Supero 6016T-6RFT, SUPERSERVER 6016T-6RFT+, SUPERSERVER 6016T-6RF+ User Manual

SUPERSERVER 6016T-6RFT+
SUPERSERVER 6016T-6RF+
SUPER
®
USER’S MANUAL
1.0
manual, please see our web site at www.supermicro.com.
Super Micro Computer, Inc. ("Supermicro") reserves the right to make changes to the product described in this manual at any time and without notice. This product, including software and docu­mentation, is the property of Supermicro and/or its licensors, and is supplied only under a license. Any use or reproduction of this product is not allowed, except as expressly permitted by the terms of said license.
IN NO EVENT WILL SUPERMICRO BE LIABLE FOR DIRECT, INDIRECT , SPECIAL, INCIDENTAL, SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO USE THIS PRODUCT OR DOCUMENTATION, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. IN PARTICULAR, SUPERMICRO SHALL NOT HAVE LIABILITY FOR ANY HARDWARE, SOFTW ARE, OR DA TA STORED OR USED WITH THE PRODUCT, INCLUDING THE COSTS OF REPAIRING, REPLACING, INTEGRATING, INSTALLING OR RECOVERING SUCH HARDWARE, SOFTWARE, OR DATA.
Any disputes arising between manufacturer and customer shall be governed by the laws of Santa Clara County in the State of California, USA. The State of California, County of Santa Clara shall be the exclusive venue for the resolution of any such disputes. Super Micro's total liability for all claims will not exceed the price paid for the hardware product.
FCC Statement: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environ­ment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the manufacturer’s instruction manual, may cause harmful interference with radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case you will be required to correct the interference at your own expense.
California Best Management Practices Regulations for Perchlorate Materials: This Perchlorate warn­ing applies only to products containing CR (Manganese Dioxide) Lithium coin cells. “Perchlorate Material-special handling may apply. See www.dtsc.ca.gov/hazardouswaste/perchlorate”
WARNING: Handling of lead solder materials used in this product may expose you to lead, a chemical known to the State of California to cause birth defects and other repro­ductive harm.
Manual Revision 1.0 Release Date: August 4, 2010
Unless you request and receive written permission from Super Micro Computer, Inc., you may not copy any part of this document.
Information in this document is subject to change without notice. Other products and companies referred to herein are trademarks or registered trademarks of their respective companies or mark holders.
Copyright © 2010 by Super Micro Computer, Inc. All rights reserved.
Printed in the United States of America
iii
Preface
Preface
About This Manual
This manual is written for professional system integrators and PC technicians. It provides information for the installation and use of the SuperServer 6016T­6RFT+/6016T-6RF+. Installation and maintenance should be performed by expe­rienced technicians only.
Manual Organization
Chapter 1: Introduction
The fi rst chapter provides a checklist of the main components included with the server system and describes the main features of the X8DTU-6TF+/X8DTU-6F+ serverboard and the SC819TQ-R700U chassis, which comprise the SuperServer 6016T-6RFT+/6016T-6RF+.
Chapter 2: Server Installation
This chapter describes the steps necessary to install the SuperServer into a rack and check out the server confi guration prior to powering up the system. If your server was ordered without processor and memory components, this chapter will refer you to the appropriate sections of the manual for their installation.
Chapter 3: System Interface
Refer here for details on the system interface, which includes the functions and information provided by the control panel on the chassis as well as other LEDs located throughout the system.
Chapter 4: System Safety
You should thoroughly familiarize yourself with this chapter for a general overview of safety precautions that should be followed when installing and servicing the SuperServer 6016T-6RFT+/6016T-6RF+.
SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's Manual
iv
Chapter 5: Advanced Serverboard Setup
Chapter 5 provides detailed information on the X8DTU-6TF+/X8DTU-6F+ serverboard, including the locations and functions of connections, headers and jumpers. Refer to this chapter when adding or removing processors or main memory and when reconfi guring the serverboard.
Chapter 6: Advanced Chassis Setup
Refer to Chapter 6 for detailed information on the SC819TQ-R700U server chassis. You should follow the procedures given in this chapter when installing, removing or reconfi guring SATA or peripheral drives and when replacing system power supply modules and cooling fans.
