The information in this User’s Manual has been carefully reviewed and is believed to be accurate.
The vendor assumes no responsibility for any inaccuracies that may be contained in this document,
makes no commitment to update or to keep current the information in this manual, or to notify any
person or organization of the updates. Please Note: For the most up-to-date version of this
manual, please see our web site at www.supermicro.com.
Super Micro Computer, Inc. ("Supermicro") reserves the right to make changes to the product
described in this manual at any time and without notice. This product, including software, if any,
and documentation may not, in whole or in part, be copied, photocopied, reproduced, translated or
reduced to any medium or machine without prior written consent.
IN NO EVENT WILL SUPERMICRO BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL,
SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO
USE THIS PRODUCT OR DOCUMENTATION, EVEN IF ADVISED OF THE POSSIBILITY OF
SUCH DAMAGES. IN PARTICULAR, SUPERMICRO SHALL NOT HAVE LIABILITY FOR ANY
HARDWARE, SOFTW ARE, OR DA TA STORED OR USED WITH THE PRODUCT, INCLUDING THE
COSTS OF REPAIRING, REPLACING, INTEGRATING, INSTALLING OR RECOVERING SUCH
HARDWARE, SOFTWARE, OR DATA.
Any disputes arising between manufacturer and customer shall be governed by the laws of Santa
Clara County in the State of California, USA. The State of California, County of Santa Clara shall
be the exclusive venue for the resolution of any such disputes. Super Micro's total liability for all
claims will not exceed the price paid for the hardware product.
FCC Statement: This equipment has been tested and found to comply with the limits for a Class
A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the manufacturer’s instruction manual, may cause harmful
interference with radio communications. Operation of this equipment in a residential area is likely
to cause harmful interference, in which case you will be required to correct the interference at your
own expense.
California Best Management Practices Regulations for Perchlorate Materials: This Perchlorate
warning applies only to products containing CR (Manganese Dioxide) Lithium coin cells. “Perchlorate
Material-special handling may apply. See www.dtsc.ca.gov/hazardouswaste/perchlorate”
WARNING: Handling of lead solder materials used in this
product may expose you to lead, a chemical known to
the State of California to cause birth defects and other
reproductive harm.
Manual Revision 1.0a
Release Date: April 30, 2009
Unless you request and receive written permission from Super Micro Computer, Inc., you may not
copy any part of this document.
Information in this document is subject to change without notice. Other products and companies
referred to herein are trademarks or registered trademarks of their respective companies or mark
holders.
This manual is written for system integrators, PC technicians and knowledgeable
PC users. It provides information for the installation and use of the
X8DTi/X8DT3-F/X8DTi-F/X8DT3-LN4F/X8DTi-LN4F motherboard.
About this Motherboard
The X8DT3/X8DTi/X8DT3-F/X8DTi-F/X8DT3-LN4F/X8DTi-LN4F supports
the Intel® 5500 Series Processor platform, the fi rst dual-processing platform that
supports the Intel QuickPath Interconnect (QPI) Technology, providing the next generation point-to-point system interface to replace the current Front Side Bus. With
the 5500 Series Processor platform built in, the X8DT3/X8DTi/X8DT3-F/X8DTi-F/
X8DT3-LN4F/X8DTi-LN4F offers substantial enhancement in system performance
with increased bandwidth and unprecedented scalability optimized for high-end
servers, High Performance Computing (HPC) systems and intensive applications.
Please refer to our web site (http://www.supermicro.com/products/) for updates
on supported processors. This product is intended to be installed and serviced by
professional technicians.
Preface
X8DT3/
Manual Organization
Chapter 1 describes the features, specifi cations and performance of the mother-
board and provides detailed information about the chipset.
Chapter 2 provides hardware installation instructions. Read this chapter when in-
stalling the processor, memory modules and other hardware components into the
system. If you encounter any problems, see Chapter 3, which describes troubleshooting procedures for video, memory and system setup stored in the CMOS.
Chapter 4 includes an introduction to the BIOS and provides detailed information
on running the CMOS Setup utility.
Appendix A lists BIOS POST Error Codes. Appendix B and Appendix C provide
the Windows OS and Other Software Installation Instructions.
Conventions Used in the Manual
Special attention should be given to the following symbols for proper installation and
to prevent damage done to the components or injury to yourself:
Danger/Caution: Instructions to be strictly followed to prevent catastrophic
system failure or to avoid bodily injury.
C-2 Confi guring Supero Doctor III .........................................................................C-2
viii
Page 9
Chapter 1: Introduction
Chapter 1
Introduction
1-1 Overview
Checklist
Congratulations on purchasing your computer motherboard from an acknowledged
leader in the industry. Supermicro boards are designed with the utmost attention
to detail to provide the highest standards in quality and performance. Check that
the following items have all been included with your motherboard. If anything listed
here is damaged or missing, contact your retailer.
The following items are included in the retail box.
One (1) Supermicro Mainboard
•
One (1) fl oppy ribbon cable (CBL-0022L) •
One (1) USB cable (CBL-0083L)•
One (1) Serial/COM cable (CBL-010L)•
Four (4) Serial ATA cables (CBL-0044L) (For X8DT3/X8DT3-F/X8DT3-LN4F)•
Six (6) Serial ATA cables (CBL-0044L) (For X8DTi/X8DTi-F/X8DTi-LN4F)•
Two (2) SAS cable for SATA/SAS Backplane (CBL-0097L-02) (For X8DT3/•
X8DT3-F/X8DT3-LN4F)
One (1) I/O backpanel shield (MCP-260-00027-0N)
•
One (1) Supermicro CD containing drivers and utilities•
Note: The drawings and pictures shown in this manual were based on the
latest PCB Revision available at the time of publishing of the manual. The
motherboard you’ve received may or may not look exactly the same as
the graphics shown in the manual.
LAN Port 3, LAN Port 4, and LAN Controller#2 are for the X8DT3/i-LN4F 1.
only. IPMI Dedicated LAN is for X8DT3/i-F, X8DT3/i-LN4F only.
SAS connectors, jumpers, and the LSI 1068E chip are available on the 2.
X8DT3/-F/-LN4F only. For SAS RAID confi guration, refer to the LSI User
Guide posted on our website @ http://www.supermicro.com/support/manuals/
IPMI 2.0 and the Dedicated LAN (w/KVM support) are available on the 3.
X8DT3/i-F/-LN4F only. For more information, please refer to the user guide
posted on our website @ http://www.supermicro.com/support/manuals/
Jumpers not indicated are for test purposes only. 1.
Fan6
Fan5
Dedicated LAN
(X8DT3/i-F/-LN4F only)
JLAN1
JLAN2
JI2C1
JI2C2
JPW2
P2-DIMM3A
P2-DIMM3B
P2-DIMM2A
P2-DIMM2B
P2-DIMM1A
P2-DIMM1B
Slot6 PCI-E 2.0x8
Slot5 PCI-E 2.0x8 in x16
Slot4 PCI-E 2.0 x16
Slot3
PCI 33 MHz
Slot2 PCI-E x4
J26
Slot1 PCI 33MHz
CPU2
SPEC
BMC/VGA
JPB
CTRL
D1
JPG1
J27J28
BIOS
JBT1
USB6/7
JUSB3
JPW3
USB4/5
JUSB2
ICH10R
South Bridge
USB3
USB2
J6
CPU1
P1-DIMM1B
P1-DIMM1A
P1-DIMM2B
P1-DIMM2A
P1-DIMM3B
P1-DIMM3A
Intel 5520
North Bridge
LES2
LES1
LSI
1068E
(*X8DT3 Models only)
JPT1
I-SATA1
JWD
I-SATA0
T-SGPIO2
I-SATA5
I-SATA4
T-SGPIO1
I-BUTTON
I-SATA3
I-SATA2
JL1
JPW1
Fan1
SP1
LE1
SI/O
Floppy
J5
SAS4~7
JSM2
(*X8DT3 Models only)
SAS0~3
JSM1
JWOL
JPS2
JPS1
Fan4
Fan7/
CPU1
JOH1
Fan2
JF1
Fan3
JD1
1
1
1
Jumper J 26 is res er ved for inter nal test ing onl y. The manufac turer 's defau lt 2.
setting is on Pins 1 & 2 . Do not c hange t he manuf actur er's d efault se ttin g.
Jumper JPB is reserved for internal use only. Do not change the manufac-3.
turer's default setting.
For IPMI confi guration,4. please refer to the Winbond BMC User's Guide
posted on our website @ http://www.supermicro.com/support/manuals/.
" " indicates the location of Pin 1. Also, refer to Chapter 2 for detailed infor-5.
mation on the onboard components.
When LE1 is on, the onboard power connection is on. Make sure to unplug 6.
the power cables before removing or installing components.
To avoid possible system overheating, be sure to provide adequate airfl ow 7.
to the system.
1-4
Page 13
Chapter 1: Introduction
Quick Reference
JumperDescriptionDefault Setting
JBT1CMOS Clear(See Section 5-10)
2
C1/JI2C2SMB to PCI Slots2-3 (Disabled)
JI
JPG1VGA EnablePins 1-2 (Enabled)
JPL1/JPL2LAN1/2 & LAN 3/4 EnablePins 1-2 (Enabled) (JP2: for LN4 models)
Gigabit Ethernet (RJ45) Ports (See Note 5 on P. 1-4)
LAN
I-SATA0 ~ I-SATA5(Intel South Bridge) SATA Ports
SAS 0~3, 4~7SAS Ports 0~3, 4~7 (X8DT3/-F/-LN4F only)
T-SGPIO-1/T-SGPIO-2Serial General Purpose Input/Output Headers
USB 0/1, 2,3, 4/5, 6/7Universal Serial Bus (USB) Ports
VGAVGA Con nec tor
LEDDescription
D1BMC Heartbeat LED Indicator
LE1Onbo ard St and by LED Ind ica tor
LES1/LES2SAS LEDs (LES1: SAS Heartbeat, LES2: SAS Activity LEDs)
Warning: To prevent damage to the power supply or motherboard, please use a
power supply that contains a 24-pin and two 8-pin power connectors. Be sure to
connect these connectors to the 24-pin (JPW3) and the two 8-pin (JPW1,JPW2)
power connectors on the motherboard. Failure in doing so will void the manufacturer
warranty on your power supply and motherboard.
Two Intel•
full-width Intel QuickPath Interconnect links with a total of up to 51.2 GB/s Data
Transfer Rate (6.4 GB/s per direction)
®
5500 Series (LGA 1366) processors, each processor supporting two
Memory
Twelve 240-pin DIMM sockets support up to 96 GB of DDR3 Registered ECC •
Memory (See Section 2-4 in Chapter 2 for DIMM Slot Population.)
Chipset
Intel 5520 chipset, including: the 5520 (North Bridge) and the ICH10R (South •
Bridge).
Expansion Slots
One PCI-E 2.0 x16 slot (Slot 4) (X8DTi/X8DTi-F only)•
Three PCI-E 2.0 x8 (in x16) slots (Slot 5/Slot 6, and Slot 4 for X8DT3/X8DT3-F/•
X8DTi/3-LN4 only)
One PCI-E x4 slot (Slot 2) or Two PCI-E 2.0 x8 slots (for X8DTi/ X8DTi-F)
•
Two 32-bit PCI 33 slot (Slot 1 and Slot 3)•
BIOS
32 Mb AMI SPI Flash ROM•
PCI 2.2, ACPI 1.0/2.0/3.0, Plug and Play (PnP), DMI 2.3, Wakeup, USB Key-•
board support, and SMBIOS 2.3
PC Health Monitoring
Onboard voltage monitors for CPU1 Vcore/CPU2 Vcore, CPU1 DIMM/CPU2 •
DIMM, 1.5V, 3.3Vcc (V), 3.3V SB (V), 12Vcc (V), 5Vin, and Battery Voltage.
Fan status monitor with fi rmware control
•
CPU/chass is temper ature moni tors•
Platfo rm Enviro nment Co ntrol Inte rf ace (PECI) read y•
Ther mal Mo nitor 2 ( TM2) supp or t•
CPU fan auto - of f in sle ep mode•
CPU slow- dow n on tempe rature over heat•
Pulse Wi dth Mo dulati on (PW M) Fan Contr ol •
CPU ther mal tr ip supp or t for pro ces sor pr otecti on, power L ED•
Power-up mod e cont rol for r ecover y fr om AC power l oss•
Auto- switc hing vol tage r egulato r for CPU c ore s•
System over heat /Fan Fail LED I ndic ator and c ontr ol•
Chassis i ntrus ion detec tion•
1-6
Page 15
Chapter 1: Introduction
System re sourc e aler t vi a Super o Doc tor III•
ACPI Features
Slow blinking LED for suspend state indicator•
Main switch override mechanism•
ACPI Pow er Ma nag eme nt•
Keyboard Wakeup from Soft-off •
Onboard I/O
Intel ICH10R supports six SATA2 ports (with RAID0, RAID1, RAID10, RAID5 •
supported in the Windows OS Environment) (Note 1)
LN4F) (Note 2)
Intel 82576EB dual-port Gigabit Ethernet controllers support Giga-bit LAN
•
por ts (an addit ional 8 2576EB is ava ilabl e on the X8 DT3/ i- LN4F o nly)
One fl oppy por t inter fac e and t wo COM po rt s (1 header, 1 port)
•
One VGA Por t supp or ted by the W PCM4 50 BM C Cont rolle r•
PS/2 mo use and PS /2 keyboa rd por ts•
Up to eigh t USB 2.0 (Uni versal S erial Bus) (2 Back panel USB Po rts, 2 Fro nt •
USB Hea ders , and 2 Type A Header s)
Super I/ O: Winbo nd W83 627HG
•
IPMI 2.0 w ith fu ll K VM supp or t (X8DT 3/i -F/- LN4F o nly) (Note 3)•
Other
Wake-on-LAN (WOL)•
Console redirection•
Onboa rd Fan Spee d Contr ol by Ther mal Ma nagem ent via BI OS•
CD/Diskette Utilities
BIOS fl ash upgrade utility and device drivers•
Dimensions
Ext . ATX 12.00" (L) x 13.00 " (W ) (304. 80 mm x 3 30. 20 mm)•
Note 1: For more information on SATA HostRAID confi guration, please
refer to the Intel SATA HostRAID User's Guide posted on our website @
http://www.supermicro.com/support/manuals/.
Note 2: For more information on LSI SAS RAID confi guration, please refer
to the LSI MegaRAID User's Guide posted on our website @ http://www.
supermicro.com/support/manuals/.
Note 3: For more information on IPMI confi guration, please refer to the
Embedded IPMI User's Guide posted on our website @ http://www.supermicro.com/support/manuals/.
Note: This is a general block diagram. Please see the previous Motherboard Features pages for details on the features of each motherboard.
