Super X8DT3, X8DTi, X8DT3-F, X8DTi-F, X8DT3-LN4F User Manual

...
Page 1
X8DT3 X8DTi
X8DT3-F
X8DTi-F
X8DTi-LN4F
USER’S MANUAL
Revision 1.0a
Page 2
The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccuracies that may be contained in this document, makes no commitment to update or to keep current the information in this manual, or to notify any person or organization of the updates. Please Note: For the most up-to-date version of this
manual, please see our web site at www.supermicro.com.
Super Micro Computer, Inc. ("Supermicro") reserves the right to make changes to the product described in this manual at any time and without notice. This product, including software, if any, and documentation may not, in whole or in part, be copied, photocopied, reproduced, translated or reduced to any medium or machine without prior written consent.
IN NO EVENT WILL SUPERMICRO BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL, SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO USE THIS PRODUCT OR DOCUMENTATION, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. IN PARTICULAR, SUPERMICRO SHALL NOT HAVE LIABILITY FOR ANY HARDWARE, SOFTW ARE, OR DA TA STORED OR USED WITH THE PRODUCT, INCLUDING THE COSTS OF REPAIRING, REPLACING, INTEGRATING, INSTALLING OR RECOVERING SUCH HARDWARE, SOFTWARE, OR DATA.
Any disputes arising between manufacturer and customer shall be governed by the laws of Santa Clara County in the State of California, USA. The State of California, County of Santa Clara shall be the exclusive venue for the resolution of any such disputes. Super Micro's total liability for all claims will not exceed the price paid for the hardware product.
FCC Statement: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the manufacturer’s instruction manual, may cause harmful interference with radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case you will be required to correct the interference at your own expense.
California Best Management Practices Regulations for Perchlorate Materials: This Perchlorate warning applies only to products containing CR (Manganese Dioxide) Lithium coin cells. “Perchlorate Material-special handling may apply. See www.dtsc.ca.gov/hazardouswaste/perchlorate”
WARNING: Handling of lead solder materials used in this product may expose you to lead, a chemical known to the State of California to cause birth defects and other reproductive harm.
Manual Revision 1.0a Release Date: April 30, 2009
Unless you request and receive written permission from Super Micro Computer, Inc., you may not copy any part of this document.
Information in this document is subject to change without notice. Other products and companies referred to herein are trademarks or registered trademarks of their respective companies or mark holders.
Copyright © 2009 by Super Micro Computer, Inc. All rights reserved.
Printed in the United States of America
Page 3
Preface
About this Manual
This manual is written for system integrators, PC technicians and knowledgeable PC users. It provides information for the installation and use of the X8DTi/X8DT3-F/X8DTi-F/X8DT3-LN4F/X8DTi-LN4F motherboard.
About this Motherboard
The X8DT3/X8DTi/X8DT3-F/X8DTi-F/X8DT3-LN4F/X8DTi-LN4F supports the Intel® 5500 Series Processor platform, the fi rst dual-processing platform that supports the Intel QuickPath Interconnect (QPI) Technology, providing the next gen­eration point-to-point system interface to replace the current Front Side Bus. With the 5500 Series Processor platform built in, the X8DT3/X8DTi/X8DT3-F/X8DTi-F/ X8DT3-LN4F/X8DTi-LN4F offers substantial enhancement in system performance with increased bandwidth and unprecedented scalability optimized for high-end servers, High Performance Computing (HPC) systems and intensive applications. Please refer to our web site (http://www.supermicro.com/products/) for updates on supported processors. This product is intended to be installed and serviced by professional technicians.
Preface
X8DT3/
Manual Organization
Chapter 1 describes the features, specifi cations and performance of the mother-
board and provides detailed information about the chipset. Chapter 2 provides hardware installation instructions. Read this chapter when in-
stalling the processor, memory modules and other hardware components into the system. If you encounter any problems, see Chapter 3, which describes trouble­shooting procedures for video, memory and system setup stored in the CMOS.
Chapter 4 includes an introduction to the BIOS and provides detailed information on running the CMOS Setup utility.
Appendix A lists BIOS POST Error Codes. Appendix B and Appendix C provide the Windows OS and Other Software Installation Instructions.
Conventions Used in the Manual
Special attention should be given to the following symbols for proper installation and to prevent damage done to the components or injury to yourself:
Danger/Caution: Instructions to be strictly followed to prevent catastrophic system failure or to avoid bodily injury.
iii
Page 4
X8DT3/X8DTi/X8DT3-F/X8DTi-F/X8DT3-LN4F/X8DTi-LN4F User's Manual
Warning: Important information given to ensure proper system installation or to prevent damage to the components.
Note: Additional Information given to differentiate various models or to ensure correct system setup.
iv
Page 5
Contacting Supermicro
Contacting Supermicro
Headquarters
Address: Super Micro Computer, Inc.
980 Rock Ave. San Jose, CA 95131 U.S.A.
Tel: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: [email protected] (General Information)
[email protected] (Technical Support)
Web Site: www.supermicro.com
Europe
Address: Super Micro Computer B.V.
Het Sterrenbeeld 28, 5215 ML 's-Hertogenbosch, The Netherlands
Tel: +31 (0) 73-6400390 Fax: +31 (0) 73-6416525 Email: [email protected] (General Information)
[email protected] (Technical Support) [email protected] (Customer Support)
Asia-Pacifi c
Address: Super Micro Computer, Inc.
4F, No. 232-1, Liancheng Rd. Chung-Ho 235, Taipei County Taiwan, R.O.C.
Tel: +886-(2) 8226-3990 Fax: +886-(2) 8226-3991 Web Site: www.supermicro.com.tw Technical Support: Email: [email protected] Tel: 886-2-8228-1366, ext.132 or 139
v
Page 6
X8DT3/X8DTi/X8DT3-F/X8DTi-F/X8DT3-LN4F/X8DTi-LN4F User's Manual
Table of Contents
Preface ...........................................................................................................3
About this Manual ......................................................................................................... 3
About this Motherboard ................................................................................................. 3
Manual Organization ..................................................................................................... 3
Conventions Used in the Manual .................................................................................. 3
Contacting Supermicro .................................................................................................. 5
Chapter 1 Introduction ............................................................................. 1-1
1-1 Overview .........................................................................................................1-1
Checklist ..........................................................................................................1-1
Quick Reference ............................................................................................. 1-5
Motherboard Features ................................................................................... 1-6
1-3 Chipset Overview ............................................................................................1-9
Main Features of the 5500 Series Processor and the 5520 Chipset .............1-9
1-4 Special Features ........................................................................................... 1-10
Recovery from AC Power Loss ..................................................................... 1-10
1-5 PC Health Monitoring .................................................................................... 1-10
Fan Status Monitor with Firmware Control ..................................................1-10
Environmental Temperature Control .............................................................1-10
System Resource Alert ................................................................................. 1-10
1-6 ACPI Features ................................................................................................1-11
Slow Blinking LED for Suspend-State Indicator ............................................1-11
Main Switch Override Mechanism .................................................................1-11
Wake-On-LAN (WOL) ....................................................................................1-11
1-7 Power Supply ................................................................................................1-12
1-8 Super I/O ....................................................................................................... 1-12
1-9 Overview of the Winbond WPCM450 Controller (For X8DT3/i-F/X8DT3/i-LN4F
Only) ......................................................................................................................1-13
Chapter 2 Installation ..............................................................................2-1
2-1 Static-Sensitive Devices .................................................................................. 2-1
Precautions .....................................................................................................2-1
Unpacking .......................................................................................................2-1
2-2 Motherboard Installation .................................................................................. 2-2
Tools Needed .................................................................................................. 2-2
Installation Instructions ....................................................................................2-2
2-3 Processor and Heatsink Installation................................................................2-3
Installing a CPU Heatsink ...............................................................................2-5
2-4 Memory Installation ........................................................................................ 2-7
vi
Page 7
Table of Contents
2-5 Control Panel Connectors/IO Ports...............................................................2-10
1. Back Panel Connectors/IO Ports .............................................................. 2-10
ATX PS/2 Keyboard and PS/2 Mouse Ports .............................................2-11
Universal Serial Bus (USB) ...................................................................... 2-12
Serial Ports ............................................................................................... 2-13
Video Connector .......................................................................................2-13
Ethernet Ports .......................................................................................... 2-14
2. Front Control Panel ...................................................................................2-15
3. Front Control Panel Pin Defi nitions .......................................................... 2-16
NMI Button ............................................................................................... 2-16
Power LED ..............................................................................................2-16
HDD LED .................................................................................................. 2-17
NIC1/NIC2 LED Indicators ....................................................................... 2-17
Overheat (OH)/Fan Fail LED....................................................................2-18
Power Fail LED ........................................................................................ 2-18
Reset Button ........................................................................................... 2-19
Power Button ........................................................................................... 2-19
2-6 Connecting Cables ........................................................................................ 2-20
Power Connectors ...................................................................................2-20
Fan Headers ............................................................................................. 2-21
Chassis Intrusion .....................................................................................2-21
Internal Speaker .......................................................................................2-22
Power LED/Speaker ................................................................................. 2-22
Wake-On-LAN ..........................................................................................2-23
Overheat LED/Fan Fail (JOH1) ................................................................2-23
T-SGPIO Headers ....................................................................................2-24
I-Button (Optional for X8DT3/-F/LN4F only) ............................................ 2-24
Power SMB (I IPMB I
2
C SMB .......................................................................................... 2-25
2
C) Connector .................................................................... 2-25
2-7 Jumper Settings ............................................................................................ 2-26
Explanation of Jumpers ................................................................................ 2-26
GLAN Enable/Disable .............................................................................. 2-26
CMOS Clear .............................................................................................2-27
Watch Dog Enable/Disable ...................................................................... 2-27
2
I
C Bus to PCI-Exp. Slots ........................................................................ 2-28
VGA Enable .............................................................................................. 2-28
SAS Enable/Disable (X8DT3/X8DT3-F/X8DT3-LN4F only) ..................... 2-29
SAS RAID Select (X8DT3/X8DT3-F/ X8DT3-LN4F only) ........................2-29
2-8 Onboard LED Indicators ............................................................................... 2-30
vii
Page 8
X8DT3/X8DTi/X8DT3-F/X8DTi-F/X8DT3-LN4F/X8DTi-LN4F User's Manual
GLAN LEDs .............................................................................................. 2-30
IPMI Dedicated LAN LEDs (X8DT3/i-F/-LN4F Only) ............................... 2-30
SAS Heartbeat/Activity LED Indicators ....................................................2-31
BMC Heartbeat LED ................................................................................ 2-31
Onboard Power LED ............................................................................... 2-32
2-9 Floppy Drive, Serial ATA and SAS Connections ........................................... 2-33
Floppy Connector .....................................................................................2-33
Serial ATA Ports........................................................................................2-34
SAS Ports (X8DT3/X8DT3-F/X8DT3-LN4F only) .....................................2-34
Chapter 3 Troubleshooting ..................................................................... 3-1
3-1 Troubleshooting Procedures ........................................................................... 3-1
Before Power On ............................................................................................ 3-1
No Power ........................................................................................................ 3-1
No Video ......................................................................................................... 3-2
Losing the System’s Setup Confi guration ....................................................... 3-2
Memory Errors ............................................................................................... 3-2
3-2 Technical Support Procedures ........................................................................ 3-3
3-3 Frequently Asked Questions ........................................................................... 3-3
3-4 Returning Merchandise for Service.................................................................3-4
Chapter 4 BIOS .........................................................................................4-1
4-1 Introduction ...................................................................................................... 4-1
4-2 Main Setup ......................................................................................................4-2
4-3 Advanced Setup Confi gurations...................................................................... 4-4
4-4 Security Settings ........................................................................................... 4-23
4-5 Boot Confi guration ........................................................................................4-24
4-6 Exit Options ................................................................................................... 4-26
4-7 BIOS Recovery ............................................................................................. 4-27
Appendix A BIOS Error Beep Codes ..................................................... A-1
A-1 BIOS Error Beep Codes ................................................................................. A-1
Appendix B Installing the Windows OS ............................................... B-1
B-1 Installing the Windows OS to a RAID System ................................................ B-1
B-2 Installing the Windows OS to a Non-RAID System ........................................B-2
Appendix C Software Installation Instructions ....................................C-1
C-1 Installing Software Programs ......................................................................... C-1
C-2 Confi guring Supero Doctor III .........................................................................C-2
viii
Page 9
Chapter 1: Introduction
Chapter 1
Introduction
1-1 Overview
Checklist
Congratulations on purchasing your computer motherboard from an acknowledged leader in the industry. Supermicro boards are designed with the utmost attention to detail to provide the highest standards in quality and performance. Check that the following items have all been included with your motherboard. If anything listed here is damaged or missing, contact your retailer.
The following items are included in the retail box.
One (1) Supermicro Mainboard
•
One (1) fl oppy ribbon cable (CBL-0022L) •
One (1) USB cable (CBL-0083L)•
One (1) Serial/COM cable (CBL-010L)•
Four (4) Serial ATA cables (CBL-0044L) (For X8DT3/X8DT3-F/X8DT3-LN4F)•
Six (6) Serial ATA cables (CBL-0044L) (For X8DTi/X8DTi-F/X8DTi-LN4F)•
Two (2) SAS cable for SATA/SAS Backplane (CBL-0097L-02) (For X8DT3/• X8DT3-F/X8DT3-LN4F)
One (1) I/O backpanel shield (MCP-260-00027-0N)
•
One (1) Supermicro CD containing drivers and utilities•
One (1) User's/BIOS Manual•
1-1
Page 10
X8DT3/X8DTi/X8DT3-F/X8DTi-F/X8DT3-LN4F/X8DTi-LN4F User's Manual
X8DT3/X8DTi/X8DT3-F/X8DTi-F/X8DT3-LN4F/X8DTi-LN4F Image
Note: The drawings and pictures shown in this manual were based on the
latest PCB Revision available at the time of publishing of the manual. The motherboard you’ve received may or may not look exactly the same as the graphics shown in the manual.
1-2
Page 11
Chapter 1: Introduction
KB/MOUSE
USB 0/1
COM1
VGA
Fan8/ CPU2 FAN
LAN1 LAN3
LAN2 LAN4
LAN
CTRL
LAN
CTRL
(X8DT3/i-LN4F)
X8DT3/i Series
Battery
COM2
JPL1 JPL2
X8DT3/X8DTi/X8DT3-F/X8DTi-F/X8DT3-LN4F/X8DTi-LN4F Layout
ICH10R
South Bridge
USB3
USB2
J6
CPU1
P1-DIMM1B
P1-DIMM1A
P1-DIMM2B
P1-DIMM2A
P1-DIMM3B
P1-DIMM3A
Intel 5520
North Bridge
LES2
LES1
LSI
1068E
(*X8DT3 Models only)
JPT1
I-SATA1
I-SATA0
JWD
JL1
T-SGPIO2
I-SATA5
I-SATA4
T-SGPIO1
I-BUTTON
I-SATA3
I-SATA2
Fan6
Fan5
Dedicated LAN
(X8DT3/i-F/-LN4F only)
JLAN1
JLAN2
JI2C1
JI2C2
JPW2
P2-DIMM3A
P2-DIMM3B
P2-DIMM2A
P2-DIMM2B
P2-DIMM1A
P2-DIMM1B
Slot6 PCI-E 2.0x8
Slot5 PCI-E 2.0x8 in x16
Slot4 PCI-E 2.0 x16
Slot3
PCI 33 MHz
Slot2 PCI-E x4
J26
Slot1 PCI 33MHz
CPU2
SPEC
BMC/VGA
JPB
CTRL
D1
JPG1
J27J28
BIOS
JPW3
JBT1
USB6/7
JUSB3
USB4/5
JUSB2
JPW1
Fan1
SP1
LE1
SI/O
Floppy
J5
SAS4~7
JSM2
(*X8DT3 Models only)
SAS0~3
JSM1
JWOL
JPS2
JPS1
Fan4
Fan7/ CPU1
JOH1
Fan2
JF1
Fan3
JD1
1
1
1
Differences between the models
X8DT3 X8DTi X8DT3-F X8DTi-F X8DT3-LN4F X8DTi-LN4F
SATA (ICH10R) Yes Yes Yes Yes Yes Yes
SAS (1068E) Yes No Yes No Yes No
I-Button Optional No Optional No Optional No
IPMI 2.0 w/KVM No No Yes Yes Yes Yes
LAN3/LAN4 &
JPL2 (Jumper)
No No No No Yes Yes
Notes
LAN Port 3, LAN Port 4, and LAN Controller#2 are for the X8DT3/i-LN4F 1. only. IPMI Dedicated LAN is for X8DT3/i-F, X8DT3/i-LN4F only.
SAS connectors, jumpers, and the LSI 1068E chip are available on the 2. X8DT3/-F/-LN4F only. For SAS RAID confi guration, refer to the LSI User Guide posted on our website @ http://www.supermicro.com/support/manuals/
IPMI 2.0 and the Dedicated LAN (w/KVM support) are available on the 3. X8DT3/i-F/-LN4F only. For more information, please refer to the user guide posted on our website @ http://www.supermicro.com/support/manuals/
1-3
Page 12
X8DT3/X8DTi/X8DT3-F/X8DTi-F/X8DT3-LN4F/X8DTi-LN4F User's Manual
Motherboard Layout
KB/MOUSE
USB 0/1
COM1
VGA
Fan8/ CPU2 FAN
LAN1 LAN3
LAN2 LAN4
LAN
CTRL
LAN
CTRL
(X8DT3/i-LN4F)
X8DT3/i Series
Battery
COM2
JPL1
JPL2
Notes
Jumpers not indicated are for test purposes only. 1.
Fan6
Fan5
Dedicated LAN
(X8DT3/i-F/-LN4F only)
JLAN1
JLAN2
JI2C1
JI2C2
JPW2
P2-DIMM3A
P2-DIMM3B
P2-DIMM2A
P2-DIMM2B
P2-DIMM1A
P2-DIMM1B
Slot6 PCI-E 2.0x8
Slot5 PCI-E 2.0x8 in x16
Slot4 PCI-E 2.0 x16
Slot3
PCI 33 MHz
Slot2 PCI-E x4
J26
Slot1 PCI 33MHz
CPU2
SPEC
BMC/VGA
JPB
CTRL
D1
JPG1
J27J28
BIOS
JBT1
USB6/7
JUSB3
JPW3
USB4/5
JUSB2
ICH10R
South Bridge
USB3
USB2
J6
CPU1
P1-DIMM1B
P1-DIMM1A
P1-DIMM2B
P1-DIMM2A
P1-DIMM3B
P1-DIMM3A
Intel 5520
North Bridge
LES2
LES1
LSI
1068E
(*X8DT3 Models only)
JPT1
I-SATA1
JWD
I-SATA0
T-SGPIO2
I-SATA5
I-SATA4
T-SGPIO1
I-BUTTON
I-SATA3
I-SATA2
JL1
JPW1
Fan1
SP1
LE1
SI/O
Floppy
J5
SAS4~7
JSM2
(*X8DT3 Models only)
SAS0~3
JSM1
JWOL
JPS2
JPS1
Fan4
Fan7/ CPU1
JOH1
Fan2
JF1
Fan3
JD1
1
1
1
Jumper J 26 is res er ved for inter nal test ing onl y. The manufac turer 's defau lt 2. setting is on Pins 1 & 2 . Do not c hange t he manuf actur er's d efault se ttin g.
Jumper JPB is reserved for internal use only. Do not change the manufac-3. turer's default setting.
For IPMI confi guration,4. please refer to the Winbond BMC User's Guide posted on our website @ http://www.supermicro.com/support/manuals/.
" " indicates the location of Pin 1. Also, refer to Chapter 2 for detailed infor-5. mation on the onboard components.
When LE1 is on, the onboard power connection is on. Make sure to unplug 6. the power cables before removing or installing components.
To avoid possible system overheating, be sure to provide adequate airfl ow 7. to the system.
