Superior NMC004-TD, NEC004-TD User Manual

HOMEOWNER'S CARE AND OPERATION INSTRUCTIONS
DIRECT VENT
DT-400 AND DR-400
33" DIRECT-VENT GAS FIREPLACE HEATERS P/N 725,023M REV. J 11/2004
MODELS
RETAIN THESE INSTRUCTIONS
OTL Report No. 116-F-17-4
WARNING: IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLO­SION MAY RESULT CAUSING PROPERTY DAM­AGE, PERSONAL INJURY OR LOSS OF LIFE.
FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors or liquids in the vicin­ity of this or any other appliance.
tlovilliM
sledoM
cinortcelE
sledoM
NMC004-TDNEC004-TD PMC004-TDPEC004-TD
NMC004-RDNEC004-RD PMC004-RDPEC004-RD
AVERTISSEMENT: ASSUREZ-VOUS DE BIEN SUIVRE LES INSTRUCTIONS DONNÉ DANS CETTE NOTICE POUR RÉDUIRE AU MINIMUM LE RISQUE D'INCENDIE OU POUR ÉVITER TOUT DOMMAGE MATÉRIEL, TOUTE BLESSURE OU LA MORT.
POUR VOTRE SÉCURITÉ: Ne pas entreposer ni utiliser d'essence ni d'autre vapeurs ou liquides inflammables dans le voisinage de cet appareil ou de tout autre appareil.
POUR VOTRE SÉCURITÉ: Que faire si vous sentez une odeur de gaz:
FOR YOUR SAFETY: What to do if you smell gas:
• DO NOT light any appliance.
• DO NOT touch any electrical switches.
• DO NOT use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone.
Follow your gas suppliers instructions.
• If your gas supplier cannot be reached, call the fire department.
Installation and service must be performed by a qualified installer, service agency or the gas supplier.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucun interrupteur. Ne pas vous servir des téléphones se trouvant dans le batiment où vous vous trouvez.
• Evacuez la piéce, le bâtiment ou la zone.
• Appelez immédiatement votre fournisseur de gaz depuis un voisin. Suivez les instructions du fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz, appelez le service dos incendies.
L'installation et service doit être exécuté par un qualifié installeur, agence de service ou le fournisseur de gaz.
1
CONGRATULATIONS!
.oNledoM
ezisecifirO
larutaNenaporP
004-TD
54#
840.0
hcni
004-RD
GENERAL INFORMATION
In selecting this SUPERIOR Direct-Vent Gas Appliance you have chosen the finest and most dependable fireplace to be found anywhere. A beautiful, prestigious, alternative to a wood burning fireplace. Welcome to a Family of tens of thousands of satisfied SUPERIOR Fireplace Owners.
Please read and carefully follow all of the instructions found in this manual. Please pay special attention to the safety instructions provided in this manual. The Homeowner's Care and Operation Instructions included here will assure that you have many years of dependable and enjoyable service from your SUPERIOR product.
TABLE OF CONTENTS
General Information......................... page 2
Operation/Care of Your Appliance.... page 3
Gas Control/Compartment Access... page 3 Variable Flame Adjustment
(Millivolt) ....................................... page 4
Glass Cleaning ................................. page 4
Maintenance .................................... page 4
Maintenance Schedule..................... page 5
Front Glass Enclosure Panel,
Removal and Installation ............... page 6
Burner Adjustments......................... page 6
Flame Appearance and Sooting ....... page 6
Adjustment ...................................... page 6
Log Placement................................. page 7
Glowing Embers Placement ............. page 7
Millivolt Appliance Checkout........... page 8
Electronic Appliance Checkout......... page 8
Wiring Diagrams.............................. page 8
Warranty.......................................... page 9
Replacement Parts .......................... page 9
Product Reference Information ....... page 9
Accessory Components ................... page 9
Millivolt Lighting Instructions .......... page 12
Electronic Lighting Instructions ....... page 14
Millivolt Troubleshooting Guide ........ page 16
Electronic Troubleshooting Guide ..... page 17
Replacement Parts List ..................... page 18
INTRODUCTION
The Fireplace models covered in this manual are Direct-Vent sealed combustion gas fire­place heaters designed for residential applica­tion. Direct-Vent appliances operate with the combustion chamber completely isolated from the inside atmosphere. All air for combustion is brought in from the outside and exhaust gases are vented through the same Direct Vent, vent system.
