Superior VRT4032ZMN, VRT4036ZMN, VRT4032ZMP, VRT4036ZMP Installation And Operation Instructions Manual

Installation and Operation Instructions
Superior™ Radiant Faced Fireplace System with Logs and Thermostat Blower
P/N 126868-01 Rev.A 02/2014 Models
VRT4032ZMN VRT4032ZMP VRT4036ZMN VRT4036ZMP
P126868-01
INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.
This appliance may be installed in an aftermarket permanently located, manufactured (mobile) home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.
This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed. Provisions for adequate combustion and ventilation air must be provided. Refer to Air for Combustion and Ventilation section on page 6 of this manual.
causing property damage, personal injury or loss of life.
— Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other
appliance.
— WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.
— Installation and service must be performed by a qualified installer, service agency or the gas supplier.
TABLE OF CONTENTS
Safety .................................................................. 2
Product Identication ........................................... 4
Local Codes......................................................... 5
Unpacking............................................................ 5
Product Features ................................................. 5
Air For Combustion and Ventilation ..................... 6
Installation ........................................................... 8
Operation ........................................................... 21
Inspecting Burners............................................. 23
Cleaning and Maintenance ................................ 24
Troubleshooting ................................................. 25
Wiring Diagram .................................................. 29
Specications .................................................... 29
Replacement Parts ............................................ 29
Service Hints ..................................................... 29
Technical Service............................................... 29
Parts .................................................................. 30
Accessories ....................................................... 35
Warranty ............................................................ 36
WARNING: Improper instal­lation, adjustment, alteration, service, or maintenance can cause injury or property damage. Refer to this manual for correct installation and operational procedures. For assistance or additional information consult a qualified installer, service agency, or the gas supplier.
WARNING: This is an un-
vented gas-red heater. It uses
air (oxygen) from the room in which it is installed. Provisions for adequate combustion and ventilation air must be provided. Refer to Air for Combustion and Ventilation section on page 6 of this manual.
This appliance may be installed in an aftermarket,* permanently located, manufactured (mobile) home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.
* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer
WARNING: This product con­tains and/or generates chemicals known to the state of California to cause cancer or birth defects, or other reproductive harm.
IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, operate,
or service this replace. Improper use of this replace can cause
serious injury or death from burns,
re, explosion, electrical shock,
and carbon monoxide poisoning.
DANGER: Carbon monoxide poisoning may lead to death!
Carbon Monoxide Poisoning: Early signs
of carbon monoxide poisoning resemble the
u, with headaches, dizziness, or nausea. If you have these signs, the replace may not be working properly. Get fresh air at once! Have replace serviced. Some people are
more affected by carbon monoxide than oth-
ers. These include pregnant women, people with heart or lung disease or anemia, those under the inuence of alcohol, and those at
high altitudes. Natural and Propane/LP Gas: Natural and
propane/LP gases are odorless. An odor­making agent is added to these gases. The
odor helps you detect a gas leak. However, the odor added to the gas can fade. Gas may
be present even though no odor exists. Make certain you read and understand all
warnings. Keep this manual for reference. It
is your guide to safe and proper operation of
this replace.
www.SuperiorFireplaces.US.com
126868-01A2
SAFETY
Continued
WARNING: Any change to this heater or its controls can be dangerous.
WARNING: Do not allow fans
to blow directly into the replace.
Avoid any drafts that alter burner
ame patterns. Ceiling fans can
create drafts that alter burner
ame patterns. Altered burner
patterns can cause sooting.
WARNING: Do not use a blower insert, heat exchanger insert, or other accessory not ap-
proved for use with this replace.
Due to high temperatures, the appliance should be located out
of trafc and away from furniture
and draperies.
Do not place clothing or other
ammable material on or near
the appliance. Never place any
objects in the replace.
Fireplace front and screen be­come very hot when running fireplace. Keep children and adults away from hot surfaces to avoid burns or clothing igni­tion. Fireplace will remain hot for a time after shutdown. Allow surfaces to cool before touching.
Carefully supervise young chil­dren when they are in the room
with replace.
