Supero AS1021M-T2R User Manual

®
SUPER
AS1021M-T2R
USER’S MANUAL
1.0a
The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccuracies that may be contained in this document, makes no commitment to update or to keep current the information in this manual, or to notify any person or organization of the updates. Please Note: For the most up-to-date version of this
manual, please see our web site at www.supermicro.com.
Super Micro Computer, Inc. reserves the right to make changes to the product described in this manual at any time and without notice. This product, including software, if any, and documenta­tion may not, in whole or in part, be copied, photocopied, reproduced, translated or reduced to any medium or machine without prior written consent.
IN NO EVENT WILL SUPERMICRO BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL, SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO USE THIS PRODUCT OR DOCUMENTATION, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. IN PARTICULAR, SUPERMICRO SHALL NOT HAVE LIABILITY FOR ANY HARDWARE, SOFTWARE, OR DATA STORED OR USED WITH THE PRODUCT, INCLUDING THE COSTS OF REPAIRING, REPLACING, INTEGRATING, INSTALLING OR RECOVERING SUCH HARDWARE, SOFTWARE, OR DATA.
Any disputes arising between manufacturer and customer shall be governed by the laws of Santa Clara County in the State of California, USA. The State of California, County of Santa Clara shall be the exclusive venue for the resolution of any such disputes. Supermicro's total liability for all claims will not exceed the price paid for the hardware product.
FCC Statement: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the manufacturer’s instruction manual, may cause harmful interference with radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case you will be required to correct the interference at your own expense.
WARNING: Handling of lead solder materials used in this product may expose you to lead, a chemical known to the State of California to cause birth defects and other reproductive harm.
Manual Revision 1.0a
Release Date: August 31, 2007
Unless you request and receive written permission from Super Micro Computer, Inc., you may not copy any part of this document.
Information in this document is subject to change without notice. Other products and companies referred to herein are trademarks or registered trademarks of their respective companies or mark holders.
Copyright © 2007 by Super Micro Computer, Inc. All rights reserved.
Printed in the United States of America
Preface
About This Manual
This manual is written for professional system integrators and PC technicians. It
provides information for the installation and use of the AS1021M-T2R. Installation
and maintainance should be performed by experienced technicians only.
The AS1021M-T2R is a 1U server based on the SC815TQ-R650 rackmount chassis
and the Super H8DMR-i2, a dual processor serverboard that supports AMD Socket
F type processors and up to 16 GB of registered ECC DDR2-667/533 or 32 GB of
registered ECC DDR2-400 SDRAM.
Preface
Manual Organization
Chapter 1: Introduction
The fi rst chapter provides a checklist of the main components included with the
server system and describes the main features of the H8DMR-i2 serverboard and
the SC815TQ-R650 chassis, which comprise the AS1021M-T2R.
Chapter 2: Server Installation
This chapter describes the steps necessary to install the AS1021M-T2R into a rack
and check out the server confi guration prior to powering up the system. If your
server was ordered without processor and memory components, this chapter will
refer you to the appropriate sections of the manual for their installation.
Chapter 3: System Interface
Refer here for details on the system interface, which includes the functions and
information provided by the control panel on the chassis as well as other LEDs
located throughout the system.
iii
AS1021M-T2R User's Manual
Chapter 4: System Safety
You should thoroughly familiarize yourself with this chapter for a general overview
of safety precautions that should be followed when installing and servicing the
AS1021M-T2R.
Chapter 5: Advanced Serverboard Setup
Chapter 5 provides detailed information on the H8DMR-i2 serverboard, including the
locations and functions of connections, headers and jumpers. Refer to this chapter
when adding or removing processors or main memory and when reconfi guring the
serverboard.
Chapter 6: Advanced Chassis Setup
Refer to Chapter 6 for detailed information on the SC815TQ-R650 server chassis.
You should follow the procedures given in this chapter when installing, removing or
reconfi guring SATA or peripheral drives and when replacing system power supply
modules and cooling fans.
Chapter 7: BIOS
The BIOS chapter includes an introduction to BIOS and provides detailed informa-
tion on running the CMOS Setup Utility.