MS
KB
COM1
External
Block Diagram of the 5520 Platform
1-8
COM2
internal
Page 17
Chapter 1: Introduction
1-3 Chipset Overview
Built upo n the capabili ty of the Intel 5 520 platfor m, the X8DT3/ X8DTi/X8 DT3- F/
X8DTi- F/X8DT3 -LN4F/X8 DTi-LN4 F motherboa rd provides the p erfor mance and
feature set r equired for dual -proce ssor-based hig h-end syste ms with confi gura-
tion optimized for workstations, High Performance Computing (HPC) systems,
and intensi ve applicati ons. The 5520 p latfor m consists of t he 550 0 Series (LGA
1366) processor, the 5520 (North Bridge), and the ICH10R (South Bridge). With
the Quic kPath Inter conne ct (QPI) contr oller bui lt in, the 5 520 platf orm is th e fi rst
dual-processing platform that offers the next generation point-to-point system
interco n n ect interface to replace the curre nt Fro nt S ide Bus Technology, substantially enhancing system performance with increased bandwidth and scalability.
The 5520 North Bridge connects to each processor through an independent QuickPath Interconnect link. Each link consists of 20 pairs of unidirectional differential
lanes for data transferring in addition to a di fferential f orwarded clock. A full-width
QuickPath interconnect link pair provides 84 signals. Each processor supports two
Quick Path links, o ne goin g to the othe r proc esso r and the ot her to th e 5520.
The 5520 platform supports up to 36 PCI Express Gen2 lanes, peer-to-peer read
and write transactions. The ICH1 0R provides up to 6 PCI-Express ports, six SATA
por ts and 10 US B conn ecti ons.
In additi on, the 5 520 plat for m also of fers a w ide ran ge of R AS (Relia bilit y, Availability and Serviceability) features. These features include memory interface ECC,
x4/x8 S ingle Devic e Data C orrec tion (SDD C), Cyclic Redund ancy Chec k (CRC),
parity protection, out-of-band register access via SMBus, memory mirroring,
memor y spa ring, a nd Hot- plug su ppor t on t he PCI -E xpre ss Inter f ace.
Main Features of the 5500 Series Processor and the 5520
Chipset
Four processor cores in each processor with 8MB shared cache among cores•
Two full-width Intel QuickPath interconnect links, up to 6.4 GT/s of data transfer •
rate in each direction
BIOS provides a setting for you to determine how the system will respond when
AC power is lost and then restored to the system. You can choose for the system
to remain powered off (in which case you must hit the power switch to turn it back
on) or for it to automatically return to a power- on state. See the Advanced BIOS
Setup section to change this setting. The default setting is Last State.
1-5 PC Health Monitoring
This section describes the PC health monitoring features of the X8DT3/X8DTi/
X8DT3-F/X8DTi-F/X8DT3-LN4F/X8DTi-LN4F. All have an onboard System Hardware Monitor chip that supports PC health monitoring. An onboard voltage monitor
will scan these onboard voltages continuously: CPU1 Vcore/CPU2 Vcore, CPU1
DIMM/CPU2 DIMM, 1.5V, 3.3Vcc (V), 3.3V SB (V), 12Vcc (V), 5Vin, and Battery
Voltage. Once a voltage becomes unstable, a warning is given or an error message is sent to the screen. Users can adjust the voltage thresholds to defi ne the
sensitivity of the voltage monitor.
Fan Status Monitor with Firmware Control
The PC health monitor can check the RPM status of the cooling fans. The onboard
CPU and chassis fans are controlled by Thermal Management via BIOS (under
Hardware Monitoring in the Advanced Setting).
Environmental Temperature Control
The thermal control sensor monitors the CPU temperature in real time and will turn
on the thermal control fan whenever the CPU temperature exceeds a user-defi ned
threshold. The overheat circuitry runs independently from the CPU. Once it detects
that the CPU temperature is too high, it will automatically turn on the thermal fan
control to prevent any overheat damage to the CPU. The onboard chassis thermal
circuitry can monitor the overall system temperature and alert users when the chassis temperature is too high.
To avoid possible system overheating, please be sure to provide adequate
airfl ow to your system.
System Resource Alert
This feature is available when used with Supero Doctor III in the Win dows OS
1-10
Page 19
Chapter 1: Introduction
environment or used with Supero Doctor II in Linux. Supero Doctor is used to
notif y the user of cer tain system events. For example, you can also confi gure
Supero Doctor to provide you with warnings when the system temperature, CPU
temperat ures, volt ages a nd fan spe eds go beyon d a pre- defi ned range.
1-6 ACPI Features
ACPI stands for Advanced Confi guration and Power Interface. The ACPI specifi ca-
tion defi nes a fl exible and abstract hardware interface that provides a standard
way to integrate power management features throughout a PC system, including
its hardware, operating system and application software. This enables the system
to automatically turn on and off peripherals such as CD-ROMs, network cards, hard
disk drives and printers.
In addition to enabling operating system-directed power management, ACPI
provides a generic system event mechanism for Plug and Play and an operating
system-independent interface for confi guration control. ACPI leverages the Plug
and Play BIOS data structures while providing a processor architecture-independent
implementation that is compatible with the Windows XP/2003/2008/Vista Operating
System.
Slow Blinking LED for Suspend-State Indicator
When the CPU goes into a suspend state, the chassis power LED will start blinking
to indicate that the CPU is in suspend mode. When the user presses any key, the
CPU will wake-up and the LED will automatically stop blinking and remain on.
Main Switch Override Mechanism
When an ATX power supply is used, the power button can function as a system
suspend button to make the system enter a SoftOff state. The monitor will be
suspended and the hard drive will spin down. Pressing the power button again
will cause the whole system to wake-up. During the SoftOff state, the ATX power
supply provides power to keep the required circuitry in the system "alive." In case
the system malfunctions and you want to turn off the power, just press and hold
the power button for 4 seconds. This option can be set in the Power section of the
BIOS Setup routine.
Wake-On-LAN (WOL)
Wake-On-LAN is defi ned as the ability of a management application to remotely
power up a computer that is powered off. Remote PC setup, up-dates and asset
tracking can occur after hours and on weekends so that daily LAN traffi c is kept
to a minimum and users are not interrupted. The motherboard has a 3-pin header
(WOL) to connect to the 3-pin header on a Network Interface Card (NIC) that has
WOL capability. In addition, an onboard LAN controller can also support WOL
without any connection to the WOL header. The 3-pin WOL header is to be used
with a LAN add-on card only.
Note: Wake-On-LAN requires an ATX 2.01 (or above) compliant power
supply.
1-7 Power Supply
As with all computer products, a stable power source is necessary for proper and
reliable operation. It is even more important for processors that have high CPU
clock rates.
The X8DT3/X8DTi/X8DT3-F/X8DT i-F/X8DT3-LN4F/X8DT i-LN4F can accommodate
24-pin ATX power supplies. Although most power supplies generally meet the
specifi cations required by the CPU, some are inadequate. In addition, the two 12V
8-pin power connections are also required to ensure adequate power supply to the
system. Also your power supply must supply 1.5A for the Ethernet ports.
Warning: To prevent damage to the power supply or motherboard, please
use a power supply that contains a 24-pin and two 8-pin power connectors.
Be sure to connect these connectors to the 24-pin (JPW3) and the two
8-pin (JPW1,JPW2) power connectors on the motherboard for adequate
power supply to your system. Failure in doing so will void the manufacturer
warranty on your power supply and motherboard.
It is strongly recommended that you use a high quality power supply that meets ATX
power supply Specifi cation 2.02 or above. It must also be SSI compliant (For more
information, please refer to the web site at http://www.ssiforum.org/). Additionally, in
areas where noisy power transmission is present, you may choose to install a line
fi lter to shield the computer from noise. It is recommended that you also install a
power surge protector to help avoid problems caused by power surges.
1-8 Super I/O
The disk drive adapter functions of the Super I/O chip include a fl oppy disk drive
controller that is compatible with industry standard 82077/765, a data separator,
write pre-compensation circuitry, decode logic, data rate selection, a clock generator, drive interface control logic and interrupt and DMA logic. The wide range of
functions integrated onto the Super I/O greatly reduces the number of components
required for interfacing with fl oppy disk drives. The Super I/O supports 360 K, 720
K, 1.2 M, 1.44 M or 2.88 M disk drives and data transfer rates of 250 Kb/s, 500 Kb/s
or 1 Mb/s. It also provides two high-speed, 16550 compatible serial communication
ports (UARTs). Each UART includes a 16-byte send/receive FIFO, a programmable
1-12
Page 21
Chapter 1: Introduction
baud rate generator, complete modem control capability and a processor interrupt
system. Both UARTs provide legacy speed with baud rate of up to 115.2 Kbps
as well as an advanced speed with baud rates of 250 K, 500 K, or 1 Mb/s, which
support higher speed modems.
The Super I/O provides functions that comply with ACPI (Advanced Confi guration
and Power Interface), which includes support of legacy and ACPI power management through an SMI or SCI function pin. It also features auto power management
to reduce power consumption.
1-9 Overview of the Winbond WPCM450 Controller (For
X8DT3/i-F/X8DT3/i-LN4F Only)
The Winbond WPCM450 Controller is a Baseboard Management Controller (BMC)
that supports the 2D/VGA-compatible Graphics Core with the PCI interface,
Virtual Media, and Keyboard/Video/Mouse Redirection (KVMR) modules. With
blade-oriented Super I/O capability built-in, the WPCM450 Controller is ideal for
legacy-reduced server platforms.
The WPCM450 interfaces with the host system via a PCI interface to communicate
with the Graphics core. It supports USB 2.0 and 1.1 for remote keyboard/mouse/
virtual media emulation. It also provides LPC interface to control Super IO functions.
The WPCM450 is connected to the network via an external Ethernet Phy module.
The WPCM450 communicates with onboard components via six SMBus interfaces,
fan control, and Platform Environment Control Interface (PECI) buses.
Electrostatic Discharge (ESD) can damage electronic com ponents. T o prevent damage to your system board, it is important to handle it very carefully. The following
measures are generally suffi cient to protect your equipment from ESD.
Precautions
Use a grounded wrist strap designed to prevent static discharge.•
Touch a grounded metal object before removing the board from the antistatic •
bag.
Handle the board by its edges only; do not touch its components, peripheral
•
chips, memory modules or gold contacts.
When handling chips or modules, avoid touching their pins.
•
Put the motherboard and peripherals back into their antistatic bags when not •
in use.
For grounding purposes, make sure your computer chassis provides excellent
•
conductivity between the power supply, the case, the mounting fasteners and
the motherboard.
Use only the correct type of onboard CMOS battery as specifi ed by the
•
manufacturer. Do not install the onboard battery upside down to avoid possible
explosion.
Unpacking
The motherboard is shi p ped in antistati c p ackaging to avoid st atic damage. When
unpacking the board, make sure the person handling it is static protected.
All motherboards have standard mounting holes to fi t different types of chassis.
Make sure that the locations of all the mounting holes for both motherboard and
chassis match. Although a chassis may have both plastic and metal mounting
fasteners, metal ones are highly recommended because they ground the motherboard to the chassis. Make sure that the metal standoffs click in or are screwed in
tightly. Then use a screwdriver to secure the motherboard onto the motherboard
tray. Note: Some components are very close to the mounting holes. Please take
precautionary measures to prevent damage to these components when installing
the motherboard to the chassis.
Tools Needed
1. Phillips Screwdriver
Locations of Mounting Holes
2. Pan head #6 screws
Installation Instructions
Install the IO shield into the chassis. 1.
Locate the mounting holes on the motherboard. Refer to the layout above for 2.
mounting hole locations.
Locate the matching mounting holes on the chassis. Align the mounting holes 3.
on the motherboard against the mounting holes on the chassis.
Install standoffs in the chassis as needed.4.
Install the motherboard into the chassis carefully to avoid damage to mother-5.
board components.
Warning: To avoid damaging the motherboard and its components, please
do not apply any force greater than 8 lb/sq.in (8 lbs. per square inch) when
installing a screw into a mounting hole.
X8DT3/i Series
Insert a Pan head #6 screw into a mounting hole on the motherboard and its 6.
matching mounting hole on the chassis, using a Phillips screwdriver.
Repeat Step 4 to insert #6 screws to all mounting holes.7.
Make sure that the motherboard is securely placed on the chassis.8.
2-2
Page 25
2-3 Processor and Heatsink Installation
!
When handling the processor package, avoid placing direct pressure on
the label area of the fan.
Notes:
Always connect the power cord last and always remove it before adding, re-1.
moving or changing any hardware components. Make sure that you install the
processor into the CPU socket before you install the CPU heatsink.
Make sure to install the motherboard into the chassis before you install the 2.
CPU heatsink and heatsink fans.
When purchasing a 5500 Series processor or when receiving a motherboard 3.
with a 5500 Series processor pre-installed, make sure that the CPU plastic
cap is in place, and none of the CPU pins are bent; otherwise, contact the
retailer immediately.
Chapter 2: Installation
Refer to the M B Features S ecti on for mo re deta ils on CPU s uppor t.4.
Installing an LGA 1366 Processor
Press the socket clip to release 1.
the load plate, which covers the
CPU socket, from its locking
position.
Gently lift the socket clip to 2.
open the load plate.
Hold the plastic cap at its north 3.
and south center edges to remove it from the CPU socket.
Socket Clip
Plastic Cap
Load Plate
Hold the north & south edges of
the plastic cap to remove it
After removing the plastic cap, 1.
using your thumb and the index
fi nger, hold the CPU at the
CPU CPU SocketLoad Plate
north and south center edges.
Align the CPU key, the semi-2.
circle cutout, against the socket
key, the notch below the gold
color dot on the side of the
socket.
Once both the CPU and the 3.
socket are aligned, carefully
lower the CPU straight down
Socket Keys
into the socket. (Do not rub the
CPU against the surface of the
socket or its pins to avoid damaging the CPU or the socket.)
With the CPU inside the socket, 4.
inspect the four corners of the
CPU to make sure that the CPU
is properly installed.
Once the CPU is securely 5.
seated on the socket, lower the
CPU load plate to the socket.
Use your thumb to gently push 6.
the socket clip down to the clip
lock.
Warning: Please save th e
plastic cap. The motherboard must be shipped
with the plastic cap properly ins tal led to p rotec t the
CPU socket pins. Shipment without the plastic
cap properly installed will
cause damage to the socket pins.
CPU Keys
2-4
Page 27
Installing a CPU Heatsink
Do not apply any thermal 1.
grease to the heatsink or the
CPU die because the required
amount has already been applied.
Chapter 2: Installation
Place the heatsink on top of the 2.
CPU so that the four mounting
holes are aligned with those on
the retention mechanism.
Install two diagonal screws (ie 3.
the #1 and t he #2 s crews) and
tighten them until just snug
(-do not f ully tig hten the sc rews
to avoid possible damage to
the CPU.)
Screw#1
Screw#1
Install Screw#1
Screw#2
Screw#2
Finish the installation by fully 4.
tightening all four screws.
Warni ng: We do not recommend that the CPU or the heatsink be removed. However, if you do need to remove the heatsink, please follow
the inst ructions be low to uninstall th e heatsink and prevent da mage to
the CPU or ot her co mpone nts.
Unplug the power cord from the 1.
power supply.
Disconnect the heatsink fan 2.
wires from the CPU fan header.
