Superior WRE3836WS, WRE3836WH, WRE3836RH, WRE3836RS Installation And Operation Instructions Manual

Installation and Operation Instructions
PFS
SuperiorTM Wood-Burning Outdoor Fireplace
P/N 127023-01 Rev. A 02/2014
P127023-01
Models
®
WRE3836WS WRE3836WH WRE3836RS WRE3836RH
SAVE THIS BOOK
This book is valuable. In addition to instructing you on how to install and maintain your appliance, it also contains information that will enable you to obtain replacement parts or accessory items when needed. Keep it with your other important papers.
INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.
This wood burning fireplace complies with UL127 CAN/ULC-S610-M87 standard as a FACTORY BUILT FIREPLACE.
This fireplace is approved for use as a wood furning fireplace or for use with a vented gas log approved to ANSI Z21.60 or Z21.84 standards or for use with a vent-free gas log heater approved to ANSI Z21.11.2 standard.
FOR CANADA: The authority having jurisdiction (such as the municipal building department, fire department, etc.) should be contacted before installation to determine the need to obtain a permit.
Installateur : Laissez cette notice avec l’appareil. Consommateur : Conservez cette notice pour consultation ultérieure.
Ce foyer au bois est conforme aux UL 127 CAN/ULC­S610-M87 norme comme une USINE CONSTRUITE CHEMINÉE.
POUR LE CANADA: L’autorité compétente (comme le service municipal du bâtiment, les pompiers, etc.) doit être contacté avant l’installation afin de déterminer la nécessité d’obtenir un permis.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.
— Do not store or use gasoline or other
flammable vapors and liquids in the vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch; do not
use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.
— Installation and service must be performed
by a qualified installer, service agency or the gas supplier.
AVERTISSEMENT : Assurez-vous de bien suivre les instructions données dans cette notice pour réduire au minimum le risque d’incindie ou d’explosion ou pour éviter tout dommage matériel, toute blessure ou la mort.
— Ne pas entreposer ni utilizer d’essence ni d’autres
vapeurs ou liquides inflammables dans le voisinage de cet appareil ou de tout autre appareil.
— QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ :
• Ne pas tenter d’allumer d’appareil.
• Ne touchez à aucan interrupteur. Ne pas vous
servir des téléphones se trouvant dans le bâtiment où vous trouvez.
• Appelez immédiatement votre fournisseur de gaz depuis un voisin. Suivez les instructions du fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz, appelez le service des incindies.
— L’installation et l’entretien doivent être assurés par un
installateur ou un service d’entretien qualifié ou par le fournisseur de gaz.
CATALYTIC FIREPLACE OWNER’S
PFS
USC
®
CATALYTIC FIREPLACE
36" WOOD BURNING OUTDOOR
FIREPLACE
OPERATION AND INSTALLATION MANUAL
These models meet the EPA Wood Burning Fireplace Program Phase 2 emission level. NOTE: To ensure proper
replace operation, the catalyst should be replaced at a minimum of 3 years and a maximum of 5 years.
SAVE THIS BOOK
This book is valuable. In addition to instructing you on how to install and maintain your appliance, it also contains information that will enable you to obtain re­placement parts or accessory items when needed. Keep it with your other important papers.
This replace is approved for use as a wood burning re-
place or for use with a vented gas log approved to ANS Z21.60 and Z21.84 standards or for use with a vent-free gas log heater approved to ANS Z21.11.2 standard. A INNOVA-
TIVE HEARTH PRODUCTS hood must be installed when using a vent-free log heater (see Accessories, page 21).
This wood burning replace complies with UL127­CAN/ULC-S610-M87 standard as a FACTORY BUILT FIREPLACE.
FOR CANADA: The authority having jurisdiction (such as the municipal building department, re department, etc.) should be contacted before installation to deter­mine the need to obtain a permit.
INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.
For more information, visit www.SuperiorFireplaces.US.com
Safety .................................................................. 3
TABLE OF CONTENTS
Specications ...................................................... 4
Fireplace Installation............................................ 5
Venting Installation .............................................. 7
PureFire Installation........................................... 14
Optional Gas Line Installation............................ 14
Operation and Maintenance .............................. 15
SAFETY
HearthCAT™Emissions Control System ........... 17
Parts .................................................................. 19
Replacement Parts ............................................ 21
Technical Service............................................... 22
Accessories ....................................................... 22
Warranty ............................................................ 24
WARNING: Improper instal-
lation, adjustment, alteration,
service or maintenance can
cause injury, property damage or
loss of life. Refer to this manual for assistance or additional in-
formation. Consult a qualied installer or local distributor.
IMPORTANT: Check local codes before installing this replace.
