The information in this User’s Manual has been carefully reviewed and is believed to be accurate.
The vendor assumes no responsibility for any inaccuracies that may be contained in this document,
makes no commitment to update or to keep current the information in this manual, or to notify any
person or organization of the updates. Please Note: For the most up-to-date version of this
manual, please see our web site at www.supermicro.com.
Super Micro Computer, Inc. ("Supermicro") reserves the right to make changes to the product
described in this manual at any time and without notice. This product, including software and documentation, is the property of Supermicro and/or its licensors, and is supplied only under a license.
Any use or reproduction of this product is not allowed, except as expressly permitted by the terms
of said license.
IN NO EVENT WILL SUPERMICRO BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL,
SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO
USE THIS PRODUCT OR DOCUMENTATION, EVEN IF ADVISED OF THE POSSIBILITY OF
SUCH DAMAGES. IN PARTICULAR, SUPERMICRO SHALL NOT HAVE LIABILITY FOR ANY
HARDWARE, SOFTW ARE, OR DA TA STORED OR USED WITH THE PRODUCT, INCLUDING THE
COSTS OF REPAIRING, REPLACING, INTEGRATING, INSTALLING OR RECOVERING SUCH
HARDWARE, SOFTWARE, OR DATA.
Any disputes arising between manufacturer and customer shall be governed by the laws of Santa
Clara County in the State of California, USA. The State of California, County of Santa Clara shall
be the exclusive venue for the resolution of any such disputes. Super Micro's total liability for all
claims will not exceed the price paid for the hardware product.
FCC Statement: This equipment has been tested and found to comply with the limits for a Class A
digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the manufacturer’s instruction manual, may cause harmful interference
with radio communications. Operation of this equipment in a residential area is likely to cause harmful
interference, in which case you will be required to correct the interference at your own expense.
California Best Management Practices Regulations for Perchlorate Materials: This Perchlorate warning applies only to products containing CR (Manganese Dioxide) Lithium coin cells. “Perchlorate
Material-special handling may apply. See www.dtsc.ca.gov/hazardouswaste/perchlorate”
WARNING: Handling of lead solder materials used in this
product may expose you to lead, a chemical known to the
State of California to cause birth defects and other reproductive harm.
Manual Revision 1.0a
Release Date: February 4, 2013
Unless you request and receive written permission from Super Micro Computer, Inc., you may not
copy any part of this document.
Information in this document is subject to change without notice. Other products and companies
referred to herein are trademarks or registered trademarks of their respective companies or mark
holders.
This manual is written for professional system integrators and PC technicians.
It provides information for the installation and use of the SuperServer 6016TURF4+/6016T-NTRF4+. Installation and maintenance should be performed by
experienced technicians only.
Manual Organization
Chapter 1: Introduction
The fi rst chapter provides a checklist of the main components included with the
server system and describes the main features of the X8DTU-LN4F+ serverboard
and the SC819TQ-R700U chassis, which comprise the SuperServer 6016TURF4+/6016T-NTRF4+.
Preface
Chapter 2: Server Installation
This chapter describes the steps necessary to install the SuperServer into a rack and
check out the server confi guration prior to powering up the system. If your server
was ordered without processor and memory components, this chapter will refer you
to the appropriate sections of the manual for their installation.
Chapter 3: System Interface
Refer here for details on the system interface, which includes the functions and
information provided by the control panel on the chassis as well as other LEDs
located throughout the system.
Chapter 4: System Safety
You should thoroughly familiarize yourself with this chapter for a general overview
of safety precautions that should be followed when installing and servicing the
SuperServer 6016T-URF4+/6016T-NTRF4+.
Chapter 5 provides detailed information on the X8DTU-LN4F+ serverboard, including the locations and functions of connections, headers and jumpers. Refer to this
chapter when adding or removing processors or main memory and when reconfi g-
uring the serverboard.
Chapter 6: Advanced Chassis Setup
Refer to Chapter 6 for detailed information on the SC819TQ-R700U server chassis.
You should follow the procedures given in this chapter when installing, removing or
reconfi guring SATA or peripheral drives and when replacing system power supply
modules and cooling fans.