Using a screwdriver, loosen and 3.
remove the heatsink screws
from the motherboard in the sequence as show in the picture
on the right.
Using a screwdriver to
remove Screw#1
Hold the heatsink as shown 4.
in the picture on the right and
gently wriggle the heatsink to
loosen it from the CPU. (Do not
use excessive force when wriggling the heatsink.)
Once the CPU is loosened, 5.
remove the heatsink from the
CPU socket.
To reinstall the CPU and the 6.
heatsink, clean the surface of
the CPU and the heatsink to get
rid of the old thermal grease.
Reapply the proper amount of
thermal grease on the surface
before reinstalling them on the
motherboard.
Remove Screw#2
2-6
Page 29
Chapter 2: Installation
2-4 Memory Installation
Note: Check the S uper micro we b site for r ecom mende d memor y mo dules .
CAUTION
Exercise extreme care when installing or removing DIMM
module s to prevent any po ssib le damag e. Also n ote that th e
memor y is i nterl eaved to imp rove per fo rman ce (See ste p 1).
DIMM Installation
Insert the desired number of DIMMs into the memory slots, starting with 1.
DIMM #P1-DIMM1A. When populating two DIMM modules within a channel,
always start with Bank1 fi rst. For optimal memory performance, please install
a pair (or pairs) of memory modules of the same type and same speed at a
time with the maximum of 12 modules. (See the Memory Installation Table on
Page 2-8.)
Insert each DIMM module vertically into its slot. Pay attention to the notch 2.
along the bottom of the module to prevent inserting the DIMM module incorrectly.
Gently press down on the DIMM module until it snaps into place in the slot. 3.
Repeat for all modules.
DIMM DDR3
Note: Notch
should align
with the
receptive point
on the slot
3
X8DT3/i Series
To Remove:
Use your thumbs
to gently push
the release tabs
near both ends of
the module. This
should release it
from the slot.
To In s ta l l : In ser t mo dule ve r tic ally a nd pre ss do wn unt il it
snaps in to plac e. Pay at tent ion to t he ali gnme nt notc h at
the bottom.
The X8DT3/X8DTi/X8DT3-F/X8DTi-F/X8DT3-LN4F/X8DTi-LN4F supports up to 96
GB Registered ECC DDR3 1333 MHz/1066 MHz/800 MHz in 12 DIMMs. Please
note that Memory Speed support is also depending on the type of CPU used in
the motherboard.
DIMM Module Population Confi guration
For memor y to wor k pro perl y, follow the tab les be low for me mor y inst allati on:
DIMM Population Table
DIMM
Slots per
Channel
21Reg. DDR3 ECC800,1066,1333SR or DR
21Reg. DDR3 ECC800,1066QR
22Reg. DDR3 ECC800,1066Mixing SR, DR
22Reg. DDR3 ECC800Mixing SR, DR,QR
The I/O p ort s are col or cod ed in co nforma nce wit h the PC 9 9 speci fi cation. See
the pic ture be low for t he co lors a nd loc atio ns of the var ious I /O por t s.
1. Back Panel Connectors/IO Ports
11
X8DT3/i Series
Back Panel I/O Port Locations and Defi nitions
Back Panel Connectors
Keyboard (Purple)1.
PS/2 Mouse (Green)2.
Back Panel USB Port 03.
Back Panel USB Port 14.
Dedicated LAN (X8DT3/i-F/ X8DT3/i-LN4F only)5.
COM Port 1 (Turquoise)6.
VGA (Blue) 7.
Gigabit LAN 18.
Gigabit LAN 3 (for X8DT3-LN4F/X8DTi-LN4F only)9.
Gigabit LAN 210.
Gigabit LAN 4 (for X8DT3-LN4F/X8DTi-LN4F only)(See 11.
Sect ion 2- 5 for d etail s.)
10
2-10
Page 33
Chapter 2: Installation
1
2
ATX PS/2 Keyboard and PS/2
Mouse Ports
The ATX PS/2 keyboard and PS/2
mouse are located next to the Back
Panel USB Ports 0~1 on the motherboard. See the table at right for pin
defi nitions.
Two Universal Serial Bus ports (USB
0 and USB 1) are located on the I/O
back panel. Additionally, six USB connections (USB 2, 3, 4/5, 6/7) on the
motherboard to provide front chassis
access. (Cables are not included).
See the tables on the right for pin
defi nitions.
Two COM connections (COM1 & COM2)
are located on the motherboard. COM1
is located on the Backplane IO panel.
COM2 is located next to the onboard
battery to provide additional onboard
serial connection support. See the table
on the right for pin defi nitions.
Video Connector
A Video (VGA) connector is located
next to COM Port1 on the IO backplane. This connector is used to provide
video display. Refer to the board layout
below for the location.
Two Ethernet ports (LAN 1/LAN2) are
located at on the IO backplane. In
addition, LAN 3/LAN4 are supported
on the X8DT3/i-LN4F. A dedicated
LAN is also located on the X8DT3/i-F/
X8DT3/i-LN4F to provide KVM support for IPMI 2.0. All these ports accept RJ45 type cables. (Note: Please
refer to the LED Indicator Section for
LAN LED information.)
LAN Ports
Pin Defi nition
Pin# Defi nition
1P2V5SB10SGND
2TD0+11Act LED
3TD0-12P3V3SB
4TD1+13Link 100 LED
JF1 contains header pins for various buttons and indicators that are normally located on a control panel at the front of the chassis. These connectors are designed
specifi cally for use with Supermicro server chassis. See the fi gure below for the
descriptions of the various control panel buttons and LED indicators. Refer to the
following section for descriptions and pin defi nitions.
The non-maskable interrupt button
header is located on pins 19 and 20
of JF1. Refer to the table on the right
for pin defi nitions.
Power LED
The Power LED connection is located
on pins 15 and 16 of JF1. Refer to the
table o n the ri ght for p in defi nitions.
NMI Button
Pin Defi nitions (JF1)
Pin# Defi nition
19Control
20Ground
Power LED
Pin Defi nitions (JF1)
Pin# Defi nition
15+5V
16Ground
X8DT3/i Series
2-16
A. NMI
B. PWR LED
Ground
X
B
Power LED
HDD LED
NIC1 LED
NIC2 LED
OH/Fan Fail LED
PWR Fail LED
Ground
Ground
1920
A
NMI
X
Vcc
Vcc
Vcc
Vcc
Vcc
Vcc
Reset
Reset Button
Power Button
PWR
2
1
Page 39
HDD LED
Chapter 2: Installation
The HDD LED connection is located
on pins 13 and 14 of JF1. Attach a
hard drive LED cable here to display
disk activity (for any hard drive activities on the system, including SAS,
Serial ATA and IDE). See the table on
the right for pin defi nitions.
NIC1/NIC2 LED Indicators
The NIC (Network Interface Controller) LED connection for GLAN port 1 is
located on pins 11 and 12 of JF1, and
the LED connection for GLAN Port 2
is on Pins 9 and 10. Attach the NIC
LED cables to display network activity .
Refer to the table on the right for pin
defi nitions.
Connect an LED Cable to the OH/
Fan Fail conn ection o n pins 7 and 8
of JF1 to provide ad vanc ed wa rn ing s
of chass is overhe ating or fa n failure.
Refer to the t able o n the ri ght for p in
defi nitions.
Power Fail LED
The Power Fail LED connection is
locate d on pins 5 and 6 of JF1. Refer to the table on the right for pin
defi nitions.
OH/Fan Fail LED
Pin Defi nitions (JF1)
Pin# Defi nition
7Vcc
8Ground
OH/Fan Fail Indicator
Status
State Defi nition
OffNormal
OnOverheat
Flash-
ing
Fan Fail
PWR Fail LED
Pin Defi nitions (JF1)
Pin# Defi nition
5Vcc
6Ground
X8DT3/i Series
2-18
A. OH/Fan Fail LED
B. PWR Supply Fail
Ground
X
Power LED
HDD LED
NIC1 LED
NIC2 LED
OH/Fan Fail LED
A
B
PWR Fail LED
Ground
Ground
1920
NMI
X
Vcc
Vcc
Vcc
Vcc
Vcc
Vcc
Reset
Reset Button
Power Button
PWR
2
1
Page 41
Reset Button
Chapter 2: Installation
The Reset Button connection is located
on pins 3 and 4 of JF1. Attach it to a
hardware reset switch on the computer
case. Refer to the table on the right for
pin defi nitions.
Power Button
The Power Button connection is located
on pins 1 and 2 of JF1. Momentarily contacting both pins will power on/off the system. This button can also be confi gured
to function as a suspend button (with a
setting in the BIOS - see Chapter 4). To
turn off the power when set to suspend
mode, press the button for at least 4
seconds. Refer to the table on the right
for pin defi nitions.
A 24-pin main power supply connector(JPW3)
and two 8-pin CPU PWR connectors (JPW1/
JPW2) on the motherboard. These power
connectors meet the SSI EPS 12V specifi -
cation. In addition to the 24-pin ATX power
connector, the 12V 8-pin CPU PWR connectors at JPW1/JPW2 must also be connected
to your power supply. See the table on the
right for pin defi nitions.
Warning: To prevent damage to
the power supply or motherboard,
please use a power supply that
contains a 24-pin and two 8-pin
power connectors. Be sure to
connect these connectors to the
24-pin (JPW3) and the two 8-pin
(JPW1,JPW2) power connectors
on the motherboard. Failure in doing so will void the manufacturer
warranty on your power supply and
motherboard.
This motherboard has six chassis/system
fan headers (Fan1 to Fan6) and two CPU
fans (Fan7/Fan8) on the motherboard. All
these 4-pin fans headers are backward
compatible with the traditional 3-pin fans.
However, fan speed control is available
for 4-pin fans only. The fan speeds are
controlled by Thermal Management via
Hardware Monitoring in the Advanced
Setting in the BIOS. (The Default setting
is Disabled.) See the table on the right for
pin defi nitions.
A Chassis Intrusion header is located
at JL1 on the motherboard. Attach an
appropriate cable from the chassis to
inform you of a chassis intrusion when
the chassis is opened.
KB/MOUSE
USB 0/1
COM1
VGA
LAN1
LAN3
LAN2
LAN4
LAN
CTRL
LAN
CTRL
(X8DT3/i-LN4F)
X8DT3/i Series
Battery
COM2
Fan5
Dedicated LAN
(X8DT3/i-F/-LN4F only)
Fan8/
H
CPU2 FAN
JLAN1
JLAN2
JI2C1
JI2C2
JPL1
JPL2
Fan6
Slot6 PCI-E 2.0x8
Slot5 PCI-E 2.0x8 in x16
Slot4 PCI-E 2.0 x16
Slot3
Slot2 PCI-E x4
Slot1 PCI 33MHz
JPW2
PCI 33 MHz
SPEC
BMC/VGA
CTRL
JPB
JPW3
BIOS
JBT1
D1
USB4/5
USB6/7
JPG1
J27J28
JUSB3
P2-DIMM3A
P2-DIMM3B
P2-DIMM2A
P2-DIMM2B
P2-DIMM1A
P2-DIMM1B
CPU2
J26
JUSB2
ICH10R
South Bridge
USB3
J6
Intel 5520
North Bridge
T-SGPIO1
T-SGPIO2
I-BUTTON
I-SATA5
I-SATA3
USB2
I-SATA4
I-SATA2
P1-DIMM1B
P1-DIMM1A
P1-DIMM2B
P1-DIMM2A
P1-DIMM3B
P1-DIMM3A
CPU1
LES2
(*X8DT3 Models only)
I-SATA1
I-SATA0
1068E
Chassis Intrusion
Pin Defi nitions (JL1)
Pin# Defi nition
1Intrusion Input
2Ground
A. Fan 1
JPW1
A
Fan1
B. Fan 2
C. Fan 3
Fan7/
CPU1
SP1
JOH1
JD1
B
Fan2
LE1
1
JF1
1
Fan3
C
SI/O
Floppy
1
J5
LES1
SAS4~7
JL1
(*X8DT3 Models only)
SAS0~3
JPS2
JPS1
I
JSM2
JSM1
JWOL
Fan4
LSI
JPT1
JWD
D. Fan 4
E. Fan 5
F. Fan 6
G. Fan 7 (CPU1 Fan)
H. Fan 8 (CPU2 Fan)
I. Chassis Intrusion
The Internal Speaker, located at SP1,
can be used to provide audible indications for various beep codes. See the
table on the right for pin defi nitions.
Refer to the layout below for the locations of the Internal Buzzer (SP1).
Power LED/Speaker
On the JD1 header, pins 1-3 are used
for power LED indication, and pins 4-7
are for the speaker. See the table on
the right for speaker pin defi nitions.
Please note that the speaker connector pins (4-7) are for use with an
external speaker. If you wish to use
the onboard speaker, you should close
pins 6-7 with a jumper.
Internal Buzzer (SP1)
Pin Defi nition
Pin# Defi nitions
Pin 1Pos. (+)Beep In
Pin 2Neg. (-)Alarm
The Wake-On-LAN header is located
at JWOL on the motherboard. You
must also have a LAN card with a
Wake-On-LAN connector and a cable
to use this feature. See the table on
the right for pin defi nitions.
Overheat LED/Fan Fail (JOH1)
The JOH1 header is used to connect
an LED indi c ato r to p rov i de wa r ni ng s
of chass is overhe ating or fa n failure.
This LED will blink when a fan failure
occu r s. Refe r to th e t abl e on r i ght f or
pin defi nitions.
Two SGPIO (Serial-Link General
Purpose Input/Output) headers
(T-SGPIO-1/T-SGPIO-2) are located
the motherboard. These headers
support serial link interfaces for the
onboard SATA and SAS connectors.
See the table on the right for pin defi ni-
tions. Refer to the board layout below
for the location.
I-Button (Optional for X8DT3/-F/
LN4F only)
An onboard I-Button, located next to
USB Ports 2~3, is an 1-wire computer
chip enclosed in a durable stainless
steel can. I-Button stores instructions, provides electronic interface
and allows HostRAID to operate with
Mega-RAID fi rmware.