1-4
Page 13
Chapter 1: Introduction
Quick Reference
Jumper Description Default Setting
JBT1 CMOS Clear (See Section 5-10)
2
C1/JI2C2 SMB to PCI Slots 2-3 (Disabled)
JI
JPG1 VGA Enable Pins 1-2 (Enabled)
JPL1/JPL2 LAN1/2 & LAN 3/4 Enable Pins 1-2 (Enabled) (JP2: for LN4 models)
JPS1 SAS Enable Pins 1-2 (Enabled) (Note 5 P. 1-4)
JPS2 SAS RAID Enable Closed (SR RAID Enabled) (Note5 P1-4)
JWD Watch Dog Pins 1-2 (Reset)
Connector Description
COM1/COM2 COM1/COM2 Serial Port/Header
FAN 1-8 System/CPU Fan Headers (Fans 7~8: CPU Fans)
Floppy Floppy Disk Drive Connector
I-Button I-Button for data storage (optional for X8DT3/-F/LN4F only)
2
J5 IPMB I
J6 Power Supply SMBbus I
C Header (for an IPMI card)
2
C Header JD1 PWR LED/Speaker Header (Pins 4~7: Speaker) JF1 Front Panel Connector JL1 Chassis Intrusion Header JOH1 Overheat LED Header JPW1/JPW2, JPW3 8-pin Secondary PWR, 24-pin ATX PWR (See Warning) JWOL Wake-On-LAN Header LAN1/2, 3/4, Dedicated
Gigabit Ethernet (RJ45) Ports (See Note 5 on P. 1-4)
LAN I-SATA0 ~ I-SATA5 (Intel South Bridge) SATA Ports SAS 0~3, 4~7 SAS Ports 0~3, 4~7 (X8DT3/-F/-LN4F only) T-SGPIO-1/T-SGPIO-2 Serial General Purpose Input/Output Headers USB 0/1, 2,3, 4/5, 6/7 Universal Serial Bus (USB) Ports VGA VGA Con nec tor
LED Description
D1 BMC Heartbeat LED Indicator LE1 Onbo ard St and by LED Ind ica tor LES1/LES2 SAS LEDs (LES1: SAS Heartbeat, LES2: SAS Activity LEDs)
Warning: To prevent damage to the power supply or motherboard, please use a power supply that contains a 24-pin and two 8-pin power connectors. Be sure to connect these connectors to the 24-pin (JPW3) and the two 8-pin (JPW1,JPW2) power connectors on the motherboard. Failure in doing so will void the manufacturer warranty on your power supply and motherboard.
1-5
Page 14
X8DT3/X8DTi/X8DT3-F/X8DTi-F/X8DT3-LN4F/X8DTi-LN4F User's Manual
Motherboard Features
CPU
Two Intel• full-width Intel QuickPath Interconnect links with a total of up to 51.2 GB/s Data Transfer Rate (6.4 GB/s per direction)
®
5500 Series (LGA 1366) processors, each processor supporting two
Memory
Twelve 240-pin DIMM sockets support up to 96 GB of DDR3 Registered ECC • Memory (See Section 2-4 in Chapter 2 for DIMM Slot Population.)
Chipset
Intel 5520 chipset, including: the 5520 (North Bridge) and the ICH10R (South • Bridge).
Expansion Slots
One PCI-E 2.0 x16 slot (Slot 4) (X8DTi/X8DTi-F only)• Three PCI-E 2.0 x8 (in x16) slots (Slot 5/Slot 6, and Slot 4 for X8DT3/X8DT3-F/•
X8DTi/3-LN4 only) One PCI-E x4 slot (Slot 2) or Two PCI-E 2.0 x8 slots (for X8DTi/ X8DTi-F)
•
Two 32-bit PCI 33 slot (Slot 1 and Slot 3)•
BIOS
32 Mb AMI SPI Flash ROM• PCI 2.2, ACPI 1.0/2.0/3.0, Plug and Play (PnP), DMI 2.3, Wakeup, USB Key-•
board support, and SMBIOS 2.3
PC Health Monitoring
Onboard voltage monitors for CPU1 Vcore/CPU2 Vcore, CPU1 DIMM/CPU2 • DIMM, 1.5V, 3.3Vcc (V), 3.3V SB (V), 12Vcc (V), 5Vin, and Battery Voltage.
Fan status monitor with fi rmware control
•
CPU/chass is temper ature moni tors• Platfo rm Enviro nment Co ntrol Inte rf ace (PECI) read y• Ther mal Mo nitor 2 ( TM2) supp or t• CPU fan auto - of f in sle ep mode• CPU slow- dow n on tempe rature over heat• Pulse Wi dth Mo dulati on (PW M) Fan Contr ol • CPU ther mal tr ip supp or t for pro ces sor pr otecti on, power L ED• Power-up mod e cont rol for r ecover y fr om AC power l oss• Auto- switc hing vol tage r egulato r for CPU c ore s• System over heat /Fan Fail LED I ndic ator and c ontr ol• Chassis i ntrus ion detec tion•
1-6
Page 15
Chapter 1: Introduction
System re sourc e aler t vi a Super o Doc tor III•
ACPI Features
Slow blinking LED for suspend state indicator• Main switch override mechanism• ACPI Pow er Ma nag eme nt• Keyboard Wakeup from Soft-off •
Onboard I/O
Intel ICH10R supports six SATA2 ports (with RAID0, RAID1, RAID10, RAID5 • supported in the Windows OS Environment) (Note 1)
LSI 1068E supports eight SAS ports (with RAID 5 optional) (For X8DT3/-F/-
•
LN4F) (Note 2) Intel 82576EB dual-port Gigabit Ethernet controllers support Giga-bit LAN
•
por ts (an addit ional 8 2576EB is ava ilabl e on the X8 DT3/ i- LN4F o nly) One fl oppy por t inter fac e and t wo COM po rt s (1 header, 1 port)
•
One VGA Por t supp or ted by the W PCM4 50 BM C Cont rolle r• PS/2 mo use and PS /2 keyboa rd por ts• Up to eigh t USB 2.0 (Uni versal S erial Bus) (2 Back panel USB Po rts, 2 Fro nt •
USB Hea ders , and 2 Type A Header s) Super I/ O: Winbo nd W83 627HG
•
IPMI 2.0 w ith fu ll K VM supp or t (X8DT 3/i -F/- LN4F o nly) (Note 3)•
Other
Wake-on-LAN (WOL)• Console redirection• Onboa rd Fan Spee d Contr ol by Ther mal Ma nagem ent via BI OS•
CD/Diskette Utilities
BIOS fl ash upgrade utility and device drivers•
Dimensions
Ext . ATX 12.00" (L) x 13.00 " (W ) (304. 80 mm x 3 30. 20 mm)•
Note 1: For more information on SATA HostRAID confi guration, please refer to the Intel SATA HostRAID User's Guide posted on our website @ http://www.supermicro.com/support/manuals/.
Note 2: For more information on LSI SAS RAID confi guration, please refer to the LSI MegaRAID User's Guide posted on our website @ http://www. supermicro.com/support/manuals/.
Note 3: For more information on IPMI confi guration, please refer to the Embedded IPMI User's Guide posted on our website @ http://www.super­micro.com/support/manuals/.
1-7
Page 16
X8DT3/X8DTi/X8DT3-F/X8DTi-F/X8DT3-LN4F/X8DTi-LN4F User's Manual
#4
PHY#1
X16 SLOT
PHY#2
PCI-E X16/8
Ports#0~3
Ports#4~7
PHY#1
PHY#2
#1-2
#1-1
DDRIII
LAN#2
82576EB
Option
SAS LSI 1068 B3 Option
LAN#1 82576EB
BMC WPCM450
#1-6
#1-5
#1-4
#1-3
800/1066/1333
(Optional)
Port
#7
Port
PCI-E X4
#8
PCI-E X4
#6
PCI-E X8
#5
PCI-E X8
PCI-E X8
SPEC
#2
PCI-33
#3
PCI-33
#1
VRD VRD
6 PHASE 6 PHASE
PROCESSOR#2
PCI-E X16
PCI-E X4
PCI-E X8
PCI 33MHz
QPI
Ports
Ports #1-2
Ports
#3-4
Ports
#5-6
PCI-E X8
LANE 1/2/3/4
LANE5 LANE6
SPI
QPI
#7-10
Intel 5520
Port
ESI
DMI
Intel ICH10R
PROCESSOR#1
QPI
#0
PCIE X4
LPC
SIO
W83627
HG
3.0 Gb/S
USB 2.0
#0
#0
TPM
#1
#1
#0-1
#2
#2
#0-5
#0-4
#0-3
#0-2
DDRIII
800/1066/1333
#5
#4
#3
SATA
28 #5
#3
USB
#6
#0-6
#8
#7
#9
Note: This is a general block diagram. Please see the previous Mother­board Features pages for details on the features of each motherboard.
MS KB
COM1 External
Block Diagram of the 5520 Platform
1-8
COM2 internal
Page 17
Chapter 1: Introduction
1-3 Chipset Overview
Built upo n the capabili ty of the Intel 5 520 platfor m, the X8DT3/ X8DTi/X8 DT3- F/ X8DTi- F/X8DT3 -LN4F/X8 DTi-LN4 F motherboa rd provides the p erfor mance and feature set r equired for dual -proce ssor-based hig h-end syste ms with confi gura- tion optimized for workstations, High Performance Computing (HPC) systems, and intensi ve applicati ons. The 5520 p latfor m consists of t he 550 0 Series (LGA
1366) processor, the 5520 (North Bridge), and the ICH10R (South Bridge). With the Quic kPath Inter conne ct (QPI) contr oller bui lt in, the 5 520 platf orm is th e fi rst dual-processing platform that offers the next generation point-to-point system interco n n ect interface to replace the curre nt Fro nt S ide Bus Technology, substan­tially enhancing system performance with increased bandwidth and scalability.
The 5520 North Bridge connects to each processor through an independent Quick­Path Interconnect link. Each link consists of 20 pairs of unidirectional differential lanes for data transferring in addition to a di fferential f orwarded clock. A full-width QuickPath interconnect link pair provides 84 signals. Each processor supports two Quick Path links, o ne goin g to the othe r proc esso r and the ot her to th e 5520.
The 5520 platform supports up to 36 PCI Express Gen2 lanes, peer-to-peer read and write transactions. The ICH1 0R provides up to 6 PCI-Express ports, six SATA por ts and 10 US B conn ecti ons.
In additi on, the 5 520 plat for m also of fers a w ide ran ge of R AS (Relia bilit y, Avail­ability and Serviceability) features. These features include memory interface ECC, x4/x8 S ingle Devic e Data C orrec tion (SDD C), Cyclic Redund ancy Chec k (CRC), parity protection, out-of-band register access via SMBus, memory mirroring, memor y spa ring, a nd Hot- plug su ppor t on t he PCI -E xpre ss Inter f ace.
Main Features of the 5500 Series Processor and the 5520 Chipset
Four processor cores in each processor with 8MB shared cache among cores•
Two full-width Intel QuickPath interconnect links, up to 6.4 GT/s of data transfer • rate in each direction
Virtualization Technology, Integrated Management Engine supported
•
Point-to-point cache coherent interconnect, Fast/narrow unidirectional links, and • Concurrent bi-directional traffi c
Error detection via CRC and Error correction via Link level retry
•
1-9
Page 18
X8DT3/X8DTi/X8DT3-F/X8DTi-F/X8DT3-LN4F/X8DTi-LN4F User's Manual
1-4 Special Features
Recovery from AC Power Loss
BIOS provides a setting for you to determine how the system will respond when AC power is lost and then restored to the system. You can choose for the system to remain powered off (in which case you must hit the power switch to turn it back on) or for it to automatically return to a power- on state. See the Advanced BIOS Setup section to change this setting. The default setting is Last State.
1-5 PC Health Monitoring
This section describes the PC health monitoring features of the X8DT3/X8DTi/ X8DT3-F/X8DTi-F/X8DT3-LN4F/X8DTi-LN4F. All have an onboard System Hard­ware Monitor chip that supports PC health monitoring. An onboard voltage monitor will scan these onboard voltages continuously: CPU1 Vcore/CPU2 Vcore, CPU1 DIMM/CPU2 DIMM, 1.5V, 3.3Vcc (V), 3.3V SB (V), 12Vcc (V), 5Vin, and Battery Voltage. Once a voltage becomes unstable, a warning is given or an error mes­sage is sent to the screen. Users can adjust the voltage thresholds to defi ne the sensitivity of the voltage monitor.
Fan Status Monitor with Firmware Control
The PC health monitor can check the RPM status of the cooling fans. The onboard CPU and chassis fans are controlled by Thermal Management via BIOS (under Hardware Monitoring in the Advanced Setting).
Environmental Temperature Control
The thermal control sensor monitors the CPU temperature in real time and will turn on the thermal control fan whenever the CPU temperature exceeds a user-defi ned threshold. The overheat circuitry runs independently from the CPU. Once it detects that the CPU temperature is too high, it will automatically turn on the thermal fan control to prevent any overheat damage to the CPU. The onboard chassis thermal circuitry can monitor the overall system temperature and alert users when the chas­sis temperature is too high.
To avoid possible system overheating, please be sure to provide adequate airfl ow to your system.
System Resource Alert
This feature is available when used with Supero Doctor III in the Win dows OS
1-10
Page 19
Chapter 1: Introduction
environment or used with Supero Doctor II in Linux. Supero Doctor is used to notif y the user of cer tain system events. For example, you can also confi gure Supero Doctor to provide you with warnings when the system temperature, CPU temperat ures, volt ages a nd fan spe eds go beyon d a pre- defi ned range.
1-6 ACPI Features
ACPI stands for Advanced Confi guration and Power Interface. The ACPI specifi ca- tion defi nes a fl exible and abstract hardware interface that provides a standard way to integrate power management features throughout a PC system, including its hardware, operating system and application software. This enables the system to automatically turn on and off peripherals such as CD-ROMs, network cards, hard disk drives and printers.
In addition to enabling operating system-directed power management, ACPI provides a generic system event mechanism for Plug and Play and an operating system-independent interface for confi guration control. ACPI leverages the Plug and Play BIOS data structures while providing a processor architecture-independent implementation that is compatible with the Windows XP/2003/2008/Vista Operating System.
Slow Blinking LED for Suspend-State Indicator
When the CPU goes into a suspend state, the chassis power LED will start blinking to indicate that the CPU is in suspend mode. When the user presses any key, the CPU will wake-up and the LED will automatically stop blinking and remain on.
Main Switch Override Mechanism
When an ATX power supply is used, the power button can function as a system suspend button to make the system enter a SoftOff state. The monitor will be suspended and the hard drive will spin down. Pressing the power button again will cause the whole system to wake-up. During the SoftOff state, the ATX power supply provides power to keep the required circuitry in the system "alive." In case the system malfunctions and you want to turn off the power, just press and hold the power button for 4 seconds. This option can be set in the Power section of the BIOS Setup routine.
Wake-On-LAN (WOL)
Wake-On-LAN is defi ned as the ability of a management application to remotely power up a computer that is powered off. Remote PC setup, up-dates and asset tracking can occur after hours and on weekends so that daily LAN traffi c is kept to a minimum and users are not interrupted. The motherboard has a 3-pin header
1-11
Page 20
X8DT3/X8DTi/X8DT3-F/X8DTi-F/X8DT3-LN4F/X8DTi-LN4F User's Manual
(WOL) to connect to the 3-pin header on a Network Interface Card (NIC) that has WOL capability. In addition, an onboard LAN controller can also support WOL without any connection to the WOL header. The 3-pin WOL header is to be used with a LAN add-on card only.
Note: Wake-On-LAN requires an ATX 2.01 (or above) compliant power supply.
1-7 Power Supply
As with all computer products, a stable power source is necessary for proper and reliable operation. It is even more important for processors that have high CPU clock rates.
The X8DT3/X8DTi/X8DT3-F/X8DT i-F/X8DT3-LN4F/X8DT i-LN4F can accommodate 24-pin ATX power supplies. Although most power supplies generally meet the specifi cations required by the CPU, some are inadequate. In addition, the two 12V 8-pin power connections are also required to ensure adequate power supply to the system. Also your power supply must supply 1.5A for the Ethernet ports.
Warning: To prevent damage to the power supply or motherboard, please use a power supply that contains a 24-pin and two 8-pin power connectors. Be sure to connect these connectors to the 24-pin (JPW3) and the two 8-pin (JPW1,JPW2) power connectors on the motherboard for adequate power supply to your system. Failure in doing so will void the manufacturer warranty on your power supply and motherboard.
It is strongly recommended that you use a high quality power supply that meets ATX power supply Specifi cation 2.02 or above. It must also be SSI compliant (For more information, please refer to the web site at http://www.ssiforum.org/). Additionally, in areas where noisy power transmission is present, you may choose to install a line fi lter to shield the computer from noise. It is recommended that you also install a power surge protector to help avoid problems caused by power surges.
1-8 Super I/O
The disk drive adapter functions of the Super I/O chip include a fl oppy disk drive controller that is compatible with industry standard 82077/765, a data separator, write pre-compensation circuitry, decode logic, data rate selection, a clock genera­tor, drive interface control logic and interrupt and DMA logic. The wide range of functions integrated onto the Super I/O greatly reduces the number of components required for interfacing with fl oppy disk drives. The Super I/O supports 360 K, 720 K, 1.2 M, 1.44 M or 2.88 M disk drives and data transfer rates of 250 Kb/s, 500 Kb/s or 1 Mb/s. It also provides two high-speed, 16550 compatible serial communication ports (UARTs). Each UART includes a 16-byte send/receive FIFO, a programmable
1-12
Page 21
Chapter 1: Introduction
baud rate generator, complete modem control capability and a processor interrupt system. Both UARTs provide legacy speed with baud rate of up to 115.2 Kbps as well as an advanced speed with baud rates of 250 K, 500 K, or 1 Mb/s, which support higher speed modems.
The Super I/O provides functions that comply with ACPI (Advanced Confi guration and Power Interface), which includes support of legacy and ACPI power manage­ment through an SMI or SCI function pin. It also features auto power management to reduce power consumption.
1-9 Overview of the Winbond WPCM450 Controller (For X8DT3/i-F/X8DT3/i-LN4F Only)
The Winbond WPCM450 Controller is a Baseboard Management Controller (BMC) that supports the 2D/VGA-compatible Graphics Core with the PCI interface, Virtual Media, and Keyboard/Video/Mouse Redirection (KVMR) modules. With blade-oriented Super I/O capability built-in, the WPCM450 Controller is ideal for legacy-reduced server platforms.
The WPCM450 interfaces with the host system via a PCI interface to communicate with the Graphics core. It supports USB 2.0 and 1.1 for remote keyboard/mouse/ virtual media emulation. It also provides LPC interface to control Super IO functions. The WPCM450 is connected to the network via an external Ethernet Phy module.
The WPCM450 communicates with onboard components via six SMBus interfaces, fan control, and Platform Environment Control Interface (PECI) buses.
1-13
Page 22
X8DT3/X8DTi/X8DT3-F/X8DTi-F/X8DT3-LN4F/X8DTi-LN4F User's Manual
Notes
1-14
Page 23
Chapter 2: Installation
Chapter 2
Installation
2-1 Static-Sensitive Devices
Electrostatic Discharge (ESD) can damage electronic com ponents. T o prevent dam­age to your system board, it is important to handle it very carefully. The following measures are generally suffi cient to protect your equipment from ESD.
Precautions
Use a grounded wrist strap designed to prevent static discharge.•
Touch a grounded metal object before removing the board from the antistatic • bag.
Handle the board by its edges only; do not touch its components, peripheral
•
chips, memory modules or gold contacts.
When handling chips or modules, avoid touching their pins.
•
Put the motherboard and peripherals back into their antistatic bags when not • in use.
For grounding purposes, make sure your computer chassis provides excellent
•
conductivity between the power supply, the case, the mounting fasteners and the motherboard.
Use only the correct type of onboard CMOS battery as specifi ed by the
•
manufacturer. Do not install the onboard battery upside down to avoid possible explosion.
Unpacking
The motherboard is shi p ped in antistati c p ackaging to avoid st atic damage. When unpacking the board, make sure the person handling it is static protected.
2-1
Page 24
X8DT3/X8DTi/X8DT3-F/X8DTi-F/X8DT3-LN4F/X8DTi-LN4F User's Manual
2-2 Motherboard Installation
All motherboards have standard mounting holes to fi t different types of chassis. Make sure that the locations of all the mounting holes for both motherboard and chassis match. Although a chassis may have both plastic and metal mounting fasteners, metal ones are highly recommended because they ground the mother­board to the chassis. Make sure that the metal standoffs click in or are screwed in tightly. Then use a screwdriver to secure the motherboard onto the motherboard tray. Note: Some components are very close to the mounting holes. Please take precautionary measures to prevent damage to these components when installing the motherboard to the chassis.
Tools Needed
1. Phillips Screwdriver
Locations of Mounting Holes
2. Pan head #6 screws
Installation Instructions
Install the IO shield into the chassis. 1.
Locate the mounting holes on the motherboard. Refer to the layout above for 2. mounting hole locations.
Locate the matching mounting holes on the chassis. Align the mounting holes 3. on the motherboard against the mounting holes on the chassis.
Install standoffs in the chassis as needed.4.
Install the motherboard into the chassis carefully to avoid damage to mother-5. board components.
Warning: To avoid damaging the motherboard and its components, please do not apply any force greater than 8 lb/sq.in (8 lbs. per square inch) when installing a screw into a mounting hole.
X8DT3/i Series
Insert a Pan head #6 screw into a mounting hole on the motherboard and its 6. matching mounting hole on the chassis, using a Phillips screwdriver.
