Superior VRE4536WS, VRE4542WS, VRE4542WH, VRE4550WS, VRE4536WH Installation And Operation Instructions Manual

...
Installation and Operation Instructions
Universal Outdoor Vent-Free Firebox
P/N 127029-01 REV. D 01/2017
Ce manuel est disponible en francais, simplement en faire la demande. Numéro de la pièce 127029-02.
P127029-01
PFS
®
USC
Report No. F09-130
Models
VRE4536WS VRE4536WH
VRE4542WS VRE4542WH
VRE4550WS VRE4550WH
SAVE THIS BOOK
This book is valuable. In addition to instructing you on how to install and maintain your appliance, it also contains information that will enable you to obtain replacement parts or accessory items when needed. Keep it with your other important papers.
INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property dam­age. Refer to this manual for correct installation and operational procedures. For assistance or additional information consult a qualifi ed installer, service agency or the gas supplier.
This fi replace is approved for use on an outdoor application provided that a certifi ed gas log set approved under the
With Refractory Panels
ANSI Z21.97 standard with a maximum input rate of 40,000 BTU's is used.
a vent-free log heater (see Parts, Page 17).
An IHP hood must be installed when using
DO NOT INSTALL THE APPLIANCE IN THIS FIREBOX, UNLESS THIS FIREBOX MEETS THE MINIMUM DIMENSIONS REQUIRED FOR THE INSTALLATION.
WARNING: FOR USE ONLY WITH A LISTED, GAS-FIRED UNVENTED DECORATIVE ROOM HEATER NOT TO EXCEED
40,000 BTU/H.
DO NOT BUILD A WOOD FIRE.
WARNING:
FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury, death, or property damage.
AVERTISSEMENT:
RISQUED’INDENDIE OU D’EXPLOSION Le non-respect Des avertissements de sécurité pourrait d’entraîner des blessures graves, la mort ou des dom­mages matériels.
- Do not store or use gasoline or other fl ammable vapors and liquids in the vicinity of this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from a neigh­bor’s phone. Follow the gas supplier’s instruc­tions.
• If you cannot reach your gas supplier, call the fi re department.
- Installation and service must be performed by a qualifi ed installer, service agency or the gas supplier.
- Ne pas entreposer ni utilizer d’essence ni d’autres vapeurs ou liquides infl ammables dans le voisinage de cet appareil ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d’allumer d’appareil.
• Ne touchez à aucan interrupteur. Ne pas vous servir des téléphones se trouvant dans le bâtiment où vous trouvez.
• Sortez immédiatement de bâtiment.
• Appelez immédiatement votre fournisseur de gaz depuis un voisin. Suivez les instructions du fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz, appelez le service des incindies.
- L’installation et l’entretien doivent être assurés par un installateur ou un service d’entretien qualifi é ou par le fournisseur de gaz.
Thank you for your purchase. We appreciate your business!
Please carefully read and follow all instructions in this manual. Pay special attention to all warnings and safety information.
Following these safety, care, and operation instructions will help ensure many years of dependable and enjoyable service from your fi replace.
Please read and understand these instructions before installing or operating.
SAFETY
TABLE OF CONTENTS
Safety ............................................................................................. 2
Local Codes ................................................................................... 3
Product Features ............................................................................ 3
Requirements for the Commonwealth of Massachusetts............... 3
Locating Firebox ............................................................................ 3
Product Specifi cations ................................................................... 4
Air for Combustion and Ventilation ................................................ 7
Installation ..................................................................................... 9
Parts ............................................................................................ 14
Technical Service ......................................................................... 18
Replacement Parts ....................................................................... 18
Accessories .................................................................................. 18
Warranty ...................................................................................... 19
NOTICE: The fi rebox canopy must not be modifi ed or replaced with a canopy that may be provided with the unvented decorative room heater.
IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, operate or service this fi replace. Improper use of this fi replace can cause serious injury or death from burns, fi re, explosion, electrical shock and carbon monoxide poisoning.