You must operate this replace with the replace screen and hood in place. Make sure re-
place screen is in place before
running replace.
126868-01A 3
www.SuperiorFireplaces.US.com
Keep the appliance area clear and free from combustible materials, gasoline, and other
ammable vapors and liquids.
1. This appliance is only for use with type of
gas indicated on rating plate. This appli-
ance is not convertible for use with other
gases.
2. Do not place propane/LP supply tank(s) inside any structure. Locate propane/ LP supply tank(s) outdoors (propane/LP only).
3. If you smell gas
• shut off gas supply
• do not try to light any appliance
• do not touch any electrical switch; do not
use any phone in your building
• immediately call your gas supplier from
a neighbor’s phone. Follow the gas sup-
plier’s instructions
• if you cannot reach your gas supplier,
call the re department
4. This replace shall not be installed in a
bedroom or bathroom.
5. Do not use this replace as a wood-burn­ing replace. Use only the logs provided with the replace.
6. Do not add extra logs or ornaments such
as pine cones, vermiculite, or rock wool.
Using these added items can cause soot­ing. Do not add lava rock around base. Rock and debris could fall into the control
area of replace.
7. This replace is designed to be smoke­less. If logs ever appear to smoke, turn off replace and call a qualied service
person.
Note: During initial operation, slight smok-
ing could occur due to log curing and
replace burning manufacturing residues.
8. To prevent the creation of soot, follow the
instructions in Cleaning and Maintenance, page 23.
9. Before using furniture polish, wax, carpet cleaner, or similar products, turn heater off. If heated, the vapors from these prod­ucts may create a white powder residue within burner box or on adjacent walls or
furniture.
SAFETY
Continued
10. This replace needs fresh air ventilation to run properly. This replace has an Oxygen
Depletion Sensing (ODS) safety shutoff system. The ODS shuts down the re­place if not enough fresh air is available. See Air for Combustion and Ventilation,
page 6. If replace keeps shutting off, see Troubleshooting, page 24.
11. Do not run replace
• where ammable liquids or vapors are
used or stored.
• under dusty conditions.
12. Do not use this replace to cook food or burn paper or other objects.
13. Do not use replace if any part has been under water. Immediately call a qualied
service technician to inspect the room
replace and to replace any part of the control system and any gas control which has been under water.
14. Turn off and unplug fireplace and let
cool before servicing. Only a qualied
service person should service and repair
replace.
15. Operating replace above elevations of 4,500 feet could cause pilot outage.
16. Do not operate fireplace if any log is
broken. Do not operate replace if a log is chipped (dime-sized or larger).
17. To prevent performance problems, do not
use propane/LP fuel tank of less than 100 lbs. capacity (propane/LP only).
18. Provide adequate clearances around air
openings.
19. The screen or any other part removed for servicing must be replaced prior to operating this heater.
PRODUCT
IDENTIFICATION
Log Set
Front Burner
Figure 1 - Log Base Assembly
Left Side
Top panel Assembly
Fireplace Hood
Magnet
Base Assembly
Screen Assembly
www.SuperiorFireplaces.US.com
Top Outer Casing
Bottom Panel Assembly
Front
Figure 2 - Fireplace
Right Side
126868-01A4
LOCAL CODES
Install and use replace with care. Follow all local codes. In the absence of local codes,
use the latest edition of The National Fuel
Gas Code ANSI Z223.1/NFPA 54*.
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
Note: Where listed vented decorative logs are required, thermostat operation is not
permitted.
UNPACKING
CAUTION: Do not remove the data plates attached to the heater base assembly. The data plates contain important warranty and safety information.
1. With utility knife, cut the carton all the way
around above the staples on the bottom tray. Lift the carton off the heater. Remove packing.
Note: The hood is located in the packing
on the right hand side of the heater front. Lift the heater off the bottom tray.
State of Massachusetts: The installation must be made by a licensed plumber or gas tter in the Commonwealth of Mas­sachusetts.
Sellers of unvented propane or natural
gas-red supplemental room heaters shall
provide to each purchaser a copy of 527 CMR 30 upon sale of the unit.