2
The millivolt appliances are designed to oper­ate on either natural or propane gas. A millivolt gas control valve with piezo ignition system provides safe, efficient operation.
External electrical power is required to operate the optional electrically powered components if installed. Electrical power must be wired during appliance installation.
The electronic appliances are designed to op­erate on either natural or propane gas. An electronic intermittent pilot system provides safe, efficient operation. External electrical power is required to operate these units.
These appliances comply with National Safety Standards and are tested and listed by Omni Test Laboratories (Report No. 116-F-17-4) to ANSI Z21.88-2002 (in Canada, CSA-2.33-
2002), and CAN/CGA-2.17-M91 in both USA and Canada, as vented gas fireplace heaters.
Installation must conform to local codes. In the absence of local codes, installation must comply with the current National Fuel Gas Code, ANSI Z223.1 (NFPA 54). (In Canada, the current CAN/CGA B149 installation code.) Elec­trical wiring must comply with local codes. In the absence of local codes, installation must be in accordance with the National Electrical Code, NFPA 70 - (latest edition). (In Canada, the current CSA C22.1 Canadian Electric Code.)
DO NOT ATTEMPT TO ALTER OR MODIFY THE CONSTRUCTION OF THE APPLIANCE OR ITS COMPONENTS. ANY MODIFICATION OR ALTERATION MAY VOID THE WARRANTY, CERTIFICATION AND LISTINGS OF THIS UNIT.
WARNING: IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE INJURY OR PROPERTY DAMAGE. REFER TO THIS MANUAL. FOR ASSISTANCE OR ADDI­TIONAL INFORMATION CONSULT A QUALIFIED INSTALLER, SERVICE AGENCY OR THE GAS SUPPLIER.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
Note: Installation and repair should be per­formed by a qualified service person. The appliance should be inspected annually by a qualified professional service technician. More frequent inspections and cleanings may be required due to excessive lint from carpeting, bedding material, etc.
It is imperative that the control compartment, burners and circulating air passage ways of the appliance be kept clean.
S'assurer que le brùleur et le compartiment des commandes sont propres. Voir les in­structions d'installation et d'utilisation qui accompagnent l'appareil.
Provide adequate clearances around air open­ings and adequate accessibility clearance for service and proper operation. Never obstruct the front openings of the appliance.
Due to high temperatures the appliance should be located out of traffic and away from furni­ture and draperies. Locate furniture and win­dow coverings accordingly.
WARNING: THESE FIREPLACES ARE VENTED HEATERS. DO NOT BURN WOOD OR OTHER MATERIAL IN THESE APPLIANCES.
These appliances are designed to operate on natural or propane gas only.
On Millivolt models the Input of the appliance can be varied from 13,500 to 17,500 BTU/HR. On Electronic models the input is fixed at 17,500 BTU/HR.
Maximum manifold pressure is 3.5 in. w.c. (0.87 kPa) for natural gas and 10 in. w.c. (2.49 kPa) for LP/Propane gas.
Do not use these appliances if any part has been under water. Immediately call a qualified, professional service technician to inspect the appliance and to replace any parts of the control system and any gas control which have been under water.
Ne pas se servir de cet appareil s'il a été plongé dans l'eau, complètement ou en partie. Appeler un technicien qualifié pour inspecter l'appareil et remplacer toute partie du système de contrôle et toute commande qui ont été plongés dans l'leau.
Test gage connections are provided on the front of the millivolt gas control valve (identi­fied OUT for the manifold side and IN for inlet pressure. A ¹⁄₈" NPT test gage connection is provided on the electronic gas control valve adjacent to the outlet to the main burner.
Minimum inlet gas pressure to these appliances is 5.0 inches water column (1.24 kPa) for natural gas and 11 inches water column (2.74 kPa) for propane for the purpose of input adjustment.
