Superior Installation And Operation Instructions Manual
Specifications and Main Features
Frequently Asked Questions
User Manual
Installation and Operation Instructions
PFS
SuperiorTM Wood-Burning Outdoor Fireplace
P/N 127023-01 Rev. A 02/2014
P127023-01
Models
®
USC
WRE3836WSWRE3836WHWRE3836RSWRE3836RH
SAVE THIS BOOK
This book is valuable. In addition to instructing you on how to install and maintain your appliance, it also contains
information that will enable you to obtain replacement parts or accessory items when needed. Keep it with your other
important papers.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
This wood burning fireplace complies with
UL127 CAN/ULC-S610-M87 standard as a
FACTORY BUILT FIREPLACE.
This fireplace is approved for use as a wood furning fireplace or for use with a vented gas log approved to
ANSI Z21.60 or Z21.84 standards or for use with a vent-free gas log heater approved to ANSI Z21.11.2 standard.
FOR CANADA: The authority having jurisdiction
(such as the municipal building department, fire
department, etc.) should be contacted before
installation to determine the need to obtain a
permit.
Installateur : Laissez cette notice avec l’appareil.
Consommateur : Conservez cette notice pour consultation ultérieure.
Ce foyer au bois est conforme aux UL 127 CAN/ULCS610-M87 norme comme une USINE CONSTRUITE
CHEMINÉE.
POUR LE CANADA: L’autorité compétente (comme le
service municipal du bâtiment, les pompiers, etc.) doit
être contacté avant l’installation afin de déterminer la
nécessité d’obtenir un permis.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only)
or mobile home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated
on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
WARNING: If the information in these
instructions is not followed exactly, a fire or
explosion may result causing property damage,
personal injury or death.
— Do not store or use gasoline or other
flammable vapors and liquids in the vicinity
of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch; do not
use any phone in your building.
• Immediately call your gas supplier from
a neighbor’s phone. Follow the gas
supplier’s instructions.
• If you cannot reach your gas supplier, call
the fire department.
— Installation and service must be performed
by a qualified installer, service agency or the
gas supplier.
AVERTISSEMENT : Assurez-vous de bien suivre les
instructions données dans cette notice pour réduire au
minimum le risque d’incindie ou d’explosion ou pour éviter
tout dommage matériel, toute blessure ou la mort.
— Ne pas entreposer ni utilizer d’essence ni d’autres
vapeurs ou liquides inflammables dans le voisinage
de cet appareil ou de tout autre appareil.
— QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ :
• Ne pas tenter d’allumer d’appareil.
• Ne touchez à aucan interrupteur. Ne pas vous
servir des téléphones se trouvant dans le bâtiment
où vous trouvez.
• Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions du
fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incindies.
— L’installation et l’entretien doivent être assurés par un
installateur ou un service d’entretien qualifié ou par
le fournisseur de gaz.
CATALYTIC FIREPLACE OWNER’S
PFS
USC
®
CATALYTIC FIREPLACE
36" WOOD BURNING OUTDOOR
FIREPLACE
OPERATION AND INSTALLATION MANUAL
These models meet the EPA Wood Burning Fireplace
Program Phase 2 emission level. NOTE: To ensure proper
replace operation, the catalyst should be replaced at a
minimum of 3 years and a maximum of 5 years.
SAVE THIS BOOK
This book is valuable. In addition to instructing you
on how to install and maintain your appliance, it also
contains information that will enable you to obtain replacement parts or accessory items when needed. Keep
it with your other important papers.
This replace is approved for use as a wood burning re-
place or for use with a vented gas log approved to ANS
Z21.60 and Z21.84 standards or for use with a vent-free gas
log heater approved to ANS Z21.11.2 standard. A INNOVA-
TIVE HEARTH PRODUCTS hood must be installed when
using a vent-free log heater (see Accessories, page 21).
This wood burning replace complies with UL127CAN/ULC-S610-M87 standard as a FACTORY BUILT
FIREPLACE.
FOR CANADA: The authority having jurisdiction (such
as the municipal building department, re department,
etc.) should be contacted before installation to determine the need to obtain a permit.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
For more information, visit www.SuperiorFireplaces.US.com
loss of life. Refer to this manual
for assistance or additional in-
formation. Consult a qualied
installer or local distributor.
IMPORTANT: Check local codes
before installing this replace.
Before beginning installation of this replace,
read these instructions through completely.
• This INNOVATIVE HEARTH PRODUCTS
fireplace and its components are safe
when installed according to this installation
manual. Unless you use IHP components,
which have been designed and tested for
the replace system, you may cause a re
hazard.