Chapter 7: BIOS
The BIOS chapter includes an introduction to BIOS and provides detailed informa­tion on running the CMOS Setup Utility.
Appendix A: BIOS Error Beep Codes
Appendix B: System Specifi cations
v
Preface
Notes
vi
SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's Manual
Table of Contents
Chapter 1 Introduction
1-1 Overview .........................................................................................................1-1
1-2 Serverboard Features .....................................................................................1-2
Processors ......................................................................................................1-2
Memory ...........................................................................................................1-2
UIO ..................................................................................................................1-2
Onboard SAS .................................................................................................. 1-2
Onboard Serial ATA ........................................................................................1-2
Rear I/O Ports ................................................................................................. 1-3
Graphics Controller ......................................................................................... 1-3
Other Features ................................................................................................ 1-3
1-3 Server Chassis Features ................................................................................1-3
System Power ................................................................................................. 1-3
Hard Drives ..................................................................................................... 1-3
PCI Expansion Slots ....................................................................................... 1-4
Front Control Panel .........................................................................................1-4
Cooling System ............................................................................................... 1-4
1-4 Contacting Supermicro ....................................................................................1-6
Chapter 2 Server Installation
2-1 Overview .........................................................................................................2-1
2-2 Unpacking the System .................................................................................... 2-1
2-3 Preparing for Setup .........................................................................................2-1
Choosing a Setup Location ............................................................................. 2-1
Rack Precautions ............................................................................................ 2-2
Server Precautions .......................................................................................... 2-2
Rack Mounting Considerations .......................................................................2-3
Ambient Operating Temperature ................................................................2-3
Reduced Airfl ow .........................................................................................2-3
Mechanical Loading ...................................................................................2-3
Circuit Overloading .....................................................................................2-3
Reliable Ground .........................................................................................2-3
2-4 Installing the System into a Rack ................................................................... 2-4
Identifying the Sections of the Rack Rails ...................................................... 2-4
Installing the Inner Rails .................................................................................2-4
Installing the Outer Rails ................................................................................. 2-5
Installing the Server into a Telco Rack ...........................................................2-6
vii
Table of Contents
2-5 Checking the Serverboard Setup .................................................................... 2-8
Chapter 3 System Interface
3-1 Overview .........................................................................................................3-1
3-2 Control Panel Buttons ..................................................................................... 3-1
UID ..................................................................................................................3-1
Reset ...............................................................................................................3-1
Power ..............................................................................................................3-1
3-3 Control Panel LEDs ........................................................................................3-2
UID/Overheat/Fan Fail/Power Fail .................................................................. 3-2
NIC2 ................................................................................................................3-2
NIC1 ................................................................................................................3-2
HDD .................................................................................................................3-2
Power ..............................................................................................................3-3
3-4 Drive Carrier LEDs ..........................................................................................3-3
Chapter 4 System Safety
4-1 Electrical Safety Precautions .......................................................................... 4-1
4-2 General Safety Precautions ............................................................................4-2
4-3 ESD Precautions ............................................................................................. 4-3
4-4 Operating Precautions .................................................................................... 4-4
Chapter 5 Advanced Serverboard Setup
5-1 Handling the Serverboard ............................................................................... 5-1
Precautions .....................................................................................................5-1
Unpacking .......................................................................................................5-1
5-2 Processor and Heatsink Installation................................................................5-2
Installing LGA1366 Processors ....................................................................... 5-2
