Supermicro SUPERSERVER 6022C User Manual

®
SUPERSERVER 6022C
USER’S MANUAL
Revision 1.0a
SUPER
The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccuracies that may be contained in this document, makes no commitment to update or to keep current the information in this manual, or to notify any person or organization of the updates.
Please Note: For the most up-to-date version of this manual, please see our web site at www.supermicro.com.
SUPERMICRO COMPUTER reserves the right to make changes to the product described in this manual at any time and without notice. This product, including software, if any, and documentation may not, in whole or in part, be copied, photocopied, reproduced, translated or reduced to any medium or machine without prior written consent.
IN NO EVENT WILL SUPERMICRO COMPUTER BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL, SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO USE THIS PRODUCT OR DOCUMENTATION, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. IN PARTICULAR, THE VENDOR SHALL NOT HAVE LIABILITY FOR ANY HARDWARE, SOFTWARE, OR DATA STORED OR USED WITH THE PRODUCT, INCLUDING THE COSTS OF REPAIRING, REPLACING, INTEGRATING, INSTALLING OR RECOVERING SUCH HARDWARE, SOFTWARE, OR DATA.
Any disputes arising between manufacturer and customer shall be governed by the laws of Santa Clara County in the State of California, USA. The State of California, County of Santa Clara shall be the exclusive venue for the resolution of any such disputes. Supermicro's total liability for all claims will not exceed the price paid for the hardware product.
Unless you request and receive written permission from SUPER MICRO COMPUTER, you may not copy any part of this document.
Information in this document is subject to change without notice. Other products and companies referred to herein are trademarks or registered trademarks of their respective companies or mark holders.
Copyright © 2002 by SUPER MICRO COMPUTER INC. All rights reserved.
Printed in the United States of America.
Preface
About This Manual
This manual is written for professional system integrators and PC techni­cians. It provides information for the installation and use of the Super­Server 6022C. Installation and maintainance should be performed by expe­rienced technicians only.
The SuperServer 6022C is a high-end dual processor 2U rackmount server based on the SC822 2U rackmount server chassis and the P4DC6+, a dual processor motherboard that supports single or dual Intel® XeonTM 603-pin
1.5 -2.4+ GHz processors at a front side (system) bus speed of 400 MHz and up to 2 GB 600/800 MHz RDRAM main memory.
Manual Organization
Chapter 1: Introduction
The first chapter provides a checklist of the main components included with the server system and describes the main features of the SUPER P4DC6+ mainboard and the SC822 chassis, which make up the SuperServer 6022C.
Chapter 2: Server Installation
This chapter describes the steps necessary to install the SuperServer 6022C into a rack and check out the server configuration prior to powering up the system. If your server was ordered without processor and memory components, this chapter will refer you to the appropriate sections of the manual for their installation.
Chapter 3: System Interface
Refer here for details on the system interface, which includes the functions and information provided by the control panel on the chassis as well as other LEDs located throughout the system.
iii
Preface
SUPERSERVER 6022C User's Manual
iv
Chapter 4: System Safety
You should thoroughly familiarize yourself with this chapter for a general overview of safety precautions that should be followed when installing and servicing the SuperServer 6022C.
Chapter 5: Advanced Motherboard Setup
Chapter 5 provides detailed information on the P4DC6+ motherboard, includ­ing the locations and functions of connections, headers, jumpers and IRQs. Refer to this chapter when adding or removing processors or main memory and when reconfiguring the motherboard.
Chapter 6: Advanced Chassis Setup
Refer to Chapter 6 for detailed information on the SC822 2U rackmount server chassis. You should follow the procedures given in this chapter when installing, removing or reconfiguring SCSI or peripheral drives and when replacing system power supply units and cooling fans.
Chapter 7: BIOS
The BIOS chapter includes an introduction to BIOS and provides detailed information on running the CMOS Setup Utility.