DANGER: Carbon monoxide poisoning may lead
to death!
WARNING: Any change to this heater or its controls
can be dangerous.”
WARNING: Do not allow fans to blow directly into
the fi rebox. Avoid any drafts that alter burner fl ame patterns. Ceiling fans can create drafts that alter burner fl ame patterns. Altered burner patterns can cause sooting.
WARNING: Do not use a blower insert, heat
exchanger insert or other accessory not approved for use with this fi rebox.
Due to high temperatures, the appliance should be located out of traffi c and away from furniture and draperies.
Do not place clothing or other fl ammable material on or near the appliance. Never place any objects in the fi rebox or on logs.
Firebox front and screen becomes very hot when running fi rebox. Keep children and adults away from hot surfaces to avoid burns or clothing ignition. Firebox will remain hot for a time after shutdown. Allow surfaces to cool before touching.
Keep the fi replace area clear and free from combustible materials, gasoline, and other fl ammable vapors and liquids.
You must operate this fi replace with the provided fi replace screen and hood in place. Make sure these parts are in place and screens are closed before running installed gas log heater. Replace hood with IHP catalog no. (J4353) 50", (J4354) 42", or (J4355) 36" only. This hood has been designed to keep the operation of your fi replace safe and effi cient.
WARNING: If the information in this manual is not
followed exactly, a fi re or explosion may result caus­ing property damage, personal injury or loss of live
Children and adults should be alerted to the hazard of high surface temperature and should stay away to avoid burns or clothing ignition.
Young children should be carefully supervised when they are in the same room with the appliance.
SuperiorFireplaces.US.com 127029-01D2
SAFETY Continued
Installation and repair should be done by a qualifi ed service person. The appliance should be inspected before use and at least annually by a professional service person. More frequent cleaning may be re­quired due to excessive lint from carpeting, bedding material, etc. It is imperative that control compart­ments, burners and circulating air passageways of the appliance be kept clean.
1. Do not use this fi rebox as a wood burning fi replace. Use only decorative unvented room heaters (log sets).
2. Do not add extra logs or ornaments such as pine cones, vermiculite or rock wool. Using these added items can cause sooting.
3. Use only the provided hood. See Parts, Page 15.
4. Vent-free gas log heaters installed in these fi reboxes require fresh air ventilation to run properly. See Air for Combustion and Ventilation, Page 7.
5. Do not run vent-free heaters installed in these fi reboxes
• where fl ammable liquids or vapors are used or stored
• under dusty conditions
6. Do not use this fi rebox to cook food or burn paper or other objects.
7. Turn unit off and let cool before servicing. Only a qualifi ed service person should service and repair fi rebox.
8. Operating vent-free heaters installed in these fi reboxes above elevations of 4,500 feet could cause pilot outage.
9. Do not use the fi rebox if it has been under water.
10. Before using furniture polish, wax, carpet cleaner or similar products, turn heater off. If heated, the vapors from these products may create a white powder residue within burner box or on adjacent walls and furniture.
11. Provide adequate clearances around air openings.
LOCAL CODES
Install and use fi rebox with care. Follow all local codes. In the ab­sence of local codes, use the latest edition of The National Fuel Gas Code ANSI Z223.1/NFPA 54*; National Fuel Gas Code; Natural Gas and Propane Installation Code, CSA B149.1; or Propane Storage and Handling Code, CSA B149.2, as applicable. Firebox must be electri­cally grounded in accordance with the National Electrical Code, ANSI/ NFPA 70 (latest edition).
*Available from:
American National Standards Institute, Inc.
25 West 43rd Street, 4th fl oor
New York, NY 10036
National Fire Protection Association, Inc.
