Super Micro SYS-7046T-NTR+ User Manual

SUPER
SUPERSERVER 7046T-NTR+
®
USER’S MANUAL
1.0
The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccuracies that may be contained in this document, makes no commitment to update or to keep current the information in this manual, or to notify any person or organization of the updates. Please Note: For the most up-to-date version of this
manual, please see our web site at www.supermicro.com.
Super Micro Computer, Inc. ("Supermicro") reserves the right to make changes to the product described in this manual at any time and without notice. This product, including software, if any, and documentation may not, in whole or in part, be copied, photocopied, reproduced, translated or reduced to any medium or machine without prior written consent.
IN NO EVENT WILL SUPERMICRO BE LIABLE FOR DIRECT, INDIRECT , SPECIAL, INCIDENTAL, SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO USE THIS PRODUCT OR DOCUMENTATION, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. IN PARTICULAR, SUPERMICRO SHALL NOT HAVE LIABILITY FOR ANY HARDWARE, SOFTW ARE, OR DA TA STORED OR USED WITH THE PRODUCT, INCLUDING THE COSTS OF REPAIRING, REPLACING, INTEGRATING, INSTALLING OR RECOVERING SUCH HARDWARE, SOFTWARE, OR DATA.
Any disputes arising between manufacturer and customer shall be governed by the laws of Santa Clara County in the State of California, USA. The State of California, County of Santa Clara shall be the exclusive venue for the resolution of any such disputes. Super Micro's total liability for all claims will not exceed the price paid for the hardware product.
FCC Statement: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the manufacturer’s instruction manual, may cause harmful interference with radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case you will be required to correct the interference at your own expense.
California Best Management Practices Regulations for Perchlorate Materials: This Perchlorate warning applies only to products containing CR (Manganese Dioxide) Lithium coin cells. “Perchlorate Material-special handling may apply. See www.dtsc.ca.gov/hazardouswaste/perchlorate”
WARNING: Handling of lead solder materials used in this product may expose you to lead, a chemical known to the State of California to cause birth defects and other reproductive harm.
Manual Revision 1.0 Release Date: May 22, 2009
Unless you request and receive written permission from Super Micro Computer, Inc., you may not copy any part of this document.
Information in this document is subject to change without notice. Other products and companies referred to herein are trademarks or registered trademarks of their respective companies or mark holders.
Copyright © 2009 by Super Micro Computer, Inc. All rights reserved.
Printed in the United States of America
Preface
About This Manual
This manual is written for professional system integrators and PC technicians. It provides information for the installation and use of the SuperServer 7046T-NTR+. Installation and maintainance should be performed by experienced technicians only.
The SuperServer 7046T-NTR+ is a high-end server based on the SC745TQ-R800B chassis and the X8DTN+ dual processor serverboard.
Manual Organization
Preface
Chapter 1: Introduction
The fi rst chapter provides a checklist of the main components included with the server system and describes the main features of the X8DTN+ serverboard and the SC745TQ-R800B chassis.
Chapter 2: Server Installation
This chapter describes the steps necessary to install the SuperServer 7046T-NTR+ into a rack and check out the server confi guration prior to powering up the system. If your server was ordered without processor and memory components, this chapter will refer you to the appropriate sections of the manual for their installation.
Chapter 3: System Interface
Refer here for details on the system interface, which includes the functions and information provided by the control panel on the chassis as well as other LEDs located throughout the system.
Chapter 4: System Safety
You should thoroughly familiarize yourself with this chapter for a general overview of safety precautions that should be followed when installing and servicing the SuperServer 7046T-NTR+.
iii
SUPERSERVER 7046T-NTR+ User's Manual
Chapter 5: Advanced Serverboard Setup
Chapter 5 provides detailed information on the X8DTN+ serverboard, including the locations and functions of connections, headers and jumpers. Refer to this chapter when adding or removing processors or main memory and when reconfi guring the serverboard.
Chapter 6: Advanced Chassis Setup
Refer to Chapter 6 for detailed information on the SC745TQ-R800B server chassis. You should follow the procedures given in this chapter when installing, removing or reconfi guring SATA or peripheral drives and when replacing system power supply units and cooling fans.
Chapter 7: BIOS
The BIOS chapter includes an introduction to BIOS and provides detailed informa­tion on running the CMOS Setup Utility.
Appendix A: BIOS Error Beep Codes
Appendix B: Installing Windows
Appendix C: System Specifi cations
iv
Notes
Preface
v
SUPERSERVER 7046T-NTR+ User's Manual
Table of Contents
Chapter 1 Introduction
1-1 Overview .........................................................................................................1-1
1-2 Serverboard Features .....................................................................................1-2
Processors ......................................................................................................1-2
Memory ...........................................................................................................1-2
Serial ATA ....................................................................................................... 1-2
PCI Expansion Slots ....................................................................................... 1-2
UIO ..................................................................................................................1-2
Onboard Controllers/Ports .............................................................................. 1-3
ATI Graphics Controller ................................................................................... 1-3
Other Features ................................................................................................1-3
1-3 Server Chassis Features ................................................................................ 1-3
System Power .................................................................................................1-3
Front Control Panel ......................................................................................... 1-3
I/O Backplane ..................................................................................................1-4
Cooling System ...............................................................................................1-4
1-4 Contacting Supermicro .................................................................................... 1-6
Chapter 2 Server Installation
2-1 Overview .........................................................................................................2-1
2-2 Unpacking the System ....................................................................................2-1
2-3 Preparing for Setup ......................................................................................... 2-1
Choosing a Setup Location .............................................................................2-2
Rack Precautions ............................................................................................2-2
Server Precautions ..........................................................................................2-2
Rack Mounting Considerations .......................................................................2-3
Ambient Operating Temperature ................................................................2-3
Reduced Airfl ow ......................................................................................... 2-3
Mechanical Loading ...................................................................................2-3
Circuit Overloading ..................................................................................... 2-3
Reliable Ground .........................................................................................2-3
2-4 Installing the System into a Rack ................................................................... 2-4
Identifying the Sections of the Rack Rails .....................................................2-4
Installing the Chassis Rails ............................................................................. 2-5
Installing the Rack Rails .................................................................................2-6
Installing the Server into the Rack ..................................................................2-7
2-5 Checking the Serverboard Setup ....................................................................2-8
vi
Table of Contents
2-6 Checking the Drive Bay Setup ........................................................................2-9
Chapter 3 System Interface
3-1 Overview .........................................................................................................3-1
3-2 Control Panel Buttons .....................................................................................3-1
Power ..............................................................................................................3-1
Reset ...............................................................................................................3-1
3-3 Control Panel LEDs ........................................................................................3-2
Power ..............................................................................................................3-2
HDD ................................................................................................................. 3-2
NIC1 ................................................................................................................3-2
NIC2 ................................................................................................................3-2
Overheat/Fan Fail ...........................................................................................3-3
Power Fail ....................................................................................................... 3-3
3- 4 Drive C arr ier LED s .........................................................................................3 -3
Chapter 4 System Safety
4-1 Electrical Safety Precautions .......................................................................... 4-1
4-2 General Safety Precautions ............................................................................4-2
4-3 ESD Precautions .............................................................................................4-3
4-4 Operating Precautions .................................................................................... 4-4
Chapter 5 Advanced Serverboard Setup
5-1 Handling the Serverboard ...............................................................................5-1
Precautions .....................................................................................................5-1
Unpacking .......................................................................................................5-2
5-2 Serverboard Installation ..................................................................................5-2
5-3 Connecting Cables ..........................................................................................5-3
Connecting Data Cables .................................................................................5-3
Connecting Power Cables .............................................................................. 5-3
Connecting the Control Panel ......................................................................... 5-3
5-4 I/O Ports .......................................................................................................... 5-4
5-5 Installing a Processor and Heatsink ............................................................... 5-5
Installing an LGA1366 Processor ................................................................... 5-5
Installing a CPU Heatsink ...............................................................................5-7
Memory Support ..............................................................................................5-8
DIMM Installation ............................................................................................5-8
Memory Support ......................................................................................... 5-9
Populating DIMMs ......................................................................................5-9
5-7 Installing PCI Expansion Cards .................................................................... 5-10
5-8 Serverboard Details .......................................................................................5-11
vii
SUPERSERVER 7046T-NTR+ User's Manual
X8DTN+ Quick Reference ............................................................................5-12
5-9 Connector Defi nitions ................................................................................... 5-13
5-10 Jumper Settings ............................................................................................5-19
5-11 Onboard Indicators ........................................................................................5-22
5-12 Floppy, IDE and SATA Ports ......................................................................... 5-23
5-13 Installing Software .........................................................................................5-25
Supero Doctor III ........................................................................................... 5-26
Chapter 6Advanced Chassis Setup
6-1 Static-Sensitive Devices .................................................................................. 6-1
Precautions .....................................................................................................6-1
6-2 Front Control Panel ......................................................................................... 6-3
6-3 System Fans ...................................................................................................6-4
Fan Failure ......................................................................................................6-4
6-4 Drive Bay Installation ...................................................................................... 6-6
SATA Drives .................................................................................................... 6-6
SATA Backplane ..............................................................................................6-7
Storage Module ............................................................................................... 6-9
Adding Drives to the Storage Module ...................................................... 6-10
Using a Mobile Rack ..................................................................................... 6-10
6-5 Power Supply .................................................................................................6-11
Power Supply Failure .....................................................................................6-11
Removing/Replacing the Power Supply .........................................................6-11
Chapter 7 BIOS
7-1 Introduction ...................................................................................................... 7-1
Starting BIOS Setup Utility ..............................................................................7-1
How To Change the Confi guration Data .........................................................7-1
Starting the Setup Utility ................................................................................. 7-2
7-2 Main Setup ...................................................................................................... 7-2
7-3 Advanced Setup Confi gurations...................................................................... 7-4
4-4 Security Settings ..................................................................................................
4-5 Boot Confi guration ...............................................................................................
7-4 Security Settings ...........................................................................................7-24
7-5 Boot Confi guration ........................................................................................ 7-25
7-6 Exit Options ...................................................................................................7-26
Appendix A BIOS Error Beep Codes Appendix B Installing Windows Appendix C System Specifi cations
viii
Chapter 1: Introduction
Chapter 1
Introduction
1-1 Overview
The SuperServer 7046T-NTR+ is a high-end server comprised of two main sub­systems: the SC745TQ-R800B server chassis and the X8DTN+ dual processor serverboard. Please refer to our web site for information on operating systems that have been certifi ed for use with the system (www.supermicro.com).
In addition to the serverboard and chassis, various hardware components have been included with the 7046T-NTR+, as listed below:
Two passive heatsinks (SNK-P0038P)
Three 8-cm chassis fans (FAN-0074L4)
Two exhaust fans (FAN-0082L4)
One air shroud (MCP-310-48001-0N)
SATA Accessories One SATA backplane (CSE-SAS-743TQ) One 2-ft. SATA cable (CBL-0044L) Two 35-cm SATA cables (CBL-0061L) Two 40-cm SGPIO cables (CBL-0157L) Eight drive carriers (CSE-PT17-B)
One rackmount kit, optional (CSE-PT26)
One CD containing drivers and utilities
SuperServer 7046T-NTR+ User's Manual
1-1
SUPERSERVER 7046T-NTR+ User's Manual
1-2 Serverboard Features
At the heart of the SuperServer 7046T-NTR+ lies the X8DTN+, a dual processor serverboard based on the Intel 5520 + ICH10R chipset and designed to provide maximum performance. Below are the main features of the X8DTN+. (See Figure 1-1 for a block diagram of the chipset).
Processors
The X8DTN+ supports single or dual Intel® Xeon® 5500 processors and future Intel Nehalem processor families (next generation Intel Xeon processor). Please refer to the serverboard description pages on our web site for a complete listing of supported processors (www.supermicro.com).
Memory
The X8DTN+ has eighteen DIMM slots that can support up to 144 GB of DDR3­1333/1066/800 registered ECC SDRAM. The memory operates in an interleaved confi guration and requires requires modules of the same size and speed to be installed two at a time. See Chapter 5 for details.
Serial ATA
A Serial ATA controller is integrated into the ICH10R (South Bridge) portion of the IOH-36D chipset to provide a six-port 3 Gb/s SATA subsystem, which is RAID 0, 1, 10 and 5 supported. The SATA drives are hot-swappable units.
Note: The operati ng system yo u use must h ave R AID su ppor t to e nable t he hot­swap capability and RAI D function of the SATA drives.
PCI Expansion Slots
The X8DTN+ has two PCI Express 2.0 x8 slots, one PCI Express x4 slot (in a x8 slot), three 64-bit 133/100 MHz PCI-X slots and one UIO slot (see below).
UIO
The X8DTN+ is a spe c ial ly-de sig ne d se r ve r bo ard t hat f eatu re s Sup er m ic ro's U IO (Univer sal I/O) techno logy. UIO ser verboar ds have a PCI- Expr ess x8 co nnector that can s uppor t any one of s everal ty pes of UIO c ard t ypes (l ow-pr ofi le only) to add SAS ports, additional LAN ports, etc. to the serverboard. This allows the user to tailo r the se rve rboa rd to the ir own nee ds.
Note: the 7046T- NTR+ doe s not co me wit h a UIO c ard pre - insta lled.
1-2
Chapter 1: Introduction
Onboard Controllers/Ports
A fl oppy drive connector is included on the serverboard as well as one onboard ATA/100 connector, which supports IDE hard drives or ATAPI devices. The color­coded I/O ports include one COM port (an additional COM header is located on the serverboard), a VGA (monitor) port, two USB 2.0 ports (two additional USB headers and one Type A port are included on the serverboard), PS/2 mouse and keyboard ports and two gigabit Ethernet ports.
ATI Graphics Controller
The X8DTN+ features an integrated ATI video controller based on the ES1000 32 MB graphics chip. The ES1000 was designed specifi cally for servers, featuring low power consumption, high reliability and superior longevity.
Other Features
Other onboard features that promote system health include onboard voltage moni­tors, a chassis intrusion header, auto-switching voltage regulators, chassis and CPU overheat sensors, virus protection and BIOS rescue.
1-3 Server Chassis Features
The following is a general outline of the main features of the SC745TQ-R800B server chassis.
System Power
The SC745TQ-R800B features a redundant 800W power supply composed of two separate power modules. This power redundancy feature allows you to replace a failed power supply without shutting down the system.
Front Control Panel
The control panel on the SuperServer 7046T-NTR+ provides you with system monitoring and control. LEDs indicate system power, HDD activity, network activity, system overheat and power supply failure. A main power button and a system reset button are also included. In addition, two USB ports have been incorporated into the control panel to provide front side USB access.
1-3
SUPERSERVER 7046T-NTR+ User's Manual
I/O Backplane
The SC745TQ-R800B is an Extended ATX form factor chassis that may be used in either a tower or a 4U rackmount confi guration. The I/O backplane provides seven tool-less motherboard expansion slots, one COM port, one parallel port, one VGA port, two USB 2.0 ports, PS/2 mouse and keyboard ports and two gigabit Ethernet ports.
Cooling System
The chassis has an innovative cooling design that includes three 8-cm hot-plug system cooling fans located in the middle section of the chassis as well as two 8-cm hot-plug exhaust fans located at the rear of the chassis. An air shroud channels the airfl ow from the system fans to effi ciently cool the processor area of the system. The power supply module also includes a cooling fan.
1-4
Chapter 1: Introduction
Figure 1-1. Intel 5520/ICH10R Chipset:
System Block Diagram
Note: This is a general block diagram. Please see Chapter 5 for details.