Before beginning installation of this replace, read these instructions through completely.
• This INNOVATIVE HEARTH PRODUCTS fireplace and its components are safe when installed according to this installation manual. Unless you use IHP components, which have been designed and tested for the replace system, you may cause a re hazard.
• The INNOVATIVE HEARTH PRODUCTS warranty will be voided by and IHP dis­claims any responsibility for the following actions.
a. Modification of the fireplace, com-
ponents, doors, air inlet system and damper control.
b. Use of any component part not manu-
factured or approved by INNOVATIVE HEARTH PRODUCTS in combination
with an IHP replace system. Proper installation is the most important step in ensuring safe and continuous operation of replace. Consult the local building codes as to the particular requirements concerned with the installation of all factory built replaces.
NOTICE: The firebox canopy (hood) must not be modified or replaced with a canopy that may be provided with the un-
vented decorative room heater.
WARNING: Do not install a
replace insert in this box unless
the manufacturer's instructions
with the insert specically state this replace has been tested for
use with this insert.
FOR YOUR SAFETY
• Do not store or use gasoline or any other ammable vapors or liquids in the vicinity of this or any other appliance.
• Due to high temperatures, the appliance should be located out of trafc and away from
furniture and draperies.
• Do not place clothing or other ammable materials on or near
the appliance.
• Never leave children unat­tended when a re is burning in the replace.
WARNING: Use solid wood
or processed solid fuel re logs only. When processed wood fuel re logs are used, do not poke or stir the logs while they are burning. Use only re logs that have been evaluated for the application in replace and refer to re log warnings and caution markings on packaging
prior to use.
This replace is not intended to be used as a substitute for a fur-
nace to heat an entire home. Use
for supplemental heat only.
SPECIFICATIONS
GAS LINE
0" TO
TOP
SPACERS
0.75" AIR SPACE BACK AND SIDES
OUTSIDE AIR (LEFT SIDE ONLY)
0" TO BOTTOM
21"
1" AIRSPACE TO COMBUSTIBLE MATERIAL
HEARTH
EXTENSION 8" EACH SIDE
29"
52" X 18"
ELECTRICAL OUTLET
NO COMBUSTIBLE MATERIAL ON FACE
8.717"
11.217"
COMBUSTIBLE WALL BOARD
11.435"
NOT LESS THAN 12" TO PERPENDICULAR SIDEWALL
12.5"
RIGHT SIDE
7.092"
LEFT SIDE
14.437"
22"
8.717"
KNOCK
OUTS
9.125"
3.5"
AIR KIT KNOCK OUT
GAS LINE KNOCK OUTS
9.125"
3.5"
14.25"
41"
35" 41"
41.250"
0.625"
37"
8"
1"
CAUTION: THE STRUCTURAL
INTEGRITY OF THE MANUFACTURED
HOME FLOOR, WALL, AND CEILING/
ROOF MUST BE MAINTAINED.
www.SuperiorFireplaces.US.com
32.5"
1"
21"
ROUND TOP TERMINATION
SQUARE CHASE-TOP
TERMINATION
WARNING: DO NOT INSTALL IN
SLEEPING ROOM OF MOBILE HOMES.
127023-01A4
FIREPLACE INSTALLATION
SELECTING LOCATION
To determine safest and most efcient location for replace, you must take into consideration the following guidelines:
1. Location must allow for proper clearances (see Figures 1 and 2).
2. Consider a location where replace will not be affected by drafts, air conditioning ducts, windows or doors.
3. A location that avoids cutting of joists or roof rafters will make installation easier.
4. An outside air kit is available with this replace (see Optional Outside Air Kit on page 7).
MINIMUM CLEARANCE TO COMBUSTIBLES
Back and sides of replace 3/4" minimum* Floor** 0" minimum Perpendicular wall to opening 14" minimum Top spacers 0" minimum Mantel clearances see Mantels, page 6 Chimney outer pipe surface 1" minimum
* Not required at nailing anges ** See step 2 of Framing
WARNING: Do not pack re­quired air spaces with insulation or other materials.
Minimum/Maximum Chimney Height
Minimum height of chimney, measured from base of replace to ue gas outlet of termina­tion, is 14.5 feet for straight ue or a ue with one elbow set. Maximum distance between elbows is 6 feet. For systems with two elbow sets, minimum height is 22 feet. Maximum height of any system is 50 feet. This measure­ment includes replace, chimney sections and height of termination assembly at level of ue gas outlet (see Figure 19, page 12).
Minimum/Maximum Chimney Height for
Outdoor Installation
The minimum height of the chimney, mea­sured from the base of the replace to the ue gas outlet of the termination, is 7 1/2 feet (minimum of 4 feet of chimney pipe sections required for outdoor installation).