KB/MOUSE
USB 0/1
COM1
VGA
Fan8/
CPU2 FAN
LAN1
LAN3
LAN2
LAN4
LAN
CTRL
LAN
CTRL
(X8DT3/i-LN4F)
X8DT3/i Series
Battery
COM2
JPL2
Fan5
Dedicated LAN
(X8DT3/i-F/-LN4F only)
JLAN1
JLAN2
JI2C1
JI2C2
JPL1
Fan6
Slot6 PCI-E 2.0x8
Slot5 PCI-E 2.0x8 in x16
Slot4 PCI-E 2.0 x16
Slot3
Slot2 PCI-E x4
Slot1 PCI 33MHz
JPW2
PCI 33 MHz
J26
P2-DIMM3A
P2-DIMM3B
P2-DIMM2A
P2-DIMM2B
P2-DIMM1A
P2-DIMM1B
JPW3
CPU2
SPEC
BIOS
JBT1
BMC/VGA
CTRL
D1
JPB
USB4/5
USB6/7
JPG1
J27J28
JUSB3
JUSB2
ICH10R
South Bridge
USB3
J6
A
B
T-SGPIO1
T-SGPIO2
I-SATA5
USB2
I-SATA4
I-SATA3
I-SATA2
P1-DIMM1B
P1-DIMM1A
P1-DIMM2B
P1-DIMM2A
P1-DIMM3B
P1-DIMM3A
Intel 5520
North Bridge
C
I-BUTTON
CPU1
LES2
(*X8DT3 Models only)
I-SATA1
I-SATA0
1068E
JPW1
Fan1
B. T-SGPIO-2
C. I-Button (Optional for
A. T-SGPIO-1
Fan7/
CPU1
SP1
JOH1
Fan2
LE1
JF1
Fan3
SI/O
Floppy
J5
LES1
SAS4~7
JL1
JSM2
(*X8DT3 Models only)
SAS0~3
JSM1
JWOL
JPS2
JPS1
Fan4
LSI
JPT1
JWD
X8DT3 models only)
JD1
1
1
1
2-24
Page 47
Chapter 2: Installation
Power SMB (I2C) Connector
Power System Management Bus
2
(I
C) Connector (J6) monitors power
supply, fan and system temperatures.
See the table on the right for pin
defi nitions.
IPMB I2C SMB
A System Management Bus header
for the IPMI slot is located at J5.
Connect the appropriate cable here
to use the IPMB I
To modify the operation of the motherboard, jumpers can be used to choose
between optional settings. Jumpers create
shorts between two pins to change the
function of the connector. Pin 1 is identifi ed
with a square solder pad on the printed
circuit board. See the motherboard layout
pages for jumper locations.
Note: On two pin jumpers,
"Clos ed " me ans t he j ump er i s on
and "O pen" mea ns the ju mper i s
off t he pins.
GLAN Enable/Disable
Use JPL1 to enable or dis able the G LA N
Ports 1 & 2. Use JPL2 to enable or disable
the GLAN Ports 3 & 4 on the X8DT3/iLN4F. See the tables on the right for
jumper settings. The default setting is
Enabled.
3 2 1
3 2 1
Pin 1-2 short
GLAN 1 & 2 Enable
Jumper Settings (JPL1)
Pin# Defi nition
1-2Enabled (default)
2-3Disabled
GLAN 3 & 4 Enable
Jumper Settings (JPL2)
Pin# Defi nition
1-2Enabled (default)
2-3Disabled
KB/MOUSE
USB 0/1
COM1
VGA
LAN1
LAN3
LAN2
LAN4
X8DT3/i Series
Fan8/
CPU2 FAN
LAN
CTRL
LAN
CTRL
(X8DT3/i-LN4F)
Battery
COM2
JPL1
JPL2
Fan6
Fan5
Dedicated LAN
(X8DT3/i-F/-LN4F only)
JLAN1
JLAN2
JI2C1
JI2C2
A
B
JPW2
P2-DIMM3A
P2-DIMM3B
P2-DIMM2A
P2-DIMM2B
P2-DIMM1A
P2-DIMM1B
Slot6 PCI-E 2.0x8
Slot5 PCI-E 2.0x8 in x16
Slot4 PCI-E 2.0 x16
Slot3
PCI 33 MHz
Slot2 PCI-E x4
J26
Slot1 PCI 33MHz
CPU2
SPEC
BIOS
JBT1
BMC/VGA
CTRL
D1
JPB
USB6/7
JPG1
J27J28
JUSB3
A. GLAN 1 &2 Enable
B. GLAN 3 & 4 Enable
X8DT3/i - LN4F on ly)
(For
JUSB2
ICH10R
South Bridge
USB3
J6
CPU1
P1-DIMM1B
P1-DIMM1A
P1-DIMM2B
P1-DIMM2A
P1-DIMM3B
P1-DIMM3A
Intel 5520
North Bridge
LES2
T-SGPIO1
T-SGPIO2
I-BUTTON
(*X8DT3 Models only)
I-SATA3
I-SATA2
I-SATA1
I-SATA0
I-SATA5
USB2
I-SATA4
1068E
JPT1
JPW1
Fan1
Fan7/
CPU1
SP1
JOH1
JD1
Fan2
LE1
1
JF1
1
Fan3
SI/O
Floppy
1
J5
LES1
SAS4~7
JL1
JSM2
(*X8DT3 Models only)
SAS0~3
JSM1
JWOL
JPS2
JPS1
Fan4
LSI
JWD
JPW3
USB4/5
2-26
Page 49
Chapter 2: Installation
CMOS Clear
JBT1 is used to clear CMOS. Instead of pins, this "jumper " consists of c ontact
pads to prevent t he accident al clearin g of CMOS. To clear CMOS , use a metal
objec t such as a sma ll screwdr iver to touc h both pad s at the same t ime to shor t
the co nnec ti on. A lways rem ove the AC p ower c ord f rom t he syste m befo re cl earing CMOS.
Note: For an ATX power supply, you must completely shut down the system, remove the AC power cord and then short JBT1 to clear CMOS.
Watch Dog Enable/Disable
Watch Dog (JWD) is a syste m monitor th at
can reb oot t he sys tem w hen a s of tware ap plicat ion han gs. Clo se Pins 1-2 to res et the
system if an app lication ha ngs. Close Pins
2-3 to generate a non-maskable interrupt
signal for the application that hangs. See the
table on the right for jumper settings. Watch
Dog must also be enabled in the BIOS.
tion. See the table on the right for jumper
settings.
VGA Enable
Jumper JPG1 allows the user to enable
the onboard VGA connector. The default
setting is 1-2 to enable the connection.
See the table on the right for jumper
settings.
SAS Enable/Disable (X8DT3/
X8DT3-F/X8DT3-LN4F only)
Jumper JPS1 allows you to enable or
disable the onboard SAS connections.
The default setting is Pins 1-2 to enable
the connection. See the table on the right
for jumper settings.
SAS RAID Select (X8DT3/X8DT3-F/
X8DT3-LN4F only)
Jumper JPS2 allows you to select RAID
Confi guration settings for the onboard
SAS connections. See the table on the
right for jumper settings.
Note: For more information on LSI SAS RAID confi guration, please refer
to the LSI MegaRAID User's Guide posted on our website @ http://www.
supermicro.com/support/manuals/.
Two LAN ports (LAN 1/LAN 2) are located
on the IO Backplane of the motherboard.
In addition, LAN3/LAN4 are located on the
X8DT3/i-LN4F. Each Ethernet LAN port
has two LEDs. The yellow LED indicates
activ ity, while the Li nk LED may be gree n,
amber or off to indicate the speed of the
connections. See the tables at right for
more information.
IPMI Dedicated LAN LEDs (X8DT3/i-F/LN4F Only)
In addition to LAN 1/LAN 2, an IPMI Dedicated LAN is also located on the IO Backplane
of the X8DT3/i-F/-LN4F. The amber LED on
the ri ght indica tes activi ty, while the gre en
LED on the l eft indic ates the spee d of the
connection. See the tables at right for more
information.
Activity LED
Link LED
Rear View (when facing the
rear side of the chassis)
LAN 1/LAN 2 Activity LED (Left)
Color Status Defi nition
YellowFlashingActive
LAN 1/LAN 2 Link LED (Right)
LED Color Defi nition
OffNo Connection or 10 Mbps
Green100 Mbps
Amber1 Gbps
Link LED
Color Status Defi nition
Link (Left)Green: Solid100 Mbps
Activity (Right) Amber: BlinkingActive
LED State
LED State
IPMI LAN (F models only)
Activity LED
IPMI LAN Link LED (Left) &
Activity LED (Right)
A
KB/MOUSE
USB 0/1
COM1
VGA
LAN1
LAN3
LAN2
LAN4
X8DT3/i Series
Fan8/
CPU2 FAN
LAN
CTRL
LAN
CTRL
(X8DT3/i-LN4F)
Battery
COM2
JPL1
JPL2
Fan6
Fan5
C
Dedicated LAN
(X8DT3/i-F/-LN4F only)
JLAN1
B
JLAN2
JI2C1
JI2C2
JPW2
P2-DIMM3A
P2-DIMM3B
P2-DIMM2A
P2-DIMM2B
P2-DIMM1A
P2-DIMM1B
Slot6 PCI-E 2.0x8
Slot5 PCI-E 2.0x8 in x16
Slot4 PCI-E 2.0 x16
Slot3
PCI 33 MHz
Slot2 PCI-E x4
J26
Slot1 PCI 33MHz
CPU2
SPEC
BMC/VGA
CTRL
JPB
ICH10R
South Bridge
USB3
J6
CPU1
P1-DIMM1B
P1-DIMM1A
P1-DIMM2B
P1-DIMM2A
P1-DIMM3B
P1-DIMM3A
Intel 5520
North Bridge
LES2
T-SGPIO1
T-SGPIO2
I-BUTTON
(*X8DT3 Models only)
I-SATA3
I-SATA1
-
-
I-SATA5
USB2
-
1068E
JPT1
JPW1
Fan1
SP1
LE1
SI/O
Floppy
J5
LES1
SAS4~7
JL1
JSM2
(*X8DT3 Models only)
SAS0~3
JSM1
JWOL
JPS2
JPS1
Fan4
LSI
JWD
JPW3
BIOS
JBT1
D1
USB4/5
USB6/7
JPG1
J27J28
JUSB3
A. LAN1/2 LEDs
B. LAN3/4 LEDs (X8DT3/iLN4)
B. Dedicated LAN LEDs
Fan7/
CPU1
(X8DT3/i-F/-LN4F)
JOH1
JD1
Fan2
1
JF1
1
Fan3
1
2-30
Page 53
SAS Heartbeat/Activity LED Indicators
Chapter 2: Installation
Two Onboard SAS LED are located on
the motherboard. LES1 is SAS Heartbeat LED, and LES2 is SAS Activity
LED. When LES1 is blinking, SAS connections function normally. When this
LES2 is blinking, SAS connections are
active. See the tables at right for more
information.
BMC Heartbeat LED
A BMC He artbeat LED is l ocated at D1
on the motherboard. When D1 is blinking,
BMC fu nctions nor mally. See the tab les
at right fo r more info rmati on.
Onboard SAS LED Indicators
(LES1/LES2) Settings
LED Color Defi nition
LES1Blinking: SAS: Normal
LES2Blinking: SAS: Active
An Onboard Power LED is located at LE1
on the motherboard. When this LED is lit,
the system is on. Be sure to turn off the
system and unplug the power cord before
Onboard PWR LED (LE1)
Settings
LED Color Defi nition
OffSystem Off (PWR cable
not connected)
GreenSystem Power On
removing or installing components. See
the tabl es at rig ht for mor e infor mation.
KB/MOUSE
USB 0/1
COM1
VGA
LAN1
LAN3
LAN2
LAN4
X8DT3/i Series
Fan8/
CPU2 FAN
LAN
CTRL
LAN
CTRL
(X8DT3/i-LN4F)
Battery
COM2
JPL1
JPL2
Fan6
Fan5
Dedicated LAN
(X8DT3/i-F/-LN4F only)
JLAN1
JLAN2
JI2C1
JI2C2
JPW2
P2-DIMM3A
P2-DIMM3B
P2-DIMM2A
P2-DIMM2B
P2-DIMM1A
P2-DIMM1B
Slot6 PCI-E 2.0x8
Slot5 PCI-E 2.0x8 in x16
Slot4 PCI-E 2.0 x16
Slot3
PCI 33 MHz
Slot2 PCI-E x4
J26
Slot1 PCI 33MHz
CPU2
SPEC
BIOS
JBT1
BMC/VGA
CTRL
D1
JPB
USB6/7
JPG1
J27J28
JUSB3
ICH10R
South Bridge
USB3
J6
CPU1
P1-DIMM1B
P1-DIMM1A
P1-DIMM2B
P1-DIMM2A
P1-DIMM3B
P1-DIMM3A
Intel 5520
North Bridge
LES2
T-SGPIO1
T-SGPIO2
I-BUTTON
(*X8DT3 Models only)
I-SATA3
I-SATA1
-
-
I-SATA5
USB2
-
1068E
JPT1
JPW1
Fan1
Fan7/
CPU1
SP1
JOH1
JD1
Fan2
LE1
A
1
JF1
1
Fan3
SI/O
Floppy
1
J5
LES1
SAS4~7
JL1
JSM2
(*X8DT3 Models only)
SAS0~3
JSM1
JWOL
JPS2
JPS1
Fan4
LSI
JWD
A. Onboard Power LED
JPW3
USB4/5
2-32
Page 55
Chapter 2: Installation
2-9 Floppy Drive, Serial ATA and SAS Connections
Note the fo llowi ng when c onne cting t he fl oppy and hard disk drive cables:
The fl oppy disk drive cable has seven twisted wires.
•
A red mark on a wire typically designates the location of pin 1.•
A single fl oppy disk drive ribbon cable has 34 wires and two connectors to •
provide for two fl oppy disk drives. The connector with twisted wires always
connects to drive A, and the connector that does not have twisted wires always
connects to drive B.
Six Serial ATA Ports (I-SATA0~I -SATA 5) are lo cate d at JS1~JS6 on t he
motherboard. These ports provide
serial-link signal connections, which
are faster than the connections of
Parallel ATA. See the table on the
right fo r pin defi nitions.
SAS Ports (X8DT3/X8DT3-F/
X8DT3-LN4F only)
SAS Ports 0~3, 4~7 , located at JSM1 /
JSM2 , p r ov i d e S e rial- Attache d SCSI
connections on the X8DT3/X8DT3-F/
X8DT3-LN4F. See the layout below
for SAS po r t loc ations .
Note 1: For more information on SATA HostRAID confi guration, please
refer to the Intel SATA HostRAID User's Guide posted on our website @
http://www.supermicro.com/support/manuals/.
Note 2: For more information on LSI SAS RAID confi guration, please
refer to the LSI MegaRAID User's Guide posted on our website @ http://
www.supermicro.com/support/manuals/.
JPW2
P2-DIMM3A
P2-DIMM3B
P2-DIMM2A
P2-DIMM2B
P2-DIMM1A
P2-DIMM1B
Slot6 PCI-E 2.0x8
Slot5 PCI-E 2.0x8 in x16
Slot4 PCI-E 2.0 x16
Slot3
PCI 33 MHz
Slot2 PCI-E x4
J26
Slot1 PCI 33MHz
ICH10R
South Bridge
USB3
J6
CPU1
P1-DIMM1B
P1-DIMM1A
P1-DIMM2B
P1-DIMM2A
P1-DIMM3B
P1-DIMM3A
Intel 5520
North Bridge
LES2
T-SGPIO1
T-SGPIO2
I-BUTTON
(*X8DT3 Models only)
B
I-SATA3
I-SATA1
-
-
A
C
I-SATA5
USB2
-
1068E
JPT1
JPW1
Fan1
Fan7/
CPU1
SP1
JOH1
Fan2
LE1
JF1
Fan3
SI/O
Floppy
J5
LES1
SAS4~7
JL1
JSM2
(*X8DT3 Models only)
SAS0~3
JSM1
JWOL
JPS2
JPS1
Fan4
LSI
JWD
JPW3
CPU2
SPEC
BIOS
JBT1
BMC/VGA
CTRL
D1
JPB
USB4/5
USB6/7
JPG1
J27J28
JUSB3
A. I-SATA0
B. I-SATA1
C. I-SATA2
D. I-SATA3
E. I-SATA4
F. I-SATA5
JD1
G. SAS 0~3 (X8DT3/-F/-LN4F
only)
1
H. SAS 4~7 (X8DT3/-F/-LN4F
1
only)
1
2-34
Page 57
Chapter 3: Troubleshooting
Chapter 3
Troubleshooting
3-1 Troubleshooting Procedures
Use the following procedures to troubleshoot your system. If you have followed all
of the procedures below and still need assistance, refer to the ‘Technical Support
Procedures’ and/or ‘Returning Merchandise for Service’ section(s) in this chapter.
