Supero AS-1010S-T User Manual

®
SUPER
AS1010S-T
USER’S MANUAL
1.0b
The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccuracies that may be contained in this document, makes no commitment to update or to keep current the information in this manual, or to notify any person or organization of the updates. Please Note: For the most up-to-date version of this
manual, please see our web site at www.supermicro.com.
SUPER MICRO COMPUTER reserves the right to make changes to the product described in this manual at any time and without notice. This product, including software, if any, and documenta­tion may not, in whole or in part, be copied, photocopied, reproduced, translated or reduced to any medium or machine without prior written consent.
IN NO EVENT WILL SUPER MICRO COMPUTER BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL, SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO USE THIS PRODUCT OR DOCUMENTATION, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. IN PARTICULAR, SUPER MICRO COMPUTER SHALL NOT HAVE LIABILITY FOR ANY HARDWARE, SOFTWARE, OR DATA STORED OR USED WITH THE PRODUCT, INCLUDING THE COSTS OF REPAIRING, REPLACING, INTEGRATING, INSTALLING OR RECOVERING SUCH HARDWARE, SOFTWARE, OR DATA.
Any disputes arising between manufacturer and customer shall be governed by the laws of Santa Clara County in the State of California, USA. The State of California, County of Santa Clara shall be the exclusive venue for the resolution of any such disputes. Super Micro's total liability for all claims will not exceed the price paid for the hardware product.
FCC Statement: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the manufacturer’s instruction manual, may cause harmful interference with radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case you will be required to correct the interference at your
own expense.
Manual Revision 1.0b
Release Date: June 1, 2007
Unless you request and receive written permission from the manufacturer, you may not copy any part of this document.
Information in this document is subject to change without notice. Other products and companies referred to herein are trademarks or registered trademarks of their respective companies or mark holders.
Copyright © 2007 All rights reserved.
Printed in the United States of America
Preface
About This Manual
This manual is written for professional system integrators and PC technicians. It
provides information for the installation and use of the AS1010S-T server. Installa-
tion and maintainance should be performed by experienced technicians only.
The AS1010S-T is a high-end server based on the SC811FT-260 1U rackmount
chassis and the H8SSL-i, a single processor motherboard that supports AMD Op-
teron processors and up to 4 GB of unbuffered ECC DDR400/333 SDRAM.
Preface
Manual Organization
Chapter 1: Introduction
The fi rst chapter provides a checklist of the main components included with the
server system and describes the main features of the H8SSL-i motherboard and
the SC811FT-260 chassis, which comprise the 1010S-T.
Chapter 2: Server Installation
This chapter describes the steps necessary to install the 1010S-T into a rack and
check out the server confi guration prior to powering up the system. If your server
was ordered without processor and memory components, this chapter will refer you
to the appropriate sections of the manual for their installation.
Chapter 3: System Interface
Refer here for details on the system interface, which includes the functions and
information provided by the control panel on the chassis as well as other LEDs
located throughout the system.
iii
AS1010S-T User's Manual
Chapter 4: System Safety
You should thoroughly familiarize yourself with this chapter for a general overview
of safety precautions that should be followed when installing and servicing the
1010S-T.
Chapter 5: Advanced Motherboard Setup
Chapter 5 provides detailed information on the H8SSL-i motherboard, including the
locations and functions of connections, headers and jumpers. Refer to this chapter
when adding or removing processors or main memory and when reconfi guring the
motherboard.
Chapter 6: Advanced Chassis Setup
Refer to Chapter 6 for detailed information on the SC811FT-260 server chassis.
You should follow the procedures given in this chapter when installing, removing
or reconfi guring SATA or peripheral drives and when replacing the system power
supply and cooling fan.
Chapter 7: BIOS
The BIOS chapter includes an introduction to BIOS and provides detailed informa-
tion on running the CMOS Setup Utility.
