99 Washington Street
Melrose, MA 02176
Phone 781-665-1400
Toll Free 1-800-517-8431
Visit us at www.TestEquipmentDepot.com
The Right Choice
The Right Choice
Sealed Unit Parts Co., Inc.
DPG25V
Digital Pressure Gauge
Manual
DPG25V
P/N 20437
4
05072014

Operating Instructions
The DPG25V is a microcontroller based, digital pressure
gauge that can be used with any gas, liquid or
solid that is compatible with 17-4 PH stainless steel.
The DPG transducer is a one-piece high strength stainless
steel construction that uses no silicone oil, no welds,
no o-rings or seals making it ideal for pressure
measurements of all kinds.
All functions of the DPG are controlled from 3 front panel
push buttons located below the display. Each button has a
specific function as described below.
POWER: Press and release this button to turn the
DPG ON or OFF. The DPG will automatically
turn OFF after one hour to conserve battery
power.
ZERO: Press and release this button to place the
DPG in RELATIVE PRESSURE mode.
When the button is pressed, the display will
read ZERO instead of the pressure
measurement. Subsequent display readings
will be +/- realtive to the original pressure.
UNITS: Press this button to cycle through the UNITS
of measurement the DPG25V can display.
The DPG25V can measure pressure in PSI and
InHg. This can be changed at any time and
will not affect the operation of the DPG.
ZERO SET: Over the course of time it may become
necessary to reset the DPG to zero.
This is a special function of the DPG and
can only be done at zero pressure.
Press and hold the POWER and ZERO
buttons simultaneously until the display
reads “ZERO SET”. Release both buttons
and the display will read zero pressure in the
current pressure units selected.
LOW BATTERY: The DPG will display a “B” in the upper right
corner of the display to indicate the battery
is nearly discharged and the DPG will
shortly cease operation. For best results
replace the battery immediately and use only
Alkaline or Lithium 9V batteries.
DPG25V
Product Specifications
Pressure Range -30 to 51 InHg (-14.7 to 25 PSI)
Measurement Units InHg, PSI
Resolution
PSI 0.1
InHg 0.01
Accuracy < ± 0.5% Full Scale
(includes Non-linearity,
Hysteresis and Non-repeatability)
Stability (1 year) ±0.25% Full Scale (typ)
Overange Protection 102 InHg (50 PSI)
Burst Pressure 255 InHg (125 PSI).
Pressure Cycles >100 Million
Operating Temperature Range 32°F to 130°F (0°C to 55°C)
Storage Temperature Range -40°F to 150°F (-40°C to 65°C)
Compensated Temperature Range 32°F to 130°F (0°C to 55°C)
Temperature Compensation Zero <±1.5% of Full Scale
Temperature Compensation Span <±1.5% of Full Scale
Pressure Sensor Connection 1/8” NPT Female
Update Rate 3 Samples per Second (typ)
Power 9-Volt Alkaline Battery
Automatic Power Off 1 Hour
Battery Life 100 Hours Continuous Operation (typ)
Case Material Polycarbonate
1
2
3