e LIT6P is a convenient non-
-red thermometer with probe.
It combines two precision thermometers in one
thermal penetration probe. The non-
mode can be used for quick scans of a surface
temperature, while the probe mode is used to
accurately measure internal temperatures.
Please read the following information
carefully before using the meter.
Warning: Do not point laser directly at
an eye or reflective surfaces.
nt temperature changes quickly,
allow 30 minutes for the meter to acclimate
before taking measurements
Electro-Magnetic Fields (EMF)
ing, induction furnaces, etc…
not leave the unit on or near high

Infrared measurement indication
Probe measurement indication
Infra-red:
Range: -4℉to 518℉(-20℃to270℃)
Resolution: 0.1℉/ 0.1℃
± 9℉ for -4℉ to 32℉(±5℃ for -20℃ to
±1.5% of reading +5℉(3℃) for 32℉ to 518
℉
1
2
3
4
5
6
7
6
7

(0℃ to 270℃)
Field of view: 6:1
Typical Distance to Target: up to 3 ft. (1 m)
Laser power: <1mW
Emissivity: 0.97
Over range indication: “OL” or “-OL”
Probe:
Range: -58℉ to 518℉ (-50℃ to 270℃)
Resolution:
0.2℉(0.1℃) for -58℉to 392℉ (-50℃ to
200℃)
2 ℉ (1℃) for 392℉ to 518 ℉ (200℃
℃)
Accuracy:
-58℉ to -4℉(-50℃ to -20℃): ±1.5% of rdng +2℉(1℃)
-4℉ to 392℉ (-20℃ to 200℃): ±1.0% of rdng +2℉
(1℃)
392℉ to 518℉(200℃ to 270℃): ±2.0% of rdng +7℉
(4℃)
Measurement Period: every 2 sec.
Infra-red: 32℉ to 104℉(0℃ to 40℃),10 to
Probe: 32℉ to 122 ℉(0 ℃ to 50 ℃ ) ,10
Storage environment:
14℉ to 140℉ (-10℃ to 60℃),≤75%RH
Auto power off: After 30 seconds
Weight: 4.23 oz. (120g) Approx.

-1. Infra-Red Temperature Measurement
-2. Temperature Probe Measurement
Auto power off will be disabled.
Insert the probe at least ½” (12mm)
The probe tip must be sterilized before
to avoid cross contamination.
“℃/℉” key during measurement to
switch the temperature unit
Warning: Do not point laser directly at
indirectly off reflective

ermometer has a visual angle and visual
Make sure that the target is larger than the
unit’s visual spot size. The smaller the target,
the closer you should be to it. The relationship
between distance and spot size is
The meter may be wiped down with a wet
sponge or cloth using a mild, water based
This unit is not designed for complete

submersion or washing in water.
display, it indicates that
replaced. Remove the battery cover,
eplace the exhausted batteries
Sealed Unit Parts Co., Inc. warra
repair or furnish without charge a similar product to
replace any product which, within the specified
warranty term after the date of sale by the
Wholesaler, is proved to the satisfaction of Sealed
Unit Parts Co., Inc. , to have been defec
time it was sold. Said warranty is in effect only

when said item is used in accordance with the
instructions and recommendations of Sealed Unit
This warranty applies only to products which after
shipment from the factory, have
changed, repaired, or treated in any manner
This warranty to repair or replace is the only
warranty either expressed, implied or statutory and
is the only warranty being issued herein; Sealed
Unit Parts Co., Inc.'s liability
products is expressly limited to the repair or
replacement of defective parts. All other damages
and warranties, statutory or otherwise, are being
No representative of Sealed Unit Parts Co., Inc.
change this warranty in any

manner whatsoever. No attempt to repair or
promise to repair or improve any part covered by
this warranty by any representative of this
company shall be effective unless signed by a
properly authorized officer of Sealed Unit Pa
Sealed Unit Parts Company, Inc. (SUPCO)