Note: Always disconnect the power cord before adding, changing or installing any
hardware components.
Before Power On
Make sure that there are no short circuits between the motherboard and 1.
chassis.
Disconnect all ribbon/wire cables from the motherboard, including those for 2.
the keyboard and mouse.
Remove all add-on cards.3.
Install CPU 1 fi rst (making sure it is fully seated) and connect the chassis 4.
speaker and the power LED to the motherboard. (Check all jumper settings
as well.)
No Power
Make sure that no short circuits between the motherboard and the chassis.1.
Make sure that all jumpers are set to their default positions.2.
Check that the 115V/230V switch on the power supply is properly set.3.
Turn the power switch on and off to test the system.4.
The battery on your motherboard may be old. Check to verify that it still sup-5.
plies ~3VDC. If it does not, replace it with a new one.
If the power is on but you have no video, remove all the add-on cards and 1.
cables.
Use the speaker to determine if any beep codes exist. Refer to Appendix A 2.
for details on beep codes.
Losing the System’s Setup Confi guration
Make sure that you are using a high quality power supply. A poor quality 1.
power supply may cause the system to lose the CMOS setup information.
Refer to Section 1-6 for details on recommended power supplies.
The battery on your motherboard may be old. Check to verify that it still sup-2.
plies ~3VDC. If it does not, replace it with a new one.
If the above steps do not fi x the Setup Confi guration problem, contact your 3.
vendor for repairs.
Memory Errors
When a No_Memory_Beep_Code is issued by the system, check the following:
Make sure that the DIMM modules are properly and fully installed. 1.
Check if different speeds of DIMMs have been installed. It is strongly recom-2.
mended to use the same RAM speed for all DIMMs in the system.
Make sure you are using the correct type of DDR3 Registered ECC 1333 3.
MHz/1066 MHz/800 MHz SDRAM (recommended by the manufacturer.)
Check for bad DIMM modules or slots by swapping a single module between 4.
all memory slots and check the results.
Make sure that all memory modules are fully seated in their slots. Make sure 5.
to follow the instructions given in Section 2-4 in Chapter 2.
Check the position of the 115V/230V switch on the power supply. 6.
Please follow the instructions given in the DIMM Population Tables listed on 7.
Pages 2-7 and 2-8 to install your memory modules.
3-2
Page 59
Chapter 3: Troubleshooting
3-2 Technical Support Procedures
Before contacting Technical Support, please take the following steps. Also, please
note that as a motherboard manufacturer, Supermicro does not sell directly to endusers, so it is best to fi rst check with your distributor or reseller for troubleshooting
services. They should know of any possible problem(s) with the specifi c system
confi guration that was sold to you.
Please go through the ‘Troubleshooting Procedures’ and 'Frequently Asked 1.
Question' (FAQ) sections in this chapter or see the FAQs on our web site
(
http://www.supermicro.com/support/faqs/) before contacting Technical Sup-
port.
BIOS upgrades can be downloaded from our web site at 2.
supermicro.com/support/bios/
If you still cannot resolve the problem, include the following information when 3.
contacting Supermicro for technical support:
Motherboard model and PCB revision number
•
BIOS release date/version (this can be seen on the initial display when your •
system fi rst boots up)
System confi guration
•
An example of a Technical Support form is on our web site at • (http://www.
supermicro.com/support/contact.cfm).
Distributors: For immediate assistance, please have your account number ready
•
when placing a call to our technical support department. We can be reached by
e-mail at [email protected] or by fax at: (408) 503-8000, option 2.
).
(http://www.
3-3 Frequently Asked Questions
Que sti on: Wh at a re th e var iou s t ype s of m emo r y th at my mo th er boa rd c an
support?
Answer: The X8DT3/X8DTi/X8DT3-F/X8DTi-F/X8DT3-LN4F/X8DTi-LN4F has 12
240-pin DIMM slots that support DDR3 Registered ECC 1333 MHz/1066 MHz/800
MHz SDRAM modules. It is strongly recommended that you do not mix memory
modules of different speeds and sizes. Please follow all memory installation instructions given on Section 2-4 in Chapter 2.
Que stio n: How do I u pda te my BI OS?
Answer: It is recommended that you do not upgrade your BIOS if you are not
experiencing any problems with your system. Updated BIOS fi les are located on
our web site at
warning message and the information on how to update your BIOS on our web
site. Select your motherboard model and download the BIOS fi le to your computer.
Also, check the current BIOS revision and make sure that it is newer than your
BIOS before downloading. You can choose from the zip fi le and the .exe fi le. If you
choose the zip BIOS fi le, please unzip the BIOS fi le onto a bootable USB device.
Run the batch fi le using the format fl ash.bat fi lename.rom from your bootable USB
device to fl ash the BIOS. Then, your system will automatically reboot. Please note
that this process may take a few minutes to complete. Do not be concerned if the
screen is paused for a few minutes.
Warning: Do not shut down or reset the system while updating the BIOS
to prevent possible system boot failure!)
Note: The SPI BIOS chip used on this motherboard cannot be removed.
Send your motherboard back to our RMA Department at Supermicro for
repair.
Question: What's on the CD that came with my motherboard?
Answer: The supplied CD has drivers and programs that are needed for your sys-
tem. Please r eview t h e C D and i ns t al l th e ap pl ications you nee d. A p p lications on
the CD inc lude c hipset d river s for th e Wind ows OS, se cur ity an d audio dr iver s.
3-4 Returning Merchandise for Service
A receipt or copy of your invoice marked with the date of purchase is required before any warranty service will be rendered. You can obtain service by calling your
vendor for a Returned Merchandise Authorization (RMA) number. When returning
to the manufacturer, the RMA number should be prominently displayed on the
outside of the shipping carton, and mailed prepaid or hand-carried. Shipping and
handling charges will be applied for all orders that must be mailed when service
is complete.
For faster service, You can also request a RMA authorization online (http://www.
supermicro.com/support/rma/).
This warranty only covers normal consumer use and does not cover damages incurred in shipping or from failure due to the alternation, misuse, abuse or improper
maintenance of products.
During the warranty period, contact your distributor fi rst for any product problems.
3-4
Page 61
Chapter 4: AMI BIOS
Chapter 4
BIOS
4-1 Introduction
This chapter describes the AMI BIOS Setup Utility for the X8DT3/X8DTi/X8DT3LN4/X8DTi-LN4. The AMI ROM BIOS is stored in a Flash EEPROM and can be
easily updated. This chapter describes the basic navigation of the AMI BIOS Setup
Utility setup screens.
Starting BIOS Setup Utility
To enter the AMI BIOS Setup Utility screens, press the <Delete> key while the
system is booting up.
Note: In most cases, the <Delete> key is used to invoke the AMI BIOS
setup screen. There are a few cases when other keys are used, such as
<F1>, <F2>, etc.
Each main BIOS menu option is described in this manual. The Main BIOS setup
menu screen has two main frames. The left frame displays all the options that can
be confi gured. Grayed-out options cannot be confi gured. Options in blue can be
confi gured by the user. The right frame displays the key legend. Above the key
legend is an area reserved for a text message. When an option is selected in the
left frame, it is highlighted in white. Often a text message will accompany it. (Note:
the AMI BIOS has default text messages built in. Supermicro retains the option to
include, omit, or change any of these text messages.)
The AMI BIOS Setup Utility uses a key-based navigation system called "hot keys".
Most of the AMI BIOS setup utility "hot keys" can be used at any time during the
setup navigation process. These keys include <F1>, <F10>, <Enter>, <ESC>, arrow keys, etc.
Note: Options printed in Bold are default settings.
How To Change the Confi guration Data
The confi guration data that determines the system parameters may be changed by
entering the AMI BIOS Setup utility. This Setup utility can be accessed by pressing
<Del> at the appropriate time during system boot.
4-1
Page 62
X8DT3/X8DTi/X8DT3-LN4/X8DTi-LN4User’s Manual
Starting the Setup Utility
Normally, the only visible Power-On Self-Test (POST) routine is the memory test.
As the memory is being tested, press the <Delete> key to enter the main menu of
the AMI BIOS Setup Utility. From the main menu, you can access the other setup
screens. An AMI BIOS identifi cation string is displayed at the left bottom corner of
the screen below the copyright message.
Warning! Do not upgrade the BIOS unless your system has a BIOS-related
issue. Flashing the wrong BIOS can cause irreparable damage to the
system. In no event shall Supermicro be liable for direct, indirect, special,
incidental, or consequential damages arising from a BIOS update. If you
have to update the BIOS, do not shut down or reset the system while the
BIOS is updating. This is to avoid possible boot failure.
4-2 Main Setup
When you fi rst enter the AMI BIOS Setup Utility , you will enter the Main setup screen.
You can always return to the Main setup screen by selecting the Main tab on the
top of the screen. The Main BIOS Setup screen is shown below.
System Overview: The following BIOS information will be displayed:
System Time/System Date
Use this option to change the system time and date. Highlight System Time or System Date using the arrow keys. Enter new values through the keyboard and press
<Enter>. Press the <Tab> key to move between fi elds. The date must be entered in
Day MM/DD/YY format. The time is entered in HH:MM:SS format. (Note: The time
is in the 24-hour format. For example, 5:30 P.M. appears as 17:30:00.)
4-2
Page 63
Chapter 4: AMI BIOS
Supermicro X8DT3
BIOS Build Version: This item displays the BIOS revision used in your system.
BIOS Build Date: This item displays the date when this BIOS was completed.
AMI BIOS Core Version: This item displays the revision number of the AMI BIOS
Core upon which your BIOS was built.
Processor
The AMI BIOS will automatically display the status of the processor used in your
system:
CPU Type: This item displays the type of CPU used in the motherboard.
•
Speed: This item displays the speed of the CPU detected by the BIOS.•
Physical Count: This item displays the number of processors installed in your •
system as detected by the BIOS.
Logical Count: This item displays the number of CPU Cores installed in your
•
system as detected by the BIOS.
Micro_code Revision: This item displays the revision number of the BIOS Mi-
•
cro_code used in your system.
System Memory
This displays the size of memory available in the system:
Size: This item displays the memory size detected by the BIOS.
•
4-3
Page 64
X8DT3/X8DTi/X8DT3-LN4/X8DTi-LN4User’s Manual
4-3 Advanced Setup Confi gurations
Use the arrow keys to select Boot Setup and hit <Enter> to access the submenu
items:
BOOT Features
Quick Boot
If Enabled, this option will skip certain tests during POST to reduce the time needed
for system boot. The options are Enabled and Disabled.
Quiet Boot
This option allows the bootup screen options to be modifi ed between POST mes-
sages or the OEM logo. Select Disabled to display the POST messages. Select
Enabled to display the OEM logo instead of the normal POST messages. The options are Enabled and Disabled.
AddOn ROM Display Mode
This sets the display mode for the Option ROM. Select Keep Current to use the current AddOn ROM Display setting. Select Force BIOS to use the Option ROM display
mode set by the system BIOS. The options are Force BIOS and Keep Current.
Bootup Num-Lock
This feature selects the Power-on state for Numlock key. The options are Off
and On.
Wait For 'F1' If Error
This for ce s the sys tem to wai t until t he ' F1' key is pressed i f an er ror o cc urs . The
option s are Dis able d and Enabled.
4-4
Page 65
Chapter 4: AMI BIOS
Hit 'Del' Message Display
This feature displays "Press DEL to run Setup" during POST. The options are
Enabled and Disabled.
Interrupt 19 Capture
Interrupt 19 is the software interrupt that handles the boot disk function. When this
item is set to Enabled, the ROM BIOS of the host adaptors will "capture" Interrupt
19 at boot and allow the drives that are attached to these host adaptors to function
as bootable disks. If this item is set to Disabled, the ROM BIOS of the host adaptors will not capture Interrupt 19, and the drives attached to these adaptors will not
function as bootable devices. The options are Enabled and Disabled.
Power Confi guration
Power Button Function
If set to Instant_Off, the system will power off immediately as soon as the user hits
the power button. If set to 4_Second_Override, the system will power off when the
user presses the power button for 4 seconds or longer. The options are Instant_Off
and 4_Second_Override.
Restore on AC Power Loss
Use this feature to set the power state after a power outage.
Select Power-Off for the system power to remain off after a power loss.
•
Select Power-On for the system power to be turned on after a power loss. •
Select Last State to allow the system to resume its last state before a power •
loss. The options are Power-On, Power-Off and Last State.
Watch Dog Timer
If enable d, the Watch Dog Timer will allow the sys te m t o r e boot when it is inactive
for more t han 5 minu tes. The o ption s are Enabl ed and Disabled.
Processor and Clock Options
This submenu allows the user to confi gure the Processor and Clock settings.
C1E Support
Select Enabled to use the feature of Enhanced Halt State. C1E signifi cantly reduces
the CPU's power consumption by reducing the CPU's clock cycle and voltage during
a "Halt State." The options are Disabled and Enabled.
4-5
Page 66
X8DT3/X8DTi/X8DT3-LN4/X8DTi-LN4User’s Manual
Hardware Prefetcher (Available when supported by the CPU)
If set to Enabled, the hardware pre fetcher will pre fetch streams of data and instructions from the main memory to the L2 cache in the forward or backward manner to
improve CPU performance. The options are Disabled and Enabled.
Adjacent Cache Line Prefetch (Available when supported by the CPU)
The CPU fetches the cache line for 64 bytes if this option is set to Disabled. The
CPU fetches both cache lines for 128 bytes as comprised if Enabled.
Intel® Virtualization Technology (Available when supported by the CPU)
Select Enabled to use the feature of Virtualization T echnology to allow one platform
to run multiple operating systems and applications in independent partitions, creating mult iple " vi r tu al" sy stems i n one p hysic al c o mput er. The opti ons ar e Enabled
and Dis abled. Not e: If there is any change to this setting, you will need to power
off an d restar t the system for the change to take effect. Pleas e refer to Intel’s web
site for detailed information.
Execute-Disable Bit Capability (Available when supported by the OS and
the CPU)
Set to Enabled to enable the Execute Disable Bit which will allow the processor
to designate areas in the system memory where an application code can execute
and where it cannot, thus preventing a worm or a virus from fl ooding illegal codes
to overwhelm the processor or damage the system during an attack. The default is
Enabled. (Refer to Intel and Microsoft Web Sites for more information.)