Installing the Heatsink .....................................................................................5-4
Removing the Heatsink ................................................................................... 5-5
5-3 Connecting Cables .......................................................................................... 5-6
Connecting Data Cables ................................................................................. 5-6
Connecting Power Cables ..............................................................................5-6
Connecting the Control Panel ......................................................................... 5-6
5-4 I/O Ports ..........................................................................................................5-7
5-5 Installing Memory ............................................................................................ 5-8
5-6 Adding PCI Cards ......................................................................................... 5-12
5-7 Serverboard Details ...................................................................................... 5-13
X8DTU-6TF+/X8DTU-6F+ Quick Reference ................................................. 5-14
5-8 Connector Defi nitions .................................................................................... 5-15
5-9 Jumper Settings ............................................................................................5-23
viii
SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's Manual
5-10 Onboard Indicators ........................................................................................5-25
5-11 SATA Port Connections .................................................................................5-27
5-12 Installing Software ......................................................................................... 5-28
Supero Doctor III ...........................................................................................5-29
Chapter 6 Advanced Chassis Setup
6-1 Static-Sensitive Devices ..................................................................................6-1
Precautions .....................................................................................................6-1
6-2 Control Panel ..................................................................................................6-2
6-3 System Fans ...................................................................................................6-3
System Fan Failure .........................................................................................6-3
Hard Drive Installation ..................................................................................... 6-5
Hard Drive Backplane ..................................................................................... 6-6
DVD-ROM Drive Installation ........................................................................... 6-7
6-4 Power Supply .................................................................................................. 6-8
Power Supply Failure ......................................................................................6-8
Chapter 7 BIOS
7-1 Introduction ......................................................................................................7-1
Starting BIOS Setup Utility .............................................................................. 7-1
How To Change the Confi guration Data ......................................................... 7-1
Starting the Setup Utility ................................................................................. 7-2
7-2 Main Setup ...................................................................................................... 7-2
7-3 Advanced Setup Confi gurations......................................................................7-4
7-4 Security Settings ...........................................................................................7-25
7-5 Boot Confi guration ........................................................................................ 7-27
7-6 Exit Options ................................................................................................... 7-28
Appendix A BIOS Error Beep Codes Appendix B System Specifi cations
Chapter 1
Introduction
1-1 Overview
The SuperServer 6016T-6RFT+/6016T-6RF+ is a high-end server comprised of two main subsystems: the SC819TQ-R700U 1U server chassis and the X8DTU-6TF+/ X8DTU-6F+ dual processor serverboard. Please refer to our web site for informa­tion on operating systems that have been certifi ed for use with the system (www. supermicro.com).
In addition to the serverboard and chassis, various hardware components have been included with the 6016T-6RFT+/6016T-6RF+, as listed below:
One slim DVD-ROM drive (DVM-TEAC-DVD-SBT)
Five sets of 4-cm counter-rotating fans (FAN-0086L4)
One air shroud (MCP-310-81901-0B)
Two passive CPU heatsinks (SNK-P0037P)
Riser Cards: (see Section 5-6 for details) One RSC-R1UU-2E8 One RSC-R1UU-E8R+
SATA Accessories One SATA backplane (BPN-SAS-815TQ) One SAS cable (CBL-0288L) Four SATA drive carriers (MCP-220-00075-0B)
One rackmount kit (MCP-290-00062-0N)
One CD containing drivers and utilities
SuperServer 6016T-6RFT+/6016T-6RF+ User's Manual
Chapter 1: Introduction
1-1
1-2
SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's Manual
1-2 Serverboard Features
At the heart of the SuperServer 6016T-6RFT+/6016T-6RF+ lies the X8DTU-6TF+/ X8DTU-6F+, a dual processor serverboard based on the Intel® 5520 chipset. Below are the main features of the serverboard. (See Figure 1-1 for a block diagram of the chipset).
Processors
The X8DTU-6TF+/X8DTU-6F+ supports single or dual Intel® 5500/5600 Series processors in LGA1366 sockets. Please refer to our web site for a complete listing of supported processors (www.supermicro.com).
Memory
The X8DTU-6TF+/X8DTU-6F+ features 18 DIMM sockets that can support up to 192 GB of registered ECC DDR3-1333/1066/800 or 48 GB of unbuffered ECC/non-ECC DDR3-1333/1066/800 SDRAM. Please refer to Chapter 5 for installing memory.
UIO
The X8DTU-6TF+/X8DTU-6F+ is a spe cially- designed ser verboa rd that features Super micro's UIO ( Universal I /O) technolog y. UIO ser verboar ds have a PCI Ex­press 2.0 x8 slot that can support any one of several types of UIO card types to add SAS por ts, SATA ports, add itional L AN p ort s or other addi tional f unctio ns to the ser verbo ard. Thi s allow s the use r to tail or the se rve rboa rd to the ir own ne eds.
Note: the ser ver does n ot com e with a UI O card i nstal led.
Onboard SAS
An onboard LSI 2108 SAS controller in integrated into the X8DTU-6TF+/X8DTU­6F+. The hot-swap SAS drives are connected to a backplane that provides power, bus termination and confi guration settings.
