter 5
Rack Installation
5-1 Overview
This chapter provides instructions for installing the mounting rails onto a rack and
installing the chassis into the mounting rails.
5-2 Unpacking the System
You should inspect the box which the chassis was shipped in and note if it was
damaged in any way. If the chassis itself shows damage, you should le a damage
claim with the carrier who delivered it.
Decide on a suitable location for the rack unit that will hold your chassis. It should
be situated in a clean, dust-free area that is well ventilated. Avoid areas where
heat, electrical noise and electromagnetic elds are generated. The system needs
to be placed near a grounded power outlet. Be sure to read the Rack and Server
Precautions in the next section.
5-3 Preparing for Setup
The box your chassis was shipped in should include two sets of rail assemblies and
the mounting screws needed for installing the system into the rack. Also included
is an optional square hole to round hole converter bracket, for use in racks with
round mounting holes. Please read this section in its entirety before you begin the
installation procedure outlined in the sections that follow.
Choosing a Setup Location
•Leave enough clearance in front of the rack to enable you to open the front
door completely (~25 inches).
•Leave approximately 30 inches of clearance in the back of the rack to allow for
sufcient airow and ease in servicing.
•This product is for installation only in a Restricted Access Location (dedicated
equipment rooms, service closets and the like).
Page 42
SC219 Chassis Manual
5-2
5-4 Warnings and Precautions
Rack Precautions
•Ensure that the leveling jacks on the bottom of the rack are fully extended to
the oor with the full weight of the rack resting on them.
•In single rack installations, stabilizers should be attached to the rack.
•In multiple rack installations, the racks should be coupled together.
•Always make sure that the rack is stable before extending a component from
the rack.
•You should extend only one component at a time - extending two or more si-
multaneously may cause the rack to become unstable.
General Server Precautions
•Review the electrical and general safety precautions that came with the com-
ponents you are adding to your chassis.
•Determine the placement of each component in the rack before you install the
rails.
•Install the heaviest server components on the bottom of the rack rst, and then
work upwards.
•Use a regulating uninterruptible power supply (UPS) to protect the server from
power surges, voltage spikes and to keep your system operating in case of a
power failure.
•Allow the hot plug hard drives and power supply modules to cool before touch-
ing them.
Warning!
! !
Page 43
5-3
Chapter 5: Rack Installation
•Always keep the rack's front door and all panels and components on the servers
closed when not servicing to maintain proper cooling.
5-5 Rack Mounting Considerations
Ambient Operating Temperature
If installed in a closed or multi-unit rack assembly, the ambient operating tempera-
ture of the rack environment may be greater than the ambient temperature of the
room. Therefore, consideration should be given to installing the equipment in an
environment compatible with the manufacturer’s maximum rated ambient tempera-
ture (TMRA).
ReducedAirow
Equipment should be mounted into a rack so that the amount of airow required
for safe operation is not compromised.
Mechanical Loading
Equipment should be mounted into a rack so that a hazardous condition does not
arise due to uneven mechanical loading.
Circuit Overloading
Consideration should be given to the connection of the equipment to the power
supply circuitry and the effect that any possible overloading of circuits might have
on overcurrent protection and power supply wiring. Appropriate consideration of
equipment nameplate ratings should be used when addressing this concern.
Reliable Ground
A reliable ground must be maintained at all times. To ensure this, the rack itself
should be grounded. Particular attention should be given to power supply connec-
tions other than the direct connections to the branch circuit (for example. the use
of power strips, etc.).
Page 44
SC219 Chassis Manual
5-4
5-6 Rack Mounting Instructions
This section provides information on installing the chassis into a rack unit with the
rails provided. There are a variety of rack units on the market, which may mean
that the assembly procedure will differ slightly from the instructions provided. You
should also refer to the installation instructions that came with the rack unit you are
using. NOTE: This rail will t a rack between 26.5" and 36.4" deep.