Appendix A: AwardBIOS POST Messages
Appendix B: AwardBIOS POST
Appendix C: AwardBIOS Error BeepCodes
Appendix D: System Specifications
v
Preface
Manual Organization
Installation System
Interface
System
Safety
Motherboard
Details
Chassis
Details
BIOS and
Setup Routine
Chp3Chp2
Chp5
Chp4
Chp6
Appendices
Overview
Precautions
Rack
Installation
Setup
Overview
Control Panel
Buttons
Control Panel
LEDs
SCSI LEDs
Motherboard
LED
Sta tic Sa fe ty
M B Insta lla tio n
Cables
I/O Po r ts
CPU Installation
Memory
PCI Cards
MB La yout
Connectors
Jumpers
Drive Conn.
Software
Sta tic Sa fe ty
Control Panel
System F ans
Drive Bay Inst.
Power Supply
Chp7 App. A/B/C/D
Introduction
BIOS Features
Running CM O S
Setup
Ele c trical S afe ty
Ge ner a l S afe ty
ESD Safety
AwardBIOS POST
Messages
AwardBIOS
Post Codes
AwardBIOS Error
Beep Codes
System Spec s
Operating
Precautions
SUPERSERVER 6022C User's Manual
vi
Table of Contents
Preface
About This Manual ...................................................................................................... iii
Manual Organization ................................................................................................... iii
Manual Organization (Flowchart)............................................................................. v
Chapter 1: Introduction to the SuperServer 6022C
1-1 Overview ......................................................................................................... 1-1
1-2 Server Chassis Features.............................................................................. 1-2
1-3 Mainboard Features ....................................................................................... 1-4
1-4 Contacting Supermicro .................................................................................. 1-6
Chapter 2: Server Installation
2-1 Overview ......................................................................................................... 2-1
2-2 Unpacking the SuperServer 6022C............................................................. 2-1
2-3 Preparing for Setup ....................................................................................... 2-1
Choosing a Setup Location .................................................................... 2-2
Rack Precautions ..................................................................................... 2-2
Server Precautions.................................................................................. 2-2
2- 4 Installing the SuperServer 6022C into a Rack .......................................... 2-3
Identifying the Sections of the Rack Rails .......................................... 2-3
Installing the Chassis Rails ..................................................................... 2 - 4
Installing the Rack Rails .......................................................................... 2 - 4
Installing the Server into the Rack ........................................................ 2 -5
Installing the Server into a Telco Rack ................................................2- 6
2- 5 Checking the Motherboard Setup ................................................................ 2-7
2-6 Checking the Drive Bay Setup ..................................................................... 2-9
2-7 Checking the System Airflow .................................................................... 2-10
2-8 Supplying Power to the System ................................................................ 2-10
Chapter 3: System Interface
3-1 Overview ......................................................................................................... 3-1
3- 2 Control Panel Buttons .................................................................................... 3-1
Reset .......................................................................................................... 3-1
Power ........................................................................................................ 3-1
3-3 Control Panel LEDs ........................................................................................ 3-2
Overheat ................................................................................................... 3-2
NIC .............................................................................................................. 3-2
HDD ............................................................................................................ 3-2
Power ........................................................................................................ 3-3
3- 4 SCSI Drive Carrier LEDs ............................................................................... 3-3
3- 5 Motherboard LED ............................................................................................ 3-3
Chapter 4: System Safety
4-1 Electrical Safety Precautions ........................................................................ 4-1
4-2 General Safety Precautions .......................................................................... 4-2
4- 3 ESD Precautions.............................................................................................. 4-3
4-4 Operating Precautions .................................................................................... 4-4
Chapter 5: Advanced Motherboard Setup
5- 1 Handling the P4DC6+ Motherboard............................................................... 5-1
5- 2 Motherboard Installation ................................................................................. 5 -2
5-3 Connecting Cables .......................................................................................... 5 - 3
Connecting Data Cables .......................................................................... 5 -3
Connecting Power Cables....................................................................... 5 -3
