SUPER
SUPER SERVER 6014L-M4
USER’S MANUAL
Revision 1.0
The information in this User’s Manual has been carefully reviewed and is believed to be accurate.
The vendor assumes no responsibility for any inaccuracies that may be contained in this document,
makes no commitment to update or to keep current the information in this manual, or to notify any
person or organization of the updates.
Please Note: For the most up-to-date version of
this manual, please see our web site at www.supermicro.com.
SUPERMICRO COMPUTER reserves the right to make changes to the product described in this
manual at any time and without notice. This product, including software, if any, and documentation may not, in whole or in part, be copied, photocopied, reproduced, translated or reduced to any
medium or machine without prior written consent.
IN NO EVENT WILL SUPERMICRO COMPUTER BE LIABLE FOR DIRECT, INDIRECT, SPECIAL,
INCIDENTAL, SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE
OR INABILITY TO USE THIS PRODUCT OR DOCUMENTATION, EVEN IF ADVISED OF THE
POSSIBILITY OF SUCH DAMAGES. IN PARTICULAR, THE VENDOR SHALL NOT HAVE
LIABILITY FOR ANY HARDWARE, SOFTWARE, OR DATA STORED OR USED WITH THE
PRODUCT, INCLUDING THE COSTS OF REPAIRING, REPLACING, INTEGRATING, INSTALLING
OR RECOVERING SUCH HARDWARE, SOFTWARE, OR DATA.
Any disputes arising between manufacturer and customer shall be governed by the laws of Santa
Clara County in the State of California, USA. The State of California, County of Santa Clara shall
be the exclusive venue for the resolution of any such disputes. Supermicro's total liability for all
claims will not exceed the price paid for the hardware product.
Manual Revision 1.0
Release Date: February 23, 2006
Unless you request and receive written permission from SUPER MICRO COMPUTER, you may not
copy any part of this document.
Information in this document is subject to change without notice. Other products and companies
referred to herein are trademarks or registered trademarks of their respective companies or mark
holders.
Copyright © 2006 by SUPER MICRO COMPUTER INC.
All rights reserved.
Printed in the United States of America
Preface
About This Manual
This manual is written for professional system integrators and PC technicians. It
provides information for the installation and use of the SuperServer 6014L-M4. In-
stallation and maintenance should be performed by experienced technicians only.
The SuperServer 6014L-M4 is a high-end dual processor rackmount server based
on the SC813MS-300C 1U rackmount server chassis and the Super X6DLP-4G2
serverboard. The X6DLP-4G2 supports Intel
479-pin PGA sockets.
® Xeon ® LV or ULV processors in
Preface
Manual Organization
Chapter 1: Introduction
The fi rst chapter provides a checklist of the main components included with the serv-
er system and describes the main features of the Super X6DLP-4G2 serverboard
and the SC813MS-300C chassis.
Chapter 2: Server Installation
This chapter describes the steps necessary to install the SuperServer 6014L-M4 into
a rack and check out the server confi guration prior to powering up the system. If
your server was ordered without the processor and memory components, this chap-
ter will refer you to the appropriate sections of the manual for their installation.
Chapter 3: System Interface
Refer to this chapter for details on the system interface, which includes the functions
and information provided by the control panel on the chassis as well as other LEDs
located throughout the system.
iii
SUPER SERVER 6014L-M4 User's Manual
Chapter 4: System Safety
You should thoroughly familiarize yourself with this chapter for a general overview
of safety precautions that should be followed when installing and servicing the
SuperServer 6014L-M4.
Chapter 5: Advanced Serverboard Setup
Chapter 5 provides detailed information on the X6DLP-4G2 serverboard, including
the locations and functions of connectors, headers and jumpers. Refer to this chap-
ter when adding or removing processors or main memory and when reconfi guring
the serverboard.
Chapter 6: Advanced Chassis Setup
Refer to Chapter 6 for detailed information on the SC813MS-300C 1U rackmount
server chassis. You should follow the procedures given in this chapter when install-
ing, removing or reconfi guring SCSI or peripheral drives and when replacing system
power supply units and cooling fans.
Chapter 7: BIOS
The BIOS chapter includes an introduction to BIOS and provides detailed informa-
tion on running the CMOS Setup Utility.