FRAMING
1. Frame opening for replace using dimen­sions shown in Figures 1 and 2.
2. If replace is to be installed directly on carpeting, tile (other than ceramic) or any combustible material other than wood ooring, replace must be installed upon a metal or wood panel extending full width and depth of replace.
3. Set replace directly in front of this open­ing and slide unit back until nailing anges touch side framing.
4. Check level of replace and shim with sheet metal if necessary.
5. Before securing fireplace to prepared framing, ember protector must be placed between hearth extension (not included) and under bottom front edge of replace to protect against glowing embers falling through. If replace is to be installed on a raised platform, a Z-type ember protec­tor (not included) must be fabricated to t your required platform height. Ember protector should extend under replace a minimum of 1 1/2". Ember protector should be made of galvanized sheet metal (28 gauge minimum) to prevent corrosion.
6. Using screws or nails, secure replace to framing through anges located on sides of replace.
41.75"
41.75"
21.875"
Figure 1 - Framing Dimensions
24.399"
17.253"
52.183"
73.798"
3
MAINTAIN
/4" CLEARANCE AT SIDES AND BACK OF FIREPLACE
3
/4" CLEARANCE NOT REQUIRED AT NAILING FLANGES
Figure 2 - Corner Installation
127023-01A 5
www.SuperiorFireplaces.US.com
FIREPLACE INSTALLATION
DRAIN PAN (DP36)
For outdoor installations, the replace enclo­sure must allow for adequate drainage and fresh air ventilation. It is recommended that a sealed, corrosion resistant catch pan with provision for drainage be installed under the replace within the replace enclosure (see Accessories on page 21).
HEARTH EXTENSION
A hearth extension projecting a minimum of 16" in front of and a minimum of 8" beyond each side of replace opening is required to protect combustible oor construction in front of replace. Fabricate a hearth extension using a material which meets the following specications: a layer of noncombustible, inorganic material having a thermal conductiv­ity of K=0.84 BTU IN/FT, HR. F (or less) at 1" thick. For example, if material selected has a K factor of 0.25, such as glass ber, the following formula would apply:
0.25 x 1.0" = 0.30" thickness required
0.84 Thermal conductivity "K" of materials can be
obtained from manufacturer or supplier of noncombustible material. If hearth extension is to be covered, use noncombustible mate­rial such as tile, slate, brick, concrete, metal, glass, marble, stone, etc. Provide a means to prevent hearth extension from shifting and seal gap between replace frame and hearth extension with a noncombustible material (see Figure 3).
WARNING: Hearth extension
is to be installed only as shown
in Figure 3.
Fireplace Front
Ember Protector
Fireplace Front Raised Hearth
Ember Protector
Fireplace Front Elevated
Ember Protector
Figure 3 - Hearth Extension
Seal Gap
Hearth
Extension
Seal Gap
www.SuperiorFireplaces.US.com
127023-01A6
FIREPLACE INSTALLATION
Continued
MANTELS
A mantel may be installed if desired (see Figures 4 and 5). Woodwork such as wood trims, mantels or any other combustible material projecting from front face, must not be placed within 9" of replace opening and within 6" of top louver opening. Combustible materials above 9" and projecting more than
1 1/2" from replace must not be placed less
than 12" from top opening of replace (NFPA STD 211, Sec. 7-3.3.3).
12 1/4" Ref.
Combustible Material
Mantels or any other combustible material also may come up to the side edge of the stainless steel face of the replace just as long as the projection from the front face fall within the limit shown in Figure 4 and 5.
Top View of Fireplace
FIREBOX
8.0"
33°
SAFE ZONE
2" Max.
3.0"
Safe
6"
Ref.
12" Min.
33°
3" Nom.
11/2" Max.
9" Min.
Fireplace Opening
Figure 5 - Mantel Clearances to
Combustible Material
Zone for Projection of Combustible Materials
Upper
Section of
Fireplace
VENTING INSTALLATION
OPTIONAL OUTSIDE AIR KIT (MODEL AK4/AK4F)
Installation of an outside air kit should be performed during rough framing of replace due to the nature of it's location. Outside com­bustion air is accessed through a vented crawl space (AK4F) or through a sidewall (AK4). See Figure 23 on page 15 for instruction of operating air kit.
CAUTION: Combustion air
inlet ducts shall not terminate in attic space.
Min. to
Perpendicular
Side Wall
12"
Figure 5 - Mantel Clearances to
Combustible Material
Combustible Material Must Not Overlap Front Face
The maximum height for the air vent can not exceed 3 feet below the ue gas outlet of the
termination.