Appendix A: BIOS Error Beep Codes
Appendix B: BIOS POST Checkpoint Codes
Appendix C: System Specifi cations
iv
Notes
Preface
v
AS1021M-T2R User's Manual
Table of Contents
Preface
About This Manual ...................................................................................................... iii
Manual Organization ................................................................................................... iii
Chapter 1: Introduction
1-1 Overview ......................................................................................................... 1-1
1-2 Serverboard Features ..................................................................................... 1-2
1-3 Server Chassis Features ................................................................................ 1-3
1-4 Contacting Supermicro ................................................................................... 1-6
Chapter 2: Server Installation
2-1 Overview .......................................................................................................... 2-1
2-2 Unpacking the System ................................................................................... 2-1
2-3 Preparing for Setup ......................................................................................... 2-1
Choosing a Setup Location .................................................................... 2-2
Rack Precautions .................................................................................... 2-2
Server Precautions ................................................................................. 2-2
Rack Mounting Considerations ............................................................... 2-3
2-4 Installing the System into a Rack .................................................................... 2-4
2-5 Checking the Serverboard Setup .................................................................... 2-8
2-6 Checking the Drive Bay Setup ...................................................................... 2-10
Chapter 3: System Interface
3-1 Overview ......................................................................................................... 3-1
3-2 Control Panel Buttons .................................................................................... 3-1
Reset ....................................................................................................... 3-1
Power ...................................................................................................... 3-1
3-3 Control Panel LEDs ........................................................................................ 3-2
Overheat/Fan Fail .................................................................................. 3-2
NIC2 ........................................................................................................ 3-2
NIC1 ........................................................................................................ 3-2
HDD ........................................................................................................ 3-2
Power ...................................................................................................... 3-3
3-4 Drive Carrier LEDs ......................................................................................... 3-3
vi
Table of Contents
Chapter 4: System Safety
4-1 Electrical Safety Precautions ........................................................................... 4-1
4-2 General Safety Precautions ............................................................................. 4-2
4-3 ESD Precautions ............................................................................................ 4-3
4-4 Operating Precautions .................................................................................... 4-4
Chapter 5: Advanced Serverboard Setup
5-1 Handling the Serverboard ................................................................................ 5-1
5-2 Processor and Heatsink Installation ................................................................ 5-2
5-3 Connecting Cables .......................................................................................... 5-5
Connecting Data Cables ........................................................................... 5-5
Connecting Power Cables ......................................................................... 5-5
Connecting the Control Panel ................................................................... 5-6
5-4 I/O Ports ......................................................................................................... 5-7
5-5 Installing Memory ............................................................................................. 5-7
5-6 Adding PCI Cards .......................................................................................... 5-10
5-7 Serverboard Details ...................................................................................... 5-11
H8DMR-i2 Layout ................................................................................... 5-11
H8DMR-i2 Quick Reference .................................................................. 5-12
5-8 Connecting Cables ....................................................................................... 5-13
ATX Power Connector .......................................................................... 5-13
Processor Power Connector ................................................................... 5-13
Auxiliary Power Connector ..................................................................... 5-13
NMI Button ............................................................................................ 5-13
Power LED ............................................................................................. 5-14
HDD LED .............................................................................................. 5-14
NIC1/NIC2 LEDs ................................................................................... 5-14
Overheat/Fan Fail LED .......................................................................... 5-14
Power Fail LED ...................................................................................... 5-15
Reset Button .......................................................................................... 5-15
Power Button ........................................................................................ 5-15
Universal Serial Bus (USB0/1) Ports ..................................................... 5-15
Extra USB Headers ................................................................................. 5-16
Serial Ports ............................................................................................. 5-16
Fan Headers ............................................................................................ 5-16
LAN1/2 (Ethernet Ports) ......................................................................... 5-16
Power LED/Speaker ................................................................................ 5-17