Simultaneous Multi-Threading (Available when supported by the CPU)
Set to Enabled to use the Simultaneous Multi-Threading Technology, which will
result in increased CPU performance. The options are Disabled and Enabled.
Active Processor Cores
Set to Enabled to use a processor's Second Core and beyond. (Please refer to
Intel's web site for more information.) The options are All, 1 and 2.
Intel® Speed_Step™ Technology
EIST (Enhanced Intel SpeedStep Technology) allows the system to automatically
adjust processor voltage and core frequency in an effort to reduce power consumption and heat dissipation. Please refer to Intel’s web site for detailed information.
The options are Disable (Disable GV3) and Enable (Enable GV3).
Intel® C-STATE Tech
If enabled, C-State is set by the system automatically to either C2, C3 or C4 state.
The options are Disabled and Enabled.
4-6
Page 67
Chapter 4: AMI BIOS
Clock Spread Spectrum
Select Enable to use the feature of Clock Spectrum, which will allow the BIOS to
monitor and attempt to reduce the level of Electromagnetic Interference caused by
the components whenever needed. The options are Disabled and Enabled.
Advanced Chipset Control
The items included in the Advanced Settings submenu are listed below:
CPU Bridge Confi guration
QPI Links Speed
This feature selects QPI's data transfer speed. The options are Slow-mode, and
Full Speed.
QPI Frequency
This selects the desired QPI frequency. The options are Auto, 4.800 GT,
5.866GT, 6.400 GT.
QPI L0s and L1
This enables the QPI power state to low power. L0s and L1 are automatically
selected by the motherboard. The options are Disabled and Enabled.
Memory Frequency
This feature forces a DDR3 frequency slower than what the system has detected.
The available options are Auto, Force DDR-800, Force DDR-1066, Force DDR1333 and Force SPD.
Memory Mode
The options are Independent, Channel Mirror, Lockstep and Sparing.
Independent - All DIMMs are available to the operating system.
Channel Mirror - The motherboard maintains two identical copies of all data in
memory for redundancy.
Lockstep - The motherboard uses two areas of memory to run the same set of
operations in parallel.
Sparing - A preset threshold of correctable errors is used to trigger fail-over.
The spare memory is put online and used as active memory in place of the
failed memory.
4-7
Page 68
X8DT3/X8DTi/X8DT3-LN4/X8DTi-LN4User’s Manual
Demand Scrubbing
A memory error-correction scheme where the Processor writes corrected data
back into the memory block from where it was read by the Processor. The options are Enabled and Disabled.
Patrol Scrubbing
A memory error-correction scheme that works in the background looking for and
correcting resident errors. The options are Enabled and Disabled.
Throttling - Closed Loop/Throttling - Open Loop
Throttling improves reliability and reduces power in the processor by automatic
voltage control during processor idle states. Available options are Disabled and
Enabled. If Enabled, the following items will appear:
Hysteresis Temperature (Closed Loop Only)
Temperature Hysteresis is the temperature lag (in degrees Celsius) after the
set DIMM temperature threshold is reached before Closed Loop Throttling
begins. The options are Disabled, 1.5oC, 3.0
o
C, and 6.0oC.
Guardband Temperature (Closed Loop Only)
This is the temperature which applies to the DIMM temperature threshold.
Each step is in 0.5
o
C increment. The default is [006]. Press "+" or "-" on
your keyboard to change this value.
Inlet Temperature
This is the temperature detected at the chassis inlet. Each step is in 0.5
o
C
increment. The default is [070]. Press "+" or "-" on your keyboard to change
this value.
Temperature Rise
This is the temperature rise to the DIMM thermal zone. Each step is in
o
0.5
C increment. The default is [020]. Press "+" or "-" on your keyboard to
change this value.
Air Flow
This is the air fl ow speed to the DIMM modules. Each step is one mm/
sec. The default is [1500]. Press "+" or "-" on your keyboard to change
this value.
Altitude
This feature defi nes how many meters above or below sea level the system
is located. The options are Sea Level or Below, 1~300, 301~600, 601~900,
901~1200, 1201~1500, 1501~1800, 1801~2100, 2101~2400, 2401~2700,
2701~3000.
4-8
Page 69
Chapter 4: AMI BIOS
DIMM Pitch
This is the physical space between each DIMM module. Each step is in
1/1000 of an inch. The default is [400]. Press "+" or "-" on your keyboard
to change this value.
North Bridge Confi guration
This feature allows the user to confi gure the settings for the Intel North Bridge
chip.
Crystal Beach/DMA (Direct Memory Access)
This feature works in conjunction with the Intel I/O AT (Acceleration Technology)
to accelerate the performance of TOE devices. (Note: A TOE device is a specialized, dedicated processor that is installed on an add-on card or a network card to
handle some or all packet processing of this add-on card.) When this feature is set
to Enabled, it will enhance overall system performance by providing direct memory
access for data transferring. The options are Enabled and Disabled.
Crystal Beach/DCA (Direct Cache Access)
This feature works in conjunction with the Intel I/O AT (Acceleration Technology) to
accelerate the performance of the TOE device. When this feature set to Enabled, it
will enhance overall system performance by providing direct cache access for data
transferring. The options are Enabled and Disabled.
NUMA Support
Select Enabled to use the feature of Non-Uniform Memory Access to improve CPU
performance. The options are Enabled and Disabled.
Intel VT-d
Select Enabled to enable Intel's Virtualization Technology support for Direct I/O VT-d
by reporting the I/O device assignments to VMM through the DMAR ACPI Tables.
This feature offers fully-protected I/O resource-sharing across the Intel platforms,
providing the user with greater reliability, security and availability in networking and
data-sharing. The settings are Enabled and Disabled.
SouthBridge Confi guration
This feature allows the user to confi gure the settings for the Intel ICH South Bridge
chipset.
USB Functions
Select the number of onboard USB ports to be enabled. The Options are: Disabled,
2 USB ports, 4 USB ports, 6 USB ports, 8 Ports, 10 Ports and 12 USB ports.
4-9
Page 70
X8DT3/X8DTi/X8DT3-LN4/X8DTi-LN4User’s Manual
Legacy USB Support
Select Enabled to use Legacy USB devices. If this item is set to Auto, Legacy USB
support will be automatically enabled if a legacy USB device is installed on the
motherboard, and vise versa. The settings are Disabled, and Enabled.
USB 2.0 Controller
Select Enabled to activate the onboard USB 2.0 controller. The options are Enabled
and Disabled. (The manufacturer's default setting is Enabled. This setting cannot
be changed by the user.)
USB 2.0 Controller Mode
This setting allows you to select the USB 2.0 Controller mode. The options are
Hi-Speed (480 Mbps) and Full Speed (12 Mbps).
BIOS EHCI Hand-Off
Select Enabled to enable BIOS Enhanced Host Controller Interface support to
provide a workaround solution for an operating system that does not have EHCI
Hand-Off support. When enabled, the EHCI Interface will be changed from the BIOScontrolled to the OS-controlled. The options are Disabled and Enabled.
HDA Controller
Select Enabled to activate the onboard High-Defi nition Audio controller. The options
are Enabled and Disabled.
Reserved Page Rout
Select PCI to use PCI communication mode for the USB connections. Select LPC
to use LPC mode for the USB connections. The options are PCI and LPC.
IDE/SATA Confi guration
When this submenu is selected, the AMI BIOS automatically detects the presence
of the IDE devices and displays the following items:
SATA#1 Confi guration
If Compatible is selected, it sets SATA#1 to legacy compatibility mode, while selecting Enhanced sets SATA#1 to native SATA mode. The options are Disabled,
Compatible and Enhanced.
Confi gure SATA#1 as
This feature allows the user to select the drive type for SATA#1. Select RAID
(Intel) to enable Intel's SATA RAID fi rmware to confi gure Intel's SATA RAID
settings. Select RAID (Adaptec) to enable Adaptec's SATA RAID fi rmware to
confi gure Adaptec's SATA RAID settings. Select AHCI to enable SATA Advanced
4-10
Page 71
Chapter 4: AMI BIOS
Host Interface. (Take caution when using this function. This feature is for advanced programmers only.) The options are IDE, RAID (Intel), RAID (Adaptec)
and AHCI.
SATA#2 Confi guration
Selecting Enhanced will set SA T A#2 to native SA TA mode. The options are Disabled,
and Enhanced.
Selecting Enhanced will set SA T A#2 to native SA TA mode. The options are Disabled,
and Enhanced.
Primary IDE Master/Slave, Secondary IDE Master/Slave, Third IDE Master,
and Fourth IDE Master
These settings allow the user to set the parameters of Primary IDE Master/Slave,
Secondary IDE Master/Slave, Third and Fourth IDE Master slots. Hit <Enter> to
activate the following submenu screen for detailed options of these items. Set the
correct confi gurations accordingly. The items included in the submenu are:
Type
Select the type of device connected to the system. The options are Not Installed,
Auto, CD/DVD and ARMD.
LBA/Large Mode
LBA (Logical Block Addressing) is a method of addressing data on a disk drive.
In the LBA mode, the maximum drive capacity is 137 GB. For drive capacities
over 137 GB, your system must be equipped with a 48-bit LBA mode addressing.
If not, contact your manufacturer or install an ATA/133 IDE controller card that
supports 48-bit LBA mode. The options are Disabled and Auto.
Block (Multi-Sector Transfer)
Block Mode boosts the IDE drive performance by increasing the amount of data
transferred. Only 512 bytes of data can be transferred per interrupt if Block Mode
is not used. Block Mode allows transfers of up to 64 KB per interrupt. Select
Disabled to allow data to be transferred from and to the device one sector at
a time. Select Auto to allow data transfer from and to the device occur multiple
sectors at a time if the device supports it. The options are Auto and Disabled.
PIO Mode
The IDE PIO (Programmable I/O) Mode programs timing cycles between the
IDE drive and the programmable IDE controller. As the PIO mode increases, the
cycle time decreases. The options are Auto, 0, 1, 2, 3, and 4.
Select Auto to allow the AMI BIOS to automatically detect the PIO mode. Use
this value if the IDE disk drive support cannot be determined.
4-11
Page 72
X8DT3/X8DTi/X8DT3-LN4/X8DTi-LN4User’s Manual
Select 0 to allow the AMI BIOS to use PIO mode 0. It has a data transfer rate
of 3.3 MBs.
Select 1 to allow the AMI BIOS to use PIO mode 1. It has a data transfer rate
of 5.2 MBs.
Select 2 to allow the AMI BIOS to use PIO mode 2. It has a data transfer rate
of 8.3 MBs.
Select 3 to allow the AMI BIOS to use PIO mode 3. It has a data transfer rate
of 11.1 MBs.
Select 4 to allow the AMI BIOS to use PIO mode 4. It has a data transfer bandwidth of 32-Bits. Select Enabled to enable 32-Bit data transfer.
DMA Mode
Select Auto to allow the BIOS to automatically detect IDE DMA mode when the
IDE disk drive support cannot be determined.
Select SWDMA0 to allow the BIOS to use Single Word DMA mode 0. It has a
data transfer rate of 2.1 MBs.
Select SWDMA1 to allow the BIOS to use Single Word DMA mode 1. It has a
data transfer rate of 4.2 MBs.
Select SWDMA2 to allow the BIOS to use Single Word DMA mode 2. It has a
data transfer rate of 8.3 MBs.
Select MWDMA0 to allow the BIOS to use Multi Word DMA mode 0. It has a
data transfer rate of 4.2 MBs.
Select MWDMA1 to allow the BIOS to use Multi Word DMA mode 1. It has a
data transfer rate of 13.3 MBs.
Select MWDMA2 to allow the BIOS to use Multi-Word DMA mode 2. It has a
data transfer rate of 16.6 MBs.
Select UDMA0 to allow the BIOS to use Ultra DMA mode 0. It has a data transfer
rate of 16.6 MBs. It has the same transfer rate as PIO mode 4 and Multi Word
DMA mode 2.
Select UDMA1 to allow the BIOS to use Ultra DMA mode 1. It has a data transfer
rate of 25 MBs.
Select UDMA2 to allow the BIOS to use Ultra DMA mode 2. It has a data transfer
rate of 33.3 MBs.
Select UDMA3 to allow the BIOS to use Ultra DMA mode 3. It has a data transfer
rate of 66.6 MBs.
Select UDMA4 to allow the BIOS to use Ultra DMA mode 4. It has a data transfer
rate of 100 MBs.
4-12
Page 73
Chapter 4: AMI BIOS
Select UDMA5 to allow the BIOS to use Ultra DMA mode 5. It has a data transfer
rate of 133 MBs.
Select UDMA6 to allow the BIOS to use Ultra DMA mode 6. It has a data transfer
rate of 133 MBs. The options are Auto, SWDMAn, MWDMAn, and UDMAn.
S.M.A.R.T. For Hard disk drives
Self-Monitoring Analysis and Reporting Technology (SMART) can help predict
impending drive failures. Select Auto to allow the AMI BIOS to automatically detect hard disk drive support. Select Disabled to prevent the AMI BIOS from using
the S.M.A.R.T. Select Enabled to allow the AMI BIOS to use the S.M.A.R.T. to
support hard drive disk. The options are Disabled, Enabled, and Auto.
32Bit Data Transfer
Select Enable to enable the function of 32-bit IDE data transfer. The options are
Enabled and Disabled.
Hot Plug
Select Enable to enable the hot plug function for the SATA devices. The options
are Enabled and Disabled.
IDE Detect Timeout (sec)
Use this feature to set the time-out value for the BIOS to detect the ATA, ATAPI
devices installed in the system. The options are 0 (sec), 5, 10, 15, 20, 25, 30, and
35.
PCI/PnP Confi guration
Clear NVRAM
This feature clears the NVRAM during system boot. The options are No and Yes.
Plug & Play OS
Selecting Yes allows the OS to confi gure Plug & Play devices. (This is not required
for system boot if your system has an OS that supports Plug & Play.) Select No to
allow the AMI BIOS to confi gure all devices in the system.
PCI Latency Timer
This feature sets the latency Timer of each PCI device installed on a PCI bus. Select
64 to set the PCI latency to 64 PCI clock cycles. The options are 32, 64, 96, 128,
160, 192, 224 and 248.
4-13
Page 74
X8DT3/X8DTi/X8DT3-LN4/X8DTi-LN4User’s Manual
PCI IDE Bus Master
When enabled, the BIOS uses PCI bus mastering for reading/writing to IDE drives.
The options are Disabled and Enabled.
Slot 1 Option ROM~Slot 6 Option ROM
Select Enabled to enable Slot 1 Option ROM~Slot 6 Option ROM, which will allow
you to boot the computer from a PCI device installed on a PCI slot. The options
are Disabled and Enabled.
Select Enabled to enable the onboard LAN1/LAN2 PXE Option ROMs. This is
to boot computers using a network interface. The options are Enabled and Dis-abled.
