superior fires RADIUM, VERTIGO Installation And User Instructions Manual

superiorfires
UNCOMPROMISING QUALITY
RADIUM - VERTIGO
INSTALLATION AND USER INSTRUCTIONS
RADIUM
VERTIGO
This appliance is a high efficiency, flueless, flame effect gas fire. It provides radiant and convected warmth both effi­ciently and safely utilising the latest type catalytic convertor burner technology.
The appliance incorporates a combustion monitoring sys­tem (Oxygen Depletion System). It must not be adjusted or put out of operation. If replaced then manufacturers origi­nal parts must be used.
The appliance is designed to fit various types of situations as listed in the Installation Requirements.
This appliance must be installed in accordance with the rules in force and only used in a sufficiently ventilated space. A minimum of 100cm
2
(15.5in2) purpose provided ventilation is required for this appliance. An openable win­dow or louvre is also required. This appliance is factory set for operation on the gas type, and at the pressure stated on the appliance data plate.
The room size should be a minimum of 30m
3
(1059ft3) to allow adequate circulation of air and ensure the correct operation of the fire. This volume may include adjacent
spaces but these spaces must not be separated by a door. In order to convert from cubic feet (ft
3
) to cubic metres (m3)
divide the room volume (in ft
3
) by 35.3. This appliance is intended as a secondary source of heat only and should not be used in a room without some form of background heat­ing present.
The appliance must not be installed in a bedroom, bath­room or any sleeping area. The appliance does not require a flue system of any type as the catalytic converter cleans the flue products to provide a complete combustion sys­tem, which is intrinsically safe.
The appliance must be installed by a competent person in accordance with Gas Safety (Installation and Use) Regulations 1998 or rules in force. It is strongly recom­mended that a CORGI registered engineer is used for this purpose, as they are the only persons approved by the HSE under the above regulations.
On initial lightup of a new appliance, the ‘newness’ will burn off within the first few hours of operation. During this period some smoke may be emitted from outlet grille, this should be no cause for concern. Accordingly, the room should be well ventilated with all windows and doors open during this period.
Read all these instructions before commencing installation. All instructions must be handed to user for safekeeping.
1
INSTALLATION INSTRUCTIONS
This appliance is a catalytic flueless flame effect gas fire, providing radi­ant and convected warmth. It is designed to operate on Natural Gas fol­lowing factory set adjustments, (see Data Plate on appliance for gas type and pressure).
It is the LAW that all gas appliances and fittings are installed by a com­petent person (such as a CORGI registered fitter) and in accordance with the Gas Safety (Installation and Use) Regulations 1998, the rele­vant British Standards for Installation, Codes of Practice and the Manufacturers' Instructions. The installation shall also be carried out in accordance with the following regulations:
The Building Regulations issued by the Department of the Environment, the Building Standards (Scotland) (Consolidation) Regulations issued by the Scottish Development Department.
Relevant British standards insofar as the relevant areas are not covered by these instructions.
Note: For Republic of Ireland, reference should be made to the relevant standards governing installation. (IS 813: 1996)
Failure to comply with these regulations could lead to prosecution and deem the warranty invalid.
It should be noted that heaters create warm air currents. These currents move heat to wall surfaces next to the heater. Installing the heater next to vinyl or cloth wall coverings or operating the heater where impuri­ties in the air (such as tobacco smoke) exist, may discolour walls.
This appliance must be installed in accordance with the rules in force and used only in a sufficiently ventilated space. A minimum of 100cm
2
(15.5 in2) purpose provided ventilation is required for this appliance, an openable window or louvre is also required. To reduce the possibility of draughts entering the room via the air vent, we recommend the use of "Black Hole" or "Vortex" type vents featuring internal baffles.
Consult ALL instructions before installation and use of this appliance.
2
CONTENTS
Section Contents Page No.
1.0 Important Notes 2
2.0 Appliance Data 3
3.0 Installation Requirements 3
3.1 Room Sizing 3
4.0 Site Requirements 3
4.1 Ventilation 5
5.0 Unpacking the Appliance 5
5.1 Component Checklist 5
6.0 Gas Supply Routes 6
7.0 Preparing the Appliance 6
7.1 Fixing the Appliance 7
7.2 Checking the Burner 8
8.0 Testing and Commissioning 8
8.1 Operating the Appliance 8
8.2 Spark Failure 9
8.3 Setting pressure 9
8.4 Fitting the glass facia 9
9.0 Briefing the customer 10
10.0 Servicing 10
10.1 Servicing the Burner 11
10.2 Pilot Assembly 11
10.3 Catalysts 11
10.4 Testing for Firebox Leakage 12
11.0 Troubleshooting Guide 12
1.0 IMPORTANT NOTES
This appliance is free from any asbestos material.
This appliance may be installed with or without a hearth. If a hearth is fitted, the size and design may be as desired. If the appliance is to be sited near a disused natural draught flue it is recommended that the old flue should be partially sealed off to prevent draughts, however some ventilation will be required to prevent condensation.
The appliance is designed to be wall mounted. It is possible to install
the appliance onto certain types of combustible materials - see section entitled ‘Clearances to combustible materials’.