Note: The operating system you use must have RAID support to enable the hot-swap capability and RAID function of the SAS drives. RAID 0, 1, 5, 6, 10, 50 and 60 is suppor ted. Refer to the following ftp site for setup guidelines <ftp://ftp.supermicro.com/driver/SAS/LSI/LSI _ SAS_EmbM RAID_ SWUG.pdf >.
Onboard Serial ATA
An on -c hip (IC H10R) SATA controller is i ntegrate d into the X8DTU-6TF+/X8DTU­6F+ to provid e a six-por t, 3 Gb /sec SATA subsystem, whic h is R AID 0, 1, 5 and
1-3
Chapter 1: Introduction
10 suppor ted ( R A ID 5 is s upp or te d wit h Win dows O S onl y). The SATA drives are hot-swappable units.
Note: You must have RAID set up to enable the hot-swap capability of the SATA drives. D ocum entati on on R AI D setup gui deline s can be fo und on our we b site.
Rear I/O Ports
The color-coded I/O ports include one COM port, a VGA (monitor) port, two USB
2.0 ports, PS/2 mouse and keyboard ports, one dedicated IPMI LAN port and two gigabit Ethernet ports. The 6016T-6RFT+ (X8DTU-6TF+) includes two additional Ethernet ports.
Graphics Controller
The X8DTU-6TF+/X8DTU-6F+ features an integrated Matrox G200eW graphics chip.
Other Features
Other onboard features that promote system health include onboard voltage moni­tors, auto-switching voltage regulators, chassis and CPU overheat sensors, virus protection and BIOS rescue.
1-3 Server Chassis Features
The 6016T-6RFT+/6016T-6RF+ is built upon the SC819TQ-R700U chassis. Details on the chassis and on servicing procedures can be found in Chapter 6.The following is a general outline of the main features of the chassis.
System Power
The SC819TQ-R700U features a redundant 700W power supply consisting of two power modules. The system does not need to be shut down when replacing or removing a single power supply module.
Hard Drives
The SC819TQ-R700U chassis was designed to support four hot-swap SAS or SATA hard drives.
1-4
SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's Manual
PCI Expansion Slots
Two riser cards are included. The RSC-R1UU-E8R+ is located on the right side of the chassis and supports one low- profi le PCI- E x4 card (in a x 8 slot). The RSC- R1UU-2E8 is located on the left side of the chassis and supports two PCI- E x8 add- on cards. See our web site for details (http://www.supermicro.com/products/ nfo/UIO.cfm). See section 5-6 of this manual for details.
Front Control Panel
The chassis' control panel provides you with system monitoring and control. LEDs indicate system power, HDD activity, network activity (2), overheat/fan/power failure and UID (Unit Identifi er). A main power button and a UID button is also included.
Cooling System
The SC819TQ-R700U has an innovative cooling design that features fi ve sets of 4-cm counter-rotating fans located in the middle section of the chassis. There is a "Fan Speed Control Mode" setting in BIOS that allows chassis fan speed to be determined by system temperature. The power supply module also includes a cooling fan.
1-5
Chapter 1: Introduction
Figure 1-1. Intel 5520 + IOH-36D/ICH10R Chipset:
System Block Diagram
Note: This is a general block diagram. Please see Chapter 5 for details.
Processor#1
QPI
DDR3 DIMM
C
A
B
D
E
F
DDR3 DIMM
DDR3 DIMM
DDR3 DIMM
DDR3 DIMM
DDR3 DIMM
B
C
E
F
3,4
BMC
VGA SWITCH
ESI
SPI
ATME L AT25DF321
CLINK
CLINK
PCIE Port 1-4
PCI-E x8
Gen2 x16
Gen2 x8
ICH10R
ESI
IOH 36D
PORT0
PORT
PORT 7,8,9,10
5,6
PCI-E x16
PORT
PCI-Ex8
in x4 slot
RJ45
COMA
COMB
SIO
PS2 KB/MS
USB 0/1
USB
QPI
QPI
Gen2 x8
PORT
8,10
(Lane Reversal)
SATA #2 SATA #3 SATA #4 SATA #5
SATA #0
SATA
PCI
USB
TPM
LPC
PORT1 PORT1
Gen2 x4
PORT
1,2
in x16 slot
VGA VGA
KAWELA
RJ45 RJ45
Gen1x2
KAWELA
RJ45 RJ45
Gen1 x4
PCIE Port 5-6
Processor#0
SATA #1
USB 2/3
USB 4/5 USB 6 USB 7
PORT0
1-6
SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's Manual
1-4 Contacting Supermicro
Headquarters
Address: Super Micro Computer, Inc.
