Supermicro SUPERSERVER 6013A-T User Manual

®
SUPER
SUPERSERVER 6013A-T
USER’S MANUAL
Revision 1.1b
The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccuracies that may be contained in this document, makes no commitment to update or to keep current the information in this manual, or to notify any person or organization of the updates.
Please Note: For the most up-to-date version of this manual, please see our web site at www.supermicro.com.
SUPERMICRO COMPUTER reserves the right to make changes to the product described in this manual at any time and without notice. This product, including software, if any, and documentation may not, in whole or in part, be copied, photocopied, reproduced, translated or reduced to any medium or machine without prior written consent.
IN NO EVENT WILL SUPERMICRO COMPUTER BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL, SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO USE THIS PRODUCT OR DOCUMENTATION, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. IN PARTICULAR, THE VENDOR SHALL NOT HAVE LIABILITY FOR ANY HARDWARE, SOFTWARE, OR DATA STORED OR USED WITH THE PRODUCT, INCLUDING THE COSTS OF REPAIRING, REPLACING, INTEGRATING, INSTALLING OR RECOVERING SUCH HARDWARE, SOFTWARE, OR DATA.
Any disputes arising between manufacturer and customer shall be governed by the laws of Santa Clara County in the State of California, USA. The State of California, County of Santa Clara shall be the exclusive venue for the resolution of any such disputes. Supermicro's total liability for all claims will not exceed the price paid for the hardware product.
Unless you request and receive written permission from SUPER MICRO COMPUTER, you may not copy any part of this document.
Information in this document is subject to change without notice. Other products and companies referred to herein are trademarks or registered trademarks of their respective companies or mark holders.
Copyright © 2005 by SUPER MICRO COMPUTER INC. All rights reserved.
Printed in the United States of America
Preface
About This Manual
This manual is written for professional system integrators and PC technicians. It provides information for the installation and use of the SuperServer 6013A-T. Installation and maintainance should be performed by experienced technicians only.
The SuperServer 6013A-T is an affordable dual Xeon processor 1U rackmount server based on the SC811T-350 chassis and the Super X5DPA-TGM+ motherboard. The X5DPA-TGM+ supports dual Intel® XeonTM processors of up to
3.20 GHz with a 1 MB cache.
Manual Organization
Chapter 1: Introduction
The first chapter provides a checklist of the main components included with the server system and describes the main features of the Super X5DPA-TGM+ motherboard and the SC811T-350 chassis.
Chapter 2: Server Installation
This chapter describes the steps necessary to install the SuperServer 6013A-T into a rack and check out the server configuration prior to power­ing up the system. If your server was ordered without the processor and memory components, this chapter will refer you to the appropriate sections of the manual for their installation.
Chapter 3: System Interface
Refer to this chapter for details on the system interface, which includes the functions and information provided by the control panel on the chassis as well as other LEDs located throughout the system.
iii
Preface
SUPERSERVER 6013A-T User's Manual
iv
Chapter 4: System Safety
You should thoroughly familiarize yourself with this chapter for a general overview of safety precautions that should be followed when installing and servicing the SuperServer 6013A-T.
Chapter 5: Advanced Motherboard Setup
Chapter 5 provides detailed information on the X5DPA-TGM+ motherboard, in­cluding the locations and functions of connectors, headers and jumpers. Refer to this chapter when adding or removing processors or main memory and when reconfiguring the motherboard.
Chapter 6: Advanced Chassis Setup
Refer to Chapter 6 for detailed information on the SC811T-350 1U rackmount server chassis. You should follow the procedures given in this chapter when installing, removing or reconfiguring Serial ATA or peripheral drives and when replacing system power supply units and cooling fans.
Chapter 7: AMIBIOS
The BIOS chapter includes an introduction to BIOS and provides detailed information on running the CMOS Setup Utility.