Super IO Device Confi guration
Onboard Floppy Controller
Select Enable to enable the onboard Floppy Controller. The options are Enabled
and Disabled.
Floppy A/Floppy B
This feature allows the user to select the type of fl oppy drive connected to the sys-
tem as specifi ed. The options are Disabled, 360KB 5 1/4", 1.2MB 5 1/4", 720KB 3
1/2", 1.44MB 3 1/2" and 2.88MB 3 1/2". The default setting for Floppy A is 1.44MB
3 1/2", and for Floppy B is Disabled.
Serial Port1 Address/ Serial Port2 Address
This option specifi es the base I/O port address and the Interrupt Request address
of Serial Port 1 and Serial Port 2. Select Disabled to prevent the serial port from
accessing any system resources. When this option is set to Disabled, the serial port
physically becomes unavailable. Select 3F8/IRQ4 to allow the serial port to use 3F8
as its I/O port address and IRQ 4 for the interrupt address. The options for Serial
Port1 are Disabled, 3F8/IRQ4, 3E8/IRQ4, 2E8/IRQ3. The options for Serial Port2
are Disabled, 2F8/IRQ3, 3E8/IRQ4, and 2E8/IRQ3.
Serial Port 2 Mode
Use this feature to confi gure Serial Port 2 mode. The options are Normal, IrDA
and ASK IR. IrDA (Infrared Data) is an industry standard for remote control devices. ASK IR (Amplitude Shifted Keying Infrared) is a protocol compatible with
Sharp® branded PDAs and other infrared devices.
4-14
Page 75
Chapter 4: AMI BIOS
Watch Dog Timer
If enabled, the Watch Dog Timer will allow the system to reboot when it is inactive
for more than 5 minutes. The options are Enabled and Disabled.
Remote Access Confi guration
Remote Access
This allows the user to enable the Remote Access feature. The options are Dis-
abled and Enabled.
If Remote Access is set to Enabled, the following items will display:
Serial Port Number
This feature allows the user decide which serial port to be used for Console
Redirection. The options are COM 1, COM2, and Onboard IPMI.
Base Address, IRQ
This item displays the base address and IRQ of the serial port used for
Console Redirection.
Serial Port Mode
This feature allows the user to set the serial port mode for Console Redirection.
The options are 115200 8, n 1; 57600 8, n, 1; 38400 8, n, 1; 19200 8, n, 1; and
9600 8, n, 1.
Flow Control
This feature allows the user to set the fl ow control for Console Redirection. The
options are None, Hardware, and Software.
Redirection After BIOS POST
Select Disabled to turn off Console Redirection after Power-On Self-Test
(POST). Select Always to keep Console Redirection active all the time after
POST. (Note: This settin g may not be sup por ted by so me oper ating sys tems.)
Select Boot Loader to keep Console Redirection active during POST and Boot
Loader. The opti ons are D isabl ed, Boot L oader, and Always.
Terminal Type
This feature allows the user to select the target terminal type for Console Redirection. The options are ANSI, VT100, and VT-UTF8.
VT-UTF8 Combo Key Support
A terminal keyboard defi nition that provides a way to send commands from a
remote console. Available options are Enabled and Disabled.
4-15
Page 76
X8DT3/X8DTi/X8DT3-LN4/X8DTi-LN4User’s Manual
Sredir Memory Display Delay
This feature defi nes the length of time in seconds to display memory information.
The options are No Delay, Delay 1 Sec, Delay 2 Sec, and Delay 4 Sec.
System Health Monitor
This feature allows the user to monitor system health and review the status of each
item as displayed.
CPU Overheat Alarm
This option allows the user to select the CPU Overheat Alarm setting which determines when the CPU OH alarm will be activated to provide warning of possible
CPU overheat.
Warning!
1. Any temperature that exceeds the CPU threshold temperature pre-
defi ned by the CPU manufacturer may result in CPU overheat or system
instability. When the CPU temperature reaches this predefi ned threshold,
the CPU and system cooling fans will run at full speed.
2. To avoid possible system overheating, please be sure to provide adequate airfl ow to your system.
The options are:
The Early Alarm: Select this setting if you want the CPU overheat alarm (includ-
•
ing the LED and the buzzer) to be triggered as soon as the CPU temperature
reaches the CPU overheat threshold as predefi ned by the CPU manufacturer.
The Default Alarm
• : Select this setting if you want the CPU overheat alarm
(including the LED and the buzzer) to be triggered when the CPU temperature
reaches about 5
manufacturer to give the CPU and system fans additional time needed for CPU
and system cooling. In both the alarms above, please take immediate action
as shown below.
CPU Temperature/System Temperature
This feature displays current temperature readings for the CPU and the System.
The following items will be displayed for your reference only:
o
C above the threshold temperature as predefi ned by the CPU
CPU Temperature
The CPU thermal technology that reports absolute temperatures (Celsius/Fahrenheit) has been upgraded to a more advanced feature by Intel in its newer
processors. The basic concept is each CPU is embedded by unique temperature
4-16
Page 77
Chapter 4: AMI BIOS
information that the motherboard can read. This ‘Temperature Threshold’ or ‘Temperature Tolerance’ has been assigned at the factory and is the baseline on which
the motherboard takes action during different CPU temperature conditions (i.e., by
increasing CPU Fan speed, triggering the Overheat Alarm, etc). Since CPUs can
have different ‘Temperature Tolerances’, the installed CPU can now send information to the motherboard what its ‘Temperature Tolerance’ is, and not the other way
around. This results in better CPU thermal management.
Supermicro has leveraged this feature by assigning a temperature status to certain
thermal conditions in the processor (Low, Medium and High). This makes it easier
for the user to understand the CPU’s temperature status, rather than by just simply
seeing a temperature reading (i.e., 25
o
C). The CPU Temperature feature will display
the CPU temperature status as detected by the BIOS:
Low – This level is considered as the ‘normal’ operating state. The CPU temperature
is well below the CPU ‘Temperature T olerance’. The motherboard fans and CPU will
run normally as confi gured in the BIOS (Fan Speed Control).
User intervention: No action required.
Medium – The processor is running warmer. This is a ‘precautionary’ level and
generally means that there may be factors contributing to this condition, but the CPU
is still within its normal operating state and below the CPU ‘Temperature Tolerance’.
The motherboard fans and CPU will run normally as confi gured in the BIOS. The
fans may adjust to a faster speed depending on the Fan Speed Control settings.
User intervention: No action is required. However, consider checking the CPU fans
and the chassis ventilation for blockage.
High – The processor is running hot. This is a ‘caution’ level since the CPU’s ‘Temperature Tolerance’ has been reached (or has been exceeded) and may activate
an overheat alarm.
User intervention: If the system buzzer and Overheat LED has activated, take action
immediately by checking the system fans, chassis ventilation and room temperature
to correct any problems.
Notes: 1. The system may shut down if it continues for a long period to
prevent damage to the CPU.
2. The information provided above is for your reference only. For more
information on thermal management, please refer to Intel’s Web site at
www.Intel.com.
System Temp erature: The system temper ature wil l be displ ayed (in deg rees in
Celsiu s and Fahrenh eit) as it is detec ted by the BI OS.
This feature allows the user to decide how the system controls the speeds of the
onboard fans. The CPU temperature and the fan speed are correlative. When
the CPU on-die temperature increases, the fan speed will also increase, and vice
versa. Select Workstation if your system is used as a Workstation. Select Server if
your system is used as a Server. Select “Disabled, (Full Speed @12V)” to disable
the fan speed control function and allow the onboard fans to constantly run at the
full speed (12V). The Options are: Disabled (@full-speed), 4-pin (Server), 4-pin
(Workstation), 4-pin (Quiet) and , 4-pin (Super Quiet).
Fan1 ~ Fan 8 Reading
This feature displays the fan speed readings from fan interfaces Fan1 through Fan8.
(Fan7 is CPU1 Fan and Fan8 is CPU2 Fan.)
ACPI Confi guration
Use this feature to confi gure Advanced Confi guration and Power Interface (ACPI)
power management settings for your system.
ACPI Version Features
The options are ACPI v1.0, ACPI v2.0 and ACPI v3.0. Please refer to ACPI's website
for further explanation: http://www.acpi.info/.
ACPI APIC Support
Select Enabled to include the ACPI APIC Table Pointer in the RSDT (Root System
Description Table) pointer list. The options are Enabled and Disabled.
APIC ACPI SCI IRQ
When this item is set to Enabled, APIC ACPI SCI IRQ is supported by the system.
The options are Enabled and Disabled.
Headless Mode
This feature is used to enable system to function without a keyboard, monitor or
mouse attached The options are Enabled and Disabled.
High Performance Event Timer
Select Enabled to activate the High Performance Event Timer (HPET) that produces
periodic interrupts at a much higher frequency than a Real-time Clock (RTC) does in
synchronizing multimedia streams, providing smooth playback and reducing the de-
4-18
Page 79
Chapter 4: AMI BIOS
pendency on other timestamp calculation devices, such as an x86 RDTSC Instruction embedded in the CPU. The High Performance Event Timer is used to replace
the 8254 Programmable Interval Timer. The options are Enabled and Disabled.
Trusted Computing
TCG/TPM (Trusted Platform Module) Support
Select Yes on this item and enable the TPM jumper on the motherboard to enable
TCG (TPM 1.1/1.2)/TPM support in order to improve data integrity and network
security. The options are No and Yes.
If this feature is set to Yes, the following items will display:
TPM Enable/Disable Status
This item displays the status of TPM Enabled/Disabled state.
TPM Owner Status
This item displays the status of TPM Ownership.
IPMI Confi guration
Intelligent Platform Management Interface (IPMI) is a set of common interfaces that
IT administrators can use to monitor system health and to manage the system as a
whole. For more information on the IPMI specifi cations, please visit Intel's website
at www.intel.com.
Status of BMC
Baseboard Management Controller (BMC) manages the interface between system
management software and platform hardware. This is an informational feature which
returns the status code of the BMC micro controller.
View BMC System Event Log
This feat ur e d i sp l ays t h e BMC System Event Log (SE L). It shows the total number
of entries of BMC System Events.
To view an event, select an Entry Number and pressing <Enter> to display the
information as shown in the screen.
SEL Entry Number
•
SEL Record ID•
SEL Record Type•
4-19
Page 80
X8DT3/X8DTi/X8DT3-LN4/X8DTi-LN4User’s Manual
Timestamp•
Generator ID•
Event Message Format User•
Event Sensor Type•
Event Sensor Number,•
Event Dir Type•
Event Data.•
Clear BMC System Event Log
Clear BMC System Log
Select OK and press the <Enter> key to clear the BMC system log. Select Cancel
to keep the BMC System log. The options are OK and Cancel.
Caution: Any cleared information is unrecoverable. Make absolutely sure
that you no longer need any data stored in the log before clearing the
BMC Event Log.
Set LAN Confi guration
Set this feature to confi gure the IPMI LAN adapter with a network address as shown
in the following graphics.
Channel Number
Enter the channel number for the SET LAN Confi g command. This is initially set
to [1]. Press "+" or "-" on your keyboard to change the Channel Number.
Channel Number Status
This feature returns the channel status for the Channel Number selected above:
"Channel Number is OK" or "Wrong Channel Number".
IP Address Source
This features allows the user to select how an IP address is assigned to a client computer or network device. Select DHCP (Dynamic Host Confi guration
Protocol) to allow a client (computer or device) obtains an IP address from a
DHCP server that manages a pool of IP addresses and network information on
a "request and grant" basis. Upon time-out (or lease expiration), the IP address
assigned to the client can be reassigned to a new client. Select Static (Static
4-20
Page 81
Chapter 4: AMI BIOS
Allocation) to allow the host server to allocate an IP address based on a table
containing MAC Address/IP Address pairs that are manually entered (probably
by a network administrator). Only clients with a MAC address listed in the MAC/
IP Address Table will be assigned an IP address. The IP Address allocated to
the client is on a longer term basis than that assigned by the DHCP mentioned
in the other option. The options are DHCP and Static.
IP Address Confi guration
This submenu displays the following IP Address Confi guration information.
Parameter Selector
This item displays the parameter of your IP Address confi guration.
IP Address
This item displays the IP address of this computer. IP addresses are 6 two-digit
hexadecimal numbers (Base 16, 0 ~ 9, A, B, C, D, E, F) separated by dots. (i.e.,
00.30.48.D0.D4.60).
Current IP Address in BMC
This item displays the current IP address used for your IPMI connection.
MAC Address Confi guration
This submenu displays the following MAC Address Confi guration information.
Parameter Selector
Use this feature to select the parameter of your Mac Address confi guration.
MAC Address
This item displays the MAC address of this computer. MAC addresses are 6
two-digit hexadecimal numbers (Base 16, 0 ~ 9, A, B, C, D, E, F) separated by
dots. (i.e., 00.30.48.D0.D4.60).
Current MAC Address in BMC
This item displays the current MAC address used for your IPMI connection.
Subnet Mask Confi guration
Subnet masks tell the network which subnet this machine belongs to. The value
of each three-digit number separated by dots should not exceed 255.
Parameter Selector
Use this feature to select the parameter of your Subnet Masks confi guration.
4-21
Page 82
X8DT3/X8DTi/X8DT3-LN4/X8DTi-LN4User’s Manual
Subnet Mask
This item displays the current subnet mask setting for your IPMI connection.
VLAN Tagging
Select Enabled to enable VLAN (Virtual LAN) Tagging support which allows multiple networks to transparently share the same physical network without leaking
information between the bridged networks. VLAN Tagging complies with the IEEE
802.1Q Standards. The options are Enabled and Disabled.
SEL PEF Confi guration
PEF Confi guration
Set this feature to confi gure the Platform Event Filter (PEF). PEF interprets BMC
events and performs actions based on pre-determined settings or 'traps' under
IPMI 1.5 specifi cations. Powering the system down or sending an alert when a
triggering event is detected. The default is Disabled.
The following will appear if PEF Support is set to Enabled.
PEF Action Global Control
These are the different actions based on BMC events. The options are Alert,
Power Down, Reset System, Power Cycle, OEM Action, Diagnostic Interface.
Alert Startup Delay
This feature inserts a delay during startup for PEF alerts. The options are Enabled and Disabled.
PEF Alert Startup Delay
This sets the pre-determined time to delay PEF alerts after system power-ups
and resets. Refer to Table 24.6 of the IPMI 1.5 Specifi cation for more information
at www.intel.com. The options are No Delay, 30 sec, 60 sec, 1.5 min, 2.0 min.
Startup Delay
This feature enables or disables startup delay. The options are Enabled and
Disabled.
PEF Startup Delay
This sets the pre-determined time to delay PEF after system power-ups and
resets. Refer to Table 24.6 of the IPMI 1.5 Specifi cation for more information at
www.intel.com. The options are No Delay, 30 sec, 60 sec, 1.5 min, 2.0 min.
4-22
Page 83
Chapter 4: AMI BIOS
Event Message for PEF Action
This enables of disables Event Messages for PEF action. Refer to Table 24.6 of
the IPMI 1.5 Specifi cation for more information at www.intel.com. The options
are Disabled and Enabled.
