Superior DRC6340TEP, DRC6340TEN, DRC6345TEN, DRT6340TEP, DRT6345TEP Installation And Operation Instructions Manual

...
Page 1
USC
P/N 900343-01 Rev. C 11/2015
P900343-01
Installation and Operation Instructions
DRT/DRC6300 Series 40 and 45 in. Direct Vent Gas Fireplaces
Models
Ce manuel est disponible en francais, simplement en faire la demande. Numéro de la pièce 900343-03
INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.
PFS
Report No. F14-106
®
DRT6345TEN DRT6345TEP DRC6345TEN DRC6345TEP
DRT6340TEN DRT6340TEP DRC6340TEN DRC6340TEP
Installateur : Laissez cette notice avec l’appareil. Consommateur : Conservez cette notice pour consultation ultérieure.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
Cet appareil peut installé dans une maison préfabriquée (mobile) déjà installée à demeure, si les réglements locaux le permettent. Ce appareil doit être utilisé uniquement avec le type de gaz indiqué sure la plaque signalétique. Cet appareil ne peut être converti à d’autres gaz, sauf si une trousse de conversion est utilsée.
WARNING:
AVERTISSEMENT:
FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury, death, or property damage.
- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Leave the building immediately.
• If you cannot reach your gas supplier, call the fire department.
- Installation and service must be performed by a qualified installer, service agency or the gas supplier.
RISQUED’INDENDIE OU D’EXPLOSION Le non-respect Des avertissements de sécurité pourrait d’entraîner des blessures graves, la mort ou des dommages matériels.
- Ne pas entreposer ni utilizer d’essence ni d’autres vapeurs ou liquides inflammables dans le voisinage de cet appareil ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d’allumer d’appareil.
• Ne touchez à aucan interrupteur. Ne pas vous servir des téléphones se trouvant dans le bâtiment où vous trouvez.
• Sortez immédiatement de bâtiment.
• Appelez immédiatement votre fournisseur de gaz depuis un voisin. Suivez les instructions du fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz, appelez le service des incindies.
- L’installation et l’entretien doivent être assurés par un installateur ou un service d’entretien qualifié ou par le fournisseur de gaz.
Page 2
Innovative Hearth Products DRT/DRC6300 Series Direct-Vent Gas Fireplaces
SAFETY AND YOUR FIREPLACE
See attached color flyer for proper color representation
General Information 900343-01 11/2015
DANGER
A barrier designed to reduce the risk of burns from the hot viewing glass is pro­vided with this appliance and shall be installed for the protection of children and other at-risk individuals.
Voir ci-joint tract pour une bonne représentation de la couleur
DANGER
L’écran pare-étincelles fourni avec ce foyer réduit le risque de brûlure en cas de contact accidentel avec la vitre chaude et doit être installé pour la protection Des enfants et Des personnes à risques.
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
VITRE CHAUDE
RISQUE DE BRÛLURES.
NE TOUCHEZ PAS UNE VITRE
NON REFROIDIE.
NE LAISSEZ JAMAIS UN ENFANT
DE TOUCHER LA VITRE.
Vea el volante adjunto para la representación de color adecuado
PELIGRO
CAUSARÁ QUEMADURAS.
TOCAR EL VIDRIO CALIENTE.
LOS NIÑOS DEBEN NUNCA
Una barrera diseñada para reducir el riesgo de quemaduras desde la mirilla (vidrio) caliente es proveida con este aparato y deberá instalarse para la protección de los niños y otros individuos en riesgo.
2
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
EL VIDRIO CALIENTE
USTED DEBE NUNCA
TOCAR EL VIDRIO.
Page 3
Innovative Hearth Products DRT/DRC6300 Series Direct-Vent Gas Fireplaces
General Information 900343-01 11/2015
Safety and Your
Fireplace
All parts of your
IHP fireplace get
EXTREMELY HOT!
To prevent severe burns
and injuries, do Not remove the barrier on the appliance which prevents direct contact with the glass.
Follow the safety instructions below
and be sure everyone in your household understands this burn hazard:
• The surfaces on your fireplace get EXTREMELY HOT!
• The glass on the front of the fireplace reaches EXTREMELY HIGH temperatures and can cause severe burns if touched.
• Keep children away from an operating fireplace. Closely supervise children in any room where a fireplace is operating to prevent contact with glass.
• Keep clothing, furniture, gasoline, and other flammable liquids away from the fireplace.
• Even after the gas is turned off, fireplace surfaces remain extremely hot.
Be sure to attach the enclosed Safety-
in-Operation Warnings where you
turn on your fireplace, to help remind everyone of the dangers associated with high temperatures
Read Important Safety Information
(Page 5)
.
(Page 44)
.
La sécurité et
votre foyer
Toutes les parties de votre
foyer IHP deviennent
EXTRÊMEMENT CHAUDES !
Afin d’éviter les brûlures
graves ou les blessures, ne pas retirer l’écran de protection de la foyer qui empêche tout contact direct avec la vitre.
Suivez les instructions de sécurité
ci-dessous et veillez à ce que tous les membres de votre famille soient conscients du danger de brûlure encouru :
• Les surfaces de votre foyer deviennent EXTRÊMEMENT CHAUDES !
• La vitre située à l'avant du foyer atteint des températures EXTRÊMEMENT ÉLEVÉES et peut causer de graves blessures en cas de contact.
• Tenez les enfants à l'écart du foyer lorsqu'il fonctionne. Surveillez attentivement les enfants dans les pièces où un foyer est utilisé afin d'éviter qu'ils ne soient en contact avec la vitre.
• Tenez tous les vêtements, les meubles, l'essence et tout autre liquide inflammable à l'écart du foyer.
• Même après fermeture du gaz, les surfaces du foyer restent extrêmement chaudes.
Veillez à coller les Étiquettes de mise
en garde relatives à la sécurité d'utilisation à l'endroit où vous
utilisez le foyer, pour rappeler à tous les utilisateurs les dangers liés aux
températures élevées
Lisez L’information de sûreté importante (Page 5)
(Page 44)
.
.
Seguridad y su
chimenea
¡Todas las partes de la
chimenea IHP se ponen
MUY CALIENTES!
Para evitar quemaduras y lesiones
graves, no quite el protector de malla o guardia de seguridad que evita el contacto directo con el vidrio.
Siga las instrucciones de seguridad
a continuación y asegúrese de que todos en su hogar sepan acerca de este peligro de quemadura:
• ¡Las superficies de la chimenea se ponen MUY CALIENTES!
• El vidrio delante de la chimenea alcanza temperaturas EXTREMADAMENTE ALTAS y puede causar quemaduras graves si se toca.
• Mantenga a los niños alejados de la chimenea en funcionamiento. Supervise en forma cercana a los niños en cualquier cuarto donde haya una chimenea funcionando para impedir el contacto con el vidrio.
• Mantenga la ropa, mobiliario, gasolina y otros líquidos inflamables alejados de la chimenea.
• Aún después de haber apagado el gas, las superficies de la chimenea permanecen extremadamente calientes.
Asegúrese de colocar las Etiquetas de
advertencia de seguridad de operación
en el lugar donde enciende la chimenea, para que todos recuerden los peligros asociados con las altas temperaturas (Página 44)
Lea Información importante de
seguridad (Página 5).
.
[FRENCH][ENGLISH]
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
[SPANISH]
3
Page 4
Innovative Hearth Products DRT/DRC6300 Series Direct-Vent Gas Fireplaces
General Information 900343-01 11/2015
TABLE OF CONTENTS
Packaging ......................... 4
Introduction ........................ 4
General Information .................. 5
Massachusetts Requirements .......... 6
Cold Climate Insulation ............... 7
Manufactured Home Requirements ...... 7
Location . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Vent Termination Clearances ........... 8
Minimum Clearances to Combustibles ..... 10
Detailed Installation Steps ............. 11
Typical Installation Sequence .......... 11
Step 1. Framing .................... 11
Fireplace and Framing Specifications ...... 12
Step 2. Routing Gas Line ............. 13
Proper Sizing of Gas Line .............. 13
Step 3. Install the Vent System ........ 14
Vertical Termination Systems ........... 15
Vent Section Length Chart ............. 15
Vertical Vent Tables and Figures ......... 18
Horizontal Termination System ......... 19
Horizontal Vent Tables and Figures ...... 21
Step 4. Field Wiring ................. 23
Step 5. Removing Glass Door
Frame Assembly .................. 25
Step 6. Connecting Gas Line .......... 25
Step 7. Checking Appliance
Operation ........................ 25
Step 8. Installing Logs and Panels ...... 26
Step 9. Installing Glass Door .......... 28
Step 10. Burner Adjustments ........... 28
Finishing Requirements ............... 30
Step 11. Attaching Safety-in-
Operation Warnings ................ 31
Installation Accessories ............... 32
Gas Conversion Kits .................. 33
Operation And Care Of Your Appliance .... 35
Maintenance ........................ 40
Front Glass Enclosure Panel, Removal, and
Installation ....................... 41
Log, Volcanic Stone, and Glowing Ember
Placement ....................... 42
Burner Adjustments .................. 44
Flame Appearance and Sooting ......... 44
Burner Air Shutter Adjustment .......... 45
Electronic Appliance Checkout ......... 45
Ordering Replacement Parts ............ 46
Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Accessory Components ............... 47
Lighting Instructions ................. 49
Maintenance Schedule ................ 51
Troubleshooting Guide ................ 52
Replacement Parts List ............... 53
Warranty .......................... 55
4
Please read and understand these
instructions before beginning your
installation.
PACKAGING
The assembled fireplace is packaged with the following:
Literature Kit (plastic bag shipped in-
side firebox), containing Installation and Operation Manual (this manual), Safety Flyer, Glass and Barrier Flyer and Safety-in­Operation Warning Labels.
• One (1) bag Glowing Embers
• One (1) bag Platinum Embers
• One (1) bag Volcanic Stone
Remote Control and Wall Receiver
Switch Kit
Door Modesty Shield
Log Grate
NOTE: For use with fireplace as shipped from fac-
tory only. Not for use with Contemporary Burner/ Floor Kit.
REQUIRED ACCESSORIES
One of the following Firebox Liner Kits:
a. Ceramic Firebox Liner Kit–
Buff Rustic
b. Ceramic Firebox Liner Kit–
Red Rustic
c. Porcelain Firebox Liner Kit–
Black
d. Ceramic Firebox Liner Kit–
Red Herringbone
e. Ceramic Firebox Liner Kit–
Buff Herringbone
NOTE: Porcelain kits include side and back panels. Optional for use with log sets. Required when using the contemporary burner/floor kit.
NOTE:
• IF THE BARRIER BECOMES DAMAGED, THE BARRIER SHALL BE REPLACED WITH THE MANUFACTURER’S BARRIER FOR THIS APPLIANCE.
• FOR USE WITH BARRIER(S) PART NO(S). J7422 (40” MODELS) AND J7423 (45” MODELS).
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
INTRODUCTION
The DRT/DRC6300 Series direct-vent, sealed- combustion gas fireplaces operate on natural or propane gas. These appliances feature a remotely controlled electronic intermittent pilot ignition system (manual adjustment of the gas valve settings is not possible).
The DRT/DRC6300 Series is a decorative fire­place and may not be installed and operated as the primary heat source in a dwelling.
Electrical power (120 VAC line voltage) is rec­ommended to operate the fireplace; however, four (4) "AA" batteries can be used for full-time operation or as a backup in case of a power outage.
Approved Vent Components
These fireplaces are designed, tested, and listed for operation and installation with Secure
Vent® direct vent system components (8" inner,
11" outer) manufactured by Innovative Hearth Products.
These approved vent system components are labeled for identification. USE ONLY AP-
PROVED VENT COMPONENTS. Do NOT use any other manufacturer’s vent components with these appliances.
Codes and Standards
These appliances comply with National Safety Standards and are tested and listed by PFS Corporation (Report No. F14-106) to Z21.50 (in Canada, CSA-2.22), and CAN/CGA-2.17-M91 in both USA and Canada, as vented gas fireplaces.
These appliances are listed by PFS Corpora­tion for installation in bedrooms and mobile homes.
Installation must conform to local codes. In the absence of local codes, installation must comply with the current National Fuel Gas Code, ANSI Z223.1 (in Canada, the current CAN/CGA-B149.1 installation code).
The appliance, when installed, must be electri­cally grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70 (latest edition) or the Canadian Electrical Code, CSA C22.1 (latest edition).
Page 5
Innovative Hearth Products DRT/DRC6300 Series Direct-Vent Gas Fireplaces
General Information 900343-01 11/2015
GENERAL INFORMATION
WARNING
Young children should be care­fully supervised when they are in the same room as the appli­ance. Toddlers, young children and others may be susceptible to accidental contact burns. A physical barrier is recommended if there are at risk individuals in the house. To restrict access to a fireplace or stove, install an adjustable safety gate to keep toddlers, young children and other at risk individuals out of the room and away from hot surfaces.
AVERTISSEMENT
Les jeunes enfants devraient être surveillés étroitement lorsqu’ils se trouvent dans la même pièce que l’appareil. Les tout petits, les jeunes enfants ou les adultes peuvent subir des brûlures s’ils viennent en contact avec la sur­face chaude. Il est recommandé d’installer une barrière physique si des personnes à risques habi­tent la maison. Pour empêcher l’accès à un foyer ou à un poêle, installez une barrière de sécu­rité; cette mesure empêchera les tout petits, les jeunes enfants et toute autre personne à risque d’avoir accès à la pièce et aux surfaces chaudes.
Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid burns or clothing ignition.
Les enfants et les adultes devraient être infor-més des dangers que posent les températures de surface élevées et se tenir à distance afin d’éviter des brûlures ou que leurs vêtements ne s’enflamment.
DO NOT ATTEMPT TO ALTER OR MODIFY THE CONSTRUCTION OF THE APPLIANCE OR ITS COMPONENTS. ANY MODIFICATION OR ALTERATION MAY VOID THE WARRANTY, CERTIFICATION AND LISTINGS OF THIS UNIT.
WARNING
Improper installation, adjust­ment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a qualified installer, service agency or the gas supplier.
WARNING
Failure to comply with these installation instructions will result in an improperly installed and operating appliance, voiding its warranty. Any change to this appli­ance and/or its operating controls is dangerous.
WARNING
Clothing or other flammable material should not be placed on or near the appliance.
AVERTISSEMENT
On ne devrait pas placer de vêtements ni d’autres matières inflammables sur l’appareil ni à proximité.
WARNING
Any safety screen or guard removed for servicing the appli­ance must be replaced prior to operating the appliance.
AVERTISSEMENT
Tout écran ou protecteur retiré pour permettre l’entretien de l’appareil doit être remis en place avant de mettre l’appareil en marche.
WARNING
Improper installation or use of this appliance can cause serious injury or death from fire, burns, explosion or carbon monoxide poisoning.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
Installation and repair should be done by a qualified service person. The appliance should be inspected before use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding ma­terial, etcetera. It is imperative that control compartments, burners and circulating air passageways of the appliance be kept clean.
L’installation et la réparation devrait être confiées à un technicien qualifié. L’appareil devrait faire l’objet d’une in­spection par un technicien professionnel avant d’être utilisé et au moins une fois l’an par la suite. Des nettoyages plus fréquents peuvent être nécessaires si les tapis, la literie, et cetera produisent une quantité importante de pous-sière. Il est essentiel que les compartiments abritant les commandes, les brûleurs et les con­duits de circulation d’air de l’appareil soient tenus propres.
Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any parts of the control system and any gas control which have been under water.
Ne pas se servir de cet appareil s'il a été plongé dans l'eau, complètement ou en partie. Appeler un technicien qualifié pour inspecter l'appareil et remplacer toute partie du système de contrôle et toute commande qui ont été plongés dans l'eau.
Only trim kit(s) supplied by the manufacturer shall be used in the installation of this ap­pliance.
Seules les trousses de garniture fournies par le fabricant doivent être utilisées pour l’installation de cet appareil.
Provide adequate clearances around air open­ings and adequate accessibility clearance for service and proper operation. Never obstruct the front openings of the appliance.
These appliances are designed to operate on natural or propane gas only. The use of other fuels or combination of fuels will degrade the performance of this system and may be dangerous.
These appliances must not be connected to a chimney or flue serving a separate solid fuel burning appliance.
NOTICE
If the barrier becomes damaged, the barrier shall be replaced with the manufacturer’s barrier for this appliance.
5
Page 6
Innovative Hearth Products DRT/DRC6300 Series Direct-Vent Gas Fireplaces
General Information 900343-01 11/2015
These electronic appliances are remotely controlled and feature an electronic intermit­tent pilot ignition system or standing pilot. External electrical power is required to operate these units.
These electronic models come standard with a remotely-modulated gas valve; flame appear­ance and heat output cannot be controlled at the gas valve. The BTU Input for these appli­ances is shown in Table 1.
Input (BTU/HR)
Model Input (BTU/Hr)
Natural Gas
40 in. 32,000 to 50,000 45 in. 40,000 to 57,000
Propane Gas
40 in. 32,000 to 50,000 45 in. 43,000 to 56,000
Table 1
Gas Pressure—All Models
Appliance inlet and manifold gas pressure requirements are listed in Tables 2 and 3.
Inlet Gas Supply Pressure
Fuel # Minimum Maximum
Natural
Gas
Propane
5.5" WC
(1.37 kPa)
11.0" WC
(2.74 kPa)
10.5" WC
(2.61 kPa)
13.0" WC
(3.23 kPa)
Table 2
Manifold Gas Supply Pressure
Fuel # Low High
Natural
Gas
Propane
1.6" WC (.4 kPa)
6.3" WC
(1.57 kPa)
3.5" WC
(.87 kPa)
10.0" WC
(2.49 kPa)
Table 3
Test gauge connections are provided on the front of the gas control valve (identified IN for the inlet and OUT for the manifold side).
Propane tanks are at pressures that will cause damage to valve components. Verify that the tanks have step-down regulators to reduce the pressure to safe levels.
The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psi (3.5 kPa).
The appliance must be isolated from the gas supply piping system by closing its equipment shutoff valve during any pressure testing of the gas supply piping system at test pressures
equal to or less than 1/2 psi (3.5 kPa).
6
Orifice Sizes—Sea Level To High Altitude (All Models)
These appliances are tested and approved for installation at elevations of 0–4500 feet (0–1372 meters) above sea level, using the standard burner orifice sizes (marked with an asterisk (*) in Table 4). For elevations above 4500 feet, contact your gas supplier or qualified service technician.
Deration—At higher elevations, the amount of BTU fuel value delivered must be reduced by either:
• using gas that has been derated by the gas company; or
• changing the burner orifice to a smaller size as regulated by the local authorities having jurisdiction and by the (USA) National Fuel Gas Code NFPA 54/ANSI Z223.1—latest edition or, in Canada, the CAN/CGA-B149.1 codes—latest edition.
Install the appliance according to the regulations of the local authorities having jurisdiction and, in the USA, the National Fuel Gas Code NFPA 54 / ANSI Z223.1—latest edition or , in Canada, the CAN/CGA-B149.1- latest edition.
NOTE: Flame appearance will diminish 4% per thousand feet of altitude.
Burner Orifice Sizes
Elevation 0–4500 ft ( 0–1372 m)
Model
40"
Traditional
45"
40" CD
45" CD
Contemporary
Table 4
Nat.Gas
drill size (inches)
0.1405" (#28)*
• H2286
0.150" (#25)*
• J8001
0.1405" (#28)*
• H2286
0.150" (#25)*
• J8001
* Standard size installed at factory
• Part /Cat. Number
Propane
drill size (inches)
0.082" (#45)*
• J8002
0.086" (#44)*
• H2287
0.073" (#49)*
• H8807
0.073" (#49)*
• H8807
Gas Valve Diagram
The SIT Proflame gas valve is shown in Figure 1.
Green Wire
(From DFC Wire
Harness)
Manifold (Out)
Test Port
Inlet (In) Test Port
Wire
(From DFC Wire
Harness)
Main Gas Inlet
3/8" NPT
Figure 1—SIT Proflame Valve
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
In Canada - CAN/CGA-2.17-M91 (R2009) (high altitude):
THE CONVERSION SHALL BE CARRIED OUT BY A MANUFACTURER’S AUTHO­RIZED REPRESENTATIVE, IN ACCOR­DANCE WITH THE REQUIREMENTS OF THE MANUFACTURER, PROVINCIAL OR TERRITORIAL AUTHORITIES HAVING JURISDICTION AND IN ACCORDANCE WITH THE REQUIREMENTS OF THE CAN/CGA-B149.1 OR CAN/CGA-B149.2 INSTALLATION CODES.
COMMONWEALTH OF MASSACHUSETTS REQUIREMENTS
These appliances are approved for installation in the US state of Massachusetts if the following additional requirements are met:
• Install this appliance in accordance with Massachusetts Rules and Regulations 248 C.M.R. Sections 4.00 through 8.00.
• Installation and repair must be done by a plumber or gas fitter licensed in the Com­monwealth of Massachusetts.
• The flexible gas line connector used shall not exceed 36 inches (92 centimeters) in length.
• The individual manual shut-off must be a T-handle type valve.
Massachusetts Horizontal Vent Requirements In the Commonwealth of Massachusetts, hori­zontal terminations installed less than seven (7) feet above the finished grade must comply with the following additional requirements:
• A hard wired carbon monoxide detector with an alarm and battery back-up must be installed on the floor level where the gas fireplace is installed. The carbon monoxide detector must comply with NFPA 720, be ANSI/UL 2034 listed and be ISA certified.
Connect GTMS Wire Harness
Pressure Regulator Tower
Yellow Ground Wire (From DFC Wire Harness)
Page 7
Drywall
Top Of Fireplace Opening
Non-Combustible
HORIZONTAL VENT
VERTICAL VENT
HORIZONTAL VENT
VERTICAL VENT
Innovative Hearth Products DRT/DRC6300 Series Direct-Vent Gas Fireplaces
• A metal or plastic identification plate must be permanently mounted to the exterior of the building at a minimum height of eight (8) feet above grade and be directly in line with the horizontal termination. The sign must read, in print size no less than one-half (1/2) inch in size, GAS VENT DIRECTLY BELOW.
KEEP CLEAR OF ALL OBSTRUCTIONS.
COLD CLIMATE INSULATION
For cold climate installations, seal all cracks around your appliance with noncombustible material and wherever cold air could enter the room. It is especially important to insulate outside chase cavity between studs and under floor on which appliance rests, if floor is above ground level. Gas line holes and other openings should be caulked or stuffed with unfaced fiberglass insulation.