Connecting the Control Panel ................................................................. 5 - 4
5- 4 I/O Ports ............................................................................................................ 5-5
5-5 Installing Processors ...................................................................................... 5-5
5- 6 Installing Memory............................................................................................. 5-8
5- 7 Adding PCI Cards ............................................................................................ 5-9
Super P4DC6+ Layout........................................................................... 5- 12
Super P4DC6+ Quick Reference ......................................................... 5-13
5-8 Connector Definitions ................................................................................... 5-14
Power Supply Connectors ................................................................... 5-14
PWR_LED ................................................................................................. 5-15
IDE Hard Drive LED................................................................................ 5-15
PWR_On ................................................................................................... 5-15
Reset ......................................................................................................... 5-15
USB Keyboard ........................................................................................ 5-16
Alarm Reset ............................................................................................ 5-16
Fan Fail LED............................................................................................. 5-16
Power FAIL LED .................................................................................... 5-16
NIC LED.................................................................................................... 5-16
I2C ............................................................................................................. 5-17
Chassis Intrusion ................................................................................... 5-17
Keyboard Lock ........................................................................................ 5-17
Overheat ................................................................................................. 5-17
Speaker .................................................................................................... 5-17
vii
Table of Contents
SUPERSERVER 6022C User's Manual
viii
ATX PS/2 Keyboard and Mouse Ports ................................................ 5-18
Universal Serial Bus (USB) ................................................................... 5-18
Serial Ports ............................................................................................. 5-18
Wake On LAN (WOL) ........................................................................... 5- 18
CD Headers............................................................................................. 5-19
Fan Headers ........................................................................................... 5-19
Overheat LED (JOH) ............................................................................... 5-19
Infrared Connector ................................................................................. 5-19
Wake-On-Ring ......................................................................................... 5-20
5- 9 Jumper Settings ............................................................................................. 5-21
Explanation of Jumpers ......................................................................... 5-21
CMOS Clear.............................................................................................. 5-21
Keyboard Wakeup .................................................................................. 5-22
USB Wake-Up.......................................................................................... 5-22
SCSI Termination Enable/Disable.......................................................... 5-23
Onboard Audio ........................................................................................ 5-23
LAN (NIC) Enable/Disable ...................................................................... 5-23
SCSI Enable/Disable................................................................................ 5-23
Third Power Supply Fail Alarm Enable/Disable .................................. 5-24
64-bit PCI Speed Select......................................................................... 5-24
5-10 Parallel Port, AGP and Floppy/HardDisk Drive Connections.................. 5-25
Parallel Port Connector ......................................................................... 5- 25
Floppy Connector ................................................................................... 5-26
IDE Connectors ...................................................................................... 5- 26
AGP Pro Slot .......................................................................................... 5-27
50-pin Legacy SCSI Connector ............................................................ 5-27
Ultra Wide SCSI Connector ................................................................... 5-28
5-11 Installing Software Drivers.......................................................................... 5-29
Chapter 6: Advanced Chassis Setup
6-1 Static-Sensitive Devices ................................................................................ 6-1
6-2 Control Panel .................................................................................................... 6-2
6-3 System Fans .................................................................................................... 6-3