In the event that the fire is sited near a disused or unserviceable fire­place served by a natural draught flue, any existing under grate draught device should be sealed off to prevent loss of heat or creation of draughts. The passageway into the flue should be partially sealed to prevent excessive draughts, however some ventilation will be required in the old flue to prevent condensation and dampness. Advice should be sought from your local building control officer.
The room size should be a minimum of 30m3(e.g. 11’6” x 11’6” x 8’) to allow adequate circulation of air and ensure the correct operation of the fire. This volume may include adjacent spaces but these spaces must not be separated by a door. To calculate a room size in cubic metres (m3) divide the room volume in cubic feet (ft3) by 35.3.
This appliance is designed to be wall-hung. Do not recess any part of the appliance into the wall. This Appliance may be installed in any room in a home, however there are exceptions, and the appliance may not be used in the following rooms;
· Bedrooms - or areas which are mainly used for sleeping.
· Bathrooms - or areas where large amounts of steam are likely to be generated.
Installation in living rooms is common, however other rooms such as kitchens, dining rooms and hallways are permitted, providing a suitable natural gas supply is available, and rooms sizing and ventilation require­ments are strictly adhered to (see section 4.1).
The appliance is designed to be versatile, and as such will operate cor­rectly when exposed to normal gentle draughts experienced within the home. It is not recommended, however that the appliance be installed in areas where it is likely to be exposed to persistent strong draughts, that may be generated by outside doors or windows, air vents etc.
2.0 APPLIANCE DATA
3
Gas Group G20 Natural Gas CAT I2H Country(s) of destination GB/IE
Inlet Pressure 20 mbar Max Energy Input Gross 2.6 kW
Net 2.35 kW Max Gas Rate 0.25 m3/h Min Energy Input Gross 1.5 kW
Net 1.35 kW Pilot Energy Input Gross 166 W
Net 150 W Burner Pressure High 13.5 mbar. (+/-0.75 mbar). Hot
13.0 mbar. (+/-0.75 mbar). Cold
Low 4.2 mbar. (+/-0.25 mbar). Hot
3.7mbar (+/-0.25 mbar). Cold Main burner flow restrictor Stereo 1.30mm (1/4” BSP) Oxypilot SIT/Bray 9082 Gas Inlet Connection 8mm inlet restrictor elbow Ignition Piezo spark Spark Gap 4.0 mm (± 1.0mm)
Please see Data Badge affixed to appliance for current data. This appliance is for use only with the gas type, and at the pressure stated on the appliance Data Badge.
3.0 INSTALLATION REQUIREMENTS
3.1 ROOM SIZING
4.0 SITE REQUIREMENTS
It is recommended that the appliance should not be installed within 500mm of any air vent.
Clearances to non-combustibles
Non combustible surfaces are defined as brick, metal, marble, concrete etc. and also a number of man-made materials impervious to flame. If in doubt refer to the material manufacturer for further information before proceeding with installation.
Clearances to the sides of the appliance are 50mm (2in). Clearance to the front of the appliance is 500mm (20in).
The back of the appliance may be installed directly onto a non-com­bustible wall, providing the area behind the appliance is flat and does not interfere with the various vent holes in the back panel of the appli­ance.
The appliance may be installed with or without a non combustible hearth. If a hearth is fitted, the size and design may be as desired.
A non combustible shelf of any depth may be positioned above the appliance provided it is no closer than 400mm from the top of the appliance glass panel and the wall above the appliance is non com­bustible.
Clearances to combustible materials
Combustible materials are defined as wood, fabrics, or other materials likely to combust if exposed to flame. Generally, any material, which is likely to discolour, melt or misshape when exposed to moderate heat, should be considered as a combustible material or surface.
Clearance to the sides of the appliance are 100mm(4in) but curtains, drapes and other fabrics are not permitted within a distance of 500mm(20in) of the appliance sides. No such materials are permitted directly above the appliance regardless of distance.
The minimum clearance to the ceiling above the appliance is 800mm measured from the top of the appliance glass window panel (not the large glass facia).
Combustible materials should not be positioned directly in front of the appliance within a distance of one metre.
Under no circumstances should any electrical equipment e.g. plasma screen TV sets etc. be positioned on the wall above the appliance. The appliance is designed to be wall mounted alone and not in conjunction with any type of combustible fire surround. No combustible shelves should be positioned on the wall above the appliance. It should be established that any mirrors or picture frames etc. to be positioned on the wall above the appliance are able to withstand prolonged exposure to moderate heat and moisture before proceeding with their installa­tion.
The back of the appliance may be installed directly onto a combustible wall, providing it is relatively flat and does not interfere with the vari­ous vent holes in the back panel of the appliance. The wall must be structurally sound and constructed from a material capable of with­standing moderate heat. Finished plaster, conventional wall paper and dry-lined plasterboard are examples of suitable materials. Materials such as flock, blown vinyl and embossed paper which are sensitive to even small amounts of heat should be avoided as scorching and or dis­colouration may occur over time.
If the appliance is to be mounted on a dry lined wall or a timber framed construction wall then the integrity and ability of the wall to carry the weight of the appliance must be confirmed. It is important in these cir­cumstances that any vapour control barrier is not damaged, and that any structural members of the house frame are not damaged.
The appliance may be positioned as close to a solid floor (i.e. stone, wooden laminate etc.) as the particular design of fireframe permits, however it is not permitted to install the appliance within 100mm of carpet, rugs or fabric materials of any kind. This dimension is measured vertically to the bottom of the appliance frame.
