Superior Fireplaces WRT3538WS, WRT3543WS, WRT3538WH, WRT4038IH, WRT4043IS Installation And Operation Instruction Manual

...
Page 1
USC
P/N 900855-00 Rev. B 02/2018
P900855-00
Installation and Operation Instructions
Indoor Wood-burning Fireplace
Ce manuel est disponible en francais, simplement en faire la demande. Numéro de la pièce 900855-01.
®
REPORT NO. F17-136
WRT3538WS WRT3538WH WRT3543WS WRT3543WH
Models
WRT4038IS WRT4038IH WRT4043IS WRT4043IH
SAVE THIS BOOK
This book is valuable. In addition to instructing you on how to install and maintain your appliance, it also contains information that will enable you to obtain replacement parts or accessory items when needed. Keep it with your other important papers.
INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.
Installateur : Laissez cette notice avec l’appareil. Consommateur : Conservez cette notice pour consultation ultérieure.
This wood-burning fireplace complies with UL127 CAN/ULC-S610-M87 standard as a FACTORY BUILT FIREPLACE.
This fireplace is approved for use as a wood-burning fireplace or for use with a vented gas log approved to ANSI Z21.60 or Z21.84 standards or for use with a vent-free gas log heater approved to ANSI Z21.11.2 standard
FOR CANADA: The authority having jurisdiction (such as the municipal building department, fire department, etc.) should be contacted before installation to determine the need to obtain a permit.
Ce foyer au bois est conforme aux UL 127 CAN/ULC­S610-M87 norme comme une USINE CONSTRUITE CHEMINÉE.
.
POUR LE CANADA: L’autorité compétente (comme le service municipal du bâtiment, les pompiers, etc.) doit être contacté avant l’installation afin de déterminer la nécessité d’obtenir un permis.
This installation manual will enable you to obtain a safe, efficient and dependable installation of your fireplace system. Please read and understand these instructions before beginning your installation.
Do not alter or modify the fireplace or its components under any circumstances. Any modification or alteration of the fireplace system, including but not limited to the fireplace, chimney components and accessories, may void the warranty, listings and approvals of this system and could result in an unsafe and potentially dangerous installation.
IMPORTANT! TO ASSURE PROPER ALIGNMENT OF GLASS DOORS: INSTALL THIS FIREPLACE IN A SQUARE AND PLUMB CONDITION, USING SHIMS AS NECESSARY AT SIDES AND/OR BOTTOM.
NOTE: DIAGRAMS AND ILLUSTRATIONS THROUGHOUT THE MANUAL ARE NOT TO SCALE.
Page 2
Thank you for your purchase. We appreciate your business!
Please carefully read and follow all instructions in this manual. Pay special attention to all warnings and safety information.
Following these safety, care, and operation instructions will help ensure many years of dependable and enjoyable service from your fireplace.
Please read and understand these instructions before installing or operating.
SAFETY
TABLE OF CONTENTS
Safety .............................................................................................2
Draft Smoke Guidelines & Troubleshooting....................................4
Specifications .................................................................................6
Fireplace Installation ......................................................................7
Venting Installation ......................................................................10
Refractory Panels Installation ......................................................17
Masonry Brick Panels Installation ................................................18
Optional Gas Line Installation ......................................................19
Glass Door Installation .................................................................20
Operation and Maintenance Guidelines ........................................21
Important Notices - Canada .........................................................23
Technical Service .........................................................................23
Replacement Parts .......................................................................23
Parts ............................................................................................24
Accessories ..................................................................................28
Warranty ......................................................................................31
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual for correct installation and operational procedures. For assis­tance or additional information consult a qualified installer, service agency or the gas supplier.
IMPORTANT: Check local codes before installing this fireplace.
Before beginning the installation of the fireplace, read these instruc­tions through completely.
• This INNOVATIVE HEARTH PRODUCTS, LLC (IHP) fireplace and its components are safe when installed according to this installa­tion manual. Unless you use IHP components, which have been designed and tested for the fireplace system, you may cause a fire hazard.
• The IHP warranty will be voided by and IHP disclaims any re­sponsibility for the following actions.
a. Modification of the fireplace, components, doors, air inlet
system and damper control.
b. Use of any component part not manufactured or approved by
IHP in combination with an IHP fireplace system. Proper installation is the most important step in ensuring safe and continuous operation of the fireplace. Consult the local building codes as to the particular requirements concerned with the installation of all factory built fireplaces.
WARNING: Do not install a fireplace insert in this box unless the manufacturer's instructions with the insert specifically state this fireplace has been tested for use with this insert.
FOR YOUR SAFETY
• Do not store or use gasoline or any other flammable vapors or liquids in the vicinity of this or any other appliance.
• Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.
• Do not place clothing or other flammable materials on or near the appliance.
• Never leave children unattended when a fire is burning in the fireplace.
WARNING: Use solid wood or processed solid fuel firelogs only. When processed wood fuel fire logs are used, do not poke or stir the logs while they are burning. Use only fire logs that have been evaluated for the ap­plication in fireplace and refer to fire log warnings and caution markings on packaging prior to use.
This fireplace is not intended to be used as a substitute for a furnace to heat an entire home. Use for supple­mental heat only.
Overfiring of a fireplace is a condition where exces­sive temperatures are reached, beyond the design capabilities of the appliance. The damage that occurs from overfiring is not covered under the manufacturer’s limited warranty.
SuperiorFireplaces.us.com 900855-00_B2
Page 3
SAFETY Continued
WARNING: CONTINUED OVERFIRING CAN PER­MANENTLY DAMAGE YOUR FIREPLACE SYSTEM. SOME EXAMPLES OF CONDITIONS THAT COULD CAUSE OVERFIRING ARE:
• BURNING QUANTITIES OF SCRAP LUMBER, PINE BRANCH­ES, PAPER OR CARDBOARD BOXES WHICH EXCEED THE VOLUME OF THE NORMAL LOG FIRE.
• BURNING TRASH, CHEMICALS OR CHEMICALLY TREATED COMBUSTIBLES.
Disposal of Ashes Ashes should be placed in a metal container with a tight-
fitting lid. The closed container of ashes should be placed on a noncombustible floor or on the ground, well away from all combustible materials, pending final disposal. If the ashes are disposed of by burial in soil or otherwise locally dispersed, they should be retained in the closed container until all cinders have thoroughly cooled.
WHEN USING THE DECORATIVE APPLIANCE, THE FIREPLACE DAMPER MUST BE SET IN THE FULLY OPEN POSITION.
Never use gasoline, gasoline-type lantern fuel, kero­sene, charcoal lighter fluid, or similar liquids to start or ’freshen up’ a fire in this fireplace. Keep all such liquids well away from the fireplace while it is in use.
WARNING: BURNING IMPROPER FUEL (I.E. CHAR­COAL) CAN RESULT IN CARBON MONOXIDE POISON­ING, WHICH MAY LEAD TO DEATH!
Carbon Monoxide Poisoning – Early signs of carbon monoxide poisoning resemble the flu with headaches, dizziness, or nausea. If you have these signs, get fresh air at once! Have the appliance inspected by a qualified service technician. Some people are more af­fected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.
Ventilation Requirements - Provide adequate air for combustion. The fresh air requirements of this ap­pliance must be met within the space where it will be installed.
Smoke Detectors - Since there are always several potential sources of fire in any home, we recommend installing smoke detectors. If possible, install the smoke detector in a hallway adjacent to the room (to reduce the possibility of occasional false activation from the heat produced by the appliance). If your local code requires a smoke detector be installed within the same room, you must follow the requirements of your local code. Check with your local building department for requirements in your area.
Use SOLID WOOD only for fuel. It is best to use dry and well seasoned hardwood. Softwoods tend to burn very quickly. DO NOT use treated wood, charcoal, coal, trash, driftwood or woods that have been dipped in tar, pitch, pine tar, creosote, etc. Wood products made with synthetic binders, such as plywood, produce ab­normally high temperatures and sputtering, smoking fires. When burning artificial logs, please read and follow the instructions provided by the manufacturer.
Never burn treated construction lumber or scraps. These woods burn excessively hot and may contain chemicals used to treat insects and fungus. When burned, these chemicals can pose a significant hazard.
IMPORTANT: See page 4 for additional information regarding draft requirements, smoking causes and troubleshooting.
Creosote – Formation and Need for Removal
When wood is burned slowly, it produces tar and other organic vapors, which combine with expelled mois­ture to form creosote. The creosote vapors condense in the relatively cool chimney flue of a slow-burning fire. As a result, creosote residue accumulates on the flue lining. When ignited this creosote makes an extremely hot fire.
The chimney shall be inspected at least twice a year during the heating season to determine when a creosote buildup has occurred. When creosote has accumulated (1/8" [3 mm] or more) it shall be removed to reduce the risk of a chimney fire.
WARNING: Children and adults should be alerted to the hazards of high surface temperatures and to stay away to avoid burns or clothing ignition. Young children should be carefully supervised when in the same room as fireplace.
SuperiorFireplaces.us.com900855-00_B 3
Page 4
DRAFT SMOKE GUIDELINES AND TROUBLESHOOTING
Draft Requirements
Your wood-burning appliance is dependent upon a properly func­tioning chimney for optimum performance. It is important to match the wood-burning appliance to the chimney. The chimney has two functions:
1. It draws combustion air into the appliance (without air, no fuel will burn) and
2. It exhausts combustion by-products. Your new appliance is what is known as a “natural draft” appliance.
The appliance depends solely on the natural draft of the chimney system to draw combustion air into the unit. Draft is the force that moves air from the appliance up into the chimney. The amount of draft in your chimney depends on the length of the chimney, local geography, nearby obstructions and other factors. Too much draft may cause excessive temperatures in the appliance (overfiring). Slow or inadequate draft equals poor combustion and possible smoking problems. The following are some conditions that may contribute to poor chimney draft:
1. A chimney too large for your appliance.
2. A chimney with not enough height to produce adequate draft.
3. A chimney with excessive height (this may allow exhaust to cool too much before exiting, which will stall the rate the exhaust exits).