Identifying the Sections of the Rack Rails
The chassis package includes two rail assemblies in the rack mounting kit. Each
assembly consists of three sections: An inner chassis rail which secures directly to
the chassis, an outer rail that secures to the rack, and a middle rail which extends
from the outer rail. These assemblies are specically designed for the left and right
side of the chassis.
Figure 5-1: Identifying the Outer Rail, Middle Rail and Inner Rails
(Left Rail Assembly Shown)
Inner Rail
Rail Assembly
(Shown with Rails
Retracted)
This Side Faces
Outward
Locking Tab
Middle Rail
Outer Rail
Page 45
5-5
Chapter 5: Rack Installation
Figure 5-2: Extending and Releasing the Inner Rail
1
2
1
1
1
3
1
4
Locking Tabs
Each inner rail has a locking tab. This tab locks the chassis into place when installed
and pushed fully into the rack. These tabs also lock the chassis in place when fully
extended from the rack. This prevents the server from coming completely out of
the rack when when the chassis is pulled out for servicing.
Releasing the Inner Rail
Releasing Inner Rail from the Outer Rails
1. Identify the left and right outer rail assemblies as described on page 5-4.
2. Pull the inner rail out of the outer rail until it is fully extended as illustrated
below.
3. Press the locking tab down to release the inner rail.
4. Repeat steps 1-3 for the second outer rail.
Page 46
SC219 Chassis Manual
5-6
Figure 5-4: Inner Rails Installed on the Chassis
Figure 5-3: Installing the Inner Rails
Installing The Inner Rails on the Chassis
Installing the Inner Rails
1. Conrm that the left and right inner rails have been correctly identied.
2. Place the inner rail rmly against the side of the chassis, aligning the hooks
on the side of the chassis with the holes in the inner rail.
3. Slide the inner rail forward toward the front of the chassis until the rail clicks
into the locked position, which secures the inner rail to the chassis.
4. Secure the inner rail to the chassis with the screws provided.
5. Repeat steps 1 through 4 above for the other inner rail.
3
1
4
1
4
2
Inner Rails
Page 47
5-7
Chapter 5: Rack Installation
Installing the Outer Rails on the Rack
Installing the Outer Rails
1. Press upward on the locking tab at the rear end of the middle rail.
2. Push the middle rail back into the outer rail.
3. Hang the hooks of the front of the outer rail onto the slots on the front of
the rack. If necessary, use screws to secure the outer rails to the rack, as
illustrated above.
4. Pull out the rear of the outer rail, adjusting the length until it ts within the
posts of the rack.
5. Hang the hooks of the rear portion of the outer rail onto the slots on the rear
of the rack. If necessary, use screws to secure the rear of the outer rail to the
rear of the rack.
6. Repeat steps 1-5 for the remaining outer rail.
Figure 5-5: Extending and Releasing the Outer Rails
1
1
1
2
1
3
1
4
Page 48
SC219 Chassis Manual
5-8
Figure 5-6: Installing into a Rack
Standard Chassis Installation
Installing the Chassis into a Rack
1. Conrm that the inner rails are properly installed on the chassis.
2. Conrm that the outer rails are correctly installed on the rack.
3. Pull the middle rail out from the front of the outer rail and make sure that the
ball-bearing shuttle is at the front locking position of the middle rail.
4. Align the chassis inner rails with the front of the middle rails.
5. Slide the inner rails on the chassis into the middle rails, keeping the pressure
even on both sides, until the locking tab of the inner rail clicks into the front of
the middle rail, locking the chassis into the fully extended position.
6. Depress the locking tabs of both sides at the same time and push the chassis
all the way into the rear of the rack.
7. If necessary for security purposes, use screws to secure the chassis handles
to the front of the rack.
Ball-Bearing
Shuttle
Page 49
5-9
Chapter 5: Rack Installation
Optional Quick Installation Method
The following quick installation method may be used to install the chassis onto a
rack.
