Superior DRT35STDMN, DRT35STDMP, DRT35STDEN, DRT35PFDMN, DRT35PFDMP, DRT35PFDEN Installation And Operation Instructions Manual
Specifications and Main Features
Frequently Asked Questions
User Manual
P/N 900300-00 Rev. NC 02/2015
PFS
USC
Ce manuel est disponible en francais, simplement
en faire la demande. Numéro de la pièce 900300-02.
P900300-00
®
Report No. F14-165
Installation and Operation Instructions
SuperiorTM DRT35 See Through and Peninsula Direct
Vent Gas Fireplaces
Models
DRT35STDMN
DRT35STDMP
DRT35STDEN
DRT35PFDMN
DRT35PFDMP
DRT35PFDEN
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
Installateur : Laissez cette notice avec l’appareil.
Consommateur : Conservez cette notice pour
consultation ultérieure.
A barrier designed to reduce the risk of burns from
the hot viewing glass is provided with this appliance
and shall be installed for the protection of children
and other at-risk individuals.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile
home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the
rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
Cet appareil peut installé dans une maison préfabriquée (mobile) déjà installée à demeure, si les réglements
locaux le permettent. Ce appareil doit être utilisé uniquement avec le type de gaz indiqué sure la plaque
signalétique. Cet appareil ne peut être converti à d’autres gaz, sauf si une trousse de conversion est utilsée.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result
in serious injury, death, or property damage.
— Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire
department.
— Installation and service must be performed by a
qualified installer, service agency or the gas supplier.
L’écran pare-étincelles fourni avec ce foyer réduit le
risque de brûlure en cas de contact accidentel avec
la vitre chaude et doit être installé pour la protection
Des enfants et Des personnes à risques.
AVERTISSEMENT:
RISQUED’INDENDIE OU D’EXPLOSION
Le non-respect Des avertissements de sécurité
pourrait d’entraîner des blessures graves, la mort
ou des dommages matériels.
— Ne pas entreposer ni utilizer d’essence ni d’autres
vapeurs ou liquides inflammables dans le voisinage de cet appareil ou de tout autre appareil.
— QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d’allumer d’appareil.
• Ne touchez à aucan interrupteur. Ne pas vous
servir des téléphones se trouvant dans le bâtiment où vous trouvez.
• Sortez immédiatement de bâtiment.
• Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions du
fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de
gaz, appelez le service des incindies.
— L’installation et l’entretien doivent être assurés par
un installateur ou un service d’entretien qualifié
ou par le fournisseur de gaz.
DANGER
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
A barrier designed to reduce the risk of burns from the hot viewing glass
is provided with this appliance and shall be installed for the protection of
children and other at-risk individuals.
See attached color flyer for proper color representation
DANGER
VITRE CHAUDE
RISQUE DE BRÛLURES.
NE TOUCHEZ PAS UNE VITRE
NON REFROIDIE.
NE LAISSEZ JAMAIS UN ENFANT
DE TOUCHER LA VITRE.
L’écran pare-étincelles fourni avec ce foyer réduit le risque de brûlure en
cas de contact accidentel avec la vitre chaude et doit être installé pour la
protection Des enfants et Des personnes à risques.
Voir ci-joint tract pour une bonne représentation de la couleur
PELIGRO
EL VIDRIO CALIENTE
CAUSARÁ QUEMADURAS.
USTED DEBE NUNCA
TOCAR EL VIDRIO CALIENTE.
LOS NIÑOS DEBEN NUNCA
TOCAR EL VIDRIO.
Una barrera diseñada para reducir el riesgo de quemaduras desde la mirilla (vidrio) caliente es proveida con este aparato y deberá instalarse para
la protección de los niños y otros individuos en riesgo.
Vea el volante adjunto para la representación de color adecuado
Innovative Hearth Products
SuperiorTM DRT35 See Through and Peninsula Direct Vent Gas Fireplace
General Information
900300-00, 02/2015
Safety and Your
Fireplace
All parts of your
IHP fireplace get
EXTREMELY HOT!
To prevent severe
burns and injuries,
install a screen or
physical barrier to
prevent direct contact
with the glass.
Follow the safety instructions
below and be sure everyone in
your household understands this
burn hazard:
• The surfaces on your fireplace get
EXTREMELY HOT!
• The glass on the front of the
fireplace reaches EXTREMELY
HIGH temperatures and can cause
severe burns if touched.
• Keep children away from an
operating fireplace. Closely
supervise children in any room
where a fireplace is operating to
prevent contact with glass.
• Keep clothing, furniture,
gasoline, and other flammable
liquids away from the fireplace.
• Even after the gas is turned
off, fireplace surfaces remain
extremely hot.
Be sure to attach the enclosed
Safety-in-Operation Warnings where
you turn on your fireplace, to help
remind everyone of the dangers
associated with high temperatures
(Page 38).
Read Important Safety Information
(Page 4)
3
Toutes les parties de votre
EXTRÊMEMENT CHAUDES !
La sécurité et
votre foyer
foyer IHP deviennent
Afin d'éviter de vous
brûler gravement ou de
vous blesser, installez
une grille ou une barrière
physique pour empêcher
tout contact direct avec la vitre.
Suivez les instructions de sécurité
ci-dessous et veillez à ce que tous les
membres de votre famille soient conscients
du danger de brûlure encouru :
• Les surfaces de votre foyer deviennent
EXTRÊMEMENT CHAUDES !
• La vitre située à l'avant du
foyer atteint des températures
EXTRÊMEMENT ÉLEVÉES et peut
causer de graves blessures en
cas de contact.
• Tenez les enfants à l'écart
du foyer lorsqu'il fonctionne.
Surveillez attentivement les
enfants dans les pièces où un
foyer est utilisé afin d'éviter qu'ils
ne soient en contact avec la vitre.
• Tenez tous les vêtements, les
meubles, l'essence et tout autre liquide
inflammable à l'écart du foyer.
• Même après fermeture du gaz,
les surfaces du foyer restent
extrêmement chaudes.
Veillez à coller les Étiquettes de mise
en garde relatives à la sécurité
d'utilisation à l'endroit où vous
utilisez le foyer, pour rappeler à tous
les utilisateurs les dangers liés aux
températures élevées (Page 38).
Lisez L’information de sûreté
importante (Page 4).
[FRENCH][ENGLISH]
Seguridad y su
chimenea
¡Todas las partes de la
chimenea IHP se ponen
MUY CALIENTES!
Instale una malla o barrera física para evitar
el contacto directo con el vidrio y prevenir
las quemaduras y lesiones graves.
Siga las instrucciones de seguridad
a continuación y asegúrese de que
todos en su hogar sepan acerca de
este peligro de quemadura:
• ¡Las superficies de la chimenea
se ponen MUY CALIENTES!
• El vidrio delante de la
chimenea alcanza temperaturas
EXTREMADAMENTE ALTAS
y puede causar quemaduras
graves si se toca.
• Mantenga a los niños alejados de
la chimenea en funcionamiento.
Supervise en forma cercana a los
niños en cualquier cuarto donde haya
una chimenea funcionando para
impedir el contacto con el vidrio.
• Mantenga la ropa, mobiliario,
gasolina y otros líquidos
inflamables alejados de la
chimenea.
• Aún después de haber apagado
el gas, las superficies de
la chimenea permanecen
extremadamente calientes.
Asegúrese de colocar las Etiquetas
de advertencia de seguridad
de operación en el lugar donde
enciende la chimenea, para que todos
recuerden los peligros asociados con
las altas temperaturas (Página 38).
Lea Información importante de
seguridad (Página 4).
[SPANISH]
Innovative Hearth Products
SuperiorTM DRT35 See Through and Peninsula Direct Vent Gas Fireplace
The assembled vented gas fireplace heater is
packaged with:
1 - the logs are packaged in a carton located
2 - one plastic bag of glowing embers is located
3 - one envelope containing the literature
4 - one vent restrictor to be applied as shown on
5 - two hoods on see through units and three
6 - top standoffs taped to top of unit
7 - front face assemblies with barriers.
NOTE:
• If the barrier becomes dam-
• For use with barrier(s) Part
INTRODUCTION
The Millivolt appliances have a millivolt gas
control valve with piezo ignition system. If any
optional accessories that will require electrical
power are to be installed, the electrical power
must be provided at the time of appliance
installation.
The Electronic appliances are designed to operate on natural or propane gas. An electronic
intermittent pilot ignition system provides safe,
efficient operation. External electrical power is
required to operate these units.
These vented gas fireplace heaters are sealed
combustion, air-circulating gas fireplaces designed for residential applications.