Appendix A: BIOS Error Beep Codes
Appendix B: BIOS POST Checkpoint Codes
Appendix C: Software Installation
Appendix D: System Specifi cations
iv
Notes
Preface
v
SUPER SERVER 6014L-M4 User's Manual
Table of Contents
Preface
About This Manual ...................................................................................................... iii
Manual Organization ................................................................................................... iii
Chapter 1: Introduction
1-1 Overview ......................................................................................................... 1-1
1-2 Serverboard Features ..................................................................................... 1-2
1-3 Server Chassis Features ................................................................................ 1-5
1-4 Contacting Supermicro ................................................................................... 1-7
Chapter 2: Server Installation
2-1 Overview ......................................................................................................... 2-1
2-2 Unpacking the System ................................................................................... 2-1
2-3 Preparing for Setup ........................................................................................ 2-1
Choosing a Setup Location .................................................................... 2-2
Rack Precautions ..................................................................................... 2-2
Server Precautions ................................................................................... 2-2
Rack Mounting Considerations ................................................................ 2-3
2-4 Installing the System into a Rack ................................................................... 2-4
Identifying the Sections of the Rack Rails ............................................... 2-4
Installing the Rear Inner Rails ................................................................. 2-4
Installing the Rack Rails .......................................................................... 2-5
Installing the Server into the Rack ........................................................... 2-6
Installing the Server into a Telco Rack .................................................... 2-7
2-5 Checking the Serverboard Setup ................................................................... 2-8
2-6 Checking the Drive Bay Setup ..................................................................... 2-10
Chapter 3: System Interface
3-1 Overview ......................................................................................................... 3-1
3-2 Control Panel Buttons .................................................................................... 3-1
Reset ........................................................................................................ 3-1
Power ....................................................................................................... 3-1
3-3 Control Panel LEDs ........................................................................................ 3-2
Overheat/Fan Fail .................................................................................... 3-2
NIC2 ......................................................................................................... 3-2
NIC1 ......................................................................................................... 3-2
HDD .......................................................................................................... 3-2
Power ....................................................................................................... 3-3
vi
Table of Contents
3-4 SCSI Drive Carrier LEDs ................................................................................ 3-3
Chapter 4: System Safety
4-1 Electrical Safety Precautions .......................................................................... 4-1
4-2 General Safety Precautions ........................................................................... 4-2
4-3 ESD Precautions ............................................................................................ 4-3
4-4 Operating Precautions .................................................................................... 4-4
Chapter 5: Advanced Serverboard Setup
5-1 Handling the Serverboard .............................................................................. 5-1
5-2 Serverboard Installation .................................................................................. 5-2
5-3 Processor and Heatsink Installation ............................................................... 5-3
5-4 Connecting Cables ......................................................................................... 5-6
Connecting Data Cables .......................................................................... 5-6
Connecting Power Cables ....................................................................... 5-6
Connecting the Control Panel .................................................................. 5-7
5-5 I/O Ports ......................................................................................................... 5-7
5-6 Installing the Processor .................................................................................. 5-5
5-7 Installing Memory ........................................................................................... 5-8
5-8 Adding PCI Cards ........................................................................................... 5-9
5-9 Serverboard Details ...................................................................................... 5-10
X6DLP-4G2 Layout ................................................................................ 5-10
X6DLP-4G2 Quick Reference ................................................................ 5-11
5-10 Connector Defi nitions ................................................................................... 5-12
ATX Power Connector ........................................................................... 5-12
Processor Power Connector .................................................................. 5-12
NMI Button ............................................................................................. 5-12
Power LED ............................................................................................. 5-12
HDD LED ............................................................................................... 5-13
NIC1/NIC LEDs ...................................................................................... 5-13
Overheat/Fan Fail LED .......................................................................... 5-13
Power Fail LED ...................................................................................... 5-13
Reset Connector .................................................................................... 5-14
Power Button .......................................................................................... 5-14
JLAN1/2 Ethernet Ports ......................................................................... 5-14
Chassis Intrusion .................................................................................... 5-14