#1
#1
#1
DDR3 DIMM
A
B
#2
#2
#2
#2
DDR3 DIMM
#1
PCI-x Slot
PCI-x Slot
A
B
CC
#3
Chnl A
PCI-x Slot
Chnl B
JMB368
IDE
#3
#3
#3
#4
#0
PCI-E x8 Slot
#5
A
B
CPU1
C
DDR3 DIMM
#6
PCI-E x8 Slot
SEPC
J11
PCI-Ex16 Slot
PXH
x1
PE
5
x4
PE 4-1
PCI-E x8 Slot
SIMLP
DDR2
CSI
Port1 Port0 Ports
3,4
Intel 5520
Ports
5,6
Ports
Ports
7,8
PCI
9,10
VGA
ES1000
ESI
DMI
SATA
CPU2
Ports
1,2
CLINK
CLINK
ICH10R
SATA #1 SATA #2 SATA #3 SATA #4 SATA #5 SATA #6
D
E
F
#3
#3
#3
DDR3 DIMM
82575
RJ45RJ45
SST25
VF016
SPI
LPC
SIO
83627
Floppy
D
E
F
#2
#2
#2
DDR3 DIMM
D
E
F
#1
#1
#1
DDR3 DIMM
VGA
1-5
SUPERSERVER 7046T-NTR+ User's Manual
1-4 Contacting Supermicro
Headquarters
Address: Super Micro Computer, Inc.
980 Rock Ave. San Jose, CA 95131 U.S.A.
Tel: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: marketing@supermicro.com (General Information)
support@supermicro.com (Technical Support)
Web Site: www.supermicro.com
Europe
Address: Super Micro Computer B.V.
Het Sterrenbeeld 28, 5215 ML 's-Hertogenbosch, The Netherlands
Tel: +31 (0) 73-6400390 Fax: +31 (0) 73-6416525 Email: sales@supermicro.nl (General Information)
support@supermicro.nl (Technical Support) rma@supermicro.nl (Customer Support)
Asia-Pacifi c
Address: Super Micro Computer, Inc.
4F, No. 232-1, Liancheng Rd. Chung-Ho 235, Taipei County Taiwan, R.O.C.
Tel: +886-(2) 8226-3990 Fax: +886-(2) 8226-3991 Web Site: www.supermicro.com.tw Technical Support: Email: support@supermicro.com.tw Tel: 886-2-8228-1366, ext.132 or 139
1-6
Chapter 2: Server Installation
Chapter 2
Server Installation
2-1 Overview
This chapter provides a quick setup checklist to get your SuperServer 7046T-NTR+ up and running. Following these steps in the order given should enable you to have the system operational within a minimum amount of time. This quick setup assumes that your system has come to you with the processors and memory preinstalled. If your system is not already fully integrated with a serverboard, processors, system memory etc., please turn to the chapter or section noted in each step for details on installing specifi c components.
The 7046T-NTR+ may be employed either as a tower or mounted in a rack as a 4U rackmount chassis. If using it as a tower unit, please read the Server Precautions in the next section and then skip ahead to Section 2-5.
2-2 Unpacking the System
You should inspect the box the system was shipped in and note if it was damaged in any way. If the server itself shows damage you should fi le a damage claim with the carrier who delivered it.
Decide on a suitable location for the SuperServer 7046T-NTR+. It should be situated in a clean, dust-free area that is well ventilated. Avoid areas where heat, electrical noise and electromagnetic fi elds are generated. You will also need it placed near a grounded power outlet. Be sure to read the Rack and Server Precautions in the next section.
2-3 Preparing for Setup
The box the system was shipped in may include two sets of rail assemblies, two rail mounting brackets and mounting screws needed for installing the system into a rack (optional kit). Follow the steps in the order given to complete the installation process in a minimum amount of time. Please read this section in its entirety before you begin the installation procedure outlined in the sections that follow.
2-1
SUPERSERVER 7046T-NTR+ User's Manual
!
!
Choosing a Setup Location
Leave enough clearance in front of the rack to enable you to open the front door completely (~25 inches) and approximately 30 inches of clearance in the back of the rack to allow for suffi cient airfl ow and ease in servicing.
This product is for installation only in a Restricted Access Location (dedicated equipment rooms, service closets and the like).
This product is not suitable for use with visual display work place devices
acccording to §2 of the the German Ordinance for Work with Visual Display Units.
Warnings and Precautions!
Rack Precautions
Ensure that the leveling jacks on the bottom of the rack are fully extended to the fl oor with the full weight of the rack resting on them.
In single rack installation, stabilizers should be attached to the rack. In multiple
rack installations, the racks should be coupled together.
Always make sure the rack is stable before extending a component from the
rack.
You should extend only one component at a time - extending two or more si-
multaneously may cause the rack to become unstable.
Server Precautions
Review the electrical and general safety precautions in Chapter 4.
Determine the placement of each component in the rack before you install the rails.
Install the heaviest server components on the bottom of the rack fi rst, and then
work up.
Use a regulating uninterruptible power supply (UPS) to protect the server from
power surges, voltage spikes and to keep your system operating in case of a power failure.
2-2
Chapter 2: Server Installation
Allow the hot plug SATA drives and power supply modules to cool before touch- ing them.
Always keep the rack's front door and all panels and components on the servers
closed when not servicing to maintain proper cooling.
Rack Mounting Considerations
Ambient Operating Temperature
If installed in a closed or multi-unit rack assembly, the ambient operating tempera­ture of the rack environment may be greater than the ambient temperature of the room. Therefore, consideration should be given to installing the equipment in an environment compatible with the manufacturer’s maximum rated ambient tempera­ture (Tmra).
Reduced Airfl ow
Equipment should be mounted into a rack so that the amount of airfl ow required for safe operation is not compromised.
Mechanical Loading
Equipment should be mounted into a rack so that a hazardous condition does not arise due to uneven mechanical loading.
Circuit Overloading
Consideration should be given to the connection of the equipment to the power supply circuitry and the effect that any possible overloading of circuits might have on overcurrent protection and power supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.
Reliable Ground
A reliable ground must be maintained at all times. To ensure this, the rack itself should be grounded. Particular attention should be given to power supply connec­tions other than the direct connections to the branch circuit (i.e. the use of power strips, etc.).
2-3
SUPERSERVER 7046T-NTR+ User's Manual
Inner rail
Outer rail
Rail brackets
2-4 Installing the System into a Rack
This section provides information on installing the system into a rack unit. Rack installation requires the use of the optional rackmount kit. If the system has already been mounted into a rack or if you are using it as a tower, you can skip ahead to Sections 2-5 and 2-6.
There are a variety of rack units on the market, which may mean the assembly procedure will differ slightly. The following is a guideline for installing the server into a rack with the rack rails provided in the rackmount kit. You should also refer to the
installation instructions that came with the rack unit you are using.
Identifying the Sections of the Rack Rails
The optional rackmount kit includes two rack rail assemblies. Each of these as­semblies consist of three sections: an inner fi xed chassis rail that secures to the chassis, an outer rack rail that secures directly to the rack itself and two rail brackets, which also attack to the rack (see Figure 2-1.) The inner and outer rails must be detached from each other to install.
To remove the inner chassis rail, pull it out as far as possible - you should hear a "click" sound as a locking tab emerges from inside the rail assembly and locks the inner rail. Depress the locking tab to pull the inner rail completely out. Do this for both assemblies (one for each side).
Figure 2-1. Identifying the Sections of the Rack Rails
2-4
Chapter 2: Server Installation
Installing the Chassis Rails
You will need to remove the top cover and the feet to add rack rails to the chassis. First, remove the top and right covers (top and left covers when standing as a tower chassis) by fi rst removing the screws that secure them to the chassis. Depress the button on the top (side if tower) of the chassis to release the cover and then pull the cover off. Then unscrew the four feet and remove them from the chassis (see Figure 2-2).
You can now attach rack rails to the top and bottom (now the sides) of the chassis. First add the rack handles. Then position the inner chassis rail sections you just removed along the side of the chassis making sure the screw holes line up. Note that these two rails are left/right specifi c. Screw the rail securely to the side of the chassis (see Figure 2-3). Repeat this procedure for the other rail on the other side of the chassis. You will also need to attach the rail brackets when installing into a telco rack.
Locking Tabs: As mentioned, the chassis rails have a locking tab, which serves two functions. The fi rst is to lock the server into place when installed and pushed fully into the rack, which is its normal position. Secondly, these tabs also lock the server in place when fully extended from the rack. This prevents the server from coming completely out of the rack when you pull it out for servicing.
Figure 2-2. Preparing to Install the Chassis Rails
2-5
SUPERSERVER 7046T-NTR+ User's Manual
Figure 2-3. Installing the Rails to the Chassis
Installing the Rack Rails
Determine where you want to place the SuperServer 7046T-NTR+ in the rack. (See Rack and Server Precautions in Section 2-3.) Position the fi xed rack rail/sliding rail guide assemblies at the desired location in the rack, keeping the sliding rail guide facing the inside of the rack. Screw the assembly securely to the rack using the brackets provided. Attach the other assembly to the other side of the rack, making sure both are at the exact same height and with the rail guides facing inward.
2-6
Chapter 2: Server Installation
Installing the Server into the Rack
You should now have rails attached to both the chassis and the rack unit. The next step is to install the server into the rack. You should have two brackets in the rack mount kit. Install these fi rst keeping in mind that they are left/right specifi c (marked with "L" and "R"). Then, line up the rear of the chassis rails with the front of the rack rails. Slide the chassis rails into the rack rails, keeping the pressure even on both sides (you may have to depress the locking tabs when inserting).
When the server has been pushed completely into the rack, you should hear the locking tabs "click". Finish by inserting and tightening the thumbscrews that hold the front of the server to the rack (see Figure 2-4).
Figure 2-4. Installing the Server into a Rack
2-7
SUPERSERVER 7046T-NTR+ User's Manual
2-5 Checking the Serverboard Setup
After setting up the the system, you will need to open the unit to make sure the serverboard is properly installed and all the connections have been made.
Accessing the Inside of the System
If rack mounted, fi rst release the retention screws that secure the unit to the 1. rack.
Grasp the two handles on either side and pull the unit straight out until it 2. locks (you will hear a "click").
There are two screws that secure the cover to the chassis - remove these 3. rst.
Locate the latch on the top (side if tower) of the chassis - depress where it 4. says "push" then lift the latch to release the cover.
Lift the cover from the chassis to gain full access to the inside of the server. 5. See Figure 2-5.
Checking the Components and Setup
You may have one or two processors already installed into the serverboard. 1. Each processor should have its own heatsink attached. See Chapter 5 for instructions on processor installation.
Your server may have come with system memory already installed. Make 2. sure all DIMMs are fully seated in their slots. For details on adding system memory, refer to Chapter 5.
If desired, you can install add-on cards to the system. See Chapter 5 for 3. details on installing PCI add-on cards.
Make sure all power and data cables are properly connected and not blocking 4. the chassis airfl ow. See Chapter 5 for details on cable connections.
2-8
Chapter 2: Server Installation
2-6 Checking the Drive Bay Setup
Next, you should check to make sure the peripheral drives and then SA T A drives and backplane have been properly installed and all connections have been made.
Checking the Drives
All drives can be accessed from the front of the server. For servicing the CD-1. ROM, IDE hard drives and fl oppy drives, you will need to remove the top/left chassis cover. The SATA disk drives can be installed and removed from the front of the chassis without removing any chassis covers.
To install components into the 5.25" drive bays, you must fi rst remove the 2. top/left chassis cover as described in the previous section. Refer to Chapter 6 for details.
Refer to Chapter 6 if you need to reinstall a CD-ROM and/or fl oppy disk drive 3. to the system.
Depending upon your system's confi guration, your system may have one or 4. more drives already installed. If you need to install SATA drives, please refer to Chapter 6.
Checking the Airfl ow
Airfl ow is provided by four hot-swap 8-cm chassis fans working in conjunction 1. with an air shroud. Two 8-cm exhaust fans are also mounted at the rear of the chassis. The system component layout was carefully designed to promote suffi cient airfl ow through the chassis.
Note that all power and data cables have been routed in such a way that they 2. do not block the airfl ow generated by the fans. Keep this in mind when you reroute them after working on the system.
Supplying Power to the System
The last thing you must do is to provide input power to the system.
Plug the power cords from the power supplies unit into a high-quality power 1. strip that offers protection from electrical noise and power surges.
It is recommended that you use an uninterruptible power supply (UPS).2.
Depress the power on button on the front of the chassis.3.
2-9
SUPERSERVER 7046T-NTR+ User's Manual
Figure 2-5. Accessing the Inside of the System
(Rack Confi guration shown)
2-10
Chapter 3: System Interface
Chapter 3
System Interface
3-1 Overview
The control panel on the 7046T-NTR+ has several LEDs and two buttons. There are also two LEDs on each SATA drive carrier. These LEDs keep you constantly informed of the overall status of the system and the activity and health of specifi c components.
3-2 Control Panel Buttons
There are two push-buttons located on the front of the chassis: a power on/off button and a reset button.
Power
This is the main power button, which is used to apply or turn off the main system power. T urning off system power with this button removes the main power but keeps standby power supplied to the system.
Reset
Use the reset button to reboot the system.
3-1
SUPERSERVER 7046T-NTR+ User's Manual
3-3 Control Panel LEDs
The control panel located on the front of the SC745 chassis has six LEDs that provide you with critical information related to different parts of the system. This section explains what each LED indicates when illuminated and any corrective ac­tion you may need to take.
Power
Indicates power is being supplied to the system's power supply. This LED should normally be on when the system is operating.
HDD
Indicates IDE channel activity. On the 7046T-NTR+, this LED indicates SATA drive activity when fl ashing.
1
NIC1
Indicates network activity on LAN1 when fl ashing.
2
NIC2
Indicates network activity on LAN2 when fl ashing.
3-2
Chapter 3: System Interface
Overheat/Fan Fail
When this LED fl ashes, it indicates a fan failure. When on continuously it indicates an overheat condition, which may be caused by cables obstructing the airfl ow in the system or the ambient room temperature being too warm. Check the routing of the cables and make sure all fans are present and operating normally. You should also check to make sure that the chassis covers are installed. Finally, verify that the heatsinks are installed properly (see Chapter 5). This LED will remain fl ashing or on as long as the indicated condition exists.
Power Fail
Indicates a power supply module has failed. This should be accompanied by an audible alarm. A backup power supply module will take the load and keep the system running but the failed module will need to be replaced. Refer to Chapter 6 for details on replacing the power supply. This LED should be off when the system is operating normally.
3- 4 Drive Carrie r LEDs
Green: Each Ser i al ATA drive carr ie r ha s a gr ee n LED. Wh en i ll umi nate d, t hi s
green LED (on th e front of the SATA drive c arrier) indi cates drive ac tivity. A conne cti on to th e SATA backpla ne enab les th is LED to bl ink on an d off w hen that particular drive is being accessed. Please refer to Chapter 6 for instructions on replacing failed SATA drives.
Red:
The red LED to indicate an SATA drive failure. If one of the SATA drives
fail, you should be notifi ed by your system management software. Please refer to Chapter 6 for instructions on replacing failed SATA drives.
3-3
SUPERSERVER 7046T-NTR+ User's Manual
Notes
3-4
Chapter 4: System Safety
!
Chapter 4
System Safety
4-1 Electrical Safety Precautions
Basic electrical safety precautions should be followed to protect yourself from harm and the SuperServer 7046T-NTR+ from damage:
Be aware of the locations of the power on/off switch on the chassis as well
as the room's emergency power-off switch, disconnection switch or electrical outlet. If an electrical accident occurs, you can then quickly remove power from the system.
Do not work alone when working with high voltage components.
Power should always be disconnected from the system when removing or in- stalling main system components, such as the serverboard, memory modules and fl oppy drive. When disconnecting power, you should fi rst power down the operating system fi rst and then unplug the power cords. The unit has more than one power supply cord. Disconnect both power supply cords before servicing to avoid electrical shock.