Chapter 7: BIOS
The BIOS chapter includes an introduction to BIOS and provides detailed information on running the CMOS Setup Utility.
Appendix A BIOS Error Beep Codes
Appendix B System Specifi cations
viii
Chapter 1: Introduction
Chapter 1
Introduction
1-1 Overview
The SuperServer 6016T-URF4+/NTRF4+ is a high-end server comprised of two
main subsystems: the SC819TQ-R700U 1U server chassis and the X8DTU-LN4F+
dual processor serverboard. Please refer to our web site for information on operating
systems that have been certifi ed for use with the system (www.supermicro.com).
In addition to the serverboard and chassis, various hardware components have been
included with the 6016T-URF4+/6016T-NTRF4+, as listed below:
• One slim DVD-ROM drive (DVM-TEAC-SBT)
• One internal USB cable for DVD-ROM (CBL-0341L)
• One mini SATA to USB adapter for DVD-ROM drive (CDM-USATA-G)
• Five sets of 4-cm counter-rotating fans (FAN-0086L4)
• One air shroud (MCP-310-81901-0B)
• Two passive CPU heatsinks (SNK-P0037P)
• Riser Cards: (see Section 5-6 for details)
One RSC-R1UU-E8R+ and one RSC-R1UU-UE16
• SATA Accessories
One SATA backplane (BPN-SAS-815TQ)
One SAS cable (CBL-0343L, 6016T-URF4+ only)
Four SATA drive carriers (MCP-220-00001-01)
One SATA cable set (CBL-0190L) (6016T-NTRF4+ only)
One SGPIO cable (CBL-0157) (6016T-NTRF4+ only)
At the heart of the SuperServer 6016T-URF4+/6016T-NTRF4+ lies the X8DTULN4F+, a dual processor serverboard based on the Intel® 5520 + ICH10R chipset.
Below are the main features of the X8DTU-LN4F+. (See Figure 1-1 for a block
diagram of the chipset).
Processors
The X8DTU-LN4F+ supports single or dual Intel® 5500/5600 Series processors in
LGA1366 sockets. Please refer to our web site for a complete listing of supported
processors (www.supermicro.com).
Memory
The X8DTU-LN4F+ features 240-pin DIMM sockets that can support up to 192 GB
of registered ECC DDR3-1333/1066/800 or 48 GB of unbuffered ECC/non-ECC
DDR3-1333/1066/800 SDRAM. Please refer to Chapter 5 for installing memory.
UIO
The X8DTU-LN4F+ is a specially-designed serverboard that features Supermicro's
UIO (Uni ve rsal I/O) tec h n o l ogy. UIO serverbo a r d s h ave a P CI Express 2.0 x8 s lot
that can s upport a ny one of several ty pes of UIO car d types to ad d SAS port s,
SATA ports, ad d i tional LAN port s or other addi tional f u n ctions to t he serverboa r d.
This all ows the u ser to ta ilor th e ser verb oard to t heir ow n needs.
Note: the ser ver does n ot com e with a UI O card i nstal led.
Serial ATA
An on-chip (ICH10R) SATA controller is integrated into the X8DTU-LN4F+ to
provide a six-port, 3 Gb/sec SATA subsystem, which is RAID 0, 1, 5 and 10
suppor ted (RAID 5 is suppor ted with Windows OS only). The SATA drives are
hot-swappable units.
Note: You must have RAID set up to enable the hot-swap capability of the SATA
drives. D ocum entati on on R AI D setup gui deline s can be fo und on our we b site.
Onboard Controllers/Ports
The color-coded I/O ports include one COM port, a VGA (monitor) port, two USB
2.0 ports, PS/2 mouse and keyboard ports, one dedicated IPMI LAN port and four
gigabit Ethernet ports.
1-2
Chapter 1: Introduction
Graphics Controller
The X8DTU-LN4F+ features an integrated Matrox G200eW graphics chip, which
includes 16 MB of DDR2 memory.
Other Features
Other onboard features that promote system health include onboard voltage monitors, auto-switching voltage regulators, chassis and CPU overheat sensors, virus
protection and BIOS rescue.
1-3 Server Chassis Features
The 6016T-URF4+/6016T-NTRF4+ is built upon the SC819TQ-R700U chassis.
