WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property
damage. Refer to this manual for correct installation and
operational procedures. For assistance or additional
information consult a qualifi ed installer, service agency
or the gas supplier.
This appliance may be installed
in an aftermarket,* permanently
located, manufactured (mobile)
home, where not prohibited by
local codes.
* Aftermarket: Completion of sale, not for
purpose of resale, from the manufacturer
This fi rebox has been tested
under Z21.91b-2007 for use with
approved ANSI Z21.1 1.2 decorative type unvented room heater .
WARNING: Any change to
this heater or its controls can
be dangerous.”
WARNING: Do not use a
blower insert, heat exchanger
insert or other accessory not approved for use with this fi rebox.
IMPORT ANT: Read this owner’s
manual carefully and completely
before trying to assemble, operate or service this fi replace.
Improper use of this fi replace
can cause serious injury or death
from burns, fire, explosion,
electrical shock and carbon
monoxide poisoning.
DANGER: Carbon monoxide
poisoning may lead to death!
WARNING: Do not allow fans
to blow directly into the fi rebox.
Avoid any drafts that alter burner
fl ame patterns. Ceiling fans can
create drafts that alter burner
fl ame patterns. Altered burner
patterns can cause sooting.
W ARNING: If the information
in this manual is not followed
exactly, a fi re or explosion may
result causing property damage,
personal injury or loss of live
SuperiorFireplaces.US.com
Due to high temperatures, the
appliance should be located out
of traffi c and away from furniture
and draperies.
126700-01B2
SAFETY
Continued
Do not place clothing or other
fl ammable material on or near
the appliance. Never place any
objects in the fi rebox or on logs.
Firebox front and screen becomes very hot when running
fi rebox. Keep children and adults
away from hot surfaces to avoid
burns or clothing ignition. Firebox will remain hot for a time
after shutdown. Allow surfaces
to cool before touching.
Keep the fi replace area clear and
free from combustible materials,
gasoline, and other fl ammable
vapors and liquids.
You must operate this fi replace
with the provided fireplace
screen and hood in place. Make
sure these parts are in place
and screens are closed before
running installed gas log heater.
Replace hood with INNOV ATIVE
HEARTH PRODUCTS cat. no.
J4350 - 50", cat. no. J4351 - 42",
or cat. no. J4352 - 36" only . This
hood has been designed to keep
the operation of your fi replace
safe and effi cient.
1. Do not use this fi rebox as a wood burning
fi replace. Use only decorative unvented
room heaters (log sets).
2. Do not add extra logs or ornaments such as
pine cones, vermiculite or rock wool. Using
these added items can cause sooting.
3. Use only the provided hood. See Parts, Page 18. The firebox canopy (hood)
must not be modifi ed or replaced with a
canopy (hood) that may be provided with
the unvented decorative room heater.
4. Vent-free gas log heaters installed in these
fi reboxes require fresh air ventilation to
run properly . See Air for Combustion and Ventilation, Page 8.
5. Do not run vent-free heaters installed in
these fi reboxes
• where fl ammable liquids or vapors are
used or stored
• under dusty conditions
6. Do not use this fi rebox to cook food or
burn paper or other objects.
7. Turn unit off and let cool before servicing.
Only a qualifi ed service person should
service and repair fi rebox.
8. Operating vent-free heaters installed in
these fi reboxes above elevations of 4,500
feet could cause pilot outage.
9. Do not use the fi rebox if it has been
under water.
10. Before using furniture polish, wax, carpet
cleaner or similar products, turn heater
off. If heated, the vapors from these products may create a white powder residue
within burner box or on adjacent walls
and furniture.
11. Provide adequate clearances around air
openings.
Children and adults should be
alerted to the hazard of high
surface temperature and should
stay away to avoid burns or
clothing ignition.
Y oung children should be carefully supervised when they are
in the same room with the appliance.