4. Offsets in the venting system are too restrictive (see Chimney Guidelines).
Inadequate draft will cause the appliance to leak smoke into the room through the wood-burning appliance and the chimney connector joints. Excessive draft may cause an uncontrollable burn or a glowing red appliance or chimney part. Overfiring Damage - If the appliance or chimney connector glows, you are overfiring. Other symptoms may include: Cracking, warping or burning out of components, plated accessories may turn color, appliance glass may develop a haze, which will not come off with cleaning.
Overfiring of a appliance is a condition where excessive tempera­tures are reached, beyond the design capabilities of the appliance. The damage that occurs from overfiring is not covered under the manufacturer’s limited warranty.
Also see Troubleshooting on Page 5.
WARNING
Neither the manufacturer nor the seller warrants “smoke free” operation nor are we responsible for inadequate system draft caused by mechanical systems, general construction conditions, inadequate chimney heights, adverse wind conditions and/or unusual environmental factors or conditions beyond our control.
Selecting the Proper Venting System
The appliance is merely one component of a larger system. The other equally important component is the venting system. This is necessary for achieving the required flow of combustion air to the fire chamber and for safely removing unwanted combustion by products from the appliance.
If the venting system’s design does not promote these ends, the system may not function properly. Poorly functioning venting systems may create performance problems as well as be a safety hazard. A draft
test should read greater than .04’ W.C. (inches water column) and less than .08” W.C. As per NFPA-211 standard, the installer must
take into account all variables within the installation and install the appliance in such a manner that satisfies the draft requirements of the appliance. See Chimney Guidelines to assist you in selecting the proper venting system for your installation.
American National Standards Institute ANSI/NFPA 211, Standard for Chimneys, Fireplaces, Vents, and Solid Fuel-Burning Appli­ances - See Draft Section: A chimney or vent shall be so designed
and constructed to develop a flow sufficient to completely remove all flue and vent gases to the outside atmosphere. The venting system shall satisfy the draft requirements of the connected appliance in accordance with the manufacturer’s instructions.
Chimney Guidelines:
• Most wood-burning appliances requires approximately 12 feet minimum of “effective draw” provided by the venting system. As a rule of thumb, every 90 degree total direction change in the venting will result in a loss of approximately 5 feet of “effective draw.” Example: If two 45 degree offsets are used, subtract 5 feet from the actual vertical vent height to determine your “effective draw.” In this case if you had 14 feet of vertical vent, the effective draw would only be approximately 9 feet (14 ft. - 5 ft. = 9 ft.), therefore it may be necessary to add additional height to the venting system.
• Do not install an offset within the first two feet above the flue outlet on the appliance.
• In well insulated and weather tight homes, it may be difficult to establish a good draft up your chimney. The poor draft is caused by a shortage of air in the house. In this situation an Outside Air Kit may need to be installed (See Negative Pressure Warning be­low and Outside Combustion Air in the Installation and Operation manual).
Negative Pressure Warning
These appliances are not designed to be operated in a negative pressure. In very airtight homes with large kitchen exhaust fans, furnace cold air returns, fresh air exchange systems and any other air system in close proximity to the heating appliance may create a negative pressure in the same room as the heating appliance. This can create dangerous back drafting of the appliance and chimney joints, drawing combustion by-products into the home. Be sure your home has adequate makeup air to eliminate negative pressures caused by the above-mentioned sources. Outside air connected to the appliance probably will not resolve such a problem as the appliance is not the source of negative pressure. IHP accepts no liability for damages resulting from negative pressures described here.
Ventilation Requirements - Provide adequate air for combustion. The fresh air requirements of this appliance must be met within the space where it will be installed. Ventilation is essential when using a solid-fuel-burning appliance. In well insulated and weather tight homes, it may be difficult to establish a good draft up the chimney (caused by a shortage of air in the home). The lack of air is caused by many common household appliances which exhaust air from the home (such as a furnace, heat pump, air conditioner, clothes dryer, exhaust fans, fireplaces, and other fuel burning appliances). Also, the combustion process of this appliance uses oxygen from inside the dwelling. If the available fresh air delivery in the dwelling is insufficient to support the demands of these appliances, problems can result (i.e. excessive negative pressure can develop in the dwelling which will affect the rate at which this appliance can draft thus resulting in performance problems or smoking. To correct this problem it may help to open a window (preferably on the windward side of the house) or install an outside air kit.
SuperiorFireplaces.us.com 900855-00_B4
Page 5
DRAFT SMOKE GUIDELINES AND TROUBLESHOOTING Continued
Smoking – Causes And Troubleshooting
To reduce the likelihood of smoking when opening the door, open the combustion air control or damper before opening the door. Your appliance has been designed and tested to provide smoke free operation. Occasionally, there may be a small amount of smoking upon lighting the fire, until the chimney heats up but this should not continue. If the appliance continues to smoke it is probably for one of the following reasons:
A. Negative pressure in the house -
As the fire burns, air goes up the chimney. This air must be
replaced through leakage into the house or through the outside air duct. When operating the appliance, open a nearby window temporarily to check if there is adequate replacement air supply.
B. Blowers operating (e.g.: range hood) - These blowers draw air
out of the house and may actually cause a negative pressure in the house. Turn off all blowers and open a nearby window to determine if this is the cause of the problem.
C. Wet wood - Wet or tarred wood will smoulder and smoke instead
of burning properly.
Your dealer can help you determine if you
have properly seasoned wood for burning.
D. Dirty or blocked chimney - Check to make sure the chimney is
clear and clean.
If dirty call a certified chimney sweep or use a
properly sized chimney brush to clean.
E. Chimney not long enough - Refer to page 7 for minimum and
maximum chimney height Requirements. The chimney must extend at least three (3) feet (915 mm) above its point of contact with the roof and at least two (2) feet (610 mm) higher than any roof or wall within ten (10) feet (3 m) of it. Additional height will increase draft and will decrease the tendency to smoke.
F. Poor chimney draft - With no fire, there should be sufficient draft
to exhaust cigarette smoke introduced under the baffle or flue baffle. Chimneys installed against an outside wall without protection may generate back draft problems which will cause start-up problems. To prevent this, open a nearby window, roll up a piece of paper and light it. Then, hold it in the upper part of the firebox to warm up the chimney. Wait until the draft is sufficient, then start the fire.
Locating The Appliance
The best location to install your appliance is determined by considering the location of windows, doors, and the traffic flow in the room where the appliance is located, allowing space in front of the unit for the hearth extension and the mantel, and taking into consideration the location of the hot air ducts (some models), outside air kit and chimney. If possible, you should choose a location where the chimney will pass through the house without cutting floor or roof joists.
When selecting the location, the chimney outlet position and the direction of the wind are important factor affecting the chimney per­formance. To allow a maximum draft and to reduce wind turbulence, the chimney must:
• Penetrate the highest part of the roof.
• Be installed as far as possible of roof offsets, trees or any other obstructions that may cause wind turbulence and back drafts in the chimney.
• The least amount of offsets (elbows) possible. NOTE: A maximum of 2 offsets is allowed.
Location Recommended
Marginal Location
Wind Direction
Tree
Location
Recommended
Outside Air Intake Facing the Wind
Figure 1
Not
Location Not Recommended
Prohibited Fuels
These appliances are designed to burn natural well-seasoned wood. The wood fuel should be air dried seasoned hardwoods, as compared to softwoods or to green or freshly cut hardwoods. Burning artificial logs, in some model appliances is allowed (see Installation and Op­eration manual); please read and follow the instructions provided by the manufacturer. DO NOT BURN:
• Garbage;
• Lawn clippings or yard waste;
• Materials containing rubber, including tires;
• Materials containing plastic;
• Waste petroleum products, paints or paint thinners, or asphalt products;
• Materials containing asbestos;
• Construction or demolition debris;
• Railroad ties or pres­sure-treated wood; woods that have been dipped in tar, pitch, pine tar, creosote, etc.
• Manure or animal remains;
• Salt water driftwood or other previously salt water saturated materials;
• Unseasoned wood;
• Christmas tree branches;
• Paper products, colored paper, cardboard, plywood, or particleboard;
• Gasoline;
• Naphtha;
• Engine Oil;
• Flammable Liquids;
• Solvents;
• Grease; or
• Charcoal or Coal
NOTE: The use of a firewood moisture meter is recommended to ensure the firewood contains less than 20% moisture.
Seasoning Guide
Softwoods - 6 months to 18 months Hardwoods - 12 months to 24 months
Logs that are 5” diameter across or larger should be split in half, three pieces if over 8 inches, and four pieces when over a foot across. If a tree has been dead for 2 - 4 years it still needs to be cut, split, and seasoned for 6 to 24 months depending on the wood.
Standard
8 Ft.
8'
(2.4M)
Cord of Wood
4 Ft.
4'
(1.2M)
4 Ft. (1.2M)
Figure 2
4'
SuperiorFireplaces.us.com900855-00_B 5
Page 6
SPECIFICATIONS
MODEL CATALOG NO.