System Fan Failure .................................................................................. 6-3
Replacing System Cooling Fans ............................................................ 6-3
6- 4 Drive Bay Installation/Removal ...................................................................... 6-4
Accessing the Drive Bays ..................................................................... 6-4
SCSI Drive Installation............................................................................. 6-5
CD-ROM and Floppy Drive Installation ................................................. 6-7
Table of Contents
ix
Installing Components into the 5.25" Drive Bay .................................. 6 - 8
6-5 Power Supply .................................................................................................. 6-9
Power Supply Failure ............................................................................. 6-9
Removing/Replacing the Power Supply ............................................... 6-9
Chapter 7: BIOS
7- 1 Introduction....................................................................................................... 7 -1
7- 2 Running Setup.................................................................................................. 7-2
7- 3 Main BIOS Setup.............................................................................................. 7-2
The Main BIOS Setup Menu .................................................................... 7-3
7-4 Advanced BIOS Setup .................................................................................... 7 -6
Advanced BIOS Features ....................................................................... 7-6
Advanced Chipset Features ................................................................... 7-8
Integrated Peripherals ............................................................................ 7-11
Hardware Monitors................................................................................. 7-14
Processor Features................................................................................ 7-15
PnP/PCI Configurations ..........................................................................7-16
Power Management ................................................................................ 7-18
Boot-up Devices ..................................................................................... 7-21
Security Setup ........................................................................................ 7-23
Exit Setup ................................................................................................. 7-25
Appendices:
Appendix A: AwardBIOS POST Messages ......................................................... A -1
Appendix B: AwardBIOS POST Codes ................................................................. B- 1
Appendix C: AwardBIOS Error Beep Codes........................................................ C-1
Appendix D: System Specifications ...................................................................... D-1
Notes
SUPERSERVER 6022C User's Manual
x
Chapter 1
Introduction to the SuperServer 6022C
1-1 Overview
The Supermicro SuperServer 6022C is a high-end, dual Xeon 2U rackmount server that features some of the most advanced technology currently avail­able. The SuperServer 6022C is comprised of two main subsystems: the SC822R-400LP 2U rackmount chassis and the P4DC6+; a dual Xeon proces­sor mainboard based on Intel's 860 chipset. Please refer to our web site for information on operating systems that have been certified for use with the SuperServer 6022C. (www.supermicro.com)
In addition to the mainboard and chassis, various hardware components may have been included with your SuperServer 6022C, as listed below:
l Up to two (2) 603-pin Xeon (Foster) processors*
l Two (2) CPU heat sinks* (SNK-030)
l Up to 2 GB 600/800 MHz RDRAM main memory*
l One (1) 1.44" floppy drive
l One (1) slim CD-ROM drive
l One (1) 5.25" drive bay
l One (1) SCA SCSI backplane
l Six (6) SCA 1-inch high SCSI drive carriers
l One (1) 8 MB low profile ATI Rage graphics card (PCI)
l SCSI Accessories
One (1) internal 68-pin Ultra160 SCSI cable for SCA SCSI backplane
One (1) set of SCSI driver diskettes
One (1) SCSI manual
Chapter 1: Introduction
1-1
SUPERSERVER 6022C User's Manual
1-2
1-2 Server Chassis Features
The SuperServer 6022C is a high-end, scaleable 2U rackmount server plat­form designed with today's most state-of-the-art features. The following is a general outline of the main features of the SC822 chassis.
System Power
When configured as a SuperSever 6022CF, the SC822 chassis includes a 400W power supply.
SCSI Subsystem
The SCSI subsystem supports two 80-pin SCA Ultra160 SCSI hard drives. (Any standard 1" drives are supported. SCA = Single Connection Attach­ment.) The SCSI drives are connected to an SCA backplane that provides power, bus termination and configuration settings. The SCSI drives are also hot-swap units.
Control Panel
The SC822's control panel provides important system monitoring and control information. LEDs indicate power on, network activity, hard disk drive ac­tivity and system overheat conditions. The control panel also includes a main power button and a system reset button.
l Rackmount hardware (with screws):
Two (2) rack rail assemblies Six (6) brackets for mounting the rack rails to a rack/telco rack
l One (1) CD-ROM containing drivers and utilities:
Intel LANDesk Client Manager ATI Rage graphics controller driver LAN driver SCSI driver
l SuperServer 6022C User's Manual
*
Type and number depends upon the configuration ordered.
1-3
Chapter 1: Introduction
I/O Shield
The SC822 is a 2U rackmount chassis. Its I/O shield provides seven moth­erboard low profile expansion slots, two COM ports, two USB ports, PS/2 mouse and keyboard ports, sound ports and one Ethernet port. See Figure 1-1 for locations.
