36" x 24", 36" x 28" & 42" x 28" Universal Vent-Free Fireboxes
P/N 700,032M REV. B 05/2006
MODELS
UVFRC-4228 Shown
INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE.
CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.
In the Commonwealth of Massachusetts:
• Installation must be performed by a licensed plumber or
gas fi tter;
• See Table of Contents for location of additional Commonwealth of Massachusetts requirements.
WARNING: DO NOT ATTEMPT TO BURN SOLID
WOOD FUELS, OTHER GAS LOG SETS OR ANY
OTHER COMBUSTIBLE MATERIALS IN THIS
VENT-FREE FIREBOX.
FOR YOUR SAFETY: Do not store or use gasoline
or other fl ammables or liquids in the vicinity of
this or any other appliance.
FOR YOUR SAFETY: What to do if you smell gas:
• DO NOT light any appliance.
• DO NOT touch any electrical switches.
• Do not use any phone in your building.
• Immediately call your gas supplier from a
neighbor’s phone. Follow your gas suppliers
instructions.
• If your gas supplier cannot be reached, call
the fi re department.
Installation and service must be performed by
a qualifi ed installer, service agency or the gas
supplier.
UVF-36
UVFRC-3628
UVFRC-4228
UVFRC-4228-H
UVFRC-3628-H
FOR USE ONLY WITH A LISTED GAS-FIRED UNVENTED DECORATIVE ROOM HEATER NOT TO EXCEED 40,000 BTU/H.
DO NOT BURN WOOD OR OTHER MATERIAL IN THESE
APPLIANCES.
WARNING: IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE INJURY OR
PROPERTY DAMAGE. REFER TO THIS MANUAL. FOR ASSISTANCE OR ADDITIONAL INFORMATION CONSULT A QUALIFIED
INSTALLER, SERVICE AGENCY OR THE GAS SUPPLIER.
CAREFULLY REVIEW THE INSTRUCTIONS SUPPLIED WITH
THE DECORATIVE TYPE VENT-FREE ROOM HEATER FOR THE
MINIMUM FIREPLACE SIZE REQUIREMENT.
DO NOT INSTALL AN APPLIANCE IN THIS FIREBOX, UNLESS
THIS FIREBOX MEETS THE MINIMUM DIMENSIONS REQUIRED
FOR THE INSTALLATIONS.
THIS IS A VENT-FREE GAS-FIRED HEATER ENCLOSURE. IT
USES AIR (OXYGEN) FROM THE ROOM IN WHICH IT IS INSTALLED. PROVISIONS FOR ADEQUATE COMBUSTION AND
VENTILATION AIR MUST BE PROVIDED. REFER TO COMBUSTION AND VENTILATION AIR SECTION, PAGES 3 & 4.
Due to high temperatures, the appliance should be located out
of traffi c and away from furniture or draperies.
Do not place clothing or other materials on or near this appliance.
OTL Report No.116-F-38-5
IMPORTANT: READ AND UNDERSTAND THESE INSTRUCTIONS
COMPLETELY BEFORE INSTALLING YOUR VENT-FREE ROOM
HEATERS.
IMPORTANT SAFETY
INFORMATION
INSTALLER: PLEASE LEAVE THESE INSTRUCTIONS WITH THE OWNER.
OWNER: PLEASE RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
WARNING
If the information in this
manual is not follwed
exactly, a fi re or explosion
may result causing property damage, personal
injury or loss of life.
IMPORTANT
The fi replace screens on the appliance must be closed prior to operating the fi replace.
WARNING
These built-in vent-free fi reboxes
have only been tested and approved
for use with ANSI Z21.11.2 Ventfree gas logs.
WARNING
Do not attempt to burn solid wood
fuels, other gas log sets or any
other combustible materials in
this vent-free fi rebox.
WARNING
Any change to this Vent-Free room
heater can be dangerous. Improper
installation or use of this heater can
cause serious injury or death from
fi re, burns, explosion or carbon
monoxide poisoning.
WARNING
Do not allow fans to blow directly
into the fi replace. Avoid any drafts
that alter burner fl ame patterns.
WARNING
Carbon Monoxide Poisoning: Early
signs of carbon monoxide poisoning
are similar to the fl u with headaches, dizziness and/or nausea. If
you have these signs, obtain fresh
air immediately. Have the Vent-Free
Gas Heater serviced as it may not
be operating correctly.
WARNINGS
• Due to high temperatures, the
fi rebox should be located out of
traffi c and away from furniture
and draperies.
• Do not place clothing or other
fl ammable material on or near
the heater.
• Any safety screen or guard removed for servicing the fi rebox
must be replaced and/or closed
prior to operating the heater.
• Installation and repair should
be done by a qualifi ed service
person. The heater should be
inspected before use and at
least annually by a professional
service person. More frequent
cleaning may be required due
to excessive lint from carpeting, bedding material, etc. It is
important that control compartments, burners and circulating
air passageways of the heater
be kept clean.
• Allow the heater to cool before
servicing. Always shut off any
electricity or gas to the heater
while performing service work.
• Do not install the fi rebox in a
sleeping room or bathroom.
• The appliance and its individual
shut-off valve must be disconnected from the gas supply piping
system while performing any
tests of the gas supply piping
system at test pressures equal
to or less than 1/2 psig.
WARNING
• The heater must be isolated from
the gas supply piping system by
closing its individual manual
shut-off valve during any pressure testing of the gas supply
piping system at test pressures
equal to or less than 1/2 psig.
• Keep heater area clear and free
from combustible materials,
gasoline and other fl ammable
vapors and liquids.
• Do not use this heater if any
part has been under water. Immediately call a qualifi ed service
technician to inspect the heater
and to replace any part of the control system and any gas control
which has been under water.
• Ensure that the heater is clean
when operating. Excessive dust
accumulation on the burner and
logs will increase the amount of
carbon monoxide formation and
could lead to carbon monoxide
poisoning and death.
IMPORTANT
Before starting your fi rebox installation, read these installation
instructions carefully to be sure you
understand them completely and
in entirety. Failure to follow these
instructions could cause a heater
malfunction resulting in serious
injury and/or property damage.
WARNING
Do not install in the vicinity where
gasoline or other fl ammable liquids
may be stored. The Vent-Free fi rebox must be kept clear and free from
these combustible materials.
WARNING
Maintain minimum clearances.
2
NOTE: DIAGRAMS & ILLUSTRATION ARE NOT TO SCALE.
CONGRATULATIONS!