If the fireplace is being installed on a cement slab in cold climates, a sheet of plywood or other raised platform can be placed underneath to prevent cold transfer to the fireplace and into the room. It also helps to sheetrock inside surfaces and tape for maximum air tightness and caulk firestops.
When the unit is installed with one side flush with a wall, the wall on the other side of the unit must not extend beyond the front edge of the unit.
Cross Corner
Application
Room Divider
Application
Recessed
Application
Island
Application
General Information 900343-01 11/2015
Flat
Application
Application
Flat on Wall
MANUFACTURED HOME REQUIREMENTS
This appliance may be installed in an aftermar­ket permanently located, manufactured home and must be installed in accordance with the manufacturer's instructions.
Cet appareil peut être installé cómme du matéri-el d'origine dans une maison préfabriquée (É.U. seulement) ou mobile et doit être installé selon les instructions du fabricant.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, un­less a certified kit is used.
Cet appareil doit être utilisé uniquement avec le type de gaz indiqué sur la plaque signalétique. Cet appareil ne peut être con­verti à d'autres gaz, sauf si une trousse de conversion est utilisée.
CAUTION: Ensure that the cross members are not cut or weakened during installa­tion. The structural integrity of the manu­factured home floor, wall, and ceiling / roof must be maintained.
Figure 2—Typical Installation
CAUTION: This appliance must be ground­ed to the chassis of the manufactured home in accordance with local codes or in the absence of local codes, with the National Electrical Code ANSI / NFPA 70— latest edition or the Canadian Electrical Code CSA C22.1—latest edition.
LOCATION
In selecting the location, the aesthetic and functional use of the appliance are primary concerns. However, vent system routing to the exterior and access to the fuel supply are also important.
Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies (Figure 2).
En raison des températures élevées, l’appareil devrait être installé dans un endroit où il y a peu de circulation et loin
du mobilier et des tentures (Figure 2).
The location should also be free of electrical, plumbing or other heating/air conditioning ducting.
These direct-vent appliances are uniquely suited for installations requiring a utility shelf positioned directly above the fireplace. Utility shelves like these are commonly used for locating television sets and decorative plants.
Be aware that this is a heat producing ap­pliance. Objects placed above the unit are exposed to elevated temperatures.
Do not insulate the space between the appliance and the area above it (see Figure
7 on Page 10).
The minimum height from the base of the appliance to the underside of combustible materials used to construct a utility shelf in this fashion is shown in Figure 7 on Page 10.
The appliance must be mounted on a fully supported base extending the full width and depth of the unit. The appliance may be located on or near conventional construction materials. However, if installed on combustible materials, such as carpeting, vinyl tile, or other combustible material other than wood flooring, the appliance shall be installed on a metal or wood panel extending the full width and depth of the appliance.
7
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
Page 8
3"
(76 mm)
Termination Kit
Combustible Projection
greater than 2-1/2” in length
Horizontal Vent Termination Clearances
Combustible Projection
2-1/2” or less in length
24"
(610 mm)
Ventilated Or
Unventilated Soffit
12
X
Roof Pitch is X/12
2 FT MIN.
2 FT MIN.
Lowest
Discharge
Opening
H*
*H = MINIMUM HEIGHT FROM ROOF TO LOWEST DISCHARGE OPENING OF VENT
TERMINATION HEIGHTS FOR VENTS ABOVE
FLAT OR SLOPED ROOFS
Horizontal Overhang
Vertical
Wall
Vent
Termination
Storm Collar
Concentric
Vent Pipe
Flashing
1” (25.4 mm) Minimum Clearance to Combustibles
Innovative Hearth Products DRT/DRC6300 Series Direct-Vent Gas Fireplaces
VENT TERMINATION CLEARANCES
These instructions should be used as a guideline and do not supersede local codes in any way. Install vent according to local codes, these instructions, the current National Fuel Gas Code (ANSI-Z223.1) in the USA or the current standards of CAN/CGA-B149.1 in Canada.
Vertical Vent Termination Clearances
Terminate multiple vent terminations according to the installation codes listed above. Also see Figure 3.
Terminate single vent caps relative to building components according to Figures 3 and 4.
12”
(305mm)
Minimum
Vertical Vent Termination Clearances
The vent / air intake termination clearances above the high side of an angled roof is as shown in the following chart:
Figure 4
General Information 900343-01 11/2015
Termination Heights For Vents
Above Flat Or Sloped Roofs Ref. NFPA 54 / ANSI Z223.1
Roof Pitch * Feet * Meters
Flat to 6/12 1.0 0.3 6/12 to 7/12 1.25 0.38 7/12 to 8/12 1.5 0.46 8/12 to 9/12 2.0 0.61
9/12 to 10/12 2.5 0.76 10/12 to 11/12 3.25 0.99 11/12 to 12/12 4.0 1.22 12/12 to 14/12 5.0 1.52 14/12 to 16/12 6.0 1.83 16/12 to 18/12 7.0 2.13 18/12 to 20/12 7.5 2.29 20/12 to 21/12 8.0 2.44
Figure 3—Multiple Terminations
8
Horizontal Vent Termination Clearances
The horizontal vent termination must have a minimum of 3" (76 mm) clearance to any overhead combustible projection of 2-1/2" (64 mm) or less (see Figure 5). For projections exceeding 2-1/2" (64 mm), see Figure 5. For additional vent location restrictions refer to Figure 6 on Page 9.
See Figure 28 on Page 20 for the recess allowances, into exterior walls, of the square horizontal terminations.
Figure 5—Side Elevation View
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
Page 9
DE
V
X
V
= Vent terminal
= Air supply inlet
= Area terminal NOT permitted
= 9" U.S. (12" Canada)
A
G
X
V
= Vent terminal
= Air supply inlet
= Area terminal NOT permitted
Innovative Hearth Products DRT/DRC6300 Series Direct-Vent Gas Fireplaces
General Information 900343-01 11/2015
NOTE:
Local codes or regulations may require
different clearances.
Location of vent termination must NOT
interfere with access to electrical service.
= Vent terminal
V
= Area terminal NOT permitted
= Air supply inlet
X
= 9" U.S. (12" Canada)
D
Center Line of
Horizontal
Termination
36"
(91.4 cm)
Exterior Wall
D
36"
(91.4 cm)
Inside Corner
[DETAIL]
See Item “D” in table below.
Ventilated
Soffit
V
A
G
V
G
A
[DETAIL]
Inside Corner
H
B
V
F
L
V
Fixed Closed
Window
C
Operable
Window
B
X
V V
V
A
C
C
C
BB
B
J
M
I
MINIMUM CLEARANCES
Clearance Description US Installation Canadian Installation
A = Clearance above grade, veranda, porch,
deck, or balcony.
B = Clearance to window or door that may be
opened.
C = Clearance to permanently closed window. 9" (229 mm) recommended to prevent window
D = Vertical clearance to ventilated soffit
located above the terminal within a horizontal distance of 36" (91.4 cm)
from center line of terminal. E = Clearance to unventilated soffit. 24" (61 cm) 24" (61 cm) F = Clearance to outside corner. 5" (12.7 cm) 5" (12.7 cm) G = Clearance to inside corner. 24" (61 cm) 36" (91.4 cm) H = Clearance to each inside of center line
extended above meter/regulator assembly.
= Clearance to service regulator vent outlet. 3 ft (91.4 cm) 3 ft (91.4 cm)
I
J = Clearance to non-mechanical air supply
inlet to building or combustion air inlet to
any other appliance.
K = Clearance to mechanical air supply inlet. 3 ft (91.4 cm) above, if within 10 ft (3 m) horizontally. 6 ft (1.83 m) L = Clearance above paved sidewalk or paved
driveway located on public property. M = Clearance under veranda, porch, deck, or
balcony.
In accordance with the current ANSI Z223.1 / NFPA 54 National Fuel Codes (latest editions). In accordance with the current CAN/CGA-B149.1 Installation Code (latest editions). A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single-family dwellings and serves both dwellings. Only permitted if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor.
Figure 6 - Horizontal vent termination clearances for buildings with combustible and noncumbustible exteriors
18" (46 cm) 18" (46 cm)
6" (15.2 cm) for appliances < 10,000 BTU/hr (3kW),
9" (23 cm) for appliances > 10,000 BTU/hr (3kW) and < 50,000 BTU/hr (15kW),
12" (30 cm) for appliances > 50,000 BTU/hr (15kW).
condensation.
24" (61 cm) 24" (61 cm)
3 ft (91.4 cm) within a height of 15 ft above the meter/regulator assembly.
6" (15.2 cm) for appliances < 10,000 BTU/hr (3kW); 9" (23 cm) for appliances > 10,000 BTU/hr (3kW)
and < 50,000 BTU/hr (15kW);
12" (30 cm) for appliances > 50,000 BTU/hr (15kW).
7 ft (2.13 m) 7 ft (2.13 m)
18" (46.0 cm)   18" (46.0 cm)
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
6" (15.2 cm) for appliances < 10,000 BTU/hr (3kW),
12" (30 cm) for appliances > 10,000 BTU/hr (3kW) and < 100,000 BTU/hr (30kW),
36" (91 cm) for appliances > 100,000 BTU/hr (30kW). 12" (305 mm) recommended to prevent window
condensation.
3 ft (91.4 cm) within a height of 15 ft above the meter/regulator assembly.
6" (15.2 cm) for appliances < 10,000 BTU/hr (3kW); 12" (30 cm) for appliances > 10,000 BTU/hr (3kW)
and < 100,000 BTU/hr (30kW);
36" (91.4 cm) for appliances > 100,000 BTU/hr (30kW).
V
V
X
K
9
Page 10
17 in.
(432 mm)
14 in.
(356 mm)
8-1/4 in.
(210 mm)
45°
12 in.
(305 mm)
5 in.
(127 mm)
12 (305)
10 (254)
8 (203)
6 (152)
4 (102)
7
(178)
17
(432)
15
(381)
13
(330)
2 (51)
9
(229)
11
(279)
Innovative Hearth Products DRT/DRC6300 Series Direct-Vent Gas Fireplaces
MINIMUM CLEARANCES TO COMBUSTIBLES
The appliance is approved with zero clearance to combustible materials on all sides (as detailed in Table 5), with the following exception: When
the unit is installed with one side flush with a wall, the wall on the other side of the unit must not extend beyond the front edge of the unit. In addition, when the unit is recessed, the side walls surrounding
the unit must not extend beyond the front edge of the unit (see Figure 2).
APPLIANCE MINIMUM CLEARANCES*
Inches (millimeters)
Sides 1/2 (13), 0 (0) Spacers **
Top Spacers 0 (0)
Floor 0 (0) Back 1/2 (13), 0 (0) Spacers
Bottom of Appliance To Ceiling 69 (1743)
Vent 3 (76)
Top * / 1 (25.4) Sides & Bottom
SERVICE CLEARANCES Feet (meters)
Front 3 feet (0.9 meters)
Table 5
General Information 900343-01 11/2015
Combustible Shelf Height—
Top Vent—with 2 Feet Vertical Vent and One 90 Degree Elbow
Model Secure Vent
40 in. *84-1/16 (2135) 45 in. *89-1/16 (2252)
* Includes 3" clearance to combustibles (required above vent components)
Do not insulate the space between the appliance and the area above it.
Shelf Height
(see table)
Figure 7
Shelf Above Fireplace With Top Venting
Inches (millimeters)
®
2-1/2 ft (to centerline) Vertical Vent (minimum)
10
*NOTE: 3" (75 mm) above any horizontal/inclined vent component. **NOTE: See Page 10, Step 1 for clearance requirements to the nailing
flange located at each side of the unit and any screw heads adjacent to it. See Page 30 for hearth extension requirements.
NOTE: Attic insulation shield (H3908, see Page 10) must be installed when blown or loose-fill insulation is used, and is required for all attic installations.
Shelf Height
To provide for the lowest possible shelf surface, the venting attached to the top vent should be routed in a way to minimize obstructions to the space above the appliance. Do not insulate the space between the ap- pliance and the area above it (see Figure 7). The minimum height from the base of the appliance to the underside of combustible materials used to construct a utility shelf in this fashion is shown in Figure 7.
Wall Finishes / Surrounds / Mantels
NOTE: Combustible wall finish materials and/or surround materials must not be allowed to encroach the area defined by the appliance front face (black sheet metal). Never allow combustible materials to be positioned
in front of or overlapping the appliance face. See Figure 9 and Figure 51 on Page 30.
Non-combustible materials, such as surrounds and other appliance trim, may be installed on the appliance front face with these exceptions: they must not cover any portion of the removable glass panel.
Vertical installation clearances to combustible mantels vary according to the depth of the mantel. See Figure 8. Mantels constructed of non­combustible materials may be installed at any height above the appliance opening. Minimum clearance requirements include any projections such as shelves, window sills, mantels, etc. above the appliance.
NOTE: We recommend the use of high temperature paint (rated 175° F or higher) on the underside of the mantel.
Minimum clearance requirements include any projections such as shelves,window sills, mantels, etc. above the appliance.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
Figure 8
Combustible Materials Allowed In Shaded Area "Safe Zone"
Side Wall
Figure 9
Top of Appliance
Side Wall
MANTEL
MANTEL
MANTEL
MANTEL
MANTEL
MANTEL
Top View of
Fireplace
Minimum Distance to Protected Side Wall
Minimum Distance to Unprotected Side Wall
MANTEL
CLEARANCES
Inches (mm)
Fireplace
(side view)
Page 11
WARNING
Failure to position the parts in accordance with these diagrams or failure to use only parts specifi­cally approved with this appliance may result in property damage or personal injury.
AVERTISSEMENT
Risque de dommages ou de blessures si les pièces ne sont pas installées conformément à ces schémas et ou si des pièces autres que celles spécifiquement approuvées avec cet appareil sont
The typical sequence of installation is outlined below. However, each installation is unique and may result in variations to the steps described.
See the Page numbers references in the follow­ing steps for detailed procedures.
Step 1. (Page 11) Construct the appliance
framing. Position the appliance within the framing and secure with nailing brackets.
Step 2. (Page 13) Route gas supply line to the
right side.
Step 3. (Page 14) Install the vent system and
exterior termination.
Step 4. (Page 23) Connect 120 VAC electrical
power to the appliance receptacle.
Step 5. (Page 25) Remove glass door assem-
bly.
utilisées.
Step 6. (Page 25) Make connection to gas
TYPICAL INSTALLATION SEQUENCE
DETAILED INSTALLATION STEPS
The appliance is shipped with all gas controls and components installed and pre­wired.
1. Remove the shipping carton, exposing the front glass door on the valve access side.
2. Using a Phillips screwdriver, unfasten two (2) screws located at the top of the glass frame (see Figure 46 on page 28). Tilt the top of the glass frame away from the unit. Lift it carefully off the bottom door track and set the door aside, protecting it from inadvertent damage.
Framing
Front Standoff
Top front of fireplace
The hear shield is designed to protect framing. Step 1. Heat shield rests on top standoffs
Step 7. (Page 25) Verifying appliance opera-
Step 8. (Page 26) Install firebox liner panels,
OR contemporary burner/floor kit, porce-
Step 9. (Page 28) Install glass door assembly. Step 10. (Page 28) Adjust burner to ensure
Step 11. (Page 31) Attach safety in operation
supply.
tion.
logs, and glowing embers
lain panels, and media.
proper flame appearance.
warnings.
Framing
Step 1. FRAMING
Frame these appliances as illustrated in Figure 11 on Page 12, unless the appliance is to be installed in a corner. See Figure 12 on Page 13 for corner framing installations. All framing
details must allow for a minimum clearance to combustible framing members as shown in Table 5 on Page 10.
If the appliance is to be elevated above floor level, a solid continuous platform must be constructed below the appliance.
Headers may be in direct contact with the appliance top spacers but must not be sup­ported by them or notched to fit around them. All construction above the appliance must be self-supporting, DO NOT use the appliance for structural support.
A header heat shiled is taped to the top of the fireplace. Slide the heat shield into the framing and attach the heat shield using the screws in the standoff (see Figure 10).
The fireplace should be secured to the side framing members using the unit's nailing flanges—one top and bottom on each side of the fireplace front (see Figure 10). Use 8d nails or their equivalent.
Use Top Flange For 1/2” Thick Drywall
Front Of Fireplace
Use Center Flange For Flush Mount
Use Bottom Flange For 5/8” Thick Drywall
Left Side Front Corner of Fireplace Shown
(Right Side Requirements the Same)
Unit Being Secured By Its Nailing Flanges
To The Framing
NOTE: The nailing flanges, combustible members and screw heads located in areas directly adjacent to the nailing flanges, are EXEMPT from the 1/2” clear­ance to combustible requirements for the firebox outer wrapper. Combustible framing may be in direct contact with the nailing flanges and may be located closer than 1/2” from screw heads and the firebox wrapper in areas adjacent to the nailing flanges. Frame the opening to the exact dimensions speci­fied in the framing details of this manual.
Unit Being Secured by Its Nailing
Flanges to the Framing
Figure 10
Step 2. Affix shield with 5/16" hex screws into front standoff.
Installing the Heat Shield
Non-combustible board
Step 3. Heat shield will now protect framing from heat from flue.
11
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
Page 12
E
A
B
D
Top View
Front View
5-1/8 (130)
Right Side View
14-1/8 8-1/2” (216)
5-1/4” (133)
(359)
26-1/2
(673)
C
26
(660)
25-1/2
(648)
7
1/2 (13)
(178)
19-5/8
(498)
Gas Inlet
(This Side Only)
Electrical
Inlet
10-3/8 (264)
F
G
H
J
Framing should be constructed
of 2x4 or larger lumber.
A
B
C
8-1/2 (216)
13
(
330
)
VENT FRAMING TOP VENT WITH 2 FEET VERTICAL VENT AND ONE 90° ELBOW
Framing should be constructed
of 2x4 or larger lumber.
Inches (mm)
(660)
26
15
(
381
)
6-1/2 (165)
1/2 A
PIPE CENTERLINE
Innovative Hearth Products DRT/DRC6300 Series Direct-Vent Gas Fireplaces
Framing Dimensions
Model A B C
40 in.
in. 50-3/4 45 75-1/8
mm 1289 1143 1908
45 in.
in. 56-7/8 50 80-1/8
mm 1445 1270 2035
Thermal Efficiency (%)
Natural Gas
Model P4
40 in. 35.8 45 in. 51.2
Installation
900343-01 11/2015
Model
40 in.
45 in.
Figure 11—Fireplace and Framing Specifications
12
26-1/2
(673)
26
(660)
5-1/8 (130)
Diagrams, illustrations and photo­graphs are not to scale — consult installation instructions. Product
Fireplace Dimensions
A B C D E F G H J
in. 50-5/8 39-1/4 45 25-3/8 34 37-5/8 33-1/8 29-3/8 34-3/4
mm 1286 997 1143 645 864 956 841 746 883
in. 56-3/4 44-1/4 50 28-3/8 40-1/8 43-5/8 38-1/8 34-1/2 41
mm 1442 1124 1270 721 1019 1108 968 876 1041
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
designs, materials, dimensions, specifications, colors and prices are subject to change or discontinuance without notice.
Based on CSA P.4.1-09
Vent Size
Coaxial DV
Vent Size
Notes
8" Inner
11" Outer
Page 13
Right Side Front Corner Of Fireplace Framing
6-1/4”
(159 mm)
19-5/8”
(498 mm)
C
Back wall of chase/enclosure
(including any finishing materials)
D
A
B
Model
A B C D
40 in.
in. 50-5/8 83-5/8 59-1/8 41-7/8
mm 1286 2124 1502 1064
45 in.
in. 56-3/4 89-7/8 63-1/2 44-7/8
mm 1441 2283 1613 1140
Figure 12—Corner Framing with Square Termination (SV8HTS)
Step 2. ROUTING GAS LINE
Route a 1/2" (13 mm) gas line along the inside of the right side framing as shown in Figure
13. Gas lines must be routed, constructed and made of materials that are in strict accordance with local codes and regulations.
All appliances are factory-equipped with a flexible gas line connector and 1/2" shutoff valve. (See Step 6 on Page 24).
The incoming gas line should be piped into the valve compartment and connected in one of the two methods as shown in Figure 36 on Page 25.
Figure 13
Proper Sizing of Gas Line
Properly size and route the gas supply line from the supply regulator to the area where the appliance is to be installed per requirements outlined in the National Fuel Gas Code, NFPA 54—latest edition (USA) or CAN/ CGA-B149.1—latest edition (Canada).
Never use galvanized or plastic pipe. Refer to Table 6 for proper sizing of the gas supply line, if black iron pipe is being used. Gas lines must be routed, constructed and made of materials that are in strict accordance with local codes and regulations. We recommend that a qualified individual such as a plumber or gas fitter be hired to correctly size and route the gas supply line to the appliance. Installing a gas supply line from the fuel supply to the appliance involves numerous considerations of materials, protection, sizing, locations, controls, pressure, sediment, and more. Certainly no one unfamiliar and unqualified should attempt sizing or installing gas piping.
Schedule 40—Black Iron Pipe
Inside Diameter (Inches)
Schedule 40 Pipe
Length (feet)
0–10 1/2" 3/8"
10–40 1/2" 1/2"
40–100 1/2" 1/2" 100–150 3/4" 1/2" 150–200 3/4" 1/2"
Table 6
Natural
Gas
Propane
Gas
NOTES:
• All appliances are factory-equipped with a flexible gas line connector and 1/2" shutoff valve (see Figure 36 on Page 25).
• See Massachusetts Requirements on Page 6 for additional requirements for installations in the state of Massachusetts in the USA.
• The gas supply line should Not be connected to the appliance until Step 6 (Page 25).
• A pipe joint compound rated for gas should be used on the threaded joints. Ensure propane
resistant compounds are used in propane applications. Be very careful that the pipe
compound does not get inside the pipe.
• It is recommended to install a sediment trap in the supply line as close as possible to the appliance (see Figure 36 on Page 25).
• Check with local building official for local code requirements.
IMPORTANT: If propane is used, be aware that if tank size is too small (i.e. under 100 lbs, if this is the only gas appliance in the dwelling. Ref. NPFA 58), there may be loss of pressure, resulting in insufficient fuel delivery (which can result in sooting, severe delayed ignition or other malfunctions). Any damage resulting from an improper installation, such as this, is not covered under the limited warranty.