Approved Vent Components - These fireplaces
are designed, tested and listed for operation
and installation with the following vent components only:
•Secure Vent™ Direct-Vent System Compo-
•Secure Flex™ Flexible Vent Components
Please read and understand these
instructions before beginning your
installation.
4
•Z-FLEX™ Model GA Venting Systems listed
Use only the correct size venting (4-1/2" inner
and 7-1/2" outer).
These approved vent system components are
labeled for identification. DO NOT use any
other manufacturer’s vent components with
these appliances.
within the firebox.
in the bottom compartment.
package which consists of Installation Instructions and Care and Operations manual
(IICO) with warning labels and warranty;
envelope is located in the bottom compartment.
page 14 ; restrictor is taped to the envelope.
hoods on peninsula fireplaces
aged, the barrier shall be replaced with the manufacturer’s
barrier for this appliance.
No(s). J7424 (ST Models) and
J7424 and J7425 (PF Models).
nents manufactured by Security Chimneys
International,
manufactured by Security Chimneys International and
to UL1777 and ULCS635 manufactured by
Flexmaster Canada Limited.
Installation and Operation Instructions
900300-00, 02/2015
GENERAL INFORMATION
WARNING
Young children should be carefully supervised when they are
in the same room as the appliance. Toddlers, young children
and others may be susceptible
to accidental contact burns. A
physical barrier is recommended
if there are at risk individuals in
the house. To restrict access to
a fireplace or stove, install an
adjustable safety gate to keep
toddlers, young children and
other at risk individuals out of
the room and away from hot
surfaces.
AVERTISSEMENT
Les jeunes enfants devraient être
surveillés étroitement lorsqu’ils
se trouvent dans la même pièce
que l’appareil. Les tout petits,
les jeunes enfants ou les adultes
peuvent subir des brûlures s’ils
viennent en contact avec la surface chaude. Il est recommandé
d’installer une barrière physique
si des personnes à risques habitent la maison. Pour empêcher
l’accès à un foyer ou à un poêle,
installez une barrière de sécurité; cette mesure empêchera les
tout petits, les jeunes enfants et
toute autre personne à risque
d’avoir accès à la pièce et aux
surfaces chaudes.
Children and adults should be alerted to the
hazards of high surface temperature and
should stay away to avoid burns or clothing
ignition.
Les enfants et les adultes devraient être informés des dangers que posent les températures
de surface élevées et se tenir à distance afin
d’éviter des brûlures ou que leurs vêtements
ne s’enflamment.
DO NOT ATTEMPT TO ALTER OR MODIFY
THE CONSTRUCTION OF THE APPLIANCE OR
ITS COMPONENTS. ANY MODIFICATION OR
ALTERATION MAY VOID THE WARRANTY, CERTIFICATION AND LISTINGS OF THIS UNIT.
Innovative Hearth Products
SuperiorTM DRT35 See Through and Peninsula Direct Vent Gas Fireplace
Installation and Operation Instructions
900300-00, 02/2015
WARNING
Improper installation, adjustment, alteration, service or
maintenance can cause injury
or property damage. Refer to
this manual. For assistance or
additional information consult
a qualified installer, service
agency or the gas supplier.
WARNING
Failure to comply with these
installation instructions will result
in an improperly installed and
operating appliance, voiding its
warranty. Any change to this appliance and/or its operating controls
is dangerous.
WARNING
Clothing or other flammable
material should not be placed
on or near the appliance.
AVERTISSEMENT
On ne devrait pas placer de
vêtements ni d’autres matières
inflammables sur l’appareil ni à
proximité.
WARNING
Any safety screen or guard
removed for servicing the appliance must be replaced prior to
operating the appliance.
AVERTISSEMENT
Tout écran ou protecteur retiré
pour permettre l’entretien de
l’appareil doit être remis en
place avant de mettre l’appareil
en marche.
NOTE: If the barrier becomes dam-
aged, the barrier shall be replaced with the manufacturer’s
barrier for this appliance.
Note: Installation and repair should be done
by a qualified service person. The appliance
should be inspected before use and at least
annually by a professional service person.
More frequent cleaning may be required
due to excessive lint from carpeting, bedding material, etcetera. It is imperative
that control compartments, burners and
circulating air passageways of the appliance
be kept clean.
Remarque: L’installation et la réparation
devrait être confiées à un technicien qualifié.
L’appareil devrait faire l’objet d’une inspection
par un technicien professionnel avant d’être
utilisé et au moins une fois l’an par la suite.
Des nettoyages plus fréquents peuvent être
nécessaires si les tapis, la literie, et cetera
produisent une quantité importante de poussière. Il est essentiel que les compartiments
abritant les commandes, les brûleurs et les
conduits de circulation d’air de l’appareil
soient tenus propres.
Do not use these appliances if any part
has been under water. Immediately call a
qualified, professional service technician
to inspect the appliance and to replace any
parts of the control system and any gas
control which have been under water.
Ne pas utiliser cet appareil s’il a été plongé,
même partiellement, dans l’eau. Appeler un technicien qualifié pour inspecter
l’appareil et remplacer toute partie du
système de commande et toute commande
qui a été plongée dans l’eau.
IMPROPER INSTALLATION OR USE OF THIS
APPLIANCE CAN CAUSE SERIOUS INJURY OR
DEATH FROM FIRE, BURNS, EXPLOSION OR
CARBON MONOXIDE POISONING.
Only trim kit(s) supplied by the manufacturer
shall be used in the installation of this appliance.
Seules les trousses de garniture fournies
par le fabricant doivent être utilisées pour
l’installation de cet appareil.
These appliances comply with National Safety
Standards and are tested and listed by PFS
(Report No. F14-165) to ANSI Z21.88 (in Canada,
CSA-2.33), and CAN/CGA-2.17-M91, latest editions, in both USA and Canada, as vented gas
fireplace heaters
Both millivolt and electronic versions of these
appliances are listed by PFS Corporation for
installation in bedrooms and Manufactured
Homes.
Misc. Codes / Standards -
The Installation must conform to local codes or,
in the absence of local codes, with the National
Fuel Gas Code, ANSI Z223.1/NFPA 54 - latest
edition (In Canada, the current CAN/CSA-B149.1
installation code).
The appliance, when installed, must be electrically grounded and wired in accordance with
local codes or, in the absence of local codes,
with the National Electrical Code, ANSI/NFPA
70 - latest edition, or the Canadian Electrical
Code, CSA C22.1 - latest edition.
Provide adequate clearances around air openings and adequate accessibility clearance for
service and proper operation. Never obstruct the
front or back openings of the appliance.
These appliances are designed to operate on
natural or propane gas only. The use of other
fuels or combination of fuels will degrade
the performance of this system and may be
dangerous.
These fireplaces are designed as supplemental
heaters. Therefore, it is advisable to have an
alternate primary heat source when installed
in a dwelling.
Millivolt Models - The millivolt appliances are
manually controlled and feature a spark igniter
(piezo) that allows the appliance's pilot gas to
be lit without the use of matches or batteries.
This system provides continued service in the
event of a power outage.
Millivolt models come standard with a manually-modulated gas valve; flame appearance and
heat output can be controlled at the gas valve.
The BTU Input for these appliances is shown
in Table 1.
Electronic Models - Electronic models have a
fixed rate gas valve. Input of electronic models
is shown in Table 1.
Input (BTU) Gas Valves (all models)
ModelsFuel
35" ST/PF DMN
(Millivolt)
35" ST/PF DMP
(Millivolt)
35" ST/PF DEN
(Electronic)
35" ST/PF
(Electronic)
(if field converted)
Type
Natural
Propane
Natural30,000
Propane28,000
Input Rate
(BTU / HR)
30,000 high
23,000 low
28,000 high
22,000 low
Table 1
Efficiencies %
Natural GasPropane
ModelsAFUEP4AFUEP4
STDMN-P
STDEN
PFDMN-P
PFDEN
68.859.0370.358.66
74.854.73n/an/a
69.260.169.758.66
74.854.73n/an/a
5
Innovative Hearth Products
SuperiorTM DRT35 See Through and Peninsula Direct Vent Gas Fireplace
Installation and Operation Instructions
900300-00, 02/2015
Gas Pressure - All Models
Tables 2 and 3 show the appliances' inlet and
manifold gas pressure requirements:
Inlet Gas Supply Pressure
(all models)
Fuel #MinimumMaximum
Natural Gas
Propane
4.5" WC
(1.12 kPa)
11.0" WC
(2.74 kPa)
10.5" WC
(2.61 kPa)
13.0" WC
(3.23 kPa)
Table 2
Manifold Gas Supply Pressure
(all models)
Fuel #LowHigh
Natural
Gas
Propane
(Lo) 2.2" WC
(0.55 kPa)
(Lo) 6.3" WC
(1.57 kPa)
(Hi) 3.5" WC
(0.87 kPa)
(Hi) 10.0" WC
(2.49 kPa)
Table 3
Test gauge connections are provided on the
front of the millivolt and electronic gas control
valve (identified IN for the inlet and OUT for the
manifold side). The control valves have a 3/8"
(10mm) NPT thread inlet and outlet side of the
valve (refer to Figures 1 and 2).