Cooling System
The SC822 chassis has an innovative cooling design that includes four 8­cm redundant system cooling (intake) fans. The fans plug into chassis fan connectors that are located behind the HDD drive bays. These fans run continuously at full rpm. If they break down, the ambient air temperature inside the chassis will rise and activate an overheat LED.
Figure 1-1. I/O Backpanel
SUPERSERVER 6022C User's Manual
1-4
1-3 Mainboard Features
At the heart of the SuperServer 6022C lies the P4DC6+, a dual processor motherboard designed to provide maximum performance. Below are the main features of the P4DC6+.
Chipset
The P4DC6+ is based on the Intel 860 chipset, which is a high-performance core logic chipset that consists of three major components: the Memory Controller Hub (MCH), the P64H and the I/O Controller Hub 2 (ICH2).
The MCH is optimized to provide superior performance between single or dual Xeon CPUs and the dual channel RDRAM memory, which operates at up to 3.2 GB/s data bus bandwidth.
The P64H provides support for two PCI-64 slots and two SCSI hard disk drive channels. It interfaces directly with the MCH.
The ICH2 is a highly integrated multifunctional I/O Controller Hub that pro­vides the interface to the PCI Bus and integrates many of the functions needed in today’s server platforms.
Processors
The P4DC6+ supports single or dual Xeon Foster 1.5-2.4+ GHz processors at a 400 MHz front side bus speed. Please refer to the support section of our web site for a complete listing of supported processors (http:// www.supermicro.com/TechSupport.htm).
Memory
The P4DC6+ has 4 (four) 184-pin RIMM slots that can support up to 2 GB of 600 or 800 MHz RDRAM. Module sizes of 64 MB, 128 MB, 256 MB and 512 MB may be used to populate the RIMM slots.
Onboard SCSI
Onboard SCSI is provided with an Adaptec AIC-7899W SCSI controller chip, which supports dual channel, Ultra160 SCSI at a burst throughput rate of 160 MB/sec.
1-5
Chapter 1: Introduction
PCI Expansion Slots
The P4DC6+ has two 64-bit 66/33 MHz and four 64-bit 33 MHz PCI slots.
ATI Graphics Controller
The P4DC6+ includes an 8 MB PCI ATI Rage XL low profile video graphics card. The Rage XL fully supports sideband addressing. This graphics package provides a bandwidth of up to 512 MB/sec over a 32-bit graphics memory bus.
Onboard Controllers/Ports
One floppy drive controller and two onboard IDE controllers support one up to four hard drives or ATAPI devices. Onboard I/O ports include two COM ports, two USB ports, PS/2 mouse and keyboard ports, a parallel (printer) port, sound ports and a 10/100 MB Intel 82559 Ethernet (NIC) port.
Other Features
Other onboard features that promote system health include five voltage monitors, two CPU temperature sensors, four fan speed sensors, a chas­sis intrusion header, auto-switching voltage regulators, chassis and CPU overheat sensors, virus protection and BIOS rescue.
SUPERSERVER 6022C User's Manual
1-6
1-4 Contacting Supermicro
Headquarters
Address: Super Micro Computer, Inc.
980 Rock Ave.
San Jose, CA 95131 U.S.A. Tel: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: marketing@supermicro.com (General Information)
support@supermicro.com (Technical Support) Web Site: www.supermicro.com
Europe
Address: Super Micro Computer B.V.
Het Sterrenbeeld 28, 5215 ML
's-Hertogenbosch, The Netherlands Tel: +31 (0) 73-6400390 Fax: +31 (0) 73-6416525 Email: sales@supermicro.nl (General Information)
support@supermicro.nl (Technical Support)
rma@supermicro.nl (Customer Support)
Asia-Pacific
Address: 3F, #753 Chung-Cheng Road
Chung-Ho City, Taipei Hsien, Taiwan, R.O.C. Tel: +886-(2) 8228-1366 Fax: +886-(2) 8221-2790 Web Site: www.supermicro.com.tw Technical Support: Email: support@supermicro.com.tw Tel : 886-2-8228-1366, ext.132
Chapter 2: Server Installation
2-1
Chapter 2
Server Installation
2-1 Overview
This chapter provides a quick setup checklist to get your SuperServer 6022C up and running. Following these steps in the order given should enable you to have the system operational within a minimum amount of time. This quick setup assumes that your SuperServer 6022C system has come to you with the processors and memory preinstalled. If your system is not already fully integrated with a motherboard, processors, system memory etc., please turn to the chapter or section noted in each step for details on installing specific components.