Universal Serial Bus ............................................................................... 5-15
Universal Serial Bus Headers ................................................................ 5-15
Fan Headers .......................................................................................... 5-15
vii
SUPER SERVER 6014L-M4 User's Manual
Speaker/Power LED/Keylock ................................................................. 5-16
Wake-On-Ring ........................................................................................ 5-16
Wake-On-LAN ........................................................................................ 5-16
Power Fault ............................................................................................ 5-17
ATX PS/2 Keyboard and PS/2 Mouse Ports ......................................... 5-17
SMB Power Connector .......................................................................... 5-17
Serial Ports ............................................................................................. 5-17
5-11 Jumper Settings ............................................................................................ 5-18
Explanation of Jumpers ......................................................................... 5-18
CMOS Clear ........................................................................................... 5-18
JLAN1/2 Enable/Disable ........................................................................ 5-18
VGA Enable/Disable ............................................................................... 5-19
SMBus to PCI Slots ............................................................................... 5-19
Power Force On ..................................................................................... 5-19
Watch Dog ............................................................................................. 5-19
Alarm Reset ........................................................................................... 5-20
SCSI Enable/Disable .............................................................................. 5-20
SCSI Termination Enable/Disable .......................................................... 5-20
5-12 Onboard Indicators ....................................................................................... 5-21
JLAN LEDs ............................................................................................. 5-21
System Status LEDs .............................................................................. 5-21
Onboard LED Indicators ........................................................................ 5-21
5-13 Parallel Port, Floppy, IDE, SATA and SCSI Drive Connections ................... 5-22
Parallel Port ............................................................................................ 5-22
Floppy Connector ................................................................................... 5-23
SATA Connectors ................................................................................... 5-23
IDE Connector ........................................................................................ 5-24
SCSI Connector ..................................................................................... 5-25
Chapter 6: Advanced Chassis Setup
6-1 Static-Sensitive Devices ................................................................................. 6-1
6-2 Control Panel .................................................................................................. 6-2
6-3 System Fans ................................................................................................... 6-3
System Fan Failure .................................................................................. 6-3
6-4 Drive Bay Installation/Removal ...................................................................... 6-3
Removing the Front Bezel ....................................................................... 6-3
Accessing the Drive Bays ........................................................................ 6-4
SCSI Drive Installation ............................................................................. 6-4
SCA Backplane ........................................................................................ 6-5
viii
Table of Contents
CD/DVD-ROM Drive Installation .............................................................. 6-6
6-5 Power Supply ................................................................................................. 6-7
Power Supply Failure ............................................................................... 6-7
Replacing the Power Supply .................................................................... 6-7
Chapter 7: BIOS
7-1 Introduction ..................................................................................................... 7-1
7-2 Main Setup ..................................................................................................... 7-2
7-3 Advanced Settings .......................................................................................... 7-3
7-4 Boot Settings ................................................................................................ 7-15
7-5 Security Settings ........................................................................................... 7-18
7-6 Exit Options .................................................................................................. 7-19
Appendices:
Appendix A: BIOS Error Beep Codes ...................................................................... A-1
Appendix B: BIOS POST Checkpoint Codes .......................................................... B-1
Appendix C: Software Installation ........................................................................... C-1
Appendix D: System Specifi cations ........................................................................ D-1
ix
SUPER SERVER 6014L-M4 User's Manual
Notes
x
Chapter 1: Introduction
Chapter 1
Introduction
1-1 Overview
The SuperServer 6014L-M4 is a high-end dual processor, 1U rackmount server
featuring state-of-the-art technology. The 6014L-M4 is comprised of two main
subsystems: the SC813MS-300C 1U rackmount chassis and the X6DLP-4G2
serverboard. Please refer to our web site for information on operating systems that
have been certifi ed for use with the 6014L-M4 (www.supermicro.com).
In addition to the serverboard and chassis, various hardware components may have
been included with the 6014L-M4, as listed below.
Two (2) CPU heatsinks (SNK-P0019)
One (1) slim DVD drive [DVM-PNSC-824(B)]
SCSI Accessories:
Four (4) SCSI hard drive carriers (CSE-PT-39(B))
One (1) SCSI backplane (CSE-SATA-813S)
One (1) SCSI cables (CBL-0043)
One (1) 3.3V 64-bit, 66 MHz PCI-X slot riser card (CSE-RR1U-X)
Three (3) cooling fans (FAN-0061)
Rackmount hardware with screws (CSE-PT52):
Two (2) rack rail assemblies
Six (6) brackets for mounting the rack rails in a rack/telco rack
One (1) CD containing drivers and utilities
SuperServer 6014L-M4 User's Manual
Note: "B" indicates part is also available in black.
1-1
S
UPERS ERVER 6014L-M4 User's Manual
1-2 Serverboard Features
At the heart of the SuperServer lies the X6DLP-4G2, a dual processor serverboard
based on Intel's E7520 chipset and designed to provide maximum performance.