13
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
Page 14
RESTRICTOR
APPLIANCE VENT OUTLET
When vertically terminating the vent system above the roof, install a vent restrictor in the top vent of the fireplace outlet. Install the restrictor as shown from inside the unit, in the inner fireplace collar
Innovative Hearth Products DRT/DRC6300 Series Direct-Vent Gas Fireplaces
Installation
900343-01 11/2015
Step 3. INSTALL THE VENT SYSTEM
General Information These instructions should be used as a guide-
line and do not supersede local codes in any way. Install vent according to local codes, these instructions, the current National Fuel Gas Code (ANSI-Z223.1) in the USA or the current standards of CAN/CGA-B149.1 and
-B149.2 in Canada. Ensure clearances are in accordance with
local installation codes and the requirements of the gas supplier.
Dégagement conforme aux codes d'installation locaux et aux exigences du foumisseunde gaz.
Use only approved venting components. See Approved Vent Components on Page 4.
These fireplaces must be vented directly to the outside.
The vent system may not service multiple appliances, and must never be connected to a flue serving a separate solid fuel burning ap­pliance. The vent pipe is tested to be run inside an enclosing wall (such as a chase). There is no requirement for inspection openings in the enclosing wall at any of the joints in the vent pipe.
Installation of Vent Restrictor
A vent restrictor may be needed with this appliance. The restrictor is installed in the appliance top flue outlet as shown in Figure 14,
For vertical venting from 6 feet to 12 feet or more, from the top of the fireplace to the top of the termination, the installation of a vent restrictor is required.
If necessary, install a vent restrictor in the appliance flue outlet as shown in Figure 14. The vent restrictor is held in place by friction, only.
NOTE: The restrictor is included within the firebox.
Figure 14—Vent Restrictor Installation
Select Venting System—Horizontal or Vertical
With the appliance secured in framing, de­termine vent routing and identify the exterior termination location. The following sections describe vertical (roof) and horizontal (exterior wall) vent applications. Refer to the section relating to your installation. A list of approved
venting components is shown on Page 32.
14
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
Page 15
Termination
Flashing And Storm Collar
Firestop/Spacer
SV8 6/12/24/36/48 Vent Sections
40' Max
(12.2 M)
6' Min
(1.8 M)
1" (25 mm) Minimum Clearance to Combustibles
VERTICAL TERMINATION SYSTEMS (ROOF)
lanimoN
38
T
22
32
Hs
04
04
04
noitceSlanimoN )sehcni(htgneL
621426384
T O T A L
Q T Y
noitceSteN
)sehcni(htgneL
2/1-42/1-012/1-222/1-432/1-64
tneVfothgieHsnoitceStneVforebmuN
sehcnitf
44121100034
0515.21010034
5.451578.21110035
5.061573.31020035
5.271573.41000505
77157.41100506
38152.51010506
6815.51000044
5.091578.51100045
5.691573.61010045
5.502521.71011507
70252.71000606
5.112526.71100607
5.712521.81010607
5.922521.91001607
5.232573.91000055
73257.91100056
5.142521.02000707
6425.02100708 25212010708 46222001708 67232000808
97252.32000066
5.082573.32100809
5.382526.32100
067
5.982521.42010067
5.103521.52001067
5.013578.52000909
5135.621009001
5.523521.72000077
0335.72100078 63382010078
54357.82000 01001
5.943521.92100 01011
27313000088
5.673573.13100089
5.973526.13000 11011
5.814578.43000099
32452.531000901
56457.8300000101
See Figure 15 and Figures 23 through 25 on Page 18 and their associated Vertical Vent
Tables which illustrate the various vertical venting configurations that are possible for use with these appliances. Secure Vent
®
pipe applications are shown in these figures. A Vertical Vent Table summarizes each system’s minimum and maximum vertical and horizontal length values
5.4573.0100001
957.0200002
5152.1110002
that can be used to design and install the vent components in a variety of applications.
1257.1020002
The vertical vent system terminates through the roof. The minimum vent height above the roof and/or adjacent walls is specified in ANSI Z223.1—latest edition (In Canada, the current CAN/CGA-B149.1 installation code) by major building codes. Always consult your local codes for specific requirements. A general guide to follow is the Gas Vent Rule (refer to
Figure 4 on Page 8).
Vertical (Straight) Installation
(Figure 15)
Determine the number of straight vent sections required. 4-1/2" (114 mm), 10-1/2" (267 mm), 22-1/2" (572 mm), 34-1/2" (876 mm) and 46-1/2" (1181 mm) net section lengths are available (see Tables on this page and Page 32—Vent Sections). Plan the vent lengths so that a joint does not occur at the intersection of ceiling or roof joists. Refer to the Vent Section Length Chart.
Figure 15
5457.3002002
1552.4100012
7557.4001102
6652.5022004
9657.5000202 2761030
1857.6000112
095.7021014
3957.7000022 6981012
2015.8200024
80191003
4115.9020024
71157.9105006
6215.01001304
53152.11006006
8315.11000404
Table 7: Vent Section Length Chart
NOTE: Convert inches into metric equivalent measurement, as follows:
Millimeters (mm) = Inches x 25.4 Centimeters (cm) = Inches x 2.54 Meters (M) = Inches x .0254
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
htgneLnoitceS
621426
)sehcni(
noitceSteN
2/1-42/1-012/1-2
)sehcni(htgneL
tneVfothgie
sehcnitf
5.01578.0010001
5.91526.12100
5.22578.1001001
5.52521.2120003
5.13526.2030003
5.43578.2000101
5.73521.3111003
5.34526.3021003
5.64578.3000011
5.94521.4102003
5.55526.4012003
5.76526.5003003
5.37521.6100203
5.97526.6010203
5.19526.7002013
5.79521.8100023
5.301526.8000303
5.811578.9110305
5.031578.01101305
5.931526.11000033
5.241578.11100405
4
/1-4
/1-64
noitceStneVforebmuN
0
O T A L
Q T Y
3
Model Effective Length
SV8L6 4-1/2" SV8L12 10-1/2" SV8L24 22-1/2" SV8L36 34-1/2" SV8L48 46-1/2"
Table 8—Effective Vent Length
15
Page 16
Minimum
13”
(330 mm)
Minimum
13”
(330 mm)
Innovative Hearth Products DRT/DRC6300 Series Direct-Vent Gas Fireplaces
Installation
900343-01 11/2015
Vertical (Offset) Installation
Analyze the vent routing and determine the quantities of vent sections and number of elbows required. Refer to Vertical Vent Figures and Tables on Page 18 to select the type of vertical installation desired. Vent sections are available in net lengths of 4-1/2" (114 mm), 10-1/2" (267 mm), 22-1/2" (572 mm), 34-1/2" (876 mm) and 46-1/2" (1181 mm). Refer to the Vent Section Length Chart on Page 15 for an aid in select- ing length combinations. Elbows are available in 90° and 45° configurations. Refer to Figure 20 on Page 17 for the SV8 E45 and SV8 E90 elbow dimensional specifications.
Where required, a telescopic vent section (SV8LA) may be used to provide the installer with an option in installing in tight and confined spaces or where the vent run made up of fixed length pieces develops a joint in a undesirable location, or will not build up to the required length. The SV8LA Telescopic Vent Section has an effective length of from 1-1/2" (38 mm) to 6-3/4" (171 mm). The SV8LA is fitted with a dimpled end (identical to a normal vent section component) and a plain end with 3 pilot holes. Slip the dimpled end over the locking channel end of a standard SV8 vent component the required distance and secure with three screws.
Maintain a minimum 1" (25 mm) clearance to combustible materials for all vertical ele­ments. Clearances for all horizontal elements are 3" (76 mm) on top, 1" (25 mm) on sides and 1" (25 mm) on the bottom.
A. Frame ceiling opening—Use a plumb line
from the ceiling above the appliance to locate center of the vertical run. Cut and/or frame an opening, 13" x 13" (330 mm x 330 mm) inside dime nsions, about this center mark (Figure 16).
Roof Framing
Ceiling Framing
Plumb Bob
Figure 16
B. Attach vent components to appliance—Se- cure Vent
®
SV8 direct-vent system components are unitized concentric pipe components featuring positive twist lock connections (see
Figure 17).
All of the appliances covered in this document are fitted with collars having locking inclined channels. The dimpled end of the vent compo­nents fit over the appliance collar to create the positive twist lock connection.
Align the dimple (four places) of the upper vent section with the opening of the locking incline channel on the lower vent section or appliance col­lar. Twist vent component clockwise to engage and seal until arrow and
Arrow
Appliance Collar or Vent Section
dimple align.
Dimple
Locking Incline Channel
Connected Vent Sections
Arrow
Figure 17
To attach a vent component to the appliance collar, align the dimpled end over the collar, adjusting the radial alignment until the four locking dimples are aligned with the inlet of the four inclined channels on the collar (refer to Figure 17). Push the vent component against the collar until it fully engages, then twist the component clockwise, running the dimples down and along the incline channels until they seat at the end of the channels. The unitized design of the Secure Vent components will engage and seal both the inner and outer pipe without the need for sealant or screws. If desired a #6 x 1/2" screw may be used at the joint, but it is not required as the pipe will securely lock when twisted.
C. Attach vent components to each other—
Other vent sections may be added to the previously installed section in accordance with the requirements of the vertical vent figures and tables. To add another vent component to a length of vent run, align the dimpled end over the inclined channel end of the previously installed section, adjusting the radial alignment until the four locking dimples are aligned with the inlets of the four incline channels of the previous section.
Push the vent component against the previous section until it fully engages, then twist the component clockwise running the dimples down and along the incline channels until they seat at the end of the channels. This seating position
is indicated by the alignment of the arrow and dimple as shown in Figure 17.
D. Install firestop/spacer at ceiling—When
using Secure Vent, use SV8BF firestop/spacer at ceiling joists. If there is living space above the ceiling level, the firestop/spacer must be installed on the bottom side of the ceiling. If attic space is above the ceiling, the firestop/spacer must be installed on the top side of the joist.
Route the vent sections through the framed opening and secure the firestop/spacer with 8d nails or other appropriate fasteners at each corner. Remember to maintain 1" (25 mm)
clearance to combustibles, framing members, and attic or ceiling insulation when running vertical chimney sections. Attic insulation shield (H3908) is required and may be used to help maintain the clearances indicated here. See installation accessories on Page 32. The
gap between the vent pipe and a vertical firestop can be sealed with non-combustible caulking.
E. Support the vertical vent run sections—
NOTE: Proper venting support is very important. The weight of the vent must not be supported by the fireplace in any degree.
Support the vertical portion of the venting system every 8 feet (2.4 m) above the fireplace vent outlet.
Blocking
Support Straps (Plumber's tape)
8 feet (2.4 m)
Maximum
1" (25.4 mm) minimum clearance to combustibles
Figure 18
16
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
Page 17
C
D
One method of support is by utilizing field pro-
Storm Collar
vided support straps (conventional plumber's tape). Secure the plumber's tape to the framing members with nails or screws. Strap the tape around the vent, securing the ends of the tape to the framing. If desired, sheet metal screws #6 x 1/2" length may be used to secure the support straps to the vent pipe. See Figure 18
on Page 16.
F. Change vent direction to horizontal/inclined run—At transition from or to a horizontal/
inclined run, install the SV8 E45 and SV8 E90 elbows in the same manner as the straight vent sections. The elbows feature a twist section to allow them to be routed about the center axis of their initial collar section to align with the required direction of the next vent run element.
Twist elbow sections in a clockwise direction only so as to avoid the possibility of unlocking any of the previously connected vent sections.
See Figure 17 on Page 16 and Figure 19.
Framing Dimensions for Roof
Inches (millimeters)
Pitch C D
0/12
6/12
12/12
13"
(330 mm)
13"
(330 mm)
13"
(330 mm)
Figure 20—Roof Framing
13"
(330 mm)
15-1/2"
(394 mm)
20-1/2"
(541 mm)
K. Install the vertical termination—The final
step involves installation of the Vertical Termina­tion. Extend the vent sections to the height as shown in the "Vertical vent termination section" on Page 8. The SV8VTR Vertical Termination (Figure 22) can be installed in the exact same fashion as any other Secure Vent® section. Align the termination over the end of the previously installed section, adjusting the radial alignment until the four locking dimples of the termination are aligned with the inlets of the four incline channels of the last vent section. Push the ter­mination down until it fully engages, then twist the termination clockwise running the dimples down and along the incline channels until they seat at the end of the channels.
10"
(254mm)
Swivel Joint
(360° swivel)
SV8E45
(45° Elbow)
6"
(153mm)
Swivel Joint
(360° swivel)
SV8E90
(90° Elbow)
Figure 19
G. Continue installation of horizontal/inclined sections—Continue with the installation of the
straight vent sections in horizontal/inclined run as described in Step C. Install support straps every 3 ft (914 mm) along horizontal/inclined vent runs using conventional plumber’s tape.
See Page 19, Figure 26. It is very important that the horizontal/inclined run be maintained in
a straight (no dips), slightly elevated plane. The recommended incline is approximately 1/4" per foot (20 mm per meter) horizontal, in a direction away from the fireplace. The rise per foot run ratios that are smaller are acceptable all the way down to at or near level. Use a carpenter’s level to measure from a constant surface and adjust the support straps as necessary.
It is important to maintain the required clear­ances to combustibles: 1" (25 mm) at all sides for all vertical runs; and 3" (76 mm) at the top, 1" (25 mm) at sides, and 1" (25 mm) at the bottom for all horizontal/inclined runs.
H. Frame roof opening—Identify location for vent at the roof. Cut and/or frame opening per Roof Framing Chart (Figure 20).
I. Install the roof flashing—Extend the vent sections through the roof structure. Install the roof flashing over the vent section and posi­tion such that the vent column rises vertically (use carpenters level) (Figure 21). Nail along perimeter to secure flashing or adjust roofing to overlap the flashing edges at top and sides only and trim where necessary. Seal the top and both sides of the flashing with waterproof caulking.
J. Install the storm collar—Install the storm collar, supplied with the flashing, over the vent/ flashing joint (see Figure 21). Loosen the storm collar screw. Slide collar down until it meets the top of the flashing. Tighten the adjusting screw. Apply non-combustible caulking or mastic around the circumference of the joint to provide a water tight seal.
Storm
Flashing
Collar
Figure 21
Figure 22
If the vent system extends more than 5 feet (1.5 m) above the roof flashing, stabilizers may be necessary. Additional screws may be used at section joints for added stability. Guide wires may be attached to the joint for additional sup­port on multiple joint configurations.
17
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
Page 18
V
H
1
H
V
1
Ceiling Firestop/Spacer (SV8BF)
Wall Firestop/Spacer (SV8HF)
H
V
V1
Ceiling
Firestop/Spacer
(SV8BF)
40 feet (12.2 meters)
Maximum
6 feet (1.8 meters)
Minimum
Ceiling
Firestop/Spacer
(SV8BF)
Innovative Hearth Products DRT/DRC6300 Series Direct-Vent Gas Fireplaces
VERTICAL VENT FIGURES/TABLES
NOTES:
• Secure Vent the figures.
• It is very important that the horizontal/ inclined run be maintained in a straight (no dips), slightly elevated plane. The recommended incline is approximately 1/4" per foot (20 mm per meter) horizontal, in a direction away from the fireplace. The rise per foot run ratios that are smaller are acceptable all the way down to at or near level.
SV8BF (Secure Vent) firestop/spacer must
be used anytime vent pipe passes through a combustible floor or ceiling. SV8HF (Secure Vent) firestop/spacer must be used anytime vent pipe passes through a combustible wall.
Two 45º elbows may be used in place of one 90º elbow. The same rise to run ratios, as shown in the venting figures for 90º elbows, must be followed if 45º elbows are used.
®
(rigid vent pipe) is shown in
Installation
900343-01 11/2015
Table A
H Maximum
feet (meter) feet (meter)
10 (3.1) 2.5 (0.762) 15 (4.65) 3.5 (1.07) 20 (6.2) 4.5 (1.37)
+ H = 40 feet (12.4 meters) Max.
V + V V + V1 = 11 feet (3.3 meters) Minimum for 40 in. units V + V1 = 10.5 feet (3.2 meters) Minimum for 45 in. units
1
Example: If 20 feet of (H) horizontal vent run is needed, then 4-1/2 feet minimum of (V) vertical vent will be required.
A Vent Restrictor, as shown in Figure 14 on Page 14, must be used in this application.
V Minimum
A Vent Restrictor, as shown in Figure 17 on Page 12, may need to be used in this application
Figure 23—Top Vent—Straight
Figure 24—Top Vent—Two 90 Degree Elbows (Corner Framing with Square Termination (SV8HTS))
Table B
H + H
Maximum
1
feet (meter) feet (meter)
10 (3.1) 2.5 (0.762) 15 (4.65) 3.5 (1.06) 20 (6.2) 4.5 (1.37)
H + H1 = 20 feet (6.2 m) Max.
V + V1 + H + H1 = 40 ft. (12.4 m) Max.
V + V1 = 11 feet (3.3 meters) Min. for 40 in. units
V + V1 = 10.5 feet (3.2 meters) Min. for 45 in. units
V Minimum
A Vent Restrictor, as shown in Figure 14 on Page 14, must be used in this application.
Example: If 20 feet of (H+ H tal vent run is needed, then 4-1/2 feet minimum of (V) vertical vent will be required.
Figure 25—Top Vent—Three Elbows
) horizon-
1
18
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
Page 19
Vertical
Rise
SV8E90
Elbow
Horizontal / Inclined Run
SV8HTS Termination Shown
Firestop/Spacer
SV8 L6/12/24/36/48
Vent Sections
Support Bracket Spacing Every 3 ft (914 mm)
SV8HTS Termination Shown
Support
Brackets
Building
Support
Framing
Ceiling
Fireplace
Exterior Wall
Exterior Wall
2-1/2 Foot Vertical
Vent (min.)
HORIZONTAL (OUTSIDE WALL) TERMINATION SYSTEM
See Figures 26–31 and their associated Horizontal Vent tables that illustrate the vari­ous horizontal venting configurations that are possible for use with these appliances. Secure
®
Vent
pipe applications are shown in these Figures. A Horizontal Vent table summarizes each system’s minimum and maximum vertical and horizontal length values that can be used to design and install the vent components in a variety of applications.
The horizontal vent system terminates through an outside wall. Building Codes limit or prohibit terminating in specific areas. Refer to Figure 6
on Page 9 for location guidelines. Secure Vent SV8 direct-vent system compo-
nents are unitized concentric pipe components featuring positive twist lock connection, (refer to Figure 17 on Page 16). All of the appli­ances covered in this document are fitted with collars having locking inclined channels. The dimpled end of the vent components fit over the appliance collar to create the positive twist lock connection.
A. Plan the vent run. Analyze the vent routing and determine the types and quantities of sections required 4-1/2" (114 mm), 10-1/2" (267 mm), 22-1/2" (572 mm), 34-1/2" (876 mm) and 46-1/2" (1181 mm) net section lengths are available. It is recommended that you plan the venting so that a joint does not occur in the ceiling or roof joists. Allow for elbows as indicated in Figure 20 on Page 17.
Maintain a minimum 1" (25 mm) clearance to combustibles on the vertical sections. Clearances for the horizontal runs are; 3" (76 mm) on top, 1" (25 mm) on sides, and 1" (25 mm) at the bottom.
B. Frame exterior wall opening—Locate the
center of the vent outlet on the exterior wall according to the dimensions shown in Figure 11 on Page 10. Cut and/or frame an opening, 15" x 13" (381 mm x 330 mm) inside dimen­sions, with 9" above center and 7" below center.
C. Frame ceiling opening—If the vertical route is to penetrate a ceiling, use plumb line to locate the center above the appliance. Cut and/or frame an opening, 13" x 13" (330 mm x 330 mm) inside dimensions, about this center (refer to Figure 17 on Page 16).
D. Attach vent components to appliance—To attach a vent component to the appliance collar, align the dimpled end over the collar, adjust­ing the radial alignment until the four locking dimples are aligned with the inlets of the four incline channels on the collar (refer to Figure
16 on Page 16).
Support the vertical portion of the venting system every 8 feet (2.4m) above the fireplace vent outlet.
Figure 26—Typical Horizontal Vent Installation
Push the vent component against the collar until it fully engages, then twist the component clockwise, running the dimples down and along the incline channels until they seat at the end of the channels. The unitized design of the Secure Vent components will engage and seal both the inner and outer pipe elements with the same procedure. Sealant and securing screws are not required.
E. Attach vent components to each other—
Other vent sections may be added to the previ­ously installed section in accordance with the requirements of the vent tables. To add another vent component to a length of vent run, align the dimpled end of the component over the inclined channel end of the previously installed section, adjusting the radial alignment until the four locking dimples are aligned with the inlets of the four incline channels of the previous section. Push the vent component against the previous section until it fully engages, then twist the component clockwise running the dimples down and along the incline channels until they seat at the end of the channels. This
seating position is indicated by the alignment of the arrow and dimple as shown in Figure
17 on Page 18.
F. Install firestop/spacer at ceiling—When using Secure Vent, use SV8BF firestop/spacer at ceiling joists. If there is living space above the ceiling level, the firestop/ spacer must be installed on the bottom side of the ceiling. If attic space is above the ceiling, the firestop/ spacer must be installed on the top side of the joist. Route the vent sections through the framed opening and secure the firestop/spacer with 8d nails or other appropriate fasteners at each corner.
Remember to maintain 1" (25 mm) clearance to combustibles, framing members, and attic or ceiling insulation when running vertical chimney sections.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
G. Support the vertical run sections—See
Step E on Page 18.
H. Change vent direction—At transition from or to a horizontal/inclined run, install the SV8E45 and SV8E90 elbows in the same manner as the straight vent sections. The elbows feature a twist section to allow them to be routed about the center axis of their initial collar section to align with the required direction of the next vent run element. Twist elbow sections in a clockwise
direction only so as to avoid the possibility of unlocking any of the previously connected vent sections (see Figure 17 on Page 18).
I. Continue installation of horizontal/inclined sections—Continue with the installation of the
straight vent sections in horizontal/inclined run as described in Step E on Page 16. Install support straps every 3 feet (1914 mm) along horizontal/inclined vent runs using conventional plumber’s tape.
See Figure 26, It is very important that the
horizontal/inclined run be maintained in a straight (no dips), slightly elevated plane. The recommended incline is approximately 1/4" per foot (20 mm per meter) horizontal, in a direction away from the fireplace. The rise per foot run ratios that are smaller are acceptable all the way down to at or near level.
It is important to maintain the required clear­ances to combustibles: 1" (25 mm) at all sides for all vertical runs; and 3" (76 mm) at the top, 1" (25 mm) at sides, and 1" (25 mm) at the bottom for all horizontal/inclined runs.
Use a carpenter’s level to measure from a constant surface and adjust the support straps as necessary.