WRT3538WS F3412 WRT3538WH F3413 WRT4038IS F3414 WRT4038IH F3415 WRT3543WS F3416 WRT3543WH F3417 WRT4043IS F3418 WRT4043IH F3419
11-1/2"
(292 mm)
44-1/8"
(1121 mm)
24-5/8"
(626 mm)
8"
(204 mm)
1" (26 mm) CHIMNEY AIRSPACE CLEARANCE TO COMBUSTIBLE MATERIAL
38 = 50" (1270 mm)
43 = 54-3/4" (1391 mm)
38 = 38" (966 mm)
43 = 42-3/4" (1086 mm)
38 = 48" (1219 mm)
43 = 52-3/4" (1416 mm)
1" (26 mm)
AIR SPACE
BACK AND SIDES
OUTSIDE AIR
GAS LINE
KNOCKOUT
0" (0 mm)
TO BOTTOM
(1289 mm)
49-7/8"
(1267 mm)
50-3/4"
25-3/4"
(654 mm)
5" (127 mm)
12" (305 mm)
EACH SIDE
14-1/8"
(359 mm)
NO COMBUSTIBLE MATERIAL ON FACE
COMBUSTIBLE WALL BOARD
MINIMUM 12" (305 mm)
TO PERPENDICULAR
SIDEWALL
HEARTH EXTENSION 62" X 20" (1575 mm x 508 mm) 38" MODEL 67" X 20" (1702 mm x 508 mm) 43" MODEL
38 = 26-3/8" (670 mm) 43 = 31-1/8" (791 mm)
15" (381 mm)
12-3/8"
(315 mm)
38 = 24" (610 mm)
43 = 26-3/8" (670 mm)
TOP VIEW
5/8" (16 mm)
FRONT
11-5/8" (296 mm)
LEFT SIDE RIGHT SIDE
13-1/8"
(334 mm)
15-1/8"
(385 mm)
9-1/4"
(235 mm)
Figure 3 - Fireplace Specifications
SuperiorFireplaces.us.com 900855-00_B6
Page 7
FIREPLACE INSTALLATION
SELECTING LOCATION
To determine the safest and most efficient location for the fireplace, you must take into consideration the following guidelines:
1. The location must allow for proper clearances (see Figures 4 thru
7).
2. Consider a location where fireplace will not be affected by drafts, air conditioning ducts, windows or doors.
3. A location that avoids cutting of joists or roof rafters will make installation easier.
4. An outside air kit is available with this fireplace (see Optional Outside Air Kit on page 10).
MINIMUM CLEARANCE TO COMBUSTIBLES
Back and sides of fireplace 1" (26 mm) min. Ceiling 42" (1067 mm) min. Front of fireplace 48" (1220 mm) min. Floor** 0" (0 mm) min. Perpendicular wall to opening 12" (305 mm) min.
Top spacers 0" (0 mm) min. Mantel clearances Chimney outer pipe surface 1" (26 mm) min.
* Not required at nailing flanges ** See step 2 of Framing
see Mantels, page 9
WARNING: Do not pack required air spaces with
insulation or other materials.
Minimum/Maximum Chimney Height for Residential Installation
Minimum height of chimney, measured from base of fireplace to flue gas outlet of termination, is 16 feet for straight flue or a flue with one elbow set. Maximum distance between elbows is 6 feet. For systems with two elbow sets, minimum height is 22 feet. Maximum height of any system is 50 feet. This measurement includes fireplace, chimney sections and height of termination assembly at level of the flue gas outlet (see Figure 17, page 13).
FRAMING
1. Frame opening for fireplace using dimensions shown in Figures 4 and 5.
2. If fireplace is to be installed directly on carpeting, tile or any combustible material other than wood flooring, fireplace must be installed upon a metal or wood panel extending full width and depth of fireplace.
3. Set fireplace directly in front of this opening and slide unit back until nailing flanges touch side framing.
4. Check level of the fireplace and shim with sheet metal if necessary.
5. Before securing fireplace to prepared framing, ember protector (provided) must be placed between hearth extension (not sup­plied) and under bottom front edge of fireplace to protect against glowing embers falling through. If fireplace is to be installed on a raised platform, a Z-type ember protector (not supplied) must be fabricated to fit your required platform height. Ember protector should extend under fireplace a minimum of 1 1/2". Ember protector should be made of galvanized sheet metal (28 gauge minimum to prevent corrosion.
6. Using screws or nails, secure fireplace to framing through flanges located on sides of fireplace.
SuperiorFireplaces.us.com900855-00_B 7
Page 8
FIREPLACE INSTALLATION Continued
Back Wall of Chase/Enclosure
FRAMING SPECIFICATIONS
A
B
C
D
E
F
G
J
(1251 mm)
(1293 mm)
(667 mm)
(334 mm)
(1962 mm)
(981 mm)
(667 mm)
(279 mm)
Fireplace Opening Width
38 43
49-1/4"
(1372 mm)
50-7/8"
50-7/8"
(1293 mm)
26-1/4"
(787 mm)
13-1/8"
15-1/2"
(394 mm)
77-1/4"
(2083 mm)
38-5/8"
(1041 mm)
26-1/4"
26-1/4"
(667 mm)
11"
(279 mm)
54"
31"
82
41"
11"
AK4 Combustion Air Kit
"
AK4 Combustion Air Kit
K
Back Wall of Chase/Enclosure Including Finising Materials if any
A
Inside Chase
Rough Framing Face (Unfinished Shown)
Figure 5 - Inside Chase
Including Finishing Materials if any
D
G
F
K
Note: All framing dimensions calculated for 1/2" dry wall at the fireplace face. If sheathing the chase or finishing with other thickness materials, calculations will need to be made.
54-5/8"
(1388 mm)
58"
(1473 mm)
Header
B
Figure 6 - Corner Installation
AK-4 Combustion Air Kit
J
Rough Framing Face (Unfinished Shown)
C
A E
Corner Installation
Back Wall of Chase/Enclosure
Including Finishing Materials
A
Rough
Framing Face
(Unfinished Shown)
if any
G
Outside Chase
A
Figure 4 - Fireplace Framing
Figure 7 - Outside Chase
SuperiorFireplaces.us.com 900855-00_B8
Page 9
FIREPLACE INSTALLATION Continued
Combustible Mantel
HEARTH EXTENSION
A hearth extension projecting a minimum of 20" in front of and a minimum of 12" beyond each side of fireplace opening is required to protect combustible floor construction in front of fireplace. Fabri­cate a hearth extension using a material which meets the following specifications: a layer of noncombustible, inorganic material having a thermal conductivity of k=0.84 BTU IN/FT, HR. F (or less) at 1" thick. For example, if the material selected has a k factor of 0.25, such as glass fiber, the following formula would apply:
0.25 x 1.0" = 0.30" thickness required
0.84 Thermal conductivity "k" of materials can be obtained from manufac-
turer or supplier of noncombustible material. If hearth extension is to be covered, use noncombustible material such as tile, slate, brick, concrete, metal, glass, marble, stone, etc. Provide a means to prevent hearth extension from shifting and seal gap between fireplace frame and hearth extension with a noncombustible material (see Figure 8).
WARNING: Hearth extension is to be installed only
as shown in Figure 8.
Seal Gap
Fireplace Front
Ember Protector
MANTELS
A mantel may be installed if desired (see Figure 9). Woodwork such as wood trims, mantels or any other combustible material projecting from front face must not be placed within 12" of the fireplace (NFPA 211, Section - Clearance from Combustible Material).
Mantels or any other combustible material also may come up to side edge of black metal face of fireplace as long as projections from front face fall within limit shown in Figure 9.
Finished Wall
Header
12"
(305 mm)
Max.
Spacer
12"
*
(305 mm)
Min.
Noncombustible Wall Covering
Fireplace Opening
* A 1-1/2" Projection Is Permitted Between The Face Top And Mantle
Fireplace Front Raised Hearth
Ember Protector
Fireplace Front Elevated
Ember Protector
Figure 8 - Hearth Extension
Seal Gap
Hearth
Extension
Combustible Materials Allowed in Shaded Area
4-17/32"
(115 mm)
30˚
12" (305 mm)
Minimum Distance
to Protected Side Wall
Figure 9 - Mantel Clearances to Combustible Materials
1/2"
(13 mm)
SuperiorFireplaces.us.com900855-00_B 9
Page 10
VENTING INSTALLATION
OPTIONAL OUTSIDE AIR KIT (MODEL AK4/AK4F)
The installation of an outside air kit should be performed during the rough framing of the fireplace due to the nature of it's location. Outside combustion air is accessed through a vented crawl space (AK4F) or through a sidewall (AK4).See page 21 for instructions of operating air kit.
CAUTION: Combustion air inlet ducts shall not
terminate in attic space.
The maximum height for the air vent can not exceed 3 feet below the flue gas outlet of the termination.
Secure to Collars with Metal Tape, Screws or Straps (Min. of 1/4" x 20" in size)
Vent Hood Required for Wall Installation
Vented Crawl Space (Check Local Codes Before Installing in a Vented Crawl Space)
Air Inlet Location Must Allow For Bushes or Snow
Air Inlet Eyebrow
Figure 10 - Outside Air Kit
LINEAL GAIN
PART NO. DESCRIPTION GAIN
Fireplace 49 3/4" (1264 mm)
12-12DM
12-12HT
18-12DM
18-12HT
24-12DM
24-12HT
36-12DM
36-12HT
48-12DM
48-12HT RLT-12D
RLT-12HT
STL-12D
* The lineal gain for the terminations is measured to the flue gas outlet height.
15" Galvanized Outer Pipe
12 3/8" Stainless Inner Pipe
Pipe Section 10 5/8" (270 mm)
Pipe Section 16 5/8" (423 mm)
Pipe Section 23 5/8" (600 mm)
Pipe Section 34 5/8" (880 mm)
Pipe Section 46 5/8" (1185 mm)
Round Termina-
tion
Square Chase-
Top with Slip
Section
* (197 mm)
7 3/4"
7
" (178 mm)
15"* (381 mm)
Hemmed End
to
CHIMNEY PIPE
WARNING: Label part number 900599-01 must be applied by the installer to all chimney pipe sections but is not required on sections that will be visible after the installation is complete. Label must wrap around the circumference of the pipe. See accessories, page 29 for Kit F2659.
The IHP chimney system consists of 12", 18", 24", 36" and 48" snap­lock, double-wall pipe segments, planned for maximum adaptability to individual site requirements. Actual lengths gained after fitting overlaps must be taken into consideration (lineal gain) and are given in the lineal gain chart (see Figure 11). Lineal Gain is the actual mea­surable length of a part after two or more parts are connected. For Canada, use chimney parts designated "HT".
WARNING: The opening in the collar around the chimney at the top of the fireplace must not be ob­structed. Never use blown insulation to fill the chimney enclosure.