Propane tanks are at pressures that will cause
damage to valve components. Verify that the
tanks have step down regulators to reduce the
pressure to safe levels.
These appliances must be isolated from the
gas supply piping system (by closing their
individual manual shut-off valve) during any
pressure testing of the gas supply piping
system at test pressures equal to or less than 1/2 psig (3.5 kPa).
These appliances and their individual shut-off
valves must be disconnected from the gas
supply piping system during any pressure
testing of that system at pressures greater than 1/2 psig (3.5 kPa).
These appliances must not be connected to a
chimney or flue serving a separate solid fuel
burning appliance.
Orifice Sizes - Sea Level to High Altitude
(All Models)
These appliances are tested and approved for
installation at elevations of 0-4500 feet (0-1372
meters) above sea level using the standard burner
orifice sizes (marked with an "*" in Table 4 ).
For elevations above 4500 feet, contact your gas
supplier or qualified service technician.
Deration - At higher elevations, the amount of
BTU fuel value delivered must be reduced by
either using gas that has been derated by the gas
company or by changing the burner orifice to a
smaller size as regulated by the local authorities
having jurisdiction and by the (USA) National
Fuel Gas Code NFPA 54/ANSI Z223.1 - latest
edition or, in Canada, the CAN/CSA-B149.1
codes - latest edition.
Install the appliance according to the regulations
of the local authorities having jurisdiction and,
in the USA, the National Fuel Gas Code NFPA
54 / ANSI Z223.1 - latest edition or, in Canada,
the CAN/CSA-B149.1 - latest edition.
Flame breadth, height and width will dimenish
4% for every 1,000 feet of altitude.
Burner Orifice Sizes (all models)
Elevation
Feet (meters)
0-4500
(0-1372)
Table 4
• Part /Cat. Number
Natural
Gas
drill size (inches)
#37 (0.104")
24M10 •
* Standard size installed at factory
drill size (inches)
1.55
*
Propane
Gas
mm
(0.061")
42M79 •
*
Gas Valve Diagrams
See Figure 1 for Millivolt models and Figure 2
For Electronic Models.
Main Gas Control Knob
OFF/PILOT/ON
N
O
T
O
it
L
I
P
O
F
F
OUT
IN
Manifold Pressure Tap
Inlet Pressure Tap
Pilot Adjustment
L
I
P
W
O
L
H
I
HI/LO Variable
Flame Height
Adjustment
Screw
T
O
HTPTHTPT
Figure 1 - SIT Millivolt Gas Valve
OFF
ON
ON/OFF Switch
IN
PSI
Inlet
Pressure
Port
Electronic
Gas Control
Valve
Manifold Pressure Port
CONTROL
IGNITER
Honeywell Electronic
Figure 2
COMMONWEALTH OF MASSACHUSETTS
REQUIREMENTS
These appliances are approved for installation in
the US state of Massachusetts if the following
additional requirements are met:
• Install this appliance in accordance with
Massachusetts Rules and Regulations 248
C.M.R. Sections 4.00 through 8.00.
• Installation and repair must be done by a
plumber or gas fitter licensed in the Commonwealth of Massachusetts.
• The flexible gas line connector used shall
not exceed 36 inches (92 centimeters) in
length.
• The individual manual shut-off must be a
T-handle type valve.
Massachusetts Horizontal Vent Requirements
In the Commonwealth of Massachusetts, horizontal terminations installed less than seven
(7) feet above the finished grade must comply
with the following additional requirements:
• A hard wired carbon monoxide detector
with an alarm and battery back-up must be
installed on the floor level where the gas
fireplace is installed. The carbon monoxide
detector must comply with NFPA 720, be
ANSI/UL 2034 listed and be ISA certified..
• A metal or plastic identification plate must
be permanently mounted to the exterior of
the building at a minimum height of eight (8)
feet above grade and be directly in line with
the horizontal termination. The sign must
read, in print size no less than one-half (1/2)
inch in size, GAS VENT DIRECTLY BELOW.
KEEP CLEAR OF ALL OBSTRUCTIONS.
Gas Valve
NEW YORK CITY, NEW YORK (MEA)
Installation of these fireplaces are approved
for installation in New York City in the US state
of New York.
6
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Innovative Hearth Products
SuperiorTM DRT35 See Through and Peninsula Direct Vent Gas Fireplace
COLD CLIMATE INSULATION
For cold climate installations, seal all cracks
around your appliance with noncombustible
material and wherever cold air could enter
the room. It is especially important to insulate
outside chase cavity between studs and under
floor on which appliance rests, if floor is above
ground level. Gas line holes and other openings should be caulked or stuffed with unfaced
fiberglass insulation.
If the fireplace is being installed on a cement
slab in cold climates, a sheet of plywood or
other raised platform can be placed underneath
to prevent conduction of cold transferring to
the fireplace and into the room. It also helps to
sheetrock inside surfaces and tape for maximum
air tightness and caulk firestops.
MANUFACTURED HOME
REQUIREMENTS
This appliance may be installed in an aftermarket permanently located, manufactured home
and must be installed in accordance with the
manufacturer's instructions and the Manufactured Home Construction and Safety Standard,
Title 24 CFR, Part 3280, in the United States, or
the Standard for Installation in Mobile Homes,
CAN/CSA Z240 MH Series, in Canada.
Cet appareil peut être installé cómme du matériel d'origine dans une maison préfabriquée (É.U.
seulement) ou mobile et doit être installé selon
les instructions du fabricant et conformément
à la norme Manufactured Home Constructions
and Safety, Title 24 CFR, Part 3200 aux Unis ou
à la norme Can/CSA-Z240 Série MM, Maisons
mobiles au Canada.
(See-Through Model Shown)
Horizontal Vent
(top vent)
Vertical
Vent
Installation and Operation Instructions
900300-00, 02/2015
Vertical
Venting
Offset Venting
(one end flush
with wall)
When the unit is installed with one side flush with a
wall, the wall on the other side of the unit must not
extend beyond the front edge of the unit.
Horizontal Vent
(side vent)
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is
not convertible for use with other gases, unless
a certified kit is used.
Cet appareil doit être utilisé uniquement avec le
type de gaz indiqué sur la plaque signalétique.
Cet appareil ne peut être converti à d'autres gaz,
sauf si une trousse de conversion est utilisée.
CAUTION: Ensure that the cross members are not cut or weakened during
installation. The structural integrity of
the manufactured home floor, wall, and
ceiling / roof must be maintained.
CAUTION: This appliance must be grounded to the chassis of the manufactured
home in accordance with local codes or
in the absence of local codes, with the
National Electrical Code ANSI / NFPA 70
- latest edition or the Canadian Electrical
Code CSA C22.1 - latest edition.
Figure 3
LOCATION
In selecting the location, the aesthetic and functional use of the appliance are primary concerns.
However, vent system routing to the exterior and access to the fuel supply are also important.
Due to high temperatures, the appliance should be located out of traffic and away from furniture
and draperies (Figure 3).
En raison des températures élevées, l’appareil devrait être installé dans un endroit où il y a
peu de circulation et loin du mobilier et des tentures (Figure 3).
The location should also be free of electrical, plumbing or other heating/air conditioning ducting.
These direct-vent appliances are uniquely suited for installations requiring a utility shelf positioned
directly above the fireplace. Utility shelves like these are commonly used for locat-ing television
sets and decorative plants.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
7
Innovative Hearth Products
12
X
Roof Pitch is X/12
2 FT
MIN.
2 FT MIN.
Lowest
Discharge
Opening
H*
*H = MINIMUM HEIGHT FROM ROOF TO
LOWEST DISCHARGE OPENING OF VENT
TERMINATION HEIGHTS FOR VENTS ABOVE
FLAT OR SLOPED ROOFS
Horizontal Overhang
Vertical
Wall
Vent
Termination
Storm Collar
Concentric
Vent Pipe
Flashing
1 inch (25.4 mm) Minimum
Clearance to Combustibles
SuperiorTM DRT35 See Through and Peninsula Direct Vent Gas Fireplace
Installation and Operation Instructions
900300-00, 02/2015
Be aware that this is a heat producing appliance. Objects placed above the unit are
exposed to elevated temperatures.
Do not insulate the space between the appliance and the area above it (see Figure 8 ).
The minimum height from the base of the appliance to the underside of combustible materials
used to construct a utility shelf in this fashion
is shown in Figure 8.