4
4.0 SITE REQUIREMENTS - CONTINUED
A minimum of 100 cm2purpose provided ventilation is required for this appliance. This may be achieved either with one vent 100 cm2at a high or low position in the room, or split ventilation i.e. 50cm2be installed at high level and 50cm2be installed at low level within the room.
An openable window or equivalent is also required. The requirements of other flued appliance operating in the same room or space must be taken into consideration when assessing ventilation.
Any ventilation fitted must comply with BS 5871 part 2 and BS 5440 part 2. Ventilation fitted under, or within immediate vicinity (500mm) of the appliance must not be used as it may adversely effect perform­ance of the ODS system.
The appliance MUST NOT be installed in a bedroom, bathroom or any sleeping area. For Republic of Ireland, see relevant rules in force.
Remove the straps and the top lid of the outer packaging, remove any instructions or fixing kits. Read ALL these instructions before continu­ing to unpack or install this appliance.
Lift off the remaining packaging components. Check that the compo­nents supplied correlate with the component checklist. Please dispose of all the packaging materials at your local recycling centre.
QUANTITY DESCRIPTION
1 Firebox and burner assembly 1 Set of manufacturers instructions 1 Glass facia panel assembly 1 Curved rear frame (Radium models only) 4 Glass corner column (Vertigo models only) 1 Screw and wall plug pack 1 Rubber grommet 1 Fitting template
There are four possible entry points for the gas supply pipework to enter the appliance firebox. These entry points are ‘knock out’ type holes.
Non-concealed gas connections may be made using the entry points at either end of the firebox or the one in the bottom of the firebox. A con­cealed gas connection may be made using the knock out hole in the centre back of the firebox. Select the most appropriate entry point and knock out the relevant hole with a sharp tap from a hammer and fit the rubber grommet supplied. A small incision can now be made in the rubber to slip snugly around the outside of the supply pipe and sleev­ing.
In order to avoid unnecessary pressure drops, no more than 1.5m of 8mm diameter pipe must be used.
If a concealed gas connection is to be made, the supply pipe should always be sleeved through walls and floors using the shortest possible route.
For concealed supply pipe routing, pipes must (where possible) be ver­tical and providing there is sufficient wall thickness available, they should be placed in pipe chases. Horizontal pipe runs should be avoid­ed. Prior to chasing a solid wall, an inspection should be made to note the proximity of any cables/sockets outlets which may already be buried.
4.1 VENTILATION
5
5.0 UNPACKING THE APPLIANCE
5.1 COMPONENT CHECKLIST
6.0 GAS SUPPLY ROUTES
Pipes must be secured using suitable clips and protected against corro­sion. Ideally factory finished protected pipework and fittings should be used. Joints should be kept to a minimum and compression fittings must not be used. The pipework installation must be tested for sound­ness before any protection is applied and/or the pipework and fittings are buried.
Radium models : The curved rear frame is supplied pre-assembled to the appliance - no further preparation is necessary.
Vertigo models :
1. Firstly remove the two retaining screws on each side of the upper
grille and remove the grille from the outer casing.
2. Remove the two retaining nuts from the retaining studs that pro­trude into the lower part of the main firebox as shown. The control knob is located on the lower right hand side of the outer casing, and is mounted in an indicator bracket, which has a metallic indication ‘pip’. Both the knob and the indicator bracket should be removed as follows;
3. Remove the retaining pin from the gas valve spindle and withdraw the control knob and the spindle extension from the right hand side of the appliance.
4. Remove the four retaining screws and the indicator bracket. The main firebox may now be detached from the outer casing.
6.0 GAS SUPPLY ROUTES
6
7.0 PREPARING THE APPLIANCE
Remove retaining nuts
1. Remove the Grille
2. Remove retaining nuts
VERTIGO MODELS : PREPARING THE APPLIANCE
3. Remove spindle retaining pin
4. Remove control indicator bracket and control knob
After having selected the final mounting position of the appliance, tak­ing into account the site requirements as specified in section 4 of these instructions, the integrity of the wall, and the feasibility of the proposed supply pipe routing, the firebox of appliance may be secured to the wall. A fitting template is supplied to assist with this.
Vertigo models : Mark the positions shown as “Vertigo box min. fix­ing points” on the wall. Due to the weight of the glass panel, it is pos­sible to fix the outer casing to the wall in up to nine positions, depend­ing on the strength/condition of the wall. If in doubt always use
extra fixings!
If the appliance is to be mounted on the inner leaf of a conventional cavity wall, or a solid wall, drill four holes using a 7mm masonry bit. Insert the fibre wallplugs provided.
If the appliance is to be mounted on a dry lined wall or a timber framed construction wall then special cavity screw fixings will be required which are not supplied with this product. These should be constructed from metal and not plastic.
Insert the screws into the upper two holes, leaving 5mm protruding from the wall. Temporarily hang the outer casing on the wall, and mark any additional fixing points as required. Remove the outer casing from the wall and drill holes for the additional fixing points as required. Insert either wall plugs or cavity screw fixings as required. Re-position the outer casing on the wall and using a spirit level to check the casing is square and level, tighten all of the fixing screws fully.