Maximum inlet gas supply pressure to these appliances is 10.5 inches water column (2.61 kPa) for natural gas and 13.0 inches water column (3.23 kPa) for propane.
The appliance must be isolated from the gas supply piping system (by closing its individual manual shut-off valve) during any pressure test­ing of the gas supply piping system at test pressures equal to or less than ¹⁄₂ psig (3.5 kPa).
The appliance and its individual shut-off valve must be disconnected from the gas supply piping system during any pressure testing of that system at pressures in excess of ¹⁄₂ psig (3.5 kPa).
These appliances must not be connected to a chimney or flue serving a separate solid fuel burning appliance.
Any safety guard or screen removed for servic­ing the appliance must be replaced prior to operating the appliance.
WARNING: FAILURE TO COMPLY WITH THE INSTALLATION AND OPERATING IN­STRUCTIONS PROVIDED IN THIS DOCU­MENT WILL RESULT IN AN IMPROP­ERLY INSTALLED AND OPERATING AP­PLIANCE, VOIDING ITS WARRANTY. ANY CHANGE TO THIS APPLIANCE AND/OR ITS OPERATING CONTROLS IS DANGER­OUS. IMPROPER INSTALLATION OR USE OF THIS APPLIANCE CAN CAUSE SERI­OUS INJURY OR DEATH FROM FIRE, BURNS, EXPLOSION OR CARBON MON­OXIDE POISONING.
Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning are similar to the flu with headaches, dizziness and/or nausea. If you have these signs, obtain fresh air immedi­ately. Turn off the gas supply to the appliance and have it serviced by a qualified profes­sional, as it may not be operating correctly.
WARNING: CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURES. USE CAUTION AROUND THE APPLIANCE TO AVOID BURNS OR CLOTHING IGNITION. YOUNG CHILDREN SHOULD BE CARE­FULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE.
WARNING: DO NOT PLACE CLOTHING OR OTHER FLAMMABLE MATERIALS ON OR NEAR THIS APPLIANCE.
AVERTISSEMENT: SURVEILLER LES ENFANTS. GARDER LES VÊTEMENTS, LES MEUBLES, L'ESSENCE OU AUTRES LIQUIDES À VAPEUR INFLAMMABLES LOIN DE L'APPAREIL.
OPERATION AND CARE OF YOUR APPLIANCE
Appliance operation may be controlled through a remotely located optional wall switch. Sepa­rate switches may provide independent con­trol for the remote controlled fireplace opera­tion (optional equipment). In lieu of remote or remote wall switch operation, the appliance must be operated directly through the controls located on the front of the valve located within the control compartment located behind the hinged drop down panel below the appliance front glass enclosure panel,
Figure 1
.
Gas Controls/Control Compartment Access
The gas controls can be found within the con­trol compartment behind the hinged drop-down control compartment access panel comprising the lower front face of the appliance below the front glass enclosure panel.
To open the control compartment access panel, actuate the spring loaded magnetic catches se­curing the door by gently depressing the outer top corners of the door until the catches "pop" the door free, allowing it to swing out and down to open. Once the control compartment door is opened, complete access to the gas control valve and its related controls is attainable.
To ease door closure, depress the catches to place them in their retracted position until they stay there, then close the door.
Operation of millivolt and electronic gas control systems are different. Before lighting and op­erating your appliance determine if you have a millivolt or electronic appliance.
ure 1
to access the control compartment. Mil-
livolt appliances will be fitted with the gas control valve shown in
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
Figure 2
Refer to Fig-
.
Appliances with electronic systems will be fit­ted with the electronic valve shown in Familiarize yourself with the differing controls for the valve your appliance uses.
SIT Gas Valve
Drop Down Control Compartment Access Panel
Sit and Honeywell Millivolt Gas Valve Showing
Piezo Ignitor Location (Each Unit is Equipped with
Piezo Ignitor
Only One of these Gas Valves)
Figure 3
Honeywell Gas Valve
Figure 1
Millivolt Appliances -
To light millivolt appliances refer to the detailed lighting instructions found in both English and French on tions respectively. Millivolt appliance lighting
instructions may also be found on the pull out lighting instruction labels attached to the gas control valve. Refer to
appropriate location for the piezo ignitor used with your appliance.
