superior fires CLARA LED INSET ELECTRIC FIRE, NDY-19, LONDRA LED REFLECTIONS INSET ELECTRIC FIRE Installation & User's Instructions

INSTALLATION & USER INSTRUCTIONS
MODELS COVERED BY THESE INSTRUCTIONS
NDY-19
CLARA LED INSET ELECTRIC FIRE
LONDRA LED REFLECTIONS INSET ELECTRIC FIRE
FRET AND FRAME OPTIONS AVAILABLE
LED ELECTRIC FIRE
Revision D - 12/17
GB IE
MODEL SHOWN: CLARA LED INSET ELECTRIC FIRE
Image used for illustration puposes only
All instructions must be handed to the user
for safekeeping.
Please note : Except where otherwise stated, all rights, including copyright in the text, images and layout of this booklet is owned by Focal Point Fires plc. You are not permitted to copy or adapt any of the content without the prior written permission of Focal Point Fires plc.
©
2017 Focal Point Fires plc.
This product is only suitable for well insulated spaces or occasional use.
Superior Fires
Christchurch, Dorset BH23 2BT
Tel: 01202 588 632 Fax: 01202 499326
www.superiorfires.co.uk
Email : sales@superiorfires.co.uk
1.0 PRELIMINARY NOTES
I N S TA L L AT I O N & U S E R I N S T RU C T I O N S
GB IE
Section Contents Page No.
1.0 Preliminary Notes 2
2.0 Installation Requirements 3
3.0 Appliance Data 3
4.0 Unpacking the Appliance 4
5.0 Component Checklist 5
6.0 Installing the Appliance 5
7.0 Removing the Appliance Spacer Frames 6
Section Contents Page No.
8.0 Fitting the Decorative Frame and Front 6
8.1 Fitting the Loose Fuel Bed Options 7
9.0 Operating the Appliance 7
10.0 Safety Cut-Out System 11
11.0 Cleaning and Maintenance 11
12.0 Servicing 12
13.0 Guarantee - Terms and Conditions 12
IMPORTANT - THESE INSTRUCTIONS SHOULD BE READ CAREFULLY
AND RETAINED FOR FUTURE REFERENCE.
The appliance is designed for indoor use, and can be simply floor mounted in the majority of floor positions anticipated. It can be located in any household room, with the exception of bathrooms. Read all of the instructions before commencing installa­tion. Retain for future reference and pass on as necessary to subsequent owners of the appliance.
DO NOT use this appliance immediately below a fixed socket outlet.
DO NOT use this appliance in an open flue. When using this electrical appliance, basic precautions should be followed to reduce the risk
of fire, electric shock and injury to person, including the following:
• This heater must be used on an AC supply only and the voltage marked on the heater’s rating label must correspond to the supply voltage.
DO NOT switch the appliance on until it is properly installed as described in this manual.
• This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
• Children of less than 3 years should be kept away unless continuously supervised. Children aged from 3 years and less than 8 years shall only switch on/off the appliance pro­vided that it has been placed or installed in its intended normal operating position and they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children aged from 3 years and less than 8 years shall not plug in, regulate and clean the appliance or perform user maintenance.
CAUTION: Some parts of this product can become very hot and cause burns. Particular attention has to be given where children and vulnerable people are present.
• If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
• The heater must not be located immediately below a socket-outlet.
DO NOT use this heater in the immediate surroundings of a bath, a shower or a swim- ming pool, or other area where water/moisture could present a hazard.
WARNING: In order to avoid overheating, do not cover the heater.
DO NOT use this heater with a programmer, timer, separate remote-control system or any other device that switches the heater on automatically, since a fire risk exists if the heater is covered or positioned incorrectly.
CAUTION: In order to avoid a hazard due to inadvertent resetting of the thermal cutout, this appliance must not be supplied through an external switching device, such as a
© 2017 Focal Point Fires plc.
DO NOT - site in a position where curtains or drapes could cover the appliance.
- site in a position where other soft materials could cover e.g. below a coat rack.
- site behind an opening door where mechanical impact/damage could occur.
- site where the supply cable would become a trip hazard.
- sit, stand or forcefully pull on the appliance.
- obstruct, cover or force items into the openings.
- use the heater to dry clothes.
- site/use in an outdoor location(s).
- run the supply cable under carpets.
- Mount on a wall.
DO NOT run the mains cable under carpets, rugs etc.