Misc. Codes / Standards -
In selecting this SUPERIOR Vent-Free Gas Firebox you have chosen the fi nest and most
dependable fi replace to be found anywhere. A beautiful, prestigious, alternative to a
wood burning fi replace. Welcome to a family of tens of thousands of satisfi ed SUPERIOR
Fireplace Owners.
Please read and carefully follow all of the instructions found in this manual. Please pay
special attention to the safety instructions provided in this manual. The Homeowner's
Care and Operation Instructions included here will assure that you have many years of
dependable and enjoyable service from your SUPERIOR product.
TABLE OF CONTENTS
Important Safety Information ........... Page 2
Packaging List .................................. Page 3
General Information ......................... Page 3
Burn-in Period .................................. Page 3
Replacement Parts List .................... Page 17
This installation manual will help you obtain
a safe, effi cient, dependable installation for
your appliance and vent system.
PLEASE READ AND UNDERSTAND
THESE INSTRUCTIONS BEFORE BEGIN-
NING YOUR INSTALLATION.
Packaging List
Vent-Free Gas Firebox
(optional for models UVFRC-3628,
Canopy
UVFRC-3628-H, UVFRC-4228 & UVFRC-4228-H)
Installation and Operating Instructions
Warranty Certifi cate
GENERAL INFORMATION
These Vent-Free fi rebox enclosures are designed
to accept all ANSI Z21.11.2 approved Decorative Type Vent-Free Gas Log Room Heaters.
For the appropriate Vent-Free Gas Log Room
Heater model, refer to Page 16 (see
Gas Log Sets). Refer to the installation instruc-
tions provided with the log sets for detailed
instructions.
This installation manual will enable you to obtain
a safe, effi cient and dependable installation of
your room heater system.
Do not alter or modify the fi rebox or its
com ponents under any circumstances. Any
modifi cation or alteration of the fi rebox system,
including but not limited to the fi rebox and accessories, may void the warranty, listings and
approvals of this system and could result in an
unsafe and potentially dangerous installation.
These Built-In Vent-Free Fireboxes have been
tested and approved as Ventless Firebox Enclosures for Gas-Fired Unvented Decorative Room
Heaters to ANSI Z21.91.
Vent-Free
Burn-in Period
During the fi rst few times of operation of this
appliance there will be some odor due to the
curing of the paint and burning off of lubricants
used in the manufacturing process. We recommend that you open windows and ventilate the
house during the initial burns. The paint emits
non-toxic odors during this process.
Depending on your use, the burn-in period may
take a few hours or a few days.
KEEP YOUR HOUSE WELL VENTILATED
DURING THE BURN-IN PERIOD. THE ODOR
AND HAZE EMITTED DURING THE BURN-IN
PERIOD CAN BE QUITE NOTICEABLE AND MAY
SET OFF A SMOKE DETECTOR.
If an optional blower is installed, Do not turn it
on during the Burn-In period.
The Installation must conform to local codes
or, in the absence of local codes, with the
National Fuel Gas Code, ANSI Z223.1/NFPA 54
- latest edition.
The appliance, when installed, must be electrically grounded in accordance with local codes or,
in the absence of local codes, with the National
Electrical Code, ANSI/NFPA 70 - latest edition.
Check the packaging list to be sure that you have
all the necessary parts in usable condition. Also
check for concealed damage.
Tools and Building Supplies
Normally Required
Tools Should Include:
• Phillips screwdriver
• Hammer
• Saw and/or sabersaw
• Level
• Measuring tape
• Electric drill and bits
• Pliers
• Square
• Piping complying with local codes
• Pipe wrench
• Tee joint
• Pipe compound
Building Supplies Should Include:
• Framing materials
• Wall fi nishing materials
• Caulking materials
• Fireplace surround materials
(noncombustible)
• Insulation
(for packing around gas-line penetration holes)
(noncombustible)
CODES
Adhere to all local codes or in their absence
the latest edition of The National Fuel Gas Code
ANSI Z223.1 or NFPA 54 which can be obtained
from The American National Standards Institute,
Inc. (1430 Broadway, New York, NY, 10018) or
National Fire Protection Association, Inc. (Batterymarch Park, Quincy, MA, 02269).
COMBUSTION AND VENTILATION AIR
Heaters installed in these appliances shall
not be installed in a confi ned space. Heaters
installed in these appliances may be located
in unusually tight construction provided the
space is unconfi ned, or if confi ned, is provided
with two permanent openings communicating
directly with an additional room(s) of suffi cient volume so that the combined volume
of all connected spaces meets the criteria for
an unconfi ned space, (National Fuel Gas Code
ANSI Z223.1 1992, Section 5.3). Generally 50
3
ft
per 1,000 BTU input of all operating appli-
ances in the space.
NOTE: DIAGRAMS & ILLUSTRATION ARE NOT TO SCALE.
3
The National Fuel Gas Code defi nes a confi ned
space as a space whose volume is less than
3
50 ft
per 1,000 BTU/Hr (4.8 m3 per kw) of the
aggregate input rating of all appliances installed
in that space and an unconfi ned space as a space
whose volume is not less than 50 ft
3
per 1,000
BTU/Hr (4.8 m3 per kw) of the aggregate input
rating of all appliances installed in that space.
Rooms communicating directly with the space
in which the appliances are installed, through
openings not furnished with doors, are considered a part of the unconfi ned space.
Unusually tight construction is defi ned as
construction where:
a. Walls and ceilings exposed to the outside
atmosphere have a continuous water vapor
retarder with a rating of one perm or less with
openings gasketed or sealed, and
b. Weather stripping has been added on oper-
able windows and doors, and
c. Caulking or sealants are applied to areas such
as joints around window and door frames,
between sole plates and fl oors, between
wall-ceiling joints, between wall panels, at
penetrations for plumbing, electrical, and
gas lines, and at other openings.
Use the following equations to determine if you
have a confi ned or unconfi ned space.
1. Determine the volume of space — ft
Length x Width x Height = _____ ft
3
.
3
(Include adjoining rooms with doorless
passageways or ventilation grills between
rooms).
Example: 24' (L) x 16' (W) x 8' (H) = 3072
3
ft
2. Divide the volume of space by 50 ft 3 to
determine the maximum BTU/Hr the space
can support.
3
(volume of space – ft
)/ 50 ft 3 = (Maximum
BTU/Hr the space can support)
3
Example: 3072 ft
/ 50 ft 3 = 61.44
or 61,440 BTU/Hr the space can support.