Millivolt appliances may be fitted with an op­tional ON/OFF Rocker Switch for appliance ON/ OFF control. The optional ON/OFF Rocker switch will be installed at either the right or the left side of the Piezo Ignitor on the Piezo Bracket, just beneath the valve. Once the pilot is lighted, the ON/OFF rocker switch will control the appliance ON/OFF operation. To operate: Toggle the switch between its ON and OFF positions.
If your millivolt appliance is equipped with an optional remote wall switch or remote control kit and the pilot is lit, the appliance main burner may be turned on and off with the wall switch or remote control.
Electronic Appliances -
To light electronic appliances refer to the de­tailed lighting instructions found in both En­glish and French on instructions respectively. Electronic appliance
lighting instructions may also be found on the pull out lighting instruction labels at­tached to the gas control valve. If your elec-
tronic appliance is equipped with an optional remote wall switch or remote control kit the appliance main burner may be turned on and off with the wall switch or remote control.
pages 12 and 13
Figure 2
pages 14 and 15
of these instruc-
to locate the
of these
.
3
If your electronic appliance is not equipped with a wall switch or remote control, the main burner must be turned off and on with the gas control switch. Toggle the switch from ON to OFF to operate the main burner .
OFF
ON
ON/OFF Switch
IN
PSI
Inlet Pressure Port
Electronic Gas Control Valve
Manifold Pressure Port
CONTROL
IG N
IT E
R
Honeywell Electronic Gas Valve
Figure 2
Variable Flame Height Adjustment
Manifold Pressure Port
TPTH TP TH
P
I
L
O
T
Optional Burner ON/OFF
Rocker Switch Location
Figure 3
I
H
L
W
O
Piezo Ignitor
Inlet Pressure Port
IN
OUT
F
F
O
P
I
L
it
O
T
O
N
Piezo Ignitor
Main Gas
Control Knob
Factory-Installed Blower ON/OFF
Rocker Switch Location
SIT Millivolt Gas Valve
Variable Flame Height Adjustment ( Millivolt Appliances only)
1. All Millivolt appliances are equipped with a
variable gas control valve. Flame height for these models may be adjusted through a range between fixed low and high settings, alter­nately, while the appliance is in operation. Ad­just the flame height as desired after lighting the appliance by rotating the variable adjust­ment control knob located on the front of the valve
(refer to Figure 3 - SIT, 4 - Honeywell)
2. When lit for the first time, this appliance will
emit a slight odor for an hour or two. This is due to the “burn-in” of internal paints and lubricants used in the manufacturing process.
3. Keep lower control compartment clean by vacuuming or brushing at least twice a year. More frequent cleaning may be required due to excessive lint from carpeting, bedding materi­als, etc. It is important that control compart­ments, burners and circulating air passage­ways of the appliance be kept clean.
4. Always turn off gas to the pilot (millivolt appliances) before cleaning. Before re-light­ing, refer to the lighting instructions in this manual. Instructions are also found on a pull­out panel located on the floor of the appliance.
5. Always keep the appliance area clear and free from combustible materials, gasoline and other flammable liquids.
6. Remember, Millivolt appliances have a con­tinuous burning pilot flame. Exercise caution when using products with combustible vapors.
Manifold Pressure Port
O
.
Variable Flame
Height Adjustment
Piezo Ignitor
O
L
H
I
L
Optional Burner ON/OFF
Rocker Switch Location
I
P
N
O
Figure 4
Glass Cleaning
It will be necessary to clean the glass periodi­cally. During start-up it is normal for conden­sation to form on the inside of the glass. This can cause lint, dust and other airborne par­ticles to cling to the glass surface. Also initial paint curing may deposit a slight film on the glass. It is therefore recommended that the glass be cleaned two or three times with a non­ammonia household cleaner and warm water (a gas fireplace glass cleaner is recommended). After that the glass should be cleaned two or three times during each heating season, de­pending on the circumstances present.
Note: Clean glass after first two weeks of operation.
