Sunvision Scientific SV101 IGUANA Hardware Installation Manual

Sunvision Scientific Inc.
SV101 IGUANA Active Surveillance
System
Hardware Installation Manual
Version 1.25
Revision History
Date Version Remark
2006/4 1.2 2006/9 1.25 PAL
2007/02/27 2.0 System requirements and setup
1
Sunvision Scientific Inc.
1 SYSTEM CONFIGURATION DIAGRAM.....................................................3
2 SYSTEM REQUIREMENTS AND SETUP....................................................4
3 SV101 COMPONENTS .........................................................................6
3.1 SV1018 IGUANA Active Surveillance module.............................8
3.2 SV1010 MPEG4 real time hardware compression video card..13
3.3 Watchdog reset cable setup......................................................17
4 SV1010 PC END CONNECTOR...........................................................18
4.1 SV1010 PC end connector Introduction....................................18
4.2 SV1010 PC Side Connector Connection...................................19
4.3 RJ45 connector PIN definition...................................................20
5 SV1015 RELAY I/O CONTROL BOARD .................................................21
6 CAMERA SETUP STEPS ......................................................................22
7 CAMERA MODULE INSTALLATION TIPS................................................26
7.1 Introduction................................................................................26
7.2 The Camera Module Installation Guidelines .............................26
7.3 Where to Install the Camera Module.........................................28
2
Sunvision Scientific Inc.
1 System Configuration Diagram
SV101 IGUANA Active Surveillance System
3
Sunvision Scientific Inc.
2 System requirements and setup
Recommended specifications of computer
z CPU z RAM z Individual VGA Card z SATA HD Control
Card
z VGA Card Slot z Hard disc z Operation System
Intel PD or Core 2 Dual (or above) 1GB or more of DDR (DDR II ) RAM AGP x 8 Interface or PCI-E x 16 Interface PCI-E Interface or PCI-X Interface
PCI Interface or PCI-X Interface 120GB x1 + 250GB or more x1 Windows XP Home Edition or Professional
z Note 1: There could be bias oblique on the preview screen when your computer
system is operated under a high load (Recording and realtime preview of 8 channels at the same time which is under the setup of 720 x 240 resolution,15 fps
or more. These conditions mean the data flow on the PCI channel was overloaded and data has been lost .It was recommanded that you DO NOT add any other PCI interface cards besides our SV1010 video compression card. Individual VGA Card and SATA HD Control Card please use other interface besides PCI, e.g. PCI-E interface or PCI-X interface.
z Note 2: Please disable the function of Hyper Threading Technology on the
CPU setup page of BIOS, or the PC will crash more often.
z Note 3: The PC system should have minimum three (3) partitions. The first
partition (C:\) is reserved for the Operation System, IGUANA software and other application software, minimum two partitions are required for IGUANA recording files. The second HD for recording should be divided into at least two partitions. If only one HD is available, it should be divided into at least three partitions.
4
Sunvision Scientific Inc.
BIOS Setup
z Note 4: It needs very high system resources to operate the SV101 Iguana
recording system. We recommended that you DO NOT install any other unnecessary applications besides the OS and SV101 recording system to avoid the recording system not working properly.
5
Sunvision Scientific Inc.
3 SV101 Components
When you receive the package of SV101, please open it and check the following items in the package.
1. SV1018 Camera Module
2. SV1018 Camera Module warranty card
3. SV1010 Package A. SV1010 warranty card B. PC side connector C. SV1010 Video Card D. Watchdog cable
4. Mounting kit
5. Screws
6. CD
6
Sunvision Scientific Inc.
SV1018Monitor
SV1010 Package
Screw Sets
CD
Mounting Kit
SV1018 Warranty Card
SV1010 Video Card
SV1010 Warranty Card
PC Side Connector
Watchdog reset cable
7
Sunvision Scientific Inc.
3.1 SV1018 IGUANA Active Surveillance module
3.1.1 Dimension of camera module and mounting kit
Method 2 Method 1
8
Sunvision Scientific Inc.
3.1.2 Camera module allocation map
9. Screws
8. IR module
5. Motor & Mirror
module
6. Wild angel camera
7. Telescopic camera
4. Terminal board
3. Motor control
circuit board
2. Power supplier
1. Upper housing
3
2
4
1
758 6 9
3.1.3 Camera Setup
3.1.3.1 Wild angle camera setup
1: BLC (Backlight Compensating function) 2: ATW/AWC (White Balance auto tracing/auto locking) 3: MIRROR (Video mirror function) 4: ZOOM (2 times digital amplification)
9
Sunvision Scientific Inc.
The function will be activated when the switch is set on the position of ON. The default is as the above figure shows. Note: The function of 2x two times digital zoom can be used in the applications where the area of interest is narrow and long. 2x digital zoom can be activated by switching SW4 to ON position. (Please refer to chapter 7, Camera Module Installation Tips.)
3.1.3.2
Telescopic camera setup
1: AES/ALC (Auto Electrical Shutter) 2: BLC (Backlight Compensation function) 3: AGC (Auto Gain Control) 4: ATW/AWB (White Balance auto tracing/auto locking) 5: MIRROR (Video mirror function) 6: ZOOM (2 times digital amplification)
10
Loading...