3. Add the BTU/Hr of all the fuel burning appli-
ances in the space.
Vent-Free heater ________ BTU/Hr
Gas appliance #1* ________ BTU/Hr
Gas appliance #2 +________ BTU/Hr
Total =________ BTU/Hr
Example:
Vent-free heater 26,000 BTU/Hr
Gas appliance #1 40,000 BTU/Hr
(water heater)
Total = 66,000 BTU/Hr
* Do not include direct-vent gas appliances.
Direct-vent is sealed combustion and draws
combustion air from the outdoors.
4. Compare the maximum BTU/Hr the space can
support with the actual amount of BTU/Hr
used.
_________ BTU/Hr
(max. the space can support)
_________ BTU/Hr
(actual amount of BTU/Hr used)
Example:
61,440 BTU/Hr
(max. the space can support)
66,000 BTU/Hr
(actual amount of BTU/Hr used)
The space in the above example is a confi ned
space because the actual BTU/Hr used is more
than the maximum BTU/Hr the space can support. You must provide additional fresh air.
WARNING
If the area in which the heater may
be operated is smaller than that
defi ned as an unconfi ned space,
provide adequate combustion and
ventilation air by one of the methods
described in the National Fuel Gas
Code, ANSI Z223.1 1992, Section
5.3 or applicable local codes.
Your options are:
a. Rework equations adding the space of adjoin-
ing room(s). If the extra volume provides an
unconfi ned space, then remove door or add
ventilation grills between rooms. Refer to
National Fuel Gas Code, ANSI Z223.1 1992,
Section 5.3.
b. Vent room directly to the outdoors. Refer to
National Fuel Gas Code, ANSI Z223.1 1992,
Section 5.3.
c. Install a lower BTU/Hr heater, such as a 21,000
BTU/Hr, to make the area an unconfi ned
space.
If the actual BTU/Hr used is less than the
maximum BTU/Hr the space can support, then
the space is an unconfi ned space. You will
need no additional fresh air ventilation for an
unconfi ned space.
COLD CLIMATE INSULATION
For cold climate installations, seal all cracks
around the appliance with noncombustible
material and wherever cold air could enter
the room. It is especially important to insulate
outside cavities between studs and under fl oor
on which the appliance rests, if fl oor is above
ground level. Gas line holes and other openings
should be caulked with high temperature caulk
or stuffed with unfaced fi berglass insulation. If
the fi replace is being installed on a cement slab,
in cold climates, a sheet of plywood or other
raised platform can be placed underneath to
prevent conducting cold up into the room. It also
helps to
sheetrock inside surfaces and tape for
maximum air tightness and caulk fi restops.
NEW YORK CITY, NEW YORK (MEA)
Installation of these fi replaces are approved for
installation in New York City in the US state of
New York.
4
NOTE: DIAGRAMS & ILLUSTRATION ARE NOT TO SCALE.
Note: The following requirements reference various Massachusetts
and national codes not contained in this document.
(e)Unvented propane or natural gas-fi red space/room heaters shall
be prohibited in bedrooms and bathrooms.
Requirements for the Commonwealth of Massachusetts
Un-vented Room Heaters shall be installed in accordance with 527 CMR
30.00 and 248 CMR 3.00 through 7.00:
(a) Permits and Inspections: In addition to complying with 248 CMR
3.05 the following requirements must be satisfi ed:
1. A permit shall be obtained from the head of the fi re department and
the local or state gas inspector having jurisdiction for the installation
of all unvented propane or natural gas-fi red space/room heaters.
2. The permits shall be conditioned upon fi nal inspection and approval
of installation by the head of the fi re department and the local or state
gas inspector having jurisdiction.
3. A copy of the manufacturer’s installation/operating literature shall be
submitted with each permit application.
4. Before operation, the Head of the Fire Department and the local or
state gas inspector shall inspect the installation for compliance with
527 CMR (Board of Fire Prevention Regulations) and 248 CMR (Board
of State Examiners of Plumbers and Gas Fitters).
5. A fi nal inspection by the state or local gas inspector of the unvented
space/room heater shall not be performed until proof is provided
that the head of the fi re department having jurisdiction has granted
a permit.
(f)Space/room heaters shall be properly sized for the room or space
of installation, but shall not exceed a maximum of 40,000 BTU
input per room or space.
(g)In occupancies with an unvented propane or natural gas-fi red
space/room heater, no less than one listed carbon monoxide
detector that is installed in accordance with the manufacturers
instructions shall be installed and maintained near the space
where the heater is located.
1. Any building wherein the heater is to be installed shall,
as a precondition to such installation, have working smoke
detectors installed and maintained in accordance with the
requirements of 780 CMR (State Board of Building Regulations
and Standards) in effect at the time of construction or;
2. If no requirement was in effect at the time of construction the smoke detector shall be compliant and installed as
provided for in M.G.L. c. 148, § 26E.
(h)In rooms and buildings served by an unvented propane or
natural gas-fi red space/room heater, a primary source of heat,
which is operable, shall be permanently installed and maintained
in the building in accordance with 105 CMR (Department of
Public Health).
(i)Sellers of unvented propane or natural gas-fi red space/room
heaters shall provide to each purchaser a copy of 527 CMR
30.00 upon sale of the unit.
(b)Unvented propane or natural gas-fi red space/room heaters
shall conform to ANSI Z21.11.2, be equipped with an oxygen
depletion safety (ODS) shutoff system and be Product-approved
in accordance with 248 CMR.
(c)Unvented propane or natural gas-fi red space/room heaters
shall be installed in accordance with their listings and the
manufacturer’s instructions. Proper clearances to combustibles
shall be maintained. In no case shall the clearances be such as
to interfere with combustion air and accessibility.
(d)Installations shall be of a permanent type, with a permanently
piped fuel supply in accordance with 248 CMR. LPG appliances
shall be subject to the storage requirements in accordance with
527 CMR 6.00. Portable unvented propane or natural gas-fi red
space/room heaters shall be prohibited.
• Installation and repair must be done by a plumber or gas fi tter licensed
in the Commonwealth of Massachusetts.
• The fl exible gas line connector used shall not exceed 36 inches (92
centimeters) in length.
• The individual manual shut-off must be a T-handle type valve.
NOTE: DIAGRAMS & ILLUSTRATION ARE NOT TO SCALE.
5
LOCATION OF FIREBOX
Carefully select the best location for installation
of your built-in Vent-Free fi rebox. The following
factors should be taken into consideration:
• Clearance to side wall, ceiling, woodwork
and windows.