Appendix A: BIOS Error Beep Codes
Appendix B: BIOS POST Checkpoint Codes
Appendix C: Software Installation
Appendix D: System Specifications
v
Preface
Notes
vi
Table of Contents
Preface
About This Manual ...................................................................................................... iii
Manual Organization ................................................................................................... iii
Chapter 1: Introduction
1-1 Overview ......................................................................................................... 1-1
1-2 Motherboard Features ................................................................................... 1-2
1-3 Server Chassis Features.............................................................................. 1-5
1-4 Contacting Supermicro .................................................................................. 1-7
Chapter 2: Server Installation
2-1 Overview ......................................................................................................... 2-1
2-2 Unpacking the SuperServer 6013A-T ........................................................ 2-1
2-3 Preparing for Setup ....................................................................................... 2-1
Choosing a Setup Location .................................................................... 2-2
Rack Precautions ..................................................................................... 2-2
Server Precautions.................................................................................. 2-2
Rack Mounting Considerations .............................................................. 2-3
2-4 Installing the SuperServer 6013A-T into a Rack ...................................... 2-4
Identifying the Sections of the Rack Rails .......................................... 2-4
Installing the Chassis Rails ..................................................................... 2-5
Installing the Rack Rails .......................................................................... 2-5
Installing the Server into the Rack ........................................................ 2-6
Installing the Server into a Telco Rack ................................................ 2-7
2- 5 Checking the Motherboard Setup ................................................................ 2-9
2-6 Checking the Drive Bay Setup ................................................................... 2-11
Chapter 3: System Interface
3-1 Overview ......................................................................................................... 3-1
3- 2 Control Panel Buttons .................................................................................... 3-1
Reset.......................................................................................................... 3-1
Power ........................................................................................................ 3-1
3-3 Control Panel LEDs ........................................................................................ 3-2
Overheat ................................................................................................... 3-2
NIC2 ............................................................................................................ 3-2
NIC1 ............................................................................................................ 3-2
HDD ............................................................................................................ 3-2
Power ........................................................................................................ 3-3
SUPERSERVER 6013A-T User's Manual
3- 4 Serial ATA Drive Carrier LED ...................................................................... 3-3
Chapter 4: System Safety
4-1 Electrical Safety Precautions ........................................................................ 4-1
4-2 General Safety Precautions .......................................................................... 4-2
4- 3 ESD Precautions.............................................................................................. 4-3
4-4 Operating Precautions .................................................................................... 4-4
Chapter 5: Advanced Motherboard Setup
5- 1 Handling the X5DPA-TGM+ Motherboard........................................................5-1
5- 2 Motherboard Installation....................................................................................5-2
5- 3 Connecting Cables ............................................................................................5-3
Connecting Data Cables ............................................................................5-3
Connecting Power Cables ..........................................................................5-3
Connecting the Control Panel ...................................................................5-3
5-4 I/O Ports .............................................................................................................5-4
5-5 Processor and Heatsink Installation ...............................................................5-5
5- 6 Installing Memory ..............................................................................................5-9
5- 7 Adding PCI Cards ............................................................................................ 5-10
5- 8 Motherboard Details ........................................................................................ 5-11
X5DPA-TGM+ Layout................................................................................5-11
X5DPA-TGM+ Quick Reference...............................................................5-12
5- 9 Connector Definitions ......................................................................................5-13
ATX Power Connection ........................................................................... 5-13
PWR_SEC Connection .............................................................................5-13
Power LED................................................................................................. 5-13
NMI Button.................................................................................................5-13
HDD LED ...................................................................................................5-14
NIC1 LED ...................................................................................................5-14
NIC2 LED ...................................................................................................5-14
Overheat LED (OH) ................................................................................. 5-14
Power Fail LED .........................................................................................5-14