19
Page 20
Siding
Stucco
1-1/4” Maximum Recess of Square Termination into Exterior Finishing Material
Exterior Surface of
Framing
5” to 8-1/2”
(127 to 216 mm)
Exterior Surface of Siding
Minimum wall thickness
5” (127 mm)
Interior Surface of
Finished Wall
Maximum wall thickness
8-1/2” (216 mm)
SV8HTS
Square Termination
shown
Maximum Extent of Vent Run Sections to Exterior Surface of Framing
Last Vent Section. Use Telescopic Vent Section (SV8LA), If Necessary
Adaptor
SV8RCH
SV8HTS
Square Termination
Shown
Venting Connection and Exterior Wall Recessing
of the Horizontal Square Termination (SV8HTS).
Innovative Hearth Products DRT/DRC6300 Series Direct-Vent Gas Fireplaces
Installation
900343-01 11/2015
J. Assemble vent run to exterior wall—If not previously measured, locate the center of the vent at the exterior wall. Prepare an opening as described in Step B on Page 19. Assemble the vent system to point where the terminus of the last section is within 5" (127 mm) to 8-1/2" (216 mm) inboard of the exterior surface to which the SV8HTS termination is to be attached, see Figure 29 and Table 9 on Page 21.
If the terminus of the last section is not within this distance, use the telescopic vent section SV8LA, as the last vent section. For wall thick­nesses greater than that shown in Figure 28, refer to Table 9 on Page 21. This table lists the additional venting components needed (in addition to the termination and adaptor) for a particular range of wall thicknesses.
K. Attach termination adaptor—Attach the adaptor (adaptor—SV8RCH—provided with the termination) to the vent section or telescoping vent section), or elbow as shown in Figure 27 in the same manner as any SV vent component (refer to Step E on Page 19).
L. Install Firestop/Spacer at exterior wall —When using the square termination, install
SV8HF Firestop/Spacer over the opening at the exterior side of the framing, long side up, with the 3" spacer clearance at the top as shown in Figure 27, and nail into place.
To help minimize water infiltration it is recommended that the Firestop/
To help minimize water infiltration
Spacer (SV8HF) be installed on the
install the Firestop/Spacer (SV8HF)
exterior side of the wall.
on the exterior side of the wall.
8-1/2”
15”
(381 mm)
(165 mm)
Adaptor
SV8RCH
6 to 48” Vent Section,
Telescopic vent section.
(216 mm)
6-1/2”
13”
(330mm)
NOTE: Centerline of Vent Piping is NOT the Same as the Centerline of the Framed Opening.
See Figure 11 on Page 12 for Minimum Distance to Base of Appliance
Base of Appliance
1”
(25 mm)
(25 mm)
Figure 27—Installing the Square Horizontal Termination (SV8HTS)
1”
SV8HTS
Termination
Shown.
3”
(76 mm)
u
(The Firestop/Spacer may also be installed over the opening at the interior side of the framing).
M. Install the square termination (SV8HTS)— For the last step, from outside the exterior wall, slide the collars of the termination onto the adaptor (the outer over the outer and the inner inside the inner) until the termination seats against the exterior wall surface to which it will be attached. Orient the housing of the termination with the arrow pointed upwards. Secure the termination to the exterior wall. The
horizontal termination must not be recessed into the exterior wall or siding by more than the 1-1/4" (32 mm) as shown in Figure 28.
IMPORTANT: The vent termination is hot while in operation and for a period of time following the use of the fireplace. Young children should be carefully supervised when they are in the same area as a hot termination.
20
For wall thicknesses greater than
u
Figure 28—Wall Thickness and Horizontal Termination Requirements
Horizontal terminations have been designed to perform in a wide range of weather condi­tions. Our terminations meet or exceed industry standards.
When selecting the locations of your horizontal terminations, do not place the termination where water from eaves and adjoining rooflines may create a heavy flow of cascading water
8-1/2", see Table 9
onto the termination cap. If the cap must be placed where the possibility of cascading water exists, it is the responsibility of the builder to direct the water away from the termination cap by using gutters or other means.
Take care to carefully follow the installation instructions for the termination, including the use of silicone caulking where required.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
Page 21
See Table 9 as an aid in venting component selection for a particular
H
V
Wall Firestop/Spacer
(SV8HF)
Ceiling
Firestop/Spacer
(SV8BF)
range of exterior wall thicknesses.
Venting Components Required for Various Exterior
Wall Thicknesses, when using Square Termination Kit
(SV8HTS—see Figure 28)
Vent Components Required Exterior Wall Thickness—inches (mm)
Termination Kit Only 5 to 8-1/2 (127 to 216) Termination Kit and 6" Vent
Section (SV8L6) Termination Kit and Tele-
scopic Section (SV8LA) Termination Kit and Tele-
scopic Section (SV8LA) and
9-3/4 to 14 (248 to 356)
6-3/4 to 15-1/4 (171 to 387)
11-1/4 to 19-3/4 (286 to 502)
6" vent section (SV8L6)
Table 9
HORIZONTAL VENT FIGURES/TABLES
NOTES:
• Secure Vent
in the figures.
Two 45º elbows may be used in place of one 90º elbow. The same rise
to run ratios, as shown in the venting figures for 90º elbows, must be followed if 45º elbows are used.
SV8BF (Secure Vent) firestop/spacer must be used anytime vent pipe
passes through a combustible floor or ceiling. SV8HF (Secure Vent) firestop/spacer must be used anytime vent pipe passes through a combustible wall.
• It is very important that the horizontal/inclined run be maintained in a straight (no dips), slightly elevated plane. The recommended incline is approximately 1/4" per foot (20 mm per meter) horizontal, in a direction away from the fireplace. The rise per foot run ratios that are smaller are acceptable all the way down to at or near level.
®
components (rigid vent pipe and terminal) are shown
Example: If 20 feet of (H) horizontal vent run is needed, then 10 feet minimum of (V) vertical vent will be required.
H Maximum
Table C
V Minimum
feet (meter) feet (meter)
3.5 (1.07) 2.5 (0.762)
6.5 (1.98) 3.5 (1.07)
8.5 (2.6) 4.5 (1.37)
10.5 (3.2) 5.5 (1.68)
12.5 (3.8) 6.5 (1.98)
14.5 (4.4) 7.5 (2.3)
16.5 (5.0) 8.5 (2.6)
18.5 (5.6) 9.5 (2.9) 20 (6.0) 10 (3.0)
V + H = 40 feet (12.4 m) Max.
H = 20 ft. (6.2 m) Max.
Square termination (SV8HTS) shown.
See Table 9 as an aid in venting component selection for a particular range of exterior wall thicknesses.
Figure 29—Top Vent—One 90 Degree Elbow (Elbow Connection Not Directly at Appliance)
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
21
Page 22
V
H
H
1
Wall Firestop/Spacer
(SV8HF)
Wall Firestop/Spacer
(SV8HF)
Ceiling
Firestop/Spacer
(SV8BF)
V
H
H
1
V
1
Wall Firestop/Spacer
(SV8HF)
Ceiling
Firestop/Spacer
(SV8BF)
Wall
Firestop/Spacer
(SV8HF)
Ceiling
Firestop/Spacer
(SV8BF)
Innovative Hearth Products DRT/DRC6300 Series Direct-Vent Gas Fireplaces
HORIZONTAL VENT FIGURES/TABLES
(continued)
See Table 9 on Page 21 as an aid in venting component selection for a particular range of exterior wall thicknesses.
Installation
900343-01 11/2015
Table D
H
+ H
1
Maximum
V Minimum
feet (meter) feet (meter)
3.5 (1.07) 2.5 (0.762)
6.5 (1.98) 3.5 (1.07)
8.5 (2.6) 4.5 (1.37)
10.5 (3.2) 5.5 (1.68)
12.5 (3.8) 6.5 (1.98)
14.5 (4.4) 7.5 (2.3)
16.5 (5.0) 8.5 (2.6)
18.5 (5.6) 9.5 (2.9) 20 (6.0) 10 (3.0)
V + H + H1 = 40 feet (12.4 m) Max.
H + H
= 20 ft. (6.2 m) Max.
1
Figure 30—Top Vent—Two 90 Degree Elbows
Table E
H
+ H1 = 20 feet (6.2 m) Max.
V + V
+ H + H1 = 40 ft. (12.4 m) Max.
1
V = 2.5 feet Min. (0.762 m)
V + V
= 11 feet (3.35 m) Min. for 40 in. units
1
V + V
= 10.5 feet (3.2 m) Min. for 45 in. units
1
22
See Table 9 on Page 21 as an aid in venting component selection for a particular range of exterior wall thicknesses.
Figure 31—Top Vent—Three 90 Degree Elbows
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
Page 23
Pilot Tube
Spark Electrode
Flame Sensor
IPI Pilot
885 Valve
BL
W
Y
Y
BR
G
O
O
R
R
B
B
G
GY
R
B
BL
WH
B
B
W
G
Battery Holder w/Switch ON/ Remote /OFF
Battery Holder Wire Harness
Reset Switch
(See instructions.)
Power Vent Blower
Power Vent
Models Only
Air Pressure Switch
Power Vent Only
Note: On models without pressure
switch, these
connectors are
plugged together.
Main Wire
Harness
Main Power Cord
Control Module
G
B
G
W
B
Fuse
ELECTRONIC WIRING DIAGRAM
Ground Y
B
Battery Holder with Switch
ON/Remote/OFF
(Schematic representation only)
COLOR CODE: B = Black BB = Brown w/Black Stripe BG = Brown w/Green Stripe BL = Blue BR = Brown G = Green GY = Gray O = Orange R = Red W = White Y = Yellow
Step 4. FIELD WIRING
J-BOX/RECEPTIACLE
WIRING
120V, 60HZ, 1PH
Factory Wired
Field Wired
Junction Box
Tab Intact
Tab Intact
n e e r G - d n u o r G
e t i h W - l a r
t u e N
120 VAC - Black
Green Ground Screw
White
Green
Neutral Side of Receptacle
Hot Side of Receptacle
Black
Red
CAUTION
Ground supply lead must be con­nected to the wire attached to the green ground screw located on the outlet box. Failure to do so will result in a potential safety hazard. The appliance must be electrically grounded in accordance with local codes or, in the absence of local codes, the National Electrical Code, ANSI/NFPA 70-latest edition. (In Canada, the current CSA C22-1 Cana dian Electrical Code).
CAUTION: Label all wires prior to disconnec­tion when servicing controls. Wiring errors can cause improper and dangerous operation.
ATTENTION: Au moment de l commandes, étiquetez tous les fils avant de les débrancher. Des erreurs de cáblage peuvent entraîner un fonctionnement inadéquat et dangereux.
entretien des
-
Verify proper operation after servicing.
S’assurer que l’appareil fonctionne adéquatement une fois l’entretien terminé.
The gas valve is set in place and pre-wired at the factory.
Electronic Wiring
NOTE: The electronic appliance must be connected to the main power supply.
1. Route a 3-wire 120Vac 60Hz 1ph power
supply to the appliance junction box.
2. Remove the electrical inlet cover plate from
the side of the unit by removing the plate's securing screws (see Figure 11 on Page 12).
3. Remove the cover plate's knockout and then
feed the power supply wire through the knock­out opening and into the unit junction box.
4. Connect the black power supply wire to the power outlet's red pigtail lead and the white
power supply wire to the common terminal of the outlet as shown in Figures 32 and 33.
5. Connect the ground supply wire to the pig­tail lead attached to outlet's green ground screw.
6. Install the wall-mounted ON/OFF control, as
described in "Installing and initializing the Remote Control System" on Page 24, in a convenient location near the fireplace.
7. After the wiring is complete, replace the
cover plate.
Figure 33—J-BOX WIRING
A wiring diagram is provided here for reference purposes only. This information is also provided on schematics attached directly to the appliance on a pullout panel located within the control compartment.
Figure 32
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
23
Page 24
Innovative Hearth Products
Hot Fireplace Will Cause
Severe Burns
Never Allow Children to Touch Glass or other Fire-
place Parts
WARNING
DRT/DRC6300 Series Direct-Vent Gas Fireplaces
Installation
900343-01 11/2015
Installing and initializing the Remote Control System
REQUIRED ITEMS (not provided):
• Standard Junction Box
• Paper Clip or similar object (for remote control system initialization)
Installing and Wiring the Receiver (Wall Switch)
The receiver for the Total Comfort Control™ Remote Control System connects directly to the gas valve, stepper motor, and fan control module with an umbilical cord wiring harness.
1. Install a junction box (not provided) on the wall adjacent to the appliance, within reach of the remote system umbilical cord wiring harness. Position the 6-pin termi­nal within the junction box in preparation for attachment to the remote receiver.
2. When wall finish is complete, install the receiver in the previously installed junc­tion box, and connect the 6-pin terminal to the 6-pin connector on the back of the receiver.
3. Install the receiver cover plate, taking care to ensure the receiver switch is properly indexed with the switch cover when align­ing the components for attachments.
Initializing the Remote Control System
After completing fireplace installation, initialize the remote control system before operating the fireplace.
4. Insert the three (3) provided AAA batteries into the battery bay in the transmitter, tak­ing care to correctly align polarity (+/ - ).
5. Insert the four (4) provided AA batteries into the receiver battery bay (behind the wall switch plate), taking care to correctly align polarity (+/ - ).
6. On the receiver, place the three-position slider switch in the REMOTE position
(Figure 34).
7. On the receiver front cover, insert the end of a paper clip (or other similar object; not provided) into the hole marked “PRG.”
The receiver will “beep” three times to
indicate it is ready to synchronize with the transmitter.
8. On the transmitter, press the ON button. The receiver will “beep” four times to indicate acceptance of the transmitter’s command (and set the receiver to the transmitter’s specific code). The system is now initialized.
The remote control system provides remote operation of the following fireplace functions:
• Primary burner ON/OFF
• Flame height and heat output adjustment (six levels)
The receiver accepts commands via radio frequency from the transmitter and does not require line-of-sight operation.
The slider switch on the receiver can be set to one of three positions:
• ON (manual override)
• OFF (manual override)
• REMOTE (remote control)
See the fireplace Care and Operation Instruc­tions for detailed instructions on using the remote control system to operate the fireplace.
Three-position slider switch in REMOTE position
On
Remote
Off
PRG
Figure 34—Receiver (Wall Switch)
LCD Display
ON/OFF Key
ROOM TEMP. Key
UP/DOWN Arrow Key
MODE Key
Figure 35—Transmitter (Remote Control)
WARNING
Fire hazard. Can cause severe injury or death. The receiver causes ignition of the appliance. The appliance can turn on suddenly. Keep away from the appliance burner when operating the remote system or activating manual bypass of the remote system.
CAUTION
Property damage hazard. Exces­sive heat can cause property damage. The appliance can stay lit for many hours. Turn off the appliance if it is not going to be attended for any length of time. Always place the transmitter where children can not reach it.
24
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
Page 25
Step 5. REMOVE GLASS DOOR FRAME
Gas Valve
Access Plate
Right Side
Modesty Panel
Gas Valve
3/8" NPT x
Flare Fitting
3/8" Flex Tubing
3/8" Nipple
3/8" Union
3/8" Close Nipple
3/8" Shut-off Valve
1/2" x 3/8"
Reducer
Gas
Stub
1/2" x 3/8" Flare
Shut-off Valve
Gas Solid Line Connector
Gas Flex Line Connector
*Sediment Trap
3"
Min
Igniter
Remove the glass door assembly. See Installa­tion and Removal of Glass Door on Page 28.
Step 6. CONNECTING GAS LINE
All codes require a shut-off valve mounted in the supply line. The orientation of the shut-off valve should face the front. Figure 36 illustrates two methods for connecting the gas supply. A Sedi­ment Trap is recommended to prevent moisture and debris in gas line from damaging the valve.
The flex-line method is acceptable in the U.S.A. where local codes permit, however, Canadian requirements vary depending on locality. Instal­lation must be in compliance with local codes. These appliances are equipped with a gas flex­line for use in connecting the unit to the gas line. See Figure 36 for flex-line description. The flex-line is rated for both natural and propane gas. A manual shut off valve is also provided with the flex-line.
The gas control valve is located on the right side of the unit.
When using solid gas line connector, access the valve by removing the front door assembly on the valve access side and the access plate (see Figure 37).
The electronic control valve has a 3/8" (10 mm) NPT thread gas supply inlet.
Bring the shutoff valve on the end of the flex-line over to the hard pipe and tighten with wrenches from above through the firebox opening.
Secure all joints tightly using appropriate tools and sealing compounds (ensure propane resistant compounds are used in propane ap­plications). It is recommended to seal around the gas line to prevent cold air leakage.
Figure 37
Control Panel shown with access panel removed
TEST ALL CONNECTIONS FOR GAS LEAKS (FACTORY AND FIELD):
WARNING
Never use an open flame to check for leaks.
Turn on gas supply and test for gas leaks using a gas leak test solution (also referred to as bubble leak solution).
NOTE: Using a soapy water solution is an
effective leak test solution but it is not recom­mended, because the soap residue that is left on the pipes/fittings can result in corrosion over time.
A. Light the appliance (refer to the lighting
instructions label in the control compartment or in the Care and Operation Instructions manual).
B. Brush all joints and connections with the gas
leak test solution to check for leaks. If bubbles are formed, or gas odor is detected, turn the receiver or remote control to the “OFF” position. Either tighten or refasten the leaking connection, then retest as described above.
C. When the gas lines are tested and leak-free
be sure to rinse off the leak testing solution.
D. Re-install the access plate, making certain the
gasket has not been damaged.
Step 7. CHECKING APPLIANCE OPERATION
Turn on burner then observe the individual tongues of flame on the burner. Make sure all ports are open and producing flame evenly across the burner. If any ports are blocked, or partially blocked, clean out the ports.
With gas line installed run initial system check­out before closing up the front of the unit. Follow the lighting instructions provided in the Care and Operation Instructions manual.
NOTE: Lighting Instructions are also found on the literature tag tied to the bracket above the gas valve. To access the tag, reach into the right side opening.
When first lighting the appliance, it will take a few minutes for the line to purge itself of air. Once purging is complete, the pilot and burner will light and operate as indicated in the instruction manual. Subsequent lighting of the appliance will not require such purging. Inspect the pilot flame (remove logs, if necessary, handling carefully).
Electronic Appliance Checkout
To light the burner, turn “ON” the optional remote wall switch or turn the appliance mounted ON/ OFF switch to the “ON” position. Ensure the igniter lights the pilot. The pilot flame should engulf the flame sensor as shown in Figure 38.
Figure 36—Gas Connection
NOTE: The gas supply line must be installed in accordance with building codes by a quali­fied installer approved and/or licensed as required by the locality. In the Commonwealth of Massachusetts, installation must be performed by a licensed plumber or gas fitter.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
Pilot Hood
Flame Rod (Sensor)
Figure 38
25
Page 26
Innovative Hearth Products DRT/DRC6300 Series Direct-Vent Gas Fireplaces
Installation
900343-01 11/2015
Step 8. INSTALL VOLCANIC STONE, GLOWING EMBERS, AND LOGS (Traditional Only), or GLASS MEDIA (Contemporary Only)
NOTE: If installing the Contemporary Burner/Floor Kit, skip this step and instead refer to the instructions provided with the kit.
WARNING
• DO NOT operate this appliance without the required accessories properly installed:
- floor (log set or contemporary kit), and
- firebox liner panels (ceramic or porcelain).
WARNING
• DO NOT attempt to install the logs until the appliance installation has been completed, the gas line connected and tested for leaks and the initial burner operation has been checked out.
The size and position of the log set was engineered
• to give the appliance a safe, reliable and attractive flame pattern. Any attempt to use a different log set in the fireplace will void the warranty and will result in incomplete combustion, sooting, and poor flame quality.
Logs get very hot and will remain hot up to one
• hour after gas supply is turned off. Handle only when logs are cool. Turn off all electricity to the appliance before you install grate, volcanic stone, embers and logs.
This appliance is not designed to burn wood. Any
• attempt to do so could cause irreparable damage to the appliance and prove hazardous to your safety.
If logs are not installed according to the log
• installation instructions, flame impingement and improper combustion could occur and result in soot and/or excessive production of carbon monoxide (CO), a colorless, odorless, toxic gas.
Step 1. Install the ceramic or porcelain firebox liner panels per the
instructions provided in kit.
Step 2. Place volcanic stone around the burner (the entire bag of volcanic
stone will NOT be used). DO NOT PLACE VOLCANIC STONE ON
THE BURNER. See Figure 41.
Step 3. Separate the glowing embers (rockwool) into pieces about the
size of a quarter (see Figure 39). Keep the pieces fluffed, not matted. Distribute these pieces over the burner as shown in Figure
40. Do not use more than necessary. When properly positioned, the Glowing Embers will cover approximately 75% of the burner on natural gas. For propane gas, do not place embers on main ports.
NOTE: Excessive use of embers may result in sooting or poor flame. This appliance is provided with enough Glowing Embers for several ap­plications, do not feel compelled to use all that is in a new bag. For best glowing effect, replace the ember material annually. Replacement Glowing Embers are available (Catalog Number 88L53).
26
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
Step 4. Position the individual logs as shown in Figures 42 through 46.
Logs should be placed in the order shown. Place logs 2 and 3 against the pins on the grate, NOT over them.
Proper log and twig placement is critical to encourage outstand-
ing flame appearance and prevent sooting. When positioned properly as shown, twigs will be positioned between flame peaks and will not impinge any flames.
Cat. No. Model Description
88L53 FGE Bag of Glowing Embers 80L42 FDVS Bag of Volcanic Stone H8312 PGE Bag of Platinum Embers
Table 10—Firebox Accessories / Parts
Figure 39
For Propane Gas Only: Do Not Place Embers On Main Ports.
Glowing Embers (Rockwool)
Figure 40
Volcanic Stone
Figure 41
Page 27
Traditional Only: Log Placement
3
6
Log Number Description
7
1 Log, Center 2 Log, Rear 3 Log, Center/Left 4 Log, Center/Right 5 Log, Rear/Top 6 Log, Front/Left 7 Log, Front/Center
5
Table 6 - Log Set
3
4
2
1
4
Engage Logs (3 & 4) With The Grate Pins And Align Groves At The Bottom Of The Logs Over The Grate.
Figure 44 - Placing Logs 3 and 4
6 5
Align Hole At Bottom Of Log (5) Over The Pin On Log (2).
7
2
Align Two Holes At Bottom Of Log (1) Over The Pins On The Gas Burner.
Figure 42 - Placing Log 1
1
Engage Log (6) With The Grate Pin And Align Groove At The Bottom Of The Log Over The Grate.
Engage Log (7) With The Pin On Log (4).
