SunX FX101PZ User guide

DIGITAL FIBER SENSOR
FX-100 SERIES
Operation Guide
1 Functional Description
1-1. Functional Description 1-2. Operating Portion
2 Diagram of Functions and Settings
2-1. Diagram of Functions and Settings
3 Others
3-1. 3-2. Factory Settings 3-3. Error Display Indicator Readings
4 RUN Mode
4-1. RUN Mode 4-2. 4-3. Key Lock
.......................................................P. 3
Precautions When Selecting Settings
................................................P. 4
.........................................P. 4
Threshold Value Fine Adjustment Function
............................................P. 4
..............................P. 1
.......................P. 1
..............................P. 1
...........P. 2
.................................P. 3
INDEX
...P. 2
...P. 3
...P. 4
6 PRO Mode
6-1. PRO Mode Functions and Settings 6-2. Shift setting 6-3. External Input Setting 6-4. 6-5. GETA Function Setting 6-6. ECO Setting 6-7. Digital Display Inversion Setting 6-8. Threshold Value Margin Setting 6-9. Setting Copy 6-10. Reset
7 Quick Setting Function
8 Code Setting Function
Threshold Value Follow-up Cycle Setting
.................................................P.13
........................................P.18
.........................P.18
.......................P.20
.......................................P.21
........P.22
.........P.22
......................................P.23
...............................................P.24
...............................P.25
...............................P.26
....P.13
...P.19
5 SET Mode
5-1. SET Mode Functions and Settings 5-2. Teaching 5-3. Output Operation Setting 5-4. Timer Operation Setting 5-5. 5-6. Emission Frequency Setting
Light-emitting Amount Selection Setting
.................................................P. 5
............................................P. 7
...................P.10
.....................P.10
..............P.12
....P. 5
...P.11
1
Functional Description
1-1. Functional Description
OFF Key / Setting value DOWN key
Operation indicator (Orange)
(Lights up when the output is ON)
Digital display (Green) (Threshold value)
ON Key / Setting value UP key
MODE key
Digital display (Red) (Incident light intensity)
1-2. Operating Portion
Three keys [ (MODE key), (ON key / setting value UP key) and (OFF key / setting value DOWN key)]
are used to carry out all settings.
MODE key
ON key / Setting value UP key
OFF key / Setting value DOWN key
· Selection of setting items
· Confirmation of set contents
· RUN Mode Press for 2 sec.: To SET mode Press for 4 sec.: To PRO mode <When using the GETA function (Refer to p.20)> Press once (1 sec. or less): The incident light intensity before the GETA function is set is indicated for approx. 2 sec.
· Other than RUN mode Press for 2 sec. or more: To RUN mode or Cancel
· Selection of setting contents
· Threshold value settings in teaching mode
· Fine adjustments to the threshold value (When pressed and held, the value will change more rapidly.)
In addition, the keys can be used in combination to carry out the following.
and
· Key lock setting / release (Refer to p.4) Press simultaneously for 2 sec.
· Quick setting function (Refer to p.25) Press simultaneously for 2 sec.
· Code setting function (Refer to p.26) Press simultaneously for 4 sec.
and
1
2
Diagram of Functions and Settings
2-1. Diagram of Functions and Settings
The amplifier features and settings can be generally classified into three main modes: the ‘RUN mode’ for normal sensing operation, the ‘SET mode’ for basic settings, and the ‘PRO mode’ that contains more detailed settings.
RUN Mode QUIC CODESET ModePRO Mode
Press for 4 sec. during RUN mode.
Keep pressing until ‘ ’ is displayed.
Press for 2 sec. during RUN mode.
RUN Mode
This indicates normal sensing operation.
Threshold value fine
adjustment function
Fine adjustment of the threshold value can be done when in RUN mode.
Details: P.4
Procedure: P.4
The key lock function prevents key operations so that the conditions set in each setting mode are not inadvertently changed.
Key Lock Function
Press simultaneously for 2 sec. during RUN mode.