Vent-free gas products are prohibited for bedroom and bathroom installation in the
Commonwealth of Massachusetts.
2. Locate two screws above top corners of the replace screen. Remove and discard these screws. Push the bottom corners of the screen in and release. The screen will pop out at the bottom. Grasp the bottom of the screen, lift the screen up and pull
out to remove.
3. Remove protective packaging applied to
logs, log base assembly, and replace.
4. Remove fireplace hood from carton inserts.
5. Check all items for any shipping damage.
If damaged, promptly inform dealer where you bought replace.
PRODUCT FEATURES
OPERATION
This vent-free replace is clean burning. It requires no outside venting. There is no heat
loss out a vent or up a chimney. Heat is gen-
erated by both realistic ames and glowing embers. When used without the blower, the replace requires no electricity making it ideal
for emergency backup heat.
SAFETY DEVICE
This replace has a pilot with an Oxygen
Depletion Sensing (ODS) safety shutoff
system. The ODS/pilot is a required feature
for vent-free room heaters. The ODS/pilot
system shuts off the replace if there is not
enough fresh air.
PIEZO IGNITION SYSTEM
This replace has a piezo ignitor. This sys­tem requires no matches, batteries, or other sources to light replace.
126868-01A 5
www.SuperiorFireplaces.US.com
OPTIONAL REMOTE CONTROL ACCESSORY
There are ve optional remote controls (not
included) that can be purchased separately for this log heater:
• wall switch
• wall thermostat
• hand-held ON/OFF remote
• hand-held thermostat remote
• TSRC hand-held remote
See Accessories, page 35.
BLOWER ASSEMBLY ACCESSORY
This replace includes a blower assembly. The blower operates thermostatically and features a variable speed control. The blower circulates
heated air from the replace into the room.
AIR FOR COMBUSTION AND VENTILATION
WARNING: This heater shall not be installed in a room or space unless the required vol­ume of indoor combustion air is provided by the method de­scribed in the National Fuel Gas
Code, ANSI Z223.1/NFPA 54, the International Fuel Gas Code, or
applicable local codes. Read the following instructions to insure proper fresh air for this and other fuel-burning appliances in your home.
Today’s homes are built more energy efcient than ever. New materials, increased insulation, and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in. Dur­ing heating months, home owners want their
homes as airtight as possible. While it is good to make your home energy
efcient, your home needs to breathe. Fresh
air must enter your home. All fuel-burning ap­pliances need fresh air for proper combustion and ventilation.
Exhaust fans, replaces, clothes dryers, and fuel burning appliances draw air from the house to operate. You must provide adequate fresh air for these appliances. This will insure proper
venting of vented fuel-burning appliances.
PROVIDING ADEQUATE VENTILATION
The following are excerpts from National Fuel
Gas Code, ANSI Z223.1/NFPA 54, Air for Combustion and Ventilation.
All spaces in homes fall into one of the three
following ventilation classications:
1. Unusually Tight Construction
2. Unconned Space
3. Conned Space The information on pages 6 through 8 will help
you classify your space and provide adequate
ventilation.
Unusually Tight Construction
The air that leaks around doors and windows
may provide enough fresh air for combustion
and ventilation. However, in buildings of un­usually tight construction, you must provide
additional fresh air.
Unusually tight construction is dened as
construction where: a. walls and ceilings exposed to the out-
side atmosphere have a continuous water vapor retarder with a rating of one perm (6 x 10 with openings gasketed or sealed and
b. weather stripping has been added on
openable windows and doors and
c. caulking or sealants are applied to
areas such as joints around window and door frames, between sole plates
and oors, between wall-ceiling joints,
between wall panels, at penetrations for plumbing, electrical, and gas lines, and at other openings.
If your home meets all of the three criteria above, you must provide additional fresh air. See Ventilation Air From Outdoors, page 8.
If your home does not meet all of the three criteria above, proceed to Determining Fresh-Air Flow For Heater Location.