• Location must not be affected by drafts
caused by kitchen exhaust fans, return air
registers for forced air furnaces/air conditioners, windows or doors.
• Installation must provide adequate ventila-
tion and combustion air.
• Do not install this fi rebox in a sleeping room
or bathroom.
• Location should be out of high traffi c areas
and away from furniture and draperies due
to heat from fi rebox.
• Never obstruct the front opening of the
Vent-Free fi rebox or restrict the fl ow of
combustion and ventilation air.
• Minimize modifi cations to existing construction. See Figure 1 for location suggestions.
CAUTION
WARNING
Do not install these built-in VentFree fi reboxes in sleeping quarters,
or in recreational vehicles.
WARNINGS
Do not install these appliances:
• Where curtains, furniture, clothing or other fl ammable objects
are less than 42" from the front of
the Vent-Free room heater.
• In high traffi c areas.
• In windy or drafty areas.
40"
16"
Optional
Hearth
Extension
Figure 2
Ceiling clearance: The ceiling must be at
least 40" from the top of the fi rebox opening
(Figure 2 ).
Noncombustible material: Noncombustible
materials, such as slate and marble, must be
at least 1/2" thick and may be used without
restriction above the fi rebox opening, to the
sides or as a hearth extension, so long as
they do not obstruct vent openings for heat
circulating models.
RECOMMENDATION: Use high temperature
fi nish material for the mantels and/or use
the canopy (for UVFRC-3628, UVFRC-3628H, UVFRC-4228 & UVFRC-4228-H).
Do not install in the vicinity where
gasoline or other fl ammable liquids
may be stored. The Vent-Free fi rebox must be kept clear and free from
these combustible materials.
WARNING
Do not use a blower insert, heat
exchanger insert or other accessory not approved for use with this
fi replace.
Not to Scale
Figure 1
Clearances
Ensure the minimum clearances shown in
Figures 2 through 6 are maintained. Left and
right clearances are determined when facing
the front of the fi rebox.
Follow these instructions carefully to ensure safe
installation. Failure to follow these requirements
may create a fi re hazard.
Sidewall clearances: The sides of the fi rebox
opening must be at least 16" from any combustible wall (Figure 2 ).
Combustible Wall Clearance
Above Appliance (all models)
Finished Wall
Non-Combustible
Material
(shaded area)
Shown with Canopy
Installed (required on
UVF-36 only)
3" Min.
Figure 3
Header
Top Stand-
Off Spacer
(on appliance)
Top of Appliance
Fireplace
Opening
6
NOTE: DIAGRAMS & ILLUSTRATION ARE NOT TO SCALE.
Combustible Mantel and Trim Clearance
Combustible Mantel and Trim Clearance
Model UVF-36 WITH Canopy Installed
Canopy is required on all installations for this model only.
Safe Zone
Combustible Mantel
and Trim
18”
17”
16”
15”
14”
13”
12”
11”
10”
9”
Example
EXAMPLE: If you choose to install a mantel that projects 5", you will need to
install it so that the bottom of the mantel and trim is approximately 13" or more
above Firebox opening (see coordinate in shaded area above).
6”
8”
7“
Top of Firebox Opening
5”
Coordinate
in ()Example
3”
4”
Example
Canopy
Combustible
Material (wall)
Header
Top Spacer
on Appliance
Non-Combustible
Material 3” Min.
Top of Appliance
Screen
Figure 4
Models UVFRC-3628 and UVFRC-4228 WITHOUT Canopy Installed
Canopy is optional on these models
Safe Zone
Combustible Mantel
and Trim
24”
23”
22”
21”
7”
Coordinate
in ()Example
6”
Example
20”
19”
18”
17”
16”
8”
9”
10”
Example
Top of Firebox Opening
EXAMPLE: If you choose to install a mantel that projects 7", you will need to install it
so that the bottom of the mantel and trim is approximately 19" or more above Firebox
opening (see coordinate in shaded area above).
Combustible
Material (wall)
Header
Top Spacer
on Appliance
Non-Combustible
Material 3” Min.
Top of Appliance
Screen
Figure 6
Combustible Mantel and Trim Clearance
Models UVFRC-3628 and UVFRC-4228 WITH Canopy Installed
Canopy is optional on these models
Safe Zone
Combustible Mantel
and Trim
16”
15”
14”
13”
12”
11”
10”
9-1/2”
Example
Top of Firebox Opening
EXAMPLE: If you choose to install a mantel that projects 4", you will need to install it
so that the bottom of the mantel and trim is approximately 13" or more above Firebox
opening (see coordinate in shaded area above).
5”6”
Coordinate
in ()Example
3”
4”
Example
Canopy
2”
Combustible
Material (wall)
Header
Top Spacer
on Appliance
Non-Combustible
Material 3” Min.
Top of Appliance
Screen
Figure 5
Noncombustible material (minimum requirements) with wood mantel or
other combustible projections: To install the fi rebox with a wood mantel,
shelf or other combustible projection above fi rebox opening. Refer to
Figures 4, 5 & 6.
WARNING
The canopy must be in place to be in compliance with
the clearances specifi ed in Figures 4 & 5. Do not remove
or replace canopy, only use canopy supplied or offered
for these fi reboxes (see Pages 16 & 17). Do not use any
canopy which may be provided with the decorative type
Vent-Free room heater.
If your mantel profi le is unsafe, you may either:
• Raise the mantel to an acceptable
height, or
• Remove the mantel.
Floor clearance: These fi replaces may sit directly on a combustible surface.
The appliance should be mounted on a fully supported base extending the
full width and depth of the unit. The appliance may be located on or near
conventional construction materials. However,
if installed on combustible materials, such as carpeting, vinyl tile, etc., a metal
or wood barrier covering the entire bottom surface must be used.
NOTE: DIAGRAMS & ILLUSTRATION ARE NOT TO SCALE.
7
ASSEMBLY STEPS
Notes:
• Illustrations shown in this manual refl ect
“typical” installations with nominal dimensions and are for design and framing reference only. Actual installations may vary due
to individual design preferences. However,
always maintain minimum clearances to
combustible materials and do not violate any
specifi c installation requirements. Refer to
s
the Framing Specifi cations Figure
11.
• The following steps represent the normal
sequence of installation. Each installation
is unique, however, and might require a
different sequence.
Step 1. Position fi rebox prior to framing or
into prepared framing.
Step 2. Field wire the main power supply to
the appliance if a blower kit is to be installed
(at the time of installation or a later date).