Repeat Step 4 to insert #6 screws to all mounting holes.7.
Make sure that the motherboard is securely placed on the chassis.8.
2-2
Page 25
2-3 Processor and Heatsink Installation
!
When handling the processor package, avoid placing direct pressure on the label area of the fan.
Notes:
Always connect the power cord last and always remove it before adding, re-1. moving or changing any hardware components. Make sure that you install the processor into the CPU socket before you install the CPU heatsink.
Make sure to install the motherboard into the chassis before you install the 2. CPU heatsink and heatsink fans.
When purchasing a 5500 Series processor or when receiving a motherboard 3. with a 5500 Series processor pre-installed, make sure that the CPU plastic cap is in place, and none of the CPU pins are bent; otherwise, contact the retailer immediately.
Chapter 2: Installation
Refer to the M B Features S ecti on for mo re deta ils on CPU s uppor t.4.
Installing an LGA 1366 Processor
Press the socket clip to release 1. the load plate, which covers the CPU socket, from its locking position.
Gently lift the socket clip to 2. open the load plate.
Hold the plastic cap at its north 3. and south center edges to re­move it from the CPU socket.
Socket Clip
Plastic Cap
Load Plate
Hold the north & south edges of the plastic cap to remove it
2-3
Page 26
X8DT3/X8DTi/X8DT3-F/X8DTi-F/X8DT3-LN4F/X8DTi-LN4F User's Manual
After removing the plastic cap, 1. using your thumb and the index fi nger, hold the CPU at the
CPU CPU SocketLoad Plate
north and south center edges.
Align the CPU key, the semi-2. circle cutout, against the socket key, the notch below the gold color dot on the side of the socket.
Once both the CPU and the 3. socket are aligned, carefully lower the CPU straight down
Socket Keys
into the socket. (Do not rub the CPU against the surface of the socket or its pins to avoid dam­aging the CPU or the socket.)
With the CPU inside the socket, 4. inspect the four corners of the CPU to make sure that the CPU is properly installed.
Once the CPU is securely 5. seated on the socket, lower the CPU load plate to the socket.
Use your thumb to gently push 6. the socket clip down to the clip lock.
Warning: Please save th e plastic cap. The mother­board must be shipped with the plastic cap prop­erly ins tal led to p rotec t the CPU socket pins. Ship­ment without the plastic cap properly installed will cause damage to the sock­et pins.
CPU Keys
2-4
Page 27
Installing a CPU Heatsink
Do not apply any thermal 1. grease to the heatsink or the CPU die because the required amount has already been ap­plied.
Chapter 2: Installation
Place the heatsink on top of the 2. CPU so that the four mounting holes are aligned with those on the retention mechanism.
Install two diagonal screws (ie 3. the #1 and t he #2 s crews) and tighten them until just snug (-do not f ully tig hten the sc rews to avoid possible damage to the CPU.)
Screw#1
Screw#1
Install Screw#1
Screw#2
Screw#2
Finish the installation by fully 4. tightening all four screws.
2-5
Page 28
X8DT3/X8DTi/X8DT3-F/X8DTi-F/X8DT3-LN4F/X8DTi-LN4F User's Manual
Removing the Heatsink
Warni ng: We do not recommend that the CPU or the heatsink be re­moved. However, if you do need to remove the heatsink, please follow the inst ructions be low to uninstall th e heatsink and prevent da mage to the CPU or ot her co mpone nts.
Unplug the power cord from the 1. power supply.
Disconnect the heatsink fan 2. wires from the CPU fan header.
Using a screwdriver, loosen and 3. remove the heatsink screws from the motherboard in the se­quence as show in the picture on the right.
Using a screwdriver to remove Screw#1
Hold the heatsink as shown 4. in the picture on the right and gently wriggle the heatsink to loosen it from the CPU. (Do not use excessive force when wrig­gling the heatsink.)
Once the CPU is loosened, 5. remove the heatsink from the CPU socket.
To reinstall the CPU and the 6. heatsink, clean the surface of the CPU and the heatsink to get rid of the old thermal grease. Reapply the proper amount of thermal grease on the surface before reinstalling them on the motherboard.
Remove Screw#2
2-6
Page 29
Chapter 2: Installation
2-4 Memory Installation
Note: Check the S uper micro we b site for r ecom mende d memor y mo dules .
CAUTION
Exercise extreme care when installing or removing DIMM
module s to prevent any po ssib le damag e. Also n ote that th e
memor y is i nterl eaved to imp rove per fo rman ce (See ste p 1).
DIMM Installation
Insert the desired number of DIMMs into the memory slots, starting with 1. DIMM #P1-DIMM1A. When populating two DIMM modules within a channel, always start with Bank1 fi rst. For optimal memory performance, please install a pair (or pairs) of memory modules of the same type and same speed at a time with the maximum of 12 modules. (See the Memory Installation Table on Page 2-8.)
Insert each DIMM module vertically into its slot. Pay attention to the notch 2. along the bottom of the module to prevent inserting the DIMM module incor­rectly.
Gently press down on the DIMM module until it snaps into place in the slot. 3. Repeat for all modules.
DIMM DDR3
Note: Notch
should align
with the
receptive point
on the slot
3
X8DT3/i Series
To Remove:
Use your thumbs to gently push the release tabs near both ends of the module. This should release it from the slot.
To In s ta l l : In ser t mo dule ve r tic ally a nd pre ss do wn unt il it snaps in to plac e. Pay at tent ion to t he ali gnme nt notc h at the bottom.
Release Tab
Notch
Release
Tab
Notch
Release
Tab
Release Tab
2-7
Page 30
X8DT3/X8DTi/X8DT3-F/X8DTi-F/X8DT3-LN4F/X8DTi-LN4F User's Manual
Memory Population for Optimal Performance
-For a motherboard with One CPU (CPU1) installed
Branch 0 Branch 1 Branch 2
3 DIMMs P1 DIMM1A P1 DIMM2A P1 DIMM3A 6 DIMMs P1 DIMM1A P1 DIMM1B P1 DIMM2A P1 DIMM2B P1 DIMM3A P1 DIMM3B
Memory Population for Optimal Performance
-For a motherboard with One CPU (CPU2) installed
Branch 0 Branch 1 Branch 2
3 DIMMs P2 DIMM1A P2 DIMM2A P2 DIMM3A 6 DIMMs P2 DIMM1A P2 DIMM1B P2 DIMM2A P2 DIMM2B P2 DIMM3A P2 DIMM3B
Memory Population for Optimal Performance
-For a motherboard with Two CPUs installed
CPU1 CPU2
Branch 0 Branch 1 Branch 3 Branch 0 Branch 1 Branch 3
6 DIMMs 1A 2A 3A 1A 2A 3A 12
DIMMs
1A 1B 2A 2B 3A 3B 1A 1B 2A 2B 3A 3B
Memory Support
The X8DT3/X8DTi/X8DT3-F/X8DTi-F/X8DT3-LN4F/X8DTi-LN4F supports up to 96 GB Registered ECC DDR3 1333 MHz/1066 MHz/800 MHz in 12 DIMMs. Please note that Memory Speed support is also depending on the type of CPU used in the motherboard.
DIMM Module Population Confi guration
For memor y to wor k pro perl y, follow the tab les be low for me mor y inst allati on:
DIMM Population Table
DIMM Slots per Channel
2 1 Reg. DDR3 ECC 800,1066,1333 SR or DR 2 1 Reg. DDR3 ECC 800,1066 QR 2 2 Reg. DDR3 ECC 800,1066 Mixing SR, DR 2 2 Reg. DDR3 ECC 800 Mixing SR, DR,QR
DIMMs Populated per Channel
DIMM Type (Reg.= Registered)
Speeds (in MHz) Ranks per DIMM
(any combination; SR=Single Rank, DR=Dual Rank, QR=Quad Rank)
Note 1: Due to OS limitations, some operating systems may not show
more than 4 GB of memory. Note 2: Due to memory allocation to system devices, the amount of
memory that remai ns avai labl e fo r ope rat io nal us e wi ll be r educ e d whe n
2-8
Page 31
Chapter 2: Installation
4 GB of R A M is us ed. T he re duc tio n in me mor y ava ilab ili ty i s disp rop or­tiona l. (See the fo llowi ng Mem or y Availabi lity Table.)
Possible System Memory Allocation & Availability
System Device Size Physical Memory
Firmware Hub fl ash memory (System BIOS)
Local APIC 4 KB 3.99 GB Area Reserved for the chipset 2 MB 3.99 GB I/O APIC (4 Kbytes) 4 KB 3.99 GB PCI Enumeration Area 1 256 MB 3.76 GB PCI Express (256 MB) 256 MB 3.51 GB PCI Enumeration Area 2 (if needed)
-Aligned on 256-MB boundary­VGA Memory 16 MB 2.85 GB TSEG 1 MB 2.84 GB Memory available for the OS & other
applications
1 MB 3.99 GB
512 MB 3.01 GB
Remaining (-Available) (4 GB Total System Memory)
2.84 GB
2-9
Page 32
X8DT3/X8DTi/X8DT3-F/X8DTi-F/X8DT3-LN4F/X8DTi-LN4F User's Manual
1
2
3
45678
9
2-5 Control Panel Connectors/IO Ports
The I/O p ort s are col or cod ed in co nforma nce wit h the PC 9 9 speci fi cation. See the pic ture be low for t he co lors a nd loc atio ns of the var ious I /O por t s.
1. Back Panel Connectors/IO Ports
11
X8DT3/i Series
Back Panel I/O Port Locations and Defi nitions
Back Panel Connectors
Keyboard (Purple)1.
PS/2 Mouse (Green)2.
Back Panel USB Port 03.
Back Panel USB Port 14.
Dedicated LAN (X8DT3/i-F/ X8DT3/i-LN4F only)5.
COM Port 1 (Turquoise)6.
VGA (Blue) 7.
Gigabit LAN 18.
Gigabit LAN 3 (for X8DT3-LN4F/X8DTi-LN4F only)9.
Gigabit LAN 210.
Gigabit LAN 4 (for X8DT3-LN4F/X8DTi-LN4F only)(See 11.
Sect ion 2- 5 for d etail s.)
10
2-10
Page 33
Chapter 2: Installation
1
2
ATX PS/2 Keyboard and PS/2 Mouse Ports
The ATX PS/2 keyboard and PS/2 mouse are located next to the Back Panel USB Ports 0~1 on the moth­erboard. See the table at right for pin defi nitions.
Mouse
Keyboard
PS/2 Keyboard/Mouse Pin
Defi nitions
PS2 Keyboard PS2 Mouse Pin# Defi nition Pin# Defi nition 1 KB Data 1 Mouse Data 2 No Connection 2 No Connection 3 Ground 3 Ground
4 Mouse/KB VCC
(+5V) 5 KB Clock 5 Mouse Clock 6 No Connection 6 No Connection VCC: with 1.5A PTC (current limit)
4 Mouse/KB VCC
(+5V)
X8DT3/i Series
1. Keyboard (Purple)
2. Mouse (Green)
2-11
Page 34
X8DT3/X8DTi/X8DT3-F/X8DTi-F/X8DT3-LN4F/X8DTi-LN4F User's Manual
2
1
2
1
5
6
3
4
Universal Serial Bus (USB)
Two Universal Serial Bus ports (USB 0 and USB 1) are located on the I/O back panel. Additionally, six USB con­nections (USB 2, 3, 4/5, 6/7) on the motherboard to provide front chassis access. (Cables are not included). See the tables on the right for pin defi nitions.
Back Panel USB
(USB 0/1)
Pin# Defi nitions 1 +5V 2 PO­3 PO+ 4 Ground 5 N/A
Front Panel USB
Pin Defi nitions (USB4/5/6/7)
USB 4/6 Pin # Defi nition
1 +5V 1 +5V 2 PO- 2 PO­3 PO+ 3 PO+ 4 Ground 4 Ground 5 Key 5 No connection
Front Panel USB
(USB 2/3)
Pin# Defi nition 1 Vcc 2 Data­3 Data+ 4 Ground 5NA
USB 5/7 Pin # Defi nition
X8DT3/i Series
1. Backpanel USB 0
2. Backpanel USB 1
3. Front Panel USB 2
4. Front Panel USB 3
5. Front Panel USB 4/5
6. Front Panel USB 6/7
2-12
Page 35
Chapter 2: Installation
1
2
1
3
Serial Ports
Two COM connections (COM1 & COM2) are located on the motherboard. COM1 is located on the Backplane IO panel. COM2 is located next to the onboard battery to provide additional onboard serial connection support. See the table on the right for pin defi nitions.
Video Connector
A Video (VGA) connector is located next to COM Port1 on the IO back­plane. This connector is used to provide video display. Refer to the board layout below for the location.
Serial Ports-COM1/COM2
Pin Defi nitions
Pin # Defi nition Pin # Defi nition 1 DCD 6 DSR 2 RXD 7 RTS 3 TXD 8 CTS 4 DTR 9 RI 5 Ground 10 N/A
X8DT3/i Series
1. COM1
2. COM2
3. VGA
COM2
2-13
Page 36
X8DT3/X8DTi/X8DT3-F/X8DTi-F/X8DT3-LN4F/X8DTi-LN4F User's Manual
1
2
1
2
3
4
3
4
5
5
Ethernet Ports
Two Ethernet ports (LAN 1/LAN2) are located at on the IO backplane. In addition, LAN 3/LAN4 are supported on the X8DT3/i-LN4F. A dedicated LAN is also located on the X8DT3/i-F/ X8DT3/i-LN4F to provide KVM sup­port for IPMI 2.0. All these ports ac­cept RJ45 type cables. (Note: Please refer to the LED Indicator Section for LAN LED information.)
LAN Ports
Pin Defi nition
Pin# Defi nition 1 P2V5SB 10 SGND 2 TD0+ 11 Act LED 3 TD0- 12 P3V3SB 4 TD1+ 13 Link 100 LED
(Yellow, +3V3SB)
5 TD1- 14 Link 1000 LED
(Yellow, +3V3SB) 6 TD2+ 15 Ground 7 TD2- 16 Ground 8 TD3+ 17 Ground 9 TD3- 88 Ground
(NC: No Connection)
X8DT3/i Series
1. LAN1
2. LAN2
3. LAN3 (X8DT3/i-LN4F only)
4. LAN4 (X8DT3/i-LN4F only)
5. LAN5 (X8DT3/i-F/-LN4F only)
2-14
Page 37
Chapter 2: Installation
2. Front Control Panel
JF1 contains header pins for various buttons and indicators that are normally lo­cated on a control panel at the front of the chassis. These connectors are designed specifi cally for use with Supermicro server chassis. See the fi gure below for the descriptions of the various control panel buttons and LED indicators. Refer to the following section for descriptions and pin defi nitions.
JF1 Header Pins
1920
Ground
NMI
X8DT3/i Series
X
Power LED
HDD LED
NIC1 LED
NIC2 LED
OH/Fan Fail LED
PWR Fail LED
Ground
Ground
X
Vcc
Vcc
Vcc
Vcc
Vcc
Vcc
Reset
PWR
2
1
Reset Button
Power Button
2-15
Page 38
X8DT3/X8DTi/X8DT3-F/X8DTi-F/X8DT3-LN4F/X8DTi-LN4F User's Manual
3. Front Control Panel Pin Defi nitions
NMI Button
The non-maskable interrupt button header is located on pins 19 and 20 of JF1. Refer to the table on the right for pin defi nitions.
Power LED
The Power LED connection is located on pins 15 and 16 of JF1. Refer to the table o n the ri ght for p in defi nitions.
NMI Button
Pin Defi nitions (JF1)
Pin# Defi nition 19 Control 20 Ground
Power LED
Pin Defi nitions (JF1)
Pin# Defi nition 15 +5V 16 Ground
X8DT3/i Series
2-16
A. NMI B. PWR LED
Ground
X
B
Power LED
HDD LED
NIC1 LED
NIC2 LED
OH/Fan Fail LED
PWR Fail LED
Ground
Ground
1920
A
NMI
X
Vcc
Vcc
Vcc
Vcc
Vcc
Vcc
Reset
Reset Button
Power Button
PWR
2
1
Page 39
HDD LED
Chapter 2: Installation
The HDD LED connection is located on pins 13 and 14 of JF1. Attach a hard drive LED cable here to display disk activity (for any hard drive ac­tivities on the system, including SAS, Serial ATA and IDE). See the table on the right for pin defi nitions.
NIC1/NIC2 LED Indicators
The NIC (Network Interface Control­ler) LED connection for GLAN port 1 is located on pins 11 and 12 of JF1, and the LED connection for GLAN Port 2 is on Pins 9 and 10. Attach the NIC LED cables to display network activity . Refer to the table on the right for pin defi nitions.
HDD LED
Pin Defi nitions (JF1)
Pin# Defi nition 13 +5V 14 HD Active
GLAN1/2 LED
Pin Defi nitions (JF1)
Pin# Defi nition 9/11 Vcc 10/12 Ground
X8DT3/i Series
2-17
A. HDD LED B. NIC1 LED C. NIC2 LED
Ground
Power LED
A
HDD LED
B
NIC1 LED
C
NIC2 LED
OH/Fan Fail LED
PWR Fail LED
Ground
Ground
1920
NMI
X
2
X
Vcc
Vcc
Vcc
Vcc
Vcc
Vcc
Reset
Reset Button
Power Button
PWR
1
Page 40
X8DT3/X8DTi/X8DT3-F/X8DTi-F/X8DT3-LN4F/X8DTi-LN4F User's Manual
Overheat (OH)/Fan Fail LED
Connect an LED Cable to the OH/ Fan Fail conn ection o n pins 7 and 8 of JF1 to provide ad vanc ed wa rn ing s of chass is overhe ating or fa n failure. Refer to the t able o n the ri ght for p in defi nitions.
Power Fail LED
The Power Fail LED connection is locate d on pins 5 and 6 of JF1. Re­fer to the table on the right for pin defi nitions.
OH/Fan Fail LED
Pin Defi nitions (JF1)
Pin# Defi nition 7 Vcc 8 Ground
OH/Fan Fail Indicator
Status
State Defi nition Off Normal On Overheat Flash-
ing
Fan Fail
PWR Fail LED
Pin Defi nitions (JF1)
Pin# Defi nition 5 Vcc 6 Ground
X8DT3/i Series
2-18
A. OH/Fan Fail LED B. PWR Supply Fail
Ground
X
Power LED
HDD LED
NIC1 LED
NIC2 LED
OH/Fan Fail LED
A
B
PWR Fail LED
Ground
Ground
1920
NMI
X
Vcc
Vcc
Vcc
Vcc
Vcc
Vcc
Reset
Reset Button
Power Button
PWR
2
1
Page 41
Reset Button
Chapter 2: Installation
The Reset Button connection is located on pins 3 and 4 of JF1. Attach it to a hardware reset switch on the computer case. Refer to the table on the right for pin defi nitions.
Power Button
The Power Button connection is located on pins 1 and 2 of JF1. Momentarily con­tacting both pins will power on/off the sys­tem. This button can also be confi gured to function as a suspend button (with a setting in the BIOS - see Chapter 4). To turn off the power when set to suspend mode, press the button for at least 4 seconds. Refer to the table on the right for pin defi nitions.
Reset Button
Pin Defi nitions (JF1)
Pin# Defi nition 3 Reset 4 Ground
Power Button
Pin Defi nitions (JF1)
Pin# Defi nition
1 Signal 2 +3V Standby
X8DT3/i Series
2-19
A. Reset Button B. PWR Button
Ground
X
Power LED
HDD LED
NIC1 LED
NIC2 LED
OH/Fan Fail LED
PWR Fail LED
Ground
Ground
1920
NMI
X
Vcc
Vcc
Vcc
Vcc
Vcc
Vcc
Reset
PWR
2
1
A
Reset Button
B
Power Button
Page 42
X8DT3/X8DTi/X8DT3-F/X8DTi-F/X8DT3-LN4F/X8DTi-LN4F User's Manual
2-6 Connecting Cables
Power Connectors
A 24-pin main power supply connector(JPW3) and two 8-pin CPU PWR connectors (JPW1/ JPW2) on the motherboard. These power connectors meet the SSI EPS 12V specifi - cation. In addition to the 24-pin ATX power connector, the 12V 8-pin CPU PWR connec­tors at JPW1/JPW2 must also be connected to your power supply. See the table on the right for pin defi nitions.
Warning: To prevent damage to the power supply or motherboard, please use a power supply that contains a 24-pin and two 8-pin power connectors. Be sure to connect these connectors to the 24-pin (JPW3) and the two 8-pin (JPW1,JPW2) power connectors on the motherboard. Failure in do­ing so will void the manufacturer warranty on your power supply and motherboard.