Appendix A: BIOS Error Beep Codes
Appendix B: BIOS POST Checkpoint Codes
Appendix C: System Specifi cations
iv
Notes
Preface
v
AS1010S-T User's Manual
Table of Contents
Preface
About This Manual ...................................................................................................... iii
Manual Organization ................................................................................................... iii
Chapter 1: Introduction
1-1 Overview ......................................................................................................... 1-1
1-2 Motherboard Features .................................................................................... 1-2
1-3 Server Chassis Features ................................................................................ 1-5
1-4 Contacting Super Micro .................................................................................. 1-5
Chapter 2: Server Installation
2-1 Overview .......................................................................................................... 2-1
2-2 Unpacking the System ................................................................................... 2-1
2-3 Preparing for Setup ......................................................................................... 2-1
2-4 Installing the System into a Rack .................................................................... 2-4
2-5 Checking the Motherboard Setup .................................................................... 2-8
2-6 Checking the Drive Bay Setup ...................................................................... 2-10
Chapter 3: System Interface
3-1 Overview ......................................................................................................... 3-1
3-2 Control Panel Buttons .................................................................................... 3-1
Reset ....................................................................................................... 3-1
Power ...................................................................................................... 3-1
3-3 Control Panel LEDs ........................................................................................ 3-2
Overheat/Fan Fail .................................................................................. 3-2
NIC2 ........................................................................................................ 3-2
NIC1 ........................................................................................................ 3-3
HDD ........................................................................................................ 3-3
Power ...................................................................................................... 3-3
3-4 Serial ATA Drive Carrier LED ......................................................................... 3-3
Chapter 4: System Safety
4-1 Electrical Safety Precautions ............................................................................ 4-1
4-2 General Safety Precautions .............................................................................. 4-2
4-3 ESD Precautions ............................................................................................. 4-3
4-4 Operating Precautions ..................................................................................... 4-4
vi
Table of Contents
Chapter 5: Advanced Motherboard Setup
5-1 Handling the Motherboard ............................................................................... 5-1
5-2 Mounting the Motherboard into a Chassis ...................................................... 5-2
5-3 Processor and Heatsink Installation ................................................................ 5-2
5-4 Connecting Cables .......................................................................................... 5-5
Connecting Data Cables ........................................................................... 5-5
Connecting Power Cables ......................................................................... 5-5
Connecting the Control Panel ................................................................... 5-6
5-5 I/O Ports ......................................................................................................... 5-7
5-6 Installing Memory ............................................................................................. 5-7
5-7 Adding PCI Cards ............................................................................................ 5-9
5-8 Motherboard Details ..................................................................................... 5-10
H8SSL-i Layout ....................................................................................... 5-10
H8SSL-i Quick Reference ....................................................................... 5-11
5-9 Connector Defi nitions .................................................................................... 5-11
Primary ATX Power Connector ............................................................. 5-12
Secondary Power Connector .................................................................. 5-12
NMI Button ............................................................................................ 5-12
Power LED .............................................................................................. 5-12
HDD LED .............................................................................................. 5-13
NIC1/NIC2 LED ...................................................................................... 5-13
Overheat/Fan Fail LED .......................................................................... 5-13
Power Fail LED ...................................................................................... 5-13
Reset Button ......................................................................................... 5-14
Power Button ......................................................................................... 5-14
Universal Serial Bus (USB0/1) ................................................................ 5-14
Serial ATA Activity LEDs ......................................................................... 5-14
USB2/3 Headers .................................................................................... 5-15
Serial Ports .............................................................................................. 5-15
Fan Headers ............................................................................................ 5-15
Overheat LED .......................................................................................... 5-15
Power LED/Speaker ............................................................................... 5-16