Reset Button .............................................................................................5-15
Power Button.............................................................................................5-15
Chassis Intrusion ......................................................................................5-15
Universal Serial Bus (USB0/1) ................................................................ 5-15
Front Side USB......................................................................................... 5-16
Serial Ports ............................................................................................. 5-16
Ethernet Ports ......................................................................................... 5-16
vii
Table of Contents
viii
Fan Headers ............................................................................................5-17
Power LED/Speaker ............................................................................... 5-17
ATX PS/2 Keyboard and PS/2 Mouse Ports ...................................... 5-17
SMBus Header ........................................................................................ 5-18
Wake-On-Ring ......................................................................................... 5-18
Keylock .................................................................................................... 5-18
5-10 Jumper Settings............................................................................................. 5-19
Explanation of Jumpers ......................................................................... 5-19
CMOS Clear.............................................................................................. 5-19
Front Side Bus Speed ........................................................................... 5-19
GLAN/LAN Enable/Disable..................................................................... 5-20
VGA Enable/Disable ............................................................................... 5-20
Watch Dog Enable/Disable .................................................................... 5-20
5-11 Onboard Indicators ....................................................................................... 5-20
GLAN/LAN LEDs ..................................................................................... 5-20
5-12 Parallel Port, Floppy and Hard Drive Connections .................................. 5-21
Parallel Port .............................................................................................. 5-21
Floppy Connector ................................................................................... 5-22
IDE Connectors ...................................................................................... 5-22
Chapter 6: Advanced Chassis Setup
6-1 Static-Sensitive Devices ................................................................................ 6-1
6-2 Control Panel .................................................................................................... 6-2
6-3 System Fans .................................................................................................... 6-3
System Fan Failure .................................................................................. 6-3
Replacing System Cooling Fans ............................................................ 6-3
6- 4 Drive Bay Installation/Removal ...................................................................... 6-4
Accessing the Drive Bays ..................................................................... 6-4
Serial ATA Drive Installation.................................................................. 6-4
CD-ROM and Floppy Drive Installation ................................................. 6-6
6-5 Power Supply .................................................................................................. 6-7
Power Supply Failure ............................................................................. 6-7
Replacing the Power Supply ................................................................. 6-7
Chapter 7: AMIBIOS
7- 1 Introduction....................................................................................................... 7-1
7- 2 Main Setup........................................................................................................ 7-2
7-3 Advanced BIOS Setup .................................................................................... 7-5
7-4 Boot Settings .................................................................................................. 7-19
7-5 Security Settings ........................................................................................... 7-21
SUPERSERVER 6013A-T User's Manual
Table of Contents
ix
7- 6 Exit Options .................................................................................................... 7-22
Appendices:
Appendix A: BIOS Error Beep Codes .................................................................. A-1
Appendix B: BIOS POST Checkpoint Codes .........................................................B-1
Appendix C: Software Installation .........................................................................C-1
Appendix D: System Specifications ...................................................................... D-1
x
Notes
SUPERSERVER 6013A-T User's Manual
Chapter 1
Introduction
1-1 Overview
The Supermicro SuperServer 6013A-T is an economical dual Xeon processor, 1U rackmount server with state-of-the-art features. The 6013A-T is comprised of two main subsystems: the SC811T-350 chassis and the X5DPA-TGM+ motherboard. Please refer to our web site for information on operating systems that have been certified for use with the 6013A-T (www.supermicro.com).
In addition to the motherboard and chassis, various hardware components may have been included with your SuperServer 6013A-T, as listed below.
z Two (2) 1U CPU heatsinks (SNK-039)
z Four (4) heatsink retention clips (for either 604 or 603-pin CPUs)
z Two (2) CPU mounting plates and retention modules (SKT-120)
z One (1) 3.5" floppy drive
z One (1) slim CD-ROM drive
z Serial ATA (SATA) Accessories:
One (1) SATA backplane (CSE-SATA-810)
Two (2) SATA cables (CBL-0058)
One (1) SATA LED cable (CBL-0056)
Two (2) SATA drive carriers (CSE-PT10)
z One (1) 5V 32-bit, 33 MHz PCI slot riser card (CSE-RR32-1U)
z Rackmount hardware (with screws):
Two (2) rack rail assemblies
Six (6) brackets for mounting the rack rails in a rack/telco rack
z One (1) CD containing drivers and utilities
Chapter 1: Introduction
1-1
1-2
SUPERSERVER 6013A-T User's Manual
1-2 Motherboard Features
At the heart of the SuperServer 6013A-T lies the X5DPA-TGM+, a dual processor motherboard designed to provide maximum performance. Below are the main features of the X5DPA-TGM+. See Figure 1-1 for a system block diagram of the chipset.