When working around exposed electrical circuits, another person who is familiar
with the power-off controls should be nearby to switch off the power if neces­sary.
Use only one hand when working with powered-on electrical equipment. This
is to avoid making a complete circuit, which will cause electrical shock. Use extreme caution when using metal tools, which can easily damage any electrical components or circuit boards they come into contact with.
Do not use mats designed to decrease static electrical discharge as protection
from electrical shock. Instead, use rubber mats that have been specifi cally designed as electrical insulators.
The power supply power cords must include a grounding plug and must be
plugged into grounded electrical outlets.
4-1
SUPERSERVER 7046T-NTR+ User's Manual
!
Serverboard Battery: CAUTION - There is a danger of explosion if the onboard battery is installed upside down, which will reverse its polarites (see Figure 4-1). This battery must be replaced only with the same or an equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer's instructions.
DVD-ROM Laser:
CAUTION - this server may have come equipped with a
DVD-ROM drive. To prevent direct exposure to the laser beam and hazardous radiation exposure, do not open the enclosure or use the unit in any uncon­ventional way.
Mainboard replaceable soldered-in fuses: Self-resetting PTC (Positive Tempera-
ture Coeffi cient) fuses on the mainboard must be replaced by trained service technicians only. The new fuse must be the same or equivalent as the one replaced. Contact technical support for details and support.
4-2 General Safety Precautions
Follow these rules to ensure general safety:
Keep the area around the 7046T-NTR+ clean and free of clutter.
The 7046T-NTR+ weighs approximately 70 lbs (31.8 kg.) when fully loaded. When lifting the system, two people at either end should lift slowly with their feet spread out to distribute the weight. Always keep your back straight and lift with your legs.
Place the chassis top cover and any system components that have been re-
moved away from the system or on a table so that they won't accidentally be stepped on.
While working on the system, do not wear loose clothing such as neckties and
unbuttoned shirt sleeves, which can come into contact with electrical circuits or be pulled into a cooling fan.
Remove any jewelry or metal objects from your body, which are excellent metal
conductors that can create short circuits and harm you if they come into contact with printed circuit boards or areas where power is present.
4-2
Chapter 4: System Safety
!
After accessing the inside of the system, close the system back up and secure it to the rack unit with the retention screws after ensuring that all connections have been made.
4-3 ESD Precautions
Electrostatic Discharge (ESD) is generated by two objects with different electrical charges coming into contact with each other. An electrical discharge is created to neutralize this difference, which can damage electronic com ponents and printed circuit boards. The following measures are generally suffi cient to neutralize this difference before contact is made to protect your equipment from ESD:
Use a grounded wrist strap designed to prevent static discharge.
Keep all components and printed circuit boards (PCBs) in their antistatic bags until ready for use.
Touch a grounded metal object before removing the board from the antistatic
bag.
Do not let components or PCBs come into contact with your clothing, which may
retain a charge even if you are wearing a wrist strap.
Handle a board by its edges only; do not touch its components, peripheral chips,
memory modules or contacts.
When handling chips or modules, avoid touching their pins.
Put the serverboard and peripherals back into their antistatic bags when not in use.
For grounding purposes, make sure your computer chassis provides excellent
conductivity between the power supply, the case, the mounting fasteners and the serverboard.
4-3
SUPERSERVER 7046T-NTR+ User's Manual
!
4-4 Operating Precautions
Care must be taken to assure that the chassis cover is in place when the 7046T­NTR+ is operating to assure proper cooling. Out of warranty damage to the system can occur if this practice is not strictly followed.
Figure 4-1. Installing the Onboard Battery
LITHIUM BATTERY
LITHIUM BATTERY
OR
BATTERY HOLDER BATTERY HOLDER
4-4
Chapter 5: Advanced Serverboard Setup
Chapter 5
Advanced Serverboard Setup
This chapter covers the steps required to install the X8DTN+ serverboard into the chassis, connect the data and power cables and install add-on cards. All serverboard jumpers and connections are also described. A layout and quick reference chart are included in this chapter for your reference. Remember to completely close the chassis when you have fi nished working with the serverboard to better cool and protect the system.
5-1 Handling the Serverboard
Electrostatic Discharge (ESD) can damage electronic com ponents. T o prevent dam­age to any printed circuit boards (PCBs), it is important to handle them very carefully (see previous chapter). To prevent the serverboard from bending, keep one hand under the center of the board to support it when handling. The following measures are generally suffi cient to protect your equipment from electric static discharge.
Precautions
Use a grounded wrist strap designed to prevent Electrostatic Discharge (ESD).
Touch a grounded metal object before removing any board from its antistatic
bag.
Handle a board by its edges only; do not touch its components, peripheral chips,
memory modules or gold contacts.
When handling chips or modules, avoid touching their pins.
Put the serverboard, add-on cards and peripherals back into their antistatic bags when not in use.
For grounding purposes, make sure your computer chassis provides excellent
conductivity between the power supply, the case, the mounting fasteners and the serverboard.
5-1
SUPERSERVER 7046T-NTR+ User's Manual
Unpacking
The serverboard is shipped in antistatic packaging to avoid electrical static dis­charge. When unpacking the board, make sure the person handling it is static protected.
5-2 Serverboard Installation
This section explains the fi rst step of physically mounting the X8DTN+ into the SC745TQ-R800B chassis. Following the steps in the order given will eliminate the most common problems encountered in such an installation. To remove the serverboard, follow the procedure in reverse order.
Installing to the Chassis
Access the inside of the system by removing the screws from the back lip of 1. the top cover of the chassis, then pull the cover off.
Make sure that the I/O ports on the serverboard align properly with their 2. respective holes in the I/O shield at the back of the chassis.
Carefully mount the serverboard to the serverboard tray by aligning the board 3. holes with the raised metal standoffs that are visible in the chassis.
Insert screws into all the mounting holes on your serverboard that line up 4. with the standoffs and tighten until snug (if you screw them in too tight, you might strip the threads). Metal screws provide an electrical contact to the serverboard ground to provide a continuous ground for the system.
Finish by replacing the top cover of the chassis.5.
Warning: To avoid damaging the motherboard and its components, do not apply any force greater than 8 lbs. per square inch when installing a screw into a mount­ing hole.
5-2
Chapter 5: Advanced Serverboard Setup
5-3 Connecting Cables
Now that the serverboard is installed, the next step is to connect the cables to the board. These include the data cables for the peripherals and control panel and the power cables.
Connecting Data Cables
The cables used to transfer data from the peripheral devices have been carefully routed to prevent them from blocking the fl ow of cooling air that moves through the system from front to back. If you need to disconnect any of these cables, you should take care to keep them routed as they were originally after reconnecting them (make sure the red wires connect to the pin 1 locations). The following data cables (with their locations noted) should be connected. (See the layout on page 5-10 for connector locations.)
SATA drive data cables (I-SATA0 ~ I-SATA5)
Control Panel cable (JF1)
USB cable for front side access (USB2/3)
Important! Make sure the the cables do not come into contact with the fans.
Connecting Power Cables
The X8DTN+ has a 24-pin primary power supply connector (JPW1) for connection to the ATX power supply. In addition, there are two 8-pin 12V processor power connectors (JPW3 and JPW4) that must be connected to your power supply. See Section 5-9 for power connector pin defi nitions.
Connecting the Control Panel
JF1 contains header pins for various front control panel connectors. See Figure 5-1 for the pin locations of the various front control panel buttons and LED indicators.
All JF1 wires have been bundled into a single cable to simplify this connection. Make sure the red wire plugs into pin 1 as marked on the board. The other end connects to the Control Panel PCB board, located just behind the system status LEDs on the chassis. See Chapter 5 for details and pin descriptions.
5-3
SUPERSERVER 7046T-NTR+ User's Manual
Figure 5-1. Control Panel Header Pins
20 19
Ground
NMI
x (Key)
Power On LED
HDD LED NIC1 LED NIC2 LED
OH/Fan Fail LED
Power Fail LED
Ground Ground
2 1
x (Key) Vcc Vcc Vcc Vcc Vcc Vcc Reset (Button) Power (Button)
5-4 I/O Ports
The I/O ports are color coded in conformance with the PC 99 specifi cation. See Figure 5-2 below for the colors and locations of the various I/O ports.
Mouse (Green)
Keyboard
(Purple)
USB01
USB0
Figure 5-2. I/O Ports
COM1 Port
(Turquoise)
5-4
LAN1 LAN2
VGA Port
(Blue)
Chapter 5: Advanced Serverboard Setup
!
5-5 Installing a Processor and Heatsink
When handling the processor package, avoid placing direct pressure on the label area of the fan.
Notes:
Always connect the power cord last and always remove it before adding, re-
moving or changing any hardware components. Make sure that you install the processor into the CPU socket before you install the CPU heatsink.
If you buy a CPU separately, make sure that you use an Intel-certifi ed multi-
directional heatsink only.
Make sure to install the serverboard into the chassis before you install the CPU
heatsinks.
When receiving a serverboard without a processor pre-installed, make sure that
the plastic CPU socket cap is in place and none of the socket pins are bent; otherwise, contact your retailer immediately.
Refer to the Sup ermi cro web s ite for upd ates on CPU su ppor t.
Installing an LGA1366 Processor
Press the socket clip to release 1. the load plate, which covers the CPU socket, from its locked posi­tion.
Gently lift the socket clip to open 2. the load plate.
Hold the plastic cap at its north 3. and south center edges to remove it from the CPU socket.
Note: The photos on this page and succeeding pages are for illustration purposes only. They do not necessarily refl ect the exact product(s) described in this manual.
Socket Clip Load Plate
Plastic Cap
Holding the north & south edges
5-5
SUPERSERVER 7046T-NTR+ User's Manual
After removing the plastic cap, use 1. your thumb and the index fi nger to hold the CPU at the north and south center edges.
Align the CPU key (the semi-circle 2. cutout) with the socket key (the notch below the gold color dot on the side of the socket).
Once the CPU and the socket are 3. aligned, carefully lower the CPU straight down into the socket. Do not rub the CPU against the surface of the socket or its pins to avoid damaging the CPU or the socket.
With the CPU in the socket, in-4. spect the four corners of the CPU to make sure that it sits level and is properly installed.
CPU
CPU Socket
CPU
Align CPU keys with socket keys.
Once the CPU is securely seated 5. in the socket, lower the CPU load plate to the socket.
Use your thumb to gently push the 6. socket clip down to the clip lock.
Important! Please save the plastic cap. The serverboard must be shipped with the plastic cap properly installed to protect the CPU socket pins. Shipment without the plastic cap properly installed may cause damage to the socket pins.
Load Plate
5-6
Installing a CPU Heatsink
Remove power from the system 1. and unplug the AC power cord from the power supply.
Do not apply any thermal grease 2. to the heatsink or the CPU die; the required amount has already been applied.
Place the heatsink on top of the 3. CPU so that the four mounting holes are aligned with those on the (preinstalled) heatsink reten­tion mechanism.
Chapter 5: Advanced Serverboard Setup
Screw in two diagonal screws (i.e. 4. the #1 and the #2 screws) until just snug. Do not fully tighten the screws or you may damage the CPU.)
Add the two remaining screws 5. then fi nish the installation by fully tightening all four screws.
Removing the Heatsink
1. Unscrew and remove the heatsink screws from the serverboard in the sequence as show in the picture above.
2. Hold the heatsink and gently wriggle the heatsink to loosen it from the CPU. (Do not use excessive force when wriggling the heatsink!!)
3. Once the heatsink is loose, remove it from the CPU socket.
4. Clean the surface of the CPU and the heatsink to get rid of the old thermal grease. Reapply the proper amount of thermal grease on the surface before you re-install a heatsink.
Note: see Chapter 6 for details on installing the air shroud.
5-7
SUPERSERVER 7046T-NTR+ User's Manual
!
5-6 Installing Memory
CAUTION! Exercise extreme care when installing or removing DIMM modules to prevent any possible damage.
Memory Support
The X8DTN+ supports up to 144 GB of DDR3 1333/1066/800 registered ECC SDRAM in 18 DIMM slots. Three-way interleaved memory is supported. For optimal memory performance, install DIMMs three at a time. Use memory modules of the same type and speed. See the following table for memory installation.
DIMM Installation
Installing Memory Modules
Insert the desired number of DIMMs into the memory slots, beginning with 1. DIMM #1A and DIMM #2A, then DIMM #3A and DIMM #4A, etc. (see Memory Confi guration Table below). Always spread DIMMs across all three banks for each CPU (see Figure 5-4).
Insert each DIMM module vertically into its slot. Pay attention to the notch 2. along the bottom of the module to avoid installing incorrectly (see Figure 5-3).
Gently press down on the DIMM module until it snaps into place in the slot. 3. Repeat for all modules.
To Install : Inser t module vert ic ally a nd pre ss down unt il it sn aps in to place. Pay a tte ntio n to the ali gnme nt notc h at the bottom.
To Remove:
Use your thumbs to gently push the release tabs near both ends of the module. This should release it from the slot.
Figure 5-3. DIMM Installation
Notch
Note: Notch should align with the receptive key
Release Tab
point on the slot.
Notch
Front View
Release Tab
Top View of DDR3 Slot
5-8
Chapter 5: Advanced Serverboard Setup
Memory Support
The X8DTN+ supports up to 144 GB Registered ECC DDR3-1333/1066/800 MHz registered ECC SDRAM in 18 DIMM slots. DIMM sizes of 8 GB, 4 GB, 2 GB and 1 GB are supported.
Populating DIMMs
Follow the tables below when installing memory.
Populating DIMMs for Optimal Performance
For One CPU (CPU1) Installed (Populate the CPU1 DIMM slots)
CPU1: Branch 0 CPU1: Branch 1 CPU1: Branch 2
3 DIMMs 1A 2A 3A 6 DIMMs 1A 1B 2A 2B 3A 3B 9 DIMMs 1A 1B 1C 2A 2B 2C 3A 3B 3C
Populating DIMMs for Optimal Performance
For One CPU (CPU2) Installed (Populate the CPU2 DIMM slots)
CPU2: Branch 0 CPU2: Branch 1 CPU2: Branch 2
3 DIMMs 1A 2A 3A 6 DIMMs 1A 1B 2A 2B 3A 3B 9 DIMMs 1A 1B 1C 2A 2B 2C 3A 3B 3C
Populating DIMMs for Optimal Performance
For Two CPUs Installed
CPU1 DIMMs CPU2 DIMMs
Branch 0 Branch 1 Branch 2 Branch 0 Branch 1 Branch 2
6 DIMMs
12 DIMMs
18 DIMMs
1A 2A 3A 1A 2A 3A
1A 1B 2A 2B 3A 3B 1A 1B 2A 2B 3A 3B
1A 1B 1C 2A 2B 2C 3A 3B 3C 1A 1B 1C 2A 2B 2C 3A 3B 3C
Memory Population Table
DIMM Slots per Channel
3 1 Reg. DDR3 ECC 800,1066,1333 SR, DR 3 1 Reg. DDR3 ECC 800,1066, QR 3 2 Reg. DDR3 ECC 800,1066 SR, DR 3 2 Reg. DDR3 ECC 800 SR, DR, QR 3 3 Reg. DDR3 ECC 800 SR, DR
DIMMs Populated per Channel
DIMM Type (Reg.=
Registered)
Speeds (in MHz) Ranks per DIMM
(any combination; SR=Single Rank, DR=Dual Rank, QR=Quad Rank)
5-9
SUPERSERVER 7046T-NTR+ User's Manual
Notes: Due to OS limitations, some operating systems may not show more than 4 GB of memory.
Due to mem o ry all o catio n t o sys te m d evi ces, th e am o u nt of m e m o ry that r e ma i ns available for operational use will be reduced when 4 GB of R AM is used. The reduc tion in m emor y avai labili ty is di spro por tio nal. (See th e Table below.)