Below are the main features of the X6DLP-4G2.
Processors
The X6DLP-4G2 supports single or dual Intel® Xeon® LV or ULV processors in
479-pin PGA sockets. Please refer to our web site for a complete listing of sup-
ported processors (www.supermicro.com).
Memory
The X6DLP-4G2 has eight (8) 240-pin DIMM sockets that can support up to 16 GB
of registered ECC DDR2-400 SDRAM. The memory bus is a dual-channel confi gu-
ration and memory modules must be installed in pairs (two at a time). All memory
modules used to populate the system should be the same size, type and speed.
SCSI Subsystem
The onboard Adaptec AIC-7902 SCSI controller supports four 80-pin SCA Ultra320
SCSI hard drives. (SCA = Single Connection Attachment.) The SCSI drives are
connected to an SCA backplane that provides power, bus termination and confi gura-
tion settings. The SCSI drives are hot-swap units.
PCI Expansion Slots
The X6DLP-4G2 has two 64-bit, 66 MHz (3.3V) PCI-X slots, two x8 PCI-Express
slots and one 32-bit, 33 MHz (5V) PCI slot. When confi gured as the X6DLP-4G2,
the 64-bit, 133 MHz PCI-X slot is available with the use of a riser card (included
with the system). (Alternatively, the optional CSE-RR1U-EL riser card may be used
to support an add-on card in the x8 PCI-Express slot.)
Ethernet Ports
The X6DLP-4G2 has one Intel 82573V and one Intel 82573L single port Ethernet
controllers to support two Gigabit LAN ports. (Supports 100/1000 BASE-T, RJ45
output.)
1-2
Chapter 1: Introduction
Onboard Controllers/Ports
An onboard IDE controller supports up to four UltraDMA/100 hard drives or ATAPI
devices. Onboard I/O backpanel ports include one COM port, a VGA port, two USB
ports, PS/2 mouse and keyboard ports and two GLAN (NIC) ports.
Other Features
Other onboard features that promote system health include voltage monitors, a
chassis intrusion header, auto-switching voltage regulators, chassis and CPU
overheat sensors, virus protection and BIOS rescue.
1-3
S
UPERS ERVER 6014L-M4 User's Manual
8x PCI-Express (Slot 6)
8x PCI-Express (Slot 3)
SCSI Connector
AIC-
7901
PCI 33 MHz (Slot 1)
LAN
LAN
82573
82573
PCI-X 66 MHz (Slot 6)
PCI-X 66 MHz (Slot 5)
ATI
Rage
CPU1
Group A
Links0-7
Group B
Links0-7
Kybd/
Mouse
667 MT/s
E7520
MCH
6300ESB
LPC
S I/O BIOS
Floppy
CPU2
DDR2-400
DIMM 1A
DIMM 2A
DIMM 3A
DIMM 4A
DIMM 1B
DIMM 2B
DIMM 3B
DIMM 4B
SATA Ports (4)
IDE (ATA133)
USB Ports (4)
IPMI
COM
Ports
Note: This is a general block diagram. Please see Chapter 5 for details.
Figure 1-1 . Intel E7520 Chipset:
System Block Diagram
1-4
Chapter 1: Introduction
1-3 Server Chassis Features
The following is a general outline of the main features of the SC813MS-300C
chassis.
System Power
When confi gured as a SuperServer 6014L-M4, the SC813MS-300C chassis in-
cludes a single 300W power supply.
SCSI Subsystem
The SC813MS-300C chassis was designed to support four SCSI hard drives. These
drives are hot-swappable units.
Note: The operating system you use must have RAID support to enable the hot-
swap capability of the SCSI drives.
Control Panel
The SC813MS-300C's control panel provides important system monitoring and
control information. LEDs indicate power on, network activity, hard disk drive activ-
ity and system overheat conditions. The control panel also includes a main power
button and a system reset button.
Rear I/O Panel
The SC813MS-300C is a 1U rackmount chassis. Its I/O panel provides one PCI
expansion slot, one COM port (another is internal), two USB ports, PS/2 mouse and
keyboard ports, a VGA port and two Gb Ethernet ports. (See Figure 1-2.)
1-5
S
UPERS ERVER 6014L-M4 User's Manual
Figure 1-2. Rear I/O Panel
Cooling System
The SC813MS-300C chassis has an innovative cooling design that features three
4-cm high-performance system cooling fans. Each of these fans plug into a chassis
fan header on the serverboard. An air shroud channels the airfl ow generated by
the fans to effi ciently cool the processor area of the system.