Chipset Overview
Intel’s E7501 chipset is made up of two main components:
The Memory Controller Hub (MCH)
The I/O Controller Hub (ICH5R)
Memory Controller Hub (MCH)
The MCH has four hub interfaces, one to communicate with the ICH5R and three for high-speed I/O communications. The MCH employs a 144-bit wide memory bus for a DDR-266 memory interface, which provides a total bandwidth of 3.2 GB/ s. The ICH5R interface is a 266 MB/sec point-to-point connection using an 8­bit wide, 66 MHz base clock at a 4x data transfer rate. The P64H2 interface is a 1 GB/s point-to-point connection using a 16-bit wide, 66 MHz base clock at a 8x data transfer rate.
I/O Controller Hub (ICH5R)
The I/O Controller Hub (Intel's ICH5R) provides the I/O subsystem with access to the rest of the system. It supports 2-channel Ultra ATA/100 Bus Master IDE Controller, two Serial ATA (SATA) Host Controllers, SMBus 2.0 Controller, LPC/ Flash BIOS Interface, PCI 2.3 Interface, and Integrated System Management Controller.
Processors
The X5DPA-TGM+ supports dual Intel® XeonTM processors of up to 3.20 GHz with a 1 MB cache. Please refer to the support section of our web site for a complete listing of supported processors: (http://www.supermicro.com/ TechSupport.htm).
Chapter 1: Introduction
1-3
Memory
The X5DPA-TGM+ has four (4) 184-pin DIMM sockets that can support up to 8 GB of registered ECC DDR-266/200 SDRAM modules. Low-profile memory modules are required for use in the 1U form factor of the 6013A-T. Module sizes of 128 MB, 256 MB, 512 MB and 2 GB may be used to populate the DIMM slots. (The X5DPA-TGM+ was designed to support 2 GB DIMM modules in each memory slot, but it has only been validated with 1 GB memory modules.)
Serial ATA
The ICH5R hub supports a two-port Serial ATA subsystem, which is RAID 0 and RAID 1 supported. The Serial ATA drives are hot-swappable units. Note: The operating system you use must have RAID support to enable the hot­swap capability and RAID function of the Serial ATA drives.
PCI Expansion Slots
The X5DPA-TGM+ has five 32-bit, 33 MHz PCI slots, one of which is available in the 6013A-T 1U configuration. One riser card is included with the system for use with a 32-bit PCI card.
Ethernet Ports
The X5DPA-TGM+ features Intel's 82541 and 82550 Ethernet controllers, which support one Gb LAN port and one 10/100 Mb LAN port, respectively.
Onboard Controllers/Ports
An onboard IDE controller supports one floppy drive and up to four* Ultra ATA 100 hard drives or ATAPI devices. Onboard I/O backpanel ports include one COM port, a VGA port, two USB ports, PS/2 mouse and keyboard ports, a Gb LAN and a Mb LAN port. (*Only two IDE drives can be housed in the chassis.)
Other Features
Other onboard features that promote system health include eight voltage moni­tors, a chassis intrusion header, auto-switching voltage regulators, chassis and CPU overheat sensors, virus protection and BIOS rescue.
1-4
SUPERSERVER 6013A-T User's Manual
MCH
533/400 M H z System Bus
2 6 6 M H z M e m o ry B u s
ATA 100
P o rts
Processor 1 P rocessor2
2-C hannel
DDR SDRAM
IC H 5 R
U S B P o rts
GLAN
LAN
ATI Rage
32-bit P C I # 1
33 M H z P C I B u s
32-bit P C I # 3
32-bit P C I # 2
32-bit P C I # 4
32-bit P C I # 5
LPC I/O
C O M P o rts
H/W
M onito r
Floppy
Kybd/ M ouse
SATA
Figure 1-1. Intel E7501 Chipset:
System Block Diagram
Note: This is a general block diagram. Please see Chapter 5 for details.
Chapter 1: Introduction
1-5
1-3 Server Chassis Features
The SuperServer 6013A-T is a 1U rackmount server platform designed with some of today's most state-of-the-art features. The following is a general outline of the main features of the SC811T-350 chassis.
System Power
When configured as a SuperServer 6013A-T, the SC811T-350 chassis includes a single 350W power supply.
