SuperLube 11362 User Manual

Safety Data Sheet
according to (EU) 2015 / 830 and OSHA GHS
Revision: March 7, 2016
1 Identification
·
Product identifier
·
·
Article number:
·
Recommended use and restriction on use
·
Recommended use:
Penetrating oil Lubricant
·
Restrictions on use:
·
Details of the supplier of the Safety Data Sheet
·
Manufacturer/Supplier:
Synco Chemical Corporation 24 DaVinci Dr., P.O. Box 405 Bohemia, NY 11716 Telephone: 631-567-5300
Email: info@super-lube.com
·
Emergency telephone number:
CHEMTREC 1-800-424-9300 (US/Canada) +01 703-527-3887 (International)
No other identifiers
See Sections 8 and 10 for further information.
Page 1 of 14
2 Hazard(s) identification
·
Classification of the substance or mixture
GHS02 GHS04 Flame, Gas cylinder
Flam. Aerosol 1 H222 Extremely flammable aerosol.
GHS04 Gas cylinder
Press. Gas H280 Contains gas under pressure; may explode if heated.
GHS08 Health hazard
Asp. Tox. 1 H304 May be fatal if swallowed and enters airways.
GHS07
Skin Irrit. 2 H315 Causes skin irritation. STOT SE 3 H336 May cause drowsiness or dizziness.
·
Additional information:
There are no other hazards not otherwise classified that have been identified. 0 percent of the mixture consists of ingredient(s) of unknown toxicity.
(Contd. on page 2)
40.1.3
Page 2 of 14
Safety Data Sheet
according to (EU) 2015 / 830 and OSHA GHS
Revision: March 7, 2016
Trade name: Super Lube® Multi-Purpose Synthetic Lubricant with Syncolon® (PTFE) (aerosol)
(Contd. of page 1)
·
Label elements
·
GHS label elements
The product is classified and labeled according to the Globally Harmonized System (GHS).
·
Hazard pictograms
GHS02 GHS04 GHS07 GHS08
·
Signal word
·
Hazard-determining components of labeling:
Distillates (petroleum), hydrotreated light heptane
·
Hazard statements
H222 Extremely flammable aerosol. H280 Contains gas under pressure; may explode if heated. H315 Causes skin irritation. H336 May cause drowsiness or dizziness. H304 May be fatal if swallowed and enters airways.
·
Precautionary statements
P210 Keep away from heat, sparks, open flames, and hot surfaces. - No smoking. P251 Pressurized container: Do not pierce or burn, even after use. P211 Do not spray on an open flame or other ignition source. P261 Avoid breathing mist/vapors/spray. P280 Wear protective gloves and eye protection. P264 Wash thoroughly after handling. P271 Use only outdoors or in a well-ventilated area. P301+P310 If swallowed: Immediately call a poison center/doctor. P304+P340 IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for
P332+P313 If skin irritation occurs: Get medical advice/attention. P302+P352 If on skin: Wash with plenty of water. P362+P364 Take off contaminated clothing and wash it before reuse. P410+P412 Protect from sunlight. Do not expose to temperatures exceeding 122 °F (50 °C). P403 Store in a well-ventilated place. P501 Dispose of contents/container in accordance with local/regional/national/international
·
Hazard description:
·
WHMIS-symbols:
B5 - Flammable aerosol D2B - Toxic material causing other toxic effects
Danger
breathing.
regulations.
(Contd. on page 3)
40.1.3
Page 3 of 14
Safety Data Sheet
according to (EU) 2015 / 830 and OSHA GHS
Revision: March 7, 2016
Trade name: Super Lube® Multi-Purpose Synthetic Lubricant with Syncolon® (PTFE) (aerosol)
(Contd. of page 2)
·
Classification system:
·
NFPA ratings (scale 0 - 4)
Health = 1
133
·
HMIS-ratings (scale 0 - 4)
Fire = 3 Reactivity = 3
HEALTH
FIRE
REACTIVITY
·
Other hazards
·
Results of PBT and vPvB assessment
·
PBT:
·
vPvB:
1
Health = 1
3
Fire = 3
3
Reactivity = 3
Not applicable.
Not applicable.
3 Composition/information on ingredients
·
Chemical characterization: Mixtures
·
Description:
·
Dangerous components:
64742-47-8 Distillates (petroleum), hydrotreated light
142-82-5 heptane
124-38-9 carbon dioxide
8042-47-5 White Mineral Oil
Mixture of the substances listed below with nonhazardous additions.
Asp. Tox. 1, H304
Flam. Liq. 2, H225 Asp. Tox. 1, H304
Skin Irrit. 2, H315; STOT SE 3, H336
Press. Gas, H280
Asp. Tox. 1, H304
25-50%
10-25%
2.5-10%
2.5-10%
·
Ad
ditional information:
For the listed ingredients, the identity and exact percentages are being withheld as a trade secret.