P. 4
Quick Setting Function
Allows various settings (output operation settings, timer operation settings, light-emitting amount selection settings and emission frequency settings) to be made in SET mode simply by selecting a setting number.
Procedure: P.4Details: P.4
Procedure: P.25Details: P.25
Settings for output operation, timer operation, light-emitting amount selection, emission frequency, ECO, external input, and shift amount are possible by selecting codes discretionary.
Keep pressing until ‘ ’ is displayed.
Code Setting Function
Press simultaneously for 4 sec. during RUN mode.
Procedure: P.26Details: P.26
SET Mode
This mode is used for carrying out basic settings.
Teaching
Threshold value can be set in 2-level teaching, limit teaching [ full-auto teaching.
, ], or
Procedure: P.7lDetails: P.5
Light-ON or Dark-ON can be set.
When fiber heads are used side-by-side, the emission frequencies for each amplifier can be set to different emission frequencies in order to prevent interference.
PRO Mode
This mode is used for carrying out detailed settings.
Shift Setting
Allows the shift amount for limit teaching [ value follow-up cycle setting to be set within the range of 0 to 80 %.
, ] and for threshold
Procedure: P.18Details: P.13
External input can be selected from emission halt, limit teaching [ teaching [ ECO.
Output Operation Setting
Procedure: P.10Details: P.5
Emission Frequency Setting
Procedure: P.12Details: P.6
External Input Setting
], limit
], full-auto teaching, and
Procedure: P.18Details: P.13l
P. 5
Timer Operation Setting
Configures timer operation and timer period.
Procedure: P.10Details: P.6
Light-emitting Amount Selection Setting
Allows light reduction to be set for the light-emitting amount. This is useful if sensing is difficult because the incident light intensity is saturated.
Procedure: P.11Details: P.6
P. 1 3
Threshold Value Follow-up Cycle Setting
Allows follow-up of the threshold value to be carried out within a set range (shift amount) in response to fluctuations in the incident light intensity.
Procedure: P.19Details: P.15
Digital Display Inversion Setting
Allows the viewing orientation of the digital display to be inverted in accordance with the setting direction of the amplifier.
Procedure: P.22Details: P.17
Threshold Value Margin Setting
Margin for threshold value to the present incident light intensity can be checked.
Procedure: P.22Details: P.17
ECO Setting
Sets the digital display to turn off in order to reduce power consumption (current consumption).
Procedure: P.21Details: P.17
Setting Copy
The settings of the master side amplifier can be copied to the slave side amplifier.
Procedure: P.23Details: P.17
2
GETA
Function
Allows the display value for the incident light intensity to be offset by the desired value (target value).
Setting
Procedure: P.20Details: P.16
Reset
Allows all settings to be returned to the factory settings.
Procedure: P.24Details: P.17
3
Others
3-1. Precautions When Selecting Settings
If (MODE key) is pressed for 2 sec. while setting is in progress in a mode other than RUN mode, the mode will switch to RUN mode. When this occurs, the settings which had been changed before (MODE key) was pressed for 2 sec. will be confirmed.
Setting protection
You can use the ‘key lock function’ to protect settings. (Refer to p.4) Key lock function can be used to prevent the operator from accidentally changing the sensor settings.
3-2. Factory Settings
Factory settings for the FX-100 series are indicated below: If the unit is reset using the ‘Reset’ from ‘PRO Mode’ on p.24, the resulting settings will be those indicated below:
SET Mode
Item
Threshold value
Output operation setting
Timer operation setting
Settings
40
Dark-ON
Without timer
Factory Setting
Digital display
Timer period setting
Light-emitting amount selection setting
Emission frequency setting
FX-101:
FX-102:
PRO Mode
Item
Shift setting
External input setting
Threshold value follow-up cycle setting
GETA function setting
ECO setting
Digital display inversion setting
Threshold value margin setting
Setting copy
Reset
ON-delay timer : 10 ms
OFF-delay timer : 10 ms
OFF
0 (Response time: 250 !s or less)
1 (Response time: 2.5 ms or less)
Factory Setting
Settings
Shift amount 15 %
Emission halt
OFF
OFF
OFF
OFF
OFF
NO
NO
*When timer is not set, this mode is not displayed.