A fan speed control setting in BIOS allows fan speed to be determined by system
temperature [the recommended setting is 3-pin (Server)].
1-6
Chapter 1: Introduction
1-4 Contacting Supermicro
Headquarters
Address: SuperMicro Computer, Inc.
980 Rock Ave.
San Jose, CA 95131 U.S.A.
Tel: +1 (408) 503-8000
Fax: +1 (408) 503-8008
Email: marketing@supermicro.com (General Information)
support@supermicro.com (Technical Support)
Web Site: www.supermicro.com
Europe
Address: SuperMicro Computer B.V.
Het Sterrenbeeld 28, 5215 ML
's-Hertogenbosch, The Netherlands
Tel: +31 (0) 73-6400390
Fax: +31 (0) 73-6416525
Email: sales@supermicro.nl (General Information)
support@supermicro.nl (Technical Support)
rma@supermicro.nl (Customer Support)
Asia-Pacifi c
Address: SuperMicro, Taiwan
4F, No. 232-1, Liancheng Rd.
Chung-Ho 235, Taipei County
Taiwan, R.O.C.
Tel: +886-(2) 8226-3990
Fax: +886-(2) 8226-3991
Web Site: www.supermicro.com.tw
Technical Support:
Email: support@supermicro.com.tw
Tel: 886-2-8228-1366, ext.132 or 139
1-7
S
UPERS ERVER 6014L-M4 User's Manual
Notes
1-8
Chapter 2: Server Installation
Chapter 2
Server Installation
2-1 Overview
This chapter provides a quick setup checklist to get your SuperServer 6014L-M4
up and running. Following the steps in the order given should enable you to have
the system operational within a minimal amount of time. This quick setup assumes
that your 6014L-M4 system has come to you with the processors and memory
preinstalled. If your system is not already fully integrated with a serverboard,
processor(s), system memory etc., please turn to the chapter or section noted in
each step for details on installing specifi c components.
2-2 Unpacking the System
You should inspect the box the SuperServer 6014L-M4 was shipped in and note
if it was damaged in any way. If the server itself shows damage, you should fi le a
damage claim with the carrier who delivered it.
Decide on a suitable location for the rack unit that will hold the SuperServer 6014L-
M4. It should be situated in a clean, dust-free area that is well ventilated. Avoid
areas where heat, electrical noise and electromagnetic fi elds are generated. You
will also need it placed near a grounded power outlet. Read the Rack and Server
Precautions in the next section.
2-3 Preparing for Setup
The box the SuperServer 6014L-M4 was shipped in should include two sets of
rail assemblies, six rail mounting brackets and the mounting screws you will need
to install the system into the rack. Follow the steps in the order given to complete
the installation process in a minimal amount of time. Please read this section in
its entirety before you begin the installation procedure outlined in the sections that
follow.
2-1
S
UPERS ERVER 6014L-M4 User's Manual
Choosing a Setup Location
- Leave enough clearance in front of the rack to enable you to open the front door
completely (~25 inches).
- Leave approximately 30 inches of clearance in the back of the rack to allow for
suffi cient airfl ow and ease in servicing.
- This product is for installation only in a Restricted Access Location (dedicated
equipment rooms, service closets, etc.).
!
Warnings and Precautions!
!
Rack Precautions
- Ensure that the leveling jacks on the bottom of the rack are fully extended to the
fl oor with the full weight of the rack resting on them.
- In a single rack installation, stabilizers should be attached to the rack.
- In multiple rack installations, the racks should be coupled together.
- Always make sure the rack is stable before extending a component from the
rack.
- You should extend only one component at a time - extending two or more simul-
taneously may cause the rack to become unstable.
Server Precautions
- Review the electrical and general safety precautions in Chapter 4.
- Determine the placement of each component in the rack before you install the
rails.
- Install the heaviest server components on the bottom of the rack fi rst, and then
work up.
- Use a regulating uninterruptible power supply (UPS) to protect the server from
power surges, voltage spikes and to keep your system operating in case of a power
failure.
-
Allow the power supply units and hot plug SCSI drives to cool before touching
them.
-
Always keep the rack's front door and all panels and components on the servers
closed when not servicing to maintain proper cooling.