Figure 11 - Lineal Gain
ASSEMBLY AND INSTALLATION OF DOUBLE WALL CHIMNEY SYSTEM
Each double wall chimney section consists of a galvanized outer pipe, a stainless steel inner flue pipe and a wire spacer. The pipe sections must be assembled independently as the chimney is installed. When connect­ing chimney directly to the fireplace, the inner flue pipe section must be installed first with the lanced side up. The outer pipe section can then be installed over the flue pipe section with the hemmed end up. Press down on each pipe section until the lances securely engage the hem on the fireplace starter. The wire will assure the proper spacing between the inner and outer pipe sections.
Continue to assemble chimney sections as outlined above, making sure that both the inner and outer pipe sections are locked together. When installing double wall snap-lock chimney together, it is impor­tant to assure the joint between the chimney sections is locked. Check by pulling chimney upward after locking. The chimney will not come apart if properly locked. It is not necessary to add screws to keep the chimney together (exception, see Figure 12, page 11).
The height of a vertical chimney pipe supported ONLY by the fire- place, must not exceed 20 feet. Chimney heights above 20 feet must be supported.
SuperiorFireplaces.us.com 900855-00_B10
Page 11
VENTING INSTALLATION Continued
OFFSET
A B 12" 18" 24" 36" 48"
4 3/8" 16 3/8" 9 3/4" 25 1/2"
12 3/4" 30 3/4"
15" 34 3/4"
18" 40" 21 1/4" 46 1/4" 23 3/4" 49 1/4" 27 3/4" 56 3/4"
30" 60 3/4"
33" 66"
36" 71" 38 1/4" 75" 41 1/4" 80 1/4"
45" 86 3/4" 46 3/4" 89 1/2"
51" 97" 53 1/4" 101" 56 1/4" 106 1/4" 59 1/4" 111 1/2" 61 3/4" 115 1/2" 64 3/4" 120 3/4" 68 1/4" 127"
70" 130" 74 1/4" 137 1/2"
RISE CHIMNEY LENGTH
ELBOW SET ONLY
1
1
1
1 1
1 1
1 1
1 1
1 1
1 1 1
1 2
1 1 1
1 2
1 2
1 1 2 1 2 1
1 2 1
1
2
1 1
2 1
4
USING ELBOW OFFSETS (30E-12DM)
1.
To achieve desired offset, you may install combinations of 12", 18", 24", 36" and 48" length of double wall pipe (see offset chart and Figure 12).
2.
Chimney weight above offset rests on return elbow. Straps must be securely nailed to rafters or joists (see Figure 13, details A and B).
3. Maximum length of pipe between supports (return elbow or
1
2
12S-12DM) is 6' of angle run. Maximum of two 6' angle run sections per chimney system (see Figure 14, page 12).
4. All pipe connections between the offset and return must be secured with two screws on the outer pipe only (see Figure
12). Do not penetrate the inner stainless.
See Detail A
2" (51 mm)
Min.
Straps
Straps
Detail B
Angle Firestop
See Detail B
OFFSET CHART (22-50 FT. SYSTEM HEIGHT)
Screws
Straps
Detail A
Return Elbow
Figure 13 - Ceiling Support Pipe 12S-12DM
Straps
CAUTION: THE STRUCTURAL INTEGRITY OF THE
B
MANUFACTURED HOME FLOOR, WALL, AND CEILING/ ROOF MUST BE MAINTAINED.
WARNING: DO NOT INSTALL IN SLEEPING ROOM
OF MOBILE HOMES.
A
Figure 12 - Elbow Offset
SuperiorFireplaces.us.com900855-00_B 11
Page 12
VENTING INSTALLATION Continued
Return Elbow
Offset Elbow
Return Elbow
Offset Elbow
6' (1.88 m)
Max.
6' (1.88 m)
Max.
Offset Elbow
Offset Elbow
Return Elbow
A B C
Figure 14 - Typical Offset Terminations
FIRESTOP SPACERS (1100EFS-10DM)
Firestop spacers are required at each point where the chimney penetrates a floor space. Their purpose is to establish and maintain the required clearance between the chimney and the combustible materials. When the pipe passes through a framed opening into a living space above, the firestop must be placed onto the ceiling from below as shown in Figure 15.
They also provide complete separation from one floor space to another or attic space as required by most codes. When the double wall pipe passes through a framed opening into an attic space, the firestop must be placed into an attic floor as shown in Figure 16.
Return
Return Elbow
6' (1.88 m)
Max.
6' (1.88 m)
Max.
6' (1.88 m)
6' (1.88 m)
Max.
Max.
Elbow
Ceiling
Support Pipe
12S-12DM
Offset Elbow
IMPORTANT NOTICE When penetrating a ceiling into an attic, a firestop thimble (FST10) is required to avoid intrusion by insu­lation and recommended to negotiate a joist.
Firestop Thimble FST10
Existing Ceiling Frame
Firestop Spacer
Screws or Staples (Min. of 8)
Figure 15 - Firestop Spacer with Living Space Above Ceiling
Firestop Spacer
Figure 16 - Firestop Spacer with Attic Space Above Ceiling
Screws or Staples (Min. of 8)
Existing Ceiling Frame
Figure 16a - Firestop Thimble
PENETRATING ROOF
To maintain a 1" clearance to the pipe on a roof with a pitch, a rect­angular opening must be cut.
1. Determine center point through which pipe will penetrate roof.
2. Determine center point of roof. Pitch is distance the roof drops over a given span, usually 12". A 6/12 pitch means that roof drops 6" for each 12" measured horizontally down from roof rafters.
3. Use roof opening chart (Figure 17, page 13) to determine correct opening length and flashing required.
4. Remove shingles around opening measured. Cut out this section.
5. Add next sections of pipe until end penetrates roof line. Check to see that proper clearances are maintained. Extend chimney by adding sections of double wall pipe until pipe is minimum of 30" above highest point of roof cutout. Termination and chimney must extend a minimum of 36" above highest point where it passes through roof.
SuperiorFireplaces.us.com 900855-00_B12
Page 13
VENTING INSTALLATION Continued
17"
(432 mm)
Min.
1" (26 mm)
Min
1" (26 mm)
Min
Pitch Slope Opening "A"
Opening "A"
Used Flashing
Max.
30" (762 mm)
1" (26 mm)
Min
Model No.
Flat 17" (432 mm) V6F-10DM
0-6/12 26.6° 19" (483 mm) V6F-10DM
6/12-12/12 45.0° 24" (610 mm) V12F-10DM
Figure 17 - Roof Opening Measurements
Min.
FLASHING INSTALLATION (V6F-10DM OR V12F-10DM)
Determine the flashing to be used with the roof opening chart. Slide flashing over pipe until base is flat against roof. Replace as many shingles as needed to cover exposed area and flashing base. Secure in position by nailing through shingles (see Figure 18). DO NOT NAIL THROUGH FLASHING CONE.
Installing Flashing on a Metal Roof
When installing the flashing on a metal roof, it is required that putty tape be used between the flashing and the roof. The flashing must be secured to the roof using #8 x 3/4" screws and then sealed with roof coating to prevent leakage through the screw holes. A roof coating must also be applied around the perimeter of the flashing to provide a proper seal.
Storm Collar
Overlap Shingles
Flashing
Top and Sides Only
Cone
Nail Only Outer Perimeter of Flashing
Underlap Shingles at Bottom
Figure 18 - Flashing Installation
Storm Collar Installation (SC2-1)
Place storm collar over pipe and slide down until it is snug against the open edge of the flashing (see Figure 19). Apply waterproof caulk around the perimeter of the collar to provide a proper seal.
Chimney Pipe
Waterproof Caulk
Storm Collar
Flashing
Figure 19 - Storm Collar
SuperiorFireplaces.us.com900855-00_B 13
Page 14
VENTING INSTALLATION Continued
Terminations/Spark Arrestor
The fireplace system must be terminated with the listed round top or chase terminations. In any case, refer to the installation instructions supplied with the termination.
CAUTION: Do not seal openings on the rooftop flashing. Follow the installation instructions provided with the termination being used.
Stainless Inner Flue Pipe
Secure Termination to Outer Pipe with 3 Screws
Overlap Shingles (Top and Sides of Flashing Base)
Figure 20 - Termination
CHASE INSTALLATIONS
Instructions for chase installations are included with the chase style termination chosen. In a multiple chase installation, be sure to provide adequate distance between terminations to prevent smoke spillage from one termination to another. We suggest that terminations be separated at least 24", center to center and stacked at a vertical height difference of 18" (see Figure 21).
Note: If a decorative shroud is to be installed, contact the manufac­turer for specifications.
RLT-12D
Level of Flue Gas Outlet
Waterproof Caulking
Storm Collar
Flashing
Underlap Shingles
10 FOOT RULE
All flue gas outlet chimney terminations must extend a minimum of 3 feet in height above the highest point where it passes through the roof and must be at least 2 feet above the highest point of the roof that is within a horizontal distance of 10 feet (see Figure 22).
10'
(3.05 m)
Level of Flue Gas Outlet
10'
(3.05 m)
2' (0.61 m) Min.
3'
(0.91 m)
Min
2' (0.61 m)
Min.
3'
(0.91 m)
Min
Figure 22 - 10 Foot Rule
SQUARE TOP TERMINATIONS INSTALLATION STL-12D AND STL-12DMP
1. Construct chase as illustrated in Figure 23. Note: The shortest
vertical side must be at least 30" high and minimum inside di­mension must be at least 19" as shown in Figure 23.
2. Add pipe sections to chimney system as outlined in fireplace installation instructions until last piece of chimney is a maximum of 6" below top of chase (see Figure 23).
19"
(483 mm)
30"
(762 mm)
Min.
6" (153 mm) Max.
24" (610 mm)
24" (610 mm)
Figure 21 - Multiple Chase Installation
18" (458 mm)
Min. Typ.