Digital display
3-3. Error Display Indicator Readings
In case of errors, attempt the following measures:
Digital display Error description Measures
EEPROM writing error Contact our office.
The load has short-circuited and excess current is flowing.
Communication error. Disconnection, connection failure, etc.
Turn off the power, then check the load.
Turn off the power, and then check the wiring for using the setting copy function.
3
4
RUN Mode
4-1. RUN Mode
Digital display
;When turn ON the power, the Model No. is displayed in the
green digital display, and the emission frequency is displayed in
the red digital display. Then switch into RUN mode [digital
display (green: threshold value, red: incident light intensity.)]
When the power is ON
Model No.
Emission frequency
Automatic
RUN mode
Threshold value
Incident light intensity
;‘ ’ is displayed in the red digital display when emission halt
is selected in the external input setting and externally received
the signal.
When external input
For the setting of external input, refer to ‘ PRO MODE 6-3. External input setting (P.18).’
;When ECO setting mode is ON, the digital display turns off in 20 sec. approx. in
RUN mode. To light up the digital display again, press any key for 2 sec. or more.
For the setting of ECO, refer to ‘ PRO MODE 6-6. ECO setting (P.21).’
6
6
After approx. 20 sec.
Automatic Automatic
Blinks Turns off
Caution
If ‘ ’ and ‘ ’ (incident light intensity) are blinking alternately in the digital displays, check if there is a contact between the output wire (black) and the external input wire (white).
Displays blink alternately
4-2. Threshold Value Fine Adjustment Function
;Fine adjustment of the threshold value can be done when in RUN mode.
;The threshold value changes when (setting value UP key) or (setting value DOWN key) is pressed.
(when the key is pressed long, the value is accelerated.)
;The threshold value is stored after 3 sec.
When in RUN mode
Threshold value
Incident light intensity
4-3. Key Lock Function
;The key lock function prevents key operations so that the conditions set in each setting mode are not inadvertently changed.
;In the key lock condition, ‘ ’ is displayed when any key is pressed.
Key lock set
When in RUN mode
Automatic
Press and simultaneously for 2 sec.
Key lock released
When in RUN mode
Automatic Automatic
Press and simultaneously for 2 sec. or more.
(Keep pressing until ‘ ’ is displayed.)
4
5
SET Mode
5-1. SET Mode Functions and Settings
SET mode is the mode used for making basic settings. Settings for five functions can be configured.
: Teaching
Refer to p.7l for setting procedure
The ‘threshold value’ can be set by utilizing three kinds of teaching, whichever ‘2-level teaching’, ‘limit teaching [
, ]’ or ‘full-auto teaching’.
Make sure that detection may become unstable if less margin is applied in the use environment when teaching.
2-level Teaching
2-level teaching is a method of setting the threshold value by teaching the amplifier unit two different status conditions - sensing object present and sensing object absent. The ‘threshold value’ is normally set using this method.
Thru-beam type Reflective type Retroreflective type
Sensing object present
Sensing object absent
Limit Teaching [ , ]
Teaches only the status condition in which no sensing object is within sensing range (status in which incident light intensity is stable). This method is used to set a ‘threshold value’ for conducting sensing in the presence of a background, or when extremely small objects are to be detected.
Thru-beam type Reflective type Retroreflective type
P. 7
Sensing object present
P. 8 l
Sensing object absent
Sensing object present
Sensing object absent
: Output Operation Setting
Refer to p.10 for setting procedure
Minute object
Full-auto Teaching
This method is used to set the threshold value while the sensing objects are still moving on the production line, without stopping the production line.
Thru-beam type Reflective type Retroreflective type
P. 9
Background
Minute object
This mode allows the selection of output operation from either L-ON (Light-ON), or D-ON (Dark-ON). When set to ‘L-ON’, the output will be ON if the incident light intensity becomes greater than the ‘threshold value’. When set to ‘D-ON’, the output will be ON if the incident light intensity becomes less than the ‘threshold value’.