ATX PS/2 Keyboard and PS/2 Mouse Ports ......................................... 5-17
Chassis Intrusion .................................................................................... 5-17
vii
AS1021M-T2R User's Manual
Overheat LED ........................................................................................ 5-17
Wake-On-LAN ........................................................................................ 5-18
Wake-On-Ring ......................................................................................... 5-18
PWR I
2
C ................................................................................................. 5-18
IPMB ....................................................................................................... 5-18
3rd Power Supply Alarm Reset Header ................................................. 5-19
Compact Flash Card PWR Connector ................................................... 5-19
SGPIO .................................................................................................... 5-19
Power Fail Header ................................................................................. 5-20
5-9 Jumper Settings ............................................................................................. 5-20
Explanation of Jumpers ........................................................................... 5-20
CMOS Clear ............................................................................................ 5-21
3rd Power Supply Fail Detect Enable/Disable ....................................... 5-21
VGA Enable/Disable ................................................................................ 5-21
Watch Dog ............................................................................................... 5-22
PCI-X Slot Frequency Select ................................................................. 5-22
2
I
C to PCI Enable/Disable ...................................................................... 5-22
Compact Flash Master/Slave ................................................................. 5-23
5-10 Onboard Indicators ........................................................................................ 5-24
LAN1/2 LEDs ........................................................................................... 5-24
+5V Standby Power LED ....................................................................... 5-24
5-11 Floppy, IDE and SATA Drive Connections ..................................................... 5-25
Floppy Connector .................................................................................... 5-25
IDE Connector ......................................................................................... 5-26
SATA Ports ............................................................................................. 5-26
Chapter 6: Advanced Chassis Setup
6-1 Static-Sensitive Devices .................................................................................. 6-1
6-2 Control Panel ................................................................................................... 6-2
6-3 System Fans .................................................................................................... 6-3
System Fan Failure ................................................................................... 6-3
Replacing System Cooling Fans ............................................................... 6-3
6-4 Drive Bay Installation/Removal ........................................................................ 6-4
SATA Drive Installation .............................................................................. 6-6
DVD-ROM and Floppy Drive Installation .................................................. 6-8
6-5 Power Supply ................................................................................................... 6-9
Power Supply Failure ................................................................................ 6-9
Removing/Replacing the Power Supply .................................................... 6-9
viii
Table of Contents
Chapter 7: BIOS
7-1 Introduction ...................................................................................................... 7-1
7-2 Main Menu ...................................................................................................... 7-2
7-3 Advanced Settings Menu ............................................................................... 7-2
7-4 Boot Menu .................................................................................................... 7-16
7-5 Security Menu ............................................................................................... 7-17
7-6 Exit Menu ...................................................................................................... 7-18
Appendices:
Appendix A: BIOS Error Beep Codes
Appendix B: BIOS POST Checkpoint Codes
Appendix C: System Specifi cations
ix
AS1021M-T2R User's Manual
Notes
x
Chapter 1: Introduction
Chapter 1
Introduction
1-1 Overview
The AS1021M-T2R is a 1U server comprised of two main subsystems: the
SC815TQ-R650 server chassis and the H8DMR-i2 dual processor serverboard.
Please refer to our web site for information on operating systems that have been
certifi ed for use with the AS1021M-T2R (www.supermicro.com/aplus).
In addition to the serverboard and chassis, various hardware components have
been included with the AS1021M-T2R, as listed below:
One (1) slim fl oppy drive [FPD-TEAC-S(B)] (optional)
One (1) slim DVD-ROM drive [DVM-PNSC-824(B)]
Four (4) sets of 40-mm counter-rotating fans (FAN-0086L)
One (1) front control panel cable
One (1) rackmount kit (CSE-PT51L)
Riser Cards: (see Section 5-6 for details)
One (1) riser card (CSE-RR1U-XLP) for PCI-X add-on card
One (1) riser card (CSE-RR1U-X) for PCI-X add-on card
One (1) riser card (CSE-RR1U-ELP) for PCI-E add-on card
One (1) riser card (CSE-RR1U-EL) for PCI-E add-on card
 SATA Accessories
One (1) SATA backplane (CSE-SAS-815TQ)
SATA data cables: CBL-0044L x1, CBL-0178L x2, CBL-0179L x1)
One (1) SGPIO cable (CBL-0157L)
Four (4) SATA drive carriers [MCP-220-00001-03(01)]
One (1) CD containing drivers and utilities
AS1021M-T2R User's Manual
1-1
AS1021M-T2R User's Manual
1-2 Serverboard Features
At the heart of the AS1021M-T2R lies the H8DMR-i2, a dual processor serverboard
based on nVidia's MCP55 Pro chipset. Below are the main features of the H8DMR-
i2 (see Figure 1-1 for a block diagram of the chipset).
Processors
The H8DMR-i2 supports single or dual AMD Socket F type processors. Please
refer to the serverboard description pages on our web site for a complete listing of
supported processors.
Memory
The H8DMR-i2 has eight 240-pin DIMM sockets that can support up to 16 GB of
registered ECC DDR2-667/533 or 32 GB of registered ECC DDR2-400 SDRAM.
The memory may be installed to provide an interleaved confi guration, which requires
modules of the same size and speed to be installed in pairs. Please refer to the
Installing Memory section for details.