The appliance should be mounted on a fully
supported base extending the full width and
depth of the unit. The appliance may be located
on or near conventional construction materials.
However, if installed on combustible materials,
such as carpeting, vinyl tile, etc., a metal or
wood barrier covering the entire bottom surface
must be used.
VENT TERMINATION CLEARANCES
These instructions should be used as a
guideline and do not supersede local codes
in any way. Install venting according to local
codes, these instructions, the current National
Fuel Gas Code (ANSI-Z223.1) in the USA or
the current standards of CAN/CSA-B149.1
in Canada.
Flat to 6/121.00.3
6/12 to 7/121.250.38
7/12 to 8/121.50.46
8/12 to 9/122.00.61
9/12 to 10/122.50.76
10/12 to 11/123.250.99
11/12 to 12/124.01.22
12/12 to 14/125.01.52
14/12 to 16/126.01.83
The vent / air intake termination clearances
above the high side of an angled roof is as
shown in the following chart:
16/12 to 18/127.02.13
18/12 to 20/127.52.29
20/12 to 21/128.02.44
Figure 5
Horizontal Vent Termination Clearances
The horizontal vent termination must have a minimum of 6" (152 mm) clearance to any overhead
combustible projection of 2-1/2" (64 mm) or less (see Figure 6). For projections exceeding 2-1/2"
(64 mm), see Figure 6. For additional vent location restrictions refer to Page 9.
Vertical Vent Termination Clearances
Terminate multiple vent terminations according to
the installation codes listed above and Figures
4 and 5.
Figure 4 - Multiple Terminations
8
12”
(305mm)
Minimum
Horizontal Vent Termination Clearances
Combustible Projection
inches or less in length
2-1/2
Combustible Projection greater
than 2-1/2 inches in length
Ventilated
Soffit
Unventilated
Soffit
6"
18"
(457 mm)
12"
(305 mm)
(152 mm)
Side Elevation View
Termination Kit
Figure 6
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
All horizontal terminations
may be located as close as
6” (152mm) to any
(non-combustible and
combustible) exterior
sidewall. This distance
may be decreased to 2”
(51mm) for non-combustible exterior
sidewalls only, if the
SV4.5HT-2 termination
is used.
Termination Kit
Note - See Figure 36 on Page 21 for the exterior wall recess
allowances of the square horizontal termination.
Innovative Hearth Products
(TERMINATION PROHIBITED)
Inside Corner
Outside CornerRecessed Location
Balcony with No Side
SuperiorTM DRT35 See Through and Peninsula Direct Vent Gas Fireplace
Clearance to window or door that may be opened6” (150mm)
B
Clearance to permanently closed window9” (229mm)
C
Vertical clearance to ventilated sot located above the
D
termination within a horizontal distance of 18” (458mm)
Clearance to unventilated sot12” (305mm) 12” (305mm)
E
C
F
V
B
TERMINATION CAP
V
Fixed
Closed
Openable
V
Openable
V
B
A
AIR SUPPLY INLET
X
Fixed
Closed
J
B
V
B
X
G
GAS METERRESTRICTED AREA
See Figure 5
H
G
V
V
F
I
G
G
M
V
K
V
G
V
X
A
U.S. Installation **Canadian Installation *
for replaces <10,000Btu/h (3kW),
9” (230mm)
for replaces >10,000Btu/h (3kW), and <50,000Btu/h
(15kW),
12” (300mm)
for replaces >50,000Btu/h (15kW)**
recommended to prevent windowcondensation
18” (458mm)18” (458mm)
WallVBalcony with Perpendicular Side Wall
M
M
V
6” (150mm)
for replaces <10,000Btu/h (3kW),
12” (300mm)
for replaces >10,000Btu/h (3kW)
12” (305mm)
recommended to prevent
windowcondensation
Installation and Operation Instructions
900300-00, 02/2015
P
N
Q
V
O
Clearance to outside corner5” (127mm)
F
Clearance to inside corner6” (152mm) minimum6” (152mm) minimum
G
Clearance to each inside of center line extended above
H
meter / regulator assembly
Clearance to service regulator vent outlet36” (910mm)**36” (910mm)*
I
Clearance to nonmechanical air supply inlet to building or
J
the combustion air inlet to any other replace
Clearance to a mechanical air supply inlet36” (910mm) above if within 10 (3m) horizontally**72” (1830mm)*
K
Clearance above paved sidewalk or paved diveway located
L
on public property
Clearance under veranda, porch, deck or balcony12” (300mm)*‡12” (300mm)*‡
M
Depth of alcove (maximum)72” (1830mm)**72” (1830mm)*
N
Clearance to termination (alcove)6” (15.2mm)**6” (15.2mm)*
O
Width of alcove (minimum)36” (910mm)**36” (910mm)*
P
Clearance to combustible above (alcove)18” (457mm)**18” (457mm)*
Q
*
In accordance with the current CSA-B149.1 National Gas And Propane Installation Code
**
In accordance with the curent ANSI Z223.1/NFPA 54 National Fuel Gas Codes
‡
A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings
*‡
Only permitted if veranda, porch, deck, or balcony is fully-open on a minimum two sides beneath the oor
minimum
36” (910mm)
within a height of 15 above the meter / regulator assembly**
6” (150mm)
for replaces <10,000Btu/h (3kW),
9” (230mm)
for replaces >10,000Btu/h (3kW) and <50,000Btu/h
(15kW),
12” (300mm)
for replaces >50,000Btu/h (15kW)**
84” (2130mm)‡84” (2130mm)‡
5” (127mm)
minimum
36” (910mm)
within a height of 15 above the meter /
regulator assembly*
6” (150mm)
for replaces <10,000Btu/h (3kW),
12” (300mm)
for replaces >10,000Btu/h (3kW)
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
9
Innovative Hearth Products
15 (381
19 (483
17 (432
SuperiorTM DRT35 See Through and Peninsula Direct Vent Gas Fireplace
Installation and Operation Instructions
900300-00, 02/2015
MINIMUM CLEARANCES TO COMBUSTIBLES
Appliance And Vent Clearances
The appliance is approved with zero clearance to combustible materials on all sides (as detailed
in Table 5), with the following exception: When the unit is installed with one side flush with a wall, the wall on the other side of the unit must not extend beyond the front edge of the unit.
In addition, when the unit is recessed, the side walls surrounding the unit must not extend beyond
the front edge of the unit (see Figure 3).
*Note: 3 in. (75 mm) above any horizontal/inclined vent component.
**Note: See Page 12, Step 1 for clearance requirements to the nailing flange located at each side
of the unit and any screw heads adjacent to it.
Mantel Depth
13 (330)
11 (279)
9 (289)
)
)
)
5" Standoff
inches (millimeters)
Top of
Appliance
Hearth Extension - A hearth extension is not
required with this appliance. If a hearth extension is used, do not block the lower control
compartment door. Any hearth extension used
is for appearance only and does not have to
conform to standard hearth extension installation requirements.
Shelf Height - To provide for the lowest pos-
sible shelf surface, use the alternate rear vent
outlet, the venting attached to the top vent should
be routed in a way to minimize obstructions to
the space above the appliance. Do not insulate
the space between the appliance and the area
above it (see Figure 8). The minimum height
from the base of the appliance to the underside of
combustible materials used to construct a utility
shelf in this fashion is shown in Figure 8.
The appliance should be mounted on a fully
supported base extending the full width and
depth of the unit. The appliance may be located
on or near conventional construction materials.
However, if installed on combustible materials,
such as carpeting, vinyl tile, etc., a metal or
wood barrier covering the entire bottom surface
must be used.
12
(305)
8
10
(203)
(254)
Front or Rear Face
of Appliance
(152)
6
(102)
2
4
(51)
Figure 7 - Minimum Mantel Clearances
Do not insulate this space
Do not insulate this space
above the appliance.
Shelf Height
(see table)
Shelf Above Fireplace With Side Venting
Shelf Height - Inches (millimeter)
Model No.
Side Vent - Straight Out BackTop Vent - with One 90 Degree Elbow
Secure Vent & Secure FlexSecure VentSecure Flex
ST/PF37-3/16 (945)*49-1/2 (1245)*51-1/4 (1302)
* Includes 3” clearance to combustibles (required above vent components)
above the appliance.
Shelf Height
(see table)
Shelf Above Fireplace With Top Venting
Wall Finishes / Surrounds / Mantels
Note: Combustible wall finish materials and/
or surround materials must not be allowed to
encroach the area defined by the appliance front
face (black sheet metal). Never allow combus-
tible materials to be positioned in front of or
overlapping the appliance face (see Figure 65
on Page 37).
