This installation manual will help you obtain a
safe,
efficient,
dependable installation for your
fireplace and vent system. Please read and
understand these installation instructions before beginning your installation.
INTRODUCTION
The DS-36R is a sealed combustion,
alr circu-
lating, gas appliance for residential applica-
tions. The unit is designed such that combus-
tion air (intake) is taken directly from outside
the structure while combustion gases are discharged to the outside.
The appliance must be installed on an
outslde
wall using a DSR-HTK Vent Termination Kit.
Extension pipe
andlor 45Vlbow sections ac-
commodate varying wall thickness
and
corner
1
(diagonal) installations.
Operation is achieved through an automatic
pilot valve with a millivolt operated relay and
piezo ignition system. No external electrical
power is required.
This appliance complies with National Safety
Standards and is tested and listed by Warnock
Hersey International
lnc. to ANSI
Z21.50b
-
1990 as a vented decorative gas appliance.
(In
Canada,CAN/CGA-2.22-M89.lR:41-1991
IR 643-1992, and CANICGA-2.17-M91).
2
1
Figure
1
NOTE DiAcRAMs 8 UusrnArIoUs UoT
To
SCALE
Installation must conform to local codes. In the
absence of local codes, installation must comply with the current National Fuel Gas Code,
3
ANSI 2223.1. 1992. (In Canada, the current
CAN-1
8149 installation code.)
Donotanempttoalterormoditytheconstmc-
tion of the fireplace or its components. Any
modification or aiteration may void the warranty, certification and approvals of this unit.
GENERAL INFORMATION
Note:
Installation
and repair should be
per-
formed
by a qualified sennce person.
The appiiance should be inspected annually by
a oualified orofessionai service oerson. More
frequent
lnipections and cleanings may
by
required due to excessive lint from carpeting,
bedding
material. etc.
It
is imperative that the
control compartment, burners and circulating
air passage ways
oftheappllance be keptclean.
Provide adequate clearances around air openings and adequate accessibility clearance for
service and proper operation. Never obstruct
the front openings of the appliance.
Thlsappliance 1s deslgned tooperateon natural
-
or propane gas only The use of other fuels or
comb~nat~on of fuels
will
degrade the perfor-
.
mance of thls system
Input of appliance is 21,000
BTUiHR for both
natural and propane gases.
A 118' NPT plugged tap is provided on the gas
control valveadjacent to the outlet to the main
burner for test gage connection.
Mtn~mum inlet gas pressure is4.5 incheswater
column for natural gas and 11
Inches water
column for propane for the purpose of input
adjustment.
Maximum inletgassupply pressure
is7.Oinches
water column for natural gas and 13.0 inches
water column for propane.
The appliance must be isolated from the gas
supply
plping system (by closing its individual
manual shut-off valve) during any pressure
testing of the gas supply
piplng system at test
pressures equal to or less than 112 psig (3.5
kPa).
The appliance and its individual shut-off vaive
must be disconnected from the gas supply
piping system during any pressure testing of
that system at test pressures in excess of 112
-'
psig
(3.5
kPa).