126700-01B3
SuperiorFireplaces.US.com
LOCAL CODES
Install and use fi rebox with care. Follow all
local codes. In the absence of local codes,
use the latest edition of The National Fuel
Gas Code ANSI Z223.1/NFPA 54*; National
Fuel Gas Code (latest edition). Firebox must
be electrically grounded in accordance with
the National Electrical Code, ANSI/NFPA 70
(latest edition).
*Available from:
American National Standards Institute, Inc.
25 West 43rd Street, 4th fl oor
New York, NY 10036
National Fire Protection Association, Inc.
1 Batterymarch Park
Quincy, MA 02169-7471
COMMONWEALTH OF MASSACHUSETTS REQUIREMENTS
These appliances are approved for installation in the US state of Massachusetts if the
following additional requirements are met:
• Un-vented Room Heaters shall be installed in accordance with 527 CMR 30.
• Installation and repair must be done by
a plumber or gas fi tter licensed in the
Commonwealth of Massachusetts.
• The fl exible gas line connector used shall
not exceed 36 inches (92 centimeters)
in length.
• The individual manual shut-off must be
a T-handle type valve.
• Unvented appliances may NOT be installed in bedrooms or bathrooms.
• A working smoke detector must be
installed in the area where vent-free appliances are installed.
Seller of unvented propane or natural
gas-fi red supplemental room heaters shall
provide to each purchaser a copy of 527
CMR 30 upon sale of the unit.
LOCATING FIREBOX
PLANNING
Plan where you will install the fi rebox. This will
save time and money later when you install
the fi rebox. Before installation, consider the
following:
1. Where fi rebox will be located. Allow for
wall and ceiling clearances (see Installa-
tion Clearances, Page 11).
2. Everything needed to complete installation.
3. These models CANNOT be installed in
a bedroom unless maximum Btu rating
of installed vent-free log set is less than
10,000 Btu/hr.
4. Proper air for combustion and ventilation
(Page 8).
PRODUCT FEATURES
OPERATION
This fi rebox is designed for use with approved
ANSI Z21.1 1.2 decorative type unvented room
heaters. (Physical size limitations apply . Refer
to minimum fi rebox requirements supplied
with log heater.) It requires no outside venting or chimney making installation easy and
inexpensive.
SuperiorFireplaces.US.com
126700-01B4
36" MODELS
PRODUCT SPECIFICATIONS
54
30 1/2"
11
1
/2"
30"
7
7
1
/8"
29"
7
4
/8"
3
/4"
3
22 1/2"
1
/4"
35
36" HEARTH
19"
20
(Ref.)
1
1
/4"
1
/4"
/8"
50"
3
/8"
36
7"
36"
1
45
/8"
1
/2"
9
3
/8"
3
3
7
/8"
1
11
/8"
Figure 1 - 36" Models VRT4536WS and VRT4536WH
(Picture may vary from actual fi replace)
126700-01B5
SuperiorFireplaces.US.com
42" MODELS
PRODUCT SPECIFICATIONS
Continued
54 1/2"
11
7
32
30"
7
1
/8"
/8"
3
/8"
30
26 3/8"
23"
3
21
/4"
1
(Ref.)
1
/4"
3
/8"
3
/8"
3
4 7/8"
3
/4"
41
42" HEARTH
50"
3
/8"
36
1
9
7"
42"
1
51
/8"
/2"
3
/8"
3
3
8
/4"
13"
Figure 2 - 42" Models VRT4542WS and VRT4542WH
(Picture may vary from actual fi replace)
SuperiorFireplaces.US.com
126700-01B6
50" MODELS
PRODUCT SPECIFICATIONS
Continued
54
3
38
/8"
34 3/8"
23"
3
/4"
3
32
/8"
7
/8"
4
3
/4"
3
1
11
/8"
1
/2"
30"
50"
3
49
/8"
50" HEARTH
21
1
(Ref.)