Installing the Chassis into a Rack
1. Install the whole rail assembly onto the rack as described on page 5-7.
2. Release the inner rail without retracting the middle rail.
3. Install the inner rails on the chassis as previously described on page 5-6.
4. Install the chassis onto the middle rail as described in the previous section.
Page 50
SC219 Chassis Manual
5-10
Notes
Page 51
A-1
Appendix A: Chassis Cables
Appendix A
SC219 Chassis Cables
A-1 Overview
This appendix lists supported cables for your chassis system. It only includes the
most commonly used components and congurations. For more compatible cables,
refer to the manufacturer of the motherboard you are using and our Web site at:
www.supermicro.com.
A-2 Optional iPass cables for the SC219 (SAS/SATA)
SC219A-R920LPB, SC219A-R920UB
Part # Type Length Description
CBL-0281L Cable 75 cm
SFF 8087 to SFF 8087 Internal Backplane Cable
CBL-0108L-02 Cable 39 cm
SFF 8087 to SFF 8087 Internal Backplane Cable
Page 52
SC219 Chassis Manual
A-2
A-3 Compatible Cables
These cables are compatible with the SC219 Chassis.
Alternate SAS/SATA Cables
Some compatible motherboards have different connectors. If your motherboard
has only one SAS connector that the SAS/SATA cables must share, use one of the
following cables. These cables must be purchased separately.
Description: This cable has one iPass (SFF-8087/Mini-SAS) connector (36-pin) at
one end and four SATA connectors with a sideband on the other end. This cable
connects from the host motherboard SATA ports to the backplane SAS hard drive
iPass port if the motherboard has only SATA connectors.
Cable Name: SAS/SATA Cable Quantity: 1
Part #: CBL-0116L Alt. Name: iPass or "Small Four"
Page 53
A-3
Appendix A: Chassis Cables
Extending Power Cables
Although Supermicro chassis are designed to be efcient and cost-effective, some
compatible motherboards have power connectors located in different areas.
To use these motherboards you may have to extend the power cables to the moth-
erboards. To do this, use the following chart as a guide.
Power Cable Extenders
Number of Pins Cable Part # Length
24-pin CBL-0042 7.9” (20 cm)
20-pin CBL-0059 7.9” (20 cm)
8-pin CBL-0062 7.9” (20 cm)
4-pin CBL-0060 7.9” (20 cm)
Front Panel to the Motherboard
The SC219 chassis includes a cable to connect the chassis front panel to the
motherboard. If your motherboard uses a different connector, use the following list
to nd a compatible cable.
Front Panel to Motherboard Cable (Ribbon Cable)
Number of Pins
(Front Panel)
Number of Pins
(Motherboard
Cable Part #
16-pin 16-pin CBL-0049
16-pin 20-pin CBL-0048
20-pin 20-pin CBL-0047
16-pin Varies* CBL-0068
20-pin Varies* CBL-0067
* Split cables: Use these cables if your motherboard requires several different con-
nections from the front panel.
Page 54
SC219 Chassis Manual
A-4
Notes
Page 55
B-1
Appendix B: Power Supply Specications
Appendix B
SC219PowerSupplySpecications
This appendix lists power supply specications for the SC219 system.
SC219A-R920LPB, SC219A-R920UB, SC219A-R920WB
920W
MFR Part # PWS-920P-1R
AC Input
100 - 240V 50 - 60Hz 11 - 4.5 Amp
DC Output
4 Amp @ +5V standby 75 Amp @ +12V
With Power
Distributor
+5V: 50 Amp +3.3V: 30 Amp
-12V: 0.6 Amp
Page 56
SC219 Chassis Manual
B-2
Notes
Page 57
C-1
Appendix C: SAS-213A Backplane Specications
Appendix C
SAS-213ABackplaneSpecications
To avoid personal injury and property damage, carefully follow all the safety steps
listed below when accessing your system or handling the components.