ATX Power 24-pin Connector
Pin Defi nitions
Pin# Defi nition Pin # Defi nition 13 +3.3V 1 +3.3V 14 -12V 2 +3.3V 15 COM 3 COM 16 PS_ON 4 +5V 17 COM 5 COM 18 COM 6 +5V 19 COM 7 COM 20 Res (NC) 8 PWR_OK 21 +5V 9 5VSB 22 +5V 10 +12V 23 +5V 11 +12V 24 COM 12 +3.3V
(Required)
12V 8-pin PWR Connector
Pin Defi nitions
Pins Defi nition 1 through 4 Ground 5 through 8 +12V
(Required)
KB/MOUSE
USB 0/1
COM1
VGA
Fan8/ CPU2 FAN
LAN1 LAN3
LAN2
LAN4
LAN CTRL
LAN CTRL
(X8DT3/i-LN4F)
X8DT3/i Series
Battery
COM2
JPL1 JPL2
Fan6
Fan5
Dedicated LAN
(X8DT3/i-F/-LN4F only)
JLAN1
JLAN2
JI2C1
JI2C2
C
JPW2
P2-DIMM3A
P2-DIMM3B
P2-DIMM2A
P2-DIMM2B
P2-DIMM1A
P2-DIMM1B
Slot6 PCI-E 2.0x8
Slot5 PCI-E 2.0x8 in x16
Slot4 PCI-E 2.0 x16
Slot3
PCI 33 MHz
Slot2 PCI-E x4
J26
Slot1 PCI 33MHz
CPU2
SPEC
BIOS
BMC/VGA
CTRL
D1
JPB
JPG1
J27J28
A
JBT1
USB6/7
JUSB3
JPW3
J6
JPW1
Fan1
B
A. 24-pin ATX PWR (Req'd) B/C.8-pin Processor PWR
USB4/5
JUSB2
ICH10R
South Bridge
USB3
CPU1
Fan7/ CPU1
SP1
JOH1
SAS4~7
SAS0~3
JD1
Fan2
LE1
1
JF1
1
Fan3
SI/O
Floppy
1
J5
JSM2
JSM1
JWOL
JPS2
Fan4
P1-DIMM1B
P1-DIMM1A
P1-DIMM2B
P1-DIMM2A
P1-DIMM3B
P1-DIMM3A
Intel 5520
North Bridge
LES2
LES1
I-BUTTON
(*X8DT3 Models only)
I-SATA1
I-SATA0
1068E
JPT1
LSI
(*X8DT3 Models only)
JPS1
JWD
JL1
T-SGPIO1
T-SGPIO2
I-SATA5
I-SATA3
USB2
I-SATA4
I-SATA2
(Req'd)
2-20
Page 43
D
E
F
Fan Headers
G
This motherboard has six chassis/system fan headers (Fan1 to Fan6) and two CPU fans (Fan7/Fan8) on the motherboard. All these 4-pin fans headers are backward compatible with the traditional 3-pin fans. However, fan speed control is available for 4-pin fans only. The fan speeds are controlled by Thermal Management via Hardware Monitoring in the Advanced Setting in the BIOS. (The Default setting is Disabled.) See the table on the right for pin defi nitions.
Chapter 2: Installation
Fan Header
Pin Defi nitions
Pin# Defi nition 1 Ground 2 +12V 3 Tachometer 4 PWR Modulation
Chassis Intrusion
A Chassis Intrusion header is located at JL1 on the motherboard. Attach an appropriate cable from the chassis to inform you of a chassis intrusion when the chassis is opened.
KB/MOUSE
USB 0/1
COM1
VGA
LAN1 LAN3
LAN2 LAN4
LAN CTRL
LAN
CTRL
(X8DT3/i-LN4F)
X8DT3/i Series
Battery
COM2
Fan5
Dedicated LAN
(X8DT3/i-F/-LN4F only)
Fan8/
H
CPU2 FAN
JLAN1
JLAN2
JI2C1 JI2C2
JPL1 JPL2
Fan6
Slot6 PCI-E 2.0x8
Slot5 PCI-E 2.0x8 in x16
Slot4 PCI-E 2.0 x16
Slot3
Slot2 PCI-E x4
Slot1 PCI 33MHz
JPW2
PCI 33 MHz
SPEC
BMC/VGA
CTRL
JPB
JPW3
BIOS
JBT1
D1
USB4/5
USB6/7
JPG1
J27J28
JUSB3
P2-DIMM3A
P2-DIMM3B
P2-DIMM2A
P2-DIMM2B
P2-DIMM1A
P2-DIMM1B
CPU2
J26
JUSB2
ICH10R
South Bridge
USB3
J6
Intel 5520
North Bridge
T-SGPIO1
T-SGPIO2
I-BUTTON
I-SATA5
I-SATA3
USB2
I-SATA4
I-SATA2
P1-DIMM1B
P1-DIMM1A
P1-DIMM2B
P1-DIMM2A
P1-DIMM3B
P1-DIMM3A
CPU1
LES2
(*X8DT3 Models only)
I-SATA1
I-SATA0
1068E
Chassis Intrusion
Pin Defi nitions (JL1)
Pin# Defi nition 1 Intrusion Input 2 Ground
A. Fan 1
JPW1
A
Fan1
B. Fan 2 C. Fan 3
Fan7/ CPU1
SP1
JOH1
JD1
B
Fan2
LE1
1
JF1
1
Fan3
C
SI/O
Floppy
1
J5
LES1
SAS4~7
JL1
(*X8DT3 Models only)
SAS0~3
JPS2
JPS1
I
JSM2
JSM1
JWOL
Fan4
LSI
JPT1
JWD
D. Fan 4 E. Fan 5 F. Fan 6 G. Fan 7 (CPU1 Fan) H. Fan 8 (CPU2 Fan) I. Chassis Intrusion
2-21
Page 44
X8DT3/X8DTi/X8DT3-F/X8DTi-F/X8DT3-LN4F/X8DTi-LN4F User's Manual
Internal Speaker
The Internal Speaker, located at SP1, can be used to provide audible indica­tions for various beep codes. See the table on the right for pin defi nitions. Refer to the layout below for the loca­tions of the Internal Buzzer (SP1).
Power LED/Speaker
On the JD1 header, pins 1-3 are used for power LED indication, and pins 4-7 are for the speaker. See the table on the right for speaker pin defi nitions. Please note that the speaker con­nector pins (4-7) are for use with an external speaker. If you wish to use the onboard speaker, you should close pins 6-7 with a jumper.
Internal Buzzer (SP1)
Pin Defi nition
Pin# Defi nitions Pin 1 Pos. (+) Beep In Pin 2 Neg. (-) Alarm
Speaker
Speaker Connector
Pin Setting Defi nition Pins 6-7 Internal Speaker Pins 4-7 External Speaker
KB/MOUSE
USB 0/1
COM1
VGA
LAN1 LAN3
LAN2 LAN4
X8DT3/i Series
Fan8/ CPU2 FAN
LAN CTRL
LAN CTRL
(X8DT3/i-LN4F)
Battery
COM2
JPL1 JPL2
Fan6
Fan5
Dedicated LAN
(X8DT3/i-F/-LN4F only)
JLAN1
JLAN2
JI2C1
JI2C2
JPW2
P2-DIMM3A
P2-DIMM3B
P2-DIMM2A
P2-DIMM2B
P2-DIMM1A
P2-DIMM1B
Slot6 PCI-E 2.0x8
Slot5 PCI-E 2.0x8 in x16
Slot4 PCI-E 2.0 x16
Slot3
PCI 33 MHz
Slot2 PCI-E x4
J26
Slot1 PCI 33MHz
CPU2
SPEC
BIOS
JBT1
BMC/VGA
CTRL
D1
JPB
USB6/7
JPG1
J27J28
JUSB3
JPW3
J6
JPW1
Fan1
A. Internal Speaker (Buzz­er) B. PWR LED/Speaker
CPU1
Fan7/ CPU1
A
SP1
JOH1
B
SAS4~7
SAS0~3
JD1
Fan2
LE1
1
JF1
1
Fan3
SI/O
Floppy
1
J5
JSM2
JSM1
JWOL
JPS2
Fan4
USB4/5
JUSB2
ICH10R
South Bridge
USB3
P1-DIMM1B
P1-DIMM1A
P1-DIMM2B
P1-DIMM2A
P1-DIMM3B
P1-DIMM3A
Intel 5520
North Bridge
LES2
LES1
I-BUTTON
1068E
(*X8DT3 Models only)
JPT1
I-SATA1
I-SATA0
LSI
(*X8DT3 Models only)
JPS1
JWD
JL1
T-SGPIO1
T-SGPIO2
I-SATA5
I-SATA3
USB2
I-SATA4
I-SATA2
2-22
Page 45
Chapter 2: Installation
Wake-On-LAN
The Wake-On-LAN header is located at JWOL on the motherboard. You must also have a LAN card with a Wake-On-LAN connector and a cable to use this feature. See the table on the right for pin defi nitions.
Overheat LED/Fan Fail (JOH1)
The JOH1 header is used to connect an LED indi c ato r to p rov i de wa r ni ng s of chass is overhe ating or fa n failure. This LED will blink when a fan failure occu r s. Refe r to th e t abl e on r i ght f or pin defi nitions.
Wake-On-LAN
Pin Defi nitions
Pin# Defi nition 1 +5V Standby 2 Ground 3 Wake-up
Overheat LED
Pin Defi nitions
Pin# Defi nition 1 5vDC 2 OH Active
OH/Fan Fail LED
Pin Defi nitions
State Message Solid Overheat Blinking Fan Fail
KB/MOUSE
USB 0/1
COM1
VGA
LAN1 LAN3
LAN2 LAN4
X8DT3/i Series
Fan8/ CPU2 FAN
LAN CTRL
LAN
CTRL
(X8DT3/i-LN4F)
Battery
COM2
JPL1 JPL2
Fan6
Fan5
Dedicated LAN
(X8DT3/i-F/-LN4F only)
JLAN1
JLAN2
JI2C1 JI2C2
JPW2
P2-DIMM3A
P2-DIMM3B
P2-DIMM2A
P2-DIMM2B
P2-DIMM1A
P2-DIMM1B
Slot6 PCI-E 2.0x8
Slot5 PCI-E 2.0x8 in x16
Slot4 PCI-E 2.0 x16
Slot3
PCI 33 MHz
Slot2 PCI-E x4
J26
Slot1 PCI 33MHz
CPU2
SPEC
BMC/VGA
CTRL
D1
JPB
J27J28
JPW3
J6
JPW1
Fan1
A. Wake-On-LAN B. Overheat/Fan Fail LED
CPU1
Fan7/ CPU1
SP1
B
JOH1
SAS4~7
SAS0~3
JD1
Fan2
LE1
1
JF1
1
Fan3
SI/O
Floppy
1
J5
JSM2
JSM1
A
JWOL
JPS2
Fan4
P1-DIMM1B
P1-DIMM1A
P1-DIMM2B
P1-DIMM2A
P1-DIMM3B
P1-DIMM3A
Intel 5520
North Bridge
LES2
(*X8DT3 Models only)
I-SATA1
I-SATA0
1068E
LES1
LSI
(*X8DT3 Models only)
JPT1
JPS1
JWD
JL1
BIOS
JBT1
ICH10R
South Bridge
USB3
USB4/5
USB6/7
JPG1
JUSB3
JUSB2
T-SGPIO1
T-SGPIO2
I-BUTTON
I-SATA5
I-SATA3
USB2
I-SATA4
I-SATA2
2-23
Page 46
X8DT3/X8DTi/X8DT3-F/X8DTi-F/X8DT3-LN4F/X8DTi-LN4F User's Manual
T-SGPIO Headers
Two SGPIO (Serial-Link General Purpose Input/Output) headers (T-SGPIO-1/T-SGPIO-2) are located the motherboard. These headers support serial link interfaces for the onboard SATA and SAS connectors. See the table on the right for pin defi ni-
Pin# Defi nition Pin Defi nition 1NC 2 NC 3 Ground 4 Data
5 Load 6 Ground 7NC 8 NC
Note: NC= No Connections
T-SGPIO
Pin Defi nitions
tions. Refer to the board layout below for the location.
I-Button (Optional for X8DT3/-F/ LN4F only)
An onboard I-Button, located next to USB Ports 2~3, is an 1-wire computer chip enclosed in a durable stainless steel can. I-Button stores instruc­tions, provides electronic interface and allows HostRAID to operate with Mega-RAID fi rmware.
KB/MOUSE
USB 0/1
COM1
VGA
Fan8/ CPU2 FAN
LAN1 LAN3
LAN2 LAN4
LAN CTRL
LAN
CTRL
(X8DT3/i-LN4F)
X8DT3/i Series
Battery
COM2
JPL2
Fan5
Dedicated LAN
(X8DT3/i-F/-LN4F only)
JLAN1
JLAN2
JI2C1
JI2C2
JPL1
Fan6
Slot6 PCI-E 2.0x8
Slot5 PCI-E 2.0x8 in x16
Slot4 PCI-E 2.0 x16
Slot3
Slot2 PCI-E x4
Slot1 PCI 33MHz
JPW2
PCI 33 MHz
J26
P2-DIMM3A
P2-DIMM3B
P2-DIMM2A
P2-DIMM2B
P2-DIMM1A
P2-DIMM1B
JPW3
CPU2
SPEC
BIOS
JBT1
BMC/VGA
CTRL
D1
JPB
USB4/5
USB6/7
JPG1
J27J28
JUSB3
JUSB2
ICH10R
South Bridge
USB3
J6
A
B
T-SGPIO1
T-SGPIO2
I-SATA5
USB2
I-SATA4
I-SATA3
I-SATA2
P1-DIMM1B
P1-DIMM1A
P1-DIMM2B
P1-DIMM2A
P1-DIMM3B
P1-DIMM3A
Intel 5520
North Bridge
C
I-BUTTON
CPU1
LES2
(*X8DT3 Models only)
I-SATA1
I-SATA0
1068E
JPW1
Fan1
B. T-SGPIO-2 C. I-Button (Optional for
A. T-SGPIO-1
Fan7/ CPU1
SP1
JOH1
Fan2
LE1
JF1
Fan3
SI/O
Floppy
J5
LES1
SAS4~7
JL1
JSM2
(*X8DT3 Models only)
SAS0~3
JSM1
JWOL
JPS2
JPS1
Fan4
LSI
JPT1
JWD
X8DT3 models only)
JD1
1
1
1
2-24
Page 47
Chapter 2: Installation
Power SMB (I2C) Connector
Power System Management Bus
2
(I
C) Connector (J6) monitors power supply, fan and system temperatures. See the table on the right for pin defi nitions.
IPMB I2C SMB
A System Management Bus header for the IPMI slot is located at J5. Connect the appropriate cable here to use the IPMB I
2
C connection on
your system.
PWR SMB
Pin Defi nitions
Pin# Defi nition 1 Clock 2 Data
3 PWR Fail 4 Ground 5 +3.3V
SMB Header
Pin Defi nitions
Pin# Defi nition 1 Data 2 Ground 3 Clock 4 No Connection
KB/MOUSE
USB 0/1
COM1
VGA
LAN1 LAN3
LAN2 LAN4
(X8DT3/i-LN4F)
X8DT3/i Series
COM2
LAN CTRL
LAN
CTRL
Dedicated LAN
(X8DT3/i-F/-LN4F only)
Fan8/ CPU2 FAN
JLAN1
JLAN2
Battery
JPL1 JPL2
Fan5
JI2C1
JI2C2
Fan6
Slot6 PCI-E 2.0x8
Slot5 PCI-E 2.0x8 in x16
Slot4 PCI-E 2.0 x16
Slot3
Slot2 PCI-E x4
Slot1 PCI 33MHz
JPW2
PCI 33 MHz
P2-DIMM3A
P2-DIMM3B
P2-DIMM2A
P2-DIMM2B
P2-DIMM1A
P2-DIMM1B
CPU2
SPEC
BMC/VGA
CTRL
J26
JPB
J6
ICH10R
South Bridge
USB3
A
CPU1
P1-DIMM1B
P1-DIMM1A
P1-DIMM2B
P1-DIMM2A
P1-DIMM3B
P1-DIMM3A
Intel 5520
North Bridge
LES2
T-SGPIO1
T-SGPIO2
I-BUTTON
(*X8DT3 Models only)
I-SATA3
I-SATA2
I-SATA1
I-SATA0
I-SATA5
USB2
I-SATA4
1068E
JPW1
Fan1
Fan7/ CPU1
SP1
JOH1
JD1
Fan2
LE1
1
JF1
1
Fan3
SI/O
Floppy
B
1
J5
LES1
SAS4~7
JL1
JSM2
(*X8DT3 Models only)
SAS0~3
JSM1
JWOL
JPS2
JPS1
Fan4
LSI
JPT1
JWD
JPW3
BIOS
JBT1
D1
USB4/5
USB6/7
JPG1
J27J28
JUSB3
JUSB2
A. PWR SMB B. IPMB SMB
2-25
Page 48
X8DT3/X8DTi/X8DT3-F/X8DTi-F/X8DT3-LN4F/X8DTi-LN4F User's Manual
Connector
Pins
Jumper
Cap
Setting
2-7 Jumper Settings
Explanation of Jumpers
To modify the operation of the mother­board, jumpers can be used to choose between optional settings. Jumpers create shorts between two pins to change the function of the connector. Pin 1 is identifi ed with a square solder pad on the printed circuit board. See the motherboard layout pages for jumper locations.
Note: On two pin jumpers, "Clos ed " me ans t he j ump er i s on and "O pen" mea ns the ju mper i s off t he pins.
GLAN Enable/Disable
Use JPL1 to enable or dis able the G LA N Ports 1 & 2. Use JPL2 to enable or disable the GLAN Ports 3 & 4 on the X8DT3/i­LN4F. See the tables on the right for jumper settings. The default setting is
Enabled.
3 2 1
3 2 1
Pin 1-2 short
GLAN 1 & 2 Enable
Jumper Settings (JPL1)
Pin# Defi nition 1-2 Enabled (default) 2-3 Disabled
GLAN 3 & 4 Enable
Jumper Settings (JPL2)
Pin# Defi nition 1-2 Enabled (default) 2-3 Disabled
KB/MOUSE
USB 0/1
COM1
VGA
LAN1 LAN3
LAN2 LAN4
X8DT3/i Series
Fan8/ CPU2 FAN
LAN CTRL
LAN CTRL
(X8DT3/i-LN4F)
Battery
COM2
JPL1 JPL2
Fan6
Fan5
Dedicated LAN
(X8DT3/i-F/-LN4F only)
JLAN1
JLAN2
JI2C1
JI2C2
A
B
JPW2
P2-DIMM3A
P2-DIMM3B
P2-DIMM2A
P2-DIMM2B
P2-DIMM1A
P2-DIMM1B
Slot6 PCI-E 2.0x8
Slot5 PCI-E 2.0x8 in x16
Slot4 PCI-E 2.0 x16
Slot3
PCI 33 MHz
Slot2 PCI-E x4
J26
Slot1 PCI 33MHz
CPU2
SPEC
BIOS
JBT1
BMC/VGA
CTRL
D1
JPB
USB6/7
JPG1
J27J28
JUSB3
A. GLAN 1 &2 Enable B. GLAN 3 & 4 Enable
X8DT3/i - LN4F on ly)
(For
JUSB2
ICH10R
South Bridge
USB3
J6
CPU1
P1-DIMM1B
P1-DIMM1A
P1-DIMM2B
P1-DIMM2A
P1-DIMM3B
P1-DIMM3A
Intel 5520
North Bridge
LES2
T-SGPIO1
T-SGPIO2
I-BUTTON
(*X8DT3 Models only)
I-SATA3
I-SATA2
I-SATA1
I-SATA0
I-SATA5
USB2
I-SATA4
1068E
JPT1
JPW1
Fan1
Fan7/ CPU1
SP1
JOH1
JD1
Fan2
LE1
1
JF1
1
Fan3
SI/O
Floppy
1
J5
LES1
SAS4~7
JL1
JSM2
(*X8DT3 Models only)
SAS0~3
JSM1
JWOL
JPS2
JPS1
Fan4
LSI
JWD
JPW3
USB4/5
2-26
Page 49
Chapter 2: Installation
CMOS Clear
JBT1 is used to clear CMOS. Instead of pins, this "jumper " consists of c ontact pads to prevent t he accident al clearin g of CMOS. To clear CMOS , use a metal objec t such as a sma ll screwdr iver to touc h both pad s at the same t ime to shor t the co nnec ti on. A lways rem ove the AC p ower c ord f rom t he syste m befo re cl ear­ing CMOS.
Note: For an ATX power supply, you must completely shut down the sys­tem, remove the AC power cord and then short JBT1 to clear CMOS.
Watch Dog Enable/Disable
Watch Dog (JWD) is a syste m monitor th at can reb oot t he sys tem w hen a s of tware ap ­plicat ion han gs. Clo se Pins 1-2 to res et the system if an app lication ha ngs. Close Pins 2-3 to generate a non-maskable interrupt signal for the application that hangs. See the table on the right for jumper settings. Watch Dog must also be enabled in the BIOS.