DO NOT cover or obstruct the heater in any way. Overheating will result if it is acci- dentally covered.
• Never immerse the product in water or any other liquids.
DO NOT use the appliance outdoors.
• Before cleaning the appliance, ensure it is unplugged from the power and that it is com­pletely cool.
DO NOT clean the appliance with abrasive chemicals.
• Never use accessories that are not recommended or supplied by the manufacturer. It could cause danger to the user or damage to the appliance.
DO NOT insert or allow foreign objects to enter the inlet or outlet vents as this may result in electric shock, fire or damage to the appliance.
DO NOT install the fire using an extension cord.
• Unplug from the mains supply if the appliance is not to be used for long periods.
• This product is only suitable for well insulated spaces or occasional use.
timer, or connected to a circuit that is regularly switched on and off by the utility.
• Keep furniture, curtains and other fabric material away from the appliance.
DO NOT leave the appliance unattended during use.
• From time to time, check the cord for damage. Never use the appliance if the cord or any part of the appliance shows signs of damage.
1.0 PRELIMINARY NOTES - CONTINUED
GB IE
3.0 APPLIANCE DATA
Weight (kg): 14 kg Voltage (Volts): 220-240V a.c. 50Hz Rated Power 2 x 900W/ 2 x 1000W Supply Plug: BS 1363, 13A Fused Supply Cord: 1.7 Metres Location: Indoor Use LED Display: 4 Watts
This product is only suitable for well insulated spaces or occasional use. The appliance is supplied with a pre-wired three pin plug (13 Amp fuse rated) and 1.7 metres of electrical cable. It is therefore necessary for a suitable electrical socket to be located within this distance and be eas­ily accessible. The appliance is suitable for installation into all proprietary surrounds with an opening of 406mm by 559mm (16” by 22”). The appliance is supplied fitted with 2 spacer frames enabling it to be fitted with no need for a recess into a wall or surround back panel. Both spac­er frames have a depth of 57mm. The appliance can be fully recessed if the opening depth is 113mm or greater and neither spacer is used. It may be installed directly into any proprietary surround which can house this size of rebate, without the need to recess the appliance into a wall opening or fabricate a false chimney breast.
This appliance should be positioned on a firm level surface and in a clean ‘dust free’ environment. If the fire is to be sited in a fire surround then the suitability of the surround for use with electrical heaters should be established with the fire surround manufacturer. If fitted into an open draught fireplace, it is recommended to blank off the chimney to reduce the risk of draught through the fire, which may cause the safety cut out system in the fan heater to operate.
2.0 INSTALLATION REQUIREMENTS
© 2017 Focal Point Fires plc.
Read all the instructions before continuing to unpack or install this appliance. Carefully remove the appliance from its packaging and lay on the floor with it’s back surface downward. Note: DO NOT stand the appliance on its frame as this may cause distortion. Check that the remaining packaging contents correlate with the component checklist below. Please dispose of all packaging with care at your local recycling centre.
4.0 UNPACKING THE APPLIANCE
3.0 APPLIANCE DATA - CONTINUED
GB IE
© 2017 Focal Point Fires plc.
All Models NDY-19
Item Symbol Value Unit Item Unit
Heat output Types of heat input, for electric storage local
space heaters only
Nominal heat output
Pnom 1.9 KW Manual heat charge control with
integrated thermostat
N/A
Minimum heat output (indicative)
Pmin 0.95 KW Manual hear charge control with
room and/or outdoor temperature feedback
N/A
Maximum continuous heat output
Pmax, c 1.9 KW Electronic heat charge control with
room and/or outdoor temperature feedback
N/A
Auxiliary electricity consumption Fan assisted heat output N/A
At nominal heat output
elmax 0.014 KW Type of heat output/room temperature control
At minimum heat output
elmin 0.014 KW Single stage heat output and no
room temperature control
No
In standby mode elSB 0.48 W Two or more manual stages no tem-
perature control
No
With mechanical thermostat room temperature control
No
With electronic room temperature control
No
Electronic room temperature con­trol plus day timer
No
Electronic room temperature con­trol plus week timer
Yes
Other control options No
Room temperature control with presence detection
No
Room temperature control with open window detection
No
With distance control option No
With adaptive start control Yes
With working time limitation No
With black bulb sensor No
Contact details Focal Point Fires, Avon Trading Park, Christchurch Dorset, BH23 2BT