Serial ATA
An on-chip SATA controller is integrated into the H8DMR-i2 to provide a six-port,
3 Gb/sec Serial ATA subsystem, which is RAID 0, 1 and 0+ 1 supported. The
SATA drives are hot-swappable units. Note: The operating system you use must
have RAID support to enable the hot-swap capability and RAID function of the
Serial ATA drives.
PCI Expansion Slots
The H8DMR-i2 has two Universal PCI slots, each of which support either one x8
PCI-Express slots or one PCI-X 133/100 MHz slot. One standard size PCI-X or
PCI-Express x8 add-on card and one low profi le PCI-X add-on card (all with riser
cards) may be used with the server.
Onboard Controllers/Ports
One fl oppy drive controller one onboard ATA/100 controller are provided to support
up to two IDE hard drives or ATAPI devices. The color-coded I/O ports include one
COM port, a VGA (monitor) port, two USB 2.0 ports, PS/2 mouse and keyboard
ports and two gigabit Ethernet ports.
1-2
Chapter 1: Introduction
ATI Graphics Controller
The H8DMR-i2 features an integrated ATI video controller based on the ES1000
graphics chip. The ES1000 was designed specifi cally for servers, featuring low
power consumption, high reliability and superior longevity.
Other Features
Other onboard features that promote system health include onboard voltage moni-
tors, a chassis intrusion header, auto-switching voltage regulators, chassis and CPU
overheat sensors, virus protection and BIOS rescue.
1-3 Server Chassis Features
The AS1021M-T2R is a high-end, scaleable server platform built upon the
SC815TQ-R650 1U server chassis. The following is a general outline of the main
features of the SC815TQ-R650 chassis.
System Power
The SC815TQ-R650 features a single 560W cold-swap power supply. Power must
be removed from the system before servicing or replacing the power supply.
SATA Subsystem
The SC815TQ-R650 chassis was designed to support four SATA hard drives, which
are hot-swappable units. Note: The operating system you use must have RAID
support to enable the hot-swap capability of the SATA drives.
PCI Expansion Slots
One standard size and one low-profi le PCI-X/PCI-E add-on card may be used with
the SC815TQ-R650 chassis.
Control Panel
The control panel on the SC815TQ-R650 provides you with system monitoring and
control. LEDs indicate system power, HDD activity, network activity (2) and over-
heat/fan failure. A main power button and system reset button is also included.
1-3
AS1021M-T2R User's Manual
I/O Backplane
The SC815TQ-R650 is an ATX form factor chassis that is designed to be used in
a 1U rackmount confi guration. Ports on the I/O backplane include one COM port,
a VGA port, two USB 2.0 ports, PS/2 mouse and keyboard ports and two gigabit
Ethernet ports.
Cooling System
The SC815TQ-R650 chassis has an innovative cooling design that features fi ve
sets of 40-mm counter-rotating fans located in the middle section of the chassis.
There is a "Fan Speed Control Mode" setting in BIOS that allows chassis fan speed
to be determined by system temperature. The power supply module also includes
a cooling fan.
1-4
Chapter 1: Introduction
Figure 1-1. nVidia MCP55 Pro Chipset:
System Block Diagram
Note: This is a general block diagram. Please see Chapter 5 for details.