Details on the chassis and on servicing procedures can be found in Chapter 6.The
following is a general outline of the main features of the chassis.
System Power
The SC819TQ-R700U features a redundant 700W power supply consisting of two
power modules. The system does not need to be shut down when replacing or
removing a single power supply module.
SAS/SATA Subsystem
The SC819TQ-R700U c ha ss is was d es ig ne d to su pp ort fou r hot - swa p SAS /S ATA
hard drives.
PCI Expansion Slots
Two riser cards are included. The RSC-R1UU-E8R+ is located on the right side of
the chassis and supports one low- profi le (5.5" l ength) PCI- E x8 card. The RSC-
R1UU-UE16 is located on the left side of the chassis and supports one UIO card and
one PCI -E x16 add -on ca rd. See our web site for details (http://www.supermicro.
com/products/nfo/UIO.cfm). See section 5-6 of this manual for details.
Front Control Panel
The chassis' control panel provides you with system monitoring and control. LEDs
indicate system power, HDD activity, network activity (2), overheat/fan/power failure
and UID (Unit Identifi er). A main power button and a UID button is also included.
The SC819TQ-R700U has an innovative cooling design that features fi ve sets
of 4-cm counter-rotating fans located in the middle section of the chassis. There
is a "Fan Speed Control Mode" setting in BIOS that allows chassis fan speed to
be determined by system temperature. The power supply module also includes a
cooling fan.
1-4
Chapter 1: Introduction
Figure 1-1. Intel IOH-36D/ICH10R Chipset:
System Block Diagram
Note: This is a general block diagram. Please see Chapter 5 for details.
This chapter provides a quick setup checklist to get your 6016T-URF4+/6016TNTRF4+ up and running. Following these steps in the order given should enable
you to have the system operational within a minimum amount of time. This quick
setup assumes that your system has come to you with the processors and memory
pre-installed. If your system is not already fully integrated with a serverboard, processors, system memory etc., please turn to the chapter or section noted in each
step for details on installing specifi c components.
2-2 Unpacking the System
You should inspect the box the 6016T-URF4+/6016T-NTRF4+ was shipped in and
note if it was damaged in any way. If the server itself shows damage you should
fi le a damage claim with the carrier who delivered it.
Decide on a suitable location for the rack unit that will hold the 6016T-URF4+/6016T NTRF4+. It should be situated in a clean, dust-free area that is well ventilated. A void
areas where heat, electrical noise and electromagnetic fi elds are generated. You
will also need it placed near a grounded power outlet. Be sure to read the Rack
and Server Precautions in the next section.
2-3 Preparing for Setup
The box the 6016T-URF4+/6016T-NTRF4+ was shipped in should include two
sets of rail assemblies, two rail mounting brackets and the mounting screws you
will need to install the system into the rack. Follow the steps in the order given to
complete the installation process in a minimum amount of time. Please read this
section in its entirety before you begin the installation procedure outlined in the
sections that follow.
Choosing a Setup Location
• Leave enough clearance in front of the rack to enable you to open the front door
completely (~25 inches) and approximately 30 inches of clearance in the back
of the rack to allow for suffi cient airfl ow and ease in servicing.This product is for
installation only in a Restricted Access Location (dedicated equipment rooms,
service closets and the like).
• This product is not suitable for use with visual display work place devices
acccording to §2 of the the German Ordinance for Work with Visual Display Units.
2-4 Warnings and Precautions
Rack Precautions
• Ensure that the leveling jacks on the bottom of the rack are fully extended to
the fl oor with the full weight of the rack resting on them.
• In single rack installation, stabilizers should be attached to the rack. In multiple
rack installations, the racks should be coupled together.
• Always make sure the rack is stable before extending a component from the
rack.
• You should extend only one component at a time - extending two or more si-
multaneously may cause the rack to become unstable.
Server Precautions
• Review the electrical and general safety precautions in Chapter 4.
• Determine the placement of each component in the rack before you install the
rails.
• Install the heaviest server components on the bottom of the rack fi rst, and then
work up.
• Use a regulating uninterruptible power supply (UPS) to protect the server from
power surges, voltage spikes and to keep your system operating in case of a
power failure.
• Allow the hot plug SAS/SATA drives and power supply modules to cool before
touching them.