980 Rock Ave. San Jose, CA 95131 U.S.A.
Tel: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: marketing@supermicro.com (General Information)
support@supermicro.com (Technical Support)
Web Site: www.supermicro.com
Europe
Address: Super Micro Computer B.V.
Het Sterrenbeeld 28, 5215 ML 's-Hertogenbosch, The Netherlands
Tel: +31 (0) 73-6400390 Fax: +31 (0) 73-6416525 Email: sales@supermicro.nl (General Information)
support@supermicro.nl (Technical Support) rma@supermicro.nl (Customer Support)
Asia-Pacifi c
Address: Super Micro Computer, Inc.
4F, No. 232-1, Liancheng Rd. Chung-Ho 235, Taipei County Taiwan, R.O.C.
Tel: +886-(2) 8226-3990 Fax: +886-(2) 8226-3991 Web Site: www.supermicro.com.tw Technical Support: Email: support@supermicro.com.tw Tel: 886-2-8228-1366, ext.132 or 139
Chapter 2: Server Installation
2-1
Chapter 2
Server Installation
2-1 Overview
This chapter provides a quick setup checklist to get your 6016T-6RFT+/6016T-6RF+ up and running. Following these steps in the order given should enable you to have the system operational within a minimum amount of time. This quick setup assumes that your system has come to you with the processors and memory pre-installed. If your system is not already fully integrated with a serverboard, processors, system memory etc., please turn to the chapter or section noted in each step for details on installing specifi c components.
2-2 Unpacking the System
You should inspect the box the 6016T -6RFT+/6016T-6RF+ was shipped in and note if it was damaged in any way. If the server itself shows damage you should fi le a damage claim with the carrier who delivered it.
Decide on a suitable location for the rack unit that will hold the 6016T-6RFT+/6016T­6RF+. It should be situated in a clean, dust-free area that is well ventilated. Avoid areas where heat, electrical noise and electromagnetic fi elds are generated. You will also need it placed near a grounded power outlet. Be sure to read the Rack and Server Precautions in the next section.
2-3 Preparing for Setup
The box the 6016T-6RFT+/6016T-6RF+ was shipped in should include two sets of rail assemblies, two rail mounting brackets and the mounting screws you will need to install the system into the rack. Follow the steps in the order given to complete the installation process in a minimum amount of time. Please read this section in its entirety before you begin the installation procedure outlined in the sections that follow.
Choosing a Setup Location
Leave enough clearance in front of the rack to enable you to open the front door completely (~25 inches) and approximately 30 inches of clearance in the back of the rack to allow for suffi cient airfl ow and ease in servicing.This product is for
2-2
SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's Manual
!
!
Warnings and Precautions!
installation only in a Restricted Access Location (dedicated equipment rooms, service closets and the like).
This product is not suitable for use with visual display work place devices acccording to §2 of the the German Ordinance for Work with Visual Display Units.
Rack Precautions
Ensure that the leveling jacks on the bottom of the rack are fully extended to the fl oor with the full weight of the rack resting on them.
In single rack installation, stabilizers should be attached to the rack. In multiple rack installations, the racks should be coupled together.
Always make sure the rack is stable before extending a component from the rack.
You should extend only one component at a time - extending two or more si- multaneously may cause the rack to become unstable.
Server Precautions
Review the electrical and general safety precautions in Chapter 4.
Determine the placement of each component in the rack before you install the rails.
Install the heaviest server components on the bottom of the rack fi rst, and then work up.
Use a regulating uninterruptible power supply (UPS) to protect the server from power surges, voltage spikes and to keep your system operating in case of a power failure.
Allow the hot plug SAS/SATA drives and power supply modules to cool before touching them.