CHIMNEY PIPE
INNOVATIVE HEARTH PRODUCTS chimney system consists of 12", 18", 24", 36" and 48" snap-lock, double-wall pipe segments, planned for maximum adaptability to individual site requirements. Actual lengths gained after tting overlaps must be taken into consider­ation (lineal gain) and are given in lineal gain chart (see Figure 7, page 7). Lineal gain is actual measurable length of a part after two or more parts are connected. For Canada, use chimney parts designated "HT".
127023-01A 7
www.SuperiorFireplaces.US.com
VENTING INSTALLATION
Continued
Secure to Collars with Metal Tape, Screws or Straps (Min. of 1/4" x 20" in size)
Air Inlet Location Must Allow
For Bushes
or Snow
12 3/8"
Galvanized Outer Pipe
8" Stainless Inner Pipe
Hemmed End
Air Inlet
Vented Crawl Space (Check Local Codes Before Installing in a Vented Crawl Space)
Eyebrow
Vent Hood Required for Wall Installation
Figure 6 - Outside Air Kit
WARNING: The opening in
collar around chimney at top of replace must not be obstructed. Never use blown insulation to ll chimney enclosure.
ASSEMBLY AND INSTALLATION OF DOUBLE WALL CHIMNEY SYSTEM
Each double wall chimney section consists of a galvanized outer pipe, a stainless steel in­ner ue pipe and a wire spacer. Pipe sections must be assembled independently as chimney is installed. When connecting chimney directly to replace, inner ue pipe section must be installed rst with lanced side up. Outer pipe section can then be installed over ue pipe section with hemmed end up. Press down on each pipe section until lances securely engage hem on replace starter. The wire will assure proper spacing between inner and outer pipe sections.
Note: For Canada, use chimney parts desig­nated HT.
PART NO. DESCRIPTION GAIN
36" Fireplace 37 1/2"
12-8DM
12-8HT
18-8DM
18-8HT
24-8DM
24-8HT
36-8DM
36-8HT
48-8DM
48-8HT
RT-8DM Round Termination 6 7/8"*
RTL-8DM Round Termination 7 3/4"*
RLT-8DM Round Termination 7 1/2"
RTT-8DM
RTTL-8DM
RLTT-8DM
ET-8DM Square Chase-Top 12"*
ETO-8DM
ETL-8DM
ETLO-8DM
LINEAL GAIN
Pipe Section 10 5/8"
Pipe Section 16 5/8"
Pipe Section 23 5/8"
Pipe Section 34 5/8"
Pipe Section 46 5/8"
Round Termination
with Slip Section
Round Termination
with Slip Section
Round Termination
with Slip Section
Square Chase-Top
with Mesh
Square Chase-Top
with Slip Section
Square Chase-Top
with Mesh & Slip
Section
6 7/8" to
23 1/8"* 8 1/2" to 21 1/2"* 7 1/2" to 21 1/4"*
12"*
7" to 15"*
12" to
25 1/2"*
* The lineal gain for the terminations is measured to the ue gas outlet height.
Figure 7 - Lineal Gain
Opening in collar around
chimney at top of replace must not be obstructed. Never use blown insulation to ll chimney
enclosure.
www.SuperiorFireplaces.US.com
127023-01A8
VENTING INSTALLATION
Continued
Continue to assemble chimney sections as outlined, making sure that both inner and outer pipe sections are locked together. When installing double wall snap-lock chimney to­gether, it is important to assure joint between chimney sections is locked. Check by pulling chimney upward after locking. Chimney will not come apart if properly locked. It is not necessary to add screws to keep chimney to­gether (exception - see Figure 10, page 9).
USING ELBOW OFFSETS (30E-8DM)
1. To achieve desired offset, you may install combinations of 12", 18", 24", 36" and 48" length of double wall pipe (see offset chart on page 9 and Figure 8).
Note: For systems with 2 elbow sets, mini-
mum height is 22 feet. Maximum height for any system is 50 feet.
2. Chimney weight above offset rests on return elbow. Straps must be securely nailed to rafters or joists (see Figure 9, details A and B on page 9).
3. Maximum length of pipe between supports (return elbow or 12S-8DM) is 6' of angle run. Maximum of two 6' angle run sections per chimney system (see Figure 8).
4. All pipe connections between offset and return must be secured with two screws on outer pipe only (see Figure 10, page
9). Do not penetrate inner stainless.
Offset Elbow
Return Elbow
6' Max.
6' Max.
Return Elbow
Offset Elbow
Return Elbow
Offset
Offset Elbow
A
Elbow
Figure 8 - Typical Offset Installation
6' Max.
B C
6' Max.
Offset Elbow
Return Elbow
Ceiling Support Pipe 12S-8DM
Return Elbow
6' Max.
6' Max.
127023-01A 9
www.SuperiorFireplaces.US.com