4
Figure 45 - Placing Logs 5, 6, and 7
Contemporary Only: Glass Media Placement
1. Spread a thin layer of the media evenly on the burner and media screen.
2
Align Groove At The Bottom Of Log (2) Over The Grate And Push It Towards The Rear.
Figure 43 - Placing Log 2
Figure 46 - Glass media installed
2. On the corner of the right media screen, arrange the media to allow
the pilot flame to reach the burner during lighting.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
27
Page 28
Innovative Hearth Products DRT/DRC6300 Series Direct-Vent Gas Fireplaces
Installation
900343-01 11/2015
Step 9. INSTALLATION AND REMOVAL OF GLASS DOOR
WARNING
When reinstalling the glass door, the door latch screws must be securely tightened to prevent the glass door from falling out, which could potentially cause damage and possible injury.
Do not attempt to substitute the materials used on this door, or replace cracked or broken glass.
Handle this glass with extreme care! Glass is susceptible to damage — Do not scratch or handle roughly while reinstall­ing the glass door frame.
The glass door of this appli- ance must only be replaced as a complete unit as provided by the manufacturer. Do not attempt to replace broken, cracked or chipped glass sepa­rately.
Do not attempt to touch the front enclosure glass with your hands while the fireplace is in use.
WARNING
Do not operate appliance with the glass front removed, cracked or broken.
AVERTISSEMENT
Ne pas utiliser l'appareil si le panneau frontal en verre n'est pas en place, est craqué ou brisé.
Installing Glass Enclosure Panel (see Figure 47)
Retrieve the glass door. Visually inspect the gasket on the backside of the frame. Gasket surface must be clean, free of irregularities and seated firmly.
Position the door in front of the firebox opening with the top of the door held away from the fireplace (Figure 47). Lower the bottom of the door assembly on the bottom door track and set on padded surface. Pivot the door up after engaging and centering in the base channel.
Using a Phillips screwdriver, fasten the door frame to the door latch with the two (2) screws. The latch should pull forward to engage the door frame.
Install the door modesty shield on top flange glass door as follows: grab the door modesty shield with both hands, with the open hem going down and engage it with the upper lip of the glass door frame by pushing it all the way down. Make sure the installed shield is firmly in place.
Barrier (see Notice, Page 28)
This fireplace comes with a barrier to reduce the likelihood of burns from touching hot glass. If the barrier is damaged, the fireplace should be turned off immediately and the fireplace must not be operated until a new, approved factory barrier for this unit is installed.
To remove barrier follow these steps.
1.Lift barrier up by the frame at the top.
2.Remove lower filler piece by pulling down off of the barrier.
3.Lower barrier and push barrier to left to release right side.
4.Pull the right side out of fireplace.
5.Remove barrier.
NOTICE:
All DRT/DRC6300 model fireplaces include a barrier to reduce the risk of burns from hot viewing glass. This barrier in the fireplace is a screen shown right.
Top Flange Glass door assembly
Screws
Firebox Floor
Glass Door Assembly
Figure 47—Installing the Glass Door
Step 10. BURNER ADJUSTMENTS
Flame Appearance and sooting
Proper flame appearance is a flame which is blue at the base and becomes yellowish-orange in the body of the flame. When the appliance is first lit, the entire flame may be blue and will gradually turn yellowish-orange during the first 15 minutes of operation. After 15 minutes of operation, if the flame is blue, or if the flame is orange with evidence of sooting (black tip), the air shutter opening may need to be adjusted.
If the air shutter opening is closed too far, sooting may develop. Sooting is indicated by black puffs developing at the tips of very long orange flames. Sooting results in black deposits forming on the logs, appliance inside surfaces and on exterior surfaces adjacent to the vent termination.
Sooting is caused by incomplete combustion in the flames and lack of combustion air enter­ing the air shutter opening. To achieve a warm yellowish-orange flame with an orange body that does not soot, the shutter opening must be adjusted between these two extremes.
Glass Door Latch (2)
28
40” Barrier Cat. No. J7422 45” Barrier Cat. No. J7423
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
Page 29
Air Shutter
Opening
Burner
Orifice
Gas
Valve
Venturi
Venturi
Air Shutter Adjustment Guidelines
• If there is smoke or soot present, first check the log set positioning to ensure that the flames are not impinging on any of the logs. If the log set is properly positioned and a sooting condition still exists, then the air shutter opening should be increased.
• The more offsets in the vent system, the larger the air shutter opening will need to be.
• An appliance operated with the air shutter opened too far, may have flames that appear blue and transparent. These weak, blue and transparent flames are termed anemic.
• Propane models may exhibit flames which candle or appear stringy. If this is present an d persists, adjust the air shutter to a more closed position, then o perate the appliance for a few more minutes to ensure that the flame nor­malizes and the flames do not appear sooty.
The following chart is provided to aid you in achieving the correct air shutter adjustment for your installation.
Use the remote to adjust the flame height as desired.
Propane models may exhibit a flame pattern that may candle or appear stringy. If this is problematic or persists as the appliance is continually operated, adjust the air shutter closed as described in the previous paragraphs. Operate the appliance for a period of time as the effect diminishes, ensuring that the appliance does not develop sooty flames. When satisfied that the appliance operates properly, proceed to finish the installation.
Main Burner Factory Air Shutter
Opening Setting—Inches (millimeter)
Model Nat.Gas Propane Gas
40 in. 45 in.
1/16 (1.59) 9/32 (7.14) 1/16 (1.59) 9/32 (7.14)
Figure 48
Amount of
Primary Air
If air shutter is closed too far
If air shutter is open too far
Flame
Color
Flame will be orange
Flame will be blue
Air Shutter
Adjustment
Air shutter gap should be increased
Air shutter gap should be decreased
Burner Air Shutter Adjustment Procedure
WARNING
Air shutter adjustment should only be performed by a quali­fied professional service technician.
Ensure that the front glass door assembly is in place and sealed After adjustment.
CAUTION
Soot will be produced if the air shutter is closed too much. Any damage due to carboning result­ing from improperly setting the air shutter is not covered under the warranty.
Contemporary Media Shown
Figure 49—Burner Flame Appearance
Oak Logs Shown
To adjust the flame, rotate the air shutter toward the back or toward the front of the fireplace. Position the air shutter to the factory setting as shown in the table in Figure 48. Allow the burner to operate for at least 15 minutes. Observe the flame continuously. If it appears weak or sooty as previously described, adjust the air shutter until the flame appearance is as desired.
Figure 50—Burner Flame Appearance
29
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
Page 30
Finish Combustible Or Non-Combustible Material
Front Face Of Fireplace
Floor Panel
Innovative Hearth Products
2 Foot Vertical
Vent & 90° Elbow
3" Min.
(76 mm)*
Top of
Appliance
10-3/8" Min.
(264 mm)
Combustible materials are
allowed above this point on the face of the appliance.
The gray shaded area must be non-combustible or Dura Rock
Header (2x4’s)
Spacers
Top of Door Frame
Fireplace (right side)
Combustible Finished Wall Materials
1
*
DRT/DRC6300 Series Direct-Vent Gas Fireplaces
Installation
900343-01 11/2015
FINISHING REQUIREMENTS Wall Details
Complete finished interior wall. To install the appliance facing flush with the finished wall, position framework to accommodate the thickness of the finished wall (Figure 51).
Non-combustible materials, such as surrounds and other appliance trim, may be installed on the appliance front face with the exceptions.
Vertical installation clearances to combustible mantels vary according to the depth of the mantel (see Figure 8). Mantels constructed of non­combustible materials may be installed at any height above the appliance opening.
Combustible materials may project beyond the side of the fireplace open­ing as long as it is kept within the shaded area illustrated in Figure 9.
j Installations with horizontal terminations which have minimum
vertical vent height only will require 4”(102mm) minimum side clearance as shown in shaded zone above. All other installations require 1" (25mm) minimum side clearance as specified in Figure 4 on Page 8.
* Insulation is NOT ALLOWED in the clearance zones around vent components. Keep this area free from combustible materials.
Figure 51
NOTE: A hearth extension is not required with this appliance.
Figure 52
NOTE: A finish trim piece is shipped with your fireplace to extend the base 1/2" to be flush with the finish flanges on the side of the fireplace. This filler is shipped on top of the fireplace wrapped in foam. If desired this piece can be placed on the base of the fireplace. It is secured with bend tabs on either side. Lay the extension in front of the base then secure by bending tabs on each side over to secure to the base. While this piece is provided it is not required.
30
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
Page 31
Step 11. INSTALLER INSTRUCTIONS—ATTACHING SAFETY-IN-OPERATION WARNINGS It is the installers responsibility to ensure these warnings are properly affixed during installation. These warning labels are a
critical step in informing consumers of safe operation of this appliance.
ATTACHING SAFETY IN OPERATION WARNINGS
It is required that the set of safety instruction labels that have been furnished with the fireplace be affixed to the operation and control points of the fireplace. A safety instruction label must be affixed to the receiver wall switch plate where the fireplace is turned on and off (See Figure A) and on the remote control handheld transmitter (See Figure B). To properly complete the installation of this fireplace, locate the multi-lingual adhesive labels provided with the Care and Operation Instructions and proceed as follows:
1. Locate the wall receiver that controls the fireplace (verify the switch operates the fireplace by turn­ing it on and off). Clean the wall receiver plate thoroughly to remove any dust and oils. Affix the label to the surface of the plate of the wall receiver that controls the fireplace (Figure A). Choose the language primarily spoken in the home. If unknown, affix the English language label.
2. Locate the remote control transmitter and clean it thoroughly to remove any dust and oils. Affix the label to the surface of handheld transmitter (Figure B). Choose the language primarily spo­ken in the home. If unknown, affix the English language label.
3. If you are unable to locate the labels, please call Innovative Hearth Products or your nearest Innovative Hearth Products dealer to receive ad­ditional safety instruction labels free of charge.
Cat. No. H8024 Replacement Label Kit
SuperiorFireplaces.com
APPOSITION DES MISES EN GARDE RELATIVES À LA SÉCURITÉ D’UTILISATION
Il est impératif que le jeu d’étiquettes de sécurité qui ont été fournies avec le foyer soient collées à côté des dispositifs de contrôle du foyer. Une étiquette de sécurité doit être collée sur la plaque du récepteur mural contrôlant l’allumage du foyer (voir Figure A) et sur le boîtier de la télécommande (Figure B). Pour achever l’installation correcte de ce foyer, procédez comme suit avec les étiquettes adhésives en langues étrangères fournies avec les instructions d’utilisation et d’entretien :
1. Repérez le récepteur mural qui contrôle le foyer (vérifiez que l’interrupteur contrôle le fonction ­nement du foyer en le faisant basculer de Marche à Arrêt, et vice-versa). Nettoyez soigneusement la plaque du récepteur mural pour éliminer la poussière et les traces de graisse ou d’huile. Collez l’étiquette sur la surface de la plaque du récepteur mural qui contrôle le foyer (Figure A). Choisissez la langue qui est principalement parlée dans la résidence du propriétaire. En cas de doute, collez l’étiquette en anglais.
2. Repérez la télécommande et nettoyez-la soigneuse­ment pour éliminer la poussière et les traces de graisse ou d’huile. Collez l’étiquette sur le boîtier de la télécommande (Figure B). Choisissez la langue qui est principalement parlée dans la résidence du propriétaire. En cas de doute, collez l’étiquette en anglais.
3. Si vous ne trouvez pas les étiquettes, veuillez appeler Innovative Hearth Products ou votre distribu­teur Innovative Hearth Products local pour recevoir gratuitement des étiquettes supplémentaires.
Étiquettes de remplacement, n° cat. H8024
SuperiorFireplaces.com
COLOCACIÓN DE ADVERTENCIAS DE SEGURIDAD EN OPERACIÓN
Se requiere que el juego de etiquetas de instrucciones de seguridad que se incluyeron con la chimenea se coloque en los puntos de operación y control de la misma. Se debe colocar una etiqueta de instrucciones de seguridad en la placa del interruptor de pared del receptor desde el cual se enciende y se apaga la chimenea (ver la Figura A) y en el transmisor de control remoto (ver la Figura B). Para completar correctamente la instalación de esta chimenea, encuentre las etiquetas adhesivas multilingües incluidas con las instrucciones de cuidado y operación y haga lo siguiente:
1. Identifique el receptor de pared que controla la chimenea (verifique que el interruptor opera la chimenea encendiéndola y apagándola). Limpie bien la placa del receptor de pared para quitar el polvo y aceite. Pegue la etiqueta en la superficie de la placa del receptor de pared que controla la chimenea (Figura A). Seleccione el idioma que más se habla en la casa. Si no sabe cuál es, use la etiqueta en inglés.
2. Identifique el transmisor de control remoto y límpielo bien para quitar el polvo y aceite. Pegue la etiqueta en la superficie del transmisor (Figura B). Seleccione el idioma que más se habla en la casa. Si no sabe cuál es, use la etiqueta en inglés.
3. Si no puede encontrar las etiquetas, sírvase llamar a Innovative Hearth Products o al distribuidor de Innovative Hearth Products más cercano para recibir etiquetas de instrucciones de seguridad adicionales gratuitas.
Juego de etiquetas de repuesto—Nº de cat. H8024
SuperiorFireplaces.com
NOTE: English is red text on clear label. French and Spanish are white text on black label.
SAFETY LABEL
DIAGRAMS
Illustrations are for example only. Your accessories may be different.
Les illustrations sont par exemple uniquement. Vos accessoires peuvent être différents.
Las ilustraciones son sólo ejemplos. Tu accesorios pueden ser diferentes.
Remarque : Le texte anglais est rouge sur un support transparent. Le texte français et espagnol est blanc sur un support noir.
DIAGRAMMES DES ÉTIQUETTES
DE SÉCURITÉ
Figure A
On
Remote
Off
PRG
Nota: La etiqueta en inglés es transparente con texto rojo. Las etiquetas en francés y español son negras con texto blanco.
DIAGRAMAS DE ETIQUETAS
DE SEGURIDAD
Figure B
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
31
Page 32
Innovative Hearth Products DRT/DRC6300 Series Direct-Vent Gas Fireplaces
INSTALLATION ACCESSORIES
Installation
900343-01 11/2015
Listed Secure Vent® Components
Cat. No.
H2266 SV8HTS Horizontal Square
H2265 SV8VTR Vertical Termination
H2250 SV8L6 6" (152mm) Vent
H2251 SV8L12 12" (305mm) Vent
H2252 SV8L24 24" (610mm) Vent
H2253 SV8L36 36" (914mm) Vent
H2254 SV8L48 48" (1219mm) Vent
H2255 SV8LA Telescopic Section H2256 SV8E45 45 Degree Elbow
Model
No.
Termination with Firestop/Spacer (H2260) and Adaptor (H2267)
Section
Section
Section
Section
Section
H2262 SV8SU Support Strap
Description
H2263 SV8SP Support Plate
H3908 SV8ARSA Attic Insulation
Shield (adjustable 12" to 22")
32
H2257 SV8E90 90 Degree Elbow
The following flashings come packaged with a storm collar
H3236 SV8F Flat Roof Flashing H2258 SV8FA 1/12 to 7/12 Adjust-
able Flashing
H2259 SV8FB 7/12 to 12/12
Adjustable Flashing
H3237 SV8SC6 Storm Collars,
6 pack
H2260 SV8HF Firestop/Spacer—
Horizontal (3-1-1 spacing)
H2261 SV8BF Firestop/Spacer—
Vertical (1-1-1 spacing)
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
Page 33
GAS CONVERSION KITS
WARNING
This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instruction is not followed exactly, a fire, explosion or production of carbon monoxide may result causing property damage, personal injury or loss of life. The qualified service agency is responsible for the proper installation of this kit. The installation is not proper and complete until the operation of the converted appliance is checked as specified in the manu­facturer’s instructions supplied with the kit. The qualified service agency performing this installation assumes responsibility for this conversion.
AVERTISSEMENT
Cette trousse de conversion doit être installée par un technicien agréé, selon les instructions du fabricant et selon toutes les exigences et tous les codes pertinents de l’autorité compétente. Assurez-vous de bien suivre les instructions dans cette notice pour réduire au minimum le risque d’incendie, d’explosion ou la production de monoxyde de carbone pouvant causer des dommages matériels, des blessures ou la mort. Le tecnicien agréé est responsable de l’installation de cette trousse. L’installation n’est pas adéquate ni complète tant que le bon fonctionnement de l’appareil converti n’a pas été vérifié selon les instructions du fabricant fournies avec la trousse. Le fournisseur de service qualifié ayant réalisé l'installation assume les responsabilités liées à la conversion.
Step 1. TURN OFF THE GAS SUPPLY TO THE APPLIANCE and disconnect power supply at the circuit breaker. Ensure appliance is cold.
CAUTION: THE GAS SUPPLY SHALL BE SHUT OFF PRIOR TO DISCONNECTING THE ELECTRICAL POWER, BEFORE PROCEEDING WITH THE CONVERSION.
ATTENTION. AVANT D’EFFECTUER LA CONVERSION, COUPEZ D’ABORD L’ALIMENTATION EN GAZ, ENSUITE, COUPEZ L’ALIMENTATION ÉLECTRIQUE.
Step 2. Remove the front glass door/frame
and the access plate from the appliance. See Figures 37 and 47.
Step 3. Carefully remove the logs and the grate assembly / contemporary media. Exercise care
so as not to break the logs / contemporary media.
Step 4. Refer to Figure 55. Remove the two
5/16" screws securing the burner to the burner brackets. Carefully slide the burner to the left to clear the venturi from the orifice. Set aside the screws and burner assembly in a secure location for later reinstallation.
Burner Assembly
In Canada: THE CONVERSION SHALL BE CAR-
RIED OUT IN ACCORDANCE WITH THE REQUIREMENTS OF THE PROVINCIAL AUTHORITIES HAVING JURISDICTION AND IN ACCORDANCE WITH THE RE­QUIREMENTS OF THE CAN/CGA-B149.1 INSTALLATION CODE.
LA CONVERSION DEVRA ÊTRE EF­FECTUÉE CONFORMÉMENT AUX RECOMMANDATIONS DES AUTORITÉS PROVINCIALES AYANT JURIDICTION ET CONFORMÉMENT AUX EXIGENCES DU CODE D'INSTALLATION CAN/CGA­B149.1.
Gas conversion kits are available to adapt your appliance from the use of one type of gas to the use of another. These kits contain all the necessary components needed to complete the task including labeling that must be affixed to ensure safe operation.
Kit part numbers are listed below, and the fol­lowing steps detail the conversion procedure.
Natural Gas to Propane Gas
Conversion Kits
Fireplace
40 in.
45 in.
Fireplace
40 in.
45 in.
Conversion Kit
Model No.
GCK-
MDLX40NP
GCK-
MDLX45NP
Propane Gas to Natural Gas
Conversion Kits
Conversion Kit
Model No.
GCK-MDLX-
40PN
GCK-MDLX-
45PN
Cat. No.
H8668
H8669
Conversion
Kit Cat. No.
H8670
H8671
Gas Valve Assembly
Burner Orifice
Figure 55
Step 5. Remove the control compartment access door and gasket by removing the twelve (12) screws securing it, and set it aside for later rein­stallation.The gas valve can be accessed through the opening, or the complete assembly can be removed by sliding the assembly to the right.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
33
Page 34
Innovative Hearth Products DRT/DRC6300 Series Direct-Vent Gas Fireplaces
Installation
900343-01 11/2015
Step 6. Refer to the instructions provided with the SIT regulator conversion kit. Using a Torx T20 (with 1/4" shank and center hole) or slotted screwdriver, remove and discard the two pressure regulator mounting screws, the pressure regulator tower, and the diaphragm assembly (if applicable). Properly dispose of all removed components. Make sure the rubber gasket installed on the back of the replacement pressure regulator is properly positioned.
Step 7. Install the new stepper motor pressure regulator assembly using the supplied screws. Securely tighten the screws (25 in-lbs).
Step 8. Attach the enclosed identification label to the valve body where it can be easily seen.
Step 9. Make stepper motor and valve electrical connections.
Step 10. Remove the pilot hood assembly to access the hexed pilot orifice. Using a 5/32". al­len wrench, remove and replace the pilot orifice with the one provided with the kit.
NOTE: Use extreme care to avoid damaging the igniter assembly.
Step 11. Refer to Figure 57 and remove the pilot hood assembly to access the hexed pilot orifice. Remove and replace the orifice with the one provided with the kit.
Step 12. (Refer to Figure 55 on Page 33 and Figure 58)
VERIFY THE PROPER ORIFICE SIZE BE­FORE INSTALLING IT.
Pilot Hood
Pilot Orifice
Figure 57
A. Remove the orifice from the manifold and
replace it with the one provided in the kit. See the following table for orifice sizes for natural and propane models. Figure 58 illustrates the orifice. Use pipe joint compound or Tef­lon tape on all pipe fittings before installing (ensure propane resistant compounds are used in propane applications, do not use pipe joint compounds on flare fittings).
B. Retrieve the burner and slide the venturi tube
over the orifice. Set the burner assembly into its position and secure it.
C. Reinstall the grate assembly. Step 13. Reassemble the remaining compo-
nents by reversing the procedures outlined in the preceding steps.
Step 14. Attach the conversion label provided in the conversion kit to the rating plate on the appliance.
Step 15. Apply gas to the system and relight appliance. With the main burner "ON", test the new pressure regulator assembly and all gas line joints for leaks using a gas leak test solu­tion. See Test All Connections For Gas Leaks on Page 25.
Burner Orifice Sizes
Elevation 0–4500 ft ( 0–1372 m)
Model
40"
Traditional
45"
40" CD
45" CD
Contemporary
Table 11
Nat.Gas
drill size (inches)
0.1405" (#28)*
• H2286
0.150" (#25)*
• J8001
0.1405" (#28)*
• H2286
0.150" (#25)*
• J8001
* Standard size installed at factory
• Part /Cat. Number
Propane
drill size (inches)
0.082" (#45)*
• J8002
0.086" (#44)*
• H2287
0.073" (#49)*
• H8807
0.073" (#49)*
• H8807
Figure 58
Step 16. Relight the main burner and verify proper burner ignition and operation. See Burner Adjustments Pages 26 and 27.
Inspect the pilot system for proper flame. The pilot flame should engulf the flame sensor as shown in Figure 59.
The lighting instructions can be found on the lighting label in the control compartment or in the Care and Operation Manual provided with the appliance.
Step 17. Using a manometer, test the inlet and manifold gas pressures. See Tables 2 and 3 on Page 6.
ALWAYS TEST PRESSURES WITH THE VALVE REGULATOR CONTROL AT THE HIGHEST SETTING.