Output operation
L-ON
D-ON
04,000
Threshold value
ONOFF
OFFON
Incident light intensity
* The factory setting is ‘Dark-ON (D-ON)’.
5
: Timer Operation Setting
Refer to p.10 for setting procedure
This sets timer operation and timer period. Without timer, ON-delay timer, or OFF-delay timer can be set. In case of setting ON-delay timer or OFF-delay timer in the timer operation setting mode, timer period can be set. Select timer period from 1 ms, 5 ms, 10 ms, 20 ms, 40 ms, 50 ms, 100 ms, 500 ms, and 1,000 ms. * The factory setting is ‘Without timer’.
: Light-emitting Amount Selection Setting
Refer to p.11 for setting procedure
: Emission Frequency Setting
Refer to p.12 for setting procedure
Allows light reduction to be set for the light-emitting amount. When the setting is ON, the light-emitting amount is reduced. Use this setting if sensing is difficult because the incident light intensity is saturated (4,000 or higher). * The factory setting is ‘OFF’.
If the incident light intensity is still saturated (4,000 or higher) even when the light reduction setting is used, make the distance between the sensing objects and the fiber head longer.
When fiber heads are used side-by-side, the emission frequencies for each amplifier can be set to different frequencies in order to prevent interference. For the FX-101:, this function is activated by setting the emission frequency to 1, 2 or 3. For the FX-102:, this function is activated by setting the emission frequency to 1, 2, 3 or 4. <Number of units for interference prevention>
• Combination of FX-101: only: Maximum 3 units
• Combination of FX-102: only: Maximum 4 units
• Combination of FX-101: and FX-102:: Maximum 4 units
• For the FX-101:, the interference prevention function will not operate for
emission frequency 0 (factory setting).
• The response time will change when the emission frequency is changed.
The beam-emitting part and the operation indicator (orange) will blink while the emission frequency is being set. (They light up steadily when emission frequency 0 is set.) The blinking cycle will change depending on the emission frequency which is selected. (Refer to the table below.)
Emission frequency
FX-101:
Display
Response time
Display
FX-102:
Response time
Combination for interference prevention function to be enabled
Light-emitting operation during setting (Note)
0
1
2
3
4–
Note: The operation indicator (orange) will operate in the same way.
* The factory setting is emission frequency 0 for the FX-101: and emission frequency
1 for the FX-102:.
250 !s or less
450 !s or less 2.5 ms or less Blinks extremely quickly
500 !s or less 2.8 ms or less
600 !s or less 3.2 ms or less
None Lights up
,,
Blinks quickly
Blinks slowly
Blinks extremely slowly
5.0 ms or less
,,
,,
,,
6
5-2. Teaching
The ‘threshold value’ can be set by utilizing three kinds of teaching, whichever ‘2-level teaching’, ‘limit teaching [
,
]’ or ‘full-auto teaching’.
Make sure that detection may become unstable if less margin is applied in the use environment when teaching.
2-level Teaching
This is the method of setting the threshold value by teaching two levels, corresponding to object present and object absent conditions. Normally, setting is done by this method. The output operation setting of Light-ON or Dark-ON is reflected automatically.
For output ON when in object present condition
Press MODE key for 2 sec.
Automatic
Press ON key in object present condition.
Automatic
Press OFF key in object absent condition.
Threshold value : 2,500 Margin : 25 %
Automatic
Thru-beam type Reflective type
Sensing object present
Thru-beam type Reflective type
Sensing object absent
Sensing object present
Retroreflective type
Sensing object present
Sensing object absent
Retroreflective type
1
Press the (MODE key) for 2 sec. to select ‘SET mode’.
2
Press (ON key) in object present condition.
3
The first incident light intensity is set and indicated on the green digital display. Cancellation of the setting for the first incident light intensity is possible when (MODE key) is pressed.
4
The present incident light intensity is indicated on the red digital display with blinking.
5
Press (OFF key) in object absent condition.
6
The threshold value which is set between the first and the second
incident light intensity is indicated on the green digital display. Margin (%) for the threshold value to the first or the second incident light intensity is indicated on the red digital display. When the margin is 200 % or more, ‘ ’ is displayed.