2-2 Unpacking the SuperServer 6022C
You should inspect the box the SuperServer 6022C was shipped in and note if it was damaged in any way. If the server itself shows damage you should file a damage claim with the carrier who delivered it.
Decide on a suitable location for the rack unit that will hold the SuperServer 6022C. It should be situated in a clean, dust-free area that is well ventilated. Avoid areas where heat, electrical noise and electromagnetic fields are generated. You will also need it placed near a grounded power outlet. Read the Rack and Server Precautions in the next section.
2-3 Preparing for Setup
The box the SuperServer 6022C was shipped in should include two sets of rail assemblies, two rail mounting brackets and the mounting screws you will need to install the system into the rack. Follow the steps in the order given to complete the installation process in a minimum amount of time. Please read this section in its entirety before you begin the installation procedure outlined in the sections that follow.
2-2
SUPERSERVER 6022C User's Manual
Choosing a Setup Location
- Leave enough clearance in front of the rack to enable you to open
the front door completely (~25 inches).
- Leave approximately 30 inches of clearance in the back of the rack
to allow for sufficient airflow and ease in servicing.
Rack Precautions
- Ensure that the leveling jacks on the bottom of the rack are fully
extended to the floor with the full weight of the rack resting on them.
- In single rack installation, stabilizers should be attached to the rack.
- In multiple rack installations, the racks should be coupled together.
- Always make sure the rack is stable before extending a component
from the rack.
- You should extend only one component at a time - extending two or
more simultaneously may cause the rack to become unstable.
Server Precautions
- Review the electrical and general safety precautions in Chapter 4.
- Determine the placement of each component in the rack
before
you
install the rails.
- Install the heaviest server components on the bottom of the rack
first, and then work up.
- Use a regulating uninterruptible power supply (UPS) to protect the server from power surges, voltage spikes and to keep your system operating in case of a power failure.
- Allow the hot plug SCSI drives and power supply units to cool before
touching them.
- Always keep the rack's front door and all panels and components on
the servers closed when not servicing to maintain proper cooling.
! !
Warnings and Precautions!
Chapter 2: Server Installation
2-3
2-4 Installing the SuperServer 6022C into a Rack
This section provides information on installing the SuperServer 6022C into a rack unit. If the 6022C has already been mounted into a rack, you can skip ahead to Sections 2-5 and 2-6. There are a variety of rack units on the market, which may mean the assembly procedure will differ slightly. The following is a guideline for installing the 6022C into a rack with the rack rails provided. You should also refer to the installation instructions that came with the rack unit you are using.
Identifying the Sections of the Rack Rails
You should have received two rack rail assemblies with the SuperServer 6022C. Each of these assemblies consist of three sections: an inner fixed chassis rail that secures to the 6022C (A) and an outer fixed rack rail that secures directly to the rack itself (B). A sliding rail guide sandwiched between the two should remain attached to the fixed rack rail. (See Figure 2-1.) The A and B rails must be detached from each other to install.
To remove the fixed chassis rail (A), pull it out as far as possible - you should hear a "click" sound as a locking tab emerges from inside the rail assembly and locks the inner rail. Then depress the locking tab to pull the inner rail completely out. Do this for both the left and right side rack rail assemblies.