ATX PS/2 Keyboard and Mouse Ports .................................................... 5-16
Wake-On-Ring .......................................................................................... 5-16
Wake-On-LAN ........................................................................................ 5-16
LAN 1/2 (Ethernet Ports) ....................................................................... 5-17
Chassis Intrusion .................................................................................... 5-17
IPMI Header ........................................................................................... 5-17
Power Supply Fail Alarm Header ........................................................... 5-17
vii
AS1010S-T User's Manual
Power Supply Fail Alarm Reset Header ................................................. 5-17
5-10 Jumper Settings ............................................................................................. 5-18
Explanation of Jumpers ........................................................................... 5-18
CMOS Clear ............................................................................................ 5-18
Onboard Speaker Enable/Disable ......................................................... 5-19
PCI-X Slot Speed ................................................................................... 5-19
VGA Enable/Disable ................................................................................ 5-19
LAN Enable/Disable ............................................................................... 5-19
Watch Dog Enable/Disable ..................................................................... 5-20
Power Force On Enable/Disable ............................................................. 5-20
SMBus Enable/Disable ............................................................................ 5-20
5-11 Onboard Indicators ........................................................................................ 5-21
LAN1/LAN2 LEDs .................................................................................... 5-21
SATA Activity LEDs ................................................................................ 5-21
5-12 Floppy, IDE and SATA Drive Connections ..................................................... 5-22
Floppy Connector .................................................................................... 5-22
IDE Connector ........................................................................................ 5-23
SATA Connectors .................................................................................... 5-23
5-13 Enabling SATA RAID ..................................................................................... 5-24
Chapter 6: Advanced Chassis Setup
6-1 Static-Sensitive Devices .................................................................................. 6-1
6-2 Control Panel .................................................................................................... 6-2
6-3 System Fans ..................................................................................................... 6-3
System Fan Failure .................................................................................... 6-3
Replacing System Fans ............................................................................. 6-3
6-4 Drive Bay Installation/Removal ......................................................................... 6-4
SATA Drive Installation ............................................................................. 6-4
CD-ROM and Floppy Drive Installation .................................................... 6-6
6-5 Power Supply .................................................................................................. 6-7
Power Supply Failure ................................................................................. 6-7
Replacing the Power Supply ...................................................................... 6-7
Chapter 7: BIOS
7-1 Introduction ....................................................................................................... 7-1
7-2 Main Menu ....................................................................................................... 7-2
7-3 Advanced Settings Menu ................................................................................ 7-2
7-4 Boot Menu ..................................................................................................... 7-12
7-5 Security .......................................................................................................... 7-14
viii
Appendices:
Appendix A: BIOS Error Beep Codes
Appendix B: BIOS POST Checkpoint Codes
Appendix C: System Specifi cations
Table of Contents
ix
AS1010S-T User's Manual
Notes
x
Chapter 1: Introduction
Chapter 1
Introduction
1-1 Overview
The AS1010S-T is a single processor, mini 1U rackmount server comprised of two
main subsystems: the SC811FT-260 chassis and the H8SSL-i motherboard. The
H8SSL-i supports a single AMD Opteron 100 series processor in a 939-pin socket
and up to 4 GB of unbuffered DDR400/333 SDRAM memory. Please refer to our
web site for information on operating systems that have been certifi ed for use with
the 1010S-T and for regular updates on supported processor speeds.
In addition to the motherboard and chassis, various hardware components may
have been included with the 1010S-T, as listed below.
One (1) slim fl oppy drive [FPD-PNSC-02(01)]
One (1) slim CD-ROM drive [CDM-TEAC-24(B)]
Two (2) hot-swap SATA drive carriers [(CSE-PT10-(B)]
Two (2) SATA cables (CBL-0044)
One (1) SATA LED cable (CBL-0056)
One (1) air shroud (CSE-PT0113)
Two (2) 4-cm counter-rotating fans (FAN-0087)
One (1) SATA backplane (CSE-SATA-810)
One (1) CPU backplate (BKT-0004)
One (1) heatsink retention module with two (2) screws (BKT-0005)
One (1) PCI-X slot riser card (CSE-RR1U-X)
Rackmount hardware with screws (CSE-PT8)
Two (2) rack rail assemblies
Six (6) brackets for mounting the rack rails in a rack/telco rack
One (1) CD containing drivers and utilities
1-1
AS1010S-T User's Manual
1-2 Motherboard Features
At the heart of the 1010S-T lies the H8SSL-i, a single processor motherboard
designed to provide maximum performance. Below are the main features of
the H8SSL-i. (See Figure 1-1 for a block diagram of the ServerWorks HT-1000
chipset.)
Processors
The H8SSL-i has an 939-pin ZIF socket that supports a single AMD Opteron Series
100 processor. Please refer to the support section of our web site for a complete
listing of supported processors.
Memory
The H8SSL-i has four (4) 184-pin DIMM sockets that can support up to 4 GB of
unbuffered ECC DDR400/333 SDRAM. (Memory can operate in either single or
dual-channel mode.) Low-profi le memory modules are required for use in the 1U
form factor of the 1010S-T.