KB/MOUSE
USB 0/1
COM1
VGA
LAN1 LAN3
LAN2 LAN4
LAN
CTRL
LAN CTRL
(X8DT3/i-LN4F)
X8DT3/i Series
Battery
COM2
Fan5
Dedicated LAN
(X8DT3/i-F/-LN4F only)
Fan8/ CPU2 FAN
JLAN1
JLAN2
JI2C2
JPL1
JPL2
Fan6
JI2C1
JPW2
P2-DIMM3A
P2-DIMM3B
P2-DIMM2A
P2-DIMM2B
P2-DIMM1A
P2-DIMM1B
Slot6 PCI-E 2.0x8
Slot5 PCI-E 2.0x8 in x16
Slot4 PCI-E 2.0 x16
Slot3
PCI 33 MHz
Slot2 PCI-E x4
J26
Slot1 PCI 33MHz
JPW3
CPU2
SPEC
BIOS
JBT1
BMC/VGA
CTRL
D1
JPB
USB4/5
USB6/7
JPG1
J27J28
JUSB3
J6
CPU1
P1-DIMM1B
P1-DIMM1A
P1-DIMM2B
P1-DIMM2A
P1-DIMM3B
P1-DIMM3A
Intel 5520
North Bridge
A
ICH10R
South Bridge
USB3
T-SGPIO1
T-SGPIO2
I-BUTTON
(*X8DT3 Models only)
I-SATA3
I-SATA1
-
-
I-SATA5
USB2
-
Watch Dog
Jumper Settings (JWD)
Jumper Setting Defi nition Pins 1-2 Reset
(default) Pins 2-3 NMI Open Disabled
A. Clear CMOS
JPW1
Fan1
Fan7/ CPU1
SP1
JOH1
JD1
Fan2
LE1
1
JF1
1
Fan3
SI/O
Floppy
1
LES2
1068E
JPT1
B
J5
LES1
SAS4~7
JL1
JSM2
(*X8DT3 Models only)
SAS0~3
JSM1
JWOL
JPS2
JPS1
Fan4
LSI
JWD
B. Watch Dog Enable
2-27
Page 50
X8DT3/X8DTi/X8DT3-F/X8DTi-F/X8DT3-LN4F/X8DTi-LN4F User's Manual
I2C Bus to PCI-Exp. Slots
Jumpers JI
2
C1 and JI2C2 allow you to
connect the System Management Bus
2
(I
C) to PCI-Express slots. The default
setting is Open to disable the connec-
Jumper Setting Defi nition 1-2 Enabled 2-3 Disabled (Default)
I2C to PCI-Exp
Jumper Settings
tion. See the table on the right for jumper settings.
VGA Enable
Jumper JPG1 allows the user to enable the onboard VGA connector. The default setting is 1-2 to enable the connection. See the table on the right for jumper settings.
KB/MOUSE
USB 0/1
COM1
VGA
LAN1 LAN3
LAN2 LAN4
LAN CTRL
LAN CTRL
(X8DT3/i-LN4F)
X8DT3/i Series
Battery
COM2
Fan5
Dedicated LAN
(X8DT3/i-F/-LN4F only)
Fan8/ CPU2 FAN
JLAN1
JLAN2
A
JI2C1
JI2C2
B
JPL1 JPL2
Fan6
Slot6 PCI-E 2.0x8
Slot5 PCI-E 2.0x8 in x16
Slot3
Slot2 PCI-E x4
Slot1 PCI 33MHz
JPW2
P2-DIMM3A
P2-DIMM3B
P2-DIMM2A
P2-DIMM2B
P2-DIMM1A
P2-DIMM1B
Slot4 PCI-E 2.0 x16
PCI 33 MHz
J26
JPW3
CPU2
SPEC
BIOS
JBT1
BMC/VGA
CTRL
C
D1
JPB
USB4/5
USB6/7
JPG1
J27J28
JUSB3
ICH10R
South Bridge
USB3
J6
T-SGPIO1
T-SGPIO2
I-SATA5
I-SATA3
USB2
-
-
P1-DIMM1B
P1-DIMM1A
P1-DIMM2B
P1-DIMM2A
P1-DIMM3B
P1-DIMM3A
Intel 5520
North Bridge
I-BUTTON
CPU1
LES2
(*X8DT3 Models only)
I-SATA1
-
VGA Enable
Jumper Settings
Jumper Setting Defi nition 1-2 Enabled 2-3 Disabled (Default)
JPW1
Fan1
A. JI B. JI
C. VGA Enable
JD1
1
1
1
1068E
JPT1
Fan7/ CPU1
SP1
JOH1
Fan2
LE1
JF1
Fan3
SI/O
Floppy
J5
LES1
SAS4~7
JL1
JSM2
(*X8DT3 Models only)
SAS0~3
JSM1
JWOL
JPS2
JPS1
Fan4
LSI
JWD
2
2
C1 C2
2-28
Page 51
Chapter 2: Installation
SAS Enable/Disable (X8DT3/ X8DT3-F/X8DT3-LN4F only)
Jumper JPS1 allows you to enable or disable the onboard SAS connections. The default setting is Pins 1-2 to enable the connection. See the table on the right for jumper settings.
SAS RAID Select (X8DT3/X8DT3-F/ X8DT3-LN4F only)
Jumper JPS2 allows you to select RAID Confi guration settings for the onboard SAS connections. See the table on the right for jumper settings.
Note: For more information on LSI SAS RAID confi guration, please refer to the LSI MegaRAID User's Guide posted on our website @ http://www. supermicro.com/support/manuals/.
SAS Enable
Jumper Settings
Jumper Setting Defi nition 1-2 SAS Enabled (Default) 2-3 SAS Disabled
SAS RAID Confi g. Select
Jumper Settings
Jumper Setting Defi nition Open Integrated Target Mode (IT) Closed Software RAID (SR) (Default)
KB/MOUSE
USB 0/1
COM1
VGA
LAN1 LAN3
LAN2 LAN4
X8DT3/i Series
Fan8/ CPU2 FAN
LAN CTRL
LAN
CTRL
(X8DT3/i-LN4F)
Battery
COM2
JPL1 JPL2
Fan6
Fan5
Dedicated LAN
(X8DT3/i-F/-LN4F only)
JLAN1
JLAN2
JI2C1 JI2C2
JPW2
P2-DIMM3A
P2-DIMM3B
P2-DIMM2A
P2-DIMM2B
P2-DIMM1A
P2-DIMM1B
Slot6 PCI-E 2.0x8
Slot5 PCI-E 2.0x8 in x16
Slot4 PCI-E 2.0 x16
Slot3
PCI 33 MHz
Slot2 PCI-E x4
J26
Slot1 PCI 33MHz
CPU2
SPEC
BMC/VGA
CTRL
D1
JPB
J27J28
JPW3
J6
JPW1
Fan1
A. SAS Enable B. SAS RAID Confi g.
Select
CPU1
Fan7/ CPU1
SP1
JOH1
SAS4~7
SAS0~3
JD1
Fan2
LE1
1
JF1
1
Fan3
SI/O
Floppy
1
J5
JSM2
JSM1
B
JWOL
JPS2
Fan4
P1-DIMM1B
P1-DIMM1A
P1-DIMM2B
P1-DIMM2A
P1-DIMM3B
P1-DIMM3A
Intel 5520
North Bridge
LES2
(*X8DT3 Models only)
I-SATA1
-
1068E
LES1
LSI
(*X8DT3 Models only)
JPT1
A
JPS1
JWD
JL1
BIOS
JBT1
ICH10R
South Bridge
USB3
USB4/5
USB6/7
JPG1
JUSB3
T-SGPIO1
T-SGPIO2
I-BUTTON
I-SATA5
I-SATA3
USB2
-
-
2-29
Page 52
X8DT3/X8DTi/X8DT3-F/X8DTi-F/X8DT3-LN4F/X8DTi-LN4F User's Manual
2-8 Onboard LED Indicators
GLAN LEDs
Two LAN ports (LAN 1/LAN 2) are located on the IO Backplane of the motherboard. In addition, LAN3/LAN4 are located on the X8DT3/i-LN4F. Each Ethernet LAN port has two LEDs. The yellow LED indicates activ ity, while the Li nk LED may be gree n, amber or off to indicate the speed of the connections. See the tables at right for more information.
IPMI Dedicated LAN LEDs (X8DT3/i-F/­LN4F Only)
In addition to LAN 1/LAN 2, an IPMI Dedicat­ed LAN is also located on the IO Backplane of the X8DT3/i-F/-LN4F. The amber LED on the ri ght indica tes activi ty, while the gre en LED on the l eft indic ates the spee d of the connection. See the tables at right for more information.
Activity LED
Link LED
Rear View (when facing the
rear side of the chassis)
LAN 1/LAN 2 Activity LED (Left)
Color Status Defi nition Yellow Flashing Active
LAN 1/LAN 2 Link LED (Right)
LED Color Defi nition Off No Connection or 10 Mbps Green 100 Mbps Amber 1 Gbps
Link LED
Color Status Defi nition Link (Left) Green: Solid 100 Mbps Activity (Right) Amber: Blinking Active
LED State
LED State
IPMI LAN (F models only)
Activity LED
IPMI LAN Link LED (Left) &
Activity LED (Right)
A
KB/MOUSE
USB 0/1
COM1
VGA
LAN1 LAN3
LAN2 LAN4
X8DT3/i Series
Fan8/ CPU2 FAN
LAN CTRL
LAN CTRL
(X8DT3/i-LN4F)
Battery
COM2
JPL1 JPL2
Fan6
Fan5
C
Dedicated LAN
(X8DT3/i-F/-LN4F only)
JLAN1
B
JLAN2
JI2C1 JI2C2
JPW2
P2-DIMM3A
P2-DIMM3B
P2-DIMM2A
P2-DIMM2B
P2-DIMM1A
P2-DIMM1B
Slot6 PCI-E 2.0x8
Slot5 PCI-E 2.0x8 in x16
Slot4 PCI-E 2.0 x16
Slot3
PCI 33 MHz
Slot2 PCI-E x4
J26
Slot1 PCI 33MHz
CPU2
SPEC
BMC/VGA
CTRL
JPB
ICH10R
South Bridge
USB3
J6
CPU1
P1-DIMM1B
P1-DIMM1A
P1-DIMM2B
P1-DIMM2A
P1-DIMM3B
P1-DIMM3A
Intel 5520
North Bridge
LES2
T-SGPIO1
T-SGPIO2
I-BUTTON
(*X8DT3 Models only)
I-SATA3
I-SATA1
-
-
I-SATA5
USB2
-
1068E
JPT1
JPW1
Fan1
SP1
LE1
SI/O
Floppy
J5
LES1
SAS4~7
JL1
JSM2
(*X8DT3 Models only)
SAS0~3
JSM1
JWOL
JPS2
JPS1
Fan4
LSI
JWD
JPW3
BIOS
JBT1
D1
USB4/5
USB6/7
JPG1
J27J28
JUSB3
A. LAN1/2 LEDs B. LAN3/4 LEDs (X8DT3/i­LN4) B. Dedicated LAN LEDs
Fan7/ CPU1
(X8DT3/i-F/-LN4F)
JOH1
JD1
Fan2
1
JF1
1
Fan3
1
2-30
Page 53
SAS Heartbeat/Activity LED Indicators
Chapter 2: Installation
Two Onboard SAS LED are located on the motherboard. LES1 is SAS Heart­beat LED, and LES2 is SAS Activity LED. When LES1 is blinking, SAS con­nections function normally. When this LES2 is blinking, SAS connections are active. See the tables at right for more information.
BMC Heartbeat LED
A BMC He artbeat LED is l ocated at D1 on the motherboard. When D1 is blinking, BMC fu nctions nor mally. See the tab les at right fo r more info rmati on.
Onboard SAS LED Indicators
(LES1/LES2) Settings
LED Color Defi nition LES1 Blinking: SAS: Normal LES2 Blinking: SAS: Active
BMC Heartbeat LED Indicators
(D1) Settings
LED Defi nition D1 Blinking: BMC: Normal
KB/MOUSE
USB 0/1
COM1
VGA
LAN1 LAN3
LAN2 LAN4
X8DT3/i Series
Fan8/ CPU2 FAN
LAN CTRL
LAN
CTRL
(X8DT3/i-LN4F)
Battery
COM2
JPL1 JPL2
Fan6
Fan5
Dedicated LAN
(X8DT3/i-F/-LN4F only)
JLAN1
JLAN2
JI2C1 JI2C2
JPW2
P2-DIMM3A
P2-DIMM3B
P2-DIMM2A
P2-DIMM2B
P2-DIMM1A
P2-DIMM1B
Slot6 PCI-E 2.0x8
Slot5 PCI-E 2.0x8 in x16
Slot4 PCI-E 2.0 x16
Slot3
PCI 33 MHz
Slot2 PCI-E x4
J26
Slot1 PCI 33MHz
CPU2
SPEC
BMC/VGA
CTRL
C
D1
JPB
J27J28
ICH10R
South Bridge
USB3
J6
CPU1
P1-DIMM1B
P1-DIMM1A
P1-DIMM2B
P1-DIMM2A
P1-DIMM3B
P1-DIMM3A
Intel 5520
North Bridge
B
LES2
T-SGPIO1
T-SGPIO2
I-BUTTON
(*X8DT3 Models only)
I-SATA3
I-SATA1
-
-
I-SATA5
USB2
-
1068E
JPW1
Fan1
A. GLAN Port LEDs B. Onboard Power LED
Fan7/ CPU1
SP1
JOH1
JD1
Fan2
LE1
1
JF1
1
Fan3
SI/O
J5
SAS4~7
JSM2
(*X8DT3 Models only)
SAS0~3
JSM1
JWOL
JPS2
JPS1
Floppy
1
Fan4
A
LES1
LSI
JPT1
JWD
JL1
JPW3
BIOS
JBT1
USB4/5
USB6/7
JPG1
JUSB3
2-31
Page 54
X8DT3/X8DTi/X8DT3-F/X8DTi-F/X8DT3-LN4F/X8DTi-LN4F User's Manual
Onboard Power LED
An Onboard Power LED is located at LE1 on the motherboard. When this LED is lit, the system is on. Be sure to turn off the system and unplug the power cord before
Onboard PWR LED (LE1)
Settings
LED Color Defi nition Off System Off (PWR cable
not connected)
Green System Power On
removing or installing components. See the tabl es at rig ht for mor e infor mation.
KB/MOUSE
USB 0/1
COM1
VGA
LAN1 LAN3
LAN2 LAN4
X8DT3/i Series
Fan8/ CPU2 FAN
LAN CTRL
LAN CTRL
(X8DT3/i-LN4F)
Battery
COM2
JPL1 JPL2
Fan6
Fan5
Dedicated LAN
(X8DT3/i-F/-LN4F only)
JLAN1
JLAN2
JI2C1
JI2C2
JPW2
P2-DIMM3A
P2-DIMM3B
P2-DIMM2A
P2-DIMM2B
P2-DIMM1A
P2-DIMM1B
Slot6 PCI-E 2.0x8
Slot5 PCI-E 2.0x8 in x16
Slot4 PCI-E 2.0 x16
Slot3
PCI 33 MHz
Slot2 PCI-E x4
J26
Slot1 PCI 33MHz
CPU2
SPEC
BIOS
JBT1
BMC/VGA
CTRL
D1
JPB
USB6/7
JPG1
J27J28
JUSB3
ICH10R
South Bridge
USB3
J6
CPU1
P1-DIMM1B
P1-DIMM1A
P1-DIMM2B
P1-DIMM2A
P1-DIMM3B
P1-DIMM3A
Intel 5520
North Bridge
LES2
T-SGPIO1
T-SGPIO2
I-BUTTON
(*X8DT3 Models only)
I-SATA3
I-SATA1
-
-
I-SATA5
USB2
-
1068E
JPT1
JPW1
Fan1
Fan7/ CPU1
SP1
JOH1
JD1
Fan2
LE1
A
1
JF1
1
Fan3
SI/O
Floppy
1
J5
LES1
SAS4~7
JL1
JSM2
(*X8DT3 Models only)
SAS0~3
JSM1
JWOL
JPS2
JPS1
Fan4
LSI
JWD
A. Onboard Power LED
JPW3
USB4/5
2-32
Page 55
Chapter 2: Installation
2-9 Floppy Drive, Serial ATA and SAS Connections
Note the fo llowi ng when c onne cting t he fl oppy and hard disk drive cables:
The fl oppy disk drive cable has seven twisted wires.
•
A red mark on a wire typically designates the location of pin 1.•
A single fl oppy disk drive ribbon cable has 34 wires and two connectors to • provide for two fl oppy disk drives. The connector with twisted wires always connects to drive A, and the connector that does not have twisted wires always connects to drive B.
Floppy Drive Connector
Pin Defi nitions
Pin# Defi nition Pin # Defi nition 1 Ground 2 FDHDIN 3 Ground 4 Reserved 5 Key 6 FDEDIN
Floppy Connector
The fl oppy connector is located next to the Super I/O chip on the mother­board. See the table on the right for pin defi nitions.
7 Ground 8 Index 9 Ground 10 Motor Enable 11 Ground 12 Drive Select B 13 Ground 14 Drive Select B 15 Ground 16 Motor Enable 17 Ground 18 DIR 19 Ground 20 STEP 21 Ground 22 Write Data 23 Ground 24 Write Gate 25 Ground 26 Track 00 27 Ground 28 Write Protect 29 Ground 30 Read Data 31 Ground 32 Side 1 Select 33 Ground 34 Diskette
KB/MOUSE
Fan6
USB 0/1
COM1
VGA
LAN1 LAN3
LAN2 LAN4
LAN CTRL
LAN
CTRL
(X8DT3/i-LN4F)
X8DT3/i Series
Battery
COM2
Fan5
Dedicated LAN
(X8DT3/i-F/-LN4F only)
Fan8/ CPU2 FAN
JLAN1
JLAN2
JPL1 JPL2
JI2C1 JI2C2
JPW2
P2-DIMM3A
P2-DIMM3B
P2-DIMM2A
P2-DIMM2B
P2-DIMM1A
P2-DIMM1B
Slot6 PCI-E 2.0x8
Slot5 PCI-E 2.0x8 in x16
Slot4 PCI-E 2.0 x16
Slot3
PCI 33 MHz
Slot2 PCI-E x4
J26
Slot1 PCI 33MHz
JPW3
CPU2
SPEC
BIOS
JBT1
BMC/VGA
CTRL
D1
JPB
USB4/5
USB6/7
JPG1
J27J28
JUSB3
ICH10R
South Bridge
USB3
J6
CPU1
P1-DIMM1B
P1-DIMM1A
P1-DIMM2B
P1-DIMM2A
P1-DIMM3B
P1-DIMM3A
Intel 5520
North Bridge
T-SGPIO1
T-SGPIO2
I-BUTTON
I-SATA1
I-SATA5
I-SATA3
USB2
-
-
-
LES2
LES1
LSI
1068E
(*X8DT3 Models only)
JPT1
JWD
JL1
JPW1
SP1
SI/O
J5
SAS4~7
JSM2
(*X8DT3 Models only)
SAS0~3
JSM1
JWOL
JPS2
JPS1
Fan1
Fan7/ CPU1
JOH1
JD1
Fan2
LE1
1
JF1
1
Fan3
A
Floppy
1
Fan4
A. Floppy
2-33
Page 56
X8DT3/X8DTi/X8DT3-F/X8DTi-F/X8DT3-LN4F/X8DTi-LN4F User's Manual
G
F
E
D
H
Serial ATA Ports
Six Serial ATA Ports (I-SATA0~I -SA­TA 5) are lo cate d at JS1~JS6 on t he motherboard. These ports provide serial-link signal connections, which are faster than the connections of Parallel ATA. See the table on the right fo r pin defi nitions.
SAS Ports (X8DT3/X8DT3-F/ X8DT3-LN4F only)
SAS Ports 0~3, 4~7 , located at JSM1 / JSM2 , p r ov i d e S e rial- Attache d SCSI connections on the X8DT3/X8DT3-F/ X8DT3-LN4F. See the layout below for SAS po r t loc ations .
Serial ATA
Pin Defi nitions
Pin# Defi nition 1 Ground 2 TX_P 3 TX_N 4 Ground 5 RX_N 6 RX_P 7 Ground
KB/MOUSE
USB 0/1
COM1
VGA
Fan8/ CPU2 FAN
LAN1 LAN3
LAN2 LAN4
LAN CTRL
LAN CTRL
(X8DT3/i-LN4F)
X8DT3/i Series
Battery
COM2
JPL1 JPL2
Fan6
Fan5
Dedicated LAN
(X8DT3/i-F/-LN4F only)
JLAN1
JLAN2
JI2C1
JI2C2
Note 1: For more information on SATA HostRAID confi guration, please refer to the Intel SATA HostRAID User's Guide posted on our website @ http://www.supermicro.com/support/manuals/.
