INSTRUCTION MANUAL
FX-7 Series
Automatic Sensitivity Stetting Fiber SensorSlim type
Never use this product as a sensing device for personnel protection.
In case of using sensing devices for personnel protection, use
products which meet standard, such as OSHA, ANSI or IEC etc.,
for personnel protection applicable in each region or country.
WARNING
Thank you very much for using SUNX products. Please read this Instruction
Manual carefully and thoroughly for the correct and optimum use of this
product. Kindly keep this manual in a convenient place for quick reference.
Item
Supply voltage
Current consumption
Sensing output
Self-diagnosis
output
External inputs
• External synchronization input
• Emission disable input
• Remote sensitivity setting input
Response time
Timer function
Ambient temperature
Material
Accessory
NPN output
FX-7 FX-75 FX-77
12 to 24V DC ± 10%, Ripple P-P 10% or less
30mA or less
NPN open-collector transistor
• Maximum sink current: 100mA
• Applied voltage: 30V DC or less
(between sensing output and 0V)
• Residual voltage:
1.0V or less (at 100mA sink current)
0.4V or less (at 16mA sink current)
Selectable either Sensing-ON or Non-sensing-ON by the ON/OFF buttons
Incorporated
ON under unstable sensing (this signal lasts approx. 40ms) or
ON when sensing output is short-circuited (signal lasts till short-circuit is rectified) (
Note 2
)
Signal condition
High ... 4.5 to 30V, or open
Low ... 0 to 1V
Input impedance: 10kΩ
0.5ms or less ( When using interference prevention function: 0.7ms or less)
Approx. 40ms fixed off-delay timer (Selectable with timer operation selection switch) (Except for FX-75, FX-75G)
–10 to +50°C (No dew condensation or icing allowed), Storage: –20 to +70°C
35 to 85% RH, Storage: 35 to 85% RH
Enclosure: Heat-resistant ABS, Enclosure cover: Polycarbonate, Fiber lock lever: PPS
MS-DIN-2 (Amplifier mounting bracket): 1 No.
PNP output
FX-7P
Standard type
External synchronization input type
Remote sensitivity setting type
Standard type
Output operation
Output operation
Short-circuit protection
Short-circuit protection
Model
No.
Ty
pe
Red LED
Green LED
FX-7G FX-75G
FX-77G
FX-7GP
Ambient humidity
Plug-in connector type is specified by suffix ‘J’ at the end of the model number. (Standard type only)
e.g.) Plug-in connector type of FX-7 is‘FX-7J’.
The remote sensitivity setting type are in the ON state for approx. 40ms even after
accepting the remote sensitivity setting input.
Notes: 1)
2)
NPN output type
PNP open-collector transistor
• Maximum source current: 100mA
• Applied voltage: 30V DC or less
(between sensing output and +V)
• Residual voltage:
2.0V or less (at 100mA source current)
1.0V or less (at 16mA source current)
PNP output type
NPN open-collector transistor
• Maximum sink current: 50mA
• Applied voltage: 30V DC or less
(between self-diagnosis output and 0V)
• Residual voltage:
1.0V or less (at 50mA sink current)
0.4V or less (at 16mA sink current)
NPN output type
PNP open-collector transistor
• Maximum source current: 50mA
• Applied voltage: 30V DC or less
(between self-diagnosis output and +V)
• Residual voltage:
2.0V or less (at 50mA source current)
1.0V or less (at 16mA source current)
PNP output type
FX7
Fiber lock lever
Stopper
Fiber cable
1
2
3
FX7
Beam-receiving part
Beam-
emitting part
Beam-receiving part
(multi-core)
Coaxial fiber
cable
Beam-emitting part (single-core)
How to mount the amplifier
Fit the rear part on the attached
amplifier mounting bracket
(MS-DIN-2) or a 35mm width DIN rail.
Press down the front part of the
amplifier on the amplifier mounting
bracket (MS-DIN-2) or the DIN rail
to fit it.
How to remove the amplifier
Push the amplifier forward.
Lift up the front part of the
amplifier to remove it.
How to connect the fiber cables
Attached amplifier mounting bracket
or 35mm width DIN rail.
FX7
1
2
1
2
Snap the fiber lock lever down.
Insert fiber cables slowly into the
inlets until they stop. (Note 1)
Lock the fiber lock lever in the
original position, till you feel a
click.
With the coaxial reflective type fiber, such as, FD-G4, FD-FM2, insert the
center fiber cable (single-core) into the beam-emitting inlet and the outer fiber
cable (multi-core) into the beam-receiving inlet. If they are inserted in reverse,
the sensing accuracy will deteriorate.
Notes: 1)
2)
In case the fiber cables are not inserted to a position where they stop, the
sensing range reduces.
Make sure to carry out the wiring in the power supply off condition.
Verify that the supply voltage variation is within the rating.
Avoid dust, dirt, and steam.
Extension up to total 100m is possible with a 0.3mm2, or more, cable.
If power is supplied from a commercial switching regulator, ensure
that the frame ground (F.G.) terminal of the power supply is connected to an actual ground.
In case noise generating equipment (switching regulator, inverter
motor, etc.) is used in the vicinity of this product, connect the frame
ground (F.G.) terminal of the equipment to an actual ground.
The self-diagnosis output is not incorporated with a short-circuit
protection circuit. Do not connect it directly to a power supply or a
capacitive load.
Do not run the wires together with high voltage lines or power lines
or put them in the same raceway. This can cause malfunction due to
induction.
Do not use during the initial transient time (0.5 sec.) after the power
supply is switched on.
Take care that the product does not come in direct contact with
water, oil, grease or organic solvents, such as, thinner, etc.