Always keep the rack's front door and all panels and components on the servers
closed when not servicing to maintain proper cooling.
Chapter 2: Server Installation
2-3
Rack Mounting Considerations
Ambient Operating Temperature
If installed in a closed or multi-unit rack assembly, the ambient operating tempera­ture of the rack environment may be greater than the ambient temperature of the room. Therefore, consideration should be given to installing the equipment in an environment compatible with the manufacturer’s maximum rated ambient tempera­ture (Tmra).
Reduced Airfl ow
Equipment should be mounted into a rack so that the amount of airfl ow required for safe operation is not compromised.
Mechanical Loading
Equipment should be mounted into a rack so that a hazardous condition does not arise due to uneven mechanical loading.
Circuit Overloading
Consideration should be given to the connection of the equipment to the power supply circuitry and the effect that any possible overloading of circuits might have on overcurrent protection and power supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.
Reliable Ground
A reliable ground must be maintained at all times. To ensure this, the rack itself should be grounded. Particular attention should be given to power supply connec­tions other than the direct connections to the branch circuit (i.e. the use of power strips, etc.).
2-4
SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's Manual
2-4 Installing the System into a Rack
This section provides information on installing the 6016T-6RFT+/6016T-6RF+ into a rack unit with the rack rails provided. If the system has already been mounted into a rack, you can skip ahead to Sections 2-5 and 2-6. There are a variety of rack units on the market, which may mean the assembly procedure will differ slightly. You should also refer to the installation instructions that came with the rack unit
you are using.
Identifying the Sections of the Rack Rails
You should have received two rack rail assemblies in the rack mounting kit. Each assembly consists of two sections: an inner fi xed chassis rail that secures directly to the server chassis and an outer fi xed rack rail that secures directly to the rack itself (see Figure 2-1). Two pairs of short brackets to be used on the front side of the outer rails are also included.
Installing the Inner Rails
Both the left and right side inner rails have been pre-attached to the chassis. Pro­ceed to the next step.
Figure 2-1. Identifying the Sections of the Rack Rails
(left side rail shown)
Inner Rail Outer RailLocking Tab
Chapter 2: Server Installation
2-5
Installing the Outer Rails
Installing the Outer Rails to the Rack
Measure the distance from the front rail to the rear rail of the rack. 1.
Attach a short bracket to the front side of the right outer rail and a long 2. bracket to the rear side of the right outer rail.
Adjust both the short and long brackets to the proper distance so that the rail 3. can fi t snugly into the rack.
Secure the short bracket to the front side of the outer rail with two M4 screws 4. and the long bracket to the rear side of the outer rail with three M4 screws.
Repeat these steps for the left outer rail.5.
Locking Tabs
Both chassis rails have a locking tab, which serves two functions. The fi rst is to lock the server into place when installed and pushed fully into the rack, which is its normal position. Secondly, these tabs also lock the server in place when fully extended from the rack. This prevents the server from coming completely out of the rack when you pull it out for servicing.
Figure 2-2. Installing the Rack Rails
2-6
SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's Manual
Installing the Server into the Rack
Installing the Chassis into a Rack (Figure 2-3)
Confi rm that chassis includes the inner rails and rail extensions . Also, confi rm 1. that the outer rails are installed on the rack.
Line chassis rails with the front of the rack rails.2.
Slide the chassis rails into the rack rails, keeping the pressure even on both 3. sides (you may have to depress the locking tabs when inserting). When the server has been pushed completely into the rack, you should hear the locking tabs "click".
(Optional) Insert and tightening the thumbscrews that hold the front of the 4. server to the rack.
Installing the Server into a Telco Rack
To install the 6016T-6RFT+/6016T-6RF+ into a Telco type rack, use two L-shaped brackets on either side of the chassis (four total). First, determine how far follow the server will extend out the front of the rack. Larger chassis should be positioned to balance the weight between front and back. If a bezel is included on your server, remove it. Then attach the two front brackets to each side of the chassis, then the two rear brackets positioned with just enough space to accommodate the width of the telco rack. Finish by sliding the chassis into the rack and tightening the brackets to the rack.