Now, with the outer casing fixed to the wall, the main firebox can be secured in position. The firebox is held on the outer casing using four studs and four nuts. Make sure that the upper nuts are un­screwed approximately one turn from the fully tightened position in order to create a 2mm gap as shown. The firebox may now be hung onto the top studs, and then pushed onto the lower studs so that the lower studs protrude through the lower fixing holes in the back panel of the firebox. Tighten the lower fixing nuts on to the lower fixing studs fully.
Next, re-fit the grille, the indicator bracket and the control knob and spindle, and secure in position using the correct fixing screws (re-fitting is the opposite of removal as detailed in section 7.0 of these instruc­tions).
Radium models : Mark the positions shown as “Radium fixing points” on the wall. If the appliance is to be mounted on the inner leaf of a conventional cavity wall, or a solid wall, drill four holes using a 7mm masonry bit. Insert the fibre wallplugs provided.
If the appliance is to be mounted on a dry lined wall or a timber framed construction wall then special cavity screw fixings will be required which are not supplied with this product. These should be constructed from metal and not plastic.
7.1 FIXING THE APPLIANCE
7
2mm
If a concealed gas connection is to be made ensure the gas supply pipe is in it’s final position and can enter the appliance in the correct posi­tion when the appliance is hung on the wall.
Insert the wall fixing screws into the top wall plugs, taking care to leave the screws protruding approximately 5mm from the wall. Now hang the appliance onto these screws through the two keyhole shaped holes in the back panel of the appliance.
Insert the lower fixing screws into the lower wall plugs through the cor­responding depressed holes in the lower part of the back panel. Do not tighten fully.
Before tightening the wall mounting screws fully, at this stage it is rec­ommended to check the horizontal alignment of the appliance with a spir­it level, as small adjust­ments can still be made if necessary. When this has been checked, tighten all four fixing screws fully.
To access the upper fixing screws insert a screwdriv­er through the holes in the deflector plates above the catalyst as shown above.
There are no imitation fuel bed components to install. The appliance features a ribbon burner which is designed to produce a continuous band of flame over it’s length. The burner should be visually inspected to ensure it is free from any foreign matter. If it is necessary to clean or dust off the burner then the glass door should be removed by removal of the retaining screws. Re-fit the glass door after cleaning or inspection, ensuring a good seal.
Turn on and test the gas supply up to the fire for any leaks, in accor­dance with the current edition of BS6891.
The pilot is visible behind the left hand side of the burner.
Vertigo models : The con­trol knob is located on the lower right hand side of the outer case. It is of a spheri­cal design and is marked as shown in the diagram to the left;
Radium models : The con­trol knob is located in the centre of the appliance and is normally accessed by swinging the glass panel upwards from the bottom. The glass panel is not fitted until section 8.4.
All models : Push in and turn the control knob to the SPARK position, and hold there for a few seconds. Continue turning anti-clock­wise through the spark click to the PILOT light position, ensuring the pilot has lit. If not, return the knob clock­wise, and repeat. When the pilot lights after the spark, keep the knob depressed for approximately ten seconds.
8
7.2 CHECKING THE BURNER
8.0 TESTING AND COMMISSIONING
8.1 OPERATING THE APPLIANCE
‘OFF’ position
‘SPARK’ position
‘LOW’ position
‘HIGH’ position
Vertigo models
Radium models
7.1 FIXING THE APPLIANCE
- CONTINUED
Now release the knob and the pilot should stay alight. If the pilot is extinguished during use, wait three minutes before repeating the igni­tion procedure. To achieve the HIGH setting, push the control knob in slightly and continue turning anti-clockwise to the high position. The main burner should light after a few seconds. To decrease the setting to LOW, turn the control knob clockwise to the low setting. To turn to the PILOT position from the HIGH or LOW positions, press the control knob in, and return to the pilot position and release. To turn the fire OFF, keep the knob pressed in, return to the off position and release.
The gap between the spark electrode and the pilot should be 3 - 5mm to produce a good spark. There should be no need to adjust this. If under any circumstances the piezo electric spark fails, the pilot cannot be lit manually.
The pressure test point is located on the left hand side of the appliance, on the main burner pipe, next to the brass restrictor/connector. Release the setting pressure test point screw, and attach a U gauge. Light the fire on the HIGH setting.
To commission the appliance, the burner pressure must be in accor­dance with the figures stated in the data section of these instructions. The fire is factory set to achieve these pressures and any significant vari­ation could indicate a supply problem. If the pressure is too high, the gas supply meter may be set incorrectly. This should be checked with the fire running and if necessary reset by the gas supplier. If the burner pressure is too low, then check the inlet pressure with the appliance running. If this is less than approximately 20mbar it will need to be reset by the gas supplier. If the setting pressure is too low, but the meter pressure is acceptable, then a problem in the supply pipework is to be suspected. This will be dirt and debris, kinked or inadequate size pipes, restriction in a fitting, shut off elbow not fully open or solder flashing across a joint. Identify the cause of the restriction and rectify. Switch the fire off,
disconnect the U gauge and refit the test nipple screw. Light the fire and check for gas soundness. In the event that the burner pressure is not in accordance with the fig­ures stated in the data section of these instructions, the appliance must not be commissioned, and the manufacturer should be contacted for guidance.