Figure 2-1. Identifying the Sections of the Rack Rails
A
B
2-4
SUPERSERVER 6022C User's Manual
Installing the Chassis Rails
Remove the handles on the 6022C chassis (see Figure 2-1) and position the fixed chassis rail sections along the side of the 6022C chassis making sure the two screw holes line up. Note that these two rails are left/right spe cific. Slide the rails on to the hooks on both sides of the chassis. Screw the rail securely to the side of the chassis, and then reinstall the chassis handle (see Figure 2-2). Repeat this procedure for the other rail on the other side of the chassis. You will also need to attach the rail brackets when installing into a telco rack.
Locking Tabs: As you have seen, both chassis rails have a locking tab, which serves two functions. The first is to lock the server into place when installed and pushed fully into the rack, which is its normal position. Secondly, these tabs also lock the server in place when fully extended from the rack. This prevents the server from coming completely out of the rack when you pull it out for servicing.
Figure 2-2. Installing Chassis Rails
Installing the Rack Rails
Determine where you want to place the SuperServer 6022C in the rack. (See Rack and Server Precautions in Section 2-3.) Position the fixed rack rail/sliding rail guide assemblies at the desired location in the rack, keeping the sliding rail guide facing the inside of the rack. Screw the assembly securely to the rack using the brackets provided. Attach the
Chapter 2: Server Installation
2-5
Figure 2-3. Installing the Server into a Rack
Installing the Server into the Rack
You should now have rails attached to both the chassis and the rack unit. The next step is to install the server into the chassis. Do this by lining up the rear of the chassis rails with the front of the rack rails. Slide the chassis rails into the rack rails, keeping the pressure even on both sides (you may have to depress the locking tabs when inserting). See Figure 2-3.
When the server has been pushed completely into the rack, you should hear the locking tabs "click". Finish by inserting and tightening the thumbscrews that hold the front of the server to the rack.
other assembly to the other side of the rack, making both are at the exact same height and with the rail guides facing inward.
2-6
SUPERSERVER 6022C User's Manual
Figure 2-4. Installing the Server into a Telco Rack
Installing the Server into a Telco Rack
If you are installing the SuperServer 6022C into a Telco type rack, follow the directions given on the previous pages for rack installation. The only difference in the installation procedure will be the positioning of the rack brackets to the rack. They should be spaced apart just enough to accomodate the width of the telco rack.
Chapter 2: Server Installation
2-7
2-5 Checking the Motherboard Setup
After you install the 6022C in the rack, you will need to open the unit to make sure the motherboard is properly installed and all the connections have been made.
1. Accessing the inside of the 6022C (see Figure 2-5):
First, release the retention screws that secure the unit to the rack. Grasp the two handles on either side and pull the unit straight out until it locks (you will hear a "click"). Next, depress the two buttons on the top of the chassis to release the top cover. There is a large rectangular recess in the middle front of the top cover to help you push the cover away from you until it stops. You can then lift the top cover from the chassis to gain full access to the inside of the server.
2. Check the CPUs (processors):
You should have one or two processors already installed into the system board. Each processor should have its own heatsink attached. See Section 5-5 for instructions on processor installation.
3. Check the system memory:
Your 6022C server system may have come with system memory already installed. Make sure all RIMMs are fully seated in their slots. For details on adding system memory, refer to Section 5-6.
4. Installing add-on cards:
If desired, you can install low profile add-on cards to the system. See Section 5-7 for details on installing PCI add-on cards.
5. Check all cable connections and airflow:
Make sure all power and data cables are properly connected and not blocking the airflow. See Section 5-3 for details on cable connections. Also, check the air seals for damage. The air seals are located under the blower fan and beneath the frame cross section that separates the drive bay area from the motherboard area of the chassis.
2-8
SUPERSERVER 6022C User's Manual
Figure 2-5. Accessing the Inside of the SuperServer 6022C
(with one SCSI Drive removed)
Chapter 2: Server Installation
2-9
2-6 Checking the Drive Bay Setup
Next, you should check to make sure the peripheral drives, the SCSI drives and SCA backplane have been properly installed and all connections have been made.