Note 2: For more information on LSI SAS RAID confi guration, please refer to the LSI MegaRAID User's Guide posted on our website @ http:// www.supermicro.com/support/manuals/.
JPW2
P2-DIMM3A
P2-DIMM3B
P2-DIMM2A
P2-DIMM2B
P2-DIMM1A
P2-DIMM1B
Slot6 PCI-E 2.0x8
Slot5 PCI-E 2.0x8 in x16
Slot4 PCI-E 2.0 x16
Slot3
PCI 33 MHz
Slot2 PCI-E x4
J26
Slot1 PCI 33MHz
ICH10R
South Bridge
USB3
J6
CPU1
P1-DIMM1B
P1-DIMM1A
P1-DIMM2B
P1-DIMM2A
P1-DIMM3B
P1-DIMM3A
Intel 5520
North Bridge
LES2
T-SGPIO1
T-SGPIO2
I-BUTTON
(*X8DT3 Models only)
B
I-SATA3
I-SATA1
-
-
A
C
I-SATA5
USB2
-
1068E
JPT1
JPW1
Fan1
Fan7/ CPU1
SP1
JOH1
Fan2
LE1
JF1
Fan3
SI/O
Floppy
J5
LES1
SAS4~7
JL1
JSM2
(*X8DT3 Models only)
SAS0~3
JSM1
JWOL
JPS2
JPS1
Fan4
LSI
JWD
JPW3
CPU2
SPEC
BIOS
JBT1
BMC/VGA
CTRL
D1
JPB
USB4/5
USB6/7
JPG1
J27J28
JUSB3
A. I-SATA0 B. I-SATA1 C. I-SATA2 D. I-SATA3 E. I-SATA4 F. I-SATA5
JD1
G. SAS 0~3 (X8DT3/-F/-LN4F only)
1
H. SAS 4~7 (X8DT3/-F/-LN4F
1
only)
1
2-34
Page 57
Chapter 3: Troubleshooting
Chapter 3
Troubleshooting
3-1 Troubleshooting Procedures
Use the following procedures to troubleshoot your system. If you have followed all of the procedures below and still need assistance, refer to the ‘Technical Support Procedures’ and/or ‘Returning Merchandise for Service’ section(s) in this chapter. Note: Always disconnect the power cord before adding, changing or installing any hardware components.
Before Power On
Make sure that there are no short circuits between the motherboard and 1. chassis.
Disconnect all ribbon/wire cables from the motherboard, including those for 2. the keyboard and mouse.
Remove all add-on cards.3.
Install CPU 1 fi rst (making sure it is fully seated) and connect the chassis 4. speaker and the power LED to the motherboard. (Check all jumper settings as well.)
No Power
Make sure that no short circuits between the motherboard and the chassis.1.
Make sure that all jumpers are set to their default positions.2.
Check that the 115V/230V switch on the power supply is properly set.3.
Turn the power switch on and off to test the system.4.
The battery on your motherboard may be old. Check to verify that it still sup-5. plies ~3VDC. If it does not, replace it with a new one.
3-1
Page 58
X8DT3/X8DTi/X8DT3-F/X8DTi-F/X8DT3-LN4F/X8DTi-LN4F User's Manual
No Video
If the power is on but you have no video, remove all the add-on cards and 1. cables.
Use the speaker to determine if any beep codes exist. Refer to Appendix A 2. for details on beep codes.
Losing the System’s Setup Confi guration
Make sure that you are using a high quality power supply. A poor quality 1. power supply may cause the system to lose the CMOS setup information. Refer to Section 1-6 for details on recommended power supplies.
The battery on your motherboard may be old. Check to verify that it still sup-2. plies ~3VDC. If it does not, replace it with a new one.
If the above steps do not fi x the Setup Confi guration problem, contact your 3. vendor for repairs.
Memory Errors
When a No_Memory_Beep_Code is issued by the system, check the following:
Make sure that the DIMM modules are properly and fully installed. 1.
Check if different speeds of DIMMs have been installed. It is strongly recom-2. mended to use the same RAM speed for all DIMMs in the system.
Make sure you are using the correct type of DDR3 Registered ECC 1333 3. MHz/1066 MHz/800 MHz SDRAM (recommended by the manufacturer.)
Check for bad DIMM modules or slots by swapping a single module between 4. all memory slots and check the results.
Make sure that all memory modules are fully seated in their slots. Make sure 5. to follow the instructions given in Section 2-4 in Chapter 2.
Check the position of the 115V/230V switch on the power supply. 6.
Please follow the instructions given in the DIMM Population Tables listed on 7. Pages 2-7 and 2-8 to install your memory modules.
3-2
Page 59
Chapter 3: Troubleshooting
3-2 Technical Support Procedures
Before contacting Technical Support, please take the following steps. Also, please note that as a motherboard manufacturer, Supermicro does not sell directly to end­users, so it is best to fi rst check with your distributor or reseller for troubleshooting services. They should know of any possible problem(s) with the specifi c system confi guration that was sold to you.
Please go through the ‘Troubleshooting Procedures’ and 'Frequently Asked 1. Question' (FAQ) sections in this chapter or see the FAQs on our web site (
http://www.supermicro.com/support/faqs/) before contacting Technical Sup-
port.
BIOS upgrades can be downloaded from our web site at 2.
supermicro.com/support/bios/
If you still cannot resolve the problem, include the following information when 3. contacting Supermicro for technical support:
Motherboard model and PCB revision number
•
BIOS release date/version (this can be seen on the initial display when your • system fi rst boots up)
System confi guration
•
An example of a Technical Support form is on our web site at • (http://www.
supermicro.com/support/contact.cfm).
Distributors: For immediate assistance, please have your account number ready
•
when placing a call to our technical support department. We can be reached by e-mail at [email protected] or by fax at: (408) 503-8000, option 2.
).
(http://www.
3-3 Frequently Asked Questions
Que sti on: Wh at a re th e var iou s t ype s of m emo r y th at my mo th er boa rd c an support?
Answer: The X8DT3/X8DTi/X8DT3-F/X8DTi-F/X8DT3-LN4F/X8DTi-LN4F has 12
240-pin DIMM slots that support DDR3 Registered ECC 1333 MHz/1066 MHz/800 MHz SDRAM modules. It is strongly recommended that you do not mix memory modules of different speeds and sizes. Please follow all memory installation instruc­tions given on Section 2-4 in Chapter 2.
3-3
Page 60
X8DT3/X8DTi/X8DT3-F/X8DTi-F/X8DT3-LN4F/X8DTi-LN4F User's Manual
Que stio n: How do I u pda te my BI OS? Answer: It is recommended that you do not upgrade your BIOS if you are not
experiencing any problems with your system. Updated BIOS fi les are located on our web site at warning message and the information on how to update your BIOS on our web site. Select your motherboard model and download the BIOS fi le to your computer. Also, check the current BIOS revision and make sure that it is newer than your BIOS before downloading. You can choose from the zip fi le and the .exe fi le. If you choose the zip BIOS fi le, please unzip the BIOS fi le onto a bootable USB device. Run the batch fi le using the format fl ash.bat fi lename.rom from your bootable USB device to fl ash the BIOS. Then, your system will automatically reboot. Please note that this process may take a few minutes to complete. Do not be concerned if the screen is paused for a few minutes.
http://www.supermicro.com/support/bios/. Please check our BIOS
Warning: Do not shut down or reset the system while updating the BIOS
to prevent possible system boot failure!)
Note: The SPI BIOS chip used on this motherboard cannot be removed.
Send your motherboard back to our RMA Department at Supermicro for repair.
Question: What's on the CD that came with my motherboard? Answer: The supplied CD has drivers and programs that are needed for your sys-
tem. Please r eview t h e C D and i ns t al l th e ap pl ications you nee d. A p p lications on the CD inc lude c hipset d river s for th e Wind ows OS, se cur ity an d audio dr iver s.
3-4 Returning Merchandise for Service
A receipt or copy of your invoice marked with the date of purchase is required be­fore any warranty service will be rendered. You can obtain service by calling your vendor for a Returned Merchandise Authorization (RMA) number. When returning to the manufacturer, the RMA number should be prominently displayed on the outside of the shipping carton, and mailed prepaid or hand-carried. Shipping and handling charges will be applied for all orders that must be mailed when service is complete.
For faster service, You can also request a RMA authorization online (http://www. supermicro.com/support/rma/).
This warranty only covers normal consumer use and does not cover damages in­curred in shipping or from failure due to the alternation, misuse, abuse or improper maintenance of products.
During the warranty period, contact your distributor fi rst for any product problems.
3-4
Page 61
Chapter 4: AMI BIOS
Chapter 4
BIOS
4-1 Introduction
This chapter describes the AMI BIOS Setup Utility for the X8DT3/X8DTi/X8DT3­LN4/X8DTi-LN4. The AMI ROM BIOS is stored in a Flash EEPROM and can be easily updated. This chapter describes the basic navigation of the AMI BIOS Setup Utility setup screens.
Starting BIOS Setup Utility
To enter the AMI BIOS Setup Utility screens, press the <Delete> key while the system is booting up.
Note: In most cases, the <Delete> key is used to invoke the AMI BIOS setup screen. There are a few cases when other keys are used, such as <F1>, <F2>, etc.
Each main BIOS menu option is described in this manual. The Main BIOS setup menu screen has two main frames. The left frame displays all the options that can be confi gured. Grayed-out options cannot be confi gured. Options in blue can be confi gured by the user. The right frame displays the key legend. Above the key legend is an area reserved for a text message. When an option is selected in the left frame, it is highlighted in white. Often a text message will accompany it. (Note: the AMI BIOS has default text messages built in. Supermicro retains the option to include, omit, or change any of these text messages.)
The AMI BIOS Setup Utility uses a key-based navigation system called "hot keys". Most of the AMI BIOS setup utility "hot keys" can be used at any time during the setup navigation process. These keys include <F1>, <F10>, <Enter>, <ESC>, ar­row keys, etc.
Note: Options printed in Bold are default settings.
How To Change the Confi guration Data
The confi guration data that determines the system parameters may be changed by entering the AMI BIOS Setup utility. This Setup utility can be accessed by pressing <Del> at the appropriate time during system boot.
4-1
Page 62
X8DT3/X8DTi/X8DT3-LN4/X8DTi-LN4 User’s Manual
Starting the Setup Utility
Normally, the only visible Power-On Self-Test (POST) routine is the memory test. As the memory is being tested, press the <Delete> key to enter the main menu of the AMI BIOS Setup Utility. From the main menu, you can access the other setup screens. An AMI BIOS identifi cation string is displayed at the left bottom corner of the screen below the copyright message.
Warning! Do not upgrade the BIOS unless your system has a BIOS-related issue. Flashing the wrong BIOS can cause irreparable damage to the system. In no event shall Supermicro be liable for direct, indirect, special, incidental, or consequential damages arising from a BIOS update. If you have to update the BIOS, do not shut down or reset the system while the BIOS is updating. This is to avoid possible boot failure.
4-2 Main Setup
When you fi rst enter the AMI BIOS Setup Utility , you will enter the Main setup screen. You can always return to the Main setup screen by selecting the Main tab on the top of the screen. The Main BIOS Setup screen is shown below.
System Overview: The following BIOS information will be displayed:
System Time/System Date
Use this option to change the system time and date. Highlight System Time or Sys­tem Date using the arrow keys. Enter new values through the keyboard and press
<Enter>. Press the <Tab> key to move between fi elds. The date must be entered in Day MM/DD/YY format. The time is entered in HH:MM:SS format. (Note: The time is in the 24-hour format. For example, 5:30 P.M. appears as 17:30:00.)
4-2
Page 63
Chapter 4: AMI BIOS
Supermicro X8DT3
BIOS Build Version: This item displays the BIOS revision used in your system. BIOS Build Date: This item displays the date when this BIOS was completed.
AMI BIOS Core Version: This item displays the revision number of the AMI BIOS Core upon which your BIOS was built.
Processor
The AMI BIOS will automatically display the status of the processor used in your system:
CPU Type: This item displays the type of CPU used in the motherboard.
•
Speed: This item displays the speed of the CPU detected by the BIOS.•
Physical Count: This item displays the number of processors installed in your • system as detected by the BIOS.
Logical Count: This item displays the number of CPU Cores installed in your
•
system as detected by the BIOS.
Micro_code Revision: This item displays the revision number of the BIOS Mi-
•
cro_code used in your system.
System Memory
This displays the size of memory available in the system:
Size: This item displays the memory size detected by the BIOS.
•
4-3
Page 64
X8DT3/X8DTi/X8DT3-LN4/X8DTi-LN4 User’s Manual
4-3 Advanced Setup Confi gurations
Use the arrow keys to select Boot Setup and hit <Enter> to access the submenu items:
BOOT Features
Quick Boot
If Enabled, this option will skip certain tests during POST to reduce the time needed for system boot. The options are Enabled and Disabled.
Quiet Boot
This option allows the bootup screen options to be modifi ed between POST mes- sages or the OEM logo. Select Disabled to display the POST messages. Select Enabled to display the OEM logo instead of the normal POST messages. The op­tions are Enabled and Disabled.
AddOn ROM Display Mode
This sets the display mode for the Option ROM. Select Keep Current to use the cur­rent AddOn ROM Display setting. Select Force BIOS to use the Option ROM display mode set by the system BIOS. The options are Force BIOS and Keep Current.
Bootup Num-Lock
This feature selects the Power-on state for Numlock key. The options are Off and On.
Wait For 'F1' If Error
This for ce s the sys tem to wai t until t he ' F1' key is pressed i f an er ror o cc urs . The option s are Dis able d and Enabled.
4-4
Page 65
Chapter 4: AMI BIOS
Hit 'Del' Message Display
This feature displays "Press DEL to run Setup" during POST. The options are
Enabled and Disabled.
Interrupt 19 Capture
Interrupt 19 is the software interrupt that handles the boot disk function. When this item is set to Enabled, the ROM BIOS of the host adaptors will "capture" Interrupt 19 at boot and allow the drives that are attached to these host adaptors to function as bootable disks. If this item is set to Disabled, the ROM BIOS of the host adap­tors will not capture Interrupt 19, and the drives attached to these adaptors will not function as bootable devices. The options are Enabled and Disabled.
Power Confi guration
Power Button Function
If set to Instant_Off, the system will power off immediately as soon as the user hits the power button. If set to 4_Second_Override, the system will power off when the user presses the power button for 4 seconds or longer. The options are Instant_Off and 4_Second_Override.
Restore on AC Power Loss
Use this feature to set the power state after a power outage.
Select Power-Off for the system power to remain off after a power loss.
•
Select Power-On for the system power to be turned on after a power loss. •
Select Last State to allow the system to resume its last state before a power • loss. The options are Power-On, Power-Off and Last State.
Watch Dog Timer
If enable d, the Watch Dog Timer will allow the sys te m t o r e boot when it is inactive for more t han 5 minu tes. The o ption s are Enabl ed and Disabled.
Processor and Clock Options
This submenu allows the user to confi gure the Processor and Clock settings.
C1E Support
Select Enabled to use the feature of Enhanced Halt State. C1E signifi cantly reduces the CPU's power consumption by reducing the CPU's clock cycle and voltage during a "Halt State." The options are Disabled and Enabled.
4-5
Page 66
X8DT3/X8DTi/X8DT3-LN4/X8DTi-LN4 User’s Manual
Hardware Prefetcher (Available when supported by the CPU)
If set to Enabled, the hardware pre fetcher will pre fetch streams of data and instruc­tions from the main memory to the L2 cache in the forward or backward manner to improve CPU performance. The options are Disabled and Enabled.
Adjacent Cache Line Prefetch (Available when supported by the CPU)
The CPU fetches the cache line for 64 bytes if this option is set to Disabled. The CPU fetches both cache lines for 128 bytes as comprised if Enabled.
Intel® Virtualization Technology (Available when supported by the CPU)
Select Enabled to use the feature of Virtualization T echnology to allow one platform to run multiple operating systems and applications in independent partitions, creat­ing mult iple " vi r tu al" sy stems i n one p hysic al c o mput er. The opti ons ar e Enabled and Dis abled. Not e: If there is any change to this setting, you will need to power off an d restar t the system for the change to take effect. Pleas e refer to Intel’s web site for detailed information.
Execute-Disable Bit Capability (Available when supported by the OS and the CPU)
Set to Enabled to enable the Execute Disable Bit which will allow the processor to designate areas in the system memory where an application code can execute and where it cannot, thus preventing a worm or a virus from fl ooding illegal codes to overwhelm the processor or damage the system during an attack. The default is
Enabled. (Refer to Intel and Microsoft Web Sites for more information.)
Simultaneous Multi-Threading (Available when supported by the CPU)
Set to Enabled to use the Simultaneous Multi-Threading Technology, which will result in increased CPU performance. The options are Disabled and Enabled.
Active Processor Cores
Set to Enabled to use a processor's Second Core and beyond. (Please refer to Intel's web site for more information.) The options are All, 1 and 2.
Intel® Speed_Step™ Technology
EIST (Enhanced Intel SpeedStep Technology) allows the system to automatically adjust processor voltage and core frequency in an effort to reduce power consump­tion and heat dissipation. Please refer to Intel’s web site for detailed information. The options are Disable (Disable GV3) and Enable (Enable GV3).
Intel® C-STATE Tech
If enabled, C-State is set by the system automatically to either C2, C3 or C4 state. The options are Disabled and Enabled.
4-6
Page 67
Chapter 4: AMI BIOS
Clock Spread Spectrum
Select Enable to use the feature of Clock Spectrum, which will allow the BIOS to monitor and attempt to reduce the level of Electromagnetic Interference caused by the components whenever needed. The options are Disabled and Enabled.
Advanced Chipset Control
The items included in the Advanced Settings submenu are listed below:
CPU Bridge Confi guration
QPI Links Speed
This feature selects QPI's data transfer speed. The options are Slow-mode, and
Full Speed. QPI Frequency
This selects the desired QPI frequency. The options are Auto, 4.800 GT,
5.866GT, 6.400 GT.
QPI L0s and L1
This enables the QPI power state to low power. L0s and L1 are automatically selected by the motherboard. The options are Disabled and Enabled.
Memory Frequency
This feature forces a DDR3 frequency slower than what the system has detected. The available options are Auto, Force DDR-800, Force DDR-1066, Force DDR­1333 and Force SPD.
Memory Mode
The options are Independent, Channel Mirror, Lockstep and Sparing. Independent - All DIMMs are available to the operating system. Channel Mirror - The motherboard maintains two identical copies of all data in
memory for redundancy. Lockstep - The motherboard uses two areas of memory to run the same set of
operations in parallel. Sparing - A preset threshold of correctable errors is used to trigger fail-over.
The spare memory is put online and used as active memory in place of the failed memory.
4-7
Page 68
X8DT3/X8DTi/X8DT3-LN4/X8DTi-LN4 User’s Manual
Demand Scrubbing
A memory error-correction scheme where the Processor writes corrected data back into the memory block from where it was read by the Processor. The op­tions are Enabled and Disabled.
Patrol Scrubbing
A memory error-correction scheme that works in the background looking for and correcting resident errors. The options are Enabled and Disabled.
Throttling - Closed Loop/Throttling - Open Loop
Throttling improves reliability and reduces power in the processor by automatic voltage control during processor idle states. Available options are Disabled and Enabled. If Enabled, the following items will appear:
Hysteresis Temperature (Closed Loop Only)
Temperature Hysteresis is the temperature lag (in degrees Celsius) after the set DIMM temperature threshold is reached before Closed Loop Throttling begins. The options are Disabled, 1.5oC, 3.0
o
C, and 6.0oC.
Guardband Temperature (Closed Loop Only)
This is the temperature which applies to the DIMM temperature threshold. Each step is in 0.5
o
C increment. The default is [006]. Press "+" or "-" on
your keyboard to change this value.
Inlet Temperature
This is the temperature detected at the chassis inlet. Each step is in 0.5
o
C increment. The default is [070]. Press "+" or "-" on your keyboard to change this value.
Temperature Rise
This is the temperature rise to the DIMM thermal zone. Each step is in
o
0.5
C increment. The default is [020]. Press "+" or "-" on your keyboard to
change this value.
Air Flow
This is the air fl ow speed to the DIMM modules. Each step is one mm/ sec. The default is [1500]. Press "+" or "-" on your keyboard to change this value.
Altitude
This feature defi nes how many meters above or below sea level the system is located. The options are Sea Level or Below, 1~300, 301~600, 601~900, 901~1200, 1201~1500, 1501~1800, 1801~2100, 2101~2400, 2401~2700, 2701~3000.