4 First-aid measures
·
Description of first aid measures
·
General information:
Immediately remove any clothing soiled by the product. Take affected persons out into the fresh air.
·
After inhalation:
Supply fresh air; consult doctor in case of complaints. Provide oxygen treatment if affected person has difficulty breathing.
40.1.3
(Contd. on page 4)
Page 4 of 14
Safety Data Sheet
according to (EU) 2015 / 830 and OSHA GHS
Revision: March 7, 2016
Trade name: Super Lube® Multi-Purpose Synthetic Lubricant with Syncolon® (PTFE) (aerosol)
(Contd. of page 3)
·
After skin contact:
Immediately wash with water and soap and rinse thoroughly. If skin irritation continues, consult a doctor.
·
After eye contact:
Remove contact lenses if worn. Rinse opened eye for several minutes under running water. If symptoms persist, consult a doctor.
·
After swallowing:
Unlikely route of exposure. Rinse out mouth and then drink plenty of water. Do not induce vomiting; immediately call for medical help. A person vomiting while lying on their back should be turned onto their side.
·
Information for doctor:
·
Most important symptoms and effects, both acute and delayed
Irritant to skin and mucous membranes. Frostbite Irritating to eyes and skin. Coughing Dizziness Breathing difficulty Nausea
·
Danger
Danger of pulmonary edema. Danger of pneumonia. Danger of impaired breathing.
·
Indication of any immediate medical attention and special treatment needed
If swallowed, gastric irrigation with added, activated carbon. If swallowed or in case of vomiting, danger of entering the lungs. Medical supervision for at least 48 hours. If necessary oxygen respiration treatment. Later observation for pneumonia and pulmonary edema. Treat frost-bitten areas appropriately.
5 Fire-fighting measures
·
Extinguishing media
·
Suitable extinguishing agents:
CO2, extinguishing powder or water spray. Fight larger fires with water spray or alcohol resistant foam.
·
For safety reasons unsuitable extinguishing agents:
·
Special hazards arising from the substance or mixture
Formation of toxic gases is possible during heating or in case of fire. Danger of receptacles bursting because of high vapor pressure if heated.
·
Advice for firefighters
·
Protective equipment:
Wear self-contained respiratory protective device. Wear fully protective suit.
·
Additional information
Eliminate all ignition sources if safe to do so. Leaking gas fire: Do not extinguish, unless leak can be stopped safely.
40.1.3
Water stream.
(Contd. on page 5)
Page 5 of 14
Safety Data Sheet
according to (EU) 2015 / 830 and OSHA GHS
Revision: March 7, 2016
Trade name: Super Lube® Multi-Purpose Synthetic Lubricant with Syncolon® (PTFE) (aerosol)
(Contd. of page 4)
Cool endangered receptacles with water fog.
6 Accidental release measures
·
Personal precautions, protective equipment and emergency procedures
Use respiratory protective device against the effects of fumes/dust/aerosol. Particular danger of slipping on leaked/spilled product. Wear protective equipment. Keep unprotected persons away. Ensure adequate ventilation. Keep away from ignition sources. Protect from heat.
·
Environmental precautions:
Do not allow to enter sewers/ surface or ground water. Inform respective authorities in case of seepage into water course or sewage system.
·
Methods and material for containment and cleaning up:
Absorb with non-combustible liquid-binding material (sand, diatomite, acid binders, universal binders). Pick up mechanically. Dispose contaminated material as waste according to item 13. Do not flush with water or aqueous cleansing agents Send for recovery or disposal in suitable receptacles.
·
Reference to other sections
See Section 7 for information on safe handling. See Section 8 for information on personal protection equipment. See Section 13 for disposal information.
7 Handling and storage
·
Handling:
·
Precautions for safe handling
Use only in well ventilated areas. Keep away from heat and direct sunlight. Avoid splashes or spray in enclosed areas.
·
Information about protection against explosions and fires:
Protect against electrostatic charges. Emergency cooling must be available in case of nearby fire. Keep ignition sources away - Do not smoke. Do not spray on a naked flame or any incandescent material. Pressurized container: protect from sunlight and do not expose to temperatures exceeding 120 °F / 49 °C, i.e. electric lights. Do not pierce or burn, even after use.
·
Conditions for safe storage, including any incompatibilities
·
Storage:
·
Requirements to be met by storerooms and receptacles:
Store in a cool location. Observe official regulations on storing packagings with pressurized containers. Provide ventilation for receptacles. Avoid storage near extreme heat, ignition sources or open flame.
(Contd. on page 6)
40.1.3
Loading...