Non-combustible materials, such as surrounds
and other appliance trim, may be installed on
the appliance face with these exceptions: they
must not cover any portion of the removable
glass panel or control compartment.
Vertical installation clearances to combustible
mantels vary according to the depth of the
mantel. See Figure 9. Mantels constructed of
non-combustible materials may be installed
at any height above the appliance opening;
however, do not allow anything to hang below
the fireplace hood.
10
Figure 8 -
Shelf Height Minimum Clearances
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Innovative Hearth Products
(25)
(51)
(76)
(102)
(127)
SuperiorTM DRT35 See Through and Peninsula Direct Vent Gas Fireplace
Installation and Operation Instructions
900300-00, 02/2015
MINIMUM CLEARANCES* Inches (millimeters)
Sides1/2 in. (13)
0 (0) from Spacers Or Dimples **
Top of Appliance5 (127)
Floor0 (0)
From Bottom of Unit To Ceiling72 (1829)
Vent3 (76) Top * / 1 (25.4) Sides & Bottom
SERVICE CLEARANCES Feet (meters)
Front, Back, Sides3 feet (0.9 meters)
Table 5
Combustible Materials
Allowed In Shaded Area
“Safe Zone”
Inches (millimeters)
Top View of
At 5" minimum side
wall clearance, the wall
(shown in dark gray) can
be any length.
Figure 9
o
45
1
3
4
5
2
Fireplace
Minimum
1 (25)
Distance to
2 (51)
Unprotected
3 (76)
Side Wall
4 (102)
5 (127)
6 (152)
7 (178)
8 (203)
9 (229)
10 (250)
One end of the unit may be
flush with a perpendicular
wall, but the wall at the other
end must not extend beyond
the front edge of the unit.
WARNING
Failure to position the parts in accordance with these
diagrams or failure to use only parts specifically
approved with this appliance may result in property
damage or personal injury.
AVERTISSEMENT
Risque de dommages ou de blessures si les pièces
ne sont pas installées conformément à ces schémas
et ou si des pièces autres que celles spécifiquement
approuvées avec cet appareil sont utilisées.
DETAILED INSTALLATION STEPS
The appliance is shipped with all gas controls and components installed
and pre-wired.
1. Remove the shipping pad, exposing the front face assembly with barrier
and hood. Remove the hood by pulling firmly straight away from the unit.
2. Remove the face assembly with barrier by lifting the front face assembly approximately 1/2" then pull straight out away from the fireplace
until the mounting tabs clear, exposing the glass door.
3. Open the two latches (located under the firebox floor) securing the
glass door. Remove the door by tilting it outward at the bottom and
lifting it up. Set the door aside protecting it from inadvertent damage.
See Removing and Installing Glass Panels on Page 35.
4. Lift the pressure relief plates and remove the cardboard from beneath
each plate (be careful not to damage the white gasket).
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
11
Innovative Hearth Products
SuperiorTM DRT35 See Through and Peninsula Direct Vent Gas Fireplace
Installation and Operation Instructions
900300-00, 02/2015
Pressure Relief
Plates
REMOVE
CARDBOARD
BEFORE USING
Remove Cardboard Before
Using Appliance
REMOVE
CARDBOARD
BEFORE USING
Figure 11
TYPICAL INSTALLATION SEQUENCE
The typical sequence of installation is outlined
below. However, each installation is unique
and may result in variations to the steps
described.
See the page numbers references in the following steps for detailed procedures.
Step 1. (Page 12) Construct the appliance
framing. Position the appliance within the
framing and secure with nailing brackets. Bend
up the appropriate header spacing guides for
the drywall/finish material thickness to be used
(refer to Figure 62, page 35). Bend up the
outer pair for 1/2" materials and the inner pair
for 5/8" materials. Bend out the appropriate
nailing flanges for the drywall/finish material
to be used. Nailing flanges are provided for
flush framing, 1/2 inch and 5/8 inch framing
depths (see Figure 12).
Step 2. (Page 15) Route gas supply line to
appliance location.
Step 4. (Page 16) Install the vent system and
exterior termination.
Step 5. (Page 28) Field Wiring
a. Millivolt Appliances –Install the operating
control switch (not factory provided) and bring
in electrical service line for forced air-circulating
blower (optional equipment).
b. Electronic Appliances – Field wire and install
operating control switch.
Step 12. (Page 37) Install front face assembly
with barrier. Install the hoods.
Step 13. (Page 38) Attach Safety in Operation
Warnings.
Before proceeding it may be helpful to remove
the log set form the firebox and remove the
embers and volcanic stone from the control
compartment. Refer to the following steps:
1. Remove the front face assembly, hood
and glass enclosure panel (see Removing and Installing Glass Enclosure Panels on Page 35).
Step 1. FRAMING
Frame these appliances as illustrated in Figures
13 and 14 on Pages 13 and 14. All framing
details must allow for a minimum clearance
to combustible framing members as shown
in Table 5 on Page 8.
If the appliance is to be elevated above floor level,
a solid continuous platform must be constructed
below the appliance.
Headers may be in direct contact with the appliance top spacers when they are bent up vertically
maintaining the 3" clearance to the fireplace top,
but must not be supported by them or notched
to fit around them. All construction above the
appliance must be self-supporting. DO NOT use
the appliance for structural support.
The fireplace should be secured to the side
framing members using the unit's nailing
flanges - one top and bottom on each side of
the fireplace front. See Figure 12. Use 8d nails
or their equivalent.
Step 3. Preparing the appliance vent collar
(Page 15).
12
2. Remove log set box from firebox. Next,
remove embers and volcanic stone from control compartment. Handle logs carefully to
prevent breakage.
Unit Being Secured by Its Nailing
Flanges to the Framing
Figure 12 - Nailing Flanges
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Innovative Hearth Products
**20-3/4
SuperiorTM DRT35 See Through and Peninsula Direct Vent Gas Fireplace
SPECIFICATIONS
Natural Gas BTU Input30,000
Propane Gas BTU Input28,000
Co-axial DV Vent Size
4-1/2" Inner /
7-1/2" Outer
NOTES
All specifications, ratings and dimensions are
subject to change without notice.
Appliance has a factory-installed vent seal cap
(see Figures 16 & 17 on Page 16) in each flue
outlet.
***This dimension does
not include the addition
of drywall to the inside of
framing or clearance for
the Side Vent Seal Cap.
Adjust accordingly for your
installation.
See also, Side Vent Seal Cap
note below.
***39-7/8
37-3/16
(945)
(1013)
Vent Center - Top Vent
with one 90 degree
elbow
Center of gas line
is 3-1/8 inches
(79 mm) up from
floor.
5-5/8
(143)
12-1/8
(308)
5-1/8
(130)
Vent Center - Side Vent
with no elbows
12-1/8
(308)
Installation and Operation Instructions
900300-00, 02/2015
(527)
10-1/2
(267)
**This dimension
based on 5/8" drywall.
For 1/2" drywall use
21" (533 mm). The
finished dimension
should be 22" (558
mm)
Secure Vent
42-3/4 (1086)
Secure Flex
43-1/2 (1105)
5-1/8
(130)
25-1/2
(648)
Control Switch Wires
Knock-Out
Gas
Inlet
Framing Spacers
(top and both sides)
11 (279)
37-1/16
(941)
1-1/4
(44)
18-1/4
(464)
Top View
Optional
Blower
Vent Seal Cap
41-13/16 (1062)
40-1/4 (1022)
35-1/4 (895)
10-7/8 (264)
11 (279)
5/8
(16)
4-15/16
(125)
Provide
additional
space for
Side Vent
Seal Cap if
installing
against
a solid
wall.
25-1/2
(648)
Vertical Venting Through the Ceiling:
Frame ceiling opening - Use a plumb line
from the ceiling above the appliance to
locate center of the vertical run. Cut and/or
frame an opening, 10-1/2" x 10-1/2" (267
mm x 267 mm) inside dimensions, about
this center mark (see Figure 20).
11 (279)
Control Switch Wires
Knock-Out
Gas
Inlet
25-1/2
(648)
3-1/8 (79)
Left Side View
Figure 13
6-1/4
(159)
Junction Box Knock-Out
(2 places each side)
29 (737)
32-5/8 (829)
Control Compartment
Front face view (two sides)
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Door
3-1/8 (79)
6-1/4
(159)
Junction Box Knock-Out
(2 places each side)
Right Side View
13
Innovative Hearth Products
**20-3/4
SuperiorTM DRT35 See Through and Peninsula Direct Vent Gas Fireplace
Installation and Operation Instructions
900300-00, 02/2015
SPECIFICATIONS
Natural Gas BTU Input30,000
Propane Gas BTU Input28,000
Co-axial DV Vent Size
4-1/2" Inner /
7-1/2" Outer
NOTES
All specifications, ratings and dimensions are
subject to change without notice.