Possible System Memory Allocation & Availability
System Device Size Physical Memory Remaining (Available)
Firmware Hub fl ash memory (System BIOS) 1 MB 3.99 GB Local APIC 4 KB 3.99 GB Area Reserved for the chipset 2 MB 3.99 GB I/O APIC (4 Kbytes) 4 KB 3.99 GB PCI Enumeration Area 1 256 MB 3.76 GB PCI Express (256 MB) 256 MB 3.51 GB PCI Enumeration Area 2 (if needed) -Aligned on
256-MB boundary­VGA Memory 16 MB 2.85 GB TSEG 1 MB 2.84 GB Memory available for the OS & other applications 2.84 GB
512 MB 3.01 GB
(4 GB Total System Memory)
5-7 Installing PCI Expansion Cards
The 7046T-NTR+ can accommodate standard size add-on cards installed into all of the slots on the X8DTN+ serverboard.
Installing an Add-on Card
Begin by removing the shield for the PCI slot you wish to populate.1.
Fully seat the card into the slot, pushing down with your thumbs evenly on 2. both sides of the card.
Finish by using a screw to secure the top of the card shield to the chassis. 3. The PCI slot shields protect the serverboard and its components from EMI and aid in proper ventilation, so make sure there is always a shield covering each unused slot.
5-10
5-8 Serverboard Details
Figure 5-4. X8DTN+ Layout
(not drawn to scale)
Chapter 5: Advanced Serverboard Setup
Fan4
Fan6
KB/MS
USB0/1
COM1
VGA
LAN1
LAN2
Fan8 CPU2 Fan
ATI VGA
Controller
X8DTN+
LAN
CTRL
JPL1
S I/O
Bank1
Bank2
Bank3
J21
Slot 6: PCI Express 2.0 x8
JK1
SIMLP IPMI
Slot 5: PCI Express x4
Slot 4: PCI Express 2.0 x8
Slot 3: PCI-X 133/100 MHz
Slot 2: PCI-X 133/100 MHz
Slot 1: PCI-X 133 MHz
Slot 0: PCI-U
CPU2 DIMM3A
CPU2 DIMM3B
CPU2 DIMM3C
CPU2 DIMM2A
CPU2 DIMM2B
CPU2 DIMM2C
CPU2 DIMM1A
CPU2 DIMM1B
CPU2 DIMM1C
CPU2
SEPC
JBT1
JI2C1
JI2C2
Battery
IPMB
Bank3
Bank2
Bank1
COM2
PWR I2C
PXH
USB6
Fan7 CPU1 Fan
IOH-36D
USB7
JPW1
CPU1 DIMM1C
CPU1 DIMM1B
CPU1 DIMM1A
CPU1 DIMM2C
CPU1 DIMM2B
CPU1 DIMM2A
CPU1 DIMM3C
CPU1 DIMM3B
CPU1 DIMM3A
Intel
USB2/3
CPU1
JP1
SPI
BIOS
Intel
ICH10R
JL1
JPW4
I-SATA5
I-SATA4
JPW3
Floppy
T-SGPIO1
I-SATA3
I-SATA2
Fan1
Fan2
Speaker
Fan3
IDE
JWF1
I-SATA1
JF1
LE1
JD1
JOH1
Fan4
T-SGPIO2
JP3
I-SATA0
5-11
SUPERSERVER 7046T-NTR+ User's Manual
X8DTN+ Quick Reference
Jumper Description Default Setting
JBT1 CMOS Clear See Section 5-10 J12 SMB to PCI-Exp. Slots Pins 2-3 (Disabled) J13 SMB to PCI-X Slots Pins 2-3 (Disabled) J21 Watch Dog Enable/Disable Pins 1-2 (Reset) JP3 IDE Enable/Disable Pins 1-2 (Enabled) JPG1 VGA Enable/Disable Pins 1-2 (Enable) JPL1 LAN1/2 Enable/Disable Pins 1-2 (Enabled)
Connector Description
COM1/COM2 COM1/COM2 Serial Port/Header FAN 1-8 System/CPU Fan Headers (Fans 7~8: CPU Fans)
Floppy Floppy Disk Drive Connector
2
IPMB IPMB I
C Connector (for IPMI Card) I-SATA0 ~ I-SATA5 (Intel South Bridge) SATA Ports JAR Alarm Reset JD1 PWR LED/Speaker Header JF1 Front Panel Connector JL1 Chassis Intrusion Header JOH1 Overheat LED Header JPW1 24-pin ATX Main Power Connector JPW3/JPW4 8-pin 12-V Power Connectors JWOL1 Wake-On-LAN Header JWOR1 Wake-On-Ring Header JWF1 Compact Flash Power Connector JK1 Keylock LAN1/2 Gigabit Ethernet (RJ45) Ports
2
PWR I SIMLP (Low Profi le) SIMLP IPMI 2.0 Socket T-SGPIO-1/T-SGPIO-2 Serial General Purpose Input/Output Headers USB0/1 (Back Panel) Universal Serial Bus (USB) Ports
C Power I2C (SMB) Connector
USB 2/3, 4, 6, 7 Front Pa nel Ac ce ssib le US B Hea der s
LED Description
LE1 Onboar d Sta ndby PW R war ning L ED Ind ica tor
5-12
Chapter 5: Advanced Serverboard Setup
5-9 Connector Defi nitions
Main ATX Power Supply Connector
The primary power supply connector (JPW1) meets the SSI (Superset ATX) 24-pin specifi cation. Refer to the table on the right for the pin defi nitions of the ATX 24-pin power connector. You must also connect the 8-pin (JPW3/ JPW4) processor power connectors to your power supply (see below).
Secondary Power Connector
JPW3 must also be connected to the power supply. See the table on the right for pin defi nitions.
ATX Power 24-pin Connector
Pin Defi nitions (JPW1)
Pin# Defi nition Pin # Defi nition 13 +3.3V 1 +3.3V 14 -12V 2 +3.3V 15 COM 3 COM 16 PS_ON 4 +5V 17 COM 5 COM 18 COM 6 +5V 19 COM 7 COM 20 Res (NC) 8 PWR_OK 21 +5V 9 5VSB 22 +5V 10 +12V 23 +5V 11 +12V 24 COM 12 +3.3V
+12V 8-pin Power
Pin Defi nitions (JPW3)
Pins Defi nition 1 - 4 Ground 5 - 8 +12V
Required Connection
Secondary Power Connector
JPW4 must also be connected to the power supply. See the table on the right for pin defi nitions.
Power Button
The Power On connection is on pins 1 and 2 of JF1. These should be connected to the chassis power but­ton. See the table on the right for pin defi nitions.
Reset Button
The Reset Button connection is located on pins 3 and 4 of JF1 and attaches to the reset switch on the computer chassis. See the table on the right for pin defi nitions.
+12V 8-pin Power
Pin Defi nitions (JPW4)
Pins Defi nition 1 - 4 Ground 5 - 8 +12V
Required Connection
Power Button
Pin Defi nitions (JF1)
Pin# Defi nition 1 Power Signal 2 Ground
Reset Button
Pin Defi nitions (JF1)
Pin# Defi nition 3 Reset 4 Ground
5-13
SUPERSERVER 7046T-NTR+ User's Manual
Power Fail LED
The Power Fail LED connection is locate d on pins 5 and 6 of JF1. Re­fer to the table on the right for pin defi nitions.
PWR Fail LED
Pin Defi nitions (JF1)
Pin# Defi nition 5 Vcc 6 Ground
Overheat/Fan Fail LED (OH)
Connect an LED to the OH connection on pins 7 and 8 of JF1 to provide ad­vanced warning of chassis overheat­ing. Refer to the table on the right for pin defi nitions.
NIC2 (JLAN2) LED
The LED connections for JLAN2 are on pins 9 and 10 of JF1. Attach an LED cable to display network activ­ity. See the table on the right for pin defi nitions.
NIC1 (JLAN1) LED
The LED connections for JLAN1 are on pins 11 and 12 of JF1. Attach an LED cable to display network activ­ity. See the table on the right for pin defi nitions.
OH/Fan Fail LED
Pin Defi nitions (JF1)
Pin# Defi nition 7 Vcc 8 Ground
Pin Defi nitions (JF1)
Pin# Defi nition 9 Vcc 10 Ground
Pin Defi nitions (JF1)
Pin# Defi nition 11 Vcc 12 Ground
OH/Fan Fail Indicator
Status
State Defi nition Off Normal On Overheat Flash-
ing
NIC2 LED
NIC1 LED
Fan Fail
HDD LED
The HDD LED connection is located on pins 13 and 14 of JF1. This LED is used to display all IDE and SATA activity. See the table on the right for pin defi nitions.
5-14
HDD LED
Pin Defi nitions (JF1)
Pin# Defi nition 13 Vcc 14 HD Active
Chapter 5: Advanced Serverboard Setup
Power On LED
The Power On LED connector is lo­cated on pins 15 and 16 of JF1 (use JLED for a 3-pin connector). This connection is used to provide LED indication of power being supplied to the system. See the table on the right for pin defi nitions.
NMI Button
The non-maskable interrupt button header is located on pins 19 and 20 of JF1. Refer to the table on the right for pin defi nitions.
Fan Headers
Power LED
Pin Defi nitions (JF1)
Pin# Defi nition 15 5V Stby 16 Control
NMI Button
Pin Defi nitions (JF1)
Pin# Defi nition 19 Control 20 Ground
There are eight fan headers on the serverboard, all of which are 4-pin fans. Pins 1- 3 of the f an hea der s are backward compatible with the tradi­tional 3 -p in fans. (Fan spee d control is supported with 4-pin fans only.) See the table on the right for pin defi - nitio ns. The onb oard fan sp eeds are controlled by Thermal Management (via Hardwa re Monitori ng) under t he Advanced Section in the BIOS. The default is disabled. When using Ther­mal Management setting, please use all 3 -pin f ans or al l 4- pin fa ns.
ATX PS/2 Keyboard and PS/2 Mouse Ports
The ATX PS/2 keyboard and the PS/2 mouse are located beside the USB0/1 ports. The mouse port is above the keyboard port. See the table on the right for pin defi nitions.
Fan Header
Pin Defi nitions
(FAN1-8)
Pin# Defi nition 1 Ground (Black) 2 +12V (Red) 3 Tachometer 4 PWM Control
Note: Fan 7 is for the CPU1 and Fan8 is for the CPU2 heatsink.
PS/2 Keyboard and
Mouse Port Pin
Defi nitions (J28)
Pin# Defi nition 1 Data 2NC 3 Ground 4 VCC 5 Clock 6NC
5-15
SUPERSERVER 7046T-NTR+ User's Manual
Chassis Intrusion
The Chassis Intrusion header is des­ignated JL1. Attach an appropriate cable from the chassis to inform you of a chassis intrusion when the chas­sis is opened
Wake-On-LAN
The Wake-On-LAN header is des­ignated JWOL1 on the serverboard. See the table on the right for pin defi nitions. You must also have a LAN card with a Wake-On-LAN connector and cable to use this feature.
Chassis Intrusion
Pin Defi nitions (JL1)
Pin# Defi nition 1 Intrusion Input 2 Ground
Wake-On-LAN
Pin Defi nitions
(JWOL1)
Pin# Defi nition 1 +5V Standby 2 Ground 3 Wake-up
Wake-On-Ring
The Wake-On-Ring header is desig­nated JWOR1. This function allows your computer to receive and be "awakened" by an incoming call when in the suspend state. See the table on the right for pin defi nitions. You must also have a WOR card and cable to use this feature.
LAN1/2 (Ethernet Ports)
Two Ethernet ports (designated LAN1 and LAN2) are located beside the VGA port on the I/O backplane. These ports accept RJ45 type cables.
Wake-On-Ring Pin Defi nitions
(JWOR1)
Pin# Defi nition 1 Ground (Black) 2 Wake-up
5-16
Chapter 5: Advanced Serverboard Setup
Serial Ports
Two serial ports are included on the serverboard. COM1 is a backpanel port and COM2 is a header located near the JWOL header. See the table on the right for pin defi nitions.
Power LED/Speaker
On JD1 header, pins 1-3 are for a power LED and pins 4-7 are for the speaker. Close pins 4-7 with a jumper to use an external speaker. If you wish to use the onboard speaker, please close pins 6-7. See the table on the right for speaker pin defi nitions.
Serial Port Pin Defi nitions
(COM1/COM2)
Pin # Defi nition Pin # Defi nition 1 DCD 6 DSR 2 RXD 7 RTS 3 TXD 8 CTS 4 DTR 9 RI 5 Ground 10 NC
Power LED/Speaker
Connector (JD1)
Pin Setting Defi nition Pins 6-7 Internal Speaker Pins 4-7 External Speaker
Universal Serial Bus (USB)
There are two Universal Serial Bus ports located on the I/O panel and fi ve additional USB headers located on the serverboard. The headers can be used to provide front side USB access (cables not included). See the table on the right for pin defi nitions.
SGPIO Headers
The SGPIO (Serial General Purpose Input/Output) headers are used to communicate with the enclosure management chip on the backplane. See the table on the right for pin defi nitions.
Universal Serial Bus
Pin Defi nitions (USB)
USB0/1
Pin # Defi nition 1 +5V 1 +5V 2 PO- 2 PO­3 PO+ 3 PO+ 4 Ground 4 Ground 5 N/A 5 Key
SGPIO Header
Pin Defi nitions (T-SGPIO-1/T-SGPIO-2)
Pin# Defi nition Pin Defi nition 1 NC 2 *NC 3 Ground 4 DATA Out
5 Load 6 Ground 7 Clock 8 *NC
USB2/3/4/6/7
Pin # Defi nition
5-17
NC = No Connection
SUPERSERVER 7046T-NTR+ User's Manual
Alarm Reset
If three power supplies are installed, the system can notify you when any of the three power modules fail. Connect JAR to a micro-switch to enable you to turn off the alarm that is activated when a power module fails. See the table on the right for pin defi nitions.
Power I2C Connector
The power System Management Bus
2
(I
C) connector monitors the status of the power supply, fan and system temperature. See the table on the right for pin defi nitions.
Alarm Reset Header
Pin Defi nitions (JAR)
Pin Setting Defi nition Pin 1 Ground Pin 2 +5V
PWR I2C Connector
Pin Defi nitions (PWR I2C)
Pin# Defi nition 1 Clock 2 Data
3 PWR Fail (Input from PS to MB) 4 Ground 5 +3.3V
IPMB Connector
A connector for the IPMI (Intelligent Platform Management Interface) slot is designated IPMB. Connect the appropriate cable here to utilize this management feature on your system.
Overheat LED/Fan Fail (JOH1)
The JOH1 header is used to connect an LED to provide warning of chassis overheating or fan failure. This LED will blink to indicate a fan failure. Refer to the tables on right for LED status and pin defi nitions.
Pin Defi nitions (IPMB)
Pin# Defi nition 1 Data 2 Ground 3 Clock 4 No Connection
OH/Fan Fail LED
States
State Message Solid Overheat Blinking Fan Fail
IPMB Connector
Overheat LED
Pin Defi nitions (JOH1)
Pin# Defi nition 1 5vDC 2 OH Active
5-18
Chapter 5: Advanced Serverboard Setup
Keylock
The keyboard lock connection is designated JK1. Utilizing this header allows you to inhibit any actions made on the keyboard, effectively "locking" it.
Compact Flash Card PWR Connector
A Compact Flash Card Power Con­nector is located at JWF1. For the Compact Flash Card to work properly , you will need to enable with JCF1 and connect a Compact Flash Card power cable to JWF1 fi rst.