C-1 ESD Safety Guidelines
Electrostatic Discharge (ESD) can damage electronic com ponents. To prevent dam-
age to your system, it is important to handle it very carefully. The following measures
are generally sufcient to protect your equipment from ESD.
•Use a grounded wrist strap designed to prevent static discharge.
•Touch a grounded metal object before removing a component from the antistatic
bag.
•Handle the backplane by its edges only; do not touch its components, peripheral
chips, memory modules or gold contacts.
•When handling chips or modules, avoid touching their pins.
•Put the card and peripherals back into their antistatic bags when not in use.
C-2 General Safety Guidelines
•Always disconnect power cables before installing or removing any components
from the computer, including the backplane.
•Disconnect the power cable before installing or removing any cables from the
backplane.
•Make sure that the backplane is securely and properly installed on the mother-
board to prevent damage to the system due to power shortage.
Page 58
C-2
SC219 Chassis Manual
C-3 A Note to Users
•All images and layouts shown in this user's guide are based upon the latest PCB
Revision available at the time of publishing. The card you have received may or
may not look exactly the same as the graphics shown in this manual.
C-4 Introduction to the SAS-213A Backplane
The SAS-213A backplane has been designed to utilize the most up-to-date technol-
ogy available, providing your system with reliable, high-quality performance.
This manual reects SAS-213A Revision 1.00, the most current release available at
the time of publication. Always refer to the Supermicro Web site at www.supermicro.
com for the latest updates, compatible parts and supported congurations.
Page 59
C-3
Appendix C: SAS-213A Backplane Specications
C-5 Front Connectors and Jumpers
Front Connectors
Y2
C6
C5C47 C44
C201
C197
JP78
JP69
JP13
JP10
JP46JP48
JP37
JP52
JP95
JP96
JP35
JP36
JP84
R132
R131
R125
R123
R392
R169
R351
R365
R124
R126
R302
R303
R624
JP18
JP80
F3
C213
C212
C133
C132
C139
C380
C130
C35
JSM1
JP26
JP27
JSM2JSM3
JSM4
MH2MH1 MH3
+
+
+
+
+
+
+
652
1
65
2
1
4
1
4
1
4
1
41
3
1
3
1
3
1
1
1
+
+
A1
B1
A18
B18
BAR CODE
1.00
SAS213A
REV:
DESIGNED IN USA
SAS IN#1
SAS IN#2
SAS IN#3SAS IN#4
I2C ADDR
JP80
ON:C0 OFF:C2
UPGRADE#2
JP78:
I2C#4
JP36 9072#2 RST 1-2:RST 2-3:NO RST
I2C#3
I2C#2
9072#1 RST
JP35
1-2:RST 2-3:NO RST
UPGRADE#1
JP69:
2-3:I2C
1-2:SGPIO
JP84 MODE
I2C#1
BUZZER RST
R6
R7 D3 D4
BZ1
C
A
C
A
1
2
6
4
3
8
5
11
10
9
7
12
1
6 6
6
1. Upgrade Connectors JP69 and
JP78
2. I2C Connector #1 (JP37)
3. I2C Connector #2 (JP95)
4. I2C Connector #3 (JP52)
5. I2C Connector #4 (JP96)
6. Power Connectors (4-pin): JP10,
JP13, JP46, JP48
7. SAS IN#1 JSM1
8. SAS IN#2 JSM2
9. SAS IN#3 JSM3
10. SAS IN#4 JSM4
11. JP27 Activity LED #2
12. JP26 Activity LED #1
Figure C-1: Front Connectors and Jumpers
Page 60
C-4
SC219 Chassis Manual
C-6 FrontConnectorandPinDenitions
1. Upgrade Connectors
The upgrade connectors are designated JP69,
and JP78 are used for manufacturer's diagnos-
tic purposes only.
2. - 5. I2C Connectors
The I2C Connectors, designated JP37, JP95,
JP52 and JP96 are used to monitor HDD ac-
tivity and status. See the table on the right for
pin denitions.