DDR2-667/5 33/400 DDR2-667/533/400
DIMM 1B
DIMM 1A
DIMM 2B
DIMM 2A
PCI-X 133 MHz Slot
PCI-X 100 MHz Slot
128-bit data + 16-bit ECC
PCI-X
CH B
PCI-X
CH A
NEC uPD720400
AMD Opter on
Processor (CPU2)
TM
16 x 16 HT link (1 GHz)
x8 PCI-E Bus
AMD Opter on
Processor (CPU1)
MCP55 Pro
128-bit data + 16-bit ECC
TM
SATA Por ts (6)
IDE (ATA133)
USB Por ts (4)
AIC 7902W
ATI RN50
x8 PCI-E Slot
SCSI Por ts (2)
x8 PCI-E Slot
LPC
S I/O BIOS
Floppy
Kybd/
Mouse
Serial Ports
(2)
DIMM 2A
DIMM 2B
DIMM 1A
DIMM 1B
IPMI
1-5
AS1021M-T2R User's Manual
1-4 Contacting Supermicro
Headquarters
Address: Super Micro Computer, Inc. 980 Rock Ave. San Jose, CA 95131 U.S.A. Tel: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: marketing@supermicro.com (General Information) support@supermicro.com (Technical Support) Web Site: www.supermicro.com
Europe
Address: Super Micro Computer B.V. Het Sterrenbeeld 28, 5215 ML 's-Hertogenbosch, The Netherlands Tel: +31 (0) 73-6400390 Fax: +31 (0) 73-6416525 Email: sales@supermicro.nl (General Information) support@supermicro.nl (Technical Support) rma@supermicro.nl (Customer Support)
Asia-Pacifi c
Address: Super Micro, Taiwan 4F, No. 232-1, Liancheng Rd. Chung-Ho 235, Taipei County Taiwan, R.O.C. Tel: +886-(2) 8226-3990 Fax: +886-(2) 8226-3991 Web Site: www.supermicro.com.tw Technical Support: Email: support@supermicro.com.tw Tel: 886-2-8228-1366, ext.132 or 139
1-6
Chapter 2: Server Installation
Chapter 2
Server Installation
2-1 Overview
This chapter provides a quick setup checklist to get your AS1021M-T2R up and
running. Following these steps in the order given should enable you to have the
system operational within a minimum amount of time. This quick setup assumes
that your system has come to you with the processors and memory preinstalled. If
your system is not already fully integrated with a serverboard, processors, system
memory etc., please turn to the chapter or section noted in each step for details
on installing specifi c components.
2-2 Unpacking the System
You should inspect the box the AS1021M-T2R was shipped in and note if it was
damaged in any way. If the server itself shows damage you should fi le a damage
claim with the carrier who delivered it.
Decide on a suitable location for the rack unit that will hold the AS1021M-T2R. It
should be situated in a clean, dust-free area that is well ventilated. Avoid areas
where heat, electrical noise and electromagnetic fi elds are generated. You will also
need it placed near a grounded power outlet. Be sure to read the Rack and Server
Precautions in the next section.
2-3 Preparing for Setup
The box the AS1021M-T2R was shipped in should include two sets of rail assem-
blies, two rail mounting brackets and the mounting screws you will need to install the
system into the rack. Follow the steps in the order given to complete the installation
process in a minimum amount of time. Please read this section in its entirety before
you begin the installation procedure outlined in the sections that follow.
2-1
AS1021M-T2R User's Manual
Choosing a Setup Location
- Leave enough clearance in front of the rack to enable you to open the front door
completely (~25 inches).
- Leave approximately 30 inches of clearance in the back of the rack to allow for
suffi cient airfl ow and ease in servicing.
- This product is for installation only in a Restricted Access Location (dedicated
equipment rooms, service closets and the like).
- This product is not suitable for use with visual display work place devices according
to §2 of the the German Ordinance for Work with Visual Display Units.
!
Warnings and Precautions!
!
Rack Precautions
- Ensure that the leveling jacks on the bottom of the rack are fully extended to the
fl oor with the full weight of the rack resting on them.
- In single rack installation, stabilizers should be attached to the rack.
- In multiple rack installations, the racks should be coupled together.
- Always make sure the rack is stable before extending a component from the
rack.
- You should extend only one component at a time - extending two or more simul-
taneously may cause the rack to become unstable.
Server Precautions
- Review the electrical and general safety precautions in Chapter 4.
- Determine the placement of each component in the rack before you install the
rails.
- Install the heaviest server components on the bottom of the rack fi rst, and then
work up.
- Use a regulating uninterruptible power supply (UPS) to protect the server from
power surges, voltage spikes and to keep your system operating in case of a power
failure.
-
Allow the hot plug SATA drives and power supply modules to cool before touching
them.
-
Always keep the rack's front door and all panels and components on the servers
closed when not servicing to maintain proper cooling.
2-2
Chapter 2: Server Installation
Rack Mounting Considerations
Ambient Operating Temperature
If installed in a closed or multi-unit rack assembly, the ambient operating tempera-
ture of the rack environment may be greater than the ambient temperature of the
room. Therefore, consideration should be given to installing the equipment in an
environment compatible with the manufacturer’s maximum rated ambient tempera-
ture (Tmra).
Reduced Airfl ow
Equipment should be mounted into a rack so that the amount of airfl ow required
for safe operation is not compromised.
Mechanical Loading
Equipment should be mounted into a rack so that a hazardous condition does not
arise due to uneven mechanical loading.