Conned and Unconned Space
The National Fuel Gas Code, ANSI Z223.1/ NFPA 54 denes a conned space as a space
whose volume is less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the ag-
gregate input rating of all appliances installed in
that space and an unconned space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8 m3 per kw) of the ag-
gregate input rating of all appliances installed in
that space. Rooms communicating directly with the space in which the appliances are installed*, through openings not furnished with doors, are considered a part of the unconned space.
* Adjoining rooms are communicating only if there are doorless passageways or ventilation grills between them.
-11
kg per pa-sec-m2) or less
DETERMINING FRESH-AIR FLOW FOR FIREPLACE LOCATION
Determining if You Have a Conned or Unconned Space
Use this work sheet to determine if you have a conned or unconned space.
Space: Includes the room in which you will install replace plus any adjoining rooms with door­less passageways or ventilation grills between
www.SuperiorFireplaces.US.com
126868-01A6
Or
Remove Door into Adjoining
Room, Option
3
Ventilation Grills
Into Adjoining Room,
Option 2
Ventilation
Grills Into
Adjoining
Room,
Option 1
12"
12"
AIR FOR COMBUSTION AND VENTILATION
Continued
the rooms.
1. Determine the volume of the space (length
x width x height).
Length x Width x Height =__________cu. ft.
(volume of space)
Example: Space size 20 ft. (length) x 16 ft.
(width) x 8 ft. (ceiling height) = 2,560 cu. ft.
(volume of space)
If additional ventilation to adjoining room
is supplied with grills or openings, add the
volume of these rooms to the total volume of the space.
2. Multiply the space volume by 20 to determine the maximum Btu/Hr the space can support.
________ (volume of space) x 20 = (Maxi-
mum Btu/Hr the space can support)
Example: 2,560 cu. ft. (volume of space) x
20 = 51,200 (maximum Btu/Hr the space can
support)
3. Add the Btu/Hr of all fuel burning appliances in the space.
Vent-free replace _________ Btu/Hr Gas water heater* _________ Btu/Hr Gas furnace _________ Btu/Hr
Vented gas heater _________ Btu/Hr Gas replace logs _________ Btu/Hr Other gas appliances* +________ Btu/Hr Total = ________ Btu/Hr * Do not include direct-vent gas appliances.
Direct-vent draws combustion air from the
outdoors and vents to the outdoors.
40,000 33,000 73,000
Example:
Gas water heater _____________ Btu/Hr Vent-free replace + ___________ Btu/Hr
Total = ____________ Btu/Hr
4. Compare the maximum Btu/Hr the space
can support with the actual amount of Btu/
Hr used.
_______ Btu/Hr (maximum the space can
support)
_______ Btu/Hr (actual amount of Btu/Hr
used)
Example: 51,200 Btu/Hr (maximum the
space can support)
73,000 Btu/Hr (actual amount of
Btu/Hr used)
The space in the example is a conned space
because the actual Btu/Hr used is more than the
maximum Btu/Hr the space can support. You must provide additional fresh air. Your options are as follows:
A. Rework worksheet, adding the space of an
adjoining room. If the extra space provides an unconned space, remove door to adjoining room or add ventilation grills between rooms.
See Ventilation Air From Inside Building.
126868-01A 7
www.SuperiorFireplaces.US.com
B. Vent room directly to the outdoors. See
Ventilation Air From Outdoors page 8.
C. Install a lower Btu/Hr replace, if lower Btu/
Hr size makes room unconned.
If the actual Btu/Hr used is less than the maxi-
mum Btu/Hr the space can support, the space is an unconned space. You will need no additional
fresh air ventilation.
WARNING: If the area in which the heater may be operated does not meet the required volume for indoor combustion air, combus­tion and ventilation air shall be provided by one of the methods described in the National Fuel
Gas Code, ANSI Z223.1/NFPA 54, the International Fuel Gas Code, or applicable local codes.
VENTILATION AIR
Ventilation Air From Inside Building
This fresh air would come from an adjoining unconned space. When ventilating to an adjoining unconned space, you must provide two permanent openings: one within 12" of the ceiling and one within 12" of the oor on the wall connecting the two spaces (see options 1 and 2, Figure 3). You can also remove door into adjoining room (see option 3, Figure 3).