• The INNOVATIVE HEARTH PRODUCTS
warranty will be voided by and IHP disclaims any responsibility for the following
actions.
a. Modification of the fireplace, com-
ponents, doors, air inlet system and
damper control.
b. Use of any component part not manu-
factured or approved by INNOVATIVE
HEARTH PRODUCTS in combination
with an IHP replace system.
Proper installation is the most important step
in ensuring safe and continuous operation of
replace. Consult the local building codes as
to the particular requirements concerned with
the installation of all factory built replaces.
NOTICE: The firebox canopy
(hood) must not be modified
or replaced with a canopy that
may be provided with the un-
vented decorative room heater.
WARNING: Do not install a
replace insert in this box unless
the manufacturer's instructions
with the insert specically state
this replace has been tested for
use with this insert.
FOR YOUR SAFETY
• Do not store or use gasoline
or any other ammable vapors
or liquids in the vicinity of this
or any other appliance.
• Due to high temperatures, the
appliance should be located
out of trafc and away from
furniture and draperies.
• Do not place clothing or other
ammable materials on or near
the appliance.
• Never leave children unattended when a re is burning
in the replace.
WARNING: Use solid wood
or processed solid fuel re logs
only. When processed wood
fuel re logs are used, do not
poke or stir the logs while they
are burning. Use only re logs
that have been evaluated for
the application in replace and
refer to re log warnings and
caution markings on packaging
prior to use.
This replace is not intended to
be used as a substitute for a fur-
nace to heat an entire home. Use
for supplemental heat only.
SPECIFICATIONS
GAS LINE
0" TO
TOP
SPACERS
0.75"
AIR
SPACE
BACK
AND
SIDES
OUTSIDE
AIR (LEFT
SIDE ONLY)
0" TO
BOTTOM
21"
1" AIRSPACE
TO COMBUSTIBLE
MATERIAL
HEARTH
EXTENSION
8" EACH
SIDE
29"
52" X 18"
ELECTRICAL
OUTLET
NO COMBUSTIBLE
MATERIAL ON FACE
8.717"
11.217"
COMBUSTIBLE
WALL BOARD
11.435"
NOT LESS
THAN 12" TO
PERPENDICULAR
SIDEWALL
12.5"
RIGHT SIDE
7.092"
LEFT SIDE
14.437"
22"
8.717"
KNOCK
OUTS
9.125"
3.5"
AIR KIT
KNOCK OUT
GAS LINE
KNOCK
OUTS
9.125"
3.5"
14.25"
41"
35"
41"
41.250"
0.625"
37"
8"
1"
CAUTION: THE STRUCTURAL
INTEGRITY OF THE MANUFACTURED
HOME FLOOR, WALL, AND CEILING/
ROOF MUST BE MAINTAINED.
www.SuperiorFireplaces.US.com
32.5"
1"
21"
ROUND TOP TERMINATION
SQUARE CHASE-TOP
TERMINATION
WARNING: DO NOT INSTALL IN
SLEEPING ROOM OF MOBILE HOMES.
127023-01A4
FIREPLACE INSTALLATION
SELECTING LOCATION
To determine safest and most efcient location
for replace, you must take into consideration
the following guidelines:
1. Location must allow for proper clearances
(see Figures 1 and 2).
2. Consider a location where replace will
not be affected by drafts, air conditioning
ducts, windows or doors.
3. A location that avoids cutting of joists or
roof rafters will make installation easier.
4. An outside air kit is available with this
replace (see Optional Outside Air Kit on
page 7).
MINIMUM CLEARANCE TO
COMBUSTIBLES
Back and sides of replace 3/4" minimum*
Floor** 0" minimum
Perpendicular wall to opening 14" minimum
Top spacers 0" minimum
Mantel clearances see Mantels, page 6
Chimney outer pipe surface 1" minimum
* Not required at nailing anges
** See step 2 of Framing
WARNING: Do not pack required air spaces with insulation
or other materials.
Minimum/Maximum Chimney Height
Minimum height of chimney, measured from
base of replace to ue gas outlet of termination, is 14.5 feet for straight ue or a ue with
one elbow set. Maximum distance between
elbows is 6 feet. For systems with two elbow
sets, minimum height is 22 feet. Maximum
height of any system is 50 feet. This measurement includes replace, chimney sections and
height of termination assembly at level of ue
gas outlet (see Figure 19, page 12).
Minimum/Maximum Chimney Height for
Outdoor Installation
The minimum height of the chimney, measured from the base of the replace to the
ue gas outlet of the termination, is 7 1/2 feet
(minimum of 4 feet of chimney pipe sections
required for outdoor installation).
FRAMING
1. Frame opening for replace using dimensions shown in Figures 1 and 2.
2. If replace is to be installed directly on
carpeting, tile (other than ceramic) or any
combustible material other than wood
ooring, replace must be installed upon
a metal or wood panel extending full width
and depth of replace.