SEE PAGE 28 FOR AIR SHUTTER ADJUSTMENT GUIDELINES.
34
(from DFC Wire Harness)
Manifold (OUT) Test Port
Inlet (IN) Test Port
Wire
(from DFC Wire
Harness)
Main Gas Inlet
3/8" NPT
Figure 56
Green Wire
Connect GTMS wire harness.
Pressure Regulator Tower
Yellow Ground Wire (from DFC Wire Harness)
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
Flame Sensor
Figure 59
Igniter Rod
Pilot Hood
Pilot Nozzles
Page 35
Innovative Hearth Products DRT/DRC6300 Series Direct-Vent Gas Fireplaces
IMPORTANT SAFETY INFORMATION
Operation
900343-01 11/2015
Important Safety Informa­tion
1. WARNING: Do not operate appliance with the glass front removed, cracked or broken.
2. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
3. Due to high temperatures, the ap­pliance should be located out of traffic and away from furniture and draperies.
4. Children and adults should be alerted to the hazards of high surface temper­ature and should stay away to avoid burns or clothing ignition.
5. Clothing or other flammable material should not be placed on or near the appliance.
6. Young children should be carefully supervised when they are in the same room as the appliance. Toddlers, young children, and others may be susceptible to accidental contact burns. A physical barrier is recom­mended if there are at-risk individuals in the house. To restrict access to a fireplace or stove, install an adjust­able safety gate to keep toddlers, young children, and other at-risk individuals out of the room and away from hot surfaces.
7. Any safety screen, guard or barrier removed for servicing an appliance must be replaced prior to operating the appliance.
8. Installation and repair should be done by a qualified service person. The appliance should be inspected before use and at least annually by a profes­sional service person. More frequent cleaning may be required due to ex­cessive lint from carpeting, bedding material, et cetera. It is imperative that control compartments, burners, and circulating air passageways of the appliance be kept clean. See maintenance instructions on Page 40.
L’information de sûreté importante
1. AVERTISSEMENT. Ne pas utiliser l’appareil si le panneau frontal en verre n’est pas en place, est craqué ou brisé.
2. Ne pas se servir de cet appareil s’il a été plongé dans l’eau, même partiellement. Faire inspecter l'appareil par un technicien qualifié et remplacer toute partie du sys­téme de contrôle et toute commande qui ont été plongées dans l'eau.
3. En raison des températures élevées, l’appareil devrait être installé dans un endroit où il y a peu de circulation et loin du mobilier et des tentures.
4. Les enfants et les adultes devraient être informés des dangers que posent les tem­pératures de surface élevées et se tenir à distance afin d’éviter des brûlures ou que leurs vêtements ne s’enflamment.
5. On ne devrait pas placer de vêtements ni d’autres matières inflammables sur l’appareil ni à proximité.
6. Les jeunes enfants devraient être surveillés étroitement lorsqu’ils se trouvent dans la même pièce que l’appareil. Les tout petits, les jeunes enfants ou les adultes peuvent subir des brûlures s’ils viennent en contact avec la surface chaude. Il est recommandé d’installer une barrière physique si des personnes à risques habitent la maison. Pour empêcher l’accès à un foyer ou à un poêle, installez une barrière de sécurité ; cette mesure empêchera les tout petits, les jeunes enfants et toute autre personne à risque d’avoir accès à la pièce et aux surfaces chaudes.
7. Tout écran ou protecteur retiré pour per­mettre l’entretien de l’appareil doit être remis en place avant de mettre l’appareil en marche.
8. L’installation et la réparation devrait être confiées à un technicien qualifié. L’appareil devrait faire l’objet d’une inspection par un technicien professionnel avant d’être utilisé et au moins une fois l’an par la suite. Des nettoyages plus fréquents peuvent être nécessaires si les tapis, la literie, et cetera produisent une quantité importante de poussière. Il est essentiel que les com­partiments abritant les commandes, les brûleurs et les conduits de circulation d’air de l’appareil soient tenus propres. Voyez les instructions d’entretien à la page 40.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
Información importante de seguridad
1. ADVERTENCIA: No opere el artefacto con el frente de vidrio quitado, agrietado o roto.
2. No use este artefacto si alguna de sus partes ha estado bajo agua. Llame de inmediato a un técnico de servicio calificado para que inspeccione el artefacto y reemplace cualquier parte del sistema de control y cualquier control de gas que haya estado bajo agua.
3. Debido a las altas temperaturas, el artefacto debe situarse fuera de las áreas de tráfico y lejos del mobiliario y cortinas.
4. Se debe alertar a los niños y adultos sobre los peligros de las altas temperaturas en la superficie y que se mantengan alejados para evitar quemaduras o ignición de la ropa.
5. No debe colocarse ropa u otros materiales inflamables sobre y cerca del artefacto.
6. Se debe supervisar de cerca a los niños cuando estén en el mismo cuarto que el artefacto. Los niños pequeños, los jóvenes y otras personas pueden ser susceptibles a quemaduras por contacto accidental. Se recomienda instalar una barrera física si hay personas en riesgo en la casa. Para restringir el acceso a una chimenea o estufa, instale una puerta de seguridad ajustable para mantener a los niños pequeños, jóvenes y otras personas en riesgo fuera del cuarto y lejos de las superficies calientes.
7. Cualquier malla o resguardo de seguridad quitado para dar servicio a un artefacto, debe reinstalarse antes de operar el artefacto.
8. Una persona de servicio competente debe realizar la instalación y reparación. Una persona de servicio profesional debe inspeccionar el artefacto antes de usar al menos una vez por año. Se puede requerir limpieza más frecuente debido a la pelusa excesiva del alfombrado, del material de cobijas, etc. Es imprescindible mantener limpios los compartimientos de control, los quemadores y los pasajes de circulación del aire del artefacto. Ver las instrucciones de mantenimiento en la página 40.
35
Page 36
Innovative Hearth Products DRT/DRC6300 Series Direct-Vent Gas Fireplaces
HOMEOWNER’S INSTRUCTIONS - ATTACHING SAFETY IN OPERATION WARNINGS
Operation
900343-01 11/2015
ATTACHING SAFETY IN OPERATION WARN­INGS
Your fireplace has been furnished with safety instruc­tion labels that are to be affixed to the operation and control points of the fireplace. A safety instruction label should be affixed to the receiver wall switch plate where the fireplace is turned on and off (See Figure A) and the remote control handheld transmitter (Figure B). The warnings should already have been put in place when the fireplace initial set-up was completed. If they are not affixed at these spots, locate the multi-lingual adhesive labels provided with these instructions and proceed as follows:
1. Locate the wall receiver that controls the fireplace (verify the switch operates the fireplace by turn­ing it on and off). Clean the wall receiver plate thoroughly to remove any dust and oils. Affix the label to the surface of the plate of the wall receiver that controls the fireplace (Figure A). Choose the language primarily spoken in the home.
2. Locate the remote control transmitter and clean it thoroughly to remove any dust and oils. Affix the label to the surface of handheld transmitter (Figure B). Choose the language primarily spoken in the home.
3. If you are unable to locate the labels, please call Innovative Hearth Products or your nearest Innovative Hearth Products dealer to receive ad­ditional safety instruction labels free of charge.
Cat. No. H8024 Replacement Label Kit
INNOVATIVE HEARTH PRODUCTS SuperiorFireplaces.com
Note: English is red text on clear label. French and Spanish are white text on black label.
APPOSITION DES MISES EN GARDE RELATIVES À LA SÉCURITÉ D’UTILISATION
Votre foyer a été livré avec des étiquettes de sécurité qui doivent être collées à côté des dispositifs de contrôle du foyer. Une étiquette de sécurité devrait être collée sur la plaque du récepteur mural contrôlant l’allumage du foyer (voir Figure A) et sur le boîtier de la télécommande (Figure B). Les mises en garde auraient dû être collées au moment de l’installation initiale du foyer. Si ce n’est pas le cas, prenez les étiquettes adhésives multilingues fournies avec ces instructions et procédez comme suit:
1. Repérez le récepteur mural qui contrôle le foyer (vérifiez que l’interrupteur contrôle le fonction­nement du foyer en le faisant basculer de Marche à Arrêt, et vice-versa). Nettoyez soigneusement la plaque du récepteur mural pour éliminer la poussière et les traces de graisse ou d’huile. Collez l’étiquette sur la surface de la plaque du récepteur mural qui contrôle le foyer (Figure A). Choisissez la langue qui est principalement parlée dans la résidence du propriétaire.
2. Repérez la télécommande et nettoyez-la soigneuse­ment pour éliminer la poussière et les traces de graisse ou d’huile. Collez l’étiquette sur le boîtier de la télécommande (Figure B). Choisissez la langue qui est principalement parlée dans la résidence du propriétaire.
3. Si vous ne trouvez pas les étiquettes, veuillez appeler Innovative Hearth Products ou votre distribu teur Innovative Hearth Products local pour recevoir gratuitement des étiquettes supplémentaires.
Étiquettes de remplacement, n° cat. H8024
INNOVATIVE HEARTH PRODUCTS SuperiorFireplaces.com
Remarque : Le texte anglais est rouge sur un support transparent. Le texte français et espagnol est blanc sur un support noir.
COLOCACIÓN DE ADVERTENCIAS DE SEGURIDAD EN OPERACIÓN
Su chimenea incluye etiquetas de instrucciones de seguridad que deben colocarse en los puntos de operación y control de la chimenea. Se debe colocar una etiqueta de instrucciones de seguridad en la placa del interruptor de pared del receptor desde el cual se enciende y se apaga la chimenea (ver la
Figura A) y en el transmisor de control remoto (Figura B). Las advertencias ya deben haberse colocado cuando
se completó la instalación inicial de la chimenea. Si no están colocadas en estos lugares, encuentre las etiquetas adhesivas multilingües proporcionadas con estas instrucciones y prosiga de la siguiente manera:
1. Identifique el receptor de pared que controla la chimenea (verifique que el interruptor opera la chimenea encendiéndola y apagándola). Limpie bien la placa del receptor de pared para quitar el polvo y aceite. Pegue la etiqueta en la superficie de la placa del receptor de pared que controla la chimenea (Figura A). Seleccione el idioma que más se habla en la casa.
2. Identifique el transmisor de control remoto y límpielo bien para quitar el polvo y aceite. Pegue la etiqueta en la superficie del transmisor (Figura B). Seleccione el idioma que más se habla en la casa.
3. Si no puede encontrar las etiquetas, sírvase llamar a Innovative Hearth Products o al distribuidor de Innovative Hearth Products más cercano para recibir etiquetas de instrucciones de seguridad adicionales gratuitas.
Juego de etiquetas de repuesto - Nº de cat. H8024
INNOVATIVE HEARTH PRODUCTS SuperiorFireplaces.com
Nota: La etiqueta en inglés es transparente con texto rojo. Las etiquetas en francés y español son negras con texto blanco.
36
SAFETY LABEL DIAGRAMS DIAGRAMAS DE ETIQUETAS DE
Illustrations are for example only. Your accessories may be different.
Les illustrations sont par exemple uniquement. Vos accessoires peuvent être différents.
Las ilustraciones son sólo ejemplos. Tu accesorios pueden ser diferentes.
DIAGRAMMES DES ÉTIQUETTES
DE SÉCURITÉ
Figure A
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
On
Remote
Off
PRG
SEGURIDAD
Figure B
Page 37
Innovative Hearth Products DRT/DRC6300 Series Direct-Vent Gas Fireplaces
Operation
900343-01 11/2015
APPLIANCE INSTALLATION, SERVICE, AND MAINTENANCE NOTICES
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to the owner’s information manual provided with this appliance. For assistance or additional information consult a qualified installer, service agency or the gas supplier.
AVERTISSEMENT : Une installation, un réglage, une modification, une réparation ou un entretien mal effectué peut causer des dommages matériels ou des blessures. Voir la notice de l’utilisateur qui accompgne l’appareil. Pour de l’aide ou des renseignements supplémentaires, consultez un installateur, un technicien agréé ou le fournisseur de gaz.
Only trim kit(s) supplied by the manufac­turer shall be used in the installation of this appliance.
Seules les trousses de garniture fournies par le fabricant doivent être utilisées pour l’installation de cet appareil.
These appliances must not be connected to a chimney or flue serving a separate solid fuel burning appliance.
Any change to this appliance and/or its operating controls is dangerous. Improper installation or use of this appliance can cause serious injury or death from fire, burns, explosion or carbon monoxide poisoning.
CARBON MONOXIDE POISONING: Early signs of carbon monoxide poisoning are similar to the flu with headaches, dizzi­ness and/or nausea. If you have these signs, obtain fresh air immediately. Turn off the gas supply to the appliance and have it serviced by a qualified professional, as it may not be operating correctly. Some people are more affected by carbon monoxide than others, including pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.
Turn off gas and electrical power to the fireplace and allow it to cool before cleaning or servicing the appliance.
If the barrier becomes damaged, the barrier shall be replaced with the manufacturer’s barrier for this appliance.
Si l’écran est endommagé, il doit être remplacé par celui fournit par le fabricant de cet appareil.
For use with barrier(s) part no(s). J7422 (40” models) and J7423 (45” models).
Reinstall any barrier removed before operating the appliance. The barrier is designed to reduce the risk of burns from hot glass. Do not operate the appliance without the barrier installed.
The vent termination is hot while in operation and for a period of time fol­lowing the use of the fireplace. Young children should be carefully supervised when they are in the same area as a hot termination.
APPLIANCE OPERATION NOTICES
Do not operate appliance with the glass front removed, cracked, or broken.
These fireplaces are vented gas appli­ances. Do not burn wood or other material in these appliances.
This appliance is only for use with the type of gas indicated on rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
Cet appareil doit être utilisé uniquement avec les types de gaz indiqués sur la plaque signalétique. Ne pas l’utiliser avec d’autres gaz sauf si un kit de conversion certifié est installé.
These appliances are designed to operate on natural gas or propane gas only. The use of other fuels or combinations of fuels will degrade the performance of this system and may be dangerous.
Provide adequate clearances around air openings and adequate accessibility clearance for service and proper opera­tion. Never obstruct the front openings of the appliance.
Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control that has been under water.
CAUTION: Hot while in operation. Do not touch. Severe Burns may result. Keep children, clothing furniture, gasoline and other liquids having flammable vapors away.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
ATTENTION : L’appareil est chaud lorsqu’il fonctionne. Ne pas toucher l’appareil. Risque de brûlures graves. Surveiller les enfants. Garder les vêtements, les meubles, l’essence ou autres liquides produisant des vapeur inflammables loin de l’appareil.
WARRANTY INFORMATION
Your gas appliance is covered by a limited 20-year warranty. You will find a copy of the warranty accompanying this manual. Please read the warranty to be familiar with its coverage.
Retain this manual. File it with your other docu­ments for future reference.
Failure to comply with the installation and operating instructions provided will result in an improperly installed and operating appliance, voiding its warranty.
Do not attempt to alter or modify the construction of the appliance or its com­ponents. Any modification or alteration may void the warranty, certification, and listings of this unit.
GENERAL INFORMATION
The fireplace models covered in this manual are direct-vent, sealed combustion gas fireplaces designed for residential application. Direct­vent appliances operate with the combustion chamber completely isolated from the indoor environment.
All air for combustion is brought in from the outside and exhaust gases are vented through the same direct-vent, co-axial (intake/exhaust) vent system.
The appliances are designed to operate on natural or propane gas only and contain an electronic intermittent pilot system. Electrical power (120 Vac line voltage) is recommended to operate the fireplace; however, four (4) "AA" batteries can be used for full-time operation or as a backup in case of a power outage.
These appliances comply with National Safety Standards and are tested and listed by PFS (Report No. F14-106) to ANSI Z21.50 (in Canada, CSA-2.22), and CAN/CGA-2.17-M91 in both the USA and Canada as vented gas fireplaces.
The Installation must conform to local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54—lat­est edition, or the Natural Gas and Propane Installation Code, CAN/CGA-B149.1—latest edition. The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70—latest edition, or the Canadian Electrical Code, CSA C22.1—latest edition.
37
Page 38
Innovative Hearth Products DRT/DRC6300 Series Direct-Vent Gas Fireplaces
Operation
900343-01 11/2015
BTU INPUT
The BTU Input for these appliances are shown in Table 12.
Model No. Input (BTU/Hr)
Natural Gas
40 in. 32,000–50,000 45 in. 40,000-57,000
Propane Gas
40 in. 32,000–50,000 45 in. 43,000–56,000
Table 1: Input (BTU/HR)
Table 12 - Input (BTU/HR
GAS PRESSURE
Table 2 and Table 13 show the appliances' gas pressure requirements.
Fuel # Minimum Maximum
Natural Gas
Propane
5.5" WC
(1.37 kPa)
11.0" WC
(2.74 kPa)
10.5" WC
(2.61 kPa)
13.0" WC
(3.23 kPa)
Table 13 - Inlet Gas Supply Pressure
Fuel # Low High
Natural Gas
Propane
1.6" WC (.4 kPa)
6.3" WC
(1.57 kPa)
3.5" WC
(.87 kPa)
10.0" WC
(2.49 kPa)
Table 14 - Manifold Gas Supply Pressure
Test gauge connections are provided on the front of the gas control valve, identified IN for the inlet and OUT for the manifold side (see Figure 60 on Page 39). The control valves have a 3/8" (10 mm) NPT thread inlet and outlet side of the valve.
Propane tanks are at pressures that will cause damage to valve components. Verify that the tanks have step down regulators to reduce the pressure to safe levels.
The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psi (3.5 kPa).
The appliance must be isolated from the gas supply piping system by closing its equipment shutoff valve during any pressure testing of the gas supply piping system at test pres­sures equal to or less than 1/2 psi (3.5 kPa).
Orifice Sizes— Sea Level to High Altitude (All Models)
These appliances are tested and approved for installation at elevations of 0-4500 feet (0-1372 meters) above sea level using the standard burner orifice sizes (marked with an "*" in Table 14 ).
For elevations above 4500 feet, contact your gas supplier or qualified service technician.
Deration—At higher elevations, the amount of BTU fuel value delivered must be reduced by either using gas that has been derated by the gas company or by changing the burner orifice to a smaller size as regulated by the local authorities having jurisdiction and by the (USA) National Fuel Gas Code NFPA 54/ANSI Z223.1—latest edition or, in Canada, the CAN/ CGA-B149.1 codes—latest edition.
Install the appliance according to the regulations of the local authorities having jurisdiction and, in the USA, the National Fuel Gas Code NFPA 54 / ANSI Z223.1—latest edition or, in Canada, the CAN/CGA-B149.1—latest edition.
Flame breadth, height and width will diminish 4% for every 1,000 feet of altitude.
Burner Orifice Sizes
Elevation 0–4500 ft ( 0–1372 m)
Model
40"
Traditional
45"
40" CD
45" CD
Contemporary
Table 15
Nat.Gas
drill size (inches)
0.1405" (#28)*
• H2286
0.150" (#25)*
• J8001
0.1405" (#28)*
• H2286
0.150" (#25)*
• J8001
* Standard size installed at factory
• Part /Cat. Number
Propane
drill size (inches)
0.082" (#45)*
• J8002
0.086" (#44)*
• H2287
0.073" (#49)*
• H8807
0.073" (#49)*
• H8807
In Canada—CAN/CGA-2.17-M91 (R2009) (high altitude):
THE CONVERSION SHALL BE CARRIED OUT BY A MANUFACTURER’S AUTHO­RIZED REPRESENTATIVE, IN ACCOR­DANCE WITH THE REQUIREMENTS OF THE MANUFACTURER, PROVINCIAL OR TERRITORIAL AUTHORITIES HAVING JURISDICTION AND IN ACCORDANCE WITH THE REQUIREMENTS OF THE CAN/CGA-B149.1 OR CAN/CGA-B149.2 INSTALLATION CODES.
Burn-in Period
During the first few fires of this appliance there will be some odor due to the curing of the paint and burning off of lubricants used in the manufacturing process. Depending on your use, the burn-in period may take a few hours or a few days.
KEEP YOUR HOUSE WELL VENTILATED DURING THE CURING PROCESS. THE ODOR AND HAZE EMITTED DURING THE CURING PROCESS CAN BE QUITE NOTICEABLE AND MAY SET OFF A SMOKE DETECTOR.
NOTICE: A white film may develop
on the glass enclosure panel during the first few fires as part of the burn-in process.
The first few times you use the fireplace, clean the glass after each use (AFTER THE GLASS HAS COMPLETELY COOLED); otherwise, the white film will bake onto the glass and become difficult to remove.
See glass cleaning instructions on Page 41.
38
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
Page 39
Innovative Hearth Products
Gas Valve
Access Plate
Right Side
Modesty Panel
DRT/DRC6300 Series Direct-Vent Gas Fireplaces
OPERATION AND CARE OF YOUR APPLIANCE
WARNING
Young children should be carefully supervised when they are in the same room as the appliance. Toddlers, young children and others may be susceptible to accidental contact burns. A physical barrier is recommended if there are at risk individuals in the house. To restrict access to a fireplace or stove, install an adjustable safety gate to keep toddlers, young children and other at risk individuals out of the room and away from hot surfaces.
AVERTISSEMENT
Les jeunes enfants devraient être surveillés étroitement lorsqu’ils se trouvent dans la même pièce que l’appareil. Les tout petits, les jeunes enfants ou les adultes peuvent subir des brûlures s’ils viennent en contact avec la surface chaude. Il est recommandé d’installer une barrière physique si des personnes à risques habitent la maison. Pour empêcher l’accès à un foyer ou à un poêle, installez une barrière de sécurité; cette mesure empêchera les tout petits, les jeunes enfants et toute autre personne à risque d’avoir accès à la pièce et aux surfaces chaudes.
Gas Controls / Control Compartment Access
The gas controls can be found on the right hand side of the appliance as shown in Figure 61.
The standard controls for appliance operation are remote wall switch and remote control.
Operation and Care of Your Appliance
Familiarize yourself with the gas control valve that your appliance uses. Refer to Figure 2 for access to the gas control valve.
Appliances are fitted with the electronic valve shown in Figure 60.
To light the appliance refer to the detailed lighting instructions (see Page 49). The appliance lighting instructions can also be found on the pull-out labels attached to the gas control valve.
Your appliance is equipped with a wall receiver switch and a remote control.
lighting instruction
Operation
900343-01 11/2015
Figure 61—Fireplace Interior, Right Side, panel removed
Variable Flame Height Adjustment
All appliances are equipped with a variable gas control valve. Flame height for these models may be adjusted through a range between fixed low and high settings, alternately, while the appliance is in operation. Use the remote control to adjust the flame height as desired.