Keylock
Pin Defi nitions (JK1)
Pin# Defi nition 1 Ground 2 Keylock R-N
Compact Flash Card PWR
Connector (JWF1)
Jumper Defi nition On Compact Flash
Power On
Off Compact Flash
Power Off
5-10 Jumper Settings
Explanation of Jumpers
To modify the operation of the serverboard, jumpers can be used to choose between optional settings. Jumpers create shorts between two pins to change the function of the con­nector. Pin 1 is identifi ed with a square solder pad on the printed circuit board. See the serverboard layout pages for jumper locations.
Note: On a two-pin jumper, "Closed" means the jumper is on both pins and "Open" means the jumper is either on only one pin or completely removed.
3 2 1
Connector
Pins
Jumper
3 2 1
Setting
5-19
SUPERSERVER 7046T-NTR+ User's Manual
CMOS Clear
JBT1 is used to clear CMOS (which will also clear any passwords). Instead of pins, this jumper consists of contact pads to prevent accidentally clearing the contents of CMOS.
To clear CMOS,
First power down the system and unplug the power cord(s).1.
With the power disconnected, short the CMOS pads with a metal object such 2. as a small screwdriver.
Remove the screwdriver (or shorting device).3.
Reconnect the power cord(s) and power on the system.4.
Note: Do not use the PW_ON connector to clear CMOS.
VGA Enable/Disable
JPG1 allows you to enable or disable the VGA port. The default position is on pins 1 and 2 to enable VGA. See the table on the right for jumper settings.
LAN1/2 Enable/Disable
Change the setting of jumper JPL1 to enable or disable the LAN1/LAN2 Eth­ernets port on the serverboard. See the table on the right for jumper settings. The default setting is enabled.
VGA Enable/Disable
Jumper Settings (JPG1)
Jumper Setting Defi nition Pins 1-2 Enabled Pins 2-3 Disabled
LAN1/2 Enable/Disable
Jumper Settings (JPL1)
Jumper Setting Defi nition Pins 1-2 Enabled Pins 2-3 Disabled
5-20
Watch Dog Enable/Disable
Jumper J21 controls the Watch Dog function. Watch Dog is a system moni­tor that can reboot the system when a software application hangs. Jumping pins 1-2 will cause WD to reset the system if an application hangs. Jumping pins 2-3 will generate a non-maskable interrupt signal for the application that hangs. See the table on the right for jumper settings. Watch Dog must also be enabled in BIOS.
Note: When enabled, the user needs to write their own application software in order to disable the Watch Dog Timer.
Chapter 5: Advanced Serverboard Setup
Watch Dog
Jumper Settings (J21)
Jumper Setting Defi nition Pins 1-2 Reset Pins 2-3 NMI Open Disabled
IDE Enable/Disable
Jumper JP3 allows you to enable or disable the onboard IDE connector. The default setting is Pins 1-2 to enable the connection. See the table on the right for jumper settings.
I2C Bus to PCI-X/PCI-Exp. Slots
Jumpers J12 and J13 allow you to con­nect the System Management Bus (I
2
C) to the PCI slots. The default setting is Open (Disabled.) Both jumpers must be set to the same setting See the table on the right for jumper settings.
IDE Enable
Jumper Settings
Jumper Defi nition 1-2 IDE Enable 2-3 IDE Disable
I2C to PCI-X/PCI-E Slots
Jumper Settings (J12/J13)
Jumper Setting Defi nition
2
JI
C1: Closed JI2C2:Closed Enabled
2
JI
C1: Open JI2C2: Open Disabled
5-21
SUPERSERVER 7046T-NTR+ User's Manual
5-11 Onboard Indicators
LAN1/2 LEDs
The Ethernet ports (located beside the VGA port) have two LEDs. On each port, the yellow LED fl ashes to indi- cate activity while the other LED may be green, amber or off to indicate the speed of the connection. See the table on the right for the functions associ­ated with the connection speed LED.
Onboard Power LED (LE1)
An Onboard Power LED is located at LE1. This LED Indicator is lit when the system is on. Be sure to unplug the power cable before removing or adding any components. See the table on the right for more details.
Activity LED Link LED
(Connection Speed Indicator)
LED Color Defi nition Off NC or 10 Mb/s Green 100 Mb/s Amber 1 Gb/s
Onboard PWR LED Indicator
LED Color Defi nition Off System Off (PWR cable
Green System On Green:
Flashing Quickly
Green: Flashing Slowly
GLAN1/2 LED
(LE1)
not connected)
ACPI S1 State
ACPI S3 (STR) State
5-22
Chapter 5: Advanced Serverboard Setup
5-12 Floppy, IDE and SATA Ports
Use the following information to connect the IDE hard disk drive cables.
A red mark on a wire typically designates the location of pin 1.
The 80-wire ATA100/66 IDE hard disk drive cable that came with your system has two connectors to support two drives. This special cable should be used to take advantage of the speed this new technology offers. The blue connector connects to the onboard IDE connector interface and the other connector(s) to your hard drive(s). Consult the documentation that came with your disk drive for details on actual jumper locations and settings for the hard disk drive.
Floppy Drive Connector
The fl oppy connector is located be- side the IDE connector. See the table below for pin defi nitions.
Floppy Drive Connector
Pin Defi nitions (Floppy)
Pin# Defi nition Pin # Defi nition 1 Ground 2 FDHDIN 3 Ground 4 Reserved 5 Key 6 FDEDIN 7 Ground 8 Index 9 Ground 10 Motor Enable 11 Ground 12 Drive Select B 13 Ground 14 Drive Select B 15 Ground 16 Motor Enable 17 Ground 18 DIR 19 Ground 20 STEP 21 Ground 22 Write Data 23 Ground 24 Write Gate 25 Ground 26 Track 00 27 Ground 28 Write Protect 29 Ground 30 Read Data 31 Ground 32 Side 1 Select 33 Ground 34 Diskette
5-23
SUPERSERVER 7046T-NTR+ User's Manual
IDE Connector
There is a single IDE connector on the serverboard. The IDE connector may be used for a Compact Flash Card. (See the note below.) See the table on the right for pin defi nitions.
Note: If populated with a Compact Flash Card, the IDE connector will be available for one device only. For the Compact Flash Card to work properly , you will need to connect a power cable to JWF1 fi rst.
IDE Drive Connector
Pin Defi nitions (IDE)
Pin# Defi nition Pin # Defi nition 1 Reset IDE 2 Ground 3 Host Data 7 4 Host Data 8 5 Host Data 6 6 Host Data 9 7 Host Data 5 8 Host Data 10 9 Host Data 4 10 Host Data 11 11 Host Data 3 12 Host Data 12 13 Host Data 2 14 Host Data 13 15 Host Data 1 16 Host Data 14 17 Host Data 0 18 Host Data 15 19 Ground 20 Key 21 DRQ3 22 Ground 23 I/O Write 24 Ground 25 I/O Read 26 Ground 27 IOCHRDY 28 BALE 29 DACK3 30 Ground 31 IRQ14 32 IOCS16 33 Addr1 34 Ground 35 Addr0 36 Addr2 37 Chip Select 0 38 Chip Select 1 39 Activity 40 Ground
SATA Ports
There are no jumpers to confi gure the onboard SATA connectors. See the table on the right for pin defi nitions.
5-24
Pin Defi nitions (I-SATA0~I-SATA5)
SATA Port
Pin # Defi nition 1 Ground 2 TXP 3 TXN 4 Ground 5 RXN 6 RXP 7 Ground
Chapter 5: Advanced Serverboard Setup
5-13 Installing Software
After the hardware has been installed, you should fi rst install the operating system and then the drivers. The necessary drivers are all included on the Supermicro CDs that came packaged with your motherboard.
Driver/Tool Installation Display Screen
Note: Click the icons showing a hand writing on paper to view the readme les
for each item. Click the computer icons to the right of these items to install each item (from top to the bottom) one at a time. After installing each item, you must re-boot the system before moving on to the next item on the list. The bottom icon with a CD on it allows you to view the entire contents of the CD.
5-25
SUPERSERVER 7046T-NTR+ User's Manual
Supero Doctor III
The Supero Doctor III program is a Web based management tool that supports remote management capability. It includes Remote and Local Management tools. The local management is called SD III Client. The Supero Doctor III program in­cluded on the CD-ROM that came with your motherboard allows you to monitor the environment and operations of your system. Supero Doctor III displays crucial system information such as CPU temperature, system voltages and fan status. See the Figure below for a display of the Supero Doctor III interface.
Note: The default User Name and Password for SuperDoctor III is ADMIN / AD­MIN.
Note: When SuperDoctor III is fi rst installed, it adopts the temperature threshold settings that have been set in BIOS. Any subsequent changes to these thresholds must be made within Super Doctor, as the Super Doctor settings override the BIOS settings. To set the BIOS temperature threshold settings again, you would fi rst need to uninstall SuperDoctor III.
Supero Doctor III Interface Display Screen (Health Information)
5-26
Chapter 5: Advanced Serverboard Setup
Supero Doctor III Interface Display Screen (Remote Control)
Note: SD III Software Revision 1.0 can be downloaded from our Web Site at: ftp://ftp. supermicro.com/utility/Supero_Doctor_III/. You can also download the SDIII User's Guide at: <http://www.supermicro.com/PRODUCT/Manuals/SDIII/UserGuide.pdf>. For Linux, we will recommend using Supero Doctor II.
5-27
SUPERSERVER 7046T-NTR+ User's Manual
Notes
5-28
Chapter 6: Advanced Chassis Setup
Chapter 6
Advanced Chassis Setup
This chapter covers the steps required to install components and perform simple maintenance on the SC745TQ-R800B chassis. Following the component installation steps in the order given will eliminate most common problems. If some steps are unnecessary, skip ahead to the step that follows. Refer to Chapter 2 for instructions on installing the system as a 4U rackmount.
Tools Required
: The only tool you will need is a Philips screwdriver.
6-1 Static-Sensitive Devices
Static electrical discharge can damage electronic com ponents. To prevent damage to any printed circuit boards (PCBs), it is important to handle them very carefully. The following measures are generally suffi cient to protect your equipment from static discharge.
Precautions
Use a grounded wrist strap designed to prevent static discharge.
Touch a grounded metal object before removing any board from its antistatic bag.
Handle a board by its edges only; do not touch its components, peripheral chips,
memory modules or gold contacts.
When handling chips or modules, avoid touching their pins.
Put the serverboard, add-on cards and peripherals back into their antistatic bags when not in use.
For grounding purposes, make sure your computer chassis provides excellent
conductivity between the power supply, the case, the mounting fasteners and the serverboard.
Unpacking
The serverboard is shipped in antistatic packaging. When unpacking the board, make sure the person handling it is static protected.
6-1
SUPERSERVER 7046T-NTR+ User's Manual
Figure 6-1. Chassis Front View
5.25" Drive Bays (2)
System ResetMain Power
USB Ports
6-2
8 SATA Drive Bays (behind locking bezel)
Chapter 6: Advanced Chassis Setup
6-2 Front Control Panel
The front control panel must be connected to the JF1 connector on the serverboard to provide you with system status and alarm indications. A ribbon cable has bundled these wires together to simplify this connection. Connect the cable from JF1 on the serverboard (making sure the red wire plugs into pin 1) to the appropriate comnnec­tor on the front control panel PCB (printed circuit board). Pull all excess cabling over to the control panel side of the chassis. The LEDs on the control panel inform you of system status - see Figure 6-2 for details. See Chapter 5 for details on JF1.
Figure 6-2. Front Control Panel LEDs
Power
HDD
NIC1
NIC2
Overheat/Fan Fail
Power Fail
Indicates power is being supplied to the system.
Indicates IDE device and hard drive activity. On the SC745TQ-R800B, this LED indicates SATA hard drive activity when fl ashing.
1
Indicates network activity on LAN port 1.
2
Indicates network activity on LAN port 2
When this LED fl ashes, it indicates a fan failure. When on continuously it indicates an overheat condition (see Chapter 3 for details).
Indicates a power supply failure.
6-3
SUPERSERVER 7046T-NTR+ User's Manual
6-3 System Fans
Three 8-cm chassis cooling fans (located in the center of the chassis) provide cool­ing airfl ow while two 8-cm exhaust fans expel hot air from the chassis. The chassis is also fi tted with an air shroud to concentrate the fl ow of cooling air over the areas of highest generated heat. The fans should all be connected to headers on the serverboard (see Chapter 5). Each power supply module also has a cooling fan.
Fan Failure
Under normal operation, all three chassis fans, both exhaust fans and the power supply fans run continuously. The chassis fans and the exhaust fans are hot-swap­pable and can be replaced without powering down the system.
Replacing Chassis Cooling Fans
First, remove the top/left chassis cover (see Chapter 2 for details on removing 1. the cover) to locate the fan that has stopped working.
Depress the locking tab on the failed fan: on a chassis fan, push the tab on 2. the side of the housing inward, on the exhaust fan push down on the colored tab. With the tab depressed, pull the unit straight out (see Figure 6-3). The wiring for these fans has been designed to detach automatically.
Replace the failed fan with an identical one. Install it in the same position 3. and orientation as the one you removed; it should click into place when fully inserted. Check that the fan is working then replace the top/left side chassis panel.
Removing the Air Shroud
Under most circumstances you will not need to remove the air shroud to perform any service on the system. However, if you wish to temporarily remove it (the air shroud should always be in place when the system is operating), please follow this procedure.
Begin by depressing the tabs at the front and rear of the shroud to unlock it.1.
Lift the air shroud up and out of the chassis (see Figure 6-4).2.
To reinstall, simply position the air shroud in its proper place and push it in 3. until you hear it click.
6-4
Chapter 6: Advanced Chassis Setup
Figure 6-3. Removing a Chassis Fan
Figure 6-4. Removing the Air Shroud
6-5
SUPERSERVER 7046T-NTR+ User's Manual
!
6-4 Drive Bay Installation
SATA Drives
A total of six SATA drives may be housed in the SC745TQ-R800B chassis. The drive IDs are preconfi gured as 0 through 5 in order from bottom to top (or from left to right if rackmounted). A bezel covers the drive area but does not need to be removed to access the drives; simply swing open the bezel. If you wish to remove the bezel piece, push on the three tabs on the inside of the left lip of the front chassis cover. Then slightly swing out the same (left) side of the cover - about ½ inch only . Remove by pushing on the open side of the cover to remove it from the chassis (do not try to swing or pull it straight out after opening the left side).
The SATA drives are mounted in drive carriers to simplify their installation and removal from the chassis. These drives are hot-swappable, meaning they can be removed and installed without powering down the system. The carriers also work to promote proper airfl ow for the system. For this reason, even carriers without SATA drives must remain in the server.
Regardless of how many SA TA drives are installed, all drive carri­ers must remain in the drive bays to promote proper airfl ow.
Installing/Removing SATA Drives
To remove a carrier, fi rst open the front bezel.1.
Push the release button located beside the drive LEDs (See Figure 6-5).2.
Swing the handle fully out and then use it to pull the unit straight out.3.
Note: Your operating system must have RAID support to enable the hot-swap capability of the SATA drives.
Mounting a SATA Drive in a Drive Carrier
Insert the drive into the carrier with the printed circuit board side facing down 1. so that the mounting holes align with those in the carrier.
Secure the drive to the carrier with four screws (see Figure 6-6).2.
6-6
Chapter 6: Advanced Chassis Setup
!
Figure 6-5. Removing a SATA Drive Carrier
Figure 6-6. Mounting a SATA Drive in a Carrier
Important! Use extreme caution when working around the SATA backplane. Do not touch the backplane with any metal objects and make sure no cables touch the backplane or obstruct the airfl ow holes.
SATA Backplane
The SA TA drives plug into a SATA backplane. Six data cables (CBL-0061L) and two SATA LED cables (CBL-0157L) need to be connected from the serverboard to the appropriate connectors on the backplane to support SATA six drives. You cannot cascade the SATA backplane.