• Always keep the rack's front door and all panels and components on the servers
closed when not servicing to maintain proper cooling.
2-2
Chapter 2: Server Installation
Rack Mounting Considerations
Ambient Operating Temperature
If installed in a closed or multi-unit rack assembly, the ambient operating temperature of the rack environment may be greater than the ambient temperature of the
room. Therefore, consideration should be given to installing the equipment in an
environment compatible with the manufacturer’s maximum rated ambient temperature (Tmra).
Reduced Airfl ow
Equipment should be mounted into a rack so that the amount of airfl ow required
for safe operation is not compromised.
Mechanical Loading
Equipment should be mounted into a rack so that a hazardous condition does not
arise due to uneven mechanical loading.
Circuit Overloading
Consideration should be given to the connection of the equipment to the power
supply circuitry and the effect that any possible overloading of circuits might have
on overcurrent protection and power supply wiring. Appropriate consideration of
equipment nameplate ratings should be used when addressing this concern.
Reliable Ground
A reliable ground must be maintained at all times. To ensure this, the rack itself
should be grounded. Particular attention should be given to power supply connections other than the direct connections to the branch circuit (i.e. the use of power
strips, etc.).
Warning! To prevent bodily injury when mounting or servicing this unit in a
rack, you must take special precautions to ensure that the system remains
stable. The following guidelines are provided to ensure your safety:
• This unit should be mounted at the bottom of the rack if it is the only unit in
the rack.
• When mounting this unit in a partially fi lled rack, load the rack from the bottom
to the top with the heaviest component at the bottom of the rack.
• If the rack is provided with stabilizing devices, install the stabilizers before
This section provides information on installing the 6016T-URF4+/6016T-NTRF4+
into a rack unit with the rack rails provided. If the system has already been mounted
into a rack, you can skip ahead to Sections 2-5 and 2-6. There are a variety of rack
units on the market, which may mean the assembly procedure will differ slightly.
You should also refer to the installation instructions that came with the rack unit
you are using.
Identifying the Sections of the Rack Rails
You should have received two rack rail assemblies in the rack mounting kit. Each
assembly consists of two sections: an inner fi xed chassis rail that secures directly
to the server chassis and an outer fi xed rack rail that secures directly to the rack
itself (see Figure 2-1). Two pairs of short brackets to be used on the front side of
the outer rails are also included.
Installing the Inner Rails
Both the left and right side inner rails have been pre-attached to the chassis. Proceed to the next step.
Figure 2-1. Identifying the Sections of the Rack Rails
(left side rail shown)
Inner RailOuter RailLocking Tab
Warning: do not pick up the server with the front handles. They are de-
signed to pull the system from a rack only.
2-4
Chapter 2: Server Installation
Installing the Outer Rails
Installing the Outer Rails to the Rack
1. Measure the distance from the front rail to the rear rail of the rack.
2. Attach a short bracket to the front side of the right outer rail and a long
bracket to the rear side of the right outer rail.
3. Adjust both the short and long brackets to the proper distance so that the rail
can fi t snugly into the rack.
4. Secure the short bracket to the front side of the outer rail with two M4 screws
and the long bracket to the rear side of the outer rail with three M4 screws.
5. Repeat these steps for the left outer rail.
Locking Tabs
Both chassis rails have a locking tab, which serves two functions. The fi rst is to
lock the server into place when installed and pushed fully into the rack, which is
its normal position. Secondly, these tabs also lock the server in place when fully
extended from the rack. This prevents the server from coming completely out of the
rack when you pull it out for servicing.
1. Confi rm that chassis includes the inner rails and rail extensions . Also, confi rm
that the outer rails are installed on the rack.
2. Line chassis rails with the front of the rack rails.
3. Slide the chassis rails into the rack rails, keeping the pressure even on both
sides (you may have to depress the locking tabs when inserting). When the
server has been pushed completely into the rack, you should hear the locking
tabs "click".
4. (Optional) Insert and tightening the thumbscrews that hold the front of the
server to the rack.