1
/4"
363/8"
7
7
/8"
7"
50"
1
/8"
59
1
9
/2"
3
3
/8"
3
/4"
8
13"
Figure 3 - 50" Models VRT4550WS and VRT4550WH
(Picture may vary from actual fi replace)
126700-01B7
SuperiorFireplaces.US.com
AIR FOR COMBUSTION AND VENTILATION
WARNING: This heater shall not
be installed in a room or space unless the required volume of indoor
combustion air is provided by the
method described in the National
Fuel Gas Code, ANSI Z223.1/NFP A
54, the International Fuel Gas
Code, or applicable local codes.
Read the following instructions
to ensure proper fresh air for this
and other fuel-burning appliances
in your home.
Today’s homes are built more energy effi cient
than ever. New materials, increased insulation
and new construction methods help reduce heat
loss in homes. Homeowners apply weather strip
and caulk around windows and doors to keep
the cold air out and the warm air in. During heating months, homeowners want their homes as
airtight as possible.
While it is good to make your home energy
effi cient, your home needs to breathe. Fresh
air must enter your home. All fuel-burning appliances need fresh air for proper combustion
and ventilation.
Exhaust fans, some fi replaces, clothes dryers
and some fuel-burning appliances draw air from
the house to operate. Y ou must provide adequate
fresh air for these appliances. This will ensure
proper venting of vented fuel-burning appliances.
PROVIDING ADEQUA TE VENTILA TION
The following are excerpts from National Fuel
Gas Code, ANSI Z223.1/NFPA 54, Air for Combustion and Ventilation.
All spaces in homes fall into one of the three
following ventilation classifi cations:
1. Unusually Tight Construction
2. Unconfi ned Space
3. Confi ned Space
The information on Pages 8 through 10 will help
you classify your space and provide adequate
ventilation.
Unusually Tight Construction
The air that leaks around doors and windows
may provide enough fresh air for combustion and
ventilation. However, in buildings of unusually
tight construction, you must provide additional
fresh air.
SuperiorFireplaces.US.com
Unusually tight construction is defi ned as
construction where:
a. walls and ceilings exposed to the outside
atmosphere have a continuous water
vapor retarder with a rating of one perm
(6 x 10
openings gasketed or sealed and
b. weather stripping has been added on
openable windows and doors and
c. caulking or sealants are applied to areas
such as joints around window and door
frames, between sole plates and fl oors,
between wall-ceiling joints, between
wall panels, at penetrations for plumbing, electrical and gas lines and at other
openings.
If your home meets all of the three criteria
above, you must provide additional fresh air.
See Ventilation Air From Outdoors, Page 10.
If your home does not meet all of the three
criteria above, proceed to Determining Fresh-Air Flow For Firebox Location.
Confi ned and Unconfi ned Space
The National Fuel Gas Code, ANSI Z223.1/
NFPA54 allows two methods for determining
whether the space in which the heater is being
installed is confi ned or unconfi ned space. The
standard method defi nes a confi ned space as a
space whose volume is less than 50 cubic feet
per 1,000 Btu per hour (4.8 m
gregate input rating of all appliances installed in
that space and an unconfi ned space as a space
whose volume is not less than 50 cubic feet per
1,000 Btu per hour (4.8 m
gregate input rating of all appliances installed in
that space. Rooms communicating directly with
the space in which the appliances are installed*,
through openings not furnished with doors, are
considered a part of the unconfi ned space.
Where the air infi ltration rate of a structure is
known, the Known Air Infi ltration Rate Method
may be used. Follow The National Fuel Gas
Code, ANSI Z223.1/NFPA 54 to use this
method to determine if the space is confi ned
or unconfi ned.
* Adjoining rooms are communicating only if
there are doorless passageways or ventilation
grills between them.
-11
kg per pa-sec-m2) or less with
3
per kw) of the ag-
3
per kw) of the ag-
DETERMINING FRESH-AIR FLOW FOR
HEATER LOCATION
Determining if You Have a Confi ned or
Unconfi ned Space Using the Standard
Method
126700-01B8