Chapter 2: Server Installation
2-7
Figure 2-3. Installing the Server into a Rack
2-8
SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's Manual
2-5 Checking the Serverboard Setup
After you install the system in the rack, you will need to open the top cover to make sure the serverboard is properly installed and all the connections have been made.
Accessing the Inside of the System
First, grasp the two handles on either side and pull the system straight out 1. until it locks (you will hear a "click").
Next, press the two buttons on the top of the chassis to release the top cover.2.
Push the cover away from you (toward the rear of the chassis) until it stops. 3. You can then lift the top cover from the chassis to gain full access to the inside of the server.
To remove the system from the rack completely, press the locking tabs in 4. the chassis rails (push the right-side tab down and the left-side tab up) to continue to pull the system out past the locked position.
Checking the Components
You may have one or two processors already installed in the serverboard. 1. Each processor needs its own heatsink. See Chapter 5 for instructions on processor and heatsink installation.
Your server system may have come with system memory already installed. 2. Make sure all DIMMs are fully seated in their slots. For details on adding system memory, refer to Chapter 5.
If desired, you can install an add-on card to the system. See Chapter 5 for 3. details on installing PCI add-on cards.
Make sure all power and data cables are properly connected and not blocking 4. the chassis airfl ow. See Chapter 5 for details on cable connections.
Chapter 2: Server Installation
2-9
Figure 2-4. Accessing the Inside of the System
2-10
SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's Manual
2-6 Checking the Drive Bay Setup
Next, you should check to make sure the peripheral drives and the hard drives and backplane have been properly installed and all connections have been made.
Checking the Drives
All drives are accessable from the front of the server. The hard disk drives 1. can be installed and removed from the front of the chassis without removing the top chassis cover.
A slim DVD-ROM drive should be preinstalled in your server. For servicing 2. the DVD-ROM drive, you will need to remove the top chassis cover. Refer to Chapter 6 if you need to reinstall a DVD-ROM drive to the system.
Depending upon your system's confi guration, your system may have one or 3. more drives already installed. If you need to install hard drives, please refer to Chapter 6.
Checking the Airfl ow
Airfl ow is provided by fi ve sets of 4-cm fans (each set of fans consists of 1. two fans that are mounted back to back). The system component layout was carefully designed to direct suffi cient cooling airfl ow to the components that generate the most heat.
Note that all power and data cables have been routed in such a way that they 2. do not block the airfl ow generated by the fans.
Providing Power
The last thing you must do is to provide input power to the system. Plug the 1. power cord from the power supply module into a high-quality power strip that offers protection from electrical noise and power surges.
It is recommended that you use an uninterruptible power supply (UPS) 2. source.
Chapter 3: System Interface
3-1
Chapter 3
System Interface
3-1 Overview
There are several LEDs on the control panel as well as others on the hard drive carriers to keep you constantly informed of the overall status of the system as well as the activity and health of specifi c components. There are also two buttons on the chassis control panel and an on/off switch on the power supply. This chapter explains the meanings of all LED indicators and the appropriate response you may
need to take.
3-2 Control Panel Buttons
There are three push-buttons located on the front of the chassis. These are (in order from left to right) A UID button, a reset button and a power on/off button.
UID
Depressing the UID (unit identifi er) button illuminates an LED on both the front and rear of the chassis for easy system location in large stack confi gurations. The LED will remain on until the button is pushed a second time. Another UID button on the rear of the chassis serves the same function.
Reset
The reset button reboots the system.
Power
The main power switch is used to apply or remove power from the power supply to the server system. Turning off system power with this button removes the main power but keeps standby power supplied to the system.
3-2
SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's Manual
HDD
Indicates IDE channel activity . On the 6016T -6RFT+/6016T-6RF+ this light indicates HDD and/or DVD-ROM drive activity when fl ashing.
2
1
3-3 Control Panel LEDs
The control panel located on the front of the SC819TQ chassis has fi ve LEDs. These LEDs provide you with critical information related to different parts of the system. This section explains what each LED indicates when illuminated and any corrective action you may need to take.
UID/Overheat/Fan Fail/Power Fail
Blue: This LED turns on when either the front or the rear UID button is pushed. Pushing either button a second time will turn this LED off.