I2C Connector
PinDenitions
Pin# Denition
1 Data
2 Ground
3 Clock
4 No Connection
Backplane
Main Power
4-Pin Connector)
Pin# Denition
1
+12V
2 and 3 Ground
4 +5V
6. Backplane Main Power Connectors
The 4-pin connectors, designated JP10,
JP13, JP46 and JP48 provide power to the
backplane. See the table on the right for pin
denitions.
7. - 10. SAS IN Ports (Sideband included)
The SAS ports are used to connect the SAS
drive cables. The four SAS IN ports are des-
ignated #JSM1 - #JSM4. Each port is also
compatible with SATA drives.
SidebandDenitions
Pin # Denition Pin # Denition
A11 SGPIO:
SDIN
I2C:
Backplane Addressing (SB5)
B11 Controller ID
(SB6)
A12 SGPIO:
SDOUT
I2C: Reset (SB4)
B10 GND (SB2)
A9 GND (SB3) B9 SGPIO:
SLOAD
I2C:SDA (SB1)
A8 Backplane
ID (SB7)
B8 SGPIO:
SCLOCK
I2C:SCL (SB0)
Page 61
C-5
Appendix C: SAS-213A Backplane Specications
11. - 12. ACT_IN:
The activity LED connectors, designated JP26,
and JP27 are used to indicate the activity
status of each SAS drive. The activity LED
connector is located on the front panel. For
the activity LED connector to work properly,
connect using a 10-pin LED cable. This is only
used when the activity LED is not supported by
the hard drive.
SAS Activity LED Header
PinDenitions
Pin# Denition Pin# Denition
1 ACT IN#0 6 ACT IN#4
2 ACT IN#1 7 ACT IN#5
3 ACT IN#2 8 ACT IN#6
4 ACT IN#3 9 ACT IN#7
5 Ground X Empty
SAS Activity LED Header
PinDenitions
Pin# Denition Pin# Denition
1 ACT IN#8 6 ACT IN#12
2 ACT IN#9 7 ACT IN#13
3 ACT IN#10 8 ACT IN#14
4 ACT IN#11 9 ACT IN#15
5 Ground X Empty
Page 62
C-6
SC219 Chassis Manual
13. JP80 I2C Addr On C0, Off C2 (Not populated)
14. Chip Reset JP36 1-2 Reset, 2-3 No Reset (Not populated)
15. Buzzer Reset* JP18
16. JP84 1-2 SGPIO, 2-3 I2C
17. Chip Reset JP35 1-2 Reset, 2-3 No Reset (Not populated)
C-7 Front JumperLocationsandPinDenitions
Y2
C6
C5C47 C44
C201
C197
JP78
JP69
JP13
JP10
JP46JP48
JP37
JP52
JP95
JP96
JP35
JP36
JP84
R132
R131
R125
R123
R392
R169
R351
R365
R124
R126
R302
R303
R624
JP18
JP80
F3
C213
C212
C133
C132
C139
C380
C130
C35
JSM1
JP26
JP27
JSM2JSM3
JSM4
MH2MH1 MH3
+
+
+
+
+
+
+
652
1
65
2
1
4
1
4
1
4
1
41
3
1
3
1
3
1
1
1
+
+
A1
B1
A18
B18
BAR CODE
1.00
SAS213A
REV:
DESIGNED IN USA
SAS IN#1
SAS IN#2
SAS IN#3SAS IN#4
I2C ADDR
JP80
ON:C0 OFF:C2
UPGRADE#2
JP78:
I2C#4
JP36 9072#2 RST
1-2:RST
2-3:NO RST
I2C#3
I2C#2
9072#1 RST
JP35
1-2:RST
2-3:NO RST
UPGRADE#1
JP69:
2-3:I2C
1-2:SGPIO
JP84 MODE
I2C#1
BUZZER RST
R6
R7 D3 D4
BZ1
C
A
C
A
15
16
17
13
14
Explanation of Jumpers
To modify the operation of the backplane,
jumpers can be used to choose between
optional settings. Jumpers create shorts
between two pins to change the function
of the connector. Pin 1 is identied with
a square solder pad on the printed circuit
board. Note: On two pin jumpers, "Closed"
means the jumper is on and "Open" means
the jumper is off the pins.