Figure 3 - Ventilation Air from Inside
Building
Outlet Air
Ventilated Attic
Outlet A
ir
Inlet Air
Inlet Air
Ventilated
Crawl Space
To
Crawl
Space
To Attic
AIR FOR COMBUSTION AND VENTILATION
Continued
Follow the National Fuel Gas Code, ANSI
Z223.1/NFPA 54, Air for Combustion and Ventilation for required size of ventilation
grills or ducts.
Ventilation Air From Outdoors
Provide extra fresh air by using ventilation
grills or ducts. You must provide two perma­nent openings: one within 12" of the ceiling and one within 12" of the oor. Connect these
items directly to the outdoors or spaces open to the outdoors. These spaces include attics
and crawl spaces. Follow the National Fuel
Gas Code, ANSI Z223.1/NFPA 54, Air for Combustion and Ventilation for required size
of ventilation grills or ducts.
INSTALLATION
NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your primary heating system. Do not install this heater as your pri­mary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circulate the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.
WARNING: A qualied ser-
vice person must install re-
place. Follow all local codes.
WARNING: Never install the
replace
• in a bedroom or bathroom
• in a recreational vehicle
• where curtains, furniture, clothing, or other ammable
objects are less than 36" from the front and 42" from the top
• in high trafc areas
• in windy or drafty areas
of replace. For side clear-
ances see Figure 8, page 10
www.SuperiorFireplaces.US.com
Figure 4 - Ventilation Air from Outdoors
CAUTION: This replace cre­ates warm air currents. These currents move heat to wall sur-
faces next to replace. Installing replace next to vinyl or cloth
wall coverings or operating heater where impurities (such as, but not limited, to tobacco smoke, aromatic candles, clean-
ing uids, oil or kerosene lamps,
etc.) in the air exist, may discolor walls or cause odors.
Note: Your replace is designed to be used in zero clearance installations. Wall or framing material can be placed directly against any exterior surface on the rear, sides, or top of your replace, except where standoff spac­ers are integrally attached. Where standoff spacers are attached to your fireplace, combustible material (studs and wall board) may be place on top and above the top of the standoffs.
Use the dimensions shown for rough openings
to create the easiest installation. See Built-In Fireplace Installation, page 11.
IMPORTANT: Vent-free heaters add moisture
to the air. Although this is benecial, installing replace in rooms without enough ventilation air may cause mildew to form from too much
moisture. See Air for Combustion and Ventila- tion, page 6.
IMPORTANT: Make sure the replace is level. If replace is not level, log set will not work properly.
126868-01A8
INSTALLATION
Continued
CHECK GAS TYPE
Use the correct gas type (natural or propane/
LP) for your replace. If your gas supply is not correct, do not install replace. Call dealer where you bought replace for proper type replace.
WARNING: This appliance is equipped for natural or propane/ LP gas but not both. Gas type is indicated on rating plate. Field conversion is not permitted.
ELECTRICAL HOOKUP
This replace includes a blower which must be connected to either a wall receptacle or the electrical receptacle that is included within the replace. If the receptacle included with the replace is to be used, it must be wired to a 120 volt supply by a certied electrician.
INSTALLING HOOD
Install hood to rail already installed in replace as shown in Figure 5. Use 3 Phillips screws
provided.
3. Align shim under adjusting plate as shown
in Figure 6.
4. Slide one end of adjusting plate/shim
in slot on mitered edge of top trim (see Figure 6).
5. Slide other end of adjusting plate/shim
in slot on mitered edge of side trim (see Figure 6).
6. While firmly holding edges of trim to-
gether, tighten both set screws on the adjusting plate with slotted screwdriver.
7. Repeat steps 1 through 6 for other side.
8. Tighten trim hanging screws (#10 x 6.25
shoulder) into holes in cabinets. Place
the assembled trim onto replace cabinet. Align hanging notches on trim with hang­ing screws on side of replace (see Figure
7). Push trim rmly into place, sliding hanging notches over hanging screws.