Circuit Overloading
Consideration should be given to the connection of the equipment to the power
supply circuitry and the effect that any possible overloading of circuits might have
on overcurrent protection and power supply wiring. Appropriate consideration of
equipment nameplate ratings should be used when addressing this concern.
Reliable Ground
A reliable ground must be maintained at all times. To ensure this, the rack itself
should be grounded. Particular attention should be given to power supply connec-
tions other than the direct connections to the branch circuit (i.e. the use of power
strips, etc.).
2-3
AS1021M-T2R User's Manual
2-4 Installing the System into a Rack
This section provides information on installing the AS1021M-T2R into a rack unit with
the rack rails provided. If the system has already been mounted into a rack, you can
skip ahead to Sections 2-5 and 2-6. There are a variety of rack units on the market,
which may mean the assembly procedure will differ slightly. You should also refer
to the installation instructions that came with the rack unit you are using.
Identifying the Sections of the Rack Rails
You should have received two rack rail assemblies in the rack mounting kit. Each
assembly consists of two sections: an inner fi xed chassis rail that secures directly
to the server chassis and an outer fi xed rack rail that secures directly to the rack
itself (see Figure 2-1). Two pairs of short brackets to be used on the front side of
the outer rails are also included.
Installing the Inner Rails
Both the left and right side inner rails have been pre-attached to the chassis.
Proceed to the next step.
Figure 2-1. Identifying the Sections of the Rack Rails
(right side rail shown)
2-4
Chapter 2: Server Installation
Installing the Outer Rails
Begin by measuring the distance from the front rail to the rear rail of the rack. Attach
a short bracket to the front side of the right outer rail and a long bracket to the rear
side of the right outer rail. Adjust both the short and long brackets to the proper
distance so that the rail can fi t snugly into the rack. Secure the short bracket to the
front side of the outer rail with two M4 screws and the long bracket to the rear side
of the outer rail with three M4 screws. Repeat these steps for the left outer rail.
Locking Tabs
Both chassis rails have a locking tab, which serves two functions. The fi rst is to
lock the server into place when installed and pushed fully into the rack, which is
its normal position. Secondly, these tabs also lock the server in place when fully
extended from the rack. This prevents the server from coming completely out of
the rack when you pull it out for servicing.
Figure 2-2. Installing the Rack Rails
2-5
AS1021M-T2R User's Manual
Installing the Server into the Rack
You should now have rails attached to both the chassis and the rack unit. The next
step is to install the server into the rack. Do this by lining up the rear of the chas-
sis rails with the front of the rack rails. Slide the chassis rails into the rack rails,
keeping the pressure even on both sides (you may have to depress the locking
tabs when inserting). See Figure 2-3.
When the server has been pushed completely into the rack, you should hear the
locking tabs "click". Finish by inserting and tightening the thumbscrews that hold
the front of the server to the rack.
Figure 2-3. Installing the Server into a Rack
2-6
Chapter 2: Server Installation
Installing the Server into a Telco Rack
To install the AS1021M-T2R into a Telco type rack, use two L-shaped brackets on
either side of the chassis (four total). First, determine how far follow the server will
extend out the front of the rack. Larger chassis should be positioned to balance
the weight between front and back. If a bezel is included on your server, remove
it. Then attach the two front brackets to each side of the chassis, then the two
rear brackets positioned with just enough space to accommodate the width of the
telco rack. Finish by sliding the chassis into the rack and tightening the brackets
to the rack.
Figure 2-4. Installing the Server into a Telco Rack
2-7
AS1021M-T2R User's Manual
2-5 Checking the Serverboard Setup
After you install the AS1021M-T2R in the rack, you will need to open the top cover
to make sure the serverboard is properly installed and all the connections have
been made.
1. Accessing the inside of the System (see Figure 2-5)
First, release the retention screws that secure the system to the rack. Grasp the
two handles on either side and pull the system straight out until it locks (you will
hear a "click"). Next, depress the two buttons on the top of the chassis to release
the top cover (1). Push the cover away from you (toward the rear of the chassis)
until it stops (2). You can then lift the top cover from the chassis to gain full access
to the inside of the server.
To remove the system from the rack completely, depress the locking tabs in the
chassis rails (push the right-side tab down and the left-side tab up) to continue to
pull the system out past the locked position.
2. Check the CPUs (processors)
You may have one or two processors already installed in the serverboard. Each
processor needs its own heatsink. See Chapter 5 for instructions on processor and
heatsink installation.