Red: When this LED fl ashes quickly it indicates a fan failure. When fl ashing slowly it indicates a power supply failure. When on continuously (on and not fl ashing) it indicates an overheat condition, which may be caused by cables obstructing the airfl ow in the system or the ambient room temperature being too warm. Check the routing of the cables and make sure all fans are present and operating normally. You should also check to make sure that the chassis covers are installed. Finally, verify that the heatsinks are installed properly (see Chapter 5). This LED will remain ashing or on as long as the overheat condition exists.
NIC2
Indicates network activity on GLAN2 when fl ashing .
NIC1
Indicates network activity on GLAN1 when fl ashing.
Chapter 3: System Interface
3-3
Power
Indicates power is being supplied to the system's power supply units. This LED should normally be illuminated when the system is operating.
3-4 Drive Carrier LEDs
Green: Each SAS /SATA drive car rie r has a gre en LED. When i lluminate d, this gre en LED in dic ates dr ive ac tiv it y. A connec tio n to the S AS/ SATA backpla ne enable s th is L ED to bl ink o n an d off whe n th at parti cu lar d r ive i s be ing a c c es se d. Please refer to Chapter 6 for instructions on replacing failed SAS/SATA drives.
Red: The red LED to indicate a SAS/SATA drive failure. If one of the drives fail, you should be notifi ed by your system management software. Please refer to Chapter 6 for instructions on replacing failed SAS/SATA drives.
3-4
SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's Manual
Notes
Chapter 4: System Safety
4-1
Chapter 4
System Safety
4-1 Electrical Safety Precautions
!
Basic electrical safety precautions should be followed to protect yourself from harm and the SuperServer 6016T-6RFT+/6016T-6RF+ from damage:
Be aware of the locations of the power on/off switch on the chassis as well as the room's emergency power-off switch, disconnection switch or electrical outlet. If an electrical accident occurs, you can then quickly remove power from the system.
Do not work alone when working with high voltage components.
Power should always be disconnected from the system when removing or in- stalling main system components, such as the serverboard, memory modules and fl oppy drive. When disconnecting power, you should fi rst power down the system with the operating system fi rst and then unplug the power cords of all the power supply units in the system.
When working around exposed electrical circuits, another person who is familiar with the power-off controls should be nearby to switch off the power if neces­sary.
Use only one hand when working with powered-on electrical equipment. This is to avoid making a complete circuit, which will cause electrical shock. Use extreme caution when using metal tools, which can easily damage any electrical components or circuit boards they come into contact with.
Do not use mats designed to decrease static electrical discharge as protection from electrical shock. Instead, use rubber mats that have been specifi cally designed as electrical insulators.
The power supply power cords must include a grounding plug and must be plugged into grounded electrical outlets. The unit has more than one power
4-2
SUPERSERVER 6016T-6RFT+/6016T-6RF+ User's Manual
4-2 General Safety Precautions
Follow these rules to ensure general safety:
Keep the area around the system clean and free of clutter.
The 6016T-6RFT+/6016T-6RF+ weighs approximately 38.5 lbs. (17.5 kg.) when fully loaded. When lifting the system, two people at either end should lift slowly with their feet spread out to distribute the weight. Always keep your back straight and lift with your legs.
Place the chassis top cover and any system components that have been re- moved away from the system or on a table so that they won't accidentally be stepped on.
While working on the system, do not wear loose clothing such as neckties and unbuttoned shirt sleeves, which can come into contact with electrical circuits or be pulled into a cooling fan.
!
supply cord. Disconnect both power supply cords before servicing to avoid electrical shock
Serverboard Battery: CAUTION - There is a danger of explosion if the onboard battery is installed upside down, which will reverse its polarites (see Figure 4-1). This battery must be replaced only with the same or an equivalent type recom­mended by the manufacturer (CR2032). Dispose of used batteries according to the manufacturer's instructions.
DVD-ROM Laser:
CAUTION - this server may have come equipped with a
DVD-ROM drive. To prevent direct exposure to the laser beam and hazardous radiation exposure, do not open the enclosure or use the unit in any uncon­ventional way.
Mainboard replaceable soldered-in fuses: Self-resetting PTC (Positive Tempera- ture Coeffi cient) fuses on the mainboard must be replaced by trained service technicians only. The new fuse must be the same or equivalent as the one replaced (CR2032). Contact technical support for details and support.