Green Wire
(From DFC Wire
Harness)
Manifold (Out)
Test Port
Inlet (In) Test Port
Wire
(From DFC Wire
Harness)
Main Gas
Inlet
3/8" NPT
Figure 60—SIT Proflame Valve
Connect GTMS Wire Harness
Pressure Regulator Tower
Yellow Ground Wire (From DFC Wire Harness)
39
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
Page 40
Innovative Hearth Products DRT/DRC6300 Series Direct-Vent Gas Fireplaces
Operation
900343-01 11/2015
MAINTENANCE
(See Maintenance Schedule, Page 51)
Refer to the maintenance schedule for maintenance tasks, procedures, frequency and by whom they should be performed. Always verify proper opera­tion of the appliance after servicing.
WARNING
Turn off gas and electrical power to the fireplace and allow it to cool before cleaning or servicing the appliance.
CAUTION: Wear gloves and safety glasses for protection while doing required main­tenance.
Verify proper operation after servicing. S'assurer que l'appareil fonctionne adé-
quatement une fois l'entretien terminé. Always turn off the gas before cleaning.
Before re-lighting, refer to the lighting instructions in this manual. Instructions are also found on a pull-out panel located in the control compartment.
Always keep the appliance area clear and free from combustible materials, gasoline and other flammable liquids.
Inspect Venting System
The appliance and venting system should be thoroughly inspected before initial use and at least annually by a qualified service techni­cian (inspection should include ensuring that exhaust or intake passages are unobstructed and vent components are properly assembled and not damaged). Homeowner must contact
a qualified service technician at once if any abnormal condition is observed.
If the venting system is disassembled for any reason, a qualified service technician should follow vent installation instructions for proper reassembly and proper sealing of the venting system components. However, more frequent periodic inspections and cleanings should be performed by the homeowner.
Glass Cleaning
(see Front Glass Enclosure Panel, Removal and Installation on Page 41).
NOTE: Clean glass after first two weeks of operation (after Burn-In period is over) and then only when necessary and when the fireplace is cool. Wipe surface with a clean, dampened, soft cloth. Follow with a dry, soft towel as desired. Take care not to scratch the glass surface.
WARNING: Do not use abrasive cleaners on glass. Never clean the glass when it is hot.
40
The viewing glass should be cleaned periodi­cally to remove any build-up caused from the following:
• During start-up, it is normal for condensa­tion to form on the inside of the glass (this condensation and fog will usually disappear in a few minutes). The moisture can cause lint, dust and other airborne particles to cling to the glass surface.
• Initial curing of the high temperature paint and burning off of lubricants used in the manufacturing process may result in a film on the glass.
• A white coating may form on the glass as a result of impurities and minerals in the fuel.
It is recommended that the glass be cleaned two or three times during each heating season, depending on the circumstances present. The following cleaning solutions are approved for use to clean glass:
• Non-ammonia based household cleaner
• Gas fireplace/stove glass cleaner
Inspect Glass Gasket—Visually inspect the
gasket on the backside of the glass enclosure panels. The gasket surface must be clean, free of irregularities and seated firmly.
Clean Control Compartment
Keep control compartment clean by vacuuming or brushing at least twice a year. More frequent cleaning may be required due to excessive lint from carpeting, bedding materials, etc. It is important that control compartments, burners and circulating air passageways of the appliance be kept clean.
Clean Logs and Burner
Carefully remove the logs (use care when han­dling the fiber logs, as they become quite fragile after curing). Vacuum out any foreign matter (lint, carbon, etc.) on the burner. Ensure the burner ports are “open.” Remove any carbon deposits from the under side of the logs using a vacuum cleaner, or a soft bristled brush (i.e. paint brush).
NOTE: Improper positioning of logs can create carbon build-up and will alter the performance of the appliance.
Replacing Logs
If the logs become damaged by accident or improper handling and need replacement, use only the proper replacement logs from manu­facturer (see Page 46 for ordering information).
Reinstall Embers, Volcanic Stone and Logs
Carefully follow placement instructions on Pages 42 and 43. All logs should fit onto cor­responding pins and/or log stoppers. This will ensure a proper flame and safe combustion.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
NOTE: If installing the Contemporary Burner/ Floor Kit, skip this step and instead refer to the instructions provided with the kit.
Inspect Wiring
Refer to wiring diagrams on Page 46.
CAUTION: Label all wires prior to discon­nection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.
ATTENTION: Au moment de l'entretien des commandes, étiquetez tous les fils avant de les débrancher. Des erreurs de cáblage peuvent entraîner un fonc­tionnement inadéquat et dangereux.
Inspect and clean all wire connections. Ensure that there is no melting or damage. Inspection should include:
• Terminals at the Valve
• Wall OFF/ON Switch
Low Battery Power Detection
The life span of the remote control system batteries depends on these factors:
• the quality of the batteries used
• the number of appliance ignitions
When the batteries are low, the receiver will emit two (2) “beeps” (low battery alert) every time it receives a command from the transmitter.
After the batteries are replaced it will emit one (1) “beep” when a command is sent by pressing any key on the transmitter. See "Initialization of The System" located in the Installation Instructions.
Inspect Burner Flame and Pilot Flame Appearance
Periodically do a visual check of the burner flame and the pilot flame. Ensure that the burner flame appearance resembles the flame shown in Figures 71 and 72 and as described in Flame Appearance and Sooting on Page
44. Refer to Figure 73 on Page 45 for more information about the pilot flame appearance. Contact a qualified service technician at once if any abnormal condition is observed.
Small Area Paint Touch-up
Only use a factory supplied paint kit for touch­ups. Paint is available at your local Innovative Hearth Products dealer. Never attempt to paint a hot fireplace.
Do not attempt to repaint the appliance until the finish is completely cured (see Burn-In Period on Page 38). If the surface later becomes stained or marred, it can be lightly sanded and touched up with spray paint (see Page 40).
Page 41
Innovative Hearth Products DRT/DRC6300 Series Direct-Vent Gas Fireplaces
Operation
900343-01 11/2015
FRONT GLASS ENCLOSURE PANEL, REMOVAL AND INSTALLATION
WARNING
• When reinstalling the glass door, the door latch screws must be securely tightened to prevent the glass door from falling out, which could potentially cause damage and possible injury.
• Do not attempt to substitute the materials used on this door, or replace cracked or broken glass.
• Handle this glass with ex­treme care! Glass is sus­ceptible to damage – Do not scratch or handle roughly while reinstalling the glass door frame.
• The glass door of this appli­ance must only be replaced as a complete unit as provided by the manufacturer. Do not attempt to replace broken, cracked or chipped glass separately.
• Do not attempt to touch the front enclosure glass with your hands while the fireplace is in use.
WARNING
Do not operate appliance with the glass front removed, cracked or broken.
AVERTISSEMENT
Ne pas utiliser l'appareil si le panneau frontal en verre n'est pas en place, est craqué ou brisé.
WARNING
Any safety screen or guard removed for servicing the ap­pliance must be replaced prior to operating the appliance.
AVERTISSEMENT
Tout écran ou protecteur re­tiré pour permettre l’entretien de l’appareil doit être remis en place avant de mettre l’appareil en marche.
Only doors certified with the appliance shall be used.
Seules des portes certifiées pour cet appareil doivent être utilisées.
WARNING: DO NOT abuse glass door by striking or slamming shut.
These are direct-vent appliances. They are designed to operate only when the front glass enclosure panel is installed. Generally the front glass enclosure panel should not be removed except to gain access to the components within the firebox.
Barrier (see Notice, Page 28)
This fireplace comes with a barrier to reduce the likelihood of burns from touching hot glass. If the barrier is damaged, the fireplace should be turned off immediately and the fireplace must not be operated until a new, approved factory barrier for this unit is installed.
To remove barrier follow these steps.
1.Lift barrier up by the frame at the top.
2.Remove lower filler piece by pulling down off of the barrier.
3.Lower barrier and push barrier to left to release right side.
4.Pull the right side out of fireplace.
5.Remove barrier.
6. Install the new, approved factory barrier with flat side of barrier toward firebox.
To install the front glass door assembly, proceed as follows:
3. Swing the door up and back. Ensure the gasket seats evenly as the door draws shut. Engage the nut insert and fasten with two screws to secure the door.
4. Install the door modesty shield on top flange glass door as follows: grab the door modesty shield with both hands, with the open hem going down and engage it with the upper lip of the glass door frame by pushing it all the way down. Make sure the installed shield is firmly in place.
5. With the firescreen hanging on the screen rod, drop in the right side of the rod to the right modesty panel. Then drop in the left side of the rod through the slot of the left modesty panel. Make sure that the rod is supported by the bracket in the center of the fireplace.
Top Flange Glass Door Frame Assembly
Screws
Firebox Floor
Glass Door Assembly
Figure 62—Glass Door Assembly Removal/Installation
Glass Door Latch (2)
1. Retrieve the glass door assembly. Visually inspect the gasket on the backside of the panel. The gasket surface must be clean, free of irregularities and seated firmly.
2. Position the door frame in front of the firebox opening and engage the bottom flange over the rail at the bottom of the firebox opening.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
41
Page 42
Innovative Hearth Products DRT/DRC6300 Series Direct-Vent Gas Fireplaces
Operation
900343-01 11/2015
INSTALL VOLCANIC STONE, GLOWING EMBERS, AND LOGS (TRADITIONAL ONLY), OR GLASS MEDIA (CONTEMPORARY ONLY)
NOTE: If installing the Contemporary Burner/Floor Kit, skip this step and instead refer to the instructions pro­vided with the kit.
WARNING
• DO NOT attempt to install the logs until the appliance installation has been completed, the gas line connected and tested for leaks and the initial burner operation has been checked out.
• The size and position of the log set was engi­neered to give the appliance a safe, reliable and attractive flame pattern. Any attempt to use a different log set in the fireplace will void the warranty and will result in incomplete combus­tion, sooting, and poor flame quality.
• Logs get very hot and will remain hot up to one hour after gas supply is turned off. Handle only when logs are cool. Turn off all electricity to the appliance before you install grate, volcanic stone, embers, and logs.
• This appliance is not designed to burn wood. Any attempt to do so could cause irreparable damage to the appliance and prove hazardous to your safety.
• If logs are not installed according to the log installation instructions, flame impingement and improper combustion could occur and result in soot and/or excessive production of carbon monoxide (CO), a colorless, odorless, toxic gas.
4. Position the individual logs as shown in Figure 7 through Figure 11 on Page 11. Logs should be placed in the order shown. Place logs 2 and 3 against the pins on the grate, NOT over them.
Proper log and twig placement is critical to encourage outstanding
flame appearance and prevent sooting. When positioned properly as shown, twigs will be positioned between flame peaks and will not impinge any flames. Positioning is the same for all colors of log sets.
Cat. No. Model Description
88L53 FGE Bag of Glowing Embers 80L42 FDVS Bag of Volcanic Stone
H8312 PGE Bag of Platinum Embers
Table 16:Firebox Accessories / Parts
Volcanic Stone
Figure 63—Volcanic Stone Placement
1. Install the ceramic or porcelain panels, per the instructions provided in kit (refer to document 506020-46).
2 Place volcanic stone around the burner, as shown in Figure 63.
3. Separate the glowing embers from the larger bag into pieces about the size of a quarter, as shown in Figure 64. Mix the glowing embers with the bag of platinum embers also provided with the fireplace. Keep the pieces fluffed, not matted. Distribute these pieces over the burner as shown in Figure 65. Do not use more glowing embers than necessary. When properly positioned, the glowing embers will cover approximately 75% of the burner for natural gas applications. For propane gas, do not place any glowing embers on the main ports.
NOTE: Excessive use of glowing embers may result in sooting or poor
flame. This appliance is provided with enough glowing embers for several applications. Do not use all provided, in one application. For best glowing effect, replace the ember material annually. Replacement glowing embers (P/N 88L53) and platinum embers (P/N H8312) are available.
42
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
Figure 64—Glowing Ember Separation
Main Ports.
Glowing Embers
Figure 65—Glowing Ember Placement
Page 43
Innovative Hearth Products DRT/DRC6300 Series Direct-Vent Gas Fireplaces
Traditional Only: Log Placement
Operation
900343-01 11/2015
3
6
Log Number Description
7
1 Log, Center 2 Log, Rear 3 Log, Center/Left 4 Log, Center/Right 5 Log, Rear/Top 6 Log, Front/Left 7 Log, Front/Center
5
Table 17 - Log Set
3
4
2
1
4
Engage Logs (3 & 4) With The Grate Pins And Align Groves At The Bottom Of The Logs Over The Grate.
Figure 68 - Placing Logs 3 and 4
6 5
Align Hole At Bottom Of Log (5) Over The Pin On Log (2).
7
2
Align Two Holes At Bottom Of Log (1) Over The Pins On The Gas Burner.
Figure 66 - Placing Log 1
1
Engage Log (6) With The Grate Pin And Align Groove At The Bottom Of The Log Over The Grate.
Engage Log (7) With The Pin On Log (4).
4
Figure 69 - Placing Logs 5, 6, and 7
Contemporary Only: Glass Media Placement
1. Spread a thin layer of the media evenly on the burner and media screen.
2
Align Groove At The Bottom Of Log (2) Over The Grate And Push It Towards The Rear.
Figure 67 - Placing Log 2
Figure 70 - Glass media installed
2. On the corner of the right media screen, arrange the media to allow
the pilot flame to reach the burner during lighting.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
43
Page 44
Innovative Hearth Products DRT/DRC6300 Series Direct-Vent Gas Fireplaces
Operation
900343-01 11/2015
BURNER ADJUSTMENTS
(QUALIFIED TECHNICIANS ONLY)
Flame Appearance and Sooting
Proper flame appearance is a flame which is blue at the base and becomes yellowish-orange
in the body of the flame.
When the appliance is first lit, the entire flame may be blue and will gradually turn yellowish­orange during the first 15 minutes of operation. If the flame remains blue, or if the flame is orange with evidence of sooting (black tip), the air shutter opening may need to be adjusted.
If the air shutter opening is closed too far, sooting may develop. Sooting is indicated by black puffs developing at the tips of very long orange flames. Sooting results in black deposits forming on the logs, appliance inside surfaces and on exterior surfaces adjacent to the vent termination.
Sooting is caused by incomplete combustion in the flames and lack of combustion air enter­ing the air shutter opening. To achieve a warm yellowish-orange flame with an orange body that does not soot, the shutter opening must be adjusted between these two extremes.
Contemporary Media Shown
Figure 71—Burner Flame Appearance
Rustic Oak Logs Shown
44
Figure 72—Burner Flame Appearance
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
Page 45
Innovative Hearth Products
Air Shutter
Opening
Burner
Orifice
Gas
Valve
Venturi
Venturi
DRT/DRC6300 Series Direct-Vent Gas Fireplaces
Operation
900343-01 11/2015
BURNER FLAME ADJUSTMENTS (QUALIFIED TECHNICIANS ONLY)
WARNING
• Air shutter adjustment should only be performed by a qualified professional service technician.
• Ensure that the front glass door assembly is in place and sealed After adjustment.
CAUTION
Soot will be produced if the air shutter is closed too much. Any damage due to carboning resulting from improperly setting the air shutter is not covered under the warranty.
To adjust the flame, rotate the air shutter toward the back or toward the front of the fireplace. Position the air shutter to the factory setting as shown in Figure 73. Allow the burner to operate for at least 15 minutes. Observe the flame. If it appears weak or sooty as previously described, adjust the air shutter until the flame appearance is as desired.
Main Burner Factory Air Shutter
Opening Setting—Inches (millimeter) Model Nat.Gas Propane Gas
40 in. 1/16 (1.59) 9/32 (7.14) 45 in. 1/16 (1.59) 9/32 (7.14)
Figure 73—Air Shutter Adjustment
Electronic Appliance Checkout
To light the burner, turn on the remote control. Ensure the igniter lights the pilot. The pilot flame should engulf the flame rod as shown in Figure 74.
Pilot Hood
Flame Sensor
Pilot Nozzels
Igniter Rod
Figure 74—Pilot Assembly— Proper Pilot Flame Appearance
Use the remote to adjust the flame height as desired.
Propane models may exhibit a flame pattern that may "candle" or appear stringy. If this is prob­lematic or persists as the appliance is continually operated, close the air shutter, as described here. Operate the appliance for a period of time as the effect diminishes, ensuring that the appliance does not develop sooty flames. When satisfied that the appliance operates properly, proceed to finish the installation.
45
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
Page 46
Innovative Hearth Products
Electrode
Flame
Main Power Cord
ELECTRONIC WIRING DIAGRAM
(Schematic representation only)
DRT/DRC6300 Series Direct-Vent Gas Fireplaces
Operation
900343-01 11/2015
ORDERING REPLACEMENT PARTS
A complete parts list is found at the end of this manual. Use only parts supplied from the manufacturer.
With proper care and maintenance, your appli­ance will provide many years of enjoyment. If you should experience any problem, first refer to the troubleshooting guide in this manual. If problem persists, contact your Innovative Hearth Products dealer or distributor.
Normally, all parts should be ordered through your Innovative Hearth Products distributor or dealer.
Parts will be shipped at prevailing prices at time of order.
WIRING
Wiring diagrams are provided here for refer­ence purposes only. This information is also provided on schematics attached directly to the appliance on a pullout panel located within the control compartment.
When ordering repair parts always provide:
1. The model number of the appliance.
2. The serial number of the appliance.
3. The part number.
4. The description of the part.
5. The quantity required.
6. The installation date of the appliance.
PRODUCT REFERENCE INFORMATION
We recommend that you record the important reference information about your fireplace in the space provided below.
Please call Innovative Hearth Products for the phone number of your nearest Innovative Hearth Products dealer who will answer your questions
or address your concerns. If you encounter any problems or have any questions concerning the installation or ap­plication of this system, please contact your dealer or distributor.
INNOVATIVE HEARTH PRODUCTS
1508 Elm Hill Pike, Suite 108
Nashville, TN 37210
Visit us at
SuperiorFireplaces.US.com
Fireplace Model Number ________________________________________________ Fireplace Serial Number _________________________________________________ Date Installed _________________________________________________________ Type of Gas Used in Fireplace ____________________________________________ Dealer Name _________________________________________________________
CAUTION: LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS APPLIANCE OPERATION.
ATTENTION : AU MOMENT DE
L'ENTRETIEN DES COMMANDES,
ÉTIQUETEZ TOUS LES FILS AVANT DE
LES DÉBRANCHER. DES ERREURS DE
CÁBLAGE PEU-VENT ENTRAÎNER UN
FONCTIONNEMENT INADÉQUAT ET
DANGEREUX.
SCHEMATIC REPRESENTATION ONLY
COLOR CODE: B = Black BB = Brown w/Black Stripe BG = Brown w/Green Stripe BL = Blue BR = Brown G = Green GY = Gray O = Orange R = Red W = White Y = Yellow
Note: On models without pressure
switch, these
connectors are
plugged together.
BR
Air Pressure Switch
Power Vent Only
Main Wire
Harness
G
Y
Battery Holder with Switch
Battery Holder w/Switch ON/ Remote /OFF
Y
Battery Holder Wire Harness
GY
ON/Remote/OFF
B
O
R
BL
O
G
IPI Pilot
Pilot Tube
Optional
885 Valve
BL
G
W
R
B
R
B
WH
B
W
G
Split Flow
Reset Switch
(See instructions.)
B
Control Module
Fuse
B
B
Sensor
Spark
B
Ground Y
G
W
46
Figure 75—Wiring Diagram
Power Vent Blower
Power Vent
Models Only
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
Page 47
Innovative Hearth Products DRT/DRC6300 Series Direct-Vent Gas Fireplaces
ACCESSORY COMPONENTS
Bag of Glowing Embers Bag of Volcanic Stone Bag of Platinum Embers
Replacement ember material, volcanic stone and vermiculite are available for use with these appliances. Order them to replace materials as part of the periodic maintenance of the appliance.
Firebox Accessories/Parts
Cat. No. Model Description
88L53 FGE Bag of Glowing Embers 80L42 FDVS Bag of Volcanic Stone H8312 PGE Bag of Platinum Embers
Firebox Liner Kits
Choose from ceramic brick or porcelain panels.
Ceramic and Porcelain Firebox Liner Kits
Fireplace Cat. No. / Model Description
40 in.
45 in.
H8697 LKC-BFRS-MDLX40
H8698 LKC-RDRS-MDLX40
H2220 BLKH-LSM40
H4803 BLK-REDH-LSM40
H8581 LKP-BK-MDLX40
H8699 LKC-BFRS-MDLX45
H8700 LKC-RDRS-MDLX45
H2224 BLKH-LSM45
H4804 BLK-REDH-LSM45
H8696 LKP-BK-MDLX45
Ceramic, Buff Rustic
Ceramic, Red Rustic
Ceramic, Buff Herringbone
Ceramic, Red Herringbone
Porcelain, Black
Ceramic, Buff Rustic
Ceramic, Red Rustic
Ceramic, Buff Herringbone
Ceramic, Red Herringbone
Porcelain, Black
Operation
900343-01 11/2015
P
A
T
I
N
Touch-Up Paint Kit
Repair of minor scratches and discoloration of the appliances black painted surfaces may be accom­plished with the touch-up paint kit.
Touch-Up Paint Kit
Cat.
No.
F1881 SCITPSAB
F1882 SCTPSAB
Model Description
Black touch-up paint, firebox interior
Black touch-up paint, powder coat exterior
Log Sets
This finely crafted log set has detailing that replicates the natural look of real wood.
Oak Log Set
Cat. No. Model Description
H8676 LOG-OAK-
MDLX4045
Oak Log Set
Glass Media Kits
Reflective Black
Reflective Blue Platinum
Cat. No. Model Description
H8412 CRSHGL-RBLK Reflective Black H8424 CRSHGL-RBLU Reflective Blue H8413 CRSHGL-P Platinum H8538 CRSHGL-GF Goldfinger H8539 CRSHGL-C Copper
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
Goldfinger
Copper
47
Page 48
Innovative Hearth Products DRT/DRC6300 Series Direct-Vent Gas Fireplaces
Operation
900343-01 11/2015
Mission
Classic
Andiron Grate Kits
The andiron kits attach to the grate assembly.
Andiron Grate Kits
Fits
Fireplace
Models
40" & 45"
Models
Cat. No. (Model)
Mission Classic
H2227
(AKM-LSM)
H2228
(AKC-LSM)
Dual Arch Screen Kits
These Dual Arch screen kits can be placed in front of the glass enclosure panel to help prevent direct human contact with the hot glass surface.