An optional junction box kit and blower kit is required (see Page 15
Follow the installation and wiring instructions on
Pages 12 through 14). Electrical connections
should only be performed by an experienced,
licensed/certifi ed tradesman.
Step 3. Plumb gas line. (Gas connections
should only be performed by an experienced,
licensed/certifi ed tradesman).
Step 4. Install decorative type Vent-Free room
heater per the instructions provided with the
Vent-Free room heater.
Step 5. Complete fi nish wall material, surround and optional hearth extension to your
individual taste.
for ordering information).
on Page
Consult all local codes.
Properly size and route the gas supply line
from the supply regulator to the area where the
appliance is to be installed per requirements
outlined in the National Fuel Gas Code, NFPA
54 - latest edition (USA) or B149 - latest edition
(Canada). Never use galvanized or plastic pipe.
Gas lines must be routed, constructed and made
of materials that are in strict accordance with
local codes and regulations. We recommend
that a qualifi ed individual such as a plumber
or gas fi tter be hired to correctly size and route
the gas supply line to the appliance. Installing
a gas supply line from the fuel supply to the
appliance involves numerous considerations of
materials, protection, sizing, locations, controls,
pressure, sediment, and more. Certainly no one
unfamiliar and unqualifi ed should attempt sizing
or installing gas piping.
Remove the gas line access cover plate on either
the left or right side of the fi replace (see Figure 8 showing locations).
Install 1/2" min. to 1-1/2" max. inside diameter
approved gas line through the fi rebox wall for
connection to the Vent-Free room heater inside
the fi rebox. Connect the gas line before the
fi rebox is enclosed in the fi nished wall. Gas line
holes and other openings should be caulked with
high temperature caulk or stuffed with unfaced
fi berglass insulation.
Ensure that a sediment trap is installed in the
existing gas line, if not, install a sediment trap
upstream of the heater to prevent moisture
and contaminants from passing through trap
to the heater controls and burners. Failure to
do so could prevent the heater from operating
reliably.
An external regulator must be used on all propane (L.P.G). heaters, in addition to the regulator
fi tted to the heater, to reduce the supply tank
pressure to 13" W.C. (maximum). Any copper
tubing used to supply propane (L.P.G). from
the tank must be internally tinned.
IMPORTANT
Hold heater regulator with a wrench
to prevent movement when connecting to inlet piping.
WARNING
Connecting directly to an unregulated propane (L.P.G). tank can
cause an explosion.
IMPORTANT
Pack unfaced fi berglass insulation
material (not provided) around the
gas line access hole on appliance
and all exterior gas line penetration holes.
TEST ALL CONNECTIONS FOR GAS LEAKS
(FACTORY AND FIELD)
Test all gas joints from the gas meter to the
gas heater regulator for leaks using a gas leak
test solution (also referred to as bubble leak
solution).
Note: Using a soapy water solution as a leak
detection solution is not recommended because
the soap residue that is left on the pipes/fi ttings
can result in a false-positive leak detection reading
if a gas leak sniffer is used. Soap residue can also
result in corrosion over time.
DO NOT USE AN OPEN FLAME TO CHECK
FOR LEAKS.
Leak Test Procedure:
Turn on gas supply and test for gas leaks using
a gas leak test solution.
INSTALLATION
Gas Line Installation
CAUTION
Plumbing connections should
only be performed by a qualifi ed,
licensed plumber. Main gas supply
must be off when plumbing gas
line to fireplace or performing
service.
8
WARNING
Check Gas Type: The gas supply
must be the same as stated on the
heater’s rating plate. If the gas
supply is different, DO NOT INSTALL
the heater. Contact your dealer for
the correct model.
NOTE: DIAGRAMS & ILLUSTRATION ARE NOT TO SCALE.
A. Light the appliance (refer to the lighting
instructions label provided with gas logs).
B. Brush all joints and connections with the gas
leak detection solution. If bubbles are formed,
or gas odor is detected, turn the gas control
knob (off/pilot/on) to the “OFF” position. Either
tighten or refasten the leaking connection, then
retest as described above.
C. When the gas lines are tested and found to
be leak free, rinse off the leak testing solution
from gas line fi ttings.
Firebox Framing
Construct fi rebox framing following Figures
9 through 11 and Table 1 on Page 11 for
your specifi c installation requirements. Refer to
Figure 8 on Page 10 for fi rebox dimensions.
The fi rebox may be installed directly on a
combustible fl oor or raised on a platform of
an appropriate height. Do not place fi rebox on
carpeting, vinyl or other soft fl oor coverings. It
may, however, be placed on fl at wood, plywood,
particle board, metal or other hard surfaces
which extend the full width and depth of the
enclosure. Be sure fi rebox rests on a solid
continuous fl oor or platform with appropriate
framing for support and so that no cold air can
enter room from under the fi rebox.
CAUTION
Do not block the heat-circulating
air inlets and outlets on these
fi reboxes. Doing so may create a
potential fi re hazard.
3. Note the fl oor construction, i.e. 2" x 6", 2" x
8" or 2" x 10", single or double joists, type
and thickness of fl oor boards.
4. Use this information and consult your lo-
cal building code to determine if you need
additional support.
If you plan to raise the fi rebox, build the platform assembly then position fi rebox on top.
Secure the platform to the fl oor to prevent
possible shifting.
Firebox Installation
Step 1. Frame these appliances as illustrated in
Figures 9 through 11. All framing details must
allow for a minimum clearance to combustible
framing members as shown in Figures 2 through 6. Also refer to appliance specifi cations
on Page 10 . Headers may be in direct contact
with the appliance top spacers but must not
be supported by them or notched to fi t around
them. All construction above the appliance must
be self supporting, DO NOTUSE THE APPLI-
ANCE FOR STRUCTURAL SUPPORT.
Note: The nailing fl ange and the area directly
behind the nailing fl ange is exempt from the
clearances described on the fi rebox clearance
label.
Step 4. To safely operate the heater with consideration of the mantel clearances the canopy
must be installed (Model UVF-36 Only).
IMPORTANT
Under no circumstances shall the
fi rebox top spacers be removed
or modifi ed (see Figure 8). The
header may be in direct contact
with the top spacers but must not
be supported by them or notched to
fi t around them.
Top Spacer
The fi rebox may be positioned and then the
framing built around it, or the framing may
be constructed and the fi rebox positioned into
the opening.