Appliance has a factory-installed vent seal cap
(see Figures 16 & 17 on Page 16) in each flue
outlet.
Fireplace Framing Specifications
***This dimension does
not include the addition
of drywall to the inside of
framing or clearance for
the Side Vent Seal Cap.
Adjust accordingly for your
installation.
See also, Side Vent Seal Cap
note below.
37-3/16
(945)
***38-3/4
(984)
Notes:
Vent Center - Top Vent
with one 90 degree
elbow
Vent Center - Side Vent
with no elbows
Center of gas line
is 3-1/8 inches
(79 mm) up from
floor.
5-5/8
(143)
• Inches (millimeters)
•
Minimum Framing Stud Size is 2 x 4
• See
side views of fireplace below
gas line inlet location options.
(527)
10-1/2
(267)
12-1/8
(308)
5-1/8
(130)
12-1/8
(308)
for
**This dimension
based on 5/8" drywall.
For 1/2" drywall use
21" (533 mm). The
finished dimension
should be 22" (558
mm)
Secure Vent
42-3/4 (1086)
Secure Flex
43-1/2 (1105)
5-1/8
(130)
25-1/2
(648)
37-1/16
(941)
Figure 14
18-1/4
(465)
25-5/16 (643)
22 (559)
15-3/4 (400)
19-11/16 (500)
Left Side View
Framing Spacers
(top and both sides)
1-1/4
(44)
37-1/16
(941)
29-3/16
(741)
18-1/4
(464)
Top View
Optional
Blower
Vent Seal Cap
41-13/16 (1062)
40-1/4 (1022)
35-1/4 (895)
32-5/8 (829)
29 (737)
Front View
10-7/8 (264)
11 (279)
5/8
(16)
4-15/16
(125)
Provide
additional
space for
Side Vent
Seal Cap if
installing
against
a solid
wall.
25-1/2
(648)
3-1/8 (79)
Control Compartment
Door
Vertical Venting Through the Ceiling:
Frame ceiling opening - Use a plumb line
from the ceiling above the appliance to
locate center of the vertical run. Cut and/or
frame an opening, 10-1/2" x 10-1/2" (267
mm x 267 mm) inside dimensions, about
this center mark (see Figure 20).
11 (279)
Control Switch Wires
Knock-Out
Gas
Inlet
25-1/2
(648)
6-1/4
(159)
Junction Box Knock-Out
(2 places each side)
14
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Innovative Hearth Products
SuperiorTM DRT35 See Through and Peninsula Direct Vent Gas Fireplace
Installation and Operation Instructions
900300-00, 02/2015
Step 2. ROUTING GAS LINE
Route a 1/2" (13 mm) gas line to the left side
of the appliance as shown in Figure 15. Gas
lines must be routed, constructed and made
of materials that are in strict accordance with
local codes and regulations. All appliances
are factory-equipped with a flexible gas line
connector and 1/2 inch shutoff valve. (See
Step 6 on Page 29).
3-1/8"
(79 mm)
5-5/8"
(143 mm)
Also see Figures 13 and 14.
Figure 15 - Route Gas Line
Proper Sizing of Gas Line
Properly size and route the gas supply line
from the supply regulator to the area where the
appliance is to be installed per requirements
outlined in the National Fuel Gas Code, NFPA
54 - latest edition (USA) or CAN/CSA-B149.1
- latest edition (Canada).
Never use galvanized or plastic pipe. Refer to
Table 6 for proper sizing of the gas supply line,
if black iron pipe is being used. Gas lines must
be routed, constructed and made of materials
that are in strict accordance with local codes
and regulations. We recommend that a qualified
individual such as a plumber or gas fitter be
hired to correctly size and route the gas supply
line to the appliance.
Schedule 40
Black Iron Pipe
Inside Diameter (Inches)
Schedule 40 Pipe
Length (feet)
0-101/23/8
10-401/21/2
40-1001/21/2
100-1503/41/2
150-2003/41/2
Natural
Gas
Propane
Gas
Table 6
Notes:
• All appliances are factory-equipped with
a flexible gas line connector and 1/2 inch
shutoff valve (see Figure 50 on Page 31).
• See Massachusetts Requirements on Page 4 for additional requirements for installations
in the state of Massachusetts in the USA.
• The gas supply line should Not be connected
to the appliance until Step 6 (Page 29).
• A pipe joint compound rated for gas should be
used on the threaded joints. Ensure propane
resistant compounds are used in propane
applications. Be very careful that the pipe
compound does not get inside the pipe.
• It is recommended to install a sediment
trap in the supply line as close as possible
to the appliance. Appliances using Propane
should have a sediment trap at the base of
the tank.
• Check with local building official for local
code requirements (i.e. are below grade
penetrations of the gas line allowed?, etc).
IMPORTANT: If propane is used, be aware that
if tank size is too small (i.e. under 100-lbs, if
this is the only gas appliance in the dwelling.
Ref. NPFA 58), there may be loss of pressure,
resulting in insufficient fuel delivery (which
can result in sooting, severe delayed ignition
or other malfunctions). Any damage resulting
from an improper installation, such as this, is
not covered under the limited warranty.
Step 3. PREPARING THE APPLIANCE
VENT COLLAR
WARNING
Failure to reinstall and securely
tighten vent seal cap screws
could result in leakage of flue
products into the living space.
Vent seal cap must remain
securely installed on unused
vent collar. Failure to do so
could result in leakage of flue
products into living space.
REMOVE VENT SEAL CAP
(From the vent that will be used only)
Top Vent Installations - See Figure 16
Side Vent Installations - See Figure 17
Preparing the Appliance Vent Collar
Each of the appliances' two vent collars are
sealed with a seal cap which must be removed
from the vent collar being used. In top vent
installation the cover plate shall be removed
from the inside. Refer to Figure 16 for top
vent installations and Figure 17 for side vent
installations and the following steps to prepare
the appropriate collar for use.
From the vent collar being used, remove the
two screws securing the vent seal cap. Twist
the cap counterclockwise. Pull it away from
the appliance and discard, along with the piece
of insulation.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
15
Innovative Hearth Products
SuperiorTM DRT35 See Through and Peninsula Direct Vent Gas Fireplace
Installation and Operation Instructions
900300-00, 02/2015
CROSS SECTION
(OUTSIDE of
Appli
ance)
Insulation
Cabinet Top
Figure 16 -
(INSIDE of
Appli
ance)
Side Vent
Cabinet Back
Securing Screws
Firebox Top
Top Vent
Cover Plate
(INSIDE of Appli
TOP VENT SEAL CAP REMOVAL
(TOP VENT INSTALLATIONS ONLY)
Insulation
CROSS SECTION
ance)
Vent Seal Cap
(OUTSIDE of
Vent Seal Cap
Appli
ance)
Securing Screws
Step 4. INSTALL THE VENT SYSTEM
General Information
These instructions should be used as a guideline and do not supersede
local codes in any way. Install venting according to local codes, these
instructions, the current National Fuel Gas Code (ANSI-Z223.1) in the
USA or the current standards of CAN/CSA-B149.1 in Canada.
Ensure clearances are in accordance with local installation codes and
the requirements of the gas supplier.
Dégagement conforme aux codes d'installation locaux et aux exigences
du foumisseunde gaz.
Use only approved venting components. See Approved Vent Components on Page 4.
These fireplaces must be vented directly to the outside.
The vent system may not service multiple appliances, and must never
be connected to a flue serving a solid fuel burning appliance. The vent
pipe is tested to be run inside an enclosed wall (such as a chase). There
is no requirement for inspection openings in the enclosing wall at any of
the joints in the vent pipe.
Installation of Vent Restrictor
A vent restrictor may be needed with this appliance. The restrictor is
installed in the appliance top flue outlet as shown in Figure 16, either
before adding vent, from above, or after installation of vent from below,
within the firebox. The restrictor is self securing through a positive
friction fit.
Figure 17 -
(SIDE VENT INSTALLATIONS ONLY)
VENT RESTRICTOR INSTALLATION
SIDE VENT SEAL CAP REMOVAL
A vent restrictor may be needed when vertically terminating the vent
system above the roof (when using the appliance top vent), install a vent
If needed, install the restrictor as shown, either from inside or outside the
restrictor in the top vent of the fireplace outlet.
unit, in the inner fireplace collar.
Restrictor
Inner
Fireplace
Collar
Appliance Top
Vent Outlet
Figure 18
Determine the venting for the appliance. If the vent run will include at
least 8 feet of vertical rise, then install the restrictor in the appliance
collar before connecting any vent (Refer to Figure 19 ). Place the
restrictor inside the appliance vent collar and press in place.
Note: The restrictor is included within the firebox.