Connector
Pins
Jumper
Setting
3 2 1
3 2 1
Figure C-2: Front Jumpers
*The buzzer sound indicates that a condition requiring immediate attention has
occurred.
The buzzer alarm is triggered by the following conditions:
1. Hard drive failure
2. Fan failure
3. System temperature over 45º Celsius.
Page 63
C-7
Appendix C: SAS-213A Backplane Specications
I2C and SGPIO Modes and Jumper Settings
This backplane can utilize I2C or SGPIO. SGPIO is the default mode and can be
used without making changes to your jumper. The following information details
which jumper must be congured to use SGPIO mode or restore your backplane
to I2C mode.
SGPIO Setting (Default)
Jumper Jumper Setting Note
JP84 1-2 SGPIO Mode Setting
I2C Setting
Jumper Jumper Setting Note
JP84 2-3 I2C Setting
Page 64
C-8
SC219 Chassis Manual
Y2
C6
C5C47 C44
C201
C197
JP78
JP69
JP13
JP10
JP46JP48
JP37
JP52
JP95
JP96
JP35
JP36
JP84
R132
R131
R125
R123
R392
R169
R351
R365
R124
R126
R302
R303
R624
JP18
JP80
F3
C213
C212
C133
C132
C139
C380
C130
C35
JSM1
JP26
JP27
JSM2JSM3
JSM4
MH2MH1 MH3
+
+
+
+
+
+
+
652
1
65
2
1
4
1
4
1
4
1
41
3
1
3
1
3
1
1
1
+
+
A1B1A18
B18
BAR CODE
1.00
SAS213A
REV:
DESIGNED IN USA
SAS IN#1
SAS IN#2
SAS IN#3SAS IN#4
I2C ADDR
JP80
ON:C0 OFF:C2
UPGRADE#2
JP78:
I2C#4
JP36
9072#2 RST
1-2:RST
2-3:NO RST
I2C#3
I2C#2
9072#1 RST
JP35
1-2:RST 2-3:NO RST
UPGRADE#1
JP69:
2-3:I2C
1-2:SGPIO
JP84 MODE
I2C#1
BUZZER RST
R6
R7 D3 D4
BZ1
C
A
C
A
Front Panel LEDs
LED State Specication
D3 On Alarm #1
D4 On Alarm #2
Front LED Indicators
R624
+
R6
R7 D3 D4
BZ1
C
A
C
A
D3
D4
Figure C-3: Front LEDs
Page 65
C-9
Appendix C: SAS-213A Backplane Specications
RP3
RP6
R301
R90
R89
R87
R86
R83
R468
R467
R466
R465
R464
R461
R460
R435
R428
R253
R251
R250
R215
R214
R213
R180
R179
R178
R175
R174
R173
R165
R164
R85
R84
R463
R614
F13
F14
F15
F16
D87
D42
D41
D40
D26
D25
D24
D22
D15
D14
D13
D12
D111
D106
D104
D102
D88
D8
D7
D6
D5
D39
D38
D37
D31
D30
D29
D23
D110
D109
D108
D107
C107
U21
U19
J31
J35
J3
J27
J21
J1
J43
J4
J37
J28
J2
J33
J18
J17
J15
J13
C
A
C
A
C
A
C
A
C
A
C
A
C
A
C
A
C
A
C
A
C
A
C
A
C
A
C
A
C
A
C
A
C
A
C
A
C
A
C
A
C
A
C
A
C
A
C
A
C
A
C
A
C
A
C
A C
A
C
A
C
A
C
A
1
16
17
32
33
48
1
33
48
22
21
33
27
8
7
9
22
21
33
27
8
7
9
22
21
33
27
87 9
22
21
33
27
8
7
9
22
21
33
27
8
7
9
22
21
33
27
87 9
22
21
33
27
87 9
22
21
33
27
8
7
9
22
21
33
27
8
7
9
22
21
33
27
87 9
22