2-2
Chapter 2: Server Installation
Rack Mounting Considerations
Ambient Operating Temperature
If installed in a closed or multi-unit rack assembly, the ambient operating tempera-
ture of the rack environment may be greater than the ambient temperature of the
room. Therefore, consideration should be given to installing the equipment in an
environment compatible with the manufacturer’s maximum rated ambient tempera-
ture (Tmra).
Reduced Airfl ow
Equipment should be mounted into a rack so that the amount of airfl ow required
for safe operation is not compromised.
Mechanical Loading
Equipment should be mounted into a rack so that a hazardous condition does not
arise due to uneven mechanical loading.
Circuit Overloading
Consideration should be given to the connection of the equipment to the power
supply circuitry and the effect that any possible overloading of circuits might have
on overcurrent protection and power supply wiring. Appropriate consideration of
equipment nameplate ratings should be used when addressing this concern.
Reliable Ground
A reliable ground must be maintained at all times. To ensure this, the rack itself
should be grounded. Particular attention should be given to power supply connec-
tions other than the direct connections to the branch circuit (i.e. the use of power
strips, etc.).
2-3
S
UPERS ERVER 6014L-M4 User's Manual
2-4 Installing the System into a Rack
This section provides information on installing the SuperServer 6014L-M4 into a
rack unit with the rack rails provided. If the server has already been mounted into
a rack, you can skip ahead to Sections 2-5 and 2-6. There are a variety of rack
units on the market, which may mean the assembly procedure will differ slightly.
You should also refer to the installation instructions that came with the rack unit
you are using.
Identifying the Sections of the Rack Rails
You may have received rack rail hardware with the SuperServer 6014L-M4. (Two
front inner rails should already be attached to the chassis.) This hardware consists
of two rear inner rails that secure to the chassis, one on each side just behind the
preinstalled front inner rails. Note that these two rails are left/right specifi c.
Installing the Rear Inner Rails
First, locate the right rear inner rail (the rail that will be used on the right side of
the chassis when you face the front of the chassis). Align the two square holes
on the rail against the hooks on the right side of the chassis. Securely attach the
rail to the chassis with M4 fl at head screws. Repeat these steps to install the left
rear inner rail to the left side of the chassis (see Figure 2-1). You will also need to
attach the rail brackets when installing into a telco rack.
Locking Tabs: Both chassis rails have a locking tab, which serves two functions.
The fi rst is to lock the server into place when installed and pushed fully into the
rack, which is its normal position. Secondly, these tabs also lock the server in place
when fully extended from the rack. This prevents the server from coming completely
out of the rack when you pull it out for servicing.
2-4
Chapter 2: Server Installation
Figure 2-1. Installing Rear Inner Chassis Rails
Installing the Rack Rails
Determine where you want to place the SuperServer 6014L-M4 in the rack (see
Rack and Server Precautions in Section 2-3). Position the chassis rail guides at
the desired location in the rack, keeping the sliding rail guide facing the inside of
the rack. Screw the assembly securely to the rack using the brackets provided.
Attach the other assembly to the other side of the rack, making sure that both are
at the exact same height and with the rail guides facing inward.
2-5
S
UPERS ERVER 6014L-M4 User's Manual
Installing the Server into the Rack
You should now have rails attached to both the chassis and the rack unit. The next
step is to install the server into the rack. Do this by lining up the rear of the chas-
sis rails with the front of the rack rails. Slide the chassis rails into the rack rails,
keeping the pressure even on both sides (you may have to depress the locking
tabs when inserting). See Figure 2-2.
When the server has been pushed completely into the rack, you should hear the
locking tabs "click". Finish by inserting and tightening the thumbscrews that hold
the front of the server to the rack.
Figure 2-2. Installing the Server into a Rack
(with optional front bezel shown)
2-6
Chapter 2: Server Installation
Installing the Server into a Telco Rack
If you are installing the SuperServer 6014L-M4 into a Telco type rack, follow the di-
rections given on the previous pages for rack installation. The only difference in the
installation procedure will be the positioning of the rack brackets to the rack. They
should be spaced apart just enough to accommodate the width of the telco rack.
Figure 2-3. Installing the Server into a Telco Rack
(with optional front bezel shown)
2-7
S
UPERS ERVER 6014L-M4 User's Manual
2-5 Checking the Motherboard Setup
After you install the 6014L-M4 in the rack, you will need to open the unit to make sure
the motherboard is properly installed and all the connections have been made.