WARNING: DO NOT USE ABRASIVE CLEANERS. NEVER CLEAN THE GLASS WHEN IT IS HOT.
Inlet Pressure Port
F
F
T
O
Piezo Ignitor
Optional ON/OFF Rocker Switch Main Gas Control Knob
Location (One of Two Places)
Honeywell Millivolt Gas Valve
CAUTION: DO NOT ATTEMPT TO TOUCH THE FRONT ENCLOSURE GLASS WITH YOUR HANDS WHILE THE FIREPLACE IS IN USE.
Maintenance
IMPORTANT: TURN OFF GAS AND ANY ELECTRICAL POWER BEFORE SERVICING THE APPLIANCE.
The appliance and venting system should be thoroughly inspected before initial use and at least annually by a qualified service techni­cian. However, more frequent periodic inspec­tions and cleanings should be performed by the homeowner. Homeowner must contact a
qualified service technician at once if any abnormal condition is observed.
Refer to the maintenance schedule for mainte­nance tasks, procedures, periodicity and by whom they should be performed. Always verify proper operation of the appliance after servicing.
4
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
Maintenance Schedule
Annually (Before the onset of the Burning Season)
Maintenance Task Accomplishing Person Procedure
Inspecting/Cleaning Burner, Logs and Controls
Check Flame Patterns and Flame Height
Inspecting/Cleaning Pilot and Burner
Checking Vent System
Appliance Checkout
Replacing Rockwool Ember Materials
Qualified Service Technician
Qualified Service Technician
Qualified Service Technician
Qualified Service Technician
Qualified Service Technician
Homeowner/Qualified Services Technician
Inspect valve and ensure it is properly operat­ing. Check piping for leaks. Vacuum the control compartment, fireplace logs and burner area.
Refer to
Figure 7
on page 7 and verify the
flame pattern and height displayed by the appliance conforms to the picture. Flames must not impinge on the logs.
Refer to
Figure 9 on page 7 (Electronic)
Figure 8 on page 7 (Millivolt) or
. Remove any surface build-up on pilot and burner assem­bly. Wipe the pilot nozzles, ignitor/flame rod and hood. Ensure the pilot flame engulfs the flame sensor as shown.
Inspect the vent system at the top and at the base (within the firebox) for signs of blockage or obstruction. Look for any signs of disloca­tion of the vent components.
Perform the appropriate appliance checkout procedure detailed in this manual.
Remove old ember materials and vacuum the screened rockwool placement area. Place new rockwool as described in this document.
Periodically (After the Burning Season)
Maintenance Task Accomplishing Person Procedure
Cleaning Firebox Interior
Check Flame Patterns and Flame Height
Checking Vent System
Cleaning Front Glass Enclosure Panel
Homeowner
Homeowner
Homeowner
Homeowner
Carefully remove logs, Rockwool and volcanic stone if used. Vacuum out interior of the firebox. Clean firebox walls and log grate. Replace logs, Rockwool and volcanic stone as detailed in this manual.
Refer to
Figure 7 on page 7
and verify the flame pattern and height displayed by the appliance conforms to the picture. Flames must not impinge on the logs.
Inspect the vent system at the top and at the base (within the firebox) for signs of blockage or obstruction. Look for any signs of disloca­tion of the vent components.
Clean as necessary following the directions provided in this manual. DO NOT TOUCH OR ATTEMPT TO CLEAN GLASS WHILE HOT.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
5
Front Glass Enclosure Panel, Removal and Installation.
WARNING: NEVER OPERATE THE AP­PLIANCE WITHOUT THE FRONT GLASS ENCLOSURE PANEL IN PLACE AND SE­CURE. DO NOT OPERATE APPLIANCE WITH FRONT GLASS CRACKED, BRO­KEN OR MISSING. REPLACEMENT MUST BE DONE BY A LICENSED OR QUALIFIED SERVICE TECHNICIAN.
These are direct-vent appliances. They are designed to operate only when the front glass enclosure panel is installed. Generally the front glass enclosure panel should not be removed except to gain access to the compo­nents within the firebox, and the appliance may only be operated without the front glass enclosure panel in place for very brief periods of time during appliance checkout and adjust­ment. Be sure that the flame appearance will be diminished while the front glass enclosure panel is removed.