3. Set replace directly in front of this opening and slide unit back until nailing anges
touch side framing.
4. Check level of replace and shim with
sheet metal if necessary.
5. Before securing fireplace to prepared
framing, ember protector must be placed
between hearth extension (not included)
and under bottom front edge of replace
to protect against glowing embers falling
through. If replace is to be installed on
a raised platform, a Z-type ember protector (not included) must be fabricated to
t your required platform height. Ember
protector should extend under replace a
minimum of 1 1/2". Ember protector should
be made of galvanized sheet metal (28
gauge minimum) to prevent corrosion.
6. Using screws or nails, secure replace to
framing through anges located on sides
of replace.
41.75"
41.75"
21.875"
Figure 1 - Framing Dimensions
24.399"
17.253"
52.183"
73.798"
3
MAINTAIN
/4"
CLEARANCE AT
SIDES AND BACK
OF FIREPLACE
3
/4" CLEARANCE
NOT REQUIRED AT
NAILING FLANGES
Figure 2 - Corner Installation
127023-01A5
www.SuperiorFireplaces.US.com
FIREPLACE INSTALLATION
DRAIN PAN (DP36)
For outdoor installations, the replace enclosure must allow for adequate drainage and
fresh air ventilation. It is recommended that
a sealed, corrosion resistant catch pan with
provision for drainage be installed under the
replace within the replace enclosure (see
Accessories on page 21).
HEARTH EXTENSION
A hearth extension projecting a minimum of
16" in front of and a minimum of 8" beyond
each side of replace opening is required to
protect combustible oor construction in front
of replace. Fabricate a hearth extension
using a material which meets the following
specications: a layer of noncombustible,
inorganic material having a thermal conductivity of K=0.84 BTU IN/FT, HR. F (or less) at 1"
thick. For example, if material selected has
a K factor of 0.25, such as glass ber, the
following formula would apply:
0.25 x 1.0" = 0.30" thickness required
0.84
Thermal conductivity "K" of materials can be
obtained from manufacturer or supplier of
noncombustible material. If hearth extension
is to be covered, use noncombustible material such as tile, slate, brick, concrete, metal,
glass, marble, stone, etc. Provide a means
to prevent hearth extension from shifting and
seal gap between replace frame and hearth
extension with a noncombustible material
(see Figure 3).
WARNING: Hearth extension
is to be installed only as shown
in Figure 3.
Fireplace Front
Ember Protector
Fireplace Front
Raised Hearth
Ember Protector
Fireplace Front
Elevated
Ember Protector
Figure 3 - Hearth Extension
Seal Gap
Hearth
Extension
Seal Gap
www.SuperiorFireplaces.US.com
127023-01A6
FIREPLACE INSTALLATION
Continued
MANTELS
A mantel may be installed if desired (see
Figures 4 and 5). Woodwork such as wood
trims, mantels or any other combustible
material projecting from front face, must not
be placed within 9" of replace opening and
within 6" of top louver opening. Combustible
materials above 9" and projecting more than
1 1/2" from replace must not be placed less
than 12" from top opening of replace (NFPA
STD 211, Sec. 7-3.3.3).
12 1/4" Ref.
Combustible
Material
Mantels or any other combustible material
also may come up to the side edge of the
stainless steel face of the replace just as long
as the projection from the front face fall within
the limit shown in Figure 4 and 5.
Top View of Fireplace
FIREBOX
8.0"
33°
SAFE ZONE
2" Max.
3.0"
Safe
6"
Ref.
12" Min.
33°
3" Nom.
11/2" Max.
9" Min.
Fireplace Opening
Figure 5 - Mantel Clearances to
Combustible Material
Zone for
Projection of
Combustible
Materials
Upper
Section of
Fireplace
VENTING INSTALLATION
OPTIONAL OUTSIDE AIR KIT
(MODEL AK4/AK4F)
Installation of an outside air kit should be
performed during rough framing of replace
due to the nature of it's location. Outside combustion air is accessed through a vented crawl
space (AK4F) or through a sidewall (AK4).
See Figure 23 on page 15 for instruction of
operating air kit.
CAUTION: Combustion air
inlet ducts shall not terminate
in attic space.
Min. to
Perpendicular
Side Wall
12"
Figure 5 - Mantel Clearances to
Combustible Material
Combustible
Material Must
Not Overlap
Front Face
The maximum height for the
air vent can not exceed 3 feet
below the ue gas outlet of the
termination.