Dual Arch Screen Kits
Cat. No. Model Description
H5051 DASK-LSM40-2 Dual Arch
H5054 DASK-LSM45-2 Dual Arch
Screen
Screen
Barrier Kits
Classic Screen Kits
These Classic Screen kits can be placed in front of the
glass enclosure panel to help prevent direct human
contact with the hot glass surface.
Classic Screen Kits
Cat. No. Model Description
H5052 SK-LSM40-2 Classic Screen Kit H5055 SK-LSM45-2 Classic Screen Kit
48
A Barrier is installed by the manufacturer and required to be installed during operation of the fireplace. If the Barrier becomes damaged, discontinue operation of the fireplace until the Barrier is replaced with the approved Barrier listed below.
Barrier Kits
Cat. No. Description
J7422 40" Barrier J7423 45" Barrier
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
Page 49
Innovative Hearth Products
9-5/8"
DRT/DRC6300 Series Direct-Vent Gas Fireplaces
WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
Operation
900343-01 11/2015
FOR YOUR SAFETY READ BEFORE OPERATING
A. This appliance is equipped with an ignition device which automatically lights
the pilot. Do not try to light the pilot by hand.
B. BEFORE OPERATING smell all around the appliance area for gas. Be sure to
smell next to the floor because some gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS:
• Donottrytolightanyappliance.
• Donottouchanyelectricswitch;donotuseanyphoneinyourbuilding.
• Immediatelycallyourgas supplier from aneighbor’sphone. Followthegas
supplier’s instructions.
• Ifyoucannotreachyourgassupplier,callthefiredepartment.
C. If any portion of this appliance does not operate as the instructions indicate,
do not try to repair it, call a qualified service technician. Do not use tools. Force or attempted repair may result in a fire or explosion.
D. Do not use this appliance if any part has been under water. Immediately call
a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
OPERATING INSTRUCTIONS
1. STOP! Read the safety information above on this label.
2. Read the Care and Operation manual including the section on "Remote Control System."
3. Slide the switch on the receiver to "OFF."
4. Press ON/OFF button on remote control transmitter to "OFF."
5. Turn "OFF" all electric power to the appliance.
6. This appliance is equipped with an ignition device which automatically lights the pilot. Do not try to light the pilot by hand.
7. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information above on this label. If you don’t smell gas, go to the next step.
8. Turn on all electric power to the appliance.
9. Slide the switch on the receiver to REMOTE.
10. Press ON/OFF button on remote control transmitter to "ON."
11. (if applicable)
12. If the appliance will not operate, follow the instructions "To Turn Off Gas To Appliance" and call your service technician or gas supplier.
Set thermostat on remote control to desired setting.
Electronic Gas Control
Valve - SIT Proflame
Receiver
PRG
On
Remote
Off
Electronic Pilot Assembly
Remote Control
Transmitter
ON/OFF Key THERMOSTAT Key UP/DOWN Arrow Key
MODE Key
TO TURN OFF GAS TO APPLIANCE
1. Slide the switch on the receiver to "OFF."
2. Press ON/OFF button on remote control transmitter to "OFF."
DANGER
3. Turn off all electric power to the appliance if service is to be performed.
4. Close the main line gas shut-off valve.
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed for the protection of children and other at-risk individuals.
P/N 900335-00, Rev. 0
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
49
Page 50
Innovative Hearth Products
9-5/8"
DRT/DRC6300 Series Direct-Vent Gas Fireplaces
POUR PLUS DE SÉCURITÉ LIRE AVANT DE METTRE EN MARCHE
AVERTISSEMENT. Quiconque ne respecte pas à la lettre les instructions dans la présente notice risque de déclencher un incendie ou une explosion entraînant des dommages, des blessures ou la mort.
Operation
900343-01 11/2015
A. Cet appareil est muni d’un dispositif d’allumage qui allume
automatiquement la veilleuse. Ne tentez pas d’allumer la veilleuse manuellement.
B. AVANT DE FAIRE FONCTIONNER, reniflez tout autour de l’appareil pour
déceler une odeur de gaz. Reniflez près du plancher, car certains gaz sont plus lourds que l’air et peuvent s’accumuler au niveau du sol.
QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ :
• Ne pas tenter d’allumer d’appareil.
• Ne touchez à aucun interrupteur; ne pas vous servir des téléphones se
trouvant dans le bâtiment.
• Appelez immédiatement votre fournisseur de gaz depuis un voisin. Suivez les
instructions du fournisseur.
• Si vous ne pouvez rejoindre le fournisseur, appelez le service des incendies.
C. Si un élément de cette unité ne fonctionne pas tel que décrit dans les
instructions, n’essayez pas de le réparer, appelez un technicien qualifié. N’utilisez-pas d’outils. Le fait de forcer la manette ou de la réparer peut déclencher une explosion ou un incendie.
D. N’utilisez pas cet appareil s’il a été plongé dans l’eau, même partiellement.
Faites inspecter l’appareil par un technicien qualifié et remplacez toute partie du système de contrôle et toute commande qui ont été plongés dans l’eau.
INSTRUCTIONS DE MISE EN MARCHE
1. ARRÊTEZ ! Lisez les avertissements de sécurité à l’endos de cette étiquette.
2. Lisez le manuel d’utilisation et d’entretien incluant la section « Système de télécommande ».
3. Placez l’interrupteur du récepteur en position “OFF”.
4. Appuyez sur le bouton “ON/OFF” pour sélectionner “OFF”.
5. Coupez l’alimentation électrique de l’appareil.
6. Cet appareil est muni d’un dispositif d’allumage qui allume automatiquement la veilleuse. Ne tentez pas d’allumer la veilleuse manuellement.
7. Attendre cinq (5) minutes pour laisser échapper tout le gaz. Reniflez tout autour de l’appareil, y compris près du plancher, pour déceler une odeur de gaz. Si vous sentez une odeur de gaz, ARRÊTEZ ! Passez à l’étape B des instructions de sécurité sur la portion supérieure de cette étiquette. S’il n’y a pas d’odeur de gaz, passez à l’étape suivante.
8. Mettez l’appareil sous tension.
9. Placez l’interrupteur du récepteur en position “REMOTE”.
10. Appuyez sur le bouton “ON/OFF” pour sélectionner “ON”.
11.
(Si applicable) désiré.
12. Si l’appareil ne se met pas en marche, suivez les instructions intitulées « Comment couper l’admission de gaz de l’appareil » et appelez un technicien qualifié ou le fournisseur de gaz.
Ajustez le thermostat sur la télécommande à l’ajustement
Valve électronique -
SIT Proflame
Récepteur
On
Remote
Off
PRG
Module de veilleuse
électronique
Télécommande
Bouton ON/OFF Bouton THERMOSTAT
50
COMMENT COUPER L’ADMISSION DE GAZ DE L’APPAREIL
1. Coupez l’alimentation électrique de l’appareil s’il faut procéder à l’entretien.
2. Sélectionnez OFF sur le récepteur.
DANGER
3. Appuyez sur le bouton ON/OFF et sélectionnez OFF.
4. Fermer la valve de gaz principale.
VITRE CHAUDE
RISQUE DE BRÛLURES.
NE TOUCHEZ PAS UNE VITRE
NON REFROIDIE.
NE LAISSEZ JAMAIS UN ENFANT
DE TOUCHER LA VITRE.
L'écran pare-étincelles fourni avec ce foyer réduit le risque de brûlure en cas de contact accidentel avec la vitre chaude et doit être installé pour la protection Des enfants et Des personnes à risques.
P/N 900336-00, Rev. 0
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
Page 51
Innovative Hearth Products DRT/DRC6300 Series Direct-Vent Gas Fireplaces
MAINTENANCE SCHEDULE Turn off gas and electrical power to the fireplace and allow it to cool before cleaning or servicing the appliance.
Annually (Before the onset of the Burning Season) MAINTENANCE TASK ACCOMPLISHING PERSON PROCEDURE
Operation
900343-01 11/2015
Inspect/Clean Burner, Logs, and Controls
Qualified Service Technician Inspect valve and ensure it is properly operating. Check piping for
leaks. Vacuum the control compartment, fireplace logs, and burner area.
Check Flame Patterns and Flame Height
Qualified Service Technician Refer to Figure 13 or Figure 14 on Page 20.Verify the flame pattern
and height displayed by the appliance conforms to the picture. Flames must not impinge on the logs. Ensure flames are steady (not lifting or floating).
Inspect/Clean Pilot and Burner Qualified Service Technician Refer to Figure 15 on Page 20. Remove any surface build-up on the
pilot and burner assembly. Wipe the pilot nozzles, igniter/flame rod, and hood. Ensure the pilot flame engulfs the flame sensor as shown.
Check Vent System Qualified Service Technician Inspect the vent system at the top and at the base (within the firebox)
for signs of blockage or obstruction. Look for any signs of dislocation or deterioration of the vent components.
NOTE: Excessive condensation can cause corrosion of caps, pipe & fittings (excessive condensation can be caused by long lateral runs, too many elbows, and/or exterior portions of the system being exposed to cold weather). Also, inspect the wall straps or plumbers's tape to ensure they are securely in place.
Appliance Checkout Qualified Service Technician Perform the appropriate appliance checkout procedure detailed in this
manual.
Replace Glowing Embers Homeowner/Qualified Service
Technician
Remove old ember materials (rockwool) and vacuum the ember placement area. Place new embers per instructions on Page 11.
Periodically (After the Burning Season) MAINTENANCE TASK ACCOMPLISHING PERSON PROCEDURE
Clean Firebox Interior Homeowner Carefully remove logs, rockwool, and volcanic stone. Vacuum out
interior of the firebox. Clean firebox walls and log grate. Replace logs, glowing embers (rockwool), and volcanic stone as detailed in this manual.
Check Flame Patterns and Flame Height
Check Vent System Homeowner Inspect the vent system at the top and at the base (within the firebox)
Clean Front Glass Enclosure Panel Homeowner Clean as necessary following the directions provided in this manual.
Homeowner Refer to Figure 13 and Figure 14 on Page 20. Verify the flame
pattern and height displayed by the appliance conforms to the picture. Flames must not impinge on the logs.
for signs of blockage or obstruction. Look for any signs of dislocation of the vent components (reconnect or replace as necessary).
Do not touch or attempt to clean glass while hot.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
51
Page 52
Innovative Hearth Products DRT/DRC6300 Series Direct-Vent Gas Fireplaces
900343-01 11/2015
Operation
TROUBLESHOOTING GUIDE
NOTE: Before troubleshooting, be sure that the appliance main line gas shut-off valve and the wall switch are in the “ON” position. The following troubleshoots the fireplace only to an elementary level. For detailed Remote and Ignition System troubleshooting, refer to the instructions provided with the remote.
IMPORTANT: Detailed valve system troubleshooting should only be accomplished by a qualified service technician.
SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION
Nothing happens when the fireplace is turned on or off.
The main burner does not light and the igniter is sparking.
The burner lights, then immediately goes out.
Log and glass soot Flame impingement on the top log. Check for proper log placement.
Remote control system is not functioning properly.
Unit is not receiving power. Check/replace batteries behind the wall switchplate.
Gas is not reaching the fireplace. Check the gas supply and gas shutoff valves (call a
Gas is not reaching the fireplace. Check the gas supply and gas shutoff valves (call a
Loose wires to the valve. Check control compartment for any obvious loose
Loose wires to ignition module. Check control compartment for any obvious loose
Air in the gas line. Purge gas line of air (call a service technician). Gas is not reaching the fireplace. Check the gas supply and gas shutoff valves (call a
Loose wires to the valve or ignition module. Check the gas supply and gas shutoff valves (call a
Pilot flame is not engulfing the sensor. Call a service technician. Obstructed vent system. Call a service technician.
Improper Air shutter opening. Check for proper air shutter openings.
To use the remote control system, the wall switch plate must be set to REMOTE.
Manually operate the fireplace using the wall switch (ON/OFF).
Replace the batteries in the handheld remote and/or behind the wall switchplate.
Check building circuit breakers to ensure power is on to the fireplace.
service technician, if required).*
service technician, if required).*
wiring (call a service technician).
wiring (call a service technician).
service technician, if required).*
service technician, if required).*
*The unit may have multiple gas supply shutoffs (the main gas supply valve in the house, the gas supply valve in the fireplace control compart­ment, and/or an additional shutoff valve near the fireplace).
52
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
Page 53
Innovative Hearth Products DRT/DRC6300 Series Direct-Vent Gas Fireplaces
REPLACEMENT PARTS LIST
Operation
900343-01 11/2015
Item
Description
No.
1 Door Modesty Shield H4808 1 H4809 1
--- Log Set (Oak) (Traditional) H8676 1 H8676 1 3 Enclosure, Glass Door H2281 1 H2282 1 4 Spring Latch Assembly H2274 2 H2274 2 5 Burner Assembly, Traditional H4817 1 H4817 1 5 Burner Assembly, Contemporary F1880 1 F1880 1 6 Venturi (Traditional) H1428 1 H1428 1
--- Gasket—Venturi (Traditional) 43K85 1 43K85 1 8 Access Plate H2277 1 H2277 1 9 Barrier J7422 1 J7423 1
--- Barrier Filler J7990 1 J7991 1
11 Gasket, Access Plate H1452 1 H1452 1 12 Gas Line Tubing H2283 1 H2284 1 13 Connector, Male H2285 1 H2285 1 14 Orifice, Natural Gas, Traditional H2286 1 J8001 1 14 Orifice, Propane Gas, Traditional J8002 1 H2287 1 14 Orifice, Natural Gas, Contemporary H2286 1 J8001 1 14 Orifice, Propane Gas, Contemporary H8807 0 H8807 1 16 Bag of Glowing Embers (Traditional) 88L53 1 88L53 1 17 Grate Assembly H4907 1 H4907 1 18 Gas Line, Flexible Connection 93L32 1 93L32 1 19 Modesty Panel, Right Side J8152 1 J8153 1 20 Modesty Panel, Left Side J8154 1 J8155 1 21 Access Door J8156 1 J8156 1
--- Floor Panel H3369 1 H3370 1 22 Bag of Volcanic Stone (Traditional) 80L42 1 80L42 2 23 Bag of Platinum Embers
(Traditional)
--- Springs J7542 1 J7542 1
--- Access Door J7541 1 J7541 1
--- Insulation J7544 1 J7544 1
--- Top Channel J7545 1 J7545 1
--- Heat Baffle J7548 1 J7548 1
--- Header Heat Shield J7549 1 J7549 1
40 in. 45 in.
Cat. No. Qty. Cat. No. Qty.
H8312 1 H8312 1
Gas Controls—SIT Electronic
Item
Description
No.
30 Gas Valve, SIT H7270 1 H7271 1 31 Pilot Assembly H7268 1 H7269 1 32 Control Module H8656 1 H8656 1
--- Wiring Harness, Power H8811 1 H8811 1
--- Wiring Harness, Control H8814 1 H8814 1
--- Wiring Harness, Wall Switch H8813 1 H8813 1
--- Wiring Harness, Jumper H8809 1 H8809 1
Natural Gas Propane Gas
Part
Qty. Part No. Qty.
No.
WARNING
Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury.
AVERTISSEMENT
Risque de dommages ou de blessures si les pièces ne sont pas installées conformément à ces schémas et ou si des pièces autres que celles spécifiquement approuvées avec cet appareil sont utilisées.
Contact an Innovative Hearth Products dealer to obtain any of these parts. Never use substitute materials. Use of non-approved parts can result in poor performance and safety hazards.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
53
Page 54
Innovative Hearth Products
30
16
22
23
7
18
13
12
6
8
11
5
1
4
17
3
9
25
20
19
31
32
31
14
HI
LO
DRT/DRC6300 Series Direct-Vent Gas Fireplaces
REPLACEMENT PARTS
Operation
900343-01 11/2015
21
54
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
Page 55
Innovative Hearth Products
®
Superior
Brand Gas Fireplaces, Stoves and Inserts
20 Year Limited Warranty
THE WARRANTY
Innovative Hearth Products ("IHP") 20 Year Limited Warranty warrants your Superior® Brand gas fi replace, Stove or Insert ("Product") to be free from defects in materials and workmanship at the time of manufacture. The Product body and fi rebox carry the 20 Year Limited Warranty. Ceramic glass carries the 20 Year Limited Warranty against thermal breakage only. After installation, if covered components manufactured by IHP are found to be defective in materials or workmanship during the 20 Year Limited Warranty period and while the Product remains at the site of the original installation, IHP will, at its option, repair or replace the covered components. If repair or replacement is not commercially practical, IHP will, at its option, refund the purchase price or wholesale price of the IHP product, whichever is applicable. IHP will also pay IHP prevail­ing labor rates, as determined in its sole discretion, incurred in repairing or replacing such components for up to fi ve years. THERE ARE EXCLUSIONS AND LIMITATIONS to this 20 Year Limited Warranty as described herein.
COVERAGE COMMENCEMENT DATE
Warranty coverage begins on the date of purchase. In the case of new home construction, warranty coverage begins on the date of fi rst occupancy of the dwelling or six months after the sale of the Product by an independent IHP dealer/distributor, whichever occurs earlier. The warranty shall commence no later than 24 months following the date of product shipment from IHP, regardless of the installation or occupancy date.
EXCLUSIONS AND LIMITATIONS
This 20 Year Limited Warranty applies only if the Product is installed in the United States or Canada and only if operated and maintained in accordance with the printed instructions accompanying the Product and in compliance with all applicable installation and building codes and good trade practices.
This warranty is non-transferable and extends to the original owner only. The Product must be purchased through a listed supplier of IHP and proof of purchase must be provided. The Product body and fi rebox carry the 20 Year Limited Warranty from the date of installation. Vent components, trim components and paint are excluded from this 20 Year Limited Warranty. The following do not carry the 20 Year Limited Warranty but are warranted as follows:
Burner – Repair or replacement for one year from the date of installation Gas components – Repair or replacement for one year from the date of installation Gaskets – Repair or replacement for one year from the date of installation Logs – Replacement for one year from the date of installation against thermal breakage only Optional blowers & remote controls – Repair or replacement for one year from the date of installation Optional glass doors – Repair or replacement for 90 days from the date of installation Tempered glass - Replacement for one year from the date of installation Labor coverage – Prevailing IHP labor rates apply for the warranty period of the component
Parts not otherwise listed carry a 90 day warranty from the date of installation.
Whenever practicable, IHP will provide replacement parts, if available, for a period of 10 years from the last date of manufacture of the Product.
IHP will not be responsible for: (a) damages caused by normal wear and tear, accident, riot, fi re, fl ood or acts of God; (b) damages caused by abuse, negligence, misuse, or unauthorized alteration or repair of the Product affecting its stability or performance (The Product must be subjected to normal use. The Product is designed to burn either natural or propane gas only. Burning conventional fuels such as wood, coal or any other solid fuel will cause damage to the Product, will produce excessive temperatures and could result in a fi re hazard.); (c) damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with the Product; (d) damages, repairs or ineffi ciency resulting from faulty installation or application of the Product.
IHP is not responsible for inadequate fi replace system draft caused by air conditioning and heating systems, mechanical ventilation systems, or general construction condi­tions which may generate negative pressure in the room in which the appliance is installed. Additionally IHP assumes no responsibility for drafting conditions caused by venting confi gurations, adjoining trees or buildings, adverse wind conditions or unusual environmental factors and conditions that affect the operation of the unit.
This 20 Year Limited Warranty covers only parts and labor as provided herein. In no case shall IHP be responsible for materials, components or construction, which are not manufactured or supplied by IHP or for the labor necessary to install, repair or remove such materials, components or construction. Additional utility bills incurred due to any malfunction or defect in equipment are not covered by this warranty. All replacement or repair components will be shipped F.O.B. from the nearest stocking IHP factory.
LIMITATION ON LIABILITY
It is expressly agreed and understood that IHP’s sole obligation and the purchaser’s exclusive remedy under this warranty, under any other warranty, expressed or implied, or in contract, tort or otherwise, shall be limited to replacement, repair, or refund, as specifi ed herein.
In no event shall IHP be liable for any incidental or consequential damages caused by defects in the Product, whether such damage occurs or is discovered before or after repair or replacement, and whether such damage is caused by IHP’s negligence. IHP has not made and does not make any representation or warranty of fi tness for a particular use or purpose, and there is no implied condition of fi tness for a particular use or purpose.
IHP makes no expressed warranties except as stated in this 20 Year Limited Warranty. The duration of any implied warranty is limited to the duration of this expressed warranty.
No one is authorized to change this 20 Year Limited Warranty or to create for IHP any other obligation or liability in connection with the Product. Some states and provinces do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. The provisions of this 20 Year Limited Warranty are in addition to and not a modifi cation of or subtraction from any statutory warranties and other rights and remedies provided by law.
INVESTIGATION OF CLAIMS AGAINST WARRANTY
IHP reserves the right to investigate any and all claims against this 20 Year Limited Warranty and to decide, in its sole discretion, upon the method of settlement.
To receive the benefi ts and advantages described in this 20 Year Limited Warranty, the appliance must be installed and repaired by a licensed contractor approved by IHP.
Contact IHP at the address provided herein to obtain a listing of approved dealers/distributors. IHP shall in no event be responsible for any warranty work done by a
contractor that is not approved without fi rst obtaining IHP's prior written consent.
HOW TO REGISTER A CLAIM AGAINST WARRANTY
In order for any claim under this warranty to be valid, you must contact the IHP dealer/distributor from which you purchased the product. If you cannot locate the dealer/ distributor, then you must notify IHP in writing. IHP must be notifi ed of the claimed defect in writing within 90 days of the date of failure. Notices should be directed to the IHP Warranty Department at 1508 Elm Hill Pike, Suite 108; Nashville, TN 37210 or visit our website at WWW.SUPERIORFIREPLACES.US.COM.
Printed in U.S.A. © 2013 Innovative Hearth Products
P/N 900223-00, Rev. A 10/2015
Innovative Hearth Products 1508 Elm Hill Pike, Suite 108 • Nashville, TN 37210
55
Page 56
Innovative Hearth Products
P900343-01
DRT/DRC6300 Series Direct-Vent Gas Fireplaces
Installation and Operation Instructions
900343-01 11/2015
Contact an IHP dealer to obtain any of these parts. Please contact IHP for the phone number of your nearest IHP dealer. SuperiorFireplaces.us.com Record the following important information about your fireplace:
Fireplace model number
Fireplace serial number
Date fireplace was Installed
Type of gas fireplace uses
Dealer name
Innovative Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discon­tinue colors, styles and products. Consult your local distributor for fireplace code information.
Printed in U.S.A. © 2014 Innovative Hearth Products P/N 900343-01 Rev. C 11/2015