WARNING: HANDLE THIS GLASS WITH EXTREME CARE! TEMPERED GLASS IS SUSCEPTIBLE TO DAMAGE – DO NOT SCRATCH OR HANDLE ROUGHLY WHILE REINSTALLING THE GLASS DOOR FRAME.
Top Flange Door Frame
Glass Door
Latch
Bottom Vee-flange
Door Frame
Figure 5
Latch
Firebox Floor
Refer to enclosure panel as follows:
1. Remove the top louver or radiant panel.
2. Open the hinged drop-down control com-
partment panel.
Figure 5
and remove the front glass
WARNING: NO NOT ATTEMPT TO SUB­STITUTE THE MATERIALS USED ON THIS DOOR, OR REPLACE CRACKED OR BRO­KEN GLASS WITH ANY MATERIALS OTHER THAN THOSE PROVIDED BY THE APPLIANCE MANUFACTURER.
THE GLASS DOOR OF THIS APPLIANCE MUST ONLY BE REPLACED AS A COMPLETE UNIT AS PROVIDED BY THE MANUFACTURER. DO NOT ATTEMPT TO REPLACE BROKEN, CRACKED OR CHIPPED GLASS SEPARATELY.
3. Locate the two (2) latches at the top of the
control compartment and disengage them from the door frame bottom Vee-flange, pulling down on their handles to open them.
4. Swing the bottom of the door out and raise it slightly to lift the top flange of the door frame away from the appliance.
To install the front glass enclosure panel, proceed as follows:
1. Retrieve the glass door frame. Visually
inspect the gasket on the backside of the panel. The gasket surface must be clean, free of irregularities and seated firmly.
2. Position the door frame in front of the firebox opening and engage the top flange over the lip at the top of the firebox opening.
3. Swing the door down and back. Ensure the gasket seats evenly as the door draws shut. Engage the Vee-flange at the bottom of the door with the latches and close the latches to secure the door.
4. Reinstall the top louver or radiant panel.
Burner Adjustments
The following paragraphs address burner ad­justment concerns and procedures.
Flame Appearance and Sooting
Proper flame appearance is a matter of taste. Generally most people prefer the warm glow of a yellow to orange flame. Appliances operated with air shutter openings that are too large will exhibit flames that are blue, transparent and much smaller than designed. These weak, blue and transparent flames are termed anemic. If the air shutter open­ing is too small sooting may develop.
Sooting is indicated by black puffs developing at the tips of very long orange flames. Sooting results in black deposits forming on the logs, appliance inside surfaces and on exterior sur­faces adjacent to the vent termination.
Sooting is caused by incomplete combustion in the flames and a lack of combustion air entering the air shutter opening. To achieve a warm yellow to orange flame with an orange body that does not soot, the shutter opening must be adjusted between these two extremes. No smoke or soot should be present. Reposition the logs if the flames impinge on any of them. If the logs are properly positioned and sooting conditions exist, the air shutter opening on the main burner tube should be adjusted. Nor­mally, the more elbows and horizontal runs there are in the vent system, the greater the need for the air shutter to be opened further.
WARNING: AIR SHUTTER ADJUSTMENT SHOULD ONLY BE PERFORMED BY A QUALIFIED PROFESSIONAL SERVICE TECHNICIAN.
ENSURE THAT THE FRONT GLASS PANEL IS IN PLACE AND SEALED DURING ADJUSTMENT.
Adjustment
CAUTION: THE ADJUSTMENT ROD AND NEARBY APPLIANCE SURFACES ARE HOT. EXERCISE CAUTION TO AVOID INJURY WHILE ADJUSTING FLAME APPEARANCE.
To adjust the flame, move the adjustment rod (located in the lower control area) up or down to increase or reduce the air shutter opening respectively. Initially, always position the air
shutter to the factory setting (the minimum air opening position as shown in
page 7
. This can be done by pulling the
adjustment rod all the way down.
Figure 6, on
6
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.