1 Batterymarch Park
Quincy, MA 02169-7471
PRODUCT FEATURES
OPERATION
This fi rebox is designed for use with approved ANSI Z21.11.2 deco­rative type unvented room heaters. (Physical size limitations apply. Refer to minimum fi rebox requirements supplied with log heater.) It requires no outside venting or chimney making installation easy and inexpensive.
COMMONWEALTH OF MASSACHUSETTS REQUIREMENTS
These appliances are approved for installation in the US state of Massachusetts if the following additional requirements are met:
Un-vented Room Heaters shall be installed in accordance with 527 CMR 30.
Installation and repair must be done by a plumber or gas fi tter licensed in the Commonwealth of Massachusetts.
The fl exible gas line connector used shall not exceed 36 inches (92 centimeters) in length.
The individual manual shut-off must be a T-handle type valve.
Unvented appliances may NOT be installed in bedrooms or bathrooms.
A working smoke detector must be installed in the area where vent-free appliances are installed.
Seller of unvented propane or natural gas-fi red supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon
sale of the unit.
LOCATING FIREBOX
PLANNING
Plan where you will install the fi rebox. This will save time and money later when you install the fi rebox. Before installation, consider the
following:
1. Where fi rebox will be located. Allow for wall and ceiling clearances
(see Installation Clearances, Page 9).
2. Everything needed to complete installation.
3. These models CANNOT be installed in a bedroom unless maximum
Btu rating of installed vent-free log set is less than 10,000 Btu/hr.
4. Proper air for combustion and ventilation (Page 7).
OUTDOOR ENCLOSURE REQUIREMENTS
Must conform to one of the following conditions:
With walls on all sides, but with no overhead cover;
Within a partial enclosure which includes an overhead cover and no more than two side walls. These side walls may be parallel, as in breezeway or at right angles to each side; or
Within a partial enclosure which includes an overhead cover and three sidewalls, as long as 30% or more of the horizontal periphery of the enclosure is permanently open.
SuperiorFireplaces.US.com127029-01D 3
36" MODELS
PRODUCT SPECIFICATIONS
54-
30-
1
/2"
1
11-
30"
/2"
3-
1
22-
29"
/2"
19"
20-1/4"
(Ref.)
7
4-
/8"
3
/4"
1
/8"
36" HEARTH
35-
1
/4"
1-
1
/4"
50"
3
36-
/8"
7-
7
7"
/8"
36"
1
/8"
45-
Figure 1 - 36" Models - VRE4536RS, VRE4536WS, VRE4536RH and VRE4536WH
SuperiorFireplaces.US.com 127029-01D4
9-
1
/2"
3
3-
/8"
3
/8"
7-
1
11-
/8"
42" MODELS
PRODUCT SPECIFICATIONS continued
54-
3
/8"
30-
3
/8"
32-
7
/8"
4-
3
3-
/4"
1
/8"
11-
1
/2"
3
/8"
26-
3
41-
/8"
42" HEARTH
21-
3
/4"
23"
(Ref.)
1
1-
/4"
50"
30"
36-
3
/8"
7-
1
/2"
7
7"
/8"
42"
1
51-
/8"
9-
3-
3
/8"
3
8-
/4"
13"
Figure 2 - 42" Models - VRE4542RS, VRE4542WS, VRE4542RH and VRE4542WH
SuperiorFireplaces.US.com127029-01D 5
50" MODELS
PRODUCT SPECIFICATIONS continued
54-
3
38-
/8"
3
34-
/8"
32-
3
/8"
21-3/4"
23"
(Ref.)
7
4-
3-
/8"
3
/4"
49-
3
/8"
50" HEARTH
1
/8"
11-
1
/2"
50"
30"
3
36-
/8"
7-
7
7"
/8"
50"
1
59-
/8"
9-
1
/2"
3
/8"
3-
3
8-
/4"
13"
Figure 3 - 50" Models - VRE4550RS, VRE4550WS, VRE4550RH and VRE4550WH
SuperiorFireplaces.US.com 127029-01D6
Loading...
+ 14 hidden pages