6-7
SUPERSERVER 7046T-NTR+ User's Manual
Installing Components in the 5.25" Drive Bays
The 7046T-NTR+ has two 5.25" drive bays. Components such as an extra fl oppy drive, IDE hard drives or CD-ROM drives can be installed into these 5.25" drive bays.
First power down the system and then remove the top/left chassis cover to 1. access the drive components.
With the cover off, remove the two or four screws that secure the drive carrier 2. to the chassis (one side only) then push the entire empty drive carrier out from the back.
Adding a DVD-ROM Drive
Remove the guide plates (one on each side) from the empty drive carrier and 1. screw them into both sides of the DVD-ROM drive using the holes provided.
Slide the DVD-ROM into the bay and secure it to the chassis with the drive 2. carrier screws you fi rst removed.
Attach the power and data cables to the drive.3.
Replace the top/left chassis cover before restoring power to the system.4.
Adding an IDE or Floppy Drive
Install one of these drives into one of the removed empty drive carriers 1. with the printed circuit board side toward the carrier so that the drive's mounting holes align with those in the carrier.
Secure the drive to the carrier with four screws then slide the assembly into 2. the bay and secure it to the chassis with the drive carrier screws you fi rst removed.
Attach the power and data cables to the drive.3.
Replace the top/left chassis cover before restoring power to the system.4.
Note: A red wire typically designates the location of pin 1. You should keep the drive carriers inserted in any unused drive bays to reduce EMI and noise and to facilitate the airfl ow inside the chassis.
6-8
Chapter 6: Advanced Chassis Setup
Storage Module
If the 7046T-NTR+ is to be used in a rack confi guration, you must turn the storage module 90 degrees. This can be done before, during, or after setup.
Rotating the Storage Module
Open the chassis cover.1.
Disconnect any cables from the storage module to any components in the 2. chassis.
Push the storage module release lever to unlock the storage module.3.
Grasp the external edges of the storage module and pull it from the chassis.4.
Turn the storage module 90 degrees (as illustrated).5.
Reinsert the module into the chassis and reconnect the cords.6.
Storage Module
Figure 6-7. Rotating the Storage Module
Storage Module
Release Lever
6-9
SUPERSERVER 7046T-NTR+ User's Manual
Adding Drives to the Storage Module
The storage module includes three full sized drive bays and the front LED panel. The storage module can be set up one of three ways:
Add up to three extra hard drives to the drive trays (see page 6-8).
Add up to three peripheral drives (CD-ROM, DVD-ROM, etc.) to the drive trays (see page 6-8).
Add fi ve hot swappable hard drives to the storage module. This confi guration
requires a mobile rack. See procedure below.
Using a Mobile Rack
The SC745TQ-R800B chassis accepts a CSE-M35T-1/CSE-M35TQ mobile rack to install extra hot swappable hard drives. The mobile rack goes into the storage module, which goes into the chassis.
Open the chassis cover.1.
Locate the drive release tabs.2.
Pull the fi rst drive release tab and push the drive tray toward the front of the 3. chassis. Repeat this for all three tabs.
Remove the hard drive tray rails from the hard drive tray. To do this, you must 4. remove two screws from each side. Do this for all three hard drive trays.
Attach the rails to a DVD-ROM, CD-ROM, fl oppy drive, or other peripheral 5. drive. The rails should fi t any standard sized peripherals.
Install all six hard drive rails to the mobile rack. Each individual rail requires 6. two screws. Also, make sure the arrow on the rail points toward the front of the chassis.
Slide the mobile rack into the storage module and chassis.7.
For more information on mobile rack installation and use, refer to SC745 chassis manual (available for download on our web site).
6-10
Chapter 6: Advanced Chassis Setup
Figure 6-8. Adding Drives to the Mobile Rack
6-5 Power Supply
The SuperServer 7046T-NTR+ has a redundant 800 watt power supply consisting of two power modules. Each power supply module has an auto-switching capabil­ity, which enables it to automatically sense and operate at a 100V - 240V input voltage.
Power Supply Failure
If either of the two power supply modules fail, the other module will take the full load and allow the system to continue operation without interruption. The PWR Fail LED will illuminate and remain on until the failed unit has been replaced. Replacement units can be ordered directly from Supermicro (see contact information in the Pref­ace). The hot-swap capability of the power supply modules allows you to replace the failed module without powering down the system.
Removing/Replacing the Power Supply
You do not need to shut down the system to replace a power supply unit. The redundant feature will keep the system up and running while you replace the failed hot-swap unit. Replace with the same model (see Appendix).
Removing the Power Supply
First unplug the power cord from the failed power supply unit.1.
Depress the locking tab on the power supply unit and pull the unit straight out 2. by the handle.
6-11
SUPERSERVER 7046T-NTR+ User's Manual
Installing a New Power Supply
Replace the failed module with another power supply module (must be the 1. exact same model).
Push the new power supply unit into the power bay until you hear a click.2.
Finish by plugging the AC power cord back into the unit. 3.
6-12
Chapter 7: BIOS
Chapter 7
BIOS
7-1 Introduction
This chapter describes the AMI BIOS Setup Utility for the X8DTN+. The AMI ROM BIOS is stored in a Flash EEPROM and can be easily updated. This chapter de­scribes the basic navigation of the AMI BIOS Setup Utility setup screens.
Starting BIOS Setup Utility
To enter the AMI BIOS Setup Utility screens, press the <Delete> key while the system is booting up.
Note: In most cases, the <Delete> key is used to invoke the AMI BIOS setup screen. There are a few cases when other keys are used, such as <F1>, <F2>, etc.
Each main BIOS menu option is described in this manual. The Main BIOS setup menu screen has two main frames. The left frame displays all the options that can be confi gured. Grayed-out options cannot be confi gured. Options in blue can be confi gured by the user. The right frame displays the key legend. Above the key legend is an area reserved for a text message. When an option is selected in the left frame, it is highlighted in white. Often a text message will accompany it. (Note: the AMI BIOS has default text messages built in. Supermicro retains the option to include, omit, or change any of these text messages.)
The AMI BIOS Setup Utility uses a key-based navigation system called "hot keys". Most of the AMI BIOS setup utility "hot keys" can be used at any time during the setup navigation process. These keys include <F1>, <F10>, <Enter>, <ESC>, ar­row keys, etc.
Note: Options printed in Bold are default settings.
How To Change the Confi guration Data
The confi guration data that determines the system parameters may be changed by entering the AMI BIOS Setup utility. This Setup utility can be accessed by pressing <Del> at the appropriate time during system boot.
7-1
SUPERSERVER 7046T-NTR+ User's Manual
!
Starting the Setup Utility
Normally, the only visible Power-On Self-Test (POST) routine is the memory test. As the memory is being tested, press the <Delete> key to enter the main menu of the AMI BIOS Setup Utility. From the main menu, you can access the other setup screens. An AMI BIOS identifi cation string is displayed at the left bottom corner of the screen below the copyright message.
Warning! Do not upgrade the BIOS unless your system has a BIOS-related issue. Flashing the wrong BIOS can cause irreparable damage to the system. In no event shall Supermicro be liable for direct, indirect, special, incidental, or consequential damages arising from a BIOS update. If you have to update the BIOS, do not shut down or reset the system while the BIOS is updating. This is to avoid possible boot failure.
7-2 Main Setup
When you fi rst enter the AMI BIOS Setup Utility , you will enter the Main setup screen. You can always return to the Main setup screen by selecting the Main tab on the top of the screen. The Main BIOS Setup screen is shown below.
System Overview: The following BIOS information will be displayed:
System Time/System Date
Use this option to change the system time and date. Highlight System Time or Sys­tem Date using the arrow keys. Key in new values through the keyboard and press
<Enter>. Press the <Tab> key to move between fi elds. The date must be entered in Day MM/DD/YY format. The time is entered in HH:MM:SS format. (Note: The time is in the 24-hour format. For example, 5:30 P.M. appears as 17:30:00.)
7-2
Chapter 7: BIOS
Supermicro X8DTN+
BIOS Build Version
: This item displays the BIOS revision used in your sys-
tem.
BIOS Build Date
: This item displays the date when this BIOS was completed.
: This item displays the revision number of the AMI
AMI BIOS Core Version
BIOS Core upon which your BIOS was built.
Processor
The AMI BIOS will automatically display the status of the processor used in your system:
CPU Type
: This item displays the type of CPU used in the motherboard.
Speed
: This item displays the speed of the CPU detected by the BIOS.
Physical Count
: This item displays the number of processors installed in your
system as detected by the BIOS.
Logical Count
: This item displays the number of CPU Cores installed in your
system as detected by the BIOS.
Micro_code Revision
: This item displays the revision number of the BIOS
Micro_code used in your system.
System Memory
This displays the size of memory available in the system:
Size
: This item displays the memory size detected by the BIOS.
7-3
SUPERSERVER 7046T-NTR+ User's Manual
7-3 Advanced Setup Confi gurations
Use the arrow keys to select Boot Setup and hit <Enter> to access the submenu items:
XBOOT Features
Quick Boot
If Enabled, this option will skip certain tests during POST to reduce the time needed for system boot. The options are Enabled and Disabled.
Quiet Boot
This option allows the bootup screen options to be modifi ed between POST mes- sages or the OEM logo. Select Disabled to display the POST messages. Select Enabled to display the OEM logo instead of the normal POST messages. The op­tions are Enabled and Disabled.
AddOn ROM Display Mode
This sets the display mode for Option ROM. The options are Force BIOS and Keep Current.
Bootup Num-Lock
This feature selects the Power-on state for Numlock key. The options are Off and On.
Wait For 'F1' If Error
This for ce s the sys tem to wai t until t he ' F1' key is pressed i f an er ror o cc urs . The option s are Dis able d and Enabled.
7-4
Chapter 7: BIOS
Hit 'Del' Message Display
This feature displays "Press DEL to run Setup" during POST. The options are
Enabled and Disabled.
Interrupt 19 Capture
Interrupt 19 is the software interrupt that handles the boot disk function. When this item is set to Enabled, the ROM BIOS of the host adaptors will "capture" Interrupt 19 at boot and allow the drives that are attached to these host adaptors to function as bootable disks. If this item is set to Disabled, the ROM BIOS of the host adap­tors will not capture Interrupt 19, and the drives attached to these adaptors will not function as bootable devices. The options are Enabled and Disabled.
Power Confi guration
Power Button Function
If set to Instant_Off, the system will power off immediately as soon as the user hits the power button. If set to 4_Second_Override, the system will power off when the user presses the power button for 4 seconds or longer. The options are Instant_Off and 4_Second_Override.
Restore on AC Power Loss
Use this feature to set the power state after a power outage. Select Power-Off for the system power to remain off after a power loss. Select Power-On for the system power to be turned on after a power loss. Select Last State to allow the system to resume its last state before a power loss. The options are Power-On, Power-Off and Last State.
Watch Dog Timer
If enable d, the Watch Do g Timer wi l l a l l o w the system to re boot when i t i s i n a ctive for more t han 5 minu tes. The o ption s are Enabl ed and Disabled.
XProcessor and Clock Options
This submenu allows the user to confi gure the Processor and Clock settings.
Ratio CMOS Setting
This option allows the user to set the ratio between the CPU Core Clock and the FSB Frequency. (Note: if an invalid ratio is entered, the AMI BIOS will restore the setting to the previous state.) The default setting depends on the type of CPU installed on the motherboard. The default setting for the CPU installed in your motherboard is [21]. Press "+" or "-" on your keyboard to change this value.
7-5
SUPERSERVER 7046T-NTR+ User's Manual
C1E Support
Select Enabled to use the feature of Enhanced Halt State. C1E signifi cantly reduces the CPU's power consumption by reducing the CPU's clock cycle and voltage during a "Halt State." The options are Disabled and Enabled.
Hardware Prefetcher (Available when supported by the CPU)
If set to Enabled, the hardware pre fetcher will pre fetch streams of data and instruc­tions from the main memory to the L2 cache in the forward or backward manner to improve CPU performance. The options are Disabled and Enabled.
Adjacent Cache Line Prefetch (Available when supported by the CPU)
The CPU fetches the cache line for 64 bytes if this option is set to Disabled. The CPU fetches both cache lines for 128 bytes as comprised if Enabled.
Intel® Virtualization Technology (Available when supported by the CPU)
Select Enabled to use the feature of Virtualization Technology to allow one platform to run multiple operating systems and applications in independent partitions, creat­ing mult iple " vi r tu al" sy stems i n one p hysic al c o mput er. The opti ons ar e Enabled and Dis abled. Not e: If there is any change to this setting, you will need to power off an d restart th e sy s t e m for the c h ange to take effec t. Please r e f er to Intel’s web site for detailed information.
Execute-Disable Bit Capability (Available when supported by the OS and the CPU)
Set to Enabled to enable the Execute Disable Bit which will allow the processor to designate areas in the system memory where an application code can execute and where it cannot, thus preventing a worm or a virus from fl ooding illegal codes to overwhelm the processor or damage the system during an attack. The default is
Enabled. (Refer to Intel and Microsoft Web Sites for more information.)
Simultaneous Multi-Threading (Available when supported by the CPU)
Set to Enabled to use the Simultaneous Multi-Threading Technology, which will result in increased CPU performance. The options are Disabled and Enabled.
Active Processor Cores
Set to Enabled to use a processor's Second Core and beyond. (Please refer to Intel's web site for more information.) The options are All, 1 and 2.
Intel® EIST Technology
EIST (Enhanced Intel SpeedStep Technology) allows the system to automatically adjust processor voltage and core frequency in an effort to reduce power consump-
7-6
Chapter 7: BIOS
tion and heat dissipation. Please refer to Intel’s web site for detailed information. The options are Disable (Disable GV3) and Enable (Enable GV3).
Intel® TurboMode Technology (Available when Intel® EIST Technology is enabled)
Select Enabled to use the Turbo Mode to boost system performance. The options are Enabled and Disabled.
Intel® C-STATE Tech
If enabled, C-State is set by the system automatically to either C2, C3 or C4 state. The options are Disabled and Enabled.
C-State package limit setting (Available when Intel® C-State Tech is enabled)
If set to Auto, the AMI BIOS will automatically set the limit on the C-State package register. The options are Auto, C1, C3, C6 and C7.
C1 Auto Demotion
When enabled, the CPU will conditionally demote C3, C6 or C7 requests to C1 based on un-core auto-demote information. The options are Disabled and Enabled.
C3 Auto Demotion
When enabled, the CPU will conditionally demote C6 or C7 requests to C3 based on un-core auto-demote information. The options are Disabled and Enabled.
Clock Spread Spectrum
Select Enable to use the feature of Clock Spectrum, which will allow the BIOS to monitor and attempt to reduce the level of Electromagnetic Interference caused by the components whenever needed. The options are Disabled and Enabled.
XAdvanced Chipset Control
The items included in the Advanced Settings submenu are listed below:
XCPU Bridge Confi guration
QPI Links Speed
This feature selects QPI's data transfer speed. The options are Slow-mode, and
Full Speed. QPI Frequency
This selects the desired QPI frequency. The options are Auto, 4.800 GT,
5.866GT, 6.400 GT.
7-7
SUPERSERVER 7046T-NTR+ User's Manual
QPI L0s and L1
This enables the QPI power state to low power. L0s and L1 are automatically selected by the motherboard. The options are Disabled and Enabled.
Memory Frequency
This feature forces a DDR3 frequency slower than what the system has detected. The available options are Auto, Force DDR-800, Force DDR-1066, and Force DDR-1333.
Memory Mode
The options are Independent, Channel Mirror, Lockstep and Sparing. Independent - All DIMMs are available to the operating system. Channel Mirror - The motherboard maintains two identical copies of all data in
memory for redundancy. Lockstep - The motherboard uses two areas of memory to run the same set of
operations in parallel. Sparing - A preset threshold of correctable errors is used to trigger fail-over.