Serial ATA Subsystem
For the 6013A-T, the SC811T-350 chassis was designed to support two Serial ATA hard drives. The Serial ATA drives are hot-swappable units. (ATA/100 IDE drives are also supported.) Note: The operating system you use must have RAID support to enable the hot-swap capability of the Serial ATA drives.
Control Panel
The control panel on the SC811T-350 provides important system monitoring and control information. LEDs indicate power on, network activity, hard disk drive activity and system overheat conditions. The control panel also includes a main power button and a system reset button.
Rear I/O Panel
The SC811T-350 is a 1U rackmount chassis. Its I/O panel provides one motherboard expansion slot, one COM port (another is internal), two USB ports, PS/2 mouse and keyboard ports, a graphics port and two Ethernet ports (see Figure 1-2).
1-6
SUPERSERVER 6013A-T User's Manual
Cooling System
The SC811T-350 chassis has an innovative cooling design that includes two 10­cm blower fans for system cooling located in the midsection of the chassis. The blower fans plug into chassis fan headers on the motherboard and operate at full rpm continuously. If either break down, the ambient air temperature inside the chassis will rise and activate an overheat LED.
Figure 1-2. Rear I/O Panel
Chapter 1: Introduction
1-7
1-4 Contacting Supermicro
Headquarters
Address: SuperMicro Computer, Inc.
980 Rock Ave.
San Jose, CA 95131 U.S.A. Tel: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: marketing@supermicro.com (General Information)
support@supermicro.com (Technical Support) Web Site: www.supermicro.com
Europe
Address: SuperMicro Computer B.V.
Het Sterrenbeeld 28, 5215 ML
's-Hertogenbosch, The Netherlands Tel: +31 (0) 73-6400390 Fax: +31 (0) 73-6416525 Email: sales@supermicro.nl (General Information)
support@supermicro.nl (Technical Support)
rma@supermicro.nl (Customer Support)
Asia-Pacific
Address: SuperMicro, Taiwan
4F, No. 232-1, Liancheng Rd.
Chung-Ho 235, Taipei County
Taiwan, R.O.C. Tel: +886-(2) 8226-3990 Fax: +886-(2) 8226-3991 Web Site: www.supermicro.com.tw Technical Support: Email: support@supermicro.com.tw Tel: 886-2-8228-1366, ext.132 or 139
1-8
SUPERSERVER 6013A-T User's Manual
Notes
Chapter 2: Server Installation
2-1
Chapter 2
Server Installation
2-1 Overview
This chapter provides a quick setup checklist to get your SuperServer 6013A-T up and running. Following the steps in the order given should enable you to have the system operational within a minimal amount of time. This quick setup assumes that your 6013A-T system has come to you with the processor and memory preinstalled. If your system is not already fully integrated with a motherboard, processor, system memory etc., please turn to the chapter or section noted in each step for details on installing specific components.
2-2 Unpacking the SuperServer 6013A-T
You should inspect the box the SuperServer 6013A-T was shipped in and note if it was damaged in any way. If the server itself shows damage, you should file a damage claim with the carrier who delivered it.
Decide on a suitable location for the rack unit that will hold the SuperServer 6013A-T. It should be situated in a clean, dust-free area that is well venti­lated. Avoid areas where heat, electrical noise and electromagnetic fields are generated. You will also need it placed near a grounded power outlet. Read the Rack and Server Precautions in the next section.
2-3 Preparing for Setup
The box the SuperServer 6013A-T was shipped in should include two sets of rail assemblies, two rail mounting brackets and the mounting screws you will need to install the system into the rack. Follow the steps in the order given to complete the installation process in a minimal amount of time. Please read this section in its entirety before you begin the installation procedure outlined in the sections that follow.
2-2
SUPERSERVER 6013A-T User's Manual
Choosing a Setup Location
- Leave enough clearance in front of the rack to enable you to open
the front door completely (~25 inches).
- Leave approximately 30 inches of clearance in the back of the rack
to allow for sufficient airflow and ease in servicing.
- This product is for installation only in a Restricted Access Location (dedicated equipment rooms, service closets, etc.).
Rack Precautions
- Ensure that the leveling jacks on the bottom of the rack are fully
extended to the floor with the full weight of the rack resting on them.
- In a single rack installation, stabilizers should be attached to the rack.