Press MODE key for 2 sec. or 5 times.
Sensing object absent
For output ON when in object absent condition
Press MODE key for 2 sec.
Automatic
Press ON key in object absent condition.
Automatic
Press OFF key in object present condition.
Threshold value : 2,500 Margin : 25 %
Automatic
Thru-beam type Reflective type
Sensing object absent
Thru-beam type Reflective type
Sensing object present
Sensing object absent
Retroreflective type
Sensing object absent
Sensing object present
Retroreflective type
7
Press the (MODE key) 5 times or keep it pressed for
2 sec. or more, the amplifier will return to ‘RUN mode’ (normal sensing operation).
1
Press the (MODE key) for 2 sec. to select ‘SET mode’.
2
Press (ON key) in object absent condition.
3
The first incident light intensity is set and indicated on the green digital display. Cancellation of the setting for the first incident light intensity is possible when (MODE key) is pressed.
4
The present incident light intensity is indicated on the red digital display with blinking.
5
Press (OFF key) in object present condition.
6
The threshold value which is set between the first and the second
incident light intensity is indicated on the green digital display. Margin (%) for the threshold value to the first or the second incident light intensity is indicated on the red digital display. When the margin is 200 % or more, ‘ ’ is displayed.
Press MODE key for 2 sec. or 5 times.
Sensing object present
7
Press the (MODE key) 5 times or keep it pressed for
2 sec. or more, the amplifier will return to ‘RUN mode’ (normal sensing operation).
7
Limit Teaching [,]
This is the method of setting the threshold value by teaching only the object absent condition (stable incident light condition.) This is used for detection in the presence of a background body or for detection of minute objects.
When using thru-beam / retroreflective type fiber When using reflective fiber
Limit teaching [] is carried out.
<Limit teaching
Operation 1 :
Thru-beam type
operations>
[
]
Press (OFF key) in object absent condition.
Limit teaching [] is carried out.
Background
Reference incident light intensity setting)
Operation 2 :
Reflective type
Press (OFF key) once more.
Automatic threshold value setting
Retroreflective type
Shift amount
Incident light intensity
b
Incident light intensity with object absent
Threshold value
The reference incident light intensity is set in operation 1.
In operation 2, the threshold value is set to the reference incident light intensity with the shift amount
b
subtracted.
Shift amount
Incident light intensity
Threshold value
b
Incident light intensity with object absent
* Shift amount: The factory setting is ‘15 %’. For the shift amount, refer to ‘Shift Setting (P.13, P.18)’.
In case of limit teaching []
<Limit teaching
operations>
[
]
Operation 1 :
Press (ON key) in object absent condition.
Reference incident light intensity setting
Operation 2 :
Press (ON key) once more.
Automatic threshold value setting
The reference incident light intensity is set in operation 1. In operation 2, the threshold value is set to the reference incident light intensity with the shift amount
b
subtracted.
Press MODE key for 2 sec.
Automatic
Press OFF key
Automatic
Press OFF key
Automatic
Press MODE key for 2 sec. or 5 times.
Thru-beam type
Retroreflective type
Incident light intensity with object absent
Shift amount
Incident light intensity
*
The factory setting is ‘15 %’.
b
Threshold value
1
Press the (MODE key) for 2 sec. to select ‘SET mode’.
2
Press (OFF key) in object absent condition. Reference incident light intensity is set and indicated on the green digital display. The present incident light intensity is indicated on the red digital display with blinking.
Cancellation of the setting for the reference incident light intensity is possible when (MODE key) is pressed.
3
Press (OFF key) once more. The incident light intensity at this time has no relationship to the threshold value. The set threshold value is indicated on the green digital display. Margin (%) for the threshold value to the incident light intensity is indicated on the red digital display. When the margin is 200 % or more, ‘ ’ is displayed.
4
Press the (MODE key) 5 times or keep it pressed for 2 sec. or more, the amplifier will return to ‘RUN mode’ (normal sensing operation).
8
Loading...
+ 19 hidden pages