Figure 23 - Constructing Chase
SuperiorFireplaces.us.com 900855-00_B14
Page 15
INSTALLATION Continued
3. Fabricate a flashing having a 16-1/2" diameter hole centered over chimney end with a 2" collar around hole (see Figure 24). Attach noncombustible spacers at each corner and place flash­ing over chase.
4. Secure flashing through sides with 8-penny nails or sheet rock screws.
5. Place galvanized sleeve through hole in flashing and around last section of chimney (see Figure 25).
6. Place termination cap over opening and slip stainless steel inner pipe into stainless steel chimney section. Lower termination as­sembly until cap rests evenly over flashing hole. Secure cap at each corner with sheet metal screws (see Figure 26).
16-1/2" Diameter
2" Collar
As Required
28 Gauge Galvanized Steel
Figure 24 - Constructing Chase Top Flashing
1" Spacer
Termination Cap
Note: Do Not Seal Ventilation Openings
Termination
Sheet Metal Screw
1" Noncombustible Spacer
Chase Top
1" Space
1/4" Screen
Note: Do Not Seal
Chase Facia
Ventilation Openings
Figure 26 - Securing Termination to Chase Top Flashing with Sheet
Metal Screws
ROUND TOP TERMINATIONS INSTALLATION RLT-12D, AND RLT-12HT
1. Construct chase as illustrated in Figure 27. Note: The shortest
vertical side must be at least 30" high and the minimum inside dimension must be at least 19" as shown in Figure 27.
2. Add pipe sections to chimney system as outlined in fireplace installation instructions until the last piece of chimney is a minimum of 6" above chase top (see Figure 27).
3. Fabricate a flashing having a 16-1/2" diameter hole centered over chimney end with a 2" collar around hole (see Figure 28, page 16).
36"
(915 mm)
Min.
Galvanized Sleeve
2" (51 mm) Min.
Figure 25 - Installing Termination Cap
3"
(77 mm)
Min.
Screw
19"
(483 mm) Min.
6" (153 mm) Min.
30"
(762 mm)
Min.
Figure 27 - Constructing Chase
SuperiorFireplaces.us.com900855-00_B 15
Page 16
INSTALLATION Continued
4. Attach noncombustible spacers at each corner and place flashing over chase (see Figure 29). Secure flashing through sides with 8-penny nails or sheet rock screws.
5. Place termination cap over opening. Slip stainless steel inner pipe of termination into inner stainless steel chimney section (see Figure 30). Place galvanized steel over chimney outlet (see Figure 31).
6. Attach storm collar where chimney pierces opening in flash­ing. Caulk where storm collar touches outer chimney pipe (see Figure 31).
16-1/2" Diameter
28 Gauge Galvanized Steel
Figure 28 - Constructing Chase Top Flashing
1" Noncombustible Spacer
2" Collar
As Required
Chase Top
Note: Do Not Seal Ventilation Openings
Caulk
Storm Collar
1" Spacer
Chase Top Flashing
1" Space
"X" Minimum
Double Wall Chimney
"X" Minimum
Figure 31 - Chase Installation
NONCHASE INSTALLATION
1. Slip on proper pitch roof flashing and mount storm collar above it. Caulk top of storm collar where it contacts outer chimney pipe.
2. Mount round top termination and secure it to outer chimney pipe with 3 sheet metal screws.
3"
(77 mm)
Min.
Termination Cap
6" (153 mm)
Min.
Chase
Flashing
Termination Cap
Note: Do Not Seal Ventilation Openings
Figure 29 - Chase Top Flashing
Outer Pipe
Figure 30 - Installing Termination Cap
1/4" Screen
Chase Facia
Termination
Inner Pipe
1" Space
Sheet Metal Screw
Caulk
Inner Pipe of Chimney
Overlap Shingles (Top and Sides)
Figure 32 - Non-Chase Installation
FINISHING FIREPLACE
Combustible materials, such as wallboard, sheet rock, drywall, plywood, etc. may make direct contact with sides and top around the fireplace face. It is important that combustible materials do not overlap the face itself. Brick, glass, tile or other noncombustible materials may overlap the front face provided they do not obstruct essential openings like louvered slots or any other opening. When overlapping with a noncom­bustible facing material, use only noncombustible mortar or adhesive.
Storm Collar
Flashing
Underlap Shingles (Bottom Only)
SuperiorFireplaces.us.com 900855-00_B16
Page 17
REFRACTORY PANEL INSTALLATION
WARNING
LIFTING HAZARD
SINGLE -PERSON LIFT COULD
CAUSE INJURY.
USE ASSISTANCE WHEN MOVING
OR LIFTING.
Fireplace models WRT3538WS, WRT3538WH, WRT4043WS and WRT4043WH, contain a refractory hearth, sides, back, and a metal grate, factory mounted. The refractories are reinforced with steel, but can be broken by improper use. Dropping logs on the bottom refractory and building fires directly against the refractories can cause premature burnout of these components. The refractories may easily be replaced.
If replacing refractories, follow the instructions below.
IMPORTANT: Installation of Refractory panels should be done after the fireplace is placed in a permanent location.
1. Remove grate, screen assemblies and all hardware components out of the firebox (save hardware components for reinstallation).
2. Open the box containing the refractories and identify them.
3. Install rear refractory panel. This panel has a top and bottom. To determine which is the top or bottom, match up the pattern on the rear panel with the left and right sides before installing the rear panel. Align the left and right panels with the rear panel so the grout lines line up. Install the retaining bracket and tighten set screws (Figure 33).
4. Install the right and left refractory panels with the gas line knock­outs oriented down toward the firebox bottom. Install the retaining brackets and tighten set screws (Figure 34).
5. Position grate retaining brackets toward the rear of the bottom refractory (see Figure 34). They should be positioned a distance apart as shown in Figure 33.
6. Install refractory hearth panel, insert the front of the panel tilted then slowly let the rear portion go down. Make sure the front of the hearth is flush with the fireplace and the grate retaining brackets are centered (see Figure 33)
7. Install grate, screen assemblies and all hardware components removed in step 1.
Retaining Bracket
Left Refractory Panel
Bottom Refractory Panel
38 SERIES 12 CENTERS
43 SERIES 14 CENTERS
Figure 33 - Installing Grate Retainers
Rear Refractory Panel
Right
Refractory
Panel
Grate Retainer
Figure 34 - Installing Refractory Panels
WARNING: Risk of fire! Replace grate with IN­NOVATIVE HEARTH PRODUCTS grate only (see Parts, pages 24 and 25). This grate has been designed to keep the operation of your fireplace safe and efficient.
INSTALLING SCREEN
1. Slide round end of screen rod into rings at top of screen. Attach one push-on nut to end of rod before attaching last ring of screen.
2. Insert the round end screen rod into hole on the left and right side of smoke shelf (Figure 35).
3. Mount flat end of screen rod with #10 x 5/8" to center of smoke shelf.
4. Install other screen rod in same manner.
SuperiorFireplaces.us.com900855-00_B 17
Hole for screw to Hold Screen
Rod
Hole for
Screen Rod
Rating Plate
Figure 35 - Installing Fireplace Screen
Page 18
MASONRY BRICK PANEL INSTALLATION
Fireplace models WRT4038IS, WRT4038IH, WRT4043IS and WRT4043IH, contain a masonry brick hearth, sides and back. The masonry brick hearth is factory mounted, the back and sides are strapped to the back and sides of fireplace. These masonry brick pan­els are reinforced with steel, but can be broken by improper use. The masonry brick panels may easily be replaced. Follow the instructions below for installation of sides and rear masonry brick panels or when
replacing entire kit.
IMPORTANT: Installation of masonry brick panels should be done after the fireplace is placed in a permanent location.
Front Cover Plate
Note: Remove grate, screen assemblies and all hardware components out of the box prior to installation.
INSTALLATION
1. Make sure masonry brick hearth panel is centered in the firebox
and flush with the front of the fireplace. Be careful not to pinch your fingers between the panel and firebox (Figure 36). Note: If
replacing entire kit, start with the masonry brick hearth panel, then follow steps below.
2. Install the left and right masonry brick panels, align flush with
front cover plates and secure them with retaining brackets and screws (provided), see Figures 36 and 37.
3. Place the provided grate retainers on the masonry brick hearth
as shown in Figure 37 and refer to Figure 33, page 17 for cor­rect distance.
4. Install the rear masonry brick panel last. Place the rear masonry
brick panel against the back of firebox align flush with left and right masonry brick panels and secure with retaining brackets and screws (provided) see Figure 37.
Note: Install grate, screen assemblies and all hardware components into the firebox following steps in reverse from Refractory Panel Installation, page 17.
Masonry Brick Hearth Panel
Left Masonry Brick Panel
Figure 36 - Hearth Brick Panel
Retaining Bracket
Grate Retainer
Rear Masonry
Brick Panel
Right Masonry
Brick Panel
Figure 37 - Installing Masonry Brick Side and Rear Panels
SuperiorFireplaces.us.com 900855-00_B18
Page 19
OPTIONAL GAS LINE INSTALLATION
Gas line hook up should be done by your supplier or a qualified service person.
Note: Before you proceed, make sure your gas supply is turned off. Use only a 1/2" black iron pipe and appropriate fittings.
1. Remove knockout indentation on refractory or firebrick wall lo­cated above refractory hearth floor. Knockout indentation must be firmly tapped with any solid object such as a 1/2" dowel until it is released. Remove fragmented portions of refractory (see Figure
38).
2. Remove gas line cover plate located on either side of fireplace and pull out insulation from gas line conduit sleeve. Save insulation for reuse. Replace screws.
3. Run a 1/2" black iron gas line into fireplace through the rear at gas line conduit sleeve (if using a raised platform, add height). Provide sufficient gas line into fireplace chamber for fitting connection (see Figure 39).
Note: Secure incoming gas line to wood framing to provide rigidity for
threaded end.
