Superior Fireplaces VRT3042, VCT3042, VRT3036, VCT3036 Quick Start Manual

Page 1
VRT3042 AND VCT3042
A
D
F
E
VENT-FREE FIREPLACES
0” Clearance Permitted
C
B
Framing Dimensions
Models A B C
42” Models
Location
Outside
Air Kit
1099 mm
1226 mm
23-1/4”
4-1/2”
40-1/8”
24”
597 mm
Firebox Top View
36-1/4”6-1/8”
50-1/8”
42”
Models D E F
42” Models
1226 mm
27-1/8”
2-3/8”
4-3/8”
22-3/8”
82”
2083 mm
40-1/8”
58”
1474 mm
44.253
Fireplace Dimensions
12-5/8”
10-1/2”
10-7/8”
14-1/4”
Left Side View
Diagrams, illustrations and photographs are not to scale. Consult installation instructions. Product designs, materials, dimensions, specifications, colors, and prices are subject to change or discontinuance without notice.
P/N 900660-02, REV. NC, 04/2016
8-1/4”
2-5/8”
7-1/8”
3-1/8”
42”
48-1/4”
1-3/8”
Front View
8-1/4”
2-5/8”
7-5/8”
10-5/8”
13-3/8”
3-3/8”
Electrical
Outlet
Right Side View
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Page 1 of 2
Page 2
VRT3042 AND VCT3042
USC
Wall board or facing
Cat. # Model Type Interior Weight Cu. Ft.
F0306 VRT3042B Radiant Black 224 lb. 32 F0307 VCT3042B Louver Black 224 lb. 32 F0316 VRT3042WS Radiant WS refractory 224 lb. 32 F0317 VCT3042WS Louver WS refractory 224 lb. 32 F0318 VRT3042RS Radiant RS refractory 224 lb. 32 F0319 VCT3042RS Louver RS refractory 224 lb. 32 F0320 VRT3042RH Radiant RH refractory 224 lb. 32 F0321 VCT3042RH Louver RH refractory 224 lb. 32
Product Information
Mantel Clearance
Mantel Shelf Note: Any portion of the mantel shelf must NOT extend beyond this profile.
Noncombustible Material May Project Off this Surface above the Firebox Hood
Note: All vertical measurements are from top of fireplace hood opening to bottom of mantel shelf. These minimum clearances replace any other recommended clearances supplied with your ANSI Z21.11.2 approved gas logs.
Mantel Depth Allowed
1-1/2” (38 mm) max.
6-3/4” (172 mm) max.
12” (305 mm) max.
12
(305)
Clearances
material (above firebox) may be of combustible material, including decorative mantel ornaments or other similar projec­tions off of the facing material.
Framing Material
Firebox
Wire-mesh Screen
Inch (millimeter)
Mantel from Top of Opening
12” (305 mm)
16” (407 mm)
20” (508 mm)
12 (305)
6-3/4 (172)
1-1/2 (38)
Supplied Firebox Hood Must Be Used at All Times
16
(407)
20
(508)
These appliances comply with National
®
Report No. F12-020
Safety Standards and are listed by PFS Cor poration to ANSI Z21.91 Ventless Firebox Enclosures for Gas-Fired Unvented Decora tive Room Heaters and is approved for use with appliances listed to ANSI Z21.11.2 decorative type unvented room heaters.
-
-
Listing Information
14
(356)16(407)
12-1/4 (312)
10-1/2 (267)
8-3/4 (223)
7 (178)
5-1/4 (134)
3-1/2 (89)
1-3/4 (45)
7/8 (23)
1/2 (13)
Inch (millimeter)
Example
1/2
(13)1(26)2(51)
4
6
(102)
(153)8(204)10(254)12(305)
Minimum Wall and Ceiling Clearances
A. Clearances from the side of the fireplace cabinet to any combustible
material and wall should follow diagram shown here.
Example: The face of a mantel, bookshelf, etc. is made of combustible
material and protrudes 3-1/2” from the wall. This combustible material must be 4” from the side of the fireplace cabinet.
B. Clearances from the top of the firebox opening to the ceiling should not
be less than 42”.
C. When the firebox is installed directly on carpeting, vinyl tile or other
combustible material, other than wood flooring, the firebox should be installed on a metal or wood panel extending the full width and depth of the enclosure.
D. Clearances from the bottom of firebox to the floor is 0”.
Printed in U.S.A. © 2016 Innovative Hearth Products
P/N 900660-02 REV. NC 04/2016
Nails or Wood Screws
Nailing Flanges
Nailing Flange
Typical Locations
CORNER
INTERNAL WALL INSTALLATION
FULL PROJECTION INSTALLATION
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Specifications and clearances are subject to change without notice. Refer to Installation and Operation Manual before installation of these appliances for updated dimensions and instructions.
INSTALLATION
FLUSH
INSTALLATION
Page 2 of 2