4-8
Page 69
Chapter 4: AMI BIOS
DIMM Pitch
This is the physical space between each DIMM module. Each step is in 1/1000 of an inch. The default is [400]. Press "+" or "-" on your keyboard to change this value.
North Bridge Confi guration
This feature allows the user to confi gure the settings for the Intel North Bridge chip.
Crystal Beach/DMA (Direct Memory Access)
This feature works in conjunction with the Intel I/O AT (Acceleration Technology) to accelerate the performance of TOE devices. (Note: A TOE device is a special­ized, dedicated processor that is installed on an add-on card or a network card to handle some or all packet processing of this add-on card.) When this feature is set to Enabled, it will enhance overall system performance by providing direct memory access for data transferring. The options are Enabled and Disabled.
Crystal Beach/DCA (Direct Cache Access)
This feature works in conjunction with the Intel I/O AT (Acceleration Technology) to accelerate the performance of the TOE device. When this feature set to Enabled, it will enhance overall system performance by providing direct cache access for data transferring. The options are Enabled and Disabled.
NUMA Support
Select Enabled to use the feature of Non-Uniform Memory Access to improve CPU performance. The options are Enabled and Disabled.
Intel VT-d
Select Enabled to enable Intel's Virtualization Technology support for Direct I/O VT-d by reporting the I/O device assignments to VMM through the DMAR ACPI Tables. This feature offers fully-protected I/O resource-sharing across the Intel platforms, providing the user with greater reliability, security and availability in networking and data-sharing. The settings are Enabled and Disabled.
SouthBridge Confi guration
This feature allows the user to confi gure the settings for the Intel ICH South Bridge chipset.
USB Functions
Select the number of onboard USB ports to be enabled. The Options are: Disabled, 2 USB ports, 4 USB ports, 6 USB ports, 8 Ports, 10 Ports and 12 USB ports.
4-9
Page 70
X8DT3/X8DTi/X8DT3-LN4/X8DTi-LN4 User’s Manual
Legacy USB Support
Select Enabled to use Legacy USB devices. If this item is set to Auto, Legacy USB support will be automatically enabled if a legacy USB device is installed on the motherboard, and vise versa. The settings are Disabled, and Enabled.
USB 2.0 Controller
Select Enabled to activate the onboard USB 2.0 controller. The options are Enabled and Disabled. (The manufacturer's default setting is Enabled. This setting cannot be changed by the user.)
USB 2.0 Controller Mode
This setting allows you to select the USB 2.0 Controller mode. The options are
Hi-Speed (480 Mbps) and Full Speed (12 Mbps).
BIOS EHCI Hand-Off
Select Enabled to enable BIOS Enhanced Host Controller Interface support to provide a workaround solution for an operating system that does not have EHCI Hand-Off support. When enabled, the EHCI Interface will be changed from the BIOS­controlled to the OS-controlled. The options are Disabled and Enabled.
HDA Controller
Select Enabled to activate the onboard High-Defi nition Audio controller. The options are Enabled and Disabled.
Reserved Page Rout
Select PCI to use PCI communication mode for the USB connections. Select LPC to use LPC mode for the USB connections. The options are PCI and LPC.
IDE/SATA Confi guration
When this submenu is selected, the AMI BIOS automatically detects the presence of the IDE devices and displays the following items:
SATA#1 Confi guration
If Compatible is selected, it sets SATA#1 to legacy compatibility mode, while se­lecting Enhanced sets SATA#1 to native SATA mode. The options are Disabled, Compatible and Enhanced.
Confi gure SATA#1 as
This feature allows the user to select the drive type for SATA#1. Select RAID (Intel) to enable Intel's SATA RAID fi rmware to confi gure Intel's SATA RAID settings. Select RAID (Adaptec) to enable Adaptec's SATA RAID fi rmware to confi gure Adaptec's SATA RAID settings. Select AHCI to enable SATA Advanced
4-10
Page 71
Chapter 4: AMI BIOS
Host Interface. (Take caution when using this function. This feature is for ad­vanced programmers only.) The options are IDE, RAID (Intel), RAID (Adaptec) and AHCI.
SATA#2 Confi guration
Selecting Enhanced will set SA T A#2 to native SA TA mode. The options are Disabled, and Enhanced.
Selecting Enhanced will set SA T A#2 to native SA TA mode. The options are Disabled, and Enhanced.
Primary IDE Master/Slave, Secondary IDE Master/Slave, Third IDE Master, and Fourth IDE Master
These settings allow the user to set the parameters of Primary IDE Master/Slave, Secondary IDE Master/Slave, Third and Fourth IDE Master slots. Hit <Enter> to activate the following submenu screen for detailed options of these items. Set the correct confi gurations accordingly. The items included in the submenu are:
Type
Select the type of device connected to the system. The options are Not Installed,
Auto, CD/DVD and ARMD.
LBA/Large Mode
LBA (Logical Block Addressing) is a method of addressing data on a disk drive. In the LBA mode, the maximum drive capacity is 137 GB. For drive capacities over 137 GB, your system must be equipped with a 48-bit LBA mode addressing. If not, contact your manufacturer or install an ATA/133 IDE controller card that supports 48-bit LBA mode. The options are Disabled and Auto.
Block (Multi-Sector Transfer)
Block Mode boosts the IDE drive performance by increasing the amount of data transferred. Only 512 bytes of data can be transferred per interrupt if Block Mode is not used. Block Mode allows transfers of up to 64 KB per interrupt. Select Disabled to allow data to be transferred from and to the device one sector at a time. Select Auto to allow data transfer from and to the device occur multiple sectors at a time if the device supports it. The options are Auto and Disabled.
PIO Mode
The IDE PIO (Programmable I/O) Mode programs timing cycles between the IDE drive and the programmable IDE controller. As the PIO mode increases, the cycle time decreases. The options are Auto, 0, 1, 2, 3, and 4.
Select Auto to allow the AMI BIOS to automatically detect the PIO mode. Use this value if the IDE disk drive support cannot be determined.
4-11
Page 72
X8DT3/X8DTi/X8DT3-LN4/X8DTi-LN4 User’s Manual
Select 0 to allow the AMI BIOS to use PIO mode 0. It has a data transfer rate of 3.3 MBs.
Select 1 to allow the AMI BIOS to use PIO mode 1. It has a data transfer rate of 5.2 MBs.
Select 2 to allow the AMI BIOS to use PIO mode 2. It has a data transfer rate of 8.3 MBs.
Select 3 to allow the AMI BIOS to use PIO mode 3. It has a data transfer rate of 11.1 MBs.
Select 4 to allow the AMI BIOS to use PIO mode 4. It has a data transfer band­width of 32-Bits. Select Enabled to enable 32-Bit data transfer.
DMA Mode
Select Auto to allow the BIOS to automatically detect IDE DMA mode when the IDE disk drive support cannot be determined.
Select SWDMA0 to allow the BIOS to use Single Word DMA mode 0. It has a data transfer rate of 2.1 MBs.
Select SWDMA1 to allow the BIOS to use Single Word DMA mode 1. It has a data transfer rate of 4.2 MBs.
Select SWDMA2 to allow the BIOS to use Single Word DMA mode 2. It has a data transfer rate of 8.3 MBs.
Select MWDMA0 to allow the BIOS to use Multi Word DMA mode 0. It has a data transfer rate of 4.2 MBs.
Select MWDMA1 to allow the BIOS to use Multi Word DMA mode 1. It has a data transfer rate of 13.3 MBs.
Select MWDMA2 to allow the BIOS to use Multi-Word DMA mode 2. It has a data transfer rate of 16.6 MBs.
Select UDMA0 to allow the BIOS to use Ultra DMA mode 0. It has a data transfer rate of 16.6 MBs. It has the same transfer rate as PIO mode 4 and Multi Word DMA mode 2.
Select UDMA1 to allow the BIOS to use Ultra DMA mode 1. It has a data transfer rate of 25 MBs.
Select UDMA2 to allow the BIOS to use Ultra DMA mode 2. It has a data transfer rate of 33.3 MBs.
Select UDMA3 to allow the BIOS to use Ultra DMA mode 3. It has a data transfer rate of 66.6 MBs.
Select UDMA4 to allow the BIOS to use Ultra DMA mode 4. It has a data transfer rate of 100 MBs.
4-12
Page 73
Chapter 4: AMI BIOS
Select UDMA5 to allow the BIOS to use Ultra DMA mode 5. It has a data transfer rate of 133 MBs.
Select UDMA6 to allow the BIOS to use Ultra DMA mode 6. It has a data transfer rate of 133 MBs. The options are Auto, SWDMAn, MWDMAn, and UDMAn.
S.M.A.R.T. For Hard disk drives
Self-Monitoring Analysis and Reporting Technology (SMART) can help predict impending drive failures. Select Auto to allow the AMI BIOS to automatically de­tect hard disk drive support. Select Disabled to prevent the AMI BIOS from using the S.M.A.R.T. Select Enabled to allow the AMI BIOS to use the S.M.A.R.T. to support hard drive disk. The options are Disabled, Enabled, and Auto.
32Bit Data Transfer
Select Enable to enable the function of 32-bit IDE data transfer. The options are
Enabled and Disabled.
Hot Plug
Select Enable to enable the hot plug function for the SATA devices. The options are Enabled and Disabled.
IDE Detect Timeout (sec)
Use this feature to set the time-out value for the BIOS to detect the ATA, ATAPI devices installed in the system. The options are 0 (sec), 5, 10, 15, 20, 25, 30, and
35.
PCI/PnP Confi guration
Clear NVRAM This feature clears the NVRAM during system boot. The options are No and Yes.
Plug & Play OS
Selecting Yes allows the OS to confi gure Plug & Play devices. (This is not required for system boot if your system has an OS that supports Plug & Play.) Select No to allow the AMI BIOS to confi gure all devices in the system.
PCI Latency Timer
This feature sets the latency Timer of each PCI device installed on a PCI bus. Select 64 to set the PCI latency to 64 PCI clock cycles. The options are 32, 64, 96, 128, 160, 192, 224 and 248.
4-13
Page 74
X8DT3/X8DTi/X8DT3-LN4/X8DTi-LN4 User’s Manual
PCI IDE Bus Master
When enabled, the BIOS uses PCI bus mastering for reading/writing to IDE drives. The options are Disabled and Enabled.
Slot 1 Option ROM~Slot 6 Option ROM
Select Enabled to enable Slot 1 Option ROM~Slot 6 Option ROM, which will allow you to boot the computer from a PCI device installed on a PCI slot. The options are Disabled and Enabled.
LAN1 PXE/LAN2 PXE/LAN3 PXE/LAN4 PXE (-LN3 PXE/-LN4 PXE: for LN4 models only)
Select Enabled to enable the onboard LAN1/LAN2 PXE Option ROMs. This is to boot computers using a network interface. The options are Enabled and Dis- abled.
Super IO Device Confi guration
Onboard Floppy Controller
Select Enable to enable the onboard Floppy Controller. The options are Enabled and Disabled.
Floppy A/Floppy B
This feature allows the user to select the type of fl oppy drive connected to the sys- tem as specifi ed. The options are Disabled, 360KB 5 1/4", 1.2MB 5 1/4", 720KB 3 1/2", 1.44MB 3 1/2" and 2.88MB 3 1/2". The default setting for Floppy A is 1.44MB
3 1/2", and for Floppy B is Disabled.
Serial Port1 Address/ Serial Port2 Address
This option specifi es the base I/O port address and the Interrupt Request address of Serial Port 1 and Serial Port 2. Select Disabled to prevent the serial port from accessing any system resources. When this option is set to Disabled, the serial port physically becomes unavailable. Select 3F8/IRQ4 to allow the serial port to use 3F8 as its I/O port address and IRQ 4 for the interrupt address. The options for Serial Port1 are Disabled, 3F8/IRQ4, 3E8/IRQ4, 2E8/IRQ3. The options for Serial Port2 are Disabled, 2F8/IRQ3, 3E8/IRQ4, and 2E8/IRQ3.
Serial Port 2 Mode
Use this feature to confi gure Serial Port 2 mode. The options are Normal, IrDA and ASK IR. IrDA (Infrared Data) is an industry standard for remote control de­vices. ASK IR (Amplitude Shifted Keying Infrared) is a protocol compatible with Sharp® branded PDAs and other infrared devices.
4-14
Page 75
Chapter 4: AMI BIOS
Watch Dog Timer
If enabled, the Watch Dog Timer will allow the system to reboot when it is inactive for more than 5 minutes. The options are Enabled and Disabled.
Remote Access Confi guration
Remote Access This allows the user to enable the Remote Access feature. The options are Dis-
abled and Enabled.
If Remote Access is set to Enabled, the following items will display:
Serial Port Number
This feature allows the user decide which serial port to be used for Console Redirection. The options are COM 1, COM2, and Onboard IPMI.
Base Address, IRQ
This item displays the base address and IRQ of the serial port used for Console Redirection.
Serial Port Mode
This feature allows the user to set the serial port mode for Console Redirection. The options are 115200 8, n 1; 57600 8, n, 1; 38400 8, n, 1; 19200 8, n, 1; and 9600 8, n, 1.
Flow Control
This feature allows the user to set the fl ow control for Console Redirection. The options are None, Hardware, and Software.
Redirection After BIOS POST
Select Disabled to turn off Console Redirection after Power-On Self-Test (POST). Select Always to keep Console Redirection active all the time after POST. (Note: This settin g may not be sup por ted by so me oper ating sys tems.) Select Boot Loader to keep Console Redirection active during POST and Boot Loader. The opti ons are D isabl ed, Boot L oader, and Always.
Terminal Type
This feature allows the user to select the target terminal type for Console Redi­rection. The options are ANSI, VT100, and VT-UTF8.
VT-UTF8 Combo Key Support
A terminal keyboard defi nition that provides a way to send commands from a remote console. Available options are Enabled and Disabled.
4-15
Page 76
X8DT3/X8DTi/X8DT3-LN4/X8DTi-LN4 User’s Manual
Sredir Memory Display Delay
This feature defi nes the length of time in seconds to display memory information. The options are No Delay, Delay 1 Sec, Delay 2 Sec, and Delay 4 Sec.
System Health Monitor
This feature allows the user to monitor system health and review the status of each item as displayed.
CPU Overheat Alarm
This option allows the user to select the CPU Overheat Alarm setting which de­termines when the CPU OH alarm will be activated to provide warning of possible CPU overheat.
Warning!
1. Any temperature that exceeds the CPU threshold temperature pre-
defi ned by the CPU manufacturer may result in CPU overheat or system instability. When the CPU temperature reaches this predefi ned threshold, the CPU and system cooling fans will run at full speed.
2. To avoid possible system overheating, please be sure to provide ad­equate airfl ow to your system.
The options are:
The Early Alarm: Select this setting if you want the CPU overheat alarm (includ-
•
ing the LED and the buzzer) to be triggered as soon as the CPU temperature reaches the CPU overheat threshold as predefi ned by the CPU manufacturer.
The Default Alarm
• : Select this setting if you want the CPU overheat alarm
(including the LED and the buzzer) to be triggered when the CPU temperature reaches about 5 manufacturer to give the CPU and system fans additional time needed for CPU and system cooling. In both the alarms above, please take immediate action as shown below.
CPU Temperature/System Temperature
This feature displays current temperature readings for the CPU and the System. The following items will be displayed for your reference only:
o
C above the threshold temperature as predefi ned by the CPU
CPU Temperature
The CPU thermal technology that reports absolute temperatures (Celsius/Fahr­enheit) has been upgraded to a more advanced feature by Intel in its newer processors. The basic concept is each CPU is embedded by unique temperature
4-16
Page 77
Chapter 4: AMI BIOS
information that the motherboard can read. This ‘Temperature Threshold’ or ‘Tem­perature Tolerance’ has been assigned at the factory and is the baseline on which the motherboard takes action during different CPU temperature conditions (i.e., by increasing CPU Fan speed, triggering the Overheat Alarm, etc). Since CPUs can have different ‘Temperature Tolerances’, the installed CPU can now send informa­tion to the motherboard what its ‘Temperature Tolerance’ is, and not the other way around. This results in better CPU thermal management.
Supermicro has leveraged this feature by assigning a temperature status to certain thermal conditions in the processor (Low, Medium and High). This makes it easier for the user to understand the CPU’s temperature status, rather than by just simply seeing a temperature reading (i.e., 25
o
C). The CPU Temperature feature will display
the CPU temperature status as detected by the BIOS: Low – This level is considered as the ‘normal’ operating state. The CPU temperature
is well below the CPU ‘Temperature T olerance’. The motherboard fans and CPU will run normally as confi gured in the BIOS (Fan Speed Control).
User intervention: No action required. Medium – The processor is running warmer. This is a ‘precautionary’ level and
generally means that there may be factors contributing to this condition, but the CPU is still within its normal operating state and below the CPU ‘Temperature Tolerance’. The motherboard fans and CPU will run normally as confi gured in the BIOS. The fans may adjust to a faster speed depending on the Fan Speed Control settings.
User intervention: No action is required. However, consider checking the CPU fans and the chassis ventilation for blockage.
High – The processor is running hot. This is a ‘caution’ level since the CPU’s ‘Tem­perature Tolerance’ has been reached (or has been exceeded) and may activate an overheat alarm.
User intervention: If the system buzzer and Overheat LED has activated, take action immediately by checking the system fans, chassis ventilation and room temperature to correct any problems.
Notes: 1. The system may shut down if it continues for a long period to prevent damage to the CPU.
2. The information provided above is for your reference only. For more information on thermal management, please refer to Intel’s Web site at www.Intel.com.
System Temp erature: The system temper ature wil l be displ ayed (in deg rees in Celsiu s and Fahrenh eit) as it is detec ted by the BI OS.
4-17
Page 78
X8DT3/X8DTi/X8DT3-LN4/X8DTi-LN4 User’s Manual
Voltage Monitoring
CPU1 Vcore/CPU2 Vcore, CPU1 DIMM/CPU2 DIMM, 1.5V, 3.3Vcc (V), 3.3V SB (V), 12Vcc (V), 5Vin, and Battery Voltage.
System Fan Monitor
This feature allows the user to decide how the system controls the speeds of the onboard fans. The CPU temperature and the fan speed are correlative. When the CPU on-die temperature increases, the fan speed will also increase, and vice versa. Select Workstation if your system is used as a Workstation. Select Server if your system is used as a Server. Select “Disabled, (Full Speed @12V)” to disable the fan speed control function and allow the onboard fans to constantly run at the full speed (12V). The Options are: Disabled (@full-speed), 4-pin (Server), 4-pin (Workstation), 4-pin (Quiet) and , 4-pin (Super Quiet).
Fan1 ~ Fan 8 Reading
This feature displays the fan speed readings from fan interfaces Fan1 through Fan8. (Fan7 is CPU1 Fan and Fan8 is CPU2 Fan.)
ACPI Confi guration
Use this feature to confi gure Advanced Confi guration and Power Interface (ACPI) power management settings for your system.
ACPI Version Features
The options are ACPI v1.0, ACPI v2.0 and ACPI v3.0. Please refer to ACPI's website for further explanation: http://www.acpi.info/.
ACPI APIC Support
Select Enabled to include the ACPI APIC Table Pointer in the RSDT (Root System Description Table) pointer list. The options are Enabled and Disabled.
APIC ACPI SCI IRQ
When this item is set to Enabled, APIC ACPI SCI IRQ is supported by the system. The options are Enabled and Disabled.
Headless Mode
This feature is used to enable system to function without a keyboard, monitor or mouse attached The options are Enabled and Disabled.
High Performance Event Timer
Select Enabled to activate the High Performance Event Timer (HPET) that produces periodic interrupts at a much higher frequency than a Real-time Clock (RTC) does in synchronizing multimedia streams, providing smooth playback and reducing the de-
4-18
Page 79
Chapter 4: AMI BIOS
pendency on other timestamp calculation devices, such as an x86 RDTSC Instruc­tion embedded in the CPU. The High Performance Event Timer is used to replace the 8254 Programmable Interval Timer. The options are Enabled and Disabled.
Trusted Computing
TCG/TPM (Trusted Platform Module) Support
Select Yes on this item and enable the TPM jumper on the motherboard to enable TCG (TPM 1.1/1.2)/TPM support in order to improve data integrity and network security. The options are No and Yes.
If this feature is set to Yes, the following items will display:
TPM Enable/Disable Status
This item displays the status of TPM Enabled/Disabled state.
TPM Owner Status
This item displays the status of TPM Ownership.
IPMI Confi guration
Intelligent Platform Management Interface (IPMI) is a set of common interfaces that IT administrators can use to monitor system health and to manage the system as a whole. For more information on the IPMI specifi cations, please visit Intel's website at www.intel.com.
Status of BMC
Baseboard Management Controller (BMC) manages the interface between system management software and platform hardware. This is an informational feature which returns the status code of the BMC micro controller.