4. Repack insulation around gas line and into sleeve opening. Seal any gaps between gas line and refractory knockout hole with refractory cement or commercial furnace cement, Install the gas appliance or cap-off gas line if desired.
CAUTION: All gas piping and connections must be tested for leaks after the installation is completed. After ensuring that the gas valve is on, apply soap and water solution to all connections and joints. Bubbles forming show a leak. Correct all leaks at once. DO NOT USE AN OPEN FLAME FOR LEAK TESTING AND DO NOT OPERATE ANY APPLIANCE IF A LEAK IS DETECTED. LEAK TESTING SHOULD BE DONE BY A QUALIFIED SERVICE PERSON.
Note: An IHP hood must be installed when using an unvented gas log set (see Accessories on page 29).
WARNING: Do not operate an unvented gas log set in this fireplace with the chimney removed.
Outside of Fireplace
Gas Line Conduit
Insulation
Remove Knockout
Side Firebrick Finished Side
1/2" Dowel
Outside of Fireplace
Incoming 1/2"
Gas Line Conduit
Repack Insulation
A gas line or gas log lighter may be installed for the purpose of installing a vented or vent-free decorative gas appliance incorporating an automatic shutoff device and complying with the Standard for Decorative Gas Ap­pliances for Installation in Vented Fireplaces, ANSI Z21.60 or American Gas Association draft requirements for Gas Fired Log Lighters for Wood­burning Fireplaces, Draft NO. 4 dated August, 1993.
If you install a decorative gas appliance (vented gas log), the deco­rative gas appliance must comply with the Standard for Decorative Gas Appliance for Installation in Solid Fuel Burning Fireplaces, ANS Z21.60 or Z21.84 and shall also be installed in accordance with the National Fuel Gas Code, ANSI 7223NFPA 54 latest edition.
If you wish to install an unvented (vent-free) gas log set, only unvented gas log sets which have been found to comply with the standard for unvented room heaters, ANSI Z21.11.2 are to be installed in this fireplace.
Black Iron Pipe
Seal Opening with Refractory Cement
Figure 39 - Gas Line Installation
Side Firebrick Finished Side
Provide Enough Threaded End for Fitting Connection
WARNING: If the fireplace has been used for wood­burning, the firebox and chimney must be cleaned of soot, creosote and ashes be a qualified chimney cleaner. Creosote will ignite if heavily heated.
WARNING: When using a decorative vented gas log, the damper must be removed or permanently locked in the fully open position and the glass doors must be in the fully open position.
Gas Conduit Cover
Brick with Access Hole
Figure 38 - Gas Line Access
SuperiorFireplaces.us.com900855-00_B 19
Page 20
GLASS DOOR INSTALLATION
WARNING
This kit is to be installed by a qualified service technician or other qualified agency in accordance with the manufacturer's instructions and all codes and requirements of the Authority Having Jurisdiction in the USA or Canada. If these instructions are not followed exactly, a fire or explosion may result, causing property damage, personal injury, or loss of life. The qualified agency performing this work assumes responsibility for this installation.
INSTALLING OPTIONAL GLASS DOOR MODELS 38LBF and 43LBF
Use only the doors that are listed for use with these fireplaces. Use of other non-listed glass door on these fireplaces may constitute a potential fire hazard and is not recommended.
Note: Top door rail, and spring clips are provided with the glass door kit.
1. Using a Phillips screwdriver, remove the three (3) factory installed screws underneath top front face.
2. Position the door rail and secure it with one (1) of the screws removed, start from the middle as shown in Figure 40.
3. Using remaining two (2) screws, secure both the spring clips and the rail for the left and right sides as shown in Figure 40.
4. With bi-fold doors completely folded, insert bottom pivot pin into pivot hole located near bottom corner of front face opening and swing door to vertical position making sure top pins slide into door track. Door is installed when top door pin snaps into spring clip (see Figure 41).
5. Repeat step 4 for remaining door.
If you find doors do not close properly or do not appear level or straight, proceed with section on door adjustment.
Fold Door and Slide Top Pins Into Track
Figure 41 - Installing Bi-Fold Doors
Spring Clip
Insert Pin into Spring Clip
Insert Bottom Pivot Pin into Hole
Pivot Hole
Screw
Door rail
Top Face
DOOR ADJUSTMENT
Remove doors and slightly loosen upper spring clips. Replace doors and fully close them. Use 1/8" shims (any material) to level doors. Once proper setting is achieved, carefully open doors enough so that you can access spring clips with a Phillips screwdriver. Tighten screws. See Figure 42.
Spring Clip
Figure 42 - Adjusting Bi-Fold Doors
Figure 40 - Installing Door Rail
SuperiorFireplaces.us.com 900855-00_B20
Page 21
GLASS DOORS
OPERATION AND MAINTENANCE GUIDELINES
WARNING
HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS UNTIL COOLED. ALLOW CHILDREN TO TOUCH GLASS.
• Fireplaces surfaces get EXTREMELY HOT!
• Install only when fireplace is OFF and COLD.
• The glass on the front of the fireplace reaches EXTREMELY HIGH temperatures and can cause severe burns if touched. Even after the gas is turned off, fireplace surfaces remain extremely hot.
• Keep children away from an operating fireplace. Closely supervise children in any room where a fireplace is operating to prevent contact with glass.
Glass doors are optional with the fireplace. When fireplace is in operation, doors must be fully opened or fully closed position only or a fire hazard may be created (see Figure 43).
A fireplace equipped with glass doors operates much differently than a fireplace with an open front. A fireplace with glass doors has a limited amount of air for combustion.
Excessive heat within the fireplace can result if too large a fire is built or if combustion air gate is not completely open. The following tips should be followed to assure that both the fireplace and glass door retain their beauty and function properly. Both the flue damper and glass doors must be fully opened before starting fire. This will provide sufficient combustion air and maintain safe temperatures in firebox.
IMPORTANT: The glass must be allowed to warm slowly and evenly. The tempered glass will withstand a gradual temperature rise to 550° F, which is more than a normal fire will generate. Such materials as pitch/wax laden logs, very dry mill end lumber and large amounts of paper or cardboard boxes can create an excessively hot fire and should not be burned in this fireplace. Always keep the fire well back from the doors and never allow flames to contact the glass.
NEVER
Doors Fully Closed
Fireplace Front
Doors Fully Opened
Fireplace Front
Figure 43 - Bi-Fold Glass Doors
Cleaning Glass
Clean glass with any commercial glass cleaner or soap and water. Do not use any abrasive material to clean glass. Do not clean glass with any cool water if glass is still hot from the fire and smoke.
WARNING: Fireplaces equipped with glass doors should be operated only with doors fully opened or doors fully closed. Doors, if left partly open, may draw gas and flame out of the fireplace opening creating risks of both fire and smoke.
WARNING: Do not slam or strike doors. Damage can result in a hazardous condition.
WARNING: Discontinue use of the appliance imme­diately if doors are damaged and contact a qualified installer for repair. Only doors certified with the ap­pliance shall be used.
SuperiorFireplaces.us.com900855-00_B 21
Page 22
OPERATION AND MAINTENANCE GUIDELINES Continuation
STARTING A FIRE
1. To properly start a fire in a the fireplace, first check the operation of the flue damper (see “DAMPER CONTROL” and Figure 44, below).
2. To prevent smoke at startup, close all windows near the fireplace when first lighting a fire. The closed windows may be reopened once a chimney draft is drawn in the fireplace.
3. Center the grate in the firebox on or over the bottom hearth so the fire can breathe properly. Crumble and twist plenty of newspapers UNDER the grate, and criss-cross some small, dry kindling sticks on top of the paper or on the bottom of the grate.
4. Build a pyramid of three split logs (split wood will light more quickly). Arrange the logs to provide plenty of air space between them.
5. Light the paper at both sides of the firebox.
6. Close the screens to prevent the escape of sparks and embers.
7. Close the damper only when the fire is completely OUT and ashes are COLD. Keep the damper closed when the fireplace is not in use, to prevent unnecessary loss of conditioned room air.
DAMPER CONTROL AND OUTSIDE AIR KIT OPERATION
The damper handle, which opens and closes the damper blade, is located in the upper front face of the fireplace. Pushing the handle forward and up through the keyway slot will free damper blade to automatically open. Pushing the handle forward and down will lock damper blade closed (see Figure 44). Damper must be locked in the full open position before operating fireplace (see Figure 44). Outside air kit handle is located at left hand side of fireplace. Pulling handle out will free outside air door to open. Pushing handle in will lock door closed.
To Close Damper
Damper Weight
Damper Weight
To Open Damper
Figure 44 - Operating Damper Handle
SuperiorFireplaces.us.com 900855-00_B22
Page 23
IMPORTANT NOTICES - CANADA
TECHNICAL SERVICE
IMPORTANT NOTICE A manufactured shroud which has been approved by a national testing agency for use with this fireplace may be used if installed in accordance with the instructions by its manufacturer. A locally fabricated shroud may be used with IHP Shroud Leg Spacer Kit (SLK) in accor­dance with instructions provided with the shroud.
NOTICE: The firebox canopy (hood) must not be mod­ified or replaced with a canopy that may be provided with the unvented decorative room heater.
CAUTION: THE STRUCTURAL INTEGRITY OF THE MANUFACTURED HOME FLOOR, WALL, AND CEIL­ING/ROOF MUST BE MAINTAINED.
WARNING: DO NOT INSTALL IN SLEEPING ROOM
OF MOBILE HOMES.
Canadian code CAN/ULC-S610-M87 and other pertinent codes require stain­less steel chimney for the installation of this fireplace. A Cold Air Climate Kit is also required in Canada and is recommended for cooler regions in the United States. Below, find a list of approved stainless steel parts.
You may have further questions about installation, operation, or troubleshooting. Please contact your IHP dealer for any questions or concerns a. When contacting your dealer please have your model and serial numbers of your fireplace ready. You can also visit our web
site at SuperiorFireplaces.us.com.
REPLACEMENT PARTS
See Pages 24 to 27 for a complete replacement parts list. Use only parts supplied from the manufacturer.