3. Check the system memory
Your server system may have come with system memory already installed. Make
sure all DIMMs are fully seated in their slots. For details on adding system memory,
refer to Chapter 5.
4. Installing add-on cards
If desired, you can install add-on cards to the system. See Chapter 5 for details
on installing PCI add-on cards.
5. Check all cable connections and airfl ow
Make sure all power and data cables are properly connected and not blocking the
chassis airfl ow. See Chapter 5 for details on cable connections.
2-8
Chapter 2: Server Installation
Figure 2-5. Accessing the Inside of the System
2-9
AS1021M-T2R User's Manual
2-6 Checking the Drive Bay Setup
Next, you should check to make sure the peripheral drives and the SATA drives
and SATA backplane have been properly installed and all connections have been
made.
1. Accessing the drive bays
All drives are accessable from the front of the server. For servicing the DVD-
ROM and fl oppy drives, you will need to remove the top chassis cover. The SATA
disk drives can be installed and removed from the front of the chassis without
removing the top chassis cover.
2. DVD-ROM and fl oppy disk drives
A slim DVD-ROM and fl oppy drive should be preinstalled in your server. Refer
to Chapter 6 if you need to reinstall a DVD-ROM and/or fl oppy disk drive to the
system.
3. Check the SATA disk drives
Depending upon your system's confi guration, your system may have one or
more drives already installed. If you need to install SATA drives, please refer to
Chapter 6.
4. Check the airfl ow
Airfl ow is provided by four sets of 40-mm fans (each set of fans consists of two
fans that are mounted back to back). The system component layout was care-
fully designed to direct suffi cient cooling airfl ow to the components that generate
the most heat. Note that all power and data cables have been routed in such a
way that they do not block the airfl ow generated by the fans.
5. Supplying power to the system
The last thing you must do is to provide input power to the system. Plug the
power cords from the power supply modules into a high-quality power strip that
offers protection from electrical noise and power surges. It is recommended that
you use an uninterruptible power supply (UPS) source.
2-10
Chapter 3: System Interface
Chapter 3
System Interface
3-1 Overview
There are several LEDs on the control panel as well as others on the SATA drive
carriers to keep you constantly informed of the overall status of the system as well
as the activity and health of specifi c components. There are also two buttons on
the chassis control panel and an on/off switch on the power supply. This chapter
explains the meanings of all LED indicators and the appropriate response you
may need to take.
3-2 Control Panel Buttons
There are two push-buttons located on the front of the chassis. These are (in
order from left to right) a reset button and a power on/off button.
Reset:
Power: The main power button is used to apply or remove power from the
power supply to the server system. Turning off system power with this button
removes the main power but keeps standby power supplied to the system.
Use the reset button to reboot the system.
3-1
AS1021M-T2R User's Manual
3-3 Control Panel LEDs
The control panel located on the front of th SC815TQ-R650 chassis has fi ve LEDs.
These LEDs provide you with critical information related to different parts of the
system. This section explains what each LED indicates when illuminated and any
corrective action you may need to take.
Overheat/Fan Fail: When this LED fl ashes it indicates a fan failure. When
on continuously (on and not fl ashing) it indicates an overheat condition, which
may be caused by cables obstructing the airfl ow in the system or the ambient
room temperature being too warm. Check the routing of the cables and make
sure all fans are present and operating normally. You should also check to make
sure that the chassis covers are installed. Finally, verify that the heatsinks are
installed properly (see Chapter 5). This LED will remain fl ashing or on as long as
the overheat condition exists.
2
NIC2: Indicates network activity on LAN2 when fl ashing .
1
NIC1: Indicates network activity on LAN1 when fl ashing.
HDD: Indicates IDE channel activity. On the 1021M-T2R this light indicates
SATA and/or DVD-ROM drive activity when fl ashing.
3-2
Chapter 3: System Interface
Power: Indicates power is being supplied to the system's power supply
units. This LED should normally be illuminated when the system is operating.
3-4 Drive Carrier LEDs
Each Serial ATA drive carrier has two LEDs.
Green: When illuminated, the green LED on the front of the SATA drive car-
rier indicates drive activity. A connection to the SATA backplane enables this LED
to blink on and off when that particular drive is being accessed.
Red: The red LED indicates two states. When blinking, it indicates the drive
is rebuilding. When solid, it indicates a drive failure. If a SATA drive fails, you
should be notifi ed by your system management software. Please refer to Chapter
6 for instructions on replacing failed SATA drives.