Vertigo models : The glass panel is supported by four M6 screws which protrude from the front of the outer casing. Ensure each screw is unscrewed approximately one turn from the fully screwed in position in order to create a 2mm gap (shown). Simply hang the glass panel onto the outer casing ensuring that the corresponding keyhole shaped holes engage the screwheads fully.
With the appliance and main glass facia mounted in position on the wall, remove tape and unscrew the front clamping disc, and remove.
Compress the column assembly and position behind the glass panel, lining up with the appropri­ate hole. Release the assembly when in position and secure in place by refitting the front clamping disc.
9
8.1 OPERATING THE APPLIANCE
- CONTINUED
8.2 SPARK FAILURE
8.4 FITTING THE GLASS FACIA
8.3 SETTING PRESSURE
Compress the
assembly
Front clamping disc
Radium models : The glass panel is sup­ported by two self-locking M6 screws, one on each side of the fire. The glass panel must be held in position while the screws are inserted on each side - it is recommended to seek assistance for this operation.
The screws should be screwed in fully and then undone one turn. to allow the glass panel to swing open for access to the controls.
The appliance features a hinge assembly which is supplied pre-assembled. The hinge assembly should be fitted onto the rear of the glass facia, on the lower right hand side as follows;
1) Before fitting the glass facia to the fire, attach the short end to the bracket on the rear of the glass facia using the screw, nut and nylon washer pro­vided.
2) Attach the long end of the hinge to the stud as shown. Secure using the nut provided. All nuts should be tightened fully, and then released one quarter of a turn.
All instructions must be handed to the user for safekeeping. Show the customer how to light and control the fire.
After commissioning the appliance, the customer should be instructed on the safe use of the appliance and the need for regular servicing. Frequency of service depends on usage, but MUST be carried out at least once annually. Advise that cleaning of the fire may be achieved when the fire is cold using a damp cloth and mild detergent on most surfaces. Advise that the fire will emit a "newness" smell for a time after initial commissioning and that extra ventilation may be needed during this time. Recommend that a guard be used for the protection of the young, pets, the elderly and the infirm.
Isolate the fire from the gas supply. Ensure that the fire is fully cold before attempting service. A suggested procedure for servicing is detailed below.
1. Lay out the dustsheet and tools.
2. Remove the front section of the frame by following section
8.4
3. Remove the glass door assembly and clean carefully.
4. Inspect the burner and the catalysts and clean if necessary with a soft brush.
5. Disconnect the gas supply.
6. Undo the four screws retaining the burner support brackets to the base and rear of the firebox.
7. Remove the burner unit, strip off the burner pipes and clean thoroughly.
8. Clean the in-line restrictor, pilot assembly and the burner
tube. Do not attempt to remove the pilot injector as this can
cause damage.
9. If the ceramic tiles (if fitted) need to be removed for clean ing, then undo the two screws inside the top of the firebox and remove the retaining brackets. The tiles are fragile and should not be removed unless necessary.
10. Re-assemble components.
11. Turn on the gas supply and leak test. Check pilot and
burner for good ignition.
12. Refit the glass door assembly, ensuring a good seal.
13. Refit the casing. Refitting is the reverse of removal.
14. Check the purpose provided ventilation is un-obstructed.
15. Light the fire and test setting pressures.
16. Check safe operation of the appliance.
For specific servicing instructions, see relevant sections.
10
8.4 FITTING THE GLASS FACIA
- CONTINUED
9.0 BRIEFING THE CUSTOMER
10.0 SERVICING
M4 nyloc nut
Nylon washer
Retaining stud
M4 screw
Firstly, remove the main glass panel, following section 8.4, and discon­nect the gas connection inside appliance. The gas connections to the gas valve can now be released. Undo the four screws retaining the burner support brackets to the base and rear of the firebox. The burn­er may now be removed.
Remove the pilot and main burner pipes and blow through to dislodge any debris. Now remove the injector elbow and blow through to make sure it is entirely clear.
Unclip the pilot lint gauze and clean with a soft brush. Clean the exte­rior of the pilot assembly with a soft brush and blow through the flame ports on the pilot head. Check the aeration holes are free from lint or dirt. The pilot assembly can be removed if required by disconnecting the electrode HT lead, gas pipe and unscrewing the mounting screws and lifting away.
The pilot assembly is a non-serviceable item and should not be taken apart. Aeration holes must be absolutely clear internally for proper operation. NEVER MODIFY OR BEND THE THERMOCOUPLE TO MAKE THE PILOT STAY ALIGHT. Modifications are dangerous and can have serious unseen effects on safety. If the pilot will not stay lit there is a problem with dirt, the gas supply to it, or the thermocouple needs replacement.
The gas valve is a non-serviceable item. If this needs replacement, remove the data badge then the M5 securing screw holding the valve bracket in place, remove all pipe unions, and the complete valve. Replacement must be original manufacturers parts. Re-assemble in the reverse of removal. Ensure setting pressures are as stated in Section 2; Appliance Data.
Remove the casing, internal firebox (as per servicing section), lint arrestor and pilot unit by using a screwdriver to remove the retaining screws. Clean the pilot assembly with a soft brush and blow through. Check the aeration holes are free of any dirt or lint. Clean thoroughly inter­nally, the connection can be removed from the base of the pilot unit using two spanners to make cleaning easier. Do not damage or try to dismantled the pilot injector.