View BMC System Event Log
This feat ur e d i sp l ays t h e BMC System Event Log (SE L). It shows the total number of entries of BMC System Events.
To view an event, select an Entry Number and pressing <Enter> to display the information as shown in the screen.
SEL Entry Number
•
SEL Record ID•
SEL Record Type•
4-19
Page 80
X8DT3/X8DTi/X8DT3-LN4/X8DTi-LN4 User’s Manual
Timestamp•
Generator ID•
Event Message Format User•
Event Sensor Type•
Event Sensor Number,•
Event Dir Type•
Event Data.•
Clear BMC System Event Log
Clear BMC System Log
Select OK and press the <Enter> key to clear the BMC system log. Select Cancel to keep the BMC System log. The options are OK and Cancel.
Caution: Any cleared information is unrecoverable. Make absolutely sure that you no longer need any data stored in the log before clearing the BMC Event Log.
Set LAN Confi guration
Set this feature to confi gure the IPMI LAN adapter with a network address as shown in the following graphics.
Channel Number Enter the channel number for the SET LAN Confi g command. This is initially set
to [1]. Press "+" or "-" on your keyboard to change the Channel Number. Channel Number Status This feature returns the channel status for the Channel Number selected above:
"Channel Number is OK" or "Wrong Channel Number".
IP Address Source
This features allows the user to select how an IP address is assigned to a cli­ent computer or network device. Select DHCP (Dynamic Host Confi guration Protocol) to allow a client (computer or device) obtains an IP address from a DHCP server that manages a pool of IP addresses and network information on a "request and grant" basis. Upon time-out (or lease expiration), the IP address assigned to the client can be reassigned to a new client. Select Static (Static
4-20
Page 81
Chapter 4: AMI BIOS
Allocation) to allow the host server to allocate an IP address based on a table containing MAC Address/IP Address pairs that are manually entered (probably by a network administrator). Only clients with a MAC address listed in the MAC/ IP Address Table will be assigned an IP address. The IP Address allocated to the client is on a longer term basis than that assigned by the DHCP mentioned in the other option. The options are DHCP and Static.
IP Address Confi guration
This submenu displays the following IP Address Confi guration information.
Parameter Selector
This item displays the parameter of your IP Address confi guration.
IP Address
This item displays the IP address of this computer. IP addresses are 6 two-digit hexadecimal numbers (Base 16, 0 ~ 9, A, B, C, D, E, F) separated by dots. (i.e.,
00.30.48.D0.D4.60).
Current IP Address in BMC
This item displays the current IP address used for your IPMI connection.
MAC Address Confi guration
This submenu displays the following MAC Address Confi guration information.
Parameter Selector
Use this feature to select the parameter of your Mac Address confi guration.
MAC Address
This item displays the MAC address of this computer. MAC addresses are 6 two-digit hexadecimal numbers (Base 16, 0 ~ 9, A, B, C, D, E, F) separated by dots. (i.e., 00.30.48.D0.D4.60).
Current MAC Address in BMC
This item displays the current MAC address used for your IPMI connection.
Subnet Mask Confi guration
Subnet masks tell the network which subnet this machine belongs to. The value of each three-digit number separated by dots should not exceed 255.
Parameter Selector
Use this feature to select the parameter of your Subnet Masks confi guration.
4-21
Page 82
X8DT3/X8DTi/X8DT3-LN4/X8DTi-LN4 User’s Manual
Subnet Mask
This item displays the current subnet mask setting for your IPMI connection.
VLAN Tagging
Select Enabled to enable VLAN (Virtual LAN) Tagging support which allows mul­tiple networks to transparently share the same physical network without leaking information between the bridged networks. VLAN Tagging complies with the IEEE
802.1Q Standards. The options are Enabled and Disabled.
SEL PEF Confi guration
PEF Confi guration
Set this feature to confi gure the Platform Event Filter (PEF). PEF interprets BMC events and performs actions based on pre-determined settings or 'traps' under IPMI 1.5 specifi cations. Powering the system down or sending an alert when a triggering event is detected. The default is Disabled.
The following will appear if PEF Support is set to Enabled.
PEF Action Global Control
These are the different actions based on BMC events. The options are Alert, Power Down, Reset System, Power Cycle, OEM Action, Diagnostic Interface.
Alert Startup Delay
This feature inserts a delay during startup for PEF alerts. The options are En­abled and Disabled.
PEF Alert Startup Delay
This sets the pre-determined time to delay PEF alerts after system power-ups and resets. Refer to Table 24.6 of the IPMI 1.5 Specifi cation for more information at www.intel.com. The options are No Delay, 30 sec, 60 sec, 1.5 min, 2.0 min.
Startup Delay This feature enables or disables startup delay. The options are Enabled and
Disabled.
PEF Startup Delay
This sets the pre-determined time to delay PEF after system power-ups and resets. Refer to Table 24.6 of the IPMI 1.5 Specifi cation for more information at www.intel.com. The options are No Delay, 30 sec, 60 sec, 1.5 min, 2.0 min.
4-22
Page 83
Chapter 4: AMI BIOS
Event Message for PEF Action
This enables of disables Event Messages for PEF action. Refer to Table 24.6 of the IPMI 1.5 Specifi cation for more information at www.intel.com. The options are Disabled and Enabled.
BMC Watch Dog Timer Action
Allows the BMC to reset or power down the system if the operating system hangs or crashes. The options are Disabled, Reset System, Power Down, Power Cycle.
BMC Watch Dog TimeOut [Min:Sec]
This option appears if BMC Watch Dog Timer Action (above) is enabled. This is a timed delay in minutes or seconds, before a system power down or reset after an operating system failure is detected. The options are [5 Min], [1 Min], [30 Sec], and [10 Sec].
DMI Event Log
View Event Log
Use this option to view the System Event Log.
Mark all events as read
This option marks all events as read. The options are OK and Cancel.
Clear event log
This option clears the Event Log memory of all messages. The options are OK and Cancel.
4-4 Security Settings
The AMI BIOS provides a Supervisor and a User password. If you use both pass­words, the Supervisor password must be set fi rst.
4-23
Page 84
X8DT3/X8DTi/X8DT3-LN4/X8DTi-LN4 User’s Manual
Supervisor Password
This item indicates if a Supervisor password has been entered for the system. "Not Installed" means a Supervisor password has not been used.
User Password
This item indicates if a user password has been entered for the system. "Not I n­stalle d" means that a u ser password has not been used.
Change Supervisor Password
Select this feature and press <Enter> to access the submenu, and then enter a new Supervisor Password.
User Access Level (Available when Supervisor Password is set as above) Use this feature to set the user's access level. The options are:
Full Access
• : grants full User read and write access to the Setup Utility,
View Only: allows access to the Setup Utility, but cannot change the fi elds,
•
Limited: allows only limited fi elds to be changed such as Date and Time, •
No Access: prevents User access to the Setup Utility.•
Change User Password
Select this feature and press <Enter> to access the submenu, and then enter a new User Password.
Clear User Password (Available only if User Password has been set) This item allows you to clear a user password after it has been entered.
Password Check
This item allows you to check a password after it has been entered. The options are Setup and Always.
Boot Sector Virus Protection
When Enabled, the AMI BIOS displays a warning when any program (or virus) is­sues a Disk Format command or attempts to write to the boot sector of the hard disk drive. The options are Enabled and Disabled.
4-5 Boot Confi guration
Use this feature to confi gure boot settings.
4-24
Page 85
Boot Device Priority
Chapter 4: AMI BIOS
This feature allows the user to specify the sequence of priority for the Boot Device. The settings are 1st boot device, 2nd boot device, 3rd boot device, 4th boot device, 5th boot device and Disabled.
1st Boot Device - 1st Floppy Drive
•
2nd Boot Device - [USB: XXXXXXXXX]•
Hard Disk Drives
This feature allows the user to specify the boot sequence from all available hard disk drives. The settings are Disabled and a list of all hard disk drives that have been detected (i.e., 1st Drive, 2nd Drive, 3rd Drive, etc).
Removable Drives
This feature allows the user to specify the boot sequence from available Removable Drives. The settings are 1st boot device, 2nd boot device, and Disabled.
1st Drive - 1st Floppy Drive
•
2nd Drive - [USB: XXXXXXXXX]•
CD/DVD Drives
This feature allows the user to specify the boot sequence from available CD/DVD Drives (i.e., 1st Drive, 2nd Drive, etc).
4-25
Page 86
X8DT3/X8DTi/X8DT3-LN4/X8DTi-LN4 User’s Manual
4-6 Exit Options
Select the Exit tab from the AMI BIOS Setup Utility screen to enter the Exit BIOS Setup screen.
Save Changes and Exit
When you have completed the system confi guration changes, select this option to leave the BIOS Setup Utility and reboot the computer, so the new system con­fi guration parameters can take effect. Select Save Changes and Exit from the Exit menu and press <Enter>.
Discard Changes and Exit
Select this option to quit the BIOS Setup without making any permanent changes to the system confi guration, and reboot the computer. Select Discard Changes and Exit from the Exit menu and press <Enter>.
Discard Changes
Select this option and press <Enter> to discard all the changes and return to the AMI BIOS Utility Program.
Load Optimal Defaults
To set this feature, select Load Optimal Defaults from the Exit menu and press <Enter>. Then, select OK to allow the AMI BIOS to automatically load Optimal De­faults to the BIOS Settings. The Optimal settings are designed for maximum system performance, but may not work best for all computer applications.
Load Fail-Safe Defaults
To set this feature, select Load Fail-Safe Defaults from the Exit menu and press <Enter>. The Fail-Safe settings are designed for maximum system stability, but not for maximum performance.
4-26
Page 87
Chapter 4: AMI BIOS
4-7 BIOS Recovery
Warning! Do not upgrade the BIOS unless your system has a BIOS-related
issue. Flashing the wrong BIOS can cause irreparable damage to the system. In no event shall Supermicro be liable for direct, indirect, special, incidental, or consequential damages arising from a BIOS update. If you need to update the BIOS, do not shut down or reset the system while the BIOS is updating. This is to avoid possible boot failure.
How to Recover the AMIBIOS Image (-the Main BIOS Block)
An AMIBIOS fl ash chip consists of a boot sector block, and a main BIOS code block (a main BIOS image). The boot sector block contains critical BIOS code, including memory detection and recovery code to be used to fl ash a new BIOS image if the original BIOS Image is corrupted. When the system is powered on, the boot sector code executes fi rst. Once it is completed, the main BIOS code will continue with system initialization and complete the bootup process.
Notes: BIOS Recovery described below is used when the main BIOS block crashes. However, when the BIOS Boot sector crashes, you will need to send the motherboard back to Supermicro for RMA repairs.
4.7.1 Boot Sector Recovery from a USB Device
This feature allows the user to recover a BIOS image using a USB device without additional utilities needed. A user can download the BIOS image into a USB fl ash device, and name the fi le "SUPER.ROM" for the recovery process to load the fi le. A USB fl ash device such as a USB Flash Drive, a USB CDROM or a USB CDRW device can be used for this purpose,
Insert the USB device that contains the new BIOS image (the ROM fi les) 1. saved in a root directory into your USB drive.
While turning the power on, press and hold <Ctrl> and <Home> at the same 2. time until the USB Access LED Indicator comes on. This might take a few seconds.
Once the USB drive LED is on, release the <Ctrl> and <Home> keys. 3. AMIBIOS will issue beep codes to indicate that the BIOS ROM fi le is being updated.
When BIOS fl ashing is completed, the computer will reboot. Do not interrupt 4. the fl ashing process until it is completed.
4-27
Page 88
X8DT3/X8DTi/X8DT3-LN4/X8DTi-LN4 User’s Manual
4.7.2 Boot Sector Recovery from an IDE CD-ROM
This process is almost identical to the process of Boot Sector Recovery from a USB device, except that the BIOS image fi le is loaded from a CD-ROM. Use a CD-R or CD-RW drive to burn a CD with the BIOS image fi le in it, and name the fi le "SUPER. ROM" for the recovery process to load the fi le.
4.7.3 Boot Sector Recovery from a Serial Port ("Serial Flash")
This process, also known as "Serial Flash," allows the user to use a serial port to load a BIOS image for Boot Sector recovery . This feature is usually used for embed­ded systems that rely on a serial port for remote access and debugging.
Requirements
In order to use Serial Flash for Boot Sector Recovery, you will need to meet the following requirements.
The "Target system," the system that needs BIOS updates, must have a serial
•
port and "Serial Flash" support embedded in the BIOS image fi le. The "Host system" should also have a serial port and a terminal program that
•
supports XModem Transfer protocol (Hyper Terminal for the Windows operating systems, and minicom for Linux/FreeSBD, etc.).
A Null_modem serial cable
•
How to use Serial Flash for Boot Sector Recovery
Connect a Null_modem serial cable between the target system and the host 1. system that runs the terminal program.
Make sure that the new BIOS Image fi le is accessible for the host system.2.
Start the terminal program on the host system and create a new connection. 3. Use the following communication parameters for the new connection.
Bits per second: 115200 bits/sec.
•
Data Bits: 8• Parity: None• Stop Bit: 1• Flow Control: None•
4-28
Page 89
Chapter 4: AMI BIOS
4. Power on your system and click the <Connect> button in the Hyper Terminal. The terminal screen will display the following messages.
Press <SpaceBar> to update BIOS. Confirm update BIOS? (y/n) y Begin remote BIOS flash? (y/n) y Starting remote flash. Upload new BIOS file using Xmodem protocol.
5. Following the instructions given on the screen to update the BIOS. These instructions are also shown below.
a. At the prompt, press the <SpaceBar> to update the BIOS. b. When asked to confi rm BIOS updating, press <y> to confi rm BIOS
updates.
c. Press <y> again to begin fl ashing BIOS remotely.
Note: Be sure to complete Steps a~c above quickly because you have a second or less to do so.
6. Once you've completed the instructions given, a screen will display to indicate that remote fl ashing is starting and the new BIOS fi le is being uploaded.
7. To use Hyper Terminal to transfer the XModem protocol by using the "Send File" dialog under the "Transfer" menu, follow the instructions below to com­plete XModem transfers.
a. Select the "Transfer" menu and enter <Send>.
b. Specify the location of the ROM fi le and select the proper protocol (XMo-
dem).
c. Press <Send> to start ROM File extraction. (See the picture below.)
4-29
Page 90
X8DT3/X8DTi/X8DT3-LN4/X8DTi-LN4 User’s Manual
d. Once the ROM fi le extraction is completed, the message: "New BIOS re-
ceived OK" will display.
8. Once remote BIOS fl ash is completed, the system will reboot.
Note: AMIBIOS Serial Flash will work with any terminal communications program that supports VT-100 and XModem protocols, including protocols designed for GNU/LINUX & BSD operating systems such as minicom. It is recommended that the terminal program be confi gured to use the 'CR/ LF' style of line termination.
4-30
Page 91
Appendix A: BIOS POST Error Codes
Appendix A
BIOS Error Beep Codes
During the POST (Power-On Self-Test) routines, which are performed each time the system is powered on, errors may occur.
Non-fatal errors are those which, in most cases, allow the system to continue the boot-up process. The error messages normally appear on the screen.
Fatal errors are those which will not allow the system to continue the boot-up procedure. If a fatal error occurs, you should consult with your system manufac­turer for possible repairs.
A-1 BIOS Error Beep Codes
BIOS Error Beep Codes
Beep Code Error Message Description
1 beep Refresh Circuits have been reset.
(Ready to power up)
5 short beeps + 1 long beep
8 beeps Display memory
1 continuous beep (with the front panel OH LED on)
Memory error No memory detected in the
system Video adapter missing or with
read/write error System Overheat 1 continuous beep with the
faulty memory
front panel OH LED on
A-1
Page 92
X8DT3/X8DTi/X8DT3-F/X8DTi-F/X8DT3-LN4F/X8DTi-LN4F User's Manual
Notes
A-2
Page 93
Appendix B: Installing the Windows OS
Appendix B
Installing the Windows OS
After all hardware components have been installed, you must fi rst confi gure Intel South Bridge RAID Settings before you install the Windows OS and other software drivers. T o confi gure RAID settings, please refer to RAID Confi guration User Guides posted on our website at www.supermicro.com/support/manuals.
B-1 Installing the Windows OS to a RAID System
Insert Microsoft's Windows XP/2003/2008/Vista Setup CD in the CD Driver, 1. and the system will start booting up from CD.
Press the <F6> key when the message-" Press F6 if you need to install a 2. third party SCSI or RAID driver" displays.
When the Windows XP/2003/2008/Vista Setup screen appears, press "S" to 3. specify additional device(s).
Insert the driver diskette-"ITE RAID XP/2003/2008/Vista Driver for IDE" into 4. Drive A: and press the <Enter> key.
When the Windows OS Setup screen appears, press "S" to specify additional 5. device(s).
Insert the driver diskette-"Intel AA RAID XP/2003/2008/Vista Driver for 6. ICH10R" into Drive A: and press the <Enter> key.
Choose the Intel(R) ICH10R 7. SATA RAID Controller from the list indicated in the Windows OS Setup Screen, and press the <Enter> key.
Press the <Enter> key to continue the installation process. (If you need to 8. specify any additional devices to be installed, do it at this time.) Once all devices are specifi ed, press the <Enter> key to continue with the installation.
From the Windows OS Setup screen, press the <Enter> key. The Windows 9. OS Setup will automatically load all device fi les and then, continue the Win- dows OS installation.
After the Windows OS Installation is completed, the system will automatically 10. reboot.
B-1
Page 94
X8DT3/X8DTi/X8DT3-F/X8DTi-F/X8DT3-LN4F/X8DTi-LN4F User's Manual
B-2 Installing the Windows OS to a Non-RAID System
Insert Microsoft's Windows XP/Windows 2003/Windows 2008/Windows Vista 1. Setup CD in the CD Driver, and the system will start booting up from CD.
Continue with the OS installation. The Windows OS Setup screen will display.2.
From the Windows OS Setup screen, press the <Enter> key. The Windows 3. OS Setup will automatically load all device fi les and then continue with the Windows OS installation.
After the Windows OS Installation is completed, the system will automatically 4. reboot.
Insert the Supermicro Setup CD that came with your motherboard into the CD 5. Drive during system boot, and the main screen will display.
B-2
Page 95
Appendix C: Software Installation Instructions
Appendix C
Software Installation Instructions
C-1 Installing Software Programs
After you've installed the Windows Operating System, a screen as shown below will appear. You are ready to install software programs and drivers that have not yet been installed. To install these software programs and drivers, click the icons to the right of these items.
Notes:
1. Click the icons showing a hand writing on the paper to view the readme fi les for each item. Click on a computer icon to the right of an item to install an item (from top to the bottom) one at a time. After installing each item, you must re-boot the system before proceeding with the next item on the list. The bottom icon with a CD on it allows you to view the entire contents of the CD.
2. When making a storage driver diskette from booting into a Driver CD, please set the SATA Confi guration to "Compatible Mode" and confi gure SATA as IDE in the BIOS Setup. After making the driver diskette, be sure to change the SATA settings back to your original settings.
Driver/Tool Installation Display Screen
C-1
Page 96
X8DT3/X8DTi/X8DT3-F/X8DTi-F/X8DT3-LN4F/X8DTi-LN4F User's Manual
C-2 Confi guring Supero Doctor III
The Supero Doctor III program is a Web-base management tool that supports remote management capability. It includes Remote and Local Management tools. The local management is called the SD III Client. The Supero Doctor III program included on the CDROM that came with your motherboard allows you to monitor the environment and operations of your system. Supero Doctor III displays crucial system information such as CPU temperature, system voltages and fan status. See the Figure below for a display of the Supero Doctor III interface.
Note: 1 The default user name and password are ADMIN. Note 2: In the Windows OS environment, the Supero Doctor III settings
take precedence over the BIOS settings. When fi rst installed, Supero Doc- tor III adopts the temperature threshold settings previously set in BIOS. Any subsequent changes to these thresholds must be made within Supero Doc­tor, since the SD III settings override the BIOS settings. For the Windows OS to adopt the BIOS temperature threshold settings, please change the SDIII settings to be the same as those set in BIOS.
Supero Doctor III Interface Display Screen-I (Health Information)
C-2
Page 97
Appendix C: Software Installation Instructions
Supero Doctor III Interface Display Screen-II (Remote Control)
Note: SD III Software Revision 1.0 can be downloaded from our Web
site at: f tp://ft p.superm icro.co m/utilit y/Supero _D octor_I II/. You c an also download SDIII User's Guide at: http://www.supermicro.com/PRODUCT/ Manuals/SDIII/UserGuide.pdf. For Linux, we will still recommend that you use Supero Doctor II.
C-3
Page 98
X8DT3/X8DTi/X8DT3-F/X8DTi-F/X8DT3-LN4F/X8DTi-LN4F User's Manual
Notes
C-4
Loading...