- In multiple rack installations, the racks should be coupled together.
- Always make sure the rack is stable before extending a component
from the rack.
- You should extend only one component at a time - extending two or
more simultaneously may cause the rack to become unstable.
Server Precautions
- Review the electrical and general safety precautions in Chapter 4.
- Determine the placement of each component in the rack before you
install the rails.
- Install the heaviest server components on the bottom of the rack
first, and then work up.
- Use a regulating uninterruptible power supply (UPS) to protect the server from power surges, voltage spikes and to keep your system operating in case of a power failure.
- Allow the power supply units and hot plug Serial ATA drives to
cool before touching them.
- Always keep the rack's front door and all panels and components on
the servers closed when not servicing to maintain proper cooling.
!
!
Warnings and Precautions!
Chapter 2: Server Installation
2-3
Rack Mounting Considerations
Ambient Operating Temperature
If installed in a closed or multi-unit rack assembly, the ambient operating temperature of the rack environment may be greater than the ambient temperature of the room. Therefore, consideration should be given to installing the equipment in an environment compatible with the manufacturer’s maximum rated ambient temperature (Tmra).
Reduced Airflow
Equipment should be mounted into a rack so that the amount of airflow required for safe operation is not compromised.
Mechanical Loading
Equipment should be mounted into a rack so that a hazardous condition does not arise due to uneven mechanical loading.
Circuit Overloading
Consideration should be given to the connection of the equipment to the power supply circuitry and the effect that any possible overloading of circuits might have on overcurrent protection and power supply wiring. Appropriate consid­eration of equipment nameplate ratings should be used when addressing this concern.
Reliable Ground
A reliable ground must be maintained at all times. To ensure this, the rack itself should be grounded. Particular attention should be given to power supply connections other than the direct connections to the branch circuit (i.e. the use of power strips, etc.).
2-4
SUPERSERVER 6013A-T User's Manual
2-4 Installing the 6013A-T into a Rack
This section provides information on installing the SuperServer 6013A-T into a rack unit. If the system has already been mounted into a rack, you can skip ahead to Sections 2-5 and 2-6. There are a variety of rack units on the market, which may mean the assembly procedure will differ slightly. The following is a guideline for installing the unit into a rack with the rack rails provided with the system. You should also refer to the installation instruc­tions that came with the rack unit you are using.
Identifying the Sections of the Rack Rails
You should have received two rack rail assemblies with the SuperServer 6013A-T. Each of these assemblies consist of two sections: an inner fixed chassis rail that secures to the unit (A) and an outer fixed rack rail that secures directly to the rack itself (B). A sliding rail guide sandwiched between the two should remain attached to the fixed rack rail (see Figure 2-1). The A and B rails must be detached from each other to install.
To remove the fixed chassis rail (A), pull it out as far as possible - you should hear a "click" sound as a locking tab emerges from inside the rail assembly and locks the inner rail. Then depress the locking tab to pull the inner rail completely out. Do this for both the left and right side rack rail assemblies.
Figure 2-1. Identifying the Sections of the Rack Rails
Mounting Holes
A
Locking Tab
B
Chapter 2: Server Installation
2-5
Installing the Chassis Rails
Position the fixed chassis rail sections you just removed along the side of the chassis making sure the five screw holes line up. Note that these two rails are left/right specific. Screw the rail securely to the side of the chassis (see Figure 2-2). Repeat this procedure for the other rail on the other side of the chassis. You will also need to attach the rail brackets when installing into a telco rack.
Locking Tabs: As you have seen, both chassis rails have a locking tab, which serves two functions. The first is to lock the server into place when installed and pushed fully into the rack, which is its normal position. Secondly, these tabs also lock the server in place when fully extended from the rack. This prevents the server from coming completely out of the rack when you pull it out for servicing.
Figure 2-2. Installing Chassis Rails
Installing the Rack Rails
Determine where you want to place the SuperServer 6013A-T in the rack (see Rack and Server Precautions in Section 2-3). Position the fixed rack rail/sliding rail guide assemblies at the desired location in the rack, keeping the sliding rail guide facing the inside of the rack. Screw the assembly
2-6
SUPERSERVER 6013A-T User's Manual
Figure 2-3a. Installing the Server into a Rack
Installing the Server into the Rack
You should now have rails attached to both the chassis and the rack unit. The next step is to install the server into the rack. Do this by lining up the rear of the chassis rails with the front of the rack rails. Slide the chassis rails into the rack rails, keeping the pressure even on both sides (you may have to depress the locking tabs when inserting). See Figure 2-3a and 2-3b.