Serial ATA
A Serial ATA controller is incorporated into the ServerWorks HT-1000 chipset. The
Serial ATA drives in the 1010S-T are hot-swappable.
PCI Expansion Slots
The H8SSL-i has one 64-bit, 133 MHz (3.3V) PCI-X slot and two 32-bit, 33 MHz
(5V) PCI slots. When incorporated into the 1010S-T server system, a riser card
(CSE-RR1U-X) is included for use with the PCI-X slot to support one standard (full-
height, full-length) expansion card in the 133 MHz PCI-X slot.
Ethernet Ports
A Broadcom BCM5704 Ethernet controller is incorporated into the H8SSL-i to sup-
port two Gigabit LAN ports.
1-2
Chapter 1: Introduction
ATI G raphics Controller
An ATI video controller based on the Rage XL 8 MB graphics chip is integrated
onboard the H8SSL-i.
Onboard Controllers/Ports
An onboard IDE controller supports one fl oppy drive and up to two Ultra ATA 100
hard drives or ATAPI devices. Onboard I/O backpanel ports include one serial
COM port, two USB ports, a VGA (monitor) port, PS/2 mouse and keyboard ports
and two GLAN (RJ45) ports.
Other Features
Other onboard features that promote system health include voltage monitors, a
chassis intrusion header, auto-switching voltage regulators, chassis and CPU
overheat sensors, virus protection and BIOS rescue.
1-3
AS1010S-T User's Manual
Figure 1-1 . ServerWorks HT-1000 Chipset:
System Block Diagram
Note: This is a general block diagram. Please see Chapter 5 for details.
184-pin DIMMs
AMD Opteron Processor
TM
33 MHz PCI Slots (2)
Rage XL
USB 2.0
UDMA100
8x H T @ 1 .6 GB/ sec
33 MHz Bus
Floppy Disk Drive
Serial Ports
ServerWorks
HT-1000
LPC Link
NS87427
Super I/O
144 -bi t, 200 -400 MT /s
GLAN (2 )
133 MHz Bus
SATA
BIOS
PS/2 Kybd/Mouse
Ports (4)
PCI -X 133 MH z Slot
1-4
Chapter 1: Introduction
1-3 Server Chassis Features
The 1010S-T is a mini 1U rackmount server platform confi guration. The following
is a general outline of the main features of the SC811FT-260 chassis.
System Power
When confi gured as a 1010S-T, the SC811FT-260 chassis includes a single 260W
power supply.
Control Panel
The SC811FT-260's control panel provides important system monitoring and control
information. LEDs indicate power on, network activity, hard disk drive activity and
overheat/fan fail conditions. The control panel also includes a main power button
and a system reset button.
Rear I/O Panel
The SC811FT-260 is a 1U rackmount chassis. Its I/O panel provides one expan-
sion card slot, one COM port, two USB ports, PS/2 mouse and keyboard ports, a
graphics port and two Gb Ethernet ports. (See Chapter 6 for details.)
Cooling System
The SC811FT-260 chassis has an innovative cooling design that features two 4-
cm heavy-duty, counter-rotating fans. A fan speed control setting in BIOS allows
fan speed to be determined by system temperature [the recommended setting is
3-pin (Server)].
1-5
AS1010S-T User's Manual
1-4 Contacting Super Micro
Headquarters
Address: Super Micro Computer, Inc. 980 Rock Ave. San Jose, CA 95131 U.S.A. Tel: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: marketing@supermicro.com (General Information) support@supermicro.com (Technical Support) Web Site: www.supermicro.com
Europe
Address: Super Micro Computer B.V. Het Sterrenbeeld 28, 5215 ML 's-Hertogenbosch, The Netherlands Tel: +31 (0) 73-6400390 Fax: +31 (0) 73-6416525 Email: sales@supermicro.nl (General Information) support@supermicro.nl (Technical Support) rma@supermicro.nl (Customer Support)
Asia-Pacifi c
Address: Super Micro, Taiwan 4F, No. 232-1, Liancheng Rd. Chung-Ho 235, Taipei, Taiwan, R.O.C. Tel: +886-(2) 8226-3990 Fax: +886-(2) 8226-3991 Web Site: www.supermicro.com.tw Technical Support: Email: support@supermicro.com.tw Tel: 886-2-8228-1366, ext.132 or 139
1-6
Chapter 2: Server Installation
Chapter 2
Server Installation
2-1 Overview
This chapter provides a quick setup checklist to get your 1010S-T up and run-
ning. Following the steps in the order given should enable you to have the system
operational within a minimal amount of time. This quick setup assumes that your
1010S-T system has come to you with the processor and memory preinstalled. If
your system is not already fully integrated with a motherboard, processor, system
memory etc., please turn to the chapter or section noted in each step for details
on installing specifi c components.