The unit is factory set and the only check necessary is to ensure the spark gap is correct. See specifications for gas setting.
NEVER MODIFY OR BEND THE THERMOCOUPLE TO MAKE THE PILOT STAY ALIGHT. If the pilot will not stay lit there is a problem with
dirt, the gas supply, or the thermocouple needs replacement. Modifications are dangerous and can have a serious unseen effect on safety and therefore MUST not be done. Replacements must be origi­nal manufacturers parts. Re-assemble in the reverse of removal. Ensure setting pressures are as stated in Section 2; Appliance Data.
It is recommended that the catalysts are inspected for signs of damage and dirt during routine servicing procedures. The expected life of the catalysts is in excess of 11,000 hours (10 years of normal use). After this time the catalyst should be replaced.
If there are any deposits of dirt or soot on the catalysts they should be cleaned with a soft brush and a vacuum cleaner. If removed for clean­ing ensure the seals are in good condition before replacing the catalyst. New seals will usually be required.
The performance of the catalyst may be checked using a combustion gas analyser as follows. Any analyser used should conform to BS7927 : 1998 + A1 : 1999.
10.1 SERVICING THE BURNER
11
10.2 PILOT ASSEMBLY
10.3 CATALYSTS
Important: The temperature of the gas emmited by the catalytic converter is in excess of 350
o
C. Measuring gas of this tempera­ture may damage some types of gas analysers. If in doubt con­sult the equipment manufacturer.
Ignite the fire as per the operating instructions, and run at maximum setting for 15 minutes. Position gas sample probe directly over the cat­alyst via the outlet grille, on top of the appliance. Record the carbon dioxide (CO
2
) concentration and then the carbon monoxide (CO) con­centration as displayed by the analyser - also noting the units in which the values are expressed.
Most analysers display carbon dioxide (CO
2
) concentrations in percent­age (%) terms and carbon monoxide concentration in parts per million (ppm) terms.
In order to calculate the combustion ratio for the appliance (CO/CO
2
) it is first necessary to express both gas concentrations in terms of per­centage. To convert from parts per million (ppm) to a percentage (%) divide the ppm figure by 10,000. Examples : 35ppm = 0.0035%, 15ppm = 0.0015%, 5ppm = 0.0005%.
Now divide the concentration of carbon monoxide (CO) expressed in percent by the concentration of carbon dioxide (CO2) to obtain the appliance combustion ratio.
The combustion ratio of the gasses emitted by the catalytic con­vertor should not exceed 0.0015.
If replacing, firstly, remove the decorative fireframe as described in sec­tion 5.2. The catalysts are located on the top of the internal firebox and can be removed be unscrewing the retaining nuts securing the clamp­ing plate. Remove the catalyst and its seal and discard. Refit a new cat­alyst and seals in reverse order, ensure the catalysts and door have a good seal.
Appliances that are several years old or have been extensively disman­tled should be checked for soundness. It is important that all the products of combustion pass through the catalytic converter at the top of the firebox before leaving the appliance.
The firebox is heated by lighting for a few minutes to provide a flow through the firebox. The burner is then shut off and a smoke pellet or match introduced at the base of the fire underneath the burner tray. Large quantities of smoke will emerge from the top of the appliance, but none should emerge from the joints or gasket faces, especially around the door. It is important to note that the appliance can never be expected to be 100% smoke tight and small quantities of smoke may be seen in corners of joints and gasket faces etc without affect­ing safety when the fire is in operation.
Fire sparks No gas to fire, check isolators are open. but pilot Pipe work blockage, clean out. does not light Air not fully purged, re purge supply or wait
longer. Spark earthing to metal work, reset gap cor­rectly. Blocked pilot, clean out internally.
Pilot lights but Severe restriction in gas supply: clear then goes out obstruction.
Faulty thermocouple, replace pilot unit. Blocked pilot, clean out. Blocked lint gauze, clean. Hold control knob in for longer. Check control knob does not foul data plate. If the pilot will not stay lit there is a problem with dirt, the gas supply, or the thermocou­ple needs replacement. Modifications are dangerous and can have a serious unseen effect on safety. NEVER MODIFY OR BEND
THE THERMOCOUPLE TO MAKE THE PILOT STAY ALIGHT.
10.3 CATALYSTS
- CONTINUED
12
CO (%) CO
2
(%) = ratio
10.4 TESTING FOR FIREBOX LEAKAGE
10.5 TROUBLESHOOTING GUIDE
Fire does not HT lead detached, refit. spark at pilot Check the spark gap (see section 8.2).
Faulty piezo unit, replace. Debris shorting out electrode, clean. Spark shorting to metalwork under tray, realign HT lead.
Fire runs for a Loose or faulty thermocouple, rectify. time and then Blocked pilot, clean out. cuts off Dirt or lint in pilot aeration hole or on the
lint gauze, clean thoroughly. If the pilot will not stay lit there is a problem with dirt, the gas supply, or the thermocou­ple needs replacement. Modifications are dangerous and can have a serious unseen effect on safety. NEVER MODIFY OR BEND
THE THERMOCOUPLE TO MAKE THE PILOT STAY ALIGHT.