Normally, all parts should be ordered through your IHP distributor or dealer. Parts will be shipped at prevailing prices at time of order.
When ordering repair parts, always give the following information:
1. The model number of the fireplace.
2. The serial number of the fireplace.
3. The part number.
4. The description of the part.
5. The quantity required.
6. The installation date of the fireplace.
If you encounter any problems or have any questions concerning the installation or application of this fireplace, please contact your dealer.
IHP 1508 Elm Hill Pike, Suite 108 Nashville, TN 37210 Visit us at SuperiorFireplaces.us.com
Chimney Parts List for Canada
Catalog No.
F0953 12-12HT 12" Section Double Wall Pipe
F0954 18-12HT 18" Section Double Wall Pipe
F0955 24-12HT 24" Section Double Wall Pipe
F0956 36-12HT 36" Section Double Wall Pipe
F0957 48-12HT* 48" Section Double Wall Pipe
F0958 30E-12HT 30" Offset and Return
F0959 12S-12HT Chimney Support
F0960 RLT-12HT* Round Top w/ Louvers
F0961 AP-12HT Anchor Plate/Collar Assembly (Masonry Fireplaces)
F0951 CAK-12 Cold Air Collar Kit
*When ordered alone, this part cannot ship via parcel delivery services.
Model No.
12" Hi-Temp Wood-burning Chimney
SuperiorFireplaces.us.com900855-00_B 23
Page 24
PARTS
2
1 (4)
3
5
4
MODEL CATALOG NO.
WRT3538WS F3412 WRT3538WH F3413 WRT4038IS F3414 WRT4038IH F3415 WRT3543WS F3416 WRT3543WH F3417 WRT4043IS F3418 WRT4043IH F3419
10
11
6
12
14 (3)
17
7
13
16
30
8 (2)
9 (2)
24
29
23
28
25
26
27
15
22
20 (2)
33
(2)
21
18
19
32 (2)
31 (2)
34
SuperiorFireplaces.us.com 900855-00_B24
Page 25
PARTS
This list contains replaceable parts used in your firebox. When ordering parts, follow the instructions listed under Replacement Parts on page 23 of this manual.
WARNING: Contact an IHP dealer to obtain any of these parts. Never use substitute materials not approved
by IHP. Use of non-approved parts can result in poor performance and safety hazards.
KEY NO. CATALOG NO. DESCRIPTION
1 ** Spacer, Top 4 2 J6998 Collar, Starter 1 3 ** Top Casing, LBR38 1
** Top Casing, LBR43 1
4 ** Insulation Top, LBR38 1
** Insulation Top, LBR43 1
5 ** Assembly, Plenum LBR38 1
** Assembly, Plenum LBR43 1
6 ** Wrapper Casing, LBR38 1
** Wrapper Casing, LBR43 1 7 ** Assembly Gate, Outside Air 1 8 J6934 Plate Cover, Gas Line 2 9 ** Conduit, Gas Line LBRS 2 10 ** Insulation, Dome 1 11 ** Assembly Dome, LBR38 1
** Assembly Dome, LBR43 1 12 ** Assembly, Lintel Extension LBR38 1
** Assembly, Lintel Extension LBR43 1 13 J4359 Bracket, Damper Rod 1 14 ----- See Pages 26 and 27 1 15 ----- See Pages 26 and 27 1 16 ----- See Pages 26 and 27 1 17 ----- See Pages 26 and 27 1 18 ----- See Pages 26 and 27 1 19 ** Bracket, Shipping 1 20 H4035 Bracket, Grate 2 21 ** Cover Plate Side 1 22 ** Cover Plate Side 1 23 ** Wrapper Firebox, LBR38 1
** Wrapper Firebox, LBR43 1 24 ** Duct, Air 1 25 ** Plate Cover, Outside Air Rod 1 26 ** Cover Actuator 1 27 ** Label, Usage 1 28 ** Assembly Base, LBR38 1
** Assembly Base, LBR43 1 29 ** Lip, Ash LBR38 1
** Lip, Ash LBR43 1 30 ** Assembly, Front Face Frame LBR38 1
** Assembly, Front Face Frame LBR43 1 31 16M29 Rod, Screen LBR38 2
16M30 Rod, Screen LBR43 2 32 F3441 Nut, Push-On 2 33 16M27 Panel Screen/Pull, LBR38 2
16M28 Panel Screen/Pull, LBR43 2 34 J4381 Assembly Grate C36 1
J4382 Assembly Grate C42 1
** Not a field replaceable part.
38" 43"
QTY.
SuperiorFireplaces.us.com900855-00_B 25
Page 26
PARTS
This list contains replaceable parts used in your firebox. When ordering parts, follow the instructions listed under Replacement Parts on page 23 of this manual.
WARNING: Contact an IHP dealer to obtain any of these parts. Never use substitute materials not approved
by IHP. Use of non-approved parts can result in poor performance and safety hazards.
WARNING
LIFTING HAZARD
SINGLE -PERSON LIFT COULD
CAUSE INJURY.
USE ASSISTANCE WHEN MOVING
OR LIFTING.
CATALOG NO. DESCRIPTION
F3433 Kit, 38" White Stk Refractory Panels F3434 Kit, 38" White HB Refractory Panels F3437 Kit, 43" White Stk Refractory Panels F3438 Kit, 43" White HB Refractory Panels
1
6
3
IMPORTANT: Installation of refractory panels should be done after the fireplace is placed in a permanent location.
CATALOG NO. DESCRIPTION
F3435 Kit, 38" Ivory Split Stk Masonry Panels F3436 Kit, 38" Ivory Split HB Masonry Panels F3439 Kit, 43" Ivory Split Stk Masonry Panels F3440 Kit, 43" Ivory Split HB Masonry Panels
1
6
3
5
2
2
4
5
4
Stacked Refractory Split HB Masonry
SuperiorFireplaces.us.com 900855-00_B26
Page 27
PARTS
KEY NO. CAT. NO. DESCRIPTION 38" (Stk) 43" (Stk) 38" (HB) 43" (HB) QTY.
1
2 --- Refractory, Bottom LBR38 1 3 --- Refractory, Left and Right RB 1 4 --- Refractory, Left and Right RB 1 5 --- Refractory, Rear RB 1 6 --- Retainer Refractory 3
1 F3437 Kit, 43" White Stk Refractory Panels 1
2 --- Refractory, Bottom LBR43 1 3 --- Refractory, Left and Right RB 1 4 --- Refractory, Left and Right RB 1
5 --- Refractory, Rear RB 1 6 --- Retainer Refractory 3
1 F3434 Kit, 38" White HB Refractory Panels 1
2 --- Refractory, Bottom LBR38 1 3 --- Refractory, Left HB 1 4 --- Refractory, Right HB 1 5 --- Refractory, Rear HB 1 6 --- Retainer Refractory 3
1 F3438 Kit, 43" White HB Refractory Panels 1
2 --- Refractory, Bottom LBR43 1 3 --- Refractory, Left HB 1 4 --- Refractory, Right HB 1 5 --- Refractory, Rear HB 1 6 --- Retainer Refractory 3
F3433
Kit, 38" White Stk Refractory Panels 1
KEY NO. CAT. NO. DESCRIPTION 38" (Split Stk) 43" (Split Stk) 38" (Split HB) 43" (Split HB) QTY.
1
2 --- Assembly, Hearth, Cut LBR38 Ivory 1 3 --- Assembly, Panel, Left Cut Ivory SRB 1 4 --- Assembly, Panel, Right Cut Ivory SRB 1 5 --- Assembly, Panel, Rear Cut Ivory SRB 1 6 --- Retainer Refractory 3
1 F3439 Kit, 43" Ivory Split Stk Masonry Panels 1
2 --- Assembly, Hearth, Cut LBR43 Ivory 1 3 --- Assembly, Panel, Left Cut Ivory SRB 1 4 --- Assembly, Panel, Right Cut Ivory SRB 1
5 --- Assembly, Panel, Rear Cut LBR43 SRB 1 6 --- Retainer Refractory 3
1 F3436 Kit, 38" Ivory Split HB Masonry Panels 1
2 --- Assembly, Hearth, Cut LBR38 Ivory 1 3 --- Assembly, Panel, Left Cut Ivory SHB38 1 4 --- Assembly, Panel, Right Cut Ivory SHB38 1 5 --- Assembly, Panel, Rear Cut Ivory SHB38 1 6 --- Retainer Refractory 3
1 F3440 Kit, 43" Ivory Split HB Masonry Panels 1
2 --- Assembly, Hearth, Cut LBR43 Ivory 1 3 --- Assembly, Panel, Left Cut Ivory SHB43 1 4 --- Assembly, Panel, Right Cut Ivory SHB43 1 5 --- Assembly, Panel, Rear Cut Ivory SHB43 1 6 --- Retainer Refractory 3
F3435
Kit, 38" Ivory Split Stk Masonry Panels 1
SuperiorFireplaces.us.com900855-00_B 27
Page 28
ACCESSORIES
CAT NO. MODEL DESCRIPTION
BI-FOLD GLASS DOORS
F3420 38LBF Bi-Fold Door, 38WB Black
F3421 43LBF Bi-Fold Door, 43WB Black
DOUBLE WALL PIPE
F0932 12-12DM 12" Section Double Wall Pipe Snap Lock
F0933 18-12DM 18" Section Double Wall Pipe Snap Lock
F0934 24-12DM 24" Section Double Wall Pipe Snap Lock
F0935 36-12DM 36" Section Double Wall Pipe Snap Lock
F0936 48-12DM 48" Section Double Wall Pipe Snap Lock
F0953 12-12HT 12" Section Hi-Temp Double Wall Pipe Snap Lock
F0954 18-12HT 18" Section Hi-Temp Double Wall Pipe Snap Lock
F0955 24-12HT 24" Section Hi-Temp Double Wall Pipe Snap Lock
F0956 36-12HT 36" Section Hi-Temp Double Wall Pipe Snap Lock
F0957 48-12HT 48" Section Hi-Temp Double Wall Pipe Snap Lock
30° OFFSET AND RETURN
F0937 30E-12DM 30 Degree Offset and Return
F0958 30E-12HT 30 Degree Hi-Temp Offset and Return
OPTIONAL OUTSIDE AIR KIT FOR FLOOR INSTALLATION
F1091 AK4 Complete Outside Air Kit w/Collars Hood & 3' Flex
OPTIONAL OUTSIDE AIR KIT FOR SIDEWALL INSTALLATION
F1093 AK4F Outside Air Kit Collar, Hood & 3' Flex for Floor Venting
STORM COLLAR
F0946 SC2-1 Storm Collar
EMBER PROTECTOR
J6906 Ember Protector
FIRESTOP SPACER
J4384 1100EFS-10DM 1" Clearance Firestop Spacer
SuperiorFireplaces.us.com 900855-00_B28
Page 29
ACCESSORIES Continued
900599-01
ROOF FLASHING
F0942 V6F-10DM Roof Flashing 0 to 6/12 Pitch
F0943 V12F-10DM Roof Flashing 6/12 to 12/12 Pitch
SQUARE CHASE-TOP TERMINATION
F0948 STL-12D Square Top Termination with Slip Section
F0949 STL-12DMP
Square Top Termination with Slip Section (Pre-Painted Black)
ROUND TOP TERMINATIONS
F0947 RLT-12D Round Top Termination with Louvered Screen
F0960 RLT-12HT Hi-Temp Round Top Termination with Louvered Screen
FIRESTOP THIMBLE
F0944 FST10 Firestop Thimble
LABEL-UL127-50PK
F2659
LABEL-UL127-
50PK
UL127 Venting Label - 50 PK
ADJUSTABLE HOOD
Required when installing a vent-free gas log in this fireplace.