2-2 Unpacking the System
You should inspect the box the 1010S-T was shipped in and note if it was damaged
in any way. If the server itself shows damage, you should fi le a damage claim with
the carrier who delivered it.
Decide on a suitable location for the rack unit that will hold the 1010S-T. It should
be situated in a clean, dust-free area that is well ventilated. Avoid areas where
heat, electrical noise and electromagnetic fi elds are generated. You will also need
it placed near a grounded power outlet. Read the Rack and Server Precautions in
the next section.
2-3 Preparing for Setup
The box the 1010S-T was shipped in should include two sets of rail assemblies,
two rail mounting brackets and the mounting screws you will need to install the
system into the rack. Follow the steps in the order given to complete the installation
process in a minimal amount of time. Please read this section in its entirety before
you begin the installation procedure outlined in the sections that follow.
2-1
AS1010S-T User's Manual
Choosing a Setup Location
- Leave enough clearance in front of the rack to enable you to open the front door
completely (~25 inches).
- Leave approximately 30 inches of clearance in the back of the rack to allow for
suffi cient airfl ow and ease in servicing.
- This product is for installation only in a Restricted Access Location (dedicated
equipment rooms, service closets, etc.).
- This product is not suitable for use with visual display work place devices according
to §2 of the the German Ordinance for Work with Visual Display Units.
!
Warnings and Precautions!
!
Rack Precautions
- Ensure that the leveling jacks on the bottom of the rack are fully extended to the
fl oor with the full weight of the rack resting on them.
- In a single rack installation, stabilizers should be attached to the rack.
- In multiple rack installations, the racks should be coupled together.
- Always make sure the rack is stable before extending a component from the
rack.
- You should extend only one component at a time - extending two or more simul-
taneously may cause the rack to become unstable.
Server Precautions
- Review the electrical and general safety precautions in Chapter 4.
- Determine the placement of each component in the rack before you install the
rails.
- Install the heaviest server components on the bottom of the rack fi rst, and then
work up.
- Use a regulating uninterruptible power supply (UPS) to protect the server from
power surges, voltage spikes and to keep your system operating in case of a power
failure.
-
Allow the power supply units and hot plug Serial ATA drives to cool before touching
them.
- Always keep the rack's front door and all panels and components on the servers
closed when not servicing to maintain proper cooling.
2-2
Chapter 2: Server Installation
Rack Mounting Considerations
Ambient Operating Temperature
If installed in a closed or multi-unit rack assembly, the ambient operating tempera-
ture of the rack environment may be greater than the ambient temperature of the
room. Therefore, consideration should be given to installing the equipment in an
environment compatible with the manufacturer’s maximum rated ambient tempera-
ture (Tmra).
Reduced Airfl ow
Equipment should be mounted into a rack so that the amount of airfl ow required
for safe operation is not compromised.
Mechanical Loading
Equipment should be mounted into a rack so that a hazardous condition does not
arise due to uneven mechanical loading.
Circuit Overloading
Consideration should be given to the connection of the equipment to the power
supply circuitry and the effect that any possible overloading of circuits might have
on overcurrent protection and power supply wiring. Appropriate consideration of
equipment nameplate ratings should be used when addressing this concern.
Reliable Ground
A reliable ground must be maintained at all times. To ensure this, the rack itself
should be grounded. Particular attention should be given to power supply connec-
tions other than the direct connections to the branch circuit (i.e. the use of power
strips, etc.).