Installing the Server into a Telco Rack
T o install the 6016T -URF4+/6016T -NTRF4+ into a Telco type rack, use two L-shaped
brackets on either side of the chassis (four total). First, determine how far follow the
server will extend out the front of the rack. Larger chassis should be positioned to
balance the weight between front and back. If a bezel is included on your server,
remove it. Then attach the two front brackets to each side of the chassis, then the
two rear brackets positioned with just enough space to accommodate the width of
the telco rack. Finish by sliding the chassis into the rack and tightening the brackets
to the rack.
Stability hazard. The rack stabilizing mechanism must be in place, or the
rack must be bolted to the fl oor before you slide the unit out for servicing.
Failure to stabilize the rack can cause the rack to tip over.
After you install the system in the rack, you will need to open the top cover to
make sure the serverboard is properly installed and all the connections have been
made.
Accessing the Inside of the System
1. First, grasp the two handles on either side and pull the system straight out
until it locks (you will hear a "click").
2. Next, release the thumbscrew at the middle rear of the top cover. Then press
the two buttons on the top of the chassis to release the top cover.
3. Push the cover away from you (toward the rear of the chassis) until it stops.
You can then lift the top cover from the chassis to gain full access to the
inside of the server.
4. To remove the system from the rack completely, press the locking tabs in
the chassis rails (push the right-side tab down and the left-side tab up) to
continue to pull the system out past the locked position.
Checking the Components
1. You may have one or two processors already installed in the serverboard.
Each processor needs its own heatsink. See Chapter 5 for instructions on
processor and heatsink installation.
2. Your server system may have come with system memory already installed.
Make sure all DIMMs are fully seated in their slots. For details on adding
system memory, refer to Chapter 5.
3. If desired, you can install an add-on card to the system. See Chapter 5 for
details on installing PCI add-on cards.
4. Make sure all power and data cables are properly connected and not blocking
the chassis airfl ow. See Chapter 5 for details on cable connections.
Next, you should check to make sure the peripheral drives and the hard drives and
backplane have been properly installed and all connections have been made.
Checking the Drives
1. All drives are accessable from the front of the server. The hard disk drives
can be installed and removed from the front of the chassis without removing
the top chassis cover.
2. A slim DVD-ROM drive should be preinstalled in your server. For servicing
the DVD-ROM drive, you will need to remove the top chassis cover. Refer to
Chapter 6 if you need to reinstall a DVD-ROM drive to the system.
3. Depending upon your system's confi guration, your system may have one or
more drives already installed. If you need to install hard drives, please refer to
Chapter 6.
Checking the Airfl ow
1. Airfl ow is provided by fi ve sets of 4-cm fans (each set of fans consists of
two fans that are mounted back to back). The system component layout was
carefully designed to direct suffi cient cooling airfl ow to the components that
generate the most heat.
2. Note that all power and data cables have been routed in such a way that they
do not block the airfl ow generated by the fans.
Providing Power
1. The last thing you must do is to provide input power to the system. Plug the
power cord from the power supply module into a high-quality power strip that
offers protection from electrical noise and power surges.
2. It is recommended that you use an uninterruptible power supply (UPS)
source.
2-10
Chapter 3: System Interface
Chapter 3
System Interface
3-1 Overview
There are several LEDs on the control panel as well as others on the hard drive
carriers to keep you constantly informed of the overall status of the system as well
as the activity and health of specifi c components. There are also two buttons on
the chassis control panel and an on/off switch on the power supply. This chapter
explains the meanings of all LED indicators and the appropriate response you may
need to take.
3-2 Control Panel Buttons
There are three push-buttons located on the front of the chassis. These are (in order
from left to right) A UID button, a reset button and a power on/off button.
UID
Depressing the UID (unit identifi er) button illuminates an LED on both the front and
rear of the chassis for easy system location in large stack confi gurations. The LED
will remain on until the button is pushed a second time. Another UID button on the
rear of the chassis serves the same function.
Reset
The reset button reboots the system.
Power
The main power switch is used to apply or remove power from the power supply
to the server system. Turning off system power with this button removes the main
power but keeps standby power supplied to the system.
The control panel located on the front of the SC819TQ chassis has fi ve LEDs. These
LEDs provide you with critical information related to different parts of the system.
This section explains what each LED indicates when illuminated and any corrective
action you may need to take.