The spare memory is put online and used as active memory in place of the failed memory.
Demand Scrubbing
A memory error-correction scheme where the Processor writes corrected data back into the memory block from where it was read by the Processor. The op­tions are Enabled and Disabled.
Patrol Scrubbing
A memory error-correction scheme that works in the background looking for and correcting resident errors. The options are Enabled and Disabled.
Memory ECC Error Threshold
This feature allows the user to set the correctable memory ECC error limit for AMI BIOS to handle it. The Default setting is 255.
Throttling - Closed Loop/Throttling - Open Loop
Throttling improves reliability and reduces power in the processor by automatic voltage control during processor idle states. Available options are Disabled and Enabled. If Enabled, the following items will appear:
Hysteresis Temperature (Available for Closed Loop only)
Temperature Hysteresis is the temperature lag (in degrees Celsius) after the set DIMM temperature threshold is reached before Closed Loop Throttling begins. The options are Disabled, 1.5oC, 3.0
o
C, and 6.0oC.
7-8
Chapter 7: BIOS
Guardband Temperature (Available for Closed Loop only)
This is the temperature which applies to the DIMM temperature threshold. Each step is in 0.5
o
C increment. The default is [006]. Press "+" or "-" on
your keyboard to change this value.
Inlet Temperature
o
This is the temperature detected at the chassis inlet. Each step is in 0.5
C increment. The default is [070]. Press "+" or "-" on your keyboard to change this value.
Temperature Rise
This is the temperature rise to the DIMM thermal zone. Each step is in
o
0.5
C increment. The default is [020]. Press "+" or "-" on your keyboard to
change this value.
Air Flow
This is the air fl ow speed to the DIMM modules. Each step is one mm/ sec. The default is [1500]. Press "+" or "-" on your keyboard to change this value.
Altitude
This feature defi nes how many meters above or below sea level the system is located. The options are Sea Level or Below, 1~300, 301~600, 601~900, 901~1200, 1201~1500, 1501~1800, 1801~2100, 2101~2400, 2401~2700, 2701~3000.
DIMM Pitch
This is the physical space between each DIMM module. Each step is in 1/1000 of an inch. The default is [400]. Press "+" or "-" on your keyboard to change this value.
Serial Debug Message Level
This feature allows the user to set the level of debug messages to be displayed. The options are None, MIN, MAX and Test.
XNorth Bridge Con guration
This feature allows the user to confi gure the settings for the Intel North Bridge chip.
Crystal Beach/DMA (Direct Memory Access)
This feature works with the Intel I/O AT (Acceleration Technology) to accelerate the performance of TOE devices. (Note: A TOE device is a specialized, dedicated
7-9
SUPERSERVER 7046T-NTR+ User's Manual
processor that is installed on an add-on card or a network card to handle some or all packet processing of this add-on card.) When this feature is set to Enabled, it will enhance overall system performance by providing direct memory access for data transferring. The options are Enabled and Disabled.
Crystal Beach/DCA (Direct Cache Access) (Available when Crystal Beach/ DMA is enabled)
This feature works in conjunction with the Intel I/O AT (Acceleration Technology) to accelerate the performance of the TOE device. When this feature set to Enabled, it will enhance overall system performance by providing direct cache access for data transferring. The options are Enabled and Disabled.
Intel VT-d
Select Enabled to enable Intel's Virtualization Technology support for Direct I/O VT-d by reporting the I/O device assignments to VMM through the DMAR ACPI Tables. This feature offers fully-protected I/O resource-sharing across the Intel platforms, providing the user with greater reliability, security and availability in networking and data-sharing. The settings are Enabled and Disabled.
XSouthBridge Con guration
This feature allows the user to confi gure the settings for the Intel ICH South Bridge chipset.
USB Functions
This feature allows the user to decide the number of onboard USB ports to be en­abled. The Options are: Disabled, 2 USB ports, 4 USB ports, 6 USB ports, 8 Ports, 10 Ports and 12 USB ports.
Legacy USB Support
Select Enabled to use Legacy USB devices. If this item is set to Auto, Legacy USB support will be automatically enabled if a legacy USB device is installed on the motherboard, and vise versa. The settings are Disabled, Enabled and Auto.
USB 2.0 Controller
This item indicated if the USB 2.0 controller is activated. The options are Enabled and Disabled.
USB 2.0 Controller Mode
This setting allows you to select the USB 2.0 Controller mode. The options are Hi-Speed (480 Mbps) and Full Speed (12 Mbps).
7-10
Chapter 7: BIOS
BIOS EHCI Hand-Off
Select Enabled to enable BIOS Enhanced Host Controller Interface support to provide a workaround solution for an operating system that does not have EHCI Hand-Off support. When enabled, the EHCI Interface will be changed from the BIOS­controlled to the OS-controlled. The options are Disabled and Enabled.
XIntel PCI-X Hub Confi guration
PCI Bus A0/B0 Frequency
This option allows the user to set the maximum PCI speed to be used in the PCI slot specifi ed. Select Auto to allow the BIOS to automatically detect the capability of the device installed on the bus. The options are Auto, 33 MHz PCI, 66 MHz PCI, 66 MHz PCI-X MI, 100 MHz PCI-X MI, and 133 MHz PCI-X MI.
I/O Port Decode
This option allows the user to select the decode range for the I/O connections. The options are 4K Decode and 1K Decode.
RAS Sticky Error Handling
This option allows the user to decide how to handle Sticky RAS errors. The options are Clear Errors and Leave Errors (unchanged).
VGA 16-Bit Decode
Select Enabled to enable the function of decoding VGA for the devices installed behind the PXH PCI Controller Hub. The options are Enabled and Disabled.
XIDE/SATA/Floppy Con guration
When this submenu is selected, the AMI BIOS automatically detects the presence of the IDE devices and displays the following items:
SATA#1 Confi guration
If Compatible is selected, it sets SATA#1 to legacy compatibility mode, while se­lecting Enhanced sets SATA#1 to native SATA mode. The options are Disabled,
Compatible and Enhanced.
Confi gure SATA#1 as
This feature allows the user to select the drive type for SATA#1. The options are IDE, RAID and AHCI. (When the option-RAID is selected, the item-ICH RAID Code Base will appear. When the option-AHCI is selected, the item-SATA AHCI will be available.)
7-11
SUPERSERVER 7046T-NTR+ User's Manual
ICH RAID Code Base (This feature is available when the option-RAID is selected)
Select Intel to enable Intel's SATA RAID fi rmware to confi gure Intel's SATA RAID settings. Select Adaptec to enable Adaptec's SATA RAID fi rmware to confi gure Adaptec's SATA RAID settings. The options are Intel and Adaptec.
SATA AHCI (This feature is available when the option-AHCI is selected)
Select Enable to enable the function of Serial ATA Advanced Host Interface. (T ake caution when using this function. This feature is for advanced programmers only.) The options are Enabled and Disabled. If the option-Enabled is selected, the following item will display.
SATA#2 Confi guration (This feature is available when the option-IDE is selected)
Selecting Enhanced will set SATA#2 to native SATA mode. The options are Disabled, and Enhanced.
Primary IDE Master/Slave, Secondary IDE Master/Slave, Third IDE Master, and Fourth IDE Master
These settings allow the user to set the parameters of Primary IDE Master/Slave, Secondary IDE Master/Slave, Third and Fourth IDE Master slots. Hit <Enter> to activate the following submenu screen for detailed options of these items. Set the correct confi gurations accordingly. The items included in the submenu are:
Type
Select the type of device connected to the system. The options are Not Installed,
Auto, CD/DVD and ARMD.
LBA/Large Mode
LBA (Logical Block Addressing) is a method of addressing data on a disk drive. In the LBA mode, the maximum drive capacity is 137 GB. For drive capacities over 137 GB, your system must be equipped with a 48-bit LBA mode addressing. If not, contact your manufacturer or install an ATA/133 IDE controller card that supports 48-bit LBA mode. The options are Disabled and Auto.
Block (Multi-Sector Transfer)
Block Mode boosts the IDE drive performance by increasing the amount of data transferred. Only 512 bytes of data can be transferred per interrupt if Block Mode is not used. Block Mode allows transfers of up to 64 KB per interrupt. Select Disabled to allow data to be transferred from and to the device one sector at a time. Select Auto to allow data transfer from and to the device occur multiple sectors at a time if the device supports it. The options are Auto and Disabled.
7-12
Chapter 7: BIOS
PIO Mode
The IDE PIO (Programmable I/O) Mode programs timing cycles between the IDE drive and the programmable IDE controller. As the PIO mode increases, the cycle time decreases. The options are Auto, 0, 1, 2, 3, and 4.
Select Auto to allow the AMI BIOS to automatically detect the PIO mode. Use this value if the IDE disk drive support cannot be determined.
Select 0 to allow the AMI BIOS to use PIO mode 0. It has a data transfer rate of 3.3 MBs.
Select 1 to allow the AMI BIOS to use PIO mode 1. It has a data transfer rate of 5.2 MBs.
Select 2 to allow the AMI BIOS to use PIO mode 2. It has a data transfer rate of 8.3 MBs.
Select 3 to allow the AMI BIOS to use PIO mode 3. It has a data transfer rate of 11.1 MBs.
Select 4 to allow the AMI BIOS to use PIO mode 4. It has a data transfer band­width of 32-Bits. Select Enabled to enable 32-Bit data transfer.
DMA Mode
Select Auto to allow the BIOS to automatically detect IDE DMA mode when the IDE disk drive support cannot be determined.
Select SWDMA0 to allow the BIOS to use Single Word DMA mode 0. It has a data transfer rate of 2.1 MBs.
Select SWDMA1 to allow the BIOS to use Single Word DMA mode 1. It has a data transfer rate of 4.2 MBs.
Select SWDMA2 to allow the BIOS to use Single Word DMA mode 2. It has a data transfer rate of 8.3 MBs.
Select MWDMA0 to allow the BIOS to use Multi Word DMA mode 0. It has a data transfer rate of 4.2 MBs.
Select MWDMA1 to allow the BIOS to use Multi Word DMA mode 1. It has a data transfer rate of 13.3 MBs.
Select MWDMA2 to allow the BIOS to use Multi-Word DMA mode 2. It has a data transfer rate of 16.6 MBs.
Select UDMA0 to allow the BIOS to use Ultra DMA mode 0. It has a data transfer rate of 16.6 MBs. It has the same transfer rate as PIO mode 4 and Multi Word DMA mode 2.
Select UDMA1 to allow the BIOS to use Ultra DMA mode 1. It has a data transfer rate of 25 MBs.
7-13
SUPERSERVER 7046T-NTR+ User's Manual
Select UDMA2 to allow the BIOS to use Ultra DMA mode 2. It has a data transfer rate of 33.3 MBs.
Select UDMA3 to allow the BIOS to use Ultra DMA mode 3. It has a data transfer rate of 66.6 MBs.
Select UDMA4 to allow the BIOS to use Ultra DMA mode 4. It has a data transfer rate of 100 MBs.
Select UDMA5 to allow the BIOS to use Ultra DMA mode 5. It has a data transfer rate of 133 MBs.
Select UDMA6 to allow the BIOS to use Ultra DMA mode 6. It has a data transfer rate of 133 MBs. The options are Auto, SWDMAn, MWDMAn, and UDMAn.
S.M.A.R.T. For Hard disk drives
Self-Monitoring Analysis and Reporting Technology (SMART) can help predict impending drive failures. Select Auto to allow the AMI BIOS to automatically de­tect hard disk drive support. Select Disabled to prevent the AMI BIOS from using the S.M.A.R.T. Select Enabled to allow the AMI BIOS to use the S.M.A.R.T. to support hard drive disk. The options are Disabled, Enabled, and Auto.
32Bit Data Transfer
Select Enable to enable the function of 32-bit IDE data transfer. The options are
Enabled and Disabled.
Hot Plug (This feature is available when the option-AHCI Under "Confi igure SATA#1 as" is selected)
Select Enable to enable the hot plug function for the SATA devices. The options are Enabled and Disabled.
IDE Detect Timeout (sec)
Use this feature to set the time-out value for the BIOS to detect the ATA, ATAPI devices installed in the system. The options are 0 (sec), 5, 10, 15, 20, 25, 30, and
35.
XPCI/PnP Confi guration
Clear NVRAM This feature clears the NVRAM during system boot. The options are No and Yes.
Plug & Play OS
Selecting Yes allows the OS to confi gure Plug & Play devices. (This is not required for system boot if your system has an OS that supports Plug & Play.) Select No to allow the AMI BIOS to confi gure all devices in the system.
7-14
Chapter 7: BIOS
PCI Latency Timer
This feature sets the latency Timer of each PCI device installed on a PCI bus. Select 64 to set the PCI latency to 64 PCI clock cycles. The options are 32, 64, 96, 128, 160, 192, 224 and 248.
PCI IDE BusMaster
When enabled, the BIOS uses PCI bus mastering for reading/writing to IDE drives. The options are Disabled and Enabled.
Load Onboard LAN1 Option ROM/Load Onboard LAN2 Option ROM
Selec t Enabled to e n a ble the on board LAN1 or LAN2 Option ROM. This is to boot computer using a network interface. The options are Enabled and Disabled.
XSuper IO Device Confi guration
Onboard Floppy Controller
Select Enabled to enable the onboard fl oppy controller. The options are Disabled and Enabled.
Floppy Drive Swap
Select Enabled to enable fl oppy drive swap. The options are Disabled and En- abled.
Serial Port1 Address/ Serial Port2 Address
This option specifi es the base I/O port address and the Interrupt Request address of Serial Port 1 and Serial Port 2. Select Disabled to prevent the serial port from accessing any system resources. When this option is set to Disabled, the serial port physically becomes unavailable. Select 3F8/IRQ4 to allow the serial port to use 3F8 as its I/O port address and IRQ 4 for the interrupt address. The options for Serial Port1 are Disabled, 3F8/IRQ4, 3E8/IRQ4, 2E8/IRQ3. The options for Serial Port2 are Disabled, 2F8/IRQ3, 3E8/IRQ4, and 2E8/IRQ3.
XRemote Access Confi guration
Remote Access
This allows the user to enable the Remote Access feature. The options are Disabled and Enabled.
If Remote Access is set to Enabled, the following items will display:
7-15
SUPERSERVER 7046T-NTR+ User's Manual
Serial Port Number
This feature allows the user decide which serial port to be used for Console Redi­rection. The options are COM 1 and COM 2.
Base Address, IRQ
This item displays the based address and IRQ of the serial port specifi ed above. The options are COM 1 and COM 2.
Serial Port Mode
This feature allows the user to set the serial port mode for Console Redirection. The options are 115200 8, n 1; 57600 8, n, 1; 38400 8, n, 1; 19200 8, n, 1; and 9600 8, n, 1.
Flow Control
This feature allows the user to set the fl ow control for Console Redirection. The options are None, Hardware, and Software.
Redirection After BIOS POST
Selec t Disab l ed to turn off Console Redirec tion after Power-On Sel f -Test (POST). Selec t Always to kee p Cons ole Re direc tio n acti ve all the t ime af ter P OST. (Note: This setting may not be supported by some operating systems.) Select Boot Loader to keep Con sole Redirec tion active du ring POST and B oot Loader. The option s are Disa bled, B oot Loade r, and Always.
Terminal Type
This feature allows the user to select the target terminal type for Console Redirec­tion. The options are ANSI, VT100, and VT-UTF8.
VT-UTF8 Combo Key Support
A terminal keyboard defi nition that provides a way to send commands from a remote console. Available options are Enabled and Disabled.
Sredir Memory Display Delay
This feature defi nes the length of time in seconds to display memory information. The options are No Delay, Delay 1 Sec, Delay 2 Sec, and Delay 4 Sec.
XHardware Health Monitor
This feature allows the user to monitor system health and review the status of each item as displayed.