1. Accessing the inside of the system (Figure 2-4)
First, grasp the two handles on either side and pull the unit straight out until it locks
(you will hear a "click"). Next, depress the two buttons on the top of the chassis to
release the top cover. There is a large rectangular recess in the middle front of the
top cover to help you push the cover away from you until it stops. You can then lift
the top cover from the chassis to gain full access to the inside of the server.
2. Check the CPUs (processors)
You may have one or two processors already installed into the system board. Each
processor should have its own heatsink attached. See Chapter 5 for instructions
on processor installation.
3. Check the system memory
Your 6014L-M4 server system may have come with system memory already in-
stalled. Make sure all DIMMs are fully seated in their slots. For details on adding
system memory, refer to Chapter 5.
4. Installing add-on cards
If desired, you can install an add-on card to the system. See Chapter 5 for details
on installing a PCI add-on card.
5. Check all cable connections and airfl ow
Make sure all power and data cables are properly connected and not blocking the
airfl ow. See Chapter 5 for details on cable connections. Also, check the air seals
for damage. The air seals are located under the chassis fans and beneath the
frame cross section that separates the drive bay area from the motherboard area
of the chassis.
2-8
Chapter 2: Server Installation
Figure 2-4.
Accessing the Inside of the SuperServer 6014L-M4
2-9
S
UPERS ERVER 6014L-M4 User's Manual
2-6 Checking the Drive Bay Setup
Next, you should check to make sure the peripheral drives and the SCSI drives
and SCSI backplane have been properly installed and all essential connections
have been made.
1. Accessing the drive bays
All drives can be accessed from the front of the server. For servicing the CD-ROM
drive, you will need to remove the top chassis cover. The SCSI disk drives can
be installed and removed from the front of the chassis without removing the top
chassis cover.
2. Installing a CD-ROM drive
Refer to Chapter 6 if you need to reinstall a CD-ROM drive to the system.
3. Check the SCSI disk drives
Depending upon your system's confi guration, your system may have one or more
SCSI drives already installed. If you need to install SCSI drives, please refer to
the appropriate section in Chapter 6.
4. Check the airfl o w
Airfl ow is provided by three high-performance 4-cm input fans. The system com-
ponent layout was carefully designed to promote suffi cient airfl ow through the small
1U rackmount space. Also note that all power and data cables have been routed
in such a way that they do not block the airfl ow generated by the fans.
5. Supplying power to the system
The last thing you must do is to provide input power to the system. Plug the power
cord from the power supply unit into a high-quality power strip that offers protec-
tion from electrical noise and power surges. It is recommended that you use an
uninterruptible power supply (UPS). Finish by pressing the power button on the
front of the chassis.
2-10
Chapter 3: System Interface
Chapter 3
System Interface
3-1 Overview
There are several LEDs on the control panel as well as others on the SCSI drive
carriers to keep you constantly informed of the overall status of the system as well
as the activity and health of specifi c components. There are also two buttons on
the chassis control panel. This chapter explains the meanings of all LED indicators
and the appropriate response you may need to take.
3-2 Control Panel Buttons
There are two push-button buttons located on the front of the chassis: a reset but-
ton and a power on/off button.
RESET:
POWER: This is the main power switch, which is used to apply or turn off
the main system power. Turning off system power with this button removes the
main power but keeps standby power supplied to the system.
The reset switch reboots the system.
3-1
S
UPERS ERVER 6014L-M4 User's Manual
3-3 Control Panel LEDs
The control panel located on the front of the chassis has fi ve LEDs. These LEDs
provide you with critical information related to different parts of the system. This
section explains what each LED indicates when illuminated and any corrective ac-
tion you may need to take.
Overheat/Fan Fail: When this LED fl ashes, it indicates a fan failure. When
on continuously it indicates an overheat condition, which may be caused by cables
obstructing the airfl ow in the system or the ambient room temperature being too
warm. Check the routing of the cables and make sure all fans are present and
operating normally. You should also check to make sure that the chassis covers
are installed. Finally, verify that the heatsinks are installed properly (see Chapter
5). This LED will remain fl ashing or on as long as the indicated condition exists.
2
NIC2: Indicates network activity on JLAN2 when fl ashing .
1
NIC1: Indicates network activity on JLAN1 when fl ashing.
HDD: Channel activity for all HDDs. This light indicates CD-ROM and SCSI
drive activity when fl ashing.
3-2