UID/Overheat/Fan Fail/Power Fail
Blue: This LED turns on when either the front or the rear UID button is pushed.
Pushing either button a second time will turn this LED off.
Red: When this LED fl ashes it indicates a fan failure. When on continuously (on and
not fl ashing) it indicates an overheat condition, which may be caused by cables ob-
structing the airfl ow in the system or the ambient room temperature being too warm.
Check the routing of the cables and make sure all fans are present and operating
normally. You should also check to make sure that the chassis covers are installed.
Finally, verify that the heatsinks are installed properly (see Chapter 5). This LED
will remain fl ashing or on as long as the overheat condition exists.
2
NIC2
Indicates network activity on GLAN2 when fl ashing .
1
NIC1
Indicates network activity on GLAN1 when fl ashing.
HDD
Indicates IDE channel activity. On the 6016T-URF4+/6016T-NTRF4+ this light indicates HDD and/or DVD-ROM drive activity when fl ashing.
3-2
Chapter 3: System Interface
Power
Indicates power is being supplied to the system's power supply units. This LED
should normally be illuminated when the system is operating.
3-4 Drive Carrier LEDs
Green: Each SAS /SATA dr ive ca rri er has a gr een LED. Whe n illumi nated,
this gre en LED in dic ates dr ive ac tiv it y. A connec tio n to the S AS/ SATA b ack plan e
enable s th is L ED to bl ink o n an d off whe n th at parti cu la r dr ive i s be ing a c c es se d.
Please refer to Chapter 6 for instructions on replacing failed SAS/SATA drives.
Red: The red LED to indicate a SAS/SATA drive failure. If one of the drives
fail, you should be notifi ed by your system management software. Please refer to
Chapter 6 for instructions on replacing failed SAS/SATA drives.
The following statements are industry standard warnings, provided to warn the user
of situations which have the potential for bodily injury. Should you have questions
or experience difficulty, contact Supermicro's Technical Support department
for assistance. Only certifi ed technicians should attempt to install or confi gure
components.
Read this appendix in its entirety before installing or confi guring components in the
Supermicro chassis.
These warnings may also be found on our web site at http://www.supermicro.com/
about/policies/safety_information.cfm.
Warning Defi nition
Warning!
This warning symbol means danger. You are in a situation that could cause bodily
injury. Before you work on any equipment, be aware of the hazards involved with
electrical circuitry and be familiar with standard practices for preventing accidents.
Warnung
WICHTIGE SICHERHEITSHINWEISE
Dieses Warnsymbol bedeutet Gefahr. Sie befi nden sich in einer Situation, die zu
Verletzungen führen kann. Machen Sie sich vor der Arbeit mit Geräten mit den
Gefahren elektrischer Schaltungen und den üblichen Verfahren zur Vorbeugung
vor Unfällen vertraut. Suchen Sie mit der am Ende jeder Warnung angegebenen
Anweisungsnummer nach der jeweiligen Übersetzung in den übersetzten
Sicherheitshinweisen, die zusammen mit diesem Gerät ausgeliefert wurden.
BEWAHREN SIE DIESE HINWEISE GUT AUF.
INSTRUCCIONES IMPORTANTES DE SEGURIDAD
Este símbolo de aviso indica peligro. Existe riesgo para su integridad física. Antes
de manipular cualquier equipo, considere los riesgos de la corriente eléctrica y
familiarícese con los procedimientos estándar de prevención de accidentes. Al
fi nal de cada advertencia encontrará el número que le ayudará a encontrar el texto
traducido en el apartado de traducciones que acompaña a este dispositivo.
GUARDE ESTAS INSTRUCCIONES.
IMPORTANTES INFORMATIONS DE SÉCURITÉ
Ce symbole d'avertissement indique un danger. Vous vous trouvez dans une
situation pouvant entraîner des blessures ou des dommages corporels. Avant
de travailler sur un équipement, soyez conscient des dangers liés aux circuits
électriques et familiarisez-vous avec les procédures couramment utilisées pour
éviter les accidents. Pour prendre connaissance des traductions des avertissements
fi gurant dans les consignes de sécurité traduites qui accompagnent cet appareil,
référez-vous au numéro de l'instruction situé à la fi n de chaque avertissement.