BMC Watch Dog Timer Action
Allows the BMC to reset or power down the system if the operating system hangs
or crashes. The options are Disabled, Reset System, Power Down, Power Cycle.
BMC Watch Dog TimeOut [Min:Sec]
This option appears if BMC Watch Dog Timer Action (above) is enabled. This
is a timed delay in minutes or seconds, before a system power down or reset
after an operating system failure is detected. The options are [5 Min], [1 Min],
[30 Sec], and [10 Sec].
DMI Event Log
View Event Log
Use this option to view the System Event Log.
Mark all events as read
This option marks all events as read. The options are OK and Cancel.
Clear event log
This option clears the Event Log memory of all messages. The options are OK
and Cancel.
4-4 Security Settings
The AMI BIOS provides a Supervisor and a User password. If you use both passwords, the Supervisor password must be set fi rst.
4-23
Page 84
X8DT3/X8DTi/X8DT3-LN4/X8DTi-LN4User’s Manual
Supervisor Password
This item indicates if a Supervisor password has been entered for the system. "Not
Installed" means a Supervisor password has not been used.
User Password
This item indicates if a user password has been entered for the system. "Not I nstalle d" means that a u ser password has not been used.
Change Supervisor Password
Select this feature and press <Enter> to access the submenu, and then enter a
new Supervisor Password.
User Access Level (Available when Supervisor Password is set as above)
Use this feature to set the user's access level. The options are:
Full Access
• : grants full User read and write access to the Setup Utility,
View Only: allows access to the Setup Utility, but cannot change the fi elds,
•
Limited: allows only limited fi elds to be changed such as Date and Time, •
No Access: prevents User access to the Setup Utility.•
Change User Password
Select this feature and press <Enter> to access the submenu, and then enter a
new User Password.
Clear User Password (Available only if User Password has been set)
This item allows you to clear a user password after it has been entered.
Password Check
This item allows you to check a password after it has been entered. The options
are Setup and Always.
Boot Sector Virus Protection
When Enabled, the AMI BIOS displays a warning when any program (or virus) issues a Disk Format command or attempts to write to the boot sector of the hard
disk drive. The options are Enabled and Disabled.
4-5 Boot Confi guration
Use this feature to confi gure boot settings.
4-24
Page 85
Boot Device Priority
Chapter 4: AMI BIOS
This feature allows the user to specify the sequence of priority for the Boot Device.
The settings are 1st boot device, 2nd boot device, 3rd boot device, 4th boot device,
5th boot device and Disabled.
1st Boot Device - 1st Floppy Drive
•
2nd Boot Device - [USB: XXXXXXXXX]•
Hard Disk Drives
This feature allows the user to specify the boot sequence from all available hard
disk drives. The settings are Disabled and a list of all hard disk drives that have
been detected (i.e., 1st Drive, 2nd Drive, 3rd Drive, etc).
Removable Drives
This feature allows the user to specify the boot sequence from available Removable
Drives. The settings are 1st boot device, 2nd boot device, and Disabled.
1st Drive - 1st Floppy Drive
•
2nd Drive - [USB: XXXXXXXXX]•
CD/DVD Drives
This feature allows the user to specify the boot sequence from available CD/DVD
Drives (i.e., 1st Drive, 2nd Drive, etc).
4-25
Page 86
X8DT3/X8DTi/X8DT3-LN4/X8DTi-LN4User’s Manual
4-6 Exit Options
Select the Exit tab from the AMI BIOS Setup Utility screen to enter the Exit BIOS
Setup screen.
Save Changes and Exit
When you have completed the system confi guration changes, select this option
to leave the BIOS Setup Utility and reboot the computer, so the new system confi guration parameters can take effect. Select Save Changes and Exit from the Exit
menu and press <Enter>.
Discard Changes and Exit
Select this option to quit the BIOS Setup without making any permanent changes
to the system confi guration, and reboot the computer. Select Discard Changes and
Exit from the Exit menu and press <Enter>.
Discard Changes
Select this option and press <Enter> to discard all the changes and return to the
AMI BIOS Utility Program.
Load Optimal Defaults
To set this feature, select Load Optimal Defaults from the Exit menu and press
<Enter>. Then, select OK to allow the AMI BIOS to automatically load Optimal Defaults to the BIOS Settings. The Optimal settings are designed for maximum system
performance, but may not work best for all computer applications.
Load Fail-Safe Defaults
To set this feature, select Load Fail-Safe Defaults from the Exit menu and press
<Enter>. The Fail-Safe settings are designed for maximum system stability, but not
for maximum performance.
4-26
Page 87
Chapter 4: AMI BIOS
4-7 BIOS Recovery
Warning! Do not upgrade the BIOS unless your system has a BIOS-related
issue. Flashing the wrong BIOS can cause irreparable damage to the
system. In no event shall Supermicro be liable for direct, indirect, special,
incidental, or consequential damages arising from a BIOS update. If you
need to update the BIOS, do not shut down or reset the system while the
BIOS is updating. This is to avoid possible boot failure.
How to Recover the AMIBIOS Image (-the Main BIOS
Block)
An AMIBIOS fl ash chip consists of a boot sector block, and a main BIOS code block
(a main BIOS image). The boot sector block contains critical BIOS code, including
memory detection and recovery code to be used to fl ash a new BIOS image if the
original BIOS Image is corrupted. When the system is powered on, the boot sector
code executes fi rst. Once it is completed, the main BIOS code will continue with
system initialization and complete the bootup process.
Notes: BIOS Recovery described below is used when the main BIOS
block crashes. However, when the BIOS Boot sector crashes, you will need
to send the motherboard back to Supermicro for RMA repairs.
4.7.1 Boot Sector Recovery from a USB Device
This feature allows the user to recover a BIOS image using a USB device without
additional utilities needed. A user can download the BIOS image into a USB fl ash
device, and name the fi le "SUPER.ROM" for the recovery process to load the fi le.
A USB fl ash device such as a USB Flash Drive, a USB CDROM or a USB CDRW
device can be used for this purpose,
Insert the USB device that contains the new BIOS image (the ROM fi les) 1.
saved in a root directory into your USB drive.
While turning the power on, press and hold <Ctrl> and <Home> at the same 2.
time until the USB Access LED Indicator comes on. This might take a few
seconds.
Once the USB drive LED is on, release the <Ctrl> and <Home> keys. 3.
AMIBIOS will issue beep codes to indicate that the BIOS ROM fi le is being
updated.
When BIOS fl ashing is completed, the computer will reboot. Do not interrupt 4.
the fl ashing process until it is completed.
4-27
Page 88
X8DT3/X8DTi/X8DT3-LN4/X8DTi-LN4User’s Manual
4.7.2 Boot Sector Recovery from an IDE CD-ROM
This process is almost identical to the process of Boot Sector Recovery from a USB
device, except that the BIOS image fi le is loaded from a CD-ROM. Use a CD-R or
CD-RW drive to burn a CD with the BIOS image fi le in it, and name the fi le "SUPER.
ROM" for the recovery process to load the fi le.
4.7.3 Boot Sector Recovery from a Serial Port ("Serial
Flash")
This process, also known as "Serial Flash," allows the user to use a serial port to
load a BIOS image for Boot Sector recovery . This feature is usually used for embedded systems that rely on a serial port for remote access and debugging.
Requirements
In order to use Serial Flash for Boot Sector Recovery, you will need to meet the
following requirements.
The "Target system," the system that needs BIOS updates, must have a serial
•
port and "Serial Flash" support embedded in the BIOS image fi le.
The "Host system" should also have a serial port and a terminal program that
•
supports XModem Transfer protocol (Hyper Terminal for the Windows operating
systems, and minicom for Linux/FreeSBD, etc.).
A Null_modem serial cable
•
How to use Serial Flash for Boot Sector Recovery
Connect a Null_modem serial cable between the target system and the host 1.
system that runs the terminal program.
Make sure that the new BIOS Image fi le is accessible for the host system.2.
Start the terminal program on the host system and create a new connection. 3.
Use the following communication parameters for the new connection.
4. Power on your system and click the <Connect> button in the Hyper Terminal.
The terminal screen will display the following messages.
Press <SpaceBar> to update BIOS.
Confirm update BIOS? (y/n) y
Begin remote BIOS flash? (y/n) y
Starting remote flash.
Upload new BIOS file using Xmodem protocol.
5. Following the instructions given on the screen to update the BIOS. These
instructions are also shown below.
a. At the prompt, press the <SpaceBar> to update the BIOS.
b. When asked to confi rm BIOS updating, press <y> to confi rm BIOS
updates.
c. Press <y> again to begin fl ashing BIOS remotely.
Note: Be sure to complete Steps a~c above quickly because
you have a second or less to do so.
6. Once you've completed the instructions given, a screen will display to indicate
that remote fl ashing is starting and the new BIOS fi le is being uploaded.
7. To use Hyper Terminal to transfer the XModem protocol by using the "Send
File" dialog under the "Transfer" menu, follow the instructions below to complete XModem transfers.
a. Select the "Transfer" menu and enter <Send>.
b. Specify the location of the ROM fi le and select the proper protocol (XMo-
dem).
c. Press <Send> to start ROM File extraction. (See the picture below.)
4-29
Page 90
X8DT3/X8DTi/X8DT3-LN4/X8DTi-LN4User’s Manual
d. Once the ROM fi le extraction is completed, the message: "New BIOS re-
ceived OK" will display.
8. Once remote BIOS fl ash is completed, the system will reboot.
Note: AMIBIOS Serial Flash will work with any terminal communications
program that supports VT-100 and XModem protocols, including protocols
designed for GNU/LINUX & BSD operating systems such as minicom. It
is recommended that the terminal program be confi gured to use the 'CR/
LF' style of line termination.
4-30
Page 91
Appendix A: BIOS POST Error Codes
Appendix A
BIOS Error Beep Codes
During the POST (Power-On Self-Test) routines, which are performed each time
the system is powered on, errors may occur.
Non-fatal errors are those which, in most cases, allow the system to continue the
boot-up process. The error messages normally appear on the screen.
Fatal errors are those which will not allow the system to continue the boot-up
procedure. If a fatal error occurs, you should consult with your system manufacturer for possible repairs.
A-1 BIOS Error Beep Codes
BIOS Error Beep Codes
Beep CodeError MessageDescription
1 beepRefreshCircuits have been reset.
(Ready to power up)
5 short beeps + 1 long
beep
8 beepsDisplay memory
1 continuous beep
(with the front panel
OH LED on)
Memory errorNo memory detected in the
system
Video adapter missing or with
read/write error
System Overheat1 continuous beep with the
After all hardware components have been installed, you must fi rst confi gure Intel
South Bridge RAID Settings before you install the Windows OS and other software
drivers. T o confi gure RAID settings, please refer to RAID Confi guration User Guides
posted on our website at www.supermicro.com/support/manuals.
B-1 Installing the Windows OS to a RAID System
Insert Microsoft's Windows XP/2003/2008/Vista Setup CD in the CD Driver, 1.
and the system will start booting up from CD.
Press the <F6> key when the message-" Press F6 if you need to install a 2.
third party SCSI or RAID driver" displays.
When the Windows XP/2003/2008/Vista Setup screen appears, press "S" to 3.
specify additional device(s).
Insert the driver diskette-"ITE RAID XP/2003/2008/Vista Driver for IDE" into 4.
Drive A: and press the <Enter> key.
When the Windows OS Setup screen appears, press "S" to specify additional 5.
device(s).
Insert the driver diskette-"Intel AA RAID XP/2003/2008/Vista Driver for 6.
ICH10R" into Drive A: and press the <Enter> key.
Choose the Intel(R) ICH10R 7. SATA RAID Controller from the list indicated in
the Windows OS Setup Screen, and press the <Enter> key.
Press the <Enter> key to continue the installation process. (If you need to 8.
specify any additional devices to be installed, do it at this time.) Once all
devices are specifi ed, press the <Enter> key to continue with the installation.
From the Windows OS Setup screen, press the <Enter> key. The Windows 9.
OS Setup will automatically load all device fi les and then, continue the Win-
dows OS installation.
After the Windows OS Installation is completed, the system will automatically 10.
reboot.
B-2 Installing the Windows OS to a Non-RAID System
Insert Microsoft's Windows XP/Windows 2003/Windows 2008/Windows Vista 1.
Setup CD in the CD Driver, and the system will start booting up from CD.
Continue with the OS installation. The Windows OS Setup screen will display.2.
From the Windows OS Setup screen, press the <Enter> key. The Windows 3.
OS Setup will automatically load all device fi les and then continue with the
Windows OS installation.
After the Windows OS Installation is completed, the system will automatically 4.
reboot.
Insert the Supermicro Setup CD that came with your motherboard into the CD 5.
Drive during system boot, and the main screen will display.
B-2
Page 95
Appendix C: Software Installation Instructions
Appendix C
Software Installation Instructions
C-1 Installing Software Programs
After you've installed the Windows Operating System, a screen as shown below
will appear. You are ready to install software programs and drivers that have not
yet been installed. To install these software programs and drivers, click the icons
to the right of these items.
Notes:
1. Click the icons showing a hand writing on the paper to view the readme
fi les for each item. Click on a computer icon to the right of an item to
install an item (from top to the bottom) one at a time. After installing each
item, you must re-boot the system before proceeding with the next item
on the list. The bottom icon with a CD on it allows you to view the entire
contents of the CD.
2. When making a storage driver diskette from booting into a Driver CD,
please set the SATA Confi guration to "Compatible Mode" and confi gure
SATA as IDE in the BIOS Setup. After making the driver diskette, be sure
to change the SATA settings back to your original settings.
The Supero Doctor III program is a Web-base management tool that supports
remote management capability. It includes Remote and Local Management tools.
The local management is called the SD III Client. The Supero Doctor III program
included on the CDROM that came with your motherboard allows you to monitor
the environment and operations of your system. Supero Doctor III displays crucial
system information such as CPU temperature, system voltages and fan status. See
the Figure below for a display of the Supero Doctor III interface.
Note: 1 The default user name and password are ADMIN.
Note 2: In the Windows OS environment, the Supero Doctor III settings
take precedence over the BIOS settings. When fi rst installed, Supero Doc-
tor III adopts the temperature threshold settings previously set in BIOS. Any
subsequent changes to these thresholds must be made within Supero Doctor, since the SD III settings override the BIOS settings. For the Windows
OS to adopt the BIOS temperature threshold settings, please change the
SDIII settings to be the same as those set in BIOS.
Supero Doctor III Interface Display Screen-I (Health Information)
C-2
Page 97
Appendix C: Software Installation Instructions
Supero Doctor III Interface Display Screen-II (Remote Control)
Note: SD III Software Revision 1.0 can be downloaded from our Web
site at: f tp://ft p.superm icro.co m/utilit y/Supero _D octor_I II/. You c an also
download SDIII User's Guide at: http://www.supermicro.com/PRODUCT/
Manuals/SDIII/UserGuide.pdf. For Linux, we will still recommend that you
use Supero Doctor II.