Usually, no special fl oor support is needed for
the fi rebox, however, to be certain:
1. Estimate the total weight of the fi rebox
system and surround materials such as
marble, brick, stone, etc., to be installed
(see Product Referance Table on Page 10
for appliance weight).
2. Measure the square footage of the fl oor
space to be occupied by the system and
surrounds.
Note: The framed depth from a framed wall,
must always be measured from a fi nished
surface. If a wall covering such as drywall is
to be attached to the rear wall, then the depth
must be measured from the drywall surface. It
is important that this dimension be exact.
Step 2. Level the fi rebox by checking the top
edge of the fi rebox. Shim if necessary.
Step 3. Fireplace should be secured to side
framing members using the full length nailing
tabs at the top and bottom of the fi replace front
face. Use 8d nails (see Figure 7).
8d Nail
Figure 7
NOTE: DIAGRAMS & ILLUSTRATION ARE NOT TO SCALE.
9
SPECIFICATIONS
Dimensions - Inches (millimeters)
Model No.ABCDEFGHJKLMNP*Q
UVF-36
36
(914)24(610)
UVFRC-3628 &
UVFRC-3628-H36(914)28(711)
UVFRC-4228 &
UVFRC-4228-H42(1067)28(711)
Product Reference Information
Cat. No.ModelShip. Weight (lbs)Shipping Volume
H1957UVF-36150 lbs
H1953UVFRC-3628200 lbs
H1954UVFRC-3628-H200 lbs
H1955UVFRC-4228230 lbs
H1956UVFRC-4228-H230 lbs
41-3/4
(1061)
41-3/4
(1061)
47-3/4
(1213)
37-1/4
(946)
41-1/4
(1048)
41-1/4
(1048)
23-1/2
(597)20(508)3(76)
23-1/2
(597)20(508)3(76)
29-1/2
(749)20(508)3(76)
20 Cu. Ft.
22 Cu. Ft.
22 Cu. Ft.
26 Cu. Ft.
26 Cu. Ft.
7-3/8
(187)
8-3/8
(213)
8-3/8
(213)
15-7/8
15-7/8
15-7/8
(403)
(403)
(403)
7-1/2
(190)
7-1/2
(190)
7-1/2
(190)
11-15/16
(303)
11-15/16
(303)
11-15/16
(303)
1-5/16
(33)
1-5/16
(33)
1-5/16
(33)
5-1/2
(140)
5-1/2
(140)
5-1/2
(140)
30-5/16
(770)
34-5/16
(872)
34-5/16
(872)
* A canopy comes standard and is required for model UVF-36. The fac-
tory-supplied canopy must be installed on the fi rebox for safe operation
for model UVF-36 in all installations. This part is optional for models
UVFRC-3628, UVFRC-3628-H, UVFRC-4228 & UVFRC-4228-H.
29-5/8
(753)
33-5/8
(854)
33-5/8
(854)
1 (25)
7-1/16
(179)
Top of Bottom
Refractory
6-3/16
(157)
E
F
Top View
Junction Box
N
M
Top Stand-Off
Spacers (4
places)
Top of Firebox
Opening
* Canopy
B
Bottom of
Firebox
Opening
D
*Q
P
3-9/16
(90)
Gas Line
Access Both Sides
J
5-3/4
(146)
A
H
K
L
G
Access Opening for Junction
Box - Right Side Only
(remove the knock-out
before installing J-Box).
J-Box / Electrical Kit is not
provided with appliance.
C
Front View
Right Side View
10
Figure 8
NOTE: DIAGRAMS & ILLUSTRATION ARE NOT TO SCALE.
FRAMING SPECIFICATIONS
Framing Dimensions
OpeningUVF-36
UVFRC-3628 &
UVFRC-3628-H
A42-1/4" (1073)42-1/4" (1073)48-1/4" (1226)
B40-1/4" (1022)44-1/4" (1124)44-1/4" (1124)
C23-9/16" (599)23-9/16" (599)29-9/16" (751)
D11-1/4" (286)11-1/4" (286)14-1/4" (362)
E63-1/2" (1613)63-1/2" (1613)69-1/2" (1765)
F31-3/4" (807)31-3/4" (807)34-3/4" (883)
G20-1/2"( 521)20-1/2"( 521)20-1/2"( 521)
H44-3/16" (1122)44-3/16" (1122)49-1/8" (1248)
Table 1 -
This Table corresponds to Figures 9, 10 & 11
UVFRC-4228 &
UVFRC-4228-H
Header
This Figure corresponds to Table 1
H
Figure 10
Rough Framing Face
(Unfi nished Shown)
Corner Installation
Back Wall Of Chase/Enclosure
Including Finishing Materials
If Any
D
F
G
C
A
E
Rough Framing Face
(Unfi nished Shown)
Parallel Installation
Back Wall Of Chase/Enclosure
Including Finishing Materials If Any
C
This Figure corresponds to Table 1
Figure 9
B
A
Canopy Kit Installation (see ordering information on Page 16)
NOTE: A canopy comes standard and is required for model UVF-36.
The factory-supplied canopy must be installed on the fi rebox for safe
operation for model UVF-36 in all installations (this part is optional
for other models). See
These canopy kits are design to be fi tted to the face of the appliance
directly above the fi rebox opening. In addition to providing an aesthetically pleasing appearance to your appliance, the canopy reduces heat
effects to decorative mantels and fi nish materials located directly above
the fi replace and reduces the Mantel / Trim clearances (see Figures 4, 5 & 6 on Page 7).
Please read this entire manual and understood thoroughly before proceeding
with the installation of these kits.
Step 1. Using a 5/16" nut driver or socket, remove the screen and rod
assemblies as shown in Figure 12.
Step 2. Align the canopy with the holes in the side frames as shown in
Figure 13. Install three screws as shown in Figure 13. Make
sure canopy is level and secure.
Step 3. Reinstall screen and rod assemblies (see Figure 12).
Figure 13.
Figure 11
Removing Screens & Rods:
Remove screws (see dotted
lines). Pull out rods from
locating holes on side of fi rebox
opening.
Reinstalling Screens & Rods:
Insert rods into corresponding
locating holes on sides of fi rebox
opening, then reinstall screws
as shown.
Figure 12
G
A
This Figure corresponds to Table 1
NOTE: DIAGRAMS & ILLUSTRATION ARE NOT TO SCALE.
11
Canopy
IMPORTANT
The Ground Lead must be connected
to the green screw (located on the
junction box). Failure to do this
could result in an electrical short or
shock injury.