Select Venting System - Horizontal or Vertical
With the appliance secured in framing, determine vent routing and identify
the exterior termination location. The following sections describe vertical
(roof) and horizontal (exterior wall) vent applications. Refer to the section
relating to your installation. A list of approved venting components are
shown on Pages 39 and 40.
16
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Innovative Hearth Products
TRAHCHTGNELNOITCESTNEV
lanimoN
htgneLnoitceS
)sehcni(
621426384
T
O
T
A
L
Q
T
Y
noitceSteN
)sehcni(htgneL
2/1-42/1-012/1-222/1-432/1-64
tneVfothgieHsnoitceStneVforebmuN
sehcnitf
5.4573.0100001
957.0200002
5.01578.0010001
5152.1110002
5.91526.12100
0
3
1257.1020002
5.22578.1001001
5.52521.2120003
5.13526.2030003
5.43578.2000101
5.73521.3111003
5.34526.3021003
5457.3002002
5.64578.3000011
5.94521.4102003
1552.4100012
5.55526.4012003
7557.4001102
6652.5022004
5.76526.5003003
9657.5000202
276103004
5.37521.6100203
5.97526.6010203
1857.6000112
095.7021014
5.
19526.7002013
3957.7000022
698101204
5.79521.8100023
2015.8200024
5.301526.8000303
8019100304
4115.9020024
71157.9105006
5.811578.9110305
6215.01001304
5.031578.01101305
53152.11006006
8315.11000404
5.931526.11000033
5.241578.11100405
TRAHCHTGNELNOITCESTNEV
noitceSlanimoN
)sehcni(htgneL
621426384
T
O
T
A
L
Q
T
Y
noitceSteN
)sehcni(htgneL
2/1-42/1-012/1-222/1-432/1-64
tneVfothgieHsnoitceStneVforebmuN
sehcnitf
44121100034
0515.21010034
5.451578.21110035
5.061573.31020035
5.271573.41000505
77157.41100506
38152.51010506
6815.51000044
5.091578.51100045
5.691573.61010045
5.502521.71011507
70252.71000606
5.112526.71100607
5.712521.81010607
5.922521.91001607
5.232573.91000055
73257.91100056
5.142521.02000707
6425.02100708
25212010708
46222001708
67232000808
97252.32000066
5.
082573.32100809
5.382526.32100067
5.982521.42010067
5.103521.52001067
5.013578.52000909
5135.621009001
5.523521.72000077
0335.72100078
63382010078
54357.82000 01001
5.943521.92100 01011
27313000088
5.673573.13100089
5.973526.13000 11011
5.814578.43000099
32452.531000901
56457.8300000101
SV4.5CGV-1
Termination
SV4.5FA OR
SV4.5FB Flashing
AND SV4.5SC
STORM COLLAR
*SV4.5VF
Firestop/Spacer
SV4.5L6/12/24/36/48
Vent Sections
40' Max
(12.2 M)
1" (25.4 mm)
Minimum
Clearance to
Combustibles
*When using Secure Flex,
use Firestop/Spacer
SF4.5VF
SuperiorTM DRT35 See Through and Peninsula Direct Vent Gas Fireplace
VERTICAL TERMINATION SYSTEMS (ROOF)
See Figure 19 and Figures 29 through 34 on
Pages 20, 21 and 22 and their associated
Vertical Vent Tables which illustrate the various
vertical venting configurations that are possible
for use with these appliances. Secure Vent™
pipe applications are shown in these Figures;
Secure Flex™ pipe may also be used. A Vertical
Vent Table summarizes each system’s minimum
and maximum vertical and horizontal length
values that can be used to design and install the
vent components in a variety of applications.
Both these vertical vent systems terminate
through the roof. The minimum vent height
above the roof and/or adjacent walls is specified in ANSI Z223.1-(latest edition) (In Canada,
the current CAN/CSA-B149.1 installation code)
by major building codes. Always consult your
local codes for specific requirements. A general
guide to follow is the Gas Vent Rule (refer to
Figure 5 on Page 8).
Vertical (Straight) Installation
(Figure 19)
Determine the number of straight vent sections required. 4-1/2" (114 mm), 10-1/2" (267
mm), 22-1/2" (572 mm), 34-1/2" (876 mm)
and 46-1/2" (1181 mm) net section lengths
are available (see Tables on this page and Page 39 - Rigid Vent Sections). Plan the vent
lengths so that a joint does not occur at the
intersection of ceiling or roof joists. Refer to
the Vent Section Length Chart.
Figure 19
Installation and Operation Instructions
900300-00, 02/2015
Effective Vent Length
Note: Convert inches into metric equivalent
measurement, as follows:
Millimeters (mm) = Inches x 25.4
Centimeters (cm) = Inches x 2.54
Meters (M) = Inches x .0254
Align the dimple (four places)
with the opening of the locking
incline channel on appliance
collar. Twist vent component
clockwise to engage and seal.
Locking
Incline Channel
Dimple
Appliance collar
Vent / Appliance Collar
Connection
Connection
Arrow
SuperiorTM DRT35 See Through and Peninsula Direct Vent Gas Fireplace
Installation and Operation Instructions
900300-00, 02/2015
Vertical (Offset) Installation
Analyze the vent routing and determine the
quantities of vent sections and number of elbows required. Refer to Vertical Vent Figures and Tables on page 15 to select the type of
vertical installation desired. Vent sections are
available in net lengths of 4-1/2" (114 mm),
10-1/2" (267 mm), 22-1/2" (572 mm), 34-1/2"
(876 mm) and 46-1/2" (1181 mm). Refer to the
Effective Vent Length Chart on page 17 for an
aid in selecting length combinations. Elbows are
available in 90° and 45° configurations. Refer
to Figure 24 for the SV4.5E45 and SV4.5E90
elbow dimensional specifications.
Where required, a telescopic vent section (SV4.5LA) may be used to provide the installer
with an option in installing in tight and confined
spaces or where the vent run made up of fixed
length pieces develops a joint in a undesirable
location, or will not build up to the required
length. The SV4.5LA Telescopic Vent Section
has an effective length of from 1-1/2" (38 mm)
to 7-1/2" (191 mm). The SV4.5LA is fitted with
a locking inclined channel end (identical to a
normal vent section component) and a plain end
with 3 pilot holes. Slip the plain end over the
locking channel end of a standard SV4.5 vent
component the required distance and secure
with three screws.
Maintain a minimum 1" (25 mm) clearance to
combustible materials for all vertical elements.
Clearances for all horizontal elements are 3"
(76 mm) on top, 1" (25 mm) on sides and 1"
(25 mm) on the bottom.
A. Frame ceiling opening - Use a plumb line
from the ceiling above the appliance to locate
center of the vertical run. Cut and/or frame an
opening, 10-1/2" x 10-1/2" (267mm x 267mm)
inside dimensions, about this center mark
(Figure 20 ).
10-1/2" Min.
(267 mm)
Figure 20
18
10-1/2" Min.
(267 mm)
B. Attach vent components to appliance
- Secure Vent SV4.5 direct vent system compo-
nents are unitized concentric pipe components
featuring positive twist lock connections (see Figures 21 and 22 ).
All of the appliances covered in this document
are fitted with collars having locking inclined
channels. The dimpled end of the vent components fit over the appliance collar to create
the positive twist lock connection.
Figure 21
Align the dimple (four places) of the
upper vent section with the opening of
the locking incline channel on the
lower vent section. Twist vent
component clockwise to engage and
seal until arrow and dimple align.
Dimple
Locking
Incline Channel
Connected
Arrow
Vent Sections
Vent / Vent Section
Arrow
Figure 22
To attach a vent component to the appliance
collar, align the dimpled end over the collar,
adjusting the radial alignment until the four
locking dimples are aligned with the inlet of
the four inclined channels on the collar (refer to Figure 21). Push the vent component against
the collar until it fully engages, then twist the
component clockwise, running the dimples
down and along the incline channels until they
seat at the end of the channels. The unitized
design of the Secure Vent components will
engage and seal both the inner and outer pipe
without the need for sealant or screws. If desired
a #6 x 1/2" screw may be used at the joint, but
it is not required as the pipe will securely lock
when twisted.
Note: An elbow may also be attached to the
appliance collar. Attach in the same manner
as you would a vent section.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
C. Attach vent components to each other
- Other vent sections may be added to the
previously installed section in accordance with
the requirements of the vertical vent figures
and tables. To add another vent component
to a length of vent run, align the dimpled end
over the inclined channel end of the previously
installed section, adjusting the radial alignment
until the four locking dimples are aligned with
the inlets of the four incline channels of the
previous section.