Set Screws
Top Trim
Side Trim
Adjusting
Plate
Hood
Screw
Rail
Figure 5 - Installing Hood
Mitered
Slot
Edge
Figure 6 - Assembling Perimeter Trim
Shim
Mitered Edge
Slot
Trim Hanging
Screws
ASSEMBLING AND ATTACHING OPTIONAL PERIMETER TRIM
IMPORTANT: If you are recessing the rebox in a wall, do not attach trim at this time. See
Built-In Fireplace Installation, page 11. Note: These instructions show assembling and attaching trim to replace.
1. Remove packaging from three pieces of trim.
2. Locate four screws, two adjusting plates with set screws, and two shims in the hardware packet.
126868-01A 9
www.SuperiorFireplaces.US.com
Assembled Trim
Figure 7 - Attaching Perimeter Trim to
Fireplace
Hanging Notches on Trim
INSTALLATION
Continued
INSTALLATION CLEARANCES
WARNING: Maintain the minimum clearances. If you can, provide greater clearances from
oor, ceiling, and adjoining wall.
Carefully follow the instructions below. This will ensure safe installation.
Minimum Clearances For Side Combustible Material, Side Wall, and Ceiling
A. Clearances from the side of the replace
cabinet to any combustible material and
wall should follow diagram in Figure 8.
Example: The face of a mantel, bookshelf,
etc. is made of combustible material and protrudes 3 1/2" from the wall. This com-
bustible material must be 4" from the side of the replace opening (see Figure 8).
B. Clearances from top of replace opening
to ceiling should not be less than 42".
MINIMUM CLEARANCE TO
COMBUSTIBLE MATERIALS
Top 0", Left and Right Sides 16",
Bottom and Rear 0", Front 36"
Example
*
*Minimum 16" from Side Wall
Figure 8 - Minimum Clearance for
Combustible to Wall
CONVENTIONAL FIREPLACE INSTALLATION
Conventional installation of this fireplace
involves installing replace along with the corner, face, or cabinet mantel with hearth base accessories against a wall in your home. Follow the instructions in this section to install the replace in this manner.
1. Assemble cabinet mantel, hearth base,
and trim accessories. Assembly instruc-
tions are included with each accessory.
www.SuperiorFireplaces.US.com
2. Install a properly grounded, 120 volt three­prong electrical outlet at replace location if an outlet is not there. If possible, locate outlet so cabinet mantel will cover it when
installed (see Figure 9).
3. Install gas piping to replace location. This installation includes an approved exible gas line (if allowed by local codes) after the equipment shutoff valve. The exible
gas line must be the last item installed on the gas piping. See Installing Gas Piping to Fireplace Location, page 13.
4. Place hearth base accessory against wall at
installation location. Cut an access hole in
hearth top to run exible gas line to replace
(see Figure 9). Make sure to locate access
hole so cabinet mantel will cover it when
installed.
Note: You can secure base to oor using
wood screws. Countersink screw heads and putty over.
5. Route exible gas line through access
hole in hearth base.
6. Center cabinet mantel on hearth base (see
Figure 10, page 11). Make sure mantel is ush against wall.
7. Place cardboard or other protective mate­rial on top of hearth base. Carefully set
replace on protective material, with back of replace inside mantel opening.
8. Attach exible gas line from replace gas
regulator to gas supply. See Connecting Fireplace to Gas Supply, page 14.
9. Route blower electrical cord through ac­cess holes in either side of replace.
Electrical Outlet
Rigid Pipe and Gas
Shutoff Valve
Hearth Base
Figure 9 - Placing Hearth Base
Accessory Against Wall
Gas Line
Access Hole
126868-01A10
INSTALLATION
Depth
(Minimum)
Width
(Inside to Inside)
Height
Continued
10. Carefully insert replace into cabinet mantel.
Be careful not to scratch or damage hearth
base, cabinet mantel, or any laminate trim
on hearth base. Remove protective material from top of hearth base and from front of
replace (if any).