2-3
AS1010S-T User's Manual
2-4 Installing the System into a Rack
This section provides information on installing the 1010S-T into a rack unit. If the
system has already been mounted into a rack, you can skip ahead to Sections 2-5
and 2-6. There are a variety of rack units on the market, which may mean the as-
sembly procedure will differ slightly. The following is a guideline for installing the
unit into a rack with the rack rails provided with the system. You should also refer
to the installation instructions that came with the rack unit you are using.
Identifying the Sections of the Rack Rails
You should have received two rack rail assemblies with the 1010S-T. Each of these
assemblies consist of two sections: an inner fi xed chassis rail that secures to the
unit (A) and an outer fi xed rack rail (B) that secures to the rail brackets. A sliding
rail guide sandwiched between the two should remain attached to the fi xed rack rail
(see Figure 2-1). The A and B rails must be detached from each other to install.
To remove the fi xed chassis rail (A), pull it out as far as possible - you should hear
a "click" sound as a locking tab emerges from inside the rail assembly and locks
the inner rail. Then depress the locking tab to pull the inner rail completely out.
Do this for both the left and right side rack rail assemblies.
Figure 2-1. Identifying the Sections of the Rack Rails
Outer rail (to be installed in the rack)
Pull out the inner rail(to be attached on the chassis)
B
A
2-4
Chapter 2: Server Installation
Installing the Chassis Rails
Position the fixed chassis rail sections you just removed along the side of the chassis making sure the fi ve screw holes line up. Note that these two rails
are left/right specifi c. Screw the rail securely to the side of the chassis (see Figure
2-2). Repeat this procedure for the other rail on the other side of the chassis. You
will also need to attach the rail brackets when installing into a telco rack.
Locking Tabs: As you have seen, both chassis rails have a locking tab, which
serves two functions. The fi rst is to lock the server into place when installed and
pushed fully into the rack, which is its normal position. Secondly, these tabs also
lock the server in place when fully extended from the rack. This prevents the server
from coming completely out of the rack when you pull it out for servicing.
Figure 2-2. Installing Chassis Rails
Installing the Rack Rails
Determine where you want to place the 1010S-T in the rack (see Rack and Server
Precautions in Section 2-3). Position the fi xed rack rail/sliding rail guide assemblies
at the desired location in the rack, keeping the sliding rail guide facing the inside
of the rack. Screw the assembly securely to the rack using the brackets provided.
Attach the other assembly to the other side of the rack, making sure that both are
at the exact same height and with the rail guides facing inward.
2-5
AS1010S-T User's Manual
Installing the Server into the Rack
You should now have rails attached to both the chassis and the rack unit. The next
step is to install the server into the rack. Do this by lining up the rear of the chas-
sis rails with the front of the rack rails. Slide the chassis rails into the rack rails,
keeping the pressure even on both sides (you may have to depress the locking
tabs when inserting). See Figure 2-3.
When the server has been pushed completely into the rack, you should hear the
locking tabs "click".
Figure 2-3. Installing the Server into a Rack
2-6
Chapter 2: Server Installation
Installing the Server into a Telco Rack
If you are installing the 1010S-T into a Telco type rack, follow the directions given
on the previous pages for rack installation. The only difference in the installation
procedure will be the positioning of the rack brackets to the rack. They should be
spaced apart just enough to accomodate the width of the telco rack.
Figure 2-4. Installing the Server into a Telco Rack
2-7
AS1010S-T User's Manual
2-5 Checking the Motherboard Setup
After you install the 1010S-T in the rack, you will need to open the unit to make sure
the motherboard is properly installed and all the connections have been made.
1. Accessing the inside of the system (Figure 2-5)
First, grasp the two handles on either side and pull the unit straight out until it locks
(you will hear a "click"). Next, depress the two buttons on the top of the chassis to
release the top cover. There is a large rectangular recess in the middle front of the
top cover to help you push the cover away from you until it stops. You can then lift
the top cover from the chassis to gain full access to the inside of the server.
2. Check the CPU (processor)
You may have a processor already installed to the system board. The processor
should have a heatsink attached. See Chapter 5 for instructions on processor and
heatsink installation.
3. Check the system memory
Your 1010S-T server system may have come with system memory already installed.