Push the vent component against the previous
section until it fully engages, then twist the
component clockwise running the dimples down
and along the incline channels until they seat at
the end of the channels.This seating position
is indicated by the alignment of the arrow and
dimple as shown in Figure 22.
D. Install firestop/spacer at ceiling - When
using Secure Vent, use SV4.5VF firestop/spacer
at ceiling joists; when using Secure Flex, use
SF4.5VF firestop/spacer. If there is living space
above the ceiling level, the firestop/spacer must
be installed on the bottom side of the ceiling.
If attic space is above the ceiling, the firestop/
spacer must be installed on the top side of
the joist. Route the vent sections through the
framed opening and secure the firestop/spacer
with 8d nails or other appropriate fasteners at
each corner. Remember to maintain 1" (25
mm) clearance to combustibles, framing
members, and attic or ceiling insulation
when running vertical chimney sections.
Attic insulation shield (96K94) may be used
to obtain the required clearances indicated
here. See installation accessories tables on
pages 39 and 40.
SV4.5FA or
SV4.5FB Flashing
and SV4.5SC
Storm Collar
vWhen
using
secure
Flex, use
Firestop/
Spacer
SF4.5VF
Ceiling
Framing
SV4.5CGV-1
Termination
1” (25.4 mm)
Minimum
Clearance to
Combustibles
v SV4.5VF
Firestop / spacer
uSV4.5SP
Support Plate
uSV4.5SU
Support Strap
Shown With
Optional
Radiant
Panels
8 ft. (2.4 M)
Maximum
uSecured
to Vent with
Appropriate
Fasteners
Figure 23
Innovative Hearth Products
SV4.5E90
(90
°
Elbow)
8-1/8"
(206 mm)
Swivel Joint
(360
°
swivel)
4-13/16"
(122 mm)
SV4.5E45
(45
°
Elbow)
Swivel Joint
(360
°
swivel)
C
D
Storm
Collar
SuperiorTM DRT35 See Through and Peninsula Direct Vent Gas Fireplace
Installation and Operation Instructions
900300-00, 02/2015
F. Change vent direction to horizontal/inclined
run - At transition from or to a horizontal/in-
clined run, install the SV4.5E45 and SV4.5E90
elbows in the same manner as the straight vent
sections. The elbows feature a twist section to
allow them to be routed about the center axis
of their initial collar section to align with the
required direction of the next vent run element.
Twist elbow sections in a clockwise direction
only so as to avoid the possiblity of unlocking
any of the previously connected vent sections.
See Figure 24.
E.Support the vertical vent run sections -
Note - Proper venting support is very important.
The weight of the vent must not be supported
by the fireplace in any degree.
Support the vertical portion of the venting
system every 8 feet (2.4m) above the fireplace
vent outlet. One method of support is by utilizing field provided support straps (conventional
plumber's tape). Secure the plumber's tape to
the framing members with nails or screws.
Loop the tape around the vent, securing the
ends of the tape to the framing. If desired,
sheet metal screws #6 x 1/2" length may be
used to secure the support straps to the vent
pipe. See Figure 23.
H.Frame roof opening - Identify location for
vent at the roof. Cut and/or frame opening per
Roof Framing Chart and Figure 25.
Framing Dimensions for Roof
Pitch C D
0/12 10-1/2 in. 10-1/2 in.
(267 mm) (267 mm)
6/1210-1/2 in. 12 in.
(267 mm) (305 mm)
12/1210-1/2 in. 17-3/4 in.
(267 mm) (451 mm)
Figure 25
I.Install the roof flashing - Extend the vent
sections through the roof structure. Install the
roof flashing over the vent section and position such that the vent column rises vertically
(use carpenters level) (Figure 26 ). Nail along
perimeter to secure flashing or adjust roofing
to overlap the flashing edges at top and sides
only and trim where necessary. Seal the top
and both sides of the flashing with waterproof
caulking.
Figure 27
K. Install the vertical termination - The final
step involves installation of the SV4.5CGV-1
Vertical Termination. Extend the vent sections
to the height as shown in the "Vertical vent termination section" on page 6. The SV4.5CGV-1
Vertical Termination (Figure 28 ) installs in the
exact same fashion as any other Secure Vent
section. Align the termination over the end of
the previously installed section, adjusting the
radial alignment until the four locking dimples
of the termination are aligned with the inlets of
the four incline channels of the last vent section.
Push the termination down until it fully engages,
then twist the termination clockwise running the
dimples down and along the incline channels
until they seat at the end of the channels.
Figure 24
G. Continue installation of horizontal/inclined
sections - Continue with the installation of the
straight vent sections in horizontal/inclined run
as described in Step C. Install support straps
every 5' (1.52 m) along horizontal/inclined vent
runs using conventional plumber’s tape. It is
very important that the horizontal/inclined
run be maintained in a straight (no dips) and
slightly elevated plane in a direction away
from the fireplace 1/4" per foot (20 mm per
meter) of horizontal vent. Use a carpenter’s
level to measure from a constant surface and
adjust the support straps as necessary.
It is important to maintain the required clearances to combustibles: 1" (25 mm) at all sides
for all vertical runs; and 3" (76 mm) at the top,
1" (25 mm) at sides, and 1" (25 mm) at the
bottom for all horizontal/inclined runs.
Figure 26
J. Install the storm collar - Install the storm
collar, supplied with the flashing, over the
vent/flashing joint. See Figure 27. Loosen the
storm collar screw. Slide collar down until it
meets the top of the flashing. Tighten the adjusting screw. Apply non-combustible caulking or
mastic around the circumference of the joint
to provide a water tight seal.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Figure 28
If the vent system extends more than 5' (1.5
m) above the roof flashing, stabilizers may be
necessary. Additional screws may be used at
section joints for added stability. Guide wires
may be attached to the joint for additional support on multiple joint configurations.
19
Innovative Hearth Products
V1
SuperiorTM DRT35 See Through and Peninsula Direct Vent Gas Fireplace
Installation and Operation Instructions
900300-00, 02/2015
VERTICAL VENT FIGURES/TABLES
Note:Secure Vent (rigid vent pipe) is shown
in the figures; Secure Flex (flexible vent pipe)
may also be used.
Note: It is very important that the horizontal/
inclined run be maintained in a straight (no
dips) and recommended to be in a slightly
elevated plane, in a direction away from the
fireplace of 1/4" rise per foot (20 mm per meter)
which is ideal, though rise per foot run ratios
that are smaller are acceptable all the way down
to at or near level.
Note: SV4.5VF (Secure Vent), SF4.5VF (Secure
Flex) firestop/spacer must be used anytime vent
pipe passes through a combustible floor or ceiling. SV4.5HF (Secure Vent), SF4.5HF (Secure
Flex)firestop/spacer must be used anytime vent
pipe passes through a combustible wall.
Note: Two 45 degree elbows may be used in
place of one 90 degree elbow. The same rise
to run ratios, as shown in the venting figures
for 90 elbows, must be followed if 45 degree
elbows are used.
Note: An elbow is acceptable as 1 foot of
vertical rise, except where an elbow is the
only vertical component in the system. (See
Figure 38 on page 24 ).
WARNING
Under no circumstances, may separate sections of concentric flexible
vent pipe be joined together.
Example: If 8 feet of (H) horizontal vent run is needed, then 4 feet minimum (V) vertical vent will be
required.
This table shows a 1(V) to 2(H) ratio. For every 1 foot of (V) vertical, you are allowed 2 feet of (H)
horizontal run, up to a maximum horizontal run of 8 feet.
u When using Secure Flex, use Firestop / Spacer SF4.5VF
v When using Secure Flex, use Firestop / Spacer SF4.5HF
Example: If 20 feet total (H+H1) horizontal vent run is needed,
then 4 feet minimum of (V) vertical vent will be required.
This table shows a 1(V) to 5(H) ratio. For every 1 foot of (V)
vertical, you are allowed 5 feet of (H+H1) horizontal run up to a
maximum total horizontal run of 20 feet.
u When using Secure Flex, use Firestop / Spacer SF4.5VF
v When using Secure Flex, use Firestop / Spacer SF4.5HF
Example: If 20 feet total (H+H1) horizontal vent run is needed, then 4 feet minimum
of (V) vertical vent will be required.
This table shows a 1(V) to 5(H) ratio. For every 1 foot of (V) vertical, you are allowed
5 feet of (H+H1) horizontal run up to a maximum total horizontal run of 20 feet.
H
Ceiling
u
Firestop / Spacer
(SV4.5VF)
Wall Firestop/
v
Spacer (SV4.5HF)
H
V
H
1
An elbow is acceptable as 1 foot of vertical rise except where an elbow is the only
vertical component in the system. See Figure 38.
Figure 33- Top Vent - THREE ELBOWS
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
21
Loading...
+ 49 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.