Note: You can secure replace to hearth
or oor. Remove burner assembly. Locate screw holes in bottom of base. Tighten wood screws through these holes and into hearth or oor. Replace burner assembly.
11. Check all gas connections for leaks. See Checking Gas Connections, page 15.
Cabinet Mantel
Figure 12 - Inserting Fireplace Into
Cabinet Mantel
BUILT-IN FIREPLACE INSTALLATION
Built-in installation of this replace involves installing replace into a framed-in enclosure. This makes the front of replace ush with wall. If installing a mantel above the replace, you must follow the clearances shown in Figure 16, page 12. Follow the instructions below to install the replace in this manner.
Rough Opening Dimensions for Built-in
Installation
Model
Front Width
(Inside to Inside)
Height Depth
32" 34 7/8" 36 3/4" 16 1/4"
Figure 10 - Installing Cabinet Mantel
36" 41 1/2" 40 1/2" 20 3/4"
1. Frame in rough opening. Use dimensions
shown in Figure 13 for the rough opening. If installing in a corner, use dimensions shown in Figure 14, Figure 12, for the
rough opening.
Nailing Flange
Figure 11 - Location of Nailing Flange
126868-01A 11
www.SuperiorFireplaces.US.com
Figure 13 - Rough Opening for Installing
in Wall
INSTALLATION
Supplied Firebox Hood Must Be Used at All Times
Wire-mesh Screen
Firebox
Noncombustible Material May Project Off this Surface above the Firebox Hood
Mantel Shelf
Note: Any portion of the mantel shelf must NOT extend beyond this profile.
12" 16" 20"
1
1
/
2
"
6
3
/
4
"
12"
Note: All vertical measurements are from top of fireplace hood opening to bottom of mantel shelf. These minimum clearances replace any other recommended clearances supplied with your ANSI Z21.11.2 approved gas logs.
Wall board or facing material (above firebox) may be of combustible material, including decorative mantel ornaments or other similar projec­tions off of the facing material.
Framing Material
Continued
2. Install gas piping into replace location. This installation includes an approved ex­ible gas line (if allowed by local codes) after the equipment shutoff valve. The exible
gas line must be the last item installed on the gas piping. See Installing Gas Piping
to Fireplace Location, page 13.
3. Carefully set replace in front of rough opening with back of replace inside wall
opening.
4. Carefully insert fireplace into rough opening.
5. Attach exible gas line to gas supply.
See Connecting Fireplace to Gas Supply, page 14.
6. Attach replace to wall studs using nails or wood screws through holes in nailing ange (see Figure 15).
FOR 32" MODELS
Figure
39
a
1
*10
/2"
FOR 36" MODELS
Figure
50
3
/8"
b
3
/8"
34
55 5/8"
1
/2"
0" CLEARANCE
3
/4"
27
1
*10
/2"
0" CLEARANCE
5
35
/8"
7. Check all gas connections for leaks. See
Checking Gas Connections, page 15.
8. Plug electrical cord into electrical outlet installed in step 2.
9. Install trim after nal nishing and/or paint­ing of wall (see Figure 7, page 9).
IMPORTANT: When nishing your rebox, combustible materials such as wall board, gypsum board, sheet rock, drywall, plywood,
etc. may be butted up next to the sides and top
of the rebox. Combustible materials should never overlap the rebox front facing.
WARNING: Do not allow any
combustible materials to overlap
the rebox front facing.
IMPORTANT: Noncombustible materials such
as brick, tile, etc. may overlap the front facing,
but should never cover any necessary open­ings like louvered slots or screen assembly.
WARNING: Do not allow noncombustible materials to cover any necessary openings like louvered slots.
WARNING: Use only noncom­bustible mortar or adhesives when overlapping the front facing with noncombustible facing material.
Figure 14 - Rough Opening for Installing
Nails or Wood
Screws
Figure 15 - Attaching Fireplace to Wall
in Corner
1
41
/2"
1
/4"
71
Nailing Flange
Studs
www.SuperiorFireplaces.US.com
*14 1/2"
Figure 16 - Minimum Mantel Clearances
for Built-In Installation
126868-01A12