Pilot flame shrinks Poor gas flow to fire, check pressure with when fire is fire on high. on high If pressure is low, remove any restriction in
pipework or valve. Check all isolators are adequately sized and fully open. Check meter pressure is adequate. If the pilot will not stay lit there is a problem with dirt, the gas supply, or the thermocou ple needs replacement. Modifications are dangerous and can have a serious unseen effect on safety. NEVER MODIFY OR BEND
THE THERMOCOUPLE TO MAKE THE PILOT STAY ALIGHT.
Fire smells when Newness smell from brand new appliance. first lit or in use Leakage occurring. Carry out leakage test
and rectify any problems. Combustible materials used in incorrect posi tions.
13
10.5 TROUBLESHOOTING GUIDE
- CONTINUED
Section Content Page No
1.0 Important Notes 1
2.0 Clearances to Combustibles 1
3.0 Ventilation & Room Size 2
4.0 Operating Instructions 3
5.0 Combustion Monitoring System 3
6.0 Cleaning 4
7.0 Servicing 4
8.0 List of Replacement Parts 4
The installation and Servicing of this fire MUST only be carried out by a competent person (such as a CORGI registered fitter) in accordance with the Gas Safety (Installation and Use) Regulations 1998, the rele­vant British Standards, Codes of Practice, the Building Regulations and the manufacturer's instructions.
Failure to comply with the above recommendations could lead to pros­ecution and invalidate the appliance warranty.
Always keep a note of the installer's name and address, CORGI regis­tration number, the original purchase receipt and the date of installa­tion for future reference. Failure to produce these documents may invalidate the warranty.
The appliance should be serviced regularly to ensure continued safe operation. See the servicing section for further reference.
Parts of this appliance become naturally hot during use. It is recom­mended that a suitable fireguard conforming to BS 8423 is used, espe­cially where young children, pets, the elderly or infirm are concerned.
The manufacturer of this appliance considers all surfaces as working surfaces with the exception of the control knob, control panel, and the lower part of the glass facia (Radium models).
Combustible items, such as flooring and furniture and soft wall cover­ings (such as blown vinyl or embossed paper), low temperature sur­rounds etc may discolour if fitted too close to the fire. See relevant sec­tion for further details on clearances to combustibles. No combustible materials or flooring should protrude onto the hearth (if fitted).
This appliance incorporates a combustion monitoring system (ODS).
DO NOT burn any foreign material on this fire. Under no circumstances shall the appliance be used if the glass front door or panel has been removed, damaged or is open.
Do not place any objects on top of the appliance.
The integral catalyst should be checked by the installer upon servicing to ensure there are no defects or obstructions that may prevent the sat­isfactory flow of combustion products.
The expected life of the catalyst is in excess of 11,000 hours (10 years of normal use). After this time the catalyst should be replaced.
This appliance is only suitable for the gas type for which it is supplied.
WARNING: Due to the nature of this product the area around the top of the appliance (i.e. the grille) gets very hot. Care should be taken when operating the appliance.
Clearances to combustible materials
Combustible materials are defined as wood, fabrics, or other materials likely to combust if exposed to flame. Generally, any material, which is likely to discolour, melt or misshape when exposed to moderate heat, should be considered as a combustible material or surface.
Clearance to the sides of the appliance are 100mm (4in) but curtains, drapes and other fabrics are not permitted within a distance of 500mm (20in) of the appliance sides.
1.0 IMPORTANT NOTES
1
USER’S INSTRUCTIONS
2.0 CLEARANCES TO COMBUSTIBLES
No such materials are permitted directly above the appliance regardless of distance.
The minimum clearance to the ceiling above the appliance is 800mm measured from the top of the appliance glass window panel (not the large glass facia).
Combustible materials should not be positioned directly in front of the appliance within a distance of one metre.
Under no circumstances should any electrical equipment e.g. plasma screen TV sets etc. be positioned on the wall above the appliance. The appliance is designed to be wall mounted alone and not in conjunction with any type of combustible fire surround. No combustible shelves should be positioned on the wall above the appliance. It should be established that any mirrors or picture frames etc. to be positioned on the wall above the appliance are able to withstand prolonged exposure to moderate heat and moisture before proceeding with their installa­tion.
The back of the appliance may be installed directly onto a combustible wall, providing it is relatively flat and does not interfere with the vari­ous vent holes in the back panel of the appliance. The wall must be structurally sound and constructed from a material capable of with­standing moderate heat. Finished plaster, conventional wall paper and dry-lined plasterboard are examples of suitable materials. Materials such as flock, blown vinyl and embossed paper which are sensitive to even small amounts of heat should be avoided as scorching and or dis­colouration may occur over time.
The appliance may be positioned as close to a solid floor (i.e. stone, wooden laminate etc.) as the particular design of fireframe permits, however it is not permitted to install the appliance onto carpet, rugs or fabric materials of any kind. In a situation where the appliance is installed at floor level in a carpeted room or space with a fabric floor covering then a non combustible hearth with a minimum projection into the room of 100mm and a minimum width of 820mm must be used.
Clearances to non-combustibles
Non combustible surfaces are defined as brick, metal, marble, concrete etc. and also a number of man-made materials impervious to flame. If in doubt refer to the material manufacturer for further information before proceeding with installation.
Clearances to the sides of the appliance are 50mm (2in). Clearance to the front of the appliance is 500mm (20in).