WARNING HOT
•Fire Risk
•Insulation and combustibles must not touch
pipe
•Consult manual for clearance requirements
•Ensure proper connection
WARNING HOT
•Fire Risk
•Insulation and combustibles must not touch
pipe
•Consult manual for clearance requirements
•Ensure proper connection
WARNING HOT
•Fire Risk
•Insulation and combustibles must not touch
pipe
•Consult manual for clearance requirements
•Ensure proper connection
F1764 GA6050 Black Fireplace Hood
SuperiorFireplaces.us.com900855-00_B 29
Page 30
NOTES
______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________
_____________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________
SuperiorFireplaces.us.com 900855-00_B30
Page 31
Innovative Hearth Products
®
Superior
Brand Wood-Burning Fireplace
20 Year Limited Warranty
THE WARRANTY
Innovative Hearth Products ("IHP") 20 Year Limited Warranty warrants your Superior® Brand wood burning fireplace ("Product") to be free from defects in materials and workmanship at the time of manufacture. The Product body, firebox and ceramic glass carry the 20 Year Limited Warranty. Ceramic glass carries the 20 Year Limited Warranty against thermal breakage only. After installation, if covered components manufactured by IHP are found to be defective in materials or workmanship during the 20 Year Limited Warranty period and while the Product remains at the site of the original installation, IHP will, at its option, repair or replace the covered components. If repair or replacement is not commercially practical, IHP will, at its option, refund the purchase price or wholesale price of the IHP product, whichever is applicable. IHP will also pay IHP prevailing labor rates, as determined in its sole discretion, incurred in repairing or replacing such components for up to five years. THERE ARE EXCLUSIONS AND LIMITATIONS to this 20 Year Limited Warranty as described herein.
COVERAGE COMMENCEMENT DATE
Warranty coverage begins on the date of purchase. In the case of new home construction, warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the Product by an independent IHP dealer/distributor, whichever occurs earlier. The warranty shall commence no later than 24 months following the date of product shipment from IHP, regardless of the installation or occupancy date.
EXCLUSIONS AND LIMITATIONS
This 20 Year Limited Warranty applies only if the Product is installed in the United States or Canada and only if operated and maintained in accordance with the printed instruc­tions accompanying the Product and in compliance with all applicable installation and building codes and good trade practices.
This warranty is non-transferable and extends to the original owner only. The Product must be purchased through a listed supplier of IHP and proof of purchase must be provided. The Product body and firebox carry the 20 Year Limited Warranty from the date of installation. Vent components, trim components, paint and applied stains are excluded from this 20 Year Limited Warranty. The following do not carry a 20 Year Limited Warranty but are warranted as follows:
Air tubes, baffles and brick retainers – Repair or replacement for one year from the date of installation Cast iron parts – Replacement for one year from date of installation Catalyst – Carries a separate warranty. Refer to the warranty certificate provided for that part Electrical components – Repair or replacement for one year from the date of installation Fireplace screens, refractory and side shields (metal or refractory) – Repair or replacement for two years from date of installation. Excludes hairline cracks. Fuel grates –These parts are considered consumable accessories and therefore are not warranted, with the exception of defects in material or workmanship which
are covered for 90 days from the date of installation Gaskets – Replacement for one year from date of installation Gold & nickel plating – Replacement for two years from date of installation. Excludes tarnishing
Optional glass doors – Repair or replacement for 90 days from the date of installation Refractory & screens – Replacement for two years from date of installation. Excludes hairline cracks Removable air tubes – Repair or replacement for seven years from date of installation. IHP prevailing labor rates for years one through five.
Labor coverage – Prevailing IHP labor rates apply for the warranty period of the component. Parts not otherwise listed carry a 90 day warranty from the date of installation. Whenever practicable, IHP will provide replacement parts, if available, for a period of 10 years from the last date of manufacture of the Product.
IHP will not be responsible for: (a) damages caused by normal wear and tear, accident, riot, fire, flood or acts of God; (b) damages caused by abuse, negligence, misuse, or unauthorized alteration or repair of the Product affecting its stability or performance. (The Product must be subject to normal use with approved fuels listed in the Operation Manual provided with the product. This includes burning such fireplace fuels as wood and natural or propane gas. Fuel products with abnormal burning characteristics, including but not limited to fuel such as driftwood, coal or plywood and wood products using a binder may burn at excessive temperatures and may cause damage to the Product or may cause it to function improperly.); (c) damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with the Product; (d) damages, repairs or inefficiency resulting from faulty installation or application of the Product.
Coverage of this 20 Year Limited Warranty is conditional upon use of an adequate fuel grate on factory-built fireplaces only, when applicable. IHP is not responsible for inadequate fireplace system draft caused by air conditioning and heating systems, mechanical ventilation systems, or general construction condi­tions which may generate negative air pressure in the room in which the appliance is installed. Additionally IHP assumes no responsibility for smoking conditions caused by inadequate chimney height, adjoining trees or buildings, adverse wind conditions or unusual environmental factors and conditions. Certain IHP Products are listed for use with Security Chimneys International, Ltd. or IHP chimney systems only. Use of chimney components other than that specified in the Product manual will void the Product warranty.
This 20 Year Limited Warranty covers only parts and labor as provided herein. In no case shall IHP be responsible for materials, components or construction which are not manufactured or supplied by IHP or for the labor necessary to install, repair or remove such materials, components or construction. Additional utility bills incurred due to any malfunction or defect in equipment are not covered by this 20 Year Limited Warranty. All replacement or repair components will be shipped F.O.B. from the nearest stocking IHP factory.
LIMITATION ON LIABILITY
It is expressly agreed and understood that IHP’s sole obligation and the purchaser’s exclusive remedy under this warranty, under any other warranty, expressed or implied, or in contract, tort or otherwise, shall be limited to replacement, repair, or refund, as specified herein.
In no event shall IHP be liable for any incidental or consequential damages caused by defects in the Product, whether such damage occurs or is discovered before or after replacement or repair, and whether such damage is caused by IHP’s negligence. IHP has not made and does not make any representation or warranty of fitness for a particular use or purpose, and there is no implied condition of fitness for a particular use or purpose.
IHP makes no expressed warranties except as stated in this 20 Year Limited Warranty. The duration of any implied warranty is limited to the duration of this expressed warranty.
No one is authorized to change this 20 Year Limited Warranty or to create for IHP any other obligation or liability in connection with the Product. Some states and provinces do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. The provisions of this 20 Year Limited Warranty are in addition to and not a modification of or subtraction from any statutory warranties and other rights and remedies provided by law.
INVESTIGATION OF CLAIMS AGAINST WARRANTY
IHP reserves the right to investigate any and all claims against this 20 Year Limited Warranty and to decide, in its sole discretion, upon the method of settlement.
To receive the benefits and advantages described in this 20 Year Limited Warranty, the appliance must be installed and repaired by a licensed contractor approved by IHP. Contact IHP at the address provided herein to obtain a listing of approved dealers/distributors. IHP shall in no event be responsible for any warranty work done by a contrac-
tor that is not approved without first obtaining IHP's prior written consent.
HOW TO REGISTER A CLAIM AGAINST WARRANTY
In order for any claim under this warranty to be valid, you must contact the IHP dealer/distributor from which you purchased the product. If you cannot locate the dealer/ distributor, then you must notify IHP in writing. IHP must be notified of the claimed defect in writing within 90 days of the date of failure. Notices should be directed to the IHP Warranty Department at 1769 East Lawrence Street; Russellville, AL 35654 or visit our website at WWW.SUPERIORFIREPLACES.US.COM.
Printed in U.S.A. © 2013 Innovative Hearth Products
P/N 900224-00, Rev. B 02/2018
SuperiorFireplaces.us.com900855-00_B 31
Innovative Hearth Products 1769 East Lawrence Street • Russellville, AL 35654
Page 32
SuperiorFireplaces.us.com
P900855-00
Record the following important information about your fireplace:
Fireplace model number
Fireplace serial number
Date fireplace was Installed
Dealer name
Innovative Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information.
Printed in U.S.A. © 2017 Innovative Hearth Products LLC P/N 900855-00 Rev. B 02/2018