CHIMNEY PIPE
INNOVATIVE HEARTH PRODUCTS chimney
system consists of 12", 18", 24", 36" and
48" snap-lock, double-wall pipe segments,
planned for maximum adaptability to individual
site requirements. Actual lengths gained after
tting overlaps must be taken into consideration (lineal gain) and are given in lineal gain
chart (see Figure 7, page 7). Lineal gain is
actual measurable length of a part after two
or more parts are connected. For Canada, use
chimney parts designated "HT".
127023-01A7
www.SuperiorFireplaces.US.com
VENTING INSTALLATION
Continued
Secure to Collars with Metal Tape, Screws
or Straps (Min. of 1/4" x 20" in size)
Air Inlet
Location
Must Allow
For Bushes
or Snow
12 3/8"
Galvanized
Outer Pipe
8" Stainless
Inner Pipe
Hemmed
End
Air Inlet
Vented Crawl Space
(Check Local Codes
Before Installing in a
Vented Crawl Space)
Eyebrow
Vent Hood
Required for
Wall Installation
Figure 6 - Outside Air Kit
WARNING: The opening in
collar around chimney at top of
replace must not be obstructed.
Never use blown insulation to ll
chimney enclosure.
ASSEMBLY AND INSTALLATION OF
DOUBLE WALL CHIMNEY SYSTEM
Each double wall chimney section consists of
a galvanized outer pipe, a stainless steel inner ue pipe and a wire spacer. Pipe sections
must be assembled independently as chimney
is installed. When connecting chimney directly
to replace, inner ue pipe section must be
installed rst with lanced side up. Outer pipe
section can then be installed over ue pipe
section with hemmed end up. Press down
on each pipe section until lances securely
engage hem on replace starter. The wire
will assure proper spacing between inner and
outer pipe sections.
Note: For Canada, use chimney parts designated HT.
PART NO.DESCRIPTIONGAIN
36"Fireplace37 1/2"
12-8DM
12-8HT
18-8DM
18-8HT
24-8DM
24-8HT
36-8DM
36-8HT
48-8DM
48-8HT
RT-8DMRound Termination6 7/8"*
RTL-8DMRound Termination7 3/4"*
RLT-8DMRound Termination7 1/2"
RTT-8DM
RTTL-8DM
RLTT-8DM
ET-8DMSquare Chase-Top12"*
ETO-8DM
ETL-8DM
ETLO-8DM
LINEAL GAIN
Pipe Section10 5/8"
Pipe Section16 5/8"
Pipe Section23 5/8"
Pipe Section34 5/8"
Pipe Section46 5/8"
Round Termination
with Slip Section
Round Termination
with Slip Section
Round Termination
with Slip Section
Square Chase-Top
with Mesh
Square Chase-Top
with Slip Section
Square Chase-Top
with Mesh & Slip
Section
6 7/8" to
23 1/8"*
8 1/2" to
21 1/2"*
7 1/2" to
21 1/4"*
12"*
7" to 15"*
12" to
25 1/2"*
* The lineal gain for the terminations is
measured to the ue gas outlet height.
Figure 7 - Lineal Gain
Opening in collar around
chimney at top of replace must
not be obstructed. Never use
blown insulation to ll chimney
enclosure.
www.SuperiorFireplaces.US.com
127023-01A8
VENTING INSTALLATION
Continued
Continue to assemble chimney sections as
outlined, making sure that both inner and
outer pipe sections are locked together. When
installing double wall snap-lock chimney together, it is important to assure joint between
chimney sections is locked. Check by pulling
chimney upward after locking. Chimney will
not come apart if properly locked. It is not
necessary to add screws to keep chimney together (exception - see Figure 10, page 9).
USING ELBOW OFFSETS (30E-8DM)
1. To achieve desired offset, you may install
combinations of 12", 18", 24", 36" and 48"
length of double wall pipe (see offset chart
on page 9 and Figure 8).
Note: For systems with 2 elbow sets, mini-
mum height is 22 feet. Maximum height
for any system is 50 feet.
2. Chimney weight above offset rests on
return elbow. Straps must be securely
nailed to rafters or joists (see Figure 9,
details A and B on page 9).
3. Maximum length of pipe between supports
(return elbow or 12S-8DM) is 6' of angle
run. Maximum of two 6' angle run sections
per chimney system (see Figure 8).
4. All pipe connections between offset and
return must be secured with two screws
on outer pipe only (see Figure 10, page
9). Do not penetrate inner stainless.
Offset
Elbow
Return
Elbow
6' Max.
6' Max.
Return
Elbow
Offset
Elbow
Return
Elbow
Offset
Offset
Elbow
A
Elbow
Figure 8 - Typical Offset Installation
6' Max.
BC
6' Max.
Offset
Elbow
Return
Elbow
Ceiling
Support Pipe
12S-8DM
Return
Elbow
6' Max.
6' Max.
127023-01A9
www.SuperiorFireplaces.US.com
Loading...
+ 19 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.