1. Accessing the drive bays:
All drives can be accessed from the front of the server. For servicing the CD-ROM and floppy drives, you will need to remove the top chassis cover. The SCSI disk drives can be installed and removed from the front of the chassis without removing the top chassis cover. The 5.25" drive bay cover can be removed by pressing the tab on the corner of the drive bay and then pushing the bay outward from the inside.
2. Check the SCSI disk drives:
Depending upon your system's configuration, your system may have one or more SCSI drive already installed. If you need to install additional SCSI drives, please refer to Section 6-4.
3. Installing components into the 5.25" drive bay:
Refer to Section 6-4 if you wish to install a component into the 5.25" drive bay.
4. Reinstalling a CD-ROM and/or floppy disk drives:
Refer to Section 6-4 if you need to reinstall a CD-ROM and/or floppy disk drive to the system.
2-10
SUPERSERVER 6022C User's Manual
2-7 Checking the System Airflow
Airflow is provided by four 8-cm redundant cooling fans. The system com­ponent layout was carefully designed to promote sufficient airflow through the 2U rackmount space. Note that all power and data cables have been routed in such a way that they do not block the airflow generated by the fans.
2-8 Supplying Power to the System
The last thing you must do is to provide input power to the system. Plug the power cord from the power supply unit into a high-quality power strip that offers protection from electrical noise and power surges. It is recommended that you use an uninterruptible power supply (UPS) source. Finally, depress the power button on the front of the chassis to apply power and boot the system.
Chapter 3: System Interface
3-1
Chapter 3
System Interface
3-1 Overview
There are several LEDs on the control panel as well as others on the SCSI drive carriers and the motherboard to keep you constantly informed of the overall status of the system as well as the activity and health of specific components. There are also two buttons on the chassis control panel and an on/off switch on the power supply. This chapter explains the meanings of all LED indicators and the appropriate response you may need to take.
3-2 Control Panel Buttons
There are two push-button buttons located on the front of the chassis. These are (in order from left to right) a reset button and a power on/off button.
l RESET: The reset switch reboots the system.
l POWER: This is the main power switch, which is used to apply or
turn off the main system power. Turning off system power with this button removes the main power but keeps standby power supplied to the system. (See also the power supply on/off switch in Section 3-5.)
SUPERSERVER 6022C User's Manual
3-2
3-3 Control Panel LEDs
The control panel located on the front of the SC822 chassis has five LEDs. These LEDs provide you with critical information related to different parts of the system. This section explains what each LED indicates when illumi­nated and any corrective action you may need to take.
l Overheat: Indicates an overheat condition in the chassis. This may be caused by cables obstructing the airflow in the system, or the ambient room temperature being too warm. You should also check to make sure that the chassis cover is installed and that all fans are present and operat­ing normally. Make certain that the heat sinks are installed properly (see section 5-5 and figure 5-4) and make certain that the chassis top cover is in place durning server operation to assure proper cooling air circulation.
l NIC: Indicates network activity on the LAN when flashing.
l HDD: Indicates IDE channel activity. On the SuperServer 6022C, this
light indicates CD-ROM drive activity when flashing.
NIC
Chapter 3: System Interface
3-3
l Power: Indicates power is being supplied to the system's power
supply units. This LED should normally be illuminated when the system is operating.
3-4 SCSI Drive Carrier LEDs
A SCSI drive carrier has two LEDs.
l Green: When illuminated, the green LED on the front of the SCSI drive
carrier indicates drive activity. A connection to the SCSI SCA backplane enables this LED to blink on and off when that particular drive is being accessed.
l Red: A SAF-TE compliant backplane is needed to activate the red LED to indicate a drive failure. (A SAF-TE compliant SCSI backplane is optional on the 6022C.) If one of the SCSI drives fail, you should be notified by your system management software. Please refer to Section 6-4 for instructions on replacing failed SCSI drives.
3-5 Motherboard LED
There is only one LED on the motherboard. When illuminated, it indicates that system power is present on the motherboard. This LED is located in near the floppy connector.
SUPERSERVER 6022C User's Manual
3-4
Notes