Top View
* Electrical Outlet
Blower
Bend blower mounting
tabs up to secure
blower in place
* Junction Box
Tie a loose knot in power
cord to take up slack
Side View
Figure 13
OPTIONAL EQUIPMENT
Blower Kits
The FBK-100 Blower Kits are used when
a wall-mounted ON/OFF blower switch is
desired, and the FBK-200 Blower Kits are
used when a wall-mounted variable speed
blower control (rheostat) is desired. A Junction Box / Electrical Kit is also required to install these
kits (purchased separately - see Page 15).
The blower is installed beneath the fi rebox.
Room air is drawn in through the side slots
of the fi replace, heated as it passes across the
fi rebox, and discharged through the upper area
of the fi rebox opening.
The installation instructions for installing these
blower kits are on Pages 12 through 14. Also see
the installation instructions provided with the
blower kits (Form #750,028M). For electrical
requirements, refer to Figures 14, 15 & 16.
If the blower kit is to be installed at the time of
installation or at a later date, the main power
supply must be installed at the time of installation. This will require that the electrical
connections must be made BEFORE the fi rebox
is framed and enclosed in the fi nished walls.
Route a 3-wire, 120 VAC, 60 Hz, 1 ph power
supply and connect to electrical receptacle wires
and wall switch or rheostat.
The appliance must be electrically
grounded in accordance with local
codes or, in the absence of local
codes, the national electrical code,
ANSI/NFPA 70-(latest edition). (In
Canada, the current CSA C22-1
Canadian Electrical Code).
CAUTION
Electrical connections should
only be performed by a qualifi ed,
licensed electrician. Main power
must be off when connecting to
main electrical power supply or
performing service.
Blower Motor
Grounded
to Appliance
Motor Plug
Receptacle
120V
Appliance Junction Box
Note: If any of the original wire as supplied must be
replaced, it must be replaced with type AWM 105
degree C - 14 gage wire.
Figure 14
* The Junction Box / Electrical Kit is not included.
See Page 15 for ordering information.
Figure 15
120V, 60HZ,
1PH BLOWER
CONTROL CIRCUIT
Tab
Intact
Ground
120 VAC Black
WIRING
* Wall-mounted ON/
OFF Blower Switch
or Variable Speed
Control Switch.
NEUTRAL
SIDE OF
RECEPTACLE
Green
Ground
Screw
Field Wired
Factory Wired
Ground - Green
Neutral - White
HOT SIDE OF
RECEPTACLE
Black
Junction
Box
Plug blower
into this
receptacle
Blower
*An ON/OFF Wall Switch is used with the FBK-100 kit
(fi eld provided or sold separately - order P/N 85L87); A
Variable Speed Control (provided) is used with the FBK200 kit. The installation of these kits also require a
Junction Box / Electrical Kit, not included. See Page
15 for ordering information.
Note: If any of the original wire as supplied must be
replaced, it must be replaced with type AWM 105
degree C - 14 gage wire.
12
Figure 16
NOTE: DIAGRAMS & ILLUSTRATION ARE NOT TO SCALE.
Installation Instructions -
FBK-100 or FBK 200 Blower Kits and JBK Junction Box Kit
IMPORTANT
Cover Plate
J-Box &
Receptacle
All electrical wiring must be performed by licensed Electricians. Electrical wiring must comply with the National
Electrical Code ANSI/ NFPA 70 - latest edition
Step 1. Follow the instructions below for the model you are installing:
Model UVF-36:
Using a screwdriver remove the screw from the blower access panel
as shown in Figure 18. Slide the panel to the right until the fl ange
clears the opening. Remove the panel and set aside.
Lift out the bottom refractory panel (see Figure 17).
Step 2. Remove the rectangular knock-out (for J-Box) on the right side
of unit (see Figure 8 for location). Install the Junction Box & Electrical
outlet below the fi rebox fl oor into the rectangular opening on the right
side cabinet panel where you removed the knock-out (see Figures 20 &
21). The Junction Box / Electrical Kit is sold separately (see Page 15 for
ordering information).
Note: Pass the wires through the hole, then squeeze the J-Box
fl anges together to fi t into opening.
Step 3. Loosely tie a knot in the power cord to take up slack (see Figure
22).
Step 4. Locate the tabs shown in Figure 23. Position the blower assembly
so that the tabs (located on the cabinet base) are seated in the notches of
the blower bracket. Bend the tabs over to secure the blower assembly (see
Figure 24).
Step 5. Plug power cord into the electrical outlet as illustrated in Figure 15.
Remove knock-out
(strain relief bushing
presses into this hole
around romex wires
Step 8. Ensure that power supply wires are NOT "live" before making
these connections). Install J-Box Cover Plate as follows:
Feed the * Romex wires (or other equivalent plastic insulated wire
- Refer ANSI/NFPA 70 - National Electrical Code - Latest Edition)
through the J-Box Cover retangular opening, then connect to the
J-box wires. The strain relief bushing should be pressed into the
knock-out on J-box cover around the Romex (this will provide
protection to the wires and prevents strain against connections
from J-box). See Wiring Diagram - Figure 16. Install the cover
plate over J-Box opening on appliance as shown in Figure 25.
Note: Wire connections should be positioned inside of the appliance.
* Romex is a plastic insulated wire from power supply - sometimes called
non-metallic sheath.
Model UVFRC-4228
Cabinet Base
Locating Tabs
Figure 23 -
UVFRC-4228 Shown
Bend Locating Tabs Over
(into notches)
Figure 24 - UVFRC-4228 Shown
Step 6. Route a 3-wire, 120 VAC, 60 Hz, 1 ph power supply to the right
side of appliance.
Step 7. Locate the J-Box cover (provided in J-Box Kit). Remove the round
knock-out (see Figure 19).
Right Side Panel of Firebox
J-Box opening
on appliance
Use screw provided and
secure in place as shown
Screw
Cover Plate
The notched side of
cover plates goes inside
fi rebox panel
Figure 25 - Installing J-box Cover Plate - All Models
Step 9. Follow the instructions below for the kit you are installing:
Reinstall the bottom refractory panel that was removed on Step 1
(see Figure 17).
14
NOTE: DIAGRAMS & ILLUSTRATION ARE NOT TO SCALE.
FIREBOX FINISHES
There are a wide variety of “fi nished looks” for your built-in Vent-Free fi rebox from formal wall
decor with elaborate mantels to rustic wood paneling or warm brick facings.