The back of the appliance may be installed directly onto a non-com­bustible wall, providing it is relatively flat and does not interfere with the various vent holes in the back panel of the appliance.
The appliance may be installed with or without a non combustible hearth. If a hearth is fitted, the size and design may be as desired.
A non combustible shelf of any depth may be positioned above the appliance provided it is no closer than 400mm from the top of the appliance glass panel.
Purpose provided ventilation of 100cm
2
is required for this appliance.
An openable window or equivalent is also required.
Any ventilation fitted must comply with BS 5871 part 2 and BS 5440 part 2. Ventilation fitted under, or within immediate vicinity of the appliance must not be used as it may adversely effect performance of the combustion monitoring system (ODS) system.
The requirements of other appliances operating in the space or room must be taken into consideration when assessing ventilation require­ments, this will have been carried out by your CORGI registered installer.
A supply of fresh air into the room is advisable to maintain tempera­tures within limits.
2
2.0 CLEARANCES TO COMBUSTIBLES
- CONTINUED
3.0 VENTILATION AND ROOM SIZING
The appliance MUST NOT be installed in a bedroom or bathroom.
For Republic of Ireland, see relevant rules in force.
The room size should be a minimum of 30m
3
(e.g. 11’6” x 11’6” x 8’) to allow adequate circulation of air and ensure the correct operation of the fire. This volume may include adjacent spaces but these spaces must not be separated by a door. To calculate a room size in cubic metres (m
3
) divide the room volume in cubic feet (ft3) by 35.3. This appliance is intended as a secondary source of heat only and should not be used in a room without some form of background heating pres­ent.
The pilot is visible behind the left hand side of the burner.
Vertigo models : The con­trol knob is located on the lower right hand side of the outer case. It is of a spheri­cal design and is marked as shown in the diagram to the right;
Radium models : The con­trol knob is located in the centre of the appliance and is accessed by swinging the glass panel upwards from the bottom.
All models : Push in and turn the control knob to the SPARK position, and hold there for a few seconds. Continue turning anti-clockwise through the spark click to the PILOT light position, ensuring the pilot has lit. If not, return the knob clock­wise, and repeat.
When the pilot lights after the spark, keep the knob depressed for approximately ten seconds.
Now release the knob and the pilot should stay alight. If the pilot is extinguished during use, wait three min­utes before repeating the ignition procedure. To achieve the HIGH setting, push the control knob in slightly and continue turn­ing anti-clockwise to the high position. The main burner should light after a few seconds. To decrease the setting to LOW, turn the control knob clockwise to the low setting. To turn to the PILOT position from the HIGH or LOW positions, press the control knob in, and return to the pilot position and release. To turn the fire OFF, keep the knob pressed in, return to the off position and release.
This fire is fitted with a combustion monitoring safety device (ODS). If the appliance shuts down during use for no apparent reason then sev­eral reasons may be suspected. If a door or window has been opened creating a draught, then pilot disturbance could be the problem and removal of the draught should resolve this. The appliance can then be re-lit in accordance with the previous section.
If pilot disturbance is not the cause, then the ODS safety system may be in operation. Switch the appliance OFF, call in your installer to check the appliance and ventilation. Remedial work must be carried out as required. DO NOT allow the appliance to be used until the appliance and installation is passed as safe. If the pilot continues to be extin­guished, you must call your installer to check the operation of the com­plete appliance.
3
3.0 VENTILATION AND ROOM SIZING
- CONTINUED
4.0 OPERATING INSTRUCTIONS
‘OFF’ position
‘SPARK’ position
‘LOW’ position
‘HIGH’ position
Vertigo models
Radium models
5.0 COMBUSTION MONITORING SYSTEM
Before carrying out any of the following operations, ensure that the appliance is OFF and completely cold. GLASS PANEL - This can be cleaned with a suitable glass cleaner. Test on a small area first. PAINTED AREAS - These can be cleaned using a dry cloth. FINISHED METAL AREAS - These can either be cleaned using a propri­etory metal cleaner or baby oil. Test on a small hidden part before cleaning. Always clean in the direction of the grain.
The appliance should be checked on an annual basis to ensure it is working safely and that there is no excessive build up of soot. The fre­quency of service will depend on usage, but MUST be carried out at least once annually. Servicing must be carried out by a competent per­son, such as a CORGI registered installer.
The Installation instructions carry full servicing details for the use of the installer.
PART NO. ITEM
Please Enquire Glass door assembly FT/F730023 Pilot assembly Please Enquire Gas valve Please Enquire Burner unit FB/F940136 Catalyst FB/F940136 Seal kit for Catalyst
6.0 CLEANING
4
7.0 SERVICING
8.0 LIST OF SPARE PARTS
As our policy is one of continuous improvement and development , we hope therefore you will understand we must retain the right to amend details and/or specifications without prior notice.
Model :
Date installed :
Supplied by :
Fire serial No. :
Name of installer :
Corgi Reg. no. of installer :
9.0 INSTALLATION DETAILS
10.0 SERVICE HISTORY
Date of service Serviced by : Corgi Reg. no. of Engineer
Superior Fires, Christchurch, Dorset BH23 2BT
www.superiorfires.com
e-mail: sales@superiorfires.com
DO 005565/0
All instructions must be handed to user for safekeeping
Revision B - 10/05