Make sure all DIMMs are fully seated in their slots. For details on adding system
memory, refer to Chapter 5.
4. Installing add-on cards
If desired, you can install an add-on card to the system. See Chapter 5 for details
on installing a PCI add-on card.
5. Check all cable connections and airfl ow
Make sure all power and data cables are properly connected and not blocking the
airfl ow. See Chapter 5 for details on cable connections. Also, check the air seals
for damage. The air seals are located under the blower fan and beneath the frame
cross section that separates the drive bay area from the motherboard area of the
chassis.
2-8
Chapter 2: Server Installation
Figure 2-5. Accessing the Inside of the System
2-9
AS1010S-T User's Manual
2-6 Checking the Drive Bay Setup
Next, you should check to make sure the peripheral drives and the Serial ATA drives
and Serial ATA backplane have been properly installed and all essential connec-
tions have been made.
1. Accessing the drive bays
All drives can be accessed from the front of the server. For servicing the CD-ROM
and fl oppy drives, you will need to remove the top chassis cover. The Serial ATA
disk drives can be installed and removed from the front of the chassis without
removing the top chassis cover.
2. Installing a CD-ROM and fl oppy disk drives
Refer to Chapter 6 if you need to reinstall a CD-ROM and/or fl oppy disk drive to
the system.
3. Check the Serial ATA disk drives
Depending upon your system's confi guration, your system may have one or two
Serial ATA drives already installed. If you need to install Serial ATA drives, please
refer to the appropriate section in Chapter 6.
4. Check the airfl ow
Airfl ow is provided by two 4-cm counter-rotating fans. The system component layout
was carefully designed to promote suffi cient airfl ow through the small 1U rackmount
space. Also note that all power and data cables have been routed in such a way
that they do not block the airfl ow generated by the fans.
5. Supplying power to the system
The last thing you must do is to provide input power to the system. Plug the power
cord from the power supply unit into a high-quality power strip that offers protec-
tion from electrical noise and power surges. It is recommended that you use an
uninterruptible power supply (UPS).
2-10
Chapter 3: System Interface
Chapter 3
System Interface
3-1 Overview
There are several LEDs on the control panel as well as others on the Serial ATA
drive carriers to keep you constantly informed of the overall status of the system
as well as the activity and health of specifi c components. There are also two but-
tons on the chassis control panel. This chapter explains the meanings of all LED
indicators and the appropriate response you may need to take.
3-2 Control Panel Buttons
There are two push-button buttons located on the front of the chassis. These are
(in order from left to right) a reset button and a power on/off button.
RESET:
POWER: This is the main power switch, which is used to apply or turn off
the main system power. Turning off system power with this button removes the
main power but keeps standby power supplied to the system.
The reset switch reboots the system.
3-1
AS1010S-T User's Manual
3-3 Control Panel LEDs
The control panel located on the front of the chassis has fi ve LEDs. These LEDs
provide you with critical information related to different parts of the system. This
section explains what each LED indicates when illuminated and any corrective ac-
tion you may need to take.
Overheat/Fan Fail: When this LED fl ashes, it indicates a fan failure. When
on continuously it indicates an overheat condition, which may be caused by cables
obstructing the airfl ow in the system or the ambient room temperature being too
warm. Check the routing of the cables and make sure all fans are present and
operating normally. You should also check to make sure that the chassis covers
are installed. Finally, verify that the heatsinks are installed properly (see Chapter
5). This LED will remain fl ashing or on as long as the indicated condition exists.
2
NIC2: Indicates network activity on JLAN2 when fl ashing .
1
NIC1: Indicates network activity on JLAN1 when fl ashing.
HDD: Channel activity for all HDDs. This light indicates CD-ROM and SATA
drive activity when fl ashing.
3-2
Chapter 3: System Interface
Power: Indicates power is being supplied to the system's power supply units.
This LED should normally be illuminated when the system is operating.
3-4 Serial ATA Drive Carrier LED
Each Serial ATA drive carrier has a green LED. When illuminated, this green LED
(on the front of the Serial ATA drive carrier) indicates drive activity.
3-3
AS1010S-T User's Manual
Notes
3-4
Loading...
+ 70 hidden pages