Only noncombustible materials like marble, stone, tile, brick, etc. may overlap the black front
facing. Seal all joints between the black facing and wall surrounds to prevent air intrusion. Use
noncombustible caulking material only to seal the black metal facing to the surround material on
the fi nished wall. See Figures 3 & 26.
Raised Hearth Extension
A hearth extension may be used but is not required for these appliances. A raised hearth extension
may be used as shown in Figure 26.
Combustible Wall
Non-Combustible Wall
(see Figure 4)
APPROVED ACCESSORIES AND
COMPONENTS
Decorative Arch Screen Panel Kit
This attractive screen door is easy to install and
enhances the appearance of the appliance.
Decorative Screen Door Panel Kit
Cat. No.ModelWhere Used
H1959ASD3624-TI UVF-36
H1960ASD3628-TI UVFRC-3628 & UVFRC-3628-H
H1961ASD4228-TI UVFRC-4228 & UVFRC-4228-H
(ref. Form # 750,209M)
Raised Hearth Extension
(combustibles allowed.
No carpet or vinyl)
5-3/4" Max.*
* From Base to
Bottom of Firebox
Opening (fl oor)
Combustible Platform
Figure 26 - Raised Hearth Extension
Fireplace Opening
Firebox Floor
Base
SIDE VIEW
NOTE: DIAGRAMS & ILLUSTRATION ARE NOT TO SCALE.
Decorative Volcanic Stone
Cat. No.Model No.Description
80L42FDVSBag of Volcanic Stone
(ref. Form #750,010M)
Decorative Volcanic Stone
The decorative volcanic stone, Model FDVS,
can be used to enhance the look of your appliance. Order model FDVS for replacement
of stone when needed. Spread the decorative
volcanic stone evenly around the bottom of
the fi rebox.
Junction Box / Receptical Kit
Cat. No.Model No.Description
H1958JBK
(ref. Form #750,203M)
Junction Box / Electrical Kit
15
APPROVED ACCESSORIES AND
COMPONENTS
Charcoal Canopy
Cat. #ModelModels Where Used
H1989FC36
H1990FC42
(ref. Form #750,195M)
UVFRC-3628, UVFRC-3628-H
(UVF-36 standard part)
UVFRC-4228 & UVFRC-4228-H
The variable speed control
rheostat is included with
FBK-200 models only
An ON/OFF wall switch can be used
with the FBK-100 models (fi eld
supplied or order P/N 85L87 Wall
Switch Kit, shown below)
Cat.
No.
80L84FBK-100Blower, Standard
80L85FBK-200Blower, Variable Speed
94L89FBK-100-36Blower, Standard, 36 Pack
94L90FBK-200-36Blower Kit - Variable Speed
(ref. Form # 750,028M)
* The installation of these kits also require a Junction Box / Electrical
Kit, not included. See ordering information below
* Forced Air Blower Kits
Model No.Description
(single speed)
(w/wall-mounted switch)
with Wall Switch 36 Pack
Blower Kit
The FBK-100 blower provides for a constant velocity forced air circulation feature for your appliance. The FBK-200 assembly with variable speed wall switch provides a forced air circulation
feature for your appliance.
Outside Air Gate & Duct Kit
Cat. No.Model No.Description
H3991OAK-UVFRCOutside Air Gate & Duct Kit
(ref. Form #750,206M)
Touch-Up Paint Kit
Repair of minor scratches and
discoloration of the appliance
charcoal painted surfaces may be
accomplished with the touch-up
P
A
paint kit.
T
N
I
ON/OFF Wall Switch Kit
The ON/OFF wall switch kit
may be used to control the
blower operation, if FBK100 blower kit is installed.
Install the ON/OFF wall
switch in a convenient
location near the fi replace.
Outside Air Gate & Duct Kit
These kits have an air gate assembly, 4" diameter duct and a termination hood. The air gate
allows adjustment of the amount of outside air
delivered to the fi re for combustion. Only one
kit, located on the right side of the fi replace,
Cat. No.Model No.Description
90L74TPK-CTouch-Up Paint (Charcoal)
(ref. Form # 504,216M)
Touch-Up Paint Kits
Cat. No.Model No.Description
85L87FWSKON/OFF Wall Switch Kit
is required.
SERENE HEAT ® VENT-FREE GAS LOG SETS - MANUAL / PIEZO IGNITION, STANDING PILOT
Cat. #ModelDescriptionBTU/hr InputModels Where Used
H2130VFGL28-MSN-428” Vent-Free Gas Log Set, Natural17,000 - 32,000UVFRC-4228 & UVFRC-4228-H
H2131VFGL28-MSP-428” Vent-Free Gas Log Set, Propane17,000 - 32,000UVFRC-4228 & UVFRC-4228-H
NOTE: DIAGRAMS & ILLUSTRATION ARE NOT TO SCALE.
REPLACEMENT PARTS
An exploded view of the fi rebox with numbered parts and a replacement parts list can be found on the Page. Normally, all parts should be ordered
through your distributor or dealer. Parts will be shipped at prevailing prices at time of order.
When ordering repair parts, always give the following information:
1. The *model number of the fi rebox.
2. The *serial number of the fi rebox.
3. The part number.
4. The description of the part.
5. The quantity required.
6. The installation date of the fi rebox.
* Note: The model and serial number can be found on the rating label located on the bottom left front corner of the appliance.
If you encounter any problems or have any questions concerning the installation of a Vent-Free heater in this system, please contact your distributor
or dealer or visit our website at www.lennox.com..
Part No.Qty.Part No.Qty.Part No.Qty.Part No.Qty.Part No.Qty.
H3814
H3815
H3809
H3810
H3811
H1989
2
2
1
1
1
1
H3820
H3815
H3817
H3816
H3819
H3818
H1989
2
2
1
1
1
1
1
H3820
H3815
H3822
H3821
H3823
H3818
H1989
2
2
1
1
1
1
1
H3827
H3828
H3817
H3816
H3824
H3825
H1990
2
2
1
1
1
1
1
H3827
H3828
H3830
H3829
H3831
H3825
H1990
2
2
1
1
1
1
1
NOTE: DIAGRAMS & ILLUSTRATION ARE NOT TO SCALE.
17
NOTES
18
NOTE: DIAGRAMS & ILLUSTRATION ARE NOT TO SCALE.
NOTES
NOTE: DIAGRAMS & ILLUSTRATION ARE NOT TO SCALE.
19
The manufacturer reserves the right to make changes at any time, without notice, in design, materials, specifi cations, prices and also to discontinue colors, styles and products.
Consult your local distributor for fi replace code information.