21
33
27
8
7
9
22
21
33
27
87 9
22
21
33
27
8
7
9
22
21
33
27
8
7
9
22
21
33
27
8
7
9
22
21
33
27
8
7
9
SAS #0
SAS #1
SAS #2
SAS #3
SAS #4
SAS #5
SAS #6
SAS #7
SAS #8
SAS #9
SAS #10
SAS #11
SAS #12
SAS #13
SAS #14
SAS #15
FAIL#0
ACT#0
FAIL#1
ACT#1
FAIL#2
ACT#2
FAIL#3
ACT#3
FAIL#4
ACT#4
FAIL#5
ACT#5
FAIL#6
ACT#6
FAIL#7
ACT#7
FAIL#8
ACT#8
FAIL#9 ACT#9
FALI#10
ACT#10
FAIL#11
ACT#11
FAIL#12
ACT#12
FAIL#13 ACT#13
FAIL#14 ACT#14
FAIL#15
ACT#15
C-7 Rear Components, Connectors and LED Indicators
Rear SAS/SATA Connectors
Rear
Connector
SAS Drive
Number
SAS #0 SAS/SATA HDD #0
SAS #1 SAS/SATA HDD #1
SAS #2 SAS/SATA HDD #2
SAS #3 SAS/SATA HDD #3
SAS #4
SAS/SATA HDD #4
SAS #5 SAS/SATA HDD #5
SAS #6 SAS/SATA HDD #6
SAS #7 SAS/SATA HDD #7
SAS #8 SAS/SATA HDD #8
SAS #9 SAS/SATA HDD #9
SAS #10 SAS/SATA HDD #10
SAS #11 SAS/SATA HDD #11
SAS #12 SAS/SATA HDD #12
SAS #13 SAS/SATA HDD #13
SAS #14 SAS/SATA HDD #14
SAS #15 SAS/SATA HDD #15
SAS #12
SAS #13
SAS #9
SAS #15
SAS #11
SAS #7
SAS #3
SAS #5
SAS #14
SAS #10
SAS #6
SAS #2
SAS #1
SAS #8
SAS #4
SAS #0
Figure C-4 Rear Connectors
Page 66
C-10
SC219 Chassis Manual
Rear LED Indicators
Rear LED Hard Drive Activity Failure LED
SAS #0 D12 D5
SAS #1 D22 D23
SAS #2 D40 D37
SAS #3 D102 D107
SAS #4 D13 D6
SAS #5 D24 D29
SAS #6 D41 D38
SAS #7 D104 D108
SAS #8 D14 D7
SAS #9 D25 D30
SAS #10 D42 D39
SAS #11 D106 D109
SAS #12 D15 D8
SAS #13 D26 D31
SAS #14 D87 D88
SAS #15 D111 D110
Page 67
C-11
Appendix C: SAS-213A Backplane Specications
Notes
Page 68
C-12
SC219 Chassis Manual
Disclaimer (cont.) The products sold by Supermicro are not intended for and will not be used in life sup­port systems, medical equipment, nuclear facilities or systems, aircraft, aircraft devices, aircraft/emergency communication devices or other critical systems whose failure to per-
form be reasonably expected to result in signicant injury or loss of life or catastrophic
property damage. Accordingly, Supermicro disclaims any and all liability, and should buyer use or sell such products for use in such ultra-hazardous applications, it does so entirely at its own risk. Furthermore, buyer agrees to fully indemnify, defend and hold Supermicro harmless for and against any and all claims, demands, actions, litigation, and proceedings of any kind arising out of or related to such ultra-hazardous use or sale.
Loading...