7-16
Chapter 7: BIOS
!
CPU Overheat Alarm
This option allows the user to select the CPU Overheat Alarm setting which de­termines when the CPU OH alarm will be activated to provide warning of possible CPU overheat.
Warning! 1.Any temperature that exceeds the CPU threshold tempera­ture predefi ned by the CPU manufacturer may result in CPU overheat or system instability. When the CPU temperature reaches this predefi ned threshold, the CPU and system cooling fans will run at full speed. 2. To avoid possible system overheating, please be sure to provide adequate airfl ow to your system.
The options are:
The Early Alarm: Select this setting if you want the CPU overheat alarm (includ-
ing the LED and the buzzer) to be triggered as soon as the CPU temperature reaches the CPU overheat threshold as predefi ned by the CPU manufacturer.
The Default Alarm
: Select this setting if you want the CPU overheat alarm
(including the LED and the buzzer) to be triggered when the CPU temperature reaches about 5 manufacturer to give the CPU and system fans additional time needed for CPU and system cooling. In both the alarms above, please take immediate action as shown below.
CPU Temperature/System Temperature
This feature displays current temperature readings for the CPU and the System. The following items will be displayed for your reference only:
CPU Temperature
The CPU thermal technology that reports absolute temperatures (Celsius/Fahr­enheit) has been upgraded to a more advanced feature by Intel in its newer processors. The basic concept is each CPU is embedded by unique temperature information that the motherboard can read. This ‘Temperature Threshold’ or ‘Tem­perature Tolerance’ has been assigned at the factory and is the baseline on which the motherboard takes action during different CPU temperature conditions (i.e., by increasing CPU Fan speed, triggering the Overheat Alarm, etc). Since CPUs can have different ‘Temperature Tolerances’, the installed CPU can now send informa­tion to the motherboard what its ‘Temperature Tolerance’ is, and not the other way around. This results in better CPU thermal management.
o
C above the threshold temperature as predefi ned by the CPU
Supermicro has leveraged this feature by assigning a temperature status to certain thermal conditions in the processor (Low, Medium and High). This makes it easier for the user to understand the CPU’s temperature status, rather than by just simply
7-17
SUPERSERVER 7046T-NTR+ User's Manual
seeing a temperature reading (i.e., 25oC). The CPU Temperature feature will display the CPU temperature status as detected by the BIOS:
Low – This level is considered as the ‘normal’ operating state. The CPU temperature is well below the CPU ‘Temperature Tolerance’. The motherboard fans and CPU will run normally as confi gured in the BIOS (Fan Speed Control).
User intervention: No action required. Medium – The processor is running warmer. This is a ‘precautionary’ level and
generally means that there may be factors contributing to this condition, but the CPU is still within its normal operating state and below the CPU ‘Temperature Tolerance’. The motherboard fans and CPU will run normally as confi gured in the BIOS. The fans may adjust to a faster speed depending on the Fan Speed Control settings.
User intervention: No action is required. However, consider checking the CPU fans and the chassis ventilation for blockage.
High – The processor is running hot. This is a ‘caution’ level since the CPU’s ‘Tem­perature Tolerance’ has been reached (or has been exceeded) and may activate an overheat alarm.
User intervention: If the system buzzer and Overheat LED has activated, take action immediately by checking the system fans, chassis ventilation and room temperature to correct any problems.
Notes: The system may shut down if it continues for a long period to prevent dam­age to the CPU.
The information provided above is for your reference only. For more information on thermal management, please refer to Intel’s Web site at www.intel.com.
System Temperature: The system temperatu re will b e displayed ( in degre es in Celsiu s and Fahrenh eit) as it is detec ted by the BI OS.
Fan Speed Readings
This feature displays the fan speed readings from Fan1 through Fan8.
Fan Speed Control Monitor
This feature allows the user to decide how the system controls the speeds of the onboard fans. The CPU temperature and the fan speed are correlative. When the CPU on-die temperature increases, the fan speed will also increase, and vice versa. Select Workstation if your system is used as a Workstation. Select Server if your system is used as a Server. Select “Disabled, (Full Speed @12V)” to disable the fan speed control function and allow the onboard fans to constantly run at the full speed (12V). The Options are: 1. Disabled (Full Speed), 2. Server Mode, 3. Workstation Mode.
7-18
Chapter 7: BIOS
Voltages Readings
The following voltage readings will be displayed. CPU1 Vcore, CPU2 Vcore, +5Vin, +12V, -12V 3.3Vcc (V), and Battery Voltage
XACPI Con guration
Use this feature to confi gure Advanced Confi guration and Power Interface (ACPI) power management settings for your system.
ACPI Version Features
The options are ACPI v1.0, ACPI v2.0 and ACPI v3.0. Please refer to ACPI's website for further explanation: http://www.acpi.info/.
ACPI APIC Support
Select Enabled to include the ACPI APIC Table Pointer in the RSDT (Root System Description Table) pointer list. The options are Enabled and Disabled.
APIC ACPI SCI IRQ
When this item is set to Enabled, APIC ACPI SCI IRQ is supported by the system. The options are Enabled and Disabled.
Headless Mode
This feature is used to enable system to function without a keyboard, monitor or mouse attached The options are Enabled and Disabled.
High Performance Event Timer
Select Enabled to activate the High Performance Event Timer (HPET) that produces periodic interrupts at a much higher frequency than a Real-time Clock (RTC) does in synchronizing multimedia streams, providing smooth playback and reducing the de­pendency on other timestamp calculation devices, such as an x86 RDTSC Instruc­tion embedded in the CPU. The High Performance Event Timer is used to replace the 8254 Programmable Interval Timer. The options are Enabled and Disabled.
XTrusted Computing
TCG/TPM Support
Select Yes on this item and enable the TPM jumper on the motherboard to enable TCG (TPM 1.1/1.2)/TPM support in order to improve data integrity and network security. The options are No and Yes.
If this feature is set to Yes, the following items will display:
7-19
SUPERSERVER 7046T-NTR+ User's Manual
TPM Enable/Disable Status
This item displays the status of TPM Support to indicate if TPM is currently enabled or disabled.
TPM Owner Status
This item displays the status of TPM Ownership.
XIPMI Con guration
Intelligent Platform Management Interface (IPMI) is a set of common interfaces that IT administrators can use to monitor system health and to manage the system as a whole. For more information on the IPMI specifi cations, please visit Intel's website at www.intel.com.
Status of BMC
Baseboard Management Controller (BMC) manages the interface between system management software and platform hardware. This is an informational feature which returns the status code of the BMC micro controller.
XView BMC System Event Log
This feat ur e d i sp l ays t h e BMC Sys te m Event Log (SEL). It shows the total number of entries of BMC System Events. To view an event, select an Entry Number and pressing <Enter> to display the information as shown in the screen.
Total Number of Entries
SEL Entry Number
SEL Record ID
SEL Record Type
Timestamp, Generator ID
Event Message Format User
Event Sensor Type
Event Sensor Number,
Event Dir Type
Event Data.
7-20
Chapter 7: BIOS
!
Clear BMC System Event Log
Select OK and press the <Enter> key to clear the BMC system log. Select Cancel to keep the BMC System log. The options are OK and Cancel.
Caution: Any cleared information is unrecoverable. Make absolutely sure that you no longer need any data stored in the log before clearing the BMC Event Log.
XSet LAN Con guration
Set this feature to confi gure the IPMI LAN adapter with a network address as shown in the following graphics.
Channel Number - Enter the channel number for the SET LAN Confi g com- mand. This is initially set to [1]. Press "+" or "-" on your keyboard to change the Channel Number.
Channel Number Status - This feature returns the channel status for the Channel Number selected above: "Channel Number is OK" or "Wrong Channel Number".
XIP Address Con guration
Enter the IP address for this machine. This should be in decimal and in dotted quad form (i.e., 192.168.10.253). The value of each three-digit number separated by dots should not exceed 255 as shown in the screen below.
Parameter Selector
Use this feature to select the parameter of your IP Address confi guration.
IP Address
The BIOS will automatically enter the IP address of this machine; however it may be over-ridden. IP addresses are 6 two-digit hexadecimal numbers (Base 16, 0 ~ 9, A, B, C, D, E, F) separated by dots. (i.e., 00.30.48.D0.D4.60).
Current IP Address in BMC
This item displays the current IP address used for your IPMI connection.
XMAC Address Con guration
Enter the Mac address for this machine. This should be in decimal and in dotted quad form (i.e., 192.168.10.253). The value of each three-digit number separated by dots should not exceed 255 as shown in the screen below.
7-21
SUPERSERVER 7046T-NTR+ User's Manual
Parameter Selector
Use this feature to select the parameter of your Mac Address confi guration.
Mac Address
The BIOS will automatically enter the Mac address of this machine; however it may be over-ridden. Mac addresses are 6 two-digit hexadecimal numbers (Base 16, 0 ~ 9, A, B, C, D, E, F) separated by dots. (i.e., 00.30.48.D0.D4.60).
Current Mac Address in BMC
This item displays the current Mac address used for your IPMI connection.
XSubnet Mask Con guration
Subnet masks tell the network which subnet this machine belongs to. The value of each three-digit number separated by dots should not exceed 255.
Parameter Selector
Use this feature to select the parameter of your Subnet Masks confi guration.
Subnet Mask
This item displays the current subnet mask setting for your IPMI connection.
XSEL PEF Confi guration
PEF Support
Select Enabled to enable the function of Platform Event Filter (PEF) which will interpret BMC events and perform actions based on pre-determined settings or events and performs actions based on pre-determined settings or 'traps' under IPMI 1.5 specifi cations. For example, powering the system down or sending an alert when a triggering event is detected. The default is Disabled.
The following will appear if PEF Support is set to Enabled.
PEF Action Global Control (Available if the item-PEF Support is enabled)
These are the different actions based on BMC events. The options are Alert, Power Down, Reset System, Power Cycle, OEM Action, Diagnostic Interface.
Alert Startup Delay (Available if the item-PEF Support is enabled)
This feature inserts a delay during startup for PEF alerts. The options are En­abled and Disabled.
7-22
Chapter 7: BIOS
PEF Alert Startup Delay (Available if the item-PEF Support is enabled)
This sets the pre-determined time to delay PEF alerts after system power-ups and resets. Refer to Table 24.6 of the IPMI 1.5 Specifi cation for more information at www.intel.com. The options are No Delay, 30 sec, 60 sec, 1.5 min, 2.0 min.
Startup Delay (Available if the item-PEF Support is enabled) This feature enables or disables startup delay. The options are Enabled and
Disabled.
PEF Startup Delay (Available if the item-PEF Startup is enabled)
This sets the pre-determined time to delay PEF after system power-ups and resets. Refer to Table 24.6 of the IPMI 1.5 Specifi cation for more information at www.intel.com. The options are No Delay, 30 sec, 60 sec, 1.5 min, 2.0 min.
Event Message for PEF Action (Available if the item-PEF Support is enabled)
This enables of disables Event Messages for PEF action. Refer to Table 24.6 of the IPMI 1.5 Specifi cation for more information at www.intel.com. The options are Disabled and Enabled.
BMC Watch Dog Timer Action
Allows the BMC to reset or power down the system if the operating system hangs or crashes. The options are Disabled, Reset System, Power Down, Power Cycle.
BMC Watch Dog TimeOut [Min:Sec]
This option appears if BMC Watch Dog Timer Action (above) is enabled. This is a timed delay in minutes or seconds, before a system power down or reset after an operating system failure is detected. The options are [5 Min], [1 Min], [30 Sec], and [10 Sec].
XDMI Event Log
View Event Log
Use this option to view the System Event Log.
Mark all events as read
This option marks all events as read. The options are OK and Cancel.
Clear event log
This option clears the Event Log memory of all messages. The options are OK and Cancel.
7-23
SUPERSERVER 7046T-NTR+ User's Manual
7-4 Security Settings
The AMIBIOS Setup Utility provides a Supervisor and a User password. If you use both passwords, the Supervisor password must be set fi rst.
Supervisor Password
This feature indicates if a supervisor's password has been entered (installed).
User Password
This feature indicates if a user's password has been entered (installed).
Change Supervisor Password
Select this option and press <Enter> to access the submenu, and then enter the password.
Change User Password
Select this option and press <Enter> to access the submenu, and then enter the password.
Clear User Password (Available only if User Password has been set) This item allows you to clear a user password after it has been entered.
Password Check
This item allows you to check a password after it has been entered. The options are Setup and Always.
Boot Sector Virus Protection
When Enabled, the AMI BIOS displays a warning when any program (or virus) is­sues a Disk Format command or attempts to write to the boot sector of the hard disk drive. The options are Enabled and Disabled.
7-24
7-5 Boot Confi guration
Use this feature to confi gure boot settings.
Chapter 7: BIOS
XBoot Device Priority
This feature allows the user to specify the sequence of priority for the Boot Device. The settings are 1st boot device, 2nd boot device, 3rd boot device, 4th boot device, 5th boot device and Disabled.
1st Boot Device - [USB: XXXXXXXXX]
2nd Boot Device - [CD/DVD: XXXXXXXXX]
XHard Disk Drives
This feature allows the user to specify the boot sequence from all available hard disk drives. The settings are Disabled and a list of all hard disk drives that have been detected (i.e., 1st Drive, 2nd Drive, 3rd Drive, etc).
1st Drive - [SATA: XXXXXXXXX]
XRemovable Drives
This feature allows the user to specify the boot sequence from available Removable Drives. The settings are 1st boot device, 2nd boot device, and Disabled.
1st Drive - [USB: XXXXXXXXX]
2nd Drive
7-25
SUPERSERVER 7046T-NTR+ User's Manual
7-6 Exit Options
Select the Exit tab from the AMI BIOS Setup Utility screen to enter the Exit BIOS Setup screen.
Save Changes and Exit
When you have completed the system confi guration changes, select this option to leave the BIOS Setup Utility and reboot the computer, so the new system con­ guration parameters can take effect. Select Save Changes and Exit from the Exit menu and press <Enter>.
Discard Changes and Exit
Select this option to quit the BIOS Setup without making any permanent changes to the system confi guration, and reboot the computer. Select Discard Changes and Exit from the Exit menu and press <Enter>.
Discard Changes
Select this option and press <Enter> to discard all the changes and return to the AMI BIOS Utility Program.
Load Optimal Defaults
To set this feature, select Load Optimal Defaults from the Exit menu and press <Enter>. Then, select OK to allow the AMI BIOS to automatically load Optimal De­faults to the BIOS Settings. The Optimal settings are designed for maximum system performance, but may not work best for all computer applications.
Load Fail-Safe Defaults
To set this feature, select Load Fail-Safe Defaults from the Exit menu and press <Enter>. The Fail-Safe settings are designed for maximum system stability, but not for maximum performance.
7-26
Appendix A: BIOS Error Beep Codes
Appendix A
BIOS Error Beep Codes
During the POST (Power-On Self-Test) routines, which are performed each time the system is powered on, errors may occur.
Non-fatal errors are those which, in most cases, allow the system to continue the boot-up process. The error messages normally appear on the screen.
Fatal errors are those which will not allow the system to continue the boot-up procedure. If a fatal error occurs, you should consult with your system manufac­turer for possible repairs.
These fatal errors are usually communicated through a series of audible beeps. The numbers on the fatal error list correspond to the number of beeps for the corresponding error.
BIOS Error Beep Codes
Beep Code Error Message Description
1 beep Refresh Circuits have been reset.
(Ready to power up)
5 short beeps + 1 long beep
8 beeps Display memory
1 continuous beep w/ Front Panel OH LED on
Memory error No memory detected in the
system Video adapter missing or with
read/write error System Overheat 1 continuous beep with the
faulty memory
front panel OH LED on
A-1
SUPERSERVER 7046T-NTR+ User's Manual
Notes
A-2
Loading...