VRT3042 AND VCT3042
VENT-FREE FIREPLACES
0” Clearance Permitted
C
B
Framing Dimensions
Models A B C
42” Models
Location
Outside
Air Kit
43-3/4”
1099 mm
48-1/4”
1226 mm
23-1/4”
4-1/2”
40-1/8”
24”
23-1/2”
597 mm
Firebox Top View
36-1/4”6-1/8”
50-1/8”
42”
Models D E F
42” Models
48-1/4”
1226 mm
27-1/8”
2-3/8”
4-3/8”
22-3/8”
82”
2083 mm
40-1/8”
58”
1474 mm
44.253
Fireplace Dimensions
12-5/8”
10-1/2”
10-7/8”
14-1/4”
Left Side View
Diagrams, illustrations and photographs are not to scale. Consult installation instructions. Product designs,
materials, dimensions, specifications, colors, and prices are subject to change or discontinuance without notice.
P/N 900660-02, REV. NC, 04/2016
8-1/4”
2-5/8”
7-1/8”
3-1/8”
42”
48-1/4”
1-3/8”
Front View
8-1/4”
2-5/8”
7-5/8”
10-5/8”
13-3/8”
3-3/8”
Electrical
Outlet
Right Side View
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Page 1 of 2

VRT3042 AND VCT3042
Cat. # Model Type Interior Weight Cu. Ft.
F0306 VRT3042B Radiant Black 224 lb. 32
F0307 VCT3042B Louver Black 224 lb. 32
F0316 VRT3042WS Radiant WS refractory 224 lb. 32
F0317 VCT3042WS Louver WS refractory 224 lb. 32
F0318 VRT3042RS Radiant RS refractory 224 lb. 32
F0319 VCT3042RS Louver RS refractory 224 lb. 32
F0320 VRT3042RH Radiant RH refractory 224 lb. 32
F0321 VCT3042RH Louver RH refractory 224 lb. 32
Product Information
Mantel Clearance
Mantel Shelf
Note: Any portion of the
mantel shelf must NOT
extend beyond this profile.
Noncombustible
Material May
Project Off this
Surface above
the Firebox Hood
Note: All vertical
measurements are
from top of fireplace
hood opening to
bottom of mantel shelf.
These minimum
clearances replace any
other recommended
clearances supplied
with your ANSI Z21.11.2
approved gas logs.
Mantel Depth Allowed
1-1/2” (38 mm) max.
6-3/4” (172 mm) max.
12” (305 mm) max.
12
(305)
Clearances
material (above
firebox) may be of
combustible material,
including decorative
mantel ornaments or
other similar projections off of the facing
material.
Framing
Material
Firebox
Wire-mesh
Screen
Inch (millimeter)
Mantel from Top of Opening
12” (305 mm)
16” (407 mm)
20” (508 mm)
12 (305)
6-3/4 (172)
1-1/2 (38)
Supplied
Firebox Hood
Must Be Used
at All Times
16
(407)
20
(508)
These appliances comply with National
®
Report No. F12-020
Safety Standards and are listed by PFS Cor
poration to ANSI Z21.91 Ventless Firebox
Enclosures for Gas-Fired Unvented Decora
tive Room Heaters and is approved for use
with appliances listed to ANSI Z21.11.2
decorative type unvented room heaters.
-
-
Listing Information
14
(356)16(407)
12-1/4 (312)
10-1/2 (267)
8-3/4 (223)
7 (178)
5-1/4 (134)
3-1/2 (89)
1-3/4 (45)
7/8 (23)
1/2 (13)
Inch (millimeter)
Example
1/2
(13)1(26)2(51)
4
6
(102)
(153)8(204)10(254)12(305)
Minimum Wall and Ceiling Clearances
A. Clearances from the side of the fireplace cabinet to any combustible
material and wall should follow diagram shown here.
Example: The face of a mantel, bookshelf, etc. is made of combustible
material and protrudes 3-1/2” from the wall. This combustible material
must be 4” from the side of the fireplace cabinet.
B. Clearances from the top of the firebox opening to the ceiling should not
be less than 42”.
C. When the firebox is installed directly on carpeting, vinyl tile or other
combustible material, other than wood flooring, the firebox should be
installed on a metal or wood panel extending the full width and depth of
the enclosure.
D. Clearances from the bottom of firebox to the floor is 0”.
Printed in U.S.A. © 2016 Innovative Hearth Products
P/N 900660-02 REV. NC 04/2016
Nails or Wood
Screws
Nailing Flanges
Nailing Flange
Typical Locations
CORNER
INTERNAL WALL
INSTALLATION
FULL
PROJECTION
INSTALLATION
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Specifications and clearances are subject to change without notice.
Refer to Installation and Operation Manual before installation of these
appliances for updated dimensions and instructions.
INSTALLATION
FLUSH
INSTALLATION
Page 2 of 2