When the server has been pushed completely into the rack, you should hear the locking tabs "click". Finish by inserting and tightening the thumbscrews that hold the front of the server to the rack.
securely to the rack using the brackets provided. Attach the other assem­bly to the other side of the rack, making sure that both are at the exact same height and with the rail guides facing inward.
Chapter 2: Server Installation
2-7
Installing the Server into a Telco Rack
If you are installing the SuperServer 6013A-T into a Telco type rack, follow the directions given on the previous pages for rack installation. The only difference in the installation procedure will be the positioning of the rack brackets to the rack. They should be spaced apart just enough to accomodate the width of the telco rack.
Figure 2-3b. Installing the Server into a Rack
2-8
SUPERSERVER 6013A-T User's Manual
Figure 2-4. Installing the Server into a Telco Rack
Chapter 2: Server Installation
2-9
2-5 Checking the Motherboard Setup
After you install the 6013A-T in the rack, you will need to open the unit to make sure the motherboard is properly installed and all the connections have been made.
1. Accessing the inside of the 6013A-T (Figure 2-5)
First, release the retention screws that secure the unit to the rack. Grasp the two handles on either side and pull the unit straight out until it locks (you will hear a "click"). Next, depress the two buttons on the top of the chassis to release the top cover. There is a large rectangular recess in the middle front of the top cover to help you push the cover away from you until it stops. You can then lift the top cover from the chassis to gain full access to the inside of the server.
2. Check the CPUs (processors)
You may have one or two processors already installed in the system board. Each processor should have its own heatsink attached. See Chapter 5 for instructions on processor installation.
3. Check the system memory
Your 6013A-T server system may have come with system memory al­ready installed. Make sure all DIMMs are fully seated in their slots. For details on adding system memory, refer to Chapter 5.
4. Installing add-on cards
If desired, you can install an add-on card to the system. See Chapter 5 for details on installing a PCI add-on card.
5. Check all cable connections and airflow
Make sure all power and data cables are properly connected and not blocking the airflow. See Chapter 5 for details on cable connections. Also, check the air seals for damage. The air seals are located under the blower fan and beneath the frame cross section that separates the drive bay area from the motherboard area of the chassis.
Note: Make sure that the air seals are properly installed.
2-10
SUPERSERVER 6013A-T User's Manual
Figure 2-5.
Accessing the Inside of the SuperServer 6013A-T
(with drives removed)
Chapter 2: Server Installation
2-11
2-6 Checking the Drive Bay Setup
Next, you should check to make sure the peripheral drives and the Serial ATA drives and Serial ATA backplane have been properly installed and all essential connections have been made.
1. Accessing the drive bays
All drives can be accessed from the front of the server. For servicing the CD-ROM and floppy drives, you will need to remove the top chassis cover. The Serial ATA disk drives can be installed and removed from the front of the chassis without removing the top chassis cover.
2. Installing a CD-ROM and floppy disk drives
Refer to Chapter 6 if you need to reinstall a CD-ROM and/or floppy disk drive to the system.
3. Check the Serial ATA disk drives
Depending upon your system's configuration, your system may have one or two Serial ATA drives already installed. If you need to install Serial ATA drives, please refer to the appropriate section in Chapter 6.
4. Check the airflow
Airflow is provided by two 10-cm input fans. The system component layout was carefully designed to promote sufficient airflow through the small 1U rackmount space. Also note that all power and data cables have been routed in such a way that they do not block the airflow generated by the fans.
5. Supplying power to the system
The last thing you must do is to provide input power to the system. Plug the power cord from the power supply unit into a high-quality power strip that offers protection from electrical noise and power surges. It is recommended that you use an uninterruptible power supply (UPS).
2-12
SUPERSERVER 6